1 Etap Safety Manager Your emergency lighting under control: anywhere, anytime
2 Efficiently manage your emergency lighting Safety Manager () is a management system that assists you with the monitoring, configuration and maintenance of your emergency lighting. For this purpose, each device connected to your network is allocated a unique code. This allows to easily identify each luminaire and to automatically report if each luminaire is functioning properly. You can choose a wired or a wireless network, or a combination of both. With you manage not only your self-contained and central battery emergency lighting luminaires, but also any emergency units or K9 LED emergency modules that are integrated with the luminaires. You can connect your network to the internet, to have complete access from anywhere on the world wide web at any time. 2 Dashboard - Lighting - Microsoft Internet Explorer File Edit View Favorites Tools Help Back Search Favorites Standby mode Sign off James Smith Go to Links Go to Links can manage all different sorts of emergency lighting: - self-contained emergency lighting luminaires - central battery emergency lighting luminaires - lighting luminaires with K9 LED emergency module - lighting luminaires with emergency unit Notifications (1) Go to Links Confirmed notifications (0) Running duration tests (0) Go to Done Go to Done Go to Done The window colours give you immediate recognition of the status of the luminaire s functionality.
3 Internet network Central emergency supply web controller 3 EBS Advantageous in all respects You get extra safety. You save money and time by efficiently managing your emergency lighting, anywhere, anytime in line with the EN You have a multitude of options: a versatile solution for any building or system configuration. is a user friendly system. grows flexibly along with your needs. You are in good company: has for years proved its quality and stability at hundreds of companies throughout Europe.
4 You get extra safety first of all guarantees superior safety. You can see in a glance if all of your emergency luminaires are functioning properly. The software will warn you as soon as safety is no longer ensured. You can not only monitor but also actively manage your emergency lighting system from any location. You can yourself easily set the test moment, switch a maintained luminaire or start a interim test or set luminaires in rest mode. That way, you: - comply with the IEC62034 standard, which stipulates that luminaires in a single room should not be tested simultaneously. - prevent tests from being conducted at inconvenient moments - prevent all luminaires from malfunctioning simultaneously during a planned power outage, simply by setting your luminaires in rest mode. In the event that communication with the network fails, you also receive a fault message. In the meantime your emergency luminaires continue to work fully independently, including the built-in self-test. Show Logbook Code Serial number Descripton Mode Type Lamp K1_HSL004 K1_HSL005 K1_HSL Showroom 1, auditorium door Showroom 2, staircase Lobby, outside door Logbook according to EN You save time and money 4 According to European standard EN50172, you are required to regularly check all your emergency lighting systems to ensure safety in the event of a power failure. All these checks must be entered in a log book: a time-consuming activity, especially in the case of a large installation. does all this work for you by storing all required data. For each luminaire you can at all times call up the history and the current status, or print out a log with all necessary information on checks and maintenance activities. Fault messages contain all the information you need to remedy them immediately: location on a map or picture, type of luminaire, description of the defect, required spare parts. This enables you to intervene quickly and effectively at all times. Another time-saving feature. Maintenance report with detailed location information. For preventive maintenance purposes, you can retrieve detailed information about the self-contained luminaires on the number of burning hours of the lamp and the duration of the battery. Lamp Lamp code: OLFT006/011 Battery Battery code: Far-off buildings can be easily controlled and managed from any PC on the internet. You no longer need to designate an emergency lighting manager for each building. Based on the service report, you collect the necessary replacement parts for the maintenance work in advance. The complete emergency lighting system can be serviced in a single visit. Lamp: Switch off Switch settings Battery duration: 20 minutes Lamp function time: 5658 hours Last replacement: Last replacement: Register battery replacement Register lamp replacement Mode: Detailed luminaire information for efficient preventive maintenance.
5 Internet network Corporate network building management system 5 You have a multitude of options With you manage not only your self-contained and central battery luminaires, but also the emergency units that you want us to integrate with your luminaires. Self-contained emergency lighting luminaries: wireless or wired For self-contained emergency lighting within a single building, you can choose a wired or wireless solution, or a combination of both. An existing network can easily be extended with a wired or wireless network. Remote management Is your system spread over a number of buildings? In that case too, you can fully manage it from any PC. You can manage sites on all locations by the internet. You can use the local network to remotely manage your emergency lighting. The luminaires are connected via the corporate network with a com.server to the web controller. This reduces the bus wiring to a minimum. You can also connect to your building management system. Through an open interface you can give instructions to or gather information from the web controller. For a detailed representation of the status of your luminaires, you can integrate a detailed daily updated export file or make a direct connection with the web controller. Or you integrate by having a volt-free contact directly report any problems with one of your luminaires. All details are shown on your PC.
6 is a user friendly system Safety Manager is easy to install and to use. It adapts easily to the structure of your building(s), also if it is changed later. Search Sign off James Smith Easy start-up All you have to do is logically structure the luminaires in a list that reflects the structure of your building. Once your network has been set up, your software automatically detects all luminaires. An expert will help you successfully complete the start-up process. Search location Search Malle Main Building Ground Floor Auditorium 1 User friendly interface For searching a luminaire you directly navigate through the images and maps of your building. only shows the relevant information and actions that are possible in a specific context. In 2 clicks gives you the necessary information to solve a failure. The system can send a mail to preset addresses, daily or in the event of an error report. Because of the layered interface, the user friendly approach and the clear visual feedback, is easy to learn and to use. Overview - Malle, Main Building, Ground Floor, Auditorium 1 Code Serial number Description Type Mode Lamp Tests 1MB GF A AOC Auditorium1, front door 1MB GF A AOD Luminairies can easily be located on images or maps of your building. Auditorium 1, showroom door 6 grows along with your needs Flexibility in your network With your emergency lighting system can be quickly adapted or extended. In a wired network, you can interconnect the luminaires at random. To extend your installation with wireless luminaires, you can connect the interface for wireless communication (a coordinator ) anywhere in your wired network. The perfect solution when renovating buildings In the case of new buildings, you choose a wired or wireless network, depending on the acquisition and installation costs and the desired flexibility. For renovations, the installation of the communication wiring is often less feasible from a financial or aesthetic point of view. Wireless then provides the ideal solution.
7 You are in good company Our many years of experience in emergency lighting and in Safety Manager is your best guarantee for quality and stability. Over Europe, several hundred systems daily prove their worth and effectiveness. The list of companies that have chosen is too long to publish here. The following list will, however, give you an idea. As you can see, you are in good company. 7 Belgium Eurostation (Antwerp) Justitiepaleis (Brussels) Procter & Gamble (Brussels) St Jan Hospital (Bruges) France AXA (Paris) Banque de France (Paris) Hotel Auserlitz (Paris) Radio France (Paris) Portugal Autoeuropa (Lisbon) Norfin Office Park - Campus de Justiça de Lisboa (Lisbon) Túnel do Rossio (Lisbon) Laboratório Regional Veterinária e Qualidade Alimentar (Funchal) Germany Bayer AG (Leverkusen) MAN (Augsburg) Deutsche Rentenversicherung (Berlin) Continental Teves (Theinböllen) Spain Ahorro Corporación (Madrid) Coca-Cola (Madrid) TYPSA (Madrid) CESCE (Madrid) Luxembourg Luxairport (Luxembourg) Bil Dexia (Luxembourg) Ecole de Bacharage (Bacharage) the Netherlands Carré (Amsterdam) ING (Amsterdam) Schiphol (Amsterdam) TU Delft (Delft) Sweden Gränby Centrum (Uppsala) Äldreboende Ljung (Värmdö) Mobilia köpcenter (Malmö) UK Langley School (Langley) Sainsbury (London) Renfew Council (Paisley)
8 Safety Manager Efficient management over the internet Extra safety You save time and money Perfect tool to comply with EN50172 Suitable for any building configuration or system configuration Easy to expand and adjust - Easy to start up - User friendly interface - Flexibility in your network - For renovation projects and new buildings Quality and stability 09/ E/0 The information is provided for guidances only and we reserve the right to change details, as the result of technical development, without prior notice. Lighting, U.K. Branch Unit 6 Windsor Business Centre Vansittart Estate Windsor Berkshire SL4 1SE Tel. +44 (0) Fax +44 (0) [email protected]
9 (2 luminaires to repair) (1 luminaire to repair) or message Action ery error Change the battery VK1S125 and register the battery replacement via the Command menu. Send the luminaire to if the problem lasts. Date: Signature: r Change the lamp - and register the lamp replacement via the Command menu Date: Signature: Send the luminaire to E D t Application Components Advantages Safety Manager Central managing and control systems Application Program for monitoring, control, reporting and maintenance of self-contained emergency lighting systems with: - self-contained emergency lighting luminaires - Luminaires with K9 LED module - Luminaires with emergency unit* - centrally supplied luminaires connected to EBS ( Battery System) - Emergency lighting with wired or wireless communication - EBS systems and luminaires - web controller (for web TM ) or a PC with software (for windows based)** - Wired network - Optional: - Emergency Unit Gateway (EUG) for communication with lighting luminaries fitted with an emergency unit - coordinator for communication with emergency lighting luminaires equipped for wireless communication - COM server for multi-building systems connected to the local network (LAN) - Remote Access for access to the software of each PC connected to the company network - possibility of connecting an RS 232 driver (line driver) with cable for multibuilding systems not connected to a local network - volt-free contact module for transmission of errors to central control panel or building management system - - EBS coupling module for the communication with EBS via LAN or USB - Follow-up of combined systems (self-contained and centrally supplied emergency lighting systems) - Automatic logging test results and maintenance of log book in accordance with EN Low-cost precautionary maintenance through visualisation of lamp burning hours and battery duration - Field-proven system: several hundred systems installed - Control of self-contained emergency lighting luminaires via internet * for an overview of suitable types, consult ** see system function comparison, p. 9 3
10 SYSTEM FEATURES Piazza, Eindhoven - The Netherlands Luminaire - messages Software commands (individual/group/installation) Software - overview System External connections Luminaire errors: lamp, battery, electronics Network problem: communication or radio communication problem Luminaire: identification data of self-contained luminaires Remote switching of the maintained lamp (manual/periodic automatic) Adjustable test moment Search function Activate/deactivate rest mode (only for wired) Manual test function System status current operating mode (standby/test/rest/emergency), lamp status, test settings (moment/cycle), lamp burning hours (only self-contained luminaries), battery duration (luminaires via Emergency Unit Gateway and EBS systems only indicate whether the specified duration has been met) Error messages: lamp, battery, electronics, network communication error Maintenance: maintenance orders and information on luminaire, lamp and battery Statistics: status report, history System reports: installation report, test settings, status report, maintenance report (in accordance with EN 50172) Automatic export of status information (ASCII) Alarm signalling via potential free contact module Automatic fault signalling via Access via a PC with an internet or network connection web TM SYSTEM 1. emergency luminaires K1, K2, K3, K5*, K6, K7, K9*, KB, KL self-contained luminaires luminaires with K9 LED module* luminaires with emergency unit* * recessed luminaires not wireless see productpages consult 2. web controller (maximum 1 BUS per web controller) web controller Material Dimensions B x D x H Mounting Hardware aluminium 170 x 120 x 35 DIN rail 'solid state' memory / power supply: 230V, 0,7A max / Possible connections: Ethernet connector 10/100 LAN (RJ45), BUS-adapter connection web controller Licence extra luminaires Amount of luminaires: up to 100 up to 200 up to 300 up to 400 up to 500 per 50 KH KH KH KH KH KH Network a. Wired network with emergency lighting luminaires (maximum 500 luminaires per BUS) BUS-power supply BUS-adapter BUS network dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting reach: maximum distance between furthest points: 0.66 km with 0.5 mm 2 wire; 1.8 km with 1.5 mm 2 wire; 2.7 km with 2.5 mm 2 wire / resistance BUS power supply to utmost terminals: 50 Ohm / power: 3 W dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting / reach: in accordance with RS232 specifications / PC connection: RS232 COM port / power: 1 W type: 2-core twisted pair ( mm 2 ) / total length: maximum 6 km (maximum capacity: 1 µf) / topology: free K4H12 K4H16 4
11 b. Wired network for lighting luminaires with emergency units (maximum 64 luminaires per segment) EUG-power supply Emergency Unit Gateway (EUG) Wiring Emergency unit dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting / maximum reach: 200 m / power: 6 W dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting / power: 3 W type: 2-core ( mm 2 ) / total length: maximum 300 m with 1.5 mm 2 ; maximum resistance 8 Ohm luminaires with emergency unit KH7 KH6 consult BUS-segment with interior lighting with emergency unit c. Wireless network with emergency lighting luminaires Coordinator dimensions (w x h x d in mm): 160 x 130 x 60 / 2.4 GHz / 16 channels / communication based on IEEE / transmission power: 1 mw / to connect to the BUS 4. Connection with web controller KH12 wireless network with emergency lighting luminaires PC with network connection and web browser a. Direct aan de PC Network cable crossed network cable network cable b. Via corporate network CORPORATE NETWORK Corporate Network Connection to web controller via network cable c. Via Internet World Wide Web Connection to web controller via network cable WORLD WIDE WEB 5
12 windows based SYSTEM 1. self-contained emergency luminaires K1, K2, K3, K5*, K6, K9, KB K1, K2, K3, K5*, K6, K9, KB self-contained luminaires with EBS-systems: Static Dynamic Light Group luminaires with LED module luminaires with emergency unit * not wireless see productpages see productpages consult Centralised monitoring and remote control with 2. Safety Manager software Delivered on CD-ROM / assistance with set-up and start-up of the installation / protection on several password levels / integrated manual in English PC processor: minimum Pentium II MHz / OS: Windows 2000 or more recent / RAM: minimum 64 MB / HD: minimum 400 MB / video RAM: S-VGA - 1 MB / screen: VGA 640x480 / mouse / CD reader / RS232 COM port (minimum 1 ) Windows XP and 2000: login as administrator required for installation; login as main user sufficient for use 3. Network (maximum 8000 luminaires, maximum 12 COM ports per system) KH3-E a. Wired BUS network with emergency lighting luminaries (maximum 500 luminaires per BUS) BUS-power supply dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting reach: maximum distance between furthest points: 0.66 km with 0.5 mm 2 wire; 1.8 km with 1.5 mm 2 wire; 2.7 km with 2.5 mm 2 wire / resistance BUS power supply to utmost terminals: 50 Ohm / power: 3 W K4H12 BUS-adapter incl. RS232 cable 8 m dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting / reach: in accordance with RS232 specifications / PC connection: RS232 COM port / power: 1 W K4H16 BUS network -EBS coupling module via USB type: 2-core twisted pair ( mm 2 ) / total length: maximum 6 km (maximum capacity: 1 µf) / topology: free for coupling an EBS ( Battery Systems) centralised system via USB (hardware, software, user-id) KH14 -EBS coupling module via LAN for coupling an EBS centralised system via LAN (hardware, software, user-id) KH15 b. BUS segment for interior lighting with emergency units (maximum 64 luminaires per segment) BUS-segment with interior lighting with emergency unit BUS power supply Emergency Unit Gateway (EUG) Wiring Emergency unit dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting / maximum reach: 200 m / power: 6 W dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting / power: 3 W type: 2-core ( mm 2 ) / total length: maximum 300 m with 1.5 mm 2 ; maximum resistance 8 Ohm luminaires with emergency unit KH7 KH6 consult Wireless network with emergency lighting luminaires c. Wireless network with emergency lighting luminaires Coordinator dimensions (w x h x d in mm): 160 x 130 x 60 / 2.4 GHz / 16 channels / communication based on IEEE / transmission power: 1 mw / to connect to the BUS KH12 6
13 4. Connection with network in other buildings a. Via corporate network EXTRA COMPONENTS MAIN BUILDING Remote Access licence code Corporate Network 1 licence key needed per software package internal computer network KH3-RA-E CORPORATE NETWORK BUS network BUS connected via a local network (LAN) b. Via a local network (LAN) (1 PC port per LAN connection) EXTRA COMPONENTS PER ANNEX BUILDING COM-server PC and COM server driver to be configured by the local network (LAN) administrator Local Area ethernet Network (LAN) KH11 PC BUS network BUS connected via a local network (LAN) c. Via een specifieke Fixed Line over RS232 driver (line driver) (voor gebouwen niet voorzien van een LAN-verbinding) EXTRA COMPONENTS MAIN BUILDING RS232 driver depending on requirements of RS232 driver / 1 per annex building consult EXTRA COMPONENTS PER ANNEX BUILDING RS232 driver depending on requirements Wiring depending on requirements of RS232 driver (line driver) consult PC BUS network BUS connected via RS232 driver (line driver) 7
14 Technische Universiteit, Delft The Netherlands 8
15 VERSION COMPARISON VERSION COMPARISON: web TM versus windows based Search Sign off James Smith Search location Search Malle Main Building Ground Floor Auditorium 1 web TM windows based Maximum number of luminaires per system Access Local Via company network Via Internet Overview - Malle, Main Building, Ground Floor, Auditorium 1 Code Serial number Description Type Mode Lamp Tests 1MB GF A AOC Auditorium1, front door Auditorium 1, showroom door User interface Navigation with images and / or plans Navigation via tree structure Software platform Windows 2000 to Windows Vista Web browser: Explorer, Firefox, Opera or Safari Follow-up - Wired autonomous luminaires - Wireless autonomous luminaires - K9 module - Emergency units - Central battery for luminaires + EBS systems Reporting In accordance with EN50172 With web TM, luminaires can easily be located on images or maps of your building. network Direct connection to the luminaires Connection to a local network (LAN) via a COM server Connection via a landline (RS232 driver) Connection with a building management system Potential-free contact Saved daily as an export file in ASCII-format 9
16 Safety Manager (): wired / wireless 60 Coordinator KH V 50Hz overload K4H12 xmt power BUS POWER SUPPLY L N bus Communication network BUS 230V 230V 50Hz 230V 50Hz 230V 50Hz 230V 50Hz K4H16 status K4H16 status K4H16 status K4H16 status com xmt com xmt com xmt com xmt bus xmt bus xmt bus xmt bus xmt BUS ADAPTER power BUS ADAPTER power BUS ADAPTER power BUS ADAPTER power Tx Rx B Gnd PC A V+ Tx Gnd Rx V+ Tx Gnd Rx Tx Rx B Gnd PC V+ Tx Gnd Rx V+ Tx Gnd Rx V+ Tx Gnd Rx V+ Tx Gnd Rx A V+ Tx Gnd Rx V+ Tx Gnd Rx FROM COM. PORT OR PREV. ADAPTER SHORT OR TO NEXT- ADAPTER FROM COM. PORT OR PREV. ADAPTER SHORT OR TO NEXT- ADAPTER FROM COM. PORT OR PREV. ADAPTER SHORT OR TO NEXT- ADAPTER FROM COM. PORT OR PREV. ADAPTER SHORT OR TO NEXT- ADAPTER A > B MAX. 8M bus A > B MAX. 8M first bus intermediate bus last bus
Etap Safety Manager. Your emergency lighting under control: anywhere, anytime
Etap Safety Manager Your emergency lighting under control: anywhere, anytime Efficiently manage your emergency lighting Safety Manager () is a management system that assists you with the monitoring, configuration
Targus Wireless Remote Presenter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.
Targus Wireless Remote Presenter Making Your Mobile Life Easier. Visit our Web site at: www.targus.com Features and specifications are subject to change without notice. 2003 Targus Corp. 400-0110-001B
AXIS 262+ Network Video Recorder
31433/EN/R4/0803 Complete Network Video Recording Solution Complete Network Video Recording Solution Picture this: A simple and reliable, plug-and-play video surveillance system for hotels, shops, banks,
Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network
Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network Application Brief Test Challenges: Designing heating and air conditioning (HVAC) systems Collecting data on a remotely located
Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1
Table of Contents Chapter1. Introduction...1 1.1 Before Installation... 1 1.2 System Requirements... 1 Chapter2. IVS-110 1-Channel Internet Video Server...2 2.1 Package Content... 2 2.2 Physical Installation...
BabyWare Imperial PC Software
Overview (see page 1) Things You Should Know (see page 1) Getting Started (see page 2) Licenses and Registration (see page 6) Usernames Passwords and Login (see page 7) BabyWare Imperial PC Software Overview
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: 2004-07-16 Version 1.0
T-BOXN12R You can make it wireless First steps with T-BOXN12R Date: 2004-07-16 Version 1.0 Content 1. Purpose of this document... 3 2. T-BoxN12R overview... 4 3. First step... 5 3.1. Preparing your workshop
Network Projector Operation Guide
Network Projector Operation Guide Table of contents Preparation...3 Connecting the projector with your computer...3 Wired connection... 3 Wireless connection (for selective models)... 4 QPresenter...7
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
CMS Central Monitoring System
General In This Section CMS for Windows CMS Hardware CMS Functional Spec Relational Database Monitoring Interface Communication Network CMS Central Monitoring System General CMS Central Monitoring System
Targus USB Port Adapter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.
Targus USB Port Adapter Making Your Mobile Life Easier. Visit our Web site at: www.targus.com Features and specifications are subject to change without notice. 2002 Targus Corp. 400-0066-001A USER S GUIDE
Wired / Wireless / PoE. CMOS Internet Camera ICA-107 / ICA-107W / ICA-107P. Quick Installation Guide
Wired / Wireless / PoE CMOS Internet Camera ICA-107 / ICA-107W / ICA-107P Quick Installation Guide Table of Contents 1. Package Contents... 3 2. System Requirements... 4 3. Outlook... 5 Front panel of
PM1122 INT DIGITAL INTERFACE REMOTE
PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings
Before You Begin You must have at least the following: Web Browser Wired Hub/Switch/Router OR Wireless 802.11b Router CD-ROM Drive
This product can be set up using any current Web browser, i.e., Internet Explorer 6.0 or Netscape Navigator 7.0 DCS-1000W D-Link 2.4Ghz Wireless Internet Camera Before You Begin You must have at least
F453. TiF453. User guide 10/11-01 PC
F453 TiF453 User guide 10/11-01 PC 2 TiF453 User guide Contents 1. Hardware and Software requirements 4 2. Installation 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements 4 3. Fundamental
APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS
APPLICATION NOTE Contents The DMP Software Family... 1 Stand-Alone Link Software... 1 Add-on Modules for Link Software... 1 System Link End-User Panel Management Software... 2 Simple Registration and Activation...
Infinity C Reference Guide
1 2! Infinity C Reference Guide Table of Contents Components... 1 Hardware Setup... 5 SmartDrive Configuration... 12 Startup... 15 Login... 16 System Configuration... 19 DICOM Setup... 20 Monitoring Status...
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an
DIGICLIENT 8.0 Remote Agent Software
DIGICLIENT 8.0 Remote Agent Software MODEL: D17800 Series Instruction Manual English Version 1.0 Copyright 2007 Digimerge Technologies Inc Table of Contents Table of Contents About the DigiClient 8.0...
QUICK INSTALLATION GUIDE. VEBAR Battman Monitoring Software
QUICK INSTALLATION GUIDE VEBAR Battman Monitoring Software For Microsoft operating systems XP, VISTA, WINDOWS 7 For Linux OS install, please contact customer service and refer to document: VEBAR Software
SA-9600 Surface Area Software Manual
SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The
SNC-VL10P Video Network Camera
SNC-VL10P Video Network Camera CHANGING THE WAY BUSINESS 2AM. WATCHING HIS NEW PRODUCTION LINE. 10,000 MILES AWAY. COMMUNICATES www.sonybiz.net/netstation CORPORATE COMMUNICATIONS SURVEILLANCE VIDEOCONFERENCING
smart-house Web-Server Manual smart-house Web-Server Manual Version 1.03
smart-house Web-Server Manual Version 1.03 CARLO GAVAZZI HANDEL A/S, Over Hadstenvej 42, DK-8370 Hadsten, Danmark Tlf. 89 60 61 00, Fax 86 98 15 30, Reg.nr. 65 206 Internet: http://www.carlogavazzi.com/ac/dk
USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual
USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual 1 Copyright Statement No part of this publication may be reproduced in any form by any means without the prior written permission.
User Guide for Windows 10
User Guide for Windows 10 System requirements E10684 First Edition July 2015 To facilitate a smoother transition from your previous operating system, read the system requirements below before upgrading
Access control designed simply for you
TruPortal Access control designed simply for you QUICK START GUIDE Introduction TruPortal access control solutions have been engineered and designed to install quickly and easily right out of the box.
CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version 1.05.00
CX Series Video Recording Server CX784 / CX788 / CX7816 Quick Start Guide Version 1.05.00 Contents 1.Introduction...1 1.1.Packages Contents...1 1.2.Hardware Features...2 1.3.Functional Features...4 1.4.Hard
Setting Up Novell Small Business Suite
VERSION 5.1 Setting Up Novell Small Business Suite Easy to install and manage, Novell Small Business Suite 5.1 is a network software system designed to give single-site businesses superior performance
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
P-660HW-Tx v3. 802.11g Wireless ADSL2+ 4-port Gateway DEFAULT LOGIN DETAILS. Firmware v3.70 Edition 1, 2/2009
P-660HW-Tx v3 802.11g Wireless ADSL2+ 4-port Gateway Firmware v3.70 Edition 1, 2/2009 DEFAULT LOGIN DETAILS IP Address: http://192.168.1.1 Admin Password: 1234 User Password: user www.zyxel.com Copyright
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
User guide for NANOSTATION 2
User guide for NANOSTATION 2 1. Connecting hardware. Connecting your Nanostation 2 to your network is very easy, as it s using the POE (Power Over Ethernet) technology. For this you will need two direct
User Manual V1.0. Remote Software
User Manual V1.0 Notice: The information in this manual was current when published. The manufacturer reserves the right to revise and improve its products. All specifications are therefore subject to change
IXP120 Alarm Monitor Utility
IXP120 Alarm Monitor Utility SOFTWARE MANUAL Scope of Document This document provides a brief overview of the Alarm Monitor Utility and its interaction with the IXP120 Software. Document Conventions We
FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS
FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS
EasyMP Monitor Operation Guide Ver.4.40
EasyMP Monitor Operation Guide Ver.4.40 2 Notations Used in This Guide The following table shows the symbols used in this manual, along with descriptions of what they mean. Caution q s Indicates procedures
USB-2.0 Mobile Mini Hub USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.
USB-2.0 Mobile Mini Hub Making Your Mobile Life Easier. Visit our Web site at: www.targus.com Features and specifications are subject to change without notice. 2002 Targus Corp. 400-0093-001A USER S GUIDE
Quick installation guide for the Vista Quantum QNVR Network Video Recorder
QNVR range Quick Instalation guide Quick installation guide for the Vista Quantum QNVR Network Video Recorder Full manual found on the CD supplied with the NVR Contents SCOPE OF USE... 3 1. FRONT PANEL
TYLER JUNIOR COLLEGE School of Continuing Studies 1530 SSW Loop 323 Tyler, TX 75701 1.800.298.5226 www.tjc.edu/continuingstudies/mycaa
TYLER JUNIOR COLLEGE School of Continuing Studies 1530 SSW Loop 323 Tyler, TX 75701 1.800.298.5226 www.tjc.edu/continuingstudies/mycaa Education & Training Plan CompTIA N+ Specialist Program Student Full
How To Set Up A Firewall Enterprise, Multi Firewall Edition And Virtual Firewall
Quick Start Guide McAfee Firewall Enterprise, Multi-Firewall Edition model S7032 This quick start guide provides high-level instructions for setting up McAfee Firewall Enterprise, Multi-Firewall Edition
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual Section 1: Introduction SECURITY WARNING: New SEG's shipped after April 2008 will have Telnet setup option enabled by
Ethernet Radio Configuration Guide
Ethernet Radio Configuration Guide for Gateway, Endpoint, and Repeater Radio Units April 20, 2015 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com Phone 208-323-1634 FAX 208-323-1834
P-660HNU-Tx. Wireless N ADSL2+ 4-port Gateway DEFAULT LOGIN DETAILS. Firmware v1.02 Edition 1, 11/2011. IP Address: http://192.168.1.1.
P-660HNU-Tx Wireless N ADSL2+ 4-port Gateway with USB Firmware v1.02 Edition 1, 11/2011 DEFAULT LOGIN DETAILS IP Address: http://192.168.1.1 User: admin Password: 1234 www.zyxel.com Copyright 2011 ZyXEL
WUA-0605 300Mbps Wireless USB Network Adapter
WUA-0605 300Mbps Wireless USB Network Adapter User Manual V1.0 Certification FCC CE FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
Operation and Maintenance Terminal (OMT 1.2) User s Manual for use with MPW2100-23
Operation and Maintenance Terminal (OMT 1.2) User s Manual for use with MPW2100-23 1. Outline 1.1 Operation and Maintenance Terminal The OMT is powerful software when it is incorporated with the repeaters;
SecureLinx Spider Duo Quick Start Guide
SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo QUICK START GUIDE CONTENTS Overview... 2 What s In The Box... 3 Installation and Network Settings...
WRE6505. User s Guide. Quick Start Guide. Wireless AC750 Range Extender. Default Login Details. Version 1.00 Edition 1, 4 2014
WRE6505 Wireless AC750 Range Extender Version 1.00 Edition 1, 4 2014 2.4G 5G Quick Start Guide User s Guide Default Login Details LAN IP Address 192.168.1.2 User Name admin www.zyxel.com Password 1234
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
EasyMP Monitor Operation Guide Ver.4.50
EasyMP Monitor Operation Guide Ver.4.50 Notations Used in This Guide The following table shows the symbols used in this manual, along with descriptions of what they mean. Attention s Indicates procedures
EasyMP Monitor Operation Guide Ver.4.53
EasyMP Monitor Operation Guide Ver.4.53 2 Notations Used in This Guide The following table shows the symbols used in this manual, along with descriptions of what they mean. q s Indicates additional information
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
LOREX CLIENT 2.2 Integrated Remote Agent Software
LOREX CLIENT 2.2 Integrated Remote Agent Software Instruction Manual English Version 1.0 MODEL: L15LD420 / L17LD420 Series Copyright 2008 LOREX Technology Inc. www.lorexcctv.com Table of Contents Table
Westell VERSALINK GATEWAY (MODEL 327W) Quick Start Guide. 030-300391 Rev. A May 2004
Westell VERSALINK GATEWAY (MODEL 327W) Quick Start Guide Westell, Inc. Quick Start Guide 2 Congratulations! You are on your way to experiencing the Internet with DSL at speeds significantly faster than
SOFTWARE INSTALLATION INSTRUCTIONS
AUDITGARD LGA Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS Implementation Package The AuditGard Software implementation package includes: 707013 AuditGard Software Install CD 42145 Programming/Audit
VENTIsupport Version 1
Description and Operating Instructions VENTIsupport Version 1 Compliance and titration software Content 1. Description.............................2 1.1 Purpose............................2 1.2 Labelling............................2
Fiery E100 Color Server. Welcome
Fiery E100 Color Server Welcome 2011 Electronics For Imaging, Inc. The information in this publication is covered under Legal Notices for this product. 45098226 27 June 2011 WELCOME 3 WELCOME This Welcome
Version 1.00. User Manual. USB 3.0 to Gigabit Ethernet Adapter DUB-1312
Version 1.00 User Manual USB 3.0 to Gigabit Ethernet Adapter DUB-1312 Manual Overview D-Link reserves the right to revise this publication and to make changes in the content hereof without obligation to
TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module
Panduit Corp. 2010 TDP43ME NetPS PA26306A01 Rev. 01 11-2010 Network Printer Server Control Center for Ethernet Module NOTE: In the interest of higher quality and value, Panduit products are continually
User Guide HUAWEI UML397. Welcome to HUAWEI
User Guide HUAWEI UML397 Welcome to HUAWEI 1 Huawei UML397 4G LTE Wireless Modem User Manual CHAPTER 1 BEFORE USING YOUR UML397 WIRELESS MODEM ABOUT THIS USER MANUAL...4 WHAT S INSIDE THE PRODUCT PACKAGE...4
Quick Installation Guide DSL-2640U. Wireless N 150 ADSL2+ Modem Router
DSL-2640U Wireless N 150 ADSL2+ Modem Router BEFORE YOU BEGIN Delivery Package Wireless router DSL-2640U Power adapter DC 12V/0.5A RJ-11 telephone cable Straight-through Ethernet cable (CAT 5E) Splitter
R60 USB to CAN interface Manual (1.5 EN)
R60 USB to CAN interface Manual (1.5 EN) General information R60 USB to CAN interface Manual Version 1.5 EN, 02/2010, DOC01586 Copyright 2010 by ; all rights reserved. Eugen-Adolff-Strasse 134, D-71522
EW7031/EW7032-2,5 SATA/eSATA Hard Disk Enclosure
2 ENGLISH EW7031/EW7032-2,5 SATA/eSATA Hard Disk Enclosure Warnings and points of attention Opening of the product and/or products can lead to severe injuries! Repairing of the product should be done by
TrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
TMA Management Suite. For EAD and TDM products. ABOUT OneAccess. Value-Adding Software Licenses TMA
For EAD and TDM products Value-Adding Software Licenses ABOUT OneAccess OneAccess designs and develops a range of world-class multiservice routers for over 125 global service provider customers including
WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address
Instructions Page 1 Connections The WxGoos-1 is a self-contained web server and requires 6vdc of power at 300ma. A center-positive 2.1 mm plug is used. There are five ports: 1. 10/100 Ethernet RJ-45 receptacle
How To Use An Easymp Network Projector On A Computer Or Network Projection On A Network Or Network On A Pc Or Mac Or Ipnet On A Laptop Or Ipro Or Ipo On A Powerbook On A Microsoft Computer On A Mini
EasyMP Network Projection Operation Guide Contents 2 Before Use Functions of EasyMP Network Projection....................... 5 Sharing the Projector....................................................
Cisco 831 Router and Cisco SOHO 91 Router Cabling and Setup Quick Start Guide
English CHAPTER 1 Cisco 831 Router and Cisco SOHO 91 Router Cabling and Setup Quick Start Guide Cisco One-Year Limited Hardware Warranty Terms Easy Installation: Try These Steps First! (CRWS Users) Overview
Substation Monitoring System SMS 510. Product Guide
1MRS751973_MBG Issued: 19.10.2000 Status: Updated Version: D/07.02.2006 Data subject to change without notice Features Local and remote workplace Automatic dial-up of substations Automatic or manual collection
AXIS 211A Network Camera
PRODUCT REVIEW GUIDE TABLE OF CONTENTS 1 PRODUCT BRIEF... 3 2 REQUIREMENTS FOR TEST... 4 3 INSTALLATION... 5 3.1 Installing the AXIS 211A... 5 3.2 Set the IP address with AXIS IP Utility... 5 3.2.1 Automatic
Wireless Internet Camera
Wireless Internet Camera Wireless G Mobile USB 2.0 Adapter with 3G Video Minimum System Requirements PC with: Windows XP/2000 1GHz processor Memory Size: 512MB 100MB of available hard drive space and a
2100 POS System. 2100 User Guide
2100 POS System 2100 User Guide Thank you for selecting UTC RETAIL s innovative Model 2100 Point of Sale solution! This guide is designed to acquaint you with the features and functionality of the 2100
RS-232/422/485, Power over Ethernet
IP-COM-M IP-COMi-M IP-COM-M PoE IP-COMi-M PoE RS-232 RS-232/422/485 RS-232, Power over Ethernet RS-232/422/485, Power over Ethernet Edition: September 2012 The computer programs provided with the hardware
VTO6xxx. IP door stations. User manual
VTO6xxx IP door stations User manual Table of Contents 1 Product Appearance 2 Basic Function Introduction 2.1 Call Manager Center 2.2 Call User 2.2.1 Connecting Status 2.2.2 Calling Status 2.3 Monitor
8/16-Port IP KVM Switch IKVM-8010 / IKVM-16010. Quick Installation Guide
8/16-Port IP KVM Switch IKVM-8010 / IKVM-16010 Quick Installation Guide Table Of Contents Chapter 1 Introduction... 3 1.1 Features... 3 1.2 Package Contents... 4 1.3 Technical Specifications... 4 Chapter
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
SB-2000 USB Radio Interface Operating Manual CG Antenna Co. Ltd.
CG Antenna SB-2000 USB Radio Interface Operating Manual CG Antenna Co. Ltd. Shanghai, China FEATURES Connect your computer with USB port. No need serial or parallel port. Most of Radio programs are built
Network Camera. Quick Operation Guide V4.0.1
Network Camera Quick Operation Guide V4.0.1 Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to DS-2CD8253F-EI(Z),
Guide for wireless environments
Sanako Study Guide for wireless environments 1 Contents Sanako Study... 1 Guide for wireless environments... 1 What will you find in this guide?... 3 General... 3 Disclaimer... 3 Requirements in brief...
Chapter 5 Cubix XP4 Blade Server
Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel
Emerson Smart Firewall
DeltaV TM Distributed Control System Product Data Sheet Emerson Smart Firewall The Emerson Smart Firewall protects the DeltaV system with an easy to use perimeter defense solution. Purpose built for easy
Setup guide. point to point wall plate extenders
SDS-1002/3 point to point wall plate extenders Setup guide For more information visit our website, or talk to one of our technical team tel: +44 (0) 1306 628264 www.smart-e.co.uk SDS-1002 & 1003 SETUP
1 DVR 670 Series firmware version 2.1.2 (date 2014-06-17)
Video Recorder 670 Series 1 DVR 670 Series firmware version 2.1.2 (date 2014-06-17) File name: 600rtseries_2.1.2_140617.bin - When a unit detects a HDD error, the DVR will automatically reboot so that
Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected
Niagara Security Overview Niagara Security by Tridium, is an open, web-based security management solution that allows you to manage and monitor your facility anytime, anywhere. Built on Tridium s Niagara
Installing an Omnicast System Omnicast version 3.5
Installing an Omnicast System Omnicast version 3.5 INST-9001 Version 1.0 INST-9001 Page 1 Omnicast Install Table of Contents 1 PREAMBLE...3 1.1 DOCUMENT REVISIONS...3 1.2 OMNICAST OVERVIEW...3 1.3 SUPPORTED
Connecting to the Internet
Connecting to the Internet Connecting the Gateway to the Internet Configuration of TCP/IP Protocol Installing the USB Drivers Connecting Ethernet Network Devices Connecting USB Network Devices Connecting
Features Reference. About Unified Communication System. Before Using This Machine. Starting a Meeting. What You Can Do During the Meeting
Features Reference About Unified Communication System Before Using This Machine Starting a Meeting What You Can Do During the Meeting Leaving a Meeting Managing Address Book Changing Network Configuration
NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.
INLINE 5 Software INSTALL BULLETIN Page 2: Installing INLINE 5 Page 6: Removing INLINE 5 NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT. IMPROPER INSTALLATION OR USE CAN
Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide
Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide Document Number: P0874391 Document Release: Standard 1.00 Date: November 1997 Year Publish FCC TM 1997 All rights reserved Printed in
Amcrest 960H DVR Quick Start Guide
Amcrest 960H DVR Quick Start Guide Welcome Thank you for purchasing our Amcrest 960H DVR! This quick start guide will help you become familiar with our DVR in a very short time. Before installation and
Wireless LAN 802.11g USB Adapter
Wireless LAN 802.11g USB Adapter User s Guide Version 1.0 User s Guide 0 Copyright statement No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS
COMBOGARDPRO 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS IMPLEMENTATION PACKAGE The ComboGard Pro Software implementation package includes: 707012 ComboGard Pro Software Install
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
User manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION
Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION The Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier is a multi-functional compact device. It
P-660HWP-Dx. Quick Start Guide. 802.11g HomePlug AV ADSL2+ Gateway. Version 3.40 7/2007 Edition 1. Copyright 2007. All rights reserved.
P-660HWP-Dx 802.11g HomePlug AV ADSL2+ Gateway Quick Start Guide Version 3.40 7/2007 Edition 1 Copyright 2007. All rights reserved. Overview The P-660HWP-Dx is a gateway which combines high-speed ADSL
How To Use An Easymp Network Projection Software On A Projector On A Computer Or Computer
EasyMP Network Projection Operation Guide Contents 2 Before Use Functions of EasyMP Network Projection....................... 5 Sharing the Projector....................................................