Welcome to the presentation of the Hybrid Trolley-Bus

Size: px
Start display at page:

Download "Welcome to the presentation of the Hybrid Trolley-Bus"

Transcription

1 Welcome to the presentation of the Hybrid Trolley-Bus Fitted with an electrical combined storage unit and used for Public Transportation O-Bus Nr. 029, Typ: ÖAF Gräf & Stift NGE 152 M17 hybrid, BBG Eberswalde, Ecologically friendly and energy-efficient solution RWS_trolleybus_hybrid_B.doc Seite 1/20

2 1. Introduction Motivation for the use of the combined storage Use of braking energy Increase the energy efficiency Reduction of current peaks from the catenary Quiet catenary-free operation Approach: Replacment of the emergency dieselgenerator by a combined storage RWS_trolleybus_hybrid_B.doc Seite 2/20

3 2. Operating diagramm hybrid system RWS_trolleybus_hybrid_B.doc Seite 3/20

4 3. Electrical equipment of the vehicle 3.1 The diesel engine generator unit was dismantled thus providing free space for the combined storage unit to be installed to. The fixing points remain the same ones. 600 VDC diesel engine generator unit for emergency drive mode Combined storage unit Installation situation Electronic drive/ braking control unit Switch cabinet Display of hybrid control system 600 VDC link on the capacitor plate Vossloh Kiepe RWS_trolleybus_hybrid_B.doc Seite 4/20

5 3.2. A switch cabinet has been installed for the electronic control of the hybrid system. As a result there will be one seat less than before (out of a total of 46 seats). A seat was removed and mounted at that location, the new switch cabinet. RWS_trolleybus_hybrid_B.doc Seite 5/20

6 3.3. Display in the driver s cabin Display of the hybrid control system in the driver s cabin LED display : Hybrid control system On Alert smoke detector Fault indication hybrid control system Luminous: power reduction in emergency mode Flashing: switch-off routine still on 0 100% Charging condition of traction battery RWS_trolleybus_hybrid_B.doc Seite 6/20

7 4. Construction of switch cabinet of the hybrid system Smoke detector MCU 1 und MCU 2 for cell management of BoostCap und Li-Batterie Main Computer AutoBox by the company dspace Signal coupler Control for startup precharge Output contactor, output fuses 24 V power supply, 24 V fuses, on/off control Contactor control Resistors and contactors for 600 V DC startup precharge EMC filter DC/DC Converter for the BoostCap-Battery DC/DC Converter for the Lithium-Battery Room for the Cable inlet RWS_trolleybus_hybrid_B.doc Seite 7/20

8 5. Construction of electrical combined storage unit 5.1. General view of the electrical combined storage unit ventilator 3 ventilators 1 and 2 Cooling air RWS_trolleybus_hybrid_B.doc Seite 8/20

9 5.2. Technical data of the Electrical combined storage unit Measures: Width 850, Height 950, Length 1800 [mm] Weight: ca 670 kg Power range of the electrical combined storage unit Li-Batterie UltraCap Number of Cells Energy content 17,3 kwh (0,686 kwh) 0,528 kwh Voltage V (0-624 V) V Charging current I max -80 A A Discharging current I max +200 A A Temperature charging 0 bis +40 C -20 bis +65 C Temperature discharging -30 bis +60 C -20 bis +65 C Power Range ±75 kw ±75 kw Useable energy ca. 10 kwh 0,2 bis 0,8 SOC 0,528 kwh Umin = 300V RWS_trolleybus_hybrid_B.doc Seite 9/20

10 5.3. Batterie Management System (BMS) Li-Battery Li-Battery Battery Monitoring Unit Monitoring Control Unit RWS_trolleybus_hybrid_B.doc Seite 10/20

11 6. Energy measurement and display with "ControlDesk" 6.1. energy from the catenary energy from the BoostCaps energy into the traction motor State of Charge Li-Battery FhG IVI Acceleration when catenary operation RWS_trolleybus_hybrid_B.doc Seite 11/20

12 6.2. energyr into the the catenary energy into the BoostCaps energy in the BoostCaps Energy recovery. Braking energy of energy the traction from the motor traction motor State of Charge Li-Battery State of Charge Li-Battery FhG IVI Brakes when catenary operation RWS_trolleybus_hybrid_B.doc Seite 12/20

13 6.3. energy from the BoostCaps Power reduction to 50 kw is activ energy into the traction motor energy from the Li-Battery FhG IVI Acceleration when emergency operation RWS_trolleybus_hybrid_B.doc Seite 13/20

14 6.4. energy into the BoostCaps Energy recovery Braking energy from the traction motor energy into the Li-Battery FhG IVI Brakes when emergency operation RWS_trolleybus_hybrid_B.doc Seite 14/20

15 7. Drive cycle 7.1. move to full throttle and stop (without BoostCap and 6 t payload) Input current Speed Torque RWS_trolleybus_hybrid_B.doc Seite 15/20

16 7.2. move to full throttle and stop (with BoostCap and 6 t payload) BoostCap Input current Speed Torque RWS_trolleybus_hybrid_B.doc Seite 16/20

17 7.3 Storage components at catenary operation Catenary operation Emergency operation BoostCap Boostcap Li-Batterie Voltage range 300 to 480 V 300 to 600 V 360 to 490 V Current range +/- 250A +/- 250 A / -200A Temperature range - 20 to + 65 C - 20 bis + 40 C DC/DC-Converter catenary + 75 kw 75 KW 75 kw Energy content usable 0,247 kwh 0,394 kwh max. 12 kwh RWS_trolleybus_hybrid_B.doc Seite 17/20

18 8. Evaluation of energy management 8.1. Evaluation of catenary operation - The concentration of trolley busses in the catenary system and the respective time of the day are essential for energy recovery. - Lowering the peak power of 400 A to about 300A - Reducing energy consumption by 7.3 % at 6 t payload by 9,4 % at unloaded operation With a usable storage capacity of kwh Average of 3.2 cycles / km (accelerate roll - brake) - This BoostCap memory is too small for a long mountain trip. - Alternatively the Li-battery could be included RWS_trolleybus_hybrid_B.doc Seite 18/20

19 8.2. Evaluation of emergency operation For emergency operation the power supply is permently reduced to about 40 kw in the Electronic drive/braking control unit (EFB, Vossloh Kiepe). This power supply reduction should be raised. Measuring results: Empty weight Payload of 6 t Operating distance 13,5 km 8,3 km Average speed 22,9 km/h 17,5 km/h Energy consumption 11,8 kwh 9,8 kwh RWS_trolleybus_hybrid_B.doc Seite 19/20

20 9. Offer of the company RWS The combined storage unit has been developed for the hybrid systems of vehicles used in Public Transportation such as trams, coaches and trolley-busses. It allows the recuperation of braking energy by means of BoostCaps and the traction without catenary on the basis of the energy off a Lithium Battery. Both of the storage batteries have a customized cell management system. Range of services rendered by the RWS Railway Service GmbH: - Preliminary design considering the energy and lay out design - Dimensioning of the energy storage unit and design of the case - Electronic control system and software for the energy management - Display of operating states and fault diagnosis - Cooling system, smoke detector, insulation monitoring - Installation and assembly of the electrical combined storage unit into the vehicle. The company of RWS offers the electrical combined storage unit as a complete package. Static commissioning took place in the test facilities of the Fraunhofer Institute of Transportation and Infrastructure Systems (IVI) in Dresden. The subsequent dynamic commissioning of the electrical combined storage unit has already been successfully completed in the trolley wire system of the Barnim Bus Company in Eberswalde. RWS_trolleybus_hybrid_B.doc Seite 20/20

TRAMS TROLLEY-BUSES SUBWAY

TRAMS TROLLEY-BUSES SUBWAY 9 FT-100-600 Traction Inverter for Asynchronous Drives 11 FT-105-600 Traction Inverter for Asynchronous Drives 13 FT-170-600 Traction Inverter for Asynchronous Drives 15 FT-300-600 Traction Inverter for

More information

Hybrid shunter locomotive

Hybrid shunter locomotive Hybrid shunter locomotive 1 Hervé GIRARD, Presenting Author, 2 Jolt Oostra, Coauthor, 3 Joerg Neubauer, Coauthor Alstom Transport, Paris, France 1 ; Alstom Transport, Ridderkerk, Netherlands 2 ; Alstom

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

Frequency Converter Fv

Frequency Converter Fv 2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)

More information

Analysis of fuel cell

Analysis of fuel cell Analysis of fuel cell commuter rail vehicles Stuart Hillmansen*1 1, D Meegahawatte1, C Roberts, P Jennings2, A McGordon2; 1University of Birmingham, United Kingdom, 2University of Warwick, United Kingdom

More information

Elektrofahrzeug mit Range Extender die Entwicklungsherausforderung Electric Vehicle with Range Extender. The developement challenge

Elektrofahrzeug mit Range Extender die Entwicklungsherausforderung Electric Vehicle with Range Extender. The developement challenge Elektrofahrzeug mit Range Extender die Entwicklungsherausforderung Electric Vehicle with Range Extender Dr. M. Korman AVL-List GmbH The developement challenge Stärkung regionaler Kooperationen in der Elektromobilität

More information

EFC 3600. Frequency converters

EFC 3600. Frequency converters 2 Bosch Rexroth AG Electric Drives and Controls Documentation Compact and complete: space saving side-by-side assembly, plug-in I/O terminals, with brake chopper and mains filter for ultra-simple installation

More information

Energy efficiency and fuel consumption of fuel cells powered test railway vehicle

Energy efficiency and fuel consumption of fuel cells powered test railway vehicle Energy efficiency and fuel consumption of fuel cells powered test railway vehicle K.Ogawa, T.Yamamoto, T.Yoneyama Railway Technical Research Institute, TOKYO, JAPAN 1. Abstract For the purpose of an environmental

More information

Fuel Cell solutions for maritime and harbour applications Proton Motor Fuel Cell GmbH. Sebastian Dirk Venice, 14th of June

Fuel Cell solutions for maritime and harbour applications Proton Motor Fuel Cell GmbH. Sebastian Dirk Venice, 14th of June Fuel Cell solutions for maritime and harbour applications Proton Motor Fuel Cell GmbH Sebastian Dirk Venice, 14th of June The Company Proton Motor Proton Motor Fuel Cell GmbH is a leading manufacturer

More information

How To Powertrain A Car With A Hybrid Powertrain

How To Powertrain A Car With A Hybrid Powertrain ELECTRIFICATION OF VEHICLE DRIVE TRAIN THE DIVERSITY OF ENGINEERING CHALLENGES A3PS Conference, Vienna Dr. Frank Beste AVL List GmbH 1 Motivation for Powertrain Electrification Global Megatrends: Urbanization

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module! Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8

More information

48V eco-hybrid Systems

48V eco-hybrid Systems 48V eco-hybrid Systems Jean-Luc MATE Vice President Continental Engineering Services France President Automotech cluster www.continental-corporation.com Division Naming European Conference on Nanoelectronics

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

EVBIKE LCD Display Control User Guide. EVBIKE LCD Display Control User Guide WWW.EVBIKE.CZ - 1 -

EVBIKE LCD Display Control User Guide. EVBIKE LCD Display Control User Guide WWW.EVBIKE.CZ - 1 - EVBIKE LCD Display Control User Guide WWW.EVBIKE.CZ - 1 - Table of Contents: 1) Description of the individual components and installation 2) Description of the measured quantities and user control display

More information

MPR-Systems. Mini Power Racks 1200 W - 8100 W

MPR-Systems. Mini Power Racks 1200 W - 8100 W LUCAS-BENNING World Class Power Solutions With compliments Helmut Singer Elektronik www.helmut-singer.de info@helmut-singer.de fon +49 241 155 315 fax +49 241 152 066 Feldchen 16-24 D-52070 Aachen Germany

More information

Contractors Guide Central Inverter System Installation

Contractors Guide Central Inverter System Installation Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.

More information

Technical requirements

Technical requirements Technical requirements of site preparation for TF-T1 Module Project Manager / / Head of technical department /K. Nikitin/ St.-Petersburg 2009 Contents 1. Technical specification of TF-T1 module 2. Appearance

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why

More information

Modern electrical propulsion systems for rolling stock

Modern electrical propulsion systems for rolling stock odern electrical propulsion systems for rolling stock Athen, January 2006 Andreas Fuchs TS GT DP Copyright Siemens AG 2005. All Rights Reserved. TS GT DP, Fuchs Folie odern electrical propulsion systems

More information

SUCCESS EPCOS Capacitors

SUCCESS EPCOS Capacitors SUCCESS EPCOS Inc. Capacitors Group April, 2012 EV / HV / E-Mobility Battery charger system & Inverter On Board and Off Board Assembly Trend: Wireless Charging DC/DC Converter Filtering DC Link E-Mobility

More information

*.ppt 11/2/2009 12:48 PM 1

*.ppt 11/2/2009 12:48 PM 1 Digital Compressor Controller *.ppt 11/2/2009 12:48 PM 1 Copeland Scroll Digital Controller Simple Controller That Enables OEM s To Use Digital Scrolls Relieves OEM From Developing Special Controllers

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Mild Hybrids. Virtual

Mild Hybrids. Virtual PAGE 20 CUSTOMERS The new 48-volt vehicle electrical system is opening up new possibilities for powerful, cost-efficient hybrid drives. This leads to new challenges for validating the installed power electronics.

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Technical data UNIBLOCK UBSF 180 625

Technical data UNIBLOCK UBSF 180 625 Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power

More information

Operating Manual UWAPS-TINY Series

Operating Manual UWAPS-TINY Series Operating Manual UWAPS-TINY Series Powecon Oy WWW.POWECON.FI 1/9 Table of content 1 Warranty...3 2 Safety information...3 3 Abbreviations and terminology...3 4 List of appendices...4 5 Introduction...4

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Vanner 80-kJ Bus Ultra Capacitor for Starting Assist and Dead Battery Start

Vanner 80-kJ Bus Ultra Capacitor for Starting Assist and Dead Battery Start Vanner 80-kJ Bus Ultra Capacitor for Starting Assist and Dead Battery Start 1. Introduction Regular vehicle starting system contains an engine, a starter motor, and an alternator (or a starter/alternator

More information

Introduction to Electronic Signals

Introduction to Electronic Signals Introduction to Electronic Signals Oscilloscope An oscilloscope displays voltage changes over time. Use an oscilloscope to view analog and digital signals when required during circuit diagnosis. Fig. 6-01

More information

Power Supply Systems. Performance guaranteed. Power Supply Systems single-voltage UIC-systems multi-voltage UIC-systems

Power Supply Systems. Performance guaranteed. Power Supply Systems single-voltage UIC-systems multi-voltage UIC-systems Power Supply Systems. Performance guaranteed. Power Supply Systems single-voltage UIC-systems multi-voltage UIC-systems Power Supply Components Battery Chargers Inverters and Converters Date: May 2011

More information

TEP 200WIR Series, 180 240 Watt

TEP 200WIR Series, 180 240 Watt TEP 200WIR Series, 180 240 Watt Features Chassis mount with screw terminal block Including EMI filter to meet EN 55022, class A Ultra wide 4:1 input voltage ranges 8.5 36, 16.5 75, 43 160 VDC EN 50155

More information

DC DC CONVERTER 1000W 100-400VDC Input / 12VDC Output

DC DC CONVERTER 1000W 100-400VDC Input / 12VDC Output DC DC CONVERTER 1000W 100-400VDC Input / 12VDC Output Code prod. : 30x57090.00 Feb, 11 th 2005 MES DEA s.a. - Service - Copying of this document and giving it to others and the use or communication of

More information

Kelly KBS-L Brushless Motor Controller User s Manual

Kelly KBS-L Brushless Motor Controller User s Manual Kelly KBS-L Brushless Motor Controller User s Manual Devices Supported: KBS24051L KBS24101L KBS24121L KBS36051L KBS36101L KBS48051L KBS48101L KBS48121L KBS72051L KBS72101L KBS72121L Rev.4.1 Jan. 2014 Chapter

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Volvo 7700 Hybrid. Getting there by Hybrid. Technology

Volvo 7700 Hybrid. Getting there by Hybrid. Technology Volvo 7700 Hybrid Getting there by Hybrid Technology the green challenge Authorities all over the world set strict environmental boundaries for public transports. Energy use, pollution and global warming

More information

DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB. Oil & Gas Energy Catalogue DC UPS RTB.e 50-1000 A 3 phase rectifier battery chargers voltage: 400 Vac, 3-phase, 50/60 Hz voltage: 24/48/110/220 Vdc RMB.e/RCB.e 50-100-150 A 1 and 3 phase compact rectifier

More information

Open Source 100kW Electric Vehicle Controller/Inverter

Open Source 100kW Electric Vehicle Controller/Inverter Open Source 100kW Electric Vehicle Controller/Inverter To be used with an AC Induction Motor Description By Tony Ahmann Abstract The Open Source 100kW Electric Vehicle Controller/Inverter acts as the bridge

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Product Specification

Product Specification Product Specification 07/2014 Product Middle install intelligent LCD Display Mode Abbreviation C965A Client Customer audit Supplier Tianjin APT Development Co., Ltd. Room 609, Hi-tech Building H, No.6

More information

hybrid fuel cell bus

hybrid fuel cell bus hybrid fuel cell bus PURE EMOTION PURE capacity The full passenger capacity of a standard diesel bus seats 34 standees 70 (7 passengers per sqm) total 104 Thanks to the three axles of the Van Hool A330

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

LIST OF CONTENTS STARTING DEVICES. Bull Starter 12V Bull Starter 12/24 V Genesis EP16 Memory Saver P 3 Professional Booster Cables for Car and Truck

LIST OF CONTENTS STARTING DEVICES. Bull Starter 12V Bull Starter 12/24 V Genesis EP16 Memory Saver P 3 Professional Booster Cables for Car and Truck LIST OF CONTENTS STARTING DEVICES Bull Starter 12V Bull Starter 12/24 V Genesis EP16 Memory Saver P 3 Professional Booster Cables for Car and Truck BULL STARTER 12 V The Banner booster for professionals!

More information

AD425S Automatic door operator

AD425S Automatic door operator EC8666 Statement Automatic Door Operator is a reliable and quiet door opening and closing device. This product is ideal for enabling access to areas for people with disabilities or simply for convenience

More information

HYBRID POWER SYSTEMS for TELECOM applications

HYBRID POWER SYSTEMS for TELECOM applications HYBRID POWER SYSTEMS HYBRID POWER SYSTEMS HYBRID POWER SYSTEM WITH AC GENSET PRAMAC has developed a new solution that allow coupling a traditional AC constant speed diesel genset with an energy storage

More information

Smoke exhaust systems

Smoke exhaust systems 1 Fire zone, e.g. hall 2 Smoke exhaust zone, separated by smoke curtains Natural and mechanical smoke extraction General information 3 Natural smoke and heat exhaust vent 4 Air inlet opening or wake max.

More information

Multi-Protocol decoder 76 200 with Load regulation

Multi-Protocol decoder 76 200 with Load regulation Multi-Protocol decoder 76 2 with Load regulation For locomotives with universal motors on digital layouts operating in the DCC and Motorola data format. Features 76 2 Load regulated multi-protocol decoder

More information

Hybrid System Overview

Hybrid System Overview 1 Hybrid System Overview January 31, 2004 2 Chevrolet Silverado / GMC Sierra Models: Extended Cab Short Box, 2WD & 4WD Engine: VORTEC 5.3 Liter V-8 Transmission: 4-speed auto transmission Power: 295 hp

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008 CAT AVR V2.3 Voltage regulator for generators March 2008 Instruction Manual Warnings WARNING The system should not be installed, operated, serviced or modified except by qualified personnel who understand

More information

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion Rectifiers Microprocessor controlled rectifier technology Fully adjustable float, boost and equalizing charge modes with V/I characteristic Advanced technology for phase control Verylowvoltage ripple and

More information

Servo drives. Compact converter IndraDrive Cs

Servo drives. Compact converter IndraDrive Cs Compact converter IndraDrive Cs 2 Bosch Rexroth AG Electric Drives and Controls Documentation Highly versatile, extremely compact drives Power range 100 W to 9 kw Multi-protocol-enabled, Ethernet-based

More information

Signature and ISX CM870 Electronics

Signature and ISX CM870 Electronics Signature and ISX CM870 Electronics Cummins West Training Center System Description General Information The Signature and ISX CM870 engine control system is an electronically operated fuel control system

More information

INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016. www.elipse-automation.eu

INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016. www.elipse-automation.eu INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016 Your partner in an automated industry Our combination of technical know-how, product responsibility and on-time deliveries guarantees you the best WHY CHOOSE

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

BB800 Off-Grid Solar System

BB800 Off-Grid Solar System BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry

More information

RX 60 Technical data.

RX 60 Technical data. RX 60 Technical data. Electric forklift trucks RX 60-40 RX 60-45 RX 60-50 Achieve more. RX 60 Technical Data. This specification sheet to VDI Guidelines 2198 only gives the technical figures for the standard

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

BATTERY MANAGEMENT THE HEART OF EFFICIENT BATTERIES BATTERY TECHNOLOGIES FOR ELECTRO 28 TH NOVEMBER 2013 MOBILITY AND SMART GRID PURPOSES

BATTERY MANAGEMENT THE HEART OF EFFICIENT BATTERIES BATTERY TECHNOLOGIES FOR ELECTRO 28 TH NOVEMBER 2013 MOBILITY AND SMART GRID PURPOSES BATTERY MANAGEMENT THE HEART OF EFFICIENT BATTERIES BATTERY TECHNOLOGIES FOR ELECTRO MOBILITY AND SMART GRID PURPOSES 28 TH NOVEMBER 2013 Presentation Agenda 1. Introduction to LiTHIUM BALANCE 2. Battery

More information

Electric forward facing seat/ Three-in-one forklift EFX 410/413.

Electric forward facing seat/ Three-in-one forklift EFX 410/413. 1344.GB.1.0.10.r.r.s Technical modifications reserved. Electric forward facing seat/ Three-in-one forklift EFX 410/413. 1000 and 120 kg capacity. Jungheinrich Plants, Sales and Services Europe ISO 9001/

More information

Electronic Power Control

Electronic Power Control Service. Self-Study Programme 210 Electronic Power Control Design and Function With the Electronic Power Control system, the throttle valve is actuated only by an electric motor. This eliminates the need

More information

Charge Regulator SCR 12 Marine

Charge Regulator SCR 12 Marine Charge Regulator SCR 12 Marine Manual Many thanks for purchasing a superwind product. The SCR 12 Marine is a charge regulator of highest quality and will perfectly and reliably charge your batteries for

More information

MOVING YOU FURTHER HYUNDAI HEAVY INDUSTRIES

MOVING YOU FURTHER HYUNDAI HEAVY INDUSTRIES Electric Counterbalance Trucks MOVING YOU FURTHER HYUNDAI HEAVY INDUSTRIES Your satisfaction is our priority! Hyundai introduces a new line of 9-series battery forklift trucks. The newly designed 4 wheel

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

32VFD Variable Frequency Drives for Centrifugal Chillers

32VFD Variable Frequency Drives for Centrifugal Chillers 32VFD 32VFD Variable Frequency Drives for Centrifugal Chillers ENERGY-SAVING CONTROL FOR CENTRIFUGAL CHILLERS Reduce energy consumption in your existing centrifugal chiller Your chiller was specified to

More information

Contents. TRIP & time clearance 11 Backlight 12 Wheel size 12

Contents. TRIP & time clearance 11 Backlight 12 Wheel size 12 Manual C963 Contents Preface 3 Appearance & size 4 Material & color 4 Function & button 5 Function 5 Display 5 Button 6 Attentions 6 Installation 7 Operation 7 ON/OFF 7 Interface 7 Assist walking 8 Backlight

More information

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0 Data sheet GIOD.1 Input/output module with CAN bus ERP no.: 5204183 www.guentner.de Page 2 / 10 Contents 1 GIOD.1... 3 1.1 Functional description...3 1.2 Connections... 5 1.3 Electrical properties of...

More information

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps 0.9 Boost Driver for White LEDs in Solar Lamps The is a single cell step-up converter for white LEDs operating from a single rechargeable cell of 1.2 supply voltage down to less than 0.9. An adjustable

More information

Preface. The Schachner e-kit has been developed in Austria especially for mountain cyclists and it proved very well.

Preface. The Schachner e-kit has been developed in Austria especially for mountain cyclists and it proved very well. Stand April 2013 1 Preface Dear client! We want to congratulate on your acquisition of a Schachner central motor electric kit. We are glad to inform you about operation, maintenance and care of our e-kits

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

12V/15.0A SLA Battery Charger Specification

12V/15.0A SLA Battery Charger Specification Via Garofoli 309, 37057 San Giovanni Lupatoto, Verona (IT) PI/CF: 01915010233 - mail@ipesrl.com Tel. +39 0458751092 Fax +39 0458751093 12V/15.0A SLA Battery Charger Specification 1. General 2. Main product

More information

47000 SERIES - ELECTRONIC TRANSFORMERS

47000 SERIES - ELECTRONIC TRANSFORMERS 7000 SERIES - ELECTRONIC TRANSFORMERS MYRRA encapsulated electronic transformers are Switched Mode Power Supplies based on Flyback topology. They constitute an interesting alternative to the traditional

More information

LK Electric Boiler - 4,5

LK Electric Boiler - 4,5 LK Electric Boiler -, Design LK Electric Boiler, kw is a wall-mounted electric boiler, intended primarily for low-temperature heating systems, e.g. under floor heating. LK Electric Boiler, kw is delivered

More information

Sustainable mobility: the Italian technological challenge

Sustainable mobility: the Italian technological challenge Sustainable mobility: the Italian technological challenge an innovative paradigm for a new vehicles' generation ANFIA-ANIE ANIE WORKSHOP Hannover Messe 2010, April 19th Ing. Pier Luigi Farina DUCATI energia:

More information

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com.

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com. IS26 Concrete Spraying Machine IS26 Concrete Spraying Machine TECHNICAL SPECIFICATIONS Manipulator Max. vertical spraying reach : Max. horizontal spraying reach : Working lights : Spraying Head Rotation

More information

Manual. Solar Fountain Mobile Phone Charger

Manual. Solar Fountain Mobile Phone Charger EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.

More information

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS D R I V E S Y S T E M S PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS The vision of Iskra Avtoelektrika is to be: One of the world's leading manufacturers of electric motors and controllers for

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

LITHIUM-ION ENERGY MODULES HEM & HPM SERIES

LITHIUM-ION ENERGY MODULES HEM & HPM SERIES High Efficiency by leading edge Lithium-Ion technology Maximum energy density by compact design Easy installation by central connector Highest power output by integrated energy management system Long lifetime

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

DCS Input/Output Relay Card Series

DCS Input/Output Relay Card Series Input/Output Relay Card Series I/O RELAY CARD (with loopback test function) 8N The 8N series I/O Relay Cards easily and quickly standardize and facilitate installation of the relay board. Loopback test

More information

picking or transportation capabilities.

picking or transportation capabilities. Latch onto your full low level order picking or transportation capabilities. The new Hyster T5Z AC and T7Z AC Tow Tractors provide you the towing capacities to meet your needs. The 3-phase AC induction

More information

MITRAC 500. Driven by Reliability. Propulsion & Controls

MITRAC 500. Driven by Reliability. Propulsion & Controls MITRAC 500 Driven by Reliability Propulsion & Controls MITRAC Low Power exceeding your expectations The BOMBARDIER* MITRAC* 500 product portfolio is a family of propulsion systems for light rail vehicles

More information

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors ABLOY DOOR AUTOMATICS Easy access for all types of swing doors Automatic door operators bring additional convenience in situations where the doors opening manually would be inconvenient or laborious. Recommended

More information

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits: Variable Frequency Drives (or VFDs) are becoming almost standard part of aquatics equipment room packages. Most VFDs are fairly simple to install and operate however, they are quite complex with respect

More information

Technical specifications. Containerized data centre NTR CDC 40f+

Technical specifications. Containerized data centre NTR CDC 40f+ Technical specifications Containerized data centre NTR CDC 40f+ CONTENT 1 THE PURPOSE OF CDC... 3 2 BASIC PROPERTIES... 4 2.1 EXTERNAL DIMENSIONS... 4 2.2 INSTALLATION REQIREMENTS... 4 2.3 ELECTRICAL CONNECTION

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

ELECTRIC BUS DEVELOPMENT in the Czech Republic and Slovakia. Jan SPOUSTA, CDV (Transport Research Centre CZ) jan.spousta@cdv.cz

ELECTRIC BUS DEVELOPMENT in the Czech Republic and Slovakia. Jan SPOUSTA, CDV (Transport Research Centre CZ) jan.spousta@cdv.cz ELECTRIC BUS DEVELOPMENT in the Czech Republic and Slovakia Jan SPOUSTA, CDV (Transport Research Centre CZ) jan.spousta@cdv.cz TROLLEY EU Project Final Conference, Szeged, January 2013 ELECTRIC BUS DEVELOPMENT

More information

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10 ABB ABB Schweiz AG Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205 09.04.2014 Page: 8201 Schaffhausen 1 / 10 Please use also the assembly instruction S800-RSU-H Remote

More information

HyPM Fuel Cell Power Modules

HyPM Fuel Cell Power Modules HyPM Fuel Cell Power Modules HyPM XR Fuel Cell Power Module for stationary and backup power applications HyPM HD Fuel Cell Power Module for mobility applications Purpose-built to deliver the best in performance

More information

GST301. (Single Protection Zone) Operation Manual

GST301. (Single Protection Zone) Operation Manual GST301 Gas Extinguishing Control Panel (Single Protection Zone) Operation Manual 2 of 19 CONTENTS 1 OVERVIEW... 4 2 TECHNICAL DATA... 4 3 STRUCTURES... 5 3.1 FRONT SURFACE DESCRIPTION... 5 3.1.1 Indicators...

More information

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere Application GSM-R 900 coverage enhancement Outdoor : Cell extension Indoor : Tunnels and confined areas Key Features Medium & High Power Band- & Channel- Selective Digital Smart Filter Outdoor IP65 cabinet

More information

SINAMICS G130. Braking Module / braking resistor. Operating Instructions 05/2010 SINAMICS

SINAMICS G130. Braking Module / braking resistor. Operating Instructions 05/2010 SINAMICS SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Operating Instructions Mechanical installation 3 Connection 4 Maintenance and servicing 5

More information