Processing instructions Everest ZS-Blank. Always be on the safe side.

Size: px
Start display at page:

Download "Processing instructions Everest ZS-Blank. Always be on the safe side."

Transcription

1 Processing instructions Everest ZS-Blank Always be on the safe side.

2 Distributed by: KaVo Dental GmbH Bismarckring 39 D Biberach Tel Fax Manufacturer: Kaltenbach & Voigt GmbH Bismarckring 39 D Biberach

3 Table of contents Table of contents Table of contents 1 1 User instructions User guide Abbreviations Symbols Target group 2 2 Safety Description of safety instructions Warning symbol Structure Description of danger levels 3 3 Information on materials 4 4 Processing Preparing and planning the model Preparing the model Planning the model KaVo Everest ZS blanks Embedding ZS blanks Inserting the insert into the KaVo Everest engine Backfilling the ZS restoration Removing the ZS piece from the bed/sintering process KaVo Everest ZS round blank Insert the ZS circular blank into the KaVo Everest engine Round blank management Cutting the ZS restoration Sintering round blank restorations Final tasks Finishing the ZS piece Veneering ZS frameworks Incorporating the ZS piece 20 5 Identification plates 21 1/23

4 1 User instructions 1.1 User guide 1 User instructions 1.1 User guide Abbreviations Abbreviation GA PA REC TA STK IEC RA EMC VA Explanation Instructions for use Care instructions Assembly instructions Technician's instructions Safety checks International Electrotechnical Commission Repair instructions Electro magnetic compatibility Processing instructions Symbols See the section Safety/Warning Symbols Important information for users and technicians CE mark (Communauté Européenne). A product with this mark meets the requirements of the applicable EU directive. Action required Target group This document is for dental technicians and laboratory personnel. 2/23

5 2 Safety 2.1 Description of safety instructions 2 Safety 2.1 Description of safety instructions Warning symbol Warning symbol Structure DANGER The introduction describes the type and source of the danger. This section portrays the possible consequences of non-observance. The optional step covers necessary measures for avoiding hazards Description of danger levels Safety instructions with three hazard levels are used in this document for avoiding personal and property damage. CAUTION CAUTION indicates a hazardous situation that can cause damage to property, or mild or moderate physical harm. WARNING WARNING indicates a hazardous situation that can cause death or serious injury. DANGER DANGER indicates the maximum hazard level. indicates a directly hazardous situation that can cause death or serious injury. 3/23

6 3 Information on materials 3 Information on materials Zirconium dioxide as defined by materials science Zirconium dioxide is a high-performance, oxide ceramic. It is often called ceramic steel since it is extremely strong. The aesthetics of its translucence in thin walls are excellent, and it can also be stained in various colours. The biocompatibility of zirconium oxide is also excellent and has therefore been used for implants for years in addition to dentistry. In addition, its elasticity modulus is high, and resists breaking. This quality is achieved by doping with yittrium oxide. When external energy is applied, for example in a crack, the volume of the material increases at this site at room temperature in a stabile phase. The arising pressure counteracts the crack and prevents it from spreading and the ceramic from failing. The transformation is the basis of the high strength, the impressive toughness and excellent long-term stability. Zirconium oxide pieces made using CAD/CAM also have the following advantages: Corrosion resistance Very fine particle size No glass phase as the particle binder Extreme high density Porosity-free Conventional incorporation Adhesive or non-adhesive KaVo Everest ZS blanks and ZS round blanks consist of presintered, yittrium-stabilised zirconium oxide. They are easy to process in this soft state, and are fabricated larger in the KaVo Everest engine to compensate for the individually-calculated shrinkage factor, and then they are sintered to achieve full density in a special high-temperature oven, the Kavo Everest Therm. They shrink to form a very strong, precisely fitting framework. Technical data on the KaVo Everest ZS CTE (25 C to 500 C) 10.0 * 10 6 K -1 Flexural strength 1200 MPa Elasticity modulus 210 GPa Fracture toughness 8 MN/m 3/2 Chemical solubility 10 μg/cm 3 Thermal conductivity 2.5 W/ mk Material numbers for KaVo Everest ZS Mat. no , 16x16 (DxH), ZS(16) Mat. no , 20x20 (DxH), ZS(20) Mat. no , 42x20x16 (LxWxH), ZS(42/16) Mat. no , 42x20x20 (LxWxH), ZS(42/20) 4/23

7 3 Information on materials Mat. no , 60x25x20 (LxWxH), ZS(60/20) Mat. no , 100x16 (DxH), ZS(100x16) Mat. no , 100x20 (DxH), ZS(100x20) Mat. no , 100x25 (DxH), ZS(100x25) Indications for the KaVo Everest ZS Crown frameworks in the anterior and posterior areas Bridge frameworks in the anterior and posterior areas Primary conical crowns and telescopic crowns Inlay frameworks Implant abutments based on the Neolink for KaVo (Neoss) in the anterior and premolar regions Contraindications for the KaVo Everest ZS insufficient oral hygiene bruxism tangential preparations unsatisfactory preparation results post and cores unveneered crowns, inlays, onlays and bridges when there are more than two pontics when the bar cross-section is less than 12 mm 2 Implant abutments without Neolink (Neoss) Implant abutments in the molar region Cantilevered bridges Attachments It is the responsibility of the dentist to determine whether to use customized products such as long mandibular bridges. The crown and bridge frameworks made of Everest ZS blanks and ZS round blanks can be individually veneered with the veneer ceramic developed especially for zirconium dioxide. Preparation basics The preparation can be made either with a 90 hollow neck, or a shoulder with rounded inner edge. Try to achieve a circular preparation depth of 1 mm. All transitions from the axial to the occlusal or incisal surfaces are to be rounded off with a radius of 1 mm. Optionally, a radius correction can be made in the surface module of the construction software. See also: KaVo Everest preparation conditions Transportation and storage The ZS material is nonhazardous as defined by national and international regulations. 5/23

8 3 Information on materials Transportation/storage temperature -25 C to +80 C Humidity 5% to 95% Store KaVo Everest ZS blanks and ZS round round blanks in a clean and dry place at room temperature. Store the blanks in the original packaging at room temperature (20 C). Disposal Everest ZS blanks and ZS round blanks can be disposed with household garbage while observing local regulations (waste code: ). If permitted by regulations, the packaging can be recycled (used paper, cardboard) or disposed with household garbage. 6/23

