HAREDA PROCEDURE FOR MANDATORY INSTALLATION OF SOLAR WATER HEATING SYSTEMS IN HARYANA
|
|
|
- Steven Preston
- 9 years ago
- Views:
Transcription
1 HAREDA PROCEDURE FOR MANDATORY INSTALLATION OF SOLAR WATER HEATING SYSTEMS IN HARYANA Haryana Renewable Energy Development Agency (HAREDA) (Department of Renewable Energy, Haryana) SCO-48, Sector-26, Chandigarh Tel: , Fax: website- 1
2 INTROUCTION TO SOLAR WATER HEATING SYSTEM Haryana is blessed with Solar Energy in abundance at no cost. The solar radiation incident on the surface of the earth can be conveniently utilized for the benefit of human society. One of the popular devices that harnesses the solar energy is solar water heating system (SWHS). Solar Water Heating is a Renewable Technology which can be used to meet the hot requirement in domestic, Commercial and Industrial Sector. A solar water heater consists of a collector to collect solar energy and an insulated storage tank to store hot water. The solar energy incident on the absorber panel coated with selected coating transfers the heat to the riser pipes fitted underneath the absorber panel. The water passing through the riser get heated up and is delivered to the storage tank. The re-circulation of the same water through absorber panel in the collector raises the temperature to 80º C (Maximum) in a good sunny day. The total system with solar collector, storage tank and pipelines is called solar hot water system. Broadly, the solar water heating systems are of two categories. They are: closed loop system and open loop system. In the first one, heat exchangers are installed to protect the system from hard water obtained from bore wells or from freezing temperatures in the cold region. In the other type, either thermosyphen or forced circulation system, the water in the system is open to the atmosphere at one point or other. The thermosyphen systems are simple and relatively inexpensive. They are suitable for domestic and small institutional systems, provided the water is treated and potable in quality. The forced circulation systems employ electrical pumps to circulate the water through collectors and storage tanks. The choice of system depends on heat requirement, weather conditions, heat transfer fluid quality, space availability, annual; solar radiation, etc. The SHW systems are economical, pollution free and easy for operation in warm countries like outs. Based on the collector system, solar water heaters can be of two types. Flat Plate Collectors (FPC) based Solar Water Heaters (SWH) The Solar radiation is absorbed by Flat Plate Collectors which consists of an insulated outer metallic box covered on the top with glass sheet. Inside there are blackened metallic absorber (selectively coated) sheets with built in channels or riser tubes to carry water. The absorber absorbs the solar radiation and transfers the heat to the flowing water. There are 83 BIS approved manufacturers of Solar Flat Plate Collectors. Evacuated Tube Collectors (ETC) based Solar Water Heaters (SWH) Evacuated Tube Collector is made of double layer borosilicate glass tubes evacuated for providing insulation. The outer wall of the inner tube is coated with selective absorbing material. This helps absorption of solar radiation and transfers the heat to the water which flows through the inner tube. The MNRE, GOI approve 2
3 ETC based solar water heating system. However, this being a new technology, it is advised that before installing the ETC based system, the buyer should ensure proper specification and test reports of the system issued by the Ministry of New and Renewable Energy, Govt. of India. Solar water heating is now a mature technology. Wide spread utilization of solar water heater scan reduce a significant portion of the conventional energy being used for heating water in homes, factories and other commercial and institutional establishments. Internationally the market for solar water heaters has expanded significantly during the last decade. Salient Features of Solar Water Heating Systems Solar Hot Water system turns could water into hot water with the help of sun s rays. Around 60 deg. 80 deg. C temperature can be attained depending on solar radiation, weather conditions and solar collector system efficiency Hot water for homes, hostels, hotels, hospitals, restaurants, dairies, industries etc. Can be installed on roof-tops, building terrace and open ground where there is no shading, south orientation of collectors and over-head tank above SWH system SWH system generates hot water on clear sunny days (Maximum), partially clouded (moderate) but not in rainy or heavy overcast day Only soft and potable water can be used Stainless Steel is used for small tanks whereas Mild Steel tanks with anticorrosion coating inside are used for large tanks Solar water heaters (SWHs) of litres capacity are suited for domestic application. Larger systems can be used in restaurants, guesthouses, hotels, hospitals, industries etc. Space Requirement Approx. 3 sq. meter shadow free South facing space is required for 100 lpd system having one collector. Fuel Savings: Depending upon the fuel replaced, the annual savings by a 100 LPD solar water heater are as under: Fuel Calorific Value Efficiency (%) Fuel Saved ( K Cal/Kg) (KG/Annum) Firewood Kerosene LPG Charcoal Diesel Electricity (KWH) Avoided utility cost on generation: 3
4 The use of 1000 nos. of Solar water heating systems of 100 litres capacity each, can contribute to a peak load shaving of 1 MW, assuming that 50% of the Electrical Geysers, each of 2 KW capacity are in use during peak hours. Environmental benefits: A SWH of 100 litres capacity can prevent emission of 1.5. Tonnes of carbondioxide per year. Life: years Approximate cost: Around Rs for a 100 litres capacity SWH Rs per installed litre for higher capacity systems Payback period: 2-3 years when electricity is replaced 4-5 years when furnace oil is replaced 6-7 years when coal is replaced Though the initial investment for a solar water heater is high compared to available conventional alternatives, the return on investment has become increasingly attractive with the increase in prices of conventional energy. The pay back period depends on the site of installation, utilization pattern and fuel replaced. ESTIMATES OF REQUIREMENT OF HOT WAT ER SOME USEFUL THUMB RULES Application Typical Requirement of Hot Water at 60 C Household bathing using buckets liters per person per bath Household bathing using shower Litres for 10 Minute bath Shaving, while a tap runs Litres Household bathing in bathtub ( one filling) Litres Wash basin (hand wash, brushing of teeth, etc.) 3-5 Litres per person per day Kitchen washing 2-3 Litres per person per day Dish washer Litres per washer cycle Clothes washing machine Litres per Wash cycle Industrial Canteen 3-5 Litres per worker per day Small unstarred hotels litres per occupant per day Starred hotels Litres per room per day Hospitals Litres per bed per day Multistoried apartments: (revised on ) Number of stories Flat Size New Capacity Norms of SWHS per Flat G+4 2 BHK 100 lpd 3 BHK and above lpd G+5 to G+9 2 BHK lpd 3 BHK and above lpd G+10 to G+14 2 BHK lpd 3 BHK and above 75 to 100 lpd G+15 to G+20 & above 2 BHK 35 to 50 lpd 3 BHK and above 35 to 75 lpd Note : All the estimates are given for hot water at 60º C. This hot water has to be mixed with cold water to bring down its temperature to endurance limits. Mixing will also increase quantity of hot water actually required. 4
5 MANDATORY USE OF SOLAR WATER HEATING SYSTEMS Vide Haryana Government Gazette Notification No.22/52/2005-5P dated 29/7/05, the use of solar water heating systems has been made mandatory in industries where hot water is required for processing, hospitals and Nursing Homes, Govt. Hospitals, Hotels, Motels and Banquet Halls, Jail barracks, Canteens, Housing Complexes set up by Group Housing Societies/Housing Boards, all Residential buildings built on a plot of size 500 sq.yds. and above falling within the limits of Municipal Committees/Corporations and HUDA Sectors, all Govt. buildings, Residential Schools, Educational Colleges, Hostels, Technical/Educational Institutes, District Institute of Education and Training, Tourism Complexes and Universities etc. HAREDA has been declared as an approved sources for supply and installation of solar water heating systems in the State to ensure installation of optimally designed quality systems as per the specifications. In order to streamline the installation of Solar Water Heating Systems in the State, following procedure has been laid: PROCEDURE FOR MANDATORY INSTALLATION OF SOLAR WATER HEATING SYSTEMS 1. Application: The applicant will be required to apply in the prescribed format for capacity approval / approval of provision of Solar Water Heating Systems in the buildings (for new building at the time of start of construction of the building). The application must be accompanied by approved drawing of the building which clearly shows terrace plan of buildings. The format would includes, name of the building, architect, occupancy. No. of toilets, kitchens, covered area and area available in the terrace for installation of SWHS. For domestic systems and systems up to 1000 lpd capacity the application should be submitted to the ADC-cum-CPO (IREP) office of the concerned district. For non-domestic, Group Housing, industrial and commercial categories, systems of capacity more than 1000 lpd capacity the application should be submitted to the Director, HAREDA, SCO No.-48,Sector- 26,Chandigarh.. The ADC Office/HAREDA may call for any additional information if required for assessment of hot water requirement of the proposed building. 2. Fee The applicant will be required, to pay non-refundable processing fee of Rs. 50/- per square meter of the collector area of the system in the shape of a Demand Draft in favour of Director, HAREDA payable at Chandigarh along with the application. 3. Assessment of hot water required: Within one month from the date of receipt of application, the site will be inspected by the Project Officer/ APO of the concerned district/hareda for the assessment of hot water requirement of the Project. Based on the assessment of hot water, a letter for making provision of recommended capacity of Solar Water Heating System for the proposed building will be issued. The ADC offices shall issue the letter for accordingly approval on 5
6 the capacity of the systems to be taken up for installation of capacities upto 1000 LPD. While for capacities more than 1000 LPD, the letter recommending the capacity of SWHS in the proposed building will be issued by the Director, HAREDA. 4. Minimum Technical Specification The system to be installed must be comply with minimum technical requirement of MNRE/HAREDA for FPC & ETC Based Solar Water Heating System attached at Annexure-I & II. Further, the applicant also takes declaration from manufacturer that his system comply with latest minimum technical requirement as mentioned above. 5. Supervision of Installation: The applicant will be required to intimate the ADC office/hareda about the start of installation of Solar Water Heating System. The site will be inspected by the PO/APO during the installation phase to check the quality and capacity of the system. 6. Issuance of NOC Once the Solar Water Heating System has been installed, the applicant will be required to apply for issue of NOC in the prescribed format. The application must be accomplished by requisite document viz. capacity approval letter from HAREDA/PO of the concern districts, allotment letter from HUDA/MC, Registration Certificates, Supplier BIS/MNRE Approved Test Certificate, Joint Commissioning Report, SWHS layout, Photographs of installed SWHS & Declaration by the Manufacturer to comply with MNRE/HAREDA minimum technical specification for Solar Water Heating System. The ADC office will issue the NOC to the concerned authority i.e. HUDA/HSIDC/Municipal Corporation/ Urban Dev. Department after verifying the installation of solar Water Heating system in case of system upto 1000 LPD capacity. For systems of capacity more than 1000 LPD, the NOC will be issued by Director, HAREDA after joint inspection by a team of officers from the concerned district and HAREDA. 7. Installation of SWHS on deposit work basis HAREDA has expert manpower to design, supervise and install Solar Water Heating Systems as per the BIS specifications. HAREDA has been declared approved source for supply, installation and commissioning of Solar Water Heating Systems in the Haryana State. For the building project of private developers also, HAREDA may get the Solar Water Heating systems installed for which it will charge 5% of the system cost as service charges. -x- 6
7 FORMAT OF APPLICATION FOR CAPAPCITY APPROVAL OF SOLAR WATER HEATING SYSTEM 1. Name of the applicant: 2. Complete address 3. Site Address 4. Name of the architect: 5. Details of the site 6. Total covered area of the project: 8. No. of towers/storeys in each tower/dwelling units/ Type of flats/ rooms (in case of hotels)/ Beds (in case of Hospitals) etc 9. Size of the dwelling unit 10. No. of BHK in each unit 11. No. of toilets in each dwelling unit(du): 12. Occupancy in each DU: 13. Building plan attached 14. Terrace plan attached: 15. Load bearing capacity of the roof: Should be more than 50 Kg per m2 16. Consultants report on installation of SWHS attached; 17. Details of processing fee: D.D. No. Dated Amount Bank 18. Proposed capacity of SWHS as per HAREDA norms: 19. The list of document attached with this application: a) Processing fees as per HAREDA norms. b) Attached Building Plan of the building. c) Attached Terrace plan of the building which clearly shows shadow free area on terrace. d) Registration Certificate. e) Proposed layout plan of Solar Water Heating System. * For the existing building Sr. No.-3,4,5 are not mandatory. Signature of the authorised signatory 7
8 FORMAT OF SITE CLEARANCE/ VERIFICATION REPORT FOR CAPACITY APPROVAL OF SWHS TO BE SUBMITTED BY PO/APO 1. Proposed site of installation: 2. Site inspected on: 3. Details of the user: a) Name of the user/ developer: b) Head of the organization: With address c) Site Incharge / Contact person: d) Telephone nos/fax: 4. No. of dwelling units with size and BHK configuration of each: 5. Availability of cold water on roof: 6. Proposed use of hot water: 7. Shadow free space on roof: Available or not Available (approx. sq.m.) Building wise. 8. Load bearing capacity of the roof: 9. Electricity: Available/Not available 10. Approx. length of piping required: i) Hot- NB: m. ii) Cold -NB: m. 11. Availability of skilled worker for Maintenance of the system: 12. Comments on site: The solar water heating system of lpd Capacity is recommended / Not recommended. Proposal examined and all documents attached. 13. Final recommendation of HAREDA Project Officer/Asstt.PO Proposal found as per HAREDA norms. Capacity to be installed LPD. Auth. Signatory of HAREDA 8
9 FORMAT FOR APPLICATION FOR ISSUE OF NOC ON INSTALLATION OF SOLAR WATER HEATING SYSTEM IN GROUP HOUSING SOCIETIES/REAL ESTATE TOWER/ HOTELS/ HOSPITALS/ COMMERCIAL BUILDINGS. 1. Name of the applicant : 2. Complete address : 3. Site Address : 4. Contact person & his contact details : 5. Capacity of the system required to be : Installed as per HAREDA norms. (Please give details no. of towers. Flat, type of flats & nos. of storeys in each tower). 6. Capacity approved by HAREDA/PO & APO : of concerned district. (Please give details of HAREDA Correspondence on capacity approval of SWHS). 7. Whether the capacity is as per HAREDA norms or not : 8. System supplied by (Complete address of supplier with contact no., ) : 9. Whether the supplier is on the Rate contact : Of HAREDA or BIS approved manufacturer or Dealer of BIS marked manufacturer. 10. Validity of BIS/Empanelment : 11. Whether the system is comply with MNRE/HAREDA : Minimum technical requirement of SWHS. (Please give supplier declaration in this regard) 12. Cost of the installed system with 5 years AMC : (Attach invoice) 13. Whether the subsidy is claimed : If yes, mention applicable MNRE, GOI/State Subsidy. 14. The list of document to be attached with this application: a) Capacity approval letter from HAREDA/PO of concerned district. b) Allotment letter from HUDA/MC. c) Registration Certificate. d) Joint Commissioning Report as per HAREDA format. 9
10 e) Supplier BIS/MNRE approved test certificate. f) If supplier is dealer of BIS/MNRE approved system, then attached dealership certificate. g) Final Solar Water Heating System installed layout plan. h) Declaration by manufacturer to comply with MNRE/HAREDA minimum technical specification of SWHS. i) Photograph of installed system. Undertaking by the applicant: a) We will not dismantle the system at any stage without prior written permission of HAREDA. b) We will regularly use and properly maintain the system and submit quarterly performance report for a minimum period of one year from the date of installation through ADC office. c) We have installed the system as per HAREDA norms for capacity of the system and the system is comply with minimum technical specification of MNRE/HAREDA. Signature of the authorised signatory 10
11 FORMAT OF INSPECTION / VERIFICATION REPORT FOR ISSUE OF NOC ON INSTALLATION OF SWHS IN GROUP HOUSING SOCIETIES/REAL ESTATE TOWER/ HOTELS/ HOSPITALS/ COMMERCIAL BUILDINGS TO BE SUBMITTED BY PO/APO. 1. Name of Society/Real Estate Tower/ : Hotel/Hospital/Commercial Building. 2. Site inspected on : 3. Complete Address : 4. Contact person & his contact details : Capacity of the system required to be Installed as per HAREDA norms. (Please give details no. of towers. Flat, type of flats & nos. of storeys in each tower). 5. Capacity approved by HAREDA/PO & APO : of concerned district. (Please give details of HAREDA Correspondence on capacity approval of SWHS). 6. Whether the capacity is as per HAREDA norms or not : 7. System supplied by (Complete address of supplier with contact no., ) : 8. Whether the supplier is on the Rate contact : Of HAREDA or BIS approved manufacturer or Dealer of BIS marked manufacturer. 9. Validity of BIS/Empanelment : 10. Whether the system is comply with MNRE/HAREDA : Minimum technical requirement of SWHS. 11. Availability of skilled worker for : Maintenance of the system. 12. Comment if any : It is certified that the above Society/Real Estate Tower/Hotel/Hospital/Commercial Building has undertaken the installation of Solar Water Heating System of LPD. The system capacity and system technical specification are as per norms of MNRE/HAREDA. Date : Place: Signature of inspecting Officer Name: Designation: 11
12 JOINT COMMISSIONING REPORT OF SOLAR WATER HEATING SYSTEM Certified that a solar water heating system of..liter per day capacity has been installed at.. (Name of the institute)...city....district.. by M/S... on.. (Date).The system is as per BIS/HAREDA/MNRE specifications. The system has been checked for its performance on (Date) and it is working satisfactorily. Signature of the beneficiary Signature of the rep. of supplier With name and date with name seal and date Signature of the rep. of HAREDA/ PO/APO With name and date with name seal and date 12
13 Annexure-I MINIMUM TECHNICAL SPECIFICATIONS OF VARIOUS COMPONENTS OF FPC BASED SOLAR WATER HEATING SYSTEMS. 1. ABSORBER MATERIAL Absorber shall be of copper sheet and copper tube. Thickness of sheet 34 SWG (IS 191) Riser Diameter : mm Thickness : 0.56 mm (IS 2501) Number : As per BIS Header Diameter : Minimum mm Thickness : 0.71 mm Number : 2 Projection out side: 40 mm+0.5 mm Including flanges of the collector box. Space between Riser Tubes 120 mm maximum from centre to centre of the riser. The free edges at the sides not to exceed 60 mm from the centre of the extreme end riser tube. Bonding between Riser & Sheet For independent fins or joints in the sheet an overlap of minimum 2 mm shall be provided. Full length of all risers shall be welded with the absorber sheet. In case of brazing/soldering/tig welding of continuous nature, un-brazed/un-soldered portion should not exceed more than 10% of the length of the riser. For brazing/soldering, minimum 60% tin soldier or suitable brazing material shall be used. The flux used in soldering shall be mechanically removed and neutralized with the solution of sodium carbonate to avoid corrosion after installation. The flux used should be non greasy and non corrosive. Coating Selective coating with absorptivity >0.92 and emissivity< FLAT PLATE COLLECTOR Overall Dimensions(mm) Size Length Width Height A B 2120± ±10 100±10 Variation in size acceptable providing min. 2 sq.m. area/collector. 3. COLLECTOR BOX MATERIALS Aluminium Fabrication of the Box Attachment of Bottom Sheet Aluminium extruded sections of size approximately 100 mmx25mm channel sections (within the tolerance given above) and of thickness 1.6 mm for the sides 0.71 mm aluminium sheet for the bottom (Tolerance 10%). 1.2 mm thick aluminium angle (dimensions 25mmx25mmx1.2mm) retainer for glass Side channel shall be welded by inert arc or gas brazing to ensure leak proof continuity of the joints of the box. Bottom sheet may be joined with spot welding or self threaded nickel plated screws.in case of screw joint wooden battens shall be provided to secure the screws. The screwed/riveted joint shall be made leak proof by sealing paste of Zinc Oxide based or rubber based or silicon rubber based or epoxy based sealing compounds. 13
14 4. TESTING OF RISER-HEADER ASSEMBLY 5. COLLECTOR BOX INSULATION Back Insulation It should be tested for leakage and strength at a minimum hydraulic/neumatic pressure of 5 kg/sq.cm. Insulation shall be providing at back and sides. Thermal resistance (R) of insulation material shall be minimum 0.96 sq.m deg. C/W for back insulation and minimum 0.48 sq.m deg. C/W for side insulation. This shall be derived after determining thermal conductivity (K) value at 100 deg. C mean temperature in accordance with IS The thickness of the insulation material (L) may be derived by the equation R= L/ K or the insulation materials with following specifications may be used: Material name Rock wool Glass wool Mineral wool Side insulation 6. FRONT GLAZING Material thickness Transmittance General appearance of glass Aperture area Spacing between cover plate and Absorber surface K R Thickness density W/MK sq.m/w (MM) (KG/Cum) The insulation must with stand a temperature of 250 deg. C. Aluminium foil of thickness 0.015mm to 0.021mm shall be used for covering the back insulation 25 mm thick insulation of specification as mentioned above. Aluminium foil of thickness mm to 0.021mm shall be used of covering the side insulation. Glass wool Resin Bonded/Rockwool/Rigid Polyurethene of Thickness 25mm, minimum shall be used so as to achieve R value=0.08 as per IS 3346:1980. Single piece glass Toughened mm (IS 2553(Part-I) 82% (Minimum) Free from bubbles/rough surface 2.30sq.mt.(approx.)for size A collector 20 to 40 mm 7. HEADER FLANGES Brass flanges of 62+3 mm diameter and minimum thickness of 4 mm with provision of four number of GI plated nuts bolts with diameter of 6mm-8mm shall be used. Flanges shall be brazed to the header and brazing tested for leakage at the test pressure of 10kg/sq.cm. In no case crude soldered flanges shall be used. The assembly of the flanges should be at right angle to the header area to ensure proper assembly at the site of installation. 8. GROMMET Suitable sealing between the inlet and outlet of header and casing of the following materials shall be provided. Neoprene, EPDM, Silicon rubber or butyle rubber etc. The grommet shall be suitable for a temp. upto 125 deg. C and mechanical loading during transportation of collectors. 14
15 Typical size of grommet may be 40 mm outer dia and 25mm inner dia. 9. ASSEMBLY OF COLLECTORS The load of the absorber should not be on the insulation. It should be taken by the collector box. The air gap between the glazing and the absorber should be 25mm (+5mm). Insulation should not be allowed to slide. Glazing shall be fixed on the collector box by using EPDM/Neoprene/Synthetic rubber channels. The glass should be firmly held, without strain taking into account the expansions of glass. A typical example is by retaining the glazing with the help of self tapping screws and aluminium angle retainer of dimensions 25mmx25mmx1.5mm fixed on the top of the box it shall be ensured that the screws are not touching the glass edge. Top surface along the edge between the glass and the aluminium angle shall be caulked with suitable sealants such as zinc oxide based/rubber based/silicon rubber based or polysulphide rubber sealants. 10. GASKET FOR FLANGES 3 mm thick gasket of Neoprene/synthetic rubber gasket shall be used for sealing the joints between flanges. 11. COLLECTOR SUPPORT FRAME The structure should be in a position of withstand a wind velocity of 150 kms/hr. shall be made with angle iron of 35 mmx35mmx4mm; will have vertical support at top and bottom edge of the inclined plane of the collector at a distance of 1.5 M or less. The vertical support shall be firmly grouted with the roof. The non corrosive material or have corrosion resistant protective coating must be used. They will be strong enough to sustain their pressure during the lifetime of system. 12. PAINTING OF STANDS Proper cleaning and degreasing of the surface should be done with the help of three in one solution before painting. Two coats of zinc chromate red oxide primer shall be applied followed by two coats of enamel paint of suitable colour as per NIT. 13.STORAGE TANK(HOT WATER) a)material b) Thickness SS 304 or 316 grade min/ MS or any other material with anticorrosive coating for hard water with chlorine contents. Minimum thickness Tank capacity 15
16 20 gauge 20 gauge 20 gauge 18 gauge 18 gauge 18 gauge 16 gauge 14 gauge 14 gauge (0.91mm)for 100 lpd (0.91mm) for 200 lpd (0.91mm)for 500 lpd (1.2mm)for 1000lpd (1.2mm)for 1500 lpd (1.5mm)for 2000 lpd (1.6mm)for 3000 lpd (2.0mm) for 4000 lpd (2.0mm)for 5000 lpd For MS minimum thickness will be 1.5 mm. c) Insulation and installation Minimum 50mm thick with CFC free PUF having density of kg per Cu.mtr. For regions with sub zero temperatures, it will be doubled. 24 SWG thick aluminium sheet shall be used for cladding the tank insulation. The storage tank shall be properly installed at site using enameled coated appropriate size angle iron stands, girder, cement concrete pedestals of 1:2:3 ratio or any other specific provision suitable to site to ensure the stability against heavy storm etc. but not less than 1 x1 x6 dimensions. (d). Welding External of the tank should be properly insulated so that hot water temperature does not decrease by more than 5 deg. C in about 16 hrs. Time. TIG/Seam/ pressurized weld (Open arc weld not permitted) 14. PIPING Material Insulation 1 to 2 dia Medium class (B class) GI as per IS 1239 shall be used for piping. Minimum 50mm thick with CFC free PUF having density of kg per Cu.mtr. For regions with sub zero temperatures, it will be doubled. 26 SWG thick aluminium sheet shall be used for cladding the insulated pipe. The pipe line should be properly supported and fixed with clamp with the help of suitable size stand/civil structure (cement concrete ratio 1:4) ISI mark strainer of standard make should be fitted in the main cold water supply line before the system/ 15.VALVES/NIPPLE/TEES/BENDS Gun metal valve ISI marked shall be used. Nipple/tees and bends of ISI marked of medium class GI (B class) shall be used. Air vents in each row are to be provided. 16. INSTRUMENTATION Temperature gauge: 1 No. dial type (for Hot Water Storage Tank/Outlet) Gun metal stainer: 1 No. (at Cold Water inlet) 16
17 Water meter -1 at the inlet of cold water tank. Maximum 2 nos. of chrome plated brass taps for systems upto 200 lpd and thereafter 1 tap per 200 lpd of superior quality for distribution line. (ISI mark or standard make. 17. COLD WATER TANK HDPE/LDPE material with Gun metal float valve (ISI marked) equal to the capacity of Hot water storage tank. 18. MAKE UP TANK The capacity of makeup tank should be 5 litres up to 500 lpd and 10 litres for 1000 lpd and above made of SS304 minimum 0.8 mm thick. (ISI mark or standard make. 19. STANDS & PEDESTALS FOR THE TANKS (hot water tank/ cold water tank) The tanks will be mounted on stands made out of angle iron frame of 35x35x4mm up to 500 liters, 50x50x6 mm up to 2000lpd and 65x65x6mm for capacity above 2000 liters with each leg duly grouted with PCC 1:2:4 of 1 x1 x1 size. The cold water tanks will be placed over angle iron frame having 4 cross members in 4 legs with 5mm thick MS sheet for full bottom support fixed of 4 horizontal members based on the size of the cold water tanks. The non corrosive material or have corrosion resistant protective coating must be used. They will be strong enough to sustain their pressure during the lifetime of system. 20. SYSTEM LAYOUT & DESIGN Maximum number of collectors in series should not be more than ten. Maximum number of collectors in parallel in one row without the use of any piping connections should not be more than six. Air venting at appropriate places without hindrance of a spring leaded valve to prevent air locking in the system should be provided. For this purpose, the system shall have, at a suitable point, atmospheric pressure conditions preferably in the high temperature zone. System shall have a suitable expansion/make up tank at a high point in the system to ensure that collectors run full all the times. Capacity of this expansion/make up tank should be 1.5% of the system capacity for all systems. 21. PUMP In case of forced system, pump of suitable size with DTC/FTC control has to be provided as per site requirements. 22. HEAT EXCHANGER (ISI mark or standard make. (a) Shell-in-Tube Type (i) Material Copper for forced systems only. Shell in tube type heat exchanger may be used if U- type construction is not employed and if V-type construction is employed, then minimum 4 Nos. of heat exchangers will be used in series. 17
18 (ii) Tube Thickness Shell shall be designed for 1.5 times of the designed operating pressure and shall be tested for two times the operating pressure. In case of mild steel shell, corrosion allowance of 1.6 mm shall be provided. Shell shall be designed as per the BIS All the elements of heat exchanger shall be as per relevant Indian Standard or as per TEMA Class C construction. Minimum 22 SWG, but may be higher depending upon the designed pressure requirements. For thermosyphen systems only. May be used by incorporating Cu/SS coils/retender inside the storage tank Copper/SS tube of ¾ dia (b) Coil-type Heat Exchanger (i) Material (ii) Thickness (iii) No. of coils and flow Pattern 23. ELECTRICAL BACK UP Minimum 22 SWG. May be higher depending upon the pressure requirements. Shall be so designed to ensure the pressure drop less than 0.3 kg/cm. The surface area of the heat exchanger should not be less than 0.24 m 2 per sq.m of the absorber area of the system (for 100 lpd system, the copper tube length of 7 meter is required). For 100 lpd - 2 KW For 200 lpd- 2 KW For 300 lpd- 2x2 KW For 400 lpd- 2x2 KW For 500 lpd- 2x2 KW Electrical wiring of 2:5 mm sq. 2 core unarmoured cable, thermostat of Radssion /Bajaj Make with MCB of 16 amp. For 600 lpd- 6 KW For 800 lpd-9 KW For 1000 lpd-9 KW For above 1000 lpd-@ 9 KW per 1000 lpd Electrical back up control panel for 6 KW 1. DP switches 20 Amp. 2. Thermostat for auto cut Electrical back-up control panel for 9 KW 1. DP switches 1x32 Amp. 2. Thermostat for auto cut Anchor make or equivalent ABB/Sieman/Havel/ ISI MARKED Anchor make or equivalent ABB/Sieman/Havel/ ISI MARKED Wire should be of not less than 2.5 mm2 or 4mm2, Cu, armoured type 18
19 General Requirements i) System will be well grouted with collectors installed atleast 6 above the ground. It should be able to sustain the wind speed of 150 km per hour. ii) All the collectors will be south facing inclined at suitable angle to give best performance in winter iii) There will not be any shadow falling on the collectors from nearby structures or of other collectors in front or back row iv) Hot water pipe lines of any kind in colder regions will be fully insulated from the point of drawl of water from tank to delivery points. At no place, these will be left without insulation. In other regions also care will be taken to avoid heat losses from pipelines. v) System will be installed nearest to the point of hot water usage to avoid longer pipeline & higher heat losses. vi) The workmanship & aesthetics of the system will be good and it should be visible to anybody vii) Air vent pipe, make up water and cold water tanks will be installed as required for smooth functioning of the system viii) There won t be any leakage observed in the system from tanks/ collectors/ pipelines ix) Electric back up for systems above 100 lpd capacity will be provided through instant geyzer or through electric geyser already installed at usage places especially where storage capacity of geyser is less than 10 liter. This will avoid heating whole amount of water in storage tank and waiting time of heating if requirement of hot water is small. x) The FPC based systems will be from BIS approved manufacturers of flat plate collector (2 sq. m. absorber area for 100 liter tank capacity system). An undertaking will be given by the manufacturer/supplier confirming to above requirements. In case any manufacturer/supplier is found not sticking to above requirements, his name will be removed from MNRE/HAREDA list. Note: All salient featurers of the system including those mentioned above will be highlighted on a plate fixed on front surface of the tank alongwith name of manufacturer/ dealer & his contact No. 19
20 Annexure-II MINIMUM TECHNICAL SPECIFICATIONS OF VARIOUS COMPONENTS OF ETC BASED SOLAR WATER HEATING SYSTEMS. Evacuated Tube Collectors/ Heat pipes Type of tubes No. of tubes in a system Procurement : 3 layer solar selective (Inner layer of copper coating should be visible). Detailed specifications of tubes will be as per the guidelines laid down by MNRE for empanelment of Manufacturers of ETC based systems & made available at MNRE website (MNRE approved manufacturers/suppliers). : To have minimum 1 ½ sq. m. of absorber area for 100 liter tank capacity system. Absorber area will be calculated as Number of tubes X (exposed surface area of tube in meters i.e x radius of tube). For example 14 tubes of ID: 47 mm & length: 1500 mm and 10 tubes of ID 58 mm & length: 1800 mm will be required for each 100 lpd system. : From reputed supplier (Details of supplier to be provided) Storage Tanks, Piping, Support structure etc (To be all indigenous & not imported) Inner tank material Inner tank thickness Inner tank welding Storage tank capacity Thermal insulation of tanks & hot water piping Outer clading & Frames Valves, cold water tank, vent pipe, heat exchanger, make up tank & measuring instruments : SS 304 or 316 grade min/ MS or any other material with anticorrosive coating for hard water with chlorine contents. : For SS minimum thickness will be 0.5 mm when using argon arc or metal inert gas for welding and 0.8 mm when using other type of weldng. For MS minimum thickness will be 1.5 mm. No leakage under any kind of negative or positive pressure od water will be ensured. : TIG / Seam/ pressurized weld (Open arc weld not permitted) : Not less than system capacity. In case of ETC based system, volume of tubes & manifold not to be included in tank capacity. : Minimum 50mm thick with CFC free PUF having density of kg per Cu.mtr. For regions with sub zero temperatures, it will be doubled. : Al/SS/FRP or GI powder coated. MS may also be used with special anti-corrosive protective coatings. : Of ISI mark or standard make 20
21 Support structure for Collectors, pipng, tanks etc. : Of non corrosive material or have corrosion resistant protective coating. They will be strong enough to sustain their pressure during the lifetime of system. General Requirements i) System will be well grouted with collectors installed atleast 6 above the ground. It should be able to sustain the wind speed of 150 km per hour. ii) All the collectors will be south facing inclined at suitable angle to give best performance in winter iii) There will not be any shadow falling on the collectors from nearby structures or of other collectors in front or back row iv) Hot water pipe lines of any kind in colder regions will be fully insulated from the point of drawl of water from tank to delivery points. At no place, these will be left without insulation. In other regions also care will be taken to avoid heat losses from pipelines. v) System will be installed nearest to the point of hot water usage to avoid longer pipeline & higher heat losses. vi) The workmanship & aesthetics of the system will be good and it should be visible to anybody vii) Air vent pipe, make up water and cold water tanks will be installed as required for smooth functioning of the system viii) There won t be any leakage observed in the system from tanks/ collectors/ pipelines ix) Electric back up for systems above 100 lpd capacity will be provided through instant geyzer or through electric geyser already installed at usage places especially where storage capacity of geyser is less than 10 liter. This will avoid heating whole amount of water in storage tank and waiting time of heating if requirement of hot water is small. An undertaking will be given by the manufacturer/supplier confirming to above requirements. In case any manufacturer/supplier is found not sticking to above requirements, his name will be removed from MNRE/HAREDA list. Note: All salient featurers of the system including those mentioned above will be highlighted on a plate fixed on front surface of the tank alongwith name of manufacturer/ dealer & his contact No. 21
TECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC)
TECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC) Prepared by Committee for Technology Assessment and Analyzing the installation of Solar Water Heater Systems in Government
FREQUENTLY ASKED QUESTIONS (SOLAR WATER HEATER)
FREQUENTLY ASKED QUESTIONS (SOLAR WATER HEATER) Q.No.1 What is Solar Water Heater? A Solar Water Heater is a device which provides hot water for bathing, washing, cleaning, etc. using solar energy. It
INSTRUCTIONS FOR USE, MAINTENANCE AND INSTALLATION OF THE
SUN & HEAT SOLAR PRODUCTS INSTRUCTIONS FOR USE, MAINTENANCE AND INSTALLATION OF THE SOLAR DOMESTIC WATER HEATER THERMOSIPHON 150/2.5 (TYPICAL INSTRUCTIONS FOR A CLOSED LOOP THERMOSIPHONIC SYSTEM ON A FLAT
Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector
NOW AVAILABLE! the new ASW-58A-22/30 Solar Thermal Collector The ASW-58A-22/30 series of collectors are available in 22 and 30 tube units. Other sizes are available upon request. Each unit comes complete.
SOLAR HOT WATER SOLUTIONS stainless steel roof systems
SOLAR HOT WATER SOLUTIONS stainless steel roof systems RHEEM. SINCE 1937. Rheem has been manufacturing in Australia since 1937. Over seventy-five years later, Rheem is a household name and is as much a
32/1/2013-14/PVSE(Part-II) Ministry of New and Renewable Energy SPV Off Grid Division
Annexure-A 32/1/2013-14/PVSE(Part-II) Ministry of New and Renewable Energy SPV Off Grid Division Scheme: Installation of 10,000 nos. of solar photovoltaic water pumping systems for irrigation purpose implemented
UniPlate. Solar Collectors SOLAR SYSTEMS. www.solarico.eu
UniPlate Solar Collectors SOLAR SYSTEMS www.solarico.eu keep the sun in mind Solar energy has by far the highest theoretical potential of the earth s renewable energy sources. It is the most abundant energy
Solar Hot Water Heaters
Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless
SunMor SM-V30 Solar Water Heater Installation Manual
SunMor SM-V30 Solar Water Heater Installation Manual Rev. 1.02 Congratulations on the purchase of your new SunMor SM-V30 from Nature s Comfort LLC! You must read this entire instruction manual before beginning
After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
Session 2: Hot Water Supply
MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:
STATE BANK OF INDIA.
Page 1 of 5 B SANITARY, PLUMBING & DRAINAGE STATE BANK OF INDIA. PROPOSED RURAL SELF EMPLOYMENT TRAINING INSTITUTE AT RAIGARH IN C.G. DIRECTOR'S BUNGALOW SCHEDULE OF ITEMS-PLUMBING AND SANITARY WORK 1
AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun
AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun American Solar Water Heating Systems The American solar thermal system is more than just a solar water heater - it s the
ASME Packaged Indirect Fired Water Heater
Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining
SOLAR WATER HEATER USER AND INSTALLATION MANUAL
SOLAR WATER HEATER USER AND INSTALLATION MANUAL SOLAR WATER HEATER USER AND INSTALLATION MANUAL Non-pressure series solar water heater SZ58/1800-10 SZ58/1800-15 SZ58/1800-18 SZ58/1800-20 Index System
Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list
VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol
Solar hot water systems that give energy efficiency a whole new meaning
Solar hot water systems that give energy efficiency a whole new meaning The power to cut your energy bills for years to come When it comes to clean, cost effective energy solutions, the Leda Solar Hot
STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2
STANDARD for Plumbing, Heating, Hot Water, Cold Water & Electrical work undertaken by owners within the building known as Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers
Making Your Home Ready For Solar Water Heating
Making Your Home Ready For Solar Water Heating During construction or a major renovation, making a home ready to use solar energy can be easy and inexpensive. When the time comes to install your solar
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
James M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
CHAPTER NO. 27 QUANTITIES OF MATERIALS
CHAPTER NO. 27 QUANTITIES OF MATERIALS Note :- One cement bag weighs 50 kg. and measures 0.03472 cum. Sr. No. Description Unit Quantities Fine aggregates Coarse aggregates 1 2 3 4 5 6 27.1 Cement concrete
VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy
VIESMANN VITOSOL 200-F Flat-plate collector for the utilisation of solar energy Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 13 VITOSOL 200-F Type SV2 and SH2 Flat-plate
PART-II (COMMERCIAL / PRICE BID) DESIGN, SUPPLY AND INSTALLATION OF CUSTOMIZED STEEL LAB FURNITURE.AT N.C.C.S., PUNE
(An Autonomous Institution of the Department of Biotechnology, Govt. of India) N.C.C.S. Complex, Ganeshkhind, Pune University Campus, Pune 411007. PART-II (COMMERCIAL / PRICE BID) DESIGN, AND INSTALLATION
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A
Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as
TECHNICAL SPECIFICATION
THOMAS - G-FLEX GFLEX TECH SPEC CONNECTING INNOVATION JOHANNESBURG TEL: +27 11 794 7594 CAPE TOWN TEL: +27 21 556 5258 POLOKWANE TEL: 015 298 9142 DESIGNER, MANUFACTURER AND DISTRIBUTOR OF PIPE CONNECTION,
PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
HDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
Solar Hot Water. What systems are available?
Solar Hot Water Using the sun s energy to heat water will save you energy, lower your hot water bills, and reduce greenhouse pollution. Solar hot water systems work effectively in Victoria using mature
CEG/GP/1534/257/RFQ27016/ [01] Technical specification for NB 350 CB pipe :
[01] Technical specification for NB 350 CB pipe : Size :- NB 350 Plain End, ID 336 MM, OD 406 mm, Length - 5.3 meters +/- 25 mm Outer shell : Rolled and welded from 5 mm thick carbon steel coil / plates
Thermo Siphon Solar Systems
Thermo Siphon Solar Systems Thermo Siphon Solar Systems are a very cost effective way of producing hot water due to their simplicity in design and installation requirements. Usually more common in hotter
Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector
Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination
HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS
HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS INTRODUCTION 1. There are no general EU regulations and standards for outdoor swimming pool heating. Local regulations in the member countries are covering most
Free piston Stirling engine for rural development
Free piston Stirling engine for rural development R. Krasensky, Intern, Stirling development, [email protected] W. Rijssenbeek, Managing director, [email protected] Abstract: This paper presents
understanding medium frequency induction melting furnace and its components
understanding medium frequency induction melting furnace and its components 9 Spruce Street, Jersey City, NJ 07306 USA [email protected] INDUCTION MELTING FURNACE AND ITS COMPONENTS The purpose
SF15K SF05KSS, SF10KSS
Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification Number: 3503-11.2.610 Rev. 2 Rubber Lined Steel Pipe and Fittings Mechanically Coupled Plain End Type System Issued Revised Approved
Installation Manual. Thermomax Solar Water Heater ... Installation Procedure for Flatroof and Ground. Revision 8
. Thermomax Solar Water Heater Thermo Technologies 5560 Sterrett Place, Suite 115 Columbia, MD 21044 Thermoteks.com November 2005 Installation Manual.......... Installation Procedure for Flatroof and Ground
Solar Water Heaters. Three types of solar collectors are used for residential applications:
Solar Water Heaters Solar water heaters also called solar domestic hot water systems can be a cost-effective way to generate hot water for your home. They can be used in any climate, and the fuel they
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
BOQ for Plumbing, Sanitary Works
BOQ for Plumbing, Sanitary Works Page 1 of 6 Sr.No Item Description Quantity Unit Rate Amount (Rs.) 1 SANITARY FIXTURES Providing & Fixing star white colour vitreous china wall mounted wc with 1a heavy
1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels. W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd.
Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd. 1 The Kingspan Group Energy independent buildings for a sustainable
Solar Collector Series. Product List
Solar Collector Series List FULL COLLECTORS (MANIFOLD, TUBES & ROOF FRAME) : CSR00051 Apricus Collector : AP10 10-Way Manifold, 10 Tubes and Standard Roof Frame CSR00052 Apricus Collector : AP20 20-Way
Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized
Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized Gravity Solar System Installation Manual: This manual explains how to install a system of evacuated
Butt Fusion Welding of HDPE Pipes Work Procedure
Butt Fusion Welding of HDPE Pipes Work Procedure A pipeline is as good as its weakest point. Accordingly it is not only important that quality pipes and components are used in a piping system, but also
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
What to Expect From the Examination. How to Study the Plumbing Codes
Texas State Board of Plumbing Examiners Plumbing Inspector Examination Review Course The following Examination Review Course is designed to assist an applicant in preparing for the Plumbing Inspector examination.
BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"
BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP" Sl. 1 DISMANTLING WORK 1.1 Stripping off worn out plaster (outside and inside) and raking out joints
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
Please follow the instructions in this owners guide. Save this owners carefully guide for future reference.
Please follow the instructions in this owners guide carefully. Save this owners guide for future reference. Owner s Guide Solar Water Heater From Dear Friends, Greetings from Aurore. Congratulations on
Test Report No. C829QPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Westech Components Wuxi Co.,
WC flushing cistern single or dual flush 0.13 0.05 2 to fill in 2 minutes WC trough cistern 0.15 per WC 0.10 2 Wash basin tap size 1 2
HAC_C0.qxd 7/4/08 9: Page 74 Chapter Pipe sizing Pipes and fittings should be sized so that the flow rates for individual draw-offs are equal to the design flow rates shown in table.. During simultaneous
When Should Examination Preparation Begin?
Texas State Board of Plumbing Examiners Tradesman Plumber-Limited Licensee Examination Review Course The following Examination Review Course is designed to assist a registered Plumber s Apprentice in preparing
italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines
PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals
TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR
TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR 1.1.0 SCOPE : This specification covers design, manufacture, testing at manufacture s works before
Pipe Clamps and Accessories
Products 4.0 Products 4.1 Connection options to pipe clamps with Triple-Thread Connector NT 3G (M16, M10, M8) 4.2 Connection options to pipe clamps with Triple-Thread Connector NT 3G (3/8", M12, M10) 4.3
SECTION 15410 GROUND WATER STORAGE TANKS
SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design
TARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
Range Tribune HE Solar Unvented Direct and Indirect Cylinders
Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar cylinders have been designed specifically with Solar applications in mind and are based on the highly successful Range
T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
UGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
GK Packing System Welding Instructions
GK Packing System Welding Instructions Roxtec GmbH Neuer Höltigbaum 1-3, 22143 Hamburg GERMANY Tel +49 (040) 657398-0, Fax +49 (040) 657398-50 EMAIL [email protected], www.roxtec.de Welding instructions
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
TANKLESS WATER HEATER INSTALLATION DIAGRAMS
TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water
Vacuum Tube Solar Water heater Non-pressure. User manual
Vacuum Tube Solar Water heater Non-pressure User manual Please read this manual carefully before beginning installation Specification Tubes 12 --- 30 58X1800 Nominal volume tank capacity 100L --- 300L
Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual
Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction
How To Use An Akua Magnetic Lime Scale Preventing Device
AKUA MAGNETIC LIMESCALE PREVENTING DEVICES INTRODUCTION AND OPERATING MANUAL This manual contains information about Akua Magnetic Lime Scale Preventing devices, their assembly and usage rules. In order
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES Interpretations of the FTP CONTENTS FTP1 Adhesives used in A or B class divisions (FTP Code 3.1, Res A.754 para. 3.2.3) June 2000 FTP2 Pipe and duct
DENVER MODEL 30 X 30 SPECIFICATIONS
DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy
VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy Datasheet Part no. and prices: see pricelist VITOSOL 200-F Type SV2A/B and SH2A/B Flat-plate collector for vertical or horizontal
SOLAR HEATING SYSTEMS. www.orkli.com
SOLAR HEATING SYSTEMS www.orkli.com // 2 Orkli is one of the main European manufacturers of components for household appliances and innovative solutions for the comfort sector. Its corporate activity is
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
Power Cube Open Source Ecology Page 1. Power Cube. Version 4
Power Cube Open Source Ecology Page 1 Power Cube Version 4 Power Cube Open Source Ecology Page 2 Contents Table of Contents Power Cube... 1 Contents...2 Introduction... 3 Bill Of Materials...4 Discrete
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
maximise the sun s energy with warmflow solar Warmflow Solar
maximise the sun s energy with warmflow solar Warmflow Solar Warmflow Solar warmflow solar - the perfect choice Warmflow has been established as a privately owned company since 1970. During this time we
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Light Duty Commercial Electric Water Heater
Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and
60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
A World Class Manufacturer of Induction Bends
A World Class Manufacturer of Induction Bends COFELY FABRICOM BENDING A leading position in bending High Flexibility and Close Tolerances As a world leading manufacturer of pipe bends, produced by induction
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
6 YEAR * PAYBACK A GUIDE TO DOMESTIC RENEWABLE HEAT INCENTIVE (RHI) SOLAR THERMAL SOLUTIONS
6 YEAR * PAYBACK A GUIDE TO DOMESTIC RENEWABLE HEAT INCENTIVE () SOLAR THERMAL SOLUTIONS RENEWABLE HEAT INCENTIVE KINGSPAN SOLAR RENEWABLE HEAT INCENTIVE () EXPLAINED The Renewable Heat Incentive is intended
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING
PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING LI CHUNYING DOCTOR OF PHILOSOPHY CITY UNIVERSITY OF HONG KONG FEBRUARY 2012 CITY UNIVERSITY OF HONG KONG 香 港 城 市 大 學 Performance Evaluation of Water-flow
Energy Efficiency in Buildings
Energy Efficiency in Buildings Supplemental Guide to SANS 10400-XA & SANS 204 V. 3.0 Registered to: The Drawing Studio Image: digitalart / FreeDigitalPhotos.net Report Date: 26 August 2014 Practice Name:
Aquamax Australia Pty Ltd ABN 17 138 189 689
Aquamax Australia Pty Ltd ABN 17 138 189 689 AQUAMAX SERVICE MANUAL Stainless Steel Electric Water Heaters AQ0903010-A Revision: A Published: November 2012 E80 to E315 Series Contents Introduction... 3
Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.
Price List Rev.2 2010 AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com [email protected] SOMMARIO INDEX SOLAR SYSTEMS... page 10 COMPONENTS
SERVER ROOM CABINET INSTALLATION CONCEPTS
SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the
UNDERSTANDING CENTRAL HEATING SYSTEMS
UNDERSTANDING CENTRAL HEATING SYSTEMS This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential basic
VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
NATIONAL INSTITUTE OF BIOLOGICALS
Short Term Notice Inviting Quotations Quotations No. S.1-36/07/NIB/Engg. (Civil) Invitation to short term quotations for Repairing of damaged gypsum board false ceiling and painting with epoxy paint in
Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS
Solar MAX ELECTRIC BOOSTED SPECIFICATIONS Proudly Australian ALL AUSSIE GAS & ELECTRIC BOOSTED WATER S Harness the power of the Sun. 1 Energy efficiency that s out of this world AquaMAX high efficiency