1 Low voltage transformers
2 Open core CT SMART OBJECTS
3 Time sensors Detect the signals, where they rise Low voltage transformers In the practice of industrial electrical measurement, some devices of the measurement chain adapt the signal to make it compatible with the measuring instruments. In the complex of these devices, the transformer is one of the most important examples for diffusion and universality of use. From the simplest applications in which analog and digital indicators are used, to the more complex which is expected the use of transducers, KWh meters, multifunctions or protection devices, the supply of current and voltage inputs is generally performed by means of transformers. The use of transformers, besides conditioning the signal, allows to obtain a complete galvanic isolation between the primary and secondary circuit, granting the necessary level of insulation between apparatus user and protection or measuring instruments. Current Transformers They adapt the current values to the measuring and protection equipments, delivering a reduced a secondary current proportional to the standard values 5A or 1A. IME current transformers comply with EN Standards and depending on the intended use they can be divided into: Measuring Classes: 0,5-1-3 / Applications: counting and industrial measurements Accuracy Classes: 0,2-0,2s-0,5s / Applications: counting and measuring with an high degree of reliability at the lowest currents (1% in classes with 0,2 or 0,5s) Protection Classes: 5P5-5P-5P-5P / Applications: combination with protection relays Summation Classes: 0,5-1 / applications counting and industrial measurements on different lines belonging to the same voltage system. Voltage Transformers They adjust the values of the primary voltage to the measuring or protection devices delivering a reduced secondary voltage to the standard values V (other values upon request). IME voltage transformers comply with EN Standards and depending on the intended use can be divided into: Measuring Classes: 0,5-1 / Applications: counting and industrial measurements Accuracy Class: 0,2 / Applications: counting and measuring with an high degree of reliability Protection Class: 3P / Applications: combination with protection relays 3
4 Current Transformers CT Cable/passing bar (Primary currents...000a) CT Wound primary (Primary currents A) With more cable passages (windings) inside the transformer it is possible to reduce the primary current value, keeping unchanged the secondary current values, performances, class (actual primary current = rated primary current, number of windings; i.e. 1/5A with 2 passing cable = /5A with 3 passing cable = /5A) CT fixing Depending on the model the current transformers can be mounted as follows: 1 1 Direct fixing on primary bars by means of screws with insulating caps 2 Fixing screw for wall mounting with pins 3 Fixing on DIN rail CT connections The terminals of current transformers are marked with double wordings: Primary circuit P1(K) - P2(L) Secondary circuit s1(k) - s2(l) 1 Some models are also provided with arrows to show the correct direction of the CT connection on the cable / bar in order to avoid the errors of reverse current. 2 The secondary terminals, depending on the models, can be tightened with a nut, screw, double faston + screw; these last ones are useful to short-circuit the CT secondary before disconnecting the equipment to avoid dangerous voltages generated by the opening of the circuit (no-load operation). Ipn s1 k P1 K Isn s2 l P2 L LOAD 1 3 However, to overcome this situation, for all the current transformers, IME proposes a static accessory (ATAP0), allowing the instantaneous reclosing of the secondary circuit of open CT due to circuit interruption or equipment removal as well as instantaneous automatic recovery on the return to normal conditions. Protection degree IP secondary terminals (for models TAS... TAU... TAQ... BSA... only with the use of sealable terminal covers). 4
5 Open core CT (Primary currents 00A) Voltage Transformers VT connections The VT terminals are marked with different wordings depending on the type of connection: Primary circuit phase-phase A-B Secondary circuit phase-phase a-b Primary circuit phase-neutral A-N Secondary circuit phase-neutral a-n Designed for mounting in existing plants, they can be placed without breaking down the primary circuit or modifying the plant Screw and faston primary and secondary terminals and screw only for the model BTV3 Protection degree for terminals IP (for models BTV//// only with the use of the sealable terminal covers) Connection Phase-Phase a b Connection Phase-Neutral a n A B A N U N U : VT fixing The voltage transformers can be flush / wall mounted with fixing screw 2 3 5
6 Current Transformers - Measuring Cable/passing bar (a) (b) Model TAIBB TA221 TA327 TA42 TA432 TA5 TAC0 TAC1 TAS4 TAS1 TAS5 TAS4 TAS2 TAS2B TAS127 TAS127B TAU TAU TAU11 TAU12 TAU13 Code TABB TA221 TA327 TA42 TA432 TA5 TA0 TA11 TASI TASN (a) TASL (a) TASO (a) TAMP (a) TAMQ (a) TASR (a) TASS TAUB TAUC TAUD TAUE TAUF (b) TASL 3 (b) TASO 3 (b) TAMP 3 (b) TAMQ 3 (b) TASR 3 (b) TASS 3 Technical note NT51 NT11 NT12 NT13 NT14 NT NT712 NT713 NT5 NT573 NT51 NT574 NT7 NT77 NT522 NT523 NT5 NT717 NT71 NT1 NT Type passing passing passing passing passing passing passing passing passing passing passing passing passing passing passing passing passing passing passing passing passing primary primary primary primary primary primary primary primary primary primary primary primary primary primary primary primary primary primary primary primary primary Width (mm) 44 4, (a) 4 (b) (a) 11 (b) (a) 12 (b) 135 (a) 12 (b) (a) (b) 125 (a) (b) Height (mm) (a) 0 (b) 11 (a) (b) 12 (a) (b) 12 (a) 135 (b) (a) (b) (a) 125 (b) 273,5 233,5 273,5 333,5 333,5 Cable (mm) Ø21 Ø21 Ø27 Ø2 Ø32 Ø Ø0 Ø1 25,5x25,5 Window (mm) 25,5x,5 32,5x,5,5x,5 51x31 4x31 32x5 (a) 34x4 (a) 3x2 (a) 54x2 (a) 3x127 (a) 54x127 (a) 1x12,5,5x,5 32,5x,5 32,5x,5,5x12,5,5x12,5 4x11 1x11 5x32 (b) 4x34 (b) 2x3 (b) 2x54 (b) 127x3 (b) 127x54 (b),5x,5 55x 1x125 1x 55x225 1x225 Primary current cl.0,5 cl.3 cl.0,5 cl.3 cl.0,5 cl.3 cl.0,5 cl.0,5 cl.3 cl.0,5 cl.0,5 cl.0,5 cl.0,5 cl.0,5 cl.0,5 cl.0,5 cl.0,5 cl.0,5 cl.0,5 cl.0,5 cl.0,5 cl.0,5 cl.0,5 cl.0,5 cl.0,5 A 1 A 1,25 1,5 2,5 1,5 0A 1,25 2 1,5 3 2,5 70A 1,5 2,5 1,5 4 1,5 3 A 1,5 2, ,5 3 0A 1,5 2, ,5 3,5 A 2 2,5 3, A 2,5 3, , A 2,5 3, ,5 2 1A , A ,5 3 1,5 3 0A 4 5, , ,5 3 2A , A 7, , ,5 2 0A A A A A A A A A A A A A A A A 25 00A A A code see page
7 Current Transformers - Measuring Wound primary Open core Summation Model TAQ1 TAQ2 TAQ TAQ TAQ Code TAQE TAQA TAQB TAQC TAQD Technical note NT725 NT72 NT727 NT72 NT72 Type wound primary wound primary wound primary wound primary wound primary Width (mm) Height (mm) ,5 1 Primary current cl.0,5 cl.0,5 cl.0,5 cl.0,5 5A A A A A A A A A A 2 4 A 2 4 0A 2 4 A 1A 125A 1A A 0A 2A 0A 0A 0A 00A code see page Model TRA11 TRA TRA50 TRA12 TRA1R Code TAAA TAAB TA50 TA12 TAAF Technical note NT721 NT722 NT41 NT42 NT1 Type open core open core open core open core open core Width (mm) Height (mm) Cable (mm) Ø1 Ø1 Window (mm),5x0,5 0,5x1,5 0x Primary current cl.0,5 cl.3 cl.0,5 cl.3 cl.0,5 cl.0,5 cl.3 cl.0,5 cl.3 A 3 3 1A 3 3 1A 5 5 0A 5 5 2A A 5 5 1,5 3 0A 5 5 1,5 3 0A 2, A 2, A A 5 5 A 11 A 00A A A A 25 00A 25 code see page Model BSA02 BSA03 BTA2 Code TAEA TAEA TAEB Technical note NT731 NT731 NT732 Type summation summation summation Width (mm) Height (mm) Primary current cl.0,5 cl.0,5 cl.0,5 5+5A 5+5+5A A A A 1+1A 1+1+1A A A A code see page
8 Current Transformers - Accuracy Cable/passing bar Wound primary (a) (b) Model TA327 TA432 TAS5 TAS4 TAS2 TAS127 TAS127B Code TA327 S TA432 S (a) TASL S (a) TASO S (a) TAMP S (a) TASR S (a) TASS S (b) TASL 3S (b) TASO 3S (b) TAMP 3S (b) TASR 3S (b) TASS 3S Technical note NT2 NT NT31 NT32 NT33 NT34 NT35 Type passing primary passing primary passing primary passing primary passing primary passing primary passing primary Width (mm) (a) 4 (b) (a) 11 (b) (a) 12 (b) (a) (b) 125 (a) (b) Height (mm) (a) 0 (b) 11 (a) (b) 12 (a) (b) (a) (b) (a) 125 (b) Cable (mm) Ø27 Ø32 Window (mm) P 25,5x,5 32,5x,5 25,5x25,5 32,5x,5,5x,5 32x5 (a) 34x4 (a) 3x2 (a) 3x127 (a) 54x127 (a) 5x32 (b) 4x34 (b) 2x3 (b) 127x3 (b) 127x54 (b) Primary current cl.0,2s cl.0,2 cl.0,5s cl.0,2s cl.0,2 cl.0,5s cl.0,2s cl.0,2 cl.0,5s cl.0,2s cl.0,2 cl.0,5s cl.0,2s cl.0,2 cl.0,5s cl.0,2s cl.0,2 cl.0,5s cl.0,2s cl.0,2 cl.0,5s 1A 1 1,5 2 A 1 1,5 2 0A 2 2, ,5 2,5 2A 2 2, ,5 2,5 0A 2, , A 4 5 1, A 7 2, A A A A A ,5 4 A ,5 5 7,5 12A ,5 5 7,5 A ,5 7,5 7,5 12,5 7,5 12,5 0A ,5 7,5 7,5 12,5 7,5 12,5 00A ,5 20A ,5 00A A 25 00A 25 code see page Model TAQ2 TAQ TAQ Code TAQA S TAQB S TAQC S Technical note NT24 NT25 NT2 Type wound wound wound primary primary primary Width (mm) Height (mm) 2 2 2,5 Primary current cl.0,2 cl.0,5s cl.0,2s cl.0,2 cl.0,5s cl.0,2 cl.0,5s 5A A A A A A A A A A 5 A 5 0A 5 A 5 1A 5 125A 5 1A 5 code see page
9 Current Transformers - Protection Cable/passing bar Wound primary (a) (b) Model TAS3P TAS0 TAS0P TAS2BP TAS125 TAS125P TAU1P TAU1P TAU1P TAU111P TAU121P TAU131P Code TAWA TASM TAWB (a) TAPQ TASQ TAWC TAXA TAXB TAXC TAXD TAXE TAXF (b) TAPQ 3 Technical note NT45 NT571 NT572 NT7 NT5 NT57 NT7 NT71 NT71 NT7 NT21 NT22 Type passing passing passing passing passing passing passing passing passing passing passing passing primary primary primary primary primary primary primary primary primary primary primary primary Width (mm) (a) 12 (b) Height (mm) 117, (a) 135 (b) ,5 273,5 233,5 273,5 333,5 333,5 Window (mm) 41x21 51x 2x32 2x32 4x1 54x2 (a) 2x54 (b) 127X54 127x54 55x125 55x 1x125 1x 55x225 1x225 Model TAQP TAQP Code TAVB TA Technical note NT23 NT7 Type wound wound primary primary Width (mm) 5 1 Height (mm) 2,5 1 Primary current cl.5p5 cl.5p cl.5p5 cl.5p cl.5p5 cl.5p cl.5p cl.5p cl.5p5 cl.5p cl.5p5 cl.5p cl.5p5 cl.5p cl.5p cl.5p cl.5p5 cl.5p cl.5p cl.5p cl.5p5 cl.5p cl.5p cl.5p cl.5p5 cl.5p cl.5p cl.5p cl.5p5 cl.5p cl.5p cl.5p cl.5p5 cl.5p cl.5p cl.5p cl.5p5 cl.5p cl.5p cl.5p 2A 2,5 1 0A 3,5 1,2 2,5 4 2,5 1,5 0A 4 1,5 7 2, ,5 2,5 0A 5 1, , A , A , A A 7 1,5 4 4,5 2, A 7 1, A 1, A A 1, ,5 2 1,5 2 0A 1, A ,5 3 1,5 3 20A , , A ,5 25 7,5 00A A A ,5 0 12,5 000A code see page Primary current cl.5p5 cl.5p cl.5p5 cl.5p 5A A A A A A A A A A A A A A A A A A A 4 0A 4 00A 4 code see page
10 1.17 Compacta Series SMART PRODUCTS
11 Voltage Transformers - Measuring / Protection Voltage Transformers - Accuracy Compacta Series SMART PRODUCTS Model BTV3 BTV BTV BTV BTV BTV Model BTV BTV BTV BTV BTV Code TV TVVB TVVC TVVD TVVE TVVF Code TVVB S TVVC S TVVD S TVVE S TVVF S Technical note NT733 NT734 NT735 NT73 NT737 NT73 Technical note NT3 NT37 NT3 NT3 NT Width (mm) Height (mm) Width (mm) Height (mm) Depth (mm) Depth (mm) Primary voltage cl.0,5 cl.3p Primary voltage cl.0,2 cl.0,2 cl.0,2 cl.0,2 cl.0,2 V 1 0 2V 2,5 4 1V 1 0 2V 2,5 4 1V 1 0 0V 2,5 4 2V 1 0 4V 2,5 4 2V 1 0 4V 2,5 4 0V 1 0 0V 2,5 4 4V V 2,5 4 4V 1 0 0V 0V 1 0 0V 00V V 0V V 0V 1 0 0V 700V V 1 0 0V 1 0 For primary voltage : 3 code see page cl.3p cl.0,5 cl.3p cl.0,5 cl.3p cl.0,5 cl.3p cl.0,5 cl.0,5 cl.3p cl.0,5 cl.3p cl.0,5 cl.3p cl.0,5 cl.3p cl.0,5 cl.3p For primary voltage : 3 code see page cl.0,2 cl.0,2 cl.0,2 cl.0,2 cl.0,
12 Current Transformers Measuring Cable/passing bar TAIBB NT51 T A B B 5 0 B /5A T A B B 5 0 B /5A T A B B 5 0 B 0 0 0/5A T A B B 5 0 B /5A T A B B 5 0 B /5A T A B B 5 0 B 0 0 0/5A T A B B 5 0 C /5A T A B B 5 0 C /5A T A B B 5 0 C /5A T A B B 5 0 C /5A T A B B 5 0 C 1 0 /5A T A B B 5 0 C /5A T A B B 5 0 C /5A T A B B 5 0 C /5A TA42 NT13 T A C /5A T A C 1 0 /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A TAC0 NT712 T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A D /5A T A B B * TA221 NT11 T A B /5A T A B 0 0 0/5A T A B /5A T A B /5A T A B 0 0 0/5A T A C /5A T A C /5A T A C /5A T A C /5A T A C 1 0 /5A T A C /5A T A C /5A T A C /5A T A TA432 NT14 T A C /5A T A C /5A T A C /5A T A C /5A T A C 1 0 /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A D /5A TAC1 NT713 T A C /5A T A C /5A T A C /5A T A C /5A T A D /5A T A D /5A T A D /5A T A TA327 NT12 T A B /5A T A B 0 0 0/5A T A B /5A T A B /5A T A B 0 0 0/5A T A C /5A T A C /5A T A C /5A T A C /5A T A C 1 0 /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A TA5 NT T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A D /5A T A D /5A T A T A * Primary current up to 0A Accessories sealable terminal cover for TAIBB A T A C O P 1 2 sealable terminal cover for TA221/TA327/TA42/TA432/TA5 A T A C O P 1 3 protection CT secondary winding opening A T A P 0 1 5
13 Current Transformers Measuring Cable/passing bar TAS4 NT5 T A S I 5 0 C /5A T A S I 5 0 C /5A T A S I 5 0 C /5A T A S I 5 0 C /5A T A S I 5 0 C /5A T A S I 5 0 C /5A T A S I 5 0 C /5A T A S I 5 0 C /5A T A S I 5 0 D /5A T A S I 5 0 D /5A T A S I 5 0 D /5A T A S I 5 0 D /5A T A S I 5 0 D 1 0 0/5A T A S I TAS1 NT573 T A S N 5 0 C /5A T A S N 5 0 C /5A T A S N 5 0 C /5A T A S N 5 0 C /5A T A S N 5 0 C /5A T A S N 5 0 C /5A T A S N 5 0 D /5A T A S N 5 0 D /5A T A S N 5 0 D /5A T A S N 5 0 D /5A T A S N 5 0 D 1 0 0/5A T A S N 5 0 D /5A T A S N 5 0 D /5A T A S N TAS5 NT51 T A S L 5 0 C /5A T A S L 5 0 C /5A T A S L 5 0 C /5A T A S L 5 0 C /5A T A S L 5 0 C /5A T A S L 5 0 C /5A T A S L 5 0 C /5A T A S L 5 0 C /5A T A S L 5 0 D /5A T A S L 5 0 D /5A T A S L 5 0 D /5A T A S L 5 0 D /5A T A S L 5 0 D 1 0 0/5A T A S L 5 0 D /5A TAS4 NT574 T A S O 5 0 C /5A T A S O 5 0 C /5A T A S O 5 0 C /5A T A S O 5 0 C /5A T A S O 5 0 C /5A T A S O 5 0 C /5A T A S O 5 0 C /5A T A S O 5 0 D /5A T A S O 5 0 D /5A T A S O 5 0 D /5A T A S O 5 0 D /5A T A S O 5 0 D 1 0 0/5A T A S O 5 0 D /5A T A S O 5 0 D /5A T A S O T A S O TAS2 NT7 T A M P 5 0 C /5A T A M P 5 0 D /5A T A M P 5 0 D /5A T A M P 5 0 D /5A T A M P 5 0 D /5A T A M P 5 0 D 1 0 0/5A T A M P 5 0 D /5A T A M P 5 0 D /5A T A M P 5 0 D /5A T A M P T A M P TAS2B NT77 T A M Q 5 0 C /5A T A M Q 5 0 D /5A T A M Q 5 0 D /5A T A M Q 5 0 D /5A T A M Q 5 0 D /5A T A M Q 5 0 D 1 0 0/5A T A M Q 5 0 D /5A T A M Q 5 0 D /5A T A M Q 5 0 D /5A T A M Q 5 0 D /5A T A M Q 5 0 D /5A T A M Q T A M Q TAS127 NT522 T A S R 5 0 C /5A T A S R 5 0 C /5A T A S R 5 0 C /5A T A S R 5 0 C /5A T A S R 5 0 C /5A T A S R 5 0 C /5A T A S R 5 0 D /5A T A S R 5 0 D /5A T A S R 5 0 D /5A T A S R 5 0 D /5A T A S R 5 0 D 1 0 0/5A T A S R 5 0 D /5A T A S R 5 0 D /5A T A S R 5 0 D /5A T A S R 5 0 D /5A T A S R 5 0 D /5A T A S R T A S R TAS127B NT523 T A S S 5 0 C /5A T A S S 5 0 C /5A T A S S 5 0 C /5A T A S S 5 0 C /5A T A S S 5 0 C /5A T A S S 5 0 C /5A T A S S 5 0 D /5A T A S S 5 0 D /5A T A S S 5 0 D /5A T A S S 5 0 D /5A T A S S 5 0 D 1 0 0/5A T A S S 5 0 D /5A T A S S 5 0 D /5A T A S S 5 0 D /5A T A S S 5 0 D /5A T A S S 5 0 D /5A T A S S T A S S T A S L T A S L Accessories sealable terminal cover for TAS4/TAS1 A T A C O P 0 3 sealable terminal cover for TAS5/TAS4/TAS2/TAS2B/TAS127/TAS127B A T A C O P 0 4 protection CT secondary winding opening A T A P
14 Current Transformers Measuring Cable/passing bar TAU NT5 T A U B 5 0 D /5A T A U B 5 0 D /5A T A U B 5 0 D /5A T A U B 5 0 D /5A T A U B 5 0 D /5A T A U B 5 0 D /5A T A U B TAU NT717 T A U C 5 0 D /5A T A U C 5 0 D /5A T A U C 5 0 D /5A T A U C 5 0 D /5A T A U C 5 0 D /5A T A U C 5 0 D /5A T A U C 5 0 D /5A Current Transformers Measuring Wound primary TAQ1 NT725 T A Q E 5 0 A /5A T A Q E 5 0 B /5A T A Q E 5 0 B /5A T A Q E 5 0 B /5A T A Q E 5 0 B /5A T A Q E 5 0 B /5A T A Q E 5 0 B /5A T A Q E 5 0 B /5A T A Q E 5 0 B 0 0 0/5A T A Q E TAQ NT72 T A Q C 5 0 A /5A T A Q C 5 0 B /5A T A Q C 5 0 B /5A T A Q C 5 0 B /5A T A Q C 5 0 B /5A T A Q C 5 0 B /5A T A Q C 5 0 B /5A T A Q C 5 0 B /5A T A Q C 5 0 B 0 0 0/5A T A Q C 5 0 B /5A T A Q C 5 0 B /5A T A Q C 5 0 B 0 0 0/5A T A Q C 5 0 C /5A T A Q C 5 0 C /5A T A Q C 5 0 C /5A T A Q C 5 0 C 1 0 /5A T A Q C 5 0 C /5A T A Q C 5 0 C /5A T A Q C 5 0 C /5A T A U C T A Q C TAU11 NT71 T A U C 5 0 D /5A T A U D 5 0 D /5A T A U D 5 0 D /5A T A U D 5 0 D /5A T A U D 5 0 D /5A T A U D 5 0 D /5A T A U D 5 0 D /5A T A U D 5 0 D /5A T A U D TAU12 NT1 T A U E 5 0 D /5A T A U E 5 0 D /5A T A U E 5 0 D /5A T A U E 5 0 D /5A T A U E 5 0 D /5A T A U E 5 0 D /5A T A U E TAU13 NT T A U F 5 0 D /5A T A U F 5 0 D /5A T A U F 5 0 D /5A T A U F 5 0 D /5A T A U F 5 0 D /5A T A U F 5 0 D /5A TAQ2 NT72 T A Q A 5 0 A /5A T A Q A 5 0 B /5A T A Q A 5 0 B /5A T A Q A 5 0 B /5A T A Q A 5 0 B /5A T A Q A 5 0 B /5A T A Q A 5 0 B /5A T A Q A 5 0 B /5A T A Q A 5 0 B 0 0 0/5A T A Q A 5 0 B /5A T A Q A 5 0 B /5A T A Q A 5 0 B 0 0 0/5A T A Q A TAQ NT727 T A Q B 5 0 A /5A T A Q B 5 0 B /5A T A Q B 5 0 B /5A T A Q B 5 0 B /5A T A Q B 5 0 B /5A T A Q B 5 0 B /5A T A Q B 5 0 B /5A T A Q B 5 0 B /5A T A Q B 5 0 B 0 0 0/5A T A Q B 5 0 B /5A T A Q B 5 0 B /5A T A Q B 5 0 B 0 0 0/5A T A Q B 5 0 C /5A TAQ NT72 T A Q D 5 0 A /5A T A Q D 5 0 B /5A T A Q D 5 0 B /5A T A Q D 5 0 B /5A T A Q D 5 0 B /5A T A Q D 5 0 B /5A T A Q D 5 0 B /5A T A Q D 5 0 B /5A T A Q D 5 0 B 0 0 0/5A T A Q D 5 0 B /5A T A Q D 5 0 B /5A T A Q D 5 0 B 0 0 0/5A T A Q D 5 0 C /5A T A Q D 5 0 C /5A T A Q D 5 0 C /5A T A Q D 5 0 C 1 0 /5A T A Q D 5 0 C /5A T A Q D 5 0 C /5A T A Q D 5 0 C /5A T A Q D 5 0 C /5A T A Q D 5 0 C /5A T A Q D 5 0 C /5A T A Q D T A U F T A Q B Accessories sealable terminal cover for TAU/TAU/TAU11/TAU12/TAU13 A T A C O P 0 5 sealable terminal cover for TAQ1/TAQ2/TAQ A T A C O P 0 sealable terminal cover for TAQ A T A C O P 0 3 sealable terminal cover for TAQ A T A C O P 0 7 fixing on Rail Din for TAQ1/TAQ2/TAQ A T A D I N 0 1 protection CT secondary winding opening A T A P
15 Current Transformers Measuring Open core Current Transformers Measuring Summation TRA11 NT721 T A A A 5 0 C /5A T A A A 5 0 C /5A T A A A 5 0 C /5A T A A A 5 0 C /5A T A A A 5 0 C /5A T A A A 5 0 C /5A T A A A 5 0 C /5A T A A A 5 0 C /5A T A A A 5 0 C /5A T A A A 5 0 C /5A T A A A 5 0 D /5A T A A A 5 0 D /5A T A A A 5 0 D /5A T A A A 5 0 D /5A TRA12 NT42 T A C /5A T A C /5A T A C /5A T A D /5A T A D /5A T A D /5A T A BSA02 NT731 T A E A T A E A BSA03 NT731 T A E A T A E A /5A* 1+1/1A* 5+5+5/5A* 1+1+1/1A* TRA NT722 T A A B 5 0 C /5A T A A B 5 0 C /5A T A A B 5 0 C /5A T A A B 5 0 C /5A T A A B 5 0 C /5A T A A B 5 0 C /5A T A A B 5 0 C /5A T A A B 5 0 C /5A T A A B 5 0 C /5A T A A B 5 0 C /5A T A A B 5 0 D /5A T A A B 5 0 D /5A T A A B 5 0 D /5A T A A B 5 0 D /5A T A A B 5 0 D /5A T A A B 5 0 D /5A T A A B 5 0 D /5A T A A B 5 0 D /5A TRA1R NT1 T A A F 5 0 D /5A T A A F 5 0 D /5A T A A F 5 0 D /5A T A A F 5 0 D /5A T A A F 5 0 D /5A BTA2 NT732 T A E B T A E B T A E B T A E B T A E B T A E B T A E B T A E B T A E B T A E B A* 5+5+5A* A* A* A* 1+1A* 1+1+1A* A* A* A* TRA50 NT41 T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A C /5A T A D /5A T A * Input from current transformers with the same ratio. For different ratioes Accessories sealable terminal cover for TRA50/TRA12 A T A C O P 1 3 sealable terminal cover for BSA02/BSA03 A T A C O P 1 1 protection CT secondary winding opening A T A P
16 Current Transformers Accuracy Cable/passing bar TA327 NT2 T A C S 1/5A T A C 1 0 S /5A T A C S 0/5A T A C S 2/5A T A C S 0/5A T A C S 0/5A T A C S 0/5A T A C 0 0 S 00/5A T A TA432 NT T A C S 0/5A T A C S 2/5A T A C S 0/5A T A C S 0/5A T A C S 0/5A T A C 0 0 S 00/5A T A C S 700/5A T A C S 7/5A T A C 0 0 S 00/5A T A D S 0/5A T A TAS5 NT31 T A S L 5 0 C 0 0 S 00/5A T A S L 5 0 C S 700/5A T A S L 5 0 C S 7/5A T A S L 5 0 C 0 0 S 00/5A T A S L 5 0 D S 0/5A T A S L 5 0 D S /5A T A S L 5 0 D S 12/5A T A S L 5 0 D S /5A T A S L 5 0 D 1 0 S 0/5A T A S L 5 0 D S 00/5A T A S L T A S L S TAS4 NT32 T A S O 5 0 C 0 0 S 00/5A T A S O 5 0 D S 0/5A T A S O 5 0 D S /5A T A S O 5 0 D S 12/5A T A S O 5 0 D S /5A T A S O 5 0 D 1 0 S 0/5A T A S O 5 0 D S 00/5A T A S O 5 0 D S 20/5A TAS2 NT33 T A M P 5 0 D S 0/5A T A M P 5 0 D S /5A T A M P 5 0 D S 12/5A T A M P 5 0 D S /5A T A M P 5 0 D 1 0 S 0/5A T A M P 5 0 D S 00/5A T A M P 5 0 D S 20/5A T A M P 5 0 D S 00/5A T A M P T A M P S TAS127 NT34 T A S R 5 0 D S 0/5A T A S R 5 0 D S /5A T A S R 5 0 D S 12/5A T A S R 5 0 D S /5A T A S R 5 0 D 1 0 S 0/5A T A S R 5 0 D S 00/5A T A S R 5 0 D S 20/5A T A S R 5 0 D S 00/5A T A S R T A S R S TAS127B NT35 T A S S 5 0 D S /5A T A S S 5 0 D 1 0 S 0/5A T A S S 5 0 D S 00/5A T A S S 5 0 D S 20/5A T A S S 5 0 D S 00/5A T A S S 5 0 D S /5A T A S S 5 0 D S 00/5A T A S S T A S S S Current Transformers Accuracy Wound primary TAQ2 NT24 T A Q A 5 0 A S 5/5A T A Q A 5 0 B S /5A T A Q A 5 0 B S /5A T A Q A 5 0 B S /5A T A Q A 5 0 B S 25/5A T A Q A 5 0 B S /5A T A Q A 5 0 B S /5A T A Q A 5 0 B S /5A T A Q A 5 0 B 0 0 S 0/5A T A Q A TAQ NT25 T A Q B 5 0 A S 5/5A T A Q B 5 0 B S /5A T A Q B 5 0 B S /5A T A Q B 5 0 B S /5A T A Q B 5 0 B S 25/5A T A Q B 5 0 B S /5A T A Q B 5 0 B S /5A T A Q B 5 0 B S /5A T A Q B 5 0 B 0 0 S 0/5A T A Q B TAQ NT2 T A Q C 5 0 A S 5/5A T A Q C 5 0 B S /5A T A Q C 5 0 B S /5A T A Q C 5 0 B S /5A T A Q C 5 0 B S 25/5A T A Q C 5 0 B S /5A T A Q C 5 0 B S /5A T A Q C 5 0 B S /5A T A Q C 5 0 B 0 0 S 0/5A T A Q C 5 0 B S 70/5A T A Q C 5 0 B S /5A T A Q C 5 0 B 0 0 S 0/5A T A Q C 5 0 C S /5A T A Q C 5 0 C S 1/5A T A Q C 5 0 C S 1/5A T A Q C T A S O T A S O S Accessories sealable terminal cover for TA327/TA432 A T A C O P 1 3 sealable terminal cover for TAS5/TAS4/TAS2/TAS127/TAS127B A T A C O P 0 4 sealable terminal cover for TAQ2/TAQ A T A C O P 0 sealable terminal cover for TAQ A T A C O P 0 3 fixing on Rail Din for TAQ2/TAQ A T A D I N 0 1 protection CT secondary winding opening A T A P
17 Current Transformers Protection Cable/passing bar TAS3P NT45 T A W A 5 0 C /5A T A W A 5 0 C /5A T A W A 5 0 C /5A T A W A 5 0 C /5A T A W A 5 0 C /5A T A W A 5 0 C /5A T A W A 5 0 C /5A T A W A 5 0 C /5A T A W A 5 0 D /5A T A W A 5 0 D /5A T A W A 5 0 D /5A T A W A 5 0 D /5A T A W A 5 0 D 1 0 0/5A T A W A TAS0 NT571 T A S M 5 0 C /5A T A S M 5 0 C /5A T A S M 5 0 C /5A T A S M 5 0 C /5A T A S M 5 0 C /5A T A S M 5 0 C /5A T A S M 5 0 C /5A T A S M 5 0 D /5A T A S M 5 0 D /5A T A S M 5 0 D /5A T A S M 5 0 D /5A T A S M 5 0 D 1 0 0/5A T A S M 5 0 D /5A T A S M 5 0 D /5A T A S M TAS0P NT572 T A W B 5 0 C /5A T A W B 5 0 C /5A T A W B 5 0 C /5A T A W B 5 0 C /5A T A W B 5 0 C /5A T A W B 5 0 C /5A T A W B 5 0 C /5A T A W B 5 0 D /5A T A W B 5 0 D /5A T A W B 5 0 D /5A T A W B 5 0 D /5A T A W B 5 0 D 1 0 0/5A T A W B 5 0 D /5A T A W B 5 0 D /5A T A W B TAS2BP NT7 T A P Q 5 0 C /5A T A P Q 5 0 D /5A T A P Q 5 0 D /5A T A P Q 5 0 D /5A T A P Q 5 0 D /5A T A P Q 5 0 D 1 0 0/5A T A P Q 5 0 D /5A T A P Q 5 0 D /5A T A P Q 5 0 D /5A T A P Q 5 0 D /5A T A P Q 5 0 D /5A T A P Q T A P Q TAS125 NT5 T A S Q 5 0 C /5A T A S Q 5 0 C /5A T A S Q 5 0 C /5A T A S Q 5 0 C /5A T A S Q 5 0 C /5A T A S Q 5 0 C /5A T A S Q 5 0 D /5A T A S Q 5 0 D /5A T A S Q 5 0 D /5A T A S Q 5 0 D /5A T A S Q 5 0 D 1 0 0/5A T A S Q 5 0 D /5A T A S Q 5 0 D /5A T A S Q 5 0 D /5A T A S Q 5 0 D /5A T A S Q TAS125P NT57 T A W C 5 0 C /5A T A W C 5 0 C /5A T A W C 5 0 C /5A T A W C 5 0 C /5A T A W C 5 0 C /5A T A W C 5 0 C /5A T A W C 5 0 D /5A T A W C 5 0 D /5A T A W C 5 0 D /5A T A W C 5 0 D /5A T A W C 5 0 D 1 0 0/5A T A W C 5 0 D /5A T A W C 5 0 D /5A T A W C 5 0 D /5A T A W C 5 0 D /5A T A W C TAU1P NT7 T A X A 5 0 D /5A T A X A 5 0 D /5A T A X A 5 0 D /5A T A X A 5 0 D /5A T A X A 5 0 D /5A T A X A TAU1P NT71 T A X B 5 0 D /5A T A X B 5 0 D /5A T A X B 5 0 D /5A T A X B 5 0 D /5A T A X B 5 0 D /5A T A X B 5 0 D /5A T A X B TAU1P NT71 T A X C 5 0 D /5A T A X C 5 0 D /5A T A X C 5 0 D /5A T A X C 5 0 D /5A T A X C 5 0 D /5A T A X C 5 0 D /5A T A X C 5 0 D /5A T A X C TAU111P NT7 T A X D 5 0 D /5A T A X D 5 0 D /5A T A X D 5 0 D /5A T A X D 5 0 D /5A T A X D 5 0 D /5A T A X D 5 0 D /5A T A X D 5 0 D /5A T A X D 5 0 D /5A T A X D TAU121P NT21 T A X E 5 0 D /5A T A X E 5 0 D /5A T A X E 5 0 D /5A T A X E 5 0 D /5A T A X E 5 0 D /5A T A X E 5 0 D /5A T A X E Accessories sealable terminal cover for TAS3P/TAS0/TAS0P/TAS125/TAS125P A T A C O P 0 3 sealable terminal cover for TAS2BP A T A C O P 0 4 sealable terminal cover for TAU1P/TAU1P/TAU1P/TAU111P/TAU121P/TAU131P A T A C 0 P 0 5 protection CT secondary winding opening A T A P TAU131P NT22 T A X F 5 0 D /5A T A X F 5 0 D /5A T A X F 5 0 D /5A T A X F 5 0 D /5A T A X F 5 0 D /5A T A X F 5 0 D /5A T A X F
18 Current Transformers Protection Wound primary TAQP NT23 T A V B 5 0 A /5A T A V B 5 0 B /5A T A V B 5 0 B /5A T A V B 5 0 B /5A T A V B 5 0 B /5A T A V B 5 0 B /5A T A V B 5 0 B /5A T A V B 5 0 B /5A T A V B 5 0 B 0 0 0/5A T A V B 5 0 B /5A T A V B 5 0 B /5A T A V B 5 0 B 0 0 0/5A T A V B 5 0 C /5A T A V B 5 0 C /5A T A V B 5 0 C /5A T A V B 5 0 C 1 0 /5A T A V B 5 0 C /5A T A V B 5 0 C /5A T A V B 5 0 C /5A Voltage Transformers Measuring/Protection BTV3 NT733 T V V A C C /V T V V A C C /V T V V A C C /V T V V A C C /V T V V A C C /V T V V A C C /V T V V A C C /V T V V A C C /V T V V A C C /V T V V A C 0 0 C /V T V V AG G 1 00 ratio: 3 BTV NT73 T V V D C C /V T V V D C C /V T V V D C C /V T V V D C C /V T V V D C C /V T V V D C C /V T V V D C C /V T V V D C C /V T V V D C C /V T V V D C 0 0 C /V T V V D C 0 C /V T V V D C 0 C /V T V V D C C /V T V V D C 0 0 C /V T V V DD1 0 0 C /V T V V DG G1 00 ratio: 3 (up to 00V) T V V DH1 00 G ratio: 3 (0V) T A V B TAQP NT7 T A V A 5 0 A /5A T A V A 5 0 B /5A T A V A 5 0 B /5A T A V A 5 0 B /5A T A V A 5 0 B /5A T A V A 5 0 B /5A T A V A 5 0 B /5A T A V A 5 0 B /5A T A V A 5 0 B 0 0 0/5A T A V A 5 0 B /5A T A V A 5 0 B /5A T A V A 5 0 B 0 0 0/5A T A V A 5 0 C /5A T A V A 5 0 C /5A T A V A 5 0 C /5A T A V A 5 0 C 1 0 /5A T A V A 5 0 C /5A T A V A 5 0 C /5A T A V A 5 0 C /5A T A V A 5 0 C /5A T A V A 5 0 C /5A T A V A 5 0 C /5A T A V A BTV NT734 T V V B C C /V T V V B C C /V T V V B C C /V T V V B C C /V T V V B C C /V T V V B C C /V T V V B C C /V T V V B C C /V T V V B C C /V T V V B C 0 0 C /V T V V B G G 0 BTV NT735 ratio: 3 T V V C C C /V T V V C C C /V T V V C C C /V T V V C C C /V T V V C C C /V T V V C C C /V T V V C C C /V T V V C C C /V T V V C C C /V T V V C C 0 0 C /V T V V C G G1 00 ratio: 3 BTV NT737 T V V E C C /V T V V E C C /V T V V E C C /V T V V E C C /V T V V E C C /V T V V E C C /V T V V E C C /V T V V E C C /V T V V E C C /V T V V E C 0 0 C /V T V V E C 0 C /V T V V E C 0 C /V T V V E C C /V T V V E C 0 0 C /V T V V E D1 0 0 C /V T V V E G G1 00 ratio: 3 (up to 00V) T V V E H1 0 0 G ratio: 3 (0V) BTV NT73 T V V F C C /V T V V F C C /V T V V F C C /V T V V F C C /V T V V F C C /V T V V F C C /V T V V F C C /V T V V F C C /V T V V F C C /V T V V F C 0 0 C /V T V V F C 0 C /V T V V F C 0 C /V T V V F C C /V T V V F C 0 0 C /V T V V F D1 0 0 C /V Accessories sealable terminal cover for TAQP A T A C O P 0 3 sealable terminal cover for TAQP A T A C O P 0 7 protection CT secondary winding opening A T A P sealable terminal cover for BTV/BTV/BTV/BTV/BTV A T V C O P 0 1 T V V FG G ratio: 3 (up to 00V) T V V FH1 00G ratio: 3 (0V) 2
19 Voltage Transformers Accuracy BTV NT3 T V V B C C S 2/V T V V B C C S 2/V T V V B C C S 0/V T V V B C C S 4/V T V V B C C S 4/V T V V B C C S 0/V T V V B C 0 0 C S 00/V T V V BG G 0S BTV NT3 ratio: 3 T V V C C C S 2/V T V V C C C S 2/V T V V C C C S 0/V T V V C C C S 4/V T V V C C C S 4/V T V V C C C S 0/V T V V C C 0 0 C S 00/V BTV NT3 T V V E C C S 2/V T V V E C C S 2/V T V V E C C S 0/V T V V E C C S 4/V T V V E C C S 4/V T V V E C C S 0/V T V V E C 0 0 C S 00/V T V V E C 0 C S 0/V T V V E C 0 C S 0/V T V V E C C S 700/V T V V E C 0 0 C S 00/V T V V E D C S 0/V T V V EG G 1 0 0S ratio: 3 (up to 00V) T V V EH G S ratio: 3 (0V) T V V CG G S ratio: 3 BTV NT73 T V V D C C S 2/V T V V D C C S 2/V T V V D C C S 0/V T V V D C C S 4/V T V V D C C S 4/V T V V D C C S 0/V T V V D C 0 0 C S 00/V T V V D C 0 C S 0/V T V V D C 0 C S 0/V T V V D C C S 700/V T V V D C 0 0 C S 00/V T V V D D C S 0/V T V V D G GS ratio: 3 (up to 00V) T V V DHG1 0 0S ratio: 3 (0V) BTV NT T V V F C C S 2/V T V V F C C S 2/V T V V F C C S 0/V T V V F C C S 4/V T V V F C C S 4/V T V V F C C S 0/V T V V F C 0 0 C S 00/V T V V F C 0 C S 0/V T V V F C 0 C S 0/V T V V F C C S 700/V T V V F C 0 0 C S 00/V T V V FD1 0 0 C S 0/V T V V FG GS ratio: 3 (up to 00V) T V V FHGS ratio: 3 (0V) Accessories sealable terminal cover for BTV/BTV/BTV/BTV/BTV A T V C O P
20 Via Travaglia 7 04 CORSICO (MI) Tel Fax [email protected] 04/13 700
LOW-VOLTAGE CURRENT TRANSFORMERS
LOWVOLTAGE CURRENT TRANSFORMERS 5 A Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) 45 75 39; 45 75 305; 45 75 3; 45 75 368; email: [email protected] ul. Słubicka 657 Zielona Góra CONTENTS
Current transformers (CT) & Shunts
Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar
Measurement devices Accessories for analogue and digital instruments
Accessories for analogue and digital instruments 1 2CSC96F0001 Current transformers Used to transform primary currents (max. 6000 A) into.../5 A and.../1 A low secondary currents indirectly supplying power
Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,
Accessories Temperature Sensors for Injection Molding Types 6192B, 6193B, 6194B, 6195B Temperature sensors for measuring the contact temperature directly in the cavity at the surface of the solidified
CURRENT TRANSFORMERS INSTALLATION GUIDE
CURRENT TRANSFORMERS INSTALLATION GUIDE Information contained within this document is subject to change without notice and does not represent a commitment on the part of PRI Ltd or its agents. E&OE. Copyright
keep your measure under control
INSTRUMENTACIÓN INDUSTRIAL ZURC, S.A. keep your measure under control CURRENT For measuring instruments. Mounted in selfexinguishing, plastic, strengthened cases. Isolation voltage V Made as per UNEEN
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
Measurement and Instrumentation
POWER QUALITY ENERGY PERFORMANCE Measurement and Instrumentation Transformers and shunts Transformers Overview of ranges Selection guide Info & advice Standard industrial transformers TCR TCRO ranges Adaptable
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Digital display DA 48
Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
Static energy meters
Static energy meters 2.01 Model Conto D1 Conto D2-b Codes CE11165A0 CE11165A2 CE21175A0 Ordering codes see page: 09 09 09 Connection on line single-phase single-phase Active energy class 1 EN62053-21 class
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Model CU100: non-invasive installation flowmeter, with transducers installed outside the pipe Installation in horizontal or vertical pipe Easy and
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
CT Current transformers Ideal for measuring. Designed to create efficiency.
CT Current transformers Ideal for measuring. Designed to create efficiency. CT Current transformers Optimize consumptions. Improve the efficiency. Energy efficiency, minimized costs and high system availability
NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES
NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
Vario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Medium-voltage transformers
Medium-voltage transformers We make energy measurable and take care of your future www.mbs-ag.com Page 2 E-Mail: [email protected] Web: www.mbs-ag.com Contents Current transformers Technical characteristics
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
Relay mounting systems
Page 1 Issued July 1998 Changed since April 1997 Data subject to change without notice RL COMBIFLEX RE 500 (SE 94832) (SE 970140) (SE 950216) Features Suitable for standard 19 rack, flush, semiflush, projection
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Current Transformers
Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 Current Transformers Current transformers (CT's) provide
Horns. Buzzers 6.02-6.03, 6.06. Compressed air horns 6.09-6.10. Disc-type horns 6.05-6.06. Electric twin-tone horns 6.08
Buzzers 6.02-6.03, 6.06 Compressed air horns 6.09-6.10 Disc-type horns 6.05-6.06 Electric twin-tone horns 6.08 6.03-6.04 Supertone horns 6.07 6 EE 07 6.01 Part no. Pk. Buzzers With bracket, Two 6.3 mm
Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Current & Instrument Transformers
Reliable & Accurate Inputs for Measuring & Protection Equipment Current & Instrument Transformers Type MKE11 Inside the Catalogue Range Specifications Ordering Code Delivering Value to You M-Kris Electric
Reaction Torque Sensor
Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.
