Insulá. Thermally Broke Bolt on Balcony Systems
|
|
|
- Brian Gallagher
- 9 years ago
- Views:
Transcription
1 Insulá Thermally Broke Bolt on Balcony Systems
2 Introduction Balcony Types EuroKobra Design Regulations What is a bolt on balcony? How does it work? Where can it be used? What types of balcony do you supply? What makes the bolt on balcony system different? Drainage System Testing thermal performance Thermal imaging Inset or recessed. Balustrading Balcony chassis Chassis metalwork What regulations are there regarding balustrading? Balustrading regulation BS 6399 Protection from falling. Anchor Points Undertrays
3 THERMALLY BROKEN BOLT ON BALCONY SYSTEMS Connection Detail Connection Detail Connection Detail Connection Detail Advantages What construction types can a bolt on balcony be used in? Wind Post Cast in situ Timber frame Eco-Joist Summary Pre-cast concrete Wooden Floor Joist
4 2 Thermally Broken Bolt on Balconies Introduction What is a thermally broken bolt on balcony? Introduction Regardless of who you are, where you live or what you do, the world is going green like never before and everyone has a part to play. With such a need to reduce the amount of energy that we are using, there has never been more emphasis placed on conserving the amount of fuel and power used within buildings then there is now. Insulá are world leaders in the design and manufacture of bespoke metal work, specialising in ThermConX thermal break connections and thermally brocken bolt on balcony systems. Insulá are proud to introduce the first ever range of thermally broken bolt on balconies designed specifically to be manufactured to specification off site and then attached to the building at a later date in the build schedule, when all of the scaffolding has been removed. What is a thermally broken bolt on balcony? The Modular System Our modular systems allows us to attach thermally broken bolt on balcony systems to buildings without the need for scaffolding. The system is comprised of a first and a second fix attachment. 1st Fix A specially manufactured sub frame comprised of a thermal break connection, a stub connection & a strap connection are built into the structure of the building, leaving a connection point in the insulated cavity. 2nd Fix This stage takes place when the structure is at the point where the mainframe is completed and the balconies can be safely installed. A completed bolt on balcony is delivered to site and attached to the first fix connection points quickly and efficiently, by our team of highly skilled engineers with the use of our specialist access equipment. Advantages of the Modular System It keeps time on site to an absolute minimum and ensures no risk of damage to external items as the building is being erected. It allows for structural connections to be made between the internal floor slab and the external balcony chassis, without interrupting the continuous thermal insulation of the building. It comes complete with all necessary ThermConX thermal break connections to ensure compliance with all thermal bridging regulations. It is available in a wide range of styles and sizes to suit all architects design and threshold details. It suits all methods of construction from brick and block and wind post through to cast in situ & timber frame. It allows all balcony systems to be manufactured and stored off site. Our Specialist Access Equipment Insulá s range of thermally broken bolt on balconies are modulised balcony systems designed to eliminate thermal bridging. They allow structural connections to be made between external balconies and the internal floor slab, without compromising the continuous thermal insulation of the building. Completely negates the requirement for scaffolding to install external items. Allows for numerous items to be attached in a single day in all weather conditions. Has a footprint of just 1m 2, making it ideal for tight sites where space is at a premium.
5 Introduction What is a thermally broken bolt on balcony? 74 FERMOY ROAD -Sustainable Homes Code Level 4. Developer POCKET DEVELOPERS Architects DARLING ASSOCIATES Balconies by INSULÁ LTD.
6 3 Thermally Broken Bolt on Balconies Balcony Types What makes the bolt on balcony system different? What type of balconies do you supply? We supply Juliette, Access & Walk on balcony systems, all available in a wide range of styles and designs to suit all tastes & design detail. Juliette Balconies Are available in a range of styles to compliment the access and walk on balcony systems that we supply. Access Balconies Are generally used to provide a means by which service persons (ie window cleaners) can safely access and clean the outside of otherwise awkwardly positioned windows or doors. Aside from this purpose, Access balconies also enable a touch of the outside to be bought inside, making them perfect for hot summer nights and long summer days. Walk on Balconies Are available in a range of modern and contemporary styles and can be designed to suit any specification and projection from the building. Because we are able to supply all types of balconies, it is possible to have the same design detail following through all types of balconies on the same development. This allows for aesthetically pleasing and balanced design detail. What makes the bolt on balcony system different? Aside from the unique nature of how the bolt on balcony system works and can be incorporated within all types of construction, there are also other unique features that come as standard: Drainage system All of our balcony systems come supplied with an in built drainage system. The system involves insetting the timber decking into the balcony chassis so that it rests 5mm above the chassis frame. A plastic drip tray is then set underneath the decking to channel any spillages to an outlet pipe mounted to the side of the balcony chassis. This system is essential as it ensures that any water which may find its way on to the balcony floor (via rainwater or spillages) is safely and discreetly chanelled away from the balcony. Anchor Points All of our balcony systems have the option of attached anchor points. Anchor points provide a safe and secure means by which service persons (ie cleaners) are able to securely attach themselves to ensure no risk of accident whilst working at heights. Undertrays Undertrays offer an aesthetically pleasing finishing touch to the balcony. They are available in a range of materials and styles to suit all designs and requirements, from light weight open mesh to a solid metal or plastic panel. Undertrays also ensure that birds are unable to perch or roost in the underside of the balcony chassis and protect neighbours from any spilages etc which may occur. Further details are available via our website. Tel:
7 Thermally Broken Bolt on Balconies Eurokobra Thermal Imaging 4 Testing ThermConX thermal performance We used the EUROkobra computer program extensively in the development and testing of our thermally broken bolt on balcony system. The following diagrams show the dramatic difference between a cantilevered balcony member which bridges the insulation layer and one which does not. This thermal image shows how effectively our ThermConX halts the conduction of heat energy into and out of the building. Thermal Imaging This thermal image shows the cold bridges created by bridging the insulative cavity of the building envelope. Heat energy is conducted in to the balcony chassis via these thermal bridges and then radiated into the atmosphere. As much as 30% of the buildings total heat energy can be wasted in this way. This thermal image shows how a non-thermally broken connection reduces the temperature of the fabric of the building. This thermal image shows how solar heat energy is absorbed into the balcony floor. This heat is then conducted back into the building through the insulated cavity, causing a considerable rise in room temperature. Subsequent energy use is then required by means of air conditioning in order to cool the room down again. Room temperature of +20 degrees C. Relative humidity in the room 60%
8 5 Thermally Broken Bolt on Balconies Chassis & Balustrading Inset or Recessed Inset or Recessed? We supply balconies to suit all types of installation, from a simple cantilever to inset or recessed. Balcony Chassis All of our balcony chassis are designed to meet all standard types of doors and doors with side panels (see table below). A bolt on balcony in plan view with the sides abutting the floor slab. A bolt on balcony in plan view showing a simple cantilever. We are also able to offer bespoke sizes if required, to suit all sizes and design detail. For specific dimensions please contact our design department at [email protected] Chassis Metalwork Typical Door Width Overall chassis width Balustrading All our balustrading designs are based upon either a P.F.C. toes in or P.F.C. toes out system. The P.F.C. toes in system is used whenever a standard balustrading design such as structural glass is required. (See above right) The P.F.C. toes out system allows for more decorative balustrading designs such as elaborate metal post arrangements. (See above left) This system allows us to accommodate all designs of balustrading, from simple and effective to complex and elaborate. All chassis metalwork is fully welded mild steel which is hot dipped zinc galvanized to U.K.A.S. standard BS EN 1461:1999. All mild steel metalwork is zinc passivated up to 30 microns and treated with an acid primer before receiving the final coat of epoxy polyester paint finish to customer s chosen RAL colour. This combination performs the highest level of protection from corrosion with the highest quality of paint finish. All balustrade panels have weld free junctions for a clean and square profile, and all stainless steel fittings are grade 304 satin finish unless specified otherwise.