9 4 Processing 4.1 Preparing and planning the model 4 Processing 4.1 Preparing and planning the model Preparing the model Apply the criteria of conventional casting when preparing the model and dies. Observe care in preparation to ensure a precise fit later. All model segments must be designed to be removable. They must easily release from the base to prevent a blur when later removing the individual stumps in the scanner. A conventional plaster base is recommended. Do not use white or reflective plates since they can negatively influence measurement. It is essential to use Everest Rock (100 g: 20 ml) to manufacture the dental arch. Other plasters can impair measurement. The preparation margin should be exposed at a 90 angle. Sharp angles can cause a loss of data at these sites. Do not mark the preparation margin. Waxing in and rounding sharp-edged preparations ensures an easier fit. This can be done with Everest Scan Wax or a light-hardening opaque plastic. The stumps may not be treated before scanning. Do not use stump varnish, die spacer or hardener. The model preparation method for working with the Neolink can be found in the instructions for use of the KaVo Everest Energy CAD software Planning the model For a safe construction, do not undershoot the following CAD parameters: Metal margin A = 0.3 Framework thickness B = 0.55 The minimum cross-section of the bars depends on the span of the bridge: 3-member: min. 9 mm 2 4-member: min. 12 mm 2 more than 4-member: min. 16 mm 2 To ensure safe work, the transitional area X = 0.5 may not be larger. The shape of the bars has a direct influence on the stability of the work. A round or oval cross-section provides better static reinforcement than a square one The height of the bar is more important than its width 7/23

10 4 Processing 4.2 KaVo Everest ZS blanks The shape 1 is not suitable for manufacturing with the round blank. 4.2 KaVo Everest ZS blanks Check the concentration, purity and level of the cooling lubricant weekly (see the instructions for use of the combination and base test). To ensure sufficient fixing, change the setscrews in the gripping yokes and tools every four months. Use the following ZS burrs for shaping: KaVo Everest Milling Pin ZS 3 (3 mm dia.) Mat. no KaVo Everest Milling Pin ZS 1 (1 mm dia.) Mat. no Embedding ZS blanks The ZS blanks should only be embedded when necessary. While embedding, the Everest label must be on top so that it can be read. Do not embed them in advance. Avoid covering the Everest label with Universal Inplast while embedding. For Universal Inplast, always mix components A and B at a precise weight ratio of 1:1. Shake container a well before use. The Universal Inplast components must be mixed very well for approximately seconds. 8/23

11 4 Processing 4.2 KaVo Everest ZS blanks The Universal Inplast must be mixed well. The homogeneity of the plastic can otherwise be uneven and the plastic may not cure evenly. This can cause the blank to loosen and may generate problems with milling. Choose a ZS positioning appliance appropriate for the blank size. Insulate the ZS positioning appliance well with Vaseline. Then place the insert on the positioning appliance, and also tighten the thumb screws. Make sure the insert is precisely seated. When using the silicone positioning tool: Use Vaseline to close the holes in bridge inserts. Do not use Vaseline to insulate the inside of the insert. With bridges, fill the insert with Universal Inplast up to the top edge of the blank. In the case of crown bridges, fill the insert with Universal Inplast up to the top edge of the insert. Once the Everest Universal Inplast is completely hardened, remove the positioning appliance from the insert. Do not forcefully break it out since this may damage the blank Inserting the insert into the KaVo Everest engine Affix the insert at the desired location on the yoke, and affix the setscrews in the front of the gripping yoke. Then select the provided job and assign it to the corresponding production site. The "Define blank" dialog opens. 9/23

12 4 Processing 4.2 KaVo Everest ZS blanks To determine the shrinkage factor and the LOT number, the ID Reader must be held on the middle of the label of the blank. The Everest Label must be removed before production. Fix the insert in the KaVo Everest gripping yoke at the provided place. Start the milling program. See also: Instructions for use for the KaVo Everest engine (Mat. no ) Instructions for use for the KaVo Everest engine Base Camp 4140 (Mat. no ) Backfilling the ZS restoration After grinding the cavity, the program automatically stops so that the inside can be filled. Do not remove the gripping yoke or insert from the engine. 10/23

13 4 Processing 4.2 KaVo Everest ZS blanks The cooling lubricant and grinding residue must be rinsed out well with water. Preferably use a spray bottle. Then gently dry the cavity with oil-free compressed air. Make sure that the compressed air does not enter the spindle. Heat the cavity well and evenly to about 45 C for at least one minute/unit at a distance of cm. A hairdryer works best. A hair drier with max. 1,600 Watt output is recommendable for gentle heating. Properly heating is essential for successful production. Do not use a hot hair drier for heating. 11/23

14 4 Processing 4.2 KaVo Everest ZS blanks CAUTION Hot, liquid wax Burns Be particularly cautious when working with hot, liquid wax. The Inwax should not be heated in the working area since it becomes excessively soiled and the Inwax cannot be heated in a controlled manner. or or It is best to heat the Everest Inwax in a fire-proof container (such as a new ceramic pickling bowl) to a max. 100 C. You can alternately use a chocolate heater (for example by Unhold). The ideal wax temperature is reached at level 2. The wax tends to separate, so it needs to be stirred well. Fill the preheated cavity. Pour in the wax up to the upper edge of the insert and overfill it just a bit. After the Inwax fully hardens, close the door of the Everest engine. Continue the program (see the screen). The Autostart function can alternatively be used. Select the time period after which the program is automatically continued. Set to at least 15 minutes for crowns and copings, and set to 20 to 40 minutes for bridges depending on the size. Abutments Items delivered with the "Neoss for KaVo" abutments: Designation Figure Description Abutment screw Material: Gold or titanium 1: Long thread 2: Chamfered screw tip Laboratory screw Material: Titanium 1: Short thread 2: Sharp-edged screw tip See also: Instructions concerning abutments by Neoss or Removing the ZS piece from the bed/sintering process After grinding, remove the insert with the finished casting from the gripping yoke. 12/23

15 4 Processing 4.2 KaVo Everest ZS blanks Use a hot wax knife to carefully and generously cut the casting from the insert, or place it in the preheating oven with the insert. Do not heat the casting with a hot air blower since it can cause heat cracks. CAUTION Hot preheating oven Burning hazard! Be particularly cautious when working with the preheating oven. To remove remaining wax, place the workpiece on a paper towel or muffle cloth in the preheating at a max. 100 C. Make sure that the oven is clean. Do not remove the casting from the preheating oven with a metal object (such as tweezers). Always avoid sudden temperature changes since they can generate cracks. Since zirconium oxide is very sensitive in the presintered state and cracks can form, do not work on it in this state. In addition, other materials such as from smoothing with a rubber wheel can be fired into the crown. For information on staining, consult the processing instructions of the respective manufacturer. Never dip the ZS piece into the stain when hot. The stained restoration must be thoroughly dry before starting the KaVo Everest therm. The radiation heat of the ceramic oven can be exploited. Cracks in the ZS material after sintering can arise from thermal stress and residual moisture before sintering. The sand must be completely sintered before it is used. 13/23

16 4 Processing 4.3 KaVo Everest ZS round blank To sinter the framework, place its occlusal side in the dish filled with sintering sand. Make sure that the framework parts are properly supported to prevent distortion during sintering. The framework should lie evenly and loosely in the sand. It may not be buried in the sand. The provided amount of sintering sand is enough for 3 units. The production should be protected from contamination up to sintering. Even minute metal particles in the sintering oven on the framework or in the sand can cause the zirconium to discolour green. ZS and HPC may not be sintered in the same sintering dish. Place the ceramic dish with the cut, de-waxed casting at room temperature in the KaVo Everest therm. Start the program. See also: Instructions for use for the KaVo Everest engine therm (Mat. no ). The electricity and compressed air supply must be ensured for night operation. 4.3 KaVo Everest ZS round blank Check the concentration, purity and level of the cooling lubricant weekly (see the instructions for use of the combination and base test). To ensure sufficient fixing, change the setscrews in the tools every four months (Mat. no ). Use the following ZS burrs to machine round blanks: KaVo Everest Milling Pin ZS 1 long (1 mm dia.) Mat. no KaVo Everest Milling Pin ZS 3 (3 mm dia.) Mat. no /23

17 4 Processing 4.3 KaVo Everest ZS round blank Insert the ZS circular blank into the KaVo Everest engine Place the round blank in the provided place on the KaVo Everest yoke. Use an appropriate clamping ring: ZS 100 x 16/25 or ZS 100 x 20. Place the clamping ring on the round blank. The groove in the round blank must be aligned with the pin in the yoke. Evenly tighten the hexagon socket screws. Make sure that the clamps lie on the edge of the clamping ring. Assign jobs. See also: Instructions for use for the KaVo Everest engine (Mat. no ) See also: Instructions for use for the KaVo Everest engine Base Camp 4140 (Mat. no ) After the fitting side is produced, the yoke automatically turns over and the occlusion starts to be milled. 15/23

18 4 Processing 4.3 KaVo Everest ZS round blank Round blank management Positioning the restorations Sufficient ZS material must be between the individual units so that the round blank remains stable and the restorations do not break out. Minor overlaps of the individual restorations may occur, but not of the bars. Define bars No bars may be deleted from any of the ZS pieces. The bars may be cut depending on the size of the piece. The bars must be positioned at a right angle to the framework. Coping Leave all 4 bars in an activated state (blue). Bridges 2 to 4 elements Leave 2 bars in an activated state (blue) on each of the terminal members. The remaining bars of pontics can be cut (green) or reduced (brown). The bars of stumps (teeth) may not be cut. Leave them in an activated state or reduce them. 16/23

19 4 Processing 4.3 KaVo Everest ZS round blank Bridges 5 to 6 elements: Leave 2 bars in an activated state (blue) on each of the terminal members and the middle members. The remaining bars of pontics can be cut (green) or reduced (brown). The bars of stumps (teeth) may not be cut. Leave them in an activated state or reduce them. Setting pins Pins can be generated to provide sufficient retention and prevent distortion when sintering large pieces on the sintering plate. No pins may be set on the copings. Pins may be created on bridges depending on their size and geometry. If pins are created, put a pin on each unit. The pins must be offset, i.e., not in a line, to ensure that they provide reliable retention. Pins may not be place on the outer margin of the geometry. 17/23

20 4 Processing 4.3 KaVo Everest ZS round blank Cutting the ZS restoration The restorations can be carefully cut from the round blank using a suitable carbide cutter. Pay special attention to the edges of the restorations. 2 to 4 element bridges: 2-4 member bridges should be completely cut out of the material before being sintered. 5 to 6 element bridges: To prevent delays, the bridges can be sintered with the remaining round blank material. Leave bars on the lingual side of terminal copings and cut the other bars. The distance from the cut bars to the remaining material should be 1 mm Sintering round blank restorations Before sintering, the Everest chip must be removed from the round blank. Sintering bridges without residual round blank material Follow the instructions and descriptions for the sintering process. See also: Removing the ZS piece from the bed/sintering process, Page 12 18/23

21 4 Processing 4.4 Final tasks Sintering bridges with residual round blank material Use a sintering plate Place the ZS bridge on the pins, and sinter using the ZS round blank program. Cutting out the sintered ZS pieces from residual round blank material CAUTION Irritating dust when cutting out the sintered ZS piece Irritation of the eyes and mucosa! Grinding dust must not be inhaled. A dust mask and protective glasses are required. Cut the ZS piece from the residual round blank material while cooling with water and with the help of a turbine. Do not apply pressure, and use new diamond coated tools. 4.4 Final tasks Finishing the ZS piece The entire framework does not have to be reworked as is the case with metal frameworks. CAUTION Hot preheating oven Burning hazard! Be particularly cautious when working with the preheating oven. CAUTION Chips and irritating dust from finishing the polymers Irritation of the eyes and mucosa! Polymers must be worked on with a local dust extraction system. Make sure the milling dust does not get in the eyes. Avoid contact with mucous membranes. Grinding dust must not be inhaled. A dust mask and protective glasses are required. Do not eat or drink while working. After sintering, the ceramic bowl can be removed from the oven at 300 C. Remove the piece from the bowl when it is warm to the touch. Do not cool with compressed air. This can cause cracks. Do not inhale the zirconium sand. If needed, the cavity can be blasted with aluminium oxide 50 μm. 19/23

22 4 Processing 4.4 Final tasks Observe the additional instructions of the manufacturer of the utilised fastening material. If you need to refine a sintered ZS piece, use water cooling and a turbine. Do not apply pressure, and use tools with new diamonds. Avoid sparks. Do not blast the surfaces to be veneered - it is not necessary. However, preheating before veneering as instructed by Vita is recommended to relieve stress in the material and degrease the surface. Vt. C Hold Minute Heat Minute Heat C/minute as low as possible ca. Hold VAC temperature Minute Minute (source: Vita firing table for Vita VM9) Veneering ZS frameworks ZS frameworks must be veneered. The surfaces to be veneered do not have to be blasted. The remaining veneer procedure can be found in the processing instructions of the respective veneer ceramic manufacturer Incorporating the ZS piece Provisional cementing is highly inadvisable. Before the framework is inserted in a patient s mouth, it needs to be sufficiently cleaned and disinfected. The framework is permanently inserted using the usual fastening materials for adhesive and non-adhesive fastening. Additional information can be obtained from the preparation guide. 20/23

23 5 Identification plates 5 Identification plates ZS blanks Material number Abbreviation of the dimension B 42/ B 42/ B 60/20 Type Everest ZS blank (X) Material, (dimension in mm) Quantity REF Reference number or material number CE mark according to EC Directive 93/42 for medical devices Batch ID Date of manufacture Year - month Reference to maximum use (Same as "Can be used until...") Year - month Observe processing instructions 21/23

24 5 Identification plates ZS circular blank Type Everest ZS round blank (X) Material, (dimension in mm) Quantity REF Reference number or material number CE mark according to EC Directive 93/42 for medical devices Batch ID Date of manufacture Year - month Reference to maximum use (Same as "Can be used until...") Year - month Observe processing instructions Material number Dimension dia. 100 x dia. 100 x dia. 100 x 25 Storage and transport 22/23

25 5 Identification plates Air pressure range 700 hpa to 1060 hpa Humidity range 5% to 95% Temperature range -25 C to +80 C Permissible stacking load 10 Kg Fragile - protect against impact. Protect from moisture. Protect from radiation and sunlight. 23/23

26

27

28 kb en

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES Straumann Anatomic IPS e.max Abutment The ITI (International Team for Implantology) is academic partner of Institut Straumann in the areas of research

More information

DESS. Screws. Tijuana Ventas: (664) 685 6294/95 [email protected]. For all major implant systems!! www.dabocorp.com

DESS. Screws. Tijuana Ventas: (664) 685 6294/95 hirambogarin@dabocorp.com. For all major implant systems!! www.dabocorp.com Screws Screws for definitive use. Made from medical grade 5 ELI Titanium Integrity and soundness guaranteed by stress tests of up to 150% of their nominal torques. Their designs ensure a perfect fit with

More information

IPS e.max CAD C16. Larger Size Block Low translucency Shades: A1, A2, A3, A3.5, B1, B2, C1, C2, D2, BL2 Indicated for single unit restorations

IPS e.max CAD C16. Larger Size Block Low translucency Shades: A1, A2, A3, A3.5, B1, B2, C1, C2, D2, BL2 Indicated for single unit restorations IPS e.max CAD C16 IPS e.max CAD C16 Larger Size Block Low translucency Shades: A1, A2, A3, A3.5, B1, B2, C1, C2, D2, BL2 Indicated for single unit restorations Full and partial coverage single units Large

More information

ZIRCONIA INFORMATION FOR DENTISTS. FAQ S from the dental practice ENGLISH

ZIRCONIA INFORMATION FOR DENTISTS. FAQ S from the dental practice ENGLISH ZIRCONIA INFORMATION FOR DENTISTS FAQ S from the dental practice ENGLISH Zr Facts and Answers 2 Facts and Answers What is Zirconia? Zirconium (ZrSiO ) belongs to the mineral group of silicates and 4 was

More information

priti crown Your patients deserve you

priti crown Your patients deserve you priti crown Your patients deserve you 3 and you deserve the priti crown So close to nature priti crown is a high-tech solution for making perfect crown and bridge restorations using state-of-the-art CAD/CAM

More information

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests Product Data Sheet Edition 05/12/2014 Identification no: 020204030010000044 Sikadur -41 CF Rapid 3-part thixotropic epoxy patching mortar Construction Product Description Uses Characteristics / Advantages

More information

Restorative Guidelines

Restorative Guidelines Restorative Guidelines Contents Restorative Guidelines 4.1 Neoss Implant System 4.2 4.2 Esthetiline Solution 4.3 4.3 Provisional Abutments 4.8 4.4 Impression Techniques Implant Level 4.12 4.5 NeoLink

More information

IPS. Special Edition. Press-on-Metal Ceramic. Harald Gritsch Max Wörishofer Christoph Zobler

IPS. Special Edition. Press-on-Metal Ceramic. Harald Gritsch Max Wörishofer Christoph Zobler InLine PoM Press-on-Metal Ceramic IPS Special Edition Harald Gritsch Max Wörishofer Christoph Zobler Press-on technique on metal frameworks Combining the widely known casting technique and press technique

More information

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT Straumann Variobase Abutment 1 The ITI (International Team for Implantology) is academic partner of Institut Straumann AG in the areas of research

More information

NetShape - MIM. Metal Injection Molding Design Guide. NetShape Technologies - MIM Phone: 440-248-5456 31005 Solon Road FAX: 440-248-5807

NetShape - MIM. Metal Injection Molding Design Guide. NetShape Technologies - MIM Phone: 440-248-5456 31005 Solon Road FAX: 440-248-5807 Metal Injection Molding Design Guide NetShape Technologies - MIM Phone: 440-248-5456 31005 Solon Road FAX: 440-248-5807 Solon, OH 44139 [email protected] 1 Frequently Asked Questions Page What

More information

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall

More information

Full Crown Module: Learner Level 1

Full Crown Module: Learner Level 1 Full Crown Module Restoration / Tooth # Full Gold Crown (FGC) / 30 Extensions: Porcelain Fused to Metal (PFM) / 12 All Ceramic / 8 Learner Level 1 Mastery of Tooth Preparation Estimated Set Up Time: 30

More information

New features DWOS 3.2

New features DWOS 3.2 New features DWOS 3.2 Version 1.1 Septembre 13 th 2012 Summary This document describes how to use the new features and improvements of the release 3.2.0 of the Dental Wings Open Software (DWOS). Order

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

Precise. Powerful. Pure.

Precise. Powerful. Pure. DATRON D1pure 2 Precise. Powerful. Pure. 3 DATRON Worldwide references p. 32 DATRON DentalCAM p.20 Scanners p.28 CAD p.28 4 Dental materials and Dental milling tools p. 24 DATRON D1 pure p. 7 We Understand

More information

How to build a Pizza Oven in 4 days

How to build a Pizza Oven in 4 days How to build a Pizza Oven in 4 days Preparation day (slab) 1. Foundation 1500 deep x 1300 wide x 75mm deep Required 20 bags cement pre mix. If you already have a concrete base, you save this prep day DAY

More information

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment Contents TS Implant System Cement retained restoration Screw retained restoration 06 Cement-retained bridges with the Solid abutment system (non- 72 Screw retained crown with the ComOcta Gold abutment

More information

all digital all options The right milling option High precision and productivity

all digital all options The right milling option High precision and productivity all digital all options The innovative FULL CONTOUR milling system ZIRCONIA The right milling option High precision and productivity Customized digital solutions for every laboratory Preparation Scanners

More information

Jacket crown. Advantage : Crown and Bridge

Jacket crown. Advantage : Crown and Bridge Crown and Bridge Lecture 1 Dr.Nibras AL-Kuraine Jacket crown It is a type of crown that is formed by a tooth colored material. It is mainly used as a single unit in the anterior quadrant of the mouth.

More information

COATED CARBIDE. TiN. Al 2 O 3

COATED CARBIDE. TiN. Al 2 O 3 COATED CARBIDE GENERAL INFORMATION CVD = Chemical Vapour Deposition coated grades GC2015, GC2025, GC2135, GC235, GC3005, GC3015, GC3020, GC3025, GC3115, GC4015, GC4025, GC4035, S05F, and CD1810. PVD =

More information

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast

More information

WSD130 SOLDERING STATION

WSD130 SOLDERING STATION NOTES S2032ACH 8/98 Rev. 11/01 WSD130 SOLDERING STATION 1. Power Switch 2. Digital Display 3. UP Button 4. DOWN Button 5. Optical Regulator, Right 6. Connection for Soldering Iron, Right 7. Selection Switch

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

Guidance for implant removal. Straumann Dental Implant System

Guidance for implant removal. Straumann Dental Implant System Guidance for implant removal Straumann Dental Implant System The ITI (International Team for Implantology) is academic partner of Institut Straumann AG in the areas of research and education. ContentS

More information

Pet hair clipper. Model 96822. Diagrams within this manual may not be drawn proportionally.

Pet hair clipper. Model 96822. Diagrams within this manual may not be drawn proportionally. Pet hair clipper Model 96822 Cleaning And Operation Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the

More information

Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment

Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment Whatever You Rebuild, Repair and Protect...... Find the Right Solution! Henkel's Solutions for all Surface Engineering Needs

More information

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment. Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment. Dr. med. dent. David McFadden, Dallas County, USA Initial situation (single X-ray) Tooth 16

More information

Troubleshooting. Crown and Bridge Technique

Troubleshooting. Crown and Bridge Technique Troubleshooting Crown and Bridge Technique Dear Customer, Thank you for selecting Dentaurum products for crown and bridge dental prostheses. You decided to purchase high quality products that are precisely

More information

A New Beginning with Dental Implants. A Guide to Understanding Your Treatment Options

A New Beginning with Dental Implants. A Guide to Understanding Your Treatment Options A New Beginning with Dental Implants A Guide to Understanding Your Treatment Options Why Should I Replace My Missing Teeth? Usually, when you lose a tooth, it is best for your oral health to have it replaced.

More information

Achat 208 HL / 208 HR passive mid-range speaker. user manual

Achat 208 HL / 208 HR passive mid-range speaker. user manual Achat 208 HL / 208 HR passive mid-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: [email protected] Internet:

More information

PRESS. Pressable Ceramic System. Perfect shades first time every time. Instruction Manual. Products for better dentistry

PRESS. Pressable Ceramic System. Perfect shades first time every time. Instruction Manual. Products for better dentistry Pressable Ceramic System PRESS Perfect shades first time every time Instruction Manual Products for better dentistry Pressable Ceramic Pressable Ceramic System PRESS Perfect shades first time every time

More information

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI Taking the Mystique out of Implant Dentistry Dr. Michael Weinberg B.Sc., DDS, FICOI What is Restorative Implant Dentistry? Restorative implant dentistry involves taking a few simple mechanical principles

More information

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout. Two-component flexible, waterproofing and protective cementitious grout. 1504-2 PI-MC-IR Technical features Two-component grout, based on cements, selected aggregates, special additives and synthetic polymers

More information

CEREC inlab the multifunctional CAD/CAM system for modern dental restorations.

CEREC inlab the multifunctional CAD/CAM system for modern dental restorations. CEREC inlab the multifunctional CAD/CAM system for modern dental restorations. CEREC inlab technology CEREC inlab progress coupled with experience: Sirona s leading-edge CAD/CAM system. Sirona: a leading

More information

DO NOT OPERATE LANCELOT OR SQUIRE WITHOUT FIRST ADJUSTING THE SAFETY GUARD. ( See Below)

DO NOT OPERATE LANCELOT OR SQUIRE WITHOUT FIRST ADJUSTING THE SAFETY GUARD. ( See Below) Assembly Instructions - Lancelot and Squire King Arthur s Tools (KAT) is pleased to present the first tandem mounted saw chain accessories whereby differing combinations of Lancelot and Squire may be paired

More information

Regular C/X Prosthetics. Prosthetics

Regular C/X Prosthetics. Prosthetics Regular C/X Prosthetics /X C/ Prosthetics ANKYLOS C/X Prosthetics For more than 20 years, the ANKYLOS system developed by Prof. Dr. G.-H. Nentwig and Dr. Dipl.-Ing. Walter Moser with its TissueCare Connection

More information

AUSTENITIC STAINLESS DAMASCENE STEEL

AUSTENITIC STAINLESS DAMASCENE STEEL AUSTENITIC STAINLESS DAMASCENE STEEL Damasteel s austenitic stainless Damascene Steel is a mix between types 304L and 316L stainless steels which are variations of the 18 percent chromium 8 percent nickel

More information

Ultrasonic cleaning technology and cleaning chemicals

Ultrasonic cleaning technology and cleaning chemicals Ultrasonics.Steam.Ultraclean. Medicine Dental Hygiene Ultrasonic cleaning technology and cleaning chemicals Developed for and matched to the requirements in the dental sector www.elma-ultrasonic.com Elmasonic

More information

804 Ti Stand. Manual 8.804.8001EN

804 Ti Stand. Manual 8.804.8001EN 804 Ti Stand Manual 8.804.8001EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com 804 Ti Stand Manual 8.804.8001EN 06.2010 ek Teachware

More information

Complete Denture Processing Luther A. Ison, CDT

Complete Denture Processing Luther A. Ison, CDT Complete Denture Processing Luther A. Ison, CDT Festooning and preparation for processing Flasking Boilout procedures Packing acrylic Recover and divesting Cut wax at an obtuse angle leaving

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Digital impression solutions. 3M True Definition Scanner. Precise. impressions. in a jiffy

Digital impression solutions. 3M True Definition Scanner. Precise. impressions. in a jiffy Digital impression solutions 3M True Definition Scanner Precise impressions in a jiffy True Definition Scanner Digital impressioning redefined Easy handling. Desired result. With the 3M True Definition

More information

Implants of high-performance ceramic. vk-lange 12.03.2007 14:44 Uhr Seite 1. One-piece precision implant. Made in Germany

Implants of high-performance ceramic. vk-lange 12.03.2007 14:44 Uhr Seite 1. One-piece precision implant. Made in Germany OMNIS Implants of high-performance ceramic vk-lange 12.03.2007 14:44 Uhr Seite 1 One-piece precision implant C M Y CM MY CY CMY K Dieter Lange Verkaufsleiter Labor Made in Germany creamed nge 12.03.2007

More information

PET-10 INSTRUCTION MANUAL PRESSURE TANK

PET-10 INSTRUCTION MANUAL PRESSURE TANK INSTRUCTION MANUAL PRESSURE TANK PET-10 This manual contains IMPORTANT WARNINGS and INSTRUCTIONS. Equipment in this manual is exclusively for painting purposes. Do not use for other purposes. The operator

More information

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts: Two most common lock nut groups: 1. PREVAILING TORQUE a design feature of the lock nut produces friction between threads of mated components thereby increasing the force needed to tighten as well as loosen

More information

Achat 110 M passive full-range speaker. user manual

Achat 110 M passive full-range speaker. user manual Achat 110 M passive full-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: [email protected] Internet: www.thomann.de

More information

Choosing the right type of abutment

Choosing the right type of abutment 50 Producing custom implant abutments using CAD/CAM Choosing the right type of abutment S. KHALILOVA 1, F. KISTLER 2, S. ADLER 3, S. WEISS 3, S. KISTLER 2 AND J. NEUGEBAUER 2,4 Rapid developments in the

More information

Chapter 2 Basis of design and materials

Chapter 2 Basis of design and materials Chapter 2 Basis of design and materials 2.1 Structural action It is necessary to start a design by deciding on the type and layout of structure to be used. Tentative sizes must be allocated to each structural

More information

Summary. DWOS 3.8.0 New features. Version 1.2. May 08, 2014. Summary 1. Latest Additions 3. Orthodontic Archiving 3

Summary. DWOS 3.8.0 New features. Version 1.2. May 08, 2014. Summary 1. Latest Additions 3. Orthodontic Archiving 3 DWOS 3.8.0 New features Version 1.2 May 08, 2014 Summary The present document contains step- by-step instructions and images to guide the users through the major new features and improvements of the release

More information

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions Trillium 40 Axis Spring Tensioner Wire Replacement Instructions 1 Overview The objective is to replace the broken axis spring tensioner wire. This requires the following tasks: 1. Remove the seismometer

More information

Operator Quick Guide EC SENSOR

Operator Quick Guide EC SENSOR Operator Quick Guide EC SENSOR Revision G - 24/04/2008 General Information About This Guide The information in this guide has been carefully checked and is believed to be accurate. However, Hach Ultra

More information

FABRICATING CUSTOM ABUTMENTS

FABRICATING CUSTOM ABUTMENTS FABRICATING CUSTOM ABUTMENTS LUC AND PATRICK RUTTEN How much should a Dental Technician know about the clinical aspects of implantology? The answer is clear: as much as possible. This is the distinction

More information

Speed-Mat Rectangle Cutter

Speed-Mat Rectangle Cutter Speed-Mat Rectangle Cutter 1 Honeycomb baseboard. 2 Left hold down. 14 3 Bottom hold down. 4 4 Left / right rule. 8 5 8 5 Left / right rule pointer. 1 6 Top / bottom rule. 7 Top / bottom rule pointer.

More information

Saw Tooth Design and Tipping Materials

Saw Tooth Design and Tipping Materials Saw Tooth Design and Tipping Materials Bruce Lehmann, P.Eng, Ph.D. Sr. Engineer, Thin Kerf Technologies Inc. British Columbia, Canada Introduction The purposes of a saw tooth are to: 1. Remove a chip from

More information

SCREEN PRINTING INSTRUCTIONS

SCREEN PRINTING INSTRUCTIONS SCREEN PRINTING INSTRUCTIONS For Photo-Imageable Solder Masks and Idents Type 5600 Two Part Solder Masks and Idents Mega Electronics Ltd., Mega House, Grip Industrial Estate, Linton, Cambridge, ENGLAND

More information

Procedures & Products. NobelEsthetics

Procedures & Products. NobelEsthetics Procedures & Products NobelEsthetics First from Nobel Biocare. NobelPerfect, (NP, RP, WP), NobelDirect (NP, RP, WP), Brånemark System, NobelReplace and NobelSpeedy Implants. A complete assortment with

More information

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth. CHAPTER 10 RESTS AND DEFINITIONS A REST is any rigid part of an RPD framework which contacts a properly prepared surface of a tooth. A REST PREPARATION or REST SEAT is any portion of a tooth or restoration

More information

Structur. Structur 2 SC / Structur Premium EXCELLENT TEMPORARIES WITH STRUCTUR

Structur. Structur 2 SC / Structur Premium EXCELLENT TEMPORARIES WITH STRUCTUR Structur Structur 2 SC / Structur Premium EXCELLENT TEMPORARIES WITH STRUCTUR Simple to use Reliable products are required to provide your patients with prosthetic treatments, especially with regard to

More information

SMD Rework Station TABLE OF CONTENTS

SMD Rework Station TABLE OF CONTENTS SMD Rework Station Thank you for purchasing the Hakko 50B SMD Rework Station. The Hakko 50B is designed to solder and desolder surface mounted devices with hot air. Please read this manual before operating

More information

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time How to apply Arctic Alumina Premium Ceramic Thermal Adhesive 1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure

More information

Lathe Milling Attachment

Lathe Milling Attachment Lathe Milling Attachment By L C. MASON BY CLEVERLY stacking cold-rolled flat stock together, T-slots and slide for this lathe milling attachment are made without costly machinery. In fact, only two tools,

More information

IPS Empress CAD for CAD/CAM technology Information for Dentists. Confidence. Reliability. Esthetics. Empress CAD. The world s leading all-ceramic

IPS Empress CAD for CAD/CAM technology Information for Dentists. Confidence. Reliability. Esthetics. Empress CAD. The world s leading all-ceramic CAD for CAD/CAM technology Information for Dentists Confidence Reliability Esthetics The world s leading all-ceramic A time-tested system with new possibilities More versatility with revolutionized the

More information

Waxing up. Waxing up. Crown and bridgework. Friedrich Jetter Christian Pilz. Ideas for dental technology

Waxing up. Waxing up. Crown and bridgework. Friedrich Jetter Christian Pilz. Ideas for dental technology Waxing up Waxing up Crown and bridgework Friedrich Jetter Christian Pilz Ideas for dental technology Waxing-up units Waxing-up units Waxlectric II The Waxlectric II is an electrically regulated sculpting

More information

AISI O1 Cold work tool steel

AISI O1 Cold work tool steel T OOL STEEL FACTS AISI O1 Cold work tool steel Great Tooling Starts Here! This information is based on our present state of knowledge and is intended to provide general notes on our products and their

More information

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment by Dr. Ronald Jung and Master Dental Technician Xavier Zahno Initial situation

More information

Peasouper Operator s Manual

Peasouper Operator s Manual Peasouper Operator s Manual Contact Information Le Maitre Special Effects, Inc. Canada 1960 Blue Heron Drive, London, ON. N6H 5L9 Phone Direct: (519) 659.7972 Phone Toll Free Direct: (800) 388.0617 Fax:

More information

Treatment planning for the class 0, 1A, 1B dental arches

Treatment planning for the class 0, 1A, 1B dental arches Treatment planning for the class 0, 1A, 1B dental arches Dr.. Peter Hermann Dr Reminder: Torquing movement on tooth supported denture : no movement Class 1 movement in one direction (depression) Class

More information

HAIR CLIPPER. Model No. HC5150 HC5150 2. 3.

HAIR CLIPPER. Model No. HC5150 HC5150 2. 3. All technical modifications reserved. 09/08. TSC 08.0634 HAIR CLIPPER 2. 3. 1. Model No. HC5150 4. 10/UK/HC5150 Version 03/10 Part No. T22-29458 REMINGTON is a Registered Trade Mark of Spectrum Brands,

More information

Lapping and Polishing Basics

Lapping and Polishing Basics Lapping and Polishing Basics Applications Laboratory Report 54 Lapping and Polishing 1.0: Introduction Lapping and polishing is a process by which material is precisely removed from a workpiece (or specimen)

More information

Class I and II Indirect Tooth-Colored Restorations

Class I and II Indirect Tooth-Colored Restorations Class I and II Indirect Tooth-Colored Restorations Most indirect restorations are made on a replica of the prepared tooth in a dental laboratory by a trained technician. Tooth-colored indirect systems

More information

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com. Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without

More information

Universal Crown and Bridge Preparation

Universal Crown and Bridge Preparation Universal Crown and Bridge Preparation The All-Ceramic Crown Preparation Technique for Predictable Success According to Dr. Ronald E. Goldstein Expect the Best. Buy Direct. The Universal * Crown and Bridge

More information

CONTROLLING CROSS INFECTION IN THE DENTAL LABORATORY. Best Practice Guide

CONTROLLING CROSS INFECTION IN THE DENTAL LABORATORY. Best Practice Guide CONTROLLING CROSS INFECTION IN THE DENTAL LABORATORY Best Practice Guide Preparing to Work A separate work area shall be set aside in the laboratory to receive all incoming work. This should ideally be

More information

EP2242393; WO2012/080751; GB1210274.5

EP2242393; WO2012/080751; GB1210274.5 Curl Secret 2667U UK Patent and Application Nos. GB2455716; EP2242393; WO2012/080751; GB1210274.5 BaByliss CURL Secret The BaByliss Curl Secret has revolutionary technology to effortlessly create beautiful,

More information

Cementation and Sterilization Guidelines for Labs and Dentists. Lava. Zirconia for Implant Abutments. Cementation and Sterilization.

Cementation and Sterilization Guidelines for Labs and Dentists. Lava. Zirconia for Implant Abutments. Cementation and Sterilization. Cementation and Sterilization Guidelines for Labs and Dentists Lava Zirconia for Implant Abutments Cementation and Sterilization Made Easy Zirconia for Implant Abutments Use your 3M ESPE Lava Scan ST Design

More information

Gear PEPSI CAN STOVE INSTRUCTIONS

Gear PEPSI CAN STOVE INSTRUCTIONS Gear PEPSI CAN STOVE INSTRUCTIONS [NOTE: Updated Instructions are now available. The new stove is less likely to develop flame leaks and the fuel/air mixture is improved. Instructions for a simmer ring

More information

Classification of dental cements

Classification of dental cements Classification of dental cements Type I: Luting agents* that include temporary cements Class 1: powder-liquid -> harden Class 2: paste-paste -> remain soft Type II: Luting agents for permanent applications

More information

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major

More information

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS Straumann is the industrial partner of the ITI (International Team for Implantology) in the areas of research, development, and education. CONTENTS Product

More information

Base Cabinet with Self-storing Folding Doors and Floor

Base Cabinet with Self-storing Folding Doors and Floor Usable Kitchens When designing a kitchen for use by persons with mobility impairments, especially those who use wheelchairs, careful layout of the kitchen is crucial to maintaining accessibility. People

More information

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

The LOCATOR concept. Simplicity and versatility for prosthesis fixation The concept Simplicity and versatility for prosthesis fixation The concept Experience the freedom in prosthesis fixation Simple and secure fixation of implant-supported prostheses is essential for successful

More information

TECHNICAL DATA SHEET GRILON BG-15 S

TECHNICAL DATA SHEET GRILON BG-15 S TECHNICAL DATA SHEET GRILON BG-1 S Grilon BG-1 S is a heat stabilised PA6 injection moulding grade with 1% glass fibres. Grilon BG-1 S has the following important properties: Excellent surface finish Easy

More information

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised Page 1 of 6 instructions VC 104+ Rigid Grade / VC 104+ Rigid Grade Imagine / (for the rest of this document referred to as VC 104) can be applied to new and used trucks and trailers with painted rigid

More information

PROSTHETICS. Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM

PROSTHETICS. Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM PROSTHETICS Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM IMPORTANT NOTES Disclaimer of liability The ITI dental implant is part of an overall concept and may only

More information

Metal Injection Molding (MIM) of components made of Titanium and its alloys

Metal Injection Molding (MIM) of components made of Titanium and its alloys Metal Injection Molding (MIM) of components made of Titanium and its alloys 1 Presentation content Introduction to Metal Injection Molding (MIM) Technology - explaination Products - examples Company brief

More information

It s the Fuel For Your Success

It s the Fuel For Your Success It s the Fuel For Your Success Engineered For Success Today s patients demand aesthetic restorative outcomes that match or enhances their natural dentition. While this has traditionally been accomplished

More information

WAX-UP AND CERAMIC EXTENSIVE COURSE Dr. Dario Adolfi Dr. Ivan Ronald Huanca

WAX-UP AND CERAMIC EXTENSIVE COURSE Dr. Dario Adolfi Dr. Ivan Ronald Huanca WAX-UP AND CERAMIC EXTENSIVE COURSE Dr. Dario Adolfi Dr. Ivan Ronald Huanca Duration: 6 meses STEP 1: WAX-UP OF FOUR UPPER POSTERIOR TEETH with Dr. Ivan Ronald Huanca The objective of this course s step

More information

Product Innovations 2014/2. A Company of the SWAROVSKI Group www.tyrolit.com

Product Innovations 2014/2. A Company of the SWAROVSKI Group www.tyrolit.com Product Innovations 2014/2 A Company of the SWAROVSKI Group www.tyrolit.com Contents 2 Contents PREMIUM Cerabond System 4 PREMIUM Longlife für Steel 6 premium Deep Cut Protection 7 From a good idea to

More information

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER P110 Your battery charger has been engineered and manufactured to Ryobi s high standard for dependability, ease of operation, and operator safety. When properly

More information

VeMet, Utrecht, NL «Solution in Wear Protection» 26.10.2011 Dipl.-Ing. Wolfgang Leichnitz. Quit

VeMet, Utrecht, NL «Solution in Wear Protection» 26.10.2011 Dipl.-Ing. Wolfgang Leichnitz. Quit VeMet, Utrecht, NL «Solution in Wear Protection» 26.10.2011 Dipl.-Ing. Wolfgang Leichnitz Quit Theory and Practice of Wear Definition In materials science, wear is the erosion of material from a solid

More information

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725 Read this manual thoroughly before using and save it for future reference Purchase MAP capsules at Harvey Norman stores nationwide

More information

Araldite AV 170. Advanced Materials. One component epoxy adhesive. Structural Adhesives. Key properties. Description. Product data.

Araldite AV 170. Advanced Materials. One component epoxy adhesive. Structural Adhesives. Key properties. Description. Product data. Advanced Materials Araldite AV 170 Structural Adhesives Araldite AV 170 One component epoxy adhesive Key properties Cures at 140-180 C Heat resistant to 120 C Very good peel strength Good chemical resistance

More information

CELO5. User & Installation Manual. www.audac.eu

CELO5. User & Installation Manual. www.audac.eu CELO5 User & Installation Manual www.audac.eu 2 Introduction 5 High-end Slim Ceiling Speaker The CELO5 is the 5 version of AUDAC s CELO High-end Slim ceiling speaker series with an RMS power of 50 Watt

More information

Sinterstation. Pro Direct Metal SLM System

Sinterstation. Pro Direct Metal SLM System Sinterstation Pro Direct Metal SLM System Jim Dier SLS and SLM Systems, Upper Midwest 3D Systems, Inc. 18 July 2008 Introduction Product overview Systems Sinterstation Pro DM100 SLM System Sinterstation

More information

Round Housing with Side Ports

Round Housing with Side Ports Power Steering Steering Control Unit (SCU) Parts and Repair Information 5 Series Steering Control Units 001 Square Housing with Side Ports Round Housing with Side Ports T E L RP Round Housing with End

More information

150W. Bench Grinder. Article number BGM6018. WEB: helpdesk@d u o n s.c o m.a u. After Sales Support TEL: 07 3188 2025 N26968

150W. Bench Grinder. Article number BGM6018. WEB: helpdesk@d u o n s.c o m.a u. After Sales Support TEL: 07 3188 2025 N26968 150W Bench Grinder INSTRUCTION MANUAL MODEL NUMBER tbg-150 Article number BGM6018 AFTER SALES SUPPORT TEL: 07 3188 2025 WEB: [email protected] After Sales Support TEL: 07 3188 2025 N26968 WEB: helpdesk@d

More information

ALL-CERAMIC DENTAL IMPLANT SOLUTIONS

ALL-CERAMIC DENTAL IMPLANT SOLUTIONS ALL-CERAMIC DENTAL IMPLANT SOLUTIONS Scientific Evidence Bone-to-implant contact of 78% at 3 months. One piece implant = no prosthetic connections References 1. One-year follow-up of first consecutive

More information

15GAL STEEL OIL DRAIN WITH 110V PUMP

15GAL STEEL OIL DRAIN WITH 110V PUMP 15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information