USB-Serial Conversion Cable User's Manual
|
|
|
- Mitchell Jefferson
- 9 years ago
- Views:
Transcription
1 Cat. No. W417-E1-03 USB-Serial Conversion Cable User's Manual
2 USB-Serial Conversion Cable User's Manual
3 Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property. DANGER WARNING Caution Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. OMRON Product References Visual Aids All OMRON products are capitalized in this manual. The word Unit is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation Ch, which appears in some displays and on some OMRON products, often means word and is abbreviated Wd in documentation in this sense. The abbreviation PLC means Programmable Controller. PC is used, however, in some Programming Device displays to mean Programmable Controller. The following headings appear in the left column of the manual to help you locate different types of information. Note Indicates information of particular interest for efficient and convenient operation of the product. OMRON, ,2, Indicates lists of one sort or another, such as procedures, checklists, etc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication. 2
4 TABLE OF CONTENTS TABLE OF CONTENTS Notice:...2 OMRON Product References... 2 Visual Aids... 2 TABLE OF CONTENTS... 3 About this Manual... 4 PRECAUTIONS... 5 Overview and Components... 8 Overview... 8 Appearance and Component Names... 8 Packing Lists... 9 Cable ()... 9 Specifications Compatible Operating Systems Compatible Software Applications Compatible PLCs, PTs and Programmable Relay Connection Configurations General Specifications Dimensions Cable System Configuration CS/CJ-series PLCs C-series PLCs CVM1 and CV-series PLCs PTs (NS and NT Series) Programmable Relay (ZEN) USB to PLC/PT Connection Tables Connecting with the ( Cable) Application Procedure Cable Connections Connecting the Cable Installing the Drivers Uninstalling the Drivers Connecting Online from the CX-Programmer Using More than One Conversion Cable Revision History Index
5 About this Manual About this Manual Thank you for purchasing the USB-Serial Conversion Cable. The USB-Serial Conversion Cable connects an OMRON PLC (or PT) to a personal computer's USB port. Please read this manual carefully and be sure you understand the information provided before attempting to install or operate the USB-Serial Conversion Cables. Be sure to read the precautions provided in the following section. Precautions provides general precautions for using the USB-Serial Conversion Cables and related devices. Overview and Components describes the parts of the USB-Serial Conversion Cables and gives an overview of their application. Packing Lists shows the various items that come with the USB-Serial Conversion Cables. Specifications provides the hardware and software specifications. Dimensions shows external cable dimensions. System Configuration shows the application of the USB-Serial Conversion Cables with various models of PLC. USB to PLC/PT Connection Tables lists the possible combinations of Cables, Units, and ports that can be used. Application Procedure gives an overview of the steps required to use USB-Serial Conversion Cables. DIP Switch Settings and Cable Connections describes switch settings and cable connections. Installing the Drivers tells how to install the software drivers. Uninstalling the Drivers tells how to uninstall the software drivers. Connecting Online from the CX-Programmer tells how to connect to a PLC or PT from a computer running the CX-Programmer. WARNING Failure to read and understand the information provided in this manual may result in personal injury or death, damage to the product, or product failure. Please read each section in its entirety and be sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given. 4
6 PRECAUTIONS PRECAUTIONS This section provides general precautions for using the USB-Serial Conversion Cable and related devices. The information contained in this section is important for the safe and reliable application of the USB-Serial Conversion Cable. You must read this section and understand the information contained before attempting to set up or operate a USB-Serial Conversion Cable and PLC system. Intended Audience This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent). Personnel in charge of purchasing FA devices. Personnel in charge of designing FA systems. Personnel in charge of managing FA systems and facilities. General Precautions The user must operate the product according to the performance specifications described in the operation manuals. Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly. This manual provides important information for using the USB-Serial Conversion Cable. Be sure to read this manual before attempting to use the Conversion Cable and keep this manual close at hand for reference during operation. WARNING It is extremely important that a PLC and all PLC Units be used for the specified purpose and under the specified conditions, especially in applications that can directly or indirectly affect human life. You must consult with your OMRON representative before applying a PLC system to the above mentioned applications. Operating Environment Precautions Do not use the USB-serial Conversion Cable in the following places: Locations subject to strong electromagnetic fields. Locations subject to direct sunlight. Locations subject to temperatures or humidity outside the range specified in the specifications. Locations subject to condensation as the result of severe changes in temperature. Locations subject to corrosive or flammable gases. Locations subject to excessive dust, or salts, or metal filings. Locations subject to exposure to water, oil, or chemicals. Locations subject to shock or vibration. Provide proper shielding when installing in the following locations: Locations subject to static electricity or other sources of noise. Locations subject to strong electromagnetic fields. Locations subject to possible exposure to radiation. Locations near power supply lines. 5
7 PRECAUTIONS Application Precautions Observe the following precautions when using the USB-Serial Conversion Cable. These cables are designed specifically to connect a personal computer to an OMRON PLC or PT. Do not use them to connect any other devices and do not use a commercially available USB-serial conversion cable in place of these cables. Improper usage of these cables may result in damage to external devices, the PLC, or the PT. Do not attempt to disassemble, repair, or modify any Units. Touch a grounded metal object to discharge any static electricity before connecting the Conversion Cable to the PLC's connector, a PLC Connecting Cable, or the personal computer's USB port. To avoid malfunctions due to noise, do not route the Conversion Cable parallel or close to a high-tension power line. Tighten the D-sub connector screws to a torque of 0.4 N m. Either turn OFF the power supply to the computer or disconnect the cable from the USB connector before setting the DIP switch. Always lock any connectors that are equipped with locking mechanisms. Do not place anything on the cable. Do not bend the cable past it's normal bending radius or pull on the cable. Touch the Unit only after touching a grounded metal object to release static electricity from your body. Disconnect or connect the cable only after confirming that communications are not in progress. Do not quickly and repeatedly connect and disconnect the USB connector. Doing so may cause the computer to malfunction. It may take some time for the computer to detect the cable after the cable is connected. This is not a malfunction. Do not connect the RS-232C connector on the Cable (D-sub type) directly to the RS-232C or RS-422/485 connector on the PLC. The cable may malfunction. Do not connect this cable to a USB hub; connect it directly to a USB connector on the computer. The cable may malfunction. Do not extend the USB portion of this cable with an extension cable. The cable may malfunction. Set the communications port (COM port) number used by the software to the communications port (COM port) number allocated to the Conversion Cable. Caution Perform wiring so that the power supply wires are not exposed and do not come into contact with any metal parts. Contact with metal parts may cause a fire. 6
8 PRECAUTIONS EC Directives Applicable Directives EMC Directives Low Voltage Directive Concepts EMC Directives OMRON devices that comply with EC Directives also conform to the related EMC standards so that they can be more easily built into other devices or the overall machine. The actual products have been checked for conformity to EMC standards (see the following note). Whether the products conform to the standards in the system used by the customer, however, must be checked by the customer. EMC-related performance of the OMRON devices that comply with EC Directives will vary depending on the configuration, wiring, and other conditions of the equipment or control panel on which the OMRON devices are installed. The customer must, therefore, perform the final check to confirm that devices and the overall machine conform to EMC standards. Note: Within the EMC (Electromagnetic Compatibility) standards, the applicable EMS (Electromagnetic Susceptibility) standard is EN and the applicable EMI (Electromagnetic Interference) standard is EN (10-m regulations.) Low Voltage Directive Always ensure that devices operating at voltages of 50 to 1,000 VAC and 75 to 1,500 VDC meet the required safety standards (EN ). Conformance to EC Directives The USB-Serial Conversion Cables comply with EC Directives. Observe the following precautions to ensure that the machine or device in which the Conversion Cable is used complies with EC directives: 1. The USB-Serial Conversion Cable must be installed within a control panel. 2. Reinforced insulation or double insulation must be used for the DC power supplies providing the communications power supply and I/O power supplies. 3. USB-Serial Conversion Cables complying with EC Directives also conform to the Common Emission Standard (EN ). Radiated emission characteristics (10-m regulations) may vary depending on the configuration of the control panel used, other devices connected to the control panel, wiring, and other conditions. You must therefore confirm that the overall machine or equipment complies with EC Directives. 7
9 Overview and Components Overview and Components Overview The USB-Serial Conversion Cable connects an OMRON PLC (Programmable Controller) or PT (Programmable Terminal) to a personal computer's USB port. The cable can be used once the required drivers (on the provided CD-ROM) have been installed in the personal computer. The Conversion Cable can be used with OMRON PLC/PT software, such as the CX-Programmer, which use the CX-Server or FinsGateway as a communications driver, as well as other OMRON Software, such as the DeviceNet Configurator. Appearance and Component Names Cable (USB Connector to ) USB connector (A plug connector, ) D-Sub 9-pin connector () LED Indicators Indicator Color Status Description TD Yellow Flashing Data is being sent from the USB-Serial Conversion Cable. OFF Data is not being sent from the USB-Serial Conversion Cable. RD Yellow Flashing The USB-Serial Conversion Cable is receiving data. OFF The USB-Serial Conversion Cable is not receiving data. 8
10 Packing Lists Packing Lists Cable () Name (USB Connector to Conversion Cable) Drivers (On CD-ROM) User's Manual (this manual) (On CD-ROM in PDF format) Appearance Instruction Sheet 9
11 Specifications Specifications Compatible Operating Systems Windows 98/ME/2000/XP/Vista Compatible Software Applications The compatible software applications communicate with the PLC using the CX-Server or FinsGateway. The following software applications use CX-Server or FinsGateway. Name Communications software CX-Programmer CX-Server (FinsGateway is used for network communications.) CX-Simulator FinsGateway CX-Protocol CX-Server (FinsGateway is used for network communications.) CX-Position FinsGateway CX-Motion CX-Server CX-Process FinsGateway or CX-Server NS-Designer FinsGateway PLC Reporter FinsGateway The following software applications are also compatible. DeviceNet Configurator NT Support Tool for Windows ZEN Support Software Ver. 3.0 or later Software applications in CX-One Communications Port Limitations with the NT Support Tool 1) Version 4.00 and Earlier Versions Only communications ports COM1 and COM2 can be used. Always change the communications port allocation for this device to COM1 or COM2 in the Microsoft Windows Device Manager (see note 1) and specify that port in the NT Support Tool's communications settings. Once the communications port is specified correctly in the Windows Device Manager and the NT Support Tool's communications settings, data such as screen data can be downloaded to the PT or uploaded from the PT through the USB-Serial Conversion Cable. Note: In most personal computers, COM1 is allocated to the RS-232C port and communications port COM2 can be allocated to the Conversion Cable. Refer to Changing the Allocated Communications Port on page 36 for details on changing the communications port. Furthermore, if there is another driver using the allocated port, that driver must be uninstalled. 2) Version 4.60E and Later Versions Any communications port between COM 1 and COM8 can be used. Check the NT Support Tool's communications settings and verify that the communications port allocated to the Conversion Cable is also specified in the NT Support Tool. 10
12 Specifications Limitations when Using the NT Support Tool's System Installer 1) Windows 98 and Windows Me The system program cannot be downloaded to the PT through the USB-Serial Conversion Cable. 2) Windows 2000, Windows XP, and Windows Vista Only communications ports COM1 and COM2 can be used. Always change the communications port allocation for this device to COM1 or COM2 in the Microsoft Windows Device Manager (see note 1) and specify that port in the NT Support Tool's communications settings. Once the communications port is specified correctly in the Windows Device Manager and the NT Support Tool's communications settings, the system program can be downloaded to the PT through the USB-Serial Conversion Cable. Note: In most personal computers, COM1 is allocated to the RS-232C port and communications port COM2 can be allocated to the Conversion Cable. Refer to Changing the Allocated Communications Port on page 36 for details on changing the communications port. Furthermore, if there is another driver using the allocated port, that driver must be uninstalled. Compatible PLCs, PTs and Programmable Relay The following OMRON PLCs, PTs and Programmable Relay are supported by the compatible software applications. PLCs CS/CJ-series, C-series (see note 1), and CVM1/CV-series PT NS-series and NT-series Programmable Relay ZEN (see note 2) Note 1. The following C-series PLCs are supported: C200HS, C200HX/HG/HE, C200H, C1000H, C2000H, CQM1, CPM1, CPM1A, CPM2A, SRM1, CQM1H, and CPM2C. Note 2. The ZEN Programmable Relay is supported only if ZEN Support Software Ver. 3.0 or later is used. 11
13 Specifications Connection Configurations The following table shows the connection configurations that can be used to connect an OMRON PLC (or PT) to a personal computer's USB port. USB-Serial Conversion Cable (D-sub version) Conversion Cable's serial connector D-sub 9-pin Required adapters or cables CS1W-CN226/626 (Programming Device Connecting Cable for a CS/CJ-series port and personal computer) XW2Z-200/500S-CV or XW2Z-200/500S-V (Programming Device Connecting Cable for an RS-232C port and personal computer) + CS1W-CN118 (RS-232C to CS/CJ-series port Conversion Cable) CQM1-CIF02 (Programming Device Connecting Cable for a C-series port and personal computer) + CS1W-CN114 (C-series port to CS/CJ-series port Conversion Cable) CQM1-CIF02 (Programming Device Connecting Cable for a C-series port and personal computer) RS-232C 9-pin to 25-pin adapter + CV500-CIF01 (Programming Device Connecting Cable for a CV-series port and PC98-type personal computer) XW2Z-200/500S-CV or XW2Z-200/500S-V (Programming Device Connecting Cable for an RS-232C port and personal computer) ZEN-CIF01 (Personal Computer Connecting Cable) Compatible PLC or PT connector CS/CJ-series port C-series port CV-series port RS-232C port (D-sub 9-pin) Personal Computer Connecting port Compatible PLCs and PTs CS/CJ-series, CQM1H, and CPM2C C200HS, C200HX/HG/HE, CQM1, CPM1, CPM1A, CPM2A, and SRM1 CVM1/CV-series PLCs (CPU Unit or Serial Communication Unit/Board connection) or PTs ZEN Note The USB-Serial Conversion Cables are for connections between a USB port and an OMRON PLC/PT only. In particular, the Cable can be used only with compatible OMRON software applications even though it has a standard D-sub 9-pin connector on one end. 12
14 Specifications General Specifications USB Interface rating Conforms to USB Specification 1.1 DTE speed kbps Connector specifications Computer end USB (type A plug, ) PLC end RS-232C ( ) Power supply Bus power (5 VDC power from upstream) Current consumption 35 ma Operating Ambient temperature 0 to 55 C environment Ambient humidity 10% to 90% humidity (with no condensation) Atmosphere No corrosive gases Weight 50 g 13
15 Dimensions Dimensions Cable (46) (11.75) 17.8 (8) (4.5) (12)
16 System Configuration System Configuration CS/CJ-series PLCs Connecting to the Peripheral Port Using a CS1W-CN226/626 Cable USB type A plug, (9-pin ) (9-pin ) CS/CJ-series PLC connection Customizable Counter Unit connection CS/CJ-series connector Peripheral port Recommended cable: CS1W-CN226/626 Using a CQM1-CIF02 Cable USB type A plug, (9-pin ) CS/CJ-series PLC connection (see note) CS/CJ-series (9-pin ) C-series connector connector Peripheral port Recommended cable: CQM1-CIF02 CS1W-CN114 Note: With a CS/CJ-series PLC, the connection must be a host link connection. 15
17 System Configuration Using a XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V Cable for an RS-232C Connection USB type A plug, (9-pin ) (9-pin ) CS/CJ-series PLC connection Customizable Counter Unit connection (9-pin ) Peripheral port XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V (See note.) (9-pin ) CS1W-CN118 CS/CJ-series connector Note: With a CS/CJ-series PLC, the connection must be a host link connection. Connecting to the RS-232C Port Using a XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V Cable for an RS-232C Connection USB type A plug, (9-pin ) CS/CJ-series PLC connection (9-pin ) (9-pin ) RS-232C port (9-pin ) Recommended cable: XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V (See note.) Note: With a CS/CJ-series PLC, the connection must be a host link connection. 16
18 System Configuration C-series PLCs C200HS, C200HX/HG/HE, C200H, C1000H, C2000H, CQM1, CPM1, CPM1A, CPM2A, or SRM1 Connecting to the Peripheral Port Using a CQM1-CIF02 Cable USB type A plug, (9-pin ) (9-pin ) C-series PLC connection C-series connector Peripheral port Recommended cable: CQM1-CIF02 Connecting to the RS-232C Port Using a XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V Cable for an RS-232C Connection USB type A plug, (9-pin ) (9-pin ) C-series PLC connection (9-pin ) RS-232C port (9-pin ) Recommended cable: XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V 17
19 System Configuration CQM1H and CPM2C PLCs Connecting to the Peripheral Port Using a CS1W-CN226/626 Cable USB type A plug, (9-pin ) (9-pin ) CQM1H PLC connection CPM2C PLC connection CS/CJ-series connector Peripheral port Recommended cable: CS1W-CN226/626 Using a CQM1-CIF02 Cable USB type A plug, USB type A plug, (9-pin ) (9-pin ) CQM1H PLC connection CPM2C PLC connection C-series connector CS/CJ-series connector Peripheral port Recommended cable: CQM1-CIF02 CS1W-CN114 Note: With a CS/CJ-series PLC, the connection must be a host link connection. 18
20 System Configuration Using a XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V Cable for an RS-232C Connection USB type A plug, (9-pin ) CQM1H PLC connection CPM2C PLC connection (9-pin ) (9-pin ) Peripheral port XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V CS/CJ-series connector (See note.) (9-pin ) CS1W-CN118 Note: With a CS/CJ-series PLC, the connection must be a host link connection. Connecting to the RS-232C Port Using a XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V Cable for an RS-232C Connection USB type A plug, (9-pin ) CQM1H PLC connection CPM2C PLC connection (9-pin ) (9-pin ) RS-232C port (9-pin ) XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V (See note.) Note: With a CS/CJ-series PLC, the connection must be a host link connection. 19
21 System Configuration CVM1 and CV-series PLCs Connecting to the Peripheral Port Using a CV500-CIF01 Cable USB type A plug, (9-pin ) D-sub 25-pin () to 9-pin () Adapter CVM1/CV-series PLC connection (25-pin ) CV-series connector Peripheral port Recommended cable: CV500-CIF01 Connecting to the RS-232C Port Using a XW2Z-200S-V/500S-V Cable USB type A plug, (9-pin ) CVM1/CV-series PLC connection (9-pin ) (9-pin ) RS-232C port (9-pin ) Recommended cable: XW2Z-200S-V/500S-V 20
22 System Configuration PTs (NS and NT Series) Connecting to the RS-232C Port Using a XW2Z-S002 Cable USB type A plug, (9-pin ) (9-pin ) D-sub Connector (9-pin ) PT connection XW2Z-S002 RS-232C port Programmable Relay (ZEN) USB type A plug, (9-pin ) (9-pin ) Personal Computer Connector ZEN Personal Computer Connecting Cable ZEN-CIF01 Personal Computer Connecting port 21
23 USB to PLC/PT Connection Tables USB to PLC/PT Connection Tables Connecting with the ( Cable) Computer Cable 1 Cable 2 (when necessary) PLC CS1W-N226/626 Programming Device Connecting Cable for a CS/CJ-series port OR CS1W-CN114 C-series port to CS/CJ-series port Conversion Cable USB Conversion Cable + CQM1H-CIF02 Programming Device Connecting Cable for a C-series port + CS1W-CN118 RS-232C to CS/CJ-series port Conversion Cable OR XW2Z-@@@ Programming Device Connecting Cable for RS-232C CS/CJ-series Units CS/CJ-series CPU Units USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) CS1W-CN226/626 (Length: 2 or 6 m) CS/CJ-series CQM1-CIF02 C-series (Length: 3.3 m) XW2Z-200S-CV /500S-CV XW2Z-200S-V /500S-V XW2Z-200S-CV /500S-CV XW2Z-200S-V /500S-V RS-232C RS-232C C-series CS1W-CN114 (Length: 5 cm) CS1W-CN118 (Length: 0.1 m) CS1W-CN118 (Length: 0.1 m) CS/CJ-series CS/CJ-series CS/CJ-series CS/CJ-series RS-232C Peripheral bus (Toolbus) or Host link (SYSWAY) Host link (SYSWAY) Peripheral bus (Toolbus) or Host link (SYSWAY) Host link (SYSWAY) Peripheral bus (Toolbus) or Host link (SYSWAY) Host link (SYSWAY) 22
24 USB to PLC/PT Connection Tables CS/CJ-series Serial Communications Board or Unit USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) XW2Z-200S-CV /500S-CV XW2Z-200S-V /500S-V RS-232C RS-232C Customizable Counter Unit RS-232C Host link (SYSWAY) USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) CS1W-CN226/626 CS/CJ-series CS/CJ-series Peripheral bus (Length: 2 or 6 m) (Toolbus) C-series Units XW2Z-200S-V /500S-V CS1W-CN118 (Length: 0.1 m) CS/CJ-series Note: In this table, the C-series refers to the C200HS, C200HX/HG/HE, C200H, C1000H, C2000H, CQM1, CPM1, CPM1A, CPM2A, SRM1, CQM1H, and CPM2C. C200HS, C200HX/HG/HE, CQM1, CPM1, CPM1A, CPM2A, and SRM1 Peripheral bus (Toolbus) USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) CQM1-CIF02 (Length: 3.3 m) XW2Z-200S-CV /500S-CV XW2Z-200S-V /500S-V C-series C-series RS-232C Peripheral bus (Toolbus) or Host link (SYSWAY) (See note.) Host link (SYSWAY) Note: The host link mode can be used in all of these PLCs, but the bus mode cannot be used in CPM2@ PLCs that have a 9 as the 4 th digit of the lot number. (The lot number may be 4 or 5 digits long.) C200H, C1000H, and C2000H CPU Units USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) CQM1-CIF02 (Length: 3.3 m) C-series C-series C200H-IP007 Built-in port Host link (SYSWAY) 23
25 USB to PLC/PT Connection Tables CQM1H CPU Units USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) CPM2C CS1W-CN226/626 (Length: 2 or 6 m) CQM1-CIF02 (Length: 3.3 m) XW2Z-200S-CV /500S-CV XW2Z-200S-V /500S-V XW2Z-200S-CV /500S-CV XW2Z-200S-V /500S-V CS/CJ-series C-series C-series CS1W-CN114 (Length: 5 cm) CS1W-CN118 (Length: 0.1 m) CS1W-CN118 (Length: 0.1 m) CS/CJ-series CS/CJ-series CS/CJ-series CS/CJ-series RS-232C Peripheral bus (Toolbus) or Host link (SYSWAY) Host link (SYSWAY) Host link (SYSWAY) USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) CQM1-CIF02 (Length: 3.3 m) CQM1-CIF02 (Length: 3.3 m) CS1W-CN226/626 (Length: 2 or 6 m) (See note 2.) XW2Z-200S-CV /500S-CV XW2Z-200S-CV /500S-CV XW2Z-200S-V /500S-V XW2Z-200S-V /500S-V C-series C-series CS/CJ-series C-series C-series CS1W-CN114 (Length: 5 cm) CS/CJ-series CPM2C-CN111 CS/CJ-series (Peripheral port connector) CS1W-CN118 (Length: 0.1 m) CPM2C-CN111 (RS-232C port connector) CS1W-CN118 (Length: 0.1 m) CPM2C-CN111 (RS-232C port connector) CS/CJ-series CS/CJ-series CS/CJ-series CS/CJ-series CS/CJ-series RS-232C Peripheral bus (Toolbus) or Host link (SYSWAY) (See note 1.) Host link (SYSWAY) Host link (SYSWAY) Note 1: The host link mode can be used in all of these PLCs, but the bus mode cannot be used in CPM2@ PLCs that have a 9 as the 4 th digit of the lot number. (The lot number may be 4 or 5 digits long.) Note 2: Only host link mode can be used. 24
26 USB to PLC/PT Connection Tables C-series Host Link Unit (C200H-LK201-V1 or C120-LK201-V1) Note: The Host Link Unit cannot be used to connect a Programming Device (such as the CX-Programmer) to a C200HX/HG/HE with the "-ZE" suffix at the end of the model number. USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) XW2Z-200P-V /500P-V D-sub 25-pin, RS-232C D-sub 25-pin, C-series Communications Board (C200HX/HG/HE PLCs Only) Host link (SYSWAY) USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) XW2Z-200S-CV /500S-CV XW2Z-200S-V /500S-V C200H, C1000H, and C2000H Host Link Units RS-232C D-sub 9-pin, Host link (SYSWAY) Note: The C500-LK203 and C500-LK 201-V1 Host Link Units can be used with the C1000H and C2000H. The C200H-LK201-V1 and C120-LK201-V1 Host Link Units can be used with the C200H. USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) XW2Z-200P-V /500P-V D-sub 25-pin, CQM1H Serial Communication Board RS-232C D-sub 25-pin, Host link (SYSWAY) USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) XW2Z-200S-CV /500S-CV XW2Z-200S-V /500S-V RS-232C D-sub 9-pin, Host link (SYSWAY) 25
27 USB to PLC/PT Connection Tables CVM1 and CV-series CVM1 and CV-series CPU Units USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) D-sub 25-pin () to D-sub 9-pin () adapter XW2Z-200S-V /500S-V D-sub 25-pin, CVM1 and CV-series Host Link Units CV500-LK201 (Port 1, Full-duplex mode) D-sub 25-pin, CV500-CIF01 (Length: 6 m) CV-series CV-series RS-232C D-sub 9-pin, Peripheral bus (Toolbus) Host link (SYSWAY) USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) XW2Z-200P-V /500P-V D-sub 25-pin, CV500-LK201 (Port 2, Full-duplex mode) RS-232C D-sub 25-pin, Host link (SYSWAY) USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) XW2Z-200S-V /500S-V RS-232C D-sub 9-pin, Host link (SYSWAY) PTs (NS or NT Series) USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) XW2Z-S002 (Length: 2 m) Programmable Relay (ZEN) RS-232C D-sub 9-pin, Host link (SYSWAY) USB Conversion Cable Cable 1 Cable 2 Unit's port Serial communications mode Model Connector Model Connector Connector Model Connector (Network type) ZEN-CIF01 (Length: 2 m) Personal Computer Connector Personal Computer port - 26
28 Application Procedure Application Procedure This section explains how to connect a PLC CPU Unit to a personal computer with a USB-Serial Conversion Cable. Use the procedure below when connecting a PLC CPU Unit and personal computer. The Conversion Cable uses one of the computer's COM ports for communications. When communicating with a PLC through a Conversion Cable, set the communications port (COM port) number used by the software to the communications port (COM port) number allocated to the Conversion Cable. 1. Connect the Cable(s). Connect the Conversion Cable to the computer's USB port and the CPU Unit's port or RS-232C port. For details, refer to Connecting the Cable on page Install the communications driver. The Conversion Cable's communications driver must be installed in the computer in order for the computer to use the Conversion Cable. For details, refer to Installing the Driver on page Turn ON the PLC's power. Turn ON the PLC's power supply. 4. Make an online connection to the CPU Unit through the computer software (when using the CX-Programmer.) Select the COM port in the CPU Unit from the CX-Programmer and connect online. For details, refer to Connecting Online from the CX-Programmer on page 34. Note More than one USB-Serial Conversion Cable can be used at a time, so a single personal computer can be connected to several PLCs/PTs through two or more COM ports. When more than one Conversion Cable is being used, connect the second and later Cables after the first Cable has been connected. The communications driver is automatically installed for the second and later Cables, so it is not necessary to install the driver a second time. Each Cable must have its own unique COM port number. Allocate a different COM port to each Cable. 27
29 Cable Connections Cable Connections Connecting the Cable Connect the computer and CPU Unit with one of the cable configurations shown in the USB to PLC/PT Connection Tables on page
30 Installing the Drivers Installing the Drivers When the USB-Serial Conversion Cable is connected to the computer, the operating system (OS) will recognize the Cable as a new device. At this point, the driver can be installed with the wizard. The actual driver installation method depends on the OS being used. Windows 2000 is used in the examples in this section. Note Note The USB-Serial Conversion Cables are compatible with Windows XP. When you install the Conversion Cable's driver, a warning message will appear indicating that the driver software has not passed Windows Logo testing, but click Continue Anyway to proceed with the installation. We have thoroughly tested the driver on Windows XP and verified the it operates properly. The driver will not be installed properly if the installation process is cancelled before completion. Normal communications may not be possible if the driver is not installed properly. If the driver is not installed properly, uninstall it (refer to page 33) and then reinstall it correctly. The USB-Serial Conversion Cables are compatible with Windows Vista. When you install the Conversion Cable's driver, a warning message will appear indicating that Windows can t verify the publisher of this driver software, but click Continue Anyway to proceed with the installation. We have thoroughly tested the driver on Windows Vista and verified that it operates properly. The driver will not be installed properly if the installation process is cancelled before completion. Normal communications may not be possible if the driver is not installed properly. If the driver is not installed properly, uninstall it (refer to page 33) and then reinstall it correctly. 1. The following window will be displayed. 2. The following window will be displayed. Click the Next button. The following window will be displayed. 29
31 Installing the Drivers 3. Select Search for a suitable driver for my device (recommended) and click the Next button. The following window will be displayed. Select Specify a location and click the Next button. The following window will be displayed. 4. Insert the CD-ROM containing the driver (the CD-ROM is in the same package as the Conversion Cable) into the computer's CD-ROM drive. Click the Browse button, select the ftdibus.inf file, from the following directory of the CD-ROM and click the OK button. Windows2000/XP/Vista: win2000_xp Windows98/Me: win98_me If the window's Copy manufacturer's files from field shows the correct folder, click the OK button. 5. The following window will be displayed. Click the Next button to start the installing the driver. 30
32 Installing the Drivers 6. The following window will be displayed if the driver was installed properly. Click the Finish button. 7. When the Finish button is clicked in step 6, the following window will be displayed for installation of the USB Serial Port driver. Follow the same procedure in steps 1 through 7 to install the USB Serial Port driver. (Driver installation is completed after installation of the USB Serial Port driver.) 8. Verify that the drivers were installed properly with the Windows Device Manager, as shown in the following diagram. To access the Device Manager, open the Control Panel, open the System folder, click the Hardware tab, and click the Device Manager button. 31
33 Installing the Drivers Verify that these two devices appear in the Device Manager. 32
34 Uninstalling the Drivers Uninstalling the Drivers Use the following procedure to delete (uninstall) the drivers for the USB-Serial Conversion Cable. 1. Disconnect the Conversion Cable from the computer. 2. Select Add/Remove Programs from the Control Panel. 3. Select OMRON USB-to-Serial Converter Drivers and click the Delete button. The following window will be displayed. 4. Click the Continue button. When the drivers have been successfully deleted, the message Uninstall complete, press Finish to exit will be displayed. 5. Click the Finish button. This completes the deletion (uninstallation) of the Conversion Cable's drivers. 33
35 Connecting Online from the CX-Programmer Connecting Online from the CX-Programmer The USB-Serial Conversion Cable uses one of the computer's COM ports to communicate. The communications port (COM port) allocated to the Conversion Cable must be selected with the CX-Programmer in order to connect online to a PLC or PT. Note: It may take some time for the computer to detect the cable after the cable is connected. This is not a malfunction. Selecting the Cable's COM Port in CX-Programmer Use the following procedure to select the COM port used by the Conversion Cable. 1. Display the Change PLC dialog box. 2. Click the Settings button in the Network Type area. Select the desired type of network. The Network Settings dialog box will be displayed. 3. Click the Driver tab in the Network Settings dialog box. 34
36 Connecting Online from the CX-Programmer 4. Locate the Port Name setting and select the COM port being used by the Conversion Cable. Note If you fail to connect with this USB Cable, turn OFF auto baud rate detection if it is being used by your software. With the CX-Programmer, auto baud rate detection can be turned OFF by clearing the selection for it on the Network Settings dialog box. Verifying the Allocated Communications Port The communications port (COM port) being used by the Conversion Cable can be verified with the following procedure. The actual verification procedure depends on the operating system. This example shows the procedure for Windows Open the Control Panel, open the System folder, and click the Hardware tab. 2. Click the Device Manager button. 3. Click the + symbol to the left of the Ports (COM & LPT) device icon to display the contents of that folder. Verify that there is an entry for the OMRON CS1W-CIF3* USB Serial Port (COM@) device. A communications port name will appear in parentheses. This is the communications port being used by the Conversion Cable. 35
37 Connecting Online from the CX-Programmer Changing the Allocated Communications Port The communications port (COM port) being used by the Conversion Cable can be changed with the following procedure. The actual change procedure depends on the operating system. This example shows the procedure for Windows Note If the new COM port is being used by another driver, that driver must be uninstalled. 1. Double-click OMRON CS1W-CIF3* USB Serial Port in the Device Manager window. 2. Click the Port Settings tab. 36
38 Connecting Online from the CX-Programmer 3. Click the Advanced button. The following window will be displayed. 4. Select the new COM port number from the COM Port Number list. 5. Click the OK button to change the COM port used by the Conversion Cable. 37
39 Using More than One Conversion Cable Using More than One Conversion Cable The operating system recognizes USB-Serial Conversion Cables individually. If a second Conversion Cable is connected after the driver has been installed, driver installation will be requested again. Install the driver from the CD-ROM again. If you do not own the CD-ROM and will use more than one Conversion Cable, copy the win2000_xp folder from the CD-ROM to a folder on your hard disk, and select this folder. Note: Use the following directory for Windows 98 or Me: Win98_Me 1. Copy the win2000_xp folder from the CD-ROM to your hard disk (the CD-ROM is in the same package as the Conversion Cable). 2. The following window will be displayed. Select Install from a list or specific location (Advanced) and click the Next button. 3. Click the Browse button next to the Include this location in the search field, select the win2000_xp folder copied from CD-ROM onto your hard disk, and click the Next button. 38
40 Revision History Revision History A manual revision code appears as a suffix to the catalog number on the front cover of the manual. Cat. No. W417-E1-03 Revision code The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version. Revision code Date Revised content 01 February 2003 Original production 02 October 2006 Page 7: Changed EMI standard number of EC Directives. Page 30: Changed the reference directory for the driver file. Page 37: Add section on using more than one Conversion Cable. 03 July 2007 Page 10: Changed the compatible operating systems. Page 29: Changed information on installing the drivers. 39
41 Index Index C communications port changing verifying component names... 8 configuration, PLC/PT connections C200HS, C200HX/HG/HE, C200H, C1000H/2000H, CQM1, CPM1, CPM1A, CPM2A, and SRM CQM1H, CPM2C CS/CJ-series PLCs C-series PLCs CVM1 and CV-series PLCs NS-series and NT-series PTs Programmable Relay (ZEN) CX-Programmer communications port D dimensions drivers installing uninstalling... 33, 38 O operating system, applicable overview... 8 P PLCs, applicable PTs, applicable S software, applicable
42 OMRON Corporation Control Devices Division H.Q. Shiokoji Horikawa, Shimogyo-ku, Kyoto, Japan Tel: (81) /Fax: (81) Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD Hoofddorp The Netherlands Tel: (31) /Fax: (31) OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL U.S.A. Tel: (1) /Fax: (1) OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore Tel: (65) /Fax: (65) OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, Pu Dong New Area, Shanghai, , China Tel: (86) /Fax: (86)
43 Authorized Distributor: Cat. No. W417-E1-03 Note: Specifications subject to change without notice Printed in Japan
Safety Precautions WARNINGS
Safety Precautions This guide contains a variety of safety markings related to the safe and correct operation of the USB Data Transfer Cable. Be sure to read this guide and any related manuals carefully
Introduction. - Please be sure to read and understand Precautions and Introductions in CX-Simulator Operation Manual and
Introduction - Please be sure to read and understand Precautions and Introductions in CX-Simulator Operation Manual and CX-Programmer Operation Manual before using the product. - This guide describes the
Cat. No. W463-E1-11. SYSMAC CX-One FA Integrated Tool Package CXONE-AL@@C-V4/AL@@D-V4 CXONE-LT@@C-V4 SETUP MANUAL
Cat. No. W463-E1-11 SYSMAC CX-One FA Integrated Tool Package CXONE-AL@@C-V4/AL@@D-V4 CXONE-LT@@C-V4 SETUP MANUAL SYSMAC CX-One FA Integrated Tool Package CXONE-AL@@C-V4/AL@@D-V4 CXONE-LT@@C-V4 Setup Manual
Universal Serial Bus (USB) to DH-485 Interface Converter
Installation Instructions Universal Serial Bus (USB) to DH-485 Interface Converter Catalog Number 1747-UIC Contents Overview..................................................3 Computer and Operating System
Cat. No. W317-E1-11 SYSMAC CPM1A. Programmable Controllers OPERATION MANUAL
Cat. No. W317-E1-11 SYSMAC CPM1A Programmable Controllers OPERATION MANUAL CPM1A Programmable Controllers Operation Manual Revised October 2007 iv Notice: OMRON products are manufactured for use according
Caplio Utility for Windows
Caplio Utility for Windows Operation Manual English To ensure correct use of the product, read this manual carefully before use. Keep the manual handy for future use. Introduction Thank you for purchasing
USB Driver Installation Manual [Windows Vista/Windows 7]
USB Communication Converter COM-K USB Driver Installation Manual [Windows Vista/Windows 7] NOV. 2010 R RKC INSTRUMENT INC. IMT01D10-E1 NOTICE This manual assumes that the reader has a fundamental knowledge
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
Package PLCs with Exceptional Cost
Package PLCs with Exceptional Cost»» Economy» Efficient Cost-Effective, Application, Application to Many Systems : 2 Ksteps DM Area : 2 Kwords Timers/Counters : 256 each Exceptional Cost Economy Responding
Installing PowerLink on Windows 7 64-bit
Instruction Manual Version 1.0, Code No. 20 751 806 1 Introduction... 3 2 Installing Virtual PC... 3 3 Configuring Windows XP Mode... 5 4 Installing Powerlink to Virtual XP... 8 5 Run PowerLink software
INDEX. Trademarks All name and product s trademarks mentioned below are the property of their respective companies.
USB2.0 EASY IDE ADAPTER INDEX Trademarks ---------------------------------------------------------------------------- Introduction ---------------------------------------------------------------------------
USB Flash Drive User s Manual
USB Flash Drive User s Manual V4.01 Introduction Thank you for your purchasing the USB Drive. This manual will guide you through the usages of the USB Drive and of all management tools coming with it.
Cat. No. W436-E1-10 SYSMAC CXONE-AL@@C-V4/ CXONE-AL@@D-V4. CX-Motion-NCF Ver. 1.9. Position Controller Software OPERATION MANUAL
Cat. No. W436-E1-10 SYSMAC CXONE-AL@@C-V4/ CXONE-AL@@D-V4 CX-Motion-NCF Ver. 1.9 Position Controller Software OPERATION MANUAL CXONE-AL@@C-V4/ CXONE-AL@@D-V4 CX-Motion-NCF Ver. 1.9 Operation Manual Revised
NFC Communication Tray Model: HHX-IT3-Z
INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8
ZEN-SOFT01-V3. Cat.No.W386-E1-03
ZEN-SOFT01-V3 Cat.No.W386-E1-03 ZEN-SOFT01-V3 ZEN Support Software Operation Manual Revised April 2003 iv Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator
1. Preparations Before Updating or Recovering
How to update or recover the system program Ver.8.0 Introduction CDROM includes system program installation program to update or to recover your Programmable Terminal (PT). Please follow the instruction
SoftRAID 5 QUICK START GUIDE. for OWC ThunderBay
SoftRAID 5 QUICK START GUIDE for OWC ThunderBay TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.2 FEATURES 1.3 ABOUT THIS MANUAL SYSTEM SETUP...2 2.1 GETTING STARTED 2.2 INITIALIZING,
RS485 Adapters. User Manual October 26, 2008 V1.02 Copyright Light O Rama, Inc. 2006, 2007, 2008 SC485 USB485B USB485 USB485-ISO
SC485 USB485B USB485 USB485-ISO User Manual October 26, 2008 V1.02 Copyright Light O Rama, Inc. 2006, 2007, 2008 This page intentionally blank Table of Contents Introduction... 4 What s in the Box... 5
USB FLASH DRIVE. User s Manual. USB 2.0 Compliant. Version A10. - 1 - Version A10
USB FLASH DRIVE User s Manual USB 2.0 Compliant Version A10-1 - Version A10 Introduction Thank you for purchasing the USB FLASH DRIVE device. The manual explains how to use the USB FLASH DRIVE software
FINS Gateway For OMRON PLCs
1 Purpose This Technical Note describes how to set up a remote collaboration. A remote collaboration consists in configuring, programming or monitoring a PLC from a remote location, without the need of
WindO/I-NV2 Utility Pass-Through Tool
B-1159(3) WindO/I-NV2 Utility Pass-Through Tool Instruction Manual Introduction This instruction manual explains the operation and handling of the WindO/I-NV2 Utility Pass-Through Tool. Before using the
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
USER S MANUAL. CompoBus/D (DeviceNet) Communications Unit MODEL 3G3MV-PDRT1-SINV. (For SYSDRIVE 3G3MV Multi-function Compact Inverters)
Cat. No. I529-E1-1 USER S MANUAL CompoBus/D (DeviceNet) Communications Unit MODEL 3G3MV-PDRT1-SINV (For SYSDRIVE 3G3MV Multi-function Compact Inverters) Thank you for choosing a 3G3MV Multi-function Compact
UniStream CPU-for-Panel
UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic
NT620S/620C Programmable Terminals OPERATION MANUAL
Cat. No. V033-E1-5 NT620S/620C Programmable Terminals OPERATION MANUAL Authorized Distributor: Cat. No. V033-E1-5 Note: Specifications subject to change without notice. Printed in Japan 0401-0.7M (0597)
Point of view HDMI Smart TV dongle Mini RF Keyboard
Point of view HDMI Smart TV dongle Mini RF Keyboard English Contents Contents... 1 General notices for use... 2 Disclaimer... 2 Box Contents... 2 1. HDMI TV dongle... 3 1.1. Product display... 3 1.2. Instructions
Installation Instructions
Installation Instructions Windows USB driver for Installation If a Diagnostic Interface with USB is connected to a PC with a Windows operating system 98, ME, XP or Vista for the first time, it is necessary
FireWire 800 + Hi-Speed USB Combo Quick Installation Guide
FireWire 800 + Hi-Speed USB Combo Quick Installation Guide Introducing the FireWire 800 + Hi-Speed USB Combo The FireWire 800+Hi-Speed USB Combo features the latest technology in FireWire 800 and USB 2.0.
WE70. FA Wireless LAN Unit. Reliable Wireless Ethernet for Harsh FA Environments Conforms to IEEE 802.11a/b/g
New Product News FA Wireless LAN Unit WE70 Reliable Wireless Ethernet for Harsh FA Environments Conforms to IEEE 802.11a/b/g Construct an Ideal Wireless LAN System for FA Applications! The FA Wireless
USB 2.0 to 10/100Mbps Ethernet Adapter UE-9521. User Manual
USB 2.0 to 10/100Mbps Ethernet Adapter UE-9521 User Manual 1 Copyright Copyright 2004 by PLANET Technology Corp. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
NVIDIA Graphics Card and Driver Installation Guide (Windows NT 4.0 and Windows 2000)
NVIDIA Graphics Card and Driver Installation Guide (Windows NT 4.0 and Windows 2000) Revision 2.1 March 1, 2001 Published by NVIDIA Corporation 3535 Monroe Street Santa Clara, CA 95051 Copyright 2001 NVIDIA
Screen Capture. User s Guide. For ClassPad Series. http://edu.casio.com. http://edu.casio.com/products/classpad/ http://edu.casio.
For ClassPad Series E Screen Capture User s Guide CASIO Education website URL http://edu.casio.com ClassPad website URL http://edu.casio.com/products/classpad/ ClassPad register URL http://edu.casio.com/dl/
LBP-1210 Laser Printer
LBP-1210 Laser Printer Getting Started Guide IMPORTANT: Read this manual carefully before using your printer. Save this manual for future reference. Copyright Copyright 2002 Canon Inc. All information
USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual
USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual 1 Copyright Statement No part of this publication may be reproduced in any form by any means without the prior written permission.
RDC-7 Windows XP Installation Guide
RDC-7 Windows XP Installation Guide CONTENTS 1. End User License Agreement...3 2. Important notes...4 3. Customer support...4 4. Installing the USB driver...4 I. Prior to installation...4 II. Installation
485USBTB-2W & 485USBTB-4W
RS-485 2-Wire RS-485 4-Wire Connector Data Rate Connector Standard Data Rate Source Input Voltage Consumption Driver CD Dimensions Enclosure Weight Operating Temp Storage Temp Op Humidity MTBF MTBF Method
How To Program A Microsoft Cx-One (Microsoft) Microsoft Microsoft Pc (Microsatellite) Microsatellite (Microsimulated) (Microphones) (Powergen) (Programmer) (Cx-
Introduction - Please be sure to read and understand Precautions and Introductions in CX-One Setup Manual, CX-Programmer Operation Manual and CX-Integrator Operation Manual before using the product. -
Config software for D2 systems USER S MANUAL
DT-CONFIG SOFTWARE Config software for D2 systems USER S MANUAL CONTENTS 1. Introductions ------------------------------------------------------------------- 3 2. System Requirement and Connection ----------------------------------------
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
Safety Precautions Read and understand this specifications, instruction manual, installation manual and catalog to make proper use of the product. WARNING If critical situations that could lead to user
2-Port RS232 Serial PCI with 16950 UART Quick Installation Guide
2-Port RS232 Serial PCI with 16950 UART Quick Installation Guide Introduction The 2-Port RS232 Serial PCI with 16950 UART high-speed serial card provides two RS-232 9-pin serial ports. Key Features and
UFR II Driver Guide. UFR II Driver Ver. 2.20 ENG
UFR II Driver Guide UFR II Driver Ver. 2.20 Please read this guide before operating this product. After you finish reading this guide, store it in a safe place for future reference. ENG 0 Ot UFR II Driver
USB to Serial Quick Installation Guide
Introduction USB to Serial Quick Installation Guide The USB to Serial adapter converts one USB port to multiple 9-pin (DB9) serial ports. Features and Benefits Full support for Windows-based software Low
EPSON USB/Parallel Adapter User s Guide
EPSON USB/Parallel Adapter User s Guide EPSON Stylus COLOR 440 EPSON Stylus COLOR 800 EPSON Stylus COLOR 600 EPSON Stylus COLOR 850 EPSON Stylus COLOR 640 EPSON Stylus COLOR 1520 EPSON Stylus Photo EX
EPSON USB/Parallel Adapter User s Guide
EPSON USB/Parallel Adapter User s Guide EPSON Stylus COLOR 440 EPSON Stylus COLOR 1520 EPSON Stylus COLOR 600 EPSON Stylus COLOR 3000 EPSON Stylus COLOR 640 EPSON Stylus Photo 700 EPSON Stylus COLOR 660
Installing the USB driver for Firmware 7 or later For use with E-blocks programmer boards and PICmicro Development boards.
Installing the USB driver for Firmware 7 or later For use with E-blocks programmer boards and PICmicro Development boards. Matrix Multimedia USB PICmicro programmer boards with Firmware version 7 or later
USA MOBILITY CABLE CONNECTION AND SOFTWARE DRIVER INSTALLATION INSTRUCTIONS. For. Unication M90 Device USB To RS232 Adapter TABLE OF CONTENTS
USA MOBILITY CABLE CONNECTION AND SOFTWARE DRIVER INSTALLATION INSTRUCTIONS For Unication M90 Device USB To RS232 Adapter TABLE OF CONTENTS SECTION 1: ADAPTER CABLE CONNECTION INSTRUCTIONS... 2 SECTION
Phase-sequence Phase-loss Relay
New Product Phase-sequence Phase-loss Relay K8DS-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Lineup includes a 17.5-mm slim, compact model. Greater resistance to inverter
NEW PROXIMITY SENSORS E2B
NEW PROXIMITY SENSORS E2B A New World Standard Afforda OMRON, a pioneer in Proximity Sensors, brings you the new E2B Proximity Sensor with exceptional pricing. A complete lineup designed to offer you with
FTP-628WSL-110 Bluetooth Configuration Guide
FTP-628WSL-110 Bluetooth Configuration Guide Configuring the Bluetooth Interface with MS Windows XP Background: The Bluetooth Interface is typically easy to configure, as is the FTP-628 Driver. The mechanics
Handheld LPC Data Retrieval Software for Windows. Operation Manual
Handheld LPC Data Retrieval Software for Windows MODEL S388-70 Operation Manual Read this manual carefully and understand the warnings described in this manual before operating the product. Keep this manual
Installation Instructions for 9555 USB Driver
Prior to using the data modem features of your 9555 handset; you must first install the VCOMPORT 9555 USB Driver. This driver is compatible with: Windows XP Service Pack 2, Windows 2000 Service Pack 4,
Cat. No. V103-E1-02. NV Series NV3W NV4W NV3Q. Programmable Terminals SETUP MANUAL
Cat. No. V103-E1-02 NV Series NV3W NV4W NV3Q Programmable Terminals SETUP MANUAL NV Series NV3W NV4W NV3Q Programmable Terminals Revised December 2009 iv Notice OMRON products are manufactured for use
Cat s Eye USB 3560 HDTV Tuner Installation Guide Version 4.1. VBox Communications Ltd. www.vboxcomm.com
Cat s Eye USB 3560 HDTV Tuner Installation Guide Version 4.1 VBox Communications Ltd. www.vboxcomm.com Copyright 2005, VBox Communications Ltd. All rights reserved. No part of this publication may be reproduced,
Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide
Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide Hypercom Corporation 8888 East Raintree Drive Scottsdale, Arizona 85260 USA Corporate Telephone: 480.642.5000 Corporate
SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM 1 ABOUT THE SOFTWARE. Contents 2 BEFORE INSTALLATION
SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM Page Contents 1 ABOUT THE SOFTWARE BEFORE INSTALLATION INSTALLING THE SOFTWARE 3 CONNECTING TO A COMPUTER 10 CONFIGURING THE PRINTER DRIVER 11 TROUBLESHOOTING
Orbit PCI Mk 2 Network Card. User Manual. Part No. 502566 Issue 4
Orbit PCI Mk 2 Network Card User Manual Part No. 502566 Issue 4 Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless
Kvaser Mini PCI Express User s Guide
Kvaser Mini PCI Express User s Guide Copyright 2013-2014 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Sunday 28 th September, 2014 We believe that the information contained herein was accurate
Chapter 1 Downloading Images to Your Computer (Windows)
Software User Guide For the safe use of your camera, be sure to read the Safety Precautions thoroughly before use. Types of software installed on your computer varies depending on the method of installation
PL-2303 (Chip Rev H, HX, X) USB to Serial Adapter Windows Driver Installer Manual
PL-2303 (Chip Rev H, HX, X) USB to Serial Adapter Windows Driver Installer Manual For Windows 98/ME/2000/XP/Vista/7 Release Version 1.3 (2/4/2010) Contents Introduction Features & Specifications System
Connecting your Omega/BetaPAT PLUS to a PC via a USB
Connecting your Omega/BetaPAT PLUS to a PC via a USB Install software Windows XP and below Insert the disc into your computers disc drive and run through the setup wizard. Windows Vista & 7 1. Insert the
Serial ATA PCI Quick Installation Guide
Serial ATA PCI Quick Installation Guide Introducing the Serial ATA PCI The Serial ATA PCI is an ultra high-speed dual channel Serial ATA controller board for use in Pentium-class computers. It achieves
Welch Allyn Vital Signs Monitor 300 Series
Welch Allyn Vital Signs Monitor 300 Series Upgrade Installation Guide Vital Signs Monitor 300 Series Service Utility Tool Version 2.0.0 ii Welch Allyn Vital Signs Monitor 300 Series Copyright 2007, Welch
SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2
SATA150 TX2PLUS, TX4 QUICK START GUIDE Version 1.2 SATA150 TX2plus, TX4 Copyright 2002 Promise Technology, Inc. Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be
SOFTWARE INSTALLATION AND USB/i.LINK CONNECTION GUIDE
SOFTWARE INSTALLATION AND USB/i.LINK CONNECTION GUIDE ENGLISH LYT1155-001A COPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LTD. M3D8 Printed in Japan 0403-FO-ID-VP This document explains the basic information
NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.
INLINE 5 Software INSTALL BULLETIN Page 2: Installing INLINE 5 Page 6: Removing INLINE 5 NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT. IMPROPER INSTALLATION OR USE CAN
PCI/PXI ETHERNET ADAPTERS
INSTALLATION GUIDE PCI/PXI ETHERNET ADAPTERS Installing Your PCI Board National Instruments offers several Ethernet adapters based on the Intel 82559-compatible Ethernet controller. This document explains
Fiery E100 Color Server. Welcome
Fiery E100 Color Server Welcome 2011 Electronics For Imaging, Inc. The information in this publication is covered under Legal Notices for this product. 45098226 27 June 2011 WELCOME 3 WELCOME This Welcome
Use only a shielded parallel interface cable that is IEEE 1284-compliant and/or a USB cable that is no longer than 6 feet long (1.8 meters).
For Windows XP Users Setting Up the machine and PC to Work Together Before You begin When necessary, please purchase the appropriate interface cable you intend to use with this machine (parallel or USB).
Wireless LAN 802.11g USB Adapter
Wireless LAN 802.11g USB Adapter User s Guide Version 1.0 User s Guide 0 Copyright statement No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
Installation Manual LATC-W1
Installation Manual PRODUCT NAME Controller Setting Software MODEL / Series / Product Number LATC-W1 [Before using this product] Read the "End-User License Agreement" shown on the next page carefully and
SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade
Installation Instructions SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade Catalog Numbers 1747-DU501 Topic Page System Requirements 3 Install ControlFLASH 3 Prior to Running ControlFLASH
Installing the Gerber P2C Plotter USB Driver
Installing the Gerber P2C Plotter USB Driver 1 You can install a Gerber P2C plotter using a USB connection and communicate with it using compatible design software. The following procedures describe installing
USB TO SERIAL CONVERTER
USB TO SERIAL CONVERTER User Manual (DA-70155-1) Index: A. Windows Driver B. MAC Driver C. Linux Driver A. Windows Driver 1. Product Features 2. System Requirements 3. Driver Installation (Win2000) 4.
IMPORTANT! CPD 8424R1
IMPORTANT! You need to reinstall EPSON Image Authentication System (IAS) on your camera if it was installed before your camera was repaired. Please see your EPSON Image Authentication System User s Guide
The UltraATA 133 PCI is an ultra high-speed dual channel Ultra ATA/133 controller board for use in Pentium-class computer.
UltraATA 133 PCI Quick Installation Guide Introducing the UltraATA 133 PCI The UltraATA 133 PCI is an ultra high-speed dual channel Ultra ATA/133 controller board for use in Pentium-class computer. Features
Bluetooth Installation
Overview Why Bluetooth? There were good reasons to use Bluetooth for this application. First, we've had customer requests for a way to locate the computer farther from the firearm, on the other side of
SCADAPack E ISaGRAF 3 User Manual
SCADAPack E ISaGRAF 3 User Manual 2 SCADAPack E ISaGRAF 3 User Manual Table of Contents Part I ISaGRAF 3 User Manual 3 1 Technical... Support 3 2 Safety... Information 4 3 Preface... 6 4 Overview... 8
USB VoIP Phone Adapter. User s Manual
USB VoIP Phone Adapter User s Manual FCC Certifications This Equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 and part 68 of the FCC Rules.
CONTENTS C ONTENTS CONTENTS... 1 SAFETY INSTRUCTIONS... 2 INTRODUCTION... 2 HARDWARE APPEARANCE AND CONNECTIVITY... 4 SETUP INSTRUCTIONS...
C ONTENTS CONTENTS CONTENTS... 1 SAFETY INSTRUCTIONS... 2 INTRODUCTION... 2 HARDWARE APPEARANCE AND CONNECTIVITY... 4 SETUP INSTRUCTIONS... 5 IMPORTANT NOTES:... 19 1 S AFETY I NSTRUCTIONS SAFETY INSTRUCTIONS
Network Interface Panel User s Guide NPD4747-01 EN
User s Guide NPD4747-01 EN Contents Contents Copyright and Trademarks Safety Instructions Important Safety Instructions... 4 Cautions and Notes... 4 Getting to Know Your Network Interface Panel Package
DUKANE Intelligent Assembly Solutions
PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc
Cat. No. W02E-EN-01. SYSMAC CJ-series CJ1W-CTL41-E 4-Channel Counter Unit OPERATION MANUAL
Cat. No. W02E-EN-01 SYSMAC CJ-series CJ1W-CTL41-E 4-Channel Counter Unit OPERATION MANUAL SYSMAC CJ-series CJ1W-CTL41-E 4-Channel Counter Unit Operation Manual Produced September 2004 i ii Notice: OMRON
We reserve the right to make technical changes.
User Guide External Hard Disk with USB 1.1/2.0 and IEEE 1394 connection Copyright 2003 All rights reserved. This manual is protected by Copyright. The Copyright is owned by Medion. Trademarks: MS-DOS and
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
MF652 USB Modem User Guide
MF652 USB Modem User Guide Connection Manager Software Guide... 2 Using your USB Modem... 4 Task bar information... 6 Using the SMS Interface... 7 Using the Phonebook... 9 Phonebook Notes:...10 Settings...11
CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual
Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual
CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual
Instruction Manual Option Card for Frequency Divider Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual and understand the description
WHQL Certification Approval...2 User Interface...3 SUNIX s COMLab..4
INDEX WHQL Certification Approval...2 User Interface....3 SUNIX s COMLab..4 1.0 Introduction...5 2.0 Specification..5 2.1 Features 2.2 Universal Serial PCI Card 2.3 RS-232 Specification 2.4 Low Profile
PN-L702B LCD MONITOR TOUCH PANEL DRIVER OPERATION MANUAL. Version 2.1
PN-L702B LCD MONITOR TOUCH PANEL DRIVER OPERATION MANUAL Version 2.1 Contents Setting up the PC...3 Installing the touch panel driver...3 Touch Panel Settings...4 How to configure settings...4 Calibration...5
Installation Manual. Table of Contents. System Requirements. PC Console Software. Model no. KX-TDA0300
PC Console Software Installation Manual Model no. KX-TDA0300 Thank you for purchasing the Panasonic PC Console Software, KX-TDA0300. Please read this manual before using this product and save for future
USB Security Key Instructions
These instructions describe the Universal Serial Bus (USB) security key used with Interact and InteractX software. For Interact users, the USB security key replaces the obsolete parallel port security
Welch Allyn PCH100 and PCH200 Installation Guide
Welch Allyn PCH100 and PCH200 Installation Guide Copyright 2006-2013 Welch Allyn. All rights are reserved. No one is permitted to reproduce or duplicate, in any form, this manual or any part thereof without
USB Driver Installation for Windows XP
USB Driver Installation for Windows XP USB Serial Converter Driver Installation for Windows XP CAUTION: You must use the drivers on the CD-ROM supplied with your USB Device. DO NOT download drivers from
Blastmate III and Minimate Plus USB to PC Cable (Part No. 716A3401)
Purpose This technical bulletin describes the installation of the Blastmate III and Minimate Plus USB to PC Cable (Part No. 716A3401). Refer to Image A. This cable allows the Blastmate III and Minimate
Data Management Software. CL-S10w. Installation Guide
Data Management Software CL-S10w Installation Guide Safety Warning Please read this manual and the instrument and computer manual carefully beforehand and use the software properly and safely. Official
WHQL Certification Approval...2 User Interface...3 128K software FIFO 4 Universal PCI Interface...5 Ready for 64-bit System...5
0 INDEX WHQL Certification Approval...2 User Interface...3 128K software FIFO 4 Universal PCI Interface...5 Ready for 64-bit System...5 1.0 Introduction 6 2.0 Features.. 6 3.0 Hardware Guide... 7 3.1 System
BMW Multi Tool User Manual
X-Horse Electronics Co., Ltd. Table of Contents 1. Safety Precautions and Warnings... 3 2. General Information... 4 3. Hardware Overview... 5 3.1. Tool Description... 5 3.2. Specifications... 6 3.3. System
DIAL-UP DATA. User s Guide
DIAL-UP DATA User s Guide Iridium Satellite LLC Rev. 5; January 1, 2003 DIAL-UP DATA SERVICE--------------------------------------------------------------------------------------- TABLE OF CONTENTS 1 Dial-Up
LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION
RS-422/485 PCI Card User Manual English No. 51200 (2 Port) No. 51202 (4 Port) No. 51204 (8 Port) www.lindy.com LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION (Nov 2005) 1.0 Introduction
