1 NOW also for use in hazardous areas! RedGuard RedGuard Temperature Monitoring System
2 RedGuard Temperature Monitoring System Locate risks - fast and precise Plant safety and reliability, accident prevention and process and product quality are today the top themes in industrial plants. In every respect, the processes must assure the ultimate in safety and reliability. Safety measures are top priorities particularly in plants with an increased danger potential, such as for example in the chemicals and pharmaceutical industries, in the area of oil & gas, in power stations, in the fodder industry and of course in mining. Temperature monitoring is a highly charged issue. Overheating, fires and leakages can cause immense damage. The earlier the risk is recognised and can be localised, the higher the chance of preventing damage to people, machinery and the environment. 2
3 RedGuard Temperature Monitoring System The patented RedGuard Temperature Monitoring System offers an easy and safe temperature monitoring solution for hazardous areas too. The RedGuard system design is simple and consists in principle of a sensor cable with integrated sensors and a processor unit. The processor unit registers and analyses the temperature readings values from up to 250 temperature sensors. Whenever the preset threshold readings are exceeded, the system generates an alarm. Applications and areas of use Monitoring of leakage and fire Operating range: energy tunnels and cable ducts Monitoring of temperature in pipes and containers Operating range: process industry, chemicals, pharmaceuticals, oil and gas Leakage, temperature and fire monitoring Operating range: refilling stations and tank farms for flammable liquids Features of the RedGuard System Sensor spacing freely selectable (2 m, 4 m, 7 m, 10 m, 20 m) Integrated sensor & control system with universal interfaces Wide measuring temperature range (-55 C to +125 C) Short system response time (< 5 seconds) Long-time stability, self-monitoring, maintenance-free Possibility of integrating sensors for other parameters Simple project planning, freely programmable system reaction 3
4 RedGuard System Design System design/components Sensor cable (SD/polyurethane or HD/fluoropolymer) Connection Filter Module (CFM) for connecting the input lead (CCA) to the sensor cable or connecting two sensor cable segments Protection Filter Module (PFM) protects sensors against undue voltages Cable Termination Module (CTM) to terminate the sensor cable Processor unit (SSP or SRG) Generic Sensor Interface (GSI) to connect external sensors Relay Control Unit (RCU) for controlling a further 32 relays to localize the alarm System design and connection plan CCA access cable GSI CFM/PFM Sensor cable SD or HD RCU SRG Power Alarm Fault External sensor CTM RS232 RS422 ModBus Relay output (32 + 8) Group alarm (1x) Fault (1x) AC 230/115 V 4
5 RedGuard System Design Function Sensor data in real time The processor unit (SSP/SRG) scans the sensor cable and converts the analog signals into temperature measurement values. The complete system is programmed with the RGCC configuration software. The TMON visualisation software is available for the visual presentation of the temperature profile on PC. Define specific treshold 4 threshold values can be defined for each sensor. A further 4 threshold values are freely settable over the complete length of the sensor cable. The sensor data and operating states are scanned in real time on the interfaces. This allows unusual states to be recognised immediately and forwarded or for the alarm to be triggered. Define treshold Power of hot spot Temperature at sensor position Reliable alarm and fault relay output The alarm can be programmed for latching or pulse mode. The relay contacts are controlled by means of the software or by hardware monitoring (watchdog). The yellow light diode is coupled with the fault and the red light diode is coupled with the alarm relay. Storage of the temperature readings All events are stored in a cyclic event logger. The event logger can be scanned through the serial interface. Furthermore, all events and also the sensor readings can be saved to a plug-in flash memory. This can be read by an external computer. It contains enough storage space to collect and file data for months.the system can be operated on its own or in combination with superordinate systems through serial interfaces. Integration of external sensors Additional external sensors can be connected through a sensor interface (GSI). 5
6 RedGuard System Components Sensor cable The sensor cable contains the entire electronics for measuring temperature, addressing the sensors and transmitting data to the processor unit. The sensor spacings are selectable: 2, 4, 7, 10 or 20 m. One unit can monitor up to 2000 metres of sensor cable. Design The sensor cable consists of an 8-strand flat cable: 2 as redundant conductors for ground, 2 for supply voltage, 2 for data transmission and 2 for addressing. The flat cable is protected by two additional covers. The inner thermoplastic elastomer jacket serves as a barrier to humidity and the outer polyurethane or fluoropolymer jacket is optimised for mechanical and chemical resistance. Technical data Sensor cable SD Sensor cable HD Outer jacket Polyurethane, red Fluorpolymer, grey Measuring temperature range -40 C up to 85 C -55 C up to 125 C Dimensions 5,8 x 13,8 mm 4,9 x 13, 5 mm Precision +/-2 C Sensitivity +/-0.05 C Calibration Calibration data are supplied for each sensor Sampling rate up to 100 sensors per second Response time < 5 seconds Electrical data Current consumption to 140 µa per sensor (typical) Mechanical data Protection class IP 66 Installation temperature +5 C up to +45 C Bending radius 100 mm Pulling strength 500 N during installation, 0N during operation Fastening Mounting clamps (ideal mounting spacing 1 m) for horizontal and vertical mounting on surface Labelling Sensor position, serial number, spacing, marking Connection technology insulation displacement connection with standard tools, 8-pole connectors, grid spacing: 1.27 mm Max. length of the sensor cable 500 m per cable reel Selection chart Sensor cable Sensorspacing Code no. 2 m 020 Complete order no. Please enter code number. 4 m 040 Sensor cable SD Polyurethane outer jacket CTS R0PURROBT1 7 m m m 200 Sensor cable HD Fluoropolymer outer jacket CTS R0FLUGRBT1 6
7 RedGuard System Components Processor unit The measurement values are evaluated in the SSP/SRG processor unit. The processor unit controls data communication, stores events and monitors the proper functioning of the system. The temperature sensors in the sensor cable are actuated sequentially, the measurements are read into a ring memory and analysed after every interrogation cycle. Depending on the user configuration of the RedGuard Software, the control unit can output an alarm on an LED and a relay and/or per data interface. The alarm events are configured by means of four threshold temperature values (min./max. absolute temperature or temperature gradient). These threshold readings can be set for the entire system and for each individual sensor. An algorithm allows configuration of up to 25 reaction patterns. Technical data Data memory Sampling rate Response time Interface Electrical data Supply voltage Output voltage relay Display cyclical event logger for the last 100 events, plug-in flash memory for several months, depending on memory capacity and sampling interval up to 100 sensors per second < 5 seconds RS232/RS422 or ModBus 12/24 V up to max. 250 V, 6 A LED green: supply; LED red: alarm; LED yellow: fault Mechanical data Operating temperature range -25 C to +85 C Dimensions SSP 200 x 150 x 74 mm (without cable entry) SRG 240 x 160 x 90 mm (without cable entry) RCU 240 x 160 x 90 mm (without cable entry) Material polycarbonate Protection class IP 65 Connection technology insulation displacement connection technology with standard tools, 8-pole connectors, grid spacing: 1.27 mm Selection chart Processor unit Description processor unit Order no. with 2 relay outputs without internal protection filter module MSSP00R0PCAROBT1 with additional 8 relay outputs and inputs without internal protection filter module MSRG00R0PCAROBT1 with 2 relay outputs with internal protection filter module MSSP10R0PCAROBT1 with additional 8 relay outputs and inputs with internal protection filter module MSRG10R0PCAROBT1 Relay control unit with further 32 relays to realize the alarm MRCU0000PCAROBT1 ModBus Interfaces Full-duplex MMBI0003 Half-duplex MMBI0103 7
8 RedGuard System Components Connection and termination modules The connection filter module (CFM) serve to connect the access cable (CCA) to the sensor cable or to combine two sensor cable segments. The protection filter module PFM protects sensors in the cable against undue voltages. The cable termination module (CTM) serves to terminate the sensor cable. Additional external sensors can be connected through a generic sensor interface (GSI); max. 4 sensors per GSI module. Technical data Electrical data Current consumption Input voltage/current CFM: 0 ma PFM: 5 ma (typical) CTM: 5 ma (typical) GSI sensors with 0 to 10 V or 4 to 20 ma CTM CFM/PFM Mechanical data Operating temperature range -40 C to +85 C Dimensions 110 x 75 x 56 mm (without cable entry) Material glass-fibre reinforced polyester enclosure, grey Protection class IP 66 Connection technology insulation displacement connection technology with standard-tools, 8-pole connectors, grid spacing: 1.27 mm Selection chart Connection and Termination Modules Designation Order no. CTM Cable Termination Module MCTM00R0PEFGRBT1 CFM Connection Filter Module MCFM00R0PEFGRBT1 PFM Protection Filter Module MPFM00R0PEFGRBT1 GSI Generic Sensor Interface MGSI00R0PEFGRBT1 Accessories Selection chart Accessories Designation Voltage source 85 to 264 V/ 24 V, 1 A Rail DIN Voltage source 100 to 240 V/ 24 V, 0.9 A CCA input lead Mounting clamps, VP 100 pcs. Mounting tool Order no. VAC100 VAC102 VAC010 VAC020 VAC090 8
9 RedGuard System Components Software The RGCC (RedGuard Control Center) software is simply installed on a WINDOWS operating system (2000 and XP). This software offers all functionalities for safely configuring, operating and maintaining the RedGuard System: Output of the entire set of a plant s parameters to a PDF document (reporting) Project-related administration and traceability of all plant data and interventions Sensor calibration: recalibration in the field, assignment of the calibration data to the sensors Easy programming of the threshold readings with the aid of the reaction matrix Configuration of the relay output (logical equations) Administration and interpretation of the event logger (LOG data) Graphic display with zoom and pan functions Data certification The history of every log and configuration file is always traceable. Each file has a content-dependent code, with which the authenticity of the contents can be verified. External data analysis Data can be read into a standard table calculation program. This allows, for example, sensor values that correspond to particular critical operating states in the plant to be registered and presented,. Project management Several processor units can be combined for projects. Order numbers Software Configuration Software RGCC PRGCC0003BT1 9
10 RedGuard Temperature Monitoring System ATEX Version Temperature sensor unit CTU-2 for zone and zone For applications in hazardous areas we offer you a special configuration of the RedGuard temperature monitoring system. The Ex version conforms to ATEX Directive 94/9/EC and is tested and approved for use in gas areas (zone 1) and dust areas (zone 21). The CTU-2 temperature sensor unit conforms to Equipment Category II 2G and II 2D and can be used directly in hazardous areas. The SSP or SRG processor unit is installed outside the hazardous area and is equipped with current and overvoltage protection. System design and connection plan CCA access cable GSI CFM-2 Sensor cable SD-2 or HD-2 SSP Power Alarm Fault External sensor Temperature sensor unit CTU-2 CTM-2 RS232 RS422 ModBus Alarm Fault AC 230/115 V Safe area Zone 1, 21 Technical data Explosion protection II 2G Ex e mb II T6/T5/T4/T3 II 2D Ex td A21 80 C/T95 C/T120 C/T140 C IBExU07ATEX1149 X Protection class IP 65 Operating temperature -40 C to +65 C Ambient temperature SD-2-40 C to +70 C HD-2-55 C to +105 C /125 C Supply voltage (CTU-2) 20 V Current consumption (CTU-2) < 32 ma Switching capacity relay max. 20 watts Output voltage 9 to 50 V Outer jacket sensor cable SD-2 polyurethane, red HD-2 fluoropolymer, grey Enclosure material Connection and termination module Polyester, black 10
11 BARTEC protects people and the environment by the safety of components, s y s t e m s and plants. BARTEC GmbH Germany Max-Eyth-Straße Bad Mergentheim Phone: Fax: [email protected] UK-D-BCS /10-BARTECWerbeAgentur
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Isolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
ALARMLINE ANALOGUE Linear Heat Detection System
ALARMLINE ANALOGUE Alarmline Analogue sensor cable senses temperature variations by continuously monitoring the resistance of specially doped N.T.C. polymeric insulation. A change in temperature produces
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
Table of Contents. TransformerIQ FAQs 1
[12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
L-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
3500/93 System Display
3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide
SMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
SMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
WEATHER STATION FOR SOLAR FARM MONITORING
WEATHER STATION FOR SOLAR FARM MONITORING SOLAR FARM MONITORING SYSTEM: Measures global, horizontal, & background irradiance. Measures wind speed, wind direction, ambient temperature, and relative humidity.
PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW
PROCESS AUTOMATION OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS Industrial Monitors And HMI Solutions PRODUCT OPERATING AND MONITORING wherever you want The Pepperl+Fuchs HMI
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
HARTING mcon 1000 Introduction and features
Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)
VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS
VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS CEMB SPA Via Risorgimento, 9 Mandello del Lario (Lc), Italy [email protected] www.cemb.com INSTRUMENT FOR MONITORING VIBRATIONS OF FANS INSTALLED IN ROAD
Product Information Fire alarm panel 8000 C
Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Instruction Manual Service Program ULTRA-PROG-IR
Instruction Manual Service Program ULTRA-PROG-IR Parameterizing Software for Ultrasonic Sensors with Infrared Interface Contents 1 Installation of the Software ULTRA-PROG-IR... 4 1.1 System Requirements...
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
WEB log. Device connection plans
WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20160425* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring
LNG Monitoring Fiber-Optic Leakage Detection System Pipeline leakage detection Regasification and liquefaction monitoring Tank annulus and base slab monitoring Spill containment control Intelligent Solutions
Interface Level And Point Level Analyzers & Sensors
Interface Level And Point Level Analyzers & Sensors Model 2511 Analyzer Model 2505 System Model 2120 System Royce now offers a complete line of Interface Level and Point Level Analyzers that make it possible
Protection Systems. A UTC Fire & Security Company F-73-01. Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS
Effective: May 2007 AlarmLine TM R Protection Systems Linear Heat Detector A UTC Fire & Security Company F-73-01 FEATURES Integrating Type Linear Heat Detector Analog Sensing Field Adjustable Alarm Set
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation
DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
Type testing 07.09.2006
I G R Interessengemeinschaft Regelwerke Technik Editor: R&M Prozesstechnik GmbH MSR- und Analysentechnik, D 710 M. Dietz 069 / 305-26 63 Kompetenzcenter EMR Test report no. IGR 110615 Type testing 07.09.2006
6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding
circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),
Instructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6
L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution
Product Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: [email protected] Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual
Freeze Protection Thermostats MODELS SST 2 Part Number 22744 MANUAL We Manage Heat Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 (574)
PD 100A. Printing data system
PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
A good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P
SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P 2 Alarm Levels Bargraph + LED Indication of Gas Concentration Visual and Audible Signalization of Activated Alarm Levels 2 SPDT 5A/250V Output Relays Shock-Proof
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene
Weighing terminals The stainless steel weighing terminals of the 4 Series: IND429, IND439 and IND449 The optimal solution for demanding applications in the food, pharmaceutical and chemical industries.
The flexible performer: ALS 306
The flexible performer: ALS 306 The new labelling generation for your efficient product identification The perfect fit For highly demanding brands... The power of brands People know your products. Your
Introduction. Refrigerant Leak Detecting System. Feature and Benefits
PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
S300 Series Dust Monitors
S301 DustGuard S303 Trend Monitor S304 Emission Monitor S305 Stack Monitor Intrinsically Safe (ATEX) Dust Monitors Split Architecture (Remote)Models Data Logging Software S300 Series Dust Monitors Dust
Shunt lock function 3066
Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
OZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
ABB i-bus EIB Logic Module LM/S 1.1
Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...
400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
Distributed Temperature Monitoring of Energy Transmission and Distribution Systems
1 m 40000m0 range 61850 IEC spatial resolution Distributed Temperature Monitoring of Energy Transmission and Distribution Systems Ensuring a Reliable Supply of Electrical Power for Today s World www.en-sure.pro
Standard Buccaneer - USB
IP68 rated USB version 2.0 performance Plug and play capability Visual mating indication Shielded system Single and double ended cables Screw coupling PCB versions Dust and waterproof sealing when mated
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
WEB log. Device connection plans
WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20151210* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,
Programmable Controller G Series. New. Models
Programmable Controller G Series The IMO G6 is a very compact modular programmable controller offering extremely high performance. It is ideal for all applications from process control to machine control
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
In-Sight Hardware specifications
specifications In-Sight 5000, 5100, 5400, 5400S, 5400C, 5401, and 5403 4020 Linz/Austria Pummererstr. 36 Tel.: +43-(0)70-7646-0* www.schmachtl.at Memory Job/Program 16MB non-volatile flash memory; Unlimited
AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1
Product Manual ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Intelligent Installation Systems This manual describes the function of the EIB monitoring module EUB/S 1.1 with the Application program
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE
Series Circuit Breaker Monitors CONSOLIDATED Electronics, Inc. MONITORING THE FUTURE Why SF Gas Density Monitors? 6 Cut Maintenance Costs Your capital investment may be recovered with the elimination of
Early Fire Detection & Condition Monitoring
Early Fire Detection & Condition Monitoring Thermal Imaging Systems for Monitoring of Industrial Facilities in EX-/Non-EX-Zones Early Fire Detection of Large-Area Installations Thermal Condition Monitoring
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data
KACO-monitoring watchdog insight prolog Integrated monitoring available Monitor up to 32 inverters per prolog Reliable and accurate data Email alarms to maximize uptime Historical, current and production
Users manual. TCW181B-CM_R1 Page 1
Ethernet controller TCW181B-CM Users manual 1. Short description TCW181B-CM is 8-channel Ethernet relay board, which is designed to work in IP-based networks and managed by WEB interface or SNMP programs.
Original instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Model CU100: non-invasive installation flowmeter, with transducers installed outside the pipe Installation in horizontal or vertical pipe Easy and
Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes
SI-COLO Series SI-COLO2-LWL-HAMP-COL4 - Big measuring range: typ. 25 mm... 40 mm (with optical fiber and attachment optics KL-14 or KL-17) - Large assortment of optical fibers available (reflected or transmitted
1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions
Facility Pilot Server Art. No. : FAPV-SERVER-REG Facility Pilot Server Art. No. : FAPVSERVERREGGB Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
ISpac isolators. the perfect system
ISpac isolators the perfect system 2 safe isolation Handling flammable and potentially explosive substances is part and parcel of everyday operations in many branches of industry. However, it is not possible
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
Technical Information
Technical Information TI No. WL 80-63 E April 2001 Rolling Bearing Diagnosis with the FAG Bearing Analyser Rolling Bearings State-Of-The-Art, Condition-Related Monitoring of Plants and Machines Unforeseen
/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.
56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING
Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management
Energy Depot GmbH Delivering Solutions for Energy Management PRODUCT AND APPLICATION GUIDE Total Monitoring Solution for PV SOLAR LOGGER & ANALYSIS DC STRING MONITORING Residential Comprehensive Solar
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog