vacon nxi inverters fi4-fi8 user manual

Size: px
Start display at page:

Download "vacon nxi inverters fi4-fi8 user manual"

Transcription

1 vacon nxi inverters fi4-fi8 user manual

2

3 AT LEAST THE 10 FOLLOWING STEPS OF THE START-UP QUICK GUIDE MUST BE PERFORMED DURING THE INSTALLATION AND COMMISSIONING. IF ANY PROBLEMS OCCUR, PLEASE CONTACT YOUR LOCAL DISTRIBUTOR. Start-up Quick Guide 1. Check that the delivery corresponds to your order, see Chapter Before taking any commissioning actions, read carefully the safety instructions in Chapter Before the mechanical installation, check the minimum clearances around the unit and check the ambient conditions in Chapter Check the size of the motor cable, DC supply cable, and mains fuses, and check the cable connections. Read Chapters Follow the installation instructions, see Chapter The sizes and earthing of control connections are explained in Chapter If the Start-Up wizard is active, select the language you want the keypad and the application to use and confirm by pressing the enter button. If the Start-Up wizard is not active, follow the instructions in 7a and 7b below. 7a. Select the language of the keypad from Menu M6, page 6.1. Instructions on using the keypad are given in Chapter 7. 7b. Select the application you want to use from Menu M6, page 6.2. Instructions on using the keypad are given in Chapter All parameters have factory default values. To ensure proper operation, check the rating plate data for the values below and the corresponding parameters of parameter group G2.1. nominal voltage of the motor nominal frequency of the motor nominal speed of the motor nominal current of the motor motor cos All parameters are explained in the All in One Application Manual. 9. Follow the commissioning instructions, see Chapter The Vacon NX Inverter is now ready for use. Vacon Plc is not responsible for the use of the inverters against the instructions.

4 CONTENTS VACON NXI USER S MANUAL INDEX 1 SAFETY 2 EU DIRECTIVE 3 RECEIPT OF DELIVERY 4 TECHNICAL DATA 5 INSTALLATION 6 CABLING AND CONNECTIONS 7 CONTROL KEYPAD 8 COMMISSIONING 9 FAULT TRACING

5 vacon 3 ABOUT THE VACON NXI USER'S MANUAL AND THE All in One APPLICATION MANUAL Congratulations for choosing Vacon NX Inverters! The User's Manual will provide you with the necessary information about the installation, commissioning and operation of Vacon NX Inverters. We recommend that you carefully study these instructions before powering up the inverter for the first time. In the All in One Application Manual you will find information about the different applications included in the All in One Application Package. Should these applications not meet the requirements of your process, please contact the manufacturer for information on special applications. This manual is available in both paper and electronic editions. We recommend you to use the electronic version if possible. If you have the electronic version at your disposal, you will be able to benefit from the following features: The manual contains several links and cross-references to other locations in the manual, which makes it easier to move around in the manual. The reader can thus easily find and check things. The manual also contains hyperlinks to web pages. To visit these web pages through the links, you must have an internet browser installed on your computer. Päivystys: vacon@vacon.com

6 4 vacon Vacon NX User's Manual Document code: DPD00908A Date: Index 1. SAFETY Warnings Safety instructions Earthing and earth fault protection Running the motor EU DIRECTIVE CE marking EMC directive Introduction Technical criteria Vacon inverter EMC classification RECEIPT OF DELIVERY Type designation code FR4 FR The standard features of NX inverters Storage Maintenance Warranty TECHNICAL DATA Introduction Power ratings Vacon NXI_xxxx 5 Supply voltage Vdc, Motor voltage Vac Vacon NXI_xxxx 6 Supply voltage Vdc, Motor voltage Vac Technical information INSTALLATION Mounting Fan cooling Frames FR4 to FR Power losses as function of switching frequency CABLING AND CONNECTIONS Power unit Power connections DC supply and motor cables Control cable Fuses, NXI_xxxx Fuses, NXI_xxxx Cable sizes, NXI_xxxx Cable sizes, NXI_xxxx Puhelin: Fax:

7 vacon Installation instructions Stripping lengths of motor and DC supply cables Vacon NX frames Cable installation and the UL standards Cable and motor insulation checks Control unit Control connections Control cables Galvanic isolation barriers Control terminal signals Digital input signal inversions Jumper selections on the NXOPTA1 basic board CONTROL KEYPAD Indicators on the keypad display Drive status indications Control place indicators Status LEDs (green green red) Text lines Keypad push-buttons Button descriptions Navigation on the control keypad Monitoring menu (M1) Parameter menu (M2) Keypad control menu (M3) Selection of control place Keypad reference Keypad direction Stop button activated Active faults menu (M4) Fault types Fault codes Fault time data record Fault history menu (M5) System menu (M6) Selection of language Application selection Copy parameters Parameter comparison Safety Keypad settings Hardware settings System info Expander board menu (M7) Further keypad functions COMMISSIONING Safety Päivystys: vacon@vacon.com

8 6 vacon 8.2 Commissioning the inverter FAULT TRACING Puhelin: Fax:

9 SAFETY vacon 7 1. SAFETY ONLY A COMPETENT ELECTRICIAN MAY CARRY OUT THE ELECTRICAL INSTALLATION 1.1 Warnings WARNING The components of the power unit of the inverter are live when the Vacon NX is connected to DC supply. Coming into contact with this voltage is extremely dangerous and may cause death or severe injury. The control unit is isolated from mains potential. The supply and motor terminals are live when the Vacon NX is connected to DC supply, even if the motor is not running. The control I/O-terminals are isolated from the mains potential. However, the relay outputs and other I/O-terminals may have dangerous control voltage present even when the Vacon NX is disconnected from the DC supply.. The inverter has a large capacitive leakage current. If the inverter is used as a part of a machine, the machine manufacturer is responsible for providing the machine with a main switch (EN ). Only spare parts delivered by Vacon can be used. 1.2 Safety instructions The Vacon NX inverter is meant for fixed installations only. Do not perform any measurements when the inverter is connected to the DC supply. After having disconnected the inverter from the DC supply, wait until the fan stops and the indicators on the keypad go out (if no keypad is attached see the indicator through the keypad base). Wait 5 more minutes before doing any work on Vacon NX connections. Do not even open the cover before this time has expired. Do not perform any voltage withstand tests on any part of Vacon NX. There is a certain procedure according to which the tests shall be performed. Ignoring this procedure may result in damaged product. Prior to measurements on the motor or the motor cable, disconnect the motor cable from the inverter. Do not touch the components on the circuit boards. Static voltage discharge may damage the components. Before connecting the inverter to DC supply, make sure that the Vacon NX front and cable covers are closed. Päivystys: vacon@vacon.com 1

10 8 vacon SAFETY 1.3 Earthing and earth fault protection The Vacon NX inverter must always be earthed with an earthing conductor connected to the earthing terminal. The earth fault protection inside the inverter only protects the inverter against earth faults in the motor or the motor cable. Due to the high capacitive currents present in the inverter, fault current protective switches may not function properly. If fault current protective switches are used, they need to be tested with earth fault currents present during possible fault situations. 1.4 Running the motor Warning symbols For your own safety, please pay special attention to the instructions marked with the following symbols: = Dangerous voltage WARNING HOT SURFACE = General warning = Hot surface Risk of burn MOTOR RUN CHECK LIST WARNING Before starting the motor, check that the motor is mounted properly and ensure that the machine connected to the motor allows the motor to be started. Set the maximum motor speed (frequency) according to the motor and the machine connected to it. Before reversing the motor, make sure that this can be done safely. Make sure that no power correction capacitors are connected to the motor cable. Make sure that the motor terminals are not connected to mains potential. 1 Puhelin: Fax:

11 Turvallisuus vacon 9 2. EU DIRECTIVE 2.1 CE marking The CE marking on the product guarantees the free movement of the product within the EEA (European Economic Area). It also guarantees that the product complies with applicable directives (for example, the EMC directive and other possible so-called new method directives). Vacon NX inverters carry the CE label as a proof of compliance with the Low Voltage Directive (LVD) and the Electro Magnetic Compatibility (EMC) directive. SGS FIMKO has acted as the Competent Body. 2.2 EMC directive Introduction The EMC Directive provides that the electrical apparatus must not excessively disturb the environment it is used in, and, on the other hand, it shall have an adequate level of immunity toward other disturbances from the same environment. The compliance of Vacon NX inverters with the EMC directive is verified with Technical Construction Files (TCF) and checked and approved by SGS FIMKO, which is a Competent Body. The Technical Construction Files are used to authenticate the conformity of Vacon inverters with the Directive because it is impossible to test such a large product family in a laboratory environment and because the combinations of installation vary greatly Technical criteria Our basic idea was to develop a range of inverters offering the best possible usability and costefficiency. EMC compliance was a major consideration from the outset of the design. Vacon NX inverters are marketed throughout the world, a fact which makes the EMC requirements of customers different. As far as immunity is concerned, all Vacon NX inverters are designed to fulfil even the strictest requirements Vacon inverter EMC classification Factory delivered Vacon NX inverters are Class T equipment, which fulfil all EMC immunity requirements (standards EN , and EN ). Class T: Class T equipment have a small earth leakage current and can be used with floating DC input. If they are used with other supplies, no EMC requirements are complied with. Warning: This product is of the restricted sales distribution class according to IEC In residential areas, this product may cause radio interference in which case the user may be required to take adequate measures. Vacon Oyj Puhelin: Fax: Päivystys: vacon@vacon.com

12 10 vacon receipt of delivery 3. RECEIPT OF DELIVERY Vacon NX inverters have undergone scrupulous tests and quality checks at the factory before they are delivered to the customer. However, after unpacking the product, check that no signs of transportation damage is to be found on the product and that the delivery is complete (compare the type designation of the product to the code below, see Figure 3-1 Should the drive have been damaged during the shipping, please contact primarily the cargo insurance company or the carrier. If the delivery does not correspond to your order, contact the supplier immediately. 3.1 Type designation code FR4 FR8 NX I Nominal mains voltage: 5 = VDC, 6 = VDC Nominal current esim = 4 A, 0022 = 22 A Reserved for cooling method, now always air cooling: _ = air cooling (= no symbol) W = liquid cooling Code: I = Inverter Unit (INU) Product series: NX Figure 3-1 Vacon NX type designation code, FR4 FR8 nxik2.fh8 3 Tel: Fax:

13 receipt of delivery vacon The standard features of NX inverters INU Sales code NXI_AAAA 5/6 Standard features DC connection FR4, FR6 and FR7 IP21 Air cooling Integrated charging Alphanumeric control panel (in the front of the module) I/O modules A1 & A2 Standard board Safety CE / UL Sales code NXI_AAAA 5/6 Standard features FR8 DC connection IP00 Air cooling Integrated charging Alphanumeric control panel (in the front of the module) I/O modules A1 & A2 Standard board Safety CE / UL Table 3-1. The standard features of NX inverters 24-hour support: +358-(0) vacon@vacon.com 3

14 12 vacon receipt of delivery 3.2 Storage If the inverter is to be stored before use, make sure that the ambient conditions are acceptable: Storage temperature C Relative humidity <95%, no condensation If the inverter is stored for over 12 months, contact Vacon service before connecting the inverter to the power supply. 3.3 Maintenance In normal conditions, Vacon NX inverters are maintenance-free. However, we recommend to clean the heatsink with compressed air whenever necessary. The cooling fan can easily be changed if necessary. It may also be necessary to check the tightening torques of terminals at certain intervals. 3.4 Warranty Only manufacturing defects are covered by the warranty. The manufacturer assumes no responsibility for damages caused during or resulting from transport, receipt of the delivery, installation, commissioning or use. The manufacturer shall in no event and under no circumstances be held responsible for damages and failures resulting from misuse, wrong installation, unacceptable ambient temperature, dust, corrosive substances or operation outside the rated specifications. Neither can the manufacturer be held responsible for consequential damages. The Manufacturer's warranty period is 18 months from the delivery or 12 months from the commissioning whichever expires first (General delivery terms NL92/Orgalime S92). The local distributor may grant a warranty time different from the above. This warranty time shall be specified in the distributor's sales and warranty terms. Vacon assumes no responsibility for any other warranties than that granted by Vacon itself. In all matters concerning the warranty, please contact your distributor first. 3 Tel: Fax:

15 technical data vacon TECHNICAL DATA 4.1 Introduction The figure below presents the block diagram of the Vacon NX inverter. The inverter mechanically consists of two units, the Power Unit and the Control Unit. The Power Unit contains an inverter bridge which consists of IGBT switches and produces a symmetrical, 3-phase PWM-modulated AC voltage to the motor. To protect the DC-link capacitors, the Power Unit also contains a charging circuit for controlled DC-link charge. Use the B+ and DCterminals in order to bypass the charging circuit. The Motor and Application Control Block is based on microprocessor software. The microprocessor controls the motor based on the information it receives through measurements, parameter settings, control I/O and control keypad. The motor and application control block controls the motor control ASIC which, in turn, calculates the IGBT positions. Gate drivers amplify these signals for driving the IGBT inverter bridge. Power module Mains B + D C+ D C- Integrated charging circuit Charg.res. IGBT Inverter Current Sensors = 3~ Motor U V W Output EMCfilter Fan Power Supply Measurements Gate Drivers Control Keypad Control module Motor and Application Control Motor Control ASIC Control I/O Control I/O Control I/O Control I/O Control I/O Figure 4-1. The block diagram of Vacon NX inverter 24-hour support: +358-(0) vacon@vacon.com 4

16 14 vacon technical data The control keypad constitutes a link between the user and the inverter. The control keypad is used for parameter setting, reading status data and giving control commands. It is detachable and can be operated externally and is connected via a cable to the inverter. Instead of the control keypad, a PC can be used to control the inverter if connected through a similar cable (VACON RS232PC 1.5M). The basic control interface and the parameters (the Basic Application) are easy to use. If a more versatile interface or parameters are required, a more suitable application can be chosen from the "All in One+" Application Package. See the "All in One+" Application Manual for more information on the different applications. Optional I/O expander boards that increase the number of inputs and outputs to be used are also available. For more information, contact the Manufacturer or your local distributor (see back cover). 4 Tel: Fax:

17 technical data vacon Power ratings Vacon NXI_xxxx 5 Supply voltage Vdc, Motor voltage Vac High overload = Max current IS, 2 sec/20 sec, 150% overloadability, 1 min/10 min Following continuous operation at rated output current, 150 % rated output current (IH) for 1 min, followed by a period of load current less than rated current, and of such duration that the r.m.s output current, over the duty cycle, does not exceed rated output current (IH) Low overload = Max current IS, 2 sec/20 sec, 110% overloadability, 1 min/10 min Following continuous operation at rated output current, 110% rated output current (IL) for 1 min, followed by a period of load current less than rated current, and of such duration that the r.m.s output current, over the duty cycle, does not exceed rated output current (IL) Frames FR4 7 are available as IP21 and FR8 as IP 00 Motor voltage Vac, 50/60 Hz, 3~ Inverter type Rated continuo us current I L (A) Loadability Motor shaft power Low High 513Vdc supply 675Vdc supply 10% overload current (A) Rated continuou s current I H (A) 50% overload current (A) Max current I S 10% overload 40 C P(kW) 50% overload 50 C P(kW) 10% overload 40 C P(kW) 50% overload 50 C P(kW) Frame NXI _ FR4 128x292x190/5 NXI _ FR4 128x292x190/5 NXI _ FR4 128x292x190/5 NXI _ FR6 195x519x237/16 NXI _ FR6 195x519x237/16 NXI _ FR6 195x519x237/16 NXI _ FR6 195x519x237/16 NXI _ FR6 195x519x237/16 NXI _ FR7 237x591x257/29 NXI _ FR7 237x591x257/29 NXI _ FR7 237x591x257/29 NXI _ FR7 237x591x257/29 NXI _ FR8 285x721x288/48 Table 4-1. Power ratings and dimensions of Vacon NX, supply voltage Vdc Note: The rated currents in given ambient temperatures are achieved only when the switching frequency is equal to or less than the factory default. Dimensions and weight WxHxD/kg 24-hour support: +358-(0) vacon@vacon.com 4

18 16 vacon technical data Vacon NXI_xxxx 6 Supply voltage Vdc, Motor voltage Vac High overload = Max current IS, 2 sec/20 sec, 150% overloadability, 1 min/10 min Following continuous operation at rated output current, 150 % rated output current (IH) for 1 min, followed by a period of load current less than rated current, and of such duration that the r.m.s output current, over the duty cycle, does not exceed rated output current (IH) Low overload = Max current IS, 2 sec/20 sec, 110% overloadability, 1 min/10 min Following continuous operation at rated output current, 110% rated output current (IL) for 1 min, followed by a period of load current less than rated current, and of such duration that the r.m.s output current, over the duty cycle, does not exceed rated output current (IL) Frames FR4 7 are available as IP21 and FR8 as IP 00 Motor voltage Vac, 50/60 Hz, 3~ Inverter type Rated continuous current I L (A) Loadability Motor shaft power Low High 930Vdc supply 10% overload current (A) Rated continuou s current I H (A) 50% overload current (A) Max current I S 10% overload 40 C P(kW) 50% overload 50 C P(kW) Frame Dimensions and weight WxHxD/kg NXI _ FR6 195x519x237/16 NXI _ FR6 195x519x237/16 NXI _ FR6 195x519x237/16 NXI _ FR6 195x519x237/16 NXI _ FR6 195x519x237/16 NXI _ FR6 195x519x237/16 NXI _ FR6 195x519x237/16 NXI _ FR6 195x519x237/16 NXI _ FR6 195x519x237/16 NXI _ FR7 237x591x257/29 NXI _ ,5 FR7 237x591x257/29 NXI _ FR8 285x721x288/48 NXI _ FR8 285x721x288/48 NXI _ FR8 285x721x288/48 Table 4-2. Power ratings and dimensions of Vacon NX, supply voltage Vdc Note: The rated currents in given ambient temperatures are achieved only when the switching frequency is equal to or less than the factory default. 4 Tel: Fax:

19 technical data vacon Technical information DC connection Input voltage U in Vdc; Vdc; 0% +0%, the ripple voltage of the inverter supply voltage generated during the rectification of the fundamental frequency AC voltage must be less than 50Vp-p. Connection to DC supply Once per minute or less (normal) Starting delay FR4 FR8: 2 s Motor connection Control characteristics Ambient conditions EMC (at default settings) Output voltage 3 ~ 0 - U in / 1.4 Continuous output current Starting torque Starting current Output frequency Frequency resolution Control method Switching frequency (see parameter 2.6.9) Frequency reference Analogue input Panel reference Field weakening point Acceleration time Deceleration time Ambient operating temperature Storage temperature Relative humidity Air quality: chemical vapours mechanical particles Altitude Vibration EN50178/EN Shock EN50178, EN Enclosure class Immunity I H : Ambient temperature max. +50 C, overload 1.5 x I H (1 min./10 min.) I L : Ambient temperature max. +40 C, overload 1.1 x I L (1 min./10 min.) I S for two seconds, depends on the motor I S for 2 s every 20 s Hz; 7200 Hz (special use) Depends on application Frequency control U/f Open Loop Sensorless Vector Control Closed Loop Frequency Control Closed Loop Vector Control NXI_xxxx 5: 1 16 khz; Factory default 10 khz NXI_0072 and greater: 1 10 khz; Factory default 3.6 khz NXI_xxxx 6: 1 6 khz; Factory default 1.5 khz Resolution 0.1% (10-bit), accuracy ±1% Resolution 0.01 Hz Hz sec sec 10 C (no frost) +50 C: I H (FR10: max. +40ºC) 10 C (no frost) +40 C: I L 40 C +70 C 0 to 95% RH, non-condensing, non-corrosive, no dripping water IEC , unit in operation, class 3C2 IEC , unit in operation, class 3S2 100% load capacity (no derating) up to 1,000 m 1-% derating for each 100m above 1000.; max. 3000m Hz Displacement amplitude 0,25 mm (peak) at Hz Max acceleration amplitude 1 G at Hz UPS Drop Test (for applicable UPS weights) Storage and shipping: max. 15 G, 11 ms (in package) FR4 7 IP21/NEMA1 standard FR8 IP 00 standard Fulfils all EMC standards 24-hour support: +358-(0) vacon@vacon.com 4

20 18 vacon technical data Safety Control connections Protections Analogue input voltage Analogue input current Digital inputs (6) Auxiliary voltage Output reference voltage Analogue output Digital outputs Relay outputs Overvoltage trip limit Undervoltage trip limit Earth fault protection Output phase supervision Overcurrent protection Unit overtemperature protection Motor overload protection Motor stall protection Motor underload protection Short-circuit protection of +24V and +10V reference voltages Table 4-3. Technical information EN (1997), EN (1996), EN (2000, 3 rd edition) (as relevant), CE, UL, CUL, FI, GOST R, IEC ; (see unit nameplate for more detailed approvals) 0 +10V, R i = 200k, ( 10V +10V joystick control) Resolution 0.1%, accuracy ±1% 0(4) 20 ma, R i = 250 differential Positive or negative logic; 18 30VDC +24V, ±15%, max. 250mA +10V, +3%, max. load 10mA 0(4) 20mA; R L max. 500 ; Resolution 10bit; Accuracy ±2% Open collector output, 50mA/48V 2 programmable change-over relay outputs Switching capacity 24VDC/8A, 250VAC/8A, 125VDC/0.4A Min.switching load: 5V/10mA NXI_5: 911VDC; NXI_6: 1200VDC NXI_5: 333VDC; NXI_6: 460 VDC In case of earth fault in motor or motor cable, only the inverter is protected Trips if any of the output phases is missing Yes Yes Yes Yes Yes Yes Structure Inom (output) Motor cos Idc (input) FR FR FR FR Table 4-4 DC currents of Vacon NX, supply voltage Vdc 4 Tel: Fax:

21 technical data vacon 19 Structure Inom (output) Motor cos Idc (input) FR6 4,5 0,81 4,7 5,5 0,82 5,9 7,5 0,83 8,1 10,0 0,84 10,9 13,5 0,85 14,9 18,0 0,85 19,9 22, 0,86 24,6 27,0 0,86 30,2 34,0 0,86 38,1 FR7 41,0 0, ,0 0,87 59 FR8 62,0 0, ,0 0, ,0 0, Table 4-5. DC currents of Vacon NX, supply voltage Vdc Structure NXI_xxxx 5 / F NXI_xxxx 6 / F FR FR FR FR FR Table 5-1. DC-link capacitance by structure. 24-hour support: +358-(0) vacon@vacon.com 4

22 20 vacon installation 5. INSTALLATION 5.1 Mounting The inverter can be mounted in either a vertical or horizontal position on a wall or on the back plane of a cubicle. Enough space must be reserved around the inverter to ensure sufficient cooling, see Figure 5-6. You must follow the minimum dimensions for installation, see Table 5-6 and Table 5-7. Also make sure that the mounting plane is relatively even. The inverter is fixed with four screws (or bolts, depending on the unit size). The dimensions for installation are presented in Figure 5-6 and Table 5-6. Lift units bigger than FR7 out of the package using a jib crane. Ask the factory or your local distributor for information on how to lift the unit safely. The following pages show the dimensions for Vacon NX with a default enclosure in Figure 5-1, and with flange mounting in Figures 5-2 and Figure 5-4. Dimensions for the opening needed in flange mounting are given in Table 5-3 and Table Tel: Fax:

23 installation vacon 21 Ø W2 D1 H1 H2 W1 H3 E1Ø E2Ø* Ø fr5ip21.fh8 Figure 5-1. The dimensions of Vacon NX, IP21 Type Dimensions [mm] W1 W2 H1 H2 H3 D1 E1 NXI_ x 28.3 NXI_ NXI_ x 37 NXI_ NXI_ x 47 NXI_ NXI_ x 59 Table 5-1. Dimensions for different inverter types, IP21 24-hour support: +358-(0) vacon@vacon.com 5

24 22 vacon installation W2 H4 D1 D2 H5 H1 H2 W1 H3 Ø fr5ip21kaulus.fh8 Figure 5-2. Vacon NX dimensions, IP21 with flange, FR4 and FR6 Type Dimensions [mm] W1 W2 H1 H2 H3 H4 H5 D1 D2 NXI_ NXI_ NXI_ Table 5-2. Dimensions for inverter types FR4 and FR6, IP21 with flange 5 Tel: Fax:

25 installation vacon 23 Ø H2 W3 W2 W1 H3 H1 fr6aukko.fh8 H4 Figure 5-3. The opening needed for flange mounting, FR4 and FR6 Type Dimensions [mm] W1 W2 W3 H1 H2 H3 H4 NXI_ NXI_ NXI_ Table 5-3. Dimensions for the opening for flange mounting, FR4 and FR6 24-hour support: +358-(0) vacon@vacon.com 5

26 24 vacon installation W4 W2 H7 H6 H4 D2 D1 H3 H1 H2 H4 W3 W1 H5 fr7kaulusip21.fh8 Figure 5-4. Vacon NX dimensions, IP21 with flange, FR4 and FR6 Type Dimensions [mm] W1 W2 W3 W4 H1 H2 H3 H4 H5 H6 H7 D1 D2 NXI_ NXI_ NXI_ NXI_ Table 5-4. Dimensions for inverter types FR7 and FR8, IP21 with flange 5 Tel: Fax:

27 installation vacon 25 H5 H2 H2 H3 H4 H1 H6 W1 W2 W3 Ø Figure 5-5. The opening needed for flange mounting, FR7/FR8 fr7aukko.fh8 Type Dimensions [mm] W1 W2 W3 H1 H2 H3 H4 H5 H6 NXI_ NXI_ NXI_ NXI_ Table 5-5. Dimensions for the opening for flange mounting, FR7/FR8 24-hour support: +358-(0) vacon@vacon.com 5

28 26 vacon installation 5.2 Fan cooling Frames FR4 to FR8 Enough free space must be left around the inverter to ensure sufficient air circulation and cooling. You will find the required dimensions for free space in the table below. If several units are mounted on top of each other, the required free space equals C + D (see figure below). Moreover, the outlet air used for cooling by the lower unit must be directed away from the air intake of the upper unit. When planning the cooling for the space, take into consideration that the inverter s heat loss is 2.5% of the nominal capacity. Type Dimensions [mm] A A 2 B C D NXI_ NXI_ NXI_ NXI_ NXI_ NXI_01405 NXI_ Table 5-6. Mounting space dimensions A = clearance around the inverter (see also A 2 and B) A 2 = clearance needed on either side of the inverter for fan change (without disconneting the motor cables) ** = min. clearance for fan change B = distance from one inverter to another or distance to cabinet wall C = free space above the inverter D = free space underneath the inverter C B A A A 2 A 2 D Figure 5-6. Installation space NK5_2 B Type Greatest possible heat loss (kw) Cooling air required [m 3 /h) NXI_ ,2 70 NXI_ NXI_ ,75 NXI_ NXI_ NXI_01405 NXI_ Table 5-7. Required cooling air 1,9 1,2 3,3 2, Tel: Fax:

29 installation vacon Power losses as function of switching frequency Raising the switching frequency of the drive, to reduce motor noise for example, inevitably affects the power losses and cooling requirements as shown in the Figure below. It illustrates the power loss FR7 as function of switching frequency. For more information, contact the Manufacturer or your local distributor (see back cover). Figure 5-7. Power loss as a function of switching frequency; NXI hour support: +358-(0) vacon@vacon.com 5

30 28 vacon cabling and connections 6. CABLING AND CONNECTIONS 6.1 Power unit The following wiring diagrams show the supply and motor connections. B+ DC+ DC- B+ B- PE U V W M Figure 6-1. The basic wiring diagram 6 Tel: Fax:

31 cabling and connections vacon Power connections DC supply and motor cables The power cables are connected to terminals DC+ and DC- (R+/B+ and DC terminals when using an external charging circuit) and the motor cables to terminals U, V and W. A cable entry gland should be used at the motor cable end to reach the EMC levels, see Table 6-1. Use cables with a heat resistance of at least +60C. The cables and the fuses must be sized according to the inverter nominal output current which you can find on the rating plate. Installation of cables according to UL regulations is presented in Chapter and ar fuse sizes in Tables 6-2 and 6-3. The minimum dimensions of the Cu-cables are shown in Table 6-4. If the motor temperature protection of the drive (see Vacon All in One Application Manual) is used as an overload protection, the cable shall be chosen accordingly. If three or more cables are used in parallel for bigger units, each cable requires a separate overload protection. These instructions apply only to installations with one motor and one cable connection from the inverter to the motor. In any other case, ask the factory for more information. Cable type Supply cable Motor cable Control cable Level T Power cable intended for fixed installation and the specific DC voltage. Shielded cable not required. (NKCABLES/MCMK or similar recommended) Power cable equipped with concentric protection wire and intended for the specific mains voltage. (NKCABLES/MCMK or similar recommended). Screened cable equipped with compact low-impedance shield (NKCABLES/jamak, SAB/ÖZCuY-O or similar). Table 6-1. Cable types required to meet standards Control cable For information on control cables, see Chapter and Table hour support: +358-(0) vacon@vacon.com 6

32 30 vacon cabling and connections Fuses, NXI_xxxx 5 Frame Type I L [A] Bussman ar fuse type Fuse size Fuse U n [V] Fuse I n [A] No. of fuses FR4 NXI_ M FR4 NXI_ M FR4 NXI_ M FR6 NXI_ M FR6 NXI_ M FR6 NXI_ M FR6 NXI_ M FR6 NXI_ M FR7 NXI_ M FR7 NXI_ M FR7 NXI_ M FR7 NXI_ M FR8 NXI_ M Table 6-2. Fuses used in Vacon NX ( V) Fuses, NXI_xxxx 6 Frame Type I L [A] Bussman ar fuse type Fuse size Fuse U n [V] Fuse I n [A] No. of fuses FR6 NXI_ M FR6 NXI_ M FR6 NXI_ M FR6 NXI_ M FR6 NXI_ M FR6 NXI_ M FR6 NXI_ M FR6 NXI_ M FR6 NXI_ M FR7 NXI_ M FR7 NXI_ M FR8 NXI_ M4200 1SHT FR8 NXI_ M4200 1SHT FR8 NXI_ M4200 1SHT Table 6-3. Fuses used in Vacon NX ( V) Information about fuses ar fuses protect the cables of the device against short-circuits. gr fuses are designed to protect the device against both overcurrent and short-circuits. gg fuses are generally used to protect cables against overcurrent and short-circuits. 6 Tel: Fax:

33 cabling and connections vacon Cable sizes, NXI_xxxx 5 Frame Type Supply Terminal cable size I L Motor cable Earth cable [A] Cu [mm 2 Main terminal ] Cu [mm 2 terminal ] [mm 2 ] [mm 2 ] FR4 NXI_ *1.5 3* NXI_ *2.5 3* FR Cu NXI_ *10 3* Al FR Cu NXI_ *16 3* Al NXI_ *25 3* Cu 6 50 Al 6 70 NXI_ *35 3* Cu 6 50 Al 6 70 NXI_ *50 3* Cu 6 50 Al 6 70 FR8 NXI_ *70 3* Cu/Al Table 6-4. Cable sizes for Vacon NX_ Cable sizes, NXI_xxxx 6 Frame FR6 FR7 Type I L [A] Supply cable Cu [mm 2 ] Motor cable Cu [mm 2 ] NXI_ *2.5 3* NXI_ *2.5 3* NXI_ *4 3*4+4 NXI_ *6 3*6+6 NXI_ *10 3*10+10 NXI_ *100 3*10+10 NXI_ *16 3*16+16 FR8 NXI_ *25 3*25+16 NXI_ *35 3*35+16 Table 6-5. Cable sizes for Vacon NX_6 Terminal cable size Main terminal [mm 2 ] Cu 6 50 Al Cu 6 50 Al Cu 6 50 Al Cu 6 50 Al Cu 6 50 Al Cu 6 50 Al Cu 6 50 Al Earth terminal [mm 2 ] Cu/Al hour support: +358-(0) vacon@vacon.com 6

34 32 vacon cabling and connections Installation instructions Before starting the installation, check that none of the components of the inverter are live. If the inverter is installed outside the cubicle, cabinet or device space, you need to install a separate inverter cover (see, for example Figure 6-3 ) in accordance with protection class IP21 requirements. There is no need to install the inverter cover if the inverter is installed in a cubicle, separate cabinet or device space. Place the motor cables sufficiently far from other cables: Avoid placing the motor cables in long parallel lines with other cables If the motor cables runs in parallel with other cables, note the minimum distances between the motor cables and other cables given in the table below. The given distances also apply between the motor cables and signal cables of other systems. The maximum length of the motor cables is 300 m (units with power greater than 1.5 kw) and 100 m (units with power from 0.75 to 1.5 kw). The motor cables should cross other cables at an angle of 90 degrees. 4 If cable insulation checks are needed, see Chapter. 6 Tel: Fax:

35 cabling and connections vacon 33 5 Connect the cables: Strip the motor and DC supply cables as advised in Figure 6-2 and Table 6-6. Remove the screws of the cable protection plate. Do not open the cover of the power unit! Make holes into and pass the cables through the rubber grommets on the bottom of the power unit. The rubber grommets are delivered in a separate bag. Connect the DC supply, motor and control cables into their respective terminals. For information on the installation of greater units, please contact the factory or your local distributor. For Information on cable installation according to UL regulations, see Chapter For information on cable installation according to EMC regulations, see Chapter Make sure that the control cable wires do not come in contact with the electronic components of the unit. If an external brake resistor (optional) is used, connect its cable to the appropriate terminal. Check the connection of the earth cable to the motor and the inverter terminals marked with. Connect the separate shield of the power cable to the earth terminals of the inverter, motor and the supply centre. Attach the cable protection plate with the screws. Ensure that the control cables or the cables of the unit are not trapped between the frame and the protection plate. 24-hour support: +358-(0) vacon@vacon.com 6

36 34 vacon cabling and connections Stripping lengths of motor and DC supply cables Earth conductor C1 A2 C2 D1 B2 D2 Figure 6-2. Stripping of cables nk6141.fh8 Frame size C1 D1 A2 B2 C2 D2 FR / FR / FR / FR Table 6-6. Cable stripping lengths [mm] 6 Tel: Fax:

37 cabling and connections vacon Vacon NX frames Figure 6-3. Vacon NXI, FR4 Figure 6-4. Vacon NXI, FR6, protection class IP21 24-hour support: +358-(0)

38 36 vacon cabling and connections Figure 6-5. Vacon NXI, FR7. Protection class IP21 Figure 6-6. Vacon NXI, FR8. Protection class IP00 6 Tel: Fax:

39 cabling and connections vacon Cable installation and the UL standards To meet the UL (Underwriters Laboratories) regulations, a UL-approved copper cable with a minimum heat-resistance of +60/75 C must be used. The tightening torques of the terminals are given below in Table 6-7. Type Frame Tightening torque [Nm] NXI_ FR NXI_ NXI_ FR6 10 NXI_ NXI_ FR7 10 NXI_ NXI_ FR8 20/9* Table 6-7. Tightening torques of terminals * Tightening torque of terminal connection to the isolative base in Nm Cable and motor insulation checks 1. Motor cable insulation checks Disconnect the motor cable from terminals U, V, and W of the inverter and from the motor. Measure the insulation resistance of the motor cable between each phase conductor as well as between each phase conductor and the protective ground conductor. The insulation resistance must be >1M. 2. DC supply cable insulation checks Disconnect the DC supply cable from terminals B- and B+ of the inverter and from DC supply. Measure the insulation resistance between each conductor and ground. The insulation resistance must be >1M. 3. Motor insulation checks Disconnect the motor cable from the motor and open the bridging connections in the motor connection box. Measure the insulation resistance of each motor winding. The measurement voltage must equal at least the motor nominal voltage but not exceed 1,000 V. The insulation resistance must be >1M. 24-hour support: +358-(0) vacon@vacon.com 6

40 38 vacon cabling and connections 6.2 Control unit The control unit of the inverter consists of the control board and option boards (see Figure 6-7 and Figure 6-20) connected to the five slot connectors (A to E) on the control board. The control board is connected to the power unit through a D connector (1). A B C D E Figure 6-7. control board Figure 6-8. Basic and option board connections on the control board When the inverter is delivered from the factory, the control unit usually includes two basic boards (I/O board and relay board), which are normally installed in slots A and B. On the next pages you will find the arrangement of the control I/O and the relay terminals of the two basic boards, the general wiring diagram and the control signal descriptions. The I/O boards mounted at the factory are indicated in the type code. For more information on the option boards, see Vacon NX option board manual (ud741). The control board can be powered externally (+24V) by connecting the external power source to bidirectional terminal #6 (see Table 6-9). This voltage is sufficient for parameter setting and for keeping the fieldbus active. Note! If the +24V input of several inverters are connected in parallel, we recommend to use a diode in terminal #6 to avoid the current to flow in opposite direction, which might damage the control board. External V + - # 6 # # 6 # # 6 # # 6 # 7 n k 6 _ Tel: Fax:

41 cabling and connections vacon Control connections The basic control connections for boards A1 and A2/A3 are shown in Chapter The signal descriptions for the standard application are presented in Chapter 2 of the All in One Application Manual. You can find the signal descriptions for other applications in the Vacon NX Application Manual. Board OPT-A1 in slot A OPT-A2 OPT-A3 Boards OPT-A2 and OPT-A3 in slot B Figure 6-9. The I/O terminals of the two basic boards Basic I/O board NXOPTA Vref AIA1+ GND AIA2+ AIA2-24Vout GND DIA1 DIA2 DIA3 CMA 24Vout GND DIB4 DIB5 DIB6 CMB Iout+ Iout- DO1 Reference (voltage) Reference (current) 0(4)/20mA RL<500 + U<+48V I<50mA 24 V GND 24 V GND Dotted line indicates the connection with inverted signal levels Figure General wiring diagram of the basic I/O board (NXOPTA1) RO1/1 1/2 RO1/3 RO2/1 2/2 RO2/3 ac/dc Switching: <8A/24Vdc, <0.4A/125Vdc, <2kVA/250Vac Continuously: < 2Arms Switching: <8A/24Vdc, <0.4A/125Vdc, <2kVA/250Vac Continuously: <2Arms RO1/1 1/2 RO1/3 2/1 RO2/2 TI1+ TI1- +t ac/dc Basic relay board OPT-A2 Basic relay board OPT-A3 NX6_6.fh8 24-hour support: +358-(0) vacon@vacon.com 6

42 40 vacon cabling and connections Figure General wiring diagram of the basic relay boards (NXOPTA2/NXOPTA3) Control cables The control cables shall be at least 0.5 mm 2 screened multicore cables, see Table 6-8. The maximum terminal wire size is 2.5 mm 2 for the relay terminals and 1.5 mm 2 for other terminals. You can find the tightening torques of the option board terminals below. Terminal screw Tightening torque Nm lb-in. Relay and thermistor terminals (screw M3) Other terminals (screw M2.6) Table 6-8. Tightening torques of terminals Galvanic isolation barriers The control connections are isolated from the mains potential and the GND terminals are permanently connected to ground. See below. The digital inputs are galvanically isolated from the I/O ground. The relay outputs are additionally double-isolated from each other at 300VAC (EN-50178). 10Vref GND +24V GND AI1 AI2+ AI2 - DIN1... DIN3 CMA DIN4... DIN6 CMB AO1+ AO2 - DO1 Control I/O ground Digital input group A Digital input group B Analogue output Digital output Control panel Control board Gate drivers DC+ DC- Power board RO1/1 RO1/2 RO1/3 RO2/1 RO2/2 RO2/3 U V W TI1+ TI1- nk6_15 Figure Galvanic isolation barriers 6 Tel: Fax:

43 cabling and connections vacon Control terminal signals Terminal Signal Technical information Vref Reference voltage Maximum current 10 ma 2 AI1+ Analogue input, voltage or current Selection V or ma with jumper block X1 (see page 44): Default: 0 +10V (Ri = 200 k ) (-10V..+10V Joy-stick control, selected with a jumper) 0 20mA (Ri = 250 ) 3 GND/AI1 Analogue input common Differential input if not connected to ground; Allows 20V differential mode voltage to GND 4 AI2+ Analogue input, voltage or current Selection V or ma with jumper block X1 (see page 44): Default: 0 20mA (Ri = 250 ) 0 +10V (Ri = 200 k ) (-10V..+10V Joy-stick control, selected with a jumper) 5 GND/AI2 Analogue input common Differential input if not connected to ground; Allows 20V differential mode voltage to GND 6 24 Vout (bidirectional) 24V auxiliary voltage 15%; maximum current 250 ma all boards total; 150 ma from single board. Can also be used as external power backup for the control unit (and fieldbus). 7 GND I/O ground Ground for reference and controls 8 DIN1 Digital input 1 9 DIN2 Digital input 2 10 DIN3 Digital input 3 11 CMA Digital input common A for DIN1, DIN2 and DIN3. R i = min. 5k 18 30V < "1" Vout 24V auxiliary voltage Same as terminal #6 (bidirectional) 13 GND I/O ground Same as terminal #7 14 DIN4 Digital input 4 15 DIN5 Digital input 5 16 DIN6 Digital input 6 17 CMB Digital input common B for DIN4, DIN5 and DIN6 Must be connected to GND or 24V of I/O terminal or to external 24V or GND Selection with jumper block X3 (see page 44): R i = min. 5k 18 30V < "1" Must be connected to GND or 24V of I/O terminal or to external 24V or GND Selection with jumper block X3 (see page 44): 18 AO1+ Analogue signal (+output) Output signal range: 19 AO1 Analogue output common Current 0(4) 20mA, R L max. 500 or Voltage 0 10V, R L >1k Selection with jumper block X3 (see page 44): 20 DO1 Open collector output Maximum U in = 48VDC Maximum current = 50 ma Table 6-9. Control I/O terminal signals on basic I/O board NXOPTA1 24-hour support: +358-(0) vacon@vacon.com 6

44 42 vacon cabling and connections NXOPTA2 21 RO1/1 Relay output 1 Switching capacity 24VDC/8A 22 RO1/2 250VAC/8A 23 RO1/3 125VDC/0.4A Min.switching load 5V/10mA 24 RO2/1 Relay output 2 Switching capacity 24VDC/8A 25 RO2/2 250VAC/8A 26 RO2/3 125VDC/0.4A Min.switching load 5V/10mA Table Control I/O terminal signals on basic relay board NXOPTA2 NXOPTA3 21 RO1/1 Relay output 1 Switching capacity 24VDC/8A 22 RO1/2 250VAC/8A 23 RO1/3 125VDC/0.4A Min.switching load 5V/10mA RO2/1 RO2/2 Relay output 2 Switching capacity 24VDC/8A 250VAC/8A 125VDC/0.4A Min.switching load 5V/10mA 28 TI1+ 29 TI1 Thermistor input Table Control I/O terminal signals on basic relay board NXOPTA Digital input signal inversions The active signal level depends on which potential the common inputs CMA and CMB (terminals 11 and 17) are connected to. The alternatives are either +24V or ground (0 V). See Figure We recommend the use of positive logic in all control connections of the inverter. If negative logic is used, additional appropriate measures are needed to meet the safety regulation requirements. The 24 volt control voltage and the ground for the digital inputs and the common inputs (CMA, CMB) can be either internal or external. Figure Positive/Negative logic +24V Ground Ground nk6_16 DIN1 DIN2 DIN3 CMA Positive logic (+24V is the active signal) = the input is active when the switch is closed DIN1 DIN2 DIN3 +24V CMA Negative logic (0V is the active signal) = the input is active when the switch is closed. Requires setting of jumper X3 to position CMA/CMB isolated from ground 6 Tel: Fax:

45 cabling and connections vacon Jumper selections on the NXOPTA1 basic board The user can customise the functions of the inverter to better suit his needs by selecting certain positions for the jumpers on the NXOPTA1 board. The positions of the jumpers determine the signal type of analogue and digital inputs. On the A1 basic board, there are four jumper blocks (X1, X2, X3 and X6) each containing eight pins and two jumpers. The selection possibilities of the jumpers are shown on page 44 (Figure 6-15). Figure Jumper blocks on NXOPTA1 24-hour support: +358-(0)

46 44 vacon cabling and connections Jumper block X1: AI1 mode A B C D Jumper block X2: AI2 mode A B C D AI1 mode: mA; Current input AI2 mode : mA; Current input A B C D A B C D AI1 mode: Voltage input; V AI2 mode: Voltage input; V A B C D A B C D AI1 mode: Voltage input; V (differential) AI2 mode: Voltage input; V (differential) A B C D A B C D AI1 mode: Voltage input; V Jumper block X6: AO1 mode A B C D AO1 mode: mA; Current output A B C D AI2 mode: Voltage input; V Jumper block X3: CMA and CMB grounding CMB connected to GND CMA connected to GND CMB isolated from GND CMA isolated from GND CMB and CMA internally connected together, isolated from GND AO1 mode: Voltage output; V = Factory default Figure Jumper selection for NXOPTA1! VAROITUS! HUOM! Ensure that the jumper positions are correct. Running the motor with signal settings that differ from the jumper positions will not harm the inverter but may harm the motor. Note: If you change the AI/AO signal content also remember to changer the corresponding board parameter in menu M7. 6 Tel: Fax:

47 control keypad vacon CONTROL KEYPAD The control keypad is the link between the Vacon inverter and the user. The Vacon NX control keypad features an alphanumeric display with seven indicators for the Run status (RUN,,, STOP, ALARM, FAULT) and three indicators for the control place (I/O term/ Keypad/BusComm). There are also three Status Indicator LEDs (green green red), see section The control information, i.e. the menu number, description of the menu or the displayed value and the numeric information are presented on three text lines. The inverter is operable through the nine push-buttons of the control keypad. Furthermore, the buttons can be used in setting parameters and monitoring values. The keypad is detachable and isolated from the input line potential. 7.1 Indicators on the keypad display RUN STOP ALARM FAULT I/O term Keypad Bus/Comm a b c ready run fault Figure 7-1. Vacon control keypad and drive status indications Drive status indications I II II I 7045.jpg The drive status symbols tell the user the status of the motor and the inverter. In addition, they tell about possible irregularities detected by the motor control software in motor or inverter functions RUN STOP = Motor is running; Blinks when the stop command has been given but the frequency is still ramping down. = Indicates the direction of motor rotation. = Indicates that the drive is not running. 24-hour support: +358-(0) vacon@vacon.com 7

48 46 vacon control keypad = Lights up when AC power is on. In case of a trip, the symbol will not light up. ALARM = Indicates that the drive is running outside a certain limit and a warning is given. FAULT = Indicates that unsafe operating conditions were encountered due to which the drive was stopped Control place indicators The symbols I/O term, Keypad and Bus/Comm (see Figure 7-1) indicate the choice of control place made in the Keypad control menu (M3) (see Chapter 7.3.3). a b c I/O term Keypad Bus/Comm = I/O terminals are selected as the control place i.e. START/STOP commands or reference values etc. are given through the I/O terminals. = Control keypad is selected as the control place i.e. the motor can be started or stopped, or its reference values etc. altered from the keypad. = The inverter is controlled through a fieldbus Status LEDs (green green red) The status LEDs light up in connection with the, RUN and FAULT drive status indicators. I II III = lights up with the AC power connected to the drive. Simultaneously, the drive status indicator is lit up. = Lights up when the drive is running. Blinks when the STOP button has been pushed and the drive is ramping down. = Lights up when unsafe operating conditions were encountered due to which the drive was stopped (Fault Trip). Simultaneously, the drive status indicator FAULT blinks on the display and the fault description can be seen, see Chapter , Active faults. 7 Tel: Fax:

49 control keypad vacon Text lines The three text lines (,, ) provide the users with information on their present location in the keypad menu structure as well as with information related to the operation of the drive. = Location indicator; displays the symbol and number of the menu, parameter, etc. Example: M2 = Menu 2 (Parameters); P2.1.3 = Acceleration time = Description line; Displays the description of the menu, value or fault. = Value line; Displays the numerical and textual values of references, parameters, etc. and the number of submenus available in each menu. 24-hour support: +358-(0) vacon@vacon.com 7

50 48 vacon control keypad 7.2 Keypad push-buttons The Vacon alphanumeric control keypad has 9 push-buttons that are used for controlling the inverter (and motor), setting parameters, and monitoring values. Figure 7-1 Keypad push-buttons Button descriptions reset = This button is used to reset active faults (see Chapter ). select = This button is used to switch between the two latest displays. This may be useful when you want to see how the changed new value influences some other value. enter = The enter button is used for: 1) confirmation of selections 2) fault history reset (2 3 seconds) = Browser button up Browse the main menu and the pages of different submenus. Edit values. = Browser button down Browse the main menu and the pages of different submenus. Edit values. = Menu button left Move backward in menu. Move cursor left (in parameter menu). Exit edit mode. Press for 2 to 3 seconds to return to main menu. 7 Tel: Fax:

51 control keypad vacon 49 = Menu button right Move forward in menu. Move cursor right (in parameter menu). Enter edit mode. = Start button Pressing this button starts the motor if the keypad is the active control place. See Chapter = Stop button Pressing this button stops the motor (unless disabled by parameter R3.4/R3.6). See Chapter Navigation on the control keypad The data on the control keypad is arranged in menus and submenus. The menus are used for the display and editing of measurement and control signals, parameter settings (see Chapter 7.3.2) and reference value and fault displays (see Chapter ). Through the menus, you can also adjust the contrast of the display (see Chapter ). Location Description Number of items available RUN Local Monitor V1èV14 The first menu level consists of menus M1 to M7 and is called the Main menu. The user can navigate in the main menu with the Browser buttons up and down. The desired submenu can be entered from the main menu with the Menu buttons. When there still are pages to enter under the currently displayed menu or page, you can see an arrow ( ) in the lower right corner of the display and can reach the next menu level by pressing Menu button right. The control keypad navigation chart is shown on the next page. Please note that menu M1 is located in the lower left corner. From there you will be able to navigate your way up to the desired menu using the menu and browser buttons. You will find more detailed descriptions of the menus later in this chapter. 24-hour support: +358-(0) vacon@vacon.com 7

52 50 vacon control keypad Expander boards G1èG5 R EADY A:NXOPTA1 G1èG1 R EADY Parameters P1èP3 STOP R EADY System Menu S1èS9 STOP R EADY Language English enter Browse Change value Fault history 11 Output phase Operation days H1èH3 T1èT7 17 STOP FAULT STOP FAULT STOP FAULT Active faults F0 or: 11 Output phase Operation days F T1 èt7 17 STOP R EADY STOP R EADY Keypad control P1èP3 Control Place I/O Terminal enter Browse Change value R EADY R EADY Loc al Parameters Basic parameters Min Frequency G1èG9 P1èP Hz enter Browse Change value RU N R EADY RUN Monitor Output frequency No editing! V1èV Hz Figure 7-2 Keypad navigation chart 7 Tel: Fax:

53 control keypad vacon Monitoring menu (M1) You can enter the Monitoring menu from the Main menu by pressing Menu button right when the location indication M1 is visible on the first line of the display. Figure 3-1 shows how to browse through the monitored values. The monitored signals carry the indication V#.# and they are listed in Table 7-1. The values are updated once every 0.3 seconds. This menu is meant only for signal checking. The values cannot be altered here. For changing values of parameters, see Chapter RUN R EADY Local FreqReference Hz RUN Local Monitor V1èV14 RUN Local Output frequency Hz Figure 7-3 Monitoring menu Code Signal name Unit Description Output frequency Hz Frequency to the motor Frequency reference Hz Motor speed rpm Calculated motor speed Motor current A Measured motor current Motor torque % Calculated actual torque/nominal torque of the unit Motor power % Calculated actual power/nominal power of the unit Motor voltage V Calculated motor voltage DC-link voltage V Measured DC-link voltage Unit temperature ºC Heat sink temperature Motor temperature % Calculated motor temperature Voltage input V AI1 Current input ma AI2 DIN1, DIN2, DIN3 Digital input statuses DIN4, DIN5, DIN6 Digital input statuses DO1, RO1, RO2 Digital and relay output statuses Analogue output ma AO1 M1.17 current Displays three selectable monitoring values. See Multimonitoring items chapter Table 7-1. Monitored signals Note! All in One applications may embody more monitoring values. 24-hour support: +358-(0) vacon@vacon.com 7

54 52 vacon control keypad Parameter menu (M2) Parameters are the way of conveying the commands of the user to the inverter. Parameter values can be edited by entering the Parameter Menu from the Main Menu when the location indication M2 is visible on the first line of the display. The value editing procedure is presented in Figure 7-1. Pressing Menu button right once takes you to the Parameter Group Menu (G#). Locate the desired parameter group by using the Browser buttons and press Menu button right again to see the group and its parameters. Use the Browser buttons to find the parameter (P#) you want to edit. Pressing Menu button right takes you to the edit mode. As a sign of this, the parameter value starts to blink. You can now change the value in two different ways: Set the desired value with the Browser buttons and confirm the change with the enter button. Consequently, the blinking stops and the new value is visible in the value field. Press Menu button right once more. Now you will be able to edit the value digit by digit. This may come in handy, when a relatively greater or smaller value than that on the display is desired. Confirm the change with the enter button. The value will not change unless the Enter button is pressed. Pressing Menu button left takes you back to the previous menu. Several parameters are locked, i.e. cannot be edited, when the drive is in RUN status. If you try to change the value of such a parameter the text *Locked* will appear on the display. The inverter must be stopped to edit these parameters. The parameter values can also be locked using the function in menu M6 (see Chapter6.5.2)). You can return to the Main menu any time by pressing Menu button left for 1 to 2 seconds. The basic application package "All in One+" includes seven applications with different sets of parameters. You will find the parameter lists in the Application Section of this manual. Once in the last parameter of a parameter group, you can move directly to the first parameter of that group by pressing Browser button up. See the diagram for parameter value change procedure on page 53. Note: You can connect power to the control board by connecting the external power source to the bidirectional terminal #6 on the NXOPTA1 board (see page 41). The external power source can also be connected to the corresponding +24V terminal on any option board. This voltage is sufficient for parameter setting and for keeping the fieldbus active. 7 Tel: Fax:

55 control keypad vacon 53 Keypad Input signals G1èG8 Keypad Keypad Keypad Parameters Basic parameters Min Frequency G1èG8 P1èP Hz Keypad Min Frequency Hz enter Keypad Min Frequency Hz Figure 7-1. Parameter value change procedure 24-hour support: +358-(0)

56 54 vacon control keypad Keypad control menu (M3) In the Keypad Control Menu, you can choose the control place, edit the frequency reference and change the direction of the motor. You can enter the submenu level by pressing Menu button right Selection of control place There are three different places (sources) where the inverter can be controlled from. For each control place, a different symbol will appear on the alphanumeric display: Control place I/O terminals Keypad (panel) Fieldbus Symbol I/O term Keypad Bus/Comm You can change the control place by entering the edit mode with Menu button right. The options can then be browsed with the Browser buttons. Select the desired control place with the enter button. See the diagram on the next page. See also Chapter above. STOP STOP STOP Keypad control P1èP4 Control Place I/O Remote Control Place I/O Remote STOP Control Place Keypad enter STOP Keypad Control Place Keypad Figure 7-2. Selection of control place Keypad reference The keypad reference submenu (P3.2) displays and allows the operator to edit the frequency reference. The changes will take place immediately. This reference value will not, however, influence the rotation speed of the motor unless the keypad has been selected as the active control place. NOTE: The maximum difference in RUN mode between the output frequency and the keypad reference is 6 Hz. The program automatically monitors the keypad reference value. See also Chapter Figure 7-1 shows how to edit the reference value (pressing the enter button is not necessary). 7 Tel: Fax:

57 control keypad vacon Keypad direction The keypad direction submenu (P3.3) displays and allows the operator to change the rotating direction of the motor. This setting will not, however, influence the rotation direction of the motor unless the keypad has been selected as the active control place. See also Chapter Note: For additional information on controlling the motor with the keypad, see Chapters 7.2.1, and Stop button activated By default, pushing the STOP button will always stop the motor regardless of the selected control place. You can disable this function by giving parameter 3.4 the value 0. If the value of this parameter is 0, the STOP button will stop the motor only when the keypad has been selected as the active control place. NOTE! There are some special functions that can be performed in menu M3: Select the keypad as the active control place by pressing START for 3 seconds when the motor is running. The keypad will become the active control place and the current frequency reference and direction will be copied to the keypad. Select the keypad as the active control place by pressing STOP for 3 seconds when the motor is stopped. The keypad will become the active control place and the current frequency reference and direction will be copied to the keypad. Copy the frequency reference set elsewhere (I/O, fieldbus) to the panel by pressing enter for 3 seconds. Note that if you are in any other than menu M3 these functions will not work. If you are in some other than menu M3 and try to start the motor by pressing the START button when the keypad is not selected as the active control place, you will get an error message: Keypad Control NOT ACTIVE. 24-hour support: +358-(0) vacon@vacon.com 7

58 56 vacon control keypad Active faults menu (M4) You can enter the Active faults menu from the Main menu by pressing Menu button right when the location indication M4 is visible on the first line of the keypad display. When a fault brings the inverter to a stop, the location indication F1, the fault code, a short description of the fault, and the fault type symbol (see Chapter ) will appear on the display. In addition, the indication FAULT or ALARM (see Figure 7-1 or Chapter 7.1.1) is displayed and, in case of a FAULT, the red LED on the keypad starts to blink. If several faults occur simultaneously, the list of active faults can be browsed with the Browser buttons. The memory of active faults can store a maximum of 10 faults in the order of appearance. The display can be cleared with the reset button and the read-out will return to the same state it was in before the fault trip. The fault remains active until it is cleared with the reset button or with a reset signal from the I/O terminal. Note! Remove external Start signal before resetting the fault to prevent unintentional restart of the drive. Normal state, no faults Active faults F Fault types The NX inverter has four types of faults. These types differ from each other on the basis of the subsequent behaviour of the drive. See Table 7-1. Operation hours 34:21:05 Fault type symbol F T1 èt13 Figure 7-3. Fault display STOP FAULT STOP FAULT 11 Output phase Operations days 17 7 Tel: Fax:

59 control keypad vacon 57 Fault type symbol A (Alarm) F (Fault) AR (Fault Autoreset) FT (Fault Trip) Table 7-1. Fault types Meaning This type of fault is a sign of an unusual operating condition. It does not cause the drive to stop, nor does it require any special actions. The 'A fault' remains in the display for about 30 seconds. An 'F fault' makes the drive stop. Actions need to be taken to restart the drive. If an 'AR fault' occurs the drive will stop immediately. The fault is reset automatically and the drive tries to restart the motor. Finally, if the restart is not successful, a fault trip (FT, see below) occurs. If the drive is unable to restart the motor after an AR fault an FT fault occurs. The 'FT fault' has basically the same effect as the F fault: the drive is stopped. 24-hour support: +358-(0) vacon@vacon.com 7

60 58 vacon control keypad Fault codes The fault codes, their causes and correcting actions are presented in the table below. The shadowed faults are A faults only. The items in white on black background are faults for which you can program different responses in the application. See parameter group Protections. Note! When contacting the distributor or factory because of a fault condition, always write down all texts and codes visible on the keypad display. Fault Fault Possible cause Correcting measures code 1 Overcurrent Inverter has detected too high a current (>4*I n ) in the motor cable: sudden heavy load increase Check loading. Check motor. Check cables. short circuit in motor cables unsuitable motor 2 Overvoltage The DC-link voltage has exceeded the limits defined in Table 4-3 Set the deceleration time longer. Add a brake chopper or a brake resistor. too short a deceleration time high overvoltage spikes in supply 3 Earth fault Current measurement has detected that the sum of motor phase current is not zero. insulation failure in cables or motor Check motor cable and motor. 5 Charging switch The charging switch is open, when the START command has been given. faulty operation component failure 6 Emergency stop Stop signal has been given from the option board. 7 Saturation trip Various causes: component failure brake resistor short-circuit or overload 8 System fault component failure faulty operation Note the exceptional Fault data record. See Undervoltage DC-link voltage is under the voltage limits defined in Table 4-3. most probable cause: too low a supply voltage inverter internal fault Reset the fault and restart. Should the fault re-occur, contact the distributor near to you. Cannot be reset from the keypad. Switch off power. DO NOT RE-CONNECT POWER! Contact factory. If this fault appears simultaneously with Fault 1, check motor cables and motor Reset the fault and restart. Should the fault re-occur, contact the distributor near to you. In case of temporary supply voltage break, reset the fault and restart the inverter. Check the supply voltage. If it is adequate, an internal failure has occurred. Contact the nearest Vacon distributor. 11 Output phase supervision 12 Brake chopper supervision Current measurement has detected that there is no current in one motor phase. No brake resistor installed brake resistor is broken brake chopper failure Check motor cable and motor. Check brake resistor. If the resistor is ok, the chopper is faulty. Contact the distributor near to you. 7 Tel: Fax:

61 control keypad vacon 59 Fault Fault Possible cause Correcting measures code 13 Inverter Heatsink temperature is under 10 C undertemperatur e 14 Inverter overtemperature Heatsink temperature is over 90 C or 77ºC (NX_6, FR6). Overtemperature warning is issued when the heatsink temperature exceeds 85 C (72ºC). Check the correct amount and flow of cooling air. Check the heatsink for dust. Check the ambient temperature. Make sure that the switching frequency is not too high in relation to ambient temperature and motor load. 15 Motor stalled Motor stall protection has tripped. Check motor. 16 Motor overtemperature Motor overheating has been detected by inverter motor temperature model. Motor is overloaded. Decrease the motor load. If no motor overload exists, check the temperature model parameters. 17 Motor underload Motor underload protection has tripped. 22 EEPROM checksum fault Parameter save fault faulty operation component failure 24 Counter fault Values displayed on counters are incorrect 25 Microprocessor watchdog fault faulty operation component failure 26 Start-up prevented Start-up of the drive has been prevented. 29 Thermistor fault The thermistor input of option board has detected increase of the motor temperature 31 IGBT temperature (hardware) IGBT Inverter Bridge overtemperature protection has detected too high a short term overload current 32 Fan cooling Cooling fan of the inverter does not start, when ON command is given. 34 CAN bus Sent message not acknowledged. communication 36 Control unit NXS Control Unit can not control NXP Power Unit and vice versa 37 Device changed Option board or control unit changed. (same type) Same type of board or same power rating of drive. 38 Device added (same type) Option board or drive added. Drive of same power rating or same type of board added. Reset the fault and restart. Should the fault re-occur, contact the distributor near to you. Cancel prevention of start-up. Check motor cooling and loading Check thermistor connection (If thermistor input of the option board is not in use it has to be short circuited) Check loading. Check motor size. Contact the nearest Vacon distributor. Ensure that there is another device on the bus with the same configuration. Change control unit Reset Note: No fault time data record! Reset Note: No fault time data record! 39 Device removed Option board removed. Reset Drive removed. Note: No fault time data record! 40 Device unknown Unknown option board or drive. Contact the nearest Vacon distributor. 24-hour support: +358-(0) vacon@vacon.com 7

62 60 vacon control keypad Fault Fault Possible cause Correcting measures code 41 IGBT temperature IGBT Inverter Bridge overtemperature protection has detected too high a short Check loading. Check motor size. term overload current 42 Brake resistor overtemperature Brake resistor overtemperature protection has detected too heavy braking Set the deceleration time longer. Use external brake resistor. 43 Encoder fault Note the exceptional Fault data record. See Additional codes: 1 = Encoder 1 channel A is missing 2 = Encoder 1 channel B is missing 3 = Both encoder 1 channels are missing 4 = Encoder reversed 44 Device changed (different type) 45 Device added (different type) 50 Analogue input (sel. signal range 4 to 20 ma) Option board or control unit changed. Option board of different type or different power rating of drive. Option board or drive added. Option board of different type or drive of different power rating added. Current at the analogue input is < 4mA. control cable is broken or loose signal source has failed 51 External fault Digital input fault. 52 Keypad communication fault There is no connection between the control keypad and the inverter. 53 Fieldbus fault The data connection between the fieldbus Master and the fieldbus board is broken Check encoder channel connections. Check the encoder board. Reset Note: No fault time data record! Note: Application parameter values restored to default. Reset Note: No fault time data record! Note: Application parameter values restored to default. Check the current loop circuitry. Check keypad connection and possible keypad cable. Check installation. If installation is correct contact the nearest Vacon distributor. 54 Slot fault Defective option board or slot Check board and slot. Contact the nearest Vacon distributor. 56 PT100 board temp. fault Table 7-2. Fault codes Temperature limit values set for the PT100 board parameters have been exceeded Find the cause of temperature rise 7 Tel: Fax:

63 control keypad vacon Fault time data record When a fault occurs, the information described in Chapter is displayed. By pressing Menu button right, you will enter the Fault time data record menu indicated by T.1 T.#. In this menu, some selected important data valid at the time of the fault are recorded. This feature will help the user or the service person in determining the cause of the fault. The data available are: T.1 Counted operation days (Fault 43: Additional code) T.2 Counted operation hours (Fault 43: Counted operation days) T.3 Output frequency (Fault 43: Counted operation hours) (d) (hh:mm: ss) (d) Hz (hh:mm: ss) T.4 Motor current A T.5 Motor voltage V T.6 Motor power % T.7 Motor torque % T.8 DC voltage V T.9 Unit temperature C T.10 Run status T.11 Direction T.12 Warnings T.13 0-speed* Table 7-3. Fault time recorded data * Tells the user if the drive was at zero speed (< 0.01 Hz) when the fault occurred Real time record If real time is set to run on the inverter, the data items T1 and T2 will appear as follows: T.1 Counted operation days yyyy-mm-dd T.2 Counted operation hours hh:mm:ss,sss 24-hour support: +358-(0) vacon@vacon.com 7

64 62 vacon control keypad Fault history menu (M5) You can enter the Fault history menu from the Main menu by pressing Menu button right when the location indication M5 is visible on the first line of the keypad display. All faults are stored in the Fault history menu where you can browse them with the Browser buttons. Additionally, the Fault time data record pages (see Chapter ) are accessible for each fault. You can return to the previous menu any time by pressing Menu button left. The memory of the inverter can store a maximum of 30 faults in order of appearance. The number of faults currently in the fault history is shown on the value line of the main page (H1 H#). The order of the faults is indicated by the location indication in the upper left corner of the display. The latest fault is indicated by F5.1, the one before that by F5.2 and so on. If there are 30 uncleared faults in the memory, the next fault will erase the oldest fault from the memory. Pressing the enter button for about 2 to 3 seconds resets the whole fault history. The symbol H# will change to 0. 5 ChargeSwitch I/Oter m Operation hours 13:25:43 Fault history H1èH3 11 Output phase T1èT7 Operation days 17 PUSH enter to reset Figure 7-4. Fault history menu 7 Tel: Fax:

65 control keypad vacon System menu (M6) You can enter the System menu from the Main menu by pressing Menu button right when the location indication M6 is visible on the first line of the keypad display. The controls associated with the general use of the inverter, such as application selection, customised parameter sets or information about the hardware and software are located under the System menu. The number of submenus and subpages is shown with the symbol S (or P) on the value line. Page 64 has a table of the functions available in the System menu. 24-hour support: +358-(0) vacon@vacon.com 7

66 64 vacon control keypad System menu functions Code Function Min Max Unit Default Cust Selections English Deutsch Selection of S6.1 English Suomi language Svenska Italiano S6.2 Application selection Basic Application Basic Application Standard Application Local/Remote control Appl. Multi-Step Application PID Control Application Multi-Purpose Control Appl. Pump and Fan Control Appl. S6.3 Copy parameters S6.3.1 Parameter sets Load factory defaults Store set 1 Load set 1 Store set 2 Load set 2 S6.3.2 Load to keypad All parameters S6.3.3 Load from keypad All parameters All but motor parameters Application parameters P6.3.4 Parameter backup Yes No Yes S6.4 Parameter comparison S6.5 Safety S6.5.1 Password Not used 0=Not used P6.5.2 Parameter locking Change Change Enabled Enabled Change Disabled S6.5.3 Start-up wizard No Yes S6.5.4 Multimonitoring Change items Enabled S6.6 Keypad settings P6.6.1 Default page P6.6.2 Default page/om P6.6.3 Timeout time s 30 P6.6.4 Contrast P6.6.5 Backlight time Always min 10 S6.7 Hardware settings P6.7.1 Internal brake resistor Connected P6.7.2 Fan control function Continuous P6.7.3 HMI acknowledg ms 200 P6.7.4 HMI: no. of retries S6.8 System information S6.8.1 Total counters C MWh counter kwh C Operation day counter C Operation hour counter Change Enabled Change Disabled Not connected Connected Continuous Temperature 7 Tel: Fax:

67 control keypad vacon 65 Code Function Min Max Unit Default Cust Selections S6.8.2 Trip counters T MWh counter kwh T Clear MWh counter T Operation day counter T Operation hour counter T Clear operation hour counter S6.8.3 Software information S Software package S System software version S Firmware interface S System load S6.8.4 Applications S6.8.4.# Name of application D6.8.4.#.1 Application ID D6.8.4.#.2 Applications: version D6.8.4.#.3 Applications: firmware interface S6.8.5 Hardware I Unit power I Unit voltage I Info: Brake chopper I Info: Brake resistor S6.8.6 Expander boards Table 7-4. System menu functions 24-hour support: +358-(0)

68 66 vacon control keypad Selection of language The Vacon control keypad offers you the possibility to control the inverter through the keypad in the language of your choice. Locate the language selection page under the System menu. Its location indication is S6.1. Press Menu button right once to enter the edit mode. As the name of the language starts to blink you can select another language for the keypad texts. Confirm with the enter button. The blinking stops and all text information on the keypad is presented in the selected language. You can return to the previous menu any time by pressing Menu button left. System Menu S1èS11 Language English Language English enter Langue Francais Figure 7-5. Selection of language Application selection The user can select the desired application on the Application selection page (S6.2). To enter the page, press Menu button right on the first page of the System menu. To change the application, press Menu button right once more. The name of the application starts to blink. Now you can browse the applications with the Browser buttons and select the desired application with the enter button. After application change, you will be asked if you want the parameters of the new application to be uploaded to the keypad. If you want to do this, press the enter button. Pressing any other button leaves the parameters of the previously used application saved in the keypad. For more information, see Chapter. For more information about the Application Package, see Vacon NX Application Manual. 7 Tel: Fax:

69 control keypad vacon 67 STOP System Menu S1èS11 STOP Application Standard STOP Application Standard enter STOP Application Multi-step Figure 7-6. Change of application Copy parameters The parameter copy function is used when the operator wants to copy one or all parameter groups from one drive to another. All the parameter groups are first uploaded to the keypad, then the keypad is connected to another drive and then the parameter groups are downloaded to it (or possibly back to the same drive). For more information, see page 68. Before any parameters can be successfully copied from one drive to another, the drive has to be stopped when the parameters are downloaded to it: The parameter copy menu (S6.3) contains four functions: Parameter sets (S6.3.1) The user can reload the factory default parameter values and store and load two customised parameter sets (all parameters included in the application). On the Parameter sets page (S6.3.1), press Menu button right to enter the edit mode. The text LoadFactDef begins to blink and you can confirm the loading of factory defaults by pressing the enter button. The drive resets automatically. Alternatively, you can choose any other storing or loading functions with the Browser buttons. Confirm with the enter button. Wait until 'OK' appears on the display. 24-hour support: +358-(0)

70 68 vacon control keypad enter CONFIRM Parameter sets Select Parameter sets LoadFactDef CANCEL Parameter sets Wait... Parameter sets OK Figure 7-7. Storing and loading of parameter sets Upload parameters to keypad (To keypad, S6.3.2) This function uploads all existing parameter groups to the keypad provided that the drive is stopped. Enter the To keypad page (S6.3.2) from the Parameter copy menu. Pressing Menu button right takes you to the edit mode. Use the Browser buttons to select the option All parameters and press the enter button. Wait until 'OK' appears on the display. P1èP4 Copy Parameters Up to keypad Up to keypad Select All param. enter CONFIRM CHANGE VALUE CANCEL Up to keypad Wait... Up to keypad OK Figure 7-8. Parameter copy to keypad Download parameters to drive (From keypad, S6.3.3) This function downloads one or all parameter groups uploaded to the keypad to a drive provided that the drive is in STOP status. Enter the To keypad page (S6.3.2) from the Parameter copy menu. Pressing the Menu button right takes you to the edit mode. Use the Browser buttons to select either All parameters, All but motor parameters or Application parameters and press the Enter button. Wait until 'OK' appears on the display. The procedure to download the parameters from keypad to drive is similar to that of from drive to keypad. See Figure Tel: Fax:

71 control keypad vacon 69 Automatic parameter backup (P6.3.4) On this page you can activate or inactivate the parameter backup function. Enter the edit mode by pressing Menu button right. Select Yes or No with the Browser buttons. When the Parameter backup function is activated Vacon NX control keypad makes a copy of the parameters of the presently used application. When applications are changed, you will be asked if you wish the parameters of the new application to be uploaded to the keypad. If you want to do this, press the enter button. If you wish to keep the copy of the parameters of the previously used application saved in the keypad, press any other button. Now you will be able to download these parameters to the drive following the instructions given in Chapter If you want the parameters of the new application to be automatically uploaded to the keypad you have to do this for the parameters of the new application once on page as instructed. Otherwise the panel will always ask for the permission to upload the parameters. Note: Parameters saved in the parameter settings on page S6.3.1 will be deleted when applications are changed. If you want to transfer the parameters from one application to another, you have to upload them first to the keypad Parameter comparison In the Parameter comparison submenu (S6.4), you can compare the actual parameter values to the values of your customised parameter sets and those loaded to the control keypad. You can compare the parameter by pressing Menu button right in the Compare parameters submenu. The actual parameter values are first compared to those of the customised parameter Set1. If no differences are detected, '0' is displayed on the lowermost line. If any of the parameter values differ from those of Set1, the number of the deviations is displayed together with symbol P (for example, P1 P5 = five deviating values). By pressing Menu button right once more, you can enter pages where you can see both the actual value and the value it was compared to. In this display, the value on the description line (in the middle) is the default value and the one on the value line (lowermost) is the edited value. Furthermore, you can also edit the actual value with the Browser buttons in the edit mode which you can enter by pressing Menu button right once. 24-hour support: +358-(0) vacon@vacon.com 7

72 70 vacon control keypad ParamComparison C1èC3 Set1 0 OR Set1 P1èP6 P2.1.2= Hz P2.1.2= Hz enter EDIT VALUE CONFIRM CHANGE Figure 7-9. Parameter comparison Safety NOTE: The Security submenu is protected with a password. Store the password in a safe place! Password (S6.5.1) The application selection can be protected against unauthorised changes with the Password function (S6.5.1). By default, the password function is not in use. If you want to activate the function, enter the edit mode by pressing Menu button right. A blinking zero appears in the display and you can set a password with the Browser buttons. The password can be any number between 1 and Note that you can also set the password by digits. In the edit mode, push Menu button right again and another zero appears on the display. Set ones first. To set the tens, press Menu button right, and so on. Confirm the password with the enter button. After this, you have to wait until the Timeout time (P6.6.3) (see page 73) has expired before the password function is activated. If you try to change applications or the password itself, you will be prompted for the current password. Enter the password with the Browser buttons. You can deactivate the password function by entering the value 0. Password Not in use Password 0 OR: enter Password 00 enter Figure Password setting Note! Store the password in a safe place! No changes can be made unless a valid password is entered. 7 Tel: Fax:

73 control keypad vacon 71 Parameter lock (P6.5.2) This function allows the user to prohibit changes to the parameters. If the parameter lock is activated, the text *locked* will appear on the display if you try to edit a parameter value. NOTE: This function does not prevent unauthorised editing of parameter values. Enter the edit mode by pressing Menu button right. Use the Browser buttons to change the parameter lock status. Confirm the change with the enter button or go back to the previous level by pressing Menu button left. System Menu S1èS9 Security P1èP4 Parameter Lock ChangeEnable Parameter Lock ChangeEnable enter Parameter Lock ChangeDisabl Figure Parameter locking Start-up wizard (P6.5.3) The Start-up wizard facilitates the commissioning of the inverter. If active, the Start-up wizard prompts the operator for the language and application of his/her choice and then displays the first menu or page. Activating the Start-up wizard: In the System Menu, find page P Press Menu button right once to enter the edit mode. Use the Browser buttons to select Yes and confirm the selection with the enter button. If you want to deactivate the function, follow the same procedure and give the parameter value No. Startup wizard No Startup wizard No Startup wizard Yes enter CONFIRM CANCEL Figure Activation of Start-up wizard 24-hour support: +358-(0) vacon@vacon.com 7

74 72 vacon control keypad Multimonitoring items (P6.5.4) Vacon alphanumeric keypad features a display where you can monitor up to three actual values at the same time (see Chapter and Chapter Monitoring values in the manual of the application you are using). On page P6.5.4 of the System Menu, you can define whether the operator can replace the values monitored with other values. See below. Multimon. items ChangeEnable Multimon. items ChangeEnable enter Multimon. items ChangeDisable Figure Disabling the change of multimonitoring items Keypad settings In the Keypad settings submenu under the System menu, you can further customise your inverter operator interface. Locate the Keypad setting submenu (S6.6). Under the submenu, there are four pages (P#) associated with the keypad operation: Keypad settings P1èP5 Default page 0. Default page (P6.6.1) Figure Keypad settings submenu Here you can set the location (page) to which the display automatically moves when the Timeout time (see below) has expired or the power is switched on to the keypad. If the Default page is 0, the function is not activated i.e. the latest displayed page remains on the keypad display. Pressing Menu button right takes you to the edit mode. Change the number of the Main menu with the Browser buttons. To edit the number of the submenu/page, press Menu button right. If the page you want to move to by default is at the third level, repeat the procedure. Confirm the new default page with the enter button. You can return to the previous menu at any time by pressing Menu button left. Default page 0. Default page Default page enter CONFIRM CHANGE REPEAT TO SET DEFAULT SUBMENU/PAGE CANCEL Figure Default page function 7 Tel: Fax:

75 control keypad vacon 73 Default page in the operating menu (P6.6.2) Here you can set the location (page) in the Operating menu (in special applications only) to which the display automatically moves to when the set Timeout time (see below) has expired or the power is switched on to the keypad. See how to set the Default page in the above figure. Timeout time (P6.6.3) The Timeout time setting defines the time after which the keypad display returns to the Default page (P6.6.1). (See previous page.) Enter the edit mode by pressing Menu button right. Set the desired timeout time and confirm it with the enter button. You can return to the previous menu at any time by pressing Menu button left. Timeout time Timeout time Timeout time 90 s 90 s. 60 s. Figure Timeout time setting Note: If the Default page value is 0 the Timeout time setting has no effect. enter CONFIRM CHANGE CANCEL Contrast adjustment (P6.6.4) In case the display is unclear, you can adjust its contrast through the same procedure as for the timeout time setting (see above). Backlight time (P6.6.5) By giving a value for the Backlight time, you can determine how long the backlight stays on before going out. You can select any time between 1 and minutes or 'Forever'. For the value setting procedure, see Timeout time (P6.6.3). 24-hour support: +358-(0) vacon@vacon.com 7

76 74 vacon control keypad Hardware settings NOTE: The Hardware settings submenu is protected with a password. Store the password in a safe place! In the Hardware settings submenu (S6.7) under the System menu, you can further control some functions of the hardware in your inverter. The functions available in this menu are Internal brake resistor connection, Fan control, HMI acknowledge timeout and HMI retry. Internal brake resistor connection (P6.7.1) This function tells the inverter, whether the internal brake resistor is connected or not. If you have ordered the inverter with an internal brake resistor, the default value of this parameter is Connected. However, if it is necessary to increase braking capacity by installing an external brake resistor, or if the internal brake resistor is disconnected for another reason, it is advisable to change the value of this function to Not conn. in order to avoid unnecessary fault trips. Enter the edit mode by pressing Menu button right. You can change the brake resistor information with the Browser buttons. Confirm the change with the enter button or return to the previous level with Menu button left. Note! The brake resistor is available as optional equipment for all classes. It can be installed internally in classes FR4 to FR6. System Menu S1èS8 HW settings P1èP4 InternBrakeRes Connected InternBrakeRes Connected enter InternBrakeRes Not conn. Figure Internal brake resistor connection Fan control (P6.7.2) This function allows you to control the cooling fan of the inverter. You can set the fan to run continuously when the power is switched on or depending on the temperature of the unit. If the latter function has been selected, the fan is switched on automatically when the heatsink temperature reaches 60 C. The fan receives a stop command when the heatsink temperature falls to 55 C. After the command, the fan runs for approximately 1 minute before stopping. The same happens after switching on the power and after changing the value from Continuous to Temperature. Note! The fan runs always when the drive is in RUN state. 7 Tel: Fax:

77 control keypad vacon 75 To change the value: Enter the edit mode by pressing Menu button right. The value starts blinking. Use the Browser buttons to change the fan mode and confirm the change with the enter button. If you do not want to change the value, return to the previous level with Menu button left. See Figure Fan control Continuous Fan control Continuous enter Fan control Temperature Figure Fan control function HMI acknowledge timeout (P6.7.3) This function allows the user to change the timeout of the HMI acknowledgement time. The inverter waits for the HMI acknowledgment in accordance with the value of this parameter. Note! If the inverter has been connected to the PC with a normal cable, the default values of parameters and (200 and 5) must not be changed. If the inverter has been connected to the PC via a modem and there is a delay in transferring messages, the value of parameter must be set according to the delay as follows: Example: Transfer delay between the inverter and the PC = 600 ms The value of par is set to 1200 ms (2 x 600, sending delay + receiving delay) The corresponding setting shall be entered in the Misc part of the file NCDrive.ini: Retries = 5 AckTimeOut = 1200 TimeOut = 6000 It must also be considered that intervals shorter than the AckTimeOut time cannot be used in NC-Drive monitoring. Enter the edit mode by pressing Menu button right. The current value starts to blink. Use the Browser buttons to change the acknowledgement time. Confirm the change with the enter button or return to the previous level with Menu button left. 24-hour support: +358-(0) vacon@vacon.com 7

78 76 vacon control keypad HMI ACK timeout 200ms HMI ACK timeout 200ms enter Figure HMI acknowledge timeout Number of retries to receive HMI acknowledgement (P6.7.4) With this parameter you can set the number of times the drive will try to receive acknowledgement if it does not receive acknowledgement within the acknowledgement time (P6.7.3) or if the received acknowledgement is faulty. You can change value through the same procedure as for P6.7.3 (see above). Note! Changes to P6.7.3 and P6.7.4 become effective after the next start-up System info In the System info submenu (S6.8) you can find inverter-related hardware and software information. You can enter the System info submenu by pressing Menu button right. You can now browse the submenu pages with the Browser buttons. Total counters The Total counters menu (S6.8.1) contains information on the inverter operation times i.e. the total number of MWh, operation days and operation hours. Unlike the counters in the Trip counters menu, these counters cannot be reset. Note! The Power On time counter (days and hours) runs always when the power is on. Page Counter C MWh counter C Operation day counter C Operation hour counter Table 7-5. Counter pages 7 Tel: Fax:

79 control keypad vacon 77 Trip counters Trip counters (menu S6.8.2) are counters the values of which can be reset i.e. restored to zero. You can use the following resettable counters: Note! The trip counters run only when the motor is running. Page Counter T MWh counter T Operation day counter T Operation hour counter Table 7-6. Resettable counters The counters can be reset on pages (Clear MWh counter) and (Clear Operation time counter). Example: When you want to reset the operation counters you should do the following: STOP STOP Trip counters Clr Optime cntr Clr Optime cntr T1èT5 Not reset Not reset STOP STOP STOP Clr Optime cntr Reset enter Clr Optime cntr Reset Clr Optime cntr Not reset Figure Counter reset Software (S6.8.3) The Software information page includes information on the following inverter software related topics: Page Content Software package System software version Firmware interface System load Table 7-7. Software information pages Applications (S6.8.4) At location S6.8.4, you can find the Applications submenu containing information on the application currently in use and all other applications loaded into the inverter. The following information is available: Page Content # Name of application #.1 Application ID #.2 Version #.3 Firmware interface Table 7-8. Applications information pages 24-hour support: +358-(0)

80 78 vacon control keypad In the Applications information page, press Menu button right to enter the Application pages of which there are as many as there are applications loaded into the inverter. Locate the desired application with the Browser buttons and then enter the Information pages with Menu button right. Use the Browser buttons to see the different pages. Standard D1èD3 Version 2.01 Applications A1 èa7 Basic D1 èd3 Application id NXFIFF01 Figure Applications info submenu Hardware (S6.8.5) The Hardware information page provides information on the following hardware-related topics: Page Content Nominal power of the unit Nominal voltage of the unit Brake chopper Brake resistor Table 7-9. Hardware information pages Expander boards (S6.8.6) The Expander boards submenu contains information about the basic and option boards. (See Chapter 6.2) You can check the status of each board slot by entering the Expander boards page with Menu button right. Use the Browser buttons to view the status of each board slot. The description line of the keypad will display the type of the expansion board and the text 'Run' is shown below it. If no board is connected to the slot the text 'no board' will be shown. If a board is connected to a slot but the connection is lost for some reason, the text 'no conn.' is displayed. For more information, see Chapter 6.2, Figure 6-7. For more information on expander board related parameters, see Chapter Tel: Fax:

81 control keypad vacon 79 B:NXOPTA2 Software version E1èE Expander boards E1èE5 A:NXOPTA1 E1èE2 State Run Figure Expander board information menus 24-hour support: +358-(0)

82 80 vacon control keypad Expander board menu (M7) In the Expander board menu the user can 1) see the expander boards connected to the control board and 2) see and edit the parameters associated with the expander boards. Go to the next menu level (G#) with Menu button right. At this level, you can browse through slots A to E (see page 38) with the Browser buttons to see which expander boards are connected to the control board. On the lowermost line of the display, you will also see the number of parameters associated with the board. You can view and edit the parameter values as described in Chapter See Table 7-10 and Figure Expander board parameters Code Parameter Min Max Default Cust Selections P AI1 mode <0 20 ma 2<4 20 ma 3<0 10 V 4<2 10 V 5= V P AI2 mode See P P AO1 mode <0 20 ma 2<4 20 ma 3<0 10 V 4<2 10 V Table Expander board parameters (board NXOPTA1) REA DY D:NXOPTC2 G1èG2 REA DY Monitor V1èV2 Expander boards G1èG5 C:NXOPTC1 G1èG2 Parameters P1èP4 Slave address 126 Slave address 126 enter CHANGE VALUE CONFIRM CHANGE REA DY Baud rate Auto Figure Expander board information menu 7 Tel: Fax:

83 control keypad vacon Further keypad functions The Vacon NX control keypad contains additional application-related functions. See Vacon NX Application Package for more information. 24-hour support: +358-(0)

84 82 vacon commissioning 8. COMMISSIONING 8.1 Safety Before commissioning, note the following directions and warnings: WARNING HOT SURFACE Internal components and circuit boards of the inverter (except for the galvanically isolated I/O terminals) are live when Vacon NX is connected to mains potential. Coming into contact with this voltage is extremely dangerous and may cause death or severe injury. The motor terminals U, V, W and the DC-link/brake resistor terminals+/- are live when Vacon NX inverter is connected to DC supply, even if the motor is not running. The control I/O-terminals are isolated from the mains potential. However, the relay outputs and other I/O-terminals may have a dangerous control voltage present even when Vacon NX is disconnected from DC supply. Do not make any connections when the inverter is connected to the DC supply. After having disconnected the inverter, wait until the fan stops and the indicators on the keypad go out (if no keypad is attached see the indicator through the keypad base). Wait 5 more minutes before doing any work on Vacon NX connections. Do not open the cover before the time has expired. Before connecting the inverter to DC supply make sure that the Vacon NX front cover is closed. When running, the side of inverter FR8 is burning hot. Do not touch it with bare hands! When running, the back of inverter FR6 is burning hot. Therefore it MUST NOT be mounted onto a surface which is not fireproof. 8.2 Commissioning the inverter 1 Read carefully the safety instructions in Chapter 1 and above and follow them. 2 After the installation, make sure that: both the inverter and the motor are grounded the DC supply and motor cables comply with the requirements given in Chapter the control cables are located as far as possible from the power cables (see Chapter 6.1.2, step 2) and the shields of the shielded cables are connected to protective earth wires may not touch the electrical components of the inverter. the common inputs of digital input groups are connected to +24V or ground of the I/O terminal or the external supply. 3 Check the quality and quantity of cooling air (See Chapter 5.2 and Table 5-6).. The 8 Tel: Fax:

85 commissioning vacon 83 4 Check the inside of the inverter for condensation. 5 Check that all Start/Stop switches connected to the I/O terminals are in Stop position. 6 Connect the inverter to DC supply. 7 Set the parameters of group 1 according to the requirements of your application (See Vacon All in One Application Manual). At least the following parameters should be set: motor nominal voltage motor nominal frequency motor nominal speed motor nominal current You will find the values needed for the parameters on the motor rating plate. 8 Perform run test without motor Perform either Test A or Test B: A Controls from the I/O terminals: Turn the Start/Stop switch to ON position. Change the frequency reference (potentiometer) Check in the Monitoring menu M1 that the value of Output frequency changes according to the change of frequency reference. Turn the Start/Stop switch to OFF position. B Control from the control keypad: Change the control from the I/O terminals to the keypad as advised in Chapter Press the START button on the keypad START. Move over to the Keypad control menu M3 and Keypad Reference submenu (see Chapter ) and change the frequency reference with the Browser buttons + -. Check in Monitoring menu M1 that the value of Output frequency changes according to the change of frequency reference. Press the STOP button on the keypad STOP. 24-hour support: +358-(0) vacon@vacon.com 8

86 84 vacon commissioning 9 Run the start-up tests without the motor being connected to the process. If this is not possible, make sure that running each test is safe prior to running it. Inform your coworkers of the tests. Switch off the DC supply voltage and wait until the drive has stopped as advised in Chapter 8.1, step 5. Connect the motor cable to the motor and to the motor cable terminals of the inverter. Make sure that all Start/Stop switches are in Stop positions. Switch the supply voltage ON Repeat test 8A or 8B. 10 Connect the motor to the process (if the start-up test was run without the motor being connected) Before running the tests, make sure that this can be done safely. Inform your co-workers of the tests. Repeat test 8A or 8B. 8 Tel: Fax:

87 fault tracing vacon FAULT TRACING When a fault is detected by the inverter control electronics, the drive is stopped and the symbol F together with the ordinal number of the fault, the fault code and a short fault description appear on the display. The fault can be reset with the reset button on the control keypad or via the I/O terminal. The faults are stored in the Fault history menu M5, which can be browsed. The table below contains all the fault codes. The fault codes, their causes and correcting actions are presented in the table below. Shadowed faults are A faults only. The items in white on black background present faults for which you can program different responses in the application, see parameter group Protections. Fault Fault Possible cause Correcting measures code 1 Overcurrent Inverter has detected too high a current (>4*I n ) in the motor cable: sudden heavy load increase Check loading. Check motor. Check cables. short circuit in motor cables unsuitable motor 2 Overvoltage The DC-link voltage has exceeded the limits defined in Table 4-3. Set the deceleration time longer. Add a brake chopper or a brake resistor. too short a deceleration time high overvoltage spikes in supply 3 Earth fault Current measurement has detected that the sum of motor phase current is not zero. insulation failure in cables or motor Check motor cable and motor. 5 Charging switch The charging switch is open, when the START command has been given. faulty operation component failure 6 Emergency stop Stop signal has been given from the option board. 7 Saturation trip Various causes: component failure brake resistor short-circuit or overload 8 System fault component failure faulty operation Note the exceptional Fault data record. See Undervoltage DC-link voltage is under the voltage limits defined in 4-3. most probable cause: too low a supply voltage inverter internal fault 10 Input line supervision Input line phase is missing. Reset the fault and restart. Should the fault re-occur, contact the distributor near to you. Cannot be reset from the keypad. Switch off power. DO NOT RE-CONNECT POWER! Contact factory. If this fault appears simultaneously with Fault 1, check motor cables and motor Reset the fault and restart. Should the fault re-occur, contact the distributor near to you. In case of temporary supply voltage break reset the fault and restart the inverter. Check the supply voltage. If it is adequate, an internal failure has occurred. Contact the nearest Vacon distributor. Check supply voltage and cable. 24-hour support: +358-(0) vacon@vacon.com 9

88 86 vacon fault tracing Fault Fault Possible cause Correcting measures code 11 Output phase Current measurement has detected that Check motor cable and motor. supervision there is no current in one motor phase. 12 Brake chopper supervision 13 Inverter undertemperature 14 Inverter overtemperature no brake resistor installed brake resistor is broken brake chopper failure Heatsink temperature is under 10 C Heatsink temperature is over 90 C or 77ºC (NX_6, FR6). Overtemperature warning is issued when the heatsink temperature exceeds 85 C (72ºC). Check brake resistor. If the resistor is ok, the chopper is faulty. Contact the nearest Vacon distributor. Check the correct amount and flow of cooling air. Check the heatsink for dust. Check the ambient temperature. Make sure that the switching frequency is not too high in relation to ambient temperature and motor load. 15 Motor stalled Motor stall protection has tripped. Check motor. 16 Motor overtemperature Motor overheating has been detected by inverter motor temperature model. Motor is overloaded. Decrease the motor load. If no motor overload exists, check the temperature model parameters. 17 Motor underload Motor underload protection has tripped. 22 EEPROM checksum fault Parameter save fault faulty operation component failure 24 Counter fault Values displayed on counters are incorrect 25 Microprocessor watchdog fault faulty operation component failure 26 Start-up prevented Start-up of the drive has been prevented. 29 Thermistor fault The thermistor input of option board has detected increase of the motor temperature 31 IGBT temperature (hardware) IGBT Inverter Bridge overtemperature protection has detected too high a short term overload current 32 Fan cooling Cooling fan of the inverter does not start, when ON command is given 34 CAN bus Sent message not acknowledged. communication 36 Control unit NXS Control Unit can not control NXP Power Unit and vice versa 37 Device changed Option board or control unit changed. (same type) Same type of board or same power rating of drive. 38 Device added (same type) Option board or drive added. Drive of same power rating or same type of board added. Reset the fault and restart. Should the fault re-occur, contact the distributor near to you. Cancel prevention of start-up. Check motor cooling and loading Check thermistor connection (If thermistor input of the option board is not in use it has to be short circuited) Check loading. Check motor size. Contact the nearest Vacon distributor. Ensure that there is another device on the bus with the same configuration. Change control unit Reset Note: No fault time data record! Reset Note: No fault time data record! 9 Tel: Fax:

89 fault tracing vacon 87 Fault Fault Possible cause Correcting measures code 39 Device removed Option board removed. Drive removed. Reset Note: No fault time data record! 40 Device unknown Unknown option board or drive. Contact the nearest Vacon distributor. 41 IGBT temperature IGBT Inverter Bridge overtemperature protection has detected too high a short term overload current Check loading. Check motor size. 42 Brake resistor overtemperature Brake resistor overtemperature protection has detected too heavy braking 43 Encoder fault Note the exceptional Fault data record. See Additional codes: 1 = Encoder 1 channel A is missing 2 = Encoder 1 channel B is missing 3 = Both encoder 1 channels are missing 4 = Encoder reversed 44 Device changed (different type) 45 Device added (different type) 50 Analogue input (sel. signal range 4 to 20 ma) Option board or control unit changed. Option board of different type or different power rating of drive. Option board or device added Option board of different type or drive of different power rating added. Current at the analogue input is < 4mA. control cable is broken or loose signal source has failed Set the deceleration time longer. Use external brake resistor. Check encoder channel connections. Check the encoder board. Reset Note: No fault time data record! Note: Application parameter values restored to default. Reset Note: No fault time data record! Note: Application parameter values restored to default. Check the current loop circuitry. 51 External fault Digital input fault. 52 Keypad communication fault There is no connection between the control keypad and the inverter. Check keypad connection and possible keypad cable. 53 Fieldbus fault The data connection between the fieldbus Master and the fieldbus board is broken Check installation. If installation is correct contact the nearest Vacon distributor. 54 Slot fault Defective option board or slot Check board and slot. Contact the nearest Vacon distributor. 56 PT100 board temp. fault Temperature limit values set for the PT100 board parameters have been exceeded Find the cause of temperature rise Table 9-1. Fault codes 24-hour support: +358-(0) vacon@vacon.com 9

How To Use The Vacon 0 Machinery

How To Use The Vacon 0 Machinery vacon 0 machinery how would you like your ac drive today? easy adaptation for customer requirements The Vacon 0 Machinery is an extremely compact AC drive for machine builders in the power range from 0.25

More information

NXL HVAC & COMPACT USER S MANUAL

NXL HVAC & COMPACT USER S MANUAL NXL HVAC & COMPACT USER S MANUAL AT LEAST THE 11 FOLLOWING STEPS OF THE START-UP QUICK GUIDE MUST BE PERFORMED DURING THE INSTALLATION AND COMMISSIONING. IF ANY PROBLEMS OCCUR, PLEASE CONTACT YOUR LOCAL

More information

user's manual nxs/p frequency converters enclosures ip21 and ip54

user's manual nxs/p frequency converters enclosures ip21 and ip54 user's manual nxs/p frequency converters enclosures ip21 and ip54 2 vacon AT LEAST THE 10 FOLLOWING STEPS OF THE START-UP QUICK GUIDE MUST BE PERFORMED DURING THE INSTALLATION AND COMMISSIONING. IF ANY

More information

vacon nxs/p user manual wall-mounted drives standalone drives ac drives

vacon nxs/p user manual wall-mounted drives standalone drives ac drives vacon nxs/p ac drives user manual wall-mounted drives standalone drives PREFACE VACON 3 PREFACE Document ID: DPD00910D Date: 20.2.2015 ABOUT THIS MANUAL This manual is copyright of Vacon Plc. All Rights

More information

vacon nxl ac drives user manual multi-control application manual

vacon nxl ac drives user manual multi-control application manual vacon nxl ac drives user manual multi-control application manual AT LEAST THE 11 FOLLOWING STEPS OF THE START-UP QUICK GUIDE MUST BE PERFORMED DURING THE INSTALLATION AND COMMISSIONING. IF ANY PROBLEMS

More information

Vacon Plc is not responsible for the use of the frequency converters against the instructions.

Vacon Plc is not responsible for the use of the frequency converters against the instructions. AT LEAST THE 11 FOLLOWING STEPS OF THE START-UP QUICK GUIDE MUST BE PERFORMED DURING THE INSTALLATION AND COMMISSIONING. IF ANY PROBLEMS OCCUR, PLEASE CONTACT YOUR LOCAL DISTRIBUTOR. Start-up Quick Guide

More information

vacon 100 vacon 100 flow vacon 100 hvac ac drives installation manual wall-mounted drives

vacon 100 vacon 100 flow vacon 100 hvac ac drives installation manual wall-mounted drives vacon 100 vacon 100 flow vacon 100 hvac ac drives installation manual wall-mounted drives PREFACE VACON 3 PREFACE Document ID: DPD01711F Date: 8.7.2015 ABOUT THIS MANUAL This manual is copyright of Vacon

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

vacon 100 ac drives installation manual

vacon 100 ac drives installation manual vacon 100 ac drives installation manual vacon 0 INDEX Document: DPD00390D Version release date: 27.1.11 1. Safety... 4 1.1 Danger... 4 1.2 Warnings... 5 1.3 Earthing and earth fault protection... 6 1.4

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS

HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS SPECIFICATIONS PRODUCT DATA Mains Connection Input voltage U in 380 500 Vac (±10%), 3~ Input Frequency 45 66 Hz Connection to mains Once per minute

More information

vacon 100 hvac ac drives installation manual

vacon 100 hvac ac drives installation manual vacon 100 hvac ac drives installation manual vacon 1 TABLE OF CONTENTS Document: DPD00926G Order code: DOC-INS02234+DLUK Rev. G Version release date: 25.9.13 1. Safety... 4 1.1 Danger... 4 1.2 Warnings...

More information

9000X AF Drives. User Manual. May 2011 Supersedes June 2009

9000X AF Drives. User Manual. May 2011 Supersedes June 2009 9000X AF Drives User Manual May 2011 Supersedes June 2009 9000X AF Drives Disclaimer of Warranties and Limitation of Liability The information, recommendations, descriptions, and safety notations in this

More information

vacon compact ac drives creating perfect harmony

vacon compact ac drives creating perfect harmony vacon compact ac drives creating perfect harmony what is harmony? We see harmony as a state of balance. The feeling that the solution created is the best possible for your specific needs. That the supplier

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

vacon nx ac drives active front end unit (afe) user manual

vacon nx ac drives active front end unit (afe) user manual vacon nx ac drives active front end unit (afe) user manual vacon 1 TABLE OF CONTENTS Document: DPD00906B Rev. B Version release date: 18.5.15 1. Safety...5 1.1 Warnings...6 1.2 Safety Instructions...6

More information

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

VLT Series 3500 Adjustable Frequency Drive Instruction Manual Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software

More information

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual HTL Encoder Interface FEN-31 ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

ST Series POWER SUPPLIES USER INSTRUCTIONS

ST Series POWER SUPPLIES USER INSTRUCTIONS Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional

More information

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. 7I29 MANUAL Rev 1.5 CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. THE 7I29 IS INTENDED FOR USE BY OEMS THAT WILL INTEGRATE IT INTO A SYSTEM WITH INTERLOCKS AND

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC

More information

vacon 100 hvac premium ac drive for indoor climate control

vacon 100 hvac premium ac drive for indoor climate control vacon 100 hvac premium ac drive for indoor climate control 1 vacon in brief Vacon is a leading supplier of variable-speed AC drives. Vacon is driven by a passion to develop, manufacture and sell only the

More information

vacon compact ac drives creating perfect harmony

vacon compact ac drives creating perfect harmony vacon compact ac drives creating perfect harmony creating perfect harmony Drives help improve the control of machines and increase energy efficiency. Selecting the right AC drive is, however, more than

More information

DLP-PU/E Instruction Manual

DLP-PU/E Instruction Manual Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS

More information

VSD Series Drives. November 2009 Supersedes September 2006. Powered by Eaton Technology. User Manual

VSD Series Drives. November 2009 Supersedes September 2006. Powered by Eaton Technology. User Manual Powered by Eaton Technology VSD Series Drives User Manual Supersedes September 2006 LIT-1201828 For more information visit: www.johnsoncontrols.com Powered by Eaton Technology VSD Series Drives User Manual

More information

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5 AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

vacon 100 x & vacon 20 x decentralized ac drives

vacon 100 x & vacon 20 x decentralized ac drives vacon 100 x & vacon 20 x decentralized ac drives maximum protection wherever you want Decentralized drive solutions enable engineers and machine designers to save on costs and space. VACON 100 X and VACON

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

TIG INVERTER INSTRUCTION MANUAL

TIG INVERTER INSTRUCTION MANUAL TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4

More information

vacon 100 hvac for indoor climate control

vacon 100 hvac for indoor climate control vacon 100 hvac for indoor climate control it s efficiency that counts Vacon 100 HVAC is designed to meet and exceed even the stringent requirements of the building automation industry. Easy installation,

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description

More information

A1000 Cheat Sheet (Open Loop Vector)

A1000 Cheat Sheet (Open Loop Vector) A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to

More information

NXL Series Inverters. HVAC Inverters made simple

NXL Series Inverters. HVAC Inverters made simple NXL Series Inverters HVAC Inverters made simple Honeywell s Voice Of the Customer process unveils a range of requirements expressed by specifiers and installers, that are ideally covered by the NXL inverter

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models TML Series, 0 & 0 Watt Features C B Scheme LVD UL 090- Encapsulated power supplies with increased power density Replaces TML and TML 0 series PCB mount or chassis mount with screw terminals Single, dual

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Manual Ranging MultiMeter

Manual Ranging MultiMeter Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

Analog Servo Drive 25A8

Analog Servo Drive 25A8 Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information

TAKEDO -3VF V20 INSTRUCTION MANUAL. www.sms.bo.it 3 18-10-2013. REL. DATE T.M. Check and Approval

TAKEDO -3VF V20 INSTRUCTION MANUAL. www.sms.bo.it 3 18-10-2013. REL. DATE T.M. Check and Approval TAKEDO -3VF V20 INSTRUCTION MANUAL 3 18-10-2013 REL. DATE T.M. Check and Approval www.sms.bo.it PAGE INTENTIONALLY LEFT BLANK 1 INTRODUCTION TAKEDO-3VF V20 is a new type of drive with built-in EMC filter,

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

Installation and safety instructions for AC/DC built-in devices

Installation and safety instructions for AC/DC built-in devices The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further

More information

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................

More information

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal

More information

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year

More information

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry. The perfect solution for basic servo applications Brochure May 2011 SINAMICS Answers for industry. with 1FL5 servomotors The solution for basic servo applications There is a requirement to automate motion

More information

Frequency Converter Fv

Frequency Converter Fv 2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)

More information

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

AutoRanging Digital MultiMeter

AutoRanging Digital MultiMeter Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

650W Single Output Power Supply

650W Single Output Power Supply AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent

More information

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives

More information