SK 3209.XXX SK 3210.XXX
|
|
|
- Dortha Conley
- 9 years ago
- Views:
Transcription
1 Luft/Wasser-Wärmetauscher Air/water heat exchangers Echangeurs thermiques air/eau Lucht/water-warmtewisselaars Luft/vatten värmeväxlare Scambiatori di claore aria/acqua Intercambiadores de calor aire/agua SK 3209.XXX SK 3210.XXX Montage-, Installations- und Bedienungsanleitung Assembly and operating instructions Notice d emploi, d installation et de montage Montage- en bedieningshandleiding Montage- och hanteringsanvisning Istruzioni di montaggio e funzionamento Instrucciones de montaje y funcionamiento
2 Contents 1 Notes on documentation Associated documents CE labelling Retention of documents Symbols used Safety notes Device description Functional description How it works Control Bus mode (Comfort controller only) Safety equipment Condensation Leak detection Door limit switch (for units with Comfort controller only) Additional interface X3 (Comfort controller only) Proper use Scope of supply Assembly and connection Choosing the installation site Assembly instructions General Layout of the components in the enclosure Assembling the air/water heat exchanger Preparing the mounting cut-out Assembling the air/water heat exchanger Connecting the condensate discharge Connecting the water connection Connection on the side of the unit Connection on the rear of the unit Notes on water quality Notes on electrical installation Connection data Overvoltage protection and supply line load Door limit switch (for units with Comfort controller only) Potential equalisation Carrying out the electrical installation Bus connection (only when interconnecting several units with a Comfort controller) Installing the power supply Commissioning Operation Control using the Basic controller Display and system analysis Properties General programming information Operation of the Basic controller Setting the temperature Setting of system messages Programming and control of the Basic controller Reset of r6 and r7 (min./max. internal temperature) System message contact (; floating) Programming overview of Basic controller Control using the Comfort controller Properties Launching test mode General programming information Eco-mode Editable parameters Programming overview Defining system messages for evaluation Setting the Master-slave identifier Evaluating system messages Inspection and maintenance General Emptying, storage and disposal Technical specifications List of spare parts Further technical information Hydrological data Characteristic curves Water resistance Appendix 1: Cut-out and hole sizes Dimensions for assembly Appendix 2: Preparation and maintenance of the water in recooling systems Rittal air/water heat exchanger assembly and operating instructions
3 1 Notes on documentation These assembly instructions are aimed at tradespersons who are familiar with assembly and installation of the air/water heat exchanger, and at trained specialists who are familiar with the operation of the air/water heat exchanger. 1.1 Associated documents There are two sets of instructions for the unit types described here: Assembly and installation instructions enclosed with the unit in the form of a paper document. Assembly, installation and operating instructions enclosed with the unit in the form of a PDF file (Adobe Acrobat) on CD-ROM. We cannot accept any liability for damage associated with failure to observe these instructions. Where applicable, the instructions for any accessories used also apply. 1.2 CE labelling The declaration of conformity is supplied with the unit as a separate document. 1.3 Retention of documents These instructions and all associated documents constitute an integral part of the product. They must be given to the plant operator. The plant operator is responsible for storage of the documents so they are readily available when needed. 1.4 Symbols used Please observe the following safety instructions and other notes in this guide: Symbol identifying required actions: The bullet point indicates an action to be performed. Safety and other notes: 1 Notes on documentation 2 Safety notes Please observe the following general safety notes when assembling and operating the unit: Assembly, installation and servicing may only be performed by properly trained specialists. The minimum water inlet temperature of +1 C must not be reduced at any point in the water cycle. Otherwise there is danger of frost damage! Use antifreeze agents only with the manufacturer s consent. Do not obstruct the air inlet and air outlet of the air/water heat exchanger inside the enclosure (see also section 4.2.2). The heat loss of the components installed in the enclosure must not exceed the specific useful cooling output of the air/water heat exchanger. The air/water heat exchanger must always be transported in a vertical position. Use only original spare parts and accessories. Do not make any changes to the air/water heat exchanger other than those described in these instructions or associated instructions. The mains connector of the air/water heat exchanger must only be connected and disconnected with the system de-energised. Connect the pre-fuse specified on the rating plate. Danger! Immediate danger to life and limb! Caution! Potential threat to the product and its environment. Note: Useful information and special features. Rittal air/water heat exchanger assembly and operating instructions 3
4 3 Device description 3 Device description Depending on the model chosen, your air/water heat exchanger may vary in appearance from the illustrations contained in these instructions. However, the functions are identical in principle How it works The air/water heat exchanger comprises three main components (cf. fig. 2): Heat exchanger package (1), fan (2) and the magnetic valve (3) connected with each other using pipes. Fan (2) 1 Heat exchanger (1) Temperature control 2 3 Non-return valve Magnetic valve (3) 4, 5, 6 7 Cooling water return Cooling water inlet Fig. 1: Device description 9 10 Key 1 Cover 2 Rating plate 3 Display 4 X2 master/slave connection (Comfort controller) 5 X1 terminal strip (underside of the unit) 6 X3 optional serial interface (underside of the unit) 7 Dispatch bag 8 Cooling water inlet 9 Cooling water return 10 Condensate discharge 8 Fig. 2: Air/water heat exchanger The heat loss of the enclosure is dissipated in a membrane heat exchanger to the water coolant. A fan (2) blows the internal enclosure air over the heat exchanger (1); except for the inlet and outlet water and the condensed water discharge, the unit is closed to the environment. The flow regulator (3) controls the cooling output by changing the water flow volume depending on the required housing temperature and the water inlet temperature Control Rittal enclosure air/water heat exchangers are fitted with a controller for setting the functions of the heat exchanger. Depending on the design, this is either a Basic controller (temperature display via LED) or a Comfort controller (display plus extended functions, see chapter 6 Operation, page 15). 3.1 Functional description Air/water heat exchangers are designed and built to dissipate heat from enclosures by cooling the air inside the enclosure and so protect the temperaturesensitive components. Air/water heat exchangers are particularly appropriate for the temperature range of up to +70 C where comparable units, such as air/air heat exchangers, enclosure cooling units or fan-and-filter units, cannot be used for system reasons to effectively and economically dissipate heat loss. It is mounted on the roof of an enclosure. 4 Rittal air/water heat exchanger assembly and operating instructions
5 3.1.3 Bus mode (Comfort controller only) The serial unit interface X2 allows you to create a bus connection with up to ten air/water heat exchangers using the master/slave cable (shielded, four-wire cable, Model No. SK ). This allows you to implement the following functions: Parallel unit control (the air/water heat exchangers in the network can be switched on and off simultaneously) Parallel door status message ( door open ) Parallel collective fault message Data is exchanged via the master-slave connection. During commissioning, assign an address to each unit that also includes the identifier master or slave Safety equipment To protect against overcurrent and overtemperature, the fan is equipped with a thermal winding protection. The unit has one (in the case of the Basic controller) or two (in the case of the Comfort controller) integral floating contacts on the connection terminal (system message relay with change-over contact, terminal 3 5) which may be used to retrieve messages from the heat exchanger, e.g. via PLC. Units with Basic and Comfort controllers are also equipped with a condensate alarm Condensation At high levels of humidity and low cooling water temperatures inside the enclosure, condensation may form on the heat exchanger. Any condensation that forms on the heat exchanger (with high humidity and low water temperatures) is routed to the right and/or rear out of the unit via a drain opening in the plastic tray. For this purpose, a hose must be connected to one of the two condensate nozzles (see 4.4 Connecting the condensate discharge, page 8). The drain which is not required should be tightly sealed. The condensate must be able to run off freely. The hose used for draining off condensate must be laid free from kinks and checked for correct drainage. Units with Basic and Comfort controllers are also equipped with a condensate alarm. Condensate hoses are available as accessories (refer also to the accessories section in the Rittal Catalogue) Leak detection If a leakage or pipe breakage occurs in the water circuit of the air/water heat exchanger, a magnetic valve immediately stops the cooling water supply and the floating change-over contact is activated. In the case of a unit with Comfort controller, the fan is also switched off. 3 Device description Basic controller: The system message IA appears in the display. Comfort controller: The system message A08 appears in the display Door limit switch (for units with Comfort controller only) Air/water heat exchangers with Comfort controller may be operated with a door limit switch connected. The door limit switch is not included with the supply (available as an accessory, Model No. PS ). The door limit switch function causes the fan and the magnetic valve in the air/water heat exchanger to be switched off after approximately 15 seconds when the enclosure door is opened (contacts 1 and 2 closed). This prevents the formation of condensation inside the enclosure while the enclosure door is open. The fan will start up after about 15 seconds on closure of the door. The connection is made at terminals 1 and 2. The extra-low voltage is supplied by the internal power pack; the current is approx. 30 ma DC. Note: The door limit switches must only be connected free from potential. No external voltages! Additional interface X3 (Comfort controller only) Note: The electrical signals at the interface are of an extra-low voltage (not extra-low safety voltages to ). An additional interface card may be connected to the 9-pole SUB-D connector X3 in order to incorporate the air/water heat exchanger into higher-level monitoring systems (available as an accessory, interface card Model No. SK ). 3.2 Proper use Rittal enclosure air/water heat exchangers were developed and designed in accordance with the state of the art and the recognised rules governing technical safety. Nevertheless, if used improperly, they may pose a threat to life and limb or cause damage to property. The unit is only intended for cooling enclosures. Any other use is deemed improper. The manufacturer will not be liable for any damages caused as a result of improper use, or for incorrect assembly, installation or use. All risk is borne solely by the user. Proper usage also includes the observation of all valid documents and compliance with the inspection and servicing conditions. Rittal air/water heat exchanger assembly and operating instructions 5
6 4 Assembly and connection 3.3 Scope of supply The unit is supplied in a packaging unit in a fully assembled state. Please check the scope of supply for completeness. Qty. Designation 1 Air/water heat exchanger Tab. 1: Dispatch bag: Plug-in terminal strip Sealing frame Assembly and installation instructions Assembly, installation and operating instructions on CD-ROM Declaration of conformity Hose sleeves 1 Drilling template Supply of supply 4 Assembly and connection 4.1 Choosing the installation site When choosing the installation site for the enclosure, please observe the following: The air/water heat exchanger must be installed and operated in a vertical position. The ambient temperature must not exceed +70 C. It must be possible to fit a condensate discharge (see 4.4 Connecting the condensate discharge, page 8). It must be possible to fit a cooling water supply and return (see 4.5 Connecting the water connection, page 9). The mains connection data as stated on the rating plate of the unit must be guaranteed. 4.2 Assembly instructions General Check the packaging carefully for signs of damage. Any packaging damage may be the cause of a subsequent functional failure. The enclosure must be sealed on all sides (IP 54). Increased condensation will occur if the enclosure is not airtight. The air inlet and outlet must not be obstructed on the inside of the enclosure. In order to avoid excessive condensation inside the enclosure, we recommend installing a door limit switch (e.g. PS ) which deactivates the air/water heat exchanger when the enclosure door is opened (see Door limit switch (for units with Comfort controller only), page 5). 6 Rittal air/water heat exchanger assembly and operating instructions
7 4.2.2 Layout of the components in the enclosure Caution! Risk of condensation! When arranging the components inside the enclosure, please ensure that the cold airflow from the air/water heat exchanger is not directed at active components. Please also ensure that the cold airflow is not directed at the warm exhaust airflow from active components such as converters. This may lead to an air short-circuit and therefore prevent adequate climate control, or may even cause the air/water heat exchanger s internal safety devices to cease cooling operation. 4 Assembly and connection Note: When using an air duct system, care must be taken to ensure that it is laid straight and without kinks wherever possible. This minimises the resistance to the cold airflow. It is important to ensure even air circulation inside the enclosure. Under no circumstances should air inlet and outlet openings be obstructed, otherwise the cooling performance of the unit will be reduced. Ensure a suitable distance from electronic components and other installed enclosures so that the required air circulation is not obstructed and prevented. One cold air outlet from the air/water heat exchanger must be kept open at all times when operating with the air duct, to prevent the accumulation of cold air inside the unit. Fig. 3: Never direct the cold airflow at active components Exercise particular caution with the airflow from the blowers of built-in electronic components (see fig. 3). Components for targeted air routing are available as accessories please refer to the Rittal Catalogue. Fig. 4: Targeted air routing inside the enclosure Note: When using the cover bungs, no more than 2 cold air outlets should be sealed. Fig. 5: Cover bungs Rittal air/water heat exchanger assembly and operating instructions 7
8 4 Assembly and connection 4.3 Assembling the air/water heat exchanger The enclosure air/water heat exchanger is fitted on the roof of the enclosure. To this end, the roof plate must be cut out as per the drilling template included with the supply. Note: Pre-configured, reinforced roof plates with cut-outs to match your enclosure are available as accessories; refer to the Rittal Catalogue Producing the mounting cut-out Stick the supplied drilling template onto the roof of the enclosure using adhesive tape. There are dimensioning lines on the drilling template to suit the installation type for your air/water heat exchanger. Risk of injury! Carefully deburr all cut-outs to prevent injuries caused by sharp edges. Make the cut-outs including the line width as per the drilling template. Deburr the cut-outs Assembling the air/water heat exchanger Stick the supplied sealing frame onto the cut out roof plate. Fig. 7: Roof plate reinforcement for the TS 8 enclosure Accessories for roof plate reinforcement with TS: Punched rail U nut Fastening bracket Threaded block (refer also to Accessories in the Rittal Catalogue) 4.4 Connecting the condensate discharge A flexible condensate discharge hose Ø 12 mm ( 1 / 2 ) can be fitted to the air/water heat exchanger. The condensate discharge must be laid with a suitable and constant gradient (no siphoning) must be laid without kinks must not have a reduced cross-section if extended The condensate hose is available as an accessory (refer also to Accessories in the Rittal Catalogue). Fig. 6: Sealing frame on roof plate Mount the air/water heat exchanger on the enclosure roof. Screw the supplied twin-threaded bolts into the holes in the plastic base on the underside of the device. Secure the unit using the supplied washers and nuts. Note: In order to achieve a permanent seal between the air/water heat exchanger and the enclosure, the mounting surface should be reinforced or supported if necessary. This is particularly applicable with large roof areas. Fig. 8: Connect the condensate discharge to the side of the unit Connect a suitable hose from the right or rear to the condensate nozzle screwed into the unit, and secure it with a hose clip (with 2 Nm torque). Lay the condensate hose, e.g. into a drain. Alternatively, the condensate discharge can also be connected on the rear of the unit. In this case, proceed as described in section Rittal air/water heat exchanger assembly and operating instructions
9 Note: To avoid kinking of the condensate hose, use the angled connector contained in the scope of supply. Ø 12 mm ( ) 4 Assembly and connection Connection on the side of the unit Push the sealing rings onto the screw connector and tighten the nozzles contained in the accessory pack with min. 25 Nm and max. 30 Nm. When doing so, ensure that the pre-assembled screw connector is not loosened from the unit. Connect a suitable hose to each of the two cooling water connection nozzles (at the side or rear of the unit) and secure each one with a hose clip (with 25 Nm torque) Connection on the rear of the unit Remove the sealing bung. Insert the screw connector removed from the side of the unit and re-seal the connector with Teflon tape or hemp and sealing paste. Proceed as described in section Subsequently use the sealing bungs to close the open connector holes on the side of the unit. Fig. 9: Lay the condensate discharge to the side of the unit 4.5 Connecting the water connection A compression-proof flexible condensate discharge hose Ø 12 mm ( 1 / 2 ) for both the supply and the return can be fitted to the air/water heat exchanger. The cooling water hose must be laid without kinks must not have a reduced cross-section if extended and, if necessary, must be insulated. Note: The water circuit should be protected from ingress of dirt or excess pressure (maximum permitted operating pressure 10 bar)! Note: Observe the flow direction and check for leaks! The unused cooling water connecting pieces must be closed appropriately with sealing bungs. Ø 12 mm ( ) Fig. 11: Lay the cooling water hose Fig. 10: Connect the cooling water inlet (top) and return (centre) to the side of the unit Rittal air/water heat exchanger assembly and operating instructions 9
10 4 Assembly and connection Notes on water quality To ensure the reliable operation of the above-mentioned units, the VBG guidelines for cooling water must be observed (VGB-R 455 P). The cooling water must not contain any limescale deposits; in other words, it should have a low level of hardness, in particular, a low level of calcium hardness. In particular, for recooling within the plant, the calcium hardness should not be too high. On the other hand, the water should not be so soft that it attacks the materials. When recooling the cooling water, the salt content should not be allowed to increase excessively due to the evaporation of large quantities of water, since electrical conductivity increases as the concentration of dissolved substances rises, and the water thereby becomes more corrosive. Always add the appropriate volume of fresh water. Always remove part of the enriched water. The following criteria for the cooling water must be observed: Water with high gypsum content is unsuitable for cooling purposes because it has a tendency to form boiler scale that is particularly difficult to remove. The cooling water should be free from iron and manganese, because otherwise deposits may occur that accumulate in the pipes and block them. At best, organic substances should only be present in small quantities, because otherwise sludge deposits and microbiological contamination may occur. 4.6 Notes on electrical installation When performing the electrical installation, it is important to observe all valid national and regional regulations as well as the provisions of the responsible power supply company. Electrical installation must only be carried out by a qualified electrician who is responsible for compliance with the existing standards and regulations Connection data The connected voltage and frequency must correspond to the values stated on the rating plate. The air/air heat exchanger must be connected to the mains via an all-pin isolating device which ensures at least 3 mm contact opening when switched off. No additional temperature control may be connected upstream of the unit at the supply end. Install the pre-fuse cited on the rating plate to protect the cable and equipment from short-circuits. The mains connection must ensure low-noise potential equalisation Overvoltage protection and supply line load The unit does not have its own overvoltage protection. Measures must be taken by the operator at the supply end to ensure effective lightning and overvoltage protection. The mains voltage must not exceed a tolerance of ±10%. In accordance with IEC , the unit is intended solely for use at sites with a continuous current-carrying capacity (incoming mains power supply) of more than 100 A per phase and with a supply voltage of 400/230 V. If necessary, the power supply company must be consulted to ensure that the continuous current-carrying capacity at the point of connection to the public grid is sufficient for connection of such a unit. The fans in single- and three-phase units are intrinsically safe (thermal winding protection). The same also applies to all transformer versions and to special-voltage units which are likewise equipped with a transformer. Install the slow pre-fuse specified on the rating plate (miniature circuit-breaker with K characteristic, motor circuit-breaker or transformer circuitbreaker) to protect the cable and equipment from short-circuits. Select a suitable motor circuitbreaker/transformer circuit-breaker in accordance with the information specified on the rating plate: Set it to the minimum specified value. This will achieve the best short-circuit protection for cables and equipment. Example: Specified setting range A; set to 6.3 A. 10 Rittal air/water heat exchanger assembly and operating instructions
