1 BEDFORDSHIRE FIRE AND RESCUE SERVICE FIRE SAFETY GUIDANCE NOTE NO 40 DANGEROUS SUBSTANCES AND EXPLOSIVE ATMOSPHERES REGULATIONS 2002 STORAGE OF PETROLEUM SPIRIT AND OTHER HIGHLY FLAMMABLE LIQUIDS IN CANS, DRUMS AND OTHER CONTAINERS 1 Introduction The primary legislation applying to the control of substances that can cause fires and explosions in the workplace is the Dangerous Substances and Explosive Atmospheres Regulations 2002 (DSEAR) (SI 2002 No.2776). The storage of petroleum spirit and mixtures of petroleum was licensable prior to the Dangerous Substances and Explosive Atmospheres Regulations 2002 (DSEAR). The Petroleum (Consolidation) Regulation 2014 has subsequently amended the requirement for licensing petroleum except for specific limited storage in domestic or premises that are not deemed a work place (up to 275 litres provided it is not for sale / dispensing. The regulation provides detail on relevant quantities that can be stored for domestic and other relevant uses, FSGN 39 provides further details. The Dangerous Substances and Explosive Atmospheres Regulations 2002 (DSEAR) provides the detail for the storage requirements of flammable liquids. Under Section 5 of DSEAR a risk assessment is required for storage at a workplace of flammable liquids including petroleum (and other dangerous substances such as acetylene) and the original guidance for the storage of petroleum could be used as a benchmark for that risk assessment. There is a requirement in Section 6 of DSEAR very similar to that in Article 12 of the Regulatory Reform (Fire Safety) Order 2005 (FSO) to reduce or eliminate the risk, with a preference for replacement in order to eliminate the risk. 2 Standards of Storage The storage of petroleum spirit, mixtures of petroleum and highly flammable liquids should be in accordance with the standards specified in the Health and Safety Series booklet HSG51 'The Storage of Flammable Liquids in Containers (HSE Books). THE FOLLOWING SECTIONS ARE FOR GENERAL GUIDANCE ONLY AND DO NOT REFER TO ALL PARTS OF THE ABOVE STANDARDS. THEY MUST NOT BE CONSTRUED AS REPRESENTING THE FULL RECOMMENDATIONS IN RESPECT OF ANY SPECIFIC PROPOSALS FOR STORAGE. Storage in retail premises or laboratories etc is covered in HSG Fsgn 40

2 3 Siting and Construction All storage areas and buildings, rooms, cupboards and bins used for storage of petroleum spirit, petroleum mixtures and highly flammable liquids, should be sited and constructed in accordance with the standards specified in HSG 51. Alternative designs, materials and methods may be suitable where they provide an equivalent or higher overall level of safety. 3.1 Storage is Satisfactory in the Following Locations: a. In the open air. b. In separate buildings. c. In stores forming part of other buildings. 3.2 Storage in Open Air: Containers in the open air should be sited in a well ventilated position away from sources of ignition. The location should minimise the effect of heat on the containers from a fire within the premises or outside the boundary. It should also minimise the effect of a fire at the container store on buildings, plant and people, inside or outside the premises. Containers should be stored within a clearly-defined area on a concrete pad or other impervious surface. The minimum distance between the edge of the area and any occupied building, boundary, process unit or fixed source of ignition, should be as set out in the following table. In some cases, it may be necessary to increase the separation distance or provide additional protection; for example, if there are problems with the local water supply, or if the site is remote, or if it is close to process plant. 3.3 Minimum Separation Distances: Quantity stored: litres (l) Distance from occupied building, boundary, process unit, flammable liquid tank or fixed ignition source: metres(m) Up to , ,000 and above 7.5 Notes: a. The maximum stack size should be 300,000 litres, with at least 4 metres between stacks. b. Containers should not be stored within the bund of a fixed flammable liquid tank, or within 1 metre of a bund wall. 2 Fsgn 40

3 If adequate separation distances cannot be achieved, they may be reduced in appropriate cases, as long as an adequate fixed water-spray cooling system or fixed fire equipment is provided. Alternatively, a fire wall of an approved standard may be used. Prior advice should be sought from the Fire and Rescue Service. A fire wall should be imperforate, of at least half hour fire resistance, weather resistant, and sufficiently robust to withstand foreseeable accidental damage. Means of controlling spillage should be provided. This may be an impervious sill or low bund, typically 150 mm high, big enough to hold 100% of the contents of the largest container. An alternative is to drain the area to a safe place, such as a remote sump or a separator. Absorbent granules or other means of clearing up small spills should be provided. The surface of the storage area should be sloped so that any spillage does not accumulate around containers, but can drain to an evaporation area (within the storage area or separate from it) or to a sump or interceptor. No combustible material (including vegetation) should be permitted in the storage area, or within 1 metre of the sill or bund wall. Weedkiller containing sodium chlorate should not be used to kill the vegetation because of the increased fire hazard. Containers should be filled to allow adequate ullage space (about 5%) for liquid expansion. Shading from direct sunlight is not needed unless the material stored is unstable, or exceptionally if adequate ullage is not provided. Any shading or weather protection for open-air stores should be in the form of a light non-combustible roof structure, with open sides which do not restrict ventilation. In order to prevent trespassing or tampering, storage areas should be enclosed by a substantial fence at least 1.8 m high, unless the storage is otherwise protected; for example, by being within the security area of larger premises. The fence should not obstruct ventilation. Suitable types include welded mesh and chain-link fencing. At least two separate exits should normally be provided, although one is sufficient, if the distance from any part of the store to the exit is not more than 24 m, measured around the containers. Exits should open outwards, should not be self-locking, and easily openable from inside when the store is occupied. They should be kept locked when the store is unoccupied, with access to the keys restricted to authorised persons. 3.4 Storage in Separate Buildings: If containers are stored in a building used only for that purpose, the building need not be fire-resistant if it is in a safe position. It should, however, be of generally noncombustible construction if it holds containers with a total capacity of more than 400 litres. In this case, 'safe position' means a place where the distance between the outside wall of the building and any other building, boundary etc, is at least the appropriate distance in the table at 3.3 above. Storage buildings may, however, be sited on a boundary if: a. The wall of the building on that side is a fire wall to its full height (at least 2 m), and b. either the walls of the building at right angles to the boundary are fire walls to their full height for at least 4 m from the boundary, or c. the fire wall extends along the boundary for at least 4 m beyond the store on either side and to a height of at least 2 m. 3 Fsgn 40

4 A similar standard should be applied for storage buildings located against the wall of an occupied building. If the storage building is not in a safe position, it should be a fire-resisting structure, as described below: a. Each enclosing element, eg walls, doors, windows, floors and ceilings, should be at least half-hour fire-resistant to BS 476: Parts 20 to 23. b. Exceptions are floors immediately above the ground, and tops or ceilings of single-storey buildings and of top-floor rooms. c. For doors, the insulation requirement is waived. d. No glazing is allowed in internal walls forming part of the storeroom enclosure. e. In the event of fire, the standard of fire-resistance should allow adequate time, for the alarm to be raised, for people to escape and for firefighting to be put in hand. The standard does not require the enclosure to withstand a complete burn-out of the contents. It is nevertheless, recommended that the walls be sufficiently strong and weatherproof, either concrete, masonry or of brick construction. f. External windows should be of Georgian wired glass or other material of equivalent fire-resistance and should be non-opening. g. All internal surfaces should be at least Class 1 if tested to BS 476: Part 7 (Surface Spread of Flame). Exceptions are floors and doors, as well as windows and their frames. h. Doors should be self-closing from any position, except doors which lead directly out of the building. i. Junctions between elements of construction should be bonded or firestopped to prevent or retard the passage of flame and hot gases. j. The structure should be robust enough to withstand foreseeable accidental damage. k. If surfaces of the structure are liable to be coated with residues, the structure should allow for removal of the residues without affecting its fire-resistance, or its ability to resist flame spread. 3.5 Stores Forming Part of Other Buildings: Flammable liquid stores forming part of a building used for other purposes should be of fire-resisting construction in accordance with 3.4, with the fire-resistance requirements being applied to internal as well as external walls. Such stores should not be below ground, and should be sited so that escape routes from any part of the building are not put at risk in the event of a fire. Where the total quantity of flammable liquid storage does not exceed 50 litres, it may be kept in a workroom in a suitably placed cupboard or bin conforming to the specification contained in paragraph 163 Figure 13 of HSG Fsgn 40

5 If the storeroom shares a common roof structure with the rest of the building, protection should be provided against fire spreading via the roof space. This can be done by providing half-hour fire-resisting separation, either horizontally between the ceiling of the store and the roof space or vertically in the roof space between the store and the rest of the building. If a storeroom is in the same building as residential accommodation, one hour fireresisting separation should be provided between the two but preferably with no connecting doors. If doors are necessary, they should be of at least one hour fireresistance and should be self-closing. Automatic Fire Detection is recommended in the store linked to audible alarms in the residential area. 4 Ventilation, Heating and Lighting, and Explosion Relief 4.1 Ventilation Storerooms and buildings should be adequately ventilated to disperse vapour from any leakage or spillage. A standard of at least five air changes per hour is recommended, using air bricks, louvres, etc on external walls. The openings should have a total area of at least 1% of the area of the walls and roof. For stores which form part of a larger building the store should, where reasonably practicable, have at least two external walls, in which ventilation openings can be fitted. Ventilation openings should not be provided in internal walls. Low-level openings should be above the height of any spillage-retention sill. Ventilation openings should not be obstructed by stacks of containers and should be kept free of dirt and rubbish. Ventilation openings should not be provided in any part of the building which is required to be fire-resistant (i.e. which is within the appropriate distance in the table at 3.3). Where this causes difficulties in providing adequate ventilation, it may be possible to construct the openings using intumescent materials, which in the event of fire will expand and seal the opening. An alternative is to provide mechanical exhaust ventilation, with the exhaust air routed to the open air via fire-resisting ducting. The fan motor should be located outside the ducting, either in a nonhazardous area, or protected to a Zone 2 standard (see paragraph 7). The ventilation should be kept in operation at all times and an airflow indicator, linked to an audible or visible alarm, should be fitted to give warning of failure. 4.2 Heating Any heating provided in the store should not be able to act as a source of ignition. Hot water radiators and steam pipes are generally suitable and electric heaters may be used if protected to Zone 2 standards. Screens may be necessary to prevent containers being stacked too close to hot surfaces. The hot surface of any heater should always be at a temperature below the auto-ignition temperature of any stored liquids. If a ducted warm air system is used, the heater should be located in a safe area. There should be no possibility of flammable vapour being ignited by hot surfaces and adequate ventilation of the store should be maintained. 5 Fsgn 40

6 4.3 Storage Areas External storage buildings (whether or not they are fire-resisting structures) should have a lightweight roof to act as explosion relief. For internal stores in single-storey buildings it may also be possible to incorporate this type of roof. Alternatively, relief panels may be provided in one or more walls, provided that the relief can vent to a safe place. An alternative for both internal and external storage buildings is to provide sufficient mechanical ventilation to remove flammable vapour released in the event of an incident. (See 67 and 68 of HSG51 concerning ducting and fan motors). The advice in sub-paragraph 3.3 on provision and locking of exits also applies to internal and external storage buildings, although the maximum travel distance in storage buildings with a single exit should not exceed 18 m. Container stores and storage areas should be adequately lit when in use. The average illuminance at ground level should be at least 100 lux. More detailed guidance is contained in booklet HSG38 'Lighting at Work' (HSE Books). 5 Spillage Containment In storerooms and buildings, means of containing spillage should be provided: for example, a sloping floor or a 150 mm sill across door openings. Ramps may be provided for ease of access for wheeled trolleys etc. The floor should be impermeable and inert with respect to the liquids stored. 6 Electrical Installation Electrical installations should be ATEX rated in accordance with the Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations 1996 (or an equivalent standard) appropriate to the area classification, which is current at the time of installation or modification. Equipment should be marked with the symbol below. Where reasonably practicable, electrical equipment should be installed in nonhazardous areas. 6.1 Electrical Certificate A periodic electrical test certificate for the installation, signed by a competent person being fully conversant with and having practical experience of the necessary standard should be available on the licensed premises. 6.2 Hazardous Areas Hazardous areas in relation to electrical equipment are classified into the following hazard zones: Zone 0: In which an explosive vapour-air mixture is continuously present, or present for long periods. Zone 1: In which an explosive vapour-air mixture is likely to occur in normal operation. 6 Fsgn 40

7 Zone 2: In which an explosive vapour-air mixture is not likely to occur in normal operation, and if it occurs, it will exist only for a short time. Areas outside these zones are defined as non-hazardous Hazardous Area Classification The following table describes a typical hazardous area classification for containers of liquids with a flashpoint of less than 32 C. The table gives general guidance only, as local conditions should always be taken into account when carrying out a classification exercise. Typical Hazardous Area Classification: Item Extent of Area Classification Storerooms Every part* Zone 2 and buildings Cupboards and Every part Zone 2 Bins Open air Vertically to 1 m above Zone 2 storage areas top of highest container, and horizontally to 1 m beyond bund or sill * Note: For rooms and buildings which are well ventilated (see sub-paragraph 4.1), areas more than 2 m above the top of the highest container can be considered safe areas. 6.3 Vehicles Vehicles which need to operate within the hazardous areas associated with container stores and storage areas, should be protected against igniting flammable vapour. Guidance on the standards of diesel-engine lift trucks in Zone 2 areas is in HSE Guidance HSG113 'Lift Trucks in Potentially Flammable Atmospheres' (HSE Books). For other vehicles, specialist advice should be obtained. Battery charging should not be carried out in hazardous areas and vehicles should not be parked in