Switch Mode Power Supply S8VS
|
|
|
- Jessie French
- 9 years ago
- Views:
Transcription
1 Switch Mode Supply S8VS 15/30-W Models Compact, Thin Supplies That Mount Just About Anywhere to Contribute to Control Panel Downsizing Compact, thin size: mm (W H D). Three mounting directions (standard, horizontal, facing horizontal). Mounting directly onto the panel is possible. Safety standards: UL508/ /1604, CSA C / /213, EN50178 (= VDE0160), EN (= VDE0805). 60/90/120/180/240-W Models New Models with Total Run Time Monitor in Addition to Models with Maintenance Forecast Monitor Compact size: mm (W H) (60-W Models). Status displayed on 3-digit, 7-segment display. Safety standards: UL508/60950, CSA C /60950, EN50178 (= VDE0160), EN60950 (= VDE0805). Features Common to All Models Mount to DIN-rail. Lead-free solder. Switch Mode Supply S8VS B-5
2 Model Number Structure Model Number Legend S8VS Ratings 015: 15 W 030: 30 W 060: 60 W 090: 90 W 120: 120 W 180: 180 W 240: 240 W 2. Output voltage 05: 5 V 12: 12 V 24: 24 V 3. Configuration 15-W, 30-W Models ne: Standard 60-W Models ne: Standard A: With maintenanc B: With total run 90-W, 120-W, 180-W, 240-W Models ne: Standard A: With maintenanc and undervoltage alarm (transistor (sinking)) B: With total run and undervoltage alarm (transistor (sinking)) AP: With maintenanc and undervoltage alarm (transistor (sourcing)) BP: With total run and undervoltage alarm (transistor (sourcing)) Ordering Information ratings Input Voltage Output voltage Output current Alarm output Model number 15 W 100 to 240 VAC 5 V 2.0 A --- S8VS V 1.2 A S8VS V 0.65 A S8VS W 5 V 4.0 A --- S8VS (See note 2.) 12 V 2.5 A S8VS V 1.3 A S8VS W 24 V 2.5 A --- S8VS S8VS-06024A S8VS-06024B 90 W 3.75 A --- S8VS S8VS-09024A S8VS-09024AP S8VS-09024B S8VS-09024BP 120 W 5 A --- S8VS S8VS-12024A S8VS-12024AP S8VS-12024B S8VS-12024BP 180 W 7.5 A --- S8VS S8VS-18024A S8VS-18024AP S8VS-18024B S8VS-18024BP 240 W 10 A --- S8VS S8VS-24024A S8VS-24024AP S8VS-24024B S8VS-24024BP te: 1. The output capacity of the S8VS is 10 W. 2. The output capacity of the S8VS is 20 W. B-6 Switch Mode Supply S8VS
3 Specifications Ratings/Characteristics ratings 15 W 30 W Type Standard Standard Efficiency (typical) 5-V models 72% min. (76% 70% min. (76% 12-V models 74% min. (79% 76% min. (83% 24-V models 77% min. (81% 80% min. (85% 50/60 Hz (47 to 450 Hz) Current 100 V input 0.45 A 0.9 A 200 V input 0.25 A 0.6 A 230 V input 5 V: (0.14 A, 12 V/24 V (0.19 A 5 V: (0.27 A, 12 V/24 V (0.37 A factor --- Leakage current 100 V input 0.5 ma 200 V input 1.0 ma 230 V input 5 V/12 V/24 V: (0.30 ma 5 V/12 V/24 V:(0.32 ma Output Additional Voltage adjustment range (See note 2.) 100 V input 25 A (20 A (for a cold start at 25 C) 200 V input 50 A (40 A (for a cold start at 25 C) 230 V input 5 V/12 V/24 V: (29 A 5 V/12 V/24 V: (40 A f=20mhz measuring 10% to 15% (with V.ADJ) (guaranteed) 2.0% (p-p) (at rated input/output voltage) 5 V: (0.70%(p-p), 12 V:(0.48%(p-p), 24 V:(0.25%(p-p) f=100mhz measuring 5 V: (0.86%(p-p), 12 V:(0.56%(p-p), 24 V:(0.32%(p-p) 0.5% (at 85 to 264 VAC input, 100% load) 5 V: (0.70%(p-p), 12 V:(0.52%(p-p), 24 V:(0.19%(p-p) 5 V: (0.80%(p-p), 12 V:(0.58%(p-p), 24 V:(0.21%(p-p) Load variation influence (rated input voltage) 2.0% (5 V), 1.5% (12 V, 24 V), (with rated input, 0 to 100% load) 0.05%/ C Start up (See note 1 and 7.) 100 ms (at rated input/output voltage) 1,000 ms (at rated input/output voltage) 5 V: (6 ms, 12 V: (12 ms, 24 V: (18 ms 5 V/12 V/24 V: (240 ms at 100% load 5 V: (328 ms, 12V: (251 ms, 24 V: (243 ms 5 V: (299 ms, 12 V: (217 ms, 24 V: (210 ms Overload protection 105% to 160% of rated load current, voltage drop, automatic reset 105% to 160% of rated load current, voltage drop, intermittent operation, automatic reset Overvoltage protection (a zener diode clamp) (See note 3.) (See note 4.) Output voltage indication Output current indication Peak-hold current indication Maintenanc indication Maintenanc output Total run indication Total run output Undervoltage alarm indication (color: red) Undervoltage alarm output Models with 24-V output: Possible for up to 2 Supplies (with external diode) Models with 5- or 12-V output: t possible 3.0 kvac for 1 min. (between all inputs and outputs; detection current: 20 ma) 1.0 kvac for 1 min. (between all outputs and PE terminals; detection current: 20 ma) 100 MΩ min. (between all outputs and all inputs/ PE terminals) at 500 VDC 10 to 150 Hz, 0.35-mm single amplitude (5 G ) for 80 min. each in X, Y, and Z directions (color: green) Conducted Conforms to EN EN55011 Class B and based on FCC Class A Conforms to EN EN55011 Class B UL: UL508 (Listing, Class 2: Per UL1310), UL , UL1604 (Class I/Division2) cul: CSA C (Class 2), ,.213 (Class I/Division2) EN/VDE: EN50178 (=VDE0160), EN (=VDE0805) Weight 160 g 180 g te: 1. Refer to the Engineering Data section on page B-21 for details. 2. If the V.ADJ adjuster is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Supply and be sure that the load is not damaged. 3. The overvoltage protection of the S8VS-015@@ uses a zener diode clamp. If the internal feedback circuit is destroyed by any chance, the load may be destroyed by the clamped output voltage (approx. 140% to 190% of the rated output voltage). 4. To reset the protection, turn OFF the power supply for three minutes or longer and then turn the power supply back ON. 5. The typical values indicate the values for an input condition of 230 VAC. All items are measured at a frequency of 50 Hz. 6. The inrush current circuits do not differ for voltage specifications. Therefore, the typical values are the data values for 24-V models. 7. The circuit forms are different, so the start up is shorter only when using a 15-W power rating. Switch Mode Supply S8VS B-7
4 Specifications Ratings/Characteristics ratings 60 W 90 W Type Standard Maintenance Total run Standard Maintenance forecast forecast Efficiency (typical) 78% min. (86% 80% min. (87% 50/60 Hz (47 to 450 Hz) Current 100 V input 1.7 A 2.3 A 200 V input 1.0 A 1.4 A 230 V input (0.7 A (0.9 A factor --- Leakage current 100 V input 0.5 ma 200 V input 1.0 ma 230 V input (0.40 ma (0.35 ma 100 V input 25 A (for a cold start at 25 C) 200 V input 50 A (for a cold start at 25 C) 230 V input (47 A (38 A Total run Output Voltage adjustment range (See note 2.) 10% to 15% (with V.ADJ) (guaranteed) 2.0% (p-p) (at rated input/output voltage) f=20mhz measuring (0.29% (p-p) (0.38% (p-p) f=100mhz measuring (0.32% (p-p) (0.42% (p-p) 0.5% (at 85 to 264 VAC input, 100% load) Load variation influence (rated input voltage) 1.5% (with rated input, 0 to 100% load) 0.05%/ C Start up 1,000 ms (at rated input/output voltage) (270 ms (260 ms at 100% load (220 ms (190 ms Additional Overload protection 105% to 160% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection (See notes 1 and 3.) Output voltage indication (See note 4.) Output current indication (See note 4.) Peak-hold current indication (See note 4.) (See note 7.) (See note 7.) Maintenanc indication (See note 4.) Maintenanc output (open, 50 ma Total run indication (See note 4.) Total run output (open, 50 ma Undervoltage alarm indication (See note 4.) Undervoltage alarm output terminals output) for up to 2 Supplies (with external diode) 3.0 kvac for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 ma) 1.0 kvac for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current: 20 ma) 500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 ma) 100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC 10 to 150Hz, 0.35-mm single amplitude (5 G ) for 80 min each in-x, Y, and Z directions (color: green) Conducted Conforms to EN EN55011 Class A and based on FCC Class A Conforms to EN EN55011 Class A UL: UL508 (Listing, Class 2: Per UL1310), UL60950 cul: CSA C (Class 2), Weight 330 g 490 g UL: UL508 (Listing), UL60950 cul: CSA C , te: 1. Refer to the Engineering Data section on page B-21 for details. 2. If the V.ADJ adjuster is turned, the voltage will increase by more than +15% of the voltage adjustment range (by more than +10% for 240-W models). When adjusting the output voltage, confirm the actual output voltage from the Supply and be sure that the load is not damaged. 3. To reset the protection, turn OFF the power supply for three minutes or longer and then turn the power supply back ON. 4. Displayed on 7-segment LED. (character height: 8 mm) 5. Resolution of output voltage indication: 0.1 V, Precision of output voltage indication: ±2% (percentage of output voltage value, ±1 digit) 6. Resolution of output current indication: 0.1 A; Precision of output current indication: ±5% F.S. ±1 digit (specified by rated output voltage) 7. Resolution of peak-hold current indication: 0.1 A; Precision of peak-hold current indication: ±5% F.S. ±1 digit (specified by rated output voltage); Signal width required for peak-hold current: 20 ms 8. A Type and B Type:, AP Type and P Type: 9. To ensure the emission rating, a ferrite ring core should be used in all cabling (TDK HF60T, HF70RH or equivalent model). 10. The typical values indicate the values for an input condition of 230 VAC. All items are measured at a frequency of 50 Hz. B-8 Switch Mode Supply S8VS
5 ratings 120 W 180 W 240 W Type Standard Maintenanc Total run Standard Maintenanc Total run Standard Maintenanc Efficiency (typical) 80% min. (87% 80% min. (88% 80% min. (86% 50/60 Hz (47 to 63 Hz) Current 100 V input 1.9 A 2.9 A 3.8 A 200 V input 1.1 A 1.6 A 2.0 A 230 V input (0.6 A (0.9 A (1.2 A factor 0.95 min. Leakage current 100 V input 0.5 ma 200 V input 1.0 ma 230 V input (0.43 ma (0.45 ma (0.45 ma 100 V input 25 A (for a cold start at 25 C) 200 V input 50 A (for a cold start at 25 C) 230 V input (41 ma (34 ma (39 ma Output Voltage adjustment range (See note 2.) 10% to 15% (with V.ADJ) (guaranteed) ±10% (with V.ADJ) (guaranteed) 2.0% (p-p) (at rated input/output voltage) f=20mhz measuring (0.66%(p-p) (0.45%(p-p) (0.13%(p-p) f=100mhz measuring (0.67%(p-p) (0.52%(p-p) (0.21%(p-p) 0.5% (at 85 to 264 VAC input, 100% load) Load variation influence (rated input voltage) 1.5% (with rated input, 0 to 100% load) 0.05%/ C Start up 1,000 ms (at rated input/output voltage) (380 ms (530 ms (780 ms at 100% load (60 ms (60 ms (30 ms Additional Total run Overload protection 105% to 160% of rated load current, voltage drop, intermittent, automatic reset 105% to 160% of rated load current, voltage drop, automatic reset Overvoltage protection (See notes 1 and 3.) Output voltage indication (See note 4.) Output current indication (See note 4.) Peak-hold current indication (See note 4.) (See note 7.) Maintenanc indication (See note 4.) Maintenanc output Total run indication (See note 4.) Total run output (open (See note 7.) (See note 7.) (open (open Undervoltage alarm indication (See note 4.) Undervoltage alarm output terminals (open (open (open for up to 2 Supplies (with external diode) 3.0 kvac for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 ma) 1.0 kvac for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current: 20 ma) 500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 ma) 100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC 10 to 150Hz, 0.35-mm single amplitude (5 G ) for 80 min each in-x, Y, and Z directions (color: green) Conducted Conforms to EN EN55011 Class A and based on FCC Class A Conforms to EN EN55011 Class A UL: UL508 (Listing), UL60950 cul: CSA C , SELV (EN60950/UL50178/UL ) Weight 550 g 850 g 1,150 g Switch Mode Supply S8VS B-9
AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models
TML Series, 0 & 0 Watt Features C B Scheme LVD UL 090- Encapsulated power supplies with increased power density Replaces TML and TML 0 series PCB mount or chassis mount with screw terminals Single, dual
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Preset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
EGSTON Standard E2xFxWx 12W
General description The family of switchmode power supplies offers an unmatched degree of flexibility and performance fulfilling even the most stringent requirements. Highly flexible electrical configuration
RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,
APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP
SKR - industry relay
SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,
MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
Single Output Switching Power Supply
.. RS- Code: CLP-A Single Output Switching Power Supply SPECIFICATION MODEL OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY EMC (Note 6) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE
650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications
Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection
1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
UMEC International Corporation
UP1301A SERIES 130 Watt Open Frame Switchers Small Size 3*5*1.2(inches) Universal Input to 264 VAC Low Power Consumption Overvoltage Protection Continuous Short Circuit Protection Over Temperature Protection
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
MAXIMUM LOAD CURRENT 1 A SN SERIES
SOLID STATE RELAY (I/O Module) MAXIMUM LOAD CURRENT 1 A SN SERIES RoHS compliant FEATURES I/O modules for interface between CPU and external input devices or loads Ultra slim and light weight, SIL s type
I STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
Actuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES
FTR-K1 SERIES SILENT POWER RELAY 1 POLE - 78A/120A Inrush Current Type FTR-H3 Series FEATURES Pin compatible with widely used VS and FTR-H1 series power relays Silent relay with patented unique U-shape
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
650W Single Output Power Supply
AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS
Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD Present Value: 8 mm (.32 in) Set Value: 4 mm (.16 in) Nonsignificant
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) HIGH INSULATION Insulation distance (between coil and
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Control Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE
POWER ROCKER SWITCH SWITCHES AJ8 switch standard actuator AJ8 switch Wide actuator RoHS Directive compatibility information http://www.nais-e.com/ FEATURES 1. Power rocker switches for safety requirements.
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
EPSON Perfection 1650/1650 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. device Effective pixels
Scanner Parts Start and indicator light Photo Print USB port The has a transparency unit built into the scanner lid and holder for 35 mm film and slides: EPSON Perfection 1650 owners can purchase an optional
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES
FTR-K1 SERIES MINIATURE RELAY 2 POLES - 1 to 2 A (For Signal Switching) NA Series FEATURES Slim type relay for high density mounting Conforms to Telcordia specification and FCC Part 68 - Dielectric strength
HYDRUS ULTRASONIC METER
HYDRUS APPLICATION HYDRUS is a static water meter based on the ultrasonic technology. This technology enables accurate calculation of water consumption and eliminates measuring deviations caused by sand,
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
Multifunction Digital Timer
Multifunction Digital Timer 1/16 DIN Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.
EPL225 Series. 225 Watts. www.xppower.com. AC-DC Power Supplies. Models & Ratings. Summary
225 Watts 50 W Convection/ 225 W Forced-cooled Ratings 2 by 4 Footprint Low.26 Profile 2 V Fan Output High Efficiency, up to 95% ITE & Medical pprovals High Power Density Less than 0.5 W No Load Input
Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC
Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
Preventa Machine Safety Products
Preventa Machine Safety Products Catalog 2009 200 Supplement Safety Relay Modules 2 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop
NX safety stand-alone
NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O
Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting
Adding Pneumatic Preset Counter Type 497 Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting VARIABLE PILOT SIGNAL Using two pneumatic preset counters
Model Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
Series AMLDL-Z Up to 1000mA LED Driver
FEATURES: Click on Series name for product info on aimtec.com Series Up to ma LED Driver Models Single output Model Input Voltage (V) Step Down DC/DC LED driver Operating Temperature range 4ºC to 85ºC
Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)
Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum
Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)
Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating
3-phase, bidirectional energy meter
Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured
PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN --- --- contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND --- ---
PCB Relay A Power Relay for a Variety of Purposes with Various Models Conforms to VDE045 (VDE approval: C2 insulation grade), UL8, CSA22.2, SEV, SEMKO. Meets VDE0700 requirements for household products
7 - Phaseo power supplies and transformers
/0 Contents 0 - Phaseo power supplies and transformers Selection guide: Phaseo power supplies Modular, Optimum and universal ranges........................ page /2 Selection guide: Phaseo power supplies
SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
A SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant
MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) A SERIES RoHS compliant FEATURES Extremely low profile and light weight Height: 5 mm Weight: approximately 1.2 g Meet FCC (Part 68) standard Conforms
MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER
Bulletin No. IFMA-E Drawing No. LP0340 Released 5/06 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER SIMPLE ON-LINE RANGE SETTING (Using
ATC-300 Automatic Transfer Switch Controller
ATC-300 Technical Data New Information Technical Data Page 2 Effective: May 2004 ATC-300 Introduction The Cutler-Hammer ATC-300 from Eaton s Electrical business is a comprehensive, multi-function, microprocessor-based
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) High insulation Insulation distance (between coil and
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port MODEL NUMBER: OMNIVS1500 Highlights 1500VA / 1.5kVA tower 120V line-interactive UPS Corrects brownouts and overvoltages from 75 to 147V
Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long
Surfacemounting Relay Ultracompact and Slim DPDT Relay Suitable for highdensity mounting.(.7 mm (W). mm (L) 9 mm (H)). Dielectric strength of, VAC and an impulse withstand voltage of 2, V for 2 μs (conforms
EPSON Perfection 2450 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. US letter or A4 size (8.5 11.7 inches [216 297 mm])
Scanner Parts Start button power button (TPU) under lid IEEE 1394 port Scanner Specifications Basic Specifications Scanner type Photoelectric device Effective pixels USB port indicator light document cover
Basic Specifications. Electrical. EPSON Perfection 3170. Color EPSON MatrixCCD TM line sensor. device Effective pixels
Scanner Parts Document table Power cord Document cover Transparency unit (TPU) under lid Web Transparency unit (TPU) connector TPU indicator light e-mail Carriage and lamp (in the home position) USB port
MAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Absolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives
3753 en 04.2004/b Variable speed drives LEROYSOMER's drives provide SPEED VARIATION for a DC motor, SIMPLY and ECONOMICALLY from a singlephase power supply. CMStype technology is used. These products conform
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
AC-DC Single Output Power Module
AC-DC Single Output Power Module PFHC (AC-DC Conversion) and DC-DC Conversion Integrated in One Package. 2-in-1 Design Concept One module now contains the functions previously only obtainable by combining
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Top Microsystems Proprietary Specification P/N: W090015HK-XP 022410RB-082709V.A0 SPECIFICATION
SPECIFICATION High Quality Switching Wallmount Adapter Interchangeable AC Plugs 90-264VAC Input 13.5W 9VDC 1.5A Output P/N: W090015HK-XP ** Specification Approval** This specification (total 11 pages including
1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C
FTR-K1 SERIES POWER RELAY 1 POLE - 16A / Inrush 120A relay FTR-K1-KS Series FEATURES 1 pole 16A, 1 form A or 1 form C Peak inrush current 120A / TV-8 Coil power 400mW High insulation in small package (between
POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES
FTR-K1 SERIES POWER RELAY 1 POLE - 5A/10A Medium Load Control JV Series FEATURES UL, CSA, VDE, SEMKO, CQC recognized UL class B (130 C) wire class Low profile and space saving - Height: 12.5 mm - Mounting
APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog
APC DIN Rail Control Panel Mounting Uninterruptible Power Supply Catalog 2014 Contents Introduction, description... 4 Specifications...5 References....6 Dimensions...7 Wiring diagrams....8 Product reference
Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G 3891 0020
Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G 3891 0020 Built-in Dupline channel generator PROFIBUS-DP slave according to EN 50 170 Certified by the PNO PROFIBUS-DP communication
Smart-UPS On-Line 230 V
Smart-UPS On-Line 230 V Unity output power factor single-phase, double-conversion online UPS with advanced management features A versatile UPS developed for unstable power conditions worldwide Smart-UPS
7.5 Watt AC-DC Switch Power Supply
MAIN FEATURES: 7.5W Small Compact Size PCB Mount Single Output Regulated Output Range : 3.3VDC 24VDC Input Range : 85VAC 265VAC/47 63Hz Or 120VDC 370VDC Very Low Standby Power Consumption < 0.15W Better
Laser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies
25.2W/in 3 power density Internal ORing MOSFET & Current Share Climate Savers Computing efficiency standards Up to 8000W in 1U rack Single and dual output 1U racks PMBus option HFE1600 Series 1600W 1U
Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C
Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS
RY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
WINGLIKE ELECTRONICS CO.,LTD
WINGLIKE ELECTRONICS CO.,LTD SPECIFICATION FOR APPROVAL AC/DC ADAPTOR CUSTOMER: CUSTOMER SPECS INPUT: 100-240V AC 50-60HZ, 5V/2A ADAPTOR OUR MODEL NO.: GM-050200 (UL) E321192 SPECIFICATION NO.: WL1105102
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,
Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
Polyphase kwh Electricity Meter
Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2
Model Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
S-series DC to DC Power Supply
January 2013 Page 1 The DeltaV S-series DC/DC system power supplies are modular, easy to install, and secure Easy to use Flexible and cost-effective Secure Simplified system power Introduction Power your