11 4.6.3 Door limit switch (for units with Comfort controller only) Each door limit switch must only be assigned to one air/water heat exchanger. Several door limit switches may be connected in parallel and operated on one air/water heat exchanger. The minimum cross-section for the connection cable is 0.3 mm 2 for a cable length of 2 m. We recommend the use of a shielded cable. The line resistance to the door limit switch must not exceed a maximum of 50. The door limit switch only supports a floating connection; no external voltages. The contact of the door limit switch must be closed when the door is open. The safety extra-low voltage for the door limit switch is provided by the internal power pack: Current approx. 30 ma DC. Connect the door limit switch to terminals 1 and 2 of the connector. 4 Assembly and connection 4.7 Carrying out the electrical installation Bus connection (only when interconnecting several units with a Comfort controller) When using several air/water heat exchangers, the serial unit interface can be used to connect up to ten air/water heat exchangers with the bus cable (Model No. SK ). Note: The electrical signals at the X2 interface are of an extra-low voltage (not extra-low safety voltages in accordance with ). When interconnecting, please note the following: De-energise the air/water heat exchangers to be connected. Ensure proper electrical insulation. Make sure the cables are not laid in parallel to power lines. Make sure that the lines are short Potential equalisation Rittal recommends connecting a conductor with a nominal cross-section of at least 6 mm 2 to the potential equalisation connection point on roof-mounted air/water heat exchangers and incorporating it into the existing potential equalisation system. According to the standard, the PE conductor in the mains connection cable is not classified as an equipotential bonding conductor. CMC 1 2 RTT Master Adr.: 09 RTT Slave Adr.: 11 RTT Adr.: 12 Slave RTT Slave Adr.: 19 X1 X1 X1 X1 X2 X3 X2 X3 X2 X3 X2 X3 St. X2 X3 Bu. St. X2 St. X2 St. X2 X2 X2 X2 X2 X2 3 Bu. St. Bu. St. Bu. Fig. 12: Connection example: Master-slave operation Key 1 Serial interface 2 Serial interface cable 3 Master-slave bus cable (Model No. SK ) RTT Rittal TopTherm air/water heat exchanger X1 Supply connection/door limit switch/alarms X2 Master-slave connection Sub-D, 9-pole X3 Serial interface Sub-D, 9-pole St. Sub-D connector, 9-pole Bu. Sub-D jack, 9-pole Adr. Address Rittal air/water heat exchanger assembly and operating instructions 11
12 4 Assembly and connection X10 X2 X2 X2 X2 X2 X2 Adr.: 06 Adr.: 11 Adr.: 12 Adr.: 13 Adr.: 14 Adr.: L2 L1 N PE X10 L1 L2 L3 PE X10 L1 L2 N PE X10 L1 L2 L3 PE X10 L1 L2 L3 PE X10 L1 L2 L3 PE X2 X10 L1 L2 PE N Adr.: 16 Fig. 13: Connection example: Door limit switch and Master-slave operation Key 1 Master air/water heat exchanger 2 Slave air/water heat exchanger 3 2-door enclosure with two door limit switches 4 Enclosure with door limit switch 12 Rittal air/water heat exchanger assembly and operating instructions
13 4.7.2 Installing the power supply Complete the electrical installation as per the wiring plan inside the air/water heat exchanger underneath the cover (see fig. 29 on page 25). 4 Assembly and connection To be able to evaluate the system messages of the air/water heat exchanger via the system message relay, a corresponding low-voltage cable must be connected additionally on terminals 3 5. SK XX, SK XX Option T1 L1 L2 N PE X1 Mains L1 N PE A2 T1 L1 L N 8 L1 L N PE L N Kx 8pol to interface Power/G1 D0_A/Kx NTC I 2 B1 PE DD-E /Y1 DD-I /M A1 NTC E 2 S2 Y1 C2 M 1~ M2 Fig. 14: Electrical wiring plan no. 1 Key A1 Power PCB A2 Display terminal B1 Internal temperature sensor C2 Operating capacitors Kx Collective fault relay M2 Fan S2 Float-actuated switch T1 Transformer (optional) X1 Main terminal strip Terminals 1 and 2 are free Y1 Magnetic valve Rittal air/water heat exchanger assembly and operating instructions 13
14 4 Assembly and connection SK XX, SK XX PE Mains S1 5 T1 X1 L1 L2 L N L2 L1 N PE X2 PE 8 X3 PE A2 PE L N Power/G S1 Kx A1 MS1 NTC I Serial NTC E NTC C NTC A Level Term 2 4 B1 M1 M2 M F2 2 1 S S2 Y1 C2 M 1~ M2 Fig. 15: Electrical wiring plan no. 2 Key A1 Power PCB A2 Display terminal B1 Temperature sensor, internal temperature C2 Operating capacitors Kx Relay collective fault 1 Relay collective fault 2 M2 Fan S1 Door limit switch (without door limit switch: terminal 1, 2 open) S2 Float-actuated switch (closed without water) T1 Transformer (optional) X1 Main terminal strip X2 Master-slave connection X3 Serial interface (optional) Y1 Magnetic valve AC cos f = 1 I max. = 2 A U max. = 250 V Tab. 2: Note: For technical data, refer to the rating plate. Contact data DC L/R = 20 ms I min. = 100 ma U max. = 200 V U min. = 18 V I max. = 2 A 14 Rittal air/water heat exchanger assembly and operating instructions
15 5 Commissioning Once all the assembly and installation work is complete, switch on the power supply and the water supply to the air/water heat exchanger. The air/water heat exchanger starts running: The enclosure internal temperature is displayed. With Comfort controller: The software version of the controller first appears for approx. 2 sec., then the enclosure internal temperature appears in the 7-segment display. You can now make your individual settings on the unit, e.g. set the temperature or (with Comfort controller only) assign the network identifier, etc. (refer to the Operation chapter). 6 Operation You can operate the air/water heat exchanger using the controller on the front of the unit (fig. 1, no. 2, page 4). 6.1 Control using the Basic controller Display and system analysis H2 = Key K 1 H4 = Key set/ F 5 Commissioning General programming information Using buttons H2, H3 and H4 (fig. 16) you can change 3 parameters within the preset ranges (min. value, max. value). Tables 4 and 5 on page 16 show the parameters which can be altered Operation of the basic controller The display terminal H1 consists of a 3-position 7-segment display which indicates the temperature in C as well as any system messages. The current enclosure internal temperature is usually displayed permanently. In the event of a system message, this will alternate with the internal temperature display. Note: With the Basic controller, the temperature is preset at the factory to +35 C. In order to save energy, do not set the temperature lower than that actually necessary Setting the temperature The setting of the enclosure internal temperature is preset at the factory to 35 C. To change the value press key H2 ( K 1 ) or H3 ( K 2 ) for one second until 1 appears in the display, then confirm with the H4 set key. The set value can then be altered within the preset parameters (+20 C to +55 C) via the keys H2 ( K 1) or H3 ( K 2). Press the H4 set key for 5 seconds to save the new value. The current enclosure internal temperature is displayed again. H1 = Display terminal H3 = Key K 2 Fig. 16: Display and system analysis of the Basic controller Properties The air/water heat exchanger operates automatically, i.e. after switching on the power supply, the fan (see fig. 2, page 4) will run continuously and permanently circulate the internal enclosure air. The magnetic valve controls the cooling water flow as specified by the temperature setpoint. The built-in Basic controller ensures automatic normal shut-down operation of the air/water heat exchanger by the value of the fixed preset switching difference of 5 K. Alarm no. HI LO IA Tab. 3: System message Internal temperature of enclosure too high Internal temperature of enclosure too low Leakage warning/ condensate warning Cause Cooling capacity inadequate/ unit undersized/ unit defective Ambient temperature too low/ no heat loss in the enclosure Heat exchanger leaky/condensate discharge kinked or blocked Remedy Check cooling capacity/ check unit Check unit Check heat exchanger for leaks/ check condensate discharge Warning messages on the display and monitoring of the min./max. internal temperature Rittal air/water heat exchanger assembly and operating instructions 15
16 6 Operation Setting of system messages To change the system messages keep the H4 set key pressed for 5 seconds. The controller is now in programming mode. While in programming mode, if you do not press any buttons for approx. 60 sec., the display will first flash, then the controller will switch back to normal display mode. You can then navigate in the levels with the H2 ( K 1 ) or H3 ( K 2 ) keys (see table 3). The level is selected by pressing the H4 button. The parameters are changed with the H2 ( K 1 ) or H3 ( K 2 ) keys. Press the H4 set key for 5 seconds to confirm the new value Programming and control of the Basic controller See also fig. 17 on page 17. Progr. level Display screen Parameters Min. value Max. value Factory setting Description 0 Ps No function 1 1 Setpoint Enclosure internal temperature T i The setting of the enclosure internal temperature is preset at the factory to 35 C and may be altered within a range of +20 C to +55 C. When the setpoint is reached, the H2 ( K 1) key is lit continuously. Tab. 4: Setting the setpoint Progr. level Display screen Parameters Min. value Max. value Factory setting Description 2 H5 Software version number 3 AH Alarm maximum temperature 4 AL Alarm minimum temperature 5 r8 Reset of r6 and r7 6 r7 Querying of the max. internal temperature 7 r6 Querying of the max. internal temperature Displays the current version number of the device software. AL Maximum temperature alarm (NOT in relation to the nominal value). HI is displayed alternating with the internal temperature. The HI alarm is displayed when the internal temperature > HI. The alarm stops when the internal temperature < AH 2K. 50 AH 20 Minimum temperature alarm (NOT in relation to the nominal value). LO is displayed alternating with the internal temperature. The LO alarm is displayed when the internal temperature < LO. The alarm stops when the internal temperature > AL +2K Reset of r6 and r7. Set this parameter to 1 to reset the stored maximum and minimum values of r6 and r7 to the respective current actual value Stores the min. internal enclosure temperature occurring after > 1 min Stores the max. internal enclosure temperature occurring after > 1 min. Tab. 5: Setting the system messages, monitoring of the min./max. enclosure internal temperature 16 Rittal air/water heat exchanger assembly and operating instructions
17 6.1.8 Reset of r6 and r7 (min./max. internal temperature) To reset the stored internal temperatures keep the H4 set key pressed for 5 seconds. Navigate to level r8 with the H2 ( K 1 ) or H3 ( K 2 ) keys. Press the H4 set key and change the parameter from 0 to 1 using the H2 ( K 1 ) or the H3 ( K 2 ) keys. Press the H4 set key for 5 seconds to confirm resetting the values. 6 Operation System message contact (; floating) The relay is normally closed. All assigned system messages lead to the relay dropping out and likewise to loss of the control voltage. Terminal strip X1 provides the connection. For contact data and occupancy see the wiring diagram in chapter Installing the power supply, page 13. fault signal relay (normally open contact/changeover contact) Terminal 3: NC (normally closed) Terminal 4: C (connection of the supply voltage to the fault signal relay) Terminal 5: NO (normally open) The NC and NO definitions refer to the de-energised state Programming overview of Basic controller Setpoint = 1 sec. = 1 sec. Parameters = 5 sec. = 5 sec. Fig. 17: Programming overview of Basic controller Rittal air/water heat exchanger assembly and operating instructions 17
18 6 Operation 6.2 Control using the Comfort controller For unit types SK XX and SK XX. Fig. 18: 4 3 Comfort controller 1 2 Key 1 Programming button, also display of the set temperature unit (degrees Celsius) 2 Set button 3 Programming button, also display of the set temperature unit (degrees Fahrenheit) 4 7-segment display Properties Integral start-up delay and door limit switch function Monitoring of all motors (fans) Master-slave function with a maximum of ten units. One unit functions as a master unit. Once the set temperature is reached by one of the connected slave units or in the event of the door limit switch function, the affected slave unit will report to the master unit, which will switch all the other air/water heat exchangers on or off as required. Switching hysteresis: Adjustable from 2 10 K, preset to 5 K. Visualisation of the current enclosure internal temperature and all error messages in the 7-segment display. The current enclosure internal temperature is usually displayed permanently. In the event of an error message, this will alternate with the temperature display. The unit is programmed using buttons 1 3 (fig. 18). The relevant parameters also appear in the display Launching test mode The Comfort controller is equipped with a test function, whereby the air/water heat exchanger commences cooling operation independently of the set temperature or door limit switch function. Simultaneously press buttons 1 and 2 (fig. 18) for at least 5 seconds. The air/water heat exchanger starts running. After approximately 5 minutes or upon reaching 15 C, test mode will end. The unit switches off and changes to normal operation General programming information Using buttons 1, 2 and 3 (fig. 18) you can change 24 parameters within the preset ranges (min. value, max. value). Tables 6 and 7 show the parameters which can be altered. Fig. 20 on page 21 shows which buttons must be pressed. Note on switching hysteresis: With a low hysteresis and short switching cycles, there is a risk that cooling may not be adequate or that only partial sections of the enclosure are cooled. Note on temperature settings: With the Comfort controller, the temperature is preset at the factory to +35 C. In order to save energy, do not set the temperature lower than that actually necessary. The air/water heat exchanger operates automatically, i.e. after switching on the power supply, the fan (see page 4, fig. 2) will run continuously and permanently circulate the internal enclosure air. The fan and the magnetic valve are controlled by the Comfort controller. The Comfort controller has a 7-segment display (fig. 18, no. 4). After switching on the power supply, the current software version initially appears on this display for approx. 2 seconds. In regular operation, the display shows both the temperature (in degrees Celsius or Fahrenheit users may switch between the two) and any error messages. 18 Rittal air/water heat exchanger assembly and operating instructions
19 In principle, the programming is identical for all editable parameters. To enter programming mode: Press button 2 ( Set ) for approx. 5 seconds. The controller is now in programming mode. While in programming mode, if you do not press any buttons for approx. 30 sec., the display will first flash, then the controller will switch back to normal display mode. The Esc display indicates that any changes made have not been saved. Press the programming buttons ( C) or ( F) to switch back and forth between the editable parameters (see tables 4 and 5). Press button 2 ( Set ) to select the displayed parameter for editing. The current value of this parameter is displayed. Press one of the programming buttons ( C) or ( F). The Cod display will appear. In order to be able to change a value, you must enter the authorisation code 22. Keep the programming button ( C) held down until 22 appears. Press button 2 ( Set ) to confirm the code. You can now alter the parameter within the preset limits. Press one of the programming buttons ( C) or ( F) until the required value appears. Press button 2 ( Set ) to confirm the change. You can now alter other parameters in the same way. There is no need to re-enter the authorisation code 22. To exit programming mode, press button 2 ( Set ) again for approximately 5 seconds. Acc will appear in the display to indicate that the changes have been saved. The display will then switch back to regular operation (enclosure internal temperature). You can also program the Comfort controller using a diagnosis software package (Model No. SK ), the supply of which also includes a connection cable to the PC. The cable connector on the rear of the Comfort controller display serves as an interface. 6 Operation Eco-mode All Rittal TopTherm heat exchangers with e-comfort controller from firmware 3.2 have the energy-saving eco-mode, which is activated in the delivered state. The eco-mode is used to save energy in the heat exchanger if there is no thermal load, or there is a low thermal load in the enclosure (e.g. standby operation, no production or weekend). During this process the heat exchanger fan in the internal circuit is switched off as appropriate if the actual enclosure internal temperature drops to 10 K below the setpoint temperature set. To reliably measure the internal temperature also during this process, the fan starts cyclically for 30 sec. every 10 minutes (see fig. 19). If the internal temperature reaches the range 5 K below the setpoint set again, the fan switches back to continuous operation. If required, the eco-mode can be deactivated via the control display. For this purpose switch the parameter from 1 to 0 in the programming level (see table 6, page 20). The fan then runs continuously. Internal temperature Status internal fan Fig. 19: 10 min. Diagram of eco-mode 10 min. 30 sec. Time Setpoint 5 C Setpoint 10 C ON OFF Rittal air/water heat exchanger assembly and operating instructions 19
20 6 Operation Editable parameters See also fig. 20 on page 21. Progr. level Display screen Parameters Min. value Max. value Factory setting Description 1 St Setpoint enclosure internal temperature T i Tab. 6: Editable parameters The setting of the enclosure internal temperature is preset at the factory to 35 C and may be altered within a range of C. 2 Mod Control mode Control mode setting. The temperature control is made as factory setting with the magnetic valve (0). It is, however, possible to change the temperature control by starting and stopping the internal fan (1); the magnetic valve then remains permanently open. You must obtain the manufacturer s consent before changing to control mode (1). 3 Ad Master-slave identifier 4 CF Changeover C/ F 5 H1 Setting switching difference (hysteresis) 6 H2 Differential for error message A2 26 ECO Eco-mode operation See Setting the Master-slave identifier, page The temperature display can be switched from C (0) to F (1). The corresponding LED displays the current unit of temperature The air/water heat exchanger is preset in the factory to a switching hysteresis of 5 K. This parameter should only be changed in consultation with us. Please contact us for advice If the internal enclosure temperature exceeds the set value by more than 5 K, then error message A2 (enclosure internal temperature too high) appears on the display terminal. If necessary, the differential may be altered here within the range from 3 15 K Eco-mode OFF: 0 / Eco-mode ON: 1 20 Rittal air/water heat exchanger assembly and operating instructions
21 6.2.6 Programming overview = 5 sec. 6 Operation = 5 sec. Fig. 20: Programming overview Rittal air/water heat exchanger assembly and operating instructions 21
22 6 Operation Defining system messages for evaluation System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. A more detailed explanation of the system messages may be found in section Evaluating system messages, page 23. See also fig. 20 on page 21. Progr. level Display screen Min. value Max. value Factory setting Type or location of fault 7 A Enclosure door open 8 A Internal temperature of enclosure too high 9 A Condensate warning 10 A Fan blocked or defective 11 A Internal temperature sensor 12 A EPROM 13 A LAN/Master-Slave 14 A Voltage drop Tab. 7: System messages which may be evaluated via relays The system messages A01 A20 may additionally be evaluated via two floating system message relays. In this way, one of the two system message relays may be allocated to each system message. See wiring diagrams at section Installing the power supply, page 13: Terminal 3: NO (normally open, relay 2) Terminal 4: Connection of the supply voltage to the system message relay Terminal 5: NO (normally open, relay 1) The definition NO refers to the de-energised state. As soon as power is applied to the air/water heat exchanger, both system message relays (relay 1 and 2) energise. This is the normal operating state of the air/water heat exchanger. As soon as a system message occurs or the power supply is interrupted, the corresponding relay will drop out and open the contact. Program system messages with the value 0: System message is not sent to the system message relays, but merely appears in the display 1: System message is evaluated by relay 1 2: System message is evaluated by relay Setting the Master-slave identifier When several air/water heat exchangers are connected together (maximum ten), one of the air/water heat exchangers must be defined as the master and the others as slaves. For this purpose, assign a corresponding identifier (address) to each air/water heat exchanger which will enable the air/water heat exchanger to be identified in the network. If one of the slave units reaches the set temperature or if the door limit switch function is activated, the affected slave unit will report to the master unit, which then deactivates all the other air/water heat exchangers. Notes: Only one unit may be configured as master, and its identifier must match the number of connected slave units. The slave units must have different identifiers. The identifiers must be numbered in ascending order without any gaps. 22 Rittal air/water heat exchanger assembly and operating instructions
23 On the master air/water heat exchanger (00 = factory setting), set the number of slave units present in the network: 01: Master with 1 slave air/water heat exchanger 02: Master with 2 slave air/water heat exchangers 03: Master with 3 slave air/water heat exchangers 04: Master with 4 slave air/water heat exchangers 05: Master with 5 slave air/water heat exchangers 06: Master with 6 slave air/water heat exchangers 07: Master with 7 slave air/water heat exchangers 08: Master with 8 slave air/water heat exchangers 09: Master with 9 slave air/water heat exchangers 6 Operation On the slave air/water heat exchanger (00 = factory setting), set its own address: 11: Slave air/water heat exchanger no. 1 12: Slave air/water heat exchanger no. 2 13: Slave air/water heat exchanger no. 3 14: Slave air/water heat exchanger no. 4 15: Slave air/water heat exchanger no. 5 16: Slave air/water heat exchanger no. 6 17: Slave air/water heat exchanger no. 7 18: Slave air/water heat exchanger no. 8 19: Slave air/water heat exchanger no. 9 Master 02 Slave 11 Slave 12 Fig. 21: Master-slave connection (example) For further connection examples, see Bus connection (only when interconnecting several units with a Comfort controller), page 11. For details of how to set the identifier, see Editable parameters, page 20 or Programming overview, page 21, parameter Ad Evaluating system messages In the Comfort controller, system messages are indicated by a number in the display. Display screen A01 Enclosure door open Door open or door limit switch incorrectly positioned A02 Tab. 8: System message Possible cause Measures to rectify the fault Internal temperature of enclosure too high Troubleshooting with the Comfort controller Cooling capacity inadequate/ unit undersized A08 Condensate warning Condensate discharge kinked or blocked Close door, position door limit switch correctly, check connection if necessary Check cooling capacity Check condensate discharge; repair any kinks or blockages in the hose A10 Fan Blocked or defective Clear the blockage; replace if necessary A16 Temperature sensor Open or short-circuit Replace internal temperature A18 EPROM error New board obstructed Software update needed (only following board installation with more recent software): Enter the programming level with Code 22; press button 1 and confirm with Set until Acc appears. Next, disconnect the unit from the mains and reconnect. A19 LAN/Master-Slave Master and slave not connected Check setting and/or cable A20 Voltage drop Error display not shown Event is stored in the log file E0 Display message Connection problem between the display and the controller board Cable defective; connection loose Reset: Switch power supply off, then switch on again after approx. 2 sec. Exchange the boards Rittal air/water heat exchanger assembly and operating instructions 23
24 7 Inspection and maintenance 7 Inspection and maintenance Risk of electric shock! The unit is live. Switch off the power supply before opening, and take suitable precautions against it being accidentally switched on again. 7.1 General The air/water heat exchanger is largely maintenancefree. The water circuit is checked at the factory for leaks and subjected to a function trial run. The installed maintenance-free fan is mounted on ball bearings, protected against moisture and dust, and fitted with a temperature monitor. The life expectancy is at least 30,000 operating hours. The air/water heat exchanger is consequently largely maintenance-free. If dirt is present in the cooling water, a filter must be fitted. Maintenance interval: 2000 operating hours. Fig. 23: Release the louvred grille Fig. 24: Remove the louvred grille Fig. 25: Disconnect the connector from the display Caution! Risk of fire! Never use flammable liquids for cleaning. Sequence of maintenance measures: Check the level of dirt. Cooling membranes soiled? Clean if necessary. Activate test mode; cooling function OK? Check the noise generation of the fan. Fig. 22: 24 Disconnect the mains plug Rittal air/water heat exchanger assembly and operating instructions
25 7 Inspection and maintenance Fig. 26: Disconnect the earthing cable Fig. 27: Remove the assembly screws from the cover (loosen four screws) Fig. 28: Remove the cover Rittal air/water heat exchanger assembly and operating instructions Fig. 29: Air/water heat exchanger without cover (front view) Fig. 30: Air/water heat exchanger without cover (rear view) 25
26 8 Emptying, storage and disposal 8 Emptying, storage and disposal Caution! Risk of damage! The air/water heat exchanger must not be subjected to temperatures above +70 C during storage. During storage, the air/water heat exchanger must stand upright. Disposal can be performed at the Rittal plant. Please contact us for advice. Emptying (for units with Basic controller only): During storage and transportation below freezing point, the air/water heat exchanger should be drained completely in the water supply direction using compressed air. This requires that the magnetic valve be opened. For the Comfort controller, this is achieved by simultaneously pressing the H2 ( C key) and H4 (/set key) keys for five seconds. The magnetic valve is then opened for approximately five minutes. 26 Rittal air/water heat exchanger assembly and operating instructions
27 9 Technical specifications 9 Technical specifications Observe the mains connection data (voltage and frequency) as per the rating plate. Observe the pre-fuse as per the specifications on the rating plate. Fig. 31: Rating plate (technical data) Basic controller, RAL 7035 Comfort controller, RAL 7035 Rated voltage Unit Model No. SK V Hz 230, 1~, 50/60 115, 1~, 50/60 400, 2~, 50/60 230, 1~, 50/60 115, 1~, 50/60 400, 2~, 50/60 Rated current A 0.40/ / / / / /0.30 Pre-fuse T A 4.0/ / / / / /4.0 Motor circuit-breaker Transformer circuit-breaker Miniature circuit-breaker Useful cooling. W 2500 output Q k L 35 W 10 l/h 400 to DIN 3168 Admissible pressure bar 1 to 10 Water inlet temperature C +1 to ±30 Temperature setting range C +1 to +70 Noise level db (A) Electrical connection Plug-in terminal strip Water connection Hose nozzle or 3 / 8 external thread Protection category to IEC IP 55 Dimensions (W x H x D) mm 597 x 417 x 475 Air throughput of fans (unimpeded airflow) m 3 /h 1030 Weight kg Rittal air/water heat exchanger assembly and operating instructions 27
28 9 Technical specifications Basic controller, RAL 7035 Comfort controller, RAL 7035 Rated voltage Unit Model No. SK V Hz 230, 1~, 50/60 115, 1~, 50/60 400, 2~, 50/60 230, 1~, 50/60 115, 1~, 50/60 400, 2~, 50/60 Rated current A 0.40/ / / / / /0.30 Pre-fuse T A 4.0/ / / / / /4.0 Motor circuit-breaker Transformer circuit-breaker Miniature circuit-breaker Useful cooling. W output Q k L 35 W 10 l/h to DIN 3168 Admissible pressure bar 1 to 10 Water inlet temperature C +1 to ±30 Temperature setting range C +20 to +55 Noise level db (A) Electrical connection Plug-in terminal strip Water connection Hose nozzle or 3 / 8 external thread Protection category to IEC IP 55 Dimensions (W x H x D) mm 597 x 415 x 475 Air throughput of fans (unimpeded airflow) m 3 /h Weight kg Rittal air/water heat exchanger assembly and operating instructions
29 10 List of spare parts List of spare parts Fig. 32: Spare parts for SK 3209.XXX, SK 3210.XXX Key 10 Fan, complete 15 Dispatch bag 32 Magnetic valve, complete 33 Non-return valve 40 Controller board 45 Louvred grille 55 Display 71 Temperature probe 73 Float-actuated switch 75 Cover 91 Heat exchanger 95 Base tray Note: As well as the spare part number, when ordering spare parts the following information must be provided: Unit model Fabrication number Date of manufacture This information may be found on the rating plate. Rittal air/water heat exchanger assembly and operating instructions 29
30 11 Further technical information 11 Further technical information 11.1 Hydrological data To avoid system damage and to ensure safe operation, Rittal GmbH & Co. KG recommends the use of system water or an additive whose composition does not differ from that presented in the following summary: Hydrological data Unit Model No. SK Model no. SK 1) Tab. 9: Hydrological data / / / / / / / / ph value Calcium hardness dh 3 < Free carbonic acid mg/dm Corresponding carbonic acid mg/dm free Aggressive carbonic acid mg/dm Sulphides mg/dm 3 free free Oxygen mg/dm 3 < 10 < 10 Chloride ions mg/dm 3 < 50 < 200 Sulphate ions mg/dm 3 < 250 < 500 Nitrates and nitrites mg/dm 3 < 10 < 100 COD mg/dm 3 < 7 < 40 Ammonia mg/dm 3 < 5 < 20 Iron mg/dm 3 < 0.2 free Manganese mg/dm 3 < 0.2 free Conductivity µs/cm < 2200 < 4000 Evaporation residue mg/dm 3 < 500 < 2000 Potassium permanganate mg/dm 3 < 25 < 40 Suspended matter mg/dm 3 > 3 < 15: Partial current purification recommended < 3 > 15: continuous purification recommended / / / / / / / / ) The complete absence of corrosion under experimental conditions suggests that solutions with a significantly higher salt content and greater corrosion potential (such as seawater) can still be tolerated. 30 Rittal air/water heat exchanger assembly and operating instructions
31 11.2 Characteristic curves Water resistance 11 Further technical information P: Water resistance [mbar]. V: Volumetric flow [l/h] Fig. 33: Water resistance SK P: Water resistance [mbar]. V: Volumetric flow [l/h] Fig. 34: Water resistance SK Rittal air/water heat exchanger assembly and operating instructions 31
32 11 Further technical information P: Water resistance [mbar]. V: Volumetric flow [l/h] Fig. 35: Water resistance SK 3210.XX P: Water resistance [mbar]. V: Volumetric flow [l/h] Fig. 36: Water resistance SK 3210.XX4 32 Rittal air/water heat exchanger assembly and operating instructions
33 12 Appendix 1: Cut-out and hole sizes 12.1 Dimensions for assembly 12 Appendix 1: Cut-out and hole sizes Ø (4x) Fig. 37: SK 3209.XXX/SK 3210.XXX assembly 13 Appendix 2: Preparation and maintenance of the water in recooling systems Depending on the type of installation to be cooled, certain requirements are placed on the cooling water with respect to purity. According to the level of contamination and the size and design of the recooling systems, a suitable process is used to prepare and/ or maintain the water. The most common types of contamination and most frequently used techniques to eliminate them in industrial cooling are: Contamination of the water Mechanical contamination Excessive hardness Moderate content of mechanical contaminants and hardness components Moderate content of chemical contaminants Biological impurities myxobacteria and algae Procedure Filter the water using: Mesh filter Gravel filter Cartridge filter Precoated filter Water softening via ion exchange Addition of stabilisers and/or dispersing agents to the water Addition of passifiers and/or inhibitors to the water Addition of biocides to the water Tab. 10: Water contaminants Rittal air/water heat exchanger assembly and operating instructions 33
34 Enclosures Power Distribution Climate Control IT Infrastructure Software & Services 3. edition / ID no / Drawing no. A RITTAL GmbH & Co. KG Postfach 1662 D Herborn Phone +49(0) Fax +49(0) [email protected]
SK 3373.XXX SK 3374.XXX SK 3375.XXX SK 3363.XXX SK 3364.XXX
Luft/Wasser-Wärmetauscher Air/water heat exchangers Echangeurs thermiques air/eau Lucht/water-warmtewisselaars Luft/vatten värmeväxlare Scambiatori di calore aria/acqua Intercambiadores de calor aire/agua
Schaltschrank-Kühlgerät Cooling unit Climatiseur Koelaggregaat Kylaggregat Condizionatore per armadi Refrigerador para armarios
Schaltschrank-Kühlgerät Cooling unit Climatiseur Koelaggregaat Kylaggregat Condizionatore per armadi Refrigerador para armarios SK 3359.xxx SK 373.xxx SK 338.xxx SK 3383.xxx SK 3384.xxx SK 3385.xxx SK
Schaltschrank-Kühlgerät Cooling unit Climatiseur Koelaggregat Kylaggregat Condizionatori per armadi di comando Refrigerador para armarios
Schaltschrank-Kühlgerät Cooling unit Climatiseur Koelaggregat Kylaggregat Condizionatori per armadi di comando Refrigerador para armarios SK 330.xxx SK 330.3xx SK 3303.xxx SK 3304.xxx SK 3305.xxx SK 338.xxx
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
instabus KNX / EIB System System E F G H
Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
PWS Series Air/Water Heat Exchangers
ELECTRO-TECHNOLOGY FOR INDUSTRY PWS Series Air/Water Heat Exchangers Installation, Operation and Service Manual Safety for man, machine and the environment TABLE OF CONTENTS SECTION 1: HOW TO USE THIS
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
KNX R. Rain Sensor. Installation and Adjustment
EN KNX R Rain Sensor Installation and Adjustment 1 Content 1. Description... 3 1.1. Technical specifications... 3 2. Installation and commissioning... 4 2.1. Installation notes... 4 2.2. Location... 4
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
Technical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
ABB i-bus KNX Fan Coil Controller FC/S 1.1
Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation
CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor
CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor 7030.111 Montage-, Installations- und Bedienungsanleitung Assembly and operating instructions Foreword Foreword Dear Customer, Thank
RITTAL TOP THERM SK 3201.200 SK 3201.300. RITTAL Thermoelectric Cooler
RITTAL TOP THERM Schaltschrank- Klimagerät Climate control unit Climatiseur Klimaat unit Kylaggregat Condizionatore per armadi Refrigerador para armarios RITTAL Thermoelectric Cooler SK 3201.200 SK 3201.300
ABB i-bus KNX SA/S Switch Actuators Product Manual
ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional
SELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119
EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70
Elektromotoren und Gerätebau Barleben GmbH
Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Transformer Protection Relay NM Series (Buchholz principle) Elektromotoren und Gerätebau Barleben GmbH Table of contents Page 1. Safety
Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
INSTALLATION INSTRUCTIONS: Viewline 52 mm
-5 Safety information The product was developed, manufactured and inspected according to the basic safety requirements of EC Guidelines and state-of-the-art technology. The instrument is designed for use
CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/
CW-5000/ 5200 Contents Cautions ---------------------------------------------------------------- 3 Parts introduction --------------------------------------------------- 4 Installation ------------------------------------------------------------
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
Cooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
INSTALLATION INSTRUCTIONS: Viewline 85 mm
1-10 1 Safety information The product was developed, manufactured and inspected according to the basic safety requirements of EC Guidelines and state-of-the-art technology. The unit is designed for use
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
6720616592.00-1.SD. Flat roof. Rack Mounting. Installation instructions 6 720 647 036 (2010/11) AU
6720616592.00-1.SD Flat roof Rack Mounting AU Installation instructions 2 Contents AU Contents 1 Key to symbols and safety instructions....... 3 1.1 Explanation of symbols................ 3 1.2 Safety
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en
8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................
Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors
European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Thermo Top - Troubleshooting Tree
Thermo Top - Troubleshooting Tree 07-15-2002 CAUTION Troubleshooting requires comprehensive knowledge about the structure and theory of operation of the Thermo Top heater. Troubleshooting and repairs may
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Operating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)
Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller
Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
LUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Cooling system components, removing and installing
Volkswagen Touareg 3.2 - Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! Hot steam may escape when opening expansion tank.
3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
SIMATIC S7-300. Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01
SIMATIC S7-300 Getting Started for First Time Users Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01 Safety Guidelines This manual contains notices you have to observe in order to ensure your personal
Operating instructions
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 [email protected] www.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND S 1.1 Levels of hazard
AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5
AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL
Operating Instructions
Operating Instructions Control unit Ex p > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
VLT Series 3500 Adjustable Frequency Drive Instruction Manual
Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases
Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases
ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:[email protected] www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
Emergency lighting units EM powerled
M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year
Wind Sensor W-RS485 with RS485 Interface
Wind Sensor W-RS485 with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93
Volkswagen Golf 5 2004-> VW Rabbit GTI 2006->
Стр. 1 из 24 Volkswagen Golf 5 2004-> VW Rabbit GTI 2006-> 19-1 Cooling system components Warning! Hot steam may escape when opening expansion tank. Wear protective goggles and protective clothing to prevent
GREISINGER electronic GmbH
T38.0.0X.6C-03 CO2 - Transmitter Operating Manual GT10 - CO2-1R GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, email: [email protected]
XL PREMIUM OIL COOLER KIT
-J05 REV. 0-0-0 XL PREMIUM OIL COOLER KIT GENERAL Kit Number 0008 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English
Low Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
AIR CONDITIONER INSTALLATION MANUAL
INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by
Electronically Controlled Instantaneous Water Heaters Models: DEX & DBX
Installation, Maintenance and User Instructions Zip InLine Electronically Controlled Instantaneous Water Heaters Models: DEX & DBX Issued August 2014 The terms Zip and InLine are registered trademarks
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
User manual. Solid (FR 98,),
User manual Solid (FR 98,), If these instructions are not followed during installation and service, Thermia Värme ABliability according to the applicable warranty is not binding. Thermia Värme AB retains