1 Transient Immunity Testing a handy guide
2 Think EMC test... Think The largest one-stop EMC test equipment supplier
3 Transient Immunity Testing a handy guide
4 4
5 The handy guide to transient tests Introduction As well as covering continuous radio frequency phenomena, EMC means ensuring product immunity from several sources of transient phenomena that are present in the electromagnetic environment. These phenomena can be natural, such as electrostatic discharge (ESD) and lightning surge, or man-made such as switching transients and fault surges. They involve short-duration (nanosecond or microsecond) events that have high enough amplitudes to disrupt the operation of electronic circuits and, in some cases, have enough energy to destroy or damage components. Except for ESD, the source of a transient is not normally near to the victim equipment, and its energy is almost entirely coupled into the circuits via cable connections. Therefore, immunity testing involves applying a repeatable pulse of a defined waveform and level into each relevant cable port, in a specified and reproducible manner. Apart from the rarely-used pulsed magnetic field and damped oscillatory wave tests of IEC and 10, there are no commercial tests which apply radiated transients. ESD is the special case which is the exception to this rule: it is applied from a simulator which attempts to mimic the real-world event, and includes both radiated and conducted components. Application of a series of transients is accompanied by monitoring the function of the EUT to determine whether it has been disrupted and, if so, whether the disruption is acceptable or not. This guide discusses the mechanisms involved in generating each type of transient, the standard tests that have been devised to deal with them, and some of the practical issues that arise in performing these tests. Some reference material on the standards is given at the end of the guide. 1
6 2
7 Electrostatic discharge The discharge event Charging mechanism All conductive objects have self-capacitance with respect to ground and mutual capacitance with respect to other bodies. This capacitance can maintain a DC charge with respect to ground, if the object is insulated from ground. Movement or separation of insulating surfaces causes charge transfer through the triboelectric mechanism, and this leaves a net deficit or surplus of free electrons on the conductive objects that are coupled to these surfaces. Alternatively, proximity to other electrostatically charged objects results in inductive charging. With perfectly insulating materials, this charge would remain on the object indefinitely, but in reality there is some surface and volume conductivity and the free electrons drift so that the charge differential is gradually neutralised. This occurs more rapidly with greater conductivity. Static dissipative materials and higher relative humidity are two ways to increase the conductivity. The charge Q is related to the voltage differential by the capacitance of the object: Q = C V For parallel plates, capacitance is determined by surface area A and separation distance d, as well as by the permittivity of the dielectric material within the separation gap: C = 0 r (A/d) 3 For irregular objects, the capacitance can be approximated by applying the above equation to elemental regions of the objects and summing the capacitance due to each element: C = i { 0 r (A i /d i )} where A i is the surface area of each element and d i is the distance between surfaces for each element. Human body capacitance depends on the size of the person and on their activity, i.e. whether they are sitting, standing or walking. In a moving person, all these factors come together to give a continuously varying voltage on that person. In the worst case highly insulating materials, low relative humidity and vigorous movement 3
8 the voltage may reach as high as 25kV. Charge potentials higher than this tend to be limited by corona effects. In more typical situations, voltages vary between 2-8kV. The effect on electronics When a charged object contacts another object at a different potential (this second object may be at ground potential but is not necessarily so), the charge is equalised between the two objects, and there is both a voltage v(t) and current i(t) transient as this occurs (Figure 1). The amplitude and waveform of the transient depends on the voltage difference and the total impedance in the equalisation current path. Figure 1 The typical personnel discharge scenario 4 Associated with the v(t) and i(t) are electric and magnetic field transients E(t) and H(t). All four of these aspects of the event will couple with electronic circuits that happen to be in the path of the current or near to the source of the field. This coupling creates induced transient voltages within the signal circuits themselves. Digital circuits in particular may respond to these induced pulses as if they were intentional signals, and their operation is consequently corrupted. 4
9 Design to avoid ESD problems includes: choose circuit configurations that are unresponsive to short transients lay out the PCB to minimise induced voltages at critical nodes prevent unavoidable discharge transients from coupling into circuits and cables design enclosures as far as possible to prevent discharges from occurring Secondary discharge A secondary discharge can occur within equipment if the discharge current through the product attempts to take a path which includes an air gap. The voltage across the gap increases until the gap breaks down, and this secondary breakdown can be more stressful for the circuits than the initial event, because it is closer to them and probably involves a lower path impedance. The breakdown occurs simultaneously with the applied primary discharge. Secondary discharge is best dealt with by ensuring that no sneak air gaps exist, or by making them large enough not to break down, or by bonding across them, and by avoiding sharp edges which encourage high field gradients. Figure 2 Mechanism of secondary discharge 5
10 The IEC standard test method and generator IEC and its EN equivalent is the principal basic standard for testing electrostatic discharge immunity. It applies a defined current waveform at a specified voltage level from a hand-held generator (Figure 3), which is essentially a capacitor supplied from a high voltage supply whose charge voltage is discharged via a series impedance through the point of contact to ground. Two methods are given: contact discharge and air discharge. Figure 3 The Schaffner NSG 435 ESD generator Contact discharge In the contact discharge method, the stress may be applied directly to the EUT or to a coupling plane adjacent to the EUT. Before each test pulse, the capacitor is charged to the desired level but its voltage is held off the generator's probe by a vacuum relay. The probe is applied to a suitably chosen point on the EUT or the coupling plane. The generator is then triggered, so that the relay contacts close and the capacitor voltage is applied through the probe to the EUT. This creates a pulse of current (with associated field and voltage transients) as the voltage discharges through the combined series impedance of the generator, the EUT and the ground plane. This action is repeated the desired number of times, at each location, with the appropriate polarities and levels. Air Discharge The same generator is used for the air discharge method, but with a rounded rather than a pointed probe tip. The capacitor is charged to the desired level as before, but the voltage is now continuously applied to the probe, which is held away from the EUT. For each test pulse, the tip is brought up to the chosen point on the EUT, smartly, until it touches. Just before this, the air gap between the tip and the EUT will break down and a discharge current will flow, 6
11 limited as before by the combined series impedance of the generator, the air gap, the EUT and the return path. Again, the action is repeated the desired number of times, at each location, with the appropriate polarities and levels. Figure 4 The ESD generator circuit and waveform Practical aspects of testing The test layout The recommended test layout is shown in Figure 5. The ESD pulse has a subnanosecond risetime and so radio frequency layout precautions are vital. The test must re-create the fast risetime found in reality, since this is an important parameter in deciding both the path the discharge takes through the EUT and the response of the EUT itself. The ground reference plane (GRP) is an integral part of the setup and the generator s return lead must be well bonded to it, since this connection forms part of the current return path. 7
12 Figure 5 ESD test layout 8
