RPF-Series Radial-Flow Side-Access Bag-In/Bag-Out Filter Housings

Size: px
Start display at page:

Download "RPF-Series Radial-Flow Side-Access Bag-In/Bag-Out Filter Housings"

Transcription

1 RPF-Series Radial Flow Filter Housing PB RPF-Series Radial-Flow Side-Access Bag-In/Bag-Out Filter Housings High-Efficiency Air Filtration Products and Services for Control of Gaseous and Particulate Contaminants A Wholly Owned Subsidiary of Flanders Corporation

2 Quality Assurance Any industry that has dangerous process or exhaust gases and/or particulates has a vital concern for the health and safety of personnel. In addition to corporate concern, the United States Government has dictated that safety equipment meet minimum safety standards. Any equipment sold to meet these minimum standards has to be manufactured using accepted Quality Control procedures. Flanders/CSC Corporation has developed a Quality Assurance program to assure that the product or service provided meets these standards. This program addresses the entire range of Flanders/CSC involvement, including the purchase of raw materials, the shortage of these raw materials, incorporation of these materials into a product or service, testing this product or service, and then shipping it to its destination. The program of Flanders/CSC has been audited many times, and each time the program has been acceptable. An uncontrolled copy of the program manual is available with each request for Quality Assurance information. Like any dynamic document, the program is continually being revised to include recent issues of standards and specifications in order that Flanders/CSC may use the latest state-of-the-art methods in providing its products and services. The Quality Assurance Program at Flanders/ CSC Corporation has been audited and approved several times by the Nuclear Utilities Procurement and Inspection Committee, NUPIC. This committee was established by nuclear electric utilities to ensure that suppliers of goods and services can meet all applicable regulatory and quality requirements. Notes: 1 As part of our continuing program to improve the design and quality of all our products, we reserve the right to make such changes without notice or obligation. 2 Flanders/CSC, through its limited warranty, guarantees that the products described herein will meet all specifications agreed to by the buyer and the seller. 3 ASME N509 Nuclear Power Plant Air- Cleaning Units and Components. 4 ASME N510 Testing of Nuclear Air Treatment Systems. 5 ASME AG-1 Code on Nuclear Air and Gas Treament Copyright 2005 Flanders/CSC Corporation 7013 Hwy 92E - PO Box 3 Bath, NC 27808

3 RPF Radial Flow Side-Access Filter Housing: Table of Contents Quality Assurance Inside Front Cover Table of Contents Important Message Introduction Safety Construction Details and Options Blu-Jel â Seal Temperature Rating Housing Material Door Latches Bag-In/Bag-Out Port Security Strap Pressure Rating Leak Testing Door Gasket Cinching Strap Elastic Shock Cord PVC Change-Out Bag Filter Clamps Baffle Plenum Leak Testing Quality Control/ Quality Assurance Engraved ID Label Filter Change-Out Concepts Construction Details Static Pressure Taps Test Ports Moisture Drains and Valves Low Leak Test High Pressure Design Banding Kit Plenums, Transitions, Dampers Flanges Radial Flow HEPA Filters Seismic Qualifications Ordering Information Suggested Specifications Options Standard Options

4 RPF Radial Flow Side-Access Filter Housing: Important Message Important Message NOTICE... Compliance with installation and operation standards must be met to ensure quality performance. HEPA filters are factory tested to meet the requirements of IEST RP-CC001.3 for Type A, B, C, D, E or F filters: Industrial Grade Nuclear Grade Laminar Flow Grade Bio/Hazard Grade HEPA VLSI ULPA Pharmaceutical Grade Test results appear on both the filter label and upon the filter carton label. An additional quality assurance test report is kept on file and is available upon request. Flanders recommends that all HEPA filters be tested in place by qualified personnel to ensure that the filters have been correctly installed. Flanders service personnel are available for installations, supervision of installation, testing and certification of compliance to industry and government standards and instruction of the owner s personnel in testing and maintenance procedures. Flanders does not guarantee that its equipment will operate at the performance levels given on the identification labels or in the catalog specifications under all conditions of installation and use, nor does Flanders/CSC guarantee the suitability of its product for the particular end use which may be contemplated by the buyer. For best results, it is recommended that the buyer supply complete information about the operating conditions of the ventilation system to Flanders/CSC for evaluation. When the system components are supplied to the buyer or his agent for final installation and assembly in the field, it should be under the supervision of factory trained personnel. Failure to adhere to this recommendation or failure of the buyer to have filters timely retested and serviced will nullify or limit any warranties which might otherwise apply and may result in a compromised installation. 2

5 RPF Radial Flow Side-Access Filter Housing: Introduction Flanders/CSC Containment Housings: RPF-Series Bag-In/Bag-Out Housing The RPF-Series Gel Seal containment housings are typically used on critical processes where dangerous airborne particulate must be prevented from entering the atmosphere. The Flanders/CSC RPF-Series bag-in/bag-out filter housing allows for the installation of radial flow HEPA filter elements in a low CFM ventilation system (e.g. glovebox, isolator). The RPF-Series filter housings are designed for particulate filtration. One of the primary uses of HEPA filters is the containment of toxic materials. When filters become contaminated in-service with these materials, a method for their removal without direct operator contact is necessary. The bag-in/bag-out feature of the RPF- Series allows the operator to change filters without coming into direct contact with the toxic materials (such as viable organisms, radioactive dust and carcinogens) that have been collected by the filter element during its service life. RPF-Series Bag-In/Bag-Out: The RPF-Series housing features a side access bag-in/bag-out port which allows filters that have been contaminated in service to be removed from the housing without direct contact with service personnel. Basic housings are available in 1H1W, 2H1W and 3H1W configurations, allowing filters to be removed from separate access door. Units may be joined to build systems with capacities ranging from 1,000 CFM to 60,000 CFM (based upon 2,000 CFM per filter). Many custom options are available, including static pressure taps, test ports, transitions, dampers and in-place test sections which allow the operator to perform filter system efficiency test without having to enter the system or otherwise disrupt its operation. The RPF-Series bag-in/bag-out housing is a side servicing filter housing that has been designed to meet the air filtration needs of industries and research facilities that handle dangerous or toxic biological, radiological or carcinogenic materials. To minimize exposure to harmful contamination while replacing and handling dirty filters, the RPF- Series housing incorporates a ribbed bagging ring behind the access door, over which a PVC bag is attached. Once the initial filters are installed and the first bag is attached, all filters, both dirty and new, are handled through the bag. These procedures are summarized on Page 9. Manufactured under stringent quality assurance controls, RPF-Series housings are subjected to thorough inspections and leak tightness tests before leaving the factory, and are guaranteed to pass DOP in-place tests. This guarantee is contingent upon the use of properly installed Flanders Radial Flow HEPA filters. 3

6 RPF Radial Flow Side-Access Filter Housing: Safety Safety Comes First The Flanders/CSC reputation for excellence in the design and fabrication of critical air filtration systems is the result of decades of attention to the toughest environmental and safety standards in the world. Throughout the long development of the RPF-Series containment...from the Leader in Air Filtration Technology. housing, safety has been the first design priority and our track record reflects the confidence of our customers. Flanders/CSC containment systems are operating in hundreds of sites, including: Hospital Isolation Suites Pharmaceutical Facilities Microelectronic Sites Food Processing Areas Genetic and Biotech Labs University Campuses Industrial Process Exhaust Systems Chemical Process Facilities Animal Disease Labs Radioisotope Handling Facilities Nuclear Power Plants Strategic Nuclear Facilities HVAC Systems Department of Energy Facilities 4

7 RPF Radial Flow Side-Access Filter Housing: Construction Details â Blu-Jel Seal The filter-to-housing fluid seal is effected between the housing and the filter by means of a circular knife edge in the housing. The knife edge mates into a channel on the upstream end of the filter. The channel is filled with a viscous non-drying sealing compound. AIR FLOW Metal Grill Filter Pack Housing Material The standard RPF-Series filter housing is constructed from 14 and 11 gauge Type 304 stainless steel. Housings are also available in Type 304L, 316, and 316L construction. Some hardware on the housing will be 300 series stainless steel. All pressure retaining joints and seams are welded airtight per ASME Section IX, with no visible pores. All welds shall be free of burrs and sharp edges. Door Latches A minimum of four tie-down latches are provided per access door. The latches pivot away from the bag-in/bag-out port after release so they do not impede the bag-in/bag-out process. The knob of the door latch is designed to spin free for door removal. Figure 2: Radial Flow HEPA â See Figure 3 for Blu-Jel Seal Knife Edge Filter Pack Door Latch Open â Blu-Jel Filled Channel Figure 3: Blu-Jel Seal Metal Grill Temperature Rating The standard housing is rated for degrees F. High temperature bags, straps, and gaskets are available to go up to 400 degrees F. Door Latch Closed 5

8 RPF Radial Flow Side-Access Filter Housing: Construction Details Bag-In/Bag-Out Port The housing s bag-in/bag-out port is designed so that a heavy duty PVC bag can be securely fastened around it after the original filter has been installed. When the door is eventually removed to change the filter, the bag provides a barrier between the operator and the contaminated filter. When the door is closed, the bag remains inside the door., The RPF-Series change-out port, accessed by the door removal, has two (2) ribs on the bagging ring to facilitate the bag-in/bag-out procedure. Bagging Ring Figure 4: Bagging Ring 6 Shock Cord 2nd Rib Change-Out Port Bagging Ring Housing 1st Rib Bag Security Strap Security Strap A one-inch wide nylon security strap provided with each RPFSeries filter housing fits around the lip of the bag-in/ bag-out port, in between the two ribs and over the âmouth of the bag. This supplements the elastic band in the bag and helps reduce the possibility of the bag pulling away from the lip in case the filter is accidentally dropped during replacement. The strap is buckled with a D ring and has Velcro strips to secure the end. Pressure Rating Security Strap The standard housing is rated at positive and negative 20-inch water gage. Reinforcement can be added to reach higher pressures. Leak Testing The complete assembly pressure boundary is leak tested by the Pressure Decay Method, in accordance with ASME N Reaffirmed, Testing of Air-Cleaning Systems, Paragraphs 6 and 7. Readings are recorded once a minute for five (5) minutes. Flanders/CSC s standard acceptable maximum leak rate is CFM per cubic foot of housing volume at the design pressure for the housing pressure boundary. Door Gasket The door of the RPF-Series is sealed to the housing by means of a replaceable extruded closed-cell neoprene gasket adhered to the lip of the door. The gasket is designed to be field replaceable if needed.

9 RPF Radial Flow Side-Access Filter Housing: Construction Details Silicone gaskets are available as an option. PVC Change-Out Bag A PVC bag is included with each access door. The Flanders/CSC change-out bag is translucent and yellow in color with a clear section at the attachment end for change-out viewing. Door Gasket Cinching Strap A cinching strap is provided with each bag to tie off the slack in the bag during the interval between filter changes. The cinching strap prevents the bag from being drawn into the housing during normal operations. The strap is cinched at a point near the lip of the bag-in/bagout port, drawing the bag tightly across the port and allowing the slack to fall off to the outside. The slack is then folded flat and contained inside the door. Elastic Shock Cord An elastic shock cord is hemmed into the mouth of the bag for a firm fit when stretched around the bagging ring. The bag has three (3) built-in glove sleeves to facilitate the filter change out. Correct replacement bag sizes are engraved on the door label of each housing. Replacement bag size labels are also attached to the shock cord hemmed into the bag mouth. PVC bags of this design have been tested by an independent laboratory to prove the bag s operability at extreme temperature ranges of 0 F 130 F. Elastic Shock Cord Security Strap, Cinching Strap, PVC Change-Out Bag Replacement Bag Size Labels on Shock Cord 7

10 RPF Radial Flow Side-Access Filter Housing: Construction Details Filter Clamps A stainless steel filter clamp secures the filter during operation. The clamps are spring-loaded and have a rod handle that is turned 90 degrees by the operator to lock the filter in the sealed position. The filter clamping design is a variation of ASME AG-1 Section HA. AG-1 Section HA currently does not address radial flow filter housings: it is written for axial flow filter housings. The filter clamping design ensures Jel Seal filters are properly seated, but does not pull the filter off of the surface stated for axial flow filters. Baffle Plenum 8 Filter Clamps The RPF-Series housing features a permanently welded baffle plenum. The air entering the housing is diverted before reaching the radial flow filter element. Leak Testing Both the filter sealing surface and the complete assembly pressure boundary are leak tested by the Pressure Decay Method, in accordance with ASME N Reaffirmed, Testing of Nuclear Air Treatment Systems, paragraphs 6 and 7. Readings are recorded once a minute for 5 minutes. The maximum allowable leak rate for the filter-sealing surface is CFM per cubic foot of housing volume when tested at 10 inches water gage. The maximum allowable leak rate for the housing pressure boundary is CFM per cubic foot of housing volume when tested at 10 inches water gage. Quality Assurance/ Quality Control Quality Control/ Quality Assurance Flanders/CSC products are manufactured under a strict QA program that is highly respected throughout our industry. Our QA program incorporates quality control checks from receipt of materials through final clean up and packaging. Our shop process is set up to easily incorporate customer specified checks into our QC program. Engraved ID Label To facilitate reordering of critical replacement parts and components, each housing has a stainless steel label permanently engraved with the following information: manufacturer s name housing model number filter model number (or filter size) change-out bag number manufacturer s order number other pertinent data (when specified)

11 RPF Radial Flow Side-Access Filter Housing: Bag-In/Bag-Out Process Filter Change-Out Concept RIBBED BAING RING RADIAL HEPA FILTER SECURITY STRAP BAG STUB REMOVAL GLOVE SLEEVE CHANGE-OUT BAG (PLASTIC) FILTER HANDLING GLOVE SLEEVE CINCHING STRAP ACCESS DOOR Note: A complete step-by-step change-out instruction manual is furnished with each housing or system. The illustrations below are the basic steps involved in changing contaminated filters in a Bag-In/Bag-Out containment housing. A complete step-by-step change-out instruction manual is furnished with each housing or system. Access Door PLASTIC CHANGE-OUT BAG ACCESS DOOR Plastic Change-Out Bag AccessDoor Closed Figure Plastic Change-Out Bag Extended Bag Figure Remove access door. Extend bag and place arms in filter handling glove sleeves of bag. 9

12 RPF Radial Flow Side-Access Filter Housing: Construction Details Figure 3 Release filter locking mechanism. Rotate away from filter. Carefully draw contaminated filter into bag and place filter (in bag) on stand or table. Remove arms from bag. Figure 6 Remove bag stub using bag stub removal glove sleeve of the new bag. Draw stub into sleeve by turning sleeve inside out. Install new filter using glove sleeves. Seal and detach bag stub/glove sleeve. Figure 4 Seal bag between access ring and filter. (See banding kit instruction manual.) Sever bag, leaving bag stub attached to access ring. Figure 5 Place new filter into a new bag. Place new bag over bag stub attached to access ring. 10 Figure 7 Fold new bag inside bag-in/bag-out ring and replace access door.

13 RPF Radial Flow Side-Access Filter Housing: Construction Details Static Pressure Taps Static pressure taps allow the measurement of differential pressure across the filter. Taps consist of stainless steel 1 /4 inch half-couplings with brass plugs, and are located on the inlet and outlet connections of the housing. DOP Test Ports To allow in-place efficiency testing of the installed filter, a DOP injection port ( 3 /4 inch coupling with brass plug) is located on the inlet side of the housing. Sample ports ( 3 /8 inch couplings with brass plugs) are located upstream and downstream of the filter. Moisture Drains and Valves For applications with a potential for moisture condensation, an optional drain valve assembly is available. This assembly consists of a stainless steel 1 /2 inch half-coupling, close nipple, with a stainless steel ball valve and brass plug. When moisture drain valves are provided, it is recommended that a mounting base be used. Low Leak Test The Low Leak Test required in the Nuclear Air Cleaning Handbook, ERDA (Table 4.5) is offered as an alternative to the standard leak test. It is a considerably more stringent test, allowing a leak rate of no more than 0.2% of the housing volume per hour at a pressure of 10 inches water gage. This equates to CFM per cubic foot of housing volume. High Pressure Design Flanders/CSC can design special high-pressure RPF Series housings capable of pressures up to 15 PSI positive or 14.7 PSI negative. Welds are performed per ASME Section IX. Banding Kit The Flanders/CSC banding kit facilitates clamping off the bag between the housing and the spent filter. The kit contains a supply of 25 stainless steel bands and the tools necessary to perform banding operation. An instruction/ procedure manual is included in the banding kit. The kit provides a simple, but extremely effective barrier during filter change-out. Figure 5: Drain Valve Banding Kit 11

14 RPF Radial Flow Side-Access Filter Housing: Construction Options Plenums, Transitions and Dampers Airflow control can be achieved by incorporating plenums, transitions and dampers. Flanders/ CSC can fabricate these components as an integral part of the system meeting the owner s site requirements. Dampers are available in a variety of designs Contact the factory for details. Flanges Flanges are available for bolting the inlet and outlet connections to the ventilation system. Available in ¼ thick stainless steel fabricated plate flange, or 150 lb. class stainless steel in standard NPS sizes. Special sizes and types are also available. Radial Flow HEPA Filters Radial Flow HEPA Filters are 99.97% efficient at 0.3 µ as tested on a Q107 penetrometer in accordance with MIL STD 282 at 100% and 20% of rated flow. The filter media is Flanders proprietary Dimple Pleat that is formed from a continuous sheet. Pleat alignment and spacing is maintained through the formation of the media such that no additional separator material is required. The pleated media is rolled into a cylinder and sealed into stainless steel end caps with solid polyurethane, along with a protective screen. Seismic Qualifications Seismic qualification can be provided on the RPF-Series. The owner or design engineer should contact the factory with design requirements and specifications to insure that the manufacturer s test results are in accordance with the seismic loading requirements of the owner s facility and plant site. The following information is required before Flanders/CSC can provide a quotation: design specifications and author project name project location required acceleration levels required response spectra curves Radial Flow HEPAs 99.97% on 0.3 micron size particles 12

15 RPF Radial Flow Side-Access Filter Housing: Ordering Information H W D Model No. RPF1-Series Data Chart H W L inches inches inches RPF1-E / 16 RPF1-F / 16 RPF1-H / 16 RPF1-K / 16 RPF1-M / 16 RPF1-N / 16 RPF1-Q / 16 Model No. Rated Flow Filter Size Est. Housing Wt CFM inches (nominal) lbs RPF1-E O. D. x 8 3 /4 L. 100 ** RPF1-F O. D. x 12 3 /4 L. 100 ** RPF1-H O. D. x 10 L. 150 ** RPF1-K O. D. x 19 L. 150 ** RPF1-M O. D. x 14 L. 200 ** RPF1-N O.D. x 16 L. 200 ** RPF1-Q O.D. x 21 L. 200 ** ** Estimated weight will vary depending on inlet / outlet size and style and other options. 13

16 RPF Radial Flow Side-Access Filter Housing: Ordering Information Model Number Example: Housing Series Radial Flow Plenum Fluid Seal First Generation RPF1-2H2W - Q Number of Filters High 1H = One Filter High 2H = Two Filters High 3H = Three Filters High 4H = Four Filters High Number of Filters Wide 1 W = One Filter Wide 2 W = Two Filters Wide 3 W = Three Filters Wide Size Designator of Primary Filter E = 8 outer dia. x 8 3 /4 length F = 8 outer dia. x 12 3 /4 length H =16 outer dia. x 10 length K =16 outer dia. x 19 length M =16 outer dia. x 14 length N =20 outer dia. x 16 length Q =20 outer dia. x 21 length Housing Construction Material 304 = Type 304 SST (Standard) 304L = Type 304L SST 316 = Type 316 SST 316L = Type 316L SST 14

17 RPF Radial Flow Side-Access Filter Housing: Suggested Specifications Suggested Specifications: RPF1 Housings (Jel Seal) The filter housing shall be Flanders/CSC RPF- Series housing designed to accommodate radial flow HEPA filters. The housings shall be manufactured per the requirements of ASME AG-1 as stated herein. The housing shall be bag-in/bagout design and shall be manufactured from 14 and 11 gauge type 304 stainless steel. The housing shall be adequately reinforced to withstand a negative or positive pressure of twenty (20) inches water gage. The design and filter arrangement shall be a side servicing bank that will allow air to enter and exit the housing without changing directions. To accommodate jel seal radial flow HEPA filters, the housing shall incorporate a round knife edge that mates into the jel filled perimeter channel on the face of the filter. Access to the filter shall be from the side of the housing. Prior to leaving the factory, each knife edge shall be checked with an alignment gage to insure proper engagement with the filter. The filter shall be held in place by a spring loaded filter sealing clamp. The filter sealing clamp shall be designed to operate through the changeout bag and shall have a positive stop in the sealed position. The clamps shall be constructed of 300 series stainless steel. All change-out operations shall be within the bag so there is a barrier between the worker and the filter at all times. All pressure retaining weld joints and seams shall be continuously welded with no pores allowed. Joints and seams requiring only intermittent welds, such as reinforcement members, shall not be continuously welded. As a minimum, joints and seams shall be wire brushed and/or buffed to remove heat discoloration, burrs and sharp edges. All weld joints and seams that are a portion of any gasket sealing surface (e.g., filter seal surface, duct connecting flanges) shall be ground smooth and flush with the adjacent base metal. The upstream and downstream flanges shall have a 1 1 /2-inch minimum flange width. Flanges shall be turned to the outside of the airstream to prevent contamination buildup and allow the customer to connect mating ductwork from outside the housing. All welding procedures, welders and welder operators shall be qualified in accordance with ASME Boiler and Pressure Vessel Code, Section IX. All production welds shall be visually inspected per Flanders/CSC Standard Procedure Number P-122, Visual Inspection of Welds, which incorporates the workmanship acceptance criteria described in Sections 5 and 6 of ANSI/AWS D , Specifications for Welding Sheet Metal. All hardware on the housing and all mechanical components of the filter sealing mechanism shall be Type 300-Series stainless steel, except for the cast aluminum access door knobs. The housing shall have a bagging ring around each filter access port. The bagging ring shall have two (2) continuous ribs to secure the PVC change-out bag. The outer edge of the ring shall be hemmed to prevent the bag from tearing. Each access port and bagging ring shall be covered by a door having an extruded neoprene gasket that is manually replaceable after the door has been removed. When closed, the door shall not press against the bag-out port and PVC bag, thus eliminating the possibility of damage to the bag. One (1) PVC change-out bag shall be furnished for each filter access port. Each bag shall have the stock number rolled into the hem. The PVC bag material shall be eight (8) mil thick, yellow in color, with a translucent taffeta texture finish and shall not stick together. For visibility during change-out, the bag shall include approximately 16 inches of clear PVC at the mouth. Three (3) glove sleeves shall be built into the bag to facilitate handling of the filter during change-out. PVC bags of this design shall have been tested by an independent laboratory to prove the bag s operability at extreme temperature ranges of 15

18 RPF Radial Flow Side-Access Filter Housing: Suggested Specifications 0 F 130.F (A test report verifying this testing shall be furnished upon request.) The elastic shock cord shall be hemmed into the mouth of the bag so that it fits securely when stretched around the bagging ring. To prevent the bag from sliding off the bagging ring during change-out operation, one (1) nylon security strap shall be provided with each filter access port. A nylon cinching strap shall also be provided with each access port to tie off the slack in the bag while the ventilation system is operating. The filter housing shall be manufactured under a quality assurance program that meets all the basic requirements of ASME NQA-1, Quality Assurance Program Requirements for Nuclear Facilities. The manufacture shall submit documented evidence they have been independently audited by customers at least three (3) times within the last six (6) years to ASME NQA-1 requirements, and successfully passed all three (3) audits. The housing shall be tested for filter fit, operation of the filter clamping mechanism, knife edge alignment and leak tightness before leaving the factory. The final containment filtration system shall be completely fabricated, assembled, tested and cleaned at the manufacturers facility. Subassemblies from outside sources will not be acceptable. Both the filter sealing surface and the complete assembly pressure boundary shall be leak tested by the Pressure Decay Method, in accordance with ASME N Reaffirmed, Testing of Air Cleaning Systems, Paragraphs 6 and 7. Pressure readings are recorded once a minute for five (5) minutes. There shall be a maximum leak rate of CFM per cubic foot of housing volume at ten (10) inches water gage. A minimum of four (4) feet clearance in front of the filter access door is suggested for filter change-out. 16 Notes:

19 RPF Radial Flow Side-Access Filter Housing: Options RPF-Series Standard Options Static Pressure Taps Pressure Gages 300-Series SST Gage Fittings and Tubing DOP Test Ports Lifting Lugs Swivel Door Latches Weather Caps Bead Blast Finish Transitions Isolation Dampers In-Place Test Housings Metal Door Pocket Additional PVC Bags Additional Security Straps Additional Cinching Straps Filter Removable Tray Banding Kit Moisture Drains and Valves Drilled Flanges RPF-Series Available Options Certified Weld Inspection (CWI) Liquid Dye Penetrant Testing Special Low Leakage Testing High/Low Pressure Design Deformation Testing Decontamination Ports All Stainless Steel Locking Mechanisms 1/4 inch Plate Flanges 150# Class Slip-on Flanges Plenums Mounting Bases High Temperature Design Seismic Design Acid Resistant Materials Special Polished Finishes Insulation Silicone Door Gasket 17

20 RPF Radial Flow Side-Access Filter Housing: Standard Options Magnehelic Gages Flanders/CSC can provide differential pressure gages factory mounted with brass fittings and copper tubing. Optional 300-Series stainless steel fittings and tubing are available as an option. Factory installed gages are mounted on brackets for systems indoors or outdoors. Factory installed gages have 300-Series stainless steel identification labels stitch welded to the mounting bracket. Photohelic gages are mounted in a covered panel for outdoor installation. These gages can also be provided (unmounted) as separate items. 18 Magnehelic Gages Static Pressure Taps Static pressure taps are 1/4 inch stainless steel half couplings with brass hex plugs. The taps can be located on the top or the back of the housing upstream and downstream of the prefilters and/or HEPA filters. The customer should specify the quantity and arrangement of the taps across the filters. Static Pressure Taps are 1 /4 inch Stainless Steel Half-Coupling with Brass Hex Plugs Test Ports Test ports are stainless steel 3 /8 inch half couplings with brass hex plugs located on the door access side of the housing for upstream sampling. A DOP upstream injection port and downstream sample port may also be supplied for installation by others in the owner s ductwork. Note: The upstream DOP injection port and the downstream sample port should be located at least ten (10) duct diameters upstream and downstream (respectively) of the filter bank. These additional ports must be requested and will be shipped loose. Transitions Customer ductwork connections can be joined by incorporating transitions, plenums and dampers. Flanders/CSC can fabricate these Ductwork Connections components as an integral part of the system, meeting the owners specific requirements. These options will be manufactured and tested with the same stringent requirements of the containment housings. Isolation Damper Flanders/CSC manufactures low-leakage and bubble-tight dampers for effective shut-off and isolation of containment. Note: Damper bulletins are available upon request. Contact Flanders/CSC or your local representative for complete details. Filter Removal Tray Damper The filter removal tray fits onto standard housings to provide support for the filter or adsorber that is being changed out, as well as for the replacement filter. It is especially recommended for the safe removal of heavy carbon adsorbers, and for any housings over two (2) filters high. The customer must specify standard or pivot type door latches to receive the correct tray.

21 RPF Radial Flow Side-Access Filter Housing: Standard Options Drilled Duct Connection Flanges Drilled Flange Measurement Chart Housing Size W Width A Horizontal Spaces No. of Spaces (A) Between Corner Holes 1H1W CC 1H1W CG 1H1W GC /8 3 41/64 3 3/ Drilled Flanges Factory drilled bolt holes for duct connections are available. Flanders/CSC has established bolt hole patterns for each model size housing in the B-Series and K-Series, from the 1H1W housing to the 4H3W housings. Holes are drilled 7/16 inch diameter with spacing between holes no more than four (4) inches apart, as recommended in ERDA Nuclear Air Cleaning Handbook. Flanges can also be reinforced to 1/4 inch thickness to create a stronger flange connection. See the Measurement Charts for various bolt hole pattern dimensions. H Height B Vertical Spaces No. of Spaces (B) Between Corner Holes / /64 3 9/ Note: All dimensions are given in inches. 19

22 RPF Radial Flow Side-Access Filter Housing: Standard Options Lifting Lugs Listing lugs of 1 /4 inch thick Type 304 stainless steel with a 1 1 /2 inch diameter listing lug can be welded to the top or side of the housing. Lifting Lug Housing Size W Width A Horizontal Spaces No. of Spaces (A) Between Corner Holes 1H1W 1H2W 1H3W 2H1W Drilled Flange Measurement Chart 2H2W 2H3W 3H1W 3H2W 3H3W 4H1W 4H2W H3W 3 41/ / / / / / / / / / / / H Height B Vertical Spaces No. of Spaces (B) Between Corner Holes /16 3 9/16 3 9/ / / / / / / / / / Note: All dimensions are given in inches. 20

23 Important Notice For best results in the application of Flanders/CSC â products, it is recommended that the buyer supply complete information about the operating conditions of the ventilation system to Flanders/CSC â for prior evaluation. Flanders/CSC â does not guarantee that its equipment will operate at the performance levels given on the identification labels or in the catalog specifications under all conditions of installation and use, nor does Flanders/CSC â guarantee that suitability of its product for the particular end use which may be contemplated by the buyer. When the system components are supplied to the buyer or his agent for final installation and assembly in the field, it should be under the supervision of factory trained personnel who are equipped to test the installation and certify its performance and conformance to industry accepted specifications. Failure to follow these procedures may result in a compromised installation. FLANDERS/CSC â CORPORATION 7013 Hwy 92E - PO Box 3 Bath, NC Representatives of Flanders/CSC â products are located throughout the world. Your closest representative s office may be found by contacting our manufacturing and sales department. Represented by: Tel: Fax: [email protected] Web site: FLANDERS/CSC â Printed in USA 3/2005

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment. SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Installer s Guide 18-AH39D1-13

Installer s Guide 18-AH39D1-13 18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system Design Information Designing Your Dust Collection System There are five simple steps to designing an effective and efficient dust collection system. 1. Draw a floor plan of your shop Important Terms to

More information

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING 60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed

More information

INSTALLATION, OPERATION & MAINTENANCE Fan Filter Units CRFF, CRFF-ARS, & CRFF-ARSM PSC Motors. Revision: 10.01.13

INSTALLATION, OPERATION & MAINTENANCE Fan Filter Units CRFF, CRFF-ARS, & CRFF-ARSM PSC Motors. Revision: 10.01.13 INSTALLATION, OPERATION & MAINTENANCE Fan Filter Units CRFF, CRFF-ARS, & CRFF-ARSM PSC Motors Revision: 10.01.13 Page: 2 of 12 Critical operation conditions of the CRFF, CRFF-ARS and CRFF-ARSM 1. Touching

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

TYPE E Main Valve Sizes 3 /8 through 12

TYPE E Main Valve Sizes 3 /8 through 12 SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,

More information

Packaged Terminal Air Conditioner Wall Sleeve Installation

Packaged Terminal Air Conditioner Wall Sleeve Installation Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation

More information

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family

More information

Rental Services Temporary Cooling - Flexible Water Hose

Rental Services Temporary Cooling - Flexible Water Hose Engineering Bulletin Rental Services Temporary Cooling - Flexible Water Hose September 2006 CHS-PRB007-EN Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate

More information

Installation Instructions

Installation Instructions Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step

More information

SELF-STEERING AXLE TABLE OF CONTENTS

SELF-STEERING AXLE TABLE OF CONTENTS SELF-STEERING AXLE TABLE OF CONTENTS Section 1 - Introduction Section 2 - Pre-Installation Check List Section 3 - Ride Height Adjustments Section 4 - Suspension Mount Section 5 - Axle Mount Section 6 -

More information

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health Background Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health This document provides guidelines for the design and installation of Class

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve

More information

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi Pipe Valves, Fittings and Nipples MAXIMATOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed by

More information

Cabinets 101: Configuring A Network Or Server Cabinet

Cabinets 101: Configuring A Network Or Server Cabinet Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What

More information

Installation Instructions For Slider Casement Air Conditioners

Installation Instructions For Slider Casement Air Conditioners Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT

More information

HYDRAULIC LIFT TABLE CART 2200-LB.

HYDRAULIC LIFT TABLE CART 2200-LB. HYDRAULIC LIFT TABLE CART 2200-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other

More information

AIR CONDITIONING PRODUCTS COMPANY

AIR CONDITIONING PRODUCTS COMPANY Quality Products Fixed Louvers AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass Shutter

More information

MC² Market & Competitive Convergence Air Filters: New Facilities, New Standard

MC² Market & Competitive Convergence Air Filters: New Facilities, New Standard MC² Market & Competitive Convergence Air Filters: New Facilities, New Standard Advances in testing procedures, coupled with greater pressure for better IAQ, leads to a new standard By Ron Wilkinson, P.E.

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

UV100A Ultraviolet Air Treatment System

UV100A Ultraviolet Air Treatment System UV100A Ultraviolet Air Treatment System INSTALLATION INSTRUCTIONS APPLICATION When installed in forced air heating and cooling systems, the UV100A Ultraviolet Air Treatment System kills airborne microorganism

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Chemical Fume Hoods. Environmental Health and Safety 974-5084

Chemical Fume Hoods. Environmental Health and Safety 974-5084 Chemical Fume Hoods Environmental Health and Safety 974-5084 Regulatory References Prudent Practices in the Laboratory 2011 (National Research Council of The National Academies): Laboratory chemical hoods

More information

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-

More information

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation

More information

SECTION 6. Glass Storefront Doors:

SECTION 6. Glass Storefront Doors: SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail

More information

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks TITAN pt. no.: 03 0000 0120 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

4 Installation Requirements

4 Installation Requirements 4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming

More information

Black Wolf POCKET BILLIARD TABLE INSTALLATION MANUAL. SERVICE DEPARTMENT P.O. BOX 68 BRISTOL, WI 53104

Black Wolf POCKET BILLIARD TABLE INSTALLATION MANUAL.  SERVICE DEPARTMENT P.O. BOX 68 BRISTOL, WI 53104 Black Wolf TM POCKET BILLIARD TABLE INSTALLATION MANUAL www.brunswickbilliards.com SERVICE DEPARTMENT P.O. BOX 68 BRISTOL, WI 53104 51-905710-000 SEPTEMBER 2010 NOTE: Please use the instructions in this

More information

SECTION 15140 - PIPE HANGERS AND SUPPORTS

SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification Number: 3503-11.2.610 Rev. 2 Rubber Lined Steel Pipe and Fittings Mechanically Coupled Plain End Type System Issued Revised Approved

More information

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS SETTING UP THE PRESS FOR OPERATION For shipping convenience, the gauge, pump handle, hoist crank, screw nose and base angles

More information

How To Order A Direct Flow Air Cleaner

How To Order A Direct Flow Air Cleaner Reduced Volume - Improved Performance - Flexible Packaging The patented Direct Flow technology provides the flexibility to optimize the air system performance to size ratio, meeting the demands of today

More information

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010 CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010 1. Background Class II Type B Biosafety Cabinets (BSCs) are unique laboratory

More information

INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS

INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS GENERAL DESCRIPTION:

More information

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

WHI 90-Minute Rated Veneered Door Frame Installation Instructions No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,

More information

BLADDER SURGE CONTROL SYSTEM

BLADDER SURGE CONTROL SYSTEM PART I GENERAL 1.01 Description BLADDER SURGE CONTROL SYSTEM This specification describes the requirements for a Bladder Surge Control System. The purpose of the system is to minimize transient pressures

More information

How To Install An Evaporator Coil

How To Install An Evaporator Coil EVAPORATOR COIL INSTALLATION INSTRUCTIONS EVAPORATOR COIL SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... System Requirements... Location Requirements... Drain Requirements... INSTALLATION INSTRUCTIONS...

More information

Installation Instructions

Installation Instructions READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

More information

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast

More information

Wastewater Capital Projects Management Standard Construction Specification

Wastewater Capital Projects Management Standard Construction Specification CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,

More information

CLEAR-DIVISIONS APERTO

CLEAR-DIVISIONS APERTO CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the

More information

Slide the new steering column shaft through the steering column from the driver compartment.

Slide the new steering column shaft through the steering column from the driver compartment. Slide the new steering column shaft through the steering column from the driver compartment. Push the column shaft through the steering column until the machined end is out past the column lower bushing.

More information

security products metric sizes Redefine your comfort zone. www.titus-hvac.com

security products metric sizes Redefine your comfort zone. www.titus-hvac.com metric sizes secure lethal objects monitoring areas suicide deterrent Redefine your comfort zone. www.titus-hvac.com humid areas prevents corrosion minimum security medium security maximum security Table

More information

HYDRAULIC TABLE CART 500-LB.

HYDRAULIC TABLE CART 500-LB. HYDRAULIC TABLE CART 500-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic

More information

MUELLER FALLING FILM CHILLERS

MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Mueller s falling film chiller is to cool food-grade

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs. Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12

More information

OWNER S MANUAL Table Tennis Table Patent Pending

OWNER S MANUAL Table Tennis Table Patent Pending OWNER S MANUAL Table Tennis Table Patent Pending Be sure to write your model number and serial number here for future reference. You can find these numbers printed on the bottom of the table. MODEL # T8179

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for

More information

INSTALLATION AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL CI8100 IMI Wilshire, Inc. IMI WILSHIRE, INC. COUNTER INTELLIGENCE BEVERAGE SYSTEM CI8100 INSTALLATION AND SERVICE MANUAL 1993 IMI Wilshire, Inc. TABLE OF CONTENTS CI8100 IMI Wilshire, Inc. SECTION I CI8100

More information

All-Season Sunroom Sliding Glass Door Installation Instructions

All-Season Sunroom Sliding Glass Door Installation Instructions ASRESGD-08 All-Season Sunroom Sliding Glass Door Installation Instructions Panel Frame Door Frame Left Side Foam Insulator IE241 H Bar Assembly Door Frame Top Track Panel Frame Door Frame Right Side Stationary

More information

PBX Series Quick Fit Connector Bimetallic Steam Traps

PBX Series Quick Fit Connector Bimetallic Steam Traps 6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

Laminar Flow Cabinets

Laminar Flow Cabinets Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical

More information

Fisher 249 Caged Displacer Sensors

Fisher 249 Caged Displacer Sensors Instruction Manual 249 Caged Sensors Fisher 249 Caged Displacer Sensors Contents Introduction... 1 Scope of Manual... 1... 2 Type Number... 3 Educational Services... 4 Maintenance... 4 Cleaning the Cage...

More information

1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.

1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated. CAST IN PLACE DETECTABLE/TACTILE WARNING SURFACE TILE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Special Conditions and Division 1 Specifications

More information

SureSite Magnetic Liquid Level Indicator

SureSite Magnetic Liquid Level Indicator SureSite Magnetic Liquid Level Indicator Instruction Bulletin No. 177664-1 (Rev. E) Section 1: Weldments Thank you for purchasing the GEMS SureSite Magnetic Level Indicator. Please read this document prior

More information

How To Install A Perfect 16 Id Series Filter System

How To Install A Perfect 16 Id Series Filter System IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System Perfect 16 Installation Manual Product Data High-Performance Medical-Grade Residential/Commercial Air Filtration System Application The

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

LABORATORY SAFETY INSPECTION CHECKLIST

LABORATORY SAFETY INSPECTION CHECKLIST LABORATORY SAFETY INSPECTION CHECKLIST As part of EH&S's laboratory safety survey program, we have compiled a list of the most common safety problems. This is not a list of every possible hazard, but can

More information

CLEAR-DIVISIONS VARIOFOLD

CLEAR-DIVISIONS VARIOFOLD CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:

More information

Utility Distribution Systems

Utility Distribution Systems Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date

More information

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source. Mueller Pipe Repair Products Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source. SERVICE SADDLES Mueller service saddles, available in bronze,

More information

STEEL-RITE II or III COMMERCIAL SECTIONAL DOOR Owner s Manual Supplement Model 52242 NOTICE TO USER

STEEL-RITE II or III COMMERCIAL SECTIONAL DOOR Owner s Manual Supplement Model 52242 NOTICE TO USER STEEL-RITE II or III COMMERCIAL SECTIONAL DOOR Owner s Manual Supplement Model 52242 NOTICE TO USER Thank you for purchasing the Steel-Rite II or III, model 52242 commercial sectional door from RITE-HITE

More information

Premier & Deluxe 3-Season Room Sliding Glass Door

Premier & Deluxe 3-Season Room Sliding Glass Door DTSSGD-11 Premier & Deluxe 3-Season Room Sliding Glass Door Installation Instructions Screen Door Seal Left Side Track Top Track Assembly Right Side Track Right Side Trim Sliding Glass Door Sliding Screen

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Baumann 87000 Flexsleev Sanitary Control Valve

Baumann 87000 Flexsleev Sanitary Control Valve Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found

More information

ROOF TOP MOUNTED Air Handler Specification

ROOF TOP MOUNTED Air Handler Specification ROOF TOP MOUNTED Air Handler Specification PART 1: GENERAL (Model RT) Mechanical Specification 1.01 WORK INCLUDED A. Provide complete air handling unit(s) suitable for outdoor installation. Contractor

More information

Laminar Flow Cabinets and Workstations

Laminar Flow Cabinets and Workstations VERTICAL AND HORIZONTAL HEPA FILTERED SYSTEMS FOR PROCESS OR OPERATOR PROTECTION Laminar Flow Cabinets and Workstations For procedures requiring protection from particulate contamination and for aseptic

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work Revised 02-00 TECHNICAL BULLETIN Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves This technical bulletin covers both cab and chassis leveling valves manufactured by Meritor WABCO. While the

More information

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating

More information

INSTRUCTION BOOK FOR. Lace And Grommet Theater-Type Screens

INSTRUCTION BOOK FOR. Lace And Grommet Theater-Type Screens INSTRUCTION BOOK FOR Lace And Grommet Theater-Type Screens Pre-Installation Da-Lite Lace and Grommet screens are custom made to meet the requirements for large surface installation of a relatively permanent

More information

Series 18 Pass Thru Air Lock Cleanroom Entry System

Series 18 Pass Thru Air Lock Cleanroom Entry System OPERATION & MAINTENANCE INSTRUCTIONS FOR Series 18 Pass Thru Air Lock Cleanroom Entry System SOLUTIONS BUILT TO YOUR SPECIFICATIONS 8605 Wyoming Ave. N. Minneapolis MN 55445 fax: 763.425.2004 e-mail: [email protected]

More information

FIRE DAMPER APPLICATION GUIDE

FIRE DAMPER APPLICATION GUIDE FIRE AND CEILING RADIATION DAMPERS FIRE DAMPER APPLICATION GUIDE Use this application guide to help determine what type of fire damper best suits the application. Below are listed the ten Metal-Fab fire

More information

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL Please read these instructions carefully and completely before attempting to install Hale Pet Doors; they will guide you through the steps

More information

ORIFICE PLATES. CONCENTRIC BORE: For standard fluid conditions an Orifice Plate would have a centrally located orifice bore.

ORIFICE PLATES. CONCENTRIC BORE: For standard fluid conditions an Orifice Plate would have a centrally located orifice bore. SUPERIOR PRODUCTS, INC. 20550 MADISON STREET, TORRANCE, CA 90503 ORIFICE PLATES MANUFACTURING STANDARDS: Superior Products manufactures Orifice Plates in strict accordance with the specifications of: AGA.,

More information

CUNO TM Series NB Bags for Liquid Filtration

CUNO TM Series NB Bags for Liquid Filtration CUNO TM Series NB Bags for Liquid Filtration Customers have relied on CUNO to provide quality filtration solutions for the most demanding applications. Leveraging 3M innovation, CUNO has applied this expertise

More information

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:

More information

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression

More information

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace Our thanks to OK International for allowing us to reprint the following. Why do we need fume extraction? Today s Electronics workplace

More information

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS A. SCOPE 1. This information is intended to assist contractors, installers and code officials in the proper design and installation of flexible

More information

Roof Curbs, Extensions and Equipment Supports

Roof Curbs, Extensions and Equipment Supports Roof s, Extensions and Equipment Supports December 2012 Roof Page s, Header Extensions and Equipment Supports Table of Contents Model GPI Standard and Optional Construction Features... 3 Model Number Code....

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware. 14 gauge stainless steel The Original, Long Life Sanitary Guide Rail Valu Guide rail incorporates two outstanding materials: stainless steel and UHMW. The 14 ga. stainless steel sheath provides rigid streamlined

More information