American Magnetostrictive Technology. Controller with software designed for China. IP68 Submersible Rating
|
|
|
- April Stevenson
- 9 years ago
- Views:
Transcription
1 American Magnetostrictive Technology Controller with software designed for China IP68 Submersible Rating
2 AMETEK Partners with RTI Management Groups on Tank Gauging System for China Market System Combines Proven Sensor Technology for China Market CLAWSON, MI AMETEK Automation and Process Technologies, a world leader in level measurement instruments, has established a strategic Business Partnership with RTI Management Group to develop a new Automatic Tank Gauging (ATG) System. The new ATG system combines the field-proven reliability of AMETEK s Series 7100M PetroStik patented level sensor technology with AMETEK and RTI patented RTL series consoles. The result is a unique continuous tank level gauge with user-friendly controls configured specifically for the Chinese retail gasoline station market. In addition to superior performance, the RTI ATG system is competitively priced with other high-resolution leak protection systems. For more information on the Patriot ATG System, contact: Wang Xiaolong RTI Management Group RM106 Tower A Huanzhan International Building 12 Yumin Rd. Madian Chaoyang District Beijing, PR China Tel: Michael Geis AMETEK Automation & Process Technologies 1080 N. Crooks Rd. Clawson, MI USA Tel: Fax: AMETEK Beijing Representative Office Room 2305, CITIC Building 19 Jianguomenwai, Dajie Beijing, , P.R. China Tel: Fax: Michael Geis Director of Business Development AMETEK Sensor Technology
3 AMETEK, Inc. PROFILE AMETEK is a leading global manufacturer of electronic instruments and electronic motors. The company has 8,000 employees with sales revenue over $1.2 billion. About 30% of AMETEK s products are sold out of the United States. The company has 50 manufacturing plants all around the world. AMETEK has been listed in the NYSE since 1930 (Ticker: AME). AMETEK s electronic instrument group has been developing and manufacturing the PATRIOT brand magnetostrictive liquid level probes for 15 years. The PATRIOT magnetostrictive probes are used by 11 liquid level gauge controller manufacturers all around the world, taking 20% of the worldwide market. In addition, AMETEK Automation & Process Technologies manufactures a wide range of position sensors including rotary cam limit switches, programmable limit switches, linear position sensors and rotary encoders; programmable controller bus cards including ultra-high speed programmable limit switches and electronic encoders for linear and rotary inputs; stamping press automation including shut height monitors; specialty products including cable and hose carrier systems. Point level sensor products including conductivity sensors, conductivity relays and magnetic probes; continuous level sensors including magnetostrictive probes for tank gauging and leak monitoring. PARTNERSHIP AMETEK has teamed up with RTI Management Group as our master distributor in China. Since its inception, RTI has participated in a series of power plant projects in China. The largest order was over $10 million dollars. Since 1997, the company started to expand its market into the petroleum and petrochemical industry, specializing in manufacturing and distribution of retail oil related instruments and accessories. It has won several of Sinopec s Automatic Tank Gauging System contracts. 1
4 Integrated Gas Station Management System Gas Station Corporate Gas Station Gas Station Gas Station Subsidiary Supply and Logistics Center RTS.NET management software works under the WINDOWS operating system. It gathers supply, sales and storage data of gas stations through telephone lines or intranets. The major functions of the software are as follows: Analyzes the collected data and generates reports Real-time measurement and management of individual gas station s oil level, water level, temperature, inventory and more. PATRIOT RTS Remote Management Software 2
5 Gas Station Supply-Sales-Storage Management Software RTS management software works with the RTL controllers under the WINDOWS operating system, managing the supply, sales and storage data of multiple gas stations. The key functions of the software are as follows: Can be connected with all kinds of RTL controllers, as well as other controllers Can display data such as fuel level, water level, temperature, storage level and head space of 8 or 16 tanks Automatically collects data and prints reports Fuel level and water level alarm function Static and dynamic leak detection Can transfer data through intranet or internet Records alarms Gas Station Supply-Sales-Storage Process Daily Inventory Report Volume Records at Shift Change Gas Station Data Management Shift Change Receiving Fuel Sales Gas Station Receipt Record Storage Record Discharge Record Gas Station Daily Sales Report Monthly Sales Report Annual Sales Report Loss and Gain Analysis Strapping Leak Detection Clean the Tank Other Loss and Gain Report Alarm Record Alarm Daily Sales Report to Corporate Inventory Report Sales Report Loss and Gain Analysis 3
6 Magnetostrictive level gauges are composed of a float, transducer and conductive tube. After the transducer is powered up, it sends a current pulse down the magnetostrictive wire. The current pulse creates a magnetic field and the interaction of this magnetic field with magnetic field created by a permanent magnet in a movable float produces a torsional strain pulse on the wire. The strain pulse then travels in both directions from the point of interaction. The strain pulse traveling up the THEORY Magnetostrictive Level Gauge ADVANTAGES wire is sensed by a small induction pick-up coil on the electronic circuit board sealed in the sensor tube. The strain pulse traveling down the wire is reflected off the patented bottom reflector. The time difference between sending out the initial pulse and receiving the torsional pulse is converted into the distance between the float magnet and the bottom of the probe (see illustration). Temperature measurement is achieved by placing temperature sensors along the tube. High current (2 amp, 60 volt) interrogation pulse creates electromagnetic field along Magnetostictive wire Strikes field of permanent magnet and creates a torsional strain pulse or wave guide twist, "like plucking a guitar string"... Permanent Magnet in Float...causing two torsional strain pulses to travel in each direction along wire (the wave guide) at approximately the speed of sound. Reflector t 1 t 2 Pulse Reaction Pulses Patriot 7100M Series Magnetostrictive Level Gauge Multifunctional measure oil level, water level and temperature Long service life Reliable performance IP68 rated, measures both oil and water Easy installation compact electronics package High resolution oil level: 0.25mm, water level: 1mm, temperature: 0.01 C Ideal for harsh environments 316L or PVDF housing Intrinsically safe UL, ATEX and CEC certified Available in various lengths up to 50 feet t 1 t 2 Time between initial pulse t 1 and second t 2 reflected return pulse is used to determine float posiiton and level. Permanent Magnet in Float t 2 t 2 - t 1 2 AMETEK 7100M Assembly Line Reflector Magnetostrictive Level Gauge Theory 4
7 SPECIFICATIONS Model 7100M-R5/R1 7100V Process Variables Fuel Level, Water Level, Temperatures Measurement 7 m 15 m Range Resolution mm 0.05mm Repeatability 0.006mm mm Linearity 0.25mm 0.5 mm Water Level 1 mm 2 mm Accuracy Leak Detection (l/hr) Temperature Measurement Resolution (±) +/ C (±) +/ C Operating 1.03 MPa Pressure Range Operating Range -20 C ~ + 70 C Ambient -40 C ~ + 70 C Temperature Range Input Voltage 26VDC ± 10% Sensor Output Pulse Position Modulated, Proprietary Protocol Approvals UL Class I, II, III; Div.1, C, D, E, F, G; ATEX Zone 0, Intrinsically safe Environment IP68; NEMA6 Probe Material 316 Stainless Steel PVDF Kynar Float Size 3 /4 polyurethane; 2 to 8 SS Float Material Polyurethane, 316SS, PVDF, Nitrophyl Applications Type 7100M Ethanol Gasoline, Gasoline, Diesel, Alcohol Contact factory for chemical compatibility Measurement Length Total Length PAT1(2) m 0.86m PAT1(2) m 1.17m PAT1(2) m 1.47m PAT1(2) m 1.78m PAT1(2) m 2.08m PAT1(2) m 2.39m PAT1(2) m 2.69m PAT1(2) m 3.00m PAT1(2) m 3.30m PAT1(2) m 3.61m Level Gauge Floaters Level Gauge Probes 5
8 MODELS Model RTL-500 RTL-68K-B RTL-68K RTL-760A # of Tanks /16 Accuracy 128 Point 50 Point 50 Point 300 Point Display 30 x 150 English N/A Chinese Touch Screen Printer Optional Instant Standard Optional Messaging Relay Output Protocol Temperature Compensation Static Leak Detection Optional Dynamic Leak Optional Optional Optional Detection Sensor 8 8 Automatic Alarm Power 220VAC ± 10% Environment Indoor RTL-68K RTL-68KB RTL-500 RTL-760A 6
9 MODELS Model RTL-760B RTL-800 RTL-880 # of Tanks 8/16 8 8/16 Accuracy 300 Point 300 Point 300 Point Display Touch Screen Color Touch Screen Color Touch Screen Printer Standard Instant Standard Standard Optional Messaging Relay Output Protocol Temperature Compensation Static Leak Detection Dynamic Leak Optional Optional Optional Detection Sensor Automatic Alarm Power 220VAC ± 10% Environment Indoor RTL-760B RTL-800B RTL-880A 7
10 INSTALLATION Wiring of the System RS232 RS232 Modem Modem RS232 Non-Hazardous Area Controller Hazardous Area Green Black White Product Float Level Gauge Ground Water Float Wiring of the Gas Stations Controller RS232 Wire Conduit Controller Room Access Explosion Proof Connection Box Nozzle 8
11 INSTALLATION Wire to the Control Room Seal (Included) 1/2-14NPT 600 mm Stainless Steel Flange Steel Tube Inner diameter greater than 100mm Requirements for Installing the 7100M Level Gauge The distance between the explosion-proof connection box and the nozzle is suggested to be greater than 200 mm Both ends of the explosionproof connection box have to be sealed, in order to prevent the vapors from going into the control room The grounding wire of the system has to be dedicated and be connected to the main ground of the gas station The wires of the probe need to be separated from other wires and protected by individual sheath The wires should be run through conduits. Both the conduit and the grounding wire of the probe (the green wire) have to be grounded. The cross-section area of the grounding wire has to be greater than 2mm. The entire system has to be grounded at the same point. Float Water 210 mm Probe Float Float Specifications of the wires are as follows: Capacitance: less than 60PF/inch Inductance: less than 0.2 uh/inch Circumventing: greater than 8 rotations/inch Stainless Steel Flange 9
12 COMPONENTS Pressure Vacuum Valve 2"-3" size 8OZ relief pressure / 5OZ relief pressure 8000 inch 3/hour NPT thread / 0 push fit Emergency Shut-Down Valve 1.5" NPT size OUT: internal thread/ external thread/ hose connection IN: 2" internal hose / 2.3/8" hose clamp Vapor Recovery Connection One-way valve Male/Female trough Internal thread Vapor Recovery System Vapor Recovery System Vacuum pump Soft tube Valve Nozzle Over-fill Prevention Valve 4" size Fast fill High level alarm at 99% capacity Float Valve Over-fill prevention settings 2" internal thread Prevent fuel from being mixed Prevent over-fill 12"/16"/21" Vapor Recovery Pump The vapor recovery pump is empowered by conveying tape or motor. The mounting of the pump can be adjusted to specific needs of customers. Vapor Recovery System Vapor recovery system is composed of nozzle, vacuum pump, oil tube and oil-vapor separating device. Emergency Shutdown Valve In the event of a fire or impact, the emergency shutdown valve will engage to prevent spillage. Nozzle Advantages: Light weight Long life Large capacity Easy to adjust 10
13 Over-fill Prevention Valve, Float Valve, Vacuum Pump The new over-fill prevention valves are mounted on the 4 under ground tanks. The advantages of this valve are: fast speed, small resistance, and high-level alarm at 99% capacity. Compared to similar products, it reduces vibration of the tube. Flexible Pipe Lifetime of these pipes is over 20 years Pump Manually relief pressure: To maintain, open the pressure relief tap to bring the pressure to zero. The oil in the pump will flow back into the tank. Advantages: Well lubricated to enhance lifetime. Compound Fiber Man Way Cover The compound fiber man way cover is very light. The fiber material is tested to be better than the D.O.T.H-20 weighing standard. The lightweight man way cap weighs only 1/3 of similar sized steel cap and consequently makes the process safer. We offer three standards: 30, 36 and 42. The mechanical design does not require people to bend down in order to move the cap. 11
14 CERTIFICATES UL Certificate PEI Certificate 12
15 IP68 Rated CEC Certificate
16 Automatic Tank Gauging System Automation and Process Technologies Wang Xiaolong RTI Management Group RM106 Tower A Huanzhan International Building 12 Yumin Rd. Madian Chaoyang District Beijing, PR China Tel: [email protected] Michael Geis AMETEK Automation & Process Technologies 1080 N. Crooks Rd. Clawson, MI USA Tel: Fax: AMETEK Beijing Representative Office Room 2305, CITIC Building 19 Jianguomenwai Dajie Beijing, , P.R. China Tel: Fax: , by AMETEK, Inc. All rights reserved. (260004)
Qingdao Guihe Measurement&Control Technology Co., Ltd. Automatic Tank Gauging System, Magnetostrictive Diesel fuel tank level gauge
Automatic Tank Gauging System Magnetostrictive Liquid Level Meter (Tank gauging system) for gas stations produced by Guihe consists of Probe and Touch Control Console. There are different plans to satisfy
Automatic tank gauge system ATGs for petrol stations, diesel fuel tank level gauge, tank gauging system, magnetostrictive probe
Fuel tank level gauge consist of Magnetostrictive probe (mode:syw-a, SYW-A1)and Touch screen control console (mode:tcm-1,tcc-3). SYW-A magnetostrictive probe installed in the tank, with magnetostrictive
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
Morrison Bros. Co. General Product Specifications
Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage
1/2 NPTM. 29.21 mm 1.15. Nose cone fitting Ideal for clean liquids
PT-500 Submersible Liquid Level Transmitter 1.0 Hex 25.4 mm 7.0 177.8 mm Re-Usable cage fitting Ideal for dirty liquids 5.63 143 mm 5.33 136 mm 1/2 NPTM 3.5 88.9 mm 1.15 29.21 mm Nose cone fitting Ideal
Tank Gauging & Inventory Management Solutions
& Inventory Management Solutions Automation solutions for oil & gas, defense and aviation applications FuelsManager, Varec s industry-leading software is available in four editions: Standard, Professional,
Automatic Tank Gauging System, magnetostrictive liquid level meter, diesel fuel gasoline tank level gauge, fuel level sensor probe, fuel level measuring instrument
Automatic Tank Gauging System Magnetostrictive Liquid Level Meter (Tank gauging system) for gas stations produced by Guihe consists of Probe and Touch Control Console. There are different plans to satisfy
DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
Tank Gauging Products for Bulk Liquid Storage Tanks. Simple, Safe and Reliable Inventory Measurement
Products for Bulk Liquid Storage Tanks 2500 Automatic Tank Gauge The industry standard for float and tape tank gauging for over 50 years Provides a level accuracy of 0.2-1 inch (4-25 mm) Continuous level
Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
Float & Tape Tank Gauging Solutions for Bulk Liquid Storage Tanks. Simple, Safe and Reliable Inventory-Grade Level Measurement
Float & Tape Tank Gauging Solutions for Bulk Liquid Storage Tanks Simple, Safe and Reliable Inventory-Grade Level Measurement Varec Float & Tape - Automatic Tank Gauging www.tankgauging.com The Varec brand
key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100
Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When
4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems
Dynamic Solutions Leadership and Innovation in Valve Products and Valve Systems At ASCO, Valve Performance Begins and Ends With People 4 First of all, it begins with the people we serve. It is from them
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Practical Application of Industrial Fiber Optic Sensing Systems
Practical Application of Industrial Fiber Optic Sensing Systems John W. Berthold and David B. Needham Davidson Instruments, Inc. P.O. Box 130100, The Woodlands, TX 77393 ABSTRACT In this presentation,
Explosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
Model 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
Table of Contents. TransformerIQ FAQs 1
[12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is
B-Series Temperature Switches
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment
TECHNICAL PAPER. Magnetostrictive Level Sensors. Liquid Level Sensors. Theory of Operation. David Nyce and Adrian Totten
l MTS Systems Corporation Sensors Division 3001 Sheldon Drive Cary, NC 27513 Phone 919-677-0100, Fax 919-677-0200 TECHNICAL PAPER Part Number: 08-02 M1166 Revision A Magnetostrictive Level Sensors David
SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE
Series Circuit Breaker Monitors CONSOLIDATED Electronics, Inc. MONITORING THE FUTURE Why SF Gas Density Monitors? 6 Cut Maintenance Costs Your capital investment may be recovered with the elimination of
8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
DC400 Dispensing Cutoff System
DC400 Dispensing Cutoff System DC404 and DC406 Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com
Isolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
The Do s and Don ts of Pressure Transducers
The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed
SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS
1/3 & 3/4 Hp Fixed Speed Submersible Turbine Pumps Marketers concerned about fueling times, efficiency, serviceability, reliability and overall quality find it an easy choice to specify FE Petro brand
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.
Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration
Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS
EPP - 1 DECRIPTION The odel 575 is used in general water/wastewater applications. The transmitter is offered in a standard non-clogging snub nose end, flush diaphragm or protected flush diaphragm with
Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual
Operation and Maintenance Manual Introduction Read all instructions thoroughly. Installation of the OilTector must comply with all Federal, State and Local Codes, Regulations and Practices. The OilTector
VEGAPULS PULSE RADAR FOR LEVEL MEASUREMENT VEGAPULS 60 SERIES
VEGAPULS PULSE RADAR FOR LEVEL MEASUREMENT VEGAPULS 60 SERIES Why Use RADAR? Are you tired of re-calibrating the 0-point on pressure transmitters or dp cells? Operating by using electromagnetic microwave
Screw Plug Immersion Heaters
Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters
Excellence through Versatility
Metering Pumps Excellence through Versatility Liquid Metronics Incorporated has been providing quality products and service to the water treatment industry worldwide for over 25 years. Leading the way
UST RULES CHANGES. Heather Peters, Environmental Specialist
UST RULES CHANGES Heather Peters, Environmental Specialist Today s Topic 2011 Rule package- what s left? Upcoming rule changes Federal Regulation Changes & Testing Protocols How are you doing? 2011 Rule
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
ATL Fuel Level Sender Probes
T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Spill Containment Manholes
Spill Containment Manholes 1-2100 Series OPW and Pomeco Spill Containment Manholes are designed to prevent spilled product from entering the soil near the fill and vapor return riser connections on underground
The Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits
Diesel Engine Air Intake Shutoff Valves Model RDS1 Swing Gate Valve Overview If flammable gas or vapor is present in the atmosphere surrounding a diesel engine, it can be ingested into the engine and become
Industrial Strength Leak Detection
Industrial Strength Leak Detection Don t let an undetected leak or spill ruin the environment or your reputation... TraceTek Technology: Find leaks before major damage is done... TraceTek Technology: Sensors
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring
LNG Monitoring Fiber-Optic Leakage Detection System Pipeline leakage detection Regasification and liquefaction monitoring Tank annulus and base slab monitoring Spill containment control Intelligent Solutions
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer
PT-400 Heavy Duty, Amplified Output Pressure Transducer C US The PT-400 offers high accuracy and reliability over a wide range of pressures. The small size, integrated electronics, wide operating temperature
API Marine. BMS Presentation. Ballast Measurement Systems
API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.
B-Series Switches Pressure, Differential Pressure & Hydraulic
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment
BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)
CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted
SELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE
A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE The U.L.C. Listed C142.14-03 Cubet container provides a unique solution to storage and dispensing fluids. The Cubet s logical and integrated design allows
KNC Model 3666 Automatic Pressure Calibration System
KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory
LHD LINEAR HEAT D ETECTIONN
Tri-Metallic Core: Steel provides tensile strength Copper increase conductivity Tin for corrosion resistance LHD LINEAR HEAT D ETECTIONN TECHNICAL DATA Temperature Rating: 155 F (68 C) (typical temperature)
Ethanol-Water Phase Separation White Paper
Ethanol-Water Phase Separation White Paper Samir Jain Background The use of ethanol as a fuel in the United States has significantly increased over the past decade. Today, greater than 80% of all retail
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown
Self-Regulating 920 Series Dual-point heat-tracing control system Power-Limiting Mineral Insulated 920*E4FWL*SIS302*SS3102 shown Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based,
P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps
P/N: DEF-0613A Diesel Exhaust Fluid (DEF) Pumps DEF Solutions Standard Pump has designed a range of unique, preconfigured DEF Pump Packages that are engineered to transfer AdBlue (AUS32) Diesel Exhaust
TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output
133-683 JUNE 28, 2006 TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output DESCRIPTION APPLICATION The Fireye 65UV5-1004 flame scanner is a microprocessor based flame
The L&J Engineering Model MCG 1500SFI Servo Gauge
PRODUCT DATA SHEET The is the most compact and lightest servo available today. Accuracy / repeatability of 1/32 inch (0.8mm) Product and Interface, custody transfer Wireless Infrared Calibration Advanced
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com
OUR PARTS PUT YOU IN THE PASSING LANE FUEL SYSTEMS Protect your fuel system. Velvac offers a wide range of locking fuel caps and anti-siphon tubes to keep unlawful occurances at bay. With OEM approved
Series 510 Submersible Level Transmitters
Series 510 Submersible Level Transmitters The Series 510 Submersible Level Transmitters are solid state instruments designed for direct submergence into many types of liquid for quick, accurate and reliable
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank This specification describes requirements for a Diesel Fuel Day Tank System consisting of one or more fuel tanks, an Electronic
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Hydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
Fluid Monitoring and Inventory Management
SECTION FOUR Fluid Monitoring and Inventory Management Introduction Alemite meets your fluid monitoring and inventory management needs with its Accu-Guard systems and its Bigview Tank Monitor. These systems
EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
ISO 9001 Certified Manufacturing Facility SPECIFICATIONS
TS-250 Rev. 0-00-12-07 Refined Fuels PD Meters Size 2 Type 4-MT & 4D-MT 2 PETROLEUM AND LP-GAS TANK TRUCK METERS 2 4-MT with Air Release, Strainer, Printing Register and Preset Valve 2 4D-MT with Vapor
Turbine Flowmeters for Gas Applications
Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because
Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems
Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems The measurement of temperature is critical in the determination of the true volume of product in a hydrocarbon
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
Automatic Fire Fighting Monitors
Automatic Fire Fighting Monitors Fire Protection Solutions Automatic Fire Fighting Monitors Foreword Automatic monitors are devices used to deliver large amounts of water or water/foam solution to remote
Protection Systems. A UTC Fire & Security Company F-73-01. Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS
Effective: May 2007 AlarmLine TM R Protection Systems Linear Heat Detector A UTC Fire & Security Company F-73-01 FEATURES Integrating Type Linear Heat Detector Analog Sensing Field Adjustable Alarm Set
Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370
Pump_TM016 Pump Local Display TM0200 TM0200 4-20mA PLC/DCS Case 1 Pump Relay Output Module 4-20mA Optional PT371 Modbus PT373 Case 2 PCM370 TM016 Velocity/ Acceleration Vibration Transmitter Introduction
OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS
Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN
Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial
sect. 05 9600 rev. 206/08/0 Pressure Gage and Swichgage Instruments OPL Series 4-/2 in. (4mm) Diameter Dial The OPL-series pressure Swichgage instruments are combination pressure indicating gages with
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Electronic, Digital and Mechanical Vibration Switches
PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive
Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision J Features 4 to 20
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW
PROCESS AUTOMATION OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS Industrial Monitors And HMI Solutions PRODUCT OPERATING AND MONITORING wherever you want The Pepperl+Fuchs HMI
PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller
BLZPTS-1 NOVEMBER 19, 2013 TS350 TS752 BLPS PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller DESCRIPTION The BLPS, TS350
Medical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
SDX Submersible Depth Transmitter User Manual
SDX Submersible Depth Transmitter User Manual January 2011 USER INFORMATION Stevens makes no warranty as to the information furnished in these instructions and the reader assumes all risk in the use thereof.
3500/93 System Display
3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding