3 Crestron Contents 1 Introduction...1 Touchpanel Templates... 1 Keypad Templates... 1 QM Devices, IM Devices, and Other Fliptop/Desk Mounted Devices Templates... 2 Touchpanel Mounting Kits and Cutout Dimensions...3 Back Box... 3 Pre-Construction Mounting Kit... 3 Trim Ring... 4 Mud Ring... 4 Rack Mount... 5 Water Resistant Cover Kits... 6 LC-1000, CT-1000 & APAD... 7 TPMC-10-DSW... 8 TPS-12L & TPS-12G-QM-L... 9 TPS-15L, TPS-15G-QM-L, TPMC-15-CH-L & TPMC-15-QM-L TPS-17L, TPMC-17-CH-L, & TPMC-17-QM-L TPS-2000L TPS-3100L TPS-4000L TPS-4500L, TPS-4500LV & TPS-5000L TPS-6000L TPS-4L C2N-FT-TPS STX-1700CW and STX-1700CXPW Thermostats, Temperature and Temperature/Humidity Sensors...22 CHV-TSTAT and CHV-THSTAT CHV-RTS & CHV-RTHS CHV-RSS...23 C2N-RTHS Keypads...25 C2N-CBF MediaManager Devices...26 QM-FTCC, QM-FTDC, QM-FTMC, QM-FTSC, QM-FTMCSC, QMI-FTCC, QMI-FTDC, QMI-FTMC, QMI-FTSC & QMI-FTMCSC QM-FTCC-TPS IM-FTCC-B IM-TCC C2N-FTB Lighting and Shade/Drape Control...30 CAEN Automation Enclosures C2N-SDC and C2N-SDC-DC CLS-C6 and CLS-C6M Further Inquiries...33 Doc. 4926B Contents i
4
5 Crestron Cutout Dimensions & Mounting Options Introduction This document contains the cutout dimensions and mounting options for the current line of wall-mounted/lectern-mounted Crestron devices. Templates are available on the Crestron website and may be ordered as a part number. Refer to the Crestron website: Tools & Resources > Product Resources > Product Cut-Out Templates. NOTE: Crestron cannot guarantee the accuracy of template reproduction on your printer. For precise templates, please order the part number. Touchpanel Templates Model Number Template Part Number TPS-12G-QM-L Template for WMKM-12L/WMKT-12L TPS-15G-QM-L Template for WMKM-15L/WMKT-15L TPMC-10 Template for TPMC-10-DSW TPMC-15-(CH/QM)-L Template for WMKM-15L/WMKT-15L TPMC-17-(CH/QM)-L Template for WMKM-17L/WMKT-17L TPS-12L Template for WMKM-12L/WMKT-12L TPS-15L Template for WMKM-15L/WMKT-15L TPS-17L Template for WMKM-17L/WMKT-17L TPS-2000L Template for WMKM-2000L TPS-3100L Template for WMKM-3000L TPS-4500L Template for direct mounting TPS-5000L TPS-6000L Template for direct mounting TPS-4L Template for direct mounting Template for WMKT-4L C2N-FT-TPS4 Template Keypad Templates Model Number Template Part Number C2N-CBF Template Crestron Doc. 4926B 1
6 Crestron QM Devices, IM Devices, and Other Fliptop/Desk Mounted Devices Templates Model Number Template Part Number QM-FTCC Template QM-FTDC QM-FTMC QM-FTMCSC C2N-FTB QM-FTSC Template QMI-FTCC Template QMI-FTDC QMI-FTMC QMI-FTSC QMI-FTMCSC QM-FTCC-TPS4 Template C2N-FT-TPS4 QMI-FTCC-TPS4 Template IM-FTCC-B Template Crestron Doc. 4926B
7 Crestron Touchpanel Mounting Kits and Cutout Dimensions Back Box Crestron offers a number of optional kits for mounting touchpanels. The Back Box is used in a pre-construction environment, before the drywall is installed. It attaches to a stud and provides a very secure mounting. Pre-Construction Mounting Kit The Pre-Construction Mounting Kit provides a quick nail-in solution for installing wall mount touchpanels and permits fastening to the stud of a framed wall prior to hanging drywall. Crestron Doc. 4926B 3
8 Crestron Trim Ring The Trim Ring is an optional accessory for use with the preconstruction wall mounting kit and back box to provide a smooth edge around the opening and compensate for minor drywall cutout imperfections. Examples of Post Construction Wall Mount Kit with Trim Ring. Mud Ring The Mud Ring is an optional accessory used to compensate for significant drywall cutout imperfections by providing a suitable surface for the application of plaster for a finished appearance. Examples of Post Construction Wall Mount Kit with Mud Ring. 4 Crestron Doc. 4926B
9 Crestron Rack Mount The Rack Mount is an optional mounting accessory that allows for the installation of a touchpanel in a 19-inch EIA equipment rack. RMK-12L RMK-15L RMK-17L RMK-3100L RMK-4000L Model Height Occupied Rack Spaces RMK-12L inches (35.49 cm) Eight rack spaces RMK-15L inches (39.93 cm) Nine rack spaces RMK-17L inches (39.93 cm) Nine rack spaces RMK-3100L 8.72 inches (22.15 cm) Five rack spaces RMK-4000L inches (26.59 cm) Six rack spaces Crestron Doc. 4926B 5
10 Crestron Water Resistant Cover Kits The Water Resistant Cover Kit protects touchpanels wherever they may be exposed to moisture or dampness such as basements, pools, boathouses, bathrooms, laundries and garages. The urethane covers install easily over the faceplate of the touchpanel. Without hindering normal use, they effectively prevent liquids and other airborne materials from settling onto the face of the panel. CT/LC-WPK Water Resistant Cover for CT-1000 and LC-1000 TPS-WPK Water Resistant Cover for TPS-2000 NOTE: Please note that Crestron touchpanels are not intended to be exposed to the elements or used under conditions exceeding the environmental limits of 50 to 113 F (10 to 45 C), 10% to 90% RH (non-condensing). 6 Crestron Doc. 4926B
11 Crestron LC-1000, CT-1000 & APAD Pre-Construction Mounting Options for the LC-1000, CT-1000 & APAD Touchpanels PRE-CONSTRUCTION KITS Back Box Kit Pre-Construction Kit Mud Mount Kit Trim Mount Kit BB-1000L PMK-1000L MMK-1000L TMK-1000L Post-Construction Mounting Options for the LC-1000, CT-1000 & APAD Touchpanels POST-CONSTRUCTION KITS Wall Mount Mud Kit Wall Mount Trim Kit Water Resistant Cover WMKM-1000L WMKT-1000L CT/CL-WPK NOTE: Early production units ship with two mounting brackets (and other parts) that allowed the low-voltage touchpanel to be installed directly into a mounting surface. Cutout for Trim Ring Mount Kits: TMK-1000L & WMKT-1000L Back Box Dimensions for BB-1000L NOTE: For additional mounting information, refer to the latest version of the Crestron Touchpanel Mounting Quick Start, Doc. 6140, available from the Crestron website ( Crestron Doc. 4926B 7
12 Crestron TPMC-10-DSW The TPMC-10-DSW is a wall-mounted docking station for the Crestron TPMC-10 Isys i/o WiFi Touchpanel. The TPMC-10-DSW, recessed in the wall, turns the TPMC-10 into a fully-functioning wall mounted touchpanel, and charges its built-in battery at the same time. Cutout for TPMC-10-DSW NOTE: For additional details, refer to the latest version of the TPMC-10-DSW Operations and Installation Guide (Doc. 6400), available from the Crestron website. 8 Crestron Doc. 4926B
13 Crestron TPS-12L & TPS-12G-QM-L Pre-Construction Mounting Options for the TPS-12L & TPS-12G-QM-L Touchpanels PRE-CONSTRUCTION KITS Back Box Kit Pre-Construction Kit Mud Mount Kit Trim Mount Kit BB-12L PMK-12L MMK-12L TMK-12L Post-Construction Mounting Options for the TPS-12L & TPS-12G-QM-L Touchpanels POST-CONSTRUCTION KITS Wall Mount Mud Kit Wall/Lectern Mount Trim Kit Rack-Mount Kit WMKM-12L WMKT-12L RMK-12L TPS-12L & TPS-12G-QM-L Cutout Dimensions Back Box BB-12L Dimensions Crestron Doc. 4926B 9
14 Crestron TPS-15L, TPS-15G-QM-L, TPMC-15-CH-L & TPMC-15-QM-L Pre-Construction Mounting Options for the TPS-15 and TPS-15G-QM-L Touchpanels PRE-CONSTRUCTION KITS Back Box Kit Pre-Construction Kit Mud Mount Kit Trim Mount Kit BB-15L PMK-15L MMK-15L TMK-15L Post-Construction Mounting Options for the TPS-15 and TPS-15G-QM-L Touchpanels POST-CONSTRUCTION KITS Wall/Lectern Mount Trim Kit Wall Mount Kit with Mud Ring Rack-Mount Kit WMKT-15L WMKM-15L RMK-15L TPS-15L, TPS-15G-QM-L, TPMC-15-CH-L & TPMC-15-QM-L Cutout Dimensions Back Box BB-15L Dimensions 10 Crestron Doc. 4926B
15 Crestron TPS-17L, TPMC-17-CH-L, & TPMC-17-QM-L Pre-Construction Mounting Options for the TPS-17L Touchpanels PRE-CONSTRUCTION KITS Back Box Kit Pre-Construction Kit Mud Mount Kit Trim Mount Kit BB-17L PMK-17L MMK-17L TMK-17L Post-Construction Mounting Options for the TPS-17L Touchpanels POST-CONSTRUCTION KITS Wall/Lectern Mount Trim Kit Rack-Mount Kit WMKT-17L RMK-17L TPS-17L, TPMC-17-CH-L, & TPMC-17-QM-L Cutout Dimensions Back Box BB-17L Dimensions Crestron Doc. 4926B 11
16 Crestron TPS-2000L Pre-Construction Mounting Options for the TPS-2000L Touchpanels PRE-CONSTRUCTION KITS Back Box Kit Pre-Construction Kit Mud Mount Kit Trim Mount Kit BB-2000L PMK-2000L MMK-2000L TMK-2000L Post-Construction Mounting Options for the TPS-2000L Touchpanels POST-CONSTRUCTION KITS Wall Mount Mud Kit Wall Mount Trim Kit Water Resistant Cover WMKM-2000L WMKT-2000L TPS-WPK TPS-2000L Cutout Dimensions NOTE: For additional TPS-2000L mounting information, refer to the latest version of the Crestron Touchpanel Mounting Quick Start, Doc. 6140, available from the Crestron website ( Back Box BB-2000L and Mounting Plate Dimensions 12 Crestron Doc. 4926B
17 Crestron TPS-3100L Pre-Construction Mounting Options for the TPS-3100L Touchpanels PRE-CONSTRUCTION KITS Back Box Kit Pre-Construction Kit Mud Ring Only Trim Ring Only BB-3100L PMK-3100L MMK-3100L TMK-3100L Post-Construction Mounting Options for the TPS-3100L Touchpanels POST-CONSTRUCTION KITS Wall/Lectern Mount Kit with Trim Ring Wall Mount Kit with Mud Ring Architectural Faceplates Rack Mount Kit WMKT-3100L WMKM-3100L TPS-FPAR3100L RMK-3100L TPS-3100 Cutout Dimensions Back Box BB-3100L Dimensions WARNING: The TPS-3100L is physically different from the discontinued TPS-3000L and the mounting options and cutout dimensions are not interchangeable. NOTE: For additional TPS-3100 mounting information, refer to the latest version of the Crestron Touchpanel Mounting Quick Start, Doc. 6140, available from the Crestron website ( Crestron Doc. 4926B 13
18 Crestron TPS-4000L Pre-Construction Mounting Options for the TPS-4000L Touchpanels PRE-CONSTRUCTION KITS Back Box Kit Pre-Construction Kit Mud Ring Only Trim Ring Only BB-4000L PMK-4000L MMK-4000L TMK-4000L Post-Construction Mounting Options for the TPS-4000L Touchpanels POST-CONSTRUCTION KITS Wall/Lectern Mount Kit with Trim Ring Wall Mount Kit with Mud Ring Architectural Faceplates Rack Mount Kit WMKT-4000L WMKM-4000L TPS-FPAR4000L RMK-4000L TPS-4000L Cutout Dimensions NOTE: For additional TPS-4000L mounting information, refer to the latest version of the Crestron Touchpanel Mounting Quick Start, Doc. 6140, available from the Crestron website ( Back Box BB-4000L Dimensions 14 Crestron Doc. 4926B
19 Crestron TPS-4500L, TPS-4500LV & TPS-5000L Pre-Construction Mounting Options for the TPS-4500L, TPS-4500LV, & TPS-5000L Touchpanels PRE-CONSTRUCTION KITS Back Box Kit BB-5000L Post-Construction Mounting Options for the TPS-4500L, TPS-4500LV, & TPS-5000L Touchpanels POST-CONSTRUCTION KITS Architectural Faceplates Rack Mount Kit TPS-FPAR5000L RMK-5000L TPS-4500L, TPS-4500LV & TPS-5000L Cutout Dimensions HORIZONTAL MEASUREMENTS VERTICAL MEASUREMENTS RADIUS MEASUREMENTS H1 = in ( cm) V1 = in ( cm) R1 =0.161 in (0.409 cm) typical H2 =1.056 in (2.682 cm) V2 = in ( cm) R2 =0.312 in (0.792 cm) typical H3 = in ( cm) V3 =9.866 in ( cm) H4 =2.054 in (5.217 cm) V4 =0.179 in (0.455 cm) H5 =8.953 in ( cm) V5 =0.089 in (0.226 cm) H6 =4.305 in ( cm) H7 =4.452 in ( cm) H8 =5.282 in ( cm) H9 =2.500 in (6.350 cm) Crestron Doc. 4926B 15
20 Crestron Back Box BB-5000 Dimensions 16 Crestron Doc. 4926B
21 Crestron TPS-6000L Pre-Construction Mounting Options for the TPS-6000L Touchpanels PRE-CONSTRUCTION KITS Back Box Kit BB-6000L Post-Construction Mounting Options for the TPS-6000L Touchpanels POST-CONSTRUCTION KITS Architectural Faceplates Rack Mount Kit TPS-FPAR6000L RMK-6000L BB-6000 Cutout Dimensions Crestron Doc. 4926B 17
22 Crestron Back Box BB-6000L Dimensions 18 Crestron Doc. 4926B
23 Crestron TPS-4L Pre-Construction Mounting Options for the TPS-4L Touchpanels PRE-CONSTRUCTION KITS Back Box Kit Wall Mount Kit Trim Ring Mud Ring BB-4L PMK-4L TMK-4L MMK-4L Post-Construction Mounting Options for the TPS-4L Touchpanels POST-CONSTRUCTION KITS Lectern/Wall Mounting Kit with Trim Ring Wall Mount Kit with Mud Ring WMKT-4L WMKM-4L TPS-4L Pre Construction Cutout Template Dimensions TPS-4L Post Construction Cutout Template Dimensions Crestron Doc. 4926B 19
24 Crestron C2N-FT-TPS4 20 Crestron Doc. 4926B
25 Crestron STX-1700CW and STX-1700CXPW Optional Mounting Devices DA-1700CW BB-1700CW Back Box Docking assembly, attaches to back box Back box for wall mounting Back Box Enclosure BB-1700CW Physical Views and Dimensions Crestron Doc. 4926B 21
26 Crestron Thermostats, Temperature and Temperature/Humidity Sensors CHV-TSTAT and CHV-THSTAT Thermostats are mounted to a single-gang electrical box, or directly to the wall using hollow wall anchors. 22 Crestron Doc. 4926B
27 Crestron CHV-RTS & CHV-RTHS CHV-RSS Crestron recommends that the sensor be placed inside a ½ inch Electrical Metallic Tubing (EMT) conduit. This allows future sensor replacement, if required. The radius of the bend at the wall should be approximately eight inches, to allow for removal and replacement of the sensor. Sensor Position Side View Crestron Doc. 4926B 23
28 Crestron CHV-RSS Tile Floor Mounting CHV-RSS Wood Floor Mounting C2N-RTHS NOTE: The C2N-RTHS is not to be used in conjunction with the CHV-TSTAT or the CHV-THSTAT. The C2N-RTHS is a Cresnet network device. 24 Crestron Doc. 4926B
29 Crestron Keypads C2N-CBF The following figure illustrates the supplied template used to prepare the hole in the wall or other mounting surface for the flush mounting style Cameo keypad. NOTE: Use only the original template, not a photocopy, to prepare the hole. Photocopies usually alter the size of the image slightly, which would make the hole the wrong size. Be careful when cutting the hole, the spring clips on the keypad does not have provision for positioning adjustment. Also, ensure that there is a sufficient clearance area behind the mounting surface as shown on the template. Crestron Doc. 4926B 25
30 Crestron MediaManager Devices QM-FTCC, QM-FTDC, QM-FTMC, QM-FTSC, QM-FTMCSC, QMI-FTCC, QMI-FTDC, QMI-FTMC, QMI-FTSC & QMI-FTMCSC The QM domestic and QMI international Fliptops are designed to mount in a horizontal surface, such as a desk top, lectern, or podium. The following diagram illustrates the required opening size to accommodate the QM Fliptop. A cutout template ( or ) is included. Cutout Dimensions QM ( ) QMI ( ) NOTE: Before inserting the QM-FTCC in the mounting hole, ensure that all required cables have been installed. QM-FTCC-TPS4 26 Crestron Doc. 4926B
31 Crestron QM-WMC and QM-WMIC NOTE: The QM-WMIC can be installed when the QM-WMC is being installed or after the QM-WMC has been installed. If the QM-WMIC is to be installed into an existing QM-WMC installation, all electronic connections to the QM-WMC should be removed prior to removing the QM-WMC from its two-gang electrical wallbox. A three-gang box must replace the two-gang electrical wallbox. IM-FTCC-B The IM-FTCC-B is designed to mount in a horizontal surface, such as a desk top, lectern, or podium. The following diagram illustrates the required opening size to accommodate the IM-FTCC-B. Use the supplied template to make the cutout. Cutout Dimensions NOTE: Before inserting the IM-FTCC-B in the mounting hole, ensure that all required cables have been installed. Crestron Doc. 4926B 27
32 Crestron IM-TCC The IM-TCC is designed to mount to the underside of a horizontal surface, such as a desktop, lectern, or podium, in a cutout area. Bracket Dimensions Cutout Dimensions Cutaway View of Mounting 28 Crestron Doc. 4926B
33 Crestron C2N-FTB The C2N-FTB-B and the C2N-FTB-BALUM are Crestron keypad devices that provide a stylish flush-mount tabletop interface and control solution. The fliptop compartment provides organized storage for a variety of pullout computer, communication, and A/V cables, which stow neatly out of sight within the fliptop compartment when not in use. The keypad provides A/V, lighting, and other functional controls via Cresnet. Cutout Dimensions Crestron Doc. 4926B 29
34 Crestron Lighting and Shade/Drape Control CAEN Automation Enclosures CAUTION: These enclosures house equipment that needs to be air-cooled. Therefore, mount in a well-ventilated area. The ambient temperature range should be 32 F to 104 F (0 C to 40 C). The relative humidity should range from 0% to 90% (non-condensing). Furthermore, allow adequate clearance in front of the vented cover for servicing and ventilation. NOTE: Enclosures are intended for indoor use only. NOTE: When flush mounting, 5/8 drywall is preferred. NOTE: Four keyholes are located within the enclosure and should be used if surface mounting. CAEN-Series enclosures are required to install CLX-Series lighting modules. All measurements of length are in inches and weight is in pounds. The lower keyholes are not symmetrically spaced within single-wide enclosures. Weight (empty) is the weight of an empty enclosure with cover. Weight (filled) is the weight with the maximum number of modules installed. 30 Crestron Doc. 4926B
35 Crestron C2N-SDC and C2N-SDC-DC The C2N-SDC and C2N-SDC-DC may be mounted in a two-gang electrical box or a 4 x 4 (1900) electrical box. Ensure that you are using a box with sufficient depth (minimum 1 ½ ) to accommodate the wires and connectors required. Crestron Doc. 4926B 31
36 Crestron CLS-C6 and CLS-C6M The CLS-C6 and CLS-C6M mount in a standard 4-gang electrical box. 32 Crestron Doc. 4926B
37 Crestron Further Inquiries If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling the Crestron corporate headquarters at CRESTRON [ ]. For assistance in your local time zone, refer to the Crestron website ( for a listing of Crestron worldwide offices. You can also log onto the online help section of the Crestron website to ask questions about Crestron products. First-time users will need to establish a user account to fully benefit from all available features. Crestron Doc. 4926B 33
38 Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ Doc. 4926B Tel: 888.CRESTRON Fax: Specifications subject to change without notice.
Crestron TMK-6L & WMKT-6L Trim Ring Mount Kits Installation Guide
Crestron TMK-6L & WMKT-6L Trim Ring Mount Kits Installation Guide This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh,
CAEN Automation Enclosures
> > Enclosures for CLX Series lighting control modules, the CLX-DIN-AP3 3-Series Control System, and the PAC2M automation control system > > Available in six convenient sizes > > Surface or flush wall-mountable
Cable Cubby 1200 and 1400 Installation Guide
e NT: R.com for thtion O P IM tron talla w.ex uide, ins ations. o ww Go t te user g specific nd ple com ctions, a u instr 00 and 400 Installation Guide This guide provides instructions for an experienced
About the BitStorm 6051 POTS Splitter
BitStorm 6051 Installation Instructions Document Number 6051-A2-GZ40-10 July 2002 About the BitStorm 6051 The BitStorm system enables simultaneous high-speed digital data access and analog voice service
Selection Chart T-4000 Series Accessories (Part 1 of 5) Code Number Figure Description Application (High or Low Volume)
Code No. LIT-1921710 Issued July 25, 2011 T-4000 Series Accessories Selection Chart T-4000 Series Accessories (Part 1 of 5) ( or Volume) F-100-20 F-300-30 F-300-34 F-300-31 F-300-35 F-500-45 F-300-30 Coupler,
AT&T. PARTNER Plus Door Phone. Installation and Operation Manual
AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
Installation Guide. DEVIreg 530. Electronic Thermostat. www.devi.com
Installation Guide DEVIreg 530 Electronic Thermostat www.devi.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive
WIRELESS STATUS MONITOR
INSTALLATION INSTRUCTIONS WIRELESS STATUS MONITOR (WSM or AUWSM) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-032-D Schlage 245 W. Roosevelt Road,
AutoDome Easy II. VEZ Series. Mounting Manual
AutoDome Easy II VEZ Series en Mounting Manual AutoDome Easy II Table of Contents en 3 Table of Contents 1 Important Safety Instructions 5 2 Unpacking 7 2.1 Parts List 7 3 Description 9 4 Installing a
AMF112 Instruction Manual
AMF112 Instruction Manual Scan here to view product demo and install videos or visit san.us/103 Milestone AV Technologies 6436 City West Parkway Eden Prairie, MN 55344 USA Customer Service Americas: 800-359-5520
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
ilux Lighting Systems
Introduction Features and Functions ilux Systems The ilux units, CLS-C6 and CLS-C6M, are complete integrated wall-mounted lighting systems that can function as standalone devices or be part of a total
AMF112 (6904-002010 <00>) 13mm (1/2 in.)
AMF112 () Concrete Wood 13mm (1/2 in.) 5.5mm (7/32 in.) 10mm (3/8 in.) Sanus Systems 2221 Hwy 36 West Saint Paul, MN 55113 USA Customer Service Americas: 800-359-5520 651-484-7988 [email protected] Europe,
Guidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
DCF Optimized Rack System
Integrated Cabinet Solutions For Business-Critical Continuity DCF Optimized Rack System User Manual IMPORTANT SAFETY GUIDELINES SAVE THESE INSTRUCTIONS This manual contains important instructions that
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
Remote Power Panels with Breakers
Remote Power Panels with Breakers 8 Series Panels & Enclosures N/A N/A Remote power panels with breakers are available in two different sizes, each of which may be either surfacemounted or recess-mounted,
Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors
Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
DE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
GLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS- - - - - - SpaceBuild Specification Worksheet. Touch Screens
SpaceBuild Specification Worksheet GLPHASE System The GLPHASE SpaceBuilder system is ideal for medium-sized spaces that require additional options such as expansion modules for more load types, touch screens,
Senses SV series industrial monitor user manual
Industrial Monitors Senses SV series Senses SV19 / SV17 User manual (Issue A) Part No: 85090084 Page 1 of 25 Copyright Copyright 2008 Amplicon Liveline Ltd. All rights reserved. This publication, including
Seismic Installation for Attic Storage System
Your Performance Partner Seismic Installation for Storage System CONTENTS SSafety Precautions................................. 2 Required Tools..................................... 2 Parts and Fastener
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
Basic Spring Motor Roller Shades
Comprehensive Roller Shade Installation Guide Basic Spring Motor Roller Shades ATTENTION!!! READ CAREFULLY! This shade has a reliable long-lasting Spring Motor. The Spring Motor must have proper tension
Rack Cabinets. Rack Configuration. 19 inch
Rack Cabinets Rack Configuration 19 inch 19 RACK COMPONENTS FEATURES Hallam Manufacturing s range of 19 inch racks and cabinets for today s data/communications installations are designed and manufactured
Hollow or Cinder Block Wall Mount Job Aid
Summary This Job Aid covers: Hollow or Cinder Block Wall Mount Job Aid Hollow or Cinder Block wall Mount Bracket Installing the Mount Bracket into Cinder Block This Job Aid supports the Technician audience.
Installation Instructions
READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
Cisco Unmanaged Rackmount Switches
Quick Start Guide Cisco Small Business Cisco Unmanaged Rackmount Switches Package Contents Cisco SF 100-16, SF 100-24, SF 102-24, SG 100-16, SG 100-24, or SG 102-24 Unmanaged Rackmount Switch Rackmount
Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide
Lunette 2 Series Curved Fixed Frame Projection Screen User s Guide Important Safety and Warning Precautions Please follow these instructions carefully to ensure proper maintenance and safety with your
QFP910. Water detector. Building Technologies. CE1N2732en 2016-03-01. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
Beadboard Wall Bookcase
Beadboard Wall Bookcase Note: The maximum load for each shelf is 30lbs.This hanging system is meant for drywall/wood stud mounting only. If walls are concrete, brick or plaster, please consult your local
Wren Kitchens Installation Tips... 3. Carefully check your kitchen delivery... 4. Measuring out and marking up... 5. Fitting the base cabinets...
tra 1 Index Wren Kitchens Installation Tips... 3 Carefully check your kitchen delivery... 4 Measuring out and marking up... 5 Fitting the base cabinets... 6 Fitting the corner cabinets... 7 The 972mm or
electrics P OW E R E N T RY B A S I C S P OW E R & C O M M U N I C AT I O N S B A S I C S P OW E R D I S T R I B U T I O N B A S I C S
P RO D U C T M A P / TA B L E O F C O N T E N T S..................6 8 6 E L E C T R I C S & C O M M U N I C AT I O N S O V E RV I E W.............6 8 9 P OW E R E N T RY B A S I C S PA N E L - M O U N
Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales
Installation information METTLER TOLEDO MultiRange Floor scales / Pit scales KC300/KCS300 KC600/KCS600 KD600/KD1500 KE1500/KE3000 KES1500/KES3000 KG3000/KG6000 KN1500 Floor scales / Pit scales Contents
Guidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
ColorDial Pro Easily configure and control LED light shows
Easily configure and control LED light shows Easily configure and control LED light shows is an Ethernet-based, stand-alone lighting controller and interface for intelligent RGB and intelligent white (iw)
4RU High Density Shelf Installation Instructions
4RU High Density Shelf Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Tools Required... 3.0 Package Contents... 4.0 Installing the Product Unpacking...
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
Unpacking, Installation, and Customization
Unpacking, Installation, and Customization NetShelter WX Enclosure AR100 AR100HD Contents Unpacking... 1 How to Unpack the Enclosure............................... 1 Please Recycle..........................................
Crestron Green Light Residential Lighting Design Guide
Crestron Green Light Residential Lighting Design Guide 2009 Crestron Electronics Inc. 15 Volvo Drive Rockleigh, NJ 07647 800.237.2041 www.crestron.com For Commercial Lighting Solutions, refer to Doc.
Architect/Contractor Information Package
Architect/Contractor Information Package 3M SelfCheck System C-Series C1 Model 877 This package provides architects and contractors with the information necessary for the successful installation of the
Dell E Series Monitor VESA Mounting Bracket Installation Instructions
Dell E Series Monitor VESA Mounting Bracket Installation Instructions The VESA mounting bracket enables a Wyse cloud client to be mounted to the Dell E Series Monitor. The bracket attaches to the monitor
WHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST
0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL
Crestron Intercom Systems
Description This document provides details of the intercom and paging systems that are available from Crestron. All solutions are fully integrated using a Crestron control system. Feature Comparison Features
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual This 30Amp charge controller is designed to protect your 12Volt Lead-acid or Gel-cell battery from being overcharge by solar
LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels
369344c 04.28.204 LP dimming panels are ideal for projects with many small loads. Each panel provides power and dimming for up to 32 dimming legs. Features Works directly with incandescent, magnetic low
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133
INSTALLATION AND SERVICE MANUAL
CI8100 IMI Wilshire, Inc. IMI WILSHIRE, INC. COUNTER INTELLIGENCE BEVERAGE SYSTEM CI8100 INSTALLATION AND SERVICE MANUAL 1993 IMI Wilshire, Inc. TABLE OF CONTENTS CI8100 IMI Wilshire, Inc. SECTION I CI8100
INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast
PS6500 Storage Arrays Rack Mount Instructions
PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks
Laboratory Construction Guidelines Vicon MX Systems
Laboratory Construction Guidelines Vicon MX Systems These Vicon MX Laboratory Construction Guidelines illustrate how to prepare a life sciences laboratory for installation of your new Vicon MX motion measurement
MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION
MACHINEMATE CNC SYSTEM Hardware SPECIFICATION Feb 2005 CONTENTS 1 Introduction / General... 3 1.1 Superior Capability in Technology and Productivity... 3 1.2 General hardware components... 4 1.3 Static
Batibox TM flush-mounting boxes for dry partitions
flush-mounting boxes for dry partitions 800 51 800 42 800 53 800 54 800 42 + 800 71 800 77 Cat.Nos 1-gang boxes For 1 module 20 800 40 Drilling diameter 32 mm Depth 40 mm For 1 gang or 2 modules For wiring
Flush-mount room temperature sensor AQR2531ANW.
1 408 Flush-mount room temperature sensor AQR2531... Passive sensor to acquire room temperature. Field of use 0 +50 C Use In heating, ventilation and air conditioning plants, primarily in the comfort range
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
installation guide ACTIV-1
installation guide ACTIV- Base foot. Leg x columns - right & left Motor unit. Work surface supporting bracket (Cantilever) x Control. box Base foot x Handset 4. Phase Motor unit Materials and Tools Hardware
Installation Guide. Bath and Wall Surrounds SERIES 7104 1021861-2-B
Installation Guide and Wall Surrounds SERIES 7104 1021861-2-B Thank You For Choosing Sterling We appreciate your commitment to Sterling value. Please take a few minutes to review this manual before you
Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery
Alpha System ADAPTABLE LABORATORY FURNITURE KEWAUNEE encouraging new discovery Alpha 6 partition modules with Kemresin worktops. Minneapolis, Minnesota Alpha 6 partition modules with Alpha overhead service
Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V
Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................
Steel Door Frame Installation in Steel Stud Construction
Steel Door Frame Installation in Steel Stud Construction For use with the Steel Door Institute (SDI) video How to Install a Steel Door Frames in Steel Stud Construction This manual gives you step-by-step
glass & Glazing Products
glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system
HOW TO MEASURE FOR DRAPERY & WINDOW
HOW TO MEASURE FOR DRAPERY & WINDOW From the fabric you select to the hardware that you choose, window treatments are an opportunity to define a room s style. This guide outlines the various drapery styles
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
CELO5. User & Installation Manual. www.audac.eu
CELO5 User & Installation Manual www.audac.eu 2 Introduction 5 High-end Slim Ceiling Speaker The CELO5 is the 5 version of AUDAC s CELO High-end Slim ceiling speaker series with an RMS power of 50 Watt
UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video
UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video http://bit.ly/9ywwh! CAUTION MAKE SURE NO OBSTACLES ARE IN THE DESK S PATH AND ALL
Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN
Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN Installation Instructions Structural Information For standard systems and most custom single door opening systems. General Overview
HVAC Vents & Diffusers
2 HVAC Vents & Diffusers Drywall, Stone, & Wood Applications TRUFIG can be installed in a variety of finishes and surfaces. This guide will detail the install of HVAC vents and diffusers in drywall, stone,
NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures
NEW RANGE OF CABINETS DRIVIATM Innovation at your service THE GLOBAL SPECIALIST in electrical and digital building infrastructures Drivia true innovation The new electrical panel for the residential and
Sliding Door Hardware Installation Instructions
Sliding Door Hardware Installation Instructions Installation Instructions Structural Information For standard systems and most custom single door opening systems. General Overview ff All Krown Lab sliding
SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide
Introduction This guide is to assist the reader with the most basic form of installation and connection to switches in this series. As there is more than one switch in this series, the diagrams might slightly
RK-1 RK-10 RK-13 RK-4X. RK-701xl MOUNTING & RACK ADAPTERS
RK-1 19-inch rack adapter for mounting multiple desktop and/or MultiTOOLS models into a 1U RK-10 19-inch rack adapter for mounting 1 desktop model into a 1U RK-13 19-inch rack adapter for mounting 3 one-third
Installation Instructions
Installation Instructions For Use with PXPV230, PXPV265, PXPD230, and PXPD265 models Attention! - Please read these instructions completely before attempting installation. Always unplug the power supply
Installing Your 960 or 980 Server into a Rackmount Cabinet
Installing Your 960 or 980 Server into a Rackmount Cabinet 1 2 Contents Installing Your Gateway Server into a Rackmount Cabinet...1 Identifyingpartsintheaccessorykit...2 Rackmounthandlekit... 2 Rackmountrailkit...
PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE
MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE OPERATING MANUAL HAA51 PASSIVE INFRARED INTRUDER DETECTOR INTRODUCTION HAA51 Passive Infrared
INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS
BATH SINKS INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Caution: All installation types need to allow room for faucet installation. Ensure adequate clearance behind the basin for your faucet and
Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to 1.22 1.11
Knürr Miracel 19 Network and Server Rack Platform 1.12 to 1.22 1.11 19" Server Rack: Knürr Miracel Strong points 1.13 Knürr Miracel ASP ASP/Server Rack 1.16 Knürr Miracel Server Rack 1.18 Knürr Miracel
Installation instructions, accessories. Cruise control. Volvo Car Corporation Gothenburg, Sweden. Instruction No Version Part. No. 30739998 1.
Instruction No Version Part. No. 30739998 1.1 Cruise control Page 1 / 11 Equipment A0000162 A0000161 A0801178 D8802049 Page 2 / 11 M8802108 Page 3 / 11 IMG-223164 Page 4 / 11 IMG-213320 Page 5 / 11 INTRODUCTION
19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.
19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile
Rack Installation Instructions
Rack Installation Instructions Guidelines This publication provides information about how to install your server into a standard rack cabinet using the rail kit shipped with your server. If you no longer
Complete units. Complete underfloor box for one Modul 45 socket and two data connection sockets. Complete service outlets
Complete underfloor box for one Modul 45 socket and two data connection sockets Screed height 105-165 mm In the field of complete service outlets, the GE 1 and GET 1 models are a universal, high-quality
Models HD920EV HD930EV LW5000EV WD962KEV WD962KPEV WD962MLEV 349544
.. Belt Drive Battery Backup Garage Door Opener Models HD920EV HD930EV LW5000EV WD962KEV WD962KPEV WD962MLEV 349544 FOR RESIDENTIAL USE ONLY Please read this manual and the enclosed safety materials carefully!
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
MGB Chrome Bumper Conversion
MGB Chrome Bumper Conversion Installation Instructions For 1974 1/2-1980 MGB This kit requires cutting, welding, and painting. Professional installation recommended. Note: Every MGB body is slightly different
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
Models HD920EV HD930EV LW5000EV WD962KEV WD962KPEV WD962MLEV 349544
.. Belt Drive Battery Backup Garage Door Opener Models HD920EV HD930EV LW5000EV WD962KEV WD962KPEV WD962MLEV 349544 FOR RESIDENTIAL USE ONLY Please read this manual and the enclosed safety materials carefully!
Rack Installation Instructions
Rack Installation Instructions Second Edition (June 2014) 2014 Contents Chapter 1. Safety information..... 1 Chapter 2. Rack kit parts inentory... 3 Chapter 3. Rack installation...... 5 Identifying the
Panel Track Installation Guide
Panel Track Installation Guide We make it easy! BTG 493361 EN_0510 Before starting Your new Blinds To Go panel track is custom made to your specifications from the finest materials available. To ensure
PUBLIC RESTROOMS, DESIGN INTENT
PUBLIC RESTROOMS, DESIGN INTENT 1.01 STRUCTURAL A. Where feasible, metal stud partitions will be constructed on a 6 high concrete curb. 1.02 MECHANICAL A. Restrooms will have a minimum of 15 air changes
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: