GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

Size: px
Start display at page:

Download "GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps"

Transcription

1 GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps

2 Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance range, MAGNA (D), UPE(D) Product range Product range 5 Pump selection Pump size Operating conditions Communication Control mode Operating conditions Operating conditions 7 General recommendations 7 Liquid temperature 7 Ambient conditions 7 Maximum operating pressure 7 Minimum inlet pressure 7 Electrical data Sound pressure level Functions Functions 9 Control modes (factory setting) 1 AUTOADAPT 1 Proportional-pressure control 1 Additional control and operating modes 11 Constant-pressure control 11 Constant-curve duty 11 Max. or min. curve duty 11 Automatic night-time duty 11 Additional operating modes of twin-head pumps 11 Readings and settings on the pump 1 Communication 1 Digital input 13 Digital output 13 Analog input 1 Bus communication via GENIbus 1 Bus communication via LON 15 Functions of expansion modules 15 Construction Motor and electronic controller 1 Pump connections 1 Surface treatment 1 Material specification 17 Installation Mechanical installation 1 Electrical connection 1 Cables 1 Wiring diagram, single-phase 19 Wiring diagram, three-phase 19 Additional protection 19 Single-phase MAGNA Single-phase UPE Three-phase UPE(D) Examples of connections 1 Curve conditions Curve conditions Technical data Accessories Base plates 51 Adapter flanges 51 Counter flanges for pumps with cast-iron pump housing 51 Counter flanges for pumps with bronze pump housing 51 Blanking flanges 51 Union and valve kits 5 Union kits 5 Valve kits 5 Insulation kits 5 Expansion modules for MAGNA 5-, 3-, 5-1, 3-1, -1(D), GENI module 53 Relay module 5 Expansion modules for MAGNA (D) 5-, 5-, 3-1, -1, 5-1, GENI module 55 LON module 55 Expansion modules for single-phase UPE 5 Fault signal module MC / 5 Bus module MB / 5 R1 57 PMU 57 PCU 57 G1-LON interface 57 Prefilter 57 Order data MAGNA/UPE, cast iron 5 MAGNA, stainless steel 5 UPE, bronze 5 Further product documentation WebCAPS 59 WinCAPS 3

3 Product data MAGNA, UPE MAGNA and UPE The MAGNA/UPE ranges of circulator pumps are specially designed for heating systems up to 1 kw (Δt = C) and domestic hot-water systems (stainless-steel or bronze pump housing). Aicondition systems (+ C) up to 35 kw (Δt C) (MAGNA only). Duty range Data MAGNA UPE Maximum flow, Q 3 m 3 /h 9 m 3 /h Maximum head, 13 m 1.5 m Maximum system pressure 1 bar 1 bar Liquid temperature + C to +11 C +15 C to +11 C Fig. 1 MAGNA/UPE pump ranges Characteristic features AUTOADAPT proportional-pressure duty constant-pressure duty constant-curve duty max. or min. curve duty parallel connection of pumps with PMU no external motor protection required. Benefits low noise level safe selection simple installation low energy consumption, all MAGNA pumps are energy class "A" in addition to this, the AUTOADAPT function ensures energy savings for MAGNA pumps long life and no maintenance external control and monitoring enabled via expansion modules. GR Applications eating systems Main pump Mixing loops eating surfaces. Aircondition surfaces (MAGNA only) The MAGNA/UPE circulator pumps are designed for circulating liquids in heating systems with variable flows where it is desirable to optimise the setting of the pump duty point. The pumps are also suitable for domestic hot-water systems. To ensure correct operation, it is important that the sizing range of the system falls within the duty range of the pump. The MAGNA/UPE is especially suitable for installation in existing systems where the differential pressure of the pump is too high in periods with reduced flow demand. The pump is also suitable for new systems where automatic adjustment of pump head to actual flow demand is required without using expensive bypass valves or the like. Furthermore, the pump is suitable for application in systems with hot-water priority as an external contact can immediately force the pump to operate according to the max. curve. Pumped liquids Thin, clean, non-aggressive and non-explosive liquids, not containing any solid particles, fibres or mineral oil. If the pump is installed in a heating system, the water should meet the requirements of accepted standards on water quality in heating systems, e.g. the German standard VDI 35. In domestic hot-water systems, the pump should be used only for water with a degree of hardness lower than approx. 1 d. The pump must not be used for the transfer of inflammable liquids such as diesel oil and petrol. If the pump is not used during periods of frost, necessary steps must be taken to prevent frost bursts. Additives with a density and/or kinematic viscosity higher than those/ that of water will reduce the hydraulic performance. Whether a pump is suitable for a particular liquid, depends on a number of factors of which the most important are lime content, p value, temperature and content of solvents, oils, etc. 3

4 Product data MAGNA, UPE Type key MAGNA (D), UPE(D) Example UP E D -1 (F) (N) Type range UPE(D): MAGNA (D): Electronic control Twin-head pump Nominal diameter of suction and discharge ports (DN) Maximum head [dm] Flange connection N: Single-head pump housing of stainless steel B: Single-head pump housing of bronze A: Pump housing with air separator Port-to-port [mm] Performance range, MAGNA (D) and UPE(D) p [kpa] 13 1 MAGNA (D) MAGNA 5-1 MAGNA (D) -1 MAGNA 3-1 MAGNA 5-1 MAGNA (D) -1 MAGNA (D) 3-1 UPE(D) MAGNA (D) 5-1 MAGNA 3- MAGNA (D) 5- MAGNA (D) 5- UPE 5-, MAGNA 5- UPE 15-, 5-, 3- UPE(D) Q [m³/h] Q [l/s] TM Fig. Performance range

5 Product range MAGNA, UPE Product range Supply voltage Port-to-port length Pipe connection Flange connection 1 x 3- V 3 x -15 V [mm] 1" 1 1/" " PN /PN 1 PN PN 1 MAGNA 5-1 MAGNA 3-1 MAGNA MAGNA 3-1 (N) 1 MAGNA 3-1 F MAGNA (D) -1 F MAGNA 5-1 F UPE UPE 5- (B) 1 UPE 5- A 1 UPE 3-1 UPE 5- (B) 13 1 UPE 5- A 1 UPE 3-1 MAGNA (D) 3-1 F (N) MAGNA (D) -1 F (N) 5 MAGNA (D) 5- F (N) MAGNA (D) 5- F (N) 3 MAGNA (D) 5-1 F (N) MAGNA (D) 5-1 F (N) 3 UPE(D) -1 F (B) 3 UPE(D) 1- F (B) 5 5

6 Product range MAGNA, UPE Pump selection Pump size Selection of pump size should be based on required maximum flow and maximum head loss in the system. ead Duty point Operating conditions It should be checked whether the operating conditions are fulfilled, i.e. liquid temperature and ambient conditions minimum inlet pressure maximum operating pressure. Communication The requirements for external control or monitoring of the pump should be considered, such as access to speed control of pump or change of setpoint reading of pump data start/stop, fault indication or forced control to max. or min. curve. Note: The communication options depend on the pump type. Control mode In general, Grundfos recommends the factory setting which is suitable for most installations proportional-pressure control in systems with relatively great head losses constant-pressure control in systems with relatively small head losses. Fig. 3 Performance curve PMU BMS Flow PCU MAGNA/UPE UPE/MAGNA/TPE Fig. Building management system with four pumps in parallel controlled via a PMU and a PCU TM 331 TM 331

7 Operating conditions MAGNA, UPE Operating conditions General recommendations MAGNA/UPE Water in heating Water quality according to local standards systems such as the German standard VDI 35 Domestic hot water Degree of hardness up to 1 d Water containing glycol Viscosity 1 mm /s Liquid temperature Application Time MAGNA UPE General Domestic hotwater systems To avoid condensation in the terminal box and the stator, the liquid temperature must always be higher than the ambient temperature. Ambient conditions Short periods +11 C +11 C Continuously + C to +95 C +15 C to +95 C Continuously + C to + C +15 C to + C Ambient temperature during operation: C to + C Ambient temperature during storage/transport: C to + C Relative air humidity: Maximum 95 %. Maximum operating pressure 1 bar. Minimum inlet pressure The following relative minimum pressures must be available at the pump inlet during operation: Liquid temperature 75 C 9 C 95 C Inlet pressure [bar] MAGNA 5-, 5-1, 3-, 3-1, -1(D), UPE 15-, 5-, 5-, 3-, MAGNA (D) 3-1 F MAGNA (D) -1 F.15.5 MAGNA (D) 5- F MAGNA (D) 5-1 F..7 MAGNA (D) 5- F.15.5 MAGNA (D) 5-1 F.9 1. UPE(D) -1 F UPE(D) 1- F Note: Actual inlet pressure + pump pressure against a closed valve must be lower than the maximum permissible system pressure. 7

8 Operating conditions MAGNA, UPE Electrical data MAGNA/UPE Expansion module Sound pressure level Single-phase MAGNA 5-, 5-1, 3-, 3-1, -1(D), 5-1 Single-phase MAGNA (D) 3-1, -1, 5-, 5-1, 5-, 5-1 Single-phase UPE Enclosure class IP (IEC 5) IP (IEC 5) IP IP Insulation class F F External start/stop input Setpoint signals Signal output Bus input Supply voltage External potential-free switch. Screened cable. Maximum contact load: 5 V, 1 ma. External potential-free switch. Screened cable. Maximum contact load: 5 V, 1 ma. MC / MB / GENI module GENI module MC / MB / Internal potential-free changeover contact. Screened cable. Maximum contact load: 5 VAC, A. Minimum contact load: 5 VDC, 1 ma. GENI module LON via GENIbus and G1 modules 1 x 3- V 1 %/+ %, 5/ z, PE Internal potential-free changeover contact. Screened cable. Maximum contact load: 5 VAC, A. Minimum contact load: 5 VDC, 1 ma. GENI module LON module 1 x 3- V 1 %/+ %, 5/ z, PE The pump requires no external motor protection. MC / MB / Earth leakage current I leak < 3.5 ma The leakage currents are measured in accordance with EN EMC EN 1-3. Single-phase MAGNA 5-, 5-1, 3-, 3-1, -1(D), 5-1 Single-phase MAGNA (D) 3-1, -1, 5-, 5-1, 5-, x 3- V 1 %/+ %, 5 z, PE Single-phase UPE Three-phase UPE(D) External potential-free switch. Screened cable. Maximum contact load: 5 V,.7 ma. Max. and min. curve input External potential-free switch. Screened cable. Maximum contact load: 5 V,.7 ma. Input for analog -1 V signal External signal: -1 VDC. Maximum contact load: 1 ma. Internal potential-free changeover contact. Screened cable. Maximum contact load: 5 VAC, A. Minimum contact load: 5 VDC, 1 ma. Grundfos GENIbus protocol. Screened cable. Lead cross section:.5-1 mm. Maximum cable length: 1 m. 3 x -15 V ± 1 %, 5 z, PE Three-phase UPE(D) Sound pressure level 5 db(a) 5 db(a) 3 db(a) 5 db(a)

9 Functions MAGNA, UPE Functions Function incorporated. Expansion module required. G1-LON interface required. Not recommended for aircondition systems. Single-phase MAGNA 5-, 5-1, 3-, 3-1, -1(D), 5-1 Single-phase MAGNA (D) 3-1, -1, 5-, 5-1, 5-, 5-1 Single-phase UPE Three-phase UPE(D) Control modes (factory setting) AUTOADAPT Proportional-pressure control Additional control and operating modes Proportional-pressure control Constant-pressure control Constant-curve duty Max. or min. curve duty Automatic night-time duty Additional operating modes of twin-head pumps Alternating operation Standby operation Readings and settings on the pump Operating indication Flow indication Setpoint Control mode Fault indication Communication Wireless remote control, R1 External digital input/output External analog input Bus via GENIbus protocol, RS-5 Bus via LonTalk protocol, FTT 1 9

10 Functions MAGNA, UPE Control modes (factory setting) The pumps have been factory-set to AUTOADAPT (MAGNA). proportional-pressure control (UPE). The setpoint is factory-set to half of the maximum pump head. The factory setting is suitable for most installations. AUTOADAPT During operation, the pump automatically reduces the factory-set setpoint and adjusts it to the actual system characteristic. max. fac. auto_min Fig. AUTOADAPT A1 set1 A 3 A set Proportional-pressure control The pump head is changed continuously in accordance with the flow demand in the system. The head against a closed valve is half the setpoint. Q TM Fig. 5 AUTOADAPT control Note: Manual setting of the setpoint is not possible. When the control mode AUTOADAPT has been activated, the pump will start at set1, corresponding to 5 % of its maximum head, and then adjust its performance to A 1, see fig.. When the pump registers a lower pressure on the max. curve, A, the AUTOADAPT function automatically selects a correspondingly lower control curve, set. If the radiator valves close, the pump adjusts its performance to A 3. Q TM 9 set set Fig. 7 Proportional-pressure control The proportional-pressure control is recommended in systems with relatively great head losses. Q TM 995 A 1 : A : A 3 : set1 : set : Original duty point. Lower registered pressure on the max. curve. New duty point after AUTOADAPT control. Original setpoint setting. New setpoint after AUTOADAPT control. fac. : MAGNA xx-: 3.5 m. MAGNA xx-1: 5.5 m. auto_min : A fixed value of 1.5 m. The AUTOADAPT control mode is a form of proportionalpressure control where the control curves have a fixed origin, auto_min. The AUTOADAPT control mode is developed specificly for heating applications and not recommended for aircondition systems. 1

11 Functions MAGNA, UPE Additional control and operating modes Grundfos offers additional control and operating modes to meet specific demands. The functions available depend on the pump type and the expansion module chosen, see overview of functions on page 9. Constant-pressure control The pump head is kept constant, independent of the water requirement. Fig. Constant-pressure control The constant-pressure control is recommended in systems with relatively small head losses. Constant-curve duty Requires the use of an R1 remote control. The pump can be set to operate according to a constant curve like an uncontrolled pump. If an external controller is installed, the pump is able to change from one constant curve to another, depending on the value of the external signal. set Q TM Max. or min. curve duty The pump can be set to operate according to the max. or min. curve, like an uncontrolled pump. Min. Fig. 1 Max. or min. curves Max. The max. curve mode can be used in periods in which a maximum flow is required. This operating mode is for instance suitable for hot-water priority. The min. curve mode can be used in periods in which a minimum flow is required. This operating mode is for instance suitable for manual night-time duty. Automatic night-time duty When automatic night-time duty has been selected, the pump will change automatically between normal duty and night-time duty. Changeover between normal duty and night-time duty takes place as a result of the flowpipe temperature measured by an integrated temperature sensor. The automatic changeover to night-time duty takes place when the temperature sensor registers a flowpipe temperature drop of more than 1-15 C within approx. hours. The required temperature drop is a minimum of.1 C/min. Changeover to normal duty takes place without a time lag when the temperature has increased by approx. 1 C. Q TM Max. Min. Q Fig. 9 Constant-curve duty TM Additional operating modes of twin-head pumps The following operating modes are available for twinhead pumps: Alternating operation Pump operation alternates every hours. If the duty pump stops due to a fault, the other pump will start. Standby operation One pump is operating continuously. In order to prevent seizing-up, the other pump will start at a fixed frequency (every hours) and run for a short period. If the duty pump stops due to a fault, the other pump will start. 11

12 Functions MAGNA, UPE Readings and settings on the pump The control panel on the pump control box/terminal box incorporates the basic functions for readings and settings. 1 Communication Depending on pump type, MAGNA/UPE enables communication via wireless remote control, R1 connection to an external alarm device digital input/output analog input. 5 STOP m3/h 1% EXT Fig. 11 MAGNA control panel Pos. Description 1 Buttons for setting of head 3 Indicator lights for operating and fault indication and symbol for indication of external control Button for selection of control mode: AUTOADAPT, proportional pressure, constant pressure and automatic night-time duty Light symbols for indication of control mode and night-time duty 5 Light fields for indication of head, flow and operating mode Pos. Fig. 1 UPE control panel Description 3 AUTO ADAPT Buttons for start/stop of the pump, setting of setpoint, control 1 mode, min. and max. curve Light fields for indication of control mode and setpoint 3 Indicator lights for operating and fault indication 1 3 TM TM 31 3 Fig. 13 R1 remote control MAGNA/UPE is designed for wireless communication with the Grundfos R1 remote control. The R1 offers additional possibilities of setting and status displays for the pump. The R1 can be used for the following functions: reading of operating data reading of fault indications setting of control mode setting of.1 m head increments selection of external setpoint signal allocation of pump number making it possible to distinguish between pumps in connection with parallel operation via bus selection of function for digital input. The MAGNA/UPE has various inputs and outputs for external signals for forced-control functions. Some functions may require an expansion module. Grundfos GENIbus TM 9 TM3 3 1 Fig. 1 MAGNA with expansion module 1

13 Functions MAGNA, UPE Digital input External start/stop The pump can be started or stopped via the digital input. Start/stop Normal duty Stop External forced max. or min curve The pump can be forced to operate on the max. or min curve via the digital input. Max. curve Min. curve Normal duty Max. curve Normal duty Min. curve The function of the digital input is selected with the R1 remote control. Q Q Q Q Q Q Digital output The pump incorporates a signal relay with a potentialfree changeover contact for external fault indication. MAGNA 5-, 5-1, 3-, 3-1, -1, 5-1 The function of the signal relay can be changed from "Fault" to "Operating" or "Ready" mode with the R1. These pumps require expansion modules. The functions of the signal relay are as shown in the table below: Signal relay Fault signal 1 3 NC NO C 1 3 NC NO C 1 3 NC NO C Not activated: The electricity supply has been switched off. The pump has not registered a fault. Activated: The pump has registered a fault. Signal relay Operating signal Not activated: The pump has been set to stop. 1 3 NC NO C The pump has registered a fault and is unable to 1 3 NC NO C run. 1 3 NC NO C Activated: The pump is running. The pump has registered a fault, but is able to run. Signal relay Ready signal Not activated: The pump has been set to stop. 1 3 NC NO C The pump has registered a fault and is unable to 1 3 NC NO C run. 1 3 NC NO C Activated: The pump is ready to run or is running. MAGNA 3-1, -1, 5-, 5-1, 5-, 5-1 The function of the signal relay can be changed from "Fault" to "Operating" mode with the R1. The functions of the signal relay are as shown in the table below: Signal relay Fault signal 1 3 NC NO C 1 3 NC NO C Not activated: The electricity supply has been switched off. The pump has not registered a fault. 1 3 NC NO C Activated: The pump has registered a fault. Signal relay Operating signal Not activated: The pump has been set to stop. 1 3 NC NO C The pump has registered a fault and is unable to 1 3 NC NO C run. 1 3 NC NO C Activated: The pump is running. The pump has registered a fault, but is able to run. 13

14 Functions MAGNA, UPE Analog input External analog control Requires an expansion module. Control of setpoint or speed via an external -1 V signal. Bus communication via GENIbus The bus enables control and monitoring of the pumps from a GRUNDFOS Pump Management System, to a building management system (BMS) or another external control system. m Max. curve Setpoint/constant curve Min. curve 1 3 Fig. 15 Example of -1 V control 9 1 The analog input enables the following control modes: In constant-curve mode, the pump is able to change from one constant curve to another depending on the value of the external signal. The internal controller is inactive in this mode. In pressure control mode, the setpoint can be set externally within the range from the setpoint to the min. curve. The internal controller is active in this mode. 5 At an input voltage lower than.5 V, the pump will operate according to the min. curve. 7 U V TM MAGNA/UPE Fig. 1 Example of single-pump operation Requires See section MAGNA GENI module Accessories UPE, single-phase MB / module UPE, three-phase BMS TM MAGNA/UPE TM Fig. 17 Example of pumps operating in parallel Requires See section MAGNA GENI module PMU or PCU UPE, single-phase MB / module PMU or PCU UPE, three-phase PMU or PCU Accessories 1

15 Functions MAGNA, UPE Bus communication via LON Via the bus input, the pump can be connected to a network based on LonWorks technology, and thus be linked to other units based on this communication standard. BMS GENI module LON module G1-LON MAGNA 5-, 3-, 5-1, 3-1, -1(D), 5-1 MAGNA (D) 5-, 5-, 3-1, -1, 5-1, 5-1 UPE, single-phase UPE, three-phase G1-LON Expansion module TM Fig. 1 Example of single-pump operation Functions of expansion modules Inputs/outputs incorporated With expansion module Function MAGNA 5-, 5-1, 3-, 3-1, -1, 5-1 MAGNA (D) 3-1, -1, 5-, 5-1, 5-, 5-1 Start/stop Signal relay UPE, single-phase Relay module GENI module GENI module LON module MC / MB / Start/stop Signal relay Start/stop Max. curve Min. curve -1 V analog input Twin-head pump control GENIbus Signal relay Max. curve Min. curve -1 V analog indput Twin-head pump control GENIbus LonTalk protocol, FTT1 Start/stop Max. curve Min. curve -1 V analog input Start/stop Max. curve Min. curve 15

16 Construction MAGNA, UPE The MAGNA/UPE is of the canned-rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. The pump is characterised by controller integrated in the terminal box control panel on the terminal box terminal box prepared for optional modules differential-pressure and temperature detection cast-iron, stainless-steel or bronze or pump housing twin-head versions air separator pump housing, types UPE 5- A and UPE 5- A no external motor protection required. Motor and electronic controller The single-phase MAGNA motor is a - or -pole, synchronous, permanent-magnet motor (PM motor). This motor type is characterised by higher efficiency than a conventional asynchronous squirrel-cage motor. Pump speed is controlled by an integrated frequency converter. The single-phase UPE motor is a -pole, asynchronous squirrel-cage motor with radio noise filter to VDE 75. The terminal box and the motor-pump unit have been tested in accordance with VDE 7. The terminal box incorporates a controller. The pump speed is calculated via a built-in induction coil on the stator winding. The three-phase UPE motor is a -pole, asynchronous squirrel-cage motor with integrated frequency converter. A differential-pressure and temperature sensor forms an integral unit. The sensor is located inside the pump housing in a channel between suction and discharge sides. Twin-head pumps have two sensors. Pump connections Threaded pump connections to ISO /1. Flange dimensions to ISO 75-/BS5. Surface treatment The pumps are wet-varnished. Colour: NCS-5R. 1

17 Construction MAGNA, UPE Material specification 1 MAGNA/UPE Pos. Component Material EN/DIN 1 Terminal box Aluminium/composite Stator housing Aluminium AlSi 1Cu O-rings EPDM rubber 3 Outer bearing ring Aluminium oxide Al O 3 Rotor can Stainless steel Shaft Stainless steel or tungsten carbide or aluminium oxide 5 Thrust bearing Carbon MY or 1.1 Bearing plate Stainless steel 1.31 Inner bearing ring 7 Impeller Pump housing 9 Differential-pressure and temperature sensor Aluminium oxide Al O 3 or silicium carbide SiO Stainless steel or composite Cast iron EN-GJL15/-/-5, bronze or stainless steel Composite PES Fig. MAGNA 3-1, -1, 5-, 5-1, 5- and TM TM Fig. 1 UPE 15-, 5-, 3-, 5- and 3-1 TM Fig. 19 MAGNA 5-, 5-1, 3-, 3-1, -1 and TM 15 3 Fig. UPE -1 and 1-17

18 Installation MAGNA, UPE Mechanical installation MAGNA/UPE is for indoor installation. The pump must be installed with horizontal motor shaft. The pump may be installed in horizontal as well as vertical pipes. Arrows on the pump housing indicate the liquid flow direction through the pump. The liquid flow direction can be horizontal or vertical, depending on the terminal box position. The terminal box can be turned to various positions, depending on pump type. This is described in the installation and operating instructions. The pump must be installed in such a way that strain from the pipework is not transferred to the pump housing. The pump may be suspended direct in the pipes, provided the pipework can support the pump. If not, the pump must be installed on a mounting bracket or base plate. To ensure cooling of motor and electronics, the following must be observed: Place the pump in such a way that sufficient cooling is ensured. The temperature of the cooling air must not exceed C. Electrical connection The electrical connection and protection should be carried out in accordance with local regulations. The pump must be connected to an external mains switch. The pump must always be correctly earthed. The pump requires no external motor protection. The motor incorporates thermal protection against slow overloading and blocking (IEC 3-11: TP 11). When the pump is switched on via the mains, the pump will start after approx. 5 seconds. Note: The number of starts and stops via the mains supply must not exceed times per hour. The pump mains connection must be made as shown in the diagrams on the following pages. Cables Use screened cables ( mm ) for external on/off switch, digital input, sensor and setpoint signals. All cables used must be heat-resistant up to at least +5 C. All cables used must be installed in accordance with EN -1. 1

19 Installation MAGNA, UPE Wiring diagram, single-phase External switch ELCB Max. 1 A/1 A TM Fig. 3 1 x 3- V 1 %/+ %, 5/ z Wiring diagram, three-phase External switch L1 L L3 PE ELCB Max. 1 A L1 L L3 TM 97 9 Fig. 3 x -15 V ±1 %, 5/ z Additional protection If the pump is connected to an electric installation where an earth-leakage circuit breaker (ELCB) is used as an additional protection, the earth-leakage circuit breaker must be marked with the following symbols. Single-phase The earth-leakage circuit breaker must trip out when earth fault currents with DC content (pulsating DC) occur. Three-phase The earth-leakage circuit breaker must trip out when earth fault currents with DC content (pulsating DC) and smooth DC earth fault currents occur. 19

20 Installation MAGNA, UPE Single-phase MAGNA Single-phase UPE L N 1 TM TM TM Fig. 7 Single-phase UPE mains connection Three-phase UPE(D) Signal output 1 3 Differential pressure and temperature sensor Mains connection 3 TM NCNO C L3 L L1 Fig. 5 MAGNA 5-, 5-1, 3-, 3-1, -1(D), 5-1, mains connection with Alpha power plug Start/stop Min. curve (night-time duty) Max. curve Analog -1 V input A Y B DC -1 V TM Mains connection L N Signal output 1 3 NC NO C Start/stop 7 Fig. MAGNA 3-1, -1, 5-1, 5-1, 5-, 5-, mains connection Note: If no external on/off switch is connected, the connection across terminals STOP and should be maintained. S T O P Potential-free relay input TM Fig. Three-phase UPE(D) mains connection Single-head pumps are connected as shown above. If no external on/off switch is connected, the connection across terminals 7 and should be maintained. If the -1 V input is used (terminals 11 and 1), there must be a connection across terminals 7 and 9 (input for min. curve must be closed). Twin-head pumps Both pumps must be connected to the mains. A possible external controller is to be connected to the master pump (terminals 7 to 1). If the twin-head pump is to be connected to a PMU or PCU, it must be set to singlepump operation. The bus connection between master and slave pumps can be removed. Both master and slave pumps must be connected to the bus system.

21 Installation MAGNA, UPE Examples of connections Connection to external controllers L N NC NO C S T O P Mains connection Operation Alarm Stop Start Dry-running protection TM Fig. 9 Example of MAGNA pump Connection to external controllers L N NC NO C S T O P A Y B X Q Z 1 V GENIbus Alarm Mains connection STOP 1 V Setpoint setting DC -1 V Stop Start Frost protection TM Fig. 3 Example of MAGNA pump with GENI module 1

22 Curve conditions MAGNA, UPE Curve conditions The guidelines below apply to the performance curves on pages 3 to 5: The bold parts of the curves show the recommended performance range. Test liquid: Airless water. All curves show average values and should not be used as guarantee curves. If a stated minimum performance is required, individual measurements must be made. MAGNA (D) and UPE(D) have been tested at C. The conversion between head and pressure [kpa] has been made for water at C (ρ = 93. kg/m 3 ). For liquids with other densities, e.g. hot water, the discharge pressure is proportional to the density. The pumps should not be used at a minimum flow rate lying outside the areas indicated by the bold-faced curves due to danger of pump overheating. Note: Within MAGNA's performance range, the constant- and proportional-pressure curves can be set in steps of 1 m head on the control panel and.1 m head with the R1.

23 Technical data MAGNA 5- MAGNA 5- p [kpa] [hp] Electrical data Q [m³/h] 5 m Proportional pressure m Q [m³/h] Q [l/s] Q [m³/h] 5 m Constant pressure 1 m Q [m³/h] Q [l/s] TM U n [V] P 1 I 1/1 [A] Min x 3- V Max. 5. TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 G Gross [m 3 ] MAGNA /

24 Technical data MAGNA 3- MAGNA 3- (N) p [kpa] [hp] Electrical data Q [m³/h] 5 m Proportional pressure Q [m³/h] Q [l/s] m Q [m³/h] 5 m Constant pressure Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 5- F is also available with stainless-steel housing, type N. 1 x 3- V Min. 1.9 Max m TM TM Dimensions and weights PN / PN 1 Dimensions [mm] Weight [kg] Ship. vol. [m 3 ] L1 B1 B B B B7 1 3 D1 G Gross MAGNA

25 Technical data MAGNA 5- F MAGNA 5- F p [kpa] [hp] Electrical data 1 1 Q [m³/h] Proportional pressure 5 m m 1 1 Q [m³/h] Q [l/s] 3 m m Q [m³/h] Constant pressure 5 m m 3 m m 1 1 Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 5- F is also available with stainless-steel Min housing, type N. 1 x 3- V Max. 1.7 TM D B 1 B5 D D1 L1 D5 B1 M L3 Rp 1/ B B B3 B7 D3 D3 TM Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA 5- F / /19 M

26 Technical data MAGNA 5- F MAGNA 5- F p [kpa] [hp] Electrical data 1 1 Q [m³/h] Proportional pressure 5 m m 3 m 1 1 Q [m³/h] Q [l/s] m Q [m³/h] Constant pressure 5 m m 3 m m 1 1 Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 5- F is also available with stainless-steel Min housing, type N. 1 x 3- V Max. 5. TM D B 1 B5 D D1 L1 D5 B1 M L3 Rp 1/ B B B3 B7 D3 D3 TM Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA 5- F / /19 M1.3

27 Technical data MAGNA 5-1 MAGNA 5-1 p [kpa] Proportional pressure 1 1 Constant pressure [hp] Electrical data Q [m³/h] 9 m m Q [m³/h] Q [l/s] Q [m³/h] 9 m 1 m Q [m³/h] Q [l/s] TM U n [V] P 1 I 1/1 [A] Min x 3- V Max TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 G Gross [m 3 ] MAGNA /

28 Technical data MAGNA 3-1 (N) MAGNA 3-1 (N) p [kpa] Proportional pressure 1 1 Constant pressure [hp] Electrical data 1 Q [m³/h] 9 m m 1 Q [m³/h] Q [l/s] Q [m³/h] 9 m 1 Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 3-1 is also available with stainless-steel Min. 1.1 housing, type N. 1 x 3- V Max m TM TM Dimensions and weights Dimensions [mm] Weights [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 G Gross [m 3 ] MAGNA 3-1 (N) (N).1

29 Technical data MAGNA 3-1 F MAGNA 3-1 F p [kpa] Proportional pressure 1 1 Constant pressure Electrical data [hp] Q [m³/h] m m 1 Q [m³/h] Q [l/s] Q [m³/h] 9 m 1 Q [m³/h] Q [l/s] 1 m TM U n [V] P 1 I 1/1 [A] Min x 3- V Max TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 D D3 D D5 PN Gross [m 3 ] MAGNA 3-1 F / /1..1 9

30 Technical data MAGNA -1 F MAGNA -1 F p [kpa] Proportional pressure 1 1 Constant pressure [hp] Electrical data Q [m³/h] 9 m m Q [m³/h] Q [l/s] Q [m³/h] 9 m 1 m Q [m³/h] Q [l/s] TM U n [V] P 1 I 1/1 [A] Min x 3- V Max TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 D D3 D D5 PN Gross [m 3 ] MAGNA -1 F / /

31 Technical data MAGNA 5-1 F MAGNA 5-1 F p [kpa] Proportional pressure 1 1 Constant pressure [hp] Electrical data 1 Q [m³/h] 9 m m 1 Q [m³/h] Q [l/s] Q [m³/h] 9 m 1 Q [m³/h] Q [l/s] 1 m TM U n [V] P 1 I 1/1 [A] Min x 3- V Max TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 D D3 D D5 PN Gross [m 3 ] MAGNA 5-1 F / /

32 Technical data MAGNA 3-1 F MAGNA 3-1 F p [kpa] 1 1 [hp] Electrical data Q [m³/h] 1 m m Proportional pressure m m Q [m³/h] Q [l/s] Q [m³/h] 1 m m Constant pressure m m Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 3-1 F is also available with stainless-steel Min housing, type N. 1 x 3- V Max TM D B 1 B5 D D1 B1 L1 D5 M L3 Rp 1/ B B B3 B7 D3 D3 TM Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA 3-1 F /1 1 1/19 M

33 Technical data MAGNA -1 F MAGNA -1 F p [kpa] 1 1 [hp] Electrical data Q [m³/h] 1 m m Proportional pressure m m Q [m³/h] Q [l/s] Q [m³/h] 1 m Constant pressure m m m Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA -1 F is also available with stainless-steel Min housing, type N. 1 x 3- V Max. 5. TM D B 1 B5 D D1 B1 L1 D5 M L3 Rp 1/ B B B3 B7 D3 D3 TM Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA -1 F / /19 M

34 Technical data MAGNA 5-1 F MAGNA 5-1 F p [kpa] 1 1 [hp] Electrical data 1 1 Q [m³/h] Proportional pressure 1 m m m m 1 1 Q [m³/h] Q [l/s] Q [m³/h] 1 m Constant pressure m m m 1 1 Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 5-1 F is also available with stainless-steel Min. 35. housing, type N. 1 x 3- V Max. 3.5 TM 1 3 D B 1 B5 D D1 B1 L1 D5 M L3 Rp 1/ B B B3 B7 D3 D3 TM Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. L1 L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross [m 3 ] MAGNA 5-1 F / /19 M1.3 3

35 Technical data MAGNA 5-1 F MAGNA 5-1 F p [kpa] 1 1 [hp] Electrical data Q [m³/h] 1 m Proportional pressure m Q [m³/h] 1 Q [l/s] m m Q [m³/h] 1 m Constant pressure m m Q [m³/h] 1 Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 5-1 F is also available with stainless-steel Min. 35. housing, type N. 1 x 3- V Max m TM 15 3 D B 1 B5 D D1 B1 L1 D5 M L3 Rp 1/ B B B3 B7 D3 D3 TM Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. L1 L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross [m 3 ] MAGNA 5-1 F / /19 M

36 Technical data UPE 15-, UPE 5-, UPE 3- UPE 15-, UPE 5-, UPE 3- p [kpa] 3 1 [hp] Q [m³/h] 3.5 m Proportional pressure 3 m. m 1. m Q [m³/h] 3.5 m Constant pressure.7 m 1. m 1. m Q [m³/h] Q [m³/h].... Q [l/s].... Q [l/s] Electrical data U n [V] P 1 I 1/1 [A] UPE 5- is also available with bronze housing, Min..1 type B. 1 x 3- V Max.. TM1 595 G B 3 L1 B1 B3 B TM 31 7 Dimensions and weights Dimensions [mm] Weights [kg] Ship. vol. L1 B1 B B3 B 3 G Net Gross [m 3 ] UPE UPE / UPE Weights of bronze versions are approx. 1 % higher. 3

37 Technical data UPE 5- A UPE 5- A p [kpa] 3 1 [hp] Q [m³/h] 3.5 m Proportional pressure 3 m. m 1. m m Constant pressure Q [m³/h].7 m 1. m 1. m Q [m³/h].... Q [l/s] Electrical data Q [m³/h].... Q [l/s] TM1 595 U n [V] P 1 I 1/1 [A] 1 x 3- V Min..1 Max.. G B 3 L1 B1 B3 B 1 TM 7 3 Dimensions and weights Dimensions [mm] Weights [kg] Ship. vol. L1 B1 B B3 B 1 3 G Net Gross [m 3 ] UPE 5- A /

38 Technical data UPE 5-, UPE 3- UPE 5-, UPE 3- p [kpa] 7 Proportional pressure 7 Constant pressure [hp] Q [m³/h] 5 m m 3 m m Q [m³/h] 5 m m 3 m 1 m m Q [m³/h] Q [m³/h]..... Q [l/s]..... Q [l/s] Electrical data U n [V] P 1 I 1/1 [A] UPE 5- is also available with bronze housing, Min.. type B. 1 x 3- V Max. 1. TM 55 G B 3 L1 B1 B3 B TM 31 7 Dimensions and weights Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 B1 B B3 B 3 G Net Gross /...1 UPE / UPE Weights of bronze versions are approx. 1 % higher. 3

39 Technical data UPE 5- A UPE 5- A p [kpa] 7 Proportional pressure 7 Constant pressure [hp] Q [m³/h] 5 m m 3 m m Q [m³/h] 5 m m 3 m 1 m m Q [m³/h]..... Q [l/s] Electrical data Q [m³/h]..... Q [l/s] TM 55 U n [V] P 1 I 1/1 [A] 1 x 3- V Min.. Max. 1. G B 3 L1 B1 B3 B 1 TM 7 3 Dimensions and weights Dimensions [mm] Weights [kg] Ship. vol. L1 B1 B B3 B 1 3 G Net Gross [m 3 ] UPE 5- A /

40 Technical data UPE 1- F UPE 1- F p [kpa] 5 5 Proportional pressure 5 Constant pressure [hp] Q [m³/h]. m 3. m.5 m. m Q [m³/h] 5. m 3.5 m.5 m 1. m.. Electrical data Q [m³/h] Q [l/s] Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] UPE 1- F is also available with bronze housing, Min type B. 3 x -15 V Max TM 91 B 1 3 B7 D D3 D1 L1 D Rp 1/ B1 M B B B5 B9 L3 D5 PN PN 1 TM 97 5 Dimensions and weights Dimensions [mm] Weights [kg] Ship. vol. L1 L L3 B1 B B B5 B7 B B9 1 3 D1 D D3 D D5 M Net Gross [m 3 ] UPE 1- F (PN ) M UPE 1- F (PN 1) M Weights of bronze versions are approx. 1 % higher.

41 Technical data UPE -1 F UPE -1 F p [kpa] Proportional pressure 1 1 Constant pressure [hp] Electrical data Q [m³/h] 7.5 m. m 1. m.5 m Q [m³/h] 1 1 Q [l/s] Q [m³/h] m m 1 m m Q [m³/h] 1 1 Q [l/s] U n [V] P 1 I 1/1 [A] UPE -1 F is also available with bronze housing, Min type B. 3 x -15 V Max TM 99 B 1 3 B7 D D3 D1 L1 D Rp 1/ B1 M B B B5 B9 L3 D5 PN PN 1 TM 97 5 Dimensions and weights Dimensions [mm] Weights [kg] Ship. vol. L1 L L3 B1 B B B5 B7 B B9 1 3 D1 D D3 D D5 M Net Gross [m 3 ] UPE -1 F (PN ) M UPE -1 F (PN 1) M Weights of bronze versions are approx. 1 % higher. 1

42 Technical data MAGNA D -1 F MAGNA D -1 F p [kpa] Proportional pressure 1 1 Constant pressure Q [m³/h] Q [m³/h] [hp] m m m Q [m³/h] Q [l/s] m Q [m³/h] Q [l/s] TM Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min. 1.9 pump head. 1 x 3- V Max TM Dimensions and weights PN / PN 1 Dimensions [mm] Weight [kg] Ship. vol. [m 3 ] L1 B1 B B3 B B5 1 3 D1 D D3 D D5 PN Gross MAGNA D -1 F / /

43 Technical data MAGNA D 5- F MAGNA D 5- F p [kpa] 7 Proportional pressure 7 Constant pressure Q [m³/h] Q [m³/h] [hp] m m 1 1 Q [m³/h] Q [l/s] 3 m m m m 3 m m 1 1 Q [m³/h] Q [l/s] TM 191 Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min pump head. 1 x 3- V Max. 1.7 B1 B3 1 3 B B7 B D D D1 L L1 D5 Rp1/ L3 B B5 M D3 D3 TM 79 1 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L L3 B1 B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA D 5- F / /19 M

44 Technical data MAGNA D 5- F MAGNA D 5- F p [kpa] 7 Proportional pressure 7 Constant pressure Q [m³/h] Q [m³/h] [hp] m m 3 m 1 1 Q [m³/h] Q [l/s] m m m 3 m m 1 1 Q [m³/h] Q [l/s] TM 1913 Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min pump head. 1 x 3- V Max. 5. B1 B3 1 3 B B7 B D D D1 L L1 D5 Rp1/ L3 B B5 M D3 D3 TM 79 1 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L L3 B1 B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA D 5- F / /19 M1 9.13

45 Technical data MAGNA D 3-1 F MAGNA D 3-1 F p [kpa] Proportional pressure 1 1 Constant pressure Q [m³/h] Q [m³/h] [hp] m m m m Q [m³/h] Q [l/s] m m m m Q [m³/h] Q [l/s] TM 191 Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min pump head. 1 x 3- V Max B1 B3 1 3 B B7 B D D D1 D5 Rp1/ L L3 B B5 M L1 D3 D3 TM 79 1 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L L3 B1 B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA-D 3-1 F /1 1 1/19 M

46 Technical data MAGNA D -1 F MAGNA D -1 F p [kpa] Proportional pressure 1 1 Constant pressure Q [m³/h] Q [m³/h] [hp] m m m m Q [m³/h] Q [l/s] m m m m Q [m³/h] Q [l/s] TM 1911 Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min pump head. 1 x 3- V Max. 5. B1 B3 1 3 B B7 B D D D1 L L1 D5 Rp1/ L3 B B5 M D3 D3 TM 79 1 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L L3 B1 B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA D -1 F / /19 M1 5.57

47 Technical data MAGNA D 5-1 F MAGNA D 5-1 F p [kpa] Proportional pressure 1 1 Constant pressure Q [m³/h] 1 1 Q [m³/h] [hp] m m m m 1 1 Q [m³/h] Q [l/s] 1 1 m m m m 1 1 Q [m³/h] Q [l/s] TM 1 Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min. 35. pump head. 1 x 3- V Max. 3.5 B1 B3 1 3 B B7 B D D D1 L L1 D5 Rp1/ L3 B B5 M D3 D3 TM 79 1 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L L3 B1 B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA D 5-1 F / /19 M

48 Technical data MAGNA D 5-1 F MAGNA D 5-1 F p [kpa] Proportional pressure 1 1 Constant pressure Q [m³/h] Q [m³/h] [hp] m m Q [m³/h] 1 Q [l/s] m m 1 1 m m m Q [m³/h] 1 Q [l/s] m TM 15 Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min. 35. pump head. 1 x 3- V Max B1 B3 1 3 B B7 B D D D1 L L1 D5 Rp1/ L3 B B5 M D3 D3 TM 79 1 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. L1 L L3 B1 B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross [m 3 ] MAGNA D 5-1 F / /19 M

49 Technical data UPED 1- F UPED 1- F p [kpa] 5 5 Proportional pressure 5 Constant pressure [hp] Q [m³/h]. m 3. m.5 m. m Q [m³/h] 5. m 3.5 m.5 m 1. m.. Electrical data Q [m³/h] Q [l/s] Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min pump head. 3 x -15 V Max TM 91 B3 1 3 B7 B B D D3 D1 L L1 D B Rp 1/ L3 B B5 M D5 PN PN 1 TM 95 5 Dimensions and weights Dimensions [mm] Weights [kg] Ship. vol. L1 L L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross [m 3 ] UPED 1- F (PN ) M UPED 1- F (PN 1) M

50 Technical data UPED -1 F UPED -1 F p [kpa] Proportional pressure 1 1 Constant pressure Q [m³/h] Q [m³/h] [hp] m. m. m.5 m 1 m m m m Q [m³/h] 1 1 Q [l/s] Q [m³/h] 1 1 Q [l/s] TM 99 Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min pump head. 3 x -15 V Max B3 1 3 B7 B B D D3 D1 L L1 D B Rp 1/ L3 B B5 M D5 PN PN 1 TM 95 5 Dimensions and weights Dimensions [mm] Weights [kg] Ship. vol. L1 L L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross [m 3 ] UPED -1 F (PN ) M UPED -1 F (PN 1) M

51 Accessories MAGNA, UPE Base plates Base plates including hexagon screws are available on request. MAGNA 5- F, 5- F MAGNA 3-1 F, 5-1 F MAGNA -1 F, 5-1 F MAGNA 3-1 FN, -1 FN MAGNA 5- FN, 5- FN MAGNA 5-1 FN, 5-1 FN xø1 xø1 1 Fig. 31 Base plate for MAGNA exagon screws Product number x M1 x mm 9535 x M1 x mm 531 xø1 exagon screws Product number UPE 1- F UPE -1 F x M1 x 3 mm xø TM Counter flanges for pumps with cast-iron pump housing Pressure stage Size Product number MAGNA, UPE(D) 3 PN 1 MAGNA, UPE(D) PN 1 PN 1 MAGNA, UPE(D) 5 PN 1 MAGNA, UPE(D) 5 PN 1 UPE(D) UPE(D) 1 PN PN 1 PN PN 1 Rp 1 1/ mm 5397 Rp 1 1/ mm 5397 One set consists of two flanges including gaskets and bolts. Counter flanges according to ISO Rp mm 59 Rp 1/ mm 559 Rp mm 5991 Rp 3 59 mm 591 Rp mm 5799 Rp mm 579 Counter flanges for pumps with bronze pump housing Pressure stage Size Product number UPE UPE 1 PN PN 1 Rp mm Rp mm 5911 PN Rp PN 1 Rp xø1 xø1 1 One set consists of two flanges including gaskets and bolts. 1 xø1 xø1 TM Counter flanges according to ISO Blanking flanges Fig. 3 Base plate for UPE Adapter flanges Pressure stage Size Product number MAGNA 3 PN 1 Rp 1 1/ mm 5397 MAGNA PN 1 Rp 1 1/ mm 5397 MAGNA 5 PN 1 Rp mm 59 MAGNA (D) 3-1 F MAGNA (D) -1 F MAGNA (D) 5- F MAGNA (D) 5-1 F MAGNA (D) 5- F MAGNA (D) 5-1 F UPED -1 F UPED 1- F Product number Rp: mm: Flange with internal thread (ISO seal thread). Flange for welding/soldering. 51

