1 Product presentation Milos Dvorak Product manager CZELS PPMV Instrument transformers ABB s.r.o. -1
2 General information General information Instrument transformers Current transformers Current transformers Voltage transformers Voltage transformers Outdoor transformers Outdoor transformers Sensors Application, arguments Application, arguments ABB s.r.o. -2
3 R L ABB CZELS Instrument transformers Electric values (currents and voltages) in power supply systems are extensive. This is why it is necessary to match the respective currents and voltages to those values which shall be appropriate to the connected measuring, protection and control instrument. MV Instrument transformers are used for current and voltage measurements insulation level from 0,72 kv to 40,5 kv both indoor and outdoor use The transformers comply with IEC, DIN, BS, GOST, AS and other standards or with customer specific requirements. ABB s.r.o. -3
4 Instrument transformers - product focus ABB Poland GFFF- LV IEC ABB USA GFFF - ANSI ABB Czech Republic GFFF- MV IEC ABB s.r.o. -4
5 Czech Republic country in the heart of Europe Area: 78,864 km 2 Shares borders with Germany, Poland, Austria, Slovakia Length of state border: 2,303 km Largest cities: Prague, Brno, Ostrava ABB s.r.o. -5
6 Instrument transformers history 1887 Foundation of factory 1919 Production of instrument transformers with oil insulation 1952 Production of instrument transformers with epoxy insulation 1983 Technology of automatic pressured gelation (APG) implemented % of shares was purchased by Asea Brown Boveri Ltd New production plant erected, new production technology and testing equipment 2002 CZELS was appointed as Global focused feeder factory (GFFF) for both indoor and outdoor MV Instrument transformers up to 40,5 kv 2003 CZELS was appointed as Global focused feeder factory (GFFF) for MV Instrument transformers ABB s.r.o. -6 responsibility worldwide
7 Inductive Instrument transformers Current indoor TPU xx.xx post type 3,6kV - 40,5 kv Special application 3,6kV - 40,5 kv Inductive ITs Current outdoor TPO xx.xx supporting 3,6kV - 40,5 kv Voltage outdoor TJO x single pole TDO x double pole 3,6kV - 40,5 kv Voltage indoor TJC x single pole TDC x double pole 3,6kV - 40,5 kv TJP x single pole with fuse 3,6kV - 40,5 kv ABB s.r.o. -7
8 Electronic Instrument transformers (Sensors) Voltage sensors resistive or capacitive divider Electronic instrument transformers Combi sensors Current sensors Rogowski coil General application with REF_ OEM,.. ABB s.r.o. -8 Special application to ABB switchgear or apparatus
9 Instrument transformers according to IEC standards IEC Current transformers IEC Inductive voltage transformers IEC Combined transformers IEC Capacitor voltage transformers IEC Protective current transformers for transient performance IEC Electronic voltage transformers IEC Electronic current transformers ABB s.r.o. -9 IEC TC 38 - discussion to change structure of ITs norms
10 General information General information Instrument transformers Current transformers Current transformers Voltage transformers Voltage transformers Outdoor transformers Outdoor transformers Sensors ABB s.r.o. -10 Application, arguments Application, arguments
11 Current Transformers Wide range of types fits to many various applications El. ratings provided as per individual client s needs. Electrical standards IEC, DIN, BS, GOST, AS. Many metrology certificates & approvals available. ABB s.r.o. -11 Un.. 40,5 kv In A Ithn (1s) ka
12 Product Overview - Indoor Current ITs Support (post) type CTs TPU 4x.xx...up to 12 kv TPU 5x.xx...up to 17,5 kv TPU 6x.xx...up to 24 kv TPU 7x.xx...up to 36 kv - 40,5 kv Bar primary bushing type CTs TTR 4x.xx... up to 12 kv TTR 6x.xx. up to 24kV Bus type CTs KOKS.. up to 17,5 kv KOKS.up to 24 kv Cable ring core LV type for MV application KOLMA, KOLA.0,72 kv (in PLZWA) Main line CTs ABB s.r.o. -12 Special CTs IP 24..for circuit breaker (in PLZWA) KOLT.for power transformers (in PLZWA)
13 Technical Information MV CTs Current transformers (CT) ratings, wide range of application Primary (rated) currents 10 A up to 8000 A (In according to CT type) Secondary currents.1a, 2 A, 5 A Frequency 50 or 60 Hz Rated short-time thermal current I thn (1sec.) 4;6.3;8;12;16;20;25;31.5;40;50;63;80;100 ka Highest voltage for equipment up to 40.5 kv (1min kv, BIL kV) Accuracy: measuring winding:0.1; 0.2; 0.2S; 0.5; 0.5S; 1; 3 factor security (FS): 5;10 protective winding: 5P;10P;. over current factor : 5;10;15;20 special classes PX (IEC ) - U K, R CT, I k Indoor or outdoor dry type, cast resin insulated, up to 6 secondary windings Secondary or primary reconnectable versions Electrical standards IEC, DIN, BS, GOST, AS, etc.available ABB s.r.o. -13
