Version
|
|
|
- Camilla McBride
- 9 years ago
- Views:
Transcription
1 Version English
2 Table of contents 1. Introduction Intended Use Dangers caused by Electric Current General Safety Instructions System Requirements SFP Transceiver Compatibility 7 2. Device Overview Front Panel Rear Panel LED Indicators Factory Defaults First Steps Unpack the Device Install Mini-GBIC (SFP) Installation in a Rack Connect the Hardware Set the IP Address on the PC Access the Web Interface Display Navigation Groups View Workload View Reset View Ports / Groups Change Port Description Assign Groups to Ports Edit RSTP Edit Speed Setting Change Group Name Edit IGMP Snooping Edit IGMP Querier Edit Unknown Flooding Change VLAN ID Presets / Filters Assign Presets to Ports 35 2
3 6.2. Apply Filters to Ports Create New Presets Update Presets Create New Filter View Filter Data Delete Presets Delete Filter General Settings Change Name Change ID Change DHCP Client Change IP Address Change Subnet Mask Change Default Gateway Change Password Update Firmware Fallback to Backup Firmware Get Switch Configuration Upload Switch Configuration Reset Settings Specifications Support Glossary Index 65 3
4 1. Introduction The MA Network Switch is the perfect device for a full lighting control solution. The combination of console, switch and networking devices provides the easiest solution even for complex lighting systems. Designed to simplify the set-up and management of today s lighting networks, the MA Network Switch is backed by the industry leading MA technical support team. Standard lighting terminology is used allowing most common lighting protocols to be filtered via a web interface designed specifically for lighting technicians. The tiered interface also allows advanced functionality for experienced network engineers. The MA Network Switch provides a local display for port status, applied filters and recognized MA equipment. Additionally it shows workload status of the switch and every single port for easier fault finding. The MA network switch is compliant with IEEE 802.3ab Gigabit Ethernet and can be seamless integrated into existing Ethernet networking infrastructures. The ability to define port filtering with the common entertainment protocols combined with standard Ethernet protocols like IGMP and RSTP allow the switch to perform best in fixed installation as well as in temporary installations. The MA Network Switch is housed in a typically robust 1RU chassis, with color coded filter and data indicators front and rear. The front panel features a single ethercon port and display screen. The rear panel incorporates 8 ethercon ports and 2 SFP cages to suit mini-gbic fiber connections. Additionally, the MA Network Switch can be fitted with 2 optional heavy duty fiber connections for extended cable runs! The following figure displays how a MA network with a MA Network Switch could look like in principle. 4
5 Figure: Principle Network Schematic 1.1. Intended Use The MA Network Switch is intended to be operational right out of the box as a standard switch. In the default configuration, it will forward packets between connecting devices after power up. Every other use is not intended and could follow personal injury and damage to property. MA Lighting does not cover damages which can result of a not intended use of the console Dangers caused by Electric Current 5
6 1.2. Dangers caused by Electric Current If the device or the power cable is damaged, there is a risk of death by an electrical shock. Follow the safety instructions to avoid the risks by electric current. Do not use a damaged power cable. Do not open screwed covers from the body housing. Use the device only, if it is in a technical perfect condition. A broken device can be repaired only by an authorized serviced personal. Do not repair the device by your own. Do not make changes on the device, its components, and accessories. Do not expose the device to rain or moisture. Do not dive the device in water General Safety Instructions Follow the safety instructions, to avoid physical injury or material damage: Do not grab inside the device during it is running. The device and the power cable needs to keep away from children below 8 years. Children are not allowed to play with the device. Do not use any liquid or spray cleanser. Use a dry cloth. Do not block or cover any ventilation slots in the housing - they are necessary for the essential airflow within the unit and protect it against overheating. Place the device on stable surfaces only. If it is placed on unstable surfaces, it may fall and become damaged System Requirements To use the web interface, your browser should have the following requirements: Microsoft Internet Explorer 11 Mozilla Firefox 40 Google Chrome 45 Apple Safari 8 To use the online help manual, you need internet access SFP Transceiver Compatibility 6
7 1.5. SFP Transceiver Compatibility The following SFPs transceivers are tested and compatible with the MA Network Switch. Cisco MGBT1 Gigabit 1000 Base-T Mini-GBIC SFP Transceiver Cisco MGBSX1 Gigabit SX Mini-GBIC SFP Transceiver Cisco GLC-SX-MM Emcore Finisar FTRJ8519P1BNL-B1 Finisar FTLF8519P2BNL 7
8 2. Device Overview The following chapter gives you an overview about the device of the MA Network Switch Front Panel 13 x Link LEDs 13 x Group LEDs 1 x 10/100/1000 Mbps shielded Neutrik ethercon connector 1 x Power LED 1 x Status LED 1 x Menu Button 1 x Front End Display 2.2. Rear Panel 8
9 2.2. Rear Panel 2 x Optical Fiber Connectors (optional) 2 x Optical Fiber Link LEDs 2 x Optical Fiber Group LEDs 1 x USB2 Type B connector 2 x SFP cage for Mini-Gbic complaint transceiver (external) 2 x SFP cage for Mini-Gbic complaint transceiver (internal) 2 x Mini-Gbic Link LEDs 2 x Mini-Gbic Group LEDs 8 x 10/100/1000 Mbps shielded Neutrik Ethercon connectors 8 x ethercon Link LEDs 8 x ethercon Group LEDs 1 x powercon Connector 2.3. LED Indicators 9
10 2.3. LED Indicators The following tables shows the LED indicators for the MA Network Switch along with the explanation of each indicator. Power LED Status Off Green Red blink Status LED Status Green Green blink Red Link LED Status Off Green blink Orange blink Meaning No power Power supply OK Error Meaning All OK Update Error Meaning No link Gigabit connection 10/100 Mbps connection Group LED Status Meaning Red Group 1 Yellow Group 2 Green Group 3 Cyan Group 4 Blue Group 5 Magenta Group 6 White Trunk Off Manage 2.4. Factory Defaults The following tables describes the factory defaults and what will happen to various settings when you reset the switch. 10
11 If you want to reset the switch, refer to General Settings - Reset Settings. General Settings Defaults This table describes the general settings defaults and what will happen to the general settings when you reset the switch. Reset mode Reset ALL settings to factory default by using the web interface - and - Hard reset with the menu button at the front panel Items affected Reset IP address to the default IP address, displayed at the front end display. The default IP address is always the factory-given IP address per device. Reset subnet mask to Reset default gateway to Reset password to "admin" Reset name to "MA Switch" Reset ID to "1" IGMP Snooping "No" IGMP Querier "No" Unknown Flooding "Yes" Disable filters Disable speed RSTP enabled All ports are manage ports Preset Defaults The following lists describes what preset includes what filters by default and what will happen to the presets when you reset the switch. Preset MA-Net2 The preset MA-Net2 contains the following filters by default: MA-Net2 crtl IPv4 MA-Net2 data IPv4 Preset dot2-net The preset dot2-net contains the following filters by default: dot2-net wing data dot2-net wing 11
12 dot2-net wing ctrl dot2-net ctrl IPv6 dot2-net data IPv6 Preset Art-Net The preset Art-Net contains the following filters by default: Art-Net Preset MA-Remote The preset MA-Remote contains the following filters by default: HTTPS (dport 443) HTTPS (sport 443) HTTP (dport 80) HTTP (sport 80) MA Webremote (dport 8080) MA Webremote (sport 8080) MA Remote (7003) MA Remote (7002) MA Remote (7001) Preset MA-Net1 The preset MA-Net1 contains the following filters by default: MA-Net Preset grandma2 The preset grandma2 contains the following filters by default: PSN DNS NTP SSH (dport 22) SSH (sport 22) syslog AVAHI SNMP trap SNMP KiNet Art-Net sacn MA-Net2 ctrl IPv4 MA-Net2 data IPv4 12
13 MIDI Show Control VPU remote (dport 7005) VPU remote (sport 7005) VPU remote (dport 7004) VPU remote (sport 7004) HTTPS (dport 443) HTTPS (sport 443) HTTP (dport 80) HTTP (sport 80) MA Webremote (dport 8080) MA Webremote (sport 8080) MA Remote (7003) MA Remote (7002) MA Remote (7001) Telnet (dport 30000) Telnet (sport 30000) Telnet (dport 23) Telnet (sport 23) nmbd (tcp) nmbd (udp) SMB (tcp 139) SMB (udp 138) SMB (udp 137) NFS (tcp) NFS (udp) FTP CITP MA CITP ShowNet PathPort ETC Net2 Preset sacn The preset sacn contains the following filters by default: sacn Filter Defaults The following tables describes what filters exist by default along with their frame match and what will happen to the filters when you reset the switch. Filter Frame Match PSN Standard IPv4 UDP dport
14 Filter Frame Match DNS IPv4 UDP dport NTP IPv4 UDP dport 123 SSH (dport 22) IPv4 TCP sport 22 SSH (sport 22) IPv4 TCP dport 22 syslog IPv4 UDP dport 514 AVAHI IPv4 UDP dport 5353 SNMP trap IPv4 UDP dport 162 SNMP IPv4 UDP dport 161 KiNet IPv4 UDP dport 6038 Art-Net IPv4 UDP dport 6454 sacn IPv4 UDP dport 5568 MA-Net2 ctrl IPv4 IPv4 UDP dport MA-Net2 data IPv4 IPv4 UDP dport dot2-net wing data IPv6 UDP dport dot2-net wing IPv6 UDP dport dot2-net wing ctrl IPv6 UDP dport dot2-net ctrl IPv6 IPv6 UDP dport dot2-net data IPv6 IPv6 UDP dport MIDI Show Control IPv4 UDP dport range MA-Net IPv4 UPD dport 9138 VPU remote (dport 7005) TCP dport 7005 VPU remote (sport 7005) TCP sport 7005 VPU remote (dport 7004) TCP dport 7004 VPU remote (sport 7004) TCP sport 7004 HTTPS (dport 443) IPv4 TCP sport 443 HTTPS (sport 443) IPv4 TCP dport 443 HTTP (dport 80) IPv4 TCP sport 80 HTTP (sport 80) IPv4 TCP dport 80 MA Webremote (dport 8080) IPv4 TCP dport 8080 MA Webremote (sport 8080) IPv4 TCP sport 8080 MA Remote (7003) TCP dport 7003 MA Remote (7002) TCP dport 7002 MA Remote (7001) TCP dport 7001 Telnet (dport 30000) TCP dport Telnet (sport 30000) TCP sport Telnet (dport 30001) TCP dport Telnet (sport 30001) TCP sport Telnet (dport 23) TCP dport 23 Telnet (sport 23) TCP sport 23 nmbd (tcp) IPv4 TCP dport 445 nmbd (udp) IPv4 UDP dport 445 SMB (tcp 139) TCP dport 139 SMB (udp 138) UDP dport 138 SMB (udp 137) UDP dport
15 Filter Frame Match NFS (tcp) TCP dport 111 NFS (udp) UDP dport 2049 FTP TCP dport 21 CITP MA TCP dport CITP UDP dport 4809 ShowNet UDP dport 2501 PathPort UDP dport 3792 ETC Net2 UDP dport
16 3. First Steps This chapter describes, how to prepare the MA Network Switch for usage Unpack the Device Unpack the MA Network Switch. Remove all packing material, strips and protection films. Keep the packing material for transport Install Mini-GBIC (SFP) The MA Network Switch comes with up to four SFP cages. These cages accept mini-gbic transceivers. Two are at the rear panel, port 9 and 10. Two are inside the MA Switch. To install mini-gbic transceivers inside the switch at port 11 and port 12, call your local distributor. Install mini-gbic at port 9 and Remove the mini-gbic from its protective packaging. Be aware of the insertion direction. Port 9 must have the bail wire delatch on the top. Port 10 must have the bail wire delatch at the bottom. 2. Install the mini-gbic into the slot 9 or 10 at the rear panel, until the mini-gbic clicks into place. For detailed description of your mini-gbic transceiver, refer to the transceiver manual. Remove mini-gbic from port 9 and Open the ball wire delatch to disengage and remove the mini-gbic transceiver. 2. Replace the protective plastic cover on the mini-gbic. The mini-gibc is removed from the port Installation in a Rack 16
17 3.3. Installation in a Rack The MA Network Switch is 1U high and will fit in most standard 19-inch racks. 1. Insert the switch into the 19-inch rack and secure with suitable screws. Ensure the ventilation holes are not obstructed. 2. Connect the switch to the power supply. 3. Connect the cables. The MA Network Switch is installed in a rack Connect the Hardware Requirement: Shielded twisted pair cable with RJ45 connector, min. Cat 5e - or - ethercon cable with Neutrik ethercon connector. Connection with a PC 1. Plug in the power cable into the switch. The switch starts booting. 2. Plug in a network cable into one of the Ethernet ports of the switch. For the PC connection and for further configuration, you have to use a manage group port. We recommend port 13 at the front. 3. Plug in the other end of the network cable into the Ethernet port on the PC. A green or orange link LED on the switch indicates a successful connection. The MA Network Switch is connected with the PC. Connection with a grandma2 1. Plug in the power cable into the switch. The switch starts booting. 2. Plug in a network cable into one of the Ethernet ports of the switch. 3. Plug in the other end of the network cable into the Ethernet port 1 of the grandma2 console. A green or orange link LED on the switch indicates a successful connection. The MA Network Switch is connected with the grandma Set the IP Address on the PC 17
18 3.5. Set the IP Address on the PC The default IP address of the switch is a xxx. It is displayed at the front end display. The default subnet mask of the switch is This means your PC must be temporarily set to a compatible IP address. 1. Unplug the computer from the Local Area Network (LAN). 2. Go to the Control Panel on the computer. 3. Go to Network and Sharing Center and click on Change adapter settings. 4. Right-click the connection for your LAN, and then click Properties. If you re prompted for an administrator password or confirmation, type the password or provide confirmation. 5. Click the Networking tab. Under This connection uses the following items, click Internet Protocol Version 4 (TCP/IPv4), and then click Properties. 6. Select Use the following IP address and enter a compatible IP address e.g and the default subnet mask The PC is set to a compatible IP address Access the Web Interface Use these steps to access the web interface home page for the switch. Requirements: 18
19 Power (indicates by a green power LED) Hardware connection between the MA Switch and a computer (indicates by a green or orange blinking link LED) 1. Open the web browser. 2. Type the switch IP address in the address bar. Hint: The IP address is displayed at the front end display in the upper right corner. The username and password dialog box opens. 3. Type as username administrator. 4. Type the first time as password admin. Important: It is recommended to change the password after the first login. The status page of web interface opens. 19
20 Figure: Start Screen Web Interface 20
21 4. Display Navigation The display offers basic information about the MA Network Switch. There are two different information screens available and the reset screen. To change the view, press the menu button Groups View The groups view is visible after booting the MA Network Switch. Figure: Groups View The groups view displays the assigned group of each port in the group color. The title bar displays the assigned switch name and the IP address. If presets or filter are applied to a port, the filter icon is next to group name. If RSTP (Rapid Spanning Tree Protocol) is disabled from a port, a red R is next to the group name. If a MA device is detected by a port, the white heart is next to the group name. The white heart indicates incoming MA-Net2. In bottom right corner the version number is displayed Workload View 21
22 4.2. Workload View To open the workload view at the front end display, press the menu button. Figure: Workload View In the title bar is the switch load and the network load in percent. The switch load displays how much the CPU of the switch is used at the moment. A high percentage means that the web interface or processes that are running require a lot of CPU resources, which can slow down your switch. The network load in the title bar displays the average load of every connected ports. The percentage and the green load bar on every port, displays the in and out total network load per port. In bottom right corner the version number is displayed Reset View 22
23 4.3. Reset View To open the reset view, press and hold the menu button for about 5 seconds. The reset view opens. Figure: Reset View To reset the switch to its factory defaults, follow the display instructions. For more information, see Edit General Settings - Reset Settings. 23
24 5. Ports / Groups This chapter provides information about ports / groups options provided through the web interface. For information about how access the web interface, refer to First Steps - Access the Web Interface Change Port Description To have a better overview about what is connected to what port you can change the port description of each port. Change Port Description The port description has a maximum length of 8 characters. The following characters are allowed. Upper case letters A...Z Lower case letters a...z Numbers Spaces, minus (-), plus (+), underscore (_) Requirement: Connection to the web interface. 1. Click Edit Ports / Groups. 2. Type the port description in the description box below the port number. 3. Click Apply settings and stay where you are or Apply settings and leave edit. The port description is applied and saved in the startup configuration. The port description is visible in the web interface overview Assign Groups to Ports 24
25 5.2. Assign Groups to Ports You can assign one group for each port. Two devices must be part of the same group to communicate. Groups are a logical segment of network users (= VLAN). With groups it is possible to send different signals in different groups via the same network cable without affect the other signal. For example sound and light signals. The groups for port 1 through 13 can be manually configured at the Edit Ports / Groups Window. By default, all groups are managed groups. The assigned group has a green dot. The switch has eight different groups. 1. Group01 (Red) 2. Group02 (Yellow) 3. Group03 (Green) 4. Group04 (Cyan) 5. Group05 (Blue) 6. Group06 (Magenta) 7. Trunk (White) 8. Manage (Gray) If more than one switch is in a network and more than one group is in use, the Trunk is needed to forward all group packets to the other switches. The Trunk bundles all other groups. Important: You need at least one manage group in the network. If no manage port is in the network, you can not configure the switch anymore. A factory reset is necessary. Hint: Use port 13 on the front panel as management port to connect the PC for switch configuration via the web interface. Assign Groups 25
26 Requirement: Connection to the Web Interface. 1. Click Edit Ports / Groups. 2. Click on the Group you want to assign to the port. The green dot is visible next to the group. 3. Click Apply settings and stay where you are or Apply settings and leave edit. The selected group is assigned to the port and saved in the startup configuration. The group LED at the front panel indicates the assigned group in the group color Edit RSTP Rapid Spanning Tree Protocol (RSTP) uses point-to-point wiring and provides rapid convergence of the spanning tree. If there are more than one point-to-point connections between two switches, RSTP manages the redundant link unless the original connection fails. Important: The MA Network Switch support an implementation of RSTP that is compatible with the IEEE 802.1w standard and does not support per VLAN RSTP. This means that the MA Network Switch will send out and expect to receive untagged RSTP messages. Figure 1: Edit RSTP By default, RSTP is enabled. Disabled = Red dot The switch does not run RSTP for this port. If RSTP is disabled, LLDP (Link Layer Discovery Protocol) is disabled as well. Enabled = Green dot The switch runs RSTP for this port. If RSTP is enabled, LLDP (Link Layer Discovery Protocol) is enabled as well. Requirement: Connection to the web interface. 1. Click Edit Ports / Groups. 2. Click in the RSTP box for that port you want to enable or disable. 3. Click Apply settings and stay where you are or Apply settings and leave edit. RSTP is enabled or disabled for the selected port and saved in the startup configuration. Example Let s assume, you have two connected MA Network Switches with two Trunk ports by accident. If you have more than one connection between two devices, RSTP is necessary. If RSTP is would be disabled in that example, there is no connection. 26
27 5.4. Edit Speed Setting You can edit the port speed of each port on the MA Network Switch. The selected speed is visible at the status page on the web interface. If a port is connected, the link LED is blinking in the speed color. Refer to, LED Indicators. There are three speed settings available: Auto: The port detects automatically the speed of the connected device (default). 100Mbit 1Gbit Requirement: Connection to the web interface. 1. Click Edit Ports / Groups. 2. Click on the speed you want to select, e.g. 1Gbit. The green dot displays the current settings. 3. Click Apply settings and stay where you are or Apply settings and leave edit. The selected speed is applied and saved in the startup configuration Change Group Name 27
28 5.5. Change Group Name You can change the group name of every group except Trunk and Manage. For a better overview every group name is displayed in a different color. Important: The group name is a label for better overview and does not affect the VLAN. Edit Ports / Groups - Group Names Requirement: Connection to the web interface. 1. Click Edit Ports / Groups. 2. In the group names column, delete the old group name and type a new group name. 3. Click Apply settings and stay where you are or Apply settings and leave edit. The new group name is applied and saved in the startup configuration Edit IGMP Snooping 28
29 5.6. Edit IGMP Snooping IGMP snooping avoids ports to be flooded with undesired multicast packets. It is a smart way to manage multicast packets, and forward them to the registered ports. IGMP snooping is disabled by default. Hint: To forward only known multicast network packets, enable IGMP Snooping and IGMP Querier. Disable unknown flooding. Requirement: Connection to the web interface. 1. Click Edit Ports / Groups. 2. Click in the IGMP Snooping column, that box you want to enable or disable. 3. Click Apply settings and stay where you are or Apply settings and leave edit. IGMP snooping is enabled or disabled for the selected group, and saved in the startup configuration Edit IGMP Querier 29
30 5.7. Edit IGMP Querier Important: IGMP snooping requires at least one switch in a group (VLAN) to act as a querier, to ensure IGMP snooping functionality. Querier register the multicast packets to the corresponding ports. If more than one querier is activated per group, the switch with the lowest IP address will be elected as querier. This election process is automated. IGMP querier is disabled by default. Requirement: Connection to the web interface. 1. Click Edit Ports / Groups. 2. Click in the IGMP Querier column, that box you want to enable or disable. 3. Click Apply settings and stay where you are or Apply settings and leave edit. IGMP querier is enabled or disabled for the selected group and saved in the startup configuration Edit Unknown Flooding 30
31 5.8. Edit Unknown Flooding Unknown flooding is for multicasted frames destined for an address for which the switch has not seen a join. In that case the switch uses the flooding mask to forward that frame to every port. Unknown flooding can be global enabled or disabled for all groups. By default, unknown flooding is enabled. Yes = All unknown packages will be forwarded No = All unknown packages will be dropped Hint: To forward only known multicast network packets, enable IGMP Snooping and IGMP Querier. Disable unknown flooding. Requirement: Connection to the web interface. 1. Click Edit Ports / Groups. 2. Click in the column unknown flooding at the gray box. 3. Click Apply settings and stay where you are or Apply settings and leave edit. Unknown flooding is enabled or disabled and saved in the startup configuration Change VLAN ID 31
32 5.9. Change VLAN ID All groups of the switch have a default VLAN ID, except Trunk. If you implement the switch in an existing network, it can be necessary to change the VLAN ID of the groups. You can change the VLAN ID of group 1 through group 6. The VLAN ID of group 8 (= manage group) is 1 and fixed. Possible VLAN IDs are from 1 to Group Default VLAN ID Important: If you change the VLAN ID of a group, you need to change the VLAN ID of each switch using this group. The VLAN IDs of the groups which should communicate to each other, have to be the same. If the VLAN IDs of groups are not the same, they do not communicate with each other. Requirement: Connection to the web interface. 1. Click Edit Ports / Groups. 2. Click edit right beside VLAN ID. The VLAN IDs are editable. 3. In the VLAN ID column, delete the old VLAN ID of the group you want to change, and type in a new VLAN ID. 4. Click Apply settings and stay where you are or Apply settings and leave edit. The new VLAN ID for the group is applied and saved in the startup configuration. 32
33 6. Presets / Filters This chapter provides information about the preset and filter options provided trough the web interface. What are presets? It is useful to apply presets or filters to ports for a higher network performance or for safety reasons, e.g. to block Telnet. A preset contains collection of filters. Presets are used to allow or to block the selected output. If a preset is set to allow (= green), the network packets matching the filters in the preset are allowed. All other network packets not matching the filters of this preset, will be blocked. If a preset is set to block (= red), the network packets matching the filters in the presets are blocked. All other network packets not matching the filters of this preset, will be allowed. Important: Filter will be only applied for outbound network traffic of the specific physical connector. There are seven predefined presets available: MA-Net2 dot2-net Art-Net MA-Remote MA-Net1 grandma2 sacn Important: Use presets only if a filter function is required. If you use the MA Network Switch in a MA System it is not mandatory to use the grandma2 preset. For more information, see apply presets. For more information about the predefined presets, see factory defaults. What are filters? Instead of using presets, you can use filters. For more information, see apply filters. Filters are objects consisting of: data type addressing further parameters depending on the data type 33
34 There are 43 predefined filters available. To get an overview about the predefined filters, go to the extended mode in the web interface. For more information about the predefined filters, see factory defaults. If you are a network configuration expert, you can create new presets and new filters. For more information, see create new preset and create new filter. The following table displays the always forwarded filters to provide basic network functionality. These filter cannot be blocked. Filter Frame Match IPMCv6 IPv6 next-header 58 IPMCv4 IPv4 protocol nr 1 (ICMP) IGMP IPv4 protocol nr 2 (IGMP) DHCP client IPv4 UDP port 68 DHCP IPv4 UDP port 67 ARP arp 6.1. Assign Presets to Ports 34
35 6.1. Assign Presets to Ports You can assign one preset per port. For general information about presets, see What are presets?. Figure: Edit Presets Requirement: Connection to the Web Interface. 1. Click Edit Presets. Information: If manual filters are assigned to a port, you have to remove the filters first to assign a preset. You can identify that manual filters are assigned, if the presets are written in grey font. 2. To block the output, click once on a preset. Displayed by a red status dot. To allow the output, click twice on a preset. Displayed by a green status dot. 3. Click Apply settings and stay where you are or Apply settings and leave edit. The preset is assigned and saved in the startup configuration. A filter icon is displayed right beside the group name in the front end display. The assigned preset is visible in the web interface overview in green or red, depending on the selected status. To remove a preset from a port, click on the preset until the status dot is grey. To create a new preset, see Create New Presets Apply Filters to Ports Instead of apply presets to ports you can also apply filters to ports. If a filter is set to allow, all other network packets not matching this filter, will be blocked. 35
36 Requirement: Connection to the Web Interface. 1. Click Edit Presets. 2. Scroll down to the end of the page and click in the bottom right corner Extended filter and preset config. Figure 1: Access Extended Mode The extended mode opens. Figure 2: Extended Mode Information: To change the filter status from blocked to allow output or vice versa, you need to change the preset status. Hint: If allow output only is selected, all network packets matching the filter port will be forwarded. If a protocol needs more than one port, you have to apply multiple filters. 36
37 3. To change if the filter should allow the output (displayed by a green color) or block the output (displayed by a red color), click on the preset number or preset name in the header. Figure 3: Filters Applied 4. Select the filters for the port by clicking. If a preset was assigned to the port, the preset changes to filters applied. 5. Click Apply settings and stay where you are or Apply settings and leave edit. The selected filters are applied and saved in the startup configuration. A filter icon is visible right beside the group name on the front display. To create new filter, see Create New Filter Create New Presets You can create up to 24 new presets additional to the 7 predefined presets. If you need more customized presets than 24, you can delete the 7 predefined presets and create in total 31 customized presets. A created preset contains the applied filters. If you use the same filter assignment frequently, you should save the filter assignment as a preset. Requirement: Applied Filters to Ports. Information: The new preset will be applied for the selected port after saving. 37
38 1. Click at the end of the filter list Save as preset. Figure 1: Extended Mode - Save as Preset 2. The save presets pop-up opens. Figure 2: Save Presets 3. Enter a name for the new preset, e.g. Telnet All. 4. Click Create preset. The new preset is created and applied for the selected port. The new preset is saved in the startup configuration.a filter icon is visible right beside the group name on the front end display Update Presets 38
39 6.4. Update Presets You can modify the filter assignment for existing preset and update them. Requirement: Applied preset to a port. 1. Click Edit Presets and then click Extended filter and preset config. 2. Modify the filter assignment for the preset in the assigned port column. 3. Click Save as preset at the end of the port column. The save presets pop-up opens. Figure: Update Preset 4. Select in the drop down the preset you want to update. 5. Click Update existing preset. The preset is updated with the new filter assignment and saved in the startup configuration Create New Filter You can create 85 new filters, additional to the 43 predefined filters. Important: The combination of filter name, data type and addressing must be unique for each filter. If this data are not unique, it is not possible to create a new filter. Open Edit Filters pop-up 39
40 Open Edit Filters pop-up Requirement: Connection to the Web Interface. 1. Click Edit Presets. 2. Click at the bottom right corner Extended filter and preset config. 3. Click at the bottom right corner Custom filters. The Edit filter pop-up opens. Figure 1: Edit filters pop-up The edit filters pop-up is open. Create Ethernet Filter To create an Ethernet filter: 40
41 1. Open the Edit Filters pop-up. 2. Enter the Filter name. Each filter name must be unique. The filter name contain letters, numbers, and hyphens (-). 3. Select the Data type Ethernet. 4. Select in the drop down if the Addressing is - Any - Unicast - Multicast - Broadcast 5. Enter the Ethertype. Valid Ethertypes are - 0x600-0x7ff - 0x801-0x805-0x807-0x86dc - 0x86de - 0xfff 6. Click Create filter. The Ethernet filter is created and visible the end of the filter tables. The filter is saved in the startup configuration. Create IPv4 UDP Filter or IPv4 TCP Filter Information: The mask is used to determine the range of the IP destination. Example 1: IP destination: IPv4 mask: All packets send to IP address match the filter. Example 2: IP destination: IPv4 mask: All packets send to IP address match the filter. To create an IPv4 UDP filter or IPv4 TCP filter: 1. Open the Edit Filters pop-up. 2. Enter the Filter name. Each filter name must be unique. The filter name contain letters, numbers, and hyphens (-). 3. Select the Data type. IPv4 UDP or IPv4 TCP. 4. Select in the drop down if the Addressing is - Any - Unicast - Multicast - Broadcast 5. Select the DPort type (= destination port type). Choose between Single Port or Port Range. 6. Enter the DPort (= destination port number). Valid port numbers are between Enter the IPv4 destination. 41
42 8. Enter the IPv4 mask. 9. Click Create filter. The IPv4 UDP or TCP filter is created and visible the end of the filter tables. The filter is saved in the startup configuration. Create IPv6 UDP Filter or IPv6 TCP Filter To create an IPv6 UDP filter or IPv6 TCP filter: 1. Open the Edit Filters pop-up. 2. Enter the Filter name. Each filter name must be unique. The filter name contain letters, numbers, and hyphens (-). 3. Select the Data type. IPv6 UDP or IPv6 TCP. 4. Select in the drop down if the Addressing is - Any - Unicast - Multicast - Broadcast 5. Select the DPort type (= destination port type). Choose between Single Port or Port Range. 6. Enter the DPort (= destination port number). Valid port numbers are between Click Create filter. The IPv6 UDP or TCP filter is created and visible the end of the filter tables. The filter is saved in the startup configuration. Create ARP Filter To create an ARP filter: 1. Open the Edit Filters pop-up. 2. Enter the Filter name. Each filter name must be unique. The filter name contain letters, numbers, and hyphens (-). 3. Select the Data type ARP. 4. Select in the drop down if the Addressing is - Any - Unicast - Multicast - Broadcast 5. Click Create filter. The ARP filter is created and visible the end of the filter tables. The filter is saved in the startup configuration. Paste Filter Configuration If you already have a filter configuration for a new filter, you can paste the configuration data into the field. 42
43 Important: You have to use the same style as it is displayed in the configuration data field. Write the configuration in one row. If you are using new lines, the configuration can not be applied. Requirement: Open edit filters pop-up. 1. Paste the configuration data into the field. 2. Click Create filter. The filter is created and visible at the end of the filter tables. The filter is saved in the startup configuration View Filter Data If you are not sure what data a filter has, you can view the filter data of the existing filters. Requirement: Connection to the Web Interface. 1. Click Edit Presets. 2. Scroll down to the end of the page and click Extended filter and preset config. 43
44 3. Scroll down to the end of the page and click Custom filters. The Edit filters pop-up opens. Figure 1: Edit Filters pop-up 4. Select the filter you want to view in the drop down. 5. Click View filter. A pop-up opens what displays the filter data. 44
45 Figure 2: View Filter pop-up 6.7. Delete Presets 45
46 6.7. Delete Presets If you created presets that you no longer use or need, delete them. You can delete previous created presets and the predefined presets. Warning: After you delete a customized presets, you can not restore them. The predefined presets can be restored by a factory reset. Requirement: Connection to the Web Interface. 1. Click Edit Presets. 2. Click in the bottom right corner Extended filter and preset config. Figure 1: Access Extended Mode The extended mode opens. 3. Click in the bottom right corner Delete presets. The delete presets pop-up opens. Figure 2: Delete Presets Pop-Up 4. Select in the drop down the preset you would like to delete and click Delete preset. A warning asks if you really want to delete this preset. Click OK. The preset is deleted from the startup configuration. If the deleted preset was applied to a port, the filters in the preset are still applied to this port Delete Filter If you have created custom filters that you no longer use or need, you can delete them. 46
47 You can delete custom filters and predefined filters. Warning: After you delete a customized filter, you can not restore them. The predefined filters can be restored by a factory reset. Requirement: Connection to the Web Interface. 1. Click Edit Presets. 2. Scroll down to the end of the page and click Extended filter and preset config. 3. Scroll down to the end of the page and click Custom filters. The Edit filters pop-up opens. Figure: Edit Filters pop-up 4. Select the filter you want to the delete in the drop down. 47
48 5. Click Delete filter. A warning asks if you really want to delete this filter. Information: If the filter you tried to delete is contained in a preset, a warning asks if you want to delete this filter anyway. 6. Click OK. The selected filter is deleted from the startup configuration. 48
49 7. General Settings The following topics describe how to edit the general settings of the MA Network Switch. Figure: Edit General Settings 7.1. Change Name 49
50 7.1. Change Name You can change the name of the MA Network Switch. The name is displayed at the front end display and in the title bar of the web interface. The maximum length of the name are 12 characters. The following characters are allowed. Upper case letters A...Z Lower case letters a...z Numbers Spaces, minus (-), plus (+), underscore (_) Requirement: Connection to the web interface. 1. Click Edit General Settings. 2. Enter the new name, e.g. Stage Left. 3. Click Apply settings and stay where you are or Apply settings and leave edit. The new name is applied and saved in the startup configuration. The front end display and the title bar of the web interface displays the new name Change ID The ID is used for better identification in the network. You can change the ID of the MA Network Switch. The allowed characters are Requirement: Connection to the web interface. 1. Click Edit General Settings. 2. Enter the new ID, e.g Click Apply settings and stay where you are or Apply settings and leave edit. The MA Network Switch has a new ID. The new ID is saved in the startup configuration Change DHCP Client 50
51 7.3. Change DHCP Client If the network is equipped with a DHCP server, enable the DHCP client of the switch, for it to receive automatically an IP address from the DHCP server. If DHCP is enabled, the settings for static IP address, static subnet mask, and the static default gateway, are not changeable anymore. The previous assigned IP address will be used if there is no DHCP server available. Requirement: Connection to the web interface. 1. Click Edit General Settings. 2. Click under DHCP client enabled or disabled. 3. Click Apply settings and stay where you are or Apply settings and leave edit. The DHCP client is enabled or disabled. The DHCP settings are saved in the startup configuration Change IP Address You can change the IP address of the MA Network Switch. The IP address will be used to reach the web interface. The current IP address is displayed at the upper right corner of the front display and in the title bar of the web interface. Important: If you change the IP address and the new IP address is within another subnet, it is necessary to set the IP address on your computer to connect to the web interface. If the computer and the switch are in different subnet, the connection to the web interface is not possible. Important: Make sure that every device in the network has its unique IP address. If two devices have the same IP address in a network, the devices might not be reachable. Requirement: Connection to the web interface. 1. Click Edit General Settings. 2. Type the new IP address in the IP address field. 3. Click Apply settings and stay where you are or Apply settings and leave edit. The new IP address is displayed at the front end display of the switch. The IP address is changed and saved in the startup configuration. To access the web interface, type the new IP address in the address field of the browser and press Enter Change Subnet Mask 51
52 7.5. Change Subnet Mask You can change the subnet mask of the MA Network Switch. The subnet mask is used to determine where the network number in an IP address ends and the device number in and IP address begins. Example: IP address: Subnet mask: The network number is The device number is 129. All devices in the network need to have the same first three blocks, and the last block needs to be different. Requirement: Connection to the web interface. 1. Click Edit General Settings. 2. Type the subnet mask in the subnet mask field. 3. Click Apply settings and stay where you are or Apply settings and leave edit. The new subnet mask is applied and saved in the startup configuration Change Default Gateway You can change the default gateway of the MA Network Switch. The default gateway IP address is If your network has no specified gateway leave the IP address in it. Requirement: Connection to the web interface. 1. Click Edit General Settings. 2. Type the default gateway in the default gateway field. 3. Click Apply settings and stay where you are or Apply settings and leave edit. The new default gateway is applied and saved in the startup configuration Change Password You can change the password of the MA Network Switch. The password is necessary to login into the web interface. The default password is admin. 52
53 Figure 1: Change Password The following characters are allowed. Upper case letters A...Z Lower case letters a...z Numbers Spaces, minus (-), plus (+), underscore (_) Requirement: Connection to the web interface. 1. Click Edit General Settings. 2. Click Change password. 3. Type the old password, type the new password, type the new password again to confirm it, and then click Apply new password. The new password is applied and saved in the startup configuration. The Authentication Required pop-up opens. Figure 2: Authentication Required 4. Type the new password and click OK. The password is changed and you are logged in with the new password. 53
54 If you have forgotten the password, you can reset the password to the default by a factory reset Update Firmware You can update the firmware of the MA Network Switch. The current firmware is displayed at the bottom right corner at the front end display of the switch and in the web interface. Download the latest version of the switch at Requirement: Connection to the web interface. 1. Download the latest firmware at and save it. 2. Click Edit General Settings. 3. Click Update firmware. 4. Click Browse and select the.update file of the new firmware. 5. Click Upload and install. The switch is updating and reboots. This can take up to 5 minutes Fallback to Backup Firmware 54
55 7.9. Fallback to Backup Firmware You can downgrade the firmware of the MA Network Switch to the previous firmware version. The current firmware is displayed at the bottom right corner at at the front end display of the switch and at in the web interface. We recommend, that the switches in the same network always runs the same firmware. Requirement: Connection to the web interface. 1. Click Edit General Settings. 2. Click Update firmware. 3. Click Fallback to this firmware. A warning asks if you want to restore the current firmware to the backup firmware. 4. Click OK. The MA Network Switch is installing the backup firmware and reboots Get Switch Configuration 55
56 7.10. Get Switch Configuration The configuration is the customized set of parameters that you have selected to run the switch. You can export the current switch configuration for later import. This is useful if the same configuration must be used in multiple switches. Requirement: Connection to the web interface. 1. Click Edit General Settings. 2. Click Switch configuration. 3. Click Get the current switch configuration. A browser window opens. 4. Click Save File and OK. Depending on the browser settings, the browser asks to choose the folder. You can also rename the file. The switch configuration is downloaded and saved as a config.json file or the given file name, for later upload. For more information to the upload, see Upload Switch Configuration Upload Switch Configuration You can upload a previous exported switch configuration, or parts of switch configuration. This is useful if you have to configure several switches with the same configuration. 56
57 Figure 1: Switch Configuration Important: The configuration file has to be written in a JSON (JavaScript Object Notation) data format. If it is not in a JSON data format, the switch can not read the configuration file. Hint: If you are not sure how to write the configuration file, get the current switch configuration and modify this file. Important: If you upload only parts of switch configuration, e.g. only the filters, it is necessary that the entire filters configuration part is included in the configuration file. If parts are missing in the configuration file, the configuration upload does not work. Requirement: Connection to the web interface. 1. Click Edit General Settings. 2. Click Switch configuration. 3. Click Browse. The explorer opens. 4. Select the switch configuration for upload. 5. Click Upload and apply custom configuration. A warning asks if you really want to apply the configuration. 57
58 6. Click OK. The switch configuration is uploading. The update screen opens. Figure 2: Update Screen The update process can take about 60 seconds. 7. Follow the screen instructions and click Reload. The switch configuration is uploaded and saved in the startup configuration Reset Settings 58
59 7.12. Reset Settings By resetting the MA Network Switch, you return the switch to the state it was in when it was first time powered. This is useful for troubleshooting problems that might be caused by manual changes after first time powered. Refer to, factory defaults for a complete list of all settings and information they are reset. Resetting the MA Switch is not reversible. After a reset, all previous settings are lost and cannot be recovered. Use the Web Interface Requirement: Connection to the web interface. 1. Click Edit General settings. 2. Click Reset ALL settings to factory defaults. A warning asks if you are really sure to reset to factory default. 3. Click OK. It might take a little while for the process to complete. The MA Network Switch restarts. All settings are set back to the factory defaults. Use the Menu Button 1. Press the menu button on the switch for at least 5 seconds until the reset screen appears. 2. Press the menu button again for at least 5 seconds until the booting screen appears. The MA Network Switch turns off and restarts. All settings are set back to the factory defaults. 59
60 8. Specifications Connectivity Network Power 9 x 10/100/1000 Mbps shielded Neutrik ethercon connectors 1 on the front, 8 at the rear 4 SFP cages (mini-gbic) 2 at the rear, 2 inside the MA Network Switch 1 x Neutrik powercon In Switch Features RSTP Yes Groups (=VLANs) Yes Fan 2 IEEE 802.3, IEEE 802.3u, IEEE Ethernet Compliance 8023x Flow Control, IEEE 802.3ab Gigabit Ethernet Supported Protocols Sound Protocol Compliance Ethernet Switch Type Memory MAC Address Table Address Learning / Aging Switching Throughput IGMP Support IGMP Snooping MA-Net2, MA-Net, sacn, Art-Net, and many more. IEEE 802.1p CoS (Class of Service) DiffServ (DSCP) IEEE 1588 PTP V2 Yes, Low jitter Full non blocking wire-speed switching performance 4Mb 8912 Entries Self learning, Auto aging 32Gbps Yes Yes Port Features 60
61 Port Features Port Sensing Auto Crossover Auto Sensing Auto negotiation MDI / MDIX (allow to use straight or cross wired cable) Full or Half Duplex (Gigabit is Full Duplex) Status Reports Front End Display Ethernet Port Connection Ethernet Port Speed Device Power Yes Link, Group 100/1000Mbps LED Status LED (Green/Red) Status LED (Green/Red) Management Configuration Through the web interface. Power Input Power Input Power Consumption VAC 50-60Hz Maximum 1A Environmental Operating Temperature Storage Temperature Humidity (non condensing) 0 C to +45 C 32 F to 113 F -10 C to +60 C 14 F to 140 F 20% to 80% relative humidity Physical 61
62 Physical Enclosure Dimensions (W x D x H) Weight without optical fiber connector Weight with optical fiber connector Metal housing 483 x 233 x 43 mm 19" x 9,17" x 1,69" 3,5 kg 7.7 pounds 3,7 kg 8.2 pounds Approvals CE EN EN EN RoHS Compliance Yes Yes Yes Yes Yes 62
63 9. Support Access the Help To access the help, click at the bottom right corner in the web interface, with no internet access, click Help (PDF). The help pdf opens. with internet access, click Online help. The online help opens. MA System Specialist Training To become a MA System Specialist visit the MA University. The MA System Specialist Training gives you information about complex networking constructions e.g. with lighting panels, specifics of the MA system, or specifics of networks in the lighting world, see the MA System Specialist Training. Technical Service and Support MA Lighting and its extensive distributor network offer an unparalleled technical service. Call on our expertise for help with any problem, no matter if it is regarding operation, software features, software installations or trouble shooting. Please send an (in English or German) to tech.support(at)malighting.com with your contact details and subject information. This service is monitored during MA Lighting's regular business hours in Germany from 8.30 a.m. until 5 p.m., Monday through Friday. For emergency services please contact your local MA distributor or the MA Lighting Service Hotline. Call: Please note, this 24/7 hotline is strictly for emergency cases for people being in trouble out in the field. 63
64 10. Glossary A Art-Net: Art-Net 3 Ethernet communication standard. A protocol for transmitting the lighting control protocol DMX 512-A over the User Datagram Protocol of the Internet Protocol suite. ARP (= Address Resolution Protocol): A telecommunication protocol used for resolution of network layer addresses into link layer addresses, a critical function in multiple-access networks. To create ARP filter, see Create New Filter. D DHCP (Dynamic Host Control Protocol): Is a standardized network protocol used on Internet Protocol (IP) networks for dynamically distributing network configuration parameters, such as IP addresses for interfaces and services. With DHCP, computers request IP addresses and networking parameters automatically from a DHCP server, reducing the need for a network administrator or a user to configure these settings manually. E Ethernet: Is a local network with bus topology, what allows multiply devices access at the same time. It is used for communication between light consoles. G Groups: A logical segment of network users and resources grouped by function, team, or application. This segmentation is without regard to the physical location of the users and resources. Also known as VLAN. I IGMP (Internet Group Management Protocol): A protocol that manages how adapters and other components join and leave multicast groups. IGMP snooping is a feature of IGMP that allows Ethernet switches to look (snoop) inside packets to determine which destinations really need to receive the data. K KiNET: A protocol used by Color Kinetics to control their LED fixtures and power supplies. L LLDP (Link Layer Discovery Protocol): Used by network devices for advertising their identity, capabilities, and neighbors on an IEEE 802 local area network. LLDP will be disabled or enabled along with RSTP. For more information, see Edit RSTP. 64
65 M MA-Net2: Integral part of the MA System architecture. All MA series 2 devices are connected via the MA-Net2 as if they were one device. All of these components contain all system data that is needed to control the processes and to synchronize the outputs in real-time. Mbps (Megabit per second): Unit of data transfer rate. The data transfer rate of the ethercon ports is 10/100/1000 Mbps. Mini-Gbic (Gigabit Interface Converter): A transceiver that converts electric currents (digital highs and lows) to another signal types. Mostly optical signals. The Gbic is typically employed in fiber optic and Ethernet systems as an interface for high-speed networking. The data transfer rate is one gigabit per second (1 Gbps) or more. There are two Mini-Gbic cages at the rear panel and two inside of the MA Network Switch. R RSTP (Rapid Spanning Tree Protocol): Provides significantly faster spanning tree convergence after a topology change, introducing new convergence behaviors and bridge port roles to do this. S sacn (streaming Architecture for Control Networks) ANSI E A protocol to transport DMX512 data over IP networks. SFP (Small form-factor pluggable): A specification for a new generation of optical modular transceivers. The devices are designed for use with small form factor (SFF) connectors, and offer high speed and physical compactness. Spanning Tree: Used with network topologies that provide more than one physical path between two devices, spanning tree protocol manages path redundancies while preventing undesirable loops in the network. If a fault should occur on an active port, the switch will begin transmitting out one of the blocked ports. T Trunk: This is the name given to the interconnection links between switches in a network. The Trunk links are meant to forward the groups based packets. In most case, the Trunk links will be the redundant links. V VLAN (Virtual local-area network): Refer to, Groups. 65
66 11. Index Access the Web Interface 3.6. Apply Filters to Ports 6.2. Apply Presets 6.1. Approvals 8. Assign Groups to Ports 5.2. Assign Preset 6.1. Assign Presets to Ports 6.1. Backup Firmware 7.9. Browser 1.4. Change Default Gateway 7.6. Change DHCP Client 7.3. Change Group Name 5.5. Change ID 7.2. Change IP Address 7.4. Change Name 7.1. Change Password 7.7. Change Port Description 5.1. Change Speed 5.4. Change Subnet Mask 7.5. Change VLAN ID 5.9. Configuration Connect Hardware 3.4. Connection with a grandma Connection with a PC 3.4. Connectivity 8. Create New Filter 6.5. Create Presets 6.3. Custom Filters 6.2. Danger 1.2. Default Gateway 7.6. Default Password 7.7. Defaults 2.4. Delete 6.8. Delete Filter 6.8. Delete Presets 6.7. Description 5.1. Device Overview 2. DHCP 7.3. Display Navigation 4. Edit Filters Pop-Up
67 Edit IGMP Querier 5.7. Edit IGMP Snooping 5.6. Edit RSTP 5.3. Edit Speed Setting 5.4. Edit Unknown Flooding 5.8. Edit VLAN ID 5.9. Electric Current 1.2. Environmental 8. Factory Defaults 2.4. Fallback to Backup Firmware 7.9. Filter Filter Configuration 6.5. Filter Defaults 2.4. Filter Icon 4.1. Filters First Steps 3. Front Panel 2.1. Gateway 7.6. General Safety 1.3. General Settings 7. Get Switch Configuration Glossary 10. Group Configuration 5.2. Group LED 2.3. Group Name 5.5. Groups View 4.1. Hardware Connection 3.4. Heart 4.1. Help 9. ID 7.2. IGMP Querier 5.7. IGMP Snooping 5.6. In 4.2. Install mini-gbic 3.2. Installation in a Rack 3.3. Intended Use 1.1. Introduction 1. IP address 7.4. IPv LED Indicators 2.3. Link LED
68 LLDP 5.3. Load In 4.2. Load Out 4.2. Login 3.6. MA Network Switch Management 8. mini-gbic 3.2. Modify Presets 6.4. Name 7.1. Network Cable 3.4. Network Load 4.2. Network Traffic 4.2. New Presets 6.3. Online Help 9. Out 4.2. Password 7.7. Paste Filter 6.5. Physical 8. Port Port Port Configuration 5.2. Port Description 5.1. Port Features 8. Port Speed 5.4. Ports / Groups 5. Power Input 8. Power LED 2.3. Preset 6.1. Preset Defaults 2.4. Presets 6. Priniciple Network Schematic 1. R 4.1. Rack Installation 3.3. Rapid Spanning Tree Protocol 5.3. Rear Panel 2.2. Remove mini-gbic 3.2. Remove Preset 6.1. Reset 4.3. Reset All Reset Configuration Reset Settings
69 Reset View 4.3. RSTP 5.3. RSTP Default 5.3. RSTP Disabled 5.3. RSTP Enabled 5.3. Safety 1.3. Save Preset 6.3. Save Switch Configuration Set the IP Address on the PC 3.5. SFP 3.2. SFP Module 1.5. SFP Transceiver Compatibility 1.5. Speed Configuration 5.4. Speed Settings 5.4. Status LED 2.3. Status Report 8. STP Transceiver 1.5. Subnet Mask 7.5. Support 9. Switch Configuration Switch Features 8. Switch Load 4.2. Switch Name 7.1. System Requirements 1.4. Technical Service 9. Training 9. Unknown Flooding 5.8. Unpack the Device 3.1. Update 7.8. Update Firmware 7.8. Update Presets 6.4. Upload Switch Configuration View 6.6. View Filters 6.6. VLAN 5.9. VLAN ID 5.9. Web Interface 3.6. What are Filters 6. What are Presets 6. White Heart 4.1. Workload View
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
SonicOS Enhanced 5.7.0.2 Release Notes
SonicOS Contents Platform Compatibility... 1 Key Features... 2 Known Issues... 3 Resolved Issues... 4 Upgrading SonicOS Enhanced Image Procedures... 6 Related Technical Documentation... 11 Platform Compatibility
Chapter 4 Management. Viewing the Activity Log
Chapter 4 Management This chapter describes how to use the management features of your NETGEAR WG102 ProSafe 802.11g Wireless Access Point. To get to these features, connect to the WG102 as described in
Chapter 3 Management. Remote Management
Chapter 3 Management This chapter describes how to use the management features of your ProSafe 802.11a/g Dual Band Wireless Access Point WAG102. To access these features, connect to the WAG102 as described
3.5 EXTERNAL NETWORK HDD. User s Manual
3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility
ProSAFE 8-Port and 16-Port Gigabit Click Switch
ProSAFE 8-Port and 16-Port Gigabit Click Switch Model GSS108E and GSS116E User Manual March 2015 202-11520-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products.
WRE6505. User s Guide. Quick Start Guide. Wireless AC750 Range Extender. Default Login Details. Version 1.00 Edition 1, 4 2014
WRE6505 Wireless AC750 Range Extender Version 1.00 Edition 1, 4 2014 2.4G 5G Quick Start Guide User s Guide Default Login Details LAN IP Address 192.168.1.2 User Name admin www.zyxel.com Password 1234
Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.
IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input
Networking Guide Redwood Manager 3.0 August 2013
Networking Guide Redwood Manager 3.0 August 2013 Table of Contents 1 Introduction... 3 1.1 IP Addresses... 3 1.1.1 Static vs. DHCP... 3 1.2 Required Ports... 4 2 Adding the Redwood Engine to the Network...
CCNA Discovery 4.0.3.0 Networking for Homes and Small Businesses Student Packet Tracer Lab Manual
4.0.3.0 Networking for Homes and Small Businesses Student Packet Tracer Lab Manual This document is exclusive property of Cisco Systems, Inc. Permission is granted to print and copy this document for non-commercial
How To Install An At-S100 (Geo) On A Network Card (Geoswitch)
AT-S100 Version 1.0.3 Patch 1 Management Software for the AT-9000/28 Managed Layer 2 GE ecoswitch and AT-9000/28SP Managed Layer 2 GE ecoswitch Software Release Notes Please read this document before you
Quick Start Guide. Cisco Small Business. 300 Series Managed Switches
Quick Start Guide Cisco Small Business 300 Series Managed Switches Welcome Thank you for choosing the Cisco 300 Series Managed Switch, a Cisco Small Business network communications device. This device
Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches
Quick Start Guide Cisco Small Business 200E Series Advanced Smart Switches Welcome Thank you for choosing the Cisco 200E series Advanced Smart Switch, a Cisco Small Business network communications device.
24 Port Gigabit Ethernet Web Smart Switch. Users Manual
24 Port Gigabit Ethernet Web Smart Switch Users Manual Content Web Smart Switch Configure login -------------------------------- 2 Configuration System Configuration ---------------------------------------------------
Configuration Manual English version
Configuration Manual English version Frama F-Link Configuration Manual (EN) All rights reserved. Frama Group. The right to make changes in this Installation Guide is reserved. Frama Ltd also reserves the
48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W
GEP-5070 Version: 1 48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W The LevelOne GEP-5070 is an intelligent L2 Managed Switch with 48 x 1000Base-T PoE-Plus ports and 2 x 100/1000BASE-X SFP (Small Form
Barracuda Link Balancer
Barracuda Networks Technical Documentation Barracuda Link Balancer Administrator s Guide Version 2.2 RECLAIM YOUR NETWORK Copyright Notice Copyright 2004-2011, Barracuda Networks www.barracuda.com v2.2-110503-01-0503
Deployment Guide: Transparent Mode
Deployment Guide: Transparent Mode March 15, 2007 Deployment and Task Overview Description Follow the tasks in this guide to deploy the appliance as a transparent-firewall device on your network. This
TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module
Panduit Corp. 2010 TDP43ME NetPS PA26306A01 Rev. 01 11-2010 Network Printer Server Control Center for Ethernet Module NOTE: In the interest of higher quality and value, Panduit products are continually
Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business
Quick Start Guide Cisco Small Business WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide Versión en Español para México en el CD Version en français sur CD Versione
Apple Airport Extreme Base Station V4.0.8 Firmware: Version 5.4
1. APPLE AIRPORT EXTREME 1.1 Product Description The following are device specific configuration settings for the Apple Airport Extreme. Navigation through the management screens will be similar but may
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,
AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch. Software Release Notes
AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch Supported Platforms Software Release Notes Please read this document before you begin to use the AT-S60 management software. The AT-S60
ALL8894WMP. User s Manual. 8-Port 10/100/1000Mbps with 4-port PoE. Web Management Switch
ALL8894WMP 8-Port 10/100/1000Mbps with 4-port PoE Web Management Switch User s Manual Content Content I Introduction..3 Product Overview.3 Web Management Feature.3 Specification..4 Mechanical...4 Performance...5
Cisco Small Business Managed Switches
Cisco SRW224P 24-Port 10/100 + 2-Port Gigabit Switch: WebView/PoE Cisco Small Business Managed Switches Secure, Reliable, Intelligent Switching with PoE for Growing Businesses Highlights Connects up to
AT-S41 Version 1.1.4 Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches. Software Release Notes
AT-S41 Version 1.1.4 Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches Software Release Notes Please read this document before you begin to use the AT-S41 management software.
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
GS510TP and GS110T Gigabit Smart Switches
GS510TP and GS110T Gigabit Smart Switches Software Administration Manual 350 East Plumeria Drive San Jose, CA 95134 USA December 2011 202-10883-01 v1.0 2011 NETGEAR, Inc. All rights reserved No part of
PREFACE http://www.okiprintingsolutions.com 07108001 iss.01 -
Network Guide PREFACE Every effort has been made to ensure that the information in this document is complete, accurate, and up-to-date. The manufacturer assumes no responsibility for the results of errors
Ha-VIS FTS 3000 Introduction and features
Ha-VIS Introduction and features Ethernet Switch Ha-VIS FTS 3100s-A 10-port Ethernet Switch with Fast Track Technology configurable via USB General Description Features The Fast Ethernet Switches of the
ADMINISTRATION GUIDE Cisco Small Business
ADMINISTRATION GUIDE Cisco Small Business 200 Series Smart Switch Administration Guide Contents Chapter 1: Getting Started 1 Starting the Web-based Switch Configuration Utility 1 Launching the Configuration
NETWORK PRINT MONITOR User Guide
NETWORK PRINT MONITOR User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable
CM500 High Speed Cable Modem User Manual
User Manual February 2015 202-11472-04 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label
Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)
Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time
GS716Tv3, GS724Tv4, and GS748Tv5 Smart Switches
GS716Tv3, GS724Tv4, and GS748Tv5 Smart Switches Software Administration Manual September 2013 202-11263-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products.
Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA
Quick Start Guide Cisco SPA232D Mobility Enhanced ATA Package Contents Analog Telephone Adapter Ethernet Cable Phone Cable Power Adapter Quick Start Guide Product CD-ROM Welcome Thank you for choosing
Barracuda Link Balancer Administrator s Guide
Barracuda Link Balancer Administrator s Guide Version 1.0 Barracuda Networks Inc. 3175 S. Winchester Blvd. Campbell, CA 95008 http://www.barracuda.com Copyright Notice Copyright 2008, Barracuda Networks
WSG24POE Switch. User Manual
WSG24POE Switch User Manual Version: 01/01/2011 Introduction! 4 Product Overview! 4 Specifications! 5 Package Contents! 5 Hardware Description! 6 Physical Dimensions/ Weight! 6 Front Panel! 6 LED Indicators!
SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
AT-GS950/8. AT-GS950/8 Web Users Guide AT-S107 [1.00.043] Gigabit Ethernet Smart Switch. 613-001484 Rev A
AT-GS950/8 Gigabit Ethernet Smart Switch AT-GS950/8 Web Users Guide AT-S107 [1.00.043] 613-001484 Rev A Copyright 2011 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced
Router Setup Manual. NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17
NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear, Inc. Microsoft, Windows,
Network Probe User Guide
Network Probe User Guide Network Probe User Guide Table of Contents 1. Introduction...1 2. Installation...2 Windows installation...2 Linux installation...3 Mac installation...4 License key...5 Deployment...5
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
VIP-102B IP Solutions Setup Tool Reference Manual
VIP-102B IP Solutions Setup Tool Reference Manual Table of Contents Overview...5 System Requirements for Managed VoIP Products...6 Term Definitions...7 Main Application Window...8 Legend Description...9
IS SERIES. QuikStart Programming Guide. IP Network Direct System. Programming Videos
0215 IS SERIES IP Network Direct System QuikStart Programming Guide 1 4 GHI 2 ABC 5 JKL 3 DEF 6 MNO PRIVACY TRANSFER LIST SETTING 7 PQRS 8 TUV 9 WXYZ ZOOM 0 # WIDE Programming Videos ATTENTION: This is
ProSafe Plus Switch Utility
ProSafe Plus Switch Utility User Guide 350 East Plumeria Drive San Jose, CA 95134 USA December 2012 202-10524-05 NETGEAR, Inc. All rights reserved No part of this publication maybe reproduced, transmitted,
100 240VAC 50/60Hz Power Adapter
DGS-1224T D-Link 24-Port 10/100/1000Mbps + 2 Combo Mini GBIC Gigabit Smart Switch Broadband Router Before Your Begin This Quick Installation Guide gives step-by-step instructions for setting up the D -Link
3.5 Mobile LAN Disk. User Guide
3.5 Mobile LAN Disk User Guide Contents 1. Hardware...2 1.1 Power...2 1.2 Ports...2 1.3 Reset Button...2 1.4 LEDs...2 1.5 Front View...3 1.6 Rear View...3 2. Installation....... 4 2.1 Requirements 4 2.2
AC1600 WiFi VDSL/ADSL Modem Router
AC1600 WiFi VDSL/ADSL Modem Router Model D6400 User Manual May 2015 202-11485-03 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device,
HWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
NeoGate TA Series Installation Guide
NeoGate TA Series Installation Guide Version 1.2 Date: April 1, 2015 Yeastar Information Technology Co. Ltd Contents 1. Preparation before Installation... 3 2. Hardware Specifications... 5 2.1 Overview...
Gigabyte Content Management System Console User s Guide. Version: 0.1
Gigabyte Content Management System Console User s Guide Version: 0.1 Table of Contents Using Your Gigabyte Content Management System Console... 2 Gigabyte Content Management System Key Features and Functions...
Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version 1.1. 613-000368 Rev. B
Management Software AT-S84 User s Guide For the AT-9000/24 Layer 2 Gigabit Ethernet Switch Version 1.1 613-000368 Rev. B Copyright 2006 Allied Telesyn, Inc. All rights reserved. No part of this publication
SonicOS Enhanced 3.8.0.6 Release Notes TZ 180 Series and TZ 190 Series SonicWALL, Inc. Firmware Release: August 28, 2007
SonicOS Enhanced 3.8.0.6 TZ 180 Series and TZ 190 Series SonicWALL, Inc. Firmware Release: August 28, 2007 CONTENTS PLATFORM COMPATIBILITY SONICWALL RECOMMENDATIONS KNOWN ISSUES RESOLVED KNOWN ISSUES UPGRADING
MULTIFUNCTIONAL DIGITAL SYSTEMS. TopAccess Guide
MULTIFUNCTIONAL DIGITAL SYSTEMS TopAccess Guide 0 TOSHIBA TEC CORPORATION All rights reserved Under the copyright laws, this manual cannot be reproduced in any form without prior written permission of
V.I.P. Kit. Video Insight Pilot Kit. (Video Insight Pilot Kit).
V.I.P. Kit (Video Insight Pilot Kit). Video Insight Pilot Kit Please follow these instructions and everything should go very smoothly. Before you begin, you will need to establish (or obtain from your
Chapter 10 Troubleshooting
Chapter 10 Troubleshooting This chapter provides troubleshooting tips and information for your ProSafe Dual WAN Gigabit Firewall with SSL & IPsec VPN. After each problem description, instructions are provided
ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af
ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af 24-Port Giga PoE Current Sharing 500W PoE Budget IPv6 and IPv4 Dual Protocol SNMP v1/v2c/v3 SSH version
Management Software. User s Guide AT-S88. For the AT-FS750/24POE Fast Ethernet Smart Switch. Version 1.0. 613-000555 Rev. B
Management Software AT-S88 User s Guide For the AT-FS750/24POE Fast Ethernet Smart Switch Version 1.0 613-000555 Rev. B Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication
ProCurve Switch 1700-8 ProCurve Switch 1700-24
Management and Configuration Guide ProCurve Switch 1700-8 ProCurve Switch 1700-24 www.procurve.com ProCurve Series 1700 Switch Management and Configuration Guide Copyright 2007 Hewlett-Packard Development
Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance
CHAPTER 5 Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance This chapter describes how to configure the switch ports and VLAN interfaces of the ASA 5505 adaptive
Emerson Smart Firewall
DeltaV TM Distributed Control System Product Data Sheet Emerson Smart Firewall The Emerson Smart Firewall protects the DeltaV system with an easy to use perimeter defense solution. Purpose built for easy
FCC Certifications. CE Mark Warning
FCC Certifications This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
Firewall VPN Router. Quick Installation Guide M73-APO09-380
Firewall VPN Router Quick Installation Guide M73-APO09-380 Firewall VPN Router Overview The Firewall VPN Router provides three 10/100Mbit Ethernet network interface ports which are the Internal/LAN, External/WAN,
10/2011 - English Edition 1. Quick Start Guide. NWA1100N-CE CloudEnabled Business N Wireless Access Point
10/2011 - English Edition 1 Quick Start Guide NWA1100N-CE CloudEnabled Business N Wireless Access Point Package Contents - 1 x ZyXEL NWA1100N-CE Access Point - 2 x Detachable Antennas - 1 x Power Adapter
Coolmax CN-590 Network Storage Solution
Coolmax CN-590 Network Storage Solution Model Name Controller hip CPU OS Memory Interface CN-590 S2892 150MHz RTOS 8MB SDRAM / 1MB NOR Flash LAN Standard 10/100Base-TX Auto MDI/MDI-X Connector Type RJ-45
Gigabit Ethernet Web Smart 8-Port Switch 2 Combo SFP Open Slot
Gigabit Ethernet Web Smart 8-Port Switch 2 Combo SFP Open Slot User s Manual (DN-80201) Content Introduction ------------------------------------------------------------------------------------4 Product
N300 WiFi Range Extender
Model EX2700 User Manual July 2014 202-11395-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on
Procedure: You can find the problem sheet on Drive D: of the lab PCs. Part 1: Router & Switch
University of Jordan Faculty of Engineering & Technology Computer Engineering Department Computer Networks Laboratory 907528 Lab. 2 Network Devices & Packet Tracer Objectives 1. To become familiar with
VIP-102B IP Solutions Setup Tool Reference Manual
VIP-102B IP Solutions Setup Tool Reference Manual Table of Contents Overview... 5 System Requirements for Managed VoIP Products... 6 Term Definitions... 7 Main Application Window... 8 Legend Description...
Network Video Recorder Quick Operation Guide
Network Video Recorder Quick Operation Guide UD.6L0202B1119A01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable
TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL5428E. www.tp-link.com
TP-LINK 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch Overview TP-LINK JetStream L2 managed switch provides high performance, enterprise-level QoS, advanced security strategies and rich layer 2
Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version 3.40 12/2004
Prestige 202H Plus ISDN Internet Access Router Quick Start Guide Version 3.40 12/2004 Table of Contents 1 Introducing the Prestige...3 2 Hardware Installation...4 2.1 Rear Panel...4 2.2 The Front Panel
SHEET. Skorpion Managed Ethernet Switch Series. EISK8M Series
EISK8M Series d a t a SHEET Skorpion Managed Ethernet Switch Series The EISK8M Series offers a compact rugged managed 10/100 Mbps Ethernet switch with a choice of eight copper ports or a mix of six copper
LotWan Appliance User Guide USER GUIDE
LotWan Appliance User Guide USER GUIDE Copyright Information Copyright 2014, Beijing AppEx Networks Corporation The description, illustrations, pictures, methods and other information contain in this document
How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The
1-bay NAS User Guide INDEX Index... 1 Log in... 2 Basic - Quick Setup... 3 Wizard... 3 Add User... 6 Add Group... 7 Add Share... 9 Control Panel... 11 Control Panel - User and groups... 12 Group Management...
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005
Vantage RADIUS 50 Quick Start Guide Version 1.0 3/2005 1 Introducing Vantage RADIUS 50 The Vantage RADIUS (Remote Authentication Dial-In User Service) 50 (referred to in this guide as Vantage RADIUS)
SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3
SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,
Yamaha Audio Network Monitor User Guide
Yamaha Audio Network Monitor User Guide Note The software and this document are the exclusive copyrights of Yamaha Corporation. Copying or modifying the software or reproduction of this document, by any
D-Link Central WiFiManager Configuration Guide
Table of Contents D-Link Central WiFiManager Configuration Guide Introduction... 3 System Requirements... 3 Access Point Requirement... 3 Latest CWM Modules... 3 Scenario 1 - Basic Setup... 4 1.1. Install
4 Ports + 3 SFP Gigabit Smart Switch Use Manual. Ver.A0
4 Ports + 3 SFP Gigabit Smart Switch Use Manual Ver.A0 Chapter 1 Product Specification 1.1 Product Characteristics Complies with IEEE802.3,IEEE802.3u,IEEE802.3ab standards; 4 10/100/1000Mbps Auto-Negotiation
N300 WiFi Range Extender
Model WN3000RP User Manual September 2014 202-11409-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number
Broadband Phone Gateway BPG510 Technical Users Guide
Broadband Phone Gateway BPG510 Technical Users Guide (Firmware version 0.14.1 and later) Revision 1.0 2006, 8x8 Inc. Table of Contents About your Broadband Phone Gateway (BPG510)... 4 Opening the BPG510's
Monitoring the Switch
CHAPTER6 Any problem in your switch can affect a large proportion of your users. Implementing a preventive approach to switch monitoring helps you to detect problems early and to avoid potential problems.
Quick Start Guide. RV0xx Series Routers
Quick Start Guide RV0xx Series Routers RV042 Dual WAN VPN Router RV042G Gigabit Dual WAN VPN Router RV082 Dual WAN VPN Router RV016 Multi-WAN VPN Router Package Contents VPN Router Power Adapter (Cisco
Setting up VPN Access for Remote Diagnostics Support
Setting up VPN Access for Remote Diagnostics Support D. R. Joseph, Inc. supports both dial-up and Internet access for remote support of 3GIBC1 and LF-Sizer control systems. This document describes how
WRE2205. User s Guide. Quick Start Guide. Wireless N300 Range Extender. Default Login Details. Version 1.00 Edition 1, 06/2012
WRE2205 Wireless N300 Range Extender Version 1.00 Edition 1, 06/2012 Quick Start Guide User s Guide Default Login Details LAN IP Address http://192.168.1.2 User Name admin Passwordwww.zyxel.com 1234 Copyright
OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
OUTDOOR IR NETWORK CAMERA Series
OUTDOOR IR NETWORK CAMERA Series INSTALLATION GUIDE Please read instructions thoroughly before operation and retain it for future reference. 1. OVERVIEW 1.1 Package Content Network camera Installation
Switch Web GUI Quick Configuration Guide for
Switch Web GUI Quick Configuration Guide for SSE-G48-TG4 SSE-G24-TG4 SSE-X24S SSE-X24SR SSE-X3348S SSE-X3348SR SSE-X3348T SSE-X3348TR SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM Release: 1.0c 1
NETVIGATOR Wireless Modem Setup Guide. (TG789Pvn)
NETVIGATOR Wireless Modem Setup Guide (TG789Pvn) Configure the NETVIGATOR Wireless Modem Make sure that system meets the following requirement prior to NETVIGATOR Wireless Modem usage: - Subscribers who
User Manual Version 4.0.0.5. User Manual A20 / A50 / A100 / A250 / A500 / A1000 / A2000 / A4000
User Manual Version 4.0.0.5 User Manual A20 / A50 / A100 / A250 / A500 / A1000 / A2000 / A4000 I Endpoint Protector Appliance User Manual Table of Contents 1. Endpoint Protector Appliance Setup... 1 1.1.
Exploring the world of Canon EOS photography. EOSmagazineQ. from July-September 2009. Wireless world Communication without cables
Exploring the world of Canon EOS photography EOSmagazineQ from July-September 2009 Wireless world Communication without cables Technique Wireless Transmitters DIGITAL 00-00 Wireless world Canon s wireless
Information about IP Proprietary Telephones KX-TDA50/KX-TDA100 KX-TDA200/KX-TDA600. Hybrid IP-PBX. Model No.
Information about IP Proprietary Telephones Hybrid IP-PBX Model No. KX-TDA50/KX-TDA100 KX-TDA200/KX-TDA600 Thank you for purchasing a Panasonic Hybrid IP-PBX. Please read this manual carefully before using
NMS300 Network Management System
NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate
GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches
GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches Software Administration Manual December 2013 202-11137-04 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products.
NeoGate TG Series Installation Guide
NeoGate TG Series Installation Guide Version: V1.1 Yeastar Technology Co., Ltd. Date: Sept. 2, 2014 http://www.yeastar.com 1/14 Contents NeoGate TG Series Installation Guide 1. Preparation before Installation...
Easy Smart Configuration Utility
Easy Smart Configuration Utility REV1.1.0 1910010977 CONTENTS Chapter 1 About this Guide...1 1.1 Intended Readers... 1 1.2 Conventions... 1 1.3 Overview of This Guide... 1 Chapter 2 Getting Started...4
Cisco Small Business Smart Switches
Cisco SLM224G4S 24-Port 10/100 + 4-Port Gigabit Smart Switch: RCT Cisco Small Business Smart Switches Cost-Effective, Highly Secure Switching with Simplified Management for Growing Businesses Highlights
