SAS-2 Changes. T10/ Revision 1
|
|
|
- Donna Wood
- 9 years ago
- Views:
Transcription
1 Date: March 12, 2007 To: T10 Committee From Brad Besmer, LSI Logic Subject: r1 SAS-2 SES-2 Enclosure connector information Revision History Revision 0 (26 February 2007) First revision Revision 1 (12 March 2007) Incorporated commentes from March 2007 SAS Protocol WG Add ENCLOSURE to New Report General fields Moved Report General fields down in conjunction with Changed Minimum to First Change Maximum to Number Move new SAS Virtual Connector element to 0x2F Overview An enclosure may contain multiple expanders. If one (or more) of the expanders is not functional when the functioning expanders are being queried, there is insufficient information provided to determine slot numbers for end devices that potentially may exist at a later time when the non-functioning expanders resume functionality. In order to resolve this issue, information must be available from ALL expanders within the enclosure. This proposal adds minimum and maximum connector element index values to each expander within the enclosure REPORT GENERAL response. This information then provides sufficient information to infer the device slot. Additionally, adding a new SAS Connector Type for Expander Virtual phys, since there are not physical connectors for these devices. SAS-2 Changes REPORT GENERAL function The REPORT GENERAL function returns general information about the SAS device (e.g., a SAS device contained in an expander device). This SMP function shall be implemented by all management device servers. Working Draft Serial Attached SCSI - 2 (SAS-2) 479
2 T10/1760-D Revision 9 26 January 2007 Table 180 defines the request format. Table 180 REPORT GENERAL request 0 SMP FRAME TYPE (40h) 1 FUNCTION (00h) 2 3 REQUEST LENGTH (00h) 4 (MSB) 7 CRC The SMP FRAME TYPE field shall be set to 40h. The FUNCTION field shall be set to 00h. The REQUEST LENGTH field shall be set to 00h. The CRC field is defined in Table 181 defines the response format. Table 181 REPORT GENERAL response (part 1 of 2) 0 SMP FRAME TYPE (41h) 1 FUNCTION (00h) 2 FUNCTION RESULT 3 RESPONSE LENGTH (0Ch0Dh) 4 (MSB) 5 6 (MSB) 7 EXPANDER CHANGE COUNT EXPANDER ROUTE INDEXES 8 9 NUMBER OF PHYS 10 TABLE TO TABLE ZONE ADDRESS RESOLVED CONFIGURES OTHERS CONFIGURING EXTERNALLY CONFIGURABLE ROUTE TABLE ENCLOSURE LOGICAL IDENTIFIER 480 Working Draft Serial Attached SCSI - 2 (SAS-2)
3 Table 181 REPORT GENERAL response (part 2 of 2) (MSB) (MSB) (MSB) 35 STP BUS INACTIVITY TIME LIMIT STP MAXIMUM CONNECT TIME LIMIT STP SMP I_T NEXUS LOSS TIME 36 ZONE LOCKED PHYSICAL PRESENCE PHYSICAL PRESENCE ASSERTED ZONING ZONING ENABLED (MSB) (MSB) MAXIMUM NUMBER OF ROUTED SAS ADDRESSES ACTIVE ZONE MANAGER SAS ADDRESS ZONE LOCK INACTIVITY TIME LIMIT 52 for FIRST ENCLOSURE CONNECTOR ELEMENT INDEX 54 NUMBER OF ENCLOSURE CONNECTOR ELEMENT INDEXES (MSB) 5559 CRC The SMP FRAME TYPE field shall be set to 41h. The FUNCTION field shall be set to 00h. The FUNCTION RESULT field is defined in The RESPONSE LENGTH field shall be set to 0Ch0Dh. For compatibility with previous versions of this standard, a RESPONSE LENGTH field set to 00h indicates that there are 6 dwords before the CRC field. Working Draft Serial Attached SCSI - 2 (SAS-2) 481
4 T10/1760-D Revision 9 26 January 2007 The EXPANDER CHANGE COUNT field counts the number of Broadcast (Change)s originated by an expander device (see 7.11). Management device servers in expander devices shall support this field. management device servers in other device types (e.g., end devices) shall set this field to 0000h. This field shall be set to at least 0001h at power on. If the expander device has originated Broadcast (Change) for any reason described in 7.11 since transmitting a REPORT GENERAL response, it shall increment this field at least once from the value in the previous REPORT GENERAL response. It shall not increment this field when forwarding a Broadcast (Change). This field shall wrap to at least 0001h after the maximum value (i.e., FFFFh) has been reached. NOTE 79 - Application clients that use the EXPANDER CHANGE COUNT field should read it often enough to ensure that it does not increment a multiple of times between reading the field. NOTE 80 - Management device servers in expander devices compliant with previous versions of this standard may return an EXPANDER CHANGE COUNT field set to 0000h. Editor s Note 49: A BROADCAST EXPANDER COUNT field is also needed, so recipients of that BROADCAST can pinpoint which expander it came from. Expander-wide counts for all BROADCASTs (e.g. reception of ASYNCHRONOUS EVENT) might be needed. The EXPANDER ROUTE INDEXES field contains the maximum number of expander route indexes per phy for the expander device (see ). Management device servers in externally configurable expander devices containing phy-based expander route tables shall support this field. Management device servers in other device types (e.g., end devices, externally configurable expander devices with expander-based expander route tables, and self-configuring expander devices) shall set the EXPANDER ROUTE INDEXES field to zero. Not all phys in an externally configurable expander device are required to support the maximum number indicated by this field. The NUMBER OF PHYS field contains the number of phys in the device, including any virtual phys and any vacant phys. A TABLE TO TABLE bit set to one indicates the expander device is a self-configuring expander device that supports its table routing phys being attached to table routing phys in other expander devices. The TABLE TO TABLE bit shall only be set to one if the EXTERNALLY CONFIGURABLE ROUTE TABLE bit is set to zero. A TABLE TO TABLE bit set to zero indicates the expander device is not a self-configuring expander device that supports its table routing phys being attached to table routing phys in other expander devices. A ZONE ADDRESS RESOLVED bit set to one indicates that the zoning expander device supports address resolved zoning. A ZONE ADDRESS RESOLVED bit set to zero indicates that the zoning expander device does not support address resolved zoning (see ). A CONFIGURES OTHERS bit set to one indicates that the expander device is a self-configuring expander device that performs the configuration subprocess defined in 4.8. A CONFIGURES OTHERS bit set to zero indicates the expander device may or may not perform the configuration subprocess. Self-configuring expander devices compliant with this standard shall set the CONFIGURES OTHERS bit to one. NOTE 81 - If the CONFIGURES OTHERS bit is set to zero, the expander device may configure all externally configurable expander devices in the SAS domain. A CONFIGURING bit set to one indicates that either: a) the management device server is in a self-configuring expander device, the self-configuring expander device s management application client is currently performing the discover process (see 4.7), and it has identified at least one change to its expander routing table; or b) the zoning expander device is locked and the zoning expander shadow values differ from the zoning expander active values. A CONFIGURING bit set to zero indicates that the management device server is not in a self-configuring expander device currently performing the discover process and changing its expander routing table. Changes 482 Working Draft Serial Attached SCSI - 2 (SAS-2)
5 in this bit from one to zero result in a Broadcast (Change) being originated (see 7.11). Management device servers in self-configuring expander devices shall support this bit. Management device servers in externally configurable expander devices and in other device types shall set the CONFIGURING bit to zero. An EXTERNALLY CONFIGURABLE ROUTE TABLE bit set to one indicates that the management device server is in an externally configurable expander device that has a phy-based expander route table that is required to be configured with the SMP CONFIGURE ROUTE INFORMATION function (see ). An EXTERNALLY CONFIGURABLE ROUTE TABLE bit set to zero indicates that the management device server is not in an externally configurable expander device (e.g., it is in an end device, in a self-configuring expander device, or in an expander device with no phys with table routing attributes). The ENCLOSURE LOGICAL IDENTIFIER field identifies the enclosure, if any, in which the device is located, and is defined in SES-2. The ENCLOSURE LOGICAL IDENTIFIER field shall be set to the same value reported by the enclosure services process, if any, for the enclosure. An ENCLOSURE LOGICAL IDENTIFIER field set to zero indicates no enclosure information is available. The STP BUS INACTIVITY TIME LIMIT field contains the bus inactivity time limit for STP connections which is set by the CONFIGURE GENERAL function (see ). The STP MAXIMUM CONNECT TIME LIMIT field contains the maximum connect time limit for STP connections which is set by the CONFIGURE GENERAL function (see ). The STP SMP I_T NEXUS LOSS TIME field contains the time that an STP target port and an SMP initiator port retry certain connection requests which is set by the CONFIGURE GENERAL function (see ). A ZONE LOCKED bit set to one indicates that the zoning expander device is locked (see ). A ZONE LOCKED bit set to zero indicates that the zoning expander device is not locked. A PHYSICAL PRESENCE bit set to one indicates that the expander device supports physical presence as a mechanism for allowing zoning to be enabled or disabled from phys in zone groups without access to zone group 2. A PHYSICAL PRESENCE bit set to zero indicates that the expander device does not support physical presence as a mechanism for allowing zoning to be enabled or disabled. A PHYSICAL PRESENCE ASSERTED bit set to one indicates that the expander device is currently detecting physical presence. A PHYSICAL PRESENCE ASSERTED bit set to zero indicates that the expander device is not currently detecting physical presence. The PHYSICAL PRESENCE ASSERTED bit shall be set to zero if the PHYSICAL PRESENCE bit is set to zero. A ZONING bit set to one indicates that zoning is supported by the expander device (i.e., it is a zoning expander device). A ZONING bit set to zero indicates that zoning is not supported by the expander device. A ZONING ENABLED bit set to one indicates that zoning is enabled in the expander device. A ZONING ENABLED bit set to zero indicates that zoning is disabled in the expander device. The ZONING ENABLED bit shall be set to zero if the ZONING bit is set to zero. The MAXIMUM NUMBER OF ROUTED SAS ADDRESSES field contains the number of routed SAS addresses in an expander-based expander route table (see and ). Management device servers in expander devices containing expander-based expander route tables shall support this field. Management device servers in other device types (e.g., end devices and expander devices with phy-based expander route tables) shall set this field to 0000h. The ACTIVE ZONE MANAGER SAS ADDRESS field indicates the SAS address of the zone manager that last locked the zoning expander device. If the zoning expander device is currently being configured by a vendor-specific sideband method then the ACTIVE ZONE MANAGER SAS ADDRESS field shall be set to zero. This field shall be set to zero at power on. The ZONE LOCK INACTIVITY TIME LIMIT field indicates the minimum time between any SMP ZONE LOCK requests, SMP zone configuration function requests, or SMP ZONE ACTIVATE requests from the active zone manager that the locked expander device allows and is set in the SMP ZONE LOCK request (see ). The FIRST ENCLOSURE CONNECTOR ELEMENT INDEX field indicates the first connector element index value returned by any SMP DISCOVER response within the enclosure for any CONNECTOR TYPE values indicating an internal connector (ie. 0x20 through 0x2F). Working Draft Serial Attached SCSI - 2 (SAS-2) 483
6 T10/1760-D Revision 9 26 January 2007 The NUMBER OF ENCLOSURE CONNECTOR ELEMENT INDEXES field indicates the number of connector element index values returned by any SMP DISCOVER response within the enclosure for any CONNECTOR TYPE values indicating an internal connector (ie. 0x20 through 0x2F). NOTE 82 - Assumes that all internal connectors have contiguous CONNECTOR ELEMENT INDEX values. The CRC field is defined in SES-2 Changes: SAS Connector element The SAS Connector element manages a SAS connector or a portion of a SAS connector. The format of the control field for a SAS Connector element is defined in table 182. Table 182 SAS Connector element for control-type diagnostic pages 0 COMMON CONTROL 1 RQST IDENT 2 3 The common control field is specified in A rqst ident (request identify) bit set to one specifies that the enclosure services process identify the element by a visual indication. A rqst ident bit set to zero specifies that the enclosure services process not identify the element by a visual indication. The format of the status field for a SAS Connector element is defined in table 183. Table 183 SAS Connector element for status-type diagnostic pages 0 COMMON STATUS 1 IDENT CONNECTOR TYPE 2 CONNECTOR PHYSICAL LINK 3 The common status field is specified in An ident (identify) bit set to one indicates that the enclosure services process is currently identifying the element by a visual indication because the rqst ident bit was set to one in the control-type diagnostic page. An ident bit set to zero indicates that the enclosure services process is not currently identifying the element by a visual indication based on the rqst ident bit in the control-type diagnostic page, or a visual indication is not implemented. 484 Working Draft Serial Attached SCSI - 2 (SAS-2)
7 The connector type field indicates the type of connector and is defined in table 184. Table 184 CONNECTOR TYPE field Code Description Maximum number of physical links (informative) 00h No information unknown 01h SAS 4x receptacle (see SAS-1.1 and SFF-8470) 4 02h Mini SAS 4x receptacle (see SAS-1.1 and SFF-8088) 4 03h to 0Eh for external connectors 0Fh Vendor-specific external connector unknown 10h SAS 4i plug (see SAS-1.1 and SFF-8484) 4 11h Mini SAS 4i receptacle (see SAS-1.1 and SFF-8087) 4 12h to 1Fh for internal wide connectors 20h SAS Drive receptacle (see SAS-1.1 and SFF-8482) 2 21h SATA host plug (see SAS-1.1 and ATA/ATAPI-7 V3) 1 22h SAS Drive plug (see SAS-1.1 and SFF-8482) 2 23h SATA device plug (see SAS-1.1 and ATA/ATAPI-7 V3) 1 24h to 2E2Fh for internal connectors to end devices 2Fh SAS virtual connector 1 30h to 3Eh for internal connectors 3Fh Vendor-specific internal connector unknown 40h to 6Fh 70h to 7Fh Vendor specific The connector physical link field indicates the physical link in the connector represented by this element. A connector physical link field set to FFh indicates that the element represents the entire connector, not just one physical link in the connector. Physical links in a connector shall be numbered starting with zero. If a connector has only one physical link, the connector physical link field should be set to 00h rather than FFh. Working Draft Serial Attached SCSI - 2 (SAS-2) 485
Users Guide. Serial Attached SCSI (SAS) Interface Manual
Users Guide Serial Attached SCSI (SAS) Interface Manual Users Guide Serial Attached SCSI (SAS) Interface Manual 2003, 2004, 2005, 2006 Seagate Technology LLC All rights reserved Publication number: 100293071,
1 Overview. T10/03-176 revision 9
Date: October 22, 2003 To: T10 Committee (SCSI) From: George Penokie (IBM/Tivoli) Subject: End-to-End Data Protection 1 Overview Any inconsistencies between this section and the remaining sections in the
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters. User Guide
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide September 2010 Revision History Version and Date September 2010 April 2010 March 2010 October 2009 July 2009 Description of
Serial ATA technology
Serial ATA technology Technology brief, 4 th edition Introduction... 2 SATA devices and interoperability with SAS devices... 2 Initiators... 2 Expanders... 3 Targets and their recommended uses... 3 Entry
PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector
PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector StarTech ID: PEXSAT34SFF The PEXSAT34SFF PCI Express SATA Controller Card enables 4 AHCI SATA III connections to
PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering
PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering StarTech ID: PEXSAT34SFF The PEXSAT34SFF PCI Express 2.0 SATA Controller Card enables 4 AHCI SATA III
ATTO ThunderLink Thunderbolt to SAS/SATA Troubleshooting Guide
ATTO ThunderLink Thunderbolt to SAS/SATA Troubleshooting Guide 1 5 5 C r o s s P o i n t P a r k w a y A m h e r s t, N Y 1 4 0 6 8 P. 7 1 6. 6 9 1. 1 9 9 9 F. 7 1 6. 6 9 1. 9 3 5 3 w w w. a t t o t e
3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering
3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering StarTech ID: PEXMSATA343 The PEXMSATA343 3-Port PCI Express 2.0 SATA Card with HyperDuo adds an internal
Intel Solid State Drive Toolbox
3.3.5 Document Number: 325993-026US Intel technologies features and benefits depend on system configuration and may require enabled hardware, software or service activation. Performance varies depending
SCSI The Protocol for all Storage Architectures
SCSI The Protocol for all Storage Architectures David Deming, Solution Technology April 12, 2005 Abstract SCSI: The Protocol for All Storage Architectures This session will appeal to System Administrators,
PCI SATA RAID Card User Manual
PCI SATA RAID Card User Manual Product Features : Chipset: Silicon Image Sil3112 SATA controller chip. Compliant with PCI Specification, Rev. 2.2. Compliant with PCI Plug & Play. 32-bit 33 MHz PCI interface.
ENTTEC Pixie Driver API Specification
ENTTEC Pixie Driver API Specification Purpose This document specifies the interface requirements for PC based application programs to use the ENTTEC Pixie Driver board to drive RGB or RGBW type LED strips.
Intel Solid State Drive Toolbox
3.3.6 Document Number: 325993-027US Intel technologies features and benefits depend on system configuration and may require enabled hardware, software or service activation. Performance varies depending
ExpressSAS Host Adapter 6Gb v2.15 Linux
Product Release Notes ExpressSAS Host Adapter 6Gb v2.15 Linux 1. General Release Information These product release notes define the new features, changes, known issues and release details that apply to
Transitioning to 6Gb/s SAS (Serial-Attached SCSI) A Dell White Paper
Transitioning to 6Gb/s SAS (Serial-Attached SCSI) A Dell White Paper December 2009 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES.
SATA 6G PCIe Card User Manual Model: UGT-ST622
SATA 6G PCIe Card User Manual Model: UGT-ST622 All brand names and trademarks are properties of their respective owners www.vantecusa.com Contents: Chapter 1: Introduction... 3 1.1 Product Introduction...
SCSI Standards and Technology Update: SAS and SCSI Express
SCSI Standards and Technology Update: SAS and SCSI Express Marty Czekalski - President, SCSI Trade Association Seagate Technology Greg McSorley Vice President, SCSI Trade Association - Amphenol SCSI Update
Ethernet. Customer Provided Equipment Configuring the Ethernet port.
Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.
2 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card w/ 2 msata Slots and HyperDuo SSD Tiering
2 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card w/ 2 msata Slots and HyperDuo SSD Tiering StarTech ID: PEXMSATA3422 The PEXMSATA3422 PCI Express SATA Card helps you improve the overall speed
Redundancy in enterprise storage networks using dual-domain SAS configurations
Redundancy in enterprise storage networks using dual-domain SAS configurations technology brief Abstract... 2 Introduction... 2 Why dual-domain SAS is important... 2 Single SAS domain... 3 Dual-domain
LIN (Local Interconnect Network):
LIN (Local Interconnect Network): History: LIN (Local Interconnect Network) was developed as cost-effective alternate to CAN protocol. In 1998 a group of companies including Volvo, Motorola, Audi, BMW,
IDE/ATA Interface. Objectives. IDE Interface. IDE Interface
Objectives IDE/ATA Interface In this part, you will -Learn about each of the ATA standards -Identify the ATA connector and cable -Learn how to set jumpers for master, slave and cable select configurations
04-349r0 SPC-3 MMC-5 Merge PREVENT ALLOW MEDIUM REMOVAL commands 5 November 2004
To: T10 Technical Committee From: Rob Elliott, HP ([email protected]) Date: 5 November 2004 Subject: 04-349r0 SPC-3 MMC-5 Merge PREVENT ALLOW MEDIUM REMOVAL commands Revision history Revision 0 (5 November
6Gb SAS Host Bus Adapter Product Guide
6Gb SAS Host Bus Adapter Product Guide The 6Gb SAS Host Bus Adapter (HBA) is an economical storage enabler to attach RAID-capable external storage enclosures and provide 3 Gbps or 6 Gbps tape storage connectivity
USB 3.0 to SATA 3.5" Enclosure Installation Guide
USB 3.0 to SATA 3.5" Enclosure Installation Guide Introduction The USB 3.0 to SATA 3.5" Enclosure is designed to support USB equipped computers. This enclosure provides large capacity mobile storage using
Type 2 Tag Operation Specification. Technical Specification T2TOP 1.1 NFC Forum TM NFCForum-TS-Type-2-Tag_1.1 2011-05-31
Type 2 Tag Operation Specification Technical Specification T2TOP 1.1 NFC Forum TM NFCForum-TS-Type-2-Tag_1.1 2011-05-31 RESTRICTIONS ON USE This specification is copyright 2005-2011 by the NFC Forum, and
Technical Support Bulletin Nr.18 Modbus Tips
Technical Support Bulletin Nr.18 Modbus Tips Contents! Definitions! Implemented commands! Examples of commands or frames! Calculating the logical area! Reading a signed variable! Example of commands supported
Network Monitoring. SAN Discovery and Topology Mapping. Device Discovery. Send documentation comments to mdsfeedback-doc@cisco.
CHAPTER 57 The primary purpose of Fabric Manager is to manage the network. In particular, SAN discovery and network monitoring are two of its key network management capabilities. This chapter contains
12Gb/s Intel RAID Controllers User Guide. Intel Order Number: H21668-003
12Gb/s Intel RAID Controllers User Guide Intel Order Number: H21668-003 DISCLAIMER IINFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL
QuickSpecs. What's New Dual Port SFF 10K and 15K SAS drives Dual Port 3.5" 15K SAS drives. HP SAS Drives (Servers) Overview
Overview Serial Attached SCSI is the logical evolution of SCSI, including its long-established software advantage and the Serial ATA electrical and physical connection interface. With enterprise storage
Monitoring the Network
CHAPTER 8 This chapter describes how the DCNM-SAN manages the network. In particular, SAN discovery and network monitoring are two of its key network management capabilities. This chapter contains the
Modbus Protocol. PDF format version of the MODBUS Protocol. http://www.http://www.modicon.com/techpubs/toc7.html. The original was found at:
Modbus Protocol PDF format version of the MODBUS Protocol The original was found at: http://www.http://www.modicon.com/techpubs/toc7.html (In case of any discrepancies, that version should be considered
MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS
MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS 1 Introduction... 2 1.1 Scope of this document... 2 2 Abbreviations... 2 3 Context... 3 4 General description... 3 4.1 Protocol description...
Serial ATA and Serial Attached SCSI technologies
Serial ATA and Serial Attached SCSI technologies technology brief Abstract... 2 Introduction... 2 Serial architecture: the future of HDD technologies... 2 Parallel ATA technology... 2 Parallel SCSI...
SCSI Commands Reference Manual
SCSI Commands Reference Manual Parallel SCSI Fibre Channel (FC) Serial Attached SCSI (SAS) Rev. A SCSI Commands Reference Manual Parallel SCSI Fibre Channel (FC) Serial Attached SCSI (SAS) Rev. A 2006,
The Evolution of Solid State Storage in Enterprise Servers
The Evolution of Solid State Storage in Enterprise Servers Title Subhead: 14/16 Myriad Pro Regular Network inefficiency is a critical issue for today s virtualized datacenters. This paper examines the
QuickSpecs. Models HP Smart Array E200 Controller. Upgrade Options Cache Upgrade. Overview
Overview The HP Smart Array E200 is HP's first entry level PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controller. The full size card has 8 ports and utilizes DDR1-266 memory. The E200 is ideal
RS-485 Protocol Manual
RS-485 Protocol Manual Revision: 1.0 January 11, 2000 RS-485 Protocol Guidelines and Description Page i Table of Contents 1.0 COMMUNICATIONS BUS OVERVIEW... 1 2.0 DESIGN GUIDELINES... 1 2.1 Hardware Design
Intel RAID Controller SASMF8I Hardware User s Guide. Intel Order Number: E33625-003
Intel RAID Controller SASMF8I Hardware User s Guide Intel Order Number: E33625-003 DISCLAIMER INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL(R) PROD- UCTS. NO LICENSE, EXPRESS OR IMPLIED,
SCSI Commands Reference Manual
Product Manual SCSI Commands Reference Manual Parallel SCSI Fibre Channel (FC) Serial Attached SCSI (SAS) 100293068 Rev. C April 2010 2010 Seagate Technology LLC. All rights reserved. Publication number:
SAN Conceptual and Design Basics
TECHNICAL NOTE VMware Infrastructure 3 SAN Conceptual and Design Basics VMware ESX Server can be used in conjunction with a SAN (storage area network), a specialized high speed network that connects computer
ATTO ExpressSAS SAS/SATA Host Adapter Troubleshooting Guide
ATTO ExpressSAS SAS/SATA Host Adapter Troubleshooting Guide 1 5 5 C r o s s P o i n t P a r k w a y A m h e r s t, N Y 1 4 0 6 8 P. 7 1 6. 6 9 1. 1 9 9 9 F. 7 1 6. 6 9 1. 9 3 5 3 w w w. a t t o t e c h.
3 Address Spaces & Transaction Routing. The Previous Chapter. This Chapter. The Next Chapter
PCIEX.book Page 105 Tuesday, August 5, 2003 4:22 PM 3 Address Spaces & Transaction Routing The Previous Chapter The previous chapter introduced the PCI Express data transfer protocol. It described the
HP SATA/SAS hard drive and Solid State Drive installation
HP SATA/SAS hard drive and Solid State Drive installation This document describes how to install Serial ATA (SATA) and Serial Attached SCSI (SAS) hard drives or Solid State Drives (SSD) in an internal
1-Port R422/485 Serial PCIe Card
1-Port R422/485 Serial PCIe Card Installation Guide 1. Introduction Thank you for purchasing this 1-Port RS422/485 Serial PCI Express (PCIe) Card. It is a universal add in card that connects to a PC or
LifeSize Networker Installation Guide
LifeSize Networker Installation Guide November 2008 Copyright Notice 2006-2008 LifeSize Communications Inc, and its licensors. All rights reserved. LifeSize Communications has made every effort to ensure
Machine control going www - Opportunities and risks when connecting a control system to the Internet
B&R Industrial Automation Corp. 1325 Northmeadow Parkway, S-130 Tel: (770) 772-0400 E-mail: [email protected] Roswell, Georgia 30076 Fax: (770) 772-0243 Internet: www.br-automation.com Machine
Technology Note. PCI Express
Technology Note www.euresys.com [email protected] Copyright 2006 Euresys s.a. Belgium. Euresys is registred trademarks of Euresys s.a. Belgium. Other product and company names listed are trademarks or trade
4 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card with HyperDuo SSD Tiering
4 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card with HyperDuo SSD Tiering StarTech ID: PEXSAT34RH The PEXSAT34RH 4-Port PCI Express 2.0 SATA Controller Card with HyperDuo adds 4 AHCI SATA III
6Gb/s MegaRAID SAS RAID Controllers
6Gb/s MegaRAID SAS RAID Controllers User Guide 41450-04, Rev. B 41450-04B Revision History Version and Date Description of Changes 41450-04, Rev. B, Updated the environmental conditions for the RAID controllers.
QuickSpecs. HP Dynamic Smart Array Controllers. Models HP Dynamic Smart Array RAID Controllers. HP Dynamic Smart Array Controllers.
Overview HP Dynamic Smart Array is a RAID solution combining a storage host bus adapter (HBA) and proprietary software components. Eliminating most of the hardware RAID controller components and relocating
PCI Express Overview. And, by the way, they need to do it in less time.
PCI Express Overview Introduction This paper is intended to introduce design engineers, system architects and business managers to the PCI Express protocol and how this interconnect technology fits into
MBP_MSTR: Modbus Plus Master 12
Unity Pro MBP_MSTR 33002527 07/2011 MBP_MSTR: Modbus Plus Master 12 Introduction This chapter describes the MBP_MSTR block. What s in this Chapter? This chapter contains the following topics: Topic Page
Follow these steps to prepare the module and evaluation board for testing.
2 Getting Started 2.1. Hardware Installation Procedure Follow these steps to prepare the module and evaluation board for testing. STEP1: Plug the EG-SR-7100A module into the sockets on the test board.
In-Vehicle Networking
In-Vehicle Networking SAE Network classification Class A networks Low Speed (
NetApp E-Series Storage Systems
NetApp E-Series Storage Systems Hardware Cabling Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277
USB 3.0 Hub + Gigabit Ethernet. Docking Station
USB 3.0 Hub + Gigabit Ethernet Docking Station User Manual Ver. 1.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction...
QuickSpecs. Models. HP StorageWorks Modular Smart Array 50 Enclosure. HP StorageWorks Modular Smart Array 50 Enclosure. Overview
Overview The MSA50 is a 1U Serial Attach SCSI(SAS) disk drive storage enclosure supporting Small Form Factor(SFF) SAS or Serial ATA(SATA) drives. This enclosure delivers industry-leading data performance,
ISO11783 a Standardized Tractor Implement Interface
ISO a ized Tractor Implement Interface Peter Fellmeth, Vector Informatik GmbH The upcoming ISO standard will be the preferred tractor Implement interface in the agricultural industry. Therefore the ISO
NB3H5150 I2C Programming Guide. I2C/SMBus Custom Configuration Application Note
NB3H550 I2C Programming Guide I2C/SMBus Custom Configuration Application Note 3/4/206 Table of Contents Introduction... 3 Overview Process of Configuring NB3H550 via I2C/SMBus... 3 Standard I2C Communication
LonManager PCC-10 and ISA Protocol Analyzers Models 33100-00 and 33100-10
LonManager and Protocol Analyzers Models 33100-00 and 33100-10 Description The LonManager Protocol Analyzer provides LONWORKS manufacturers, system integrators, and end-users with a rich set of Windows
MegaRAID 6Gb/s SAS RAID Controllers
MegaRAID 6Gb/s SAS RAID Controllers User Guide 41450-02, Revision D, June 2010 41450-02D Revision History Version and Date Description of Changes 41450-02 Rev. D, June 2010 Added the SAS 9260-16i, SAS
Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router iscsi Appliance
Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router April 12, 2012 Table of Contents 1.0 Introduction... 4 2.0 Chelsio Unified Storage Router (USR) SAS-to-...
SD Specifications Part A2 SD Host Controller Simplified Specification
SD Specifications Part A2 SD Host Controller Simplified Specification Version 2.00 February 8, 2007 Technical Committee SD Association Revision History Date Version Changes compared to previous issue April
760 Veterans Circle, Warminster, PA 18974 215-956-1200. Technical Proposal. Submitted by: ACT/Technico 760 Veterans Circle Warminster, PA 18974.
760 Veterans Circle, Warminster, PA 18974 215-956-1200 Technical Proposal Submitted by: ACT/Technico 760 Veterans Circle Warminster, PA 18974 for Conduction Cooled NAS Revision 4/3/07 CC/RAIDStor: Conduction
Network Layers. CSC358 - Introduction to Computer Networks
Network Layers Goal Understand how application processes set up a connection and exchange messages. Understand how addresses are determined Data Exchange Between Application Processes TCP Connection-Setup
Serial ATA 2 Ports PCI Host
Serial ATA 2 Ports PCI Host This Manual is for the various Model of 2ports SATA HBA: Model A: Low Profile Serial ATA Internal 2 Ports Model B: Low Profile External 1 Port + Internal 1 Port Model C: Low
What communication protocols are used to discover Tesira servers on a network?
Understanding device discovery methods in Tesira OBJECTIVES In this application note, basic networking concepts will be summarized to better understand how Tesira servers are discovered over networks.
Domain Name System (DNS) Services
12 Domain Name System (DNS) Services Contents Overview..................................................... 12-3 Host and Domain Names.................................... 12-3 Host Tables...............................................
Modicon Modbus Protocol Reference Guide. PI MBUS 300 Rev. J
Modicon Modbus Protocol Reference Guide PI MBUS 300 Rev. J 1 Modicon Modbus Protocol Reference Guide PI MBUS 300 Rev. J June 1996 MODICON, Inc., Industrial Automation Systems One High Street North Andover,
1 Attack Top Attackers Report, Top Targets Report, Top Protocol Used by Attack Report, Top Attacks Report, Top Internal Attackers Report, Top External Attackers Report, Top Internal Targets Report, Top
CX-Supervisor CX-MODBUS TCP
CX-Supervisor CX-MODBUS TCP Getting Started Guide!! PNSPO! . Specifications.. Introduction is an activex intended to work with Cx-Supervisor to enable communication with Modbus TCP server..2. Supported
SAS-2 Integrated RAID Configuration Utility (SAS2IRCU)
SAS-2 Integrated RAID Configuration Utility (SAS2IRCU) User Guide Version 1.1 DB15-000933-01 Revision History Version and Date Description of Changes Version 1.1, Added information about new commands DELETEVOLUME,
Intel RAID Expander Card RES3TV360 Hardware User's Guide. Intel Order Number: H40805-002
Intel RAID Expander Card RES3TV360 Hardware User's Guide Intel Order Number: H40805-002 DISCLAIMER IINFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
Standard of the Camera & Imaging Products Association. White Paper. of CIPA DC-005-2005. Picture Transfer Protocol over TCP/IP networks
Standard of the Camera & Imaging Products Association White Paper of CA DC-005-2005 Picture Transfer Protocol over / networks 8. November. 2005 Published by Camera & Imaging Products Association (portions
USB 2.0 to SATA/IDE Quick Installation Guide
USB 2.0 to SATA/IDE Quick Installation Guide Introducing the USB 2.0 to SATA/IDE The USB 2.0 to SATA/IDE allows you to connect a barebone SATA/IDE disk drive through a USB port. Features and Benefits Fully
4 Port PCIe 2.0 SATA III 6Gbps RAID Controller
4 Port PCIe 2.0 SATA III 6Gbps RAID Controller PEXSAT34SFF *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario
Suppliers' Information Note. Broadcast Access: 140MBit/s. Service and Interface Description
SIN 473 Issue 2.1 December 2014 Suppliers' Information Note For The BT Network Broadcast Access: 140MBit/s Service and Interface Description Each SIN is the copyright of British Telecommunications plc.
! encor en etworks TM
! encor en etworks TM Version A, March 2010 2013 Encore Networks, Inc. All rights reserved. Configuring the BANDIT III s T1 E1 Card for a PCM Voice Network The T1 E1 card fits into the expansion slot on
SATA and SAS Hard Drive Backplane
SATSASBAY3BK Instruction Manual SATA and SAS Hard Drive Backplane 3 Drive 3.5 Removable SATA/SAS Mobile Rack Backplane FCC Compliance Statement This equipment has been tested and found to comply with the
QuickSpecs. Models. HP Dynamic Smart Array B320i Controller. Overview
Overview HP Dynamic Smart array provides more customer choice with higher levels of data protection for embedded controllers, these data protection levels were earlier only available to standup controllers.
PCI Express Basics Ravi Budruk Senior Staff Engineer and Partner MindShare, Inc.
PCI Express Basics Ravi Budruk Senior Staff Engineer and Partner MindShare, Inc. Copyright 2007, PCI-SIG, All Rights Reserved 1 PCI Express Introduction PCI Express architecture is a high performance,
N_Port ID Virtualization
A Detailed Review Abstract This white paper provides a consolidated study on the (NPIV) feature and usage in different platforms and on NPIV integration with the EMC PowerPath on AIX platform. February
Local Interconnect Network Training. Local Interconnect Network Training. Overview
Overview Local Interconnect Network Training History and introduction Technical features The ISO/OSI reference model and LIN Frames Message Frames Communication concept of LIN Command Frames and Extended
AN1304. NFC Type MIFARE Classic Tag Operation. Application note PUBLIC. Rev. 1.3 2 October 2012 130413. Document information
NFC Type MIFARE Classic Tag Operation Document information Info Content Keywords NDEF, NDEF data mapping, NDEF Data Exchange Format MIFARE Classic 1K, MIFARE Classic 4K, MIFARE Classic 1K/4K, MIFARE Plus
PCI SATA Controller Card Model: SY-PCI40010
SY-PCI40010 1 PCI SATA Controller Card Model: SY-PCI40010 User Manual Ver. 2.00 Chipset: Silicon Image SIL3124 SY-PCI40010 2 Product Introduction The Silicon Image Sil3124 Serial ATA I/II to PCI-X32/64-bit
MN-700 Base Station Configuration Guide
MN-700 Base Station Configuration Guide Contents pen the Base Station Management Tool...3 Log ff the Base Station Management Tool...3 Navigate the Base Station Management Tool...4 Current Base Station
How To Configure Voice Vlan On An Ip Phone
1 VLAN (Virtual Local Area Network) is used to logically divide a physical network into several broadcast domains. VLAN membership can be configured through software instead of physically relocating devices
An Analysis of Wireless Device Implementations on Universal Serial Bus
An Analysis of Wireless Device Implementations on Universal Serial Bus 6/3/97 Abstract Universal Serial Bus (USB) is a new personal computer (PC) interconnect that can support simultaneous attachment of
Models 300GB SAS 15K rpm 6Gb/s 3.5" HDD HP 900GB SAS 10K SFF HDD HP 1.2TB SAS 10K SFF HDD
Overview Introduction HP SAS (Serial Attached SCSI) HDDs (Hard Drives) are high-performance, enterprise class hard drives, which are alternative to SATA hard drives. SAS hard drives combine faster data
Use Domain Name System and IP Version 6
Use Domain Name System and IP Version 6 What You Will Learn The introduction of IP Version 6 (IPv6) into an enterprise environment requires some changes both in the provisioned Domain Name System (DNS)
HP StorageWorks MSL2024, MSL4048, and MSL8096 Tape Libraries and 1/8 G2 Autoloader Ultrium 1760 tape drive firmware release notes
HP StorageWorks MSL2024, MSL4048, and MSL8096 Tape Libraries and 1/8 G2 Autoloader Ultrium 1760 tape drive firmware release notes Parallel SCSI version W51W and SAS version U51W Part number: AK378-96023
How To Use An Hp Smart Array P212 (Sas) With A 1-Year Warranty On A 2 Terabyte Hard Drive (Sata) And A 1 Terabyte (Sasa) Hard Drive With A 2-Year License (S
Overview The HP Smart Array P212 is HP's entry level PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controller. The low profile, half height card has 8 ports and utilizes DDR2-800 memory. The P212
ATTO ExpressSAS Troubleshooting Guide for Windows
ATTO ExpressSAS Troubleshooting Guide for Windows This document describes troubleshooting techniques that can be used to identify and resolve issues associated with the ATTO ExpressSAS Raid Controller.
Chapter 5 Customizing Your Network Settings
Chapter 5 Customizing Your Network Settings This chapter describes how to configure advanced networking features of the RangeMax NEXT Wireless Router WNR834B, including LAN, WAN, and routing settings.
Subnetting,Supernetting, VLSM & CIDR
Subnetting,Supernetting, VLSM & CIDR WHAT - IP Address Unique 32 or 128 bit Binary, used to identify a system on a Network or Internet. Network Portion Host Portion CLASSFULL ADDRESSING IP address space