Introduction. Product Research & Development
|
|
|
- Dwight Allison
- 9 years ago
- Views:
Transcription
1 Application
2 Introduction instruments and equipment gives Delta very strong design capability. Advanced engineering equipment such as Star-LT simulation software, computerized CNC machines, semi-anechoic chambers and wind tunnels are used to develop high performance, low noise and cost effective products. Manufacturing Plant 2 in Taoyuan, Taiwan Quality Assurance Delta is an ISO-9001 and TS certified manufacturer for brushless DC air cooling products. We implement strict reliability tests in the design stage and have put into place Statistical Process Controls at each production process. More than 17 years Delta has gained industry's recognition, confidence and commendation by continuously offering innovative quality brushless DC air cooling products. Broad product range covers axial fan from 25mm-200mm, blowers from 30mm-175mm, cross-flow fans and slim blowers. In combine with patented distinctive blade design, innovative structure design and "Sensflow" control not only greatly increase cooling performance but also reduce system noise with temperature sensor control when the fan is in low load operation. Fans with hot-swap construction, fan trays and modules with strong pan and first-rate efficiency are also produced. Product Research & Development Innovations are everywhere in our products. Engineering expertise backed by sophisticated test Manufacturing Delta's automation department is highly specialized in computerized state-of-the-art equipment. We build our own fully automated production lines in-house. This allows us to provide large production capacity and high quality, cost effective products to our customers. Global Operations A worldwide network of sales and technical support teams is available to our customers in Asia, USA and Europe. These teams are assisted by local designengineering centers. Delta Group is utilizing a SAP RI3 system to facilitate and optimize its linkage with customers and suppliers, allowing it to effectively monitor and maintain its world-wide logistics operations. Manufacturing Plant in Wujiang, China Manufacturing Plant in Dongguan, China Manufacturing Plant in Bangkok, Thailand
3 Evaluation Facilities ISO 3745 Anechoic Chamber Noise Chamber: Residual background noise Level : 10.0 db(a) Lowest cutoff frequency: 80 Hz Room Volume: 5.2m x 5.0m x 3.2m Instrument: HEAD acoustics System impedance noise measurement : ISO International standard Sound Power Sound Quality Sound Pressure Static Pressure Range: 0 ~ 100 & 127 mmh O 2 Air Flow Rate Range: 10 CFM, 20 CFM, 200 CFM, 250 CFM, 1000 CFM, & 3000 CFM. PL.1 PL.2 0.5J PL.7 J PL.5 PL M MIN 1.5 IN. 0.25IN SETTLING MEANS (see note 5) M VARIABLE EXHAUST SYSTEM Wind Tunnel SETTLING MEANS Waterproof fan Currently, many customer system applications in telecom and other industries are for outdoor or relatively harsh environments. Waterproof and dustproof fans are required under these conditions. In accordance with IEC60529 and the development and design for fan motor assembly protection, Delta has the capability to produce IP55 level fans. Delta production has already installed equipment to meet IEC & NEBS conditions as well as additional functional testing for other customer requirements. IPX5 IP5X
4 Telecommunication Fans Axial fan Impeller : Plastic Frame : Plastic Model Dimension Rated Voltage Operating Voltage Range Max. Speed Rated Imput Power Max. Air flow Max. Air pressure Noise Part No. L x L x T (mm) VDC VDC RPM Watt CFM IN H2O db-a AFB06X-A 60 x 60 x / to 27.6 / 28 to / AFB06XE 60 x 60 x to FFB06XE 60 x 60 x to AFB08X 80 x 80 x / to 26 / 28 to / / / / / 34.0 FFB08XE 80 x 80 x / to 26.4 / 28 to / / / / / 48.5 PFB08XE 80 x 80 x to GFB08XG 80 x 80 x to AFB09X 92 x 92 x / to 27.6 / 28 to / / / / / 38.0 FFB09X 92 x 92 x / to 27.6 / 28 to / FFB09XE 92 x 92 x / to 27.6 / 28 to / / / / / 52.5 PFB09XE 92 x 92 x / to 26.4 / 28 to / / / / / 64.0 GFB09XG 92 x 92 x / to 27.6 / 28 to / AFB12X 120 x 120 x to FFB12X 120 x 120 x / to 26.4 / 28 to / EFB12XF 120 x 120 x / 48 7 to 26.4 / 28 to AFB12XE 120 x 120 x / 48 7 to 27.6 / 28 to / / / / / 48.0 EFB12XE 120 x 120 x / 48 7 to 27.6 / 28 to / FFB12XE 120 x 120 x / to 26.4 / 28 to / TFB12XE 120 x 120 x / to 27 / 28 to / PFB12XE 120 x 120 x / to 26.5 / 30 to / GFB12XG 120 x 120 x / to 26.4 / 28 to / GFB12XW 120 x 120 x / to 26.4 / 28 to / FFB13XE 127 x 127 x / to 26.4 / 28 to / FFB14XG 140 x 140 x / to 26.4 / 28 to / The model name "X" letter means rotation speed that will be different for various models The max. air flow and the speed are measured in free air; max. air presssure is measured at zero air flow Axial fan Impeller : Plastic Frame : Metal Model Dimension Rated Voltage Operating Voltage Range Max. Speed Rated Imput Power Max. Air flow Max. Air pressure Noise Part No. L x L x T (mm) VDC VDC RPM Watt CFM IN H2O db-a FFB12XE-M 120 x 120 x / to 26.4 / 28 to / FFB14XE-M 140 x 140 x / to 26.4 / 36 to / AFB15X 172 x 150 x / to 30 / 24 to / AFB17X 172 x / to 30 / 24 to / EFB15XG 172 x 150 x / to 28 / 24 to / / / / / 60.0 EFB17XG 172 x / to 28 / 24 to / / / / / 57.0 FFB17XG 172 x to FHB12XE-M 120 x 120 x to AHB13XE 127 x 127 x to FHB14XE 140 x 140 x to AHB15X 172 x 150 x to AHB17X 172 x to AHB15XG 172 x 150 x to EHB15XG 172 x 150 x to AHB17XG 172 x to EHB17XG 172 x to FHB17XG 172 x to The model name "X" letter means rotation speed that will be different for various models The max. air flow and the speed are measured in free air; max. air press sure is measured at zero air flow Specificatons are subject to change without notice.
5 Telecommunication Blowers Open blower Impeller : : Plastic Frame : Metal Model Dimension Rated Voltage Operating Voltage Range Max. Speed Rated Imput Power Max. Air flow Max. Air pressure Noise Part No. D x T (mm) VDC VDC RPM Watt CFM IN H2O db-a KFB10XS 100 x / to 26.4 / 28 to / KFB17XS 175 x / to 30 / 28 to / KFB17XT 175 x / to 26.4 / 36 to / KFB17XT-A 175 x / to 27.6 / 28 to / KHB10XS 100 x to KHB17XS 175 x to KHB17XT 175 x to KHB17XT-A 175 x to The model name "X" letter means rotation speed that will be different for various models The max. air flow and the speed are measured in free air; max. air pres ssure is measured at zero air flow Specificatons are subject to change without notice. FREQUENCY GENERATOR O/P: (F00) Frequency generator function is activated by an internal IC for customer's application. Electrical schematic: IC R O/P Vcc. IC F.G. OUTPUT ADDITIONAL PVC WIRE CUSTOMER'S CIRCUIT Vcc = From +5 To +28 VDC (Generally using +12 or +24 VDC) Ic = 5 ma max. R = V/I (Output "R" value calculation) SUPPLY A WAVEFORM: RUNNING FOR 4 POLES BLADE LOCKED OR T1 T2 T3 T4 TS RUNNING FOR 8 POLES T1=T2=T3=T4=1/4 TS T1 T2 T3 T4 T5 T6 T7 T8 TS T1=T2=T3=T4=T5=T6=T7=T8=1/8 TS N=R.P.M. (Rotation speed will be different for various models L/M/H/HH/VH/SH) TS=60/N (Sec) * Voltage level after blade locked * 4 POLES OR 8 POLES OUTPUT LEVEL: High = Vcc 10% Low = 0~0.5V Ic = 5 ma max. APPLICATION: TIMER ENABLE F.G. C.P.U. COUNTER CALCULATOR OF SYSTEM FUNCTIONS: By means of waveform & customer's design, schematic can reach alarm function, either in the form of buzzing or LED flashing. Adjust rotation speed. When power supply output voltage level decreases, it will result in the lowering of fan rotation speed. The irregular situation will be controlled by using F.G. O/P through P/S circuit to increase the output voltage and result in a stable rotation speed. ROTATION DETECTOR O/P (R00) Rotation detector function is activated by an internal IC for customer's application. Electrical schematic: IC R O/P Vcc. IC R.D. ADDITIONAL PVC WIRE CUSTOMER'S CIRCUIT BLADE LOCKED CUSTOMER'S CIRCUIT CUSTOMER'S CIRCUIT Vcc = From +5 To +28 VDC (Generally use +12 or +24 VDC) Ic = 5 ma max. R = V/I (Output "R" value calculation) OR SUPPLY A WAVEFORM: RUNNING OUTPUT LEVEL: High = Vcc 10% Low = 0~0.5V Ic = 5 ma max. APPLICATION: R.D. BLADE LOCKED I R ALARM/BUZZER FUNCTION: By means of waveform & customer's design, schematic can reach alarm function: either in the form of buzzing or LED flashing. TEMPERATURE CONTROL : "SENSFLOW" With temperature controlled fan, the RPM can be controlled by on board or off board thermistor. The RPM and temperature range is subject to custom request. Rth (Thermistor) Thermal control Speed (RPM) Voltoge Resistonce Speed (RPM) PWM CONTROL In PWM speed control, a fixed frequency square wave is applied to the speed control lead wire of the fan. The ratio of the on time vs. the PWM period is proportional to the RPM. PWM control t T PWM Signal Input _t Duty Cycle= T Customer Circuit PWM control Signal Output T1 Speed PWM INPUT VOLTAGE RANGE: High level= 2.8 to 20 VDC Low level= 0 to 0.4 VDC PWM INPUT CURRENT (IPWM) RANGE: 40uA to 20mA T2 Vth Rth o Temperature (C) o Temperature (C) o Temperature (C) To control signal line of the fan shall be able to accept a 30Hz to 30kHz. The preferred operating point for the fan is 0%~100% of duty cycle. Duty Cycle Speed % Duty Cycle
6 Delta STD 6 Fan tray Character: Fan Trays Model Rated Voltage Operating Temperature Speed Input Current Input Power Maximum Air Flow Maximum Air Pressure Noise Part No. VDC RPM Amp Watt CFM IN H2O db-a Delta STD 6 fan tray ~ The max. air flow and the speed are measured in free air; max. air press sure is measured at zero air flow Fan Type: 6pcs axial fan Communication: I^C Advantage: Soft Start, Over Voltage Protection,Over Current Protection, Fan Speed or Temperature Detect,PWM or Voltage Speed Control, Linear Speed Change, Hot Swappable Function, Thermal Fail or Over Temperature Alarm Signal Output,Redundancy Function,Reverse Polarity Protection,Inrush Current Protection,EEPROM,EMC Delta STD 9 Fan tray Character: Model Rated Voltage Operating Temperature Speed Input Current Input Power Maximum Air Flow Maximum Air Pressure Noise Part No. VDC RPM Amp Watt CFM IN H2O db-a Delta STD 9 fan tray ~ The max. air flow and the speed are measured in free air; max. air presssure is measured at zero air flow Fan Type: 9 pcs axial fan Communication: I^C Advantage: Soft Start, Over Voltage Protection,Over Current Protection, Fan Speed or Temperature Detect,PWM or Voltage Speed Control, Linear Speed Change, Hot Swappable Function, Thermal Fail or Over Temperature Alarm Signal Output,Redundancy Function,Reverse Polarity Protection,Inrush Current Protection,EEPROM,EMC Delta Fan Tray Capability: Wide Input Voltage Range:10VDC~75VDC Widely Applicative Fan: 12V/24V/48VDC Optimal cooling design of heat dissipation Flexible Manufacture 100% Auto Function Testing 100% Burn In Testing & Monitor Equipment Industry & Telecom (Indoor & outdoor) & Networking and other application ODM & OEM Design Communication: I^C,RS232, RS485 DC/DC Converter Safety Compliance: UL/CUL/TUV/VDE/CE Specificatons are subject to change without notice.
7 AdvancedTCA AdvancedTCA Fan & Blower Available Air outlet Front Board 14 RTM Air inlet 3D View ATCA 13U (14 Slot) System Controller Boards Delta's fan controllers are designed for the telecom industry. This system cooling solution provides an interface with fan speed control. Features Wide Input Range: 10VDC ~ 75VDC Widely Applicative Fan: 12V/24V/48VDC Soft Start Function at Start Up Reverse Polarity Protection Hot-Swap Inrush Current Protection Function Fail Alarm Indication Redundancy Function Over Voltage and Over Current Protection Thermal Detect and Fan Speed Control PWM or Voltage Control Speed Communication Function: I2C, RS232...etc Custom Design is Accepted Control Functions Fan Speed Alarm Settings Fan Fail Alarm Multiple Fans Fail Alarm Over Temperature or Thermal Fail Alarm Warning for Insufficient Input Power. RPM VS Temperature: Two Modes of Speed Control are Applied. Linear Mode. Step Mode. Fan Tray Production Auto Test Equipment Delta Fan Tray Burn In Monitor System First Layer Temperature( C) Fan 1 Fan 2 Fan 3 Fan 4 Fan 13 Fan 14 Fan 5 Fan 6 Fan 7 Fan 8 Fan 9 Fan 10 Fan 15 Fan 16 Fan 17 Fan 20 Fan 5 Fan 6 Fan 7 Fan 8 Fan 9 Fan 10 Fan 15 Fan 16 Fan 17 Fan 20 Fan 5 Fan 6 Fan 7 Fan 8 Fan 9 Fan 10 Fan 15 Fan 16 Fan 17 Fan 20 Current Test Model Name Signal Type Operation Voltage Fan 11 Fan 12 On /Off Cycle Time Middle Layer Temperature( C) Fan 1 Fan 2 Fan 11 Fan 12 Signal Voltage Fan 3 Fan 4 Fan 13 Fan 14 Accumulate Time Operating Operating Status Records Bottom Layer Temperature( C) Fan 1 Fan 2 Fan 3 Fan 4 Fan 13 Fan 14 Initial Statusds Fan 11 Fan 12 Start Normal Status Signal 1 output Signal 2 output Reset Burn In Monitor Equipment Specificatons are subject to change without notice. Exit Auto Test Machine: Function, Waveform, Inrush Current, LED, Fan Speed Detector, Others
8 w ww.deltaww.com DELTA ELECTRONICS, INC. 186 RUEY KUANG ROAD, NEIHU, TAIPEI TAIWAN, REPUBLIC OF CHINA TEL : FAX : DELTA ELECTRONICS (DONGGUAN) CO., LTD. DELTA INDUSTRIAL ESTATE, SHIJIE TOWN, DONGGUAN, GUANGDONG, PEOPLE'S REPUBLIC OF CHINA POST CODE : TEL : FAX : DELTA ELECTRONICS COMPONENTS (WU JIANG) LTD JIANGXING EAST ROAD, WUJIANG ECONOMIC DEVELOPMENT ZONE, WUJIANG CITY,JIANG SU PROVINCE, PEOPLE'S REPUBLIC OF CHINA POST CODE : TEL : FAX : DELTA ELECTRONICS (JAPAN), INC. DELTA SHIBADAIMON BUILDING, SHIBADAIMON, MINATO-KU, TOKYO, JAPAN TEL : FAX : DELTA ELECTRONICS (SINGAPORE) PTE. LTD. 8 KAKI BUKIT ROAD 2, #04-18 RUBY WAREHOUSE COMPLEX, SINGAPORE TEL : FAX : DELTA PRODUCTS CORPORATION FREMONT OFFICE 4405 CUSHING PARKWAY, FREMONT, CA 94538, TEL : FAX : PORTLAND OFFICE SW KOLL PARKWAY, SUITE K, BEAVERTON, OR 97006, TEL : FAX : LOS ANGELES OFFICE 927 CANADA COURT, CITY OF INDUSTRY, CA 91748, TEL : FAX : HOUSTON OFFICE 8270 WILLOW PLACE NORTH, SUITE 150, HOUSTON, TX 77070, TEL : FAX : SAN DIEGO OFFICE VIA DEL CAMPO #303, SAN DIEGO, CA 92127, TEL : FAX : RALEIGH OFFICE P.O. BOX 12173, 5101 DAVIS DRIVE, RESEARCH TRIANGLE PARK, NC TEL : FAX : BOSTON OFFICE 175 CABOT STREET, SUITE #310, LOWELL, MA 01854, TEL : FAX : AUSTIN OFFICE 575 ROUND ROCK WEST DRIVE, BUILDING K, SUITE#440, ROUNDROCK,TX 78681, TEL : FAX : DAKOTA OFFICE 3500 SOUTH LAKEPORT STREET, #H, SIOUX CITY, IA 51106, TEL : FAX : DETROIT OFFICE SCHOOLCRAFT ROAD, SUITE B-9, LIVONIA, MI 48150, TEL : FAX : DELTA ELECTRONICS (EUROPE), LTD. AMSTERDAM OFFICE WEGALAAN 16, 2132 JC HOOFDDORP, THE NETHERLANDS TEL : FAX : EINDHOVEN OFFICE DE WITBOGT 15, 5652 AG EINDHOVEN, THE NETHERLANDS TEL : FAX: GLASGOW OFFICE 1 REDWOOD COURT, PEEL PARK, EAST KILBRIDE, G74 5PF, SCOTLAND, UNITED KINGDOM TEL : FAX : SOEST OFFICE COESTERWEG 45, D-59494, SOEST GERMANY TEL : 49 (0) FAX : 49 (0) DELTA ELECTRONICS (THAILAND) PUBLIC COMPANY LIMITED 111 MOO 9, WELLGROW INDUSTRIAL ESTATE, BANGNA-TRAD ROAD., TAMBON BANGWUA', AMPHUR BANGPAKONG, CHACHOENGSAO 24180, THAILAND TEL : FAX :
Introduction. Internet:http://www.deltaww.com
Introduction More than 18 years Delta has gained industry's recognition, confidence and commendation by continuously offering innovative quality brushless DC air cooling products. Broad product range covers
SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2
SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 APPROVED NO : APPROVED BY : (AUTHORIZED) SPEC.NO D600023 ISSUE DATE 08.06.1998 DAWN.
SUNON SPECIFICATION FOR APPROVAL
SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X25 mm M O D E L : KDE2406PTB2 APPROVED NO : APPROVED BY : (AUTHORZIED) SPEC.NO D600732 ISSUE DATE 10.01.1998 DAWN.
+ A + + - B V B - - + + + NO NC V COM - - - PV PV
+ - A + B B - V + - NO NC COM + - + - V + - PV PV Ramp Soak 100 70 50 30 3 5 3 8 5 3 Minute Steam Heating Sensor Cooling Water PID Hotplate Specifications Input power supply AC 100 to 240V, 50/60Hz, DC
RELAYS Solar Energy Systems
RELAYS Solar Energy Systems FUJITSU COMPONENTS CONTENTS Fujitsu relays for solar applications DC voltage versions - AC voltage versions - Latching versions RELAY PRODUCT LINE UP - SOLAR ENERGY SYSTEMS
Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.
COOLING FAN REQUIREMENTS CALCULATIONS Determining System Impedance Determining the actual airflow produced by a fan mounted in an enclosure is much more difficult than calculating the airflow required.
Solar Inverters. Ferrites in Renewable Energies: Solar Inverters. customer requirements. Support and flexibility to design custom product to fulfill
Support and flexibility to design custom product to fulfill customer requirements Optimum ferrite material selection for magnetic applications in the design for cost saving, and performance improvement
Miniatur Radial Gebläse mit integrierter Elektronik Miniature Radial Blower with integrated electronic
Baureihen / Series U51DL-012KK-4 Miniatur Radial Gebläse mit integrierter Elektronik Miniature Radial Blower with integrated electronic Technische Daten Allgemeine Beschreibung Kompakter Lüfter mit effizientem
MAXIMUM LOAD CURRENT 1 A SN SERIES
SOLID STATE RELAY (I/O Module) MAXIMUM LOAD CURRENT 1 A SN SERIES RoHS compliant FEATURES I/O modules for interface between CPU and external input devices or loads Ultra slim and light weight, SIL s type
MAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
I STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)
CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR) Fig1. CPTR SMART CONTROL PRECISION CUSTOMIZED MANUAL OR AUTO SCR OR DIODE DRY TYPE SWITCH MODE DRY TYPE SCR OR DIODE OIL TYPE 1 INDEX PAGE 1. Cover 2. Index
Data Center Cooling. The engineer s choice
Data Center Cooling The engineer s choice About ebm-papst Inc. Headquarters - Farmington, CT» 250K sq. ft.» Acoustic testing chamber» Complete air testing lab on site» Mechanical/Design Engineering» Electrical
Energy Saving ECM Motors and Fans. 2010 Ventilation Catalogue
Energy Saving ECM s and Fans 2010 Ventilation Catalogue CONTENTS For ellington, sustainability is about delivering products at competitive prices while preserving the environment for future generations.
30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
Series AMLDL-Z Up to 1000mA LED Driver
FEATURES: Click on Series name for product info on aimtec.com Series Up to ma LED Driver Models Single output Model Input Voltage (V) Step Down DC/DC LED driver Operating Temperature range 4ºC to 85ºC
1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES
POWER RELAY 1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES RoHS compliant FEATURES Ultra slim type with 5 mm thickness Good for high density mounting Low power consumption and high sensitivity Nominal
NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES
FTR-K1 SERIES MINIATURE RELAY 2 POLES - 1 to 2 A (For Signal Switching) NA Series FEATURES Slim type relay for high density mounting Conforms to Telcordia specification and FCC Part 68 - Dielectric strength
High Power LED Driver Series User s Guide
High Power LED Driver Series User s Guide 2004-2010 Sure Electronics Inc. LE-LL15113-LE-LL14113_Ver1.0 Table of Contents Chapter 1. Overview...1 1.1 Overview... 1 1.2 Features... 2 1.3 Applications...
ebm-papst North America
ebm-papst North America Data Center Cooling The engineer s choice About ebm-papst Inc. Headquarters - Farmington, CT» 250K sq. ft.» Acoustic testing chamber» Complete air testing lab on site» Mechanical/Design
SWITCH-MODE POWER SUPPLY CONTROLLER PULSE OUTPUT DC OUTPUT GROUND EXTERNAL FUNCTION SIMULATION ZERO CROSSING INPUT CONTROL EXTERNAL FUNCTION
SWITCH-MODE POWER SUPPLY CONTROLLER. LOW START-UP CURRENT. DIRECT CONTROL OF SWITCHING TRAN- SISTOR. COLLECTOR CURRENT PROPORTIONAL TO BASE-CURRENT INPUT REERSE-GOING LINEAR OERLOAD CHARACTERISTIC CURE
MINIATURE SURFACE MOUNT RELAY
FTR-K1 SERIES MINIATURE SURFACE MOUNT RELAY 1 POLE - 25A (For Automotive Applications) FTR-P6 Series FEATURES Surface mount relays for automotive applications Miniature size (67% of the volume of FTR-P3
COMPACT POWER TWIN RELAY
FTR-K1 SERIES COMPACT POWER TWIN RELAY 1 POLE x 2-25A, H-Bridge (for automotive applications) FTR-P4 Series FEATURES Compact for high density packaging High contact capacity with proven contact material
LM78XX Series Voltage Regulators
LM78XX Series Voltage Regulators General Description Connection Diagrams The LM78XX series of three terminal regulators is available with several fixed output voltages making them useful in a wide range
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
TDA2822 DUAL POWER AMPLIFIER SUPPLY VOLTAGE DOWN TO 3 V LOW CROSSOVER DISTORSION LOW QUIESCENT CURRENT BRIDGE OR STEREO CONFIGURATION
TDA2822 DUAL POER AMPLIFIER SUPPLY VOLTAGE DON TO 3 V. LO CROSSOVER DISTORSION LO QUIESCENT CURRENT BRIDGE OR STEREO CONFIGURATION DESCRIPTION The TDA2822 is a monolithic integrated circuit in 12+2+2 powerdip,
7-41 POWER FACTOR CORRECTION
POWER FTOR CORRECTION INTRODUCTION Modern electronic equipment can create noise that will cause problems with other equipment on the same supply system. To reduce system disturbances it is therefore essential
POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES
POWER RELAY POLE - 6A / Inrush 20A relay FTR-K-KS Series FTR-K SERIES FEATURES pole 6A, form A or form C Peak inrush current 20A / TV-8 Coil power 400mW High insulation in small package (between coil and
1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C
FTR-K1 SERIES POWER RELAY 1 POLE - 16A / Inrush 120A relay FTR-K1-KS Series FEATURES 1 pole 16A, 1 form A or 1 form C Peak inrush current 120A / TV-8 Coil power 400mW High insulation in small package (between
Galleon 6-10K Online UPS. Voltronic Power Technology Corporation
Galleon 6-10K Online UPS Voltronic Power Technology Corporation Features Galleon online UPS series delivers optimal power quality, provides superior power management, resolves utility power protection
DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES
MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) FBR46 SERIES RoHS compliant FEATURES Miniature size About 50% smaller in volume compared with the FBR240 series used mainly in communication equipment.
2 X 250Watt Class D Audio Amplifier Board IRS2092 User s Guide
2 X 250Watt Class D Audio Amplifier Board IRS2092 User s Guide 2004-2013 Sure Electronics Inc. AA-AB32291_Ver1.0 2 X 250Watt Class D Audio Amplifier Board IR2092 Note: Please read this manual carefully
D.C. Motors. Products and specifications subject to change without notice.
D.C. Motors Order/Technical Support - Tel: (8) 677-5 / FAX: (8) 677-865 / www.crouzet-usa.com / DC Motors Selection guide Gearbox Speed Torque max (Nm).5. Type of Gearbox 8 8 8. Power usable (w) Torque
SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES
FTR-K1 SERIES SILENT POWER RELAY 1 POLE - 78A/120A Inrush Current Type FTR-H3 Series FEATURES Pin compatible with widely used VS and FTR-H1 series power relays Silent relay with patented unique U-shape
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
AN2680 Application note
Application note Fan speed controller based on STDS75 or STLM75 digital temperature sensor and ST72651AR6 MCU Introduction This application note describes the method of defining the system for regulating
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
LM566C Voltage Controlled Oscillator
LM566C Voltage Controlled Oscillator General Description The LM566CN is a general purpose voltage controlled oscillator which may be used to generate square and triangular waves the frequency of which
1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) HIGH INSULATION Insulation distance (between coil and
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
Amphenol LTW Technology Co., Ltd. Amphenol LED Market. http://www.amphenolltw.com. Innovation in Waterproof Solution
Amphenol LTW Technology Co., Ltd. Amphenol LED Market http://www.amphenolltw.com Innovation in Waterproof Solution Amphenol LTW Our History LTW Technology, established in 1993, is a professional designer
EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.
EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. A Regal Brand EVERGREEN SOLUTIONS Powered by ECM Technology Upgrade/Replace PSC motors with Evergreen IM Residential/Light Commercial HVAC Systems Reduce
Antec TruePower User's Manual
User s Manual Antec TruePower User's Manual Antec TruePower ATX12V power supply Models: TRUE330, TRUE380, TRUE430, TRUE480, TRUE550 Antec Low Noise Technology: The Antec TruePower power supply is equipped
PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP
PowerAmp Design COMPACT HIGH VOLTAGE OP AMP Rev G KEY FEATURES LOW COST SMALL SIZE 40mm SQUARE HIGH VOLTAGE 200 VOLTS HIGH OUTPUT CURRENT 10A PEAK 40 WATT DISSIPATION CAPABILITY 200V/µS SLEW RATE APPLICATIONS
FACTORY AUTOMATION INTELLIGENT CLAMP MONITORING FOR MACHINE TOOL SPINDLES WITH INDUCTIVE POSITIONING SYSTEMS
FACTORY AUTOMATION INTELLIGENT CLAMP MONITORING FOR MACHINE TOOL SPINDLES WITH INDUCTIVE POSITIONING SYSTEMS POSITION DETECTION FOR MACHINE TOOL CLAMP OPTIMIZING THE TOOL CLAMPING PROCESS The core of a
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
Process Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.
LM 358 Op Amp S k i l l L e v e l : I n t e r m e d i a t e OVERVIEW The LM 358 is a duel single supply operational amplifier. As it is a single supply it eliminates the need for a duel power supply, thus
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
Audible Alarm Basics Everything you wanted to know, but were afraid to ask by Dan O Brien, Sales Engineer, Mallory Sonalert Products, Inc.
Audible Alarm Basics Everything you wanted to know, but were afraid to ask by Dan O Brien, Sales Engineer, Mallory Sonalert Products, Inc. From smoke detectors to automobiles, audible alarms (also known
CLASS-D VERTICAL DEFLECTION AMPLIFIER FOR TV AND MONITOR APPLICATION OUT CFLY + CFLY - BOOT VREG FEEDCAP FREQ. July 2001 1/8
CLASS-D VERTICAL DEFLECTION AMPLIFIER FOR TV AND MONITOR APPLICATION FEATURES PRELIMINARY DATA HIGH EFFICIENCY POWER AMPLIFIER NO HEATSINK SPLIT SUPPLY INTERNAL FLYBACK GENERATOR OUTPUT CURRENT UP TO.5
L78M00 SERIES POSITIVE VOLTAGE REGULATORS. www.tvsat.com.pl
SERIES POSITIVE VOLTAGE REGULATORS OUTPUT CURRENT TO 0.5A OUTPUT VOLTAGES OF 5; 6; 8; 9; 10; 12; 15; 18; 20; 24V THERMAL OVERLOAD PROTECTION SHORT CIRCUIT PROTECTION OUTPUT TRANSISTOR SOA PROTECTION DESCRIPTION
Talon and Talon SR User Manual
Talon and Talon SR User Manual Brushed DC motor controller Version 1.3 Cross the Road Electronics, LLC www.crosstheroadelectronics.com Cross The Road Electronics, LLC Page 1 4/2/2013 Device Overview Clear,
EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE
EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE Vivek Khaire, Dr. Avijit Goswami Applied Thermal Technologies India 3rd Floor,C-Wing,Kapil Towers, Dr. Ambedkar Road, Pune- 411 1 Maharashtra,
2 POLES 1 to 2 A (FOR SIGNAL SWITCHING)
MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RY SERIES FEATURES Ultra high sensitivity UL, CSA recognized Conforms to FCC rules and regulations Part 68 Surge strength 1,500 V High dielectric
Photovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
Fan Basics and Selection Criteria (How to Use)
Feature: Understanding SANYO DENKI Products from Scratch Fan Basics and Selection Criteria (How to Use) Honami Osawa 1. Introduction In recent years, the importance of cooling technology has become even
Surface Technology. Centrifugal Fan GMD
Centrifugal Fan ATEX classed adapted for paint shops Wide assortment broad area of application Service friendly low maintenance costs Headquarters: Centrifugal Fan Centrifugal Fan is a direct driven industrial
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
SX460. Generator Automatic Voltage Regulator Operation Manual
SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.
LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description
Three terminal adjustable current sources Features Operates from 1V to 40V 0.02%/V current regulation Programmable from 1µA to 10mA ±3% initial accuracy Description The LM134/LM234/LM334 are 3-terminal
LM1596 LM1496 Balanced Modulator-Demodulator
LM1596 LM1496 Balanced Modulator-Demodulator General Description The LM1596 LM1496 are doubled balanced modulator-demodulators which produce an output voltage proportional to the product of an input (signal)
User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual
ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) User Manual Table of Contents 1 Introduction 2 General specification 3 Installation 4 Pin assignment & function of connectors 5 Drawing
Features. Dimensions
Description With an IDE interface and strong data retention ability, 40-Pin IDE Flash Modules are ideal for use in the harsh environments where Industrial PCs, Set-Top Boxes, etc. are used. Placement Features
Frequency Converter Fv
2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)
Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.
Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections
A SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant
MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) A SERIES RoHS compliant FEATURES Extremely low profile and light weight Height: 5 mm Weight: approximately 1.2 g Meet FCC (Part 68) standard Conforms
2SK1056, 2SK1057, 2SK1058
SK6, SK7, SK8 Silicon N-Channel MOS FET Application Low frequency power amplifier Complementary pair with SJ160, SJ161 and SJ16 Features Good frequency characteristic High speed switching Wide area of
Specifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
WHITE LED STEP-UP CONVERTER. Features
General Description The is an inductor-based DC/DC converter designed to drive up to eight white LEDs in series for backlight. Only one feedback resistor is needed to control the LED current and obtain
LM134-LM234 LM334 THREE TERMINAL ADJUSTABLE CURRENT SOURCES. OPERATES from 1V to 40V
LM134-LM234 LM334 THREE TERMINAL USTABLE CURRENT SOURCES OPERATES from 1 to 40. 0.02% CURRENT REGULATION PROGRAMMABLE from 1µA to 10mA ±3% INITIAL ACCURACY DESCRIPTION The LM134/LM234/LM334 are 3-terminal
The quadrature signals and the index pulse are accessed through five 0.025 inch square pins located on 0.1 inch centers.
Quick Assembly Two and Three Channel Optical Encoders Technical Data HEDM-550x/560x HEDS-550x/554x HEDS-560x/564x Features Two Channel Quadrature Output with Optional Index Pulse Quick and Easy Assembly
SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)
OBSOLETE NMPD0 Series SELECTION GUIDE Order Code Nominal Input Voltage Output Voltage Efficiency (Min.) Power (Max.) V V % W NMPD003C 3. 9.50 NMPD005C 5. 9.5 NMPD0C. 0 0.00 NMPD05C 5. 9 0.00 FEATURES RoHS
SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial
SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial MODEL NUMBER: SMART1500SLT Highlights 1.5kVA / 1500VA line interactive tower UPS; Sine wave output
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
HCF4056B BCD TO 7 SEGMENT DECODER /DRIVER WITH STROBED LATCH FUNCTION
BCD TO 7 SEGMENT DECODER /DRIVER WITH STROBED LATCH FUNCTION QUIESCENT CURRENT SPECIF. UP TO 20V OPERATION OF LIQUID CRYSTALS WITH CMOS CIRCUITS PROVIDES ULTRA LOW POWER DISPLAY. EQUIVALENT AC OUTPUT DRIVE
Agilent 4338B Milliohm Meter
Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top
SD Series. SD Series Rectifiers. EPC Energy & Power Conversion
Rectifiers Microprocessor controlled rectifier technology Fully adjustable float, boost and equalizing charge modes with V/I characteristic Advanced technology for phase control Verylowvoltage ripple and
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
Description. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
1 POLE - 5A SLIM POWER RELAY
POWER RELAY POLE - A SLIM POWER RELAY FTR-MY Series RoHS compliant FEATURES Width mm, height mm,(% smaller than NY series) area mm, super slim, low power, compact and light weight.gr. Nominal power: mw
Features. Symbol JEDEC TO-220AB
Data Sheet June 1999 File Number 2253.2 3A, 5V,.4 Ohm, N-Channel Power MOSFET This is an N-Channel enhancement mode silicon gate power field effect transistor designed for applications such as switching
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
Speed Control Relays SX2
SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................
STGW40NC60V N-CHANNEL 50A - 600V - TO-247 Very Fast PowerMESH IGBT
N-CHANNEL 50A - 600V - TO-247 Very Fast PowerMESH IGBT Table 1: General Features STGW40NC60V 600 V < 2.5 V 50 A HIGH CURRENT CAPABILITY HIGH FREQUENCY OPERATION UP TO 50 KHz LOSSES INCLUDE DIODE RECOVERY
HCC4541B HCF4541B PROGRAMMABLE TIMER
HCC4541B HCF4541B PROGRAMMABLE TIMER 16 STAGE BINARI COUNTER LOW SYMMETRICAL OUTPUT RESISTANCE, TYPICALLY 100 OHM AT DD = 15 OSCILLATOR FREQUENCY RANGE : DC TO 100kHz AUTO OR MASTER RESET DISABLES OSCIL-
Features. Dimensions
Description With an IDE interface and strong data retention ability, 40-Pin IDE Flash Modules are ideal for use in the harsh environments where Industrial PCs, Set-Top Boxes, etc. are used. Placement Features
PM734F - Technical Data Sheet Winding 28
- Technical Data Sheet Winding 28 SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including
*.ppt 11/2/2009 12:48 PM 1
Digital Compressor Controller *.ppt 11/2/2009 12:48 PM 1 Copeland Scroll Digital Controller Simple Controller That Enables OEM s To Use Digital Scrolls Relieves OEM From Developing Special Controllers
MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET
FOR IMMEDIATE RELEASE No. 2387 Product & Catalogue Inquiries: Media Contact Naoto Shimada Travis Woodward Nakatsugawa Works Public Relations Department Photovoltaic Power System Business Center Mitsubishi
1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) High insulation Insulation distance (between coil and
Agilent AEDB-9140 Series Three Channel Optical Incremental Encoder Modules with Codewheel, 100 CPR to 500 CPR Data Sheet
Agilent AEDB-9140 Series Three Channel Optical Incremental Encoder Modules with Codewheel, 100 CPR to 500 CPR Data Sheet Description The AEDB-9140 series are three channel optical incremental encoder modules
LM337. Three-terminal adjustable negative voltage regulators. Features. Description
Three-terminal adjustable negative voltage regulators Datasheet - production data current limit, thermal overload protection and safe area protection. All overload protection circuitry remains fully functional
Micro cogeneration. Affordable, efficient and innovative
Micro cogeneration Affordable, efficient and innovative A compact and efficient solution A compact and efficient solution Organisations are increasingly looking for environmentally friendly systems to
Silvertel. Ag5200. 1 Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power
Silvertel V1.1 November 2012 Datasheet Pb 1 Features IEEE802.3at and IEEE802.3af compliant Maximum 30W output power Dual In-Line (DIL) package size 50.6mm (L) x 30mm (W) Overload, short-circuit and thermal
HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies
25.2W/in 3 power density Internal ORing MOSFET & Current Share Climate Savers Computing efficiency standards Up to 8000W in 1U rack Single and dual output 1U racks PMBus option HFE1600 Series 1600W 1U