14 Inductive Current transformer PRIMARY TERMINAL P2 P1 EPOXY RESIN PRIMARY WINDING CROSS-SECTION according to short current Ith (ka) LENGTH of the core according to burden (VA) SECONDARY TERMINAL ABB s.r.o. -14 METERING CORE CLASSES 0,2S 0,2 0,5S 0,5 PROTECTIVE CORE CLASSES 5P10 5P15 5P20 10P10 10P15 10P20
15 Current transformers TPU xx.xx - 3,6 25kV Support (post) type current transformer for MV applications, indoor type Definition: A current transformer so arranged that it acts as a support for the conductor in the primary circuit Transformer type TPU 4x.xx TPU 5x.xx TPU 6x.xx Highest voltage for equipment Power frequency test voltage Lighting impuls test voltage kv 3,6 7, ,8 17, kv up to 28 kv up to 42 kv up to 55 kv kv up to 75 kv up to 95 kv up to 125 kv Primary current A 10 A-3200 A 10 A-3200 A 10 A-3200 A Rated short time thermal current ka- 1sec 4 ka 100 ka 4 ka 100 ka 4 ka 100 ka Burden, classes VA/ cl 5-30/0, /5P..10P /0, /5P..10P /0, /5P.10P. Secondary terminals 12 terminals (max. 6sec.) 12 terminals (max. 6sec.) 12 terminals (max. 6sec.) Dimensional standard DIN (148mm) wide(184mm) DIN (148mm) wide(184mm) DIN (178mm) Electrical standards Reconnectable (primary A) IEC, DIN, BS, GOST,ANSI, IEC, DIN, BS, GOST,ANSI, IEC, DIN, BS, GOST, ANSI, prim. or sec. prim. or sec. prim. or sec. ABB s.r.o. -15 without ribs with ribs
16 Current transformers TPU xx.xx ,5 kv Support (post) type current transformer for MV applications, indoor type Definition: A current transformer so arranged that it acts as a support for the conductor in the primary circuit Transformer type TPU 7x.5x, TPU 7x.6x Highest voltage for equipment kv 36 38,5 40,5 Power frequency test voltage, 1 min. Lighting impuls test voltage (BIL) kv max 95 kv max 200 Primary current A 10 A 2500 A Rated short time thermal current ka (1sec) 4 ka 100 ka Burden, classes VA, cl 5-30/0, /5P..-10P.. Secondary terminals 12 terminals. max. 6 sec. Dimensional standard Non standard Electrical standards IEC, DIN, BS, GOST, ANSI,.. ABB s.r.o. -16 TPU 7x.5x TPU 7x.6x Reconnectable (primary till A) prim. or sec.
17 Current transformers TTR xx.xx - 3,6 25kV Bar primary bushing type current transformer for MV applications, indoor Definition: A current transformer with bar primary conductor so constructed that it can be used as a bushing Transformer type TTR 4x.xx TTR 6x.xx Highest voltage for equipment kv 3,6 7, , Power frequency test voltage, 1 min. Lighting impuls test voltage (BIL) kv max 28 max 55 kv max 75 max 125 Primary current A 100, 200, 300, 400, 500, 600, 750, 1000,1250, 1500, 2000, 2500 Rated short time thermal current ka (1sec) Burden, classes VA, cl 5-30/0, /5P..-10P.. Secondary terminals 4 terminals. max. 2 sec. Dimensional standard Non standard Electrical standards IEC, DIN, BS, GOST, ANSI,.. Reconnectable Secondary 1 winding only ABB s.r.o. -17 TTR 6x.xx
18 Current transformers BB - 3,6 25 kv Bushing type current transformer for MV applications, indoor Definition: A current transformer without primary conductor, but with primary insulation of its own which can be used as a bushing Transformer type BB 103 BB 104 (BBO) BB 223 Highest voltage for equipment kv 3,6 7,2 12 3,6 7, , Power frequency test volt. 1 min. kv up to 28 kv up to 28 kv up to 55 kv Lighting impuls test voltage (BIL) kv up to 75 kv up to 75 kv up to 125 kv Primary current A max 4000 A max 5000 A max 4000 A Rated short time thermal current ka (1sec) Burden, classes VA, cl 5-60/0, /5P..- 10P.. Secondary terminals 4 terminals (max. 2 sec.) max 63 max 63 max /0, /5P..- 10P.. 6 terminals (max. 3 sec.) 5-60/0, /5P..- 10P.. 4 terminals (max. 2 sec.) Dimensional standard Electrical standards Non standard IEC, DIN, BS, GOST, ANSI,.. Non standard IEC, DIN, BS, GOST, ANSI,.. Non standard IEC, DIN, BS, GOST, ANSI,.. Reconnectable secondary secondary secondary ABB s.r.o. -18
19 Current transformers KOKS - 3,6 24 kv Bus type current transformer for MV applications, indoor Definition: A current transformer without primary conductor, but with primary insulation, which can be fitted directly over a conductor or busbar Transformer type KOKS 12 KOKS 17,5 KOKS 24 Highest voltage for equipment kv 12 17,5 up to 24 Power frequency test voltage, 1 min. kv max 50 Lighting impuls test voltage (BIL) kv max 125 Primary current A 1000, 1250, 1500, 2000, 3000, 4000, (5000, 6000, 7000, 8000-KOKS 24 only) Rated short time thermal current ka (1sec) up to 100xIn Burden, classes VA, cl 5-30/0, /5P..-10P.. Secondary terminals 8 terminals. max. 4 sec. Dimensional standard Non standard Electrical standards IEC, DIN, BS, GOST, ANSI,.. ABB s.r.o. -19 KOKS 12 KOKS 17,5 KOKS 24 Reconnectable Secondary
