POST FRAME LIGHT GAUGE APPLICATION GUIDE
|
|
|
- Virginia Barnett
- 9 years ago
- Views:
Transcription
1 POST RAME LIGHT GAUGE APPLICATION GUIDE Lebanon, PA Bridgton, ME Howe, IN
2
3 Post rame Light Gauge Guage Post rame Trim Table of Contents Light Gauge Trim LG 02 - LG 03 Application Guidelines Safety and Minimum Slope LG 04 Handling and Storage LG 05 Installation / Ventilation / Cutting LG 06 Coverage / Overlap/Screw / Nail Patterns LG 07 - LG 08 Post rame Details Post rame Ridge and Hip LG 09 Post rame Rake & Corner LG 10 Post rame Base Angle LG 11 Post rame ascia LG 12 Post rame Gable LG 13 Post rame J Channel LG 14 Post rame Double Angle LG 15 Post rame Sidewall LG 16 Post rame Drip Cap LG 17 Post rame Post Trim LG 18 Post rame Endwall LG 19 Post rame & J Trim LG 20 Post rame Inside Corner LG 21 Post rame Overhead Door LG 22 Post rame Track Cover LG 23 Post rame Drip Edge LG 24 Post rame ascia & Soffit LG 25 Post rame ormed Valley LG 26 Post rame Notched Endwall LG 27
4 Post rame Light Gauge Guage A L C G P M E O B K H N I A 29 Ga. 13 Univ. Ridge 10 6 TLURC1xx Purpose: 4 4 J Coverage/Overlap and Screw/Nail Pattern of Everlast II Everlast II Post rame Trim This application guide is intended to assist in the application of light gauge Everlast Roofing products on post frame structures. The details and 4 1/2 illustrations in this manual may not be applicable to all building plans or field situations. It is the buyer's responsibility to verify all applicable code requirements, check all field measurements, and determine suitability of the material for the job. 1 3/4 E 5/8 29 Ga. ascia Trim 10 2 TLT4xx 3 4 1/2 1 3/4 B C E 29 Ga. Rake & Corner TLRC2xxxx 4 1/2 7/8 29 Ga. 6.5 Drip Trim Edge 10 2 TL6.560xx 4 3/4 3/4 1/ 2 C I P D 29 Ga. Gable Trim 10 2 TLGT5xx 2 5 1/ 4 1/2 7/8 29 Ga. J Channel 10 2 TLJC6xx / C G 29 Ga. AG4 Gable Trim 10 2 TLS17xx 1/8 4 1/2 29 Ga. Double Angle 10 2 TLDA7xx 4 / / 4 1/8 1/2 D H 29 Ga. Base Angle 10 2 TLBA3xx 1 3/4 1 1/2 29 Ga. Univ. Sidewall 10 2 TLUS8xx 2 5/8 LG-02 7/8 7/ /2 7/8 I 29 Ga. Drip Cap 10 2 TLDC9xx J 29 Ga. Post Trim K 29 Ga. Notched Endwall EL K 29 Ga. Univ. Endwall L 29 Ga. & J
5 A L C G P M E O B K H N I A 1 3/4 29 Ga. 13 Univ. Ridge 10 6 TLURC1xx 5/ /4 J Post rame Trim D Everlast Coverage/Overlap II Post rame and Screw/Nail Trim Pattern of Everlast II B C 29 Ga. Rake & Corner TLRC2xxxx 4 1/2 7/8 4 1/2 C 29 Ga. Gable Trim 10 2 TLGT5xx 2 5 1/ 4 1/2 7/8 C 29 Ga. AG4 Gable Trim 10 2 TLS17xx 1/8 4 1/2 4 1/8 1/2 D 29 Ga. Base Angle 10 2 TLBA3xx 1 3/4 1 1/2 E 29 Ga. ascia Trim 10 2 TLT4xx 3 4 1/2 E 29 Ga. 6.5 Drip Trim Edge 10 2 TL6.560xx 4 3/4 3/4 1/ 2 I P 29 Ga. J Channel 10 2 TLJC6xx / G 29 Ga. Double Angle 10 2 TLDA7xx 4 / 3 7/8 1 2 / H 29 Ga. Univ. Sidewall 10 2 TLUS8xx 2 5/8 7/ /2 7/8 I 29 Ga. Drip Cap 10 2 TLDC9xx J P 29 Ga. Post Trim 10 2 TLPT10xxxx K 29 Ga. Notched Endwall EL 42 TLNEEL32xx K 29 Ga. Univ. Endwall 10 2 TLUE11xx L 29 Ga. & J 10 2 TLJ12xx 3/8 2 7/8 1 1/2 3 1/2 5 1/ /4 7 1/2 7 3/4 9 3/ Notched to fit panel profile /16 7/8 2 3/8 L 29 Ga ascia & Soffit 10 2 TLS17xx M 29 Ga. Inside Corner 10 2 TLIC13xx N P 29 Ga. Overhead Door TLODT14xx O 29 Ga. Track Cover Cannonball M 10 2 TLCT15xx 5 1/2 11 1/4 7/8 1 3/4 1 3/4 Jan /4 5/8 4 3/ /2 4 1/2 9 8 / 7 1 1/2 7 5/ 8 / LG-03
6 Post rame Light Guage Gauge Application Guidelines Safety: Always work safely when installing metal products. Use extreme caution on a roof at all times, and wear gloves and safety glasses to avoid injury. Hearing protection should be used when power-cutting metal panels. Do not walk on panels until all fasteners are installed. Metal panels are slippery when wet, dusty, frosty or oily. Do not attempt to walk on a metal roof under these conditions. Always use OSHA recommended safety harness or equipment when working on a roof. Wear soft-soled shoes to improve traction and to minimize damage to the paint finish. Always be aware of your position on the roof relative to any roof openings, roof edges, co-workers, and penetrations. Installing metal panels on a windy day can be dangerous and should be avoided. Consult OSHA guidelines for more comprehensive safety requirements. Minimum Slope: Everlast Roofing light gauge products are designed to be installed on pitches of no less than 3:12. Please contact an Everlast sales representative for product recommendations on lower sloped roofs. ALLOWABLE UNIORM LIVE LOADS IN POUNDS PER SQUARE OOT Live Load based on L/180 deflection Wind Load (Stress) Span (eet) 2ʹ0ʺ 2ʹ6ʺ 3ʹ0ʺ 3ʹ6ʺ 4ʹ0ʺ 2ʹ0ʺ 2ʹ6ʺ 3ʹ0ʺ 3ʹ6ʺ 4ʹ0ʺ 29 Gauge (.015) Maximum allowable loads are based upon a continuous three span sheet application. 2. Calculated in accordace with the 1996 AISI Cold ormed Steel Design Manual. 3. Maximum allowable loads for wind have been increased by 33%. 4. Allowable deflection loads are limited by a maximum deflection ratio of L/180 of span. 5. Everlast Roffing, Inc. reserves the right to change the specifications of its products without notice. LG-04
7 Post rame Light Guage Gauge Handling: A. Do not lift panels from ends while flat. Lift the panels on edge when moving individual panels or when moving panels onto the roof. B. Do not unload in a jerking or bouncing fashion. While unloading, the bundle must be handled at lift point, specified by Everlast Roofing, Inc. s greater than 25' long should be unloaded using spreader bar to prevent panels from bending. C. Although the paint coating is tough, dragging panels across the surface of one another will almost certainly damage the finish. Improper handling of metal panels may cause scratches to the paint finish. ELR offers matching touch up paint in a variety of standard colors in the event of any scratches to the paint finish. Please note: touch up paint will not weather as well or at the same rate as the original coating or finish. Storage: A. If the material is not to be used immediately, it should be stored in a dry place. Moisture trapped between sheets may cause damage to the paint system. The paint system may become soft or water stains may appear which can detract from the appearance and affect the service life of the material. To avoid problems store the materials in a well-ventilated dry area. Stack the materials in an incline position. DO NOT USE PLASTIC TO COVER MATERIALS. THIS CAN CAUSE SWEATING OR CONDENSATION! LG-05
8 Post rame Light Gauge Guage Installation Recommendations: - s can be installed over open purlins. See load chart for spacing - s should be installed against any prevailing wind - s should be installed square, plumb and properly aligned to one another - Galvanized and galvalume panels should remain void of any condensation containing copper, lead or uncoated steel materials - In situations where an endlap of a panel is required, be certain to overlap upper panel a minimum of 8 over lower panel and apply sealant and butyl lap tape uniformly between the two panels. Ventilation/Insulation: Proper design and installation of vapor barriers and ventilation systems are important to prevent condensation and the resulting problems of moisture damage and loss of insulation efficiency. Condensation occurs when moistureladen air comes in contact with a surface temperature equal to or below the dew point of the air. This phenomenon creates problems that are not unique to metal buildings; these problems are common to all types of construction. In addition to providing resistance to heat transfer, insulation can also protect against condensation forming on cold surfaces, either inside the building or within the wall/roof/system cavity. The arrangement of the building s insulation system and vapor retarder is the responsibility of the building designer. These are some basic guides to help control condensation. A. The insulation should have a vapor retarder face on the warm side of the insulation. or most buildings, this means that the vapor retarder is on the inside surface (toward the building s interior). B. The thickness of the insulation must be designed to maintain temperature of the vapor retarder above the interior dew point, using the worst-case expected outside temperature. C. All perimeter conditions, seams, and penetrations of the vapor retarder must be adequately sealed in order to provide a continuous membrane to resist the passage of water vapor. D. Building ventilation, whether by gravity ridge vent, power-operated fans, or other means, contributes significantly to reduced condensation. The movement of air to the outside of the building reduces the interior level of vapor pressure. On the buildings that have an attic space or are being retrofitted with metal roofing systems, vents should be placed at both the eave and peak of the roof in order to prevent a buildup of moisture (humidity) in the attic space. Contact your local building code official or an engineer on proper ventilation practices for you area. Cutting: Everlast recommends the use of tin snips or a "nibbler" type electric tool to field cutting metal panels. Cutting metal panels may create metal shavings. A. These shavings and/or chips must be removed immediately from the panel surface. ailure to remove such shavings or chips may cause staining and/or rust on the panel.. Any such surface damage will void the warranty. B. or your protection goggles should be worn when cutting metal panels and flashing. * This same principle applies when driving steel fasteners (see pages LG07 & LG08) LG-06
9 Coverage/Overlap and Screw/Nail Pattern of Everlast II COVERAGE OVERLAP Siphon Groove Woodscrew Roof Structure SCREW PATTERN NAIL PATTERN *Note - minimum of 1" fastener penetration is recommended LG-07
10 Coverage/Overlap and Screw/Nail Pattern of Everdrain COVERAGE OVERLAP Siphon Groove Roof Structure Wood Screw SCREW PATTERN NAIL PATTERN LG-08
11 Post rame Vented Universal Ridge Ridge astener Ridge Vent Ridge Cap Vapor Barrier 01 Universal Ridge TLURC1xx LG-09
12 Post rame Rake & Corner Post astener Girt astener 02 Rake & Corner TLRC2xxxx LG-10
13 Post rame Base Angle Skirt Board Inside Closure astener 03 Base Angle TLBA3xx LG-11
14 Post rame ascia Trim Inside Closure Roof astener Purlin astener Outside Closure Roof Truss Top Plate Post astener 04 ascia Trim TLT4xx LG-12
15 Post rame Gable Trim Purlin End Rafter Outside Closure 05 Gable Trim TLGT5xx LG-13
16 Post rame J Channel Door Jamb Door Girt Door Stop 'J' Channel astener 06 J Channel TLJC6xx LG-14
17 Post rame Double Angle Girt astener Inside Closure astener Butyl Tape Outside Closure 07 Double Angle TLDA7xx LG-15
18 Post rame Universal Sidewall Girt Inside Closure astener Butyl Tape astener Purlin Sloping Rafter 08 Universal Sidewall TLUS8xx LG-16
19 Post rame Drip Cap astener Inside Closure Window Unit 09 Drip Cap TLDC9xx LG-17
20 Post rame Post Trim Door Jamb Door Girt astener Door Stop astener 'J' Channel 10 Post Trim TLPT10xxxx LG-18
21 Post rame Universal Endwall Inside Closure astener Girt Butyl Tape astener Butyl Tape Outside Closure Purlin 11 Universal Endwall TLUE11xx LG-19
22 Post rame & J Trim astener Inside Closure acia Board Post Trim Soffit astener Wall Structure 12 & J Trim TLJ12xx LG-20
23 Post rame Inside Corner Girt astener Post astener Girt 13 Inside Corner TLIC13xx LG-21
24 Post rame Overhead Door Door Header Door Stops Man Door Overhead Door 14 Overhead Door TLODT14xx LG-22
25 Post rame Track Cover Cannonball M astener Girt 15 Track Cover Cannonball M TLCT15xx LG-23
26 Post rame Drip Edge EL astener Inside Closure Butyl Tape Drip Edge acia Board Soffit Post Trim 60 Drip Edge TL6.560xx LG-24
27 Post rame ascia & Soffit astener Butyl Tape Inside Closure astener acia Board astener Soffit Girt 17 ascia & Soffit TLS17xx LG-25
28 Post rame ormed Valley Valley Closure Vapor Barrier ormed Valley Solid Roof Structure 19 ormed Valley TLV19xx LG-26
29 Post rame Notched Endwall EL astener Inside Closure Notched to fit panel profile Girt Outside Closure Purlin Butyl Tape Top & Bottom of Closure 32 Notched Endwall EL TLNEEL32xx LG-27
30 Notes
31
32 10 Enterprise Court Lebanon, PA Office: ax: P.O. Box 278, 81 South High St. Bridgton, ME Office: ax: N 050 E Howe, IN Office: ax:
ABSeam Panel Overview and Installation Instructions
82 Garden Spot Road Ephrata, PA 17522 717-445-6885 35 Ridge Road Newville, PA 17241 717-776-5951 ABSeam Panel Overview and Installation Instructions Applications: The ABSeam panel is an architectural panel
BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra 2000. Includes:
BRIDGE & SUPPLY COMPANY Installation Guide Ultra 2000 Includes: Ultra 2000 Installation Guide Stock Trim Profiles Ultra 2000 Trim Installation Guide Page 2 Table of Contents Ultra 2000 Profile, Colors
General Instructions and Guidelines
General Instructions and Guidelines Building Design and Construction To ensure adequate performance and longevity, protect metal panels from potentially corrosive situations and materials. When treated
Residential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels
INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels Grand Rib-3 / Multi-Purpose / Classic Rib Grand Rib-3 / Multi-Purpose / & Classic Rib Grand Rib 3 panels are a strong,
Installation Manual for STANDING SEAM ROOFING
Installation Manual for STANDING SEAM ROOFING Absolute Steel Toll Free 877-833-3237 / Phone 480-768-1618 / Fax 480-768-1514 www.metalroofingsource.com Standing Seam features approximately one-inch high
Screw Patterns Roof & Walls 403-279-2766 TR-36 MD-36 TSM-32. PBR-Panel
Screw Patterns Roof & Walls Overlap Underlap ¾ 9 TR-36 36 5/8 6 MD-36 36 ½ 8 TSM-32 32 1¼ 12 PBR-Panel 36 Bottom Edge Screw Pattern apply to every profile except for MD36 (1 screw beside every rib) High
Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..
Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions
Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions All questions and concerns please call 904-696-9700 Discount Direct Metal Roofing Plus Rib metal roofing panels are a strong,
Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Standing Seam
Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME MATTERHORN Standing Seam System Components Placement G F J K I A. Standing Seam Panel B. Valley Cleat/Sidewall Counter Flashing D G B C A
METAL ROOFING INSTALLATION GUIDE
METAL ROOFING INSTALLATION GUIDE MIGHTY-RIB PBR (R-Panel) Regardless of whether your roofing project is a new installation or a re-roof, and whether your building is residential, commercial or agricultural,
VERTICAL LOCK Table of Contents
Table of Contents TABLE OF CONTENTS Vertical Lock Product Data Sheet... 2 Vertical Lock Engineering Data... 3 General Information... 6 Material Testing... 7 Panel Overview... 8 Handling Material & Storage
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
Product Catalog. Extreme Roofing, Inc. 2680 Rt. 982 Mammoth, PA 724.838.7695 www.extremeroofinginc.com
2012 Product Catalog Extreme Roofing, Inc. 2680 Rt. 982 Mammoth, PA 724.838.7695 www.extremeroofinginc.com 2 PH. 724.838.7695 Email. [email protected] Website. www.extremeroofinginc.com Fax.
Shingle Installation Guide
Shingle Installation Guide Getting Started Dedicated to improving the environment, NewTech manufactures roofing tiles that are composed of up to 90% recycled post-industrial plastic. The manufacture of
4572 N Old US 31, Rochester, IN 46975 Toll Free: 877-889-7802 Fax: 574-223-7846 www.ramcosupply.com DETAIL MANUAL. and guide to Ramco Supply products
4572 N Old US 31, Rochester, IN 46975 DETAIL MANUAL and guide to Ramco Supply products Metal Roofing and Siding Panels & Accessories 1 4572 N Old US 31, Rochester, IN 46975 Ramco Supply s RAM Roofing Panels
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide
Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
Retrofitting an Insulated Cold Roof
Retrofitting an Insulated Cold Roof As a metal-roofing contractor in the Upper Peninsula of Michigan, I am frequently asked to fix roof leaks that have less to do with roofing than with the way poorly
Metal Building Systems Installation and Flashings & Details Guide. Table of Contents
Table of Contents Section Page Notes to Designer/User..................1-2 Map of Typical Roof Conditions............3 Fastener Placement.......................4 Fastener Selection........................5
Preformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Section Page Section Page
Western States Western Rib Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer / Installers..1 Fastener Placement and Selection.2-3 Key
September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901
September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections
and Siding Effective Date 12/08 1
Application Manual for Metal Roofing and Siding Effective Date 2/08 Table of Contents General Information... 4 Required Tools... 4 Getting Started... 5 Important Notes... 6 Safety Precautions... 7 Panel
Chapter 9: INSTALLING ROOFING
9.1 LEAK BARRIER (ICE AND WATER SHIELD) 9.2 SHINGLE UNDERLAYMENT 9.3 INSTALLING GUTTER APRON AND GABLE D-EDGE 9.4 INSTALLING SHINGLES 9.5 RIDGE VENT AND CAP Tools needed by each volunteer: Hammer (16 oz.
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
DETAIL MANUAL. for Standing Seam. 2308 East 23rd Street Chattanooga, TN 37407. 1652 South Lee Hwy. Cleveland, TN 37311
DETAIL MANUAL for Standing Seam 1652 South Lee Hwy. Cleveland, TN 37311 2308 East 23rd Street Chattanooga, TN 37407 Best Buy Metals Standing Seam Roofing Panels Fig. 2 Standing Seam Panel Has 1 high nail-strip
SHINGLE APPLICATION GUIDE
SHINGLE APPLICATION GUIDE CONTENTS 01. General conditions 01. Material requirements 02. Terms 07. Estimating shingle requirements 08. Roof preparation 10.Shingle application E version 2006 GENERAL CONDITIONS
PBR & R Panel. Table of Contents
Table of Contents Important Information Installation Information Technical Information Trims and Flashings Illustration Roofing Installation Details Eave Flashing (EF-3) Eave Flashing (EF-7) Preformed
Best Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.
STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS
ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the
CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000
CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000 Details and Installation Guide October 2013 All information, descriptions and dimensions in this manual are current at the time of printing. As always, Custom-Bilt
INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS
2009 Pella Corporation INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS Part Number: 80WH0100 Installation Instructions for Typical Wood Frame Construction.
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read
INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW
Vinyl Windows and Doors Manufactured by Pella Corporation INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW Lea las instrucciones en español en el reverso.
PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS
Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
PANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,
Barewood Octagon and Elongated Windows Installation Instructions
Step-by-step instructions to a beautiful window. Measuring and Installation of your new window from Century Specialty Windows couldn't be easier with our step-by-step instructions. Quality, function and
foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
Directions For Applying Malarkey Laminate Shingles
S Laminate Shingle Instructions 1 Directions For Applying Malarkey Laminate Shingles GENERAL INSTRUCTIONS Install Malarkey laminate shingles according to building code and local amendments. To qualify
COMMERCIAL BUILDINGS. Quality Buildings Since 1983
COMMERCIAL BUILDINGS Quality Buildings Since 1983 Quality Buildings Since 1983 We are very proud of the buildings we construct Letter from the Owner: We appreciate your interest in a PDQ Building. I trust
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
Larry Haight's Residential Roofing Co, Inc 15203 NE 95th Street Redmond, Washington Phone: (425) 881-9771 Fax: (425) 869-1010
Larry Haight's Residential Roofing Co, Inc 15203 NE 95th Street Redmond, Washington Phone: (425) 881-9771 Fax: (425) 869-1010 Custom bid generated for: Job site address: Lake Villas Condominium Attention:
CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application 9 - 1 -
CONTENTS General conditions Material requirements 3 Terms 4 Estimating shingle requirements 4 Roof preparation 6 Shingle application 9 Shingle Shingle application application guide guide - - b a 3a 3b
SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010
Best Barns USA Assembly Book Revised November 29, 2010 SAMPLE INSTRUCTIONS the Denver 12'x 12' or 12'x16' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775
STEEL BUILDINGS RECOMMENDED INSTALLATION GUIDE
STEEL BUILDINGS RECOMMENDED INSTALLATION GUIDE 3 TO 30 METRE SPAN TILT UP METHOD SUPPLIED BY: Last update 8 December 2010 2010 FBHS (Aust) Pty Limited FBHS (Aust) Pty Limited ABN 83 126 232 504 trading
!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
Plans will call for one of two soffit/fascia details:
Plans will call for one of two soffit/fascia details: Ventilated vinyl soffit with bent aluminum fascia OR Ventilated LP Smartside soffit panels with 1x6 rabbeted fascia First, let s talk terminology:
SECTION 07400 STANDING SEAM METAL ROOF
SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and
Tundra Series Windows January 2016
Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing
VAIL Metal Shingles. Application Instructions. Custom-Bilt Metals 13940 Magnolia Ave. Chino, CA 91710
VAIL Metal Shingles Application Instructions 13940 Magnolia Ave. Chino, CA 91710 VAIL Metal Shingles Application Instructions When installing or walking on VAIL Metal Shingles: 1. OSHA fall protection
RESIDENTIAL METAL BUILDING COMPONENTS
3 3 BASIC EAVE UNIVERSAL TRIM * RT - 100 10 6.7500 4.47 2" VALLEY RT - 100 10 6.7500 4.47 8 3 1 8 3 WALL - ROOF & Open/ RT - 100 10 6.7500 4.47 3 Open TRANSITION & Open/ RT - 100 10 6.7500 4.47 3 9 1 Hilco
Snap-Loc. Installation Guide
Snap-Loc Installation Guide IMPORTANT INFORMATION THE APPLICATION AND DETAIL DRAWINGS IN THIS MANUAL ARE STRICTLY FOR ILLUSTRATION PURPOSES AND MAY NOT BE APPLICABLE TO ALL BUILDING DESIGNS OR PRODUCT
METAL ROOFING SYSTEM ORDERING & INSTALLATION SELF HELP GUIDE. Fabral, Inc 1
METAL ROOFING SYSTEM ORDERING & INSTALLATION SELF HELP GUIDE Due to product improvements, changes and other factors, Fabral reserves the right to change or delete information herein without prior notice
Basement Window Installation Guide Hopper and Sliding
Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,
PRO-PANEL II. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information
Table of ontents Product Page No. Product Page No. Panel Information Profile... PPP-2 Panel Overview... PPP-2 Flashing Profiles Eave (Direct Fasten)... PPP-3 leat... PPP-3 Box Gutter... PPP-3 Box Gutter
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin americancraftsmanwindows.com Project Requirements: Failure to follow these instructions may void product
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
GreenGuard Housewrap Installation Guide
000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be
G VYCOR DECK PROTECTOR
G VYCOR DECK PROTECTOR Self-Adhered Flashing Contractor s Guide DECKS AND DETAIL AREAS For longer lasting decks, install Grace Vycor Deck Protector. FROM THE MAKERS OF G Ice & Water Shield What Self-Adhered
INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
Prior to ordering and installing materials, all dimensions should be verified by field measurements.
Important Information The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. All projects
Classic Products, Inc. ClickLock Standing Seam Installation Manual
Classic Products, Inc. ClickLock Standing Seam Installation Manual Classic Products, Inc. 8510 Industry Park Drive Piqua, OH 45356 800.543.8938 Table of Contents page Introduction 1. 1 Starter. 2. 1 Panels.
POST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
Standing Seam Roof Systems
Standing Seam Roof Systems REAL PEOPLE. REAL PRODUCTS. REAL SOLUTIONS. www.a-s.com Building Benefits You Can Expect From A&S Materials Standing Seam roof panels weigh a relatively modest 11/2 pounds per
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements
SL150 Standing Seam. Installation Manual. (formerly CSL) Toll-Free (888) MTL-ROOF. PO Box 229 Fayetteville, NC 28302. www.unionmetalroofing.
SL150 Standing Seam (formerly SL) Installation Manual PO Box 229 Fayetteville, N 28302.. www.unionmetalroofing.com Toll-Free (888) MTL-ROOF Rev. 2/09 SL PANEL IMPORTANT NOTIE This manual contains suggestions
The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems
The Butler MR-24 Standing Seam Roof Difference A comparison between metal roof systems Roof Systems Necessities Weathertight (don t leak!) Low maintenance Weathertightness Roof clips, seams, panel alignment
Active and Passive Sash Replacement
for Andersen Gliding Windows Read all instructions carefully before attempting this procedure. If you have any questions about your ability to complete the procedure, call Andersen at 1-888-888-7020 for
GUIDELINE SPECIFICATIONS
GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced
HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX
Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
IF YOU NEED A POLE BARN OR DIY KIT CALL NOW AND LETS MAKE A DEAL
IF YOU NEED A POLE BARN OR DIY KIT CALL NOW AND LETS MAKE A DEAL Check out our Affordable Selection of DIY Pole Barn kit sizes and prices below. We offer a complete DIY pole barn kit plus independent experienced
Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof
ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find
Minimizing Water Intrusion Through Roof Vents in High-Wind Regions
Minimizing Water Intrusion Through Roof Vents in High-Wind Regions http://www.fema.gov HURRICANE IKE RECOVERY ADVISORY Purpose: To recommend practices for minimizing water intrusion through roof vent systems
INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast
CONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
CONDENSATION IN REFRIDGERATED BUILDINGS
CONDENSATION IN REFRIDGERATED BUILDINGS By: Steve Salisbury Nov. 10, 2010 (revised Nov. 14, 2013) Introduction The following discussion reviews the basic causes of condensation in refrigerated buildings
Condensation Fact Sheet METAL BUILDING MANUFACTURERS ASSOCIATION
Condensation Fact Sheet METAL BUILDING MANUFACTURERS ASSOCIATION The Condensation Process Condensation occurs when warmer moist air comes in contact with cold surfaces such as framing members, windows
We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
SL-16. Concealed Fastener System. This booklet includes: Trims and Accessories Design and Installation Information
SL-16 Concealed Fastener System This booklet includes: Trims and Accessories Design and Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF ANY
SECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
Brick Veneer Construction
Brick Veneer Construction Check list of suggested tools & support items Claw hammer Tape measure 3/4" [19 or 20] Wood chisel Wood or plastic shims Pry bar Utility knife Caulking and caulking gun Power
CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.
CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front
Commercial And Industrial Steel Buildings
Commercial And Industrial Steel Buildings Arco Building Systems, Inc. Since 1979 Arco has been providing the highest quality steel buildings to contractors and owners throughout the United States. Leadership
Chapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
THE USE OF STEEL BUILDING PANELS FOR ANIMAL CONFINEMENT
BACKGROUND Technical TSB 4.1 Bulletin Construction THE USE OF STEEL BUILDING PANELS FOR ANIMAL CONFINEMENT BACKGROUND TBP 2005.2 This Technical Bulletin is intended to assist users in the design and maintenance
GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.
GUIDE SPECIFICATION Manufacturer: DECRA Roofing Systems A Fletcher Building Company 1230 Railroad Street Corona, CA 92882 951-272-8180 phone 951-272-4476 facsimile www.decra.com SECTION 07314 [07 31 14]
We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
Shelterguard Metal Roofing System Ordering & Installation Guide
Shelterguard Metal Roofing System Ordering & Installation Guide Specifications contained herein subject to change without notice or obligation to make changes in products previously purchased. Shelterguard
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS
AC TOPSEAL SELF-ADHERED, GRANULAR SURFACED, SINGLE PLY, LOW SLOPE ROLLED ROOFING 3 X 33.3 = 100 SQ. FT. 10 YEAR MATERIAL LIMITED WARRANTY For Use on Porches / Sheds / Utility Buildings / Accessory Buildings
application instructions