Steel radiators Quality assessment RAL-GZ 618
|
|
|
- Grace Lee
- 9 years ago
- Views:
Transcription
1 Steel radiators Quality assessment RAL-GZ 618 June 2007 edition DEUTSCHES INSTITUT FÜR GÜTESICHERUNG UND KENNZEICHNUNG E.V.
2 Published by RAL Deutsches Institut für Gütesicherung und Kennzeichnung e.v. ( German quality assessment and labelling institute ) Sieburger Strasse Sankt Augustin (Germany) Tel. +49 (0) Fax +49 (0) [email protected] Internet: No reprinting allowed of the document or of any extracts RAL also reserves the right to translation into other languages. 2007, RAL, Sankt Augustin Available from: Beuth-Verlag GmbH, Burggrafenstrasse 6, Berlin (Germany) Tel. +49 (0) , Fax +49 (0) , [email protected], Internet: Page
3 Steel radiators Quality assessment RAL-GZ 618 Gütegemeinschaft Heizkörper aus Stahl e.v. Frankfurter Strasse Cologne (Germany) Tel. +49 (0) Fax +49 (0) Internet: These quality and inspection regulations have been prepared jointly by RAL Deutsches Institut für Gütesicherung und Kennzeichnung e.v., (the German quality assessment and labelling institute), under the principles for quality labels in acceptance proceedings with the collaboration of the Federal Ministry of the Economy and Technology and with the assistance of technical and commercial experts and the competent authorities. The quality and inspection regulations were revised in April Sankt Augustin, June 2007 RAL Deutsches Institut für Gütesicherung und Kennzeichnung e.v price group 10 Page 2
4 Contents Quality and inspection regulations for steel radiators Page 1 Scope of validity Field of application Normative references 5 2 Quality and inspection regulations Conformity to Standards Procedure for substantiating conformity to Standards Test laboratories Test request and sampling Submission of proof of conformity Scope of tests to substantiate conformity to Standards Model testing Model series testing Model family testing Special criteria for the selection of the models for testing Types of tests for proof of conformity to Standards Initial test for proof of conformity to Standards Secondary test Follow-up test for conformity with Standards Check test Supplementary test Materials Dimensions and limits Processing Base material Joining process Working pressures and pressure tests Coating Priming coat Finishing coat Data in printed matter 8 3 Monitoring Initial inspection Substantiation of conformity to Standards Adherence to quality and inspection regulations Substantiation of a reliable internal inspection system Internal inspection External Inspection Substantiation of conformity to Standards Testing of labelling Adherence to these quality and test regulations Substantiation of a reliable internal monitoring system Monitoring changes Rectification of defects Test report Testing costs 9 4 Changes to certified radiators 9 5 Labelling 10 6 Amendments 10 Page 3
5 Appendices to the Quality and Inspection Regulation Appendix A Special requirements for specific radiator models 11 Appendix A 1: Quality requirements for panel radiators 12 Appendix A 2: Quality requirements for tubular steel sectional radiators 15 Appendix A 3: Quality requirements for heating walls and convectors 18 Appendix A 4: Quality requirements for bathroom and designer radiators 22 Appendix A 5: Quality requirements for steel element radiators 25 Appendix A 6: Quality requirements for ribbed tube convectors 28 Appendix B: Selection of models for testing from model series and families 31 Appendix B 1: Model triangle : Selection of models for testing 31 Appendix B 2.1: Model family in the broader sense: Typical example 33 Appendix B 2.2: Model family in the broader sense: Selection of models for testing 34 Appendix B 3.1: Model family in the narrower sense: Typical example 35 Appendix B 3.2: Model family in the narrower sense: Selection of models for testing 36 Appendix C: Data sheet for steel radiator 37 Appendix D: Confirmation that the appendix to the obligation note is up to date 38 Executive Regulations for the awarding and holding of the quality label for steel radiators 1 Quality basis 39 2 Award 39 3 Use 39 4 Monitoring 39 5 Penalties for violations 40 6 Appeals 40 7 Re-awards 41 8 Changes 41 Sample 1 to the executive regulations 42 Sample 2 to the executive regulations 44 Page 4
6 Quality and inspection regulations for steel radiators 1 Scope of validity 1.1 Field of application These quality regulations apply to steel radiators for use in heating systems the task of which consists of transferring the heat provided by the heating water by convection and radiation. This includes all radiators and convectors designed for installation in central heating systems in buildings and for operating with water or steam at temperatures below 120 C and are supplied from a separate heat source. Coatings for radiators intended for rooms with a corrosive and/or damp atmosphere are not a subject of the quality and inspection regulations. Such rooms also include bathrooms and toilets in which moisture frequently forms due to projection, e.g. in public or sports facilities. Kitchens in addition to areas outside the projection range of showers and toilets or similar installations in bathrooms of living areas etc. are not to be regarded as rooms with a corrosive and/or damp atmosphere in this case. These quality and inspection regulations define quality requirements for the steel radiator as a product and for its monitoring. These quality and inspection regulations also define the requirements for the quality assurance system of the user of the quality label so that substantiation can be provided that the products have been manufactured and supplied in accordance with these guidelines. 1.2 Normative references These quality and inspection regulations refer to and thus contain regulations under various Industrial Standards. The references are quoted at the relevant points and the publications are listed at the end. The most recently revised version applies in each case. DIN EN Radiators and convectors Part 1: Technical specifications and requirements DIN EN Radiators and convectors Part 2: Test methods and rating DIN EN Radiators and convectors Part 3: Evaluation of conformity DIN EN Cold-rolled uncoated low carbon and highyield strength steel flats for cold forming; tolerances on size and geometrical tolerances DIN EN Metallic products - Types of inspection documents DIN EN ISO 2409 EN ISO 9001 ISO DIN DIN Paints and varnishes - Cross-cut test Quality management systems - Requirements General tolerances; tolerances for l for linear and angular dimensions without individual tolerance indications Coatings for radiators - Part 1: Terms, requirements and tests for primers and industrially applied priming coats. Coatings for radiators - Part 2: Terms, requirements and tests for finishing paints and industrially applied finishing coats. 2 Quality and inspection regulations The basis for awarding the quality label is proof of marketability (CE labelling) of the steel radiators based on EN to EN Details of this conformity procedure are described by the Quality Association for Steel Radiators in section 2.1 et seq. Associated with this is also proof of compliance with the accompanying standards according to section 1.2 in the sections which refer to the scope of validity of these quality and inspection regulations. Furthermore, the quality requirements defined by the quality association for steel radiators according to appendices A and B which go over and beyond the pertinent standards must comply with by the applicant/licensee. 2.1 Conformity to Standards One indispensable requirement for granting the quality label is proof that the radiator conforms to Standards EN to EN Procedure for substantiating conformity to Standards Test laboratories The test described below have to be carried out on a reference test bench (EN sub-section 6.2.2) or on a recognised test bench (EN sub-section ). The test benches have to be accepted by the Executive Committee of RAL-Gütegemeinschaft Heizkörper aus Stahl (hereinafter called the Association for short) Test request and sampling The applicant will request the first test for conformity to the Standards without any set formalities from a testing laboratory in accordance with sub-section above. The customer will deliver the number of radiators necessary according to EN sub-section 5.2 and/or agreed between him and the testing laboratory together with the test request. The customer will make no charge for delivering the radiators or for collecting them afterwards. The manufacturer will select and deliver the first samples for testing for conformity to the Standards. Samples for all later tests under the provisions of subsection will be taken from on-going production or from the manufacturer s warehouse by the independent expert or testing institute entrusted with monitoring under the provisions of Section 3. The radiators selected for this purpose are to be provided with permanent labelling. The holder of the label will arrange for transportation of the radiator to the testing laboratory after discussion and agreement with the laboratory Submission of proof of conformity The complete copy of all reports (see sub-section 2.1.3) necessary for validly substantiating conformity to the Standards have to be available to the Quality Committee. Page 5
7 2.1.2 Scope of tests to substantiate conformity to Standards The following supplements EN sub-section 5.2 for establishing the scope of inspections: Model testing Model testing is the inspection of a radiator with a certain height, length, and depth as defined in EN Model series testing All radiators of a given design in which the geometric differences between the individual models in one characteristic dimension give rise to the expectation of a permanent change in their heat output can be allocated to a model series. Such a characteristic dimension can be deemed to exist, for instance, in: the structural height of the radiator, or the division of the elements of the radiator alongside one another, e.g. sections or pipes, or the number of identical elements of the radiator one behind another (in one or two rows), expressed in its structural depth, or the structural length if, contrary to the assumption contained in EN sub-section , does not change in a linear proportion to the structural length, e.g. radiators with cross-sectional flow and connectionns at the bottom opposite end. Changes in a second characteristic dimension require allocation to a new model series A model triangle is deemed to exist as a special form of a model series if, for instance, different heights of the convector panel are linked to the structural height of the radiator as a characteristic dimension. The model series testing consists of model testing on models selected in accordance with EN sub-section 5.2 and the calculation of the heat output of all models in the model series on the basis of the relevant regression calculation. In the case of model triangles sub-section 5.2 of EN is applied both to the structural height of the radiator and of the convector, with the radiators that form the three sides of the model triangle above 300 mm in structural height (the characteristic dimension) being regarded as the model series. The radiator at the corner point must always be inspected. If the structural height range is less than 300 mm, two tests will be sufficient instead of three. The same also applies to the characteristic dimension. Appendix B1 shows the selection of samples for testing for this case, taking three typical triangles as examples Model family testing A model family testing is an inspection of more than two model series that belong to a model family. A model family in the broader sense exists if all the models in the relevant model series are made up of uniform basic elements such as the panels that carry the water and the convector panels but no permanent relationship is to be expected between the structural depth and the heat output (see Appendix B 2.1). A model family in the narrower sense exists if more than one characteristic (primary or secondary) dimension gives rise to the expectation of a permanent dependency of the heat output (see Appendix B 3.1). Appendices B 2.2 and B 3.2 show the selection of the models to be tested on the basis of typical examples Special criteria for the selection of the models for testing If radiators are sold either with or without cladding, at the customer s choice, at least one model in the model series or family has to be subjected to supplementary inspection without cladding. If the deviations are shown to be more than 4 %, the model without cladding has to be regarded as a model series or family in its own right. If radiators are sold either with or without valve fittings, at the customer s choice, at least one model in the model series or family has to be subjected to supplementary test. If the deviations are shown to be more than 4 %, these have to be regarded as a model series or family in its own right. If the construction of the radiator in practice, or the way it is presented in the manufacturer s documentation, gives rise to the expectation that some form of connection has been included other than one that complies with EN subsection 6.3.1, the performance test has to be carried out with this kind of connection. In addition to this the testing laboratory will also define the number of models that may have to be tested additionally in order to enable a definitive statement to be made about the heat output of all the models Types of tests for proof of conformity to Standards Initial test for proof of conformity to Standards An initial test is an essential requirement for issuing valid substantiation of conformity to Standards. The substantiation that the radiator has passed the initial test for conformity to Standards is a complete test report. The test report must be issued on the forms laid down in EN Appendix E (or as a computer print-out with the same layout). It also has to contain a completely filled in data sheet as shown in Appendix C and a confirmed dimensional sketch of the radiator in DIN A4 format, with all the data relevant to heat output. Various examples are listed in EN Appendix G Secondary test A secondary test has to be carried out within 12 months of the initial test, or at the least the customer has to be able to show that he has requested one within this period of time. The secondary test consists of model testing and testing of the labelling. It covers one radiator from each model series, or 3 in the case of model triangles. In the case of model families with n model series, radiators from n/2 model series (rounded) have to be submitted to secondary test. If standard heat output figures emerge from the secondary test that deviate by more than 4% from the catalogue output according to EN 442, or if dimensions are measured that exceed the maximum deviations laid down in EN Page 6
8 Table 3, Section 5 of the Executive Regulations will take effect. The substantiation that the radiator has passed the secondary test is a complete test report in compliance with subsection If the data sheet and the dimensional sketch have not been altered from the last time conformity to Standards was substantiated, a note to this effect on the test report will be sufficient Follow-up test for conformity with Standards Radiators that have been tested have to be submitted to a follow-up test in order to confirm that they conform to the radiators that were submitted to the initial conformity test. The follow-up test is carried out within a period of 5 years after the initial conformity test. The nature and scope of these tests corresponds to the secondary test described in sub-section , with the necessary tests being distributed evenly over this five-year period. The same regulations apply to the proof that the radiators have passed the follow-up test as to the secondary test Check test If there is any doubt about whether a radiator that bears the label of quality actually does conform to the Standards, a check test can be requested. The check test basically has to be carried out as a model inspection on 2 equal models as described in sub-section The request for the check test basically has to be placed with the testing laboratory that carried out the initial test of the radiator in question. The client for the check test is the Association but the costs of this procedure have to be born by the applicant (complainant). These costs include the testing laboratory s fee, the cost for selecting and transporting the relevant radiator to the testing laboratory, and the cost of the radiator itself. If the check test reveals deviations that fall short of the readings obtained from the initial test by more than 4%, or if dimensions are discovered that exceed the limit deviations set by EN Table 2, the Executive Committee of the Association will inform the label-holder accordingly. He then has the right to examine the matter. Otherwise Section 5 of the Executive Regulations will apply. The substantiation that the radiator has passed the check test is a complete test report in compliance with sub-section If the data sheet and the dimensional sketch have not been altered from the last time conformity to Standards was substantiated, a note to this effect on the test report will be sufficient Supplementary test A supplementary test is a test for the purpose of establishing the effect of technical changes on the heat output of radiators that have already been tested for quality. The testing laboratory investigates the effect of the change on heat output by means of a visual check and, at its own free discretion, carrying out one or more model testings. If the supplementary test reveals a deviation of up to plus or minus 4% of the measured standard heat output, it will be permissible for the old values for the model series to be used. If the supplementary test reveals any greater deviation than ± 4%, any negative deviation of up to -6% will be treated as substantiating the percentage converted values. If there is a positive deviation of up to +6%, the conversion can be deleted upon the applicant's request so that the lower values will be regarded as having been substantiated. If the deviation is greater than 6% a fresh test will have to be carried out in accordance with sub-section or as an initial test to substantiate conformity with the Standards. The findings of the supplementary test have to be shown as follows: in the case of an assessment based on a visual check: by a written confirmation; if readings have been taken: by a complete report in accordance with sub-section on the tests with the scope defined above; This report will contain, for the whole related model series / family: either or the previous heat output figures or the ones that now have to be used, the conversion of the previous heat output figures or the ones that now have to be used. if a new initial test has to be carried out, a complete inspection report in accordance with sub-section , if the data sheet and dimensional sketch of the radiator are unchanged from the previous substantiation of conformity, a note to this effect on the test report will be sufficient. 2.2 Materials The quality of the material (for minimum requirements see EN sub-section 5.1) has to be demonstrated with the relevant tests in the manufacturer s own laboratory or by a works certificate in compliance with EN Dimensions and limits The dimensions laid down in the construction drawings must be adhered to and must lie within the stated limits. In addition to the limits stated in EN Table 3, those for certain radiator models shown in Appendix A to these quality and inspection regulations must not be exceeded either. The limits can be further tightened by data in the construction drawings. The limits on the thickness of parts that do not carry water such as the convection plates must not exceed the standard limits according to EN If no tolerances are shown for other dimensions, the coarse tolerance group (identification c ) defined in ISO will apply. Page 7
9 2.4 Processing Base material Base materials have to be stored and processed in such a way that there can be no deleterious effect on the surface through mechanical damage or corrosion. The base material is to be labelled in such a way that there can be no confusion and the quality of the material can be demonstrated at any time Joining process The production process that is used, and in particular the welding and other joining processes, must be tested and shown to be reliable for the process, and must also comply with the latest state of the technical art. All design characteristics laid down for the joining techniques such as the lengths of the welding seams, the number of welding spots, and the distance between them have to be defined in the manufacturing drawings, and the production process has to adhere to them. The construction and function of the joining machinery including any jigs and tools and the adjustment of the settings must be decided on the basis of the results of trials and destructive tests on samples and should also be documented Working pressures and pressure tests In addition to the tests for pressure resistance required by EN sub-section 5.3, the radiators have to be subjected to a burst test. The conditions and minimum values for excess pressure are laid down in the Appendix for the individual types. 2.5 Coating Priming coat Each radiator has to be provided with a priming coat in compliance with DIN , Coatings for radiators, on all the surfaces that are exposed to the air. Substantiation for adequate protection from the coating is provided if the necessary tests have been carried out successfully in compliance with DIN and recorded in a test report. The tests have to be carried out once. The materials and processes stated in the test report in compliance with DIN for the selection of samples must also be adhered to accordingly in the production of the radiators. If changes are made in the pre-treatment, the processing, or the coating material, the quality of the coating must be substantiated by means of a fresh test Finishing coat If radiators are sold ready painted, they have to be provided with a finishing coat in compliance with DIN , Coatings for radiators. Substantiation for adequate protection from the coating is provided if the necessary tests have been carried out successfully in compliance with DIN and recorded in a test report. The tests have to be carried out once. The materials and processes stated in the test report in compliance with DIN for the selection of samples must also be adhered to accordingly in the production of the radiators. If changes are made in the pre-treatment, the processing, or the coating material, the quality of the coating must be substantiated by means of a fresh test. Care must be taken to ensure that the coating provides adequate protection from mechanical damage during correct and proper transportation and storage until the radiator is installed. 2.6 Data in printed matter The data stated in the inspection reports will have a binding effect on all data in the manufacturer s printed matter. Heat outputs stated in the manufacturer s printed matter that are not in line with the standard conditions must be converted by using the equation of the characteristic curve taken from the relevant test report as defined in sub-section Monitoring Adherence to the quality regulations for radiators by the user of the quality label is checked by monitoring. This consists of the initial test, internal and external inspection. When the initial test has been carried out (3.1) external inspection (3.3) has to be requested from independent experts or testing organisations accepted by the Executive Committee, 3.1 Initial inspection The initial inspection is an essential requirement for approval to bear the RAL quality label. It includes the following elements: substantiation of conformity to the Standards, adherence to the quality and testing regulations, substantiation of a reliable inspection system. If the initial inspection cannot be successfully completed, a repetition of the initial inspection will be necessary within the next six months to see whether the points giving rise to complaint have been eliminated. If this six-month period has expired, a fresh initial inspection will have to be carried out Substantiation of conformity to Standards The inspection is made to see whether all the documentation is available for which provision is made in the procedure for substantiation of conformity to Standards (2.1.1) Adherence to quality and inspection regulations An adequate number of samples is taken to ensure adherence to these quality and inspection regulations and the fulfilment of the requirements for the product under these quality and inspection regulations and the relevant appendices. The radiators to be used for this purpose are selected by the examiner from current production or from the works warehouse. Page 8
10 The data in the Appendix on the obligation note have to be checked by the examiner for conformity to the Standards and for the correct application in the brochures and confirmed in the test report Substantiation of a reliable internal inspection system The applicant must substantiate that the requirements are being met for a reliable quality management system. 3.2 Internal inspection The user of the quality label has to constantly monitor all the requirements of the quality and inspection regulations and their appendices. For this purpose it is necessary to create, document, and maintain a quality management system that at least complies with EN ISO 9001 or equivalent and is able to produce objective substantiation that materials and manufacture, regardless of whether they are produced by the user of the label himself or bought in from suppliers, meet the specified requirements. Organisations that have previously used EN ISO 9002 have to apply EN ISO 9001 by excluding certain requirements defined in sub-section 1.2 of EN ISO The documentation from the internal inspection system have to be stored for at least 5 years and submitted to the inspection organisation. 3.3 External Inspection In order to guarantee a uniform level of quality, and to ensure that certified radiators bear the label of quality continue to conform to the one inspected in the initial test, inspection has to be carried out once a year by an external organisation Substantiation of conformity to Standards An inspection is made to ensure that all documentation is available that is envisaged in the procedure for substantiating conformity to Standards (2.1.1) Testing of labelling The labelling is tested to ensure that it is complete and is correctly and properly attached Adherence to these quality and test regulations An adequate number of samples is taken to ensure adherence to these quality and test regulations and the fulfilment of the requirements for the product under these quality and test regulations and the relevant appendices. The radiators to be used for this purpose are selected by the examiner from current production or from the works warehouse Substantiation of a reliable internal monitoring system The quality label user must substantiate that the requirements are being met for a reliable quality management system in accordance with sub-section Monitoring changes It is necessary to establish whether radiators have been modified since the last test, and whether the Association was informed of the changes in good time. For this purpose the user of the quality label has to hand over a Confirmation that the appendix to the note of obligation is up to date (Appendix D) and to establish whether any report has been received from a testing laboratory in compliance with subsection 2.1 on the performance of the necessary supplementary test Rectification of defects Any defects identified by the inspection organisation are to be rectified immediately. If this is not possible a period for compliance of no more than 3 months has to be set. The Executive Committee will decide whether it is necessary for the inspection organisation to repeat its test when the defects have been rectified or whether a written assurance from the tested company that the defect has been rectified will be sufficient if a check is made at the next inspection. 3.4 Test report The findings of the tests described in sub-sections 3.1 and 3.3 are recorded in an test report. The applicant/licensee and the Association are each sent a copy of the inspection report. 3.5 Testing costs The costs of the initial test are borne by the applicant. The costs of the inspection and any check test for conformity to Standards will be borne by the user of the quality label. 4 Changes to certified radiators If a licensee makes changes to his inspection system, his production process, or any product with the quality label, he has to inform the Association without delay. If any changes are made to radiators with quality labels a supplementary test has to be carried out in accordance with sub-section and the findings sent to the Association. The Executive Committee of the Association will decide whether any additional external monitoring is necessitated by these changes. Page 9
11 5 Labelling Steel radiators that can be demonstrated to comply with these quality and inspection regulations can be labelled with the symbol illustrated below as soon as the Association has awarded the manufacturer the quality label for those radiators. 6 Amendments No amendments to the quality and inspection regulations shall have any validity unless RAL has given its prior written approval, and shall not come into effect until an appropriate length of time has passed after the Board of the Association has announced them to the users of the quality label. In addition to identifying his product with this label, the manufacturer also has to provide the following information: manufacturer s name or identification, identification of the place of manufacture (code), registration number (type / version), maximum working pressure. The manufacturer of the radiator must be identifiable both in the technical documentation and from his sales brochures in the form of either his name or his registration number. All labels must be easily legible and permanently affixed. Labelling with an adhesive label will be regarded as permanent for this purpose. The labelling must be attached to the radiator. In the case of radiators constructed in sections the labelling of individual sections or blocks of up to three sections can be omitted. The Executive Regulations for the awarding and holding of the quality label for steel radiators will apply exclusively to the application of the quality label. Page 10
12 Appendices to the quality and inspection regulations Appendix A Special requirements for specific radiator models Appendix B Selection of the models to be inspected in model series and families A 1 Quality requirements for panel radiators B 1 Model triangle : selection of models for inspection A 2 Quality requirements for tubular steel sectional radiators B 2 Model family in the broader sense A 3 Quality requirements for heated walls and convectors B 2.1 Typical example A 4 Quality requirements for bathroom and designer radiators made of pipe elements B 2.2 Selection of models for inspection A 5 Quality requirements for sectional steel radiators B 3 Model family in the narrower sense A 6 Quality requirements for ribbed tubular convectors B 3.1 Typical example B 3.2 Selection of models for inspection Appendix C Data sheet for radiators Appendix D Confirmation that the appendix to the obligation note is up to date Page 11
13 Appendix A 1: Quality requirements for panel radiators re 2.3 Dimensions and limits All data in mm Total construction depth ± 2.0 for 2-row radiators ± 2.5 for 3-row radiators Total construction height, multiple-row radiator Construction height of the individual panels ± 2,0 Construction length of the individual panels 800 ±2 Construction length of the individual panels > 800 ± 0.25% Maximum structural length off-set over entire length 3 All radiuses at the curvatures of the convector sheets + 1,0-2,0 Page 12
14 Curvature The permitted curvature x for panel radiators must not exceed x 4mm per 1000mm length. Measurement of the curvature x for model 10 and 11 panel radiators (refer to appendix B 2.1 and B 3.1) is to be performed in the horizontal position on the top or bottom water duct of the radiator during the manufacturing process, e.g. before the lacquering process or any further handling. Measurement of the curvature x for other panel radiator models (refer to appendix B 2.1 and B 3.1) is to be performed during the manufacturing process, e.g. before the lacquering process, on the top or bottom water duct of a vertical radiator. Incorrect positioning of the panel radiators results in a risk of the measured tolerance for curvature x (x 4 mm per 1000 mm length) measured during the manufacturing process may be exceeded. Consequently, the manufacturer must ensure correct positioning of the panel radiators during operation. As part of inspection, observance of the curvature x and correct positioning at the manufacturer s is controlled. The interval for the manufacturing control of curvature is to be performed analogously to the manufacturing control of the dimensions of the semi-finished and finished products. re Working pressures and pressure tests The working pressure of the radiator is at least 6 bar. In case of intermediate values for the pressure levels indicated, the requirements of the respective higher operating pressure are to be observed. Supplementing the test for pressure resistance required by EN sub-section 5.3, the manufacturer has to carry out burst tests. The guideline values for this, with the related warning and intervention limits corresponding to the relevant working pressure are shown in the following table. Working pressure in bar Test pressure 7,8 10,4 13 Guideline figure Warning limit Intervention limit All data are pressures above atmospheric pressure in bar If the guideline figure is exceeded by 15% the burst test can be terminated. The number of burst tests required is set in stages: Stage 1 1 test after 10 radiators on each production line 1 test after 100 radiators on each production line Stage 2 1 test per shift on each production line, Stage 3 1 test per day on each production line. Procedure for application Stage 1 is to use when: new production lines are being started up, major changes have been made in production lines, new welding parameters are being calculated, production is being changed over to a higher pressure level, when readings fall short of the intervention limit. This does not include: changes in construction height or length, model changes, coil changes, insignificant changes in welding equipment, electrode changes. If the readings do not fall short of the guideline figure after Stage 1, tests can be carried out in accordance with Stage 2. If the readings do not fall short of the guideline figure after 10 consecutive tests in Stage 2, Stage 3 can be applied. If the readings in any test fall short of the guideline figure but not of the warning limit, that Stage should be retained; only when once again 10 consecutive tests have been Page 13
15 carried out without falling short of the guideline figure can tests be carried out at the next higher Stage. If the readings in any test fall short of the warning limit, tests must then immediately be conducted according to the next lower Stage. When 10 consecutive tests have been conducted in which the readings did not fall short of the guideline figure, the subsequent tests can be carried out according to the next higher Stage. If the readings fall short of the intervention limit, tests will be carried out according to the necessary measures under Stage 1 with the subsequent test procedure. Action to be taken if readings fall short of the guideline figure Corrective action is necessary if the readings fall short of the guideline figure and the warning limit. They are to be laid down and documented in the Procedural Instructions under the quality assurance system. If the readings fall short of the intervention limit, care should be taken to ensure that a thorough investigation is made that production stops on this production line, and that all radiators produced before and after this sample was taken are not put to any other use until the problem has been completely clarified. Further samples should be taken and tested if necessary on these radiators. re 2.5 Coating To ensure a uniform level of quality in the coating a crosscut test should be made every day in accordance with EN ISO 2409 on the surface of a cool radiator outside the welding area and without any further conditioning. The cross-cut reading of Gt 1 should be attained as a minimum. re 3.2 Internal monitoring To ensure a uniform level of quality, the following specification should be met with regard to EN ISO 9001 for quality monitoring. re EN ISO 9001 sub-section 5.6 Management evaluation The user of the quality label must carry out a review and revision of the quality system at least once a year. re EN ISO 9001 sub-section 7.6 Management of monitoring and instrumentation equipment All items of measuring and testing equipment must be subjected to recurrent tests at the following intervals in order to ensure that all readings are accurate and that the equipment is not subject to any decline in accuracy. Manometers Micrometers All other measuring, testing, and monitoring instruments Testing normal (e.g.: final dimensions) Every 3 months Every 6 months Every year Every 5 years re EN ISO 9001 sub-section on the verification of bought-in products In the case of bought-in parts that have to withstand pressure, or that are relevant to the function and safety of the radiator, random samples have to be taken of incoming goods at the frequency shown below as a minimum: Number of samples per consignment (Stage 0) Up to 5,000 units 8 units, Up to 20,000 units 16 units, Over 20,000 units 20 units. Or corresponding time-dependent determination of the number of random samples which at least meets these requirements. Procedure for defects (acceptance / rejection) If defects are discovered in the samples (acceptance = zero defects, rejection = one defect), a further test has to be carried out. If this also reveals defects, the entire consignment has to be sent back to the supplier or other suitable measures have to be taken to ensure that no defective bought-in parts find their way into production. If consignments are no longer defective, the quality control checks on incoming goods can be reduced in stages: Stage 1: When three consignments have arrived and revealed no defects the test can return to Stage 0 with half the number of units or, at the manufacturer s choice, only every second consignment needs to be checked. Stage 2: When three more consignments have been delivered with no cause for complaint, the test level can be reduced to Stage 0 with one fourth of the number of units or, at the manufacturer s choice, only every fourth consignment needs to be checked. If any consignment within the three Stages is defective, after that inspection must start again at Stage 0. These checks on incoming goods can be omitted if there is some other way of verifying that the quality requirements for the bought-in parts are being met by a quality assurance system at the supplier s end that meets the stated minimum requirements. re EN ISO 9001 sub-section on monitoring and measuring the product The following requirements have to be made on the control specifications for production quality control checks: Base material: Sheet thickness Sheet widths Dimensions and curvature of semifinished and finished goods: 2 per coil, min. 2 per shift 2 per coil, min. 2 per shift 2 per radiator type (or design), min. 2 per shift. If defects are discovered by production control checks a further test has to be carried out. If this likewise reveals defects, suitable steps have to be taken to ensure that later products are not affected by any further defects. Page 14
16 Appendix A 2: Quality requirements for tubular steel sectional radiators re 2.3 Dimensions and limits Element offset Front view Buckle/Saddle Front view Angularity Front view Element offset Top view Curvature Top view Angularity Top view Ratation Main surfaces Plan-parallel alignment End-element/Bush connection area Property Designation Permissible deviation Comments Element offset Front view V1 1.5 mm From element to element V2 2.5 mm Over entire block length Top view V3 1.5 mm From element to element V4 2.5 mm Over entire block length Buckle / saddle X 4 mm/1000 mm ML ML = measurement length Curvature X 4 mm/1000 mm ML ML = measurement length Angularity Front view X 5 mm/1000 mm ML ML = measurement length Top view X 5 mm/1000 mm ML ML = measurement length Rotation X 1 mm/100(bh) 1000(BL) Plan-parallel alignment X 1 mm/100 mm ML ML = measurement length The values in EN table 3 must at least be complied with for all other dimensions, e.g. total construction height. 1 1 (BH) = construction height; (BL) = construction length Page 15
17 DIN 2394 applies to the tolerances of tubes. Complete radiators with a construction length of 1000 mm should be used for the dimensional test. They must stand or lie on a level surface. re Working pressure and pressure tests The permissible working pressure of a tubular steel sectional radiator is at least 10 bar. In case of intermediate values for the pressure levels indicated, the requirements of the respective higher operating pressure are to be observed. In addition to the test of pressure resistance under EN sub-section 5.3, the manufacturer also has to carry out burst tests. The guideline figures for these tests and their related warning and intervention limits for each level of working pressure are shown in the following table. Complete radiators with a construction length of at least 500 mm are to be used for the burst test. Working pressure Testing pressure Guideline figure Warning limit Intervention limit All figures show pressure over atmospheric pressure in bar If the guideline figure is exceeded by 15% the burst test can be terminated. The number of burst tests required is divided into Stages: Stage 1 1 test after 12 sections on each production line, 1 test after 500 sections on each production line, Stage 2 1 test on each working day and production line, Stage 3 1 test at intervals of no more than 5 working days on each production line. Procedure for application Stage 1 is to use when: new production lines are being started up, major changes have been made in production lines, new welding parameters are being calculated, production is being changed over to a higher pressure level, when readings fall short of the intervention limit. This does not include: changes in construction height or length, model changes, insignificant changes in welding equipment, If the readings do not fall short of the guideline figure after Stage 1, tests can be carried out in accordance with Stage 2. If the readings do not fall short of the guideline figure after 10 consecutive tests in Stage 2, Stage 3 can be applied. If the readings in any test fall short of the guideline figure but not of the warning limit, that Stage should be retained; only when once again 10 consecutive tests have been carried out without falling short of the guideline figure can tests be carried out at the next higher Stage. If the readings in any test fall short of the warning limit, tests must then immediately be conducted according to the next lower Stage. When 10 consecutive tests have been conducted in which the readings did not fall short of the guideline figure, the subsequent tests can be carried out according to the next higher Stage. If the readings fall short of the intervention limit, tests will be carried out according to the necessary measures under Stage 1 with the subsequent test procedure. Action to be taken if readings fall short of the guideline figure Corrective action is necessary if the readings fall short of the guideline figure and the warning limit. They are to be laid down and documented in the Procedural Instructions under the quality assurance system. If the readings fall short of the intervention limit, care should be taken to ensure that a thorough investigation is made that production stops on this production line, and that all radiators produced before and after this sample was taken are not put to any other use until the problem has been completely clarified. Further samples should be taken and tested if necessary on these radiators. The burst test can be omitted if there is any other way of ensuring that the quality requirements for pressure resistance are being met for the whole radiator, and particularly at the joints (weld joints, etc.) by a quality assurance system that meets the above minimum requirements. The auditor has to check the effectiveness of the system. re 2.5 Coating To ensure a uniform level of quality in the coating a crosscut test should be made every day in accordance with DIN EN ISO 2409 on the surface of a radiator outside the welding spots. Following the cooling of the radiator to ambient temperature further conditioning is not necessary. The cross-cut reading of Gt 1 should be attained as a minimum. re 3.2 Internal monitoring To ensure a uniform level of quality, the following specification should be met with regard to EN ISO 9001 for quality monitoring. re EN ISO 9001 sub-section 5.6 Management evaluation The user of the quality label must carry out a review and revision of the quality system at least once a year. re EN ISO 9001 sub-section 7.6 Management of monitoring and instrumentation equipment All items of measuring and testing equipment must be subjected to recurrent testings at the following intervals in order to ensure that all readings are accurate and that the equipment is not subject to any decline in accuracy. Page 16
18 Manometers (for radiator tests) Micrometers All other measuring, testing, and monitoring instruments Testing normal (e.g.: final dimensions) Every 3 months Every 6 months Every year Every 5 years re EN ISO 9001 sub-section on the verification of bought-in products In the case of bought-in parts that have to withstand pressure, or that are relevant to the function and safety of the radiator, random samples have to be taken of incoming goods at the frequency shown below as a minimum: Number of samples per consignment (Stage 0) Up to 5,000 units 8 units, Up to 20,000 units 16 units, Over 20,000 units 20 units. Or corresponding time-dependent determination of the number of random samples which at least meets these requirements. Procedure for defects (acceptance / rejection) If defects are discovered in the samples (acceptance = zero defects, rejection = one defect), a further test has to be carried out. If this also reveals defects, the entire consignment has to be sent back to the supplier or other suitable measures have to be taken to ensure that no defective bought-in parts find their way into production. If consignments are no longer defective, the checks on incoming goods can be reduced in stages: Stage 1: When three consignments have arrived and revealed no defects the inspection can return to Stage 0 with half the number of units or, at the manufacturer s choice, only every second consignment needs to be checked. Stage 2: When three more consignments have been delivered with no cause for complaint, the test level can be reduced to Stage 0 with one fourth of the number of units or, at the manufacturer s choice, only every fourth consignment needs to be checked. If any consignment within the three Stages is defective, after that tests must start again at Stage 0. These checks on incoming goods can be omitted if there is some other way of verifying that the quality requirements for the bought-in parts are being met by a quality assurance system at the supplier s end that meets the stated minimum requirements. re EN ISO 9001 sub-section on monitoring and measuring the product The following requirements have to be made on the control specifications for production quality checks unless these have already been covered by the check on incoming goods: Base material: Sheet thickness Dimensions of semi-finished and finished goods: 2 per coil, per radiator type (or design), 2 per shift. If defects are discovered by production quality checks a further test has to be carried out. If this likewise reveals defects, suitable steps have to be taken to ensure that later products are not affected by any further defects. Page 17
19 Appendix A 3: Quality requirements for heating walls and convectors re 2.3 Dimensions and limits Horizontal design Property Nominal dimension range Designation type H Permissible deviation Comments Total construction height Total construction depth Total construction length 600 mm HH + 4 / - 2 mm > 600 mm HH + 1% / - 0.5% TH ± 2 mm TH1 ± 2 mm TH2 + 4 / - 2 mm TH3 + 4 / - 2 mm All multi-layer 1000 mm LH ± 4 mm > 1000 mm 3000 mm LH ± 5 mm > 3000 mm LH ± 0.25% Convector panel height KHH + 3 / - 1 mm Convector panel depth KTH ± 1 mm Bush separation 300 mm AHH / AHV ± 2 mm > 300 mm 1000 mm AHH / AHV ± 4 mm > 1000 mm 3000 mm AHH / AHV ± 5 mm > 3000 mm AHH / AHV ± 0.25% Page 18
20 re 2.3 Dimensions and limits Vertical design Property Nominal dimension range Designation type V Permissible deviation Comments Total construction height Total construction depth Total construction length 1000 mm HV ± 4 mm > 1000 mm 3000 mm HV ± 5 mm > 3000 mm HV ± 0.25% TV TV1 TV2 ± 2 mm ± 2 mm + 4 / - 2 mm 600 mm LV ± 4 mm > 600 mm LV + 1% / - 0.5% Convector panel height KHV + 3 / - 1 mm Convector panel depth KTV ± 1 mm Bush separation 300 mm AVV / AVH ± 2 mm > 300 mm 1000 mm AVV / AVH ± 4 mm > 1000 mm 3000 mm AVV / AVH ± 5 mm > 3000 mm AVV / AVH ± 0.25% re Working pressure and pressure tests The permissible working pressure of heating walls and convectors made of flat pipes is at least 4 bar. In case of intermediate values for the pressure levels indicated, the requirements of the respective higher operating pressure are to be observed. In addition to the test of pressure resistance under EN sub-section 5.3, the manufacturer also has to carry out burst tests. The guideline figures for these tests and their related warning and interventions limits for each level of working pressure are shown in the following table. Complete radiators with a construction length of at least 500 mm are to be used for the burst test. Working pressure Testing pressure Guideline figure Warning limit Intervention limit All figures show pressure over atmospheric pressure in bar If the guideline figure is exceeded by 15% the burst test can be terminated. The number of burst tests required is divided into Stages: Stage 1 Stage 2 Stage 3 1 test after 10 radiator units on each production line, 1 test on each working day and production line, 1 test at intervals of no more than 5 working days on each production line. Page 19
21 Procedure for application Stage 1 is to use when: new production lines are being started up, major changes have been made in production lines, new welding parameters are being calculated, when readings fall short of the intervention limit. This does not include: changes in construction height or length, model changes, insignificant changes in welding equipment. If the readings do not fall short of the guideline figure after Stage 1, tests can be carried out in accordance with Stage 2. If the readings do not fall short of the guideline figure after 10 consecutive tests in Stage 2, Stage 3 can be applied. If the readings in any test fall short of the guideline figure but not of the warning limit, that Stage should be retained; only when once again 10 consecutive tests have been carried out without falling short of the guideline figure can tests be carried out at the next higher Stage. If the readings in any test fall short of the warning limit, tests must then immediately be conducted according to the next lower Stage. When 10 consecutive tests have been conducted in which the readings did not fall short of the guideline figure, the subsequent tests can be carried out according to the next higher Stage. If the readings fall short of the intervention limit, tests will be carried out according to the necessary measures under Stage 1 with the subsequent test procedure. Action to be taken if readings fall short of the guideline figure Corrective action is necessary if the readings fall short of the guideline figure and the warning limit. They are to be laid down and documented in the Procedural Instructions under the quality assurance system. If the readings fall short of the intervention limit, care should be taken to ensure that a thorough investigation is made that production stops on this production line, and that all radiators produced before and after this sample was taken are not put to any other use until the problem has been completely clarified. Further random samples should be taken and tested if necessary on these radiators. The burst test can be omitted if there is any other way of ensuring that the quality requirements for pressure resistance are being met for the whole radiator, and particularly at the joints (weld joints, etc.) by a quality assurance system that meets the above minimum requirements. The auditor has to check the effectiveness of the system. re 2.5 Coating To ensure a uniform level of quality in the coating a crosscut test should be made every day in accordance with DIN EN ISO 2409 on the surface of a radiator outside the welding spots. No further conditioning of this sample is necessary after the radiator has cooled down to room temperature. The cross-cut reading of Gt 1 must not be exceeded as a maximum. re 3.2 Inspection To ensure a uniform level of quality, the following specification should be met with regard to EN ISO 9001 for quality monitoring. re EN ISO 9001 sub-section 5.6 Management evaluation The user of the quality label must carry out a review and revision of the quality system at least once a year. re EN ISO 9001 sub-section 7.6 Management of monitoring and instrumentation equipment All items of measuring and testing equipment must be subjected to recurrent tests at the following intervals in order to ensure that all readings are accurate and that the equipment is not subject to any decline in accuracy. Manometers (for radiator tests) Micrometers All other measuring, testing, and monitoring instruments Testing normal (e.g.: final dimensions) Every 3 months Every 6 months Every year Every 5 years re EN ISO 9001 sub-section on the verification of bought-in products In the case of bought-in parts that have to withstand pressure, or that are relevant to the function and safety of the radiator, random samples have to be taken of incoming goods at the frequency shown below as a minimum Number of samples per consignment (Stage 0) Up to 5,000 units 8 units, Up to 20,000 units 16 units, Over 20,000 units 20 units. Or corresponding time-dependent determination of the number of random samples which at least meets these requirements. Procedure for defects (acceptance / rejection) If defects are discovered in the samples (acceptance = zero defects, rejection = one defect), a further test has to be carried out. If this also reveals defects, the entire consignment has to be sent back to the supplier or other suitable measures have to be taken to ensure that no defective bought-in parts find their way into production. If consignments are no longer defective, the quality control checks on incoming goods can be reduced in stages: Stage 1: When three consignments have arrived and revealed no defects the test can return to Stage 0 with half the number of units or, at the manufacturer s choice, only every second consignment needs to be checked. Stage 2: When three more consignments have been delivered with no cause for complaint, the test level can be reduced to Stage 0 with one fourth of the number of units or, at the manufacturer s choice, only every fourth consignment needs to be checked. Page 20
22 If any consignment within the three Stages is defective, after that inspection must start again at Stage 0. These checks on incoming goods can be omitted if there is some other way of verifying that the quality requirements for the bought-in parts are being met by a quality assurance system at the supplier s end that meets the stated minimum requirements. re EN ISO 9001 sub-section on monitoring and measuring the product The following requirements have to be made on the control specifications for production quality checks unless these have already been covered by the check on incoming goods: Base material: Sheet thickness Sheet width Dimensions of semi-finished and finished goods: 2 per coil, min. 2 per shift 2 per coil, min. 2 per shift per radiator type (or design), 2 per shift. If defects are discovered by production quality checks a further test has to be carried out. If this likewise reveals defects, suitable steps have to be taken to ensure that later products are not affected by any further defects. Page 21
23 Appendix A 4: Quality requirements for bathroom and designer radiators This covers all types of radiator that cannot be clearly allocated to any of Appendices A1 to A3. re 2.3 Dimensions and limits Property Nominal dimension range Designation type V Permissible deviation Comments Total construction height Total construction depth Total construction length Length of individual pipes Bush separation 800 mm BH + 4 / - 2 mm >800 to 1200 mm BH + 5 / - 2 mm See 2 > 1200 mm BH + 6 / - 2 mm Single-row BT ± 1.5 mm Double-row BT ± 1.5 mm See 2 Multiple-row BT ± 1.5 mm 600 mm BL ± 3 mm > 600 mm to 1000 mm BL ± 4 mm See 2 > 1000 mm BL ± 0.5% 600 mm RL ± 2 mm See 2 > 600 mm RL ± 3 mm 600 mm NA ± 2 mm > 600 mm to 1000 mm NA ± 4 mm > 1000 mm to 3000 mm NA ± 5 mm > 3000 mm NA ± 0.25% 2 For bathroom and designer radiators with different shapes (particularly those with curved elements), the tolerances shown in the manufacturer s drawings have to be observed for the total construction depth that is formed by these curved elements, but subject to a maximum of. ± 5 mm. Page 22
24 re Working pressures and pressure tests The permissible working pressure for bathroom and designer radiators made of tubular elements is at least 4 bar. In case of intermediate values for the pressure levels indicated, the requirements of the respective higher operating pressure are to be observed. Supplementing the test for pressure resistance required by EN sub-section 5.3, the manufacturer has to carry out burst tests. The guideline values for this, with the related warning and intervention limits corresponding to the relevant working pressure are shown in the following table. Complete radiators with a construction length of at least 500 mm are to be used for the burst test. Working pressure Testing pressure Guideline figure Warning limit Intervention limit All figures show pressure over atmospheric pressure in bar If the guideline figure is exceeded by 15% the burst test can be terminated. The number of burst tests required is divided into Stages: Stage 1 Stage 2 Stage 3 1 test after 10 radiator units on each production line, 1 test on each working day and production line, 1 test at intervals of no more than 5 working days on each production line. Procedure for application Stage 1 is to use when: new production lines are being started up, major changes have been made in production lines, new welding parameters are being calculated, readings fall short of the intervention limit. This does not include: changes in construction height or length, model changes, insignificant changes in welding equipment, If the readings do not fall short of the guideline figure after Stage 1, tests can be carried out in accordance with Stage 2. If the readings do not fall short of the guideline figure after 10 consecutive tests in Stage 2, Stage 3 can be applied. If the readings in any test fall short of the guideline figure but not of the warning limit, that Stage should be retained; only when once again 10 consecutive tests have been carried out without falling short of the guideline figure can tests be carried out at the next higher Stage. If the readings in any test fall short of the warning limit, tests must then immediately be conducted according to the next lower Stage. When 10 consecutive tests have been conducted in which the readings did not fall short of the guideline figure, the subsequent tests can be carried out according to the next higher Stage. If the readings fall short of the intervention limit, tests will be carried out according to the necessary measures under Stage 1 with the subsequent test procedure. Action to be taken if readings fall short of the guideline figure Corrective action is necessary if the readings fall short of the guideline figure and the warning limit. They are to be laid down and documented in the Procedural Instructions under the quality assurance system. If the readings fall short of the intervention limit, care should be taken to ensure that a thorough investigation is made that production stops on this production line, and that all radiators produced before and after this sample was taken are not put to any other use until the problem has been completely clarified. Further random samples should be taken and tested if necessary on these radiators. The burst test can be omitted if there is any other way of ensuring that the quality requirements for pressure resistance are being met for the whole radiator, and particularly at the joints (weld joints, etc.) by a quality assurance system that meets the above minimum requirements. The auditor has to check the effectiveness of the system. re 2.5 Coating To ensure a uniform level of quality in the coating a crosscut test should be made every day in accordance with DIN EN ISO 2409 on the surface of a radiator outside the welding area. No further conditioning of this sample is necessary after the radiator has cooled down to room temperature. The cross-cut reading of Gt 1 must not be exceeded as a maximum. re 3.2 Internal monitoring To ensure a uniform level of quality, the following specification should be met with regard to EN ISO 9001 for quality monitoring. re EN ISO 9001 sub-section 5.6 Management evaluation The user of the quality label must carry out a review and revision of the quality system at least once a year. re EN ISO 9001 sub-section 7.6 Management of monitoring and instrumentation equipment All items of measuring and testing equipment must be subjected to recurrent testing at the following intervals in order to ensure that all readings are accurate and that the equipment is not subject to any decline in accuracy. Manometers (for radiator tests) Micrometers All other measuring, testing, and monitoring instruments Testing normal (e.g.: final dimensions) Every 3 months Every 6 months Every year Every 5 years re EN ISO 9001 sub-section on the verification of bought-in products In the case of bought-in parts that have to withstand pressure, or that are relevant to the function and safety of the
25 radiator, random samples have to be taken of incoming goods at the frequency shown below as a minimum Number of samples per consignment (Stage 0) Up to 5,000 units 8 units, Up to 20,000 units 16 units, Over 20,000 units 20 units. Or corresponding time-dependent determination of the number of random samples which at least meets these requirements. Procedure for defects (acceptance / rejection) If defects are discovered in the samples (acceptance = zero defects, rejection = one defect), a further test has to be carried out. If this also reveals defects, the entire consignment has to be sent back to the supplier or other suitable measures have to be taken to ensure that no defective bought-in parts find their way into production. If consignments are no longer defective, the quality control checks on incoming goods can be reduced in stages: Stage 1: When three consignments have arrived and revealed no defects the test can return to Stage 0 with half the number of units or, at the manufacturer s choice, only every second consignment needs to be checked. Stage 2: When three more consignments have been delivered with no cause for complaint, the test level can be reduced to Stage 0 with one fourth of the number of units or, at the manufacturer s choice, only every fourth consignment needs to be checked If any consignment within the three Stages is defective, after that inspection must start again at Stage 0. These tests on incoming goods can be omitted if there is some other way of verifying that the quality requirements for the bought-in parts are being met by a quality assurance system at the supplier s end that meets the stated minimum requirements. re EN ISO 9001 sub-section on monitoring and measuring the product The following requirements have to be made on the control specifications for production quality checks unless these have already been covered by the check on incoming goods: Dimensions of semi-finished and finished goods: per radiator type (or design), 2 per shift. If defects are discovered by production quality checks a further tests has to be carried out. If this likewise reveals defects, suitable steps have to be taken to ensure that later products are not affected by any further defects. Page 24
26 Appendix A 5: Quality requirements for steel element radiators re 2.3 Dimensions and limits V1 V2 X X Element Gliedversatz offset Vorderansich Front view t V3 V4 Buckle Buckel/Sattel / saddle Vorderansich Front view t X WAngularity inkeligkeit Vorderansic Front view ht X Element Gliedversatz offset Draufsich Top view t X Durchbiegung Curvature Draufsicht Top view X WAngularity inkeligkeit DTop raufsicht view Verdrallun Rotation g Hauptflächen Main surfaces Plan-parallel Planparallelität alignment Endglieder/Nabenanschlußfläche End-element / Bush connection area Property Designation Permissible deviation Comments Element offset Front view V1 1.5 mm From element to element V2 2.5 mm Over entire block length Top view V3 1.5 mm From element to element V4 2.5 mm Over entire block length Buckle / saddle X 4 mm/1000 mm ML ML = measurement length Curvature X 4 mm/1000 mm ML ML = measurement length Angularity Front view X 5 mm/1000 mm ML ML = measurement length Top view X 5 mm/1000 mm ML ML = measurement length Rotation X 1 mm/100(bh) 1000(BL) *) Plan-parallel alignment X 1 mm/100 mm ML ML = measurement length *) (BH) = construction height; (BL) = construction length The values in EN table 3 must at least be complied with for all other dimensions e.g. total construction height. Page 25
27 Complete radiators with a construction length of 1000 mm should be used for the dimensional test. They must stand or lie on a level surface. re Working pressure and pressure tests The permissible working pressure of a steel element radiator is at least 4 bar. In case of intermediate values for the pressure levels indicated, the requirements of the respective higher operating pressure are to be observed. In addition to the test of pressure resistance under EN sub-section 5.3, the manufacturer also has to carry out burst tests. The guideline figures for these tests and their related warning and interventions limits for each level of working pressure are shown in the following table. Complete radiators with a construction length of at least 500 mm are to be used for the burst test. Working pressure 4 6 Testing pressure Guideline figure 8 12 Warning limit Intervention limit All figures show pressure over atmospheric pressure in bar If the guideline figure is exceeded by 15% the burst test can be terminated. The number of burst tests required is divided into Stages: Stage 1 1 test after 12 elements on each production line, 1 test after 500 elements on each production line, Stage 2 1 test on each working day and production line, Stage 3 1 test at intervals of no more than 5 working days on each production line. Procedure for application Stage 1 is to use when: new production lines are being started up, major changes have been made in production lines, new welding parameters are being calculated, production is being changed over to a higher pressure level, when readings fall short of the intervention limit. This does not include: changes in construction height or length, model changes, insignificant changes in welding equipment, If the readings do not fall short of the guideline figure after Stage 1, tests can be carried out in accordance with Stage 2. If the readings do not fall short of the guideline figure after 10 consecutive tests in Stage 2, Stage 3 can be applied. If the readings in any test fall short of the guideline figure but not of the warning limit, that Stage should be retained; only when once again 10 consecutive tests have been carried out without falling short of the guideline figure can tests be carried out at the next higher Stage. If the readings in any test fall short of the warning limit, tests must then immediately be conducted according to the next lower Stage. When 10 consecutive tests have been conducted in which the readings did not fall short of the guideline figure, the subsequent tests can be carried out according to the next higher Stage. If the readings fall short of the intervention limit, tests will be carried out according to the necessary measures under Stage 1 with the subsequent test procedure. Action to be taken if readings fall short of the guideline figure Corrective action is necessary if the readings fall short of the guideline figure and the warning limit. They are to be laid down and documented in the Procedural Instructions under the quality assurance system. If the readings fall short of the intervention limit, care should be taken to ensure that a thorough investigation is made that production stops on this production line, and that all radiators produced before and after this sample was taken are not put to any other use until the problem has been completely clarified. Further random samples should be taken and tested if necessary on these radiators. re 2.5 Coating To ensure a uniform level of quality in the coating a crosscut test should be made every day in accordance with DIN EN ISO 2409 on the surface of a radiator outside the welding spots. No further conditioning of this sample is necessary after the radiator has cooled down to room temperature. The cross-cut reading of Gt 1 should be attained as a minimum. re 3.2 Internal monitoring To ensure a uniform level of quality, the following specification should be met with regard to EN ISO 9001 for quality monitoring. re EN ISO 9001 sub-section 5.6 Management evaluation The user of the quality label must carry out a review and revision of the quality system at least once a year. re EN ISO 9001 sub-section 7.6 Management of monitoring and instrumentation equipment All items of measuring and testing equipment must be subjected to recurrent testing at the following intervals in order to ensure that all readings are accurate and that the equipment is not subject to any decline in accuracy. Manometers (for radiator tests) Micrometers All other measuring, testing, and monitoring instruments Testing normal (e.g.: final dimensions) Every 3 months Every 6 months Every year Every 5 years re EN ISO 9001 sub-section on the verification of bought-in products In the case of bought-in parts that have to withstand pressure, or that are relevant to the function and safety of the radiator, random samples have to be taken of incoming goods at the frequency shown below as a minimum
28 Number of samples per consignment (Stage 0) Up to 5,000 units 8 units, Up to 20,000 units 16 units, Over 20,000 units 20 units. Or corresponding time-dependent determination of the number of random samples which at least meets these requirements. Procedure for defects (acceptance / rejection) If defects are discovered in the samples (acceptance = zero defects, rejection = one defect), a further test has to be carried out. If this also reveals defects, the entire consignment has to be sent back to the supplier or other suitable measures have to be taken to ensure that no defective bought-in parts find their way into production. If consignments are no longer defective, the quality control checks on incoming goods can be reduced in stages: Stage 1: When three consignments have arrived and revealed no defects the test can return to Stage 0 with half the number of units or, at the manufacturer s choice, only every second consignment needs to be checked. Stage 2: When three more consignments have been delivered with no cause for complaint, the test level can be reduced to Stage 0 with one fourth of the number of units or, at the manufacturer s choice, only every fourth consignment needs to be checked. If any consignment within the three Stages is defective, after that the tests must start again at Stage 0. These tests on incoming goods can be omitted if there is some other way of verifying that the quality requirements for the bought-in parts are being met by a quality assurance system at the supplier s end that meets the stated minimum requirements. re EN ISO 9001 sub-section on monitoring and measuring the product The following requirements have to be made on the control specifications for production quality checks unless these have already been covered by the check on incoming goods: Base material: Sheet thickness Dimensions of semi-finished and finished goods: 2 per coil per radiator type (or design), 2 per shift. If defects are discovered by production quality checks a further test has to be carried out. If this likewise reveals defects, suitable steps have to be taken to ensure that later products are not affected by any further defects. Page 27
29 Appendix A 6: Quality requirements for ribbed tube convectors re 2.2 Materials The ribs and tubes have to be made from corrosion-resistant materials, or materials that form their own protective layer, or else must be coated in accordance with sub-section 2.5. The same requirements apply to the housing, the shaft, and the cover if they are component parts of the product. re 2.3 Dimensions and limits Examples of ribbed tube convectors and their installation situations: Examples of rib shapes and dimensions: Property Designation Permissible deviations in mm Comments Housing dimensions HG TG ± 2.0 As defined in EN 442 LG Register construction HR ± 0.5 Height of complete register height Register construction TR ± 0.5 Depth of complete register depth Ribbed length LR ± 1.5 Rib dimensions RH RB ± As defined in EN 442 RD Rib thickness Rd ± 0.05 As defined in EN 442 Division of the register XR ± 0.5 Measured at the rib foot Number of ribs ZR ± 1.0 As defined in EN 442 Internal diameter of tubes RDi ± 0.10 As defined in EN 442. Only relevant to the manufacturer s statement of the output Page 28
30 Manufacturer s information Property Designation Permissible Comments deviations in mm Distance from bottom edge of register to bottom edge of housing TA ± 5 In the case of under-floor installation (with no housing) the distance from the bottom edge of the register to the floor is ± 10 mm Distance from side edge of register to side edge of housing BA ± 5 In the case of under-floor installation (with no housing) the distance from the side edge of the register to the wall is ± 10 mm Shaft width SB ± 2.0 Only for under-floor installation Shaft depth ST ± 2.0 Only for under-floor installation re Joining technique All characteristics defined in the design as referring to joining technique, such as the connections between pipes and ribs, have to be defined in the production drawings and adhered to in production. re Working pressures and pressure tests The permissible working pressure for ribbed tube convectors is at least 4 bar. In case of intermediate values for the pressure levels indicated, the requirements of the respective higher operating pressure are to be observed. Supplementing the test for pressure resistance required by EN sub-section 5.3, the manufacturer has to carry out burst tests. The guideline values for this, with the related warning and intervention limits corresponding to the relevant working pressure are shown in the following table. Complete radiators with a construction length of at least 500 mm are to be used for the burst test. Working pressure Testing pressure Guideline figure Warning limit Intervention limit All figures show pressure over atmospheric pressure in bar If the guideline figure is exceeded by 15% the burst test can be terminated. The number of burst tests required is divided into Stages: Stage 1 Stage 2 Stage 3 1 test after 10 tube registers on each production line, 1 test after 100 tube registers on each production line 1 test on each working day and production line, 1 test at intervals of no more than 5 working days on each production line. Procedure for application Stage 1 is to use when: - new production lines are being started up, - major changes have been made in production lines, - new welding parameters are being calculated for watercarrying connections, e.g. welding or brazing - production is being changed over to a higher pressure level, - readings fall short of the intervention limit. This does not include: changes in construction height or length, model changes, insignificant changes in processing equipment, If the readings do not fall short of the guideline figure after Stage 1, tests can be carried out in accordance with Stage 2. If the readings do not fall short of the guideline figure after 10 consecutive tests in Stage 2, Stage 3 can be applied. If the readings in any test fall short of the guideline figure but not of the warning limit, that Stage should be retained; only when once again 10 consecutive tests have been carried out without falling short of the guideline figure can tests be carried out at the next higher Stage. If the readings in any test fall short of the warning limit, tests must then immediately be conducted according to the next lower Stage. When 10 consecutive tests have been conducted in which the readings did not fall short of the guideline figure, the subsequent tests can be carried out according to the next higher Stage. If the readings fall short of the intervention limit, tests will be carried out according to the necessary measures under Stage 1 with the subsequent test procedure. Action to be taken if readings fall short of the guideline figure Corrective action is necessary if the readings fall short of the guideline figure and the warning limit. They are to be laid down and documented in the Procedural Instructions under the quality assurance system. If the readings fall short of the intervention limit, care should be taken to ensure that a thorough investigation is made that production stops on this production line, and that all radiators produced before and after this sample was taken are not put to any other use until the problem has been completely clarified. Further random samples should be taken and tested if necessary on these radiators. The burst test can be omitted if there is any other way of ensuring that the quality requirements for pressure resistance are being met for the whole radiator, and particularly at the joints with sealing function (weld joints, etc.) by a quality assurance system that meets the above minimum requirements. The auditor has to check the effectiveness of the system. Page 29
31 re 2.5 Coating To ensure a uniform level of quality in the coating a crosscut test should be made every day in accordance with DIN EN ISO 2409 on the surface of a radiator outside the welding spots. No further conditioning of this sample is necessary after the radiator has cooled down to room temperature. The cross-cut reading of Gt 1 should be attained as a minimum. re 3.2 Internal monitoring To ensure a uniform level of quality, the following specification should be met with regard to EN ISO 9001 for quality monitoring. re EN ISO 9001 sub-section 5.6 Management evaluation The user of the quality label must carry out a review and revision of the quality system at least once a year. re EN ISO 9001 sub-section 7.6 Management of monitoring and instrumentation equipment All items of measuring and testing equipment must be subjected to recurrent testing at the following intervals in order to ensure that all readings are accurate and that the equipment is not subject to any decline in accuracy. Manometers (for radiator tests) Micrometers All other measuring, testing, and monitoring instruments Testing normal (e.g.: final dimensions) Every 3 months Every 6 months Every year Every 5 years re EN ISO 9001 sub-section on the verification of bought-in products In the case of bought-in parts that have to withstand pressure, or that are relevant to the function and safety of the radiator, random samples have to be taken of incoming goods at the frequency shown below as a minimum Number of samples per consignment (Stage 0) Up to 5,000 units Up to 20,000 units Over 20,000 units 8 units, 16 units, 20 units. Or corresponding time-dependent determination of the number of random samples which at least meets these requirements. Procedure for defects (acceptance / rejection) If defects are discovered in the samples (acceptance = zero defects, rejection = one defect), a further test has to be carried out. If this also reveals defects, the entire consignment has to be sent back to the supplier or other suitable measures have to be taken to ensure that no defective bought-in parts find their way into production. If consignments are no longer defective, the quality control checks on incoming goods can be reduced in stages: Stage 1: When three consignments have arrived and revealed no defects the test can return to Stage 0 with half the number of units or, at the manufacturer s choice, only every second consignment needs to be checked. Stage 2: When three more consignments have been delivered with no cause for complaint, the test level can be reduced to Stage 0 with one fourth of the number of units or, at the manufacturer s choice, only every fourth consignment needs to be checked. If any consignment within the three Stages is defective, after that the test must start again at Stage 0. These tests on incoming goods can be omitted if there is some other way of verifying that the quality requirements for the bought-in parts are being met by a quality assurance system at the supplier s end that meets the stated minimum requirements. re EN ISO 9001 sub-section on monitoring and measuring the product The following requirements have to be made on the control specifications for production quality control checks unless these have already been covered by the check on incoming goods: Base material: Sheet thickness 2 per batch, min. 2 per shift Sheet width 2 per batch, min. 2 per shift Wall thicknesses 2 per batch min. 2 per shift Dimensions of semi-finished and finished goods: 2 per radiator type (or design), min. 2 per shift. If defects are discovered by production quality checks a further test has to be carried out. If this likewise reveals defects, suitable steps have to be taken to ensure that later products are not affected by any further defects. Page 30
32 Appendix B: Selection of models for testing from model series and families Appendix B 1: Model triangle : Selection of models for testing Convector panel height in mm O Not to be tested X To be tested Construction height in mm Convector panel height in mm O Not to be tested X To be tested Construction height in mm Page 31
33 Convector panel height in mm O Not to be tested X To be tested Construction height in mm Page 32
34 Appendix B 2.1: Model family in the broader sense: Typical example Panel radiator Heating wall Page 33
35 Appendix B 2.2: Model family in the broader sense: Selection of models for testing Panel radiator Construction depth (secondary characteristic dimension) O Not to be tested X To be tested Construction height (primary characteristic dimension) Heating wall Construction depth (secondary characteristic dimension) O Not to be tested X To be tested Construction height (primary characteristic dimension) Page 34
36 Appendix B 3.1: Model family in the narrower sense: Typical example Panel radiator Heating wall Page 35
37 Appendix B 3.2: Model family in the narrower sense: Selection of models for testing Panel radiator Construction depth (secondary characteristic dimension) O Not to be tested X To be tested Construction height (primary characteristic dimension) Heating wall Construction depth (secondary characteristic dimension) O Not to be tested X To be tested Construction height (primary characteristic dimension) Page 36
38 Appendix C: Data sheet for steel radiator DATA SHEET RAL reg. no. Holder of quality label Manufacturing plant Manufacturer s identification Type of radiator: Panel Elements Bathroom Heating wall Convector Other The construction of the radiator corresponds in every detail with the following data and with the attached dimensional sketch. The sketch contains all dimensions necessary for the unambiguous identification of the radiator. Material(s) Coating: Construction with without integral valve fittings (double replies are possible) The heat output data given below apply to the following types of connection: Same side, intake above, return below Alternate sides, intake above, return below connectionns at the bottom opposite end Measures for supplying water: Characteristic data for the tested model series: Construction height 1) Nominal h1, in mm Water content 1) In kg/m or kg/element Empty weight 1) In kg/m or kg/element ΦL 2) In W/m or W/element n 2) 1) Values calculated from test report 2) Values from test report The dimensional sketch (page 2 of the data sheet) contains all data and nominal dimensions relevant to the heat output of the radiator. The dimensions that we established from the radiators that we have tested from this model series / family lie within the permissible limits as defined in EN Table 2. All tolerances for sheet steel thickness that are relevant to output, such as the convector panels, are in accordance with EN The following test reports apply to the calculation of the standard heat output and the exponent(s). Test Report No. Date: Place and date Stamp and signature of test laboratory Page 37
39 Appendix D: Confirmation that the appendix to the obligation note is up to date It is hereby confirmed that the Appendix to the Obligation Note of the firm of Example GmbH & Co, Cologne XY manufacturing plant with the headings 1 to 6 (page 1 dated 00.xx.1995) 7 to 18 (page 2 dated ) Is still fully valid. Date: Name: Signature: Page 38
40 Executive Regulations for the awarding and holding of the quality label for steel radiators 1 Quality basis The basis for the quality label consists of the quality and testing regulations for steel radiators. They are constantly being augmented and further developed in order to adapt them to technical progress. 2 Award 2.1 The Gütegemeinschaft Heizkörper aus Stahl e. V. (the Steel radiators quality association, referred to here for short as the Association ) awards the right to bear its Steel radiator quality label to manufacturers of steel radiators on application. In addition to this the quality label can be awarded to any applicants in respect of radiators that they do not manufacture themselves if they hold at least one RAL certificate from the Association for radiators that they do manufacture themselves. The production locations for the radiators that manufacturers do not produce themselves are treated as an additional production location. 2.2 The application has to be made in writing to the Association s business office in Frankfurter Straße , Cologne and has to be accompanied by the Obligation Note, signed by an authorised signatory (Sample 1), and the documentation listed therein. 2.3 When the Quality Committee has inspected the application documentation for completeness the initial test is carried out on the basis of the application and in accordance with sub-section 3.1 of these Executive Regulations. An independent expert or a testing organisation recognised by the Quality Committee (see Quality and Inspection Regulations, Section 3) inspects the applicant s products in accordance with the Quality and Inspection Regulations. They can inspect the applicant s operational location and request and scrutinise the documentation mentioned in the Quality and Inspection Regulations. If the inspection yields positive results the Quality Committee issues a certificate to the applicant that confirms the conformity of his products to the Quality and Inspection Regulations and gives him the right to use this certificate in accordance with the Association s regulations. The certificate contains the manufacturer s identification number and a table showing all the certified products with their registration numbers. The standard heat output figures as defined in EN 442 are deposited with the Association under these registration numbers. The person entrusted with carrying out the initial test has to show proof of his or her authorisation before starting work. The applicant bears the costs of the tests. 2.4 If the certificate issued by the Quality Committee confirms that the applicant s products conform to the Quality and Inspection Regulations, the Association will award him the quality label. The award is documented (Sample 2). The application submitted to the Quality Committee loses the validity of the attached Obligation Note one year at the latest after it was issued. 3 Use 3.1 Users of the quality label are allowed to use it only for those products that meet the Quality and Inspection Regulations. The allocated registration number is only allowed to be used unambiguously for the model or model series for which certification has been issued. 3.2 The Association is solely entitled to arrange for labelling aides to be produced for the quality label and made available to the user, and also to define in detail the way in which it is to be used. 3.3 The Executive Committee can issue special regulations on the use of the quality label in advertising and in cooperative advertising in order to ensure fairness in competition and prevent any misuse of the label. These regulations will not be allowed to affect the user s individual advertising, which are governed by the same principles of fair competition. 3.4 If the label has been withdrawn with final legal effect the certificate of award and any labelling aids for the quality label have to be returned; the user will have no right to claim any compensation. The same applies if the right to use the label expires for any other reason. 4 Monitoring 4.1 The Quality Committee is entitled and under an obligation to monitor the use of the quality label and adherence to the Quality and Inspection Regulations. The continuity of monitoring has to be substantiated by a monitoring contract with a neutral expert or testing organisation (see Quality and Inspection Regulations, Section 3). 4.2 All users of the quality label must themselves ensure adherence to the Quality and Inspection Regulations. They are under an obligation to maintain a quality assurance system that at least meets the requirements of EN ISO Organisations that were accustomed in the past to using the EN ISO 9002 Standard have to apply this Standard by excluding certain requirements defined in subsection 1.2 of EN ISO They subject those of their products that bear the quality label to monitoring tests by the independent expert who is authorised to make them, or the authorised testing organisation, to the extent and with the frequency that meets the requirements of the Quality and Test Regulations. The users of the quality label bear the costs for all the necessary monitoring inspections under these Executive Regulations. 4.3 Auditors can request or take samples at any time from the label users operating locations. They can also take samples from the distributive trade. If samples are requested they have to be provided without delay. Auditors can inspect label users operating locations at any time during working hours. Page 39
41 4.4 If any test yields a negative result, or if there are grounds for complaint against a product that bears the quality label, the Quality Committee can require the test to be repeated. The label user can likewise request the test to be repeated. 4.5 An audit report has to be issued on every test. The inspected firm and the Quality Committee each receive one copy of this report. 4.6 If complaints are raised against products that bear the quality label and later prove to be unfounded, the complainant bears the cost of the inspection; if the complaint is found to be justified, the label user in question bears the cost. 5 Penalties for violations 5.1 If the Quality Committee discovers defects in the quality assessment system it will initiate the following measures in accordance with the information stated: Additional requirements in connection with internal monitoring These can be required as part of the measures for eliminating defects under sub-section of the Quality and Inspection Regulations Increases in external monitoring Additional external monitoring inspections can be required if there is a special reason for them, e.g. serious irregularities in the quality level of the product or in the quality assurance system Warning with period of notice Warnings can be issued against users of the quality label who violate the provisions of Section 3 or 4 above. If the user of the quality label has been definitely shown to be in violation, the Quality Committee will set a period of time in which he has to rectify the deviations. Generally speaking this period of time will not exceed three months. The warning with period of notice can be combined under certain circumstances with increased external monitoring Suspension of the validity of the certificate of conformity temporary withdrawal of the quality label. If the warning with period of notice in connection with deviations as described in sub-clause does not produce the desired result, the Quality Committee can suspend the validity of the certificate it has issued. In serious cases it can suspend validity immediately and without prior warning. The same also applies if safety, health, or the environment is endangered. This also applies if users of the quality label repeatedly violate Section 3 or 4 or if they delay or impede the tests. When the period of time has elapsed for which the conformity certification had been suspended, a monitoring test is carried out to establish whether the conditions required by the Quality and Inspection Regulations are being met. If they are being met, the quality label user has to be informed that his conformity certification is now valid again. The Association s Executive Committee takes every suspension of the validity of the conformity certification as grounds for temporarily withdrawing the quality label. The quality label approval can also be temporarily withdrawn for the period of time of an interruption to production for any similar reason if this has been agreed by the Association s Executive Committee and the user of the quality label. The Association s Executive Committee has to state the conditions under which the temporary withdrawal will be terminated Cancellation of conformity certification duration of withdrawal of label The Quality Committee is only allowed to cancel a conformity certification if the preceding measures described in sub-sections to with regard to the established deviations prove ineffective, or with immediate effect in serious cases. If the check test that is carried out after the expiry of the period of time for the suspension of the conformity certification under the provisions of sub-section fails to substantiate that the required conditions are being met, the Quality Committee can cancel the conformity certification. The Association s Executive Committee can take every cancellation of the conformity certification as grounds for permanently withdrawing the quality label. The Association s Executive Committee will withdraw the quality label permanently if the user informs it that he no longer needs the quality label. In urgent cases the Chairman of the Association can temporarily withdraw the quality label with immediate effect. This action requires confirmation by the Association s Executive Committee within 14 days. 5.2 The user of the quality label will be informed of these measures by means of a registered letter from the Association. In the case of a temporary withdrawal the letter will also state the duration of the withdrawal. 5.3 In the case of a temporary or permanent withdrawal of the quality label as described in sub-sections and 5.1.5, the Association s Executive Committee can require the user of the quality label to remove the quality label from the products concerned. In the case of a temporary or permanent withdrawal of the quality label the Association s Executive Committee will decide whether stocks of goods that bear the quality label can be used up or whether the quality label is to be removed from these products. 5.4 The user concerned is to be given a hearing in connection with any of these measures. 5.5 The penalty measures described in sub-sections 5.1 to 5.3 take effect as soon as they legally come into force. 6 Appeals Quality label users can raise an appeal against notices of penalty within 4 weeks of receiving them. The appeal has to be submitted in writing by registered mail. Page 40
42 7 Re-awards 8 Changes If the right to use the quality label has been withdrawn, it cannot be re-awarded until a further period of at least three months has passed. The procedure will follow that described in Section 2. The Association s Executive Committee can impose additional conditions. These Executive Regulations for the awarding and use of the quality label and the appendices (Obligation Note and Certificate of Award) are accepted by RAL. No changes, including improvements to the wording, have any validity unless RAL has given its prior written consent. They take effect an appropriate length of time after the RAL Management Board has informed of them. Page 41
43 Sample 1 to the executive regulations OBLIGATION NOTE 1. The undersigned person / company hereby applies to the Gütegemeinschaft Heizkörper aus Stahl e.v.: to be accepted as a member to be awarded the right to bear the quality label for the steel radiators listed in the following table. The table contains pages 2. The undersigned person / company hereby confirms that he/she/it has taken due note of the following: - the Statutes of the Gütegemeinschaft Heizkörper aus Stahl e.v. - the Statutes applicable to the quality label - the Quality and Inspection Regulations for steel radiators - the Executive Regulations and hereby accepts them without reservation as having binding effect. (Place and date) (Stamp and signature) Each page of this Appendix to the Obligation Note must be signed by a legally authorised signatory and the name of the signatory must also be shown in block letters. The copy of the test reports and all other documentation necessary for substantiating conformity to the Standards as required by sub-section of the Quality and Inspection Regulations must be attached for all the radiator models listed in the table. Page 42
44 Appendix to sample 1 to the executive regulations Appendix to the obligation note List of registrations Page 1 of 1 Company Manufacturing plant GZ Reg. no. Process Date Type *) Description Registration list drawn up on: *) A = Application; C = Certification; U = Conversion It is hereby confirmed that the above registration lists are valid Date Signature... Name in block letters Page 43
45 Sample 2 to the executive regulations Certificate of Award The Gütegemeinschaft Heizkörper aus Stahl e.v. (the Steel Radiator Quality Association ) hereby awards, on the basis of the certification submitted to its Quality Committee, to the firm of the Steel Radiators Quality Label recognised by the RAL Deutsches Institut für Gütesicherung und Kennzeichnung e.v. (German Institute for Quality Assurance and Labelling) and protected by an entry at the German Patents and Trademarks Office as a Collective Mark. Authorisation to label products with the quality label applies to all the models / model series stated in the currently valid Registration of quality-tested steel radiators Issued in Cologne on: Gütegemeinschaft Heizkörper aus Stahl e.v President Chairman of the Quality Committee Page 44
46 HISTORY In 1925, the German private sector and the German government at that time founded the Reichs- Ausschuß für Lieferbedingungen (RAL). The common aim was to standardise and specify technical delivery conditions. Established quality requirements and their control were needed for this purpose the quality assurance system emerged. Creation of a neutral institution as a self-administration body for all those involved in the market was required for its implementation. This was the hour of birth of RAL. Since that time, RAL has had the competence for creation of quality labels. RAL TODAY RAL operates as an independent service provider with its fields of activity. RAL is recognised as a nonprofit-making institution and has the legal form of a registered association. Its organs are the chairmanship, board of trustees, the general meeting and the management. As an expression of its independence and impartiality, the guidelines for the RAL s activities are determined by the board of trustees formed of representatives of leading organisations from the economy, consumers, agriculture, federal ministries and other federal organisations. They have a permanent seat and vote in this committee, to which a further four quality associations are co-opted by the general meeting as representatives of the RAL members. RAL COMPETENCE FIELDS RAL creates quality labels RAL issues internationally binding colour guidelines RAL awards the Blue Angel environmental label and the European environmental label RAL creates registrations, agreements and RAL attestations RAL DEUTSCHES INSTITUT FÜR GÜTESICHERUNG UND KENNZEICHNUNG E.V. Siegburger Straße 39, Sankt Augustin, Tel.: +49 (0) , Fax: +49 (0) [email protected] Internet: Page 45
JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes
JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes 1. Scope This Japanese Industrial Standard specifies the electric resistance welded carbon steel tubes, hereinafter
Metal Pressfitting Pipe Systems
VdS Guidelines for water extinguishing systems VdS 2100-26-3en Requirements and test methods Part 3: Additional provisions for Pipe Systems made of galvanized steel VdS 2100-26-3en : 2012-04 (01) Publishing
GK Packing System Welding Instructions
GK Packing System Welding Instructions Roxtec GmbH Neuer Höltigbaum 1-3, 22143 Hamburg GERMANY Tel +49 (040) 657398-0, Fax +49 (040) 657398-50 EMAIL [email protected], www.roxtec.de Welding instructions
Guidelines for the Acceptance of Manufacturer's Quality Assurance Systems for Welding Consumables
(1987) Guidelines for the Acceptance of Manufacturer's Quality Assurance Systems for Welding Consumables 1. General 1.1 Introduction 1.1.1 The present guidelines are to serve as a supplement to the IACS
Guiding Principles for the contents of Particular Materials Appraisals (Version approved at the WGP on 21 November 2006)
PE- 03-28 - rev 5 21 November 2006 Page 1 of 5 Guiding Principles for the contents of Particular Materials Appraisals (Version approved at the WGP on 21 November 2006) Introduction A Particular Material
Quality Regulations for Profiles
Quality Regulations for Profiles September 2010 Quality Regulations for Profiles Page 2/42 Contents Preface... 4 1. Terms and Definitions... 5 1.1 Third parties... 5 1.2 Independent laboratories... 5 1.3
Length measuring instruments
INTERNATIONAL OIML R 66 RECOMMENDATION Edition 1985 (E) Length measuring instruments Instruments mesureurs de longueurs OIML R 66 Edition 1985 (E) ORGANISATION INTERNATIONALE DE MÉTROLOGIE LÉGALE INTERNATIONAL
ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013
ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 0 QUALITY 0 YEAR GUARANTEE Exclusively distributed by: Table of contents Panel radiators General / Guarantee Technical data and radiator dimensions
Planning Information. Passenger and Freight Elevators.
A company of ThyssenKrupp Elevator Thyssen Aufzüge tk This planning information will give you an overview of the most important planning criteria of passenger and freight elevators. However you should
Measuring instruments in industry.
Measuring instruments in industry. Measuring instruments that are present in any branch of industry, are subject to different levels of supervision, like in case of laboratories. Supervision relates to
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...
Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information
Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes
Naue GmbH&Co.KG Quality Control and Quality Assurance Manual For Geomembranes July 2004 V.O TABLE OF CONTENTS 1. Introduction 2. Quality Assurance and Control 2.1 General 2.2 Quality management acc. to
Mountaineering and Climbing Equipment CONNECTORS / KARABINERS. Foreword
Mountaineering and Climbing Equipment CONNECTORS / KARABINERS UIAA 121 Foreword This UIAA Standard is only published in the English language version, which is the master text. For any validations in translation,
COATING & WRAPPING OF UNDERGROUND PIPING
CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification
FINAL DRAFT PREN ISO 14327 RESISTANCE WELDING PROCEDURES FOR DETERMINING THE WELDABILITY LOBE FOR RESISTANCE SPOT, PROJECTION AND SEAM
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG CEN/TC 121 N 1060 FINAL DRAFT PREN ISO 14327 RESISTANCE WELDING PROCEDURES FOR DETERMINING THE WELDABILITY
IMQ RULES. Contents. IMQ Rules - Product certification
IMQ RULES PRODUCT CERTIFICATION "ELECTRIC ENERGY METERS AND METER UNITS" PRODUCT OF NEW MANUFACTURING Contents IMQ Rules - Product certification Particular Rules for the Electric energy meters and meter
VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
Test Report No. C829QPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Westech Components Wuxi Co.,
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES Interpretations of the FTP CONTENTS FTP1 Adhesives used in A or B class divisions (FTP Code 3.1, Res A.754 para. 3.2.3) June 2000 FTP2 Pipe and duct
CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS
CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS 1.0 DESIGN 1.1 Scope of Work 1.1.1 This work shall consist of furnishing Isolation Bearings and installing Isolation Bearing Assemblies at the locations
Fixed Access Ladders. Table of Contents. 1. Legislative Requirements
Fixed Access Ladders Engineering Data Sheet 2-04 Revised: January 1997 Table of Contents 1. Legislative Requirements 2. General 3. Rungs 4. Side Rails 5. Safety Cages 6. Attachment & Anchoring 7. Platforms
Field Welding Inspection Guide
Field Welding Inspection Guide Assistance in interpretation of any specification or questions concerning field welding issues can be obtained from the Office of Materials Management, Structural Welding
European Technical Assessment ETA-10/0153 of 10/06/2015
ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet ww.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011 of
General Commercial Terms and Conditions
Valid and effective from 4.6.2016 Page 1 of 5 General Commercial Terms and Conditions of realization of supplies and withdrawal of products and services (hereinafter referred to as the GCTC ) supplied
American Society of Agricultural and Biological Engineers
ASAE S580.1 NOV2013 Testing and Reporting Solar Cooker Performance American Society of Agricultural and Biological Engineers ASABE is a professional and technical organization, of members worldwide, who
Copies of this document shall be classified either as Controlled or Uncontrolled, and shall be identified as such on the cover sheet.
INTRODUCTION This document describes an inspection system broken down into four separate levels. When Inspection Level IV is invoked, this system meets the requirements of former MIL-I-45208A. The primary
Supplier Requirements Manual M M 0 3
Supplier Requirements Manual M M 0 3 Conformance to this manual is a requirement for all of Merrill Technologies Group and Ranger s suppliers & subcontractors, unless otherwise specified on purchase orders.
NORSOK STANDARD M-650 Edition 4. Qualification of manufacturers of special materials
Date: 2014-05-30 NORSOK STANDARD M-650 Edition 4 Qualification of manufacturers of special materials A: Frequently Asked Questions FAQ B: Clarification and Comment List NORSOK standard M650 Ed. 4 INTRODUCTION
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Application of Welding Standards in Hong Kong. S. K. Babu Laboratory Manager - Foundation Techniques Ltd
Application of Welding Standards in Hong Kong S. K. Babu Laboratory Manager - Foundation Techniques Ltd Introduction: This paper summarizes the current welding standards practiced in Hong Kong & also outlines
VdS Guidelines for the Certification of quality management systems
VdS Guidelines for the Certification of quality management systems VdS 2343en : 2015-09 (11) VdS 2343en : 2015-09 (11) Certification of quality management systems VdS Guidelines VdS Guidelines for the
Technical catalogue panel radiators POLAND 2014
Technical catalogue panel radiators POLAND 2014 2 table of contents panel radiators overview...4 panel radiators overview... 88 Compact... 10 Ventil Compact 200 mm... 91 Ventil Compact... 16 Plan Ventil
Tube Control Measurement, Sorting Modular System for Glass Tube
Tube Control Measurement, Sorting Modular System for Glass Tube Tube Control is a modular designed system of settled instruments and modules. It comprises measuring instruments for the tube dimensions,
JIS G3445 Carbon steel tubes for machine structural purposes
JIS G3445 arbon steel tubes for machine structural purposes 1. Scope This Japanese Industrial Standard specifies the carbon steel tubes, hereinafter referred to as the "tubes", used for machinery, automobiles,
DVC Product Certification - affiliated to the Danish Technological Institute
PROD Reg. No. 7002 DVC Product Certification DVC Product Certification - affiliated to the Danish Technological Institute Requirements concerning Certification of Products and their Compliance with the
39HQ Airovision Air Handling Units
39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport
NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE
B4 NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE AVAILABLE IN CARBON AND STAINLESS STEEL 23 THEORY
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use
Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.
Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports. Report number C 1395-1E-RA-003 d.d. May 14, 2014 Fire-resistant barriers: background on requirements
Thermal Mass Availability for Cooling Data Centers during Power Shutdown
2010 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Published in ASHRAE Transactions (2010, vol 116, part 2). For personal use only. Additional reproduction,
Non-destructive testing of steel forgings - Part 2: Penetrant testing (BS EN 10228-2:1998)
Non-destructive testing of steel forgings - Part 2: Penetrant testing (BS EN 10228-2:1998) 1 Scope This part of EN 10228 describes the method and acceptance criteria to be used for the penetrant testing
Specification for Rotary Drill Stem Elements
Addendum 1 March 2007 Effective Date: September 1, 2007 Specification for Rotary Drill Stem Elements ANSI/API SPECIFICATION 7-1 FIRST EDITION, MARCH 2006 EFFECTIVE DATE: SEPTEMBER 2006 ISO 10424-1:2004
ROLLED STAINLESS STEEL PLATES, SECTIONS AND BARS
STANDARD FOR CERTIFICATION No. 2.9 ROLLED STAINLESS STEEL PLATES, SECTIONS AND BARS OCTOBER 2008 Veritasveien 1, NO-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD (DNV) is an autonomous
NATIONAL ASSESSMENT GUIDELINE FOR THE KOMO PROCESS CERTIFICATE FOR THE INSTALLATION OF FACADE CLADDING USING ADHESIVE SYSTEMS
BRL 4104 01-02-2003 NATIONAL ASSESSMENT GUIDELINE FOR THE KOMO PROCESS CERTIFICATE FOR THE INSTALLATION OF FACADE CLADDING USING ADHESIVE SYSTEMS Accepted by the Harmonisatie Commissie Bouw of the Stichting
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Medical Compression Armsleeves
GÜTEZEICHEN MEDIZINISCHE KOMPRESSIONS- STRÜMPFE Medical Compression Armsleeves Quality Assurance RAL-GZ 387/2 Edition January 2008 DEUTSCHES INSTITUT FÜR GÜTESICHERUNG UND KENNZEICHNUNG E. V. Publisher:
Building Diagnostic Tests as Assessment Tools 診 斷 樓 宇 狀 況 的 測 試 : 樓 宇 檢 驗 的 評 估 工 具
Building Diagnostic Tests as Assessment Tools 診 斷 樓 宇 狀 況 的 測 試 : 樓 宇 檢 驗 的 評 估 工 具 presented by Ir Samson K.Y. WONG Senior Accreditation Officer, Hong Kong Accreditation Service, Innovation and Technology
Quality Management System Manual ISO9001:2008
Quality Management System Manual ISO9001:2008 Controlled Copy Rev. 3 Page 1 of 21 7/1/13 Table of Contents Company Profile...5 Past...5 Present...5 Mission...5 Vision...5 Locations...6 1 Scope...6 1.1
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
Butt Fusion Welding of HDPE Pipes Work Procedure
Butt Fusion Welding of HDPE Pipes Work Procedure A pipeline is as good as its weakest point. Accordingly it is not only important that quality pipes and components are used in a piping system, but also
CONSUMER PROTECTION LAW OF MONGOLIA. 24 June, 1991 Ulaanbaatar. Chapter One. General Provisions
CONSUMER PROTECTION LAW OF MONGOLIA 24 June, 1991 Ulaanbaatar Chapter One Article 1. Purpose of the Law General Provisions 1. The purpose of this law is to regulate relations connected with protection
Safety Storage Cabinets
Safety Storage Cabinets Safe storage of flammables? The workplace without a fire resistant Safety Storage Cabinet Dangers, risks and your disadvantages... STORAGE ROOM Transport/working time - Increased
TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)
TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) 1. Requirement: Two (02) Nos. DC Type, 3 phase, 3 wire Projection Welding Machine is required for welding of ventilation M.S. / Stainless
The Effect of Forced Air Cooling on Heat Sink Thermal Ratings
zpero 1 The Effect of Forced Air Cooling on Heat Sink Thermal Ratings By Paul Bachman, Fellow Engineer & Ronnie Haiduk, Applications Engineer, Crydom, Inc. ABSTRACT A heat sink s ability to dissipate thermal
CONFORMITY MARKINGING FOR THE GCC COUNTRIES. Issue No.: (5) Date: (2/21/2008) Committee Draft No. 5
The Gulf Cooperation CONFORMITY MARKINGING FOR THE GCC COUNTRIES Committee Draft No. 5 Hint This Translation is informative and is not binding. List of Issue No.: (5) 1/9 Contents Clause 1: Purpose 3 Clause
English Version. Fire safety storage cabinets - Part 2: Safety cabinets for pressurised gas cylinders
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM EN 14470-2 August 2006 ICS 13.220.40; 71.040.10 English Version Fire safety storage cabinets - Part 2: Safety cabinets for pressurised gas cylinders
Federal Institute for Materials Research and Testing (BAM) Pyrotechnics Division 2.3 Explosives D -12200 Berlin Berlin, 2013-12-10
Federal Institute for Materials Research and Testing (BAM) Pyrotechnics Division 2.3 Explosives D -12200 Berlin Berlin, 2013-12-10 Pyrotechnic Articles Directive 2007/23/EC Information on the Conformity
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General
ENGLISH FORK GUIDE 2013
FORK GUIDE 2013 ENGLISH 1 With a brand which is synonymous with specialists in forest products handling attachments, BOLZONI AURAMO offers its expertise and market leading attachments for all requirements,
ASTM A860/A860M-09 Standard Specification for Wrought High Strength. Ferritic Steel Butt Welding Fittings. 1. Scope :- 2. Reference Documents :-
Standard Specification for Wrought High Strength Ferritic Steel Butt Welding Fittings 1. Scope :- 1.1 This specification covers wrought high strength ferritic steel butt-welding fitting of seamless and
SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents
English translation of German original Technical Information TI-P11 SITEMA PowerStroke Mould Closing Devices series FS drive system for powerful forces on a short stroke hydraulic actuation closing force
Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts. www.tyco-fire.com
Worldwide Contacts www.tyco-fire.com Model EC-HS 80 K-factor, Quick Response Extended Coverage Horizontal Sidewall Sprinklers Installations per VdS CEA 400, Annex E, LH/OH General Description The Model
IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality
IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION Generated: Sergiy Papyshev Engineering Approved: Don Prysi Manufacturing Approved: Merzuk Ramic Quality Approved: Steven Barnett Administrative DATE DATE DATE
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
Window Glass Design 5 According to ASTM E 1300
A User s Guide to: Window Glass Design 5 According to ASTM E 1300 A product of: 1 Table of Contents Table of Contents List of Figures Chapter 1: Window Glass Design 5 1.1 Introduction 1.2 Features ii iv
The Pipelines Regulations, 2000
PIPELINES, 2000 P-12.1 REG 1 1 The Pipelines Regulations, 2000 being Chapter P-12.1 Reg 1 (effective April 1, 2000) as amended by the Statutes of Saskatchewan, 2014, c.21. NOTE: This consolidation is not
How To Build A Brugman Compact Radiator
THE ESSENCE TECHNICAL DOCUMENT 2010 OF WARMTH horizontal Standard compact 4 universal compact vertical Verti M Standard Verti M Compact horizontal piano universal compact vertical Verti M Piano mini piano
1.1.2 Polypropylene The polypropylene must be a white opaque film, 1 2 mil thick. Biaxial orientation is preferred.
Library of Congress Preservation Directorate Specification Number 700 704 09 Specifications for Pressure Sensitive Adhesive Labels For Application to Single Paper Sheets and Text Pages of Bound Books For
TARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
UGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
Implementing Regulations under the Benelux Convention on Intellectual Property (Trademarks and Designs) *
Implementing Regulations under the Benelux Convention on Intellectual Property (Trademarks and Designs) * The Executive Board of the Benelux Trademark Office and the Executive Board of the Benelux Designs
Calvert USA, Inc. Attic Stairs
Calvert USA, Inc. Attic Stairs Instructions for installation of vertical opening access stairs Model numbers: 7035 through 7047 Calvert USA, Inc., P.O. Box 841, Solomons, MD 20688, Tel. (410) 286-1430,
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A
Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as
REGULATION (EEC) No 2309/93
REGULATION (EEC) No 2309/93 Council Regulation (EEC) No 2309/93 of 22 July 1993 laying down Community procedures for the authorization and supervision of medicinal products for human and veterinary use
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
James M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
Tubular solutions for the Solar Power Industry Rise in success with precision
Tubular solutions for the Solar Power Industry Rise in success with precision A comprehensive offer Precision tubes designed for CSP industry applications Solar collectors q Tubes adapted for solar heat
Rules for Classification and Construction Materials and Welding
II Rules for Classification and Construction Materials and Welding 3 Welding 1 General Requirements, Proof of Qualifications, Approvals Edition 2000 The following Rules come into force on July 1 st, 2000
PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany
ABSTRACT: PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany Today, in-line inspection tools are used routinely
CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:
Two most common lock nut groups: 1. PREVAILING TORQUE a design feature of the lock nut produces friction between threads of mated components thereby increasing the force needed to tighten as well as loosen
INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS. Published: April 1999
INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS Published: April 1999 CONTENTS 1 Introduction 2 Test Procedures General 3 Standards and Specific Test Procedures
a) To achieve an effective Quality Assurance System complying with International Standard ISO9001 (Quality Systems).
FAT MEDIA QUALITY ASSURANCE STATEMENT NOTE 1: This is a CONTROLLED Document as are all quality system files on this server. Any documents appearing in paper form are not controlled and should be checked
SECTION 15410 GROUND WATER STORAGE TANKS
SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design
Tolerance Charts. Dr. Pulak M. Pandey. http://paniit.iitd.ac.in/~pmpandey
Tolerance Charts Dr. Pulak M. Pandey http://paniit.iitd.ac.in/~pmpandey Introduction A tolerance chart is a graphical method for presenting the manufacturing dimensions of a workpiece or assembly at all
The certification process
TS004(COS)v01 The certification process for COSMOS standard Standard in force available on www.cosmos-standard.org or sent on request. 1 Contents I. When to apply... 3 II. The different steps in the certification
AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels
AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels AISI No. 1008 1010 1012 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 10 1026 1027 1029 10 1035 1036 1037 1038 1039 10 1041 1042 1043
Check-list for auditors. Audit visit at candidate registered laboratories
Check-list for auditors Audit visit at candidate registered laboratories 1 Contents Introduction Laboratory documentation required by the standard(s), available for inspection by the auditor Items to be
Certificate: 0000038506_01 / 29 April 2014
Test report: 936/21219899/C of 30 August 2013 Initial certification: 23 July 2013 Expiry date: 22 July 2018 Publication: BAnz AT 01 April 2014 B12, chapter II, No. 1.1 Approved application The tested AMS
Danish Window Certification - affiliated to the Danish Technological Institute
PROD Reg. No. 7002 Danish Window Certification Danish Window Certification - affiliated to the Danish Technological Institute Requirements concerning certification of window and door products and their
General Rules for the certification of Management Systems
General Rules for the certification of Management Systems Effective from 19/11/2015 RINA Via Corsica 12 16128 Genova - Italy tel. +39 010 53851 fax +39 010 5351000 website : www.rina.org Technical rules
PivotLoc Ladder Systems
N25 ACCESS AND SAFETY EQUIPMENT SPECIFICATION CLAUSES PivotLoc Ladder Systems To be read with The Main Contract Preliminaries, General Conditions, Sub-Contract Preliminaries. MINIMUM CONTRACTOR STANDARD
Steel procurement in major projects: Guidance on the application of social issues. Purpose
Steel procurement in major projects: Guidance on the application of social issues Purpose 1. This is a practical guide on how to incorporate social issues in major projects with a significant steel component.
SERVER ROOM CABINET INSTALLATION CONCEPTS
SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the
INSTALLATION. General. Important Note. Design. Transport
General The roof trusses you are about to install have been manufactured to precise engineering standards. To ensure that the trusses perform as designed, it is essential that they be handled, erected
Technical catalogue convectors POLAND 2012
Technical catalogue convectors POLAND 2012 index convectors review...3 Narbonne...4 Narbonne VT... 10 Narbonne V... 16 Narbonne V VT... 20 mounting distances for Narbonne...26 mounting distances for Narbonne
Good Manufacturing Practices for the Production of Packaging Inks formulated for use on the non food contact surfaces of food packaging and articles
Good Manufacturing Practices for the Production of Packaging Inks formulated for use on the non food contact surfaces of food packaging and articles intended to come into contact with food October 2005
Measuring equipment in a laboratory.
Measuring equipment in a laboratory. Laboratory and metrology are two words that practically do not function separately. They are integrally connected to measuring equipment for tests and measurements.