13 The indirect discharge part of the test uses two other planes, different from the GRP, known as the horizontal coupling plane (HCP) and the vertical coupling plane (VCP). Discharges to these planes simulate the stress caused by the radiated field from real-life discharges to nearby objects. Each coupling plane is connected to the GRP by a resistor lead, to ensure that any charge bleeds off within a few microseconds. The construction of these leads is critical: there should be a resistor close to each end, so that the length of lead between them is isolated from the connections and stray coupling to it is neutralised. Although power rating is unimportant, the resistors themselves should withstand a high pulse dv/dt without breaking down, for which carbon composition types are best suited. For the few tens of nanoseconds of the ESD event, the plane carries the full stress voltage, which is capacitively coupled to the EUT. Any stray capacitance from the plane to objects other than the EUT modifies the plane s voltage and current waveforms and hence the applied stress. Therefore, it is important to maintain at least 1m clear space around the EUT, which implies some separation of the tabletop setup from walls or other objects. Equally, the separation from the VCP to the EUT is specified as 10cm; even small variations in this distance can cause large changes in coupling to the EUT, so a convenient means of controlling it, such as plastic 10cm spacers on the surface of the plane, is helpful. Floating EUTs If the EUT has a ground connection, the charge that is applied by each test pulse will quickly dissipate, leaving the EUT ready for the next application. But this is not true for those EUTs which are isolated from ground such as handheld stand-alone devices, or safety Class II mains powered units. When a discharge is applied to these, charge moves from the 150pF capacitor of the discharge generator to the self-capacitance of the EUT, leaving it floating at some voltage above ground, the actual value depending on the ratio of capacitances (see Figure 6). This is fine on first application, but it means that the applied stress is progressively reduced on subsequent pulses of the same polarity and level, since the voltage difference between the generator and the EUT is diminishing. 9
14 Or, if the polarity is reversed, the EUT suffers a much greater applied stress than intended. Small EUTs may have only a few pf self-capacitance, meaning that they instantly reach nearly the full applied voltage, and subsequent pulses are worthless. Figure 6 Charging of ungrounded EUTs You should, therefore, bleed off the charge between each pulse application. Amendment 2 to the standard, recently published, achieves this by allowing a bleed resistor cable between the EUT and HCP during the test. As long as the resistors are mounted very near to the ends of the cable (within 2cm), the cable can remain in place during the test, since its presence probably won t affect the outcome although in cases of dispute, the cable should not be connected. As with the bleed resistors for the coupling planes, you should take some care to ensure that the resistors are capable of withstanding the full pulse voltage without breakdown. Alternatives to a permanently connected bleed cable are a bleed resistor brush, applied in between discharges for the same purpose the resistor must still be at the top end of the cable to ground, otherwise the discharge induced by the bleed could be worse than that applied by the ESD gun, leading to a failure of the wrong test; or the use of an air ioniser, to speed the natural discharge of the EUT. 10
15 Number, location and level of discharges The standard tells you to do 10 discharges in the most sensitive polarity at preselected points. Lower levels than the specification must also be satisfied so if for the typical compliance test you are doing 4kV contact and 8kV air, you must also do 2kV contact and both 2kV and 4kV air tests. The test stress is not necessarily linear, so that a product might fail at, say, 4kV and yet pass at 8kV, and this would be an overall failure. But the difficult question is, how do you preselect the appropriate points? Only points which are accessible during normal use are to be tested, but this is often not much of a limitation. Amendment 2 defines what is meant by accessible parts in more detail. Clause A.5 of the standard gives some guidance. Also, product standards such as EN may be more explicit than the basic standard. But the difficulty usually lies in establishing the most sensitive locations around the EUT. Exploratory testing using a high pulse repetition rate or higher level is sometimes helpful, if the EUT s immunity is only slightly greater than the specification, but this doesn t work if the design gives a good margin of immunity. It also exposes the EUT to greater stress than the compliance test calls for, which may not be acceptable in some cases. A prototype design may be weaker than the final product, and the weaknesses may be most marked at certain points, which are then prime candidates for the compliance test. But in the end, this question can only be resolved through the skill, experience and perseverance of the test engineer. Handling the ESD gun The stress applied to the EUT is not confined just to the voltage and current pulse appearing at the tip. There is a stray field around the front of the gun, and also around the ground return lead as it falls away from the gun. Both of these can couple to the EUT and modify the stress, so it is necessary to control them. You need to ensure that the ground lead does not drape over the EUT but is always held away from it; the standard advises that it is kept at least 20cm away from the EUT and any conductive parts other than its connection to the GRP. Equally, you should always hold the generator such that its probe is perpendicular to the EUT surface that is being tested, and not handle the generator near the probe. This will reduce the variability of coupling of the stray field around the front of the generator. 11
16 When the discharge is applied to the coupling planes, the gun should be held edge-on to the plane and opposite the centre of the EUT, for the HCP, or at the centre of one edge of the VCP. This is made explicit in Amendment 1: 1999 to the standard. As well as angle of incidence, for the air discharge test the speed of approach is important, since this affects the breakdown of the air gap. The standard says the discharge tip shall be approached as fast as possible (without causing mechanical damage) to touch the EUT. In the case of contact discharge, contact pressure is relevant; even a thin film of oxide can cause a high contact resistance, which can give dramatic variations in the applied waveform, so the tip must be pressed as hard as possible against the EUT surface. Figure 7 NSG Schaffner s 30kV ESD Gun for automotive and other stringent safety-critical testing 12
17 Electrical fast transient bursts Source and effect of transients When a circuit is switched off, the current flowing through the switch is interrupted instantaneously. Put another way, at the moment of switching there is an infinite di/dt. All circuits have some stray inductance associated with the wiring; some types of load, such as motors or solenoids, have considerably more inductance in the load itself. The voltage developed across an inductance L by a changing current i is V = -L di/dt If di/dt is infinite, then this implies an infinitely high voltage. Of course, this doesn t happen in practice since the rate of rise of voltage is limited by stray or intentional circuit capacitance. Even so, a high instantaneous voltage, added to the circuit operating voltage, does appear across the opening switch contacts. This causes the tiny but increasing air gap across the contacts to break down, and a current flows again, which collapses the voltage spike, so that the briefly formed arc extinguishes. But this re-interrupts the current, so another voltage spike appears, creating a further arc. This process repeats itself until the air gap is large enough to sustain the applied voltage without breakdown, at which point the circuit can be said to be properly switched off. The visible effect is a brief spark between the contacts, which actually consists of a whole series of microsparks, the so-called "showering arc", whose repetition rate and amplitude depend on the circuit and switch parameters. Figure 8 Transient burst generation 13
18 The i(t) and v(t) inherent in each spark event propagate along the circuit wiring. If this is a mains circuit, this burst of noise can appear at other points of connection to the mains distribution ring. Also since the pulses are very fast of the order of nanoseconds they couple effectively to other wiring in close proximity to the circuit wiring. Voltage peaks, typically of hundreds but occasionally thousands of volts, appear on any such coupled circuits. Burst characteristics The actual occurrence of these bursts, seen from the point of view of victim equipment which is unrelated to the source, is usually random although some automatic switching events can occur at regular intervals. Noise from brushed motors and arc welding, two special cases of the above mechanism, usually has a strong periodic content. The amplitude of the bursts decays with distance due to the lossy transmission-line characteristics of the wiring, and so it is usually only sources within a few metres of the victim that are significant. The burst waveforms are also random, although research has found that the repetition frequency tends to fall within the range 100kHz 1MHz, and the dv/dt of the rising edge is roughly proportional to the square root of the amplitude. Effect on electronics It is rare, though not impossible, for the transients to be coupled into a nearby victim by inductive coupling but, generally, they enter the product via the cable connections. On signal ports, the spikes are almost invariably in common mode, i.e. on all wires (or on the screen) at the same amplitude with respect to external earth. On the mains port, they may appear either in common mode or differentially between phases. Common mode coupling includes the protective earth wire. Poor filtering or inadequate screen termination on each interface then lets these transients pass into the electronic circuits where they appear as interfering signals at sensitive nodes. As with other types of transient, digital circuits tend to be more susceptible, since each short pulse can appear as a valid digital signal. Occurring in bursts, there is a higher probability that one or more pulses will coincide with a critical timing edge. However, analogue circuits can also be affected, typically by saturation of sensitive amplifiers. Pulse counting circuits are also susceptible if the burst masquerades as a real input. 14
19 Good design practice takes two forms: the internal circuit design is bandwidth limited wherever possible, and the PCB layout prevents large interference voltages from appearing within the circuit; all interfaces must be filtered or screened to a structural low impedance earth so that common mode pulses are prevented from entering the circuit. The IEC standard test method and generator IEC and its EN equivalent is the principal basic standard for testing fast transient immunity. It applies a specified burst waveform via a defined coupling network to the mains connection and via a defined clamp device to any signal connection. Only conducted coupling is used; there is no specification for radiated transient immunity. Choice of ports for the application of the burst depends on the instructions in the product standard being used, but it is generally applied to AC and DC power ports and to signal and control ports that may be connected to cables longer than 3m. Figure 9 Test setup for mains port 15
20 Figure 10 Test setup for signal ports The power port CDN is essentially an inductor in series with the lines to isolate the burst application from the supply input, in combination with a capacitor feeding the burst voltage onto the chosen line(s). All lines may have the burst applied, including the protective earth, which must, therefore, also include a decoupling inductor. The capacitive clamp is a pair of metal plates, connected together and hinged down one edge so that they can sandwich the cable under test between them. It is expected that the cable under test will be insulated and, therefore, there is no direct connection, only a capacitive one if the cable insulation is weak or nonexistent this should be anticipated and some extra insulation provided. Because of the length of the clamp, the capacitive coupling is distributed, which improves repeatability for the higher frequency components of the transients. The clamp must also be located a defined distance above the ground plane, and the burst voltage is applied with respect to this ground plane. 16
21 Figure 11 The Schaffner CDN An example of a coupling clamp Waveforms The burst waveform definitions are shown in Figure 12. To standardise the test, the waveshape, number of pulses, their frequency and the burst length and repetition frequency are all specified. It should be understood that these specifications are explicitly not representative of real life which, as mentioned earlier, sees pulse repetition rates in the hundreds of khz. Instead, they represent the lowest common denominator of what is achievable and repeatable in test generators. It is possible to program most generators for other values and this may be helpful when you are testing your products for their immunity to real (variable) bursts. The source impedance of the generator is required to be 50Ω and the waveform is calibrated into a 50Ω load and, in the future, according to a new amendment, also into 1000Ω. The load impedance presented by the EUT is unknown and may be anything from a near short circuit, for a screened cable port on an EUT that is well earthed, to a near open circuit for an unscreened port with a series common-mode choke at the interface. Therefore, the actual voltage that appears between the EUT port and the ground plane is similarly unpredictable. The aim of the new amendment is that the waveform of the burst pulse should not change between different generators and different EUTs. 17
22 Figure 12 The burst specification 18
23 Practical aspects of testing The transient burst voltage is applied to the power port(s) of the EUT via a coupling/decoupling network (CDN), and to other ports via a capacitive coupling clamp. The voltage is referenced to the ground plane connection point on the test generator. The basic standard is not entirely clear about how the burst should be applied through the CDN (Figure 13). The standard shows it being applied separately to live, neutral and earth lines, but some product standards which call up this test have referred to it as common mode, that is on all three lines simultaneously. Schaffner generators such as the NSG 3025 allow you to select any mode of coupling. The result of the test could well be different depending on which type of coupling you choose. Figure 13 Coupling the burst through the CDN In practice, the choice is a matter of interpretation and either interpretation could be justified. If you are using the test to check the real-life immunity of your product, it would be best to apply all different modes of coupling, but if you need to stick closely to the letter of a product standard, a restricted interpretation may be reasonable. The question does not arise with the capacitive clamp, which inherently applies the burst in common mode. 19
24 The test layout This is a high frequency test the spectrum of the burst extends to hundreds of MHz and a ground reference plane (GRP) is essential. Trying to do a development test without a ground plane will lead to unrepeatability and lack of correlation to the compliance test. Stray impedances are controlled by the following restrictions: The EUT should be 10cm above the GRP (80cm for table-top equipment); The GRP should extend at least 10cm beyond the EUT on all sides; The EUT and the capacitive coupling clamp should be at least 0.5m from all other conducting structures, including the test generator and the walls of the room; The length of the cable between the coupling device (clamp or CDN) and the EUT must be 1m or less, with any excess in the mains cable coiled (not bundled) in a 0.4m diameter loop it is best to use a standard 1m test cable for all EUTs, regardless of what they are supplied with; The test generator must be bonded to the GRP with a lowinductance connection, such as a short bracket or braid. Any inductance at this point will lift the generator output waveform off the GRP and introduce ringing on the signal that appears at the EUT. This also applies to the earth plate of the capacitive clamp, which terminates the high voltage coax cable that comes from the generator. This lead must be connected to the end of the clamp nearest the EUT although clamps are provided with connectors at either end, you have no choice as to which to use in the actual setup. The test layout needs some thought to achieve all these requirements together. Any deviation will affect the stray inductance or capacitance in the coupling path, which in turn will cause variations in the applied stress. But, for instance, it can be difficult to ensure a distance of less than 1m for the signal cable between the coupling clamp which must be mounted on the GRP, and a tabletop EUT which must be 80cm above it, if the cable port is on the top of a tall EUT. Such difficulties require a departure from the letter of the standard which must be carefully assessed and recorded. 20
25 Burst application The basic standard specifies that the bursts should be applied for at least one minute in each polarity. Some product standards modify this, for instance to two minutes. The main concern is that bursts should be applied for long enough that any coincidence with sensitive states of the EUT has been explored. The product standards also define to what ports the test must be applied. A common qualification is that ports which are connected to cables that are limited to less than 3m in length, are excluded from the test. There is nothing magic about the 3m figure, but the intention is to acknowledge that short cables are unlikely to couple significant amounts of burst interference in real life. Nevertheless, this puts some responsibility on the manufacturer to decide which ports can sensibly be included in this restriction. Annex A of IEC gives some information in this respect. Figure 14 NSG Burst Generator For on-site use, a handy test generator with autonomous functions is required. And for laboratory use, the generator needs to offer extended functionality for product investigation and automated operation for certification work. The NSG 3025 satisfies all these requirements from one compact unit. 21
26 Surge The causes and effects of surges High energy transients appearing at the ports of electronic equipment are generally a result either of nearby lightning strikes, or are due to major power system disturbances such as fault clearance or capacitor bank switching. Lightning can produce surges with energies of several joules by the following mechanisms (Figure 15): direct strike to primary or secondary circuits: the latter can be expected to destroy protective devices and connected equipment; the former will pass through the service transformers either by capacitive or transformer coupling indirect cloud-to-ground or cloud-to-cloud strikes create fields which induce voltages in all conductors ground current flow I G from nearby cloud-to-ground discharges couples into the grounding network via common impedance paths, and causes substantial potential differences between different ground points primary surge arrestor operation or flashover in the internal building wiring causes voltage transients Lightning protection of buildings and their installations is covered by various standards, including IEC :1993, IEC :1995 and BS 6651:1992. These standards define hierarchical protection zones within installations, but they admit some level of surges even in the deepest zone, so there is still a need to ensure that individual products can show a degree of immunity from lightning-induced surges. 22
27 Figure 15 Surge generation Fault clearance upstream in the mains supply distribution network produces transients with energy proportional to 0.5 L I 2 trapped in the power system inductance. The energy will depend on the let-through current of the clearance device (fuse or circuit breaker) which can be hundreds of amps in residential or commercial circuits, and higher for some industrial supplies. Power factor correction capacitor switching operations generate damped oscillations at very low frequency (typically khz) lasting for several hundred microseconds. Effect on equipment Surges impinging on electronic equipment may cause hardware damage and complete failure, or in lesser cases, operational upset. Figure 13 gives an indication of the relationship between surge parameters and these effects. Below some level dependent on equipment design, no effect is observed. Above this level, a surge may cause the operation of the equipment to change state, without any long-term effect on the circuit components. But at a higher level, there may be enough energy to cause breakdown in critical components. The maximum voltage that is likely to occur is limited by flashover considerations, for instance in a typical domestic mains supply no more than about 6kV can be withstood by the wiring components. The designer has to know what surge voltage can be sustained by the product's interfaces without protection, and what voltage is expected in the protection zone in which the product will be used, in order to decide whether any of these interfaces need additional protection. 23
28 Typically, protection involves adding parallel surge suppression devices such as clamping diodes, varistors or spark gaps. The purpose of these devices is to break down in a controlled manner at a voltage lower than can be sustained by the circuit, and dissipate the surge energy within themselves. They must therefore, be sized to withstand the maximum surge energy to be expected in a particular application. The rate-of-change of applied voltage and current also has a bearing on both the susceptibility of a particular interface to upset and on the ability of protection devices to cope with the surge. Figure 16 Relationships between surge parameters and equipment effects flashover/energy boundary Transient amplitude volts or amps tens hundreds thousands DAMAGE UPSET dv/dt (di/dt) boundary NO EFFECT approximate boundary of real-world events microseconds milliseconds seconds Duration 24
29 Standard test waveforms IEC defines the 1.2/50µs V 8/20µs I combination wave. It also refers to the CCITT (ITU K.17) 10/700µs wave to be applied to telecom ports. IEC defines the waveform for the ring wave. Combination wave The surge generator called up in the test to IEC has a combination of current and voltage waveforms specified, since protective devices in the EUT (or if they are absent, flashover or component breakdown) will inherently switch from high to low impedance as they operate. Thus part of the surge will be delivered into a high impedance and part into a low impedance. The values of the generator s circuit elements are defined so that the generator delivers a 1.2/50µs voltage surge across a high-resistance load (more than 100Ω) and an 8/20µs current surge into a short circuit (Figure 18). These waveforms must be maintained with a coupling/decoupling network in place, but are not specified with the EUT itself connected, and for coupling devices for signal lines this requirement is waived. Since the surge waveform is specified as both a voltage and current, it has to be calibrated into both an open circuit and a short circuit. Figure 17 The Schaffner Best Compact Test System for Burst, ESD, Surge and Transient benchtop compliance testing 25
30 Figure 18 The combination surge waveform Ring wave Measurements have shown that most surge voltages in indoor supply systems have oscillatory waveforms. Even if it is unidirectional to start with, an incoming surge excites the natural resonances of the system. The frequency of oscillation can vary between khz and can have different amplitudes and waveforms at various places in the system. IEC defines a "ring wave" with the characteristics shown in Figure 19. It is said to be representative of a wide range of electromagnetic environments of residential and industrial installations. Despite this, it has not found favour with product committees who are responsible for choosing basic standard tests and, as a result, it is not widely applied in product testing. Generator output Minimum repetition Application impedance Z period 12Ω 10s EUT supply ports connected to major feeders; application between communication ports on cabinets interconnected with 10m long screened data comms cables 30Ω 6s EUT supply ports connected to outlets 200Ω 1s I/O ports, unless the test involves protection devices or filters, in which case 12Ω or 30Ω is applicable 26
31 Figure 19 The ring wave Telecom waveforms For ports connected to telecommunications lines, a further 10/700µs surge is required. The voltage waveform is specified in the same way as for the combination wave above, with a front time of 10µs ±30% and a time to half value of 700µs ±20%. No current waveform is shown, instead the component values of the waveform generator are provided. The generator has an output resistance of 25Ω which may be provided either internally or by external coupling resistors (see top diagram of Figure 21). Practical aspects of surge application Because of the lower frequency spectrum content of the surge waveforms, surge testing is more tolerant of layout variations, and the standards are fairly relaxed in this respect. The cable between the EUT and the coupling/decoupling network should be 2m or less in length (1m for the ring wave). For the combination wave and telecom wave there are no other explicit restrictions on the layout. The ring wave test is best carried out over a ground plane, but even this can be waived for table-top equipment if the earthing connections are well controlled. 27
32 Safety However, you should remember that the surge has a high energy content. The peak voltage that can be applied is 4kV, and the peak current is 2kA. This means that some protective safety measures are at the least advisable and in some cases, essential. If there is any likelihood that the surge voltage could appear on external conductive parts, for instance because the integrity of the earth connection is not assured or because, as in the test on screened line interfaces, you are applying the surge directly to the enclosure then personnel must be kept away from the EUT during the test. In any case, the EUT should be disconnected from other equipment where possible and the whole setup should be well insulated to prevent flashover. Also, high resistances in the path of the surge current will be subject to high dissipation and could overheat with a consequent fire risk. The same applies to surge suppressors within the EUT, which despite the mandatory one-minute cooling-off period may fail catastrophically. Make sure all appropriate connections are tight and capable of taking the expected current, and keep a fire extinguisher handy. Coupling For coupling to the mains supply of the combination wave, the generator is connected directly via a 18µF capacitor across each phase, but through a 10 ohm resistor and 9µF capacitor for phase-to-earth application (Figure 16). This means that the highest energy available from the generator s effective source impedance of 2 ohms is actually only applied between phases. The signal line coupling networks include a 40 ohm series resistor, which reduces the energy in the applied surge substantially. Coupling to signal lines (Figure 21) has to be invasive; no clamp-type devices are available for this test. It is permissible to use gas discharge tube coupling for signal lines to maintain bandwidth. A separate method is used for shielded lines, in which the surge is effectively applied longitudinally along the shield, by coupling it directly to the EUT at one end of a non-inductively bundled 20m length of cable, with the further end grounded. 28
33 Figure 20 Surge coupling to supply lines Figure 21 Surge coupling to signal lines 29
34 Procedure The test procedure requires the following steps, bearing in mind that an agreed test plan may modify them: Apply at least five positive and five negative surges at each coupling point, but preferably a sufficient number of pulses to find all critical points of the duty cycle of the equipment Wait for at least a minute between applying each surge, to allow time for any protection devices to recover Apply the surges line to line (three combinations for 3-phase delta, six for 3-phase star, one for single phase) and line to earth (two combinations for single phase, three for 3-phase delta, four for 3-phase star) Synchronise the surges to the zero crossings and the positive and negative peaks of the mains supply (four phase values) Increase the test voltage in steps up to the specified maximum level, so that all lower test levels are satisfied the step size being generally interpreted as a level at a time, rather than a fixed voltage step such as 500V Figure 22 Surge application period between surge pulses determined by EUT protection capability surge voltage increased in level steps to maximum For AC lines, synchronise surges to peaks (both polarities)......and zero crossings A worst case interpretation of the requirements on a three-phase star supply being tested up to level 4 would imply that a single complete test would take nearly 27 hours, not allowing for setup and test sequencing time. 30
35 The rationale for all lower levels must be satisfied is that the behaviour of many types of surge suppression is likely to vary between low and high values of surge voltage. A suppressor that would break down and limit the applied voltage when faced with a high level, may not do so at lower voltages, or may at least behave differently. The worst case could well be at just below the breakdown voltage of an installed suppression device. Equally, the EUT response can change either because of circuit operation or because of suppressor behaviour when the surge occurs at varying times during the mains cycle. For example, an unfiltered circuit that looks for zero crossings will have an undesired response when a negative-going surge occurs at the positive peak of the cycle. Unless you are very confident of your EUT s performance in these various conditions, pre-compliance testing over as wide a range of variables as possible is advisable. Figure 23 The Schaffner System A complete conducted immunity test system System 2050 is a highly versatile, modular, multi-role EMC test facility adaptable to meet a wide variety of test specifications. System 2050 offers a complete set of plug-in networks for full compliance testing to basic, generic and product standards, for single-phase and three-phase power lines as well as data and telecom lines. As needs grow and change, System 2050 can be extended accordingly, thereby protecting investment. FCC pt 68 upgrade A single plug-in unit generates all five surge pulses required by FCC pt 68. For more detailed product characterization, settings can be modified via the front panel keypad and display or via WIN 2050 software. 31
36 Reference Material - Generic & Product Standard Requirements Standard Scope DOW* ESD EFT Surges EN : 1992 Residential, commercial & light industrial generic N/A 8kV air discharge, to IEC 801-2: kV AC power, 0.5kV DC power, signal and control > 3m to IEC 801-4: 1988 Not required (informative annex only) EN : st July kV contact, 8kV air to EN kV AC power, 0.5kV DC power > 10m, signal and functional earth > 3m to EN kV L-L, 2kV L-E on AC power input; 0.5kV L-L & LE DC power > 10m, to EN EN : 1995 Industrial generic N/A 4kV contact, 8kV air to EN kV AC & DC power and PMC, 1kV other signal >3m to EN Not required (informative annex only) EN : st April kV contact, 8kV air to IEC kV AC & DC power, 1kV signal and functional earth >3m to IEC kV L-L, 2kV L-E on AC power; 0.5kV L-L & L-E DC power > 10m; 1kV L-E signal > 30m, to IEC EN : 1997 Household appliances etc. 1st Jan kV contact, 8kV air to EN kV AC power, 0.5kV DC power, signal and control > 3m to EN kV L-L, 2kV L-E on AC mains, to EN EN 55020: A12: 1999 Broadcast receivers etc. 1st Aug kV contact, 8kV air to EN kV AC power to EN Not required EN 55024: 1998 Information technology equipment 1st July kV contact, 8kV air to IEC kV AC power, 0.5kV DC power, signal and telecom > 3m to IEC kV L-L, 2kV L-E on AC mains, 0.5kV L-E on DC power with outdoor cables, to IEC ; 1.5kV 10/700µs on signal/telecom ports with outdoor cables, to ITU-T K recs. EN : 1995 Fire, intruder and social alarm systems 1st Jan kV contact, 8kV air to IEC 801-2:1991 2kV AC mains supply, 1kV other supply/signal lines to IEC kV L-L, 2kV L-E on AC mains supply; 1kV L-E other supply/ signal lines, to IEC EN 61326: 1997 Measurement, control and lab equipment, min. requirements 1st July kV contact, 4kV air to IEC kV AC & DC power, 0.5kV I/O signal/control >3m to IEC kV power L-L, 1kV power & long distance I/O signal/control L-E to IEC EN 61547: 1995 General lighting equipment 1st July kV contact, 8kV air to IEC kV AC power, 0.5kV DC power, signal and control > 3m to IEC kV L-L, 1kV L-E on AC power, to IEC EN : 1997 Telecom network equipment, immunity only Telecom centres 30th Sept kV contact, 4kV air to EN kV AC power, 0.5kV DC power, outdoor signal and indoor signal > 3m to EN kV L-L, 1kV L-E on AC power; 0.5kV L-E indoor signal > 10m, to EN ; 1kV 10/700µs on outdoor signal lines, to EN Not telecom centres 6kV contact, 8kV air to EN kV AC power and DC power > 3m, 0.5kV outdoor signal and indoor signal > 3m to EN kV L-L, 2kV L-E on AC power; 0.5kV L-E indoor signal > 10m, to EN ; 1kV 10/700µs on outdoor signal lines, to EN * DOW = date of withdrawal (or, "date of cessation of presumption of conformity") of the superseded standard L-L = line to line; L-E = line to earth; PMC = process, measurement and control ports Always check the appropriate standard for detailed applicability 32
37 Equations Except for ESD, these equations for the waveshape of the quoted transient waveforms are derived from IEEE C62.41:1991. ESD current waveform (4kV indicated voltage, t in ns) Surge voltage 1.2/50µs waveform (t in µs) EFT 5/50ns waveform (t in ns) 0.5µs/100kHz ring waveform (t in µs, = 2π 10 5 rad/s) Surge and transient energy The energy content of transients and surges is not simple to define. Not all the actual energy stored in the test generator is dissipated in the load. That proportion which is, depends on the ratio of the load and generator impedances. In general, a load such as a surge suppressor will be non-linear and will also have a time or frequency dependence. The "energy measure" of a given waveform can be described by which gives the energy that would be delivered by that voltage waveform into a 1Ω resistor, whether or not the generator is capable of this (i.e., assuming zero output impedance). These figures are shown in the right-hand graph of Figure
38 Alternatively, the actual energy delivered by the generator into a defined resistive load can be calculated. For the ESD and EFT waveforms, these can be the calibration loads of 2Ω and 50Ω respectively. For the surge and ring waves, a load which matches the output impedance can be chosen, and the voltage or current waveform is delivered into this resistance with half the open circuit (or short circuit, for current) amplitude although this simplifying assumption does not occur in practice as the current and voltage waveforms vary depending on the load impedance. In these cases, the energy in Joules (watt seconds) is shown in the left-hand graph of Figure 24 and is given by where V(t) and I(t) are the open circuit voltage and short circuit current waveforms, respectively. These graphs are for comparative purposes only the real energy delivered to a particular EUT can only be calculated if the load impedance and characteristics, and the actual waveshape applied to this load, are known accurately. The symbols on the graphs represent test levels 1 to 4 as defined in each standard. Figure 24 Transient energy content energy W 0.01 Joules Surge - 1.2/50us V, 2 ohm Surge - 1.2/50us V, 12 ohm Surge - 1.2/50us V, 42 ohm Surge - 8/20us I,2 ohm Ring - 12 ohm Ring - 30 ohm Ring ohm EFT - single pulse EFT - 1 sec ofbursts* ESD into 2 ohm * level 4 reduced due to halved repetition rate 100 energy measure S V 2 s Surge Ring EFT single pulse EFT 1 sec ofbursts* * level 4 reduced due to halved repetition rate peak open circuit voltage kv peak open circuit voltage (indicated voltage, ESD) kv 34
39 References IEC Ed. 1 + A1 + A2: Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 2: Electrostatic discharge immunity test. Basic EMC Publication IEC Ed. 1.0: Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 4: Electrical fast transient/burst immunity test. Basic EMC Publication IEC Ed. 1.0: Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 5: Surge immunity test IEC Ed. 1.0: Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 12: Oscillatory waves immunity test. Basic EMC Publication IEEE C : IEEE Recommended Practice on Surge Voltages in Low- Voltage AC Power Circuits ITU-T Recommendation K.17 (1993): Tests on Power-Fed Repeaters using Solid-State Devices in order to check the Arrangements for Protection from External Interference 35
40 36
41 Index Section headings Page Number Introduction 1 Electrostatic discharge 3 The discharge event 3 The IEC standard test method and generator 6 Practical aspects of testing 7 Electrical fast transient bursts 13 Source and effect of transients 13 The IEC standard test method and generator 15 Practical aspects of testing 19 Surge 22 The causes and effects of surges 22 Standard test waveforms 25 Practical aspects of surge application 27 Reference material 32 Generic and product standard requirements 32 Equations 33 Surge and transient energy 33 References 35 Index 37 37
42 Index Figures & Tables Page Number Figure 1 The typical personnel discharge scenario 4 Figure 2 Mechanism of secondary discharge 5 Figure 3 The Schaffner NSG 435 ESD generator 6 Figure 4 The ESD generator circuit and waveform 7 Figure 5 ESD test layout 8 Figure 6 Charging of ungrounded EUTs 10 Figure 7 The Schaffner NSG kV ESD Gun 12 Figure 8 Transient burst generation 13 Figure 9 Test setup for mains port 15 Figure 10 Test setup for signal ports 16 Figure 11 The Schaffner CDN 8014 Coupling Clamp 17 Figure 12 The burst specification 18 Figure 13 Coupling the burst through the CDN 19 Figure 14 The Schaffner NSG 3025 Burst Generator 21 Figure 15 Surge generation 23 Figure 16 Relationships between surge parameters and equipment effects 24 Figure 17 The Schaffner BEST Compact Test System 25 Figure 18 The combination surge waveform 26 Figure 19 The ring wave 27 Figure 20 Surge coupling to supply lines 29 Figure 21 Surge coupling to signal lines 29 Figure 22 Surge application 30 Figure 23 The Schaffner System 2050 Immunity Test System 31 Figure 24 Transient energy content 34 38
43 2002 Schaffner EMC Systems. Specifications subject to change without notice. This brochure is only intended as a guide. For full technical specifications and up to date information, please visit our website at; All trademarks recognised. Schaffner group manufacturing companies are ISO-registered. Their products are designed and manufactured under the strict quality requirements of the ISO 9000 standard. This document has been carefully checked. However, Schaffner does not assume any liability for errors or inaccuracies. HEADQUARTERS Schaffner EMV AG CH-4542 Luterbach Switzerland Tel: [+41] Fax: [+41] [email protected] China: France: Germany: Italy: Japan: Singapore: Switzerland: UK: USA: A
AN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x
TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x On January 1, 1996, exports into Europe began facing some tough transient immunity standards. The International Electrotechnical Commission (IEC), a worldwide
Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W
14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02
TEST REPORT EN 55014-2 (1997) +A1 (2001)
Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....
UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS
Page 1 UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS By Henry Ott Consultants Livingston, NJ 07039 (973) 992-1793 www.hottconsultants.com [email protected] Page 2 THE BASIC
Telecommunication Line Protectors
TN CR 0025 Telecommunication Line s 1.1 The nature of telecom surges The telecom services considered in this report are transported on twisted pair. Each service has two wires, or lines, sometimes called
White Paper: Electrical Ground Rules
Acromag, Incorporated 30765 S Wixom Rd, Wixom, MI 48393 USA Tel: 248-295-0880 Fax: 248-624-9234 www.acromag.com White Paper: Electrical Ground Rules Best Practices for Grounding Your Electrical Equipment
Design Guide for the Control of ESD in the esata Interface
Design Guide for the Control of ESD in the esata Interface Pat Young Principal Engineer Silicon Image, Steelvine Storage Products Scope This document is an informative design guideline only. It is intended
Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content
Charged cable event David Pommerenke, [email protected], 916 785 4550 Last update: Feb.23, 2001 Content Goal Energy sources, which may lead to CDE. Complexity of the different discharge modes. Possible
EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.
EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory
Current Probes, More Useful Than You Think
Current Probes, More Useful Than You Think Training and design help in most areas of Electrical Engineering Copyright 1998 Institute of Electrical and Electronics Engineers. Reprinted from the IEEE 1998
AN3353 Application note
Application note IEC 61000-4-2 standard testing Introduction This Application note is addressed to technical engineers and designers to explain how STMicroelectronics protection devices are tested according
Line Reactors and AC Drives
Line Reactors and AC Drives Rockwell Automation Mequon Wisconsin Quite often, line and load reactors are installed on AC drives without a solid understanding of why or what the positive and negative consequences
Technical Article MS-2443
. MS-2443 Safeguard Your RS-485 Communication Networks from Harmful EMC Events by James Scanlon, Senior Evaluation Engineer, Analog Devices, Inc., and Koenraad Rutgers, Senior Field Applications Engineer,
RC NETWORKS SALES GUIDE
SALES GUIDE INTRODUCTION TO Recent developments in electronic equipment have shown the following trends: Increasing demands for numerical control machines, robotics and technically advanced appliances
LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO
LED PORTFOLIO LUXEON LEDs Circuit Design and Layout Practices to Minimize Electrical Stress Introduction LED circuits operating in the real world can be subjected to various abnormal electrical overstress
Some considerations for ESD testing
Some considerations for ESD testing Tim Williams Elmac Services Introduction: Why We Do It A very good test of the general robustness of a digital product is that of electrostatic discharge immunity (ESD),
Cable Discharge Event
Cable Discharge Event 1.0 Introduction The widespread use of electronic equipment in various environments exposes semiconductor devices to potentially destructive Electro Static Discharge (ESD). Semiconductor
Current Probes. User Manual
Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall
Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise
TDK EMC Technology Product Section Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise TDK Shonai Corporation Satoru Saito Reduce Emission Noise from Cables Even if an electronic
Digital Energy ITI. Instrument Transformer Basic Technical Information and Application
g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER
Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power
App Notes ~ Outdoor Power System Design and Cost Considerations 1 Authors Peter Nystrom President TSi Power Corp. Coordination of Telecommunications Surge Protective Devices in Countries with Unstable
Grounding Demystified
Grounding Demystified 3-1 Importance Of Grounding Techniques 45 40 35 30 25 20 15 10 5 0 Grounding 42% Case 22% Cable 18% Percent Used Filter 12% PCB 6% Grounding 42% Case Shield 22% Cable Shielding 18%
Power surges can also be generated by equipment in your facility such as:
Power Quality Surge Suppressors What is Surge Protection A surge suppressor can be the first and best defense against the instant or gradual destruction of electrical equipment. Compared to the replacement
Experiment 8: Undriven & Driven RLC Circuits
Experiment 8: Undriven & Driven RLC Circuits Answer these questions on a separate sheet of paper and turn them in before the lab 1. RLC Circuits Consider the circuit at left, consisting of an AC function
A Practical Guide to Dielectric Testing
Chroma Systems Solutions, Inc. A Practical Guide to Dielectric Testing 19032 Series Electrical Safety Analyzer & 19050 Series Hipot Tester AC/DC/IR/SCAN Keywords: Dielectric tests, insulation resistance
Application Note, Rev.1.0, September 2008 TLE8366. Application Information. Automotive Power
Application Note, Rev.1.0, September 2008 TLE8366 Automotive Power Table of Contents 1 Abstract...3 2 Introduction...3 3 Dimensioning the Output and Input Filter...4 3.1 Theory...4 3.2 Output Filter Capacitor(s)
Output Ripple and Noise Measurement Methods for Ericsson Power Modules
Output Ripple and Noise Measurement Methods for Ericsson Power Modules Design Note 022 Ericsson Power Modules Ripple and Noise Abstract There is no industry-wide standard for measuring output ripple and
Power Supplies. 1.0 Power Supply Basics. www.learnabout-electronics.org. Module
Module 1 www.learnabout-electronics.org Power Supplies 1.0 Power Supply Basics What you ll learn in Module 1 Section 1.0 Power Supply Basics. Basic functions of a power supply. Safety aspects of working
IEC 1000-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays
IEC 00-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays Application Note July 1999 AN9612.2 Author: Wayne Austin The SP720, SP721, SP723, and SP724 are protection
Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies
Soonwook Hong, Ph. D. Michael Zuercher Martinson Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies 1. Introduction PV inverters use semiconductor devices to transform the
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on
Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter
Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Model: Solid State Energy Meter Prepared for: Analog Devices, Inc. 804 Woburn Street Wilmington, MA 01887 Date of
Critical thin-film processes such as deposition and etching take place in a vacuum
WHITEPAPER INTRODUCING POWER SUPPLIES AND PLASMA Critical thin-film processes such as deposition and etching take place in a vacuum SYSTEMS chamber in the presence of a plasma. A plasma is an electrically
EMC Standards: Standards of good EMC engineering
Electromagnetic Compatibility (EMC) IEEE Definition Origin, control, and measurement of electromagnetic effects on electronic and biologic systems. IEEE EMC Society Areas of Interest EMC Standards: Standards
CAN bus ESD protection diode
Rev. 04 15 February 2008 Product data sheet 1. Product profile 1.1 General description in a small SOT23 (TO-236AB) Surface-Mounted Device (SMD) plastic package designed to protect two automotive Controller
ECEN 1400, Introduction to Analog and Digital Electronics
ECEN 1400, Introduction to Analog and Digital Electronics Lab 4: Power supply 1 INTRODUCTION This lab will span two lab periods. In this lab, you will create the power supply that transforms the AC wall
Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions
PreCompliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions D. Schneider 1*, S. Tenbohlen 1, W. Köhler 1 1 Institute of Power Transmission and
Electromagnetic Compatibility Considerations for Switching Power Supplies
Electromagnetic Compatibility Considerations Characterization of the EMI problem requires understanding the interference source Switching power supplies generate Electromagnetic Interference (EMI) by virtue
Lightning current simulation in the laboratory - parameters, procedures and test equipment -
Lightning current simulation in the laboratory - parameters, procedures and test equipment - Dipl.-Ing. J. Schönau, Dr.-Ing. M. Naß, CE-LAB GmbH Prof. Dr.-Ing. F. Berger, Ilmenau University of Technology
PESDxU1UT series. 1. Product profile. Ultra low capacitance ESD protection diode in SOT23 package. 1.1 General description. 1.
Rev. 02 20 August 2009 Product data sheet 1. Product profile 1.1 General description Ultra low capacitance ElectroStatic Discharge (ESD) protection diode in a SOT23 (TO-236AB) small SMD plastic package
How to design SMPS to Pass Common Mode Lightning Surge Test
Application Note, V1.0, September 2006 How to design SMPS to Pass Common Mode Lightning Surge Test Power Management & Supply N e v e r s t o p t h i n k i n g. Edition 2006-09-06 Published by Infineon
Inrush Current. Although the concepts stated are universal, this application note was written specifically for Interpoint products.
INTERPOINT Although the concepts stated are universal, this application note was written specifically for Interpoint products. In today s applications, high surge currents coming from the dc bus are a
Module 11: Conducted Emissions
Module 11: Conducted Emissions 11.1 Overview The term conducted emissions refers to the mechanism that enables electromagnetic energy to be created in an electronic device and coupled to its AC power cord.
EMI and t Layout Fundamentals for Switched-Mode Circuits
v sg (t) (t) DT s V pp = n - 1 2 V pp V g n V T s t EE core insulation primary return secondary return Supplementary notes on EMI and t Layout Fundamentals for Switched-Mode Circuits secondary primary
AN-6 COMMON MISTAKES IN LIGHTNING PROTECTION OF PHONE LINE INTERFACE CIRCUITS
AN-6 COMMON MISTAKES IN LIGHTNING PROTECTION OF PHONE LINE INTERFACE CIRCUITS By Joe Randolph Introduction Lightning protection of phone line interface circuits is a complicated topic. The specific protection
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 46 2007. Test Method for AC to DC Power Supplies
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 46 2007 Test Method for AC to DC Power Supplies NOTICE The Society of Cable Telecommunications Engineers (SCTE)
POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS
A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS By: Robert G. Ellis, P. Eng., Rockwell Automation Medium Voltage Business CONTENTS INTRODUCTION...
Test Report #: 1981-3 Date: April 8, 2005
Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model
METHODS FOR THE CALIBRATION OF ELECTROSTATIC MEASURING INSTRUMENTS
METHODS FOR THE CALIBRATION OF ELECTROSTATIC MEASURING INSTRUMENTS Contents Foreword --------------------------------------------------------------------------------------------------------------------
ε: Voltage output of Signal Generator (also called the Source voltage or Applied
Experiment #10: LR & RC Circuits Frequency Response EQUIPMENT NEEDED Science Workshop Interface Power Amplifier (2) Voltage Sensor graph paper (optional) (3) Patch Cords Decade resistor, capacitor, and
Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820
Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)
DIRECT CURRENT GENERATORS
DIRECT CURRENT GENERATORS Revision 12:50 14 Nov 05 INTRODUCTION A generator is a machine that converts mechanical energy into electrical energy by using the principle of magnetic induction. This principle
= V peak 2 = 0.707V peak
BASIC ELECTRONICS - RECTIFICATION AND FILTERING PURPOSE Suppose that you wanted to build a simple DC electronic power supply, which operated off of an AC input (e.g., something you might plug into a standard
AND8229/D. An Introduction to Transient Voltage Suppression Devices APPLICATION NOTE
An Introduction to Transient Voltage Suppression Devices Prepared by: Jim Lepkowski ON Semiconductor APPLICATION NOTE INTRODUCTION Transient Voltage Suppression (TVS) protection devices such as shielded
Application Note AN:005. FPA Printed Circuit Board Layout Guidelines. Introduction Contents. The Importance of Board Layout
FPA Printed Circuit Board Layout Guidelines By Paul Yeaman Principal Product Line Engineer V I Chip Strategic Accounts Introduction Contents Page Introduction 1 The Importance of 1 Board Layout Low DC
Understanding Power Impedance Supply for Optimum Decoupling
Introduction Noise in power supplies is not only caused by the power supply itself, but also the load s interaction with the power supply (i.e. dynamic loads, switching, etc.). To lower load induced noise,
CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults
CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±6 Faults Ciaran Brennan design features The LTC2875 is a robust CAN bus transceiver that features ±6 overvoltage and ±25kV ESD tolerance to reduce
POWER LINE FILTERS FOR SWITCHING POWER SUPPLIES
POWER INE FITERS FOR SWITCHING POWER SUPPIES ing. Eugen COCA *, prof. dr. ing. Dimitrie AEXA ** * EECTRICA SA - SD SUCEAVA - ROMANIA ** U.T. Gh. Asachi IASI - ROMANIA * SEM0kV - PRAM str. Stefan cel Mare,
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
An Ethernet Cable Discharge Event (CDE) Test and Measurement System
An Ethernet Cable Discharge Event (CDE) Test and Measurement System Wei Huang, Jerry Tichenor ESDEMC Technology LLC Rolla, MO, USA [email protected] Abstract A Cable Discharge Event (CDE) is an electrostatic
Measuring Impedance and Frequency Response of Guitar Pickups
Measuring Impedance and Frequency Response of Guitar Pickups Peter D. Hiscocks Syscomp Electronic Design Limited [email protected] www.syscompdesign.com April 30, 2011 Introduction The CircuitGear
Application Note AN- 1095
Application Note AN- 1095 Design of the Inverter Output Filter for Motor Drives with IRAMS Power Modules Cesare Bocchiola Table of Contents Page Section 1: Introduction...2 Section 2 : Output Filter Design
Grounding of Electrical Systems NEW CODE: Grounding and Bonding
Grounding of Electrical Systems NEW CODE: Grounding and Bonding Presented By Scott Peele PE Grounding of Electrical Systems Outline Defining the Terms Why should I Ground? Types of Grounding Systems Separately
Power Quality Issues, Impacts, and Mitigation for Industrial Customers
Power Quality Issues, Impacts, and Mitigation for Industrial Customers By Kevin Olikara, Power and Energy Management Products Rockwell Automation, Inc. Now, more than ever, electronic equipment and computing
Troubleshooting accelerometer installations
Troubleshooting accelerometer installations Accelerometer based monitoring systems can be tested to verify proper installation and operation. Testing ensures data integrity and can identify most problems.
AN1826 APPLICATION NOTE TRANSIENT PROTECTION SOLUTIONS: Transil diode versus Varistor
AN1826 APPLICATION NOTE TRANSIENT PROTECTION SOLUTIONS: Transil diode versus A. BREMOND / C. KAROUI Since the seventies, electronic modules are more and more present in our life. This is the case for our
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
Video Camera Installation Guide
Video Camera Installation Guide The intent of this guide is to provide the information needed to complete or modify a video camera installation to avoid lightning and induced power surge damage. This guide
DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D
ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &
Bourns Resistive Products
Bourns Resistive Products Diverse Requirements Drive Innovations to Pulse Resistors Introduction Countless circuits depend on the protection provided by one of the most fundamental types of passive components:
Drive circuit basics + V. τ e. Industrial Circuits Application Note. Winding resistance and inductance
ndustrial Circuits Application Note Drive circuit basics For a given size of a stepper motor, a limited space is available for the windings. n the process of optimizing a stepper motor drive system, an
Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards
Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards Abstract This Guide is an informative listing of selected terms and definitions found in IEC Glossary entry
Electromagnetic (EMI) shielding
Electromagnetic (EMI) shielding 1.1. The mechanism of Electromagnetic Interference (EMI) The definition of EMC The council of the European Union defines EMC in Article 4 of their "council directive on
CHAPTER 6 INSTRUMENTATION AND MEASUREMENTS 6.1 MEASUREMENTS
CHAPTER 6 INSTRUMENTATION AND MEASUREMENTS 6.1 MEASUREMENTS Atmospheric electricity is a field that is very easy to get into because it does not require a large capital investment for measuring equipment.
Episode 126: Capacitance and the equation C =Q/V
Episode 126: Capacitance and the equation C =Q/V Having established that there is charge on each capacitor plate, the next stage is to establish the relationship between charge and potential difference
Lab E1: Introduction to Circuits
E1.1 Lab E1: Introduction to Circuits The purpose of the this lab is to introduce you to some basic instrumentation used in electrical circuits. You will learn to use a DC power supply, a digital multimeter
E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE
E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE References for Nuclear Magnetic Resonance 1. Slichter, Principles of Magnetic Resonance, Harper and Row, 1963. chapter
Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications
Product Overview Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications The 2Pro AC family of devices provide integrated overcurrent/overvoltage/ overtemperature
STRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
Load Dump Pulses According to Various Test Requirements: One Phenomenon Two Methods of Generation A Comparison
Load Dump Pulses According to Various Test Requirements: One Phenomenon Two Methods of Generation A Comparison Roland Spriessler 1, Markus Fuhrer 2, 1,2 EM Test, Sternenhofstrasse 15, CH-4153 Reinach (BL),
Diode Applications. by Kenneth A. Kuhn Sept. 1, 2008. This note illustrates some common applications of diodes.
by Kenneth A. Kuhn Sept. 1, 2008 This note illustrates some common applications of diodes. Power supply applications A common application for diodes is converting AC to DC. Although half-wave rectification
Circulating Current Relay. Type IRXm
Circulating Current Relay Type IRXm ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering
BASIC ELECTRONICS AC CIRCUIT ANALYSIS. December 2011
AM 5-202 BASIC ELECTRONICS AC CIRCUIT ANALYSIS December 2011 DISTRIBUTION RESTRICTION: Approved for Pubic Release. Distribution is unlimited. DEPARTMENT OF THE ARMY MILITARY AUXILIARY RADIO SYSTEM FORT
High Voltage Power Supplies for Analytical Instrumentation
ABSTRACT High Voltage Power Supplies for Analytical Instrumentation by Cliff Scapellati Power supply requirements for Analytical Instrumentation are as varied as the applications themselves. Power supply
Transient Overvoltage Protection
TND335/D Rev. 0, APR - 2008 Transient Overvoltage Protection Semiconductor Components Industries, LLC, 2008 April, 2008 - Rev. 0 1 Publication Order Number: TND335/D Chapter 1. The Nature of the Transient
Nexus Technology Review -- Exhibit A
Nexus Technology Review -- Exhibit A Background A. Types of DSL Lines DSL comes in many flavors: ADSL, ADSL2, ADSL2+, VDSL and VDSL2. Each DSL variant respectively operates up a higher frequency level.
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
Transient and Lightning Protection for the Water Industries
Transient and Lightning Protection for the Water Industries Mike Nager Phoenix Contact [email protected] 5 th ISA Water/Wastewater Automatic Controls Division Symposium (WWAC) August 3-5, Orlando,
1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.
CHAPTER 3: OSCILLOSCOPE AND SIGNAL GENERATOR 3.1 Introduction to oscilloscope 1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal. 2. The graph show signal change
Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012
Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012 CHANGE CONTROL RECORD: Version Date Action* Reason for Revision
Introduction. Harmonics and IEEE 519 Page 1 of 19
Introduction In an ideal power system, the voltage supplied to customer equipment, and the resulting load current are perfect sine waves. In practice, however, conditions are never ideal, so these waveforms
Conducted EMI filter design for SMPS
Conducted EMI filter design for Jukka-Pekka Sjöroos Helsinki University of Technology Power Electronics Laboratory Conducted EMI filter design for Introduction EMI in Common Mode(CM noise Differential
EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT
EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT 4 Understand single-phase alternating current (ac) theory Single phase AC
SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS
SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE S By Jack Farrow, May, 2004 WELDING TECHNOLOGY CORPORATION ABSTRACT Information on how to select the correct size of substation transformer and 480V bus to
)454 6 %LECTRICAL CHARACTERISTICS FOR BALANCED DOUBLECURRENT INTERCHANGE CIRCUITS OPERATING AT DATA SIGNALLING RATES UP TO -BITS
INTERNATIONAL TELECOMMUNICATION UNION )454 6 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/96) SERIES V: DATA COMMUNICATION OVER THE TELEPHONE NETWORK Interfaces and voiceband modems %LECTRICAL CHARACTERISTICS
Signal Integrity: Tips and Tricks
White Paper: Virtex-II, Virtex-4, Virtex-5, and Spartan-3 FPGAs R WP323 (v1.0) March 28, 2008 Signal Integrity: Tips and Tricks By: Austin Lesea Signal integrity (SI) engineering has become a necessary
LIN-bus ESD protection diode
Rev. 3 31 May 2011 Product data sheet 1. Product profile 1.1 General description in a very small SOD323 (SC-76) Surface-Mounted Device (SMD) plastic package designed to protect one automotive Local Interconnect
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60071-2 Third edition 1996-12 Insulation co-ordination Part 2: Application guide This English-language version is derived from the original bilingual publication by leaving out
EE 1202 Experiment #4 Capacitors, Inductors, and Transient Circuits
EE 1202 Experiment #4 Capacitors, Inductors, and Transient Circuits 1. Introduction and Goal: Exploring transient behavior due to inductors and capacitors in DC circuits; gaining experience with lab instruments.
WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.
WHY DIFFERENTIAL? Voltage, The Difference Whether aware of it or not, a person using an oscilloscope to make any voltage measurement is actually making a differential voltage measurement. By definition,