9 Thermally Broken Bolt on Balconies Balustrading Are there regulations regarding balustrading? 6 What regulations are there regarding balustrading? There are two main building regulations relating to balustrading on balconies. Balustrade compliance with building regulation BS6399 All of the balustrading designs we offer with our balcony range comply with the 1100mm rule and exceeds the level of loading required to meet this standard. (See table below) Type of occupancy for part of the building or structure Examples of specific use Horizontal uniformly distributed line load A uniformly distributed load applied to the infill A point load applied to part of the infill C3 areas without obstacles for moving people Stairs, landing, corridors, ramps, etc Not suspect for over crowding External balconies, roof edges. Pavements within building curtilage Building regulation approved document K2: Protection from falling This regulation sets a minimum height of 1100mm for all guarding. The guarding must be able to resist a minimum force of 0.74kn/m at the top edge. The balustrade must be able to resist a point load equivalent to 50kg through a 50mm square indent when applied to the most vulnerable point knm at the top most point of the balustrading Minimum height of balustrade, 1100mm Finished floor height Tel: +44 (0)
10 First Fix Connection Detail What Is A Stub Connection? Thermally Broken Bolt on Balconies What is a stub connection? A stub connection is a section of steel channel attached at one end to a thermal break connection which then passes through the buildings external wall, leaving a connection point on the outside of the building. What are the benefits of using stub connections? The main advantage of using stub connections is that they can be altered independently in order to accommodate any variables that may arise on site, as is so often the case. One example of this is the knock on effect created if the finished floor height (FFH) of a building is not as it should be. This creates a significant problem when it comes to attaching external items such as balconies, which must be positioned exactly flush with the floor level. When using stub connections, should an error like this occur it is possible to simply unbolt and remove the section of stub beam from within the first fix connection point(s). Then it is simply a case of re-measuring and manufacturing a new, specialist stub connection to ensure that the connection plate will once again be positioned correctly on the outer face. The pictures below show how a stub connection is incorporated within a wind post method of construction, before and after the the insulation and external wall has been erected. Before After A typical stub connector within a wind post system before the insulation and external wall have been built. Once the structure has been completed just the connection points are visible.
11 Thermally Broken Bolt on Balconies First Fix Connection Detail Pre-cast Concrete Construction 7 How does the First Fix system work? There are three separate elements which constitute the first fix detail of one of our ThermConX thermal break connection systems. It is essential that each element of our first fix system is installed correctly as it is this system which determines how the balcony system is attached to the structure of the building. We have a selection of first fix connection details to suit all methods of construction. Below are representations showing the slight differences between our first fix systems which allows for them to be accommodated within these varying methods of construction. Pre-cast Concrete To see these connection diagrams in more detail, please visit our website.
12 8 First Fix Connection Detail Wind Post Construction Thermally Broken Bolt on Balconies Wind Post Construction To see these connection diagrams in more detail, please visit our website.
13 Thermally Broken Bolt on Balconies First Fix Connection Detail Cast in Situ Construction 9 Cast in situ construction To see these connection diagrams in more detail, please visit our website.
14 10 First Fix Connection Detail Wooden Floor Joist Construction Thermally Broken Bolt on Balconies Timber Frame Building Eco Joist Wooden Floor Joist To see these connection diagrams in more detail, please visit our website.
15 Thermally Broken Bolt on Balconies Advantages Summary 11 Advantages Here are some of the unique advantages of the ThermConX thermal break bolt on balcony system: It offers compete compliance with the latest Part L & NBS building regulations regarding thermal bridging It allows structural connections to be made between the internal floor slab and the external balcony chassis, without interrupting the continuous thermal insulation of the building. The bolt on systems can be easily adapted in order to accommodate any variables that may arise on site. The modular bolt on system keeps time on site to an absolute minimum whilst ensuring a high quality, factory produced product each and every time. The bolt on system suits all methods of construction, from cast in situ and pre-cast concrete to wind post & timber frame. Our specially designed access equipment allows us to install numerous balcony systems in a single day, without the need for scaffolding and in all weather conditions. All our ThermConX bolt on systems guarantee complete resistance to the passage of sound, and complete compliance with the new part E building regulations. Summary There has never been a more important time for lateral thinking within the construction industry, in order to satisfy the ever growing demand for more versatile and efficient building products, than there is now. Our ThermConX bolt on balcony system is the most versatile and efficient balcony system the world has ever seen. It offers clients an unrivaled flexibility and freedom of choice in the balcony and balustrading design detail available. The flexibility of using a system such as this, which can be adapted to accomodate any number of variables which may arise on site offers the contractor a piece of mind rarely encountered within the construction industry. With a library of countless technical design details, and the expertise of numerous years experience in all sectors of the construction industry, we pride ourselves on providing a hassle free, one stop shop service to solve all your cold bridging and balcony requirements. For complete access to our range of technical details please visit our website at Insula s ThermConX bolt on balcony system. The only 100% solution.
16 12 Thermally Broken Bolt on Balconies Disclaimer This document is the property of Insulá limited its subsidiaries or affiliates. All of the materials contained within it, including without limitation all editorial materials, informational text, photographs, illustrations, artwork, graphics, layout, names, logos, trademarks and service marks are the property of Insulá or its licensors and are protected by copyright, trademark and intellectual property laws of the United Kingdom and other countries. Users are advised that the information contained herein is subject to change and may not be current. Insulá limited takes reasonable care in preparing the material in this document, but disclaims any duty to update such information. Insulá limited cannot guarantee the accuracy, completeness, timeliness or reliability of this information and is not responsible for any damage or loss resulting from a failure to update. Use of this document is at the risk of the user. Insulá Limited assumes no responsibility or liability for damage. Any information in this document pertaining to the company's products is provided as a convenience to the users and does not constitute an offer to sell or otherwise obligate Insulá limited in any way. Insulá limited specifically disclaims all warranties of any kind, expressed, implied, or otherwise, including without limitation warranties of merchantability, fitness for particular purpose, or non-infringement. In no event shall Insulá limited be liable for damages, including special, incidental, indirect or consequential damages or for loss of use, data, or profits, under any theory of liability, arising out of or in connection with these materials. Copyright 2008 Insulá. All rights not expressly granted herein are reserved. Material in this document may be used for personal reference only. It may not be reproduced, modified, published, distributed, displayed, retransmitted in any form, nor used for any commercial purpose, without the express written permission of Insulá Limited.
17 Thermally Broken Bolt on Balconies Contact Us Insulá Hathern Industrial Estate Rempstone Road Normanton On Soar Leicestershire LE12 5EW Tel: +44 (0) Fax: +44 (0) Web:
Energy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
Fire Resistant Systems
Fire Resistant Systems A R C H I T E C T U R A L A L U M I N I U M G L A Z I N G S Y S T E M S Fire Resistant Systems Introduction Kawneer are pleased to introduce two new comprehensive Fire Resistant
Small-scale poultry keeping housing layers
NOVEMBER 2007 PRIMEFACT 603 (REPLACES AGFACT A5.7.9) Small-scale poultry keeping housing layers Intensive Livestock Industries Development Introduction Poultry of all types require housing that will protect
PivotLoc Ladder Systems
N25 ACCESS AND SAFETY EQUIPMENT SPECIFICATION CLAUSES PivotLoc Ladder Systems To be read with The Main Contract Preliminaries, General Conditions, Sub-Contract Preliminaries. MINIMUM CONTRACTOR STANDARD
Rockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
Park View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.
The Townhouses Park View Place A A Compass House A T T T Royal Wharf Gardens Endeavour House T A A Thameside House T Sienna House A A A A T Apartments Townhouses River Thames Compass House Compass House
1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
1/9/13 By Brett T. Fagan, P.E. Presented by Marie Horan, P.E. Building Diagnostics, Inc. Building Diagnostics Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
Module 3.7. Thermal bridging
Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
HANDRAIL STANDARDS HANDRAILS AXESS LADDER SYSTEM KICK FLAT SYSTEM OPEN FLOORING
ENGINEERING LTD. HANDRAIL STANDARDS HANDRAILS AXESS LADDER SYSTEM KICK FLAT SYSTEM OPEN FLOORING Member of PF Group Guardrail Engineering Limited Manders Industrial Estate Old Heath Road Wolverhampton
technology UICK progressive sustainable any design, any shape, any colour, anywhere you like!
uality using advanced building technology UICK uality innovative progressive sustainable any design, any shape, any colour, anywhere you like! 2 NicheQ is an award winning progressive and innovative builder
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010
Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance
Confort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
Mini-ITX Addendum Version 1.1 To the microatx Motherboard Interface Specification Version 1.2. April 2009
Mini-ITX Addendum Version 1.1 To the microatx Motherboard Interface Specification Version 1.2 April 2009 1. INTEL CORPORATION ( INTEL ) MAKES NO WARRANTIES WITH REGARD TO THIS SPECIFICATION ( SPECIFICATION
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
Dubai Municipality Standard DMS 1: Part 5: 2004
Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue
SOLAR HOT WATER SOLUTIONS stainless steel roof systems
SOLAR HOT WATER SOLUTIONS stainless steel roof systems RHEEM. SINCE 1937. Rheem has been manufacturing in Australia since 1937. Over seventy-five years later, Rheem is a household name and is as much a
TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING
6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry
Plaisance 24. Sliding Systems. Sapa Building System
Plaisance 24 Sliding Systems Sapa Building System Plaisance 24 is Sapa s noninsulated sliding system for windows and doors. Available as one-, two-, three- and fourrail solution. Among its features, there
Building Control Guidance Note
Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY
PERFORMANCE CEILINGS M ore s c op e f or i n n ovat i on AMF Line; wall absorbers Wall mounted acoustic designs MADE IN GERMANY 138568_Prospekt Wandabsorber_GB int.indd 1 Acoustic elements on the wall
GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY
GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY July 2008 1.0 SCOPE These guidelines describe the way in which air conditioning units shall be installed or replaced
LAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
Dock Hardware & Accessory Products Catalog
Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set
A few good reasons to have a conservatory. The conservatory structure
Conservatory styles A few good reasons to have a conservatory The conservatory structure PLAY FAMILY TIME In essence a conservatory is like a big jigsaw with all the pieces joining together to form a finished
TARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
Plaisance 50. Windows and doors. Sapa Building System
Plaisance 50 Windows and doors Sapa Building System Plaisance 50 is a non-thermally broken system for aluminium windows and doors with a building depth. The system offers a wide range of inward and outward
ANI-64S-xRU. Single Section Wall Cabinet INSTRUCTION MANUAL
ANI-64S-xRU Single Section Wall Cabinet INSTRUCTION MANUAL 122 Rose Ln., Suite 303, Frisco, Texas 75034 TOLL FREE: 1-877-ANEUTRON TOLL: (469) 362-9228 Email: [email protected] A-Neutronics.com SAFETY
Cheshunt Fabrications Ltd
Cheshunt Fabrications Ltd Unit 9a & 9b, Quickbury Farm Hatfield Heath Road Sawbridgeworth Hertfordshire CM21 9HY Phone: 01279 600866 Fax: 020 8609 0050 01279 600868 www.fabber.co.uk Quality in the making
7. Installation. installation 7.1.1. CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME
7. Installation Window involves the fixing of window frame at an earlier construction stage and subsequent of the window sashes. This is a highly workmanship dependent process. Only trained and approved
Elegance SC. Solar Control
Elegance SC Solar Control Sapa Building System Building Understanding In an age of global warming, the reduction of carbon emissions is a key factor when both selecting materials for a building and how
Saint Cloud Business Center
Saint Cloud Business Center 14 7th Avenue North Saint Cloud, MN 56303 For Sale Located on 7th Avenue in the heart of downtown across from the Court House Square. A large professional reception area with
The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.
26 D+D MARCH 2015 Building Envelope Roland Serino, P.E., Dryvit Systems Inc. here has always been a need for a more efficient way to build in large cities like Chicago, New York, Los Angeles or other central
SL30-ISO PROFILE SYSTEM
AESTHETICS AND sustainability SL30-ISO PROFILE SYSTEM TECHNICAL DOCuMENTATION WWW.MHB.NL SL30-ISO PROFILE SYSTEM 1. SL30-ISO and SL30-ISO-PLUS Sustainability is getting worldwide more and more the attention
All Weather Hall. Efficient, multipurpose & quick to build
All Weather Hall Efficient, multipurpose & quick to build ALL WEATHER HALL www.deboer.com www.deboer.com ALL WEATHER HALL A flexible solution for a multitude of needs All Weather halls from De Boer provide
Residential Prototype III. Multi-Story. The Multi-Story. Your connection to ideas + answers. Prepared by: AISC Steel Solutions Center
Multi-Story Residential Prototype III The Multi-Story Residential Prototype III Prepared by: AISC Steel Solutions Center What s this? This package tells the story of a fictitious project with an imaginary
Timber Decks. Technical Note. March 2007
Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.
Company DUOL. Dušan Olaj CEO
Company DUOL Company DUOL has been active on the market since 1992 and throughout this period Duol has successfully attained the position of one of the most significant suppliers of fabric structures.
The Warm Edge for insulating glass
The Warm Edge for insulating glass 1. 3. SGGSWISSPACER 2. 4. The best product on the market by quite an edge Energy saving Lower heating costs through better insulation: the thermally improved spacer SGG
Innovators in steel buildings Innovators in steel buildings CEPTRA
Innovators in steel buildings Innovators in steel buildings CEPTRA It takes At Frisomat, all good things come in 2 s. It only takes 2 to assemble a building, from 2 weeks to 2 months. How? As the only
ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape
ModuSec Secure and efficient IT room solutions Turnkey Modular Construction Fast clean build to any size or shape Room in room Standalone external build Transportable Modusec SR Options Modusec SR Options
EAST LYME HIGH SCHOOL
Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed
0845 0098 980 www.nicholsonsts.com
0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution
Multi-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
Connection Solutions
Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012)
de Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012) Introduction The rules governing permitted development (that is, whether
Ruukki Finnera. The most intelligent roof ever seen.
Ruukki Finnera The most intelligent roof ever seen. Finnera s new and innovative design makes your steel roof not only beautiful but also extremely durable and practical. The revolutionary front-edge folding
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37
Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details
V-joint fascia soffit systems
V-joint fascia systems CI/SfB October 2005 (4-) Uniclass L5294 extruded aluminium system with complete versatility for eaves and other building features Bailey V-Joint and fascia system has been designed
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
Partitioning & Ceiling Product Information
Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email [email protected] web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44
Shower and Floor Gullies Channel Drain and Tile Drain SECTION
Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions
ALTAIR LOUVRE WINDOWS for Commercial Buildings
ALTAIR LOUVRE WINDOWS for Commercial Buildings Picture: Manea Tafe College, Bunbury, WA 2009 Australian Institute of Architects Award for Public Architecture. Breezway Philosophy At Breezway we believe
Building Code Clarifications - 7. Fire Resistance
Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,
The Guide To Waterproofing An Existing Basement
The Guide To Waterproofing An Existing Basement John Newton & Company is the leading independent supplier of basement waterproofing and damp proofing solutions in the UK. Newton System 500 is a maintainable
Extracts from BUILDING REGULATIONS
Page 1 of 3 UNotes on Building Regulations Please note that British building regulations are complex and that they may vary from area to area. It is your responsibility to ensure that your chosen stair
Can you design a frameless shower enclosure that doesn't leak?
Can you design a frameless shower enclosure that doesn't leak? With proper design and installation frameless shower enclosures should not have any problems with water leakage, but they are not 100 percent
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
Mini-ITX Addendum Version 2.0 To the microatx Motherboard Interface Specification Version 1.2. October 2010
Mini-ITX Addendum Version 2.0 To the microatx Motherboard Interface Specification Version 1.2 October 2010 1. INTEL CORPORATION ( INTEL ) MAKES NO WARRANTIES WITH REGARD TO THIS SPECIFICATION ( SPECIFICATION
faraday HOUSE CANNING TOWN STATION LIGHTHOUSE BUILDING
faraday UIDI faraday UIDI M A AI TO STATIO faraday UIDI OUdry UIDI ATE HOUSE E D TRIITY SQUARE ORHARD PAE H K I ISAD RIDE ORHARD UIDI IHTHOUSE UIDI REATIVE OIE ARADAY UIDI EVE EED : alcony : upboard :
Composite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
SWIMMING POOL, SPA, & HOT TUB GUIDELINES
SWIMMING POOL, SPA, & HOT TUB GUIDELINES Pool permit cost is based on the total value of the project. See Permit Fee Schedule Table 1A. A. Adopted construction codes and installation requirements 1. 2015
Innovators in steel buildings. Innovators in steel buildings astra
Innovators in steel buildings Innovators in steel buildings astra It takes At Frisomat, all good things come in 2 s. It only takes 2 to assemble a building, from 2 weeks to 2 months. How? As the only international
Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses
Passiv Haus Institut Passivhaus Dienstleistung GmbH Dr. Wolfgang Feist Rheinstr. 44/46 Rheinstr. 44/46 D-64283 Darmstadt D-64283 Darmstadt www.passiv.de www.passivhaus-info.de Certification as "Quality
Installation Instructions
Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email [email protected] Phone:
HANLO The WELCOME HOME Experience.!! Simply better homes!!
HANLO The WELCOME HOME Experience!! Simply better homes!! The Mission Our mission is to provide individual, sustainable and affordable homes to self builders and developers that can be built fast, efficient
Uncovered Decks & Porches
Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
Innovators in steel buildings Innovators in steel buildings ASTRIGMA
Innovators in steel buildings Innovators in steel buildings ASTRIGMA It takes At Frisomat, all good things come in 2 s. It only takes 2 to assemble a building, from 2 weeks to 2 months. How? As the only
Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.
Self-Cleaning The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Conservatories bringing the outside in. Pilkington Activ has made
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
OIL SPILL CONTAINMENT CONTAINERS AND RACKING
www.lubecontrol.com.au OIL SPILL CONTAINMENT CONTAINERS AND RACKING Lube Control Pty Ltd Providing lubrication solutions! Unit 5/53 Norfolk Rd, Marion, SA 5043 t: (08) 8298 5563 f: (08) 8298 6253 e: [email protected]
Conservatory warm roof conversion system
Conservatory warm roof conversion system IS YOUR EXISTING CONSERVATORY ROOF: Too hot in summer or too cold in winter? Waste of valuable living space? Unable to relax to watch TV? Transform your conservatory
Specification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31.
Uniclass L411 +L413:P7114 EPIC D11 +D13:X725 CI/SfB (31.4)+(31.5) Xn6 9/11 SmartSash A BRAND OF THE VEKA UK GROUP Specification Guide Fenestration Solutions for Public Sector & Commercial Applications
Rockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
Includes specifications for: Surface Cleaning & Mounting Hardware.
Three-Part Specifications - Copyright 2014 - Nixalite of America Inc Bird Screen Welded Wire Mesh Barriers Includes specifications for: Surface Cleaning & Mounting Hardware. Nixalite offers full rolls
Unbeatable energy efficient glass curtain wall system
Unbeatable energy efficient glass curtain wall system CONTENT Introduction 1 System 2 World Class Engineering 4 Unit Selection 5 Energy Efficiency & Comfort 10 Maximised Installation Efficiency 12 Aesthetics
9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.
Section 9.8. Stairs, Ramps, Handrails and Guards 9.8.1. Application 9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and
Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 [email protected]
CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can
Building Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
SOLAR HOT WATER SOLUTIONS Ground Systems
SOLAR HOT WATER SOLUTIONS Ground Systems RHEEM. SINCE 1937. Rheem has been manufacturing in Australia since 1937. Over seventy-five years later, Rheem is a household name and is as much a part of the fabric
Tel: 0800 975 4933 Sales: [email protected] STORAGE CABINETS. PREMIERSHIELD anti-bacterial powder coating system. quality products made in the UK
Tel: 0800 975 4933 Sales: [email protected] STORAGE PREMIERSHIELD anti-bacterial powder coating system quality products made in the UK MEDIUM DUTY : 88 SERIES PREMIER BDU DESK UNITS: 88 SERIES Of welded
Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments
Cannon T4 Modular Data Centres For Outside Deployment & Challenging Environments A high performance, full specification Data Centre, up to Tier 4* resilience, instantly deployable A highly secure Data
Residential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: [email protected] Planning and Development Services Department Residential Decks
I-Line - Snap-On Feature
Oct 2012 I-Line - Snap-On Feature DATA SHEET Snap-On features - Guaranteed truelines every time Bailey I-Line Snap-On is an architectural cladding feature offering creative possibilities for architects
Preparing a maintenance plan
The maintenance series Information sheet 1.1 Preparing a maintenance plan Introduction The regular expenditure of a small amount of maintenance funds is much better for a building, and more cost effective,
Installing the Sno-free Standing Seam System for Metal Roofs
Installing the Sno-free Standing Seam System for Metal Roofs SFP SSP CLIP SSP STANDING SEAM SFP EXTRUSION SFP RAMP PANEL Step # 1 Mark the location and Install Extrusion Mark the area on the roof to receive
DENVER MODEL 30 X 30 SPECIFICATIONS
DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch
Approved Document Q: Security
Approved Document Q: Security Requirement Q1 Unauthorised access Consultation draft September 2014 1 The approved documents What is an approved document? The Secretary of State has approved a series of
Server Chassis and Triplet Hardware v1.0
Server Chassis and Triplet Hardware v1.0 Author: Steve Furuta, Mechanical Designer 1 Scope This document describes the technical specifications for the custom chassis used in Open Compute Project servers
ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION
The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 E1 E2 E3 E4 E Protection against sound from other parts of the building and adjoining buildings Protection against
Glass and Building Regulations Impact Safety
Glass and Building Regulations Impact Safety England and Wales Approved Document N Scotland Part P Northern Ireland Part V Foreword For new buildings, and for buildings subject to major refurbishment,
Peninsula Place, Greenwich, London
Concepts Products Service Peninsula Place, Greenwich, London 1 Project Report Peninsula Place, Greenwich, London Designed as one of the most sustainable commercial buildings in the UK, with a BREEAM rating
We re about to build.
We re about to build. Get out there boys! every new home is a possible new dinner menu! What do we need to know about dealing with termites? A Managed Approach is Best! There are more than three hundred