Mounting Instructions. Torque Transducer. A0329 3.2 en
Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
Dear Customer! Thank you for choosing our product.
Dear Customer! Edition 1.4 Thank you for choosing our product. MIDI AMP CONTROLLER MAC-4.4 is an adaptor that enables to control (switch the channels, switch on/off other functions) the amps equipped with
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially
3-Component Measuring System
Force 3-omponent Measuring System for utting Force Measurement During Turning Modular system for measurement of cutting forces when turning outside and inside diameters on turret lathes. Machine adapters
INSTALLATION INSTRUCTIONS: Viewline 52 mm
-5 Safety information The product was developed, manufactured and inspected according to the basic safety requirements of EC Guidelines and state-of-the-art technology. The instrument is designed for use
Description. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
Mounting instructions. Junction box VKK2R-8 DIGITAL. A1145-1.0 en
Mounting instructions Junction box VKK2R-8 DIGITAL VKK2R-8 DIGITAL 3 Contents Page Safety instructions... 4 1 Introduction and appropriate use... 7 2 Mechanical construction... 8 2.1 Mounting... 9 3 Electrical
How To Choose A Transformer
Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
CONFIGURABLE SAFETY RELAYS
MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional
mecotron Safety relay ESTOP-2 For emergency stop monitoring
E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated
E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51
83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE
The following components are common to most cubicles; this example is an ABB HK cubicle.
4.0 CIRCUIT BREAKER CUBICLE Learning Objectives The circuit breaker cubicle is the component of the switchgear that holds the circuit breaker, and the controls and cabling for the distribution system.
Tape Wound, Split Core and Ebony Current Transformers
Tape Wound, Split Core and Ebony Current Transformers Current Transformers Contents Page Tape Wound Measuring and Protection Current Transformers 2 6 Split Core Current Transformers 7 9 3-in-1 Current
Technical note NT588 NT604 NT695 NT782
Multifunction 1.01 Model Nemo D4-b Nemo D4-L Nemo D4-L+ Codes MF6GT MF6FT0 MF6FTU MF6FT4 MF6HTU... MF6HT4... MF6HB... Ordering codes see page: 08 08 08 08 08 08 08 Connection on line single phase, 3-phase
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Electro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
Maximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
Decorative Metal Wiring Accessories in Assorted Plate Finishes
Decorative Metal Wiring Accessories in Assorted Plate Finishes Switches Power Socket Outlets 13A Fused Connection Units Control Switches TV Telephone Data Sockets Deco unique product codes Decorative Metal
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
C13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19
C13 C13 Document ID: 2CMC486004M0201 2013-06-19 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment
KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB
KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor Type Cable Current Transformers Index Description... 3 Technical
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
RVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
3 3RG78 45 program overview
Overview RG78 45 light curtains and arrays with integrated processing unit for type 4 in accordance with IEC/EN 61496 With "Standard" function package Resolutions: 14, 0, 50, and 90 Protective zone height:
EM-PQ 1500 Power Quality Monitor. Operating Manual
EM-PQ 1500 Power Quality Monitor Operating Manual 1 User notes: 2 Contents Page Page 1. Quick start... 5 2. Description... 6 2.1 Operating principle... 6 3. Installation... 8 3.1 Mounting... 8 3.2 Electrical
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution
UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,
Tamura Closed Loop Hall Effect Current Sensors
Tamura Closed Loop Hall Effect Current Sensors AC, DC, & Complex Currents Galvanic Isolation Fast Response Wide Frequency Bandwidth Quality & Reliability RoHs Compliance Closed Loop Hall Effect Sensors
Content 02/ MIG/MAG AUTOMATION. Torch heads. MIG/MAG (up to 350 A) MET 35x/39x 2. MIG/MAG (up to 450 A) MET 32xx/37xx/39xx 6
Content 02/ Torch heads MIG/MG (up to 350 ) MET 35x/39x 2 MIG/MG (up to 450 ) MET 32xx/37xx/39xx 6 MIG/MG (up to 550 ) METZ 52x/59x/54x/56x/57x 12 MIG/MG (up to 350 ) METZ 58xx 22 MIG/MG (up to 450 ) METZ
AMERICAN BOSCH WIPER MOTOR Double-speed, Automatic zero setting ( left or right ) SHORT or LONG pivot. Pivot length mm. Wiping angle regolabile
Chapter 17th Windscreen wiper motors Pendulum arms Pantograph arms Blades for flat screens Blades for curved screens Control panels Windscreen wipers 351 Windscreen wipers WIPER MOTOR AFI 2000 For heavy
PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v
Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
E-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.
Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly
UNIVERSAL RAILING, STEEL
RAILINGS Page Universal Railing, steel 108-109 Large Module Railing, steel 110-111 Allround Railing, aluminium 112-113 Module Railing, aluminium 114-115 Standard Type Railing, aluminium 116-117 107 UNIVERSAL
LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS
Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEB Standard 027: 1998 CEYLON
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures
NEW RANGE OF CABINETS DRIVIATM Innovation at your service THE GLOBAL SPECIALIST in electrical and digital building infrastructures Drivia true innovation The new electrical panel for the residential and
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Circuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
Guide to Safety Edge Systems
Guide to Safety Edge Systems Tel: 0845 054 5070 [email protected] Guide to Safety Edges All new automatic gate & door systems installed in the UK should comply to BS-EN13241-1 & EN-138491-1 harmonised
Thermometer in stainless steel with capillary and switch contacts
Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy
Current and Energy. Measurement Technology
Current and Energy Measurement Technology Current Measurement and Evaluation WAGO s Solution for Energy Monitoring and Conservation Rogowski Coils, 855 Series Conversion of AC currents up to 500 A/2000
Typical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
SENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 [email protected] www.valcontrols.
HARDWARE MANUAL Ixx24-A 1/20 Table of contents 1 General... 3 1.1 Safety instructions... 3 1.2 Environment... 3 1.3 Mounting and dimension... 3 2 Communication... 4 2.1 Control loop AI0 and Transmitter