52 Accessories MAGNA, UPE Union and valve kits Union kits Pressure stage Size Product number Rp 3/ 5991 MAGNA/UPE 5 PN 1 Rp Rp 1 1/ 597 MAGNA/UPE 3 PN 1 Rp Rp 1 1/ 599 Valve kits Pressure stage Size Product number Rp 3/ 5195 MAGNA/UPE 5 PN 1 Rp Rp 1 1/ 5197 MAGNA/UPE 3 PN 1 Rp 1 1/ Insulating shells for aircondition applications Product number MAGNA 3-1 F 9515 MAGNA -1 F MAGNA 5- F 9515 MAGNA 5-1 F 9515 MAGNA 5- F MAGNA 5-1 F Insulating shells for UPE Product number UPE 15-, 5-, 3-, 5-, UPE 5- A, 5- A 55 UPE -1 F 935 UPE 1- F 93 Insulation kits MAGNA/UPE single-head pumps can be fitted with insulating shells. A kit consists of two shells. All MAGNA are all delivered with insulating shells for heating applications. Insulation shells are optional for UPE pumps. TM Fig. 1 Fitting the insulating shells to a MAGNA pump TM Fig. Fitting the insulating shells to a UPE pump 5

53 Accessories MAGNA, UPE Expansion modules for MAGNA 5-, 3-, 5-1, 3-1, -1(D), 5-1 MAGNA pumps can be fitted with an expansion module enabling communication via external signals (signal transmitters). Two types of expansion module are available: GENI module Relay module. Product Product number GENI module Relay module 9333 GENI module The GENI module offers the following functions: External start/stop The GENI module incorporates a digital input for an external contact. The pump can be started and stopped via this input. When started, the pump will operate with the setpoint set on the control panel or with the R1. External forced control The GENI module incorporates inputs for external signals for the forced-control functions: Max. curve duty Min. curve duty. External analog -1 V control The GENI module has an input for an external -1 VDC analog signal transmitter. Via this input, the pump can be controlled by an external controller if the pump has been set to one of the following control modes: Constant curve The external analog signal will control the pump curve within the range from the min. curve to the constant curve selected according to the characteristic. Proportional- or constant-pressure control The external analog signal will control the setpoint for the pump head between the setpoint corresponding to the min. curve and the setpoint selected according to the characteristic. Fault, ready and operating indication via signal relay The function of the signal relay can be set with the R1. Possible functions: Fault Ready Operation. Fault indication The signal relay is activated in case of Pump blocked Internal fault Undervoltage. Ready indication The signal relay is active when the pump is in operation or ready for operation. Operating indication The signal relay is active as long as the pump is operating. If the pump is stopped on the control panel, with the R1 or because of a fault, the signal relay is deactivated and consequently gives a signal to an external control system, e.g. a building management system. Control of twin-head pumps When fitted with two GENI modules, a twin-head pump functions fully automatically. A GENI module must be mounted on the control box of each pump head and the modules must be connected using a cable. Both pump heads must be connected to the electricity supply. Bus communication via GENIbus The GENI module enables serial communication via an RS-5 input. The communication is carried out according to the Grundfos bus protocol, GENIbus, and enables connection to the GRUNDFOS Pump Management System, a building management system or another type of external control system. Via the bus signal, it is possible to set pump operating parameters, such as desired setpoint, temperature influence, operating mode, etc. At the same time, the pump can provide status information about important parameters, such as actual head, actual flow, power input, fault indications, etc. Inputs for max. and min. curves and start/stop Input for analog -1 V signal Input for control of twinhead pumps Bus input Output for signal relay External potential-free contact. Contact load: 5 V, 1 ma. Screened cable. Loop resistance: Maximum 13 Ω. External signal: -1 VDC. Maximum load: 1 ma. Screened cable. Screened cable. Wire cross section:.5-1 mm. Cable length: Maximum 1 m. Grundfos GENIbus protocol, RS-5. Screened cable. Wire cross section:.5-1 mm. Cable length: Maximum 1 m. Potential-free changeover contact. VAC, A AC1. 3 VDC, A. 53

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

Series description: Wilo-Yonos MAXO

Series description: Wilo-Yonos MAXO 16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

Series description: Wilo-Yonos MAXO-D

Series description: Wilo-Yonos MAXO-D ATAC Solutions LTD / 1 / Series description: 1 /,5-1 1 5/,5-1 3/,5-7 3 3 5/ /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

Grundfos solar surface pump

Grundfos solar surface pump GRUNDFOS DATA BOOKLET Grundfos solar surface pump Renewable energy-based water supply systems Grundfos solar surface pump Table of contents 1. MGFlex motor 3 Features and benefits 3 Nameplate 3 Connection

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS

More information

Series description: Wilo-Star-Z

Series description: Wilo-Star-Z H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system

More information

LC/LCD ranges level controllers

LC/LCD ranges level controllers GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice

More information

Series description: Wilo-Drain TC 40

Series description: Wilo-Drain TC 40 Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site

More information

Catalogue Wilo- Stratos PARA

Catalogue Wilo- Stratos PARA Heating, ir Condition, Cooling, Geothermal heat, Solar heat 25-50W 100W 200W Catalogue Wilo- Stratos PR Wilo-Stratos PR 15/1-5; 20/1-5; 25/1-5; 30/1-5 Wilo-Stratos PR 15/1-7; 20/1-7; 25/1-7; 30/1-7 Wilo-Stratos

More information

Flygt 3068, 50Hz. Technical Specification

Flygt 3068, 50Hz. Technical Specification Flygt 3068, 50Hz Technical Specification Table of Contents Table of Contents B-pump...2 Product description...2 Motor rating and performance curves...4 C-pump...6 Product description...6 Motor rating

More information

GRUNDFOS DATA BOOKLET. SQFlex. Renewable-energy-based water supply systems. 50/60 Hz

GRUNDFOS DATA BOOKLET. SQFlex. Renewable-energy-based water supply systems. 50/60 Hz GRUNDFOS DATA BOOKLET SQFlex Renewable-energy-based water supply systems 50/60 Hz SQFlex Table of contents 1. Product data 3 Performance range 3 Applications 4 SQFlex system 4 Type keys 6 Pumped liquids

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

The conditions below apply to the curves shown on the following pages.

The conditions below apply to the curves shown on the following pages. GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves

More information

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz VM, VMC, VMN Vertical Multistage Centrifugal Pump, 60Hz Approvals CERTIFICATE IQNet and SQS hereby certify that the organisation Swiss Pump Company AG 3645 Thun-Gwatt Switzerland Whole Company Design,

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

HYDRUS ULTRASONIC METER

HYDRUS ULTRASONIC METER HYDRUS APPLICATION HYDRUS is a static water meter based on the ultrasonic technology. This technology enables accurate calculation of water consumption and eliminates measuring deviations caused by sand,

More information

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100 CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL

More information

CR, CRI, CRN, CRE, CRIE, CRNE

CR, CRI, CRN, CRE, CRIE, CRNE Lenntech info@lenntech.com www.lenntech.com GRUNDFOS DATA BOOKLET CR, CRI, CRN, CRE, CRIE, CRNE Vertical multistage centrifugal pumps 5 z CR, CRI, CRN, CRE, CRIE, CRNE Table of contents 1. Product data

More information

T U R B I N E G A S M E T E R

T U R B I N E G A S M E T E R TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR INLINE SD-PUMPS WITH IEC-STANDARD MOTOR AT_-1/ Hz DN1 3 r/min min H G 1/ G 1/ 17 11 3xM, Depth 1 1 Ø1 Ø1 xø19 7 3xØ1 9 17 1 xø1 17 1 kw A kg H OKN-13 E1 F19 7. (9). 9 OKN-13 C1 F19. (.) 11. 1 9 OKN-1 E1

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range Electromechanical controls Air control Water control On/off room thermostats range On/off room thermostats range Electronic controls Air control On/off V30 range On/off V30 range Water control Master/slave

More information

Viscotherm sensor electronic differential pressure transmitter electronic viscosity controller electric control valve power supply unit starter box

Viscotherm sensor electronic differential pressure transmitter electronic viscosity controller electric control valve power supply unit starter box Viscotherm P R O D U C T B U L L E T I N 772 Series V92 Model VC Electronic Component System Fig. 1, Viscotherm Viscotherm is a registered trade mark of VAF Instruments B.V. Introduction The benefits of

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

GRUNDFOS PRODUCT GUIDE. SQFlex. Renewable-energy based water supply systems 50/60 Hz

GRUNDFOS PRODUCT GUIDE. SQFlex. Renewable-energy based water supply systems 50/60 Hz GRUNDFOS PRODUCT GUIDE SQFlex Renewable-energy based water supply systems 0/60 Hz SQFlex Table of contents 1. Product data 3 Introduction 3 Applications Features and benefits Performance range 7 System

More information

Refrigeration Compressed Air Dryer Buran Ultrapulse

Refrigeration Compressed Air Dryer Buran Ultrapulse Refrigeration Compressed Air Dryer Buran Ultrapulse There is more to compressed air than just compressing air Compressed air is an indispensable source of operating and processing power in all areas of

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

Self-operated Temperature Regulators Temperature Regulator Type 1u

Self-operated Temperature Regulators Temperature Regulator Type 1u Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Data sheet ECC 12 and 22

Data sheet ECC 12 and 22 Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe

More information

MTR, MTRE, SPK, MTH, MTA

MTR, MTRE, SPK, MTH, MTA GRUNDFOS DATA BOOKLET MTR, MTRE, SPK, MTH, MTA Immersible pumps 5/6 Hz MTR, MTRE, SPK, MTH, MTA Table of contents 1. Introduction 3 2. Applications 4 3. Performance range 6 MTR, 5 Hz 6 MTRE, 5 Hz 6 MTR,

More information

1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm]

1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm] Product review: Range: Wilo-Star....... Star F Star Star Star F Star Star FX [m /h] Wilo-Star Cast iron body Hz [US gpm].......... [m /h] Wilo-Star Bronze body 9 Hz [US gpm] Star Star Star Star Star BF

More information

2.24. Pump Controller 704. Data Sheet

2.24. Pump Controller 704. Data Sheet Pump Controller 704 2.24 There are several reasons to choose an MJK pump controller. Pump controller 704, as described in this data sheet, was introduced in 1989. It has been updated several times with

More information

OZW30. Central Unit SYNERGYR

OZW30. Central Unit SYNERGYR 2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control

More information

2- and 3-port valves with flanged connections, PN 10

2- and 3-port valves with flanged connections, PN 10 4 402 VVF32.. VXF32.. ACVATIX 2 and 3port valves with flanged connections, PN 10 From the largestroke valve line VVF32.. VXF32.. Performance valves for medium temperatures from 10 150 C Valve body of grey

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06 SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS LV SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz

More information

ABB i-bus KNX Fan Coil Controller FC/S 1.1

ABB i-bus KNX Fan Coil Controller FC/S 1.1 Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

VLT Series 3500 Adjustable Frequency Drive Instruction Manual Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415 Operation Instructions KleeBlower Compressor/Vacuum pumps Models: KB129 KB8415 Brd. Klee A/S All rights reserved Edition 01/2012 Head office: Branch office: Brd. Klee A/S Klee Engineering Ltd Gadagervej

More information

LK Electric Boiler - 4,5

LK Electric Boiler - 4,5 LK Electric Boiler -, Design LK Electric Boiler, kw is a wall-mounted electric boiler, intended primarily for low-temperature heating systems, e.g. under floor heating. LK Electric Boiler, kw is delivered

More information

MEMBRANE VACUUM MINI PUMPS

MEMBRANE VACUUM MINI PUMPS MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free

More information

PS1800 Centrifugal Pumping Systems

PS1800 Centrifugal Pumping Systems PS1 Centrifugal Pumping Systems General Data and Sizing Tables The curve show the performance range of 4 models at 1Wp solar array - irradiation of 6kWh/m² on a tilted surface - ambient temperature 3 C

More information

Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1

Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1 Description NordicFlow s keep the system pressurized during normal conditions and prevent unnecessary activation of the main pump. They have compact design, high efficiency, low noise, reliable sealing

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

THE PERFECT FIT... GRUNDFOS UP PUMPS

THE PERFECT FIT... GRUNDFOS UP PUMPS TH PRFT FIT... GRUNFOS UP PUMPS Grundfos has the piece of the puzzle you need... When replacing a circulator pump, there is more to think about than simple mechanical dimensions. Like a jigsaw puzzle,

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

Installation and maintenance instructions. Danfoss Vent

Installation and maintenance instructions. Danfoss Vent Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4

More information

Type overview. Technical data

Type overview. Technical data Technical data sheet R3..xx-S.. Characterised control valve, 3-way, Internal thread For closed cold and warm water systems For modulating water-side control of air handling units and heating systems ir

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

Self-cooling, motor-independent frequency inverter. Performance data. Applications. Designation PumpDrivetypecode. Product description

Self-cooling, motor-independent frequency inverter. Performance data. Applications. Designation PumpDrivetypecode. Product description Type Series Booklet 4070.5/3--10 Self-cooling, motor-independent frequency inverter Mounting variants Motor mounting (MM) Wall mounting (WM) Cabinet mounting (CM) Applications Building services D Ventilation

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G EN 215-1 HD 1215-2 Application RA 2910 built-in sensor RA 2920 tamperproof RA 5062 remote sensor temperature adjuster RA-FN

More information

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for

More information

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?

More information

DSE5J 83 280/112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05)

DSE5J 83 280/112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05) 83 280/112 ED DSE5J DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05) p max 320 bar Q max 180 l/min MOUNTING SURFACE OPERATING

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The

More information

Condensing unit type EPSILON-ECHOS LE Technical information manual

Condensing unit type EPSILON-ECHOS LE Technical information manual Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps

More information

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet PI044E - Winding 311 Technical Data Sheet PI044E SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

Cool Design for Homes and Offices

Cool Design for Homes and Offices AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

PRODUCT PROFILE FEATURES

PRODUCT PROFILE FEATURES PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

PANASONIC TROUBLE SHOOTING GUIDE

PANASONIC TROUBLE SHOOTING GUIDE A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling

More information

Butterfly Valves PN 6/10/16 for flanged connection

Butterfly Valves PN 6/10/16 for flanged connection 4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information