GWY-500 (Profibus Gateway) USER S MANUAL
|
|
|
- Merry Russell
- 9 years ago
- Views:
Transcription
1 GWY-500 (Profibus Gateway) USER S MANUAL
2 COPYRIGHT NOTICE This manual is a publication of Renu Electronics Pvt. Ltd. and is provided for use by its customers only. The contents of the manual are copyrighted by Renu Electronics Pvt. Ltd.; reproduction in whole or in part, for use other than in support of Renu Electronics Pvt. Ltd. equipment, is prohibited without the specific written permission of Renu Electronics Pvt. Ltd.. SERVICE If service is required then pack the unit in its original packaging container or, if unavailable, any suitable rigid container. If a substitute container is used, surround the unit with shock absorbing material; damage in shipment is not covered by the warranty. Include a letter with the unit describing the difficulty and Hardware Revision and Software Version. Send to the following address: Renu Electronics Pvt. Ltd. Survey No. 2/6, Baner Road, Pune India All returns will be tested to verify customer claims of noncompliance with the product warranty. Improper return packaging, which makes verification impossible, will void the warranty. If noncompliance is verified and is not due to customer abuse or the other exceptions described with product warranty,renu Electronics Pvt. Ltd. will, at its option, repair or replace the Product returned to it, freight prepaid, which fail to comply with the foregoing warranty, provided Renu Electronics Pvt. Ltd. is notified of such noncompliance within the one-year warranty period. ASSISTANCE This manual is designed to provide the necessary information for trouble-free installation and operation of your new Gateway product. However, if you need assistance, please call Renu Electronics Pvt. Ltd. at or visit our web site at MANUAL REVISION If you contact us in refference to this manual, please include the following document number Name : Profibus Gateway (GWY-500-B) User s Manual Part Number : URML204 Document : UMAN\GWY-500-B\0106 Revision : Revision 5 Revision Number Date Description Preliminary 10/11/2005 First Release Revision 0 19/01/2006 GSD file location is specified. Revision 1 17/03/2006 GSD file location is specified. GSD file model name is changed. Communication and IBM cable details are added. Revision 2 14/02/2007 GWY-500 features (Default Communication Register, Recipes, Control word for IDB,diagnostic Information) added. Cable details for thomson controller, optomux, ABDF1, Hostlink & yokogawa are added. Revision 3 08/10/2007 Setup of Profibus Option Card with Siemens Profibus Master is revised. (Section 8.2) Revision 4 02/08/2010 NS to GWY-500 cable connections are revised. Revision 5 12/12/2011 System requirement for gateway setup software revised
3 Warranty Certificate For New product: This product is warranted against defects in materials and workmanship for a period of 12 months from the date of shipment to Buyer. For Rectified Products: Any product that will be replaced will have Warranty for 6 months or upto Original Product Warranty period whichever is greater. The warranty is limited to repair or replacement of the defective unit at the option of the manufacturer. This warranty is void if the product has been altered, misused, dismantled, or otherwise abused. ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, ARE EXCLUDED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. MAINTENANCE & SERVICE : There are no parts that can be serviced by the user. Service should be performed on a unit substitution basis only. Do not attempt to remove, replace or service any printed circuit board, components or any hardware/software related with display product. If problem within the display product occurs, contact the factory for service information or repair. NOTE : Renu Electronics Pvt. Ltd. is dedicated to providing complete customer service and customer satisfaction. If you have any comments or criticisms about how to improve the product features/reliability, Please make a note of the problem/improvement and notify us. We are always open to new ideas and improvements. So please let us know your ideas and comments. IMPORTANT Gateway Products are intended to be Protocol Converters/Data Sharer devices that can also take control actions on request of device being connected. It is assumed that user is well acquainted with the PLC / Inverters / Controllers being used. Any Mechanical or Electrical Modification to this Unit will void all Warranties.
4 Contents INTRODUCTION Purpose of this manual Introduction to Gateway GWY-500 Specifications 9 HARDWARE Dimensional details And Mounting Instructions Communication Port Details LED Status 15 GETTING STARTED Introduction To Profibus Protocol Architecture Device Types PROFIBUS-DP Characteristics Bus Access Protocol Data Throughput Diagnostic Functions Protection Mechanism Network States Device Data Base Files Profiles Introduction To GWY GWY-500 Configuration Configuration of GWY-500 (IBM Download) When GWY-500 can accept configuration? 25 GWY-500-B FEATURES Gateway Modes Master-Master Configuration Master-Slave Configuration Repeat Cycle Control Word Error Indication Bit Communication Parameters Default Communication Register Recipes Control word for IDB Diagnostic Profibus Connection Status word 38 NOTE ON COMMUNICATION DRIVERS Note On Communication Drivers 40 TYPICAL PROJECTS Project Setup Connect Toshiba Inverter as Profibus DPV0 Slave on Profibus Network with GWY Connect Modicon PLC or other Modbus Slave devices as Profibus DPV0 Slave on Profibus Network with GWY-500-B Connect SCADA Software on Profibus Network 50 CONFIGURATION SOFTWARE System Requirements Installation Instruction 53
5 PROFIBUS MASTER SETUP Setup Of GWY-500 with Omron Profibus Master Setup Of GWY-500 with Siemens Profibus Master 69 APPLICATIONS Possible Applications of GWY-500-B 82 CABLE DIAGRAMS Communication Cables TOSHIBA VF-S11 TO GWY TOSHIBA T1 LINK PORT TO GWY OMRON MASTER PROFIBUS PORT TO GWY-500 PROFIBUS PORT SIEMENS MASTER PROFIBUS PORT TO GWY-500 PROFIBUS PORT NS TO GWY THOMSON TECHNOLOGY CONTROLLER TO GWY OPTOMUX TO GWY YOKOGAWA CONTROLLER TO GWY AB SLC DH485 PORT TO GWY-500 (EC-P ) A B SLC DF1 PORT TO GWY-500 (EC-P-027B-00) AB MICROLOGIX SERIES PLCs TO GWY-500 (EC-P-027A-00) OMRON CQM1 PLC TO GWY-500 (EC-P-006B-00) OMRON CQM/CPM CMOS PORT TO GWY-500 (EC-P-006A-00) IBM Cables IBM CABLE FOR GWY
6 Introduction In this chapter.... INTRODUCTION Purpose of this manual Introduction To Gateway GWY-500-B Specifications 6
7 Introduction 1.1 Purpose of this manual Thank you for purchasing GWY-500 Product from Renu Electronics Pvt. Ltd.. The intention of this User Manual is to provide a guide for Safe installation, Configuration and operation of GWY-500 Functionality of all the Gateway models is same. Read this User manual thoroughly before installing and operating GWY-500, This document is based on information available at the time of its publication. While efforts have been made to be accurate, the information in this document may not cover all the details or variations in hardware or software. Features described herein may not be present in all hardwares. Renu Electronics Pvt. Ltd. reserves the right to update information in this publication without prior notice. 1.2 Introduction to Gateway Gateway is a Protocol Converter / Data sharer for devices like PLCs, inverters (Adjustable Speed Drives), and other Controllers. Gateway has two serial ports that connect with two different devices. These devices share data through Gateway. Gateway communicates with a device to get the information required by the device connected on the other port. The device that requires data is called Destination Device and the device that provides data is called Source Device. Information could be, - value of a PLC register. - status of a PLC coil. - Command from Source Device to Destination Device to perform any action at the destination end. Configuration Of Gateway COM1 / PLC 1 (RS232/RS485/CMOS) C US LR Pending PLC1 OK Profibus GWY-500-B } DC+ DC- EARTH 24V DC +/- 10% Renu Electronics Pvt. Ltd. Survey No. 2/6, Baner Road, Pune INDIA Profibus - DP (Slave) Note: Please refer IBM Download in section
8 Introduction Normal Operation: Node 1 ~ Drive Motor PLC Profibus-DP Protocol GWY-500-B X Protocol PLC1 PLC PLC (Profibus Master) Node n Node 2 PID Controller Connect Profibus Master device to Gateway via Profibus port and serial device (PLC or Inverter) via the PLC s communications port (correct cables are required) and the PLCs can easily exchange information with the Profibus-DP devices. 8
9 Introduction 1.3 GWY-500 Specifications Power : 24 V DC, 2.5 W LED s : 3 LED s for status indication Communication Ports : 2 Communication ports with COM1 : RS232 / RS422 / RS485 / CMOS COM2 : Profibus-DPV0 Slave (2 Wire RS485) (Isolation between communication ports and Power supply, through DC-DC coupler is 1 KV) COM1 / PLC1 : Connects to PC for setup download or connects to PLC1 at runtime. COM2 / PLC2 : Profibus-DPV0 Slave (2 Wire RS485) (Isolation between communication ports, through opto-isolation is 1KV rms for 1 min) Profibus Baud Rate : 9.6k, 19.2k, 45.45k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M Bit/s (Autodetect) GSD File : Supplied in the Installable Software CD. GSD File Name : RENU0A0E.GSD I/O data : 100 Word Input, 100 Word Output *Profibus Slave ID : (ID should be provided through Gateway Setup Software/PLC2 Settings/Advanced) Operating Temperature : 0 o to 60 o C Storage Temperature : -20 o to 80 o C Humidity : 10% to 90% (Non condensing) Mounting : DIN rail or back panel mounting Dimensions (DIN rail) : 105mm(L) X 40mm(D) X 51mm(W) Weight : 125 gm approx. Certifications : CE with UL certification Immunity to ESD : Level 3 as per IEC Immunity to Transients : Level 3 as per IEC Immunity to Radiated RF : Level 3 as per IEC Immunity to Conducted RF : Level 3 as per IEC Emissions : EN55011 CISPR A Note1 : If Toshiba VF-S11 Inverter is connected at COM1 of GWY-500, station number is detected automatically at power ON and that station number is assigned as a Profibus Slave ID. Inverter ID Can be set from Note2 : Once You install Gateway Setup Software, you will find GSD file at: C:\Program Files\Gateway 3.XX\GWY-5oo(Profibus Gateway)\GSD. This is the default path. The actual path is where the user has installed Gateway Setup Software. Note3 : GSD file is also provided in the CD along with the Installable software. Note4 : Previously the model name in GSD file was GWY-500 Now it is changed to GWY-XXXXX to support all the products having Profibus port. Note5 : Profibus detects baud rate automatically. So baud rate field in PLC2 Settings of Gateway software does not have meaning specific meaning. Source ID and Destination ID related to Profibus driver does not have specific meaning. Profibus ID is set by Gateway configuration software. (PLC2 settings/advanced). 9
10 Hardware HARDWARE In this chapter.... Dimensional Details And Mounting Instructions Communication Port Details LED Status 10
