QUALANOD SPECIFICATIONS UPDATE SHEET Nº 9 Edition page 1/5 COLD SEALING PROCESS
|
|
|
- Lindsay Bradford
- 10 years ago
- Views:
Transcription
1 page 1/5 COLD SEALING PROCESS Proposal QUALITAL QUALANOD resolution: Meeting in June 2010, October 2011 Date of application: 1 January 2012 Parts of the Specifications concerned: Section furthermore 2.3, 2.3.3, 3.3.1, 3.3.4, and Appendix I Terminology (for information) Modified paragraph: COLD SEALING PROCESS based on nickel salts and fluorinated salts (see following pages)
2 page 2/ Cold sealing process based on nickel salts and fluorinated salts This section gives prescriptions for the implementation of "cold sealing" processes based on nickel salts and fluorinated salts (notes 1, 2 and 3). It incorporates the knowledge about these processes gained in the past years, and defines the most important parameters. The process is divided into 2 steps: in the first one the anodic coating is sealed, in the second one the anodic coating is hydrated. Anodizing conditions As for other sealing processes it is essential to produce a good quality anodic oxide film according to the conditions stipulated in section Note 1 Cold sealing processes are based on chemicals which diffuse into the pores of the anodic oxide film and initiate a chemical reaction. It depends not only on the temperature but also on the chemicals used and other process factors. This specification relates only to cold sealing processes based on nickel fluoride. Note 2 The product available on the market can be a mixture of nickel salts and fluorides or fluorinated salts, where nickel fluoride can be only a minor part of the total amount. Note 3 Since the consumption of fluoride is slightly higher than the stoichiometric amount of nickel, some products on the market contain a slight excess of fluorides. A) First step of the sealing process 1) Concentration of the product: Nickel ion content 1.5 ± 0.3 g/l Free fluoride ions 0.50 ± 0.25 g/l 2) Bath temperature: 25 to 30 C 3) ph: (preferably 6.5 ± 0.2) 4) Sealing time: 1.0 ± 0.2 min/µm of the anodic coating 5) Phosphate ions in the solution shall be less than 5 ppm Rinsing after cold sealing is essential and it is strongly recommended not to use demineralised water. Note 4 An excess of fluorides, especially in presence of a low ph produces a rapid degradation of the solution due to a chemical attack to the oxide surface. This attack is evident especially on polished or brightened parts. Note 5 An excess of ions different from nickel and fluoride can induce a reduction in the activity of the solution; in this case filtration can help to overcome the problem.
3 page 3/5 SUPPLEMENTARY REQUIREMENTS Chemical components The supplier should give the anodiser precise details of the percentage of active components and, if a powder, the percentage of insoluble matter in the products. Preparation of the bath The quality of the water shall be checked before use; it is advisable to use demineralised water to make up the bath. Operating parameters The operating parameters for cold sealing are critically important and shall be closely controlled to achieve a satisfactory result. It is also important to remember that the parameters are interdependent; for example, a high fluoride ion concentration requires a lower operating temperature and/or a shorter sealing time and a higher ph. Bath concentration The most important bath constituents are nickel and fluoride. An excess of free fluoride ions can damage the anodic coating. The nickel ion and free fluoride contents shall be maintained within the following levels: Nickel ion content 1.5 ± 0.3 g/l free fluoride ion content 0.50 ± 0.25 g/l In some cases, 5-10% of the nickel may be substituted by cobalt to minimize the greenish shade. The free fluoride and nickel content of the bath shall be checked at least once per shift and the bath replenished with extreme care, avoiding use of the bath until the substances added have been fully solubilised. Sometimes, nickel fluoride can contain insoluble matter. It is advisable to make additions in a mixing chamber outside the bath. Moreover, fluoride is consumed at a higher rate than nickel, and additions of ammonium or potassium fluoride will be required to maintain the correct balance. Analytical methods for checking the baths should be provided by the supplier. Generally an EDTA method is used for nickel and a potentiometric method with an ion-sensitive electrode for free fluoride. Note 6 It is advisable to avoid the use of hydrofluoric acid or too acidic fluorinated salts able to unbalance the ph of the solution. Strong variations of ph are never positive for the final quality. Bath temperature The bath shall be maintained at a temperature between 25 C and 30 C with a sensitive thermostatic device. This parameter has a great influence on the kinetics of the process. Too high a temperature, particularly when the free fluoride concentration is at a high level, causes damage to the anodic oxide film and results in a powdery surface.
4 page 4/5 Bath ph The ph of the solution shall be maintained between (preferably 6.5 ± 0.2). Generally, the higher the ph the better, but it is not possible to go above 7.0 without causing a slight precipitation of nickel hydroxide. The ph affects the amount of nickel precipitated in the pores, and below 5.8 insufficient nickel is deposited, and a chemical attack on the anodic coating can be generated by fluoride. Note 7 The ph should be measured with utmost care as fluoride in the solution can attack the ph electrodes or damage the glass membrane. This makes it very important to check the ph electrodes at regular intervals. Sealing time The sealing time shall be 1.0 ± 0.2 min/µm of the anodic coating. Rinsing after cold sealing Thorough rinsing in cold tap water is essential after cold sealing. In fact demineralised water does not rinse properly and can contaminate the subsequent solution. B) Second step of the sealing process To complete the cold sealing process, the treated parts need to be exposed to high humidity for some time, which can be accelerated by dipping the cold sealed parts in a hot water bath. The bath shall contain either tap water and 4.0 ± 1.0 g/l nickel sulphate or nickel acetate, or demineralised water with an antismut additive, and shall be operated at a temperature of at least 60 C (preferably 70 C). The parts shall be immersed in the bath for 1.0 ± 0.2 min/µm. This treatment makes the work easier to handle and check, and shall be considered an essential part of the treatment. Thorough rinsing between cold sealing and the hot water treatment is absolutely essential as the fluoride ions can inhibit the conventional sealing processes. Cold sealed films are more prone to crazing than conventionally sealed films, especially when exposed in warm, dry environments. This effect is greatly reduced by the treatment in hot water after cold sealing. QUALITY CONTROL If the cold sealing process is applied as described, including immersion in hot water after cold sealing, the sealed work can be tested in the same way as conventionally sealed work. The most suitable tests are the dye spot test according to EN and the weight loss test according to EN The acceptance limits are those specified in sections and
5 page 5/5 2.3 Sealing and impregnation tests This section specifies the tests that shall be used to assess sealing quality and the associated criteria for acceptable performance. In cases where additives designed to prevent smutting are used in the sealing baths, special care should be exercised and greater attention paid to the referee test and the weight loss results and, where appropriate, the dye spot test Measurement of loss of mass after immersion in phosphoric acid/chromic acid solution with prior acid treatment according to EN (weight loss test) This test is the referee test to evaluate sealing quality. The maximum permissible loss of mass shall be 30.0 mg/dm². When a lot is to be inspected, the weight loss test shall always be performed on the part with the highest admittance or, if cold sealing impregnation is used, on the part with the highest thickness value Process requirements Sealing processes applying any principle other than hydrothermal sealing or cold sealing impregnation shall not be used unless they have been tested as stipulated in Appendix VI and approved by QUALANOD Anodizing This section indicates typical batch anodizing conditions with hydrothermal sealing or impregnation (cold sealing). Other electrolytes and/or other conditions may be used provided that the anodizing quality is at least as good as the quality produced by anodizing according to the Specifications Instruments and solutions for sealing tests The plant shall have at least one instrument for measuring admittance and a reference unit for checking the reading accuracy of the device. Exception: If a plant uses cold sealing impregnation only, this instrument is not necessary. App. I IMPREGNATION OR SO CALLED COLD SEALING OF ANODIZED ALUMINIUM A sealing treatment after anodizing consisting of impregnation based on nickel fluoride followed by ageing in a hot water treatment.
Specifications for the QUALANOD Quality Label for Sulphuric Acid-Based Anodizing of Aluminium
Specifications for the QUALANOD Quality Label for Sulphuric Acid-Based Anodizing of Aluminium Edition 01.07.2010 EFFECTIVE FROM 1 July 2010 This edition supersedes the previous edition (15.09.2004) and
Nickel Free Room Temperature Seal: an innovative and ecological process
Nickel Free Room Temperature Seal: an innovative and ecological process 2015 ANODIZING CONFERENCE San Diego, California Prepared by: Marcello Rossi Italtecno Srl Italy NICKEL FREE ROOM TEMPERATURE SEAL:
Anodizing Reference Guide
Anodizing Reference Guide Type Thickness Type II Conventional coatings produced 1.8µ-25.4µ from sulfuric acid bath Type I A Conventional coatings produced 0.5µ-7.6µ (microns) from chromic acid bath Type
Profiles for floors of same height Cerfix Projoint
PROFILPAS S.P.A. VIA EINSTEIN, 38 35010 CADONEGHE (PADOVA) ITALY TEL. +39 (0)49 8878411 +39 (0)49 8878412 FAX. +39 (0)49-706692 EMAIL: [email protected] s for floors of same height Cerfix Projoint Application
Iron and Manganese BACTERIA AND IRON AND MANGANESE
Iron and Manganese Iron and manganese control is the most common type of municipal water treatment in Minnesota. Iron and manganese occur naturally in groundwater. Neither element causes adverse heath
An Ammonium-free, Acid. Zinc/Nickel (12-15% Ni) Process
An Ammonium-free, Acid Zinc/Nickel (12-15% Ni) Process Requirements of an acid zinc/nickel process Technical requirements High plating speed (current efficiency up to 90 %) High thicknesses of deposits
Metal Rescue Rust Remover Technical Data
Technical Data Product Description Metal Rescue TM is an innovative new technology that efficiently removes rust without harming surrounding materials. It is a water-based, non-toxic solution that is biodegradable
A SHORT INTRODUCTION TO CORROSION AND ITS CONTROL
A SHORT INTRODUCTION TO CORROSION AND ITS CONTROL CORROSION OF METALS AND ITS PREVENTION WHAT IS CORROSION Corrosion is the deterioration of materials by chemical interaction with their environment. The
Metal Ion + EDTA Metal EDTA Complex
Simplified Removal of Chelated Metals Sultan I. Amer, AQUACHEM INC. Metal Finishing, April 2004, Vol. 102 No. 4 Chelating agents are used in large quantities in industrial applications involving dissolved
NIKAL BP RTU ELECTROLYTIC NICKEL SOLUTION For Advanced Packaging Applications
NIKAL BP RTU ELECTROLYTIC NICKEL SOLUTION For Advanced Packaging Applications Regional Product Availability N.America Japan/Korea Asia Europe Bath Make-up Component Nikal BP RTU Solution Percent by Volume
5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS
5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS Sl. No. Contents Preamble 5.1 Aim 5.2 Introduction 5.2.1 Environmental Significance 5.3 Principle 5.4 Materials Required 5.4.1 Apparatus Required 5.4.2
RBS detergents for laboratories
RBS detergents for laboratories High performance solutions For reliable and reproducible results Competence & experience RBS products are mainly intended for water-based cleaning processes of glassware
PRETREATMENT TECHNICAL DATA SHEET WATER EMULSIFIABLE RUST PREVENTATIVE PRODUCT DESCRIPTION
INDUSTRIAL COATINGS RA260 WATER EMULSIFIABLE RUST PREVENTATIVE PRODUCT DESCRIPTION is water emulsifiable rust preventative oil, which provides outstanding corrosion protection for all phosphate metals.
Anodizing by Constant Current Density
Anodizing by Constant Current Density By Charles A. Grubbs Technical Advisor Today, the modern anodizer is faced with challenges never before considered. The quest for Quality and reproducibility has become
NO TARN 15. 5) Can be used on Silver AND Gold. Protects gold from blackening during shipping due to reaction with box chemicals.
Description is an after-treatment process which effectively protects Silver from oxidation and tarnishing. Used as directed, it forms a thin, invisible film on the surface which blocks exposure to the
ph Measurements of Common Substances
Chem 100 Section Experiment 10 Name Partner s Name Introduction ph Measurements of Common Substances The concentration of an acid or base is frequently expressed as ph. Historically, ph stands for the
Question Bank Electrolysis
Question Bank Electrolysis 1. (a) What do you understand by the terms (i) electrolytes (ii) non-electrolytes? (b) Arrange electrolytes and non-electrolytes from the following substances (i) sugar solution
Sulfites for Oxygen Control
If you would like a more detailed version of this report, please request SOS from [email protected] along with your e-mail address. A. Introduction Sulfites for Oxygen Control Robert R. Cavano
UNIT 4 METAL COATING PROCESSES
UNIT 4 METAL COATING PROCESSES Structure 4.1 Introduction Objectives 4.2 Metal and Non-metal Coatings 4.2.1 Metallic Coatings 4.2.2 Non-Metallic Coatings 4.3 Electroforming 4.4 Galvanizing 4.5 Anodizing
THE USE OF OZONATED HF SOLUTIONS FOR POLYSILICON STRIPPING
THE USE OF OZONATED HF SOLUTIONS FOR POLYSILICON STRIPPING Gim S. Chen, Ismail Kashkoush, and Rich E. Novak AKrion LLC 633 Hedgewood Drive, #15 Allentown, PA 1816, USA ABSTRACT Ozone-based HF chemistry
Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate
Cantaurus, Vol. 7, 5-8, May 1999 McPherson College Division of Science and Technology Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate Janet Bowen ABSTRACT Sulfate is used in
Chapter 8: Chemical Equations and Reactions
Chapter 8: Chemical Equations and Reactions I. Describing Chemical Reactions A. A chemical reaction is the process by which one or more substances are changed into one or more different substances. A chemical
Chemistry at Work. How Chemistry is used in the Water Service
Chemistry at Work How Chemistry is used in the Water Service WATER TREATMENT Everyday, more than 100 water treatment works in Northern Ireland put approximately 680 million litres of water into the supply
Anodizing Aluminum. By J.C. HECKER, JR. Aluminum Consultants Madison, Wisconsin
Anodizing Aluminum By J.C. HECKER, JR. Aluminum Consultants Madison, Wisconsin Anodizing, unlike electroplating and organic coatings, is commercially unique to aluminum. Developed in the early 1930 s,
A Potentiometric Analysis of Fluoride Ion in Toothpaste
CHEM 311L Quantitative Analysis Laboratory Revision 2.0 A Potentiometric Analysis of Fluoride Ion in Toothpaste In this laboratory exercise, we will analyze a toothpaste sample for its Fluoride Ion (F
RAPID FIXER FACT SHEET A LIQUID RAPID FIXER FOR BLACK AND WHITE FILMS AND PAPERS. August 2002
FACT SHEET RAPID FIXER August 2002 A LIQUID RAPID FIXER FOR BLACK AND WHITE FILMS AND PAPERS ILFORD RAPID FIXER is a non-hardening rapid fixer supplied as a liquid concentrate that is diluted with water
PAINTING OVER HOT DIP GALVANIZED STEEL
PAINTING OVER HOT DIP GALVANIZED STEEL Thomas J. Langill, Ph.D., Technical Director American Galvanizers Association 12200 E. Iliff Ave. Suite 204 Aurora, CO 80014 Abstract: Duplex systems, also known
The chemical components of detergents and their roles in the washing process
The chemical components of detergents and their roles in the washing process Laundry detergents are formulated from six groups of substances :. surfactants. builders. bleachingagents. enzymes. fillers.
Removing Heavy Metals from Wastewater
Removing Heavy Metals from Wastewater Engineering Research Center Report David M. Ayres Allen P. Davis Paul M. Gietka August 1994 1 2 Removing Heavy Metals From Wastewater Introduction This manual provides
Metal Finishing: How to Save on Alkaline Cleaners, Acids, and Rinse Water May 10, 2011 Dave Fister, Senior Staff Engineer
Metal Finishing: How to Save on Alkaline Cleaners, Acids, and Rinse Water May 10, 2011 Dave Fister, Senior Staff Engineer New York State Pollution Prevention Institute at Rochester Institute of Technology
Estimation of Alcohol Content in Wine by Dichromate Oxidation followed by Redox Titration
Sirromet Wines Pty Ltd 850-938 Mount Cotton Rd Mount Cotton Queensland Australia 4165 www.sirromet.com Courtesy of Jessica Ferguson Assistant Winemaker & Chemist Downloaded from seniorchem.com/eei.html
Self Assessment Exercise
Self Assessment Exercise Read the following extract of supporting documentation for Permit Application for Galvos plc galvanising facility and the accompanying tables. Decide if the proposed control techniques
Measurement by Ion Selective Electrodes
Measurement by Ion Selective Electrodes Adrian Vazquez May 8, 2012 Why Use Ion Selective Electrodes? Responsive over a wide concentration range Not affected by color or turbidity of sample Rugged and durable
THE NWF WATER PURIFICATION PROCESS FRESH WATER IN A NATURAL WAY. Esko Meloni Ferroplan Oy
THE NWF WATER PURIFICATION PROCESS FRESH WATER IN A NATURAL WAY Esko Meloni Ferroplan Oy 1 The NWF Water Purification Process: list of contents 1. NWF biological purification of groundwater Iron and manganese
Milwaukee USER MANUAL
Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: MW600 Smart DO Meter PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery compartment cover on the back of the
the runnerless types of molds are explained post molding operations are described the basic methods of applied decoration methods are examined
Training Objectives After watching the video and reviewing this printed material, the viewer will gain knowledge and understanding of the various plastic finishing processes used in industry and their
ZINCROLYTE VS DUPLEX 700
TEST REPORT Date: 03-05-2012 Reference: Duroc NV Corrosion Protection Moerelei 149 2610 Antwerp Belgium Written by: Ing. Martijn Wirken - [email protected] ZINCROLYTE VS DUPLEX 700 This document is not legally
White rust on galvanized and galvanized pre-painted steel. Technical Information
Technical Information White rust on galvanised steel Prevention It is easier to prevent white rust than to cure it! Reasonable precautions to protect steel during both transport and storage can considerably
Neutral type Auto-Catalytic Electroless Gold Plating Process Abstract 1. Introduction 2. Experiment and Results
Neutral type Auto-Catalytic Electroless Gold Plating Process Don Gudeczauskas, Uyemura International Corporation Seiji Nakatani, Masayuki Kiso, Shigeo Hashimoto, C.Uyemura & Co., Ltd Abstract In order
Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls
Nitrate DOC316.53.01066 Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific
Sergey L. Belopukhov Department of Inorganic and Analytical Chemistry. K.A.Timirjazev Moscow Agricultural Academy. E-mail: belopuhov@imail.
Thematic Division: Physico-Chemical Studies. Full Paper Subdivision: Chemical Technology. Registration Code of Publication: po34 Note: The previous communication of this series see in Butlerov Communications
Wastewater Reuse. Typical treated wastewater is:
Wastewater Reuse Most metal finishing industries have in-house wastewater treatment to economically dispose of the acids, alkali, oils, and dissolved metals in the rinse water and occasional tank solution
Dissolved and precipitated oxalate
Accepted 2005 Process liquors from bleach plants Dissolved and precipitated oxalate Using Ion Chromatography 0 Introduction In bleach plants of pulp mills with a high degree of system closure, there is
AESF Aerospace / Airline Plating Forum - Tulsa, OK.
AESF Aerospace / Airline Plating Forum - Tulsa, OK. The following is condensed from a White Paper presented by C.T. (Tom) Philipp, P.E., at the Aerospace/Airline Plating Forum in Tulsa, OK. This paper
Standard methods in water analysis
Branch General analytical laboratories; water analysis Keywords Water analysis; standard methods; ASTM; DIN; ISO; USP; EPA; SLMB; EN; SCA; titration; ion chromatography; voltammetry; branch 1; branch 2
SenTix 950 SenTix 980
SenTix 950 SenTix 980 ph combination electrodes with refillable liquid reference system Operating manual ba75843e01 08/2009 SenTix The latest version of the present operating manual can be found on the
Operator Quick Guide EC SENSOR
Operator Quick Guide EC SENSOR Revision G - 24/04/2008 General Information About This Guide The information in this guide has been carefully checked and is believed to be accurate. However, Hach Ultra
TECHNICAL DATA SHEET DURO HARD CHROME PLATING PROCESS
TECHNICAL DATA SHEET Duro hard chrome plating process is a high-speed bath which employs a special mixed soluble catalyst and has been developed to meet the modern hard chrome plating requirements. Its
Hands-On Labs SM-1 Lab Manual
EXPERIMENT 4: Separation of a Mixture of Solids Read the entire experiment and organize time, materials, and work space before beginning. Remember to review the safety sections and wear goggles when appropriate.
Conductivity of silicon can be changed several orders of magnitude by introducing impurity atoms in silicon crystal lattice.
CMOS Processing Technology Silicon: a semiconductor with resistance between that of conductor and an insulator. Conductivity of silicon can be changed several orders of magnitude by introducing impurity
ION EXCHANGE FOR DUMMIES. An introduction
ION EXCHANGE FOR DUMMIES An introduction Water Water is a liquid. Water is made of water molecules (formula H 2 O). All natural waters contain some foreign substances, usually in small amounts. The water
SCH 4C1 Unit 2 Problem Set Questions taken from Frank Mustoe et all, "Chemistry 11", McGraw-Hill Ryerson, 2001
SCH 4C1 Unit 2 Problem Set Questions taken from Frank Mustoe et all, "Chemistry 11", McGraw-Hill Ryerson, 2001 1. A small pin contains 0.0178 mol of iron. How many atoms of iron are in the pin? 2. A sample
Process Specification for the Anodizing of Aluminum Alloys
Process Specification for the Anodizing of Aluminum Alloys Engineering Directorate Structural Engineering Division May 2003 National Aeronautics and Space Administration Lyndon B. Johnson Space Center
Lab 7 Soil ph and Salinity OBJECTIVE INTRODUCTION Soil ph active
Lab 7 Soil ph and Salinity OBJECTIVE In this lab you will learn the effect of the concentration of hydrogen ions (ph) and various salts on the fertility of a soil. You will perform some tests which are
AN EXPERIMENT IN ALCHEMY: COPPER TO SILVER TO GOLD 2005, 2000, 1996 by David A. Katz. All rights reserved
AN EXPERIMENT IN ALCHEMY: COPPER TO SILVER TO GOLD 2005, 2000, 1996 by David A. Katz. All rights reserved INTRODUCTION One of the goals of the ancient alchemists was to convert base metals into gold. Although
IMO Approved Tank Cleaning Chemicals
IMO Approved Tank Cleaning Chemicals IMO Approved Tank Cleaning Chemicals TC1 Aquamarine Aquawash T1080A Suitable for the removal of fatty acids, fish oils and other drying or semi-drying oil deposits.
Apr 17, 2000 LAB MANUAL 1811.0
Apr 17, 2000 LAB MANUAL 1811.0 1811 BULK SPECIFIC GRAVITY (GMB) AND DENSITY OF COMPACTED BITUMINOUS SPECIMENS USING PARAFFIN OR PARAFILM ASTM Designation D 1188 (MN/DOT Modified) 1811.1 SCOPE This test
Additional Lecture: TITRATION BASICS
Additional Lecture: TITRATION BASICS 1 Definition and Applications Titration is the incremental addition of a reagent solution (called titrant) to the analyte until the reaction is complete Common applications:
Best Practice in Boiler Water Treatment
Best Practice in Boiler Water Treatment Boiler Water Treatment Part 2 Internal Treatment Objectives of Internal Water Treatment 1 To control the level of total dissolved solids (TDS) within the boiler
DRINKING WATER - LAB EXPERIMENTS. Coagulation and flocculation LAB EXPERIMENTS. Jartest
DRINKING WATER - LAB EXPERIMENTS LAB EXPERIMENTS Coagulation and flocculation Jartest coagulation and flocculation - jartest lab experiments Framework This module explains the lab experiment on coagulation
ph and CONDUCTIVITY ph and conductivity in fountain solution are necessary for plate humidification.
ph and CONDUCTIVITY ph and conductivity in fountain solution are necessary for plate humidification. CONTROL OF VARIATIONS OF FOUNTAIN SOLUTION CONCENTRATE FOR A BETTER PRINTING QUALITY Two major control
The Owners Coated Coil, Cleaning and Maintenance Service Manual.
The Owners Coated Coil, Cleaning and Maintenance Service Manual. Revision: July, 2011 Section INDEX Pages Forward 1 2 Importance of Proper & Timely Coil Cleaning 3 Coil Cleaner Characteristics 4 Selecting
A Primer on Protecting Idle Boilers By Howard Benisvy, Member ASHRAE
The following article was published in ASHRAE Journal, December 2002. Copyright 2002 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. It is presented for educational purposes
Laboratory Glassware Cleaning
Laboratory Glassware Cleaning Laboratory glassware is valued for its durability, inertness, transparency and for presenting a simple, clean surface for a variety of applications. It is important that lab
DYES AND DYEING 2003 by David A. Katz. All rights reserved. Permission for classroom use provided original copyright is included.
DYES AND DYEING 2003 by David A. Katz. All rights reserved. Permission for classroom use provided original copyright is included. Dyeing of textiles has been practiced for thousands of years with the first
Experiment 8 - Double Displacement Reactions
Experiment 8 - Double Displacement Reactions A double displacement reaction involves two ionic compounds that are dissolved in water. In a double displacement reaction, it appears as though the ions are
GUIDELINES FOR LEACHATE CONTROL
GUIDELINES FOR LEACHATE CONTROL The term leachate refers to liquids that migrate from the waste carrying dissolved or suspended contaminants. Leachate results from precipitation entering the landfill and
Decomposition. Composition
Decomposition 1. Solid ammonium carbonate is heated. 2. Solid calcium carbonate is heated. 3. Solid calcium sulfite is heated in a vacuum. Composition 1. Barium oxide is added to distilled water. 2. Phosphorus
LACHAT METHOD NUMBER 10-204-00-5-D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately 3-500 g CN/L 2-500 g CN/L. 09e
1 SIDE BY SIDE COMPARISON TABLE FOR THE DETERMINATION OF CYANIDE BY UV DIGESTION AND AMPEROMETRIC DETECTION FIA METHOD - 10-204-00-5-D (ASTM D7511-09 e ) TOPIC Method ASTM D7511-09e LACHAT METHOD NUMBER
Conductivity and TDS Meters
Table of Contents Comparison Charts Introduction Portable Meters Waterproof Meters Printing & Logging Portable Meters Bench Meters Combination EC/TDS/pH Meter Page G2 G3 G6 G11 G14 G15 G16 G1 Comparison
DURAPOSIT TM SMT 810 Electroless Nickel
DURAPOSIT TM SMT 810 Electroless Nickel For PWB Metallization Applications Regional Product Availability Asia Japan/Korea North America Europe Description DURAPOSIT TM SMT 810 is an electroless nickel
Chemical equilibria Buffer solutions
Chemical equilibria Buffer solutions Definition The buffer solutions have the ability to resist changes in ph when smaller amounts of acid or base is added. Importance They are applied in the chemical
STANDARD PHOTOGRAPHIC PRINTING 08/10. 1.5 minutes to 3 minutes. HCA (hypoclearing agent): *rapid washing agent. 20 minutes at 65-80 degrees
STANDARD PHOTOGRAPHIC PRINTING 08/10 Work with 32 oz. of solution in each tray depending upon tray size. Agitate paper when in trays DEKTOL: 1.5 minutes to 3 minutes STOP: 30 seconds USED FIXER: 3 minutes
LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)
October 2006 RESTRICTED LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006) DRAFT FOR DISCUSSION World Health Organization 2006 All rights reserved. This draft is intended for
ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND
#3. Acid - Base Titrations 27 EXPERIMENT 3. ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND Carbonate Equilibria In this experiment a solution of hydrochloric
CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor
CONDUCTIVITY SENSOR Description D0382 Figure 1. The Conductivity Sensor Short Description The Conductivity Sensor can be used to measure either solution conductivity or total ion concentration of aqueous
Product list Magnesium, Calcium and further mineral compounds
Product list Magnesium, Calcium and further mineral compounds Product list Magnesium, Calcium and further mineral compounds A Aluminium stearate Aluminium sulphate C Calcium acetate Calcium ascorbate L-Calcium
ACO Cleaning principles for drainage
Cleaning procedures ACO Cleaning principles for drainage Page Introduction 3 Principles of cleaning 4 Cleaning procedures ACO cleaning principles for drainage Cleaning chemicals 5 Manual cleaning of drainage
SOFIA UNIVERSITY ST. KLIMENT OHRIDSKI Faculty:...Chemistry and Pharmacy... Subject area: (code and name) C H L 3 8 2 4 1 3
Approved by:.. Dean Date... SOFIA UNIVERSITY ST. KLIMENT OHRIDSKI Faculty:...Chemistry and Pharmacy... Subject area: (code and name) C H L 3 8 3...Pharmacy... M.Sc. Program: (code and name) C H L 3 8 3...Pharmacy...
HOMEWORK 4A. Definitions. Oxidation-Reduction Reactions. Questions
HOMEWORK 4A Oxidation-Reduction Reactions 1. Indicate whether a reaction will occur or not in each of following. Wtiring a balcnced equation is not necessary. (a) Magnesium metal is added to hydrochloric
Etching Etch Definitions Isotropic Etching: same in all direction Anisotropic Etching: direction sensitive Selectivity: etch rate difference between
Etching Etch Definitions Isotropic Etching: same in all direction Anisotropic Etching: direction sensitive Selectivity: etch rate difference between 2 materials Other layers below one being etch Masking
Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater
Document: AND Sol Env 08 2013 Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater Matrix specific sample preparation and testing methods for environmental waters
Measuring volume of gas produced Measuring precipitation (because sulphur is produced) e.g. look for X to disappear Measure mass lost
Introduction My investigation is about the rate of reaction. A rate of reaction is defined as how fast or slow a reaction takes place. For example, the oxidation of iron under the atmosphere is a slow
Guidelines for Durable Driveways, Carports Patios, Walks, Garage Floors
Guidelines for Durable Driveways, Carports Patios, Walks, Garage Floors The Right Concrete Mix Placing and Finishing Joints Correctly Spaced Curing for Durability "Concrete durability is the ability to
Safety Safety glasses or goggles must be worn in the laboratory at all times.
APPLE BROWNING: A STUDY OF OXIDATION OF FOODS 2005, 1997 by David A. Katz. All rights reserved. Reproduction permitted for education use provided original copyright is included. You are preparing for a
HS 1003 Part 2 HS 1003 Heavy Metals Test
HS 1003 Heavy Metals Test 1. Purpose This test method is used to analyse the heavy metal content in an aliquot portion of stabilised hot acetic acid extract by Atomic Absorption Spectroscopy (AAS). Note:
Magnesium (II), Sodium (I), Potassium (I), Ammonium (I)
s (The Soluble Group) Magnesium (II), Sodium (I), Potassium (I), Ammonium (I) The salts of the cations of group V, with few exceptions, are quite soluble, this accounts for the fact that there is no common
Form and content of COOMET сertificate for reference materials for composition and properties of substances and materials
COOMET Recommendation Form and content of COOMET сertificate for reference materials for composition and properties of substances and materials CООМЕТ R/RM/22:2013 Agreed at the 17 th meeting of COOMET
PROCESSING THE RADIOGRAPH. Neill Serman. Sept. 2000 W + P. Chapter 6
1 PROCESSING THE RADIOGRAPH. Neill Serman. Sept. 2000 W + P. Chapter 6 THE STAGES IN THE PRODUCTION OF THE RADIOGRAPH Many dentists who utilize manual processing, intentionally over expose patients and
ph Measurement and Control
ph Measurement and Control Tech Tip #14 1997 I. The Need for ph II. ph System Requirements III. ph Electrode Conditioning Procedures IV. How the electrode works V. Identifying the Electrode Components
DURABILITY OF MORTAR LININGS IN DUCTILE IRON PIPES Durability of mortar linings
DURABILITY OF MORTAR LININGS IN DUCTILE IRON PIPES Durability of mortar linings I. S. MELAND SINTEF Civil and Environmental Engineering, Cement and Concrete, Trondheim, Norway Durability of Building Materials
Determination of the amount of sodium carbonate and sodium hydroxide in a mixture by titration.
Module 9 : Experiments in Chemistry Lecture 38 : Titrations : Acid-Base, Redox and Complexometric Objectives In this lecture you will learn the techniques to do following Determination of the amount of
Technical Information DF30
Technical Information DF30 Performance Pigments and Colors Lead Free Onglaze Colours for Porcelain, Bone China, Vitreous China, Earthenware, and Enamel In this leaflet, Ferro presents SAMBA100, the next
How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *
How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work * 1. Oxygen sensor detection principle Most portable or survey instruments used for workplace evaluation of oxygen concentrations
STERILIZATION AND DISINFECTION
STERILIZATION AND DISINFECTION Importance of hand washing shown by Semmelweis STERILIZATION A physical or chemical process that destroys or eliminates all forms of microbial life, including spores. A satisfactory
Chapter 16: Tests for ions and gases
The position of hydrogen in the reactivity series Hydrogen, although not a metal, is included in the reactivity series because it, like metals, can be displaced from aqueous solution, only this time the
WESTERN BLOTTING TIPS AND TROUBLESHOOTING GUIDE TROUBLESHOOTING GUIDE
WESTERN BLOTTING TIPS AND TROUBLESHOOTING GUIDE TIPS FOR SUCCESSFUL WESTERB BLOTS TROUBLESHOOTING GUIDE 1. Suboptimal protein transfer. This is the most common complaint with western blotting and could
Paper No. 4071 APPLICATION OF EQCM TO THE STUDY OF CO2 CORROSION
Paper No. 471 APPLICATION OF EQCM TO THE STUDY OF CO2 CORROSION Yang Yang, Bruce Brown and Srdjan Nešić Institute for Corrosion and Multiphase Technology, Department of Chemical and Biomolecular Engineering
Ion Selective Electrodes
Ion Selective Electrodes OAKTON has a large selection of Ion Selective Electrodes () to suit a wide variety of applications. Each electrode has a typical response time of 20 to 30 seconds but will vary
