- 9 years ago
- Views:
Transcription
1 Liquid Waveguide Capillary Cell LPC-100CM, LPC-250CM and LPC-500CM Installation and Operation Manual Document Number Offices: Ocean Optics, Inc. 830 Douglas Ave., Dunedin, FL, USA Phone Fax :30 a.m. 6 p.m. EST [email protected] (General sales inquiries) [email protected] (Questions about orders) [email protected] (Technical support) A
2 Additional Offices: Ocean Optics Asia 666 Gubei Road, Kirin Tower, Suite 601B, Changning District, Shanghai, PRC Phone Fax Ocean Optics EMEA Sales and Support Center Geograaf 24, 6921 EW DUIVEN, The Netherlands Phone 31-(0) Fax 31-(0) Regional Headquarters Maybachstrasse Ostfildern Phone Fax Copyright 2004 Ocean Optics, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from Ocean Optics, Inc. This manual is sold as part of an order and subject to the condition that it shall not, by way of trade or otherwise, be lent, re-sold, hired out or otherwise circulated without the prior consent of Ocean Optics, Inc. in any form of binding or cover other than that in which it is published. Trademarks Microsoft, Windows, Windows 95, Windows 98, Windows Me, Windows NT, Windows 2000, Windows XP and Excel are either registered trademarks or trademarks of Microsoft Corporation. Limit of Liability Every effort has been made to make this manual as complete and as accurate as possible, but no warranty or fitness is implied. The information provided is on an as is basis. Ocean Optics, Inc. shall have neither liability nor responsibility to any person or entity with respect to any loss or damages arising from the information contained in this manual.
3 Important Safety Notices 1. Do NOT use perfluorinated solvents with the LWCC because the amorphous fluoropolymer tubing is soluble in these chemicals. 2. Do NOT exceed a fluid pressure of 45 PSI. 3. LWCC will function with most liquids (one exception: perfluorinated solvents) having a refractive index > Ensure that the plumbing fittings through the front panel are tight and free of leaks. 5. Minimize the injection of bubbles into the LWCC since they will cause erratic results. Continuous pumping will typically flush the bubbles through the system. 6. At the end of each experimental session, flush the system with solvent and then pump dry. Avoid leaving fluid in the LWCC for extended periods of time. Ocean Optics Waveguide Cleaning Kit (LPC-CLEANKIT) is recommended for cleaning the LWCC between uses and sample runs. 7. Opening the chassis invalidates the warranty. Components inside are very fragile and are not user-serviceable. Contact Ocean Optics immediately if you have trouble with the instrument. 8. WARNING: THIS EQUIPMENT IS NOT DESIGNED OR INTENDED FOR USE ON HUMANS. Warranty WPI (World Precision Instruments, Inc.) warrants to the original purchaser that this equipment, including its components and parts, shall be free from defects in material and workmanship for a period of one year* from the date of receipt. WPI s obligation under this warranty shall be limited to repair or replacement, at WPI s option, of the equipment or defective components or parts upon receipt thereof f.o.b. WPI, Sarasota, Florida U.S.A. Return of a repaired instrument shall be f.o.b. Sarasota. The above warranty is contingent upon normal usage and does not cover products which have been modified without WPI s approval or which have been subjected to unusual physical or electrical stress or on which the original identification marks have been removed or altered. The above warranty will not apply if adjustment, repair or parts replacement is required because of accident, neglect, misuse, failure of electric power, air conditioning, humidity control, or causes other than normal and ordinary usage. To the extent that any of its equipment is furnished by a manufacturer other than WPI, the foregoing warranty shall be applicable only to the extent of the warranty furnished by such other manufacturer. This warranty will not apply to appearance terms, such as knobs, handles, dials or the like. WPI makes no warranty of any kind, express or implied or statutory, including without limitation any warranties of merchant ability and/or fitness for a particular purpose. WPI shall not be liable for any damages, whether direct, indirect, special or consequential arising from a failure of this product to operate in the manner desired by the user. WPI shall not be liable for any damage to data or property that may be caused directly or indirectly by use of this product. Electrodes, batteries and other consumable parts are warranted for 30 days only from the date on which the customer receives these items A
4 Important Safety Notices Claims and Returns Inspect all shipments upon receipt. Missing cartons or obvious damage to cartons should be noted on the delivery receipt before signing. Concealed loss or damage should be reported at once to the carrier and an inspection requested. All claims for shortage or damage must be made within 10 days after receipt of shipment. Claims for lost shipments must be made within 30 days of invoice or other notification of shipment. Please save damaged or pilfered cartons until claim settles. In some instances, photographic documentation may be required. Some items are time sensitive; WPI assumes no extended warranty or any liability for use beyond the date specified on the container. WPI cannot be held responsible for items damaged in shipment en route to us. Please enclose merchandise in its original shipping container to avoid damage from handling. We recommend that you insure merchandise when shipping. The customer is responsible for paying shipping expenses including adequate insurance on all items returned. Do not return any goods to WPI without obtaining prior approval and instructions (RMA#) from our returns department. Goods returned unauthorized or by collect freight may be refused. The RMA# must be clearly displayed on the outside of the box, or the package will not be accepted. Please contact the RMA department for a request form. Goods returned for repair must be reasonably clean and free of hazardous materials. A handling fee is charged for goods returned for exchange or credit. This fee may add up to 25% of the sale price depending on the condition of the item. Goods ordered in error are also subject to the handling fee. Equipment built as a special order cannot be returned. Always refer to the RMA# when contacting WPI to obtain a status of your returned item. For any other issues regarding a claim or return, please contact the RMA department: World Precision Instruments, Inc. International Trade Center 175 Sarasota Center Boulevard Sarasota FL USA Tel: Fax: [email protected] Internet: B
5 Table of Contents Important Safety Notices...A Warranty... A Claims and Returns... B About This Manual...iii Document Purpose and Intended Audience... iii Document Summary... iii Product-Related Documentation... iii Upgrades...iii Chapter 1: Introduction...1 Overview...1 LWCC Properties...2 Effective Pathlength and Linearity... 2 Pressure and Flow Rate... 3 Mechanical Properties... 3 Light Throughput of Fiber Optic Cables... 3 Chapter 2: Setup...5 Overview...5 Unpacking the LWCC...5 Contents... 5 Other Accessories Not Provided... 5 Connections...6 Plumbing Connections... 6 Tightening the Plumbing Connections... 7 Fiber Connections... 7 Assessing if the LWCC is Free of Particles i
6 Table of Contents Chapter 3: Operation...11 Overview...11 Measuring in a Continuous Flow...11 Measuring Discrete Samples...12 Chapter 4: Maintenance...13 Overview...13 Tips to Avoid Contamination...13 Cleaning...14 Instrument Storage...15 Troubleshooting...15 Appendix A: Specifications...17 Index...19 ii
7 About This Manual Document Purpose and Intended Audience This document provides the LWCC user with instructions for setting up, running and maintaining the LWCC device. Document Summary Chapter Chapter 1: Introduction Chapter 2: Setup Chapter 3: Operation Chapter 4: Maintenance Appendix A: Specifications Description Contains descriptive information about the LWCC and its properties. Contains a list of package contents and unpacking instructions. Also provides instructions for making fiber and plumbing connections. Contains instructions for measuring a continuous flow and discrete samples with the LWCC. Provides tips for avoiding contamination, as well as cleaning instructions and storage recommendations. Also contains a troubleshooting table. Provides technical specifications for the LWCC. Product-Related Documentation You can access documentation for Ocean Optics products by visiting our website at Select Technical Operating Instructions, then choose the appropriate document from the available drop-down lists. Or, use the Search by Model Number field at the bottom of the web page. Engineering-level documentation is located on our website at Technical Engineering Docs. Upgrades Occasionally, you may find that you need Ocean Optics to make a change or an upgrade to your system. To facilitate these changes, you must first contact Customer Support and obtain a Return Merchandise Authorization (RMA) number. Please contact Ocean Optics for specific instructions when returning a product iii
8 About This Manual iv
9 Chapter 1 Introduction Overview The Liquid Waveguide Capillary Cell (LWCC) from Ocean Optics features optical sample cells that combine an increased optical pathlength ( cm) with small sample volumes ( µl) with fiber optic capabilities. The LWCC connects with optical fibers to Ocean Optics high-sensitivity fiber optic spectrometers and compact light sources via SMA terminations for simple, efficient measurement of low-volume or low-concentration (ppb-ppt) aqueous samples. The LWCC functions with most liquids (with the exception of perfluorinated solvents) having a refractive index >1.30. Similar to optical fibers, light is confined within the (liquid) core of an LWCC by total internal reflection at the core/wall interface. Ultra-sensitive absorbance measurements can be performed in the ultraviolet (UV), visible (VIS) and near-infrared (NIR) ranges to detect low sample concentrations in a laboratory or process control environment. According to Beer s Law, the absorbance signal is proportional to chemical concentration and light path length. Compared with a standard 1-cm cell, a 1-mAU signal is enhanced fifty-fold with a 50-cm cell to 50 mau using the LWCC s patented aqueous waveguide technology. The LWCC is available in 1-meter (LPC-100CM), 2-meter (LPC-250CM) and 5-meter (LPC-500CM) pathlengths for absorbance measurements
10 1: Introduction LWCC Properties Similar to optical fibers, light is confined within the (liquid) core of an LWCC by total internal reflection at the core/wall interface. Optical fibers are then used to transport light to and from the sensor cell. Designed for use with fiber optics, both LWCCs require only small sample volumes and have a high optical throughput. The LWCC is made from fused silica tubing with an outer coating of a low refractive index polymer. The core liquid is contained by the synthetic silica tube coated with the low refractive index cladding material. Placing the refractive surface outside the silica protects it from undesirable effects of the liquid. In addition, the fused silica wall is impermeable to gases. Lateral Section of LWCC Effective Pathlength and Linearity Effective pathlength and linearity have been extensively studied with the LWCC. Effective pathlength is defined as the equivalent pathlength of the cell, assuming the LWCC strictly follows Beer s law. Although there have been several reports in the literature in which calculation of effective pathlength has been performed, the theoretical basis by which to calculate the effective pathlength of the LWCC has not yet been established. It is, therefore, currently determined experimentally. The effective optical pathlength was determined to be slightly shorter than the physical pathlength (0.94± 0.01 times of its physical pathlength), dependent on the LWCC s inner diameter and wall thickness. This is caused by the fact that light is partially traveling in the fused silica wall of the LWCC. By Beer s Law, the absorption of a liquid sample in the LWCC bears a linear relationship to the concentration of an analyte. The LWCCs were extensively tested and proved to be linear over a range of 0.01 to 2.0 AU (limited only by noise and stray light from the measuring spectrophotometer). A detailed analysis of the effective pathlength and linearity of the LWCCs has been published (Belz et al., 1999).* * Mathias Belz, Peter Dress, Aleksandr Sukhitskiy and Suyi Liu, Linearity and effective optical pathlength of liquid waveguide capillary cells, Part of the SPIE Conference on Internal Standardization and Calibration Architectures for Chemical Sensors, Boston, Massachusetts, September 1999, SPIE Vol. 3856,
11 Pressure and Flow Rate 1: Setup The applied pressure and fluid flow rate through the LWCC obeys the Hagen-Poiseuille relationship. Flow is proportional to pressure and to the fourth power of the diameter of the fluid capillary, as well as reciprocal to the length of the capillary and fluid viscosity. A one-meter length of 550 µm ID waveguide requires approximately 1.5 PSI for water flow of 1 ml/min. Mechanical Properties Maximum hydrostatic pressure that the LWCC can withstand has not yet been determined. It has been operated at 100 to 200 PSI without observed malfunction (a silica capillary with a similar structure has been reported to withstand pressures of at least 2000 PSI). Light Throughput of Fiber Optic Cables The graph below compare three different fiber optic cables (400μm, 500μm and 600μm) used with the LWCC. The 500 and 600μm fibers are recommended to obtain maximum light throughput on the LWCC. While the 400μm fibers are compatible with an LWCC, you can expect an approximate 50% decrease in light throughput
12 1: Introduction
13 Chapter 2 Setup Overview Setting up your LWCC involves unpacking the device and making fiber and plumbing connections. Unpacking the LWCC Upon receipt of this instrument, make a thorough inspection of the contents and check for possible damage. Note any missing cartons or obvious damage to cartons on the delivery receipt before signing. Report concealed loss or damage at once to the carrier and request an inspection (see Claims and Returns for information on returns). Call Ocean Optics if any parts are missing. Contents Your LWCC package should contain the following: LWCC unit Luer-fitted PEEK connectors with caps (package of 2) Quality Control document Contains the effective optical pathlength of the cell for this LWCC unit Other Accessories Not Provided The following accessories for your LWCC are required, but must be ordered separately: 500 or 600 µm Fiber optic cables (2) Detection system including either a spectrophotometer, or a spectrometer and a light source In addition, an optional Waveguide Cleaning Kit (LPC-CLEANKIT) is available from Ocean Optics. This kit is recommended for cleaning the LWCC between uses and sample runs. Visit our website at for a complete list of Ocean Optics products
14 2: Setup Connections The following connections must be made to use your LWCC: Plumbing (Liquid Port) Connections Fiber Connections Plumbing Connections On the front panel, there are two plumbing feed-through (liquid) ports labeled SAMPLE IN and SAMPLE OUT. It does not matter which one is used for the plumbing input or the plumbing output. However, if an inline filter is to be installed, connect it on the input side of the liquid flow path. For experimental consistency, once you have assigned which fitting will be the plumbing input and which one will be the plumbing output, try not to switch the plumbing configuration. Install the luer-fitted connectors to the ports. These fittings can be removed if the LWCC is to be connected to a fluid injection analysis system or a liquid chromatography column. Luer fittings may be replaced with other 1/16 inch (1.64 mm) OD tubing. Loosen the small nut at the base of the luer fitting, remove the fitting, insert new tubing and tighten the nut. If a Sample Injector Kit is to be used, it will take the place of the SAMPLE IN connector. The tubing goes over the plumbing fittings, which are standard ¼-28 threads. The tubing should fit snugly over the fittings and be free of leaks. Procedure 1. Attach one end of the tubing to your pump. The pump used must not pump the solution so fast that the fluid pressure exceeds 45 PSI. Note Remember to always turn off the pump in-between taking a reference and taking sample measurements. 2. Make sure you have a proper waste receptacle for the other end of the tubing
15 2: Setup Example LWCC Experimental Setup Tightening the Plumbing Connections The plumbing connections inside the LWCC are standard industry fittings. No maintenance is required. However, if leaks develop, the plumbing connections need to be tightened. Procedure To tighten the plumbing connections, 1. Remove the back panel. 2. Carefully slide off the top cover, being careful not to damage or pinch the tubing or fiber. 3. Hand-tighten the fittings and reassemble the cover and back panel. Fiber Connections Caution Unlike electric cables, fiber optic cables are fragile as they contain glass and are subject to breakage. Avoid sharp bends in the cables and protect them from impact or permanent damage can result. The light source and detector connect to the LWCC via two SMA-terminated fiber optic patch assemblies with a core diameter of 500 or 600 µm. For convenience only, each LWCC has the fiber optic connections marked as LIGHT IN and LIGHT OUT. The fiber optic connections are interchangeable in that either connector can be used to connect to the light source or to the spectrometer. Use these fiber optic connections to connect the LWCC to a light source and spectrometer (detector) module of your spectrophotometer system
16 2: Setup The fiber inside the LWCC has a core diameter of 500 μm. Procedure To connect the optical fibers, 1. Attach one end of an illumination fiber to a port on the LWCC. 2. Attach the other end of the fiber to your light source. 3. Attach one end of a read fiber to the second port on the LWCC. 4. Attach the other end of the fiber to your spectrometer. Assessing if the LWCC is Free of Particles Fluids need to be relatively particle-free. Particles larger than 20 m can be trapped inside the tubing and can then block or scatter a significant amount of light. Procedure To rid the LWCC of particles, follow these steps: 1. Pump the sample fluid through the LWCC
17 2. While in Scope Mode, save a dark spectrum with the light source off and a reference spectrum with the light source on. 2: Setup 3. Continue to pump the sample fluid and switch to the Absorbance Mode. Ideally, you should see a spectrally flat line (see Example Spectra below). Particle effects manifest themselves as an exponentially decreasing curve from shorter to longer wavelengths. The length of time that you pump the sample and the magnitude of the absorbance peak depend upon the time required and the minimum detectable absorbance value for your specific analyses. Prefiltering of the sample may be required to eliminate this exponentially decreasing absorbance spectrum if it is significant to your analyses. The following sample fluorescence spectra of quinine sulfate solution were obtained with an S2000 Fiber Optic Spectrometer (100 m slit, L2 Detector Collection Lens) and 1-meter LWCC with built-in 365-nm excitation source. The integration period was 500 milliseconds. Intensity was linear with concentration. The lowest detectable concentration of the sample was ~0.5 ppb. Example Spectra
18 2: Setup
19 Chapter 3 Operation Overview Using your LWCC system you can measure liquids In a continuous flow, or Using discrete samples Caution Materials exposed to fluid in the LWCC are CTFE, PEEK and fused silica. Any chemical that could harm these substances should not be used in the LWCC. For example, hydrofluoride (HF) dissolves silica, and PEEK can be damaged by concentrated sulfuric and nitric acids (40% w/w or greater). Keeping the LWCC clean is essential for a stable result. See Cleaning in Chapter 4: Maintenance. Measuring in a Continuous Flow Procedure 1. To help prevent clogging the ports, filter all samples using a 0.2µm vacuum filtration disc before injection into the LWCC. 2. Connect the LWCC to a light source and a detector with fiber optic cables. 3. Clean the LWCC using the standard cleaning procedure described in Chapter 4: Maintenance. 4. Connect the liquid source to the LWCC system. The standard Luer fitting at the LWCC input and output can be replaced with 1/16-inch (1.64 mm) tubing if necessary. A pressure of approx PSI is necessary to run liquid through the LWCC
20 3: Operation 5. Flush the LWCC with de-ionized water or experimental buffer solution using a pump or a syringe at a rate of 1mL/minute and observe the light intensity or absorbance baseline on the detector. Continue flushing until the signal is stable. (See Troubleshooting in Chapter 4: Maintenance if the signal does not stabilize appropriately.) Measuring Discrete Samples Discrete samples can be measured with the LWCC by introducing the sample with a syringe. Sample volumes approximately times the cell volume are necessary to fill the LWCC. When injecting a sample or reference solution, apply consistent hand pressure to the syringe. Small variations in baseline levels may result from using this method. Procedure 1. Using fiber optic cables, connect the LWCC to a light source and a detector. 2. Clean the LWCC using the standard cleaning procedure described in Chapter 4: Maintenance. 3. Flush the LWCC with de-ionized water or experimental buffer solution using a syringe and observe the light intensity or absorbance baseline on the detector until the signal is stable. 4. Introduce the sample slowly into the LWCC with a syringe using steady pressure to avoid generating air bubbles
21 Chapter 4 Maintenance Overview Thorough and consistent cleaning routines are essential for maintaining the instrument and ensuring optimal operation. Tips to Avoid Contamination The following information about contamination has been collected during the development and testing of the LWCC: Most syringe filters contain some contaminants that absorb UV (probably the plastic mold release agent). The first few milliliters of solution coming from a new filter will have some absorption in the UV range due to the mold release agent. The first two loads of solution from most new plastic syringes often have some contamination that absorbs UV. In addition, when plastic syringes are used to transfer organic solvents, the rubbery gasket material in the plunger absorbs some of the chemical. If the syringe is later used to transfer aqueous solution, the chemical will slowly leach out. Since most organic solvents have an absorbance in the UV range, the liquid initially released from the syringe might be found to have a different spectrum than the last of the liquid in the syringe, the latter having been contaminated by the chemical in the plunger. Some commonly used organic solvents with relatively low UV absorption that are suitable for UV detection in conventional spectrometers might not be problem-free when used in the LWCC. A beaker of freshly filtered water sitting overnight in open air will probably have an increased absorbance in the UV range because of dust from the air or growth of microorganisms. Some plastic tubing release a substance that absorbs UV. In lab tests, silicone tubing used in a peristaltic pump constantly released a contaminant even after a week of washing. A bubble in the LWCC will result in unstable readings. Additional liquid circulating through the device will usually push the bubble out. If the bubble doesn t clear easily, try introducing a larger bubble followed by liquid. This will usually pick up a small bubble that may cling and cause problems
22 4: Maintenance Avoid introducing particulate matter into the LWCC. If they are trapped in the LWCC, particles can scatter light and may cause unstable spectrometer readings. The LWCC contains two potential bottlenecks at the fiber-capillary interface. For the 550 µm ID waveguide, the bottlenecks are 75 µm-wide ring gaps. If a particle larger than 60 µm is forced into the waveguide and trapped there, it can take a lot of effort to remove it. Due to the diverse applications of LWCC, no in-line filter can be installed which will fit all users needs. It is imperative, therefore, that a proper in-line filter be added to the LWCC if the solution contains large particles. When the LWCC is directly connected to a chromatography column, a filter might not be necessary. Cleaning Before and after each usage of the LWCC, it is recommended that cleaning be performed. A Waveguide Cleaning Kit made especially for the LWCC is available from Ocean Optics (LPC-CLEANKIT). Procedure To clean your LWCC, use the following procedure: 1. Connect exit tubing (silicon or equivalent) from the OUTFLOW port of the LWCC to a waste container. 2. Rinse the cell thoroughly using Ultra Pure water. 3. Obtain a new reference intensity and take a baseline absorbance reading. 4. Fill a 1 cc syringe with Cleaning Solution 1 and inject it into the LWCC s INFLOW port via the Luer fitting adapters provided with your LWCC. 5. Fill a 1 cc glass-type syringe with Methanol Solution 2 and inject it into the INFLOW port of the LWCC. 6. Fill a 1 cc syringe with HCl Solution 3 and inject it into the INFLOW port of the LWCC. 7. Flush out cleaning solutions with distilled Ultra Pure, reverse osmosis, or equivalent quality water and take an absorbance reading. 8. Repeat these cleaning cycles until a stable absorbance signal can be obtained
23 4: Maintenance Instrument Storage Caution Do not partially dry the LWCC and leave it open to the air. Oxygen in the air may facilitate the growth of microorganisms inside the device. To store the instrument, clean the LWCC and then fill it with an 80/20 solution of distilled water/methyl alcohol. Seal the INFLOW and OUTFLOW ports using either the caps provided or an alternative. Troubleshooting The LWCC is a highly sensitive device, and it is extremely important to keep it clean. This is especially important when working in the ultraviolet range, where unexpected results can often be produced by contamination of the experimental solution. The high sensitivity of the LWCC may create some problems that can be easily overcome with care and forethought. Therefore, you may need to develop new skills in handling both the equipment and the samples being examined. Typical Contamination Effect Possible Cause(s) Suggested Solution(s) Transmission in both UV and visible ranges becomes low or very unstable. Transmission in the UV range is low. Transmission in the visible range is OK and stable. Transmission below 250 nm is low. Transmission in the visible range is OK and stable. A contamination layer (such as biofilm) is sticking to the LWCC wall. Or, a particle is trapped in the LWCC. 1. Optic fiber and silica tubing are coated by a layer of metal corrosion. 2. Optic fiber and silica tubing are coated by a layer of organics. Contamination of fiber optic cable end-faces with a metal film generated during repeated connection attempts. Flush the cell for 30 seconds each with each of the 3 cleaning solvents contained in the Waveguide Cleaning Kit. OR Prepare a 5% surfectant using Ultrasonic cleaning solution, followed by HPLC-grade Methanol and HPLC-grade 2N HCl solution. 1. Flush with 1 N HCl. 2. Flush with an organic solvent, such as acetonitrile. Wipe all fiber optic endfaces and fiber connections (on front of the LWCC) using a fiber optic foam swab dipped in methyl alcohol. Use of cotton swabs (Q-Tips) is not recommended
24 4: Maintenance
25 Appendix A Specifications Specification Waveguide material Optical pathlength Value Fused silica tubing coated with a low refractive index polymer 50, 100, 250, 500 cm Inner diameter 550 µm Internal volume ~ µl Sample inlet/outlet compression fitting 1/16 in., 1/32 in. Fiber core diameter 500 µm Maximum temperature 160ºC Gas permeability of cell Minimum pressures Maximum pressure Solvent resistance Shipping weight Path lengths None PSI 100 PSI Most organic and inorganic solvents 3 lbs. (1.36 kg) 1-meter, 2-meter, 5-meter (standard); custom lengths also available Tubing Teflon Amorphous Fluoropolymer 2400 Refractive index 1.29 ~560 µm inner diameter, ~800 µm outer diameter
26 A: Specifications Specification Value Internal volume µl Chemical resistance Recommended optical fibers for coupling to spectrometers and light sources Plumbing fittings Tubing can be altered by perfluorinated solvents, FREON 113, and Perclene 500 µm Standard ¼ in. x 28 chromatography fittings
27 Index A accessories, 5 assessment of particles, 8 C claims, B cleaning, 14 connection, 6 fiber, 7 plumbing, 6 contamination, 13 document audience, iii purpose, iii summary, iii example setup, 7 spectra, 9 fiber connection, 7 fiber optic cables light throughput, 3 flow rate, 3 light throughput, 3 linearity, 2 D E F L P package contents, 5 particle assessment, 8 pathlength, 2 plumbing connection, 6 tightening, 7 pressure, 3 product-related documentation, iii properties, 2 PSI, 3 R returns, B setup, 5 specifications, 17 storage, 15 S T tightening plumbing connections, 7 troubleshooting, 15 U unpacking, 5 upgrades, iii warranty, A W
28 Index
Installation and Operation Manual Document Number 000-vivo-110-02-201208
Installation and Operation Manual Document Number 000-vivo-110-02-201208 Offices: Ocean Optics, Inc. World Headquarters 830 Douglas Ave., Dunedin, FL, USA 34698 Phone 727.733.2447 Fax 727.733.3962 8 a.m.
Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
el-720 Carbon Dioxide Gas Leak Detector User s Guide
el-720 Carbon Dioxide Gas Leak Detector User s Guide Congratulations on the purchase of the AccuTools el-720 Carbon Dioxide Gas Leak Detector, the most technologically advanced instrument of its kind.
Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions
Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions Description The Flame Integrated Sampling System (FLAME-DA-CUV-UV-VIS) is a snap-on, direct-attach 1 cm cuvette
Sip/Puff Switch User Guide
Sip/Puff Switch User Guide www.orin.com Table of Contents Table of Contents... 2 Legal Notices... 3 Declaration of Conformity with European Directives... 3 Application Disclaimer... 4 Introduction... 5
TEMPERATURE SENSOR USER MANUAL
TEMPERATURE SENSOR USER MANUAL 1 Temperature sensor user manual Copyright 2012 Unisense A/S Version October 2012 TEMPERATURE SENSOR USER MANUAL UNISENSE A/S TABLE OF CONTENTS WARRANTY AND LIABILITY....8
INSTRUCTIONS 56-1190-98. Edition AC
Sephacryl S-100 High Resolution Sephacryl S-200 High Resolution Sephacryl S-300 High Resolution Sephacryl S-400 High Resolution Sephacryl S-500 High Resolution INSTRUCTIONS Sephacryl High Resolution chromatography
Ozone Generator Manual
ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 Ozone Generator Manual 80003-118 MCN-282, 05/14/04 Table of Contents 1.0 INTRODUCTION... 1 1.1 Unpack...1 1.2 Check Order...1 1.3 Serial Numbers...1
For safety information, see the ABI PRISM 310 Genetic Analyzer User s Manual (PN 903565 or 4317588).
User Bulletin ABI PRISM 310 Genetic Analyzer 01/2007 SUBJECT: Syringe Care and Maintenance Overview Safety Information Warranty Information In this User Bulletin This user bulletin describes the care,
Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy
Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy UV/VIS AND UV/VIS/NIR SPECTROSCOPY A P P L I C A T I O N N O T E Introduction The availability and applications of fiber optic sampling in UV/Vis
Chapter 28: High-Performance Liquid Chromatography (HPLC)
Chapter 28: High-Performance Liquid Chromatography (HPLC) Scope Instrumentation eluants, injectors, columns Modes of HPLC Partition chromatography Adsorption chromatography Ion chromatography Size exclusion
Operators Manual SOIL COMPACTION TESTER
Operators Manual SOIL COMPACTION TESTER ENGLISH DOCU-M0116 03-10 Introduction THANK YOU for purchasing the Soil Compaction Tester. READ THIS MANUAL carefully to learn how to operate and service your Soil
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration
Operator Quick Guide EC SENSOR
Operator Quick Guide EC SENSOR Revision G - 24/04/2008 General Information About This Guide The information in this guide has been carefully checked and is believed to be accurate. However, Hach Ultra
81000 Series Aluminum Gate Valve Installation and Repair Manual
High Vacuum Valves Leader in Quality and Value 81000 Series Aluminum Gate Valve Installation and Repair Manual Dear Customer, Thank you for choosing HVA as your vacuum valve supplier. Your valve will give
3 WATT LED SPOTLIGHT Model No. SLM - 3801
3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging
Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM
Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability is assumed
Single-Use Flow-Through Cell ph FTC-SU-HP8
Single-Use Flow-Through Cell ph FTC-SU-HP8 SENSOR PROBES Instruction Manual Single-Use Flow-Through Cell ph FTC-SU-HP8 Specification: ph sensor stick integrated in a single-use flow-through cell Document
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual
Dissolved Oxygen Sensors
Instruction Sheet PN 51A-HxDO/rev.F June 2008 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit
The photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
Infrared Viewers. Manual
Infrared Viewers Manual Contents Introduction 3 How it works 3 IR viewer in comparison with a CCD camera 4 Visualization of infrared laser beam in mid-air 4 Power Density 5 Spectral sensitivity 6 Operation
Geocontrol PRO INSTALLATION AND OPERATION MANUAL. Rev. 1 03/18/04 Part # 11150263
Geocontrol PRO INSTALLATION AND OPERATION MANUAL Rev. 1 03/18/04 Part # 11150263 TABLE OF CONTENTS Chapter 1: System Description... p. 05 Function and Theory...p. 05 Chapter 2: System Installation... p.
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
Amplified High Speed Fiber Photodetectors
Amplified High Speed Fiber Photodetectors User Guide (800)697-6782 [email protected] www.eotech.com Page 1 of 7 EOT AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE Thank you for purchasing your Amplified
Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents
Operator s Manual Pressure Injection Cell Model PC8500 Congratulations! Congratulations on your purchase of a Next Advance Pressure Injection Cell. Please read this operator s manual which explains proper
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Tipping Bucket Rain Gauge Models 6011-A 6011-B
Tipping Bucket Rain Gauge Models 6011-A 6011-B User s Manual 1165 National Drive Sacramento, CA 95834 800.824.5873 Table of Contents General Information... 1 Introduction... 1 Installation General... 2
Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1
REMOTE METER TM Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English 990-2485B 02/2009 Introduction About this UPS The American Power Conversion (APC ) SURT192RMXLBP2 external
staple gun with 5/16 Long staples
staple gun with 5/16 Long staples Model 95718 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks
WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL
WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL CAUTION: This system is not for use with antenna in raised position while
cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.
- Easy -wire installation with no external spark box necessary, but can be used with one. - Precision CNC machining and hand assembled construction. This is a premium product. - Accurate super hot spark
Universal Wireless Effects Controller USER S GUIDE SA115
Universal Wireless Effects Controller USER S GUIDE SA115 Welcome Thank you for purchasing this Hot Hand 3 Universal Wireless Effects Controller. We hope that the new functionality of the Hot Hand 3 unit
IR Repeater. Operation Manual P8620
IR Repeater Operation Manual P8620 Congratulations on your purchase of the P8620 IR Repeater. This operating manual will provide a guide to installation and operation of the product. Please read thoroughly
Hydraulic Punch Driver Kit
Hydraulic Punch Driver Kit Item 96718 Instructions and precautions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious
Mini-led spotlight with magnetic base
Mini-led spotlight with magnetic base Model 95799 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
DSM155 Digital LED Light Meter User s Manual DSM155
DSM155 Digital LED Light Meter User s Manual DSM155 CONTENTS TABLE OF CONTENTS......3 LIMITED WARRANTY AND LIMITATION OF LIABILITY......3 Out of Box....3 Accessories....3 Safety Information....3 Certification....5
Trace Dissolved Oxygen Sensor
Instruction Sheet PN 51A-499ATRDO/rev.G September 2010 Model 499A TrDO Trace Dissolved Oxygen Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION
SE-100-1, SE-200-1, SE-500-1, and SE-1000-1 AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81) 83 54 10 18 ventas@industrialmagza.
AIR CHAMP PRODUCTS User Manual SE BRAKE MODELS: SE-00-, SE-200-, SE-500-, and SE-000- (i) FORM NO. L-20084-E-040 In accordance with Nexen s established policy of constant product improvement, the specifications
How To Use The Visifault Visual Fault Locator
VisiFault Visual Fault Locator Instruction Sheet The VisiFault Visual Fault Locator (VFL) is a visible light source that helps you trace optical fibers, check fiber continuity, and find faults such as
In-Line Filters and Coalescers with Automatic Drains
Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid
Operating Manual FINGERSIM SET 3-349-631-03 1/5.11. for SECULIFE NIBP in Combination with SECULIFE OX1
Operating Manual FINGERSIM SET for SECULIFE NIBP in Combination with SECULIFE OX1 3-349-631-03 1/5.11 CONTENTS 1 GENERAL WARNINGS AND CAUTIONS... 4 2 PURPOSE... 5 3 DESCRIPTION... 6 4 THEORY OF OPERATION...
WARNING: This product contains chemicals known to the state of California to cause cancer, or birth defects or other reproductive harm.
WARNING: This product contains chemicals known to the state of California to cause cancer, or birth defects or other reproductive harm. 9780 SW Freeman Drive Wilsonville, OR 97070 USA Tel: 800-442-2406
ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS
1 ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS Buck Scientific Atomic Absorption Spectrophotometer, Model 200 Atomic absorption spectroscopy (AAS) has for many years
CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual
CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS Products Include: 60 gpm eductors Style 3060, 3061, 3062 & 3070 95 gpm eductors Style
Periodic Verification System Model 775PVS
Periodic Verification System Model 775PVS Instruction Manual Contents 1 Description... 1 775PVS System... 1 Model 775 Fieldmeter... 2 Model 775C Charger... 2 Model 775P Plate Assembly... 3 2 Operation...
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual
ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual Catalog numbers 780-1070 780-1650 Please read these instructions before you use ENrich SEC high-resolution size exclusion
Stereoscopic 3D Digital Theater System. Operator Manual (MI-2100)
Stereoscopic 3D Digital Theater System Operator Manual (MI-2100) -1- All information contained in or disclosed by this document is confidential and propriety to masterimage Co., Ltd. (hereinafter referred
PART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
ExStik TM ph Waterproof Meters
User Guide ExStik TM ph Waterproof Meters Models PH100 & PH110 Patent Pending ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE / HOLD button 4. CAL / RECALL
HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies
HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies Application Note Small Molecule Pharmaceuticals Authors Jignesh Shah, Tiantian Li, and Anil Sharma Agilent Technologies,
Fiber Optic Cable Installation
Quick Guide Fiber Optic Cable Installation Introduction Fiber optic cables can be easily damaged if they are improperly handled or installed. It is imperative that certain procedures be followed in the
Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports
Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports (800-0037) Doc. PUBTPASXSFPU Rev., 07/08 Contents Introduction.... Key Features... Unpacking and Inspection....3 Product
CUNO TM Series NB Bags for Liquid Filtration
CUNO TM Series NB Bags for Liquid Filtration Customers have relied on CUNO to provide quality filtration solutions for the most demanding applications. Leveraging 3M innovation, CUNO has applied this expertise
How To Install A Power Supply (Uplast) With A Battery Pack
APC Smart-UPS RT SURTA48XLBP/SURTA48XLBPJ External Battery Pack User Manual Introduction/Before Installation About this Manual The APC Smart-UPS RT external battery pack (SURTA48XLBP or SURTA48XLBPJ) connects
User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions
LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions Description The LS-1 Series of tungsten halogen light sources are versatile, white-light lamps optimized for use in the
Operation Manual For NDJ-8S Digital Rotary Viscometer
Operation Manual For NDJ-8S Digital Rotary Viscometer 1 Contents 1. General... 2 2. Main technical data... 2 3. Working principle... 2 4. Installation... 3 5. Operation procedures... 4 6. Precautions...
User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM
User s Guide Shop online at omega.com SM e-mail: [email protected] For latest product manuals: www.omegamanual.info OSXL-100-PE Thermal Imaging Camera Enclosure Introduction Please read this manual completely
Using the Spectrophotometer
Using the Spectrophotometer Introduction In this exercise, you will learn the basic principals of spectrophotometry and and serial dilution and their practical application. You will need these skills to
SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions
SBC90 Abrasive Blast Cabinet Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides important
Optical Power Meter. Specification & User Manual
Optical Power Meter Specification & User Manual Page 1 of 9 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4
User Guide. HDMI Active Cable Extender. DVI-7370c
User Guide HDMI Active Cable Extender DVI-7370c TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY...1 1.0 INTRODUCTION...2 2.0 SPECIFICATIONS...3 3.0 PACKAGE CONTENTS...4 4.0 CONNECTING
Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930
Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930 WARNING Ultraviolet light is harmful to eyes and skin. Never look at light produced by this lamp. Unplug lamp before servicing. Electrical
DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.
PW4 Pressure Chart Recorders Contents: Applications and Useful Features Operating Instructions / Getting Started Calibrations Troubleshooting Warranty / Factory Service & Applications The PW4 Weather Resistant
Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented
User's Guide Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented Introduction Congratulations on your purchase of Extech's Laser Photo/Contact Tachometer with Non- Contact IR Thermometer,
Dual Laser InfraRed (IR) Thermometer
User s Manual Dual Laser InfraRed (IR) Thermometer MODEL 42511 Introduction Congratulations on your purchase of the Model 42511 IR Thermometer. This Infrared thermometer measures and displays non-contact
Hydraulic Transmission Jacks Operating Instructions & Parts Manual
Blackhawk Automotive is a Licensed Trade Mark Made by SFA Companies, Kansas City, MO Hydraulic Transmission Jacks Operating Instructions & Parts Manual Model BH7011 BH7210 Capacity 1/2 Ton 1 Ton SFA Companies
TROUBLESHOOTING FLOW CHART
TROUBLESHOOTING FLOW CHART Revised and updated on January 16, 2003, by Tony Leger and Automation Lab Technology. FACScan(FC)\FACSort(FST) FACScalibur (FCB) Fluidics/Pneumatics troubleshooting guide DCM
RGC-IR Remote Gas Calibrator for IR400
Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by
We reserve the right to make technical changes.
User Guide External Hard Disk with USB 1.1/2.0 and IEEE 1394 connection Copyright 2003 All rights reserved. This manual is protected by Copyright. The Copyright is owned by Medion. Trademarks: MS-DOS and
HIH-4000 Series Humidity Sensors
HIH-4000 Series Humidity Sensors DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users. Direct input to a controller or
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
Rheodyne Manual Sample Injector Valves
Rheodyne Manual Sample Injector Valves Rotor Seal Shaft End Rotor Seal Groove Stator Face Stator Stator Face Seal Rotor Seal Grooves Position A Rotor Seal Grooves Position B Position C Flow paths showing
2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN-00076-A
2-3 SAS/SATA II HDD Canister XC-23D1-SA10-0-R USER S MANUAL Document number: MAN-00076-A ii Preface Important Information Warranty Our product is warranted against defects in materials and workmanship
REDOX AND REFERENCE ELECTRODE USER MANUAL
REDOX AND REFERENCE ELECTRODE USER MANUAL 3 Redox and reference electrode manual Copyright 2012 Unisense A/S Version October 2012 REDOX AND REFERENCE ELECTRODE MANUAL UNISENSE A/S TABLE OF CONTENTS WARRANTY
EZ-PAGE Electrophoresis System USER MANUAL
EZ-PAGE Electrophoresis System USER MANUAL Table of Contents Safety Information.. 2 Product Description... 2 Product Contents..... 3 Specifications & Storage Conditions.. 3 Product Use..... 3 Getting Started
Acrylic Walls Installation Instructions
Acrylic Walls Installation Instructions IMPORTANT Please read carefully the following instructions before installing your shower acrylic walls. If you have any questions on this shower acrylic walls installation
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
ÄKTA system Training Guide
ÄKTA system Training Guide Explorer 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bioscience ÄKTAexplorer ÄKTAexplorer Buffers Injector Box amersham bioscience Monitor Conductivity
Imation Disc Stakka Setup Guide
Imation Disc Stakka Setup Guide Installing your Disc Stakka Requirements Pentium II or G3 processor (minimum) Microsoft XP, 2000 (SP4), 98SE, ME or Mac OS X (v10.1 or higher) 32 MB RAM (minimum), 64 MB
USB-ISS-UV/VIS Integrated Sampling System Installation and Operation Instructions
USB-ISS-UV/VIS Integrated Sampling System Installation and Operation Instructions Description The USB-ISS-UV/VIS Integrated Sampling System is a snap-on, direct-attach 1 cm cuvette holder and UV/VIS/NIR
User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.
User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.
Owner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
Dual Laser InfraRed (IR) Thermometer with Color Alert
User Manual Dual Laser InfraRed (IR) Thermometer with Color Alert MODEL 42509 Introduction Congratulations on your purchase of the Model 42509 IR Thermometer with Color Alert. This Infrared thermometer
Park 250 Brushless Outrunner Instructions
Park 250 Brushless Outrunner Instructions Thank you for purchasing the E-flite Park 250 Brushless Outrunner motor. This motor is ideal for 3D models 4-6 oz (115-170g), and sport and scale models 6-12 oz
Instruction Manual HI 96800 Refractometer for Refractive Index and Brix Measurements
Instruction Manual HI 96800 Refractometer for Refractive Index and Brix Measurements www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction
Magnetic Stripe Reader-Writer. Magnetic Stripe Reader-Writer. RS232 & USB-RS232 Interface Quickstart Manual
Magnetic Stripe Reader-Writer RS232 & USB-RS232 Quickstart Manual ID TECH 10721 Walker Street Cypress, California 90630 (714) 761-6368 www.idtechproducts.com 80058504-002 Rev. C R01/08 Magnetic Stripe
FIBRE-OPTICS POWER METER INSTRUCTION MANUAL
FIBRE-OPTICS POWER METER INSTRUCTION MANUAL FIBRE-OPTICS POWER METER ELLMAX ELECTRONICS LTD. Unit 29, Leyton Business Centre, Etloe Road, Leyton, London E10 7BT, England Tel: 020-8539 0136 Fax: 020-8539
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
ph Measurement and Control
ph Measurement and Control Tech Tip #14 1997 I. The Need for ph II. ph System Requirements III. ph Electrode Conditioning Procedures IV. How the electrode works V. Identifying the Electrode Components
Mold Alert... Operation Manual P0270
Mold Alert... Operation Manual P0270 introduction Congratulations on your purchase of the P0270 Mold Alert! Mold is as old as the Earth and it s everywhere. Under the right set of conditions, it can actually
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline
EXPERIMENT 5 Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline UNKNOWN Submit a clean, labeled 100-mL volumetric flask to the instructor so that your unknown iron solution