11 Hardware 2.1 Dimensional details And Mounting Instructions GWY-500 -B unit can be mounted on a back panel or on a DIN rail or can be left hanging. It comes with a separate DIN rail plate when it is packed. User will have to attach the DIN rail plate to the unit if it has to be mounted on a panel or DIN rail. If it has to be left hanging, make sure to screw the cables to the DB9 connectors on the Gateway unit. DIN rail plate also has the provision to screw the unit to the back panel. Following drawing shows how to attach the DIN rail plate to the unit: 40 DIN rail clamp Slot for clamp GWY-500 DIN rail clip Follow instructions given below: 1. Attach the DIN rail plate to the unit using the clamps on the DIN rail plate. 2. Pull out the clip of the plate. 3. Put the unit on the DIN rail. 4. Push the clip in to secure the unit on the DIN rail. GWY-500 unit is shipped with a separate DIN rail plate which has to be attached to the unit, if needed. User can use the unit with or without the DIN rail plate. Following sketch shows mounting details of GWY-500 with the DIN rail plate. 11
12 Hardware 2.2 Communication Port Details GWY-500 has two communication ports COM1 and COM2. COM1 port is compactible to RS232/ RS422/ RS485 and CMOS signal levels. Pinout of this port is given as follows: PLC1 / COM1 RX- (RS422/RS485) TX- (RS422/RS485) TXD (CMOS) +5VDC* (DO NOT USE) Signal Ground RX+ (RS422/RS485) RXD (RS232C/CMOS) TXD (RS232C) TX+ (RS422/RS485) DB9 Female *Do not use pin no. 6 of PLC1 / COM1. **Refer our website ( for your specific Cable requirements 12
13 Hardware Pin Description Pin Name Signal Level Description 1. TX+ RS422 / RS485 Differential Transmit +, also referred as TXA 2. TXD RS232 Transmit 3. RXD RS232 / CMOS Receive 4. RX+ RS422 / RS485 Differential Receive +, also referred as RXA 5. GND - Signal Ground common to all signals VDC - DO NOT USE 7. TXD CMOS Transmit 8. TX- RS422 / RS485 Differential Transmit -, also referred as TXB 9. RX- RS422 / RS485 Differential Receive -, also referred as RXB User can convert RS485 4 wire + Signal Ground system to a 2 Wire + Signal Ground system by shorting following signals in the communication cable: TX+ TX- A RX+ B RX- SG SG Note: If user has attached shield to Earth on Device end, leave the shield open on Gateway end. If user has connected shield to Signal Ground on Device end, connect shield to Signal Ground on Gateway end. A and B are polarity insensitive. Twisted pair cable should be used for RS485 Network. Upto 31 Devices can be multi-dropped on RS485 port of Gateway. 13
14 Hardware Profibus - DP Slave A (+) Data Line +5V DC (Supply Voltage for terminator resistance) Data Ground RTS(TTL Direction control for repeaters) B (-) Data Line Shield / Functional Ground DB9 Female Data Line: The Profibus user group recommends the following color coding for the data signal lines: A-Data Line = Green B-Data Line = Red These data signal lines must be connected to the corresponding signal terminals or pins at the master unit and other stations (i.e. A to A, B to B). RTS: The signal RTS (TTL signal relative to Data Ground) is meant for the direction control of repeaters in case repeaters without self control capability are used. +5V DC, Data Ground: The signals +5V DC and Data Ground are meant to power an externally mounted bus terminator. The powering of the 220 termination resistor ensures a defined idle state potential on the data lines. To ensure proper functioning up to the highest baud rate, each bus segment has to be terminated at both ends of the cable. +5V DC 300 Ohm B - Data Line 220 Ohm A - Data Line 300 Ohm Data Ground 14
15 Hardware 2.3 LED Status There are 3 Bicolor LEDs for status indication. Bicolor LEDs status: LED OK Green OFF No Firmware Flashing ON IBM Download Both side (COM1 and COM2) communication OK Red OFF Configuration Ok ON Configuration Fault PLC1 Green OFF No data received on PLC1 Port Flashing Receiving data on PLC1 Port ON - Red OFF No error in PLC1 attach or while block execution Flashing PLC1 attach error or error while block execution ON - Profibus Green OFF No data received on Profibus Port Flashing Receiving data on Profibus Port ON - Red OFF Data exchange with Profibus Master Flashing - ON No data exchange with Profibus Master 15
16 Hardware Note: At power on, OK LED is steady ON for approximately 5 seconds. Here it sends requests to device connected on serial port. If a device connected on serial port is not detected, OK LED blinks for 10 seconds and again steady for approximately 5 seconds as Profibus Gateway (Gateway 500) sends requests to serial ports device. This process is continued until a device connected on serial port is detected. If that device is detected, Profibus port is initialised. After successful Profibus initialisation, gateway 500 starts exectuting the project blocks. At this point, Ok LED is steady ON. serial port and Profibus LED are blinking. Now, if the gateway 500 detects that Profibus master is not present then it stops the block execution and continuously waits for Profibus Master. At this time OK LED is steady on and serial port and Profibus LEDs are off. 16
17 Getting Started In this chapter.... GETTING STARTED Introduction To Profibus Introduction To GWY-500-B GWY-500-B Operation 17
18 Getting Started 3.1 Introduction To Profibus PROFIBUS is a vendor-independent, open fieldbus standard for a wide range of applications in manufacturing, process and building automation. Vendor independence and openness are guaranteed by the PROFIBUS standard EN With PROFIBUS, devices of different manufacturers can communicate without special interface adjustments.the PROFIBUS family consists of three compatible versions: High speed Process Automation Higher level Uniform bus access protocol PROFIBUS-DP DP stands for Decentralised Periphery. It is optimised for high speed and low cost interfacing, especially designed for communication between automation control systems and distributed I/O at the device level. PROFIBUS-PA PA stands for Process Automation. It permits sensors and actuators to be connected on one common bus line even in intrinsically-safe areas. It permits data communication and power supply over the bus using 2-wire technology according the international standard IEC PROFIBUS-FMS FMS stands for Fieldbus Message Specification. This version is the general purpose solution for communication tasks at a higher level. Powerful services open up a wide range of applications and provide great flexibility. It can also be used for extensive and complex communications tasks. PROFIBUS-DP and PROFIBUS-FMS use the same transmission technology and a uniform bus access protocol. Thus, both versions can be operated simultaneously on the same cable. However, FMS field devices cannot be controlled by DP masters or vice versa. Note: It is not possible to exchange one of these family members by another family member. This will cause faulty operation Protocol Architecture The rest of this section only describes PROFIBUS-DP.Protocol architecture. OSI The PROFIBUS protocol architecture is oriented on the OSI (Open System Interconnection) reference model in accordance with the international standard ISO Layer 1 (physical layer) of this model defines the physical transmission characteristics. Layer 2 (data link layer) defines the bus access protocol. Layer 7 (application layer) defines the application functions. DP- Profiles DP- Extentions User Interface Layer (7) Application Layer (6) Presentation Layer (5) Session Layer (4) Transport Layer (3) Network Layer (2) Data Link Layer (1) Physical Layer DP- Basic Functions Not Defined Field Bus Data Link (FDL) RS-485 / Fiber optics 18
19 Getting Started Layer 1, 2 and user interface Transmission medium High-speed, inexpensive Easy installation Cable length PROFIBUS-DP uses layers 1 and 2, and the user interface. Layers 3 to 7 are not defined. This streamlined architecture ensures fast and efficient data transmission. The application functions which are available to the user, as well as the system and device behaviour of the various PROFIBUS-DP device types, are specified in the user interface. RS-485 transmission technology or fibre optics are available for transmission. RS-485 transmission is the most frequently used transmission technology. Its application area includes all areas in which high transmission speed and simple inexpensive installation are required. Twisted pair shielded copper cable with one conductor pair is used. The RS-485 transmission technology is very easy to handle. Installation of the twisted pair cable does not require expert knowledge. The bus structure permits addition and removal of stations or step-by-step commissioning of the system without influencing the other stations. Later expansions have no effect on stations which are already in opera tion. Transmission speeds between 9.6 kbit/s and 12 Mbit/s can be selected. One unique transmission speed is selected for all devices on the bus when the system is commissioned. The maximum cable length depends on the transmission speed The specified cable lengths are based on type-a cable. The length can be increased by the use of repeaters. The use of more than 3 repeaters in series is not recommended Device Types PROFIBUS distinguishes between master devices and slave devices. Master devices DPM1, DPM2 Slave devices Master devices determine the data communication on the bus. A master can send messages without an external request, as long as it holds the bus access right (the token). Masters are also called active stations in the PROFIBUS standard. There are two types of master devices: DP master class1 (DPM1) and DP master class2 (DPM2). A DPM1 is a central controller which exchanges information with the decentralised stations (i.e. DP slaves) within a specified message cycle. DPM2 devices are programmers, configuration devices or operator panels. They are used during com missioning, for configuration of the DP system, or for operation and monitoring purposes. Slave devices are peripheral devices. Typical slave devices include input/output devices, valves, drives, and measuring transmitters. They do not have bus access rights and they can only acknowledge received messages or send messages to the master when requested to do so. Slaves are also called passive stations. 19
20 Getting Started PROFIBUS-DP Characteristics Bus Access Protocol Layer 2 Medium Access Control Token passing Polling procedure The bus access protocol is implemented by layer 2. This protocol also includes data security and the handling of the transmission protocols and messages. The Medium Access Control (MAC) specifies the procedures which determine when a station is permitted to transmit data. A token passing procedure is used to handle the bus access between master devices, and a polling procedure is used to handle the communication between a master device and its assigned slave device(s). The token passing procedure guarantees that the bus access right (the token) is assigned to each master within a precisely defined time frame. The token message, a special message for passing access rights from one master to the next master, must be passed around the logical token ring - once to each master - within a specified target rotation time. Each master executes this procedure automatically. A user can only change the target rotation time, but is not recommended. The polling or master-slave procedure permits the master, which currently owns the token, to access its assigned slaves. The picture below shows a possible configuration The configuration shows three active stations (masters) and six passive stations (slaves). The three masters form a logical token ring. When an active station receives the token message, it can perform its master role for a certain period of time. During this time it can communicate with all assigned slave stations in a master- slave communication relationship, and a DPM2 master can take the initiative to communicate with DPM1 master stations in a master-master communication relationship. Multi-peer communication In addition to logical peer-to-peer data transmission, PROFIBUS-DP provides multi-peer communication (broadcast and multicast). Broadcast communication: An active station sends an unacknowledged message to all other stations (masters and slaves). Multicast communication: An active station sends an unacknowledged message to a predetermined group of stations (masters and slaves). 20
21 Getting Started Data Throughput Transmission time At 12 Mbit/s, PROFIBUS-DP requires only about 1 ms for the transmission of 512 bits of input data and 512 bits of output data distributed over 32 stations. The figure below shows the typical PROFIBUS-DP transmission time depending on the number of stations and the transmission speed. The data throughput will decrease when more than one master is used Diagnostic Functions Extensive diagnostics Device related diagnostics Module related diagnostics Channel related The extensive diagnostic functions of PROFIBUS-DP enable fast location of faults The diagnostic messages are transmitted over the bus and collected at the master. These messages are divided into three levels: 1. Device related diagnostics These messages concern the general operational status of the whole device (e.g. overtemperature or low voltage). 2. Module related diagnostics These messages indicate that a fault is present in a specific I/O range (e.g. an 8-bit output module) of a station. 3. Channel related diagnostics These messages indicate an error at an individual input or output (e.g. short circuit on output 5) Protection Mechanism Time monitoring At the master PROFIBUS-DP provides effective protection functions against parameterisation errors or failure of the transmission equipment. Time monitoring is provided at the DP master and at the DP slaves. The monitoring interval is specified during the configuration. 1. Protection mechanism at the master. The DPM1 master monitors data transmission of its active slaves with the Data_Control_Timer. A separate control timer is used for each slave. This timer expires when correct data transmission does not occur within the monitoring interval. If the master s Auto_Clear mode is enabled, the DPM1 exits the Operate state, switches the outputs of all assigned slaves to fail-safe status, and changes to its Clear state. 21
22 Getting Started At the slave 1. Protection mechanisms at the slave. The slave uses the watchdog control to detect failures of the master or the transmission line. If no data communication with the master occurs within the watchdog control interval, the slave automatically switches its outputs to the fail-safe status. This mechanism can be enabled or disabled for each individual slave. Also, access protection is available for the inputs and outputs of the DP slaves operat ing in multi-master systems. This ensures that direct access can only be performed by the authorised master. For other masters, the slaves offer an image of their inputs and outputs, which can be read by any master, even without access rights Network States PROFIBUS-DP distinguishes four different network states. Off-line Stop Clear Operate Auto_Clear 1. Off-line Communication between all DP participants is stopped. 2. Stop Communication between DPM1 and DP slaves is stopped. Only communication between DPM1 and DPM2 is possible. 3. Clear DPM1 master attempts to set parameters, check the configuration, and subsequently perform data exchange with its associated DP-slaves. The data exchange comprises reading the inputs of the DP-slaves and writing zero s to the outputs of the DP-slaves. 4. Operate DPM1 master exchanges data with its assigned slaves, inputs are read and outputs are written. Beside this, the DPM1 cyclically sends its local status to all assigned DP slaves (with a multicast message) at a configurable time interval. When an error occurs during the data transfer phase of the DPM1, the Auto_Clear configuration setting determines the subsequent actions. If this parameter is set to false, the DPM1 remains in the Operate state. If set to true, the DPM1 switches the outputs of all assigned DP slaves to the fail-safe state and the network state changes to the Clear state Device Data Base Files GSD-file To achieve straightforward configuration of a PROFIBUS-DP network, the characteristic features of a device are specified in a file. This file is called a GSD-file (Gerätestammdaten file). The language of the GSD file is expressed with the last letter from the extension, *.GS?: Default : = GSD English : = GSE Deutsch : = GSG Italian : = GSI Portugees : = GSP Spanish : = GSS The GSD files are prepared individually by the vendor for each type of device, according to a fixed format. Some parameters are mandatory, some have a default value and some are optional. The device data base file is divided into three parts: 22
23 Getting Started General section DP-master section DP-slave section Configurator 1. General specifications This section contains the vendor name, the device name, hardware- and software release versions, station type and identification number, protocol specification and supported baud rates. 2. DP master-related specifications This section contains all parameters which only apply to DP master devices (e.g. maximum memory size for the master parameter set, maximum number of entries in the list of active stations, or the maximum number of slaves the master can handle). 3. DP slave-related specifications This section contains all specification related to slaves (e.g. minimum time between two slave poll cycles, specification of the inputs and outputs, and consistency of the I/O data). The device data base file of each device is loaded in the configurator and downloaded to the master device. Refer to the Operation Manual of the PROFIBUS-DP Master Unit for usage of the GSD file in the master s configuration software. GSD files are usually supplied with each unit. Alternatively, GSD files can be downloaded from the Internet, either from the manufacturer s site, or from the GSD library of the PROFIBUS Nutzerorganisation at Profiles Exchanging devices To enable the exchange of devices from different vendors, the user data has to have the same format. The PROFIBUS-DP protocol does not define the format of user data, it is only responsible for the transmission of this data. The format of user data may be defined in so called profiles. Profiles can reduce engineering costs since the meaning of application-related parameters is specified precisely. Profiles have been defined for specific areas like drive technology, encoders, and for sensors / actuators. 3.2 Introduction To GWY-500 GWY-500 is a communication bridge between Profibus Network interface on one side and various serial protocols on the other side. GWY-500 allows serial devices to act as Profibus Slave on Profibus Network. COM1 Any Serial Driver 3K Internal Database Memory Gateway (Firmware System) COM2 (Profibus slave driver) 100 words Input 100 words Output 23
24 Getting Started On COM1 side it supports serial protocols (e.g. Modbus Mastre, Modbus Slave) and on COM2 side it has Profibus DPV0 Slave Protocol. Profibus Slave uses internal memory. It is divided into two parts, Input Area and Outptut Area. Profibus master writes data in Output Area and reads the data from Input Area. With Gateway project it is possible for serial devices to read the data from Output Area and write the data in Input Area of Profibus Slave. GWY-500 is externally powered from 3 pin terminal block and power is isolated from both communication ports. Both the communication ports are also isolated from each-other. It has two communication ports, one with Profibus-DPV0 network interface (9.6Kbps to 12 Mbps) and serial port with RS232 / RS422 / 2 or 4 wire RS485 (300 to 115.2K). Microsoft Windows based configuration software, Gateway Setup, helps user to configure Gateway unit. Configuration means making the Gateway unit work as per the system requirements. The complete configuration for a unit is termed as Project. Project comprises of device names, Register addresses, condition for block execution etc. Block may contain information like copy number of words from one device to other device and conditions for copy, if any. Gateway transfers data between two devices by execution of blocks. After the Project is defined, Drivers for required devices and Project should be downloaded. Gateway can now communicate with the Profibus-DP Slave devices and serial devices (e.g. PLC or SCADA). 3.3 GWY-500 Configuration GWY-500 can communicate with serial and Profibus devices using appropriate cables and configuration. Microsoft Windows based configuration software, Gateway Setup, configures the GWY-500 unit. Configuration means making the GWY-500 unit work with the application. Complete configuration for a GWY-500 using the Gateway Setup is termed as a Project. A Project consists of Devices to be attached on two ports, Communication settings for two ports to communicate with two devices, Register addresses for data transfer, Conditions for data transfer etc. GWY-500 can now communicate with the specified devices without any change in the GWY-500 hardware. To communicate with a device, GWY-500 needs Communication Drivers for the devices and Gateway - Device communication cables. Each Device has a unique and predefined protocol for communication. GWY-500 driver has this protocol to communicate with the desired device. As two devices are connected on GWY-500, it requires two drivers for communication 3.4 Configuration of GWY-500 (IBM Download) User MUST download Project, PLC1 driver and PLC2 driver in Gateway before installing any system using Gateway. Gateway can accept drivers and configuration data on either of the ports. User needs a special IBM download cable for downloading configuration in Gateway. All configurations can be downloaded only form Serial port (Port 1). The other port is dedicated for Profibus Slave (Port 2). If any change in the current / working project is made, user must download the changed project in Gateway. Pin details of IBM download cable for GWY-500-B are as follows: DB9 Male (Gateway) DB9 Female (IBM)
25 Getting Started 1. For downloading Firmware,drivers and project switch off the GWY-500 unit. 2. Power ON the unit again.ok LED starts blinking. This means that unit is in download mode. 3. For the first time download all firmware, drivers and project. IMPORTANT NOTE: AS GATEWAY HAS MULTIPLE SIGNALS ON ITS COMMUNICATION PORTS, IBM CABLE FOR GATEWAY MUST HAVE ONLY THREE RS232 SIGNALS (TXD, RXD AND GND) AS MENTIONED ABOVE. NOTE: 9-9 PIN CORE CABLE SHOULD NOT BE USED. If you are using usb to serial converter then please connect IBM cable to serial port of converter When GWY-500 can accept configuration? If current driver present for PLC1 port is Master (e.g. Modbus (Gateway as Master)) First, it is checked that whether device is connected on port1 If device is connected, it continues normal operation If device is not connected, it checks for IBM download mode for 10sec. This sequence continues until either is satisfied. If current driver present for PLC1 port is Slave (e.g. Modbus (Gateway as Slave)) If Port1 of Gateway is Slave, all the configurations should be downloaded Only once for 10sec at power on. Note: Make sure that OK LED is blinking when you start downloading the configuration in Gateway. 25
26 GWY-500-B Features In this chapter.... GWY-500-B FEATURES Gateway Modes Repeat Cycle Control Word Error Indication Bits Communication Parameters Default Communication Register Recipes Control word for IDB Diagnostic Profibus Connection Status word 26
27 GWY-500-B Features 4.1 Gateway Modes Gateway has two modes of operation: Master-Master and Master-Slave. Before explaining these modes further Master and Slave concept should be explained. Master: Master is a Device / device driver which initiates communication. Slave: Slave is Device / Device driver which processes Master s query, takes necessary action and responds to the query, if necessary Master-Master Configuration In this mode both Gateway ports are master in nature and devices connected on these ports are slave. Gateway ports initiate communication when the proper Gateway-Device communication cable is attached. Data is transferred in blocks. This transfer can either be a continuous process or as per requirement. A control word (Section 4.3), present in device on either side, enabled from Gateway Setup Software, can control the block execution. When control word is disabled, then block transfer is a continuous process. A block of data is fetched from one device and transferred to the other device. The amount of data to be transferred (Number of words) depends on Block definition in Block Definition Area in Configuration Software. One block is executed at a time. A cycle consists of execution of blocks from #1 to #n. Execution of blocks is performed as follows, Block #1 Block #2 Block #3 Block # Block #n When Control word is enabled, it decides which block has to be executed by writing a specific data in the control word. 27
28 GWY-500-B Features Note on Gateway Profibus drivers: Gateway Profibus driver uses 200 words of internal memory (100 words for input and 100 words for output) as per profibus specification. This memory is divided into two parts, Input Area and Outptut Area. The first word of Input area is I000 and the first word of Output area is O000. Pofibus master writes data in Output Area and reads the data from Input Area. With Gateway project it is possible for serial devices to read the data from Output Area and also they can write the data in Input Area. This memory is shared memory for Profibus master devices and Gateway firmware system as shown bellow. COM1 Any Serial Driver 3K Internal Database Memory Gateway (Firmware System) COM2 (Profibus slave driver) 100 words Input 100 words Output Gateway firmware system and external profibus master both act as a master on this memory. Though Gateway Profibus driver is slave with respect to external profibus master device, Gateway firmware system assumes this driver as a master driver as it is master to 200 words internal memory. 28
29 GWY-500-B Features Let us see the example of Master-Master mode as shown in the picture below: Configure Gateway ports as: PLC1 Protocol: Modbus (Gateway as Master) PLC2 Protocol: Profibus # Words defines number of registers/coils to be read / written between two devices. Block #1: Gateway reads 16 words starting from from Modbus and write these 16 words data to internal memory of Profibus (Input area). Block #2: Gateway reads 16 words starting from O000 in internal memory of Profibus (Output area) and writes it to holding register starting from As this example has only two blocks, Gateway will execute Block #1 after executing Block #2 continuing this cycle forever. Notes: 1) Maximum 255 blocks can be configured in any mode. 29
30 GWY-500-B Features Master-Slave Configuration In this mode, one of the Gateway ports is a master and other is the slave so the devices connected on these ports are slave and master respectively. Blocks do not control data transfer in this mode. Data transfer takes place only when Master Device, connected on slave port of Gateway, sends a request to read / write data. This mode requires mapping registers for data transfer. Mapping means defining one or multiple registers in the Slave Device corresponding to one or multiple registers / coils in the Master Device. Mapping can be done using the Block definition area, so in this mode, any Block is used for mapping registers of the two devices. In Block Definition area, # Words Field indicates number of registers to be mapped linearly from the starting addresses of the Source Device to the Destination Device. Maximum number of registers that can be mapped is 255, but this does not mean that Master Device has to read / write 255 registers in one command. In one command Master can read / write registers from one Block only, so if multiple registers are to be read / written using a single command, # Words also limits the maximum number of registers to be read / written. Number of registers to be read /written in one command also depends on - protocol of BOTH the devices - Buffer capacity of Gateway. Now let us take the example of Master-Slave mode. Configure Gateway ports as: PLC1 Protocol - Modbus (Gateway as Slave) PLC2 Protocol - Profibus. 30
31 GWY-500-B Features 31
32 GWY-500-B Features Block #1 maps 100 words of Modbus starting from to Profibus starting from O000. Block #2 maps 100 words of Modbus starting from to Profibus starting from I000. In above example, request from Modbus Master is executed as follows: 1. Modbus Master connected on serial port (COM1) sends command to Gateway for setting holding register Gateway searches defined Blocks and checks whether this register is mapped to any Profibus word. In example, holding register is mapped to I000 in Block 2. Gateway accepts this command and sets I000. If Master sends a command to read / write a register / coil not defined in any Block then Gateway sends exception response to master. NOTES: 1) If multiple registers are to be read or written in one command, then all the registers have to be de fined in one Block. 2) As Gateway Setup Software is common for both the Gateway Modes, titles in the Block Definition Area, may not be appropriate when using Gateway in Master - Slave mode (e.g. Source ID, Source PLC, Destination PLC ). 3) Maximum 255 blocks can be configured in any mode. 4) In Master - slave mode, If somebody mapped read only registers at destination end to any registers at source end, it s users responsibility that these registers are not going to be written by master. 32
33 GWY-500-B Features 4.2 Repeat Cycle User can control Block execution by using the Repeat Cycle field. This number decides whether the Block will be executed in each cycle. Larger the number lower the priority of the Block. Range for Repeat Cycle setting is Repeat Cycle = 1 Highest priority Repeat Cycle =99 Lowest priority Repeat cycle is important when using Gateway in Master - Master mode. If Gateway is used in Master - Slave mode, Repeat Cycle field should be kept as 1. Repeat cycle defines the number of times a Block will be skipped while executing Blocks in a sequential manner. Block will not be executed for [Repeat Cycle - 1] cycles. So if Repeat Cycle for a Block is 1, it will be executed in each cycle whereas if Repeat Cycle is 2, then this Block will NOT be executed in alternate cycles. For example, suppose Blocks are defined with following Repeat Cycles: Block #1 Repeat Cycle = 1 Block #2 Repeat Cycle = 2 Block #3 Repeat Cycle = 3 Block #4 Repeat Cycle = 4 After power up, Cycles will be executed as follows: Cycle 1: Block #1 Block #2 Block #3 Block #4 Cycle 2: Block #1 Cycle 3: Block #1 Block #2 Cycle 4: Block #1 Block #3 Cycle 5: Block #1 Block #2 Block #4 4.3 Control Word Another way of controlling Block execution is by use of the Control Words. 16 control words i.e. 255 control bits are available by which user can control 255 blocks. O th Control bit corresponds O th bit of control word 1,.., 16 st Control bit corresponds 0 st bit of control word 2,.., 255 th Control bit corresponds 15 th bit of control word 16. By default 0 to 255 control bits are mapped to 1 to 256 blocks. User can change value of the control bit. Control Word can be enabled or disabled in Gateway Configuration. Normally Control Word is disabled for a New project. It can be enabled just by clicking on check box in the setup software. Control Word can be chosen from any of the Devices connected. If the Control Word field is enabled, for the control bit chosen in the project block, accordingly the number of words in the control field should be taken. For example, if 36 th Control bit is chosen to control the block then number of words in the Control Word field should be 3. Number of control bits / 16 = Number of control words. If Number of control bits % 16!= 0 (Non-zero so add 1 in the number of words in the control field) then Number of control words = Number of control words
34 GWY-500-B Features In the above example, number of control bits are 36. So 36 / 16 = 2 (Number of words in control field) 36%16 = 4 (i.e. Non-zero so add 1 in the number of words in the control field), so number of words in control field are 2+1 = 3. So number of words in the control field should be chosen as 3. For any block any control bit can be chosen. Control Word can only be used in Master-Master mode since no continuous data transfer takes place in Master -Slave mode (data transfer only takes place on Master's request) When the Control Word is disabled, Block execution is totally controlled by Repeat Cycle settings. When the Control Word is enabled, Block execution is controlled using discrete bits of that word. Bit 0 in control word controls execution of Block #1 Bit 1 in control word controls execution of Block #2 : Bit 15 in control word controls execution of Block #16 When a bit is high, 1, corresponding Block is executed depending on its Repeat Cycle. When a bit is low, 0, execution of corresponding Block is disabled. 4.4 Error Indication Bit This feature enables detection of communication breaks during error free communication between Gateway and two devices. Communication breaks can occur due to no cable connection, wire faults, device power failure at both ends of Gateway. An Error bit can be designated in each external device connected to Gateway. Using this bit, fault at the PLC1 end can be reported to PLC2 Device and fault at PLC2 end can be reported to PLC1 Device. When communication error occurs on PLC1, Gateway sets error bit in PLC2 device. Error Indication Bit can only be used in Master-Master mode. In Master-Slave mode any error can easily be detected by a communication time out on the Master. Error indication bit can be enabled using Gateway configuration software. Normally Error bit is disabled for a New project. It can be enabled just by clicking on the check box in the setup software. Error indication bit can be enabled in both or any one of the Devices connected to Gateway. Error Indication bit is OFF to indicate error free communication. In case of communication error on PLC2, Gateway sets error bit on PLC1 port and vice versa. Note: If error indication bit is a bit of a bit addresable word then don t use that word in project mapping. 4.5 Communication Parameters Communication Parameters of Gateway can be set from configuration Software. This enables Gateway to readily communicate with any device. Communication parameters for PLC1 and PLC2 ports can be configured independently. This feature allows changes in Baud rate, Number. of stop bits, Parity etc. at any time without downloading the driver for that particular device. After the driver for a particular device is downloaded, the communication parameters can be changed simply by selecting new communication parameters and downloading the same project. 34
35 GWY-500-B Features 4.6 Default Communication Register Purpose: Location: To provide flexible Attach Sequence. This register is used to test communication with the device to see if device is connected and to check if settings are proper. User can access these register in Settings>> Default Communication Register menu. This feature is useful when external slave device does not allow single read operation or does not respond to any particular register. For example: Some energy meters allow reading in multiple of 16 registers only. Previously for Modbus Driver only holding register was read for attach. But if a particular device does not respond to , then the initialization will fail. What does the Default Communication Register do? After power up default communication register is the first register that is fetched by the master driver from the slave device. If response for this register is received from slave then only gateway will start the Profibus initialization. Otherwise GWY-500 would continuously try to establish the communication with external Slave device by sending read request with the default communication register. NOTE: 1) This is implemented only for master drivers that support IDB. 2) First register present in first row of IDB is taken as default communication register. 3) The no of words field for default communication register are 1, user can change the value to maximum of 255 whichever is applicable. 35
36 GWY-500-B Features 4.7 Recipes Purpose: Location: To provide user-definable write of configuration properties or control sequences at power on to the external Slave Devices. User can access these Recipes in Settings>>Recipes menu. In case of some Slaves it is necessary to write configuration properties or control sequences at power on. Drives/ Inverters generally require this kind of sequence. After power on, before Gateway Project Block execution starts, Recipes blocks will be executed and the specified value will be written into the specified registers. NOTE: 1) Recipes are only useful for master drivers. 2) All the fields in Recepies i.e. COM Port, Station ID, #Words, Register Address, Value can be changed by user. 36
37 GWY-500-B Features 4.8 Control word for IDB Purpose: To provide user s control over the IDB block execution during run time. 16 internal memory registers are added in each master driver (IM0000 to IM0015. Bits of these registers will control 255 IDB block executions. If bit value is 1 then IDB block will execute and if it is 0 then IDB block will not execute. Initially at power on all internal memory register will have value 0xFFFF, so all IDB block will execute. After communication is totally established user can change internal memory data to execute required IDB block. Why/ when is the Control Word for IDB required? S1 M1 S2 M2 Let us assume the User has defined different Blocks in the Project in Master-Slave Mode that gives rise to 20 blocks in IDB of M1 (as this is a Master Driver). Now if the external Master (M2) requires execution of only few of those 20 IDB blocks, then using the Control Word for IDB user can select only the blocks that need to be executed currently. The visible advantage is this will speed up the Block execution and data exchange rate. This feature is useful in Master-Slave mode. 37
38 GWY-500-B Features 4.9 Diagnostic Note : Input Word and Output Word is not applicable in this case This indicates serial status on Profibus side. At power on even the serial communication is not started, the profibus communication is started. The state of GWY-500 is showed in configured Profibus Diagnostic Input Word. State Description 1 Scanning nodes on serial side 2 IBM Download mode 3 Reserved 4 Data Exchange 4.10 Profibus Connection Status word This indicates Profibus status on serial side. One internal memory register is added in Profibus Driver(IM0000). Its read-only word. User can map this register while configuring the project. Data in IM0000 Description 0001 External Profibus Master is communicating with GWY No Communication 38
39 Note on Communication Drivers NOTE ON COMMUNICATION DRIVERS 39
40 Note on Communication Drivers 5.1 Note On Communication Drivers How Gateway Profibus Slave driver works? Gateway Profibus driver uses 200 words of internal memory (100 words for input and 100 words for output) as per profibus specification. This memory is divided into two parts, Input Area and Outptut Area. The first word of Input area is I000 and the first word of Output area is O000. Pofibus master writes data in Output Area and reads the data from Input Area. With Gateway project it is possible for serial devices to read the data from Output Area and also they can write the data in Input Area. I000 is Input to Profibus Master. O000 is Output from Profibus Master. This memory is shared memory for Profibus master devices and Gateway firmware system as shown bellow. COM1 Any Serial Driver 3K Internal Database Memory Gateway (Firmware System) COM2 (Profibus slave driver) 100 words Input 100 words Output Gateway firmware system and external profibus master both act as a master on this memory. Though Gateway Profibus driver is slave with respect to external profibus master device, Gateway firmware system assumes this driver as a master driver as it is master to 200 words internal memory. Note: Profibus detects baud rate automatically. So baud rate field in PLC2 Settings of Gateway software does not have meaning specific meaning. Source ID and Destination ID related to Profibus driver does not have specific meaning. Profibus ID is set by Gateway configuration software. (PLC2 settings/advanced) How other serial drivers work? Example1: Toshiba ASD In drivers like Toshiba ASD s, single parameter is read at a time. It does not allow multiple parameters read. So in case of Toshiba ASD s driver concept of Internal Database* is not used. Example2: Toshiba PLC Since drivers like Toshiba PLC, Modbus allow multiple register reading in one block, in this case concept of Internal Database* is used. * Note: Concept of Internal database (IDB) is explained on next page. 40
41 Note on Communication Drivers Let us have a glance at Internal database. Please refer the following example. 41
42 Note on Communication Drivers According to the project defined in Gateway software, the Gateway software automatically generates its own IDB, (Gateway drivers use this IDB for optomized communication.) as explained below. 1. Registers required for a project are grouped in a block of registers (calculation based optimized block) and entire block is read (By Gateway) in one cycle instead of reading individual registers. 5 words from , 10 words from , 18 words from are grouped in one block. (Please refer the first block, IDB FOR COM1) 25 words from , 3 words from are grouped in one block. (Please refer second block,idb FOR COM1) These blocks are uploaded/read in continuous fashion (in the background by Gateway driver) and data is stored in internal database memory. So time required for read cycle is optimized. 2. Write operations are on comparison basis. Since all the registers data is already present in internal database memory of Gateway driver, every time before performing write operation data is compared with the internal memory data. In this way unnecessary write operations can be avoided. The PLC2 driver uses this data whenever needed according to gateway project. The Internal database is associated only with Master drivers. Every Master driver has its own internal database of 3KBytes. Data fetched by the master driver from external slave device is loaded into its internal memory in continuous fashion irrespective of block execution of Gateway project. Background communication Enable/Disable default setting depends on PLC or Device protocol. The speed of data transfer is improved because of Internal database since it reduces the number of block executions required by the Gateway software. Background communication can be set by PLC1 settings/advanced/background Communication. 42
43 Note on Communication Drivers Background Read Operation Write Operation Write in Internal Memory Gateway Slave Device Master Driver 3KBytes Internal Database Profibus DPV0 Driver Write in External serial device Compare Figure 1 explains the operation of Master-Master mode with background communication. At power on each master driver will get all inputs from their internal database Setup and according to that information starts fetching and loading data into its internal database memory irrespective of execution of project blocks. The master driver will read all the data and load it into the internal database memory. But in case of write operation, each master driver will check the data available in the internal memory with the new data to be written. If the data in the internal memory is same as the new data, then Gateway software will skip the write command. In case of different data, master driver will initiate the write command. 43
44 Typical Projects In this chapter.... TYPICAL PROJECTS Project Setup Connect Toshiba Inverter as Profibus DPV0 Slave on Profibus Network with GWY-500-B Connect Modicon PLC as Profibus DPV0 Slave on Profibus Network with GWY-500-B Connect SCADA Software on Profibus Network 44
45 Typical Projects 6.1 Project Setup This Chapter explains, how a simple Gateway project can be created and tested. To develop a Gateway system, select appropriate Gateway model depending on the system requirements. A new project can be created as follows: 1. Define the Gateway System: 1.1 Protocol of Device(s) connected to PLC1 1.2 Protocol of Device(s) connected to PLC2 2. Load Microsoft Windows based Gateway Setup software. 3. Select devices to be connected on two ports. 4. Define Blocks for data transfer. 5. Set the communication parameters for the selected devices. 6. Set conditions for block execution if required (Repeat Cycle, Control Word etc.) 7. Apply power to Gateway. 8. Download the Project and Communication Drivers into Gateway. 9. Remove Configuration Cable from PLC1 Connect Gateway - Device cable to PLC1 10. Test system. Following Gateway examples show detailed setup for common Gateway configurations: 45
46 Typical Projects 6.2 Connect Toshiba Inverter as Profibus DPV0 Slave on Profibus Network with GWY-500 This project reads the parameters of Inverter connected on COM1 and writes the parameters to PLC / Controller connected on COM2 and vice versa. COM1 Protocol: Toshiba S11 COM2 Protocol: Profibus Both thses Protocols does not need IDB. 46
47 Typical Projects The block execution of the project is as follows: Block#1: The current output frequency of the inverter is read and updated in I000. Block#2: The current output power of the inverter is read and updated in I001. Block#3: The Acceleration time1 of the inverter is read and updated in I002. Block#4: The Decelaration time1 of the inverter is read and updated in I003. Block#5: The output voltage of the inverter is read and updated in I004. Block#6: The current of the inverter is read and updated in I005. Block#7: The error history code of the inverter is read and updated in I006. Block#8: The value of O000 is set as command frequency of the inverter. Block#9: According to the value of O001, the inverter is Run / Stop. Block#10: The value of O002 is set as Acceleration time1 of the inverter. Block#11: The value of O003 is set as Decelaration time1 of the inverter. Block#12: According to the value of O004, the direction (Forward/ Reverse) of the inverter is changed. 47
48 Typical Projects 6.3 Connect Modicon PLC or other Modbus Slave devices as Profibus DPV0 Slave on Profibus Network with GWY-500-B COM1 Protocol: Modbus Master COM2 Protocol: Profibus DPV0 Slave 48
49 Typical Projects The block execution of the project is as follows: Block #1: Gateway reads 16 words starting from from Modbus and write these 16 words data to internal memory of Profibus (Input area). Block #2: Gateway reads 16 words starting from O000 in internal memory of Profibus (Output area) and writes it to holding register starting from
50 Typical Projects 6.4 Connect SCADA Software on Profibus Network COM1 Protocol: Modbus Slave COM2 Protocol: Profibus DPV0 Slave 50
51 Typical Projects Connect SCADA device on Port1. With the help of GWY-500 SCADA device can act as Profibus DP Slave on Profibus Network. Block #1 maps 100 words of Modbus starting from to Profibus starting from O000. Block #2 maps 100 words of Modbus starting from to Profibus starting from I000. Note: I000 is the first word of Input Area in Internal Memory of Profibus driver. O000 is the first word of Output Area in Internal Memory of Profibus driver. 51
52 Configuration Software In this chapter... CONFIGURATION SOFTWARE System Requirements Installation Instruction 52
53 Configuration Software 7.1 System Requirements System Requirement for Gateway setup software are: Windows Version: Processor: Hard disk Space: Serial Mouse: RAM: Display resolution: Display colors: Microsoft Windows XP / 2000, Windows 7 / VISTA (32/64 bits) PENTIUM or higher 5 MB or more Required 64 MB or more 800 X 600 (VGA) or better 16 bit color 7.2 Installation Instruction Use the following procedure to install the Microsoft Windows based Gateway setup software This installation shows the procedure to install the software from a CD Disk on drive E. On machines with different drive configurations, change the names as needed. It is recommended that a backup disk of the Gateway setup software disk be created and stored in a safe place. 1. Launch the Windows operating system. 2. Insert the setup CD into CD-drive. 3. Point to the start button then click RUN 4. In the command line box enter E:\Disk1\setup.exe. Click OK. This will launch the Gateway installer. 5. Follow the instructions to complete setup. Gateway Project: Each Gateway must be configured before connecting it to the PLC. Gateway configuration software allows the following: 1. Create a new Gateway project - Select protocols for both communication ports of gateway. - Create blocks for data to be shared. - Set Communication Parameters for both the ports. - Set Control Word. (Optional) - Set Error Indication Bit, etc. (Optional) 2. Downloading. - Download Project - Download drivers - Download new firmware, if required (only for upgrading). 3. Upload Project. The existing project in the gateway module can be viewed/edited. 4. Upload System Data. This option enables viewing of version number, status of firmware, drivers used, and boot block. 53
54 Creating Project In this chapter.... PROFIBUS MASTER SETUP Setup of GWY-500-B withomron Profibus master Setup of GWY-500-B withsiemens Profibus master 54
55 Creating Project 8.1 Setup Of GWY-500 with Omron Profibus Master For Profibus communication, user needs the software Cx-Profibus. You need to enter the password as password (default), you can also change that. The steps for configuration of Profibus network are as follows 55
56 Creating Project 1 First install the GSD file for Profibus slave module. View Device Catalogue Install GSD file 56
57 Creating Project 2 Then user should form the network that consists of master and slave module. Select the module - Add Device to the network 57
58 Creating Project 58
59 Creating Project 3 Profibus slave module is configured as follows. (a) In Configuration tab, configure the Input and Output modules. 59
60 Creating Project (b) In Parameter tab, keep it to common. 60
61 Creating Project (c) In Group tab, assign the group for the slave, for global commands. 61
62 Creating Project 62
63 Creating Project 4 Now configure Profibus master module as shown below 63
64 Creating Project 64
65 Creating Project You can change the baud rate in Bus Parameter tab. In Omron master, some area is assigned for Input (Input to Master) and Output (output from master). 65
66 Creating Project In case of this project, it is CIO3300 for Input and CIO3200 for output. The type of PLC and communication port, Baud Rate should be specified in Device setup tab Configure Device Type Settings Configure Network Type Settings 66
67 Creating Project User can test the configuration by clicking the Test Tab. After TEST, you should see the following in the Device Information Item OMRON Corporation Description Firmware Version Description This is fixed text, indicating the Manufacturer of the PROFIBUSDP Master Unit. This string will contain the name of the Unit, i.e. CJ1W-PRM21 or CS1W-PRM21. This string displays the firmware version, currently in the PROFIBUS-DP Master Unit. 67
68 Creating Project 5 Download the parameters in PLC. 6 When The Slave starts communicating with master, the COMM led gets on. 7 User can watch the area CIO3200 and CIO3300 with help of CX- Programmer 68
69 Creating Project 8.2 Setup Of GWY-500 with Siemens Profibus Master 01. Open A Simatic Manager You are getting a window with a name [Step 7 wizard: New Project ] Click on Next. Now select proper CPU & MPI add and then click on Next. Again click Next Now if you want to change project name, you can change otherwise remains as it is and then click on Finish You are getting a window with lots of options, Like -> Simatic 300 station -> CPU DP (1) [Name of selected CPU]. -> S7 Program etc.. Now click on Simatic 300 station. Now double click on Hardware. 02. Now you are getting a window with a name, Simatic 300 configuration_s7_pro_31. S7_Pro_31? Name of a file. 69
70 Creating Project 03. Then delete the CPU no. which is present in a window (0) UR comes under Simatic 300-configuration window. 04. You will see a window shown below. 70
71 Creating Project 05. Now install GSD file Path of GSD file: C:\Program Files\Gateway 3.11\GWY-500 (Profibus Gateway)\GSD. This is the default path. The actual path is where the user has installed Gateway Setup Software. 71
72 Creating Project 06. Now drag proper CPU (Siemens CPU) from Hardware Catalog Window to Hardware configuration window. Parameter Setting Network Setting 01. Transmission Rate e.g. 12 Mbps. 02. Profile DP 1 72
73 Creating Project 1 73
74 Creating Project 07. Now drag GWY-xxx from Hardware Catalog Window to HW configure Window. Give a proper address to profibus, which should be in between because Siemens PLC range is whereas VF- S11 Toshiba Inverter range is
75 Creating Project 08. Then go to, Option Configure Network. You are getting a window with a name Netpro S7_pro_31. S7_Pro_31 Name of a file. (If Catalog window not appears on screen the click a button that is present at the left side of exclamation mark.) 09. Now drag GWY-xxx from Hardware Catalog to Netpro window. 10. Click on GWY-xxxx which is shown below, (5) GWY-xxxxx DP-NORM You are getting a table, which is related, with GWY-xxxx. You have to do a program in it. 75
76 Creating Project Important Note: A slot has to be filling up from slot no.1. You can t leave blank slot in between. 76
77 Creating Project 11. After completion of program, download that program to PLC (Siemens PLC). 77
78 Creating Project 12. After downloading project to PLC, Go to, Simatic Manager Window PLC Display Accessible Node. 78
79 Creating Project 13. Then, Go to, PLC Monitor/Modify Variables. Before it 1st MPI=2 and the click on PLC. You get a window, whose name is, Var_Variable_Table1/2/3 Table1/2/3 Name of a table. 79
80 Creating Project 14. Give the proper Input word (IW) and Output word (OW) addresses which corresponds to the program created in GWY software and program created for Profibus. Just observe the three windows, which are shown below. From these three windows you will easily find out how a program is done and what is relation of being this three windows together. 15. After this communication should takes place in between PLC and Toshiba inverter via Profibus Option Card. 80
81 Applications In this chapter.... APPLICATIONS Possible Applications using GWY-500-B 81
82 Applications 9.1 Possible Applications of GWY-500-B 1.PLC To PLC Communication PLC1 X Protocol GWY-500-B Profibus-DP Protocol PLC2 Profibus Master 2. PLC as a Slave in Profibus Network Node 1 ~ Drive Motor PLC Profibus-DP Protocol GWY-500-B X Protocol PLC1 PLC PLC (Profibus Master) Node n Node 2 PID Controller 3. PLC (Profibus Master) as a Slave in Modbus Network Node 1 A S T R A 50 RPM (x10) Modbus Protocol GWY-500-B Profibus-DP Protocol PLC PLC (Profibus Master) Node 2 Drive Motor HMI Software ASTRA by Renu Electronics (Modbus Master) PLC Node n 82
83 Applications 4. Add I/O to your PLC Node 1 EAGLE-0800 Node n EAGLE-0800 ~ Modbus Protocol GWY-500-B Profibus-DP Protocol PLC Profibus Master Eagle Analog I/O Example: Eagle0800 by Renu Electronics * Images not to scale. 83
84 Cable Diagrams In this chapter... CABLE DIAGRAMS Communication Cables for GWY-500 IBM Cable for GWY
85 Cable Diagrams 10.1 Communication Cables TOSHIBA VF-S11 TO GWY-500 TOSHIBA VF-S11 SIDE GWY-500 SIDE 2 mtr. UNIT 8 PIN MODULAR CONNECTOR (CMOS) Shield Wire DB9 MALE (CMOS) SIGNALS Pin # Pin # SIGNALS 1 1 SG 2 2 RXD 3 3 RXD 4 4 CMOS TXD 5 5 SG CMOS TXD PIN MODULAR CONNECTOR PINOUTS FRONT VIEW Pin 1 (Left side) Shield Wire R.H.S. VIEW Pin 8 (Right side) 9 DB9 MALE PINOUTS Cable insert end Cable insert end 85
86 Cable Diagrams TOSHIBA T1 LINK PORT TO GWY-500 TOSHIBA T1 LINK PORT SIDE GWY-500 SIDE 2 mtr. UNIT WIRE OUTS SIGNAL FROM PLC Shield Wire DB9 MALE (RS485) SIGNALS Pin # Pin # SIGNALS RX+ YELLOW 1 TX+ TX+ GREEN 2 SG BLACK 3 RX- WHITE 4 RX+ TX- BLUE 5 SG TX- 9 RX- Shield Wire DB9 MALE PINOUTS
87 Cable Diagrams OMRON MASTER PROFIBUS PORT TO GWY-500 PROFIBUS PORT OMRON SIDE GWY-500 SIDE 2 mtr. ATTACH PLC UNIT DB9 MALE (RS485) Shield Wire DB9 MALE (RS485) SIGNALS Pin # Pin # SIGNALS B 3 3 B 4 4 SG 5 5 SG A 8 8 A 9 9 Shield Wire to DB9 body DB9 MALE PINOUTS
88 Cable Diagrams SIEMENS MASTER PROFIBUS PORT TO GWY-500 PROFIBUS PORT SIEMENS SIDE GWY-500 SIDE 2 mtr. ATTACH PLC UNIT DB9 MALE (RS485) Shield Wire DB9 MALE (RS485) SIGNALS Pin # Pin # SIGNALS B 3 3 B 4 4 SG 5 5 SG A 8 8 A 9 9 Shield Wire to DB9 body DB9 MALE PINOUTS
89 Cable Diagrams NS TO GWY-500 NS SIDE GWY-500 SIDE 2 mtr. ATTACH PLC UNIT DB9 MALE (RS232) Shield Wire DB9 MALE (RS232) SIGNALS Pin # Pin # SIGNALS 1 1 TXD 2 2 TXD RXD 3 3 RXD SG SG 9 9 Shield Wire to DB9 body DB9 MALE PINOUTS
90 Cable Diagrams THOMSON TECHNOLOGY CONTROLLER TO GWY-500 THOMSON TECHNOLOGY CONTROLLER GWY-500 SIDE 2 mtr. UNIT 8 PIN MODULAR CONNECTOR (RS485) Shield Wire DB9 MALE (RS485) SIGNALS Pin # Pin # SIGNALS RX+ 1 1 TX+ RX- 2 2 TX- 3 3 TX+ 4 4 RX+ GND 5 5 SG TX- 8 PIN MODULAR CONNECTOR PINOUTS FRONT VIEW R.H.S. VIEW Shield Wire 9 RX- DB9 MALE PINOUTS Pin 1 (Left side) Pin 8 (Right side) Cable insert end Cable insert end 90
91 Cable Diagrams OPTOMUX TO GWY-500 COM1 / PLC1 (RS232/RS485/CMOS) TX- TX+ RX- RX+ RX- RX+ TX- TX+ 91
92 Cable Diagrams YOKOGAWA CONTROLLER TO GWY-500 YOKOGAWA CONTROLLER SIDE GWY-500 SIDE 2 mtr. UNIT WIRE OUTS SIGNAL FROM PLC Shield Wire DB9 MALE (RS485) SIGNALS Pin # Pin # SIGNALS RX+ YELLOW 1 TX+ TX+ GREEN 2 SG BLACK 3 RX- WHITE 4 RX+ TX- BLUE 5 SG TX- 9 RX- Shield Wire DB9 MALE PINOUTS
93 Cable Diagrams AB SLC DH485 PORT TO GWY-500 (EC-P ) AB SLC SIDE GWY-500 SIDE 2 mtr. UNIT 8 PIN MODULAR CONNECTOR Shield Wire DB9 MALE SIGNALS Pin # Pin # SIGNALS A 1 1 TX+ B 2 A RX+ SG SHIELD SG B 8 TX- 8 PIN MODULAR CONNECTOR Shield Wire RX- FRONT VIEW R.H.S. VIEW DB9 MALE Pin 1 Pin Cable insert Cable insert 93
94 Cable Diagrams AB MICROLOGIX SERIES PLCs TO GWY-500 (EC-P-027A-00) AB MICROLOGIX SIDE GWY-500 SIDE 2 mtr. UNIT MINIDIN 8 PIN MALE (RS232) Shield Wire DB9 MALE (RS232) SIGNALS Pin # Pin # SIGNALS 1 1 SG 2 2 TXD 3 3 RXD RXD SG 6 6 TXD PIN MINIDIN CONNECTOR PINOUTS Shield Wire DB9 MALE PINOUTS
95 Cable Diagrams A B SLC DF1 PORT TO GWY-500 (EC-P-027B-00) AB SLC SIDE GWY-500 SIDE ATTACH PLC 2 mtr. UNIT DB9 FEMALE (RS232) Shield Wire DB9 MALE (RS232) SIGNALS Pin # Pin # SIGNALS 1 1 RXD 2 2 TXD TXD 3 3 RXD 4 4 SG 5 5 SG DB9 FEMALE PINOUTS Shield Wire to DB9 body DB9 MALE PINOUTS
96 Cable Diagrams OMRON CQM1 PLC TO GWY-500 (EC-P-006B-00) OMRON CQM1 SIDE GWY-500 SIDE 2 mtr. ATTACH PLC UNIT DB9 MALE (RS232) Shield Wire DB9 MALE (RS232) SIGNALS Pin # Pin # SIGNALS EARTH 1 1 TXD 2 2 TXD RXD 3 3 RXD SG SG 9 9 Shield Wire DB9 MALE PINOUTS
97 Cable Diagrams OMRON CQM/CPM CMOS PORT TO GWY-500 (EC-P-006A-00) OMRON CMOS SIDE GWY-500 SIDE OMRON TM C200H -CN422 2 mtr. UNIT OMRON 20 PIN CONNECTOR (CMOS) Shield Wire DB9 MALE (CMOS) SIGNALS Pin # Pin # SIGNALS RXD TXD CMOS SG Shield Wire DB9 MALE PINOUTS RXD SG TXD CMOS
98 Cable Diagrams 10.2 IBM Cables IBM CABLE FOR GWY-500 PC SIDE GWY-500 SIDE 2 mtr. IBM UNIT DB9 FEMALE (RS232) Shield Wire DB9 MALE (RS232) SIGNALS Pin # Pin # SIGNALS 1 1 RXD 2 2 TXD TXD 3 3 RXD 4 4 SG 5 5 SG Shield Wire DB9 FEMALE PINOUTS DB9 MALE PINOUTS 98
USER S MANUAL. Profibus Option Card For Toshiba VF-S11 Inverter
USER S MANUAL Profibus Option Card For Toshiba VF-S11 Inverter 1 Thank you for purchasing Profibus Option Card. This manual gives you a quick overview of the Profibus Option Card model. Read this manual
Lecture 4 Profibus. Urban Bilstrup [email protected]
Lecture 4 Profibus Urban Bilstrup [email protected] Profibus Outline Introduction Profibus-DP Physical Layer Link Layer Application Layer 2 Profibus Introduction Three different versions of PROFIBUS
GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0
GE Power Controls = FIELDBUS APPENDIX PROFIBUS DP = Doc. No.: ASTAT Plus PB_Appendix-v0 Fieldbus Appendix: PROFIBUS DP 1 Fieldbus Introduction...... 2 1.1 Introduction to Profibus-DP... 2 1.2 Network Overview...
Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master
Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master Page 1 of 13 Table of Contents 1 OVERVIEW... 3 2 INSTALLING AND CONFIGURING THE ANYBUS -X GENERIC GATEWAY AND ETHERNET
Moxa TCC-100/100I User s Guide
Moxa TCC-100/100I User s Guide Seventh Edition, June 2008 www.moxa.com/product 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. Moxa TCC-100/100I User s Guide The software
Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University
Practical steps for a successful PROFIBUS Project Presented by Dr. Xiu Ji Manchester Metropolitan University Basics of PROFIBUS Content Practical steps in the design and installation stages Segmentation:
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
Cat. No. W408-E2-02-X. CJ1W-PRT21 PROFIBUS-DP Slave Unit OPERATION MANUAL
Cat. No. W408-E2-02-X CJ1W-PRT21 PROFIBUS-DP Slave Unit OPERATION MANUAL CJ1W-PRT21 PROFIBUS-DP Slave Unit Operation Manual Produced January 2005 ii Notice: OMRON products are manufactured for use according
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
Universal Serial Bus (USB) to DH-485 Interface Converter
Installation Instructions Universal Serial Bus (USB) to DH-485 Interface Converter Catalog Number 1747-UIC Contents Overview..................................................3 Computer and Operating System
FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK
FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK Field busses are industrial control systems using Programmable Logic lers (PLC) to control and manage field devices found in industrial environments. The communication
RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
User Manual. Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP)
User Manual Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP) UMPCEA Rev 1.0, 05/2007 COPYRIGHT NOTICE This manual is a publication of Brainchild Electronics Co... Ltd.
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03
MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference : 9010709-03 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
Process Control and Automation using Modbus Protocol
Process Control and Automation using Modbus Protocol Modbus is the fundamental network protocol used in most industrial applications today. It is universal, open and an easy to use protocol. Modbus has
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide
RS-422/485 Multiport Serial PCI Card Installation Guide 21 Contents 1. Introduction...1 2. Package Check List...2 3. Board Layouts and Connectors...3 3.1 2S with DB9 Male Connectors...3 3.1.1 JP5: UART
Introduction to PROFIBUS and PROFINET
Introduction to PROFIBUS and PROFINET Andy Verwer Technical Officer for PROFIBUS UK Verwer Training & Consultancy Ltd Gold distributor PROFIBUS Characteristics PROFIBUS is a bi-directional digital communication
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
1-Port R422/485 Serial PCIe Card
1-Port R422/485 Serial PCIe Card Installation Guide 1. Introduction Thank you for purchasing this 1-Port RS422/485 Serial PCI Express (PCIe) Card. It is a universal add in card that connects to a PC or
SyncLink GT2/GT4 Serial Adapter
SyncLink GT2/GT4 Serial Adapter Hardware User s Manual MicroGate Systems, Ltd http://www.microgate.com MicroGate and SyncLink are registered trademarks of MicroGate Systems, Ltd. Copyright 2008 2012 MicroGate
IntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control
CPB. Doc. N MO-0279-ING MODBUS/PROFIBUS DP CONVERTER TYPE CPB. Microener - Copyright 2010 Date 20.12.2004 Rev. 0
MODBUS/PROFIBUS DP CONVERTER TYPE CPB Microener - Copyright 2010 Date 20.12.2004 Rev. 0 INDEX 1. GENERAL 3 2. CPB SET 4 3. INSTALLATION 4 3.1 - CPB CONVERTER ASSEMBLING 4 3.2 - PROFIBUS TERMINAL DESCRIPTION.
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
IntesisBox ASCII Server - LON
IntesisBox ASCII Server - LON Gateway for integration of LON devices into ASCII enabled control systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi
Manual Serial PCI Cards
Manual Serial PCI Cards W&T Models 13011, 13410 13411, 13610 13611, 13812 Version 1.4 Subject to error and alteration 37 01/2005 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make
PROFIBUS AND MODBUS: A COMPARISON
Real-Time Information for the Automation Professional TM PROFIBUS AND MODBUS: A COMPARISON By James Powell, Siemens October 2013 We live in a multi-protocol world and this will likely not change anytime
SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2
SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2 USER MANUAL Rev. P1.11 September 13, 2006 DeltaV is a trademark of Emerson Process Management, Inc Emerson Process Management, Inc. 1998,
USB to RS-422/485 Serial Adapter
USB to RS-422/485 Serial Adapter User Manual Ver. 2.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2
Modbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
Install the DeviceNet Module using the following procedure:
Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from
ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme 2015 - Alle Rechte vorbehalten
ALL-USB-RS422/485 USB to Serial Converter RS422/485 User Manual ALL-USB-RS422/485 USB to RS-422/485 Plugin Adapter This mini ALL-USB-RS422/485 is a surge and static protected USB to RS-422/485 Plugin Adapter.
Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7
1 de 7 1. Introduction This Technical Note explains how to configure the Modbus Gateway for Vantage Pro2. The Modbus Gateway allows the easy connection of a PLC (Programmable Logic Controller), RTU (Remote
User manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
User Manual IC-485AI 2002-09-27
User Manual IC-485AI Note: This equipment has been tested and found to comply ith the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
Modbus and ION Technology
70072-0104-14 TECHNICAL 06/2009 Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. PowerLogic ION meters are compatible
USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual
USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual 1 Copyright Statement No part of this publication may be reproduced in any form by any means without the prior written permission.
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
BACnet Automation Interface Module (Network Version)
Sense +V Tx Rx LAN LINK Over ARCNET KBaud BACnet Rx BACnet Tx Archive Valid Port S Tx Port S Rx Low Battery Network- Enhanced Access Default MSTP PTP = Download Required on Rnet and Port S IP Address IP
RS-485 Protocol Manual
RS-485 Protocol Manual Revision: 1.0 January 11, 2000 RS-485 Protocol Guidelines and Description Page i Table of Contents 1.0 COMMUNICATIONS BUS OVERVIEW... 1 2.0 DESIGN GUIDELINES... 1 2.1 Hardware Design
How To Use A 1232 On A 1236 On A Computer Or A Cell Phone
12-36-1000 Autodialler and Relay Telephone Interface 1.0 INTRODUCTION 12-36-1000 I/O Telephone Interface with AutoDialer The 12-36-1000 is a autodialer and telephone interface that can be used autonomously
User Manual. AS-Interface Programmer
AS-Interface Programmer Notice: RESTRICTIONS THE ZMD AS-INTERFACE PROGRAMMER HARDWARE AND ZMD AS-INTERFACE PROGRAMMER SOFTWARE IS DESIGNED FOR IC EVALUATION, LABORATORY SETUP AND MODULE DEVELOPMENT ONLY.
CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual
CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual CMC-0205820-01 Table of Content 1 Introduction to CMC-PD01... 2 1.1 Product Introduction... 2 1.2 Features... 2 2 Product Profile and Outline...
Bluetooth to Serial Adapter
Bluetooth to Serial Adapter Third Edition, Oct 2007 Version 3.0 771-BTS1009C3-001 Contents 1.0 Features....P.2 2.0 Package Content....P.2 3.0 Hard Drives Requirement.P.2 4.0 Specifications.P.3 5.0 Pin
INTMOD485-LH Protocol Converter
For Use with L-GAGE LH Series Sensors Features Converts an LH Network to the 485-RTU protocol Supports baud rates up to 230,400 baud Supports LH Networks with up to 32 sensors Model Protocol Conversion
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
Automation Unit TM 1703 ACP Flexible automation and telecontrol
Automation Unit Flexible automation and telecontrol Power Transmission and Distribution Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
Modbus and ION Technology
Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. ACCESS meters are compatible with Modbus networks as both slaves and
Omron I/O Driver (Series 2) Programmable Serial Interface Card
Omron I/O Driver (Series 2) Programmable Serial Interface Card USER MANUAL Rev. P1.55 June 8, 2012 DeltaV is a trademark of Emerson Process Management, Inc Emerson Process Management, Inc. 1998, 1999.
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.
IntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
Elettronica dei Sistemi Digitali Costantino Giaconia SERIAL I/O COMMON PROTOCOLS
SERIAL I/O COMMON PROTOCOLS RS-232 Fundamentals What is RS-232 RS-232 is a popular communications interface for connecting modems and data acquisition devices (i.e. GPS receivers, electronic balances,
Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd
Overview and Applications of PROFINET Andy Verwer Verwer Training & Consultancy Ltd What exactly is PROFINET? PROFINET is an open Industrial Ethernet standard developed by the PROFIBUS Organisation. PROFINET
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
Communication Unit 560CMU05 Data sheet
RTU560 product line Communication Unit 560CMU05 Data sheet E1 10/100 MB LAN E2 10/100 MB LAN CP1, CP2 RS232C or RS485 Ethernet Controller Ethernet Controller USART Processor bus MPU ELAN520 /Flash Memory
1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3
Contents Moxa Technical Support Team [email protected] 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements... 4 4 Configuration...
White Paper. Technical Capabilities of the DF1 Half-Duplex Protocol
White Paper Technical Capabilities of the DF1 Half-Duplex Protocol Introduction DF1 Protocol To meet the challenges of today s global marketplace communication and network, systems must offer customers
PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL
Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page
MACTek Corporation. USB HART Interface. Users Manual
MACTek Corporation USB HART Interface DM01003100AA February, 2003 LIMITED WARRANTY VIATOR Interface for HART MACTek Corporation warrants this Interface and all of its component against defects in materials
Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface
Options for ABB drives, converters and inverters User s manual FDPI-02 diagnostics and panel interface Table of contents Table of contents 3 1. FDPI-02 diagnostics and panel interface Safety..............................................
Application about Communication
Application about Communication Integration of ET200S PROFIBUS I/O in a Rockwell CompactLogix Controller Configuration Example Warranty, liability and support Note The application examples are not binding
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
Operation and Installation Manual
Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control
ATS Communication Overview
ATS Communication Overview Viewpoint ATS 485 Communication link IBM Compatible Slide 1 of 23 Contents 1. Introduction 2. LonWork 3. Modbus Cards 4. Modbus Factory Configuration 5. Modbus Test Software
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system:
CP 342-5 FO Function The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61 158/61784, master or slave) PG/OP communication S7
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
EDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
Bus modules systron PM
E031006 000823 Bus modules systron PM Bus systems Many bus systems have been developed to accommodate PLCs and associated modules made by specific manufacturers. However, due to diversified application
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
Cat. No. W01E-EN-02. PRT1-SCU11 PROFIBUS-DP Gateway to Host Link/Compoway-F OPERATION MANUAL
Cat. No. W01E-EN-02 PRT1-SCU11 PROFIBUS-DP Gateway to Host Link/Compoway-F OPERATION MANUAL PRT1-SCU11 PROFIBUS DP Gateway Operation Manual Revised September 19, 2005 iv Notice: OMRON products are manufactured
Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
LDG DTS-4/4R Desktop Coaxial Switch / Remote
LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
Kvaser Mini PCI Express User s Guide
Kvaser Mini PCI Express User s Guide Copyright 2013-2014 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Sunday 28 th September, 2014 We believe that the information contained herein was accurate
MANUAL FOR RX700 LR and NR
MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical
applicomio Profibus-DP
BradCommunications Profibus-DP network interface cards allow deterministic I/O data acquisition for PC-based control applications. Features New! Support of Windows 32-bit and 64-bit (WoW64) Support of
DK40 Datasheet & Hardware manual Version 2
DK40 Datasheet & Hardware manual Version 2 IPC@CHIP DK40 Evaluation module Beck IPC GmbH http://www.bcl.de page 1 of 11 Table of contents Table of contents... 2 Basic description... 3 Characteristics...
TTL to RS232 Adapter User Guide
TTL to RS232 Adapter User Guide Revision D March 28, 2011 Document Part Number GC-800-313d Copyright and Trademark Copyright 2006-2011, Grid Connect, Inc. All rights reserved. No part of this manual may
Development of a Gateway to PROFIBUS for Remote Diagnostics
Development of a Gateway to PROFIBUS for Remote Diagnostics Hassan Kaghazchi, Donal Heffernan Automation Research Centre, University of Limerick, Ireland Abstract With the increased use of fielbuses in
MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)
Installation and Maintenance Manual IM 852 Group: Controls Part Number: IM 852 Date: June 2007 Supercedes: New MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
2-Port RS232/422/485 Combo Serial PCI Card
2-Port RS232/422/485 Combo Serial PCI Card Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial PCI Card. It is a universal add in card that connects to a
Paragon Explorer Lite Communication Software
CU-111 APRIL 11, 2013 Paragon Explorer Lite Communication Software For Fireye Paragon Scanners using Windows XP DESCRIPTION Paragon Explorer Lite, is the basic PC based configuration tool for Paragon model
G3 Series PROFIBUS DP Technical Manual
G3 Series PROFIBUS DP Technical 3835063 A - Table of Contents PAGE About PROFIBUS-DP...3 Overview...3 G3 PROFIBUS-DP Features...3 Cabling and Drop Line Lengths (as defined by PROFIBUS specification)...3
S-series DeviceNet Interface Card
January 2013 Page 1 The DeltaV provides the solution for interfacing to discrete actuators and sensors. Offers freedom to choose appropriate bus for application Supports standard device-level busses Reduces
OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder
P R O D U C T G R O U P OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder Manual # 600-0901 November 30, 1999 Rev. D - 99068 DESCRIPTION The ST-888 Mobilecall Display Decoder is a desktop
Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G 3891 0020
Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G 3891 0020 Built-in Dupline channel generator PROFIBUS-DP slave according to EN 50 170 Certified by the PNO PROFIBUS-DP communication
Series Six Plus Programmable Controller
Series Six Plus Programmable Controller Gl?K-0147B June 1989 Central Processor Unit 8-Slot Rack 1l-Slot Rack General Description The Central Processor Unit (CPU) for the Series Six Plus Programmable Logic
Siemens AG 2010. Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.
Fieldbus solutions with the SIMATIC PCS 7 distributed control system Brochure April 2010 SIMATIC PCS 7 Answers for industry. Fieldbus solutions with SIMATIC PCS 7 OS multi-clients Engineering station Maintenance/