CS5000 Users Manual. Intercomp Co County Road 116 Medina MN U.S.A.

Size: px
Start display at page:

Download "CS5000 Users Manual. Intercomp Co. 3839 County Road 116 Medina MN 55340 U.S.A."

Transcription

1 CS5000 Users Manual Intercomp Co County Road 116 Medina MN U.S.A. (763) Fax: Manual#: V Page 1 of 31

2 Table of Contents INTRODUCTION... 3 SPECIFICATIONS... 3 Controls... 3 Electrical... 3 Performance... 3 Environmental... 3 Physical... 4 Radio... 5 PARTS AND OPTIONAL EQUIPMENT... 5 OPERATIONS... 7 DISPLAY (BASE)... 7 Indicators... 7 CONTROLS - HEAD (SCALE)... 7 ON... 7 CONTROLS - BASE (CONTROLLER)... 8 SETUP lb/kg Switching Setting time and date POWER/BATTERIES CALIBRATION HOW TO TEST THE CALIBRATION CALIBRATION SWITCH HOW TO CALIBRATE THE SCALE LEGAL-FOR-TRADE SEALING ERROR MESSAGES TROUBLESHOOTING PARTS AND ACCESSORIES PARTS LIST: 500 LB CAPACITY PARTS LIST: 2K LB CAPACITY PARTS LIST: 5K LB, 10K LB CAPACITY PARTS LIST: 20K LB, 30K LB CAPACITY SERIAL OUTPUT EXAMPLE CONNECTIONS HOW TO REACH INTERCOMP SERVICE "This document is the property of Intercomp Co. It contains material and information that is confidential and protected under federal and/or state trade secret, unfair competition, and copyright law. Any reproduction, use or disclosure without written permission from Intercomp Co. is prohibited". 2

3 Introduction This manual contains specifications, operation instructions, and calibration instructions for Intercomp's model CS5000 crane scale. Specifications Controls General: Head: Base: Display: Base: 5 ½ digit LED. Indicators: Head: Base: On (Base remotely turns the scale head off). On/Off,Zero, Print, Total, Display Total, Clear Total, Tare Set, Tare Display, Tare Clear. power. lb/kg, Tare, Net, Gross, On-screen Motion, Total. Electrical Batteries: 8 X D-size disposable alkaline dry cells or rechargeable (Base and Head) Nickel-Cadmium cells. Battery life: Up to 50 hours with alkaline batteries. Approximately 20 hours on a set of fully charged Ni-Cad cells. Resolution: 20 bit A/D delivers over 1,000,000 internal counts. Filtering: 6 Pole, 10 Hertz low pass. Auto off: Low battery, or after adjustable time without use or motion. Auto-Zero: Satisfies all HB-44 requirements; selectable 0.6, 1, or 3 graduations. Performance Accuracy: ±0.1% of applied load or ± display graduation, whichever is greater. Speed 2 readings / sec. Transmitting Range Up to 500 ft / 150 meters Environmental Humidity: 10 to 95% Non-Condensing Temperature: Storage: -40 C to +75 C. / -40 F to +170 F. Operating -10 C to +50 C. / +14 F to +122 F. 3

4 Physical * * * Capacity Graduation A B C D * Hook Eye nut or shackle 500 lb 0.2 lb in: C/L 3 ton C/L #7 250 kg 0.1 kg mm: S1 swivel eye nut 2,000 lb 1,000 kg 5,000 lb 2,500 kg 10,000 lb 5,000 kg 20,000 lb 10,000 kg 30,000 lb 15,000 kg 50,000 lb 25,000 kg 70,000 lb 35,000 kg 100,000 lb 50,00 kg 1 lb 0.5 kg 1 lb 0.5 kg 2 lb 1 kg 5 lb 2 kg 10 lb 5 kg 10 lb 5 kg 20 lb 10 kg 20 lb 10 kg in: mm: in: mm: in: mm: in: mm: in: mm: in: mm: in: mm: in: mm: The dimensions below are top to bottom shackle, eye to eye on ton / metric ton models C/L 3 ton S1 swivel C/L 5 ton S1 swivel C/L 5 ton S1 swivel C/L 10 ton S1 swivel C/L 15 ton S1 swivel C/L 25 ton S1 swivel C/L 35 ton S1 swivel C/L 45 ton S1 swivel C/L #7 eye nut C/L #7 eye nut C/L #7 eye nut C/L # 11 eye nut C/L # 11 eye nut C/L 40 ton #2140 C/L 40 ton #2140 C/L 50 ton #2140 Approx Weight 48 lb 22 kg 50 lb 23 kg 58 lb 26 kg 58 lb 26 kg 97 lb 44 kg 122 lb 55 kg 220 lb 100 kg 248 lb 113 kg 392 lb 178 kg 4

5 Radio Radio frequency (US/Canada) License requirements Range 2.4 GHz, FHSS, 50 mw output power None. Pre-approved US/FCC, CAN/IC, EUR/EN 200 / 60m indoor, 300 / 90m line of sight! WARNING: To satisfy FCC RF exposure requirements for mobile type transmitting devices, a separation distance of 20cm or more should be maintained between the antenna of this device and persons during operation, with the exception of hands, wrist, feet, and ankles. To ensure compliance, operations at closer distance than this is prohibited. Parts and Optional Equipment Oversized top lifting eye (100744) This part is applicable to 500 lb - 10,000 lb capacity models. Oversized top shackle (100745) This part is applicable to 20,000 lb and 30,000 lb capacity models. Oversized top shackle (100746) This part is applicable to 50,000 lb and 70,000 lb capacity models. Oversized top shackle (100747) This part is applicable to 100,000 lb capacity models. Anti heat shield (100720) Bottom plate with standard hook rated for Medium anti heat shield (100670) protection. Includes oversized hook and custom swivel. Extreme anti heat shield (100671) protection. Includes oversized hook and custom swivel. Remote load cell input and summing (100724) Load cell input with electronic summing board. An external load cell can be connected to the CS5000. The scale averages the signals from the 2 load cell outputs. RS232 Serial data output (100721) The CS5000 has an RS232 connection so the unit may communicate with a printer or computer. LED Display on crane unit (100725) Optional LED (light emitting diode) display on the head. An LED display is fully readable in pitch-dark lighting situations. 5

6 LCD Display on crane unit (100726) Optional LCD (liquid crystal display) display on the head. Anti-magnetic shielding (100722) Provides protection from high magnetic fields. Battery pack and 120V external charger (100730) Rechargeable Ni-Cad battery pack (8 D-cells) with 120V external charger. Standard power uses 8 disposable alkaline dry cells. Battery pack and 220V external charger (100731) Rechargeable Ni-Cad battery pack (8 D-cells) with 220V external charger. Standard power uses 8 disposable alkaline dry cells. Battery pack, Ni-Cad (100733) D size rechargeable battery pack (qty: 8). Direct Power on crane unit, 120V (100723) This option allows the CS5000 to use 120V power instead of batteries. Direct Power on crane unit, 220V (100727) This option allows the CS5000 to use 220V power instead of batteries. 6

7 Operations Display (Base) kg Optional: displays 1 or blank Gross Total Net lb Tare Indicators kg: Indicates the scale is weighing in kilograms. When lit, the scale is in kg mode. Press TOTAL DISPLAY and TARE DISPLAY together to toggle units. Total: Indicates that the current number displayed is the total. The net indicator will also be lit to represent that the total totalizes the net weights. lb: Indicates the scale is weighing in pounds. When lit, the scale is in lb mode. Press TOTAL DISPLAY and TARE DISPLAY together to toggle units. Gross: This indicator is lit when the display represents that the gross weight is being displayed. Net: This indicator is lit when a tare value is set and the weight shown is the calculated net weight. Tare: This indicator is lit while the tare weight is being displayed. Controls - Head (scale) ON Press this button to turn the scale on. 7

8 Controls - Base (controller) ON/OFF Press this button to turn the base unit on. The scale tests itself, then displays or HO-00 HO-00. When a weight is received from the scale head it will be displayed. Press this button again to turn the scale off. The head will turn off automatically. PRINT Pressing this key will output an RS-232 signal containing the Gross, Net, Tare, total weight, and the time and date. Note: The print key will only function when there is no motion. Also see the Serial Output' section in this manual. ZERO Tells the scale to display a zero weight. This button is used any time the scale shows a non-zero value with no weight on the hook. If you press ZERO with weight on the hook, that weight becomes the zero condition for the scale. This can be useful to cancel the weight of any weighing fixtures, such as containers, chains or cables. When this weight is removed, a negative weight shows until the system is zeroed again. NOTES: When ZERO is pressed, the CS5000 will display " " until a stable reading is taken. If there is continuous motion for more than 20 or 30 seconds, the zero command will be rejected and the scale will return to normal weighing. The scale contains a feature called Auto Zero Tracking (AZT), which corrects for slight zero changes during normal operation. If small weights are added slowly, the scale could zero them off. TARE Use this button to read a tare weight into memory. This tare weight will be subtracted from a gross weight, giving you the net weight. This is useful for canceling the weight of a container used in weighing. A segment on the right side of the display shows that the net weight is being calculated. NOTE: When TARE is pressed, the CS5000 will display "-----" until a stable reading is taken. If there is continuous motion for more than 20 or 30 seconds, the tare command will be rejected and the scale will return to normal weighing. 8

9 TARE DISPLAY You may press the TARE DISPLAY button to display the tare weight. Pressing the TARE DISPLAY button a second time will return to the gross or net display. TARE CLEAR This button is used to clear a stored tare weight to zero. TOTAL By pressing this button, the current net weight is added to the total. Note: If the tare weight is zero, the net weight is equal to the gross weight. TOTAL DISPLAY Pressing the TOTAL DISPLAY screen will switch the display to show the current total weight. Pressing the key a second time will return to normal weighing. TOTAL CLEAR Clears the total to zero. 9

10 Setup Use the following procedure to setup and weigh: 1: Hook CS5000 scale head onto hoist. 2: Turn on CS5000 scale head. 3: Turn on CS5000 base. 4: Hook any weighing fixtures onto CS5000 hook (chains, etc.) 5: Hook any weighing bin or platform onto CS5000 hook or fixtures. 6: Hoist into air so that it is free swinging. 7: Press ZERO on base. The CS5000 will wait for a stable zero reading. 8: Proceed with weighing. lb/kg Switching Press the TOTAL DISPLAY and TARE DISPLAY keys together to switch lb/kg. This toggles the weighing system between pound (English) and kilogram (SI metric) units of measure. The current unit of measure is shown by the left indicators of the CS5000 base (as shown in the section Display (Base) ). Setting time and date To set the time and date press the three keys labeled TARE, TARE DISPLAY, and TARE CLEAR together and release. The scale will then ask you to enter seven numbers representing the month, day, year, hour, minute, second, and am/pm. You increase the number by pressing the TARE DISPLAY button. When the number is set, pressing the TARE button moves on to the next number. When you have completed entry of all seven numbers press the TARE CLEAR button to exit and start the clock running. The numbers are displayed in the following format Hx-yy, were x is the number being set and yy is the value. The following chart shows the seven values and their ranges. Display Meaning Range H1-yy Month 1-12 H2-yy Day 1-31 H3-yy Year 0-99 H4-yy Hour 1-12 H5-yy Minutes 0-59 H6-yy Seconds 0-59 H7-yy am/pm 0-1 (0 = am, 1 = pm) If the year is set prior to '91 it will be displayed as 20xx. 10

11 Power/Batteries Head: Remove the two caps in the back of the CS5000 head. Tip the old cells out. Change the 8 D cells, being careful to put the positive end in first (The end with the bump). Replace the battery caps. Base: Loosen the 2 screws that latch the lid tight so the lid can be opened. Replace the 8 D cells, being careful to note the polarity indicated on the battery holders. Close lid and retighten the screws for the latches. You may use rechargeable 8 Nickel-Cadmium 'D' cells or 8 standard alkaline 'D' cells in the CS3000. Warning: If you have the optional charger, do not plug the charger in while there are standard D cells inside. This could result in damage to the batteries and your scale. The typical recharge time for Ni-cad cells is 16 hours. The rechargeable batteries have a life span up to 1000 cycles. 11

12 Calibration How to test the calibration This calibration procedure should be performed annually for normal operating conditions. If the scale is dropped or damaged, or service has been performed on the scale, use this calibration check. 1. Turn on the head and the base. The display does a lamp test; during this time the scale does a quick check of itself. Then the weighing system starts weigh mode. 2. Intercomp recommends that you allow the electronics to operate for three minutes after first turning power on. This allows the electronics to become stable for maximum accuracy before you check the calibrations. 3. Make sure no weight is on the hook. Press the ZERO button. Press the TARE CLEAR button to clear the tare. The weight shown is zero. 4. Apply weights throughout the weighing range, and verify the correct weight (+/- 0.1%) is displayed at each step. 5. If possible apply a weight of 105% of capacity, and verify the scale shows OE on the display. 6. Remove weights and verify the display returns to zero. 7. If there is a failure to meet any of the conditions above, please refer to the Calibration Procedure. 8. When all the conditions above are correct, the scale is operational. Calibration Switch The calibration of the scale is protected from accidental change by a switch protected by an access plug. The access plug is located on the front of the scale head above the ON switch, and is covered by a calibration sticker (seal). The switch is set in the calibration blocked mode at the factory. Enabling the Calibration switch First, remove the calibration sticker which covers the access plug. Using a ¼ Allen wrench, remove the access plug. Insert the Allen wrench in to the hole and press the switch once. The scale is now set to allow calibration. How to enter a number During this routine you will be asked to enter numbers at many points. You must use the ZERO and PRINT switches to enter these numbers. The scale will show 5 digits but there are actually 6 digits because the leftmost digit is initially invisible. The active digit will be blinking. Press the ZERO key to increase the value of the blinking digit. Press the PRINT key to move the blinking digit one place to the left. When you advance to the leftmost digit, the display will initially be blank (value of 0). This display segment can be toggled between 0 and 1. When you are finished entering the number press both the ZERO and PRINT switches simultaneously to go on. 12

13 Three point span The scale has a three point calibration feature which reduces the effects on non-linearity in the load cells. This requires that you place three weights on the cell during calibration. The first weight must be greater than zero, the second greater than the first, and the final weight somewhere between the second and the capacity. How to Calibrate the Scale There are three parameters that can be set without moving the calibration switch, followed by three more parameters and the actual calibration which require the calibration switch to be in the enabled position. Display Parameter Note Default Sample Rate 1 to 64 4 EE-00 EE-01 EE-02 Update Rate 1 to 32 4 Power up in kg 1=kg, 0=lb 0 Information saved Check for calibration blocking switch EE-03 EE-04 EE-05 LL-00 LL-01 LL-02 LL-03 AZT 0=off,1=0.6,2=1,3=3 2 Canadian Specifications 0=off, 1=on 0 Graduation 0 to 11 6 Information saved Zero read First weight Second weight Third weight Information saved Enter capacity Enter first weight Enter second weight Enter third weight 1. Access the calibration switch and press once if you intend to calibrate. See Calibration Switch. 2. Turn both the base and head on. Wait for scale to warm up (2-3 minutes). 3. Press ZERO and PRINT together and release to enter the calibration mode. 4. The scale displays EE-00 EE-00. Press the ZERO and PRINT keys simultaneously. Enter the sample rate (1 to 64), ('4' is suggested, although if your readout is too jumpy, you can increase this value). The sample rate is the number of past readings that are averages together to make a reading. (Press ZERO and PRINT keys to enter this number.) 13

14 5. The scale displays EE-01 EE-01. Press the ZERO and PRINT keys. Enter the display update rate (1 to 32), ('4' is suggested). The display update rate is the speed at which the display is updated, with 1 being the fastest. (Press the ZERO and PRINT keys to enter this number. 6. The scale displays EE-02 EE-02. Press the ZERO and PRINT keys. Enter what unit of measure the scale should operate in; pounds or kilograms (0 to 1). (Press the ZERO and PRINT keys to enter this number.) Setting Units to operate in 0 pounds (lb) 1 kilograms (kg) Note: At this point the changes you entered will be saved and the scale could be turned off if you don't wish to change the calibration. 7. The scale shows EE-03 EE-03. Press the ZERO and PRINT keys. Enter the desired AZT size. The AZT size is the number of graduations the auto zero tracking can remove. Note: At this point if the calibration blocking switch is not in the enabled position, the scale will not save the new AZT value. It will instead display the E1 E1 error message and return to normal weighing. See Calibration switch to change this. Setting AZT size 0 Off The scale shows EE-04 EE-04. Press the ZERO and PRINT keys. The scale shows the current Canadian specification selection. Use the following table to select the Canadian specifications setting. Setting Canadian Specification 0 Off 1 On A '0' setting implies normal operation: 1: AZT size is determined by setting of EE-03. 2: Zero operates over full range of capacity. 3: Over capacity is 103% from the zero obtained at calibration. A '1' setting implies Canadian specifications are used: 1: The AZT size fixed at 0.6d regardless of EE-03 setting. 14

15 2: The IZSM (initial zero setting mechanism on power up) must be within +/- 10% of the zero obtained at calibration. 3: The push-button zero and AZSM can only operate within +/- 2% of the IZSM. 4: The overcapacity point is 103% of capacity above the IZSM. 9. The scale shows EE-05 EE-05. Press the ZERO and PRINT keys. Enter the desired graduation. Use the following table to select a graduation value. (Press the ZERO and PRINT keys to enter this value.) Setting Count by Count by in lb in kg NOTE: To meet stated accuracy statements, it is suggested that you choose your graduation setting from the table below: If your capacity is: Set your graduation to: 500 lb / 250 kg 0.2 lb / 0.1 kg (8) 1000 lb / 250 kg 0.5 lb / 0.2 kg (7) 2,000 lb / 1,000 kg 1 lb / 0.5 kg (6) 5,000 lb / 2,500 kg 1 lb / 0.5 kg (6) 10,000 lb / 5,000 kg 2 lb / 1 kg (5) 20,000 lb / 10,000 kg 5 lb / 2 kg (4) 30,000 lb / 15,000 kg 10 lb / 5 kg (3) 50,000 lb / 25,000 kg 10 lb / 5 kg (3) 70,000 lb / 35,000 kg 20 lb / 10 kg (2) 100,000 lb / 50,000 kg 20 lb / 10 kg (2) Note: The changes will again be saved here and the scale could be turned off if you don't wish to change the calibration. 15

16 10. The scale displays LL-00 LL-00. Press the ZERO and PRINT keys. On the next screen enter the capacity, in the units (lb or kg) that you are calibrating in. With no weight on the hook, press the ZERO and PRINT keys to enter in this capacity. Max capacity is lbs. Special versions allow a max capacity of lbs. 11. The scale shows LL-01 LL-01. Apply the first weight and press the ZERO and PRINT keys. On the next screen enter the weight being applied. With the weight on the hook and its exact value shown on the CS5000 screen, press the ZERO and PRINT keys to enter in the weight. 12. The scale shows LL-02 LL-02. Apply the second weight and press the ZERO and PRINT keys. On the next screen enter the weight being applied. With the weight on the hook and its exact value shown on the CS5000 screen, press the ZERO and PRINT keys to enter in the weight. 13. The scale shows LL-03 LL-03. Apply the final weight and press the ZERO and PRINT keys. On the next screen enter the weight being applied. With the weight on the hook and its exact value shown on the CS5000 screen, press the ZERO and PRINT keys to enter in the weight. Finish The new calibration information is saved. 14. Press the calibration switch ONCE to disable calibration. This will prevent accidental entry into the calibration mode. If you are unsure of whether the switch is enabled or disabled, start going thorough the calibration menu again. After the AZT menu item, the scale should return to normal weighing instead of saving the AZT value and proceeding to EE-04. See the calibration switch section. 15. Replace the access plug which will cover the calibration switch. 16. Cover this plug with a new calibration seal (e.g. foil calibration sticker). 17. Verify the calibration. 18. Calibration complete. Legal-for-Trade Sealing For qualified calibration facilities: 1. After calibration push the calibration switch. The calibration switch is located on the upper right hand corner on the backside (side with battery caps) of the scale. 2. Verify that the scale returns to normal weighing when trying to access the weight calibration. 3. Replace the set screw that covers the cal switch. 4. Apply the protection sticker (sticker must adhere to Intercomp s specifications). 16

17 Error Messages [display reads ]: The CS5000 is waiting for a stable reading to continue. This also occurs when the unit is first turned on, or after ZERO or TARE is pressed. EE-00 OL-00 OE-00 OS HO-00 EEPROM error, the scale has had it's calibration corrupted or destroyed; the scale will require recalibration. Zero overload, the zero has moved outside it's limit. Return the scale's load to the initial zero-set and press ZERO, or turn the unit off and then back on. See 'Canadian specifications' (EE-04 in the 'calibration' section). The scale is over capacity. Reduce the load applied to the scale. OS Display error, the scale is unable to display the number completely. Head off, the scale head is turned off or the communication link between the scale head and base has otherwise failed. If both base and head are on and you get this message, try rotating or moving the base slightly. This can sometimes have a substantial effect on the signal received. The scale head is low in batteries. Turn the scale base off first, then replace the 8 'D' cell batteries in the head. BLB The batteries in the base controller require recharging or replacement LB-00 BLB EO: EO: This message occurs if the scale is turned on with a load applied which is greater than ±10% capacity. Return the scale s load to zero. This only occurs when Canadian specifications are turned on. See EE-04 in the Calibration section. E1 Error during calibration. It is caused by either the calibration strap being disabled, or a failure in the communication link. The scale will then exit calibration mode and return to normal weighing after a few seconds. See Calibration switch section. 17

18 Troubleshooting Caution: Changing some parts on the circuit board may cause a large change in calibration while others may or may not change the calibration, depending on the nature of the problem. The base unit contains the MPC board and the GPI Display board The head contains the A/D board. Problem: base only displays HO-00 HO-00, no communication Fix: Check the power on the head (LED labeled POWER). If the head does have sufficient power, this is probably a communication problem. Open the base unit and locate the transceiver. If the LED lights labeled RXD Data and TXD Data are not blinking, the transceivers are not communicating. Check to make sure the base and head unit have power. Also make sure they are within range and rotate units to try to get communication. Problem: no power, nothing on display Fix (applies to the base and the head): If nothing can be seen on the display, there is probably no power reaching the base circuitry. Possible causes at: bad or shorted battery pack, bad switch circuit, bad voltage regulator. Power might be reaching the unit, but the power supply might be shorted by a component or PCB trace in the power supply circuitry. Problem: random display (display usually reads ) Fix: On MPC board: check crystal (Y2). If the micro-controller is not receiving the correct or any oscillation, the microprocessor is not able to function properly. Other possibilities could be bad microprocessor (U1) on MPC board or display driver (U1 & U2 on GPI DISPLAY board) circuitry not functioning. Problem: low battery indication won t turn off Fix: The display will show a low battery condition ( LB-00 LB-00 for the head, or BLB BLB for the base controller). Check if battery power is too low. Look at the cells and charger circuit for these problems. If that is not the cause, the display driver( U1 & U2 on the GPI DISPLAY board) or low voltage circuitry could be bad. 18

19 Problem: rechargeable battery life has decreased Fix: The rechargeable batteries provided by Intercomp are high quality, high capacity Ni-Cad. However, all Ni-Cad batteries can exhibit some memory effects if they are repeatedly discharged to a certain point before recharging. If your observed battery life has decreased significantly from its initial performance, you may want to try this battery-conditioning sequence: Fully discharge the batteries by running the CS5000 until the display blinks LB LB (low battery) and keep the unit powered until the batteries are fully discharged. Following this, recharge the battery completely (typical charge time is 16 hours). This discharge/recharge cycle may need to be repeated. If this does not help, you may need to replace the Ni-Cad batteries. Problem: scale shuts off by itself Fix: Check the battery holder terminals. They may be bent and not making solid contact. If the scale turns off immediately after you take your finger off the button, there may be defective power circuitry or a bad keypad. Problem: scale locks up Fix: The microprocessor (U1) on the MPC board may need to be replaced. The microprocessor support circuitry could also be bad. Problem: weights jump or drift Fix: Try increasing the sample rate as described in the calibration section (pg. 13). Pertains to A/D board: If this does not help, the problem could be a bad load cell, defective amplifier (U5), bad A/D chip (U6), or contamination on the A/D circuit board. 19

20 Parts and Accessories Diagram: 500 lb capacity models See following page for parts list 20

21 Parts List: 500 lb capacity Item # QTY Part # Description control harness button cover screw keypad overlay logo overlay CS5000 display end window overlay pin MTA loadcell 10 1 insert display window unf screw loadcell threaded adapter loadcell retainer lower loadcell adapter loadcell housing retaining ring gasket top retaining ring retaining ring spacer screw set screw screw eye nut housing gasket eye nut battery tube screw battery spring battery plate battery cap screw battery tube end wing nut battery harness assembly assembly screw swivel hook assembly assembly nut nylon washer m/f standoff nut right board mount vibration mount display board nylon washer screw standoff A/D board left board mount unc screw lower retaining ring bellows hose clamp 21

22 Diagram: 2K lb capacity models Please see following page for parts table 22

23 Parts List: 2K lb capacity Item # QTY Part # Description control harness button cover screw keypad overlay logo overlay CS5000 display end window overlay pin MTA set screw loadcell (2K capacity CS5000) 11 1 insert display window loadcell threaded adapter loadcell retainer loadcell housing retaining ring gasket top retaining ring retaining ring spacer screw screw eye nut housing gasket eye nut battery tube screw battery spring battery plate battery cap screw battery tube end wing nut battery harness assembly assembly screw swivel hook assembly assembly nut nylon washer m/f standoff nut right board mount vibration mount display board nylon washer screw standoff A/D board left board mount unc screw lower retaining ring bellows hose clamp 23

24 Diagram: 5K lb, 10K lb capacities See the following page for parts list 24

25 Parts List: 5K lb, 10K lb capacity Item # QTY Part # Description control harness button cover screw keypad overlay logo overlay CS5000 display end window overlay pin MTA set screw loadcell (5K and 10K capacity CS5000) 11 1 insert display window loadcell threaded adapter loadcell housing retaining ring gasket top retaining ring screw screw eye nut housing gasket eye nut battery tube screw battery spring battery plate battery cap screw battery tube end wing nut battery harness assembly assembly screw swivel hook assembly assembly nut nylon washer m/f standoff nut right board mount vibration mount display board nylon washer screw standoff A/D board left board mount unc screw lower retaining ring bellows hose clamp 25

26 Diagram: 20K lb, 30K lb, capacities Please see following page for parts list 26

27 Parts List: 20K lb, 30K lb capacity Item # QTY Part # Description control harness button cover screw keypad overlay logo overlay CS5000 display end window overlay pin MTA set screw loadcell (20K capacity CS5000) loadcell (30K capacity CS5000) 11 1 insert display window locking nut top loadcell adapter bolt loadcell housing retaining ring gasket top retaining ring eye nut screw screw housing gasket end plate lower loadcell adapter battery tube screw battery spring battery plate battery cap screw battery tube end wing nut battery harness assembly assembly screw swivel hook assembly assembly nut nylon washer m/f standoff nut right board mount vibration mount display board nylon washer screw standoff A/D board left board mount unc screw lower retaining ring bellows hose clamp 27

28 Serial Output The CS5000 base has available two communications channels, the standard interface for both is RS-232. One is equipped with a CTS (clear to send) line and designed primarily for hookup to a printer. The second channel consists of signal wires only and is designed primarily for hookup to a score board or computer. Channel 1 outputs a ticket: cr/lf -XXXXXX.X lb G cr/lf -XXXXXX.X lb N cr/lf -XXXXXX.X lb T cr/lf -XXXXXX.X lb TOTAL cr/lf lf lf JAN DD, 19YY HH:MM:SSam cr/lf (the 19 could be 20, and the a could be p) lf lf Channel 2 outputs the net weight: -XXXXXX.X lb cr/lf There is a five switch dip pak located on the main circuit board inside the base unit, it's switches have the following meanings: Switch # On Off Function Channel 1 baud rate Channel 2 baud rate 3 on off Channel 1 continuous print 4 on off Channel 2 continuous print 5 on off RF interface (must be turned on, on CS5000) The Items in bold indicate the suggested defaults. NOTE: The RS-232 communication parameters: Fixed 8 data bits, no parity, 1 stop bit. Each channel will print under two conditions: 1: If the print key is pressed. 2: If the continuous print is turned on. 28

29 The signals for the two channels exist the box through the six pin connector on the bottom of the box. The wiring is listed on the following chart: Pin# A B C D E F Connection CH1 TXD CH1 CTS CH1 GND CH2 TXD CH2 GND NC Example Connections The connection of CH1 to a 9-pin PC communications port is: CS pin PC A (TXD) 2 (RXD) B (CTS) 7 (RTS) C (GND) 5 (GND) NOTE: For some setups it may be necessary to jump pins [6, 1, and 4] together on the PC port connector. The connection of CH1 to a 25-pin PC communications port is: CS pin PC A (TXD) 3 (RXD) B (CTS) 4 (RTS) C (GND) 7 (GND) NOTE: For some setups it may be necessary to jump pins [6, 8, and 20] together on the PC port connector. The connection of CH2 to an Intercomp S400 display is: CS5000 S400 D (TXD) 2 (RXD) E (GND) 7 (GND) The connection of CH2 to an Intercomp SA2000 display is: CS5000 SA2000 D (TXD) 3 (RXD) E (GND) 7 (GND) cont d on next page 29

30 The connection of CH2 to a 9-pin PC communication port is: CS5000 PC 9-pin D (TXD) 2 (RXD) E (GND) 5 (GND) Note: For some setups it may be necessary to jump pins [6, 1, and 4] together, and pins [7 and 8] together on the PC port connector. The connection of CH2 to a 25-pin PC communication port is: CS5000 PC 25-pin D (TXD) 3 (RXD) E (GND) 7 (GND) Note: For some setups it may be necessary to jump pins [6, 8, and 20] together, and pins [4 and 5] together on the PC port connector. 30

31 How to reach Intercomp Service Things to know: 1. The service is for a CS5000 crane scale. 2. When did you purchase your scale? 3. What is your serial number? 4. Whom did you purchase the scale through? For Intercomp Service call or fax: FAX # (763) (763) or fill out Service Support Form at: Copyright Intercomp Company 2008 All rights reserved 31

Digital Air Pressure Gauge Users Manual

Digital Air Pressure Gauge Users Manual Digital Air Pressure Gauge Users Manual Intercomp Co. 3839 County Road 116 Medina, MN 55340, U.S.A. (763)-476-2531 1-800-328-3336 Fax: 763-476-2613 www.intercompracing.com Manual #: 700099 Rev H Table

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

OCSM Series. High Resolution Digital Crane Scale. User Guide

OCSM Series. High Resolution Digital Crane Scale. User Guide OCSM Series High Resolution Digital Crane Scale Content 1. Safety Guide... 1 2. Features... 1 3. Specifications... 2 4. Capacity... 3 5. Display & Keys... 3 Scale & Remote Keys... 3 Indicators... 4 Message...

More information

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

Model 5511 Filler Controller User s Manual Version 1.1 October 2011 Thompson Scale Company WEIGHING SYSTEMS & PACKAGING MACHINERY CONTROLS 2758 Bingle Road Houston, Texas 77055 Phone: 713/932-9071 Fax: 713/932-9379 www.thompsonscale.com Model 5511 Filler Controller User

More information

SATEX SA 230. - Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND

SATEX SA 230. - Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND - Manual SATEX SA 230 PRECISION BALANCE Weegtechniek holland b.v. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND Tel. + 31 36 522 20 30 Fax. + 31 36 522 20 60 Email [email protected] Website www.satex.nl page

More information

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version

More information

OCS-S High Resolution Digital Crane Scale

OCS-S High Resolution Digital Crane Scale OCS-S High Resolution Digital Crane Scale Content 1. Safety Guide... 1 2. Features... 1 3. Specifications... 2 4. Capacity... 2 5. Dimension & Weight... 3 6. Display & Keys... 4 Scale Keys... 4 Indicators...

More information

CutMaster 82. 6.04 Major External Replacement Parts

CutMaster 82. 6.04 Major External Replacement Parts CutMaster 8 6.0 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-08 Tube, roll handle 9-0 Front Panel 9-07 Rear Panel 9-00 Art # A-080

More information

Ron 3025 Crane Scale with 1"/25mm Display

Ron 3025 Crane Scale with 1/25mm Display Exceptionally small dimensions enable minimum headroom loss. For example: Height of the 5t load cell is 16.7 inch / 423 mm Optional shock absorbing protective cage Optional IR remote control Short delivery

More information

BW-500 BED WEIGHER USER MANUAL

BW-500 BED WEIGHER USER MANUAL BW-500 BED WEIGHER USER MANUAL 0 1 TABLE OF CONTENTS SPECIFICATION... 3 Equipment... 4 INSTALLING WEIGH BEAM... 5 PREPARATION FOR MEASUREMENT... 6 DP3800 Indicator... 8 POWER SUPPLY... 8 PANEL... 9 KEY

More information

Forklift/Pallet Jack Scales Table of Contents

Forklift/Pallet Jack Scales Table of Contents Forklift/Pallet Jack Scales Table of Contents CLS-420 Wired Version...308 CLS-420 Wireless Version...311 CLS-920i Wired Version...314 CLS-920i Wireless Version...317 Intercomp PW800...320 Pallet Truck

More information

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510 User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP-2004-12 ver.1.0

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP-2004-12 ver.1.0 HIGH PRECISION BALANCE MWP OWNER S MANUAL MWP-2004-12 ver.1.0 INTRODUCTION------------------------------------------------1 1. INSTALLATION---------------------------------------------------2 Unpacking---------------------------------------------------------------2

More information

XP Series Balances Operation Manual

XP Series Balances Operation Manual XP Series Balances Operation Manual North and South America: 6542 Fig Street Arvada, Colorado 84 1-8-321-1135 Tel: 33-431-7255 Fax: 33-423-4831 U.K. and Ireland: Denver House, Sovereign Way Trafalgar Business

More information

Digital Weight Indicator Setup / Operation Manual

Digital Weight Indicator Setup / Operation Manual Digital Weight Indicator Setup / Operation Manual Revision 1.0 July 8, 2009 i TABLE OF CONTENTS Page INTRODUCTION... 1 FCC NOTE... 1 INSTALLATION... 1 PREPARATION... 1 CONNECTIONS... 2 CONNECTING THE WEIGH

More information

How To Use A Ci 2001A/B (I2) With A Power Supply (I3)

How To Use A Ci 2001A/B (I2) With A Power Supply (I3) Weighing Indicator CI-2001A/B OWNER S MANUAL CONTENTS PRECAUTIONS 4 INTRODUCTION 6 THE FEATURES OF CI-2001A/B 6 TECHNICAL SPECIFICATION 7 DIMENSIONS 8 FRONT PANEL(CI-2001A) 9 FRONT PANEL(CI-2001B) 11 REAR

More information

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User Manual. Humidity-Temperature Chart Recorder. Model RH520 User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,

More information

1. SAFETY INFORMATION

1. SAFETY INFORMATION RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter

More information

PPM Users Manual Signature Software 01-12-00

PPM Users Manual Signature Software 01-12-00 PPM Users Manual Signature Software 0-2-00 PPM User Manual /8/02 Software Versions: 0.0.27 Contents. Introduction 2 2. Parameters 3 2. Overload Limit...4 2.2 Relative Upper Limit...4 2.3 Relative Lower

More information

CASTON. Crane Scale. OWNER S MANUAL (BT Ver.) 9007-CT3-BT33-0 2006. 07

CASTON. Crane Scale. OWNER S MANUAL (BT Ver.) 9007-CT3-BT33-0 2006. 07 Crane Scale CASTON OWNER S MANUAL (BT Ver.) 9007-CT3-BT33-0 2006. 07 CONTENTS PRECAUTIONS 4 OVERALL VIEW 7 SPECIFICATIONS 7 DISPLAY & KEY FUNCTIONS 8 BATTERY USAGE 9 USE OF BATTERY CHARGER 9 FUNCTIONS

More information

TI-500E Plus DIGITAL WEIGHT INDICATOR Setup / Operation Manual

TI-500E Plus DIGITAL WEIGHT INDICATOR Setup / Operation Manual TI-500E Plus DIGITAL WEIGHT INDICATOR Setup / Operation Manual Revision 1.0 975 Deerfield Parkway Buffalo Grove, IL 60089 January 28, 2008 Tel (847) 419-9180 Fax (847) 419-1515 http://www.transcell.net

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

SECUREPAK DIGITAL TORQUE TESTER

SECUREPAK DIGITAL TORQUE TESTER SECUREPAK DIGITAL TORQUE TESTER Overview: The SecurePak Torque Tester is used to test and measure applied torque. The system firmware includes functions to automatically zero the unit when no torque is

More information

PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION

PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION Calibration Guide PREPARATION Adventurer Pro Adventurer Pro balances have two calibration methods: Span and Linearity. Some models have Internal Calibration (InCal ) for Span calibration. Ensure that the

More information

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G Auto-Levelling Rotary Laser Level RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G 77-496 / 77-429 / 77-439 / 77-497 / 77-427/ 77-441 Please read these instructions before operating the product Auto-Levelling

More information

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com [email protected] TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit

More information

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger

More information

DYNA-LINK TENSION LOAD SENSORS

DYNA-LINK TENSION LOAD SENSORS MSI7200 DYNA-LINK TENSION LOAD SENSORS User Guide Quality Industrial Weighing and Force Measurement Equipment RFL MSI7200With RF Remote Control MSI-7200 MSI-7200RFL Measurement Systems International RF

More information

Transmitter Interface Program

Transmitter Interface Program Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following

More information

CONTIENTS. 1. SPECIFICATIONS (mm)---------- 2 2. CAUTIONS--------------------- 3 3. INSTALLATION INSTRUCTION----- 3

CONTIENTS. 1. SPECIFICATIONS (mm)---------- 2 2. CAUTIONS--------------------- 3 3. INSTALLATION INSTRUCTION----- 3 CONTIENTS 2008.4 1. SPECIFICATIONS (mm)---------- 2 2. CAUTIONS--------------------- 3 3. INSTALLATION INSTRUCTION----- 3 4. PANEL LAYOUT----------------- 4 5. BUTTON FUNCTIONS------------- 5 6. OPERATING

More information

M O D U L E - 7 E Model CS-Caliprompter Operator s Manual

M O D U L E - 7 E Model CS-Caliprompter Operator s Manual O P E R A T I O N S A N D P R O C E D U R E S F O R C S - C A L I P R O M P T E R A N D A C C E S S O R I E S Model CS-Caliprompter Visual screen display allows easy step-by-step operation On-site programming

More information

Digital Indicator. Revision 1.4 September 24, 2004. 1999-2004 Transcell Technology, Inc. Contents subject to change without notice.

Digital Indicator. Revision 1.4 September 24, 2004. 1999-2004 Transcell Technology, Inc. Contents subject to change without notice. TI-1600 Series Digital Indicator Setup / Operation Manual Revision 1.4 September 24, 2004 1999-2004 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 975

More information

Model 349KLX Remote Display Digital Scale User Instructions

Model 349KLX Remote Display Digital Scale User Instructions Model 349KLX Remote Display Digital Scale User Instructions P/N UM349KLX Rev 3-080713 1 Model 349KLX Thank you for your purchase of this Health o meter Professional product. Please read this manual carefully,

More information

CutMaster 102. 6.04 Major External Replacement Parts

CutMaster 102. 6.04 Major External Replacement Parts CutMaster 0 6.04 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-086 Tube, roll handle 9-0 4 Front Panel 9-087 Rear Panel 9-00 4 Art #

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

4-Channel Thermometer / Datalogger

4-Channel Thermometer / Datalogger USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter

More information

POCKET READER AND POCKET READER EX MANUAL

POCKET READER AND POCKET READER EX MANUAL POCKET READER AND POCKET READER EX MANUAL NICAD CONVERSION USE ONLY WITH 60mA CP TRICKLE CHARGER SUPPLIED CONTENTS 1. Batteries Installation...3 For best results Recommended Batteries...4 Automatic Shut

More information

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL e-4 SAFETY PRECAUTIONS Federal

More information

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No. BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER Installation, Operation, and Maintenance Instructions Manual No. M06-512 SPECIALISTS IN THE MEASUREMENT AND CONTROL OF VISCOSITY BROOKFIELD

More information

Bluetooth to Serial Adapter

Bluetooth to Serial Adapter Bluetooth to Serial Adapter Third Edition, Oct 2007 Version 3.0 771-BTS1009C3-001 Contents 1.0 Features....P.2 2.0 Package Content....P.2 3.0 Hard Drives Requirement.P.2 4.0 Specifications.P.3 5.0 Pin

More information

RC2200DK Demonstration Kit User Manual

RC2200DK Demonstration Kit User Manual Demonstration Kit User Manual Table of contents TABLE OF CONTENTS... 1 QUICK INTRODUCTION... 2 INTRODUCTION... 3 DEMONSTRATION BOARD... 4 POWER SUPPLY SECTION... 5 RS-232 INTERFACE... 6 CONNECTORS... 7

More information

MANUAL FOR RX700 LR and NR

MANUAL FOR RX700 LR and NR MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical

More information

WIRELESS STATUS MONITOR

WIRELESS STATUS MONITOR INSTALLATION INSTRUCTIONS WIRELESS STATUS MONITOR (WSM or AUWSM) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-032-D Schlage 245 W. Roosevelt Road,

More information

My Weigh Ultraship Series User Manual

My Weigh Ultraship Series User Manual My Weigh Ultraship Series User Manual Low Batteries, bad battery connections & Faulty AC Adaptors are the #1 cause of Ultraship malfunction and inaccuracy! We test all of our scale returns from consumers.

More information

User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510

User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510 User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

SMS Alarm. User Manual

SMS Alarm. User Manual SMS Alarm User Manual 1 1. Introduction... 2 2. SMSA1000 Specifications... 3 3. Parts Identifications... 4 4. Packing Contents... 5 5. Battery and SIM Card Installation... 6 5.1 Open the Back Cover...

More information

Model SR463iR-H, SR463iR-3H Series In-Floor Platform Scale Operating and Service Manual Part No. MAN463iR-H_151216 Page 1 of 18

Model SR463iR-H, SR463iR-3H Series In-Floor Platform Scale Operating and Service Manual Part No. MAN463iR-H_151216 Page 1 of 18 SR463iR-H SERIES Model SR463iR-H, SR463iR-3H Series In-Floor Platform Scale Part No. MAN463iR-H_151216 Page 1 of 18 S by S Instruments, Inc. In-Floor Platform Scale Operating and Service Manual Part No.

More information

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching) INSTRUCTION MANUAL ➏ ➋ ➊ Product Features ➎ ➍ ➌ Built-in wireless Bluetooth 3.0 keyboard Compatible across ios, Android, and Windows, enabling you to mix and match with devices Ultra-thin, lightweight

More information

High precision counting scale. Operation Manual. l RCZ-A Series

High precision counting scale. Operation Manual. l RCZ-A Series High precision counting scale Operation Manual l RCZ-A Series TABLE OF CONTENTS I. PRECAUTIONS BEFORE USING THE SCALE 1 II. EXPLANATION OF DISPLAY SYMBOLS 2 III. KEYPAD FUNCTIONS 4 IV. OPERATIONS 5 SWITCH

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER

123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER 123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual

More information

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power) MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

User Guide. Temperature and Humidity Datalogger. Model 42280

User Guide. Temperature and Humidity Datalogger. Model 42280 User Guide Temperature and Humidity Datalogger Model 42280 Introduction Congratulations on your purchase of the Extech 42280 Thermometer and Relative Humidity Datalogger. The 42280 is a wall-mount, tripod

More information

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information Safety Safety Is Your Responsibility DANGER To avoid personal injury or death, carefully read and understand all instructions pertaining to the Anthony Liftgates product. Do not attempt to install, operate,

More information

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration

More information

Adam Equipment. CPWplus. RANGE OF SCALES (P.N. 9009, Rev. C, June 2008)

Adam Equipment. CPWplus. RANGE OF SCALES (P.N. 9009, Rev. C, June 2008) Adam Equipment CPWplus RANGE OF SCALES (P.N. 9009, Rev. C, June 2008) Adam Equipment Company 2008 Adam Equipment Company 2008 CONTENTS 1.0 INTRODUCTION...3 2.0 SPECIFICATIONS...4 3.0 INSTALLATION...5 3.1

More information

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to

More information

Adaptability to Enhanced Security

Adaptability to Enhanced Security Installer Guide Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I/O function, enhancing door access

More information

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R) Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R) This document outlines the specifications for the Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

More information

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT P.O. BOX 11846 TUCSON, AZ 85734 (520) 294-3292 FAX (520) 741-2837 www.iotaengineering.com INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always

More information

Adaptability to Enhanced Security

Adaptability to Enhanced Security Installer Guide Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I/O function, enhancing door access

More information

4.3-inch Back-Up Camera

4.3-inch Back-Up Camera TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION

More information

ASSEMBLY MANUAL SE-4S35

ASSEMBLY MANUAL SE-4S35 Automatic drive ASSEBLY ANUAL SE-4S35 AI-4S35 SG-4R35 Battery box otor unit Inter-4 hub CONTENTS WARNING 1 INSTALLATION CONITIONS Battery box Speed sensor Cable lengths and diameters otor unit Recommended

More information

Back-UPS Pro 1300/1500 Installation and Operation

Back-UPS Pro 1300/1500 Installation and Operation Back-UPS Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a

More information

=============================== WARNING

=============================== WARNING =============================== WARNING EXPLANATION OF GRAPHICAL SYMBOLS This symbol is intended to alert the user to the presence of unprotected dangerous voltage" within the product's enclosure that

More information

Range Road RR Series Semi-Automatic Firewood Processor. Crated Unit Assembly Manual

Range Road RR Series Semi-Automatic Firewood Processor. Crated Unit Assembly Manual Range Road RR Series Semi-Automatic Firewood Processor Crated Unit Assembly Manual 1 1) Undo 8-18mm x 19mm Nuts and bolts, 2 on each leg of top frame 2) Lift top of Metal crate off and move out of work

More information

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual GPS AutoSteer System Installation Manual Supported Vehicles John Deere Sprayers 4720 4630 4730 4830 AutoTrac Ready PN: 602-0227-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual

More information

Keep it Simple Timing

Keep it Simple Timing Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring

More information

ExStik TM ph Waterproof Meters

ExStik TM ph Waterproof Meters User Guide ExStik TM ph Waterproof Meters Models PH100 & PH110 Patent Pending ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE / HOLD button 4. CAL / RECALL

More information

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier Refer to the Lifestyle SA-2 & SA-3 Amplifier service manuals, part number 271720 for schematics, PCB layouts and parts lists. Preventative Repair Measures

More information

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011 WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers Installation Guide February, 2011 Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 [email protected] 1 Disclaimer The following warranty

More information

430 Power/Electronics Replacement

430 Power/Electronics Replacement Replacing the main board WARNING Before proceeding, turn off the main power switch and unplug the power cord. Caution Make sure you are properly grounded with an ESD strap before continuing. The main printed

More information

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge! Parts Manual TWIN 2 & 3 Parts & Accessories F210846R01 Your efficiency is our Challenge! All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm

More information

Six-servo Robot Arm. DAGU Hi-Tech Electronic Co., LTD www.arexx.com.cn. Six-servo Robot Arm

Six-servo Robot Arm. DAGU Hi-Tech Electronic Co., LTD www.arexx.com.cn. Six-servo Robot Arm Six-servo Robot Arm 1 1, Introduction 1.1, Function Briefing Servo robot, as the name suggests, is the six servo motor-driven robot arm. Since the arm has a few joints, we can imagine, our human arm, in

More information

LDG DTS-4/4R Desktop Coaxial Switch / Remote

LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com

More information

To Purchase This Item, Visit BMI Gaming www.bmigaming.com 1-800-746-2255 + 1-561-391-7200. Operation Manual

To Purchase This Item, Visit BMI Gaming www.bmigaming.com 1-800-746-2255 + 1-561-391-7200. Operation Manual Operation Manual 90MAN 01 B Copyright 2008 Patent Pending All Rights Reserved Table of Contents Game Play 3 Game Set up 4 Technical Description 5 Programming 6 10 Error Codes 9 Electronic Components 11

More information

WPR400 Wireless Portable Reader

WPR400 Wireless Portable Reader P516-098 WPR400 Wireless Portable Reader User guide Para el idioma español, navegue hacia www.schlage.com/support. Pour la portion française, veuillez consulter le site www.schlage.com/support. Contents

More information

Time Recorder. User Manual. PDF created with FinePrint pdffactory trial version www.pdffactory.com

Time Recorder. User Manual. PDF created with FinePrint pdffactory trial version www.pdffactory.com Time Recorder User Manual 1 (1) Specifications: 1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase. 2. Power consumption Normal 2W (MAX 30W) 3. Standard time signal Quartz

More information

Ground Resistance Clamp On Tester

Ground Resistance Clamp On Tester USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground

More information

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3. ZAPPY 3 OWNER S MANUAL Read this manual completely before riding your Electric ZAPPY 3. TECHNICAL INFORMATION Model No. : ZAPPY 3 Product size Type of motor Motor power Battery type Battery Charger Charging

More information

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION SP1790JK 900MHz Wireless Indoor/Outdoor Speakers INTRODUCTION This 900 MHz digital hybrid wireless speaker system uses the latest wireless technology that enables you to enjoy music and TV sound anywhere

More information

MAINTENANCE & TROUBLESHOOTING

MAINTENANCE & TROUBLESHOOTING MAINTENANCE & TROUBLESHOOTING This section describes how to: clean the lens replace the projection lamp replace the batteries in the remote use the security lock feature troubleshoot the projector Cleaning

More information

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec www.startwithunitec.com

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec www.startwithunitec.com ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start Unitec www.startwithunitec.com Proprietary Information and Materials of Unitec, Inc. Such proprietary information and materials

More information

E E V R E - R S - O S L O A L R

E E V R E - R S - O S L O A L R Solar Eye User Manual Edition JIANGSU EVER-SOLAR NEW ENERGY CO., LTD. Revision History Date Edition Specification 17/08/2011 1.0 Create File 02/09/2011 1.1 Add Micro SD function description www.ever-solar.com

More information

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types Installation Guide LR-HWLV-HVAC TouchPRO Wireless Touchscreen Thermostat System Types Gas, oil, or electric heat with air conditioning Warm air, hot water, high efficiency furnaces, heat pumps, steam,

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

HP ProDisplay P19A LED Backlit Monitor. User Guide

HP ProDisplay P19A LED Backlit Monitor. User Guide HP ProDisplay P19A LED Backlit Monitor User Guide 2013 Hewlett-Packard Development Company, L.P. The only warranties for HP products and services are set forth in the express warranty statements accompanying

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.

More information

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev B 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)

More information

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales Installation information METTLER TOLEDO MultiRange Floor scales / Pit scales KC300/KCS300 KC600/KCS600 KD600/KD1500 KE1500/KE3000 KES1500/KES3000 KG3000/KG6000 KN1500 Floor scales / Pit scales Contents

More information

RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer

RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer EN FR IT DE ES CONTENTS / EN Title CONTENTS Page 1. SAFETY INFORMATION...1 2. INTRODUCTION...2 3. SPECIFICATIONS...3 4. PARTS & CONTROLS...4

More information

GSM Desktop phone DPH101. User manual v1.00

GSM Desktop phone DPH101. User manual v1.00 GSM Desktop phone DPH101 User manual v1.00 LEGAL NOTICE Copyright 2011 TELTONIKA Ltd. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this document

More information

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions EXPLORE 4-Leg Teaming Table with Screen Share Monitor Display Requirements: your flat panel display must confirm to the following requirements. y With the stand removed, the monitor must not exceed 40

More information

T Sentry 4 Multi-Point Digital Alarm Instruction Manual

T Sentry 4 Multi-Point Digital Alarm Instruction Manual T Sentry 4 Multi-Point Digital Alarm Instruction Manual Introduction The T Sentry4 (TS4) is a microprocessor-based temperature monitoring and alarm device with user programmable high-low alarm setpoints

More information

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI American Weigh Scales, Inc. CQ-Series Digital Pocket Scale 7 4 1 0. 8 9 5 6 2 3 x = - CALI + CALC MODE M CAL AC CE % TARE OFF ON MC MR CQ-350 (350x0.1g) CQ-500 (500x0.1g) User Manual CQ-Series Manual Thank

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

User Manual for CH-PFC76810

User Manual for CH-PFC76810 AA Portable Power Corp www.batteryspace.com, Email: [email protected] User Manual for CH-PFC76810 1. Overview The CH-PFC76810 charger is suitable for charging lithium ion battery packs such as those

More information

TS510 & TS500. Installation & User Guide. Compatible Equipment

TS510 & TS500. Installation & User Guide. Compatible Equipment Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction

More information