PATHFINDER FOAM CALIPER PIG Case Study 12 REFINED PRODUCTS PIPELINE, NAPLES ITALY. Pipeline Innovations Ltd. The Problem
|
|
|
- Lucy Clark
- 9 years ago
- Views:
Transcription
1 PATHFINDER FOAM CALIPER PIG Case Study The Problem 12 REFINED PRODUCTS PIPELINE, NAPLES ITALY Exxon Mobil own a 12 x 3.5km refined products pipeline that runs from a dockside terminal to a tank farm on the outskirts of Naples, Italy. The line had been decommissioned in preparation for MFL inspection but it had never previously been pigged. Before running the MFL tool, the line was proved by running a foam pig through it then a bi-di gauging pig was launched to help quantify any risk to the MFL inspection tool. Unfortunately, the gauging pig became stuck in the line and had to be cut out. When the pipe was cut open, it became apparent that the pig had been obstructed by internal ring anodes, which had been dislodged by the gauging pig causing it to hang up as it traversed a bend. Bi-Di Pig with Dislodged Anodes The internal anodes are in the form of a circumferential ring, approximately 5mm to 10mm thick and 100mm wide, which are held in place by straps welded onto the inner surface of the pipe. Corrosion appears to have weakened some of the welds on these straps and the force applied by the passage of the pig through the line was enough to rip some of the anodes off the wall. The pipeline records contained no information regarding numbers or locations of these anodes and it was obviously vital to understand the extent of the problem before attempting to run the more complex MFL or UT pigs through the line. The client was understandably concerned about using a regular caliper pig to survey the line, in case it also became stuck. PIL were approached and asked whether the new Pathfinder Foam Caliper might be a suitable alternative to a hard bodied type of caliper and what level of information could be obtained by running it in the line. PIL's response was that the tool was designed to fulfil exactly the role required in this instance and that the data obtained is very similar to that from a caliper tool. Page 1
2 After some consideration, PIL proposed a two stage program: Stage 1 Design and build a caliper foam pig suitable for the Naples pipeline and carry out acceptance tests in PIL s test loop, with simulated anodes and 1.5D back to back bends as were present in the target line. Stage 2 Mobilise foam calipers and engineer to Naples. Carry out caliper survey of the 12 pipeline and produce preliminary and final survey reports. Stage 1 Preliminary Loop Testing Preliminary loop testing was carried out using the PIL test loop facility in the North East of England. The tests included assessing the performance of 12 (308mm OD) foam calipers in a full bore unbarred tee, a 3D 90 º schedule 80 bend and in straight pipe bores of 303mm, 289mm and 273mm. In addition, a simulated internal anode was produced and the response of the pig to the anode was assessed. These tests showed that the foam caliper was fully capable of detecting the bore changes and pipe features, including the simulated anode, while having no problem in negotiating any of these features. Final Pig Design The final pig design featured a profiled nose section, which was coated with PU to minimise damage from the anodes. The client had requested the addition of an E.M. transmitter to the final pig design, for location in the event that this pig also became stuck in the line. A suitable transmitter was sourced and the internal design of the pig was modified to accommodate it. A number of foam pig vehicles were produced and, with the caliper electronics module fitted, each pig was repeatedly run through the loop in order to assess the wear rate and any potential damage from the anodes. The test data was analysed and repeatability assessed. The outcome of the tests was satisfactory in all respects. Acceptance Testing Acceptance testing comprised a witnessed program of further tests in the loop, with the addition of an arrangement of back to back 1.5D bends supplied by the client, and an additional simulated anode positioned on the exit from the bend. 1.5D Back to Back Bends Simulated Anode Ring Page 2
3 Stage 2 Foam Caliper Survey The foam caliper survey was carried out in conjunction with Tecma Pipeline Services S.r.l who provided the operations support for running the pig. The caliper measurement pod was powered up and inserted into the pig body, followed by an electromagnetic transmitter and the retaining cap. Caliper Pod EM Transmitter The foam caliper was loaded into a temporary launcher at the terminal end of the pipeline and it was pumped through the line, using water, to the receiver in the tank farm. Ready for launch Loading The pig run took approximately 3 hours, with the pig running at an average speed of about 0.3m/s. On completion of the run, the front section of the pig was found to have suffered significant damage but the rear section, where the caliper system is located, was in relatively good condition. Page 3
4 Anode Retaining Strap Embedded in Foam Body The damage to the front of the pig included: Part of the PU coating on the nose of the pig was missing Pieces of foam from the front section of the body had been torn out A large tear was present just behind the tapered nose section which extended around most of the circumference and penetrated deep into the structure of the pig body An anode retaining strap was embedded in the foam about 100mm behind the tapered nose The caliper measurement pod was removed from the pig and the data downloaded to a laptop. It was found that a full dataset had been recorded and the quality of the data was good. Data Analysis - Bends Using the characteristic response of the caliper sensors it was possible to identify bends in the pipeline. Also, by using the roll position sensors and the tilt sensor, it was possible to determine the direction of the bends and sections of rising or falling pipe. A total of 80 bends or bend combinations were identified in the data and, by reference to the strip maps of the pipeline, it was possible to correlate bends identified in the data with bends indicated on the maps. As the bends were distributed along the length of the pipeline, this provided regular markers in the time based data, allowing us to accurately identify the location of other features in the line. Data Analysis - Anodes Anode features in the line were identified by comparison with the caliper response to simulated anodes in the test loop at PIL. Examples of the test loop response and the response in the pipeline are shown below: Page 4
5 Test Loop Anode Response Pipeline Anode Response Sample Of Data From Pipeline Showing 2 Bends and 6 Anodes A total of 144 internal anode features have been positively identified in the data. Using the bend marker data, it has been possible to identify and mark the location of each of the anodes on the strip maps. Page 5
6 Conclusion Pipeline Innovations Ltd The first operational project for the foam caliper tool has proved to be very successful with the performance of the tool exceeding all expectations. Faced with a pipeline exhibiting severe pigging difficulties, the client was unable to progress with the use of any type of internal inspection tool to assess the integrity of the pipeline, until the extent of the problem had been identified. With the Pathfinder Foam Caliper tool, PIL were able to offer the client a unique solution to this problem. The tool was able to traverse the full length of the line and, despite suffering significant damage to the front of the pig body, the caliper system continued to operate and collect good quality data throughout the complete length of the line. Using the caliper data from the Pathfinder tool and by reference to the existing strip maps, it has been possible to identify and locate 144 internal anodes in the line. Knowledge of the number, location and distribution of the problematic internal anodes will now allow the Pipeline Engineers to make informed decisions on how to move the project forwards. Acknowledgements Pipeline Innovations Ltd, gratefully acknowledge the contribution of the following to the successful completion of this project: Wilson Santamaria, European Pipeline Integrity Head - ExxonMobil. Ralph Lowe, Pigging Consultant, UK Raffaele Zaffaroni, Tecma Pipeline Services Srl, Italy Contact Pipeline Innovations Ltd Unit 13E Atley Way Cramlington Northumberland, UK NE23 1WA Tel: +44(0) (Direct) Mobile +44(0) [email protected] Web: pipeline-innovations.com Page 6
DEVELOPMENT OF THE PATHFINDER FOAM CALIPER PIG. By: Peter Ward, Pipeline Innovations Ltd, UK
DEVELOPMENT OF THE PATHFINDER FOAM CALIPER PIG By: Peter Ward, Pipeline Innovations Ltd, UK Background In 2005, Total were planning to carry out an inspection of two 32 gas and condensate pipelines running
Vertiline. Wireline-conveyed MFL inspection service reduces pipeline maintenance and rehabilitation costs. Baker Atlas
Vertiline Wireline-conveyed MFL inspection service reduces pipeline maintenance and rehabilitation costs Baker Atlas The Vertiline wirelineconveyed Magnetic Flux Leakage (MFL) instrument provides quantified
PIPELINE PIGGING SERVICES BY IIRCO.
PIPELINE PIGGING SERVICES BY IIRCO. WHY PIPELINE PIGGING? There are some hypotheses for why the process is called pipeline pigging, though none have been confirmed. One theory is that pig stands for Pipeline
PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany
ABSTRACT: PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany Today, in-line inspection tools are used routinely
Ultrasonic Guided Waves Evaluation of Trials for Pipeline Inspection
17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Ultrasonic Guided Waves Evaluation of Trials for Pipeline Inspection Francisco C. R. MARQUES 1, Alessandro DEMMA 2 1 E&P
PIPELINE INSPECTION USING INTELLIGENT PIGS AN SGA/BATTELLE WORKSHOP COLUMBUS, OHIO MAY 11-14, 2010 AGENDA
Day One PIPELINE INSPECTION USING INTELLIGENT PIGS AN SGA/BATTELLE WORKSHOP COLUMBUS, OHIO MAY 11-14, 2010 Westin Columbus Hotel 7:15 Continental Breakfast AGENDA Session 1 8:00 10:00 An Introduction to
NCCER 13614 Progress Blvd., Alachua, FL 32615 Tel: (888) 622-3720 E-mail: [email protected]. Task Number Item Date(s) Recorded By
NCCER 13614 Progress Blvd., Alachua, FL 32615 Tel: (888) 622-3720 E-mail: [email protected] PIPELINE MAINTENANCE On-the-Job Training Level One MODULE 66101-02 INTRODUCTION TO THE PIPELINE INDUSTRY This is
SCALE ASSESSMENT PIGGING OF THE TOTAL DUNBAR 16 MULTI-PHASE PIPELINE
OPT Conference & Exhibition March 1 & 2, 2005 Amsterdam SCALE ASSESSMENT PIGGING OF THE TOTAL DUNBAR 16 MULTI-PHASE PIPELINE Gordon Allan Pipeline Inspection Manager Weatherford Pipeline & Specialty Services
Webinar Series. Committee. Disc Brake Wheels Off Inspection and Reline. Presents
1 APTA Bus Webinar Technical Series Maintenance Committee Webinar Series Presents Disc Brake Wheels Off Inspection and Reline January 21, 2015 2 Introduction Welcome to today s webinar in which we will
SMALL DIAMETER, MULTIPLE DATASET INSPECTION IN LOW FLOW AND LOW PRESSURE ENVIRONMENTS
WHITE PAPER 15-01 SMALL DIAMETER, MULTIPLE DATASET INSPECTION IN LOW FLOW AND LOW PRESSURE ENVIRONMENTS Chuck Harris T.D. WILLIAMSON HOUSTON, TEXAS [email protected] Mark Graves WILLIAMS OKLAHOMA
Pipe Inspection Carbon Steel Trials
Pipe Inspection Carbon Steel Trials Client Innospection Limited Facility Head Office Aberdeen Item Inspected Pipe No 1 Inspection Method SLOFEC Date Commenced 01/01/2009 Date Completed 10/01/2009 Type
API Std 53 - Blowout Prevention Equipment Systems for Drilling Wells Last update: August 12, 2015
6.1.2.12 53-03-15 Referring to Section 6.1.2.12, can a surface BOP stack arrangement with one annular, one blind shear ram, and two pipe rams, with the fifth device being optional, be considered a Class
The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
Section 33 0200- Page 1 of 4 PART 1 - GENERAL 1.1 DESCRIPTION OF WORK The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
Force Main Condition Assessment: New Technologies & Case Studies
Force Main Condition Assessment: New Technologies & Case Studies Andy Dettmer, Ph.D., P.E. CMOM Workshop August 19, 2014 2 1 Three takeaways 1. Most of your force mains are good 2. We can pinpoint the
OSHA 1910.66 Remove impacted systems and components. Inspect systems prior to use.
Q: When do I remove my harness from service? A: ANSI (American National Standards Institute) A10.32-2004 states the service life of fall protection equipment manufactured of synthetic fiber shall be 5
A World Class Manufacturer of Induction Bends
A World Class Manufacturer of Induction Bends COFELY FABRICOM BENDING A leading position in bending High Flexibility and Close Tolerances As a world leading manufacturer of pipe bends, produced by induction
Rehabilitation of corroded pipelines and pipes with FibaRoll
Rehabilitation of corroded pipelines and pipes with FibaRoll Available exclusively from FTi Ltd Adheres to steel High tensile strength High flexural strength Corrosion protection Cost effective Simple
NSW Licensed Pipeline Performance Reporting Guidelines
NSW Licensed Pipeline Performance Reporting Guidelines NSW Trade & Investment Resources and Energy Division GPO Box 3889 Sydney NSW 2001 Rev Jan 2012 NSW T & I Division of Resources and Energy Contents
Front axle components, overview
just a test. Front axle components, overview 40-1 General Information Load bearing components and parts of the suspension must not be welded or straightened. Vehicles without drive axle must not be moved,
Oil and Gas Pipeline Design, Maintenance and Repair
Oil and Gas Pipeline Design, Maintenance and Repair Dr. Abdel-Alim Hashem Professor of Petroleum Engineering Mining, Petroleum & Metallurgical Eng. Dept. Faculty of Engineering Cairo University [email protected]
COATING & WRAPPING OF UNDERGROUND PIPING
CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification
Flow Assurance & Operability
Flow Assurance & Operability Erosion due to sand production Date Business Name Overview 1. What causes erosion? 2. Sand production and transport 3. Sand management 4. Instrumentation / monitoring of sand
Gear PEPSI CAN STOVE INSTRUCTIONS
Gear PEPSI CAN STOVE INSTRUCTIONS [NOTE: Updated Instructions are now available. The new stove is less likely to develop flame leaks and the fuel/air mixture is improved. Instructions for a simmer ring
Specifications and requirements for intelligent pig inspection of pipelines
Specifications and requirements for intelligent pig inspection of pipelines Version 2009 1 Contents Page 1. Introduction 4 2. Standardisation 4 2.1 Definitions 4 2.2 Abbreviations 7 2.3 Geometrical parameters
In-line inspection (intelligent pigging) of offshore pipeline. Birger Etterdal 2011-11-14
In-line inspection (intelligent pigging) of offshore pipeline Birger Etterdal Content Type of defects Different inspection tools Objective of any inspection Focus on corrosion mapping for submarine pipelines
High Capacity Helical Piles Limited Access Projects
High Capacity Helical Piles Limited Access Projects Tel 403 228-1767 Canada, USA, Russia Brendan ODonoghue 519 830-6113 Presentation Summary 1. Helical piles Background on large diameter shafts and helices
2008 ACCORD - Front Knuckle/Hub/Wheel Bearing Replacement (page 18-13)
2008 ACCORD - Front Knuckle/Hub/Wheel Bearing Replacement (page 18-13) Exploded View Special Tools Required Ball joint remover, 28 mm 07MAC-SL0A202 Hub dis/assembly tool 07GAF-SD40100 Bearing driver attachment,
The Crankshaft Oil Seal Section has been added to the DD15 Workshop Manual. The sections that are found in the Engine Chapter are now renumbered.
NUMBER: 08 DD15-5 S.M. REF.: 1.11 ENGINE: DD15 DATE: July 2008 SUBJECT: CRANKSHAFT OIL SEAL SECTION PUBLICATION: DDC-SVC-MAN-0002 The Crankshaft Oil Seal Section has been added to the DD15 Workshop Manual.
Pipeline Replacement using Relining
Pipeline Replacement using Relining Mark Heathcote, March 2006 Relining of old pipeline systems is becoming an increasingly attractive option to asset owners and operators as an effective alternative to
Pressure Vessel Assessment Report
Project Information Client: Total Energy Location: Blackwell OK Date: 7/23/2013 Contact: Integrity Mgmt. Advisor: Chuck Easterbrooks - API 510 #2212 Cc: API / UT Inspector: Robert Van Pelt-API 510# 40899
TUTORIAL. REbUILdING. front CALIpER O-RING CONVERSION CORVETTE 1965-82. Part #: HT-1
Part #: HT-1 1965-82 CORVETTE O-RING CONVERSION front CALIpER REbUILdING TUTORIAL Choosing a Brake Caliper Rebuild Kit Standard Lip Seals vs. O-Ring Seals Lip seal design seals are used on 1965-1982 Corvette
TUTORIAL. REbUILdING. REAR CALIpER O-RING CONVERSION CORVETTE 1965-82. Part #: HT-2
Part #: HT-2 1965-82 CORVETTE O-RING CONVERSION REAR CALIpER REbUILdING TUTORIAL Choosing a Brake Caliper Rebuild Kit Standard Lip Seals vs. O-Ring Seals Lip seal design seals are used on 1965-1982 Corvette
MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT
Record MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Abandoned Gravity Private Combined Gravity Private Foul Gravity Private Surface Water Gravity Public Combined Gravity Public Foul Gravity Public
Long-distance Pipeline Pigging Technology
Abstract Long-distance Pipeline Pigging Technology Lihang Wang, Pingping Sun School of Yangtze University, Wuhan 430100, China Pigging operation is an important task for long distance pipeline before or
BICYCLE PUMP AIR PRESSURE ROCKETS Credit: Jeff Elmer, Physics Teacher, Oshkosh North High School
BICYCLE PUMP AIR PRESSURE ROCKETS Credit: Jeff Elmer, Physics Teacher, Oshkosh North High School Concepts Illustrated: (1) Forced air flight and Newton s 3 rd Law (2) Stability and aerodynamics of rocket
Lenntech. 1000 psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503
1 User s Guide to: Phoenix Vessel Technology Limited 1000 psi End port pressure vessels 2.5. Model number: 1503 Lenntech [email protected] Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Phoenix
Electric Heat Tracing INSTALLATION PROCEDURES
INSTALLATION PROCEDURES The following installation procedures are suggested guidelines for the installation of a Thermon electric heat tracing system 1. Individuals installing these products are responsible
2007 Hummer H3. 2007 BRAKES Disc Brakes - H3. Fastener Tightening Specifications Specification Application
2007 BRAKES Disc Brakes - H3 SPECIFICATIONS FASTENER TIGHTENING SPECIFICATIONS Fastener Tightening Specifications Specification Application Metric English Backing Plate Bolts 135 N.m 100 lb ft Brake Hose
OD 1401 9 PRECISION MEASURING INSTRUMENTS
SUBCOURSE EDITION OD 1401 9 PRECISION MEASURING INSTRUMENTS PRECISION MEASURING INSTRUMENTS SUBCOURSE OD1401 EDITION 9 Unites States Army Combined Arms Support Command Fort Lee, VA 23801-1809 5 CREDIT
Industrial Strength Rocket Launcher
Industrial Strength Rocket Launcher Description: Instructions for the construction of an industrial strength rocket launcher for use with paper rockets. Materials: Schedule 40 PVC piping and bushings from
Installation instruction CASAFLEX - Connecting piece DN 100
1 CASAFLEX - 11 10 114,3 x 4,5 3 5 2 4 1 7 6 8 12 9 Do not begin work until you have read the installation instruction carefully. 1 internal backing sleeve 2 graphite packing 3 connecting piece 4 thrust
F1 in Schools - 2015 World Finals Technical Regulations
2013 - F1 in Schools Ltd. Page 1 of 24 25 March 2015 Front Cover Colossus F1 2014 World Champions F1 Car, Robert May's School, Hampshire, England Amendments made on [Date] are indicated thus (using red
Why pigs get stuck and how to avoid it
Why pigs get stuck and how to avoid it Aidan O'Donoghue, Pipeline Research Limited, Glasgow, UK ( [email protected], www.pipeline-research.com ) Operators and contractors have been running
Technical Regulations 2015-2016
F1 in Schools - 2014 World Finals Technical Regulations Technical Regulations 2015-2016 2013 - F1 in Schools Ltd. Page 1 of 27 3 September 2015 CONTENTS PREFACE SUMMARY OF MAIN REVISIONS FROM 2013 REGULATIONS...
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
TEST REPORT Pipe-abc Line Inspection Project
TEST REPORT Pipe-abc Line Inspection Project Client YYYYYY / XX Facility Pipe-abc Cooling Spool Item Inspected General Pipe Inspection Method SLOFEC Date Commenced November 2007 Date Completed November
MASTER CYLINDER. Section 2. Master Cylinder. Tandem Master Cylinder. Master Cylinder
MASTER CYLINDER Master Cylinder The master cylinder converts the motion of the brake pedal into hydraulic pressure. It consists of the reservoir tank, which contains the brake fluid; and the piston and
SCOPE OF WORK AND TECHNICAL DETAILS
SCOPE OF WORK AND TECHNICAL DETAILS SCOPE OF WORK & TECHNICAL SPECIFICATION INTELLIGENT PIGGING Page 1 1.0 INTRODUCTION AND PROJECT SITE SCOPE OF WORK M/s GAIL (India) Limited is operating LPG pipeline
METHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
Inspections Standard Operating Procedure 5 Aboveground Storage Tanks
Aboveground Storage Tanks Aboveground Storage Tank Inspection This Standard Operating Procedure describes the steps that campus units that manage aboveground oil storage tanks (ASTs) or containers must
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
F1 in Schools - 2014 World Finals Technical Regulations. 2014 WORLD FINALS Technical Regulations
2014 WORLD FINALS Technical Regulations Refer also to the 2014 World Finals Competition Regulations. For World Finals use only. 2013 - F1 in Schools Ltd. Page 1 of 23 13 August 2014 Front Cover A1 Racing
necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the
Chapter 7 PLUMBING AND ELECTRICAL 7.1 Introduction to Plumbing and Electrical Consideration of support services such as plumbing and electrical systems from the preliminary schematics phase through final
Guidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
Water Transmission & Sewer Force Main Renewal 16 through 60
Water Transmission & Sewer Force Main Renewal 16 through 60 North American Operations 1973 S 91 st Street Milwaukee WI 53227 4700 N Pearl Street Jacksonville FL 32206 office 414.321.2247 fax 414.321.2297
Subject: Pre-Formed and Pre-Flared Hydraulic Brake Pipe Kits Now Available for Service
Subject: Pre-Formed and Pre-Flared Hydraulic Brake Pipe its Now Available for Service Models: 2000-2006 adillac Escalade Models 2000-2006 hevrolet Avalanche, Suburban, Tahoe 1999-2007 hevrolet Silverado
EH-20 20m antenna. By VE3RGW
EH-20 20m antenna By VE3RGW Equivalent circuit of EH-20 (prototype 2A) antenna system. Upper cylinder Lower cylinder Ground Counter pose Phasing coil Impedance transformer and tune circuit Tune coil Feed
Pole Lathe and Shave Horse Design
Pole Lathe and Shave Horse Design These pictures and accompanying words are Copyright Michael Hughes February 2002. They are not to be re-produced, in part or whole, without permission from the author.
PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790
PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790 Safety Disclaimer Only trained and responsible personnel should
The Engineering Science of Oil Pipelines
The Engineering Science of Oil Pipelines From the Keystone XL pipeline project to spills and leaks in existing lines, pipelines are in the news. The SMCC has prepared this backgrounder on crude oil and
F1 in Schools - 2015 World Finals Technical Regulations. Formula 1 Class
F1 in Schools - 2015 World Finals Technical Regulations Formula 1 Class 2013 - F1 in Schools Ltd. Page 1 of 23 7 July 2015 Front Cover Colossus F1 2014 World Champions F1 Car, Robert May's School, Hampshire,
AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun
AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun American Solar Water Heating Systems The American solar thermal system is more than just a solar water heater - it s the
Puddle Flange. FRANK Puddle Flange
Puddle Flange FRANK Puddle Flange The problem Problems keep on occurring when connecting pipes during construction work. Pipes laid in the ground must be introduced into concrete walls or shafts. In many
Milling Chuck Features
Milling Chuck Features Since its first introduction into the industry in 1963, Nikken has sold over 2,000,000 worldwide and never stopped improving its original design. Featuring multi-roller bearings
Health Care for Pipelines From Cradle to Grave
Health Care for Pipelines From Cradle to Grave By Jim Costain, GE Inspection Technologies Assuring the mechanical integrity of piping systems, whether they be in exploration, transmission, or process plants
June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL
7.0 7.1 GENERAL For the purpose of this manual, culverts are defined as structures that are completely surrounded by soil and located below the surface of the roadway parallel to the general direction
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html TECHNICAL SERVICE DEPARTMENT Removal, Cleaning, & Reinstallation of the Burner Assembly For models 74 & GT199 Required tools -
AAF Manufacturing Services. Leading the way in engineering excellence
AAF Manufacturing Services Leading the way in engineering excellence Contents Introduction Parts Manufacture Weld Assembly Surface Protection Mechanical & Electrical Final Assembly service agreements Introduction
HOBBING MACHINE TYPE ZFWZ 8000x40
Inventory number 416/635 Year of production 1973 Serial number 7160 HOBBING MACHINE TYPE ZFWZ 8000x40 Application The machine is provided for milling cylindrical, helical and helix cogwheels. The tooth
Challenges Managing ILI Data in an Enterprise Environment using PODS 6.0 Relational. Bruce Dupuis John Spurlock Alejandro Reyes
Challenges Managing ILI Data in an Enterprise Environment using PODS 6.0 Relational Bruce Dupuis John Spurlock Alejandro Reyes Triggers Partnership between TransCanada and ROSEN to implement a PIMS ILI
F O R E R U N N E R 6 1 0. q u i c k s t a r t m a n u a l
F O R E R U N N E R 6 1 0 q u i c k s t a r t m a n u a l Important Information warning Always consult your physician before you begin or modify any exercise program. See the Important Safety and Product
Installation Instructions
Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email [email protected] Phone:
Written By: Sam Lionheart
iphone 5s Battery Replacement Replace the battery in your iphone 5s. Written By: Sam Lionheart INTRODUCTION Use this guide to bring life back to your iphone 5s with a new battery. Removing the battery
1.2 For piping systems that operate at hoop stress of 20% or more of the Specified Minimum Yield Strength the following shall apply.
1.0 JOINT FIT-UP AND ALIGNMENT 1.1 For piping systems that operate at hoop stress of less than 20% and the internal adjoining ends do not vary more than 1 / 8 in. and adequate penetration and fusion can
$117.99 $31.99 $39.99 $23.99. Things to consider when buying your next socket set:
D004006 47 Piece 6 Point Standard/Deep SAE/Metric Socket Set SAE Standard: 3/16"-9/16" SAE Deep: 3/16"-9/16" Metric Standard: 4-14 mm Metric Deep: 4-12 mm 2", 6" Extensions Hand Driver U-Joint 45 Tooth
16 April 2012 1032011-F 1994-2002 Dodge Adjustable Track bar with Relocation Bracket 1
16 April 2012 1032011-F 1994-2002 Dodge Adjustable Track bar with Relocation Bracket 1 BD Adjustable Track Bar w/bracket Dodge 2500-3500 4WD Models 1994-2002 Dodge 1500 4WD Model 1994-2001 P/N# 1032011-F
Internal Strap Assemblies (Box Vehicles)
Commercial Body Fittings LOAD Internal Strap Assemblies (Box Vehicles) Part No. Working Buckle Webbing End Fitting Wgt. (kg) Length (mtr) CARG3309B 2.75 Overcentre 50mm Hook/Hook 0.59 CARG3312B 3.66 Overcentre
Corrosion protection linings. Issue 1
Corrosion protection linings Issue 1 Introduction While Humes sewerage pipes and products are designed to serve over 100 years in accordance with AS/NZS 4058, we offer corrosion protection linings to increase
DTU Animal Cart Programme
DTU Animal Cart Programme TECHNICAL 21 RELEASE PIPE AND ROLLER DONKEY CART AXLES Development Technology Unit, Department of Engineering, University of Warwick, Coventry, CV4 7AL UK, tel: +44 (0)1203 523523
Guidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D.
OSNA -10 Copper-Nickel Lined Pipes Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D. KME Germany AG & Co. KG Copper-Nickel Lined Pipes [GB] Member of the KME Group
Part and tooling design. Eastman Tritan copolyester
Part and tooling design Eastman Tritan copolyester Part and tooling design Process Part design Tooling design High cavitation considerations Process Process Project development flow chart Concept OEM generates
MEASURING WHEEL ALIGNMENT
MEASURING WHEEL ALIGNMENT 2003-04 WHEEL ALIGNMENT Specifications & Procedures - Hummer - H2 Steering and vibration complaints are not always the result of improper alignment. One possible cause is wheel
Auto-belay Cable Replacement Process
Auto-belay Cable Replacement Process Version 2.00 WARNING: The air pressure in the auto-belay system is what causes the cable to be retracted when releasing the cable or climbing the wall with the cable
StackFlowMaster FPD580 TORBAR probe Stack gas metering systems. Measurement made easy. Introduction. For more information
Commissioning instructions CI/FPD580/A EN StackFlowMaster FPD580 TORBAR probe Stack gas metering systems Measurement made easy Introduction This publication provides commissioning instructions for the
ECOplus Solar Cylinder
TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes
Butt Fusion Welding of HDPE Pipes Work Procedure
Butt Fusion Welding of HDPE Pipes Work Procedure A pipeline is as good as its weakest point. Accordingly it is not only important that quality pipes and components are used in a piping system, but also
INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM
INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM 1. IS 15663(Part 1):2006 This code covers requirements and recommendations for the design, materials, construction and testing of pipelines made of steel
ARVINMERITOR UNITIZED FRONT WHEEL HUB INSPECTION AND MAINTENANCE
SERVICE BULLETIN (Also applies to Mack Trucks Australia) NUMBER: SB-423-002 DATE: 8/23/02 MODEL: All with FF981 Front Axle ARVINMERITOR UNITIZED FRONT WHEEL HUB INSPECTION AND MAINTENANCE The ArvinMeritor
ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013
ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 0 QUALITY 0 YEAR GUARANTEE Exclusively distributed by: Table of contents Panel radiators General / Guarantee Technical data and radiator dimensions
INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!
In-situ Testing! Insitu Testing! Insitu testing is used for two reasons:! To allow the determination of shear strength or penetration resistance or permeability of soils that would be difficult or impossible
Air Conditioner Duct Construction & Repair
PROPER ROOF AIR CONDITIONER MOUNTING At Newmar, there are two different models of air conditioners available on all towable and motorized units. The different models are the Dometic Brisk and Penguin models,
HYBRID PETROLEUM INSTITUTE. Furnaces and Heaters Reliability and Asset Integrity Solutions
HYBRID PETROLEUM INSTITUTE We provide technology solutions for inspections and assessments of high accuracy, which support to process companies, transport and power generation to increase its usefulness,
www.the Floor Heating Warehouse.co.uk
www.the Floor Heating Warehouse.co.uk Underfloor Heating Installation Guide (Grundfoss Pump System) General Overview: Our water based underfloor heating system can be installed by your own plumber or heating