20 LV Cable Current Transformers for MV applicatin (in PLZWA) WINDOW TYPE Voltage system 0.72 kv Rated primary current: I pn = 50 up to 2000 A Rated secondary current: I sn = 1 or 5 A type KOKM 06 J Mainly for protection (10P; 5P) Number of cores: 1 Window size 300 x 200 mm 650 x 450 mm ABB s.r.o. -20 KOKM / KOLA / KOLMA For medium voltage systems Wide range of products (standard and customer s designed) Indoor application Intended for ABB and OEM s MV panels For AIS and GIS
21 Cable current transformers KOKM/KOKU (in PLZWA) KOKM indoor type KOKU outdoor type CUSTOMER DESIGNED Voltage system 1.2 kv Rated primary current: I pn = up to A Rated secondary current: I sn = 1 or 5 A All accuracy classes for measurement and protection Number of cores: up to 4; ID mm ABB s.r.o. -21
22 LV Instrument transformers special applications (in PLZWA) New designed products For power transformers (KOLT); full range of products (cast resin and uncasted ) KOLT without casting KOMSH epoxy cast resin Voltage system 1.2 kv Rated primary current:i pn = up to A Rated secondary current: I sn = 1 or 5 A For protection and measurement Number of cores: up to 6; ID mm ABB s.r.o. -22
23 General information General information Instrument transformers Current transformers Current transformers Voltage transformers Voltage transformers Outdoor transformers Outdoor transformers Sensors ABB s.r.o. -23 Application, arguments Application, arguments
24 Voltage Transformers For fixed and withdrawable solutions Single and double pole versions Special types for supply of aux. power. Electrical standards IEC, DIN, BS, GOST, AS. Un.. 40,5 kv Pn VA.. 3 secondaries Many metrology certificates & approvals available. ABB s.r.o. -24
25 Product Overview - Indoor Voltage ITs Single pole insulated VTs TJC 4... up to 12 kv TJC 5... up to 17,5 kv TJC 6... up to 24 kv TJC 7 or 7.1..up to 36 kv - 40,5 kv Single pole insulated VTs with fuses TJP 4.x... up to 12 kv TJP 5.x... up to 17,5 kv TJP 6.x... up to 24 kv TJP 7.1 or 7.2..up to 36 kv - 40,5 kv Main line VTs ABB s.r.o. -25 Double pole insulated VTs TDC 4... up to 12 kv TDC 5... up to 17,5 kv TDC 6... up to 24 kv TDC 7..up to 36 kv
26 Technical Information MV VTs Voltage transformers (VT) ratings, wide range of application Main primary (rated) voltages Un..3;6;10;15;20;30;33;35kV (phase to earth Un/V3) Secondary voltages...100;110;100/ 3;110/ 3;100/3;110/3 V Frequency 50 or 60 Hz Highest voltage for equipment 3.6 kv up to 40.5 kv(1min kv, BIL kV) Accuracy class: measuring winding 0.1;0.2;0.5;1 protective winding 3P;6P auxiliary winding 6P Indoor or outdoor dry type, cast resin insulated, up to 3 secondary windings Secondary reconnectable versions Electrical standards IEC, DIN, BS, GOST, AS, etc.available ABB s.r.o. -26
27 Inductive Voltage transformer PRIMARY TERMINAL A EPOXY RESIN PRIMARY COIL SECONDARY COIL MAGNETIC CORE SECONDARY TERMINAL ABB s.r.o. -27 CROSS-SECTION of the core -important for max. nominal burden (VA) and classes 0,2, 0,5 1 3P 6P
28 Inductive Voltage transformer PRIMARY TERMINALS EPOXY RESIN A B PRIMARY COILS SECONDARY COIL MAGNETIC CORE SECONDARY TERMINAL ABB s.r.o. -28 CROSS-SECTION of the core -important for max. nominal burden (VA) and classes 0,2, 0,5 1 3P 6P
29 Voltage transformers TJC x,tjp x.x - 3,6 25kV Earthed voltage transformer (single pole or one pole insulated) for MV applications, indoor type Transformer type without fuse with fuse holder Highest voltage for equipment TJC 4 TJP 4.x kv 3,6 7,2 12 Rated voltage kv 3/V3 6/V3 10/V3 TJC 5 TJP 5.x TJC 6 TJP 6.x 13,8 17, /V3 15/V3 20/V3 22/V3 Definition: A single phase voltage transformer which is intended to have one end of its primary winding directly earthed Power frequency test voltage, 1 min. Lighting impuls test voltage (BIL) Max. rated burden/classes Residual winding kv up to 28 up to 38 up to 50 kv up to 75 up to 95 up to 125 VA, cl VA, cl 20/0,2 50/0,5 100/ /6P 20/0,2 50/0,5 100/ /6P 30/0,2 75/0,5 120/ /6P Secondary winding Dimensional standard DIN DIN DIN Electrical standards IEC,BS, GOST,.. IEC,BS, GOST,.. IEC,BS, GOST,.. ABB s.r.o. -29 TJP 4.1 TJC 6
30 Voltage transformers TJC x, TJP x.x ,5 kv Earthed voltage transformer (single pole or one pole insulated) for MV applications, indoor type Definition: A single phase voltage transformer which is intended to have one end of its primary winding directly earthed Transformer type TJC 7 TJC 7.1 Highest voltage for equipment kv 36 38,5 40,5 Rated voltage kv 30/V3,33/V3 35/V3 Power frequency test voltage, 1 min. Lighting impuls test voltage (BIL) TJP 7.1 TJP ,5 30/V3,33/V3 35/V3 kv max 95 max 80 kv max 200 max 180 Max. rated burden/classes VA, cl 50/0,2 150/0,5 250/1 30/0,2 75/0,5 150/1 Residual winding VA, cl /6P /6P Secondary winding 2 2 Dimensional standard non standard non standard ABB s.r.o. -30 TJC 7 TJP 7.1 Electrical standards IEC,BS, GOST,.. IEC,BS, GOST,..
31 Voltage transformers TDC x - 3,6 25kV Unearthed voltage transformer (double pole or two pole insulated) for MV applications, indoor type Definition: A voltage transformer which has all parts of its primary winding, including terminals, insulated from the earth at a level corresponding to its rated insulation level Transformer type TDC 4 TDC 5 TDC 6 Highest voltage for equipment kv 3,6 7, ,8 17, Rated voltage kv Power frequency test voltage, 1 min. Lighting impuls test voltage (BIL) Max. rated burden/classes kv up to 28 up to 38 up to 50 kv up to 75 up to 95 up to 125 VA, cl 20/0,2 50/0,5 100/1 20/0,2 50/0,5 100/1 30/0,2 75/0,5 120/1 Secondary winding Dimensional standard DIN DIN DIN Electrical standards IEC,BS, GOST,.. IEC,BS, GOST,.. IEC,BS, GOST,.. ABB s.r.o. -31 TDC 6
32 Voltage transformers TDC x, KGUG ,5 kv Unearthed voltage transformer (double pole or two pole insulated transformer) for MV applications Definition: A voltage transformer which has all parts of its primary winding, including terminals, insulated from the earth at a level corresponding to its rated insulation level Transformer type TDC 7 KGUG Highest voltage for equipment kv 36 40, Rated voltage kv Power frequency test voltage, 1 min. Lighting impuls test voltage (BIL) Max. rated burden/classes kv max 80 up to 70 kv kv max 180 up to 170 kv VA, cl 50/0,2 150/0,5 250/1 80/0,2 300/0,5 600/1 Secondary winding 2 secondary w. 2 secondary w. Dimensional standard no no Electrical standards IEC,BS,GOST,.. IEC,BS,GOST,.. ABB s.r.o. -32 TDC 7 KGUG
33 General information General information Instrument transformers Current transformers Current transformers Voltage transformers Voltage transformers Outdoor transformers Outdoor transformers Sensors ABB s.r.o. -33 Application, arguments Application, arguments
34 Outdoor Instrument Transformers Un.. 40,5 kv In A Ithn (1s) ka El. ratings provided as per individual client s needs. Advanced epoxy resin material HCEP VTs single and double pole Electrical standards IEC, DIN, BS, GOST, AS. Many metrology certificates & approvals available. ABB s.r.o. -34
35 Main line outdoor current transformers TPO xx.xx Outdoor current transformer for MV applications Definition: Current transformer which can be used under outdoor service conditions (ambient air temperature, humidity, pollution, ) Transformer type TPO 6x.xx TPO 7x.xx Highest voltage for equipment kv 12 17, ,5 40,5 Power frequency test volt., 1 min. Lighting impuls test voltage (BIL) kv max 55 max 95 kv max 125 max 200 Primary current A 10 A 2500 A Rated short time thermal current ka (1sec) 4 ka 100 ka Burden, classes VA, cl 5-30/0, /5P..-10P.. Secondary terminals 8 terminals. max. 4 sec. Dimensional standard Electrical standards Non standard IEC, DIN, BS, GOST, ANSI,.. Reconnectable (primary till A) prim. or sec. ABB s.r.o. -35 TPO 6x.xx TPO 7x.xx
36 Main line outdoor voltage transformers TJO 6, TDO 6 Outdoor voltage transformers for MV applications Definition: Voltage transformers which can be used under outdoor service conditions (ambient air temperature, humidity, pollution, ) Transf. type-single pole -double pole Highest voltage for equipment Rated voltage single pole double pole Power frequency test voltage, 1 min. Lighting impuls test voltage (BIL) TJO 6 TDO 6 kv 12 17, kv 10/V3, 13,8/V3,15/V3 20/V3 22/V , kv max 55 kv max 125 Max. rated burden/classes VA, cl 50/0,2 150/0,5 250/1 Residual winding (for single polevts only) Secondary terminals VA, cl /6P max. 3 secondaries Dimensional standard Non standard Electrical standards IEC, DIN, BS, GOST, ANSI,.. ABB s.r.o. -36 TDO 6 TJO 6
37 Main line outdoor voltage transformer TJO 7 Outdoor voltage transformer for MV applications Transformer type single pole Highest voltage for equipment TJO 7 kv 36 38,5 40,5 Definition: Voltage transformer which can be used under outdoor service conditions (ambient air temperature, humidity, pollution, ) Rated voltage kv 30/V3 33/V3 35/V3 Power frequency test voltage, 1 min. Lighting impuls test voltage (BIL) kv max 95 kv max 200 Max. rated burden/classes VA, cl 50/0,2 150/0,5 250/1 Residual winding VA, cl /6P Secondary terminals max. 3 secondaries Dimensional standard Non standard Electrical standards IEC, DIN, BS, GOST, ANSI,.. ABB s.r.o. -37
38 General information General information Instrument transformers Current transformers Current transformers Voltage transformers Voltage transformers Outdoor transformers Outdoor transformers Sensors ABB s.r.o. -38 Application, arguments Application, arguments
39 Sensors Electronic instrument transformers KEVCD types easily fit into OEMs panels (DIN42600) Both protection and metering done with one double rated sec. winding Advanced technology for Integrated Solutions! One single standard sensor for wide range of currents and voltages. Comply with IEC ,7,8 (Combi, I, U Sensors) ABB s.r.o. -39 Un.. 24 kv In A Ithn (1s).. 63 ka
40 Sensors Electronic instrument transformers Voltage sensors resistive or capacitive divider Electronic instrument transformers Combi sensors Current sensors Rogowski coil General application with REF_ OEM,.. ABB s.r.o. -40 Special application to ABB switchgear or apparatus
41 Instrument transformers according to IEC standards IEC Current transformers IEC Inductive voltage transformers IEC Combined transformers IEC Capacitor voltage transformers IEC Protective current transformers for transient performance IEC Electronic voltage transformers IEC Electronic current transformers ABB s.r.o. -41 IEC TC 38 - discussion to change structure of ITs norms
42 Related standards to electronic instrument transformers Instr. transformers Switchgear VDS & VPIS IEC IEC IEC IEC Relays IEC Cables IEC IEC ABB s.r.o. -42
43 Sensors Electronic instrument transformers Standards: Primary sensor Primary converter Transm. system Secondary converter Relay ABB sensors: Power supply Power supply U-sensor I-sensor Relay ABB s.r.o. -43
44 Accessories - Adapters Sensor Cable Adapter IED The adapter enables to utilize the full functionality of sensor + relay system. The adapter is adjusting sensor output signal to the level suitable for different applications of IED. ABB s.r.o. -44 The criterion of selection is based on the system current: No adapter: Ir = A Adapter 240A/150mV: Ir = A Adapter 640A/150mV: Ir = A
45 Current Sensors KECA 80 A1 KECA 300 A1 KECA 800 A1 KECR 17,5 AC1 Uniformly wound coil with non-magnetic core Output signal is proportional to the derivate of primary current IEC Nominal primary current KECA 80, 300 or 800 A KECR 180 A Current sensor cl. 1.0 ABB s.r.o. -45
46 Current sensor principle: Rogowski coil ABB s.r.o. -46 u U di M dt = M j ω out = out I p p ABB Rogowski U nominal = 0,150V (50Hz) I nominal = 80A Z input Safe = >4MΩ U output@50ka = 94V P= U 2 /R = 5, W
47 Rated current: KEVCD current range calculation Example: Combination suitable for 200 A, 50 Hz switchgear: Adapter Transm. ratio Us at Ip = 0,05x200 A Ip at Us = 7,5 V No adapter 80 A / 0,150 V 18,8 mv (OK) A (Too small) Adapter A / 0,150 V 6,3 mv (OK) A (OK) Adapter A / 0,150 V 2,3 mv (Too small) A (OK) Sensor I pr = A Adapter REF 542+ : U smax = 7,5 V U smin = 5 mv ABB s.r.o. -47 KEVCD
48 Sensors: Fewer rated currents Current transformers Current sensor 80 A 480 A 1250 A A ABB s.r.o. -48 One single standard sensor can be used for a range of switchgear rating currents.
49 Sensors: Fewer cores Current transformer Multi-purpose sensor Measurement Protection M & P ABB s.r.o. -49 Measurement and protection can be realised with one single secondary winding with double ratings.
50 Technical Information current sensors Current sensors parameters Primary currents 4 A up to 3200 A (according to sensor type) Secondary signal 150 mv 50 HZ 160 mv 60 Hz Rated short-time thermal current I thn (1sec.) 4;6.3;8;12;16;20;25;31.5;40;50kA Highest voltage for equipment 3.6 kv up to 24 kv (1min kv, BIL ) Accuracy classes: measuring or protection: 1;3 (without correction factor) Indoor epoxi resin - KEVCD, KEVCY_RE, KECR, KEVA (or dry type KECA) Different length of cable 5m, 6,5 and 7,5 m for KEVCD, Adaptors for 3 different rated currents (KEVCD) Sensors must be connected to ABB relay only (RE_ family REF, REM, etc.) ABB s.r.o. -50
51 Electronic CTs (sensors) versus Inductive CTs ABB s.r.o. -51 Sensors absence of iron
52 Electronic CTs (sensors) versus Inductive CTs Open secondary (CT) Current transformer Current sensor Uopen Isc 0-10 kv Isc/Acu = 40 ma/mm 2 ABB s.r.o. -52
53 Voltage Sensors (electronic VTs) KEVI 24A1, 24 kv (GIS) Resistive divider Matched resistor pair 1: divider ratio Accuracy up to class 1 KEVA 24A, 24 kv (AIS) Capacitive divider Zc = 1/ωC 1: divider ratio Accuracy up to class 3 Small size ideal for bushings ABB s.r.o. -53
54 Voltage sensor principle: Capacitive divider ABB Capacitive voltage sensor C 1 = 15pF C 2 = 150nF 1: divider ratio Passive element Accuracy up to class 3 Small size ideal for bushings ABB s.r.o. -54 u = C 1 out u p C + 1 C2
55 Voltage sensor principle: Resistive divider ABB Resistive voltage sensor R 1 = 250 MOhm R 2 = 25 kohm 1: divider ratio Divider accuracy up to class 1 Passive element < 10 meters cable ABB s.r.o. -55 u = R 2 out u p R1 + R2
56 Voltage sensors: smaller space needed Voltage transformer Voltage sensor Very small size Very low weight ABB s.r.o. -56
57 Voltage sensors: smaller space needed Voltage transformer Voltage sensor Small volume ABB s.r.o. -57 Low weight
58 Technical Information voltage sensors Voltage sensor parameters Primary voltages Un.. 3;6;10;15;20kV (phase to earth Un/V3) Secondary voltages (signal) according to primary voltage level, ratio always :1 Highest voltage for equipment 3.6 kv up to 24 kv (1min kV, BIL kV) Accuracy class: measuring or protection: 1;3 ;3P 6P; according to the type of voltage divider (better accuracy for resistive divider) Sensors must be connected to ABB relay only (RE_ family REF, REM, etc.) ABB s.r.o. -58
59 Sensors (Electronic VTs) versus Inductive VTs Linearity % ABB s.r.o. -59 Voltage error 8 6 Error limit, class 3P 4 Typical error, voltage sensor Typical error, voltage transformer -8 U/Un %
60 Sensors (Electronic VTs) versus Inductive VTs Short-circuited secondary (VT) Voltage transformer Voltage sensor I sc 15pF 150nF I sc Isc/Acu = 160 A/mm 2 Temp. 500 C Isc = Inormal ABB s.r.o. -60 Explosion within 30 s
61 Combi Sensors (Electronic transformers) The most frequent type KEVCD_AE3 KEVCD_AG3 KEVCD_BE2 KEVCD_BG2 Current and voltage sensors in the same block Measurement and protection by one sensor Dimensions and primary connections same as DIN-type CTs (DIN 42600) 12, 17.5, 24 kv, two types: A. </= 1250 A B. > 1250 A (max A) 24kV, 630A Current sensor (cl 3) Voltage sensor (cl 5) 24kV, 630A Current sensor (cl 3) Voltage sensor (cl 5) ABB s.r.o. -61 KEVCY 24 RE1 KEVCY 24 SA KEVCY 24 SB
62 Combi sensor PRIMARY TERMINAL EPOXY RESIN P2 P1 PRIMARY CONDUCTOR VOLTAGE SENSOR -VOLTAGE DIVIDER SECONDARY OUTLETS ABB BA PTMV s.r.o. -62 Page 27 CURRENT SENSOR -ROGOWSKI COIL
63 Sensors: compactness Current transformer Combined sensor Voltage transformer ABB s.r.o. -63
64 Technical Information combi sensors Combi sensor voltage and current sensors in one block parameters Primary voltages Un.. 3;6;10;15;20kV (phase to earth Un/V3) Highest voltage for equipment 3.6 kv up to 24 kv (1min kV, BIL kV) Primary currents 4 A up to 3200 A (according to sensor type) Sensors must be connected to ABB relay only (RE_ family REF, REM, etc.) ABB s.r.o. -64
65 Electronic ITs(Sensors) versus Inductive ITs Secondary wiring I Instr. transf. Terminal blocks Relay Wiring and screw connections Sensor IED ABB s.r.o. -65 Integrated cable and connector
66 Sensors - advantages Max. secondary signal Safe Secondary wiring Integrated Burden calculations No Short-circuited secondary Safe Open secondary Safe Frequency response Hz Voltage test 50 Hz Yes Remanence No DC-test of cables Yes Ferroresonance No Weight 2-15 kg Standardisation Yes ABB s.r.o. -66 Minimum energy losses reduces the need for cooling aggregates in the switchgear or in the apparatus.
67 Electronic ITs(Sensors) versus Inductive ITs 3 combi sensors 3 CTs and 3 VTs ABB s.r.o. -67
68 Savings in material and installation All you need with sensors is... Sensor / phase Integrated cable and connector (included with sensor) IED ABB s.r.o. -68
69 General information General information Instrument transformers Current transformers Current transformers Voltage transformers Voltage transformers Outdoor transformers Outdoor transformers Sensors ABB s.r.o. -69 Application, arguments Application, arguments
70 Applications of indoor Instrument transformers The instrument transformers are intended for panels and installations of ABB, but also for OEMs, Utilities and the loose market outside ABB. MV ITs in the different business areas: -Air and gas insulated switchgears -AIS primary distribution -AIS secondary distribution -GIS primary distribution -GIS secondary distribution -Railway traction ABB s.r.o. -70 LV ITs in the different business areas: -MV AIS or GIS (on the cable) -LV switchgear
71 Application of outdoor MV Instrument transformers with old PVB with new TPO MV ITs in the different business areas: -Outdoor substation with outdoor CBs disconnectors CTs, VTs -Railway traction both CTs, VTs mainly 27 kv -Overhead line with switches mainly double pole VTs -Generally Replacement of old outdoor ITs worldwide OHB CB, TPO CTs New CTs, old VTs ABB s.r.o. -71
72 Application of electronic transformers-sensors The sensors are intended for panels and installations of ABB, but also (with ABB relays) for OEMs, Utilities and the loose market outside ABB. MV sensors in the different business areas: -Air and gas insulated switchgears -AIS primary distribution (KEVCD) -AIS secondarydistribution (KEVCD) - another apparatus -with indoor CBs ABB s.r.o. -72 Unigear Uniswitch Unimix RMU to OEM with RE_relay
73 Application of electronic transformers-sensors MV sensors in the different business areas: -Air and gas insulated switchgears -AIS primary distribution (KEVCD) -AIS secondarydistribution (KEVCD) -GIS secondary distribution (KEVCY_RE) - another apparatus -with indoor CBs -with SECTOS (KEVCY 24 SA or SB) ABB s.r.o. -73
74 Sales Arguments: certification, experiences, technology Over 50 years of epoxi ITs manufacturing Continues product development program CVT+ calc. program available APG technolology Modern design 1919 Production of ITs with oil insulation Instrument transformers history, Brno, CZ 2003 New production 1952 plant erected ABB.- Foundation of Production of ITs ITs division in CZ with epoxy insulation ABB CZ GFFF Global focused feeder Factory for ITs and sensors Seismic withstand test available Tested and certified according to different standards including GOST Metrology approvals from different countries available DE, CH, PL, SI, HU, SK, RO, RU, UA, LT, LV, BG, BH, etc. ITs fully comply with various customer requirements, DIN design available References in more than 85 countries worldwide, in all continents, more than units in service ABB s.r.o. -74
75 Applications of Electronic ITs (sensors), arguments Over 10 years of sensors manufacturing Continues product development program Modern design Tailor - made Standard KECA_ voltage sensor KEVA_A voltage sensor KEVCY_AE combi sensor KEVCD combi sensor KEVCY_RE combi sensor KEVCY_SA combi sensor KEVCO combi sensor KEVCD_A combi sensor (redesign) KECR current sensor Sensors fully comply with various customer requirements, DIN design available References in more than 35 countries, in all continents, more than units in service ABB s.r.o. -75 Some advantages obtained with the use of sensors: -Savings in material and installation -Losses negligible -Short delivery times. -Linearity over a wide range of current and/or voltage, logistic process is short. -Versatile protection and control solutions. -The sensors are linear up to the highest currents and voltages with a good dynamic performance. - Overvoltage and disturbance withstand. Voltage sensors do not need to be disconnected for voltage testing - They can not cause ferroresonance and are not sensitive to ferroresonance and DC-voltages. - A broken circuit or short-circuit in the signal cable will cause no hazards or damage. -Sensors - savings in project lead times
76 Instrument transformers into OEM panels TPU xx.xx...3,6 up to 36 kv TJC x.. 3,6 up to 36 kv Combi sensor KEVCD xx x...3,6 up to 24 kv TJP x.x... 3,6 up to 36 kv ABB s.r.o. -76 Current and Voltage sensors KECA xx..3,6 up to 24 kv KEVA xx. 3,6 up to 24 kv Low voltage cable CTs KOLA, KOLMA, KOKM (PLZWA) TDC x.. 3,6 up to 36 kv
77 Trend of Instrument transformers in ABB CZEJF pcs ABB s.r.o
78 Export of Instrument transformers NAM WE CEE LAM MENA SEA SSA AU ABB s.r.o. -78 ABB Czech Republic
79 Modern, the newest technology APG technology ABB s.r.o. -79
80 ABB s.r.o. -80
ABB. Presentation 2004. Medium voltage Instrument transformers and Sensors
Presentation 2004 Medium voltage Instrument transformers and Sensors 2003 s.r.o org. unit EJF was appointed by BA PTMV GFFF for MV CTs, VTs and Sensors Instrument transformers history 1887 Foundation of
Medium voltage product. Instrument transformers for indoor applications Product overview
Medium voltage product Instrument transformers for indoor applications Product overview 02 Contents Introduction Current transformers Supporting type 6 TPU, TPE 7 KOFA, IHBF 10 Dummy Bus type 8 KOKS 12,
KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB
KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor Type Cable Current Transformers Index Description... 3 Technical
How To Choose A Transformer
Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV
Vario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
Metal Clad Indoor Instrument Transformer for Plug-In Systems
Metal Clad Indoor Instrument Transformer for Plug-In Systems RITZ Instrument Transformers GmbH Core competency Under the trading name RITZ Instrument Transformers GmbH RITZ has been pooling its activities
Earth Fault Detection Basics in Theory
Earth Fault Detection Basics in Theory Author: Dipl.-Ing. Ingo Kühnen Woodward Power Solutions Krefelder Weg 47 47906 Kempen, Germany Kempen, 16.04.2010 Earth_Fault_Detection_20100416.doc page 1 1. Star
Instrument Transformers Application Guide
Instrument Transformers Application Guide Edited by ABB AB High Voltage Products Department: Marketing & Sales Text: Knut Sjövall, ABB Layout, 3D and images: Mats Findell, ABB SE-771 80 LUDVIKA, Sweden
How To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
LOW-VOLTAGE CURRENT TRANSFORMERS
LOWVOLTAGE CURRENT TRANSFORMERS 5 A Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) 45 75 39; 45 75 305; 45 75 3; 45 75 368; email: [email protected] ul. Słubicka 657 Zielona Góra CONTENTS
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy
Secondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV
1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled
Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy
Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution
UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,
Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation
Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation Index News Introduction Applications & Segments Main Components Applicable Standards Technical characteristics
The standards mentioned in this document
The standards mentioned in this document Where can you order IEC publications? Central Offices of the International Electrotechnical Commission 1, rue de Varembé Geneva - Switzerland. The documentation
2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation
2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation 123 kv Inductive Fingrid (Finland). 18 Instrument transformers igh voltage INTRODUCTION Inductive voltage transformers are designed
CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X
CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD
Medium voltage products. UniGear 500R 17.5 kv, arc-proof, air insulated switchgear for green applications
Medium voltage products UniGear 500R 17.5 kv, arc-proof, air insulated switchgear for green applications 2 Index 4 1. Description 6 2. Air insulated switchgear 10 3. IEC Classification 12 4. Design features
Tape Wound, Split Core and Ebony Current Transformers
Tape Wound, Split Core and Ebony Current Transformers Current Transformers Contents Page Tape Wound Measuring and Protection Current Transformers 2 6 Split Core Current Transformers 7 9 3-in-1 Current
Digital Energy ITI. Instrument Transformer Basic Technical Information and Application
g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER
DS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
Enhanced Quality with a Touch of Style
Rudolf Current Transformer Enhanced Quality with a Touch of Style Current Transformer Enhanced Quality with a Touch of Style New Products Rudolf launched our new encapsulated current transformer. Portraying
Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 [email protected]
CURRENT TRANSFORMER MODEL J " x 7" PAGE No 2-2 REV 8DEC00 TERMINAL OPTION LEAD WIRE OPTION 8-2 BRASS SCREW TERMINALS (2 PLACES) SEE NOTE 9 6 9 8 6 Ø 2 9 (4 PLACES) UL 05 #6 AWG LEAD WIRE, STANDARD LENGTH
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility
Advantages of Fixed Circuit Breaker Switchgear
Advantages of Fixed Circuit Breaker Switchgear by Lionel Mackay, EDF Energy, and Mike Adams, Schneider Electric Ltd Introduction The purpose of this paper is to review the advantages of fixed circuit breaker
Medium-voltage transformers
Medium-voltage transformers We make energy measurable and take care of your future www.mbs-ag.com Page 2 E-Mail: [email protected] Web: www.mbs-ag.com Contents Current transformers Technical characteristics
Current transformers (CT) & Shunts
Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar
Safe and reliable distribution network ABB portfolio for medium-voltage indoor applications
Safe and reliable distribution network ABB portfolio for medium-voltage indoor applications Complete solution for indoor applications ABB s products provides safe, reliable and smart technologies for the
Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy
Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant
Current transformer selection guide
The selection of a current transformer is a simple task. There are four phases in the selection procedure. Current transformer selection guide KEEP IN MIND efine customer requirements based on the primary
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Measurement devices Accessories for analogue and digital instruments
Accessories for analogue and digital instruments 1 2CSC96F0001 Current transformers Used to transform primary currents (max. 6000 A) into.../5 A and.../1 A low secondary currents indirectly supplying power
CAS 36 Ring Main Unit
Power distribution networks Ring Main Unit Catalogue 2008 A new path for achieving your electrical installations A comprehensive offer The range is part of a comprehensive offer of products that are perfectly
(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
The Intelligent AX1 Switchgear for Medium Voltage
The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched
System pro M compact Miniature Circuit Breaker S 200/S 200 M
Data Sheet System pro M compact Miniature Circuit Breaker S 200/S 200 M 2CDC021023S0012 2CDC021038S0012 The miniature circuit breakers of the System pro M compact series S 200 and S 200 M provide state-of-the-art
ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
SF 6 Gas Insulated Switchgear Type SDF for 170 kv
Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDF for 170 kv 06B1-E-0001 With Trustworthy Technology, Structure Fuji Electric as a manufacturer of comprehensive substation equipment
INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002
INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002 NEW GAS INSULATED SWITCHGEAR (GIS) FOR ALL MEDIUM VOLTAGE APPLICATIONS H. Fink, ABB Calor Emag Mittelspannungs GmbH; M. Hyrenbach, ABB Calor
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
BETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
Medium voltage circuit breaker
Medium voltage circuit breaker IEC 60 056 and ANSI C37-06 define on one hand the operating conditions, the rated characteristics, the design and the manufacture; and on the other hand the testing, the
2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1
2013 RESIBLOC transformers Product presentation October 2, 2013 Slide 1 Dry-type transformers For customers with high requirements Does your transformer application requires one of the following characteristic?
Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal. www.takfanmakina.com.tr
www.takfanmakina.com.tr Plug in Bushing LV Monoblock RMU Bushing 4 Way CT Terminal Solution Partner of Medium Voltage Insulation and Epoxy Casting Design *Medium voltage Switching Equipments Design *Load
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
keep your measure under control
INSTRUMENTACIÓN INDUSTRIAL ZURC, S.A. keep your measure under control CURRENT For measuring instruments. Mounted in selfexinguishing, plastic, strengthened cases. Isolation voltage V Made as per UNEEN
Non-extensible circuit breakers
Specification Non-extensile circuit reakers 200A 0 CN2-T1 Indoor / outdoor Normal rated current 200A 12kV 16kA 3 seconds 75kV BIL 13.8kV 21kA 3 seconds 95kV BIL O O Cale earth switch 16kA 3 seconds Cale
High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv
High-Voltage Compact Switchgear AP1 DTC for 1 kv and kv Answers for energy. The AP1 DTC Complying with our Customers demands Experience you can rely on - at anytime, anywhere Decades of experience in high-voltage
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
Tape Wound, Split Core and Ebony Current Transformers
Tape Wound, Split Core and Ebony Current Transformers Table of contents Tape Wound Measuring and Protection Current Transformers 2 MR Series Measuring Range 3 PR Series Protection Range 4 Class PX Current
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
CEF 9 CEF-S 23 CEF-VT 27 CMF 31 WBP 39 WBT 47 BPS 61
FUSES Catalogue CEF 9 CEF-S 23 CEF-VT 27 CMF 31 WBP 39 WBT 47 BPS 61 INTRODUCTION The main function of current limiting fuses is to protect electrical apparatus, such as distribution transformers, motors
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
Auxiliary Relay. Type P8n, PQ8n, PN8n
Auxiliary Relay Type P8n, PQ8n, PN8n ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
SECTION 16461 DRY-TYPE TRANSFORMERS
SECTION 16461 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Furnishing and installation of and testing of cast resin dry type MV/LV distribution transformer in accordance with specifications and drawings. Any
Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.
Power Voltage Transformers for Air Insulated Substations THE PROVEN POWER. Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Power transformers. Special transformers Railway
Power transformers Special transformers Railway A leader in railway systems Our compact and low-weight transformers fully comply with the customer s specifications. The products are developed together
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application
Product overview brochure ABB Medium Voltage Products Our one-stop approach for every medium voltage application Overview ABB meets every need for reliable, safe and energy-efficient medium voltage switchgear,
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
PNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
Protection from Short-circuit
Protection from Short-circuit Back-up Fuse-Link with ÜLA (controlled power dissipation) Test device for tripping device Special version with threat High-voltage Fuse-Link for voltage transformers (HSW)
APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors
APPENDIX APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS RJ12 connectors Pin # 1 Signal Name Not Used 2 +TR Description + Data Line 3 +R Remote OFF Required or Remote OFF control 4 -TR 5 Not Used 6 RTN -
UFES Active protection for switchgear
Active protection for switchgear ABB AG Oberhausener Strasse 4047 Ratingen, Germany Phone: +49 0-0 Fax: +49 0-7 77 Note: We reserve the right to make technical changes or modify the contents of this document
Contact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.
METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component
NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
Using Current Transformers with the 78M661x
A Maxim Integrated Products Brand Using Current Transformers with the 78M661x APPLICATION NOTE AN_661x_021 April 2010 Introduction This application note describes using current transformers (CT) with the
Generators TEM. for small hydroelectric power stations. Electric Machines
Generators for small hydroelectric power stations TEM Electric Machines Advanced solutions for the cleanest energy Reputable manufacturer of generators for small hydroelectric power stations TED Electric
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Course No: E02-010 Credit: 2 PDH Boris Shvartsberg, Ph.D., P.E., P.M.P. Continuing Education
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
www.siemens.com/energy High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.
s www.siemens.com/energy High Voltage Circuit Breakers AP Type 7.5 kv to 800 kv Answers for energy. The AP High Voltage Circuit Breakers Available up to 800 kv Decades of our experience in high voltage
SINEAX U553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
Safety Relays ESM/ESM-F
Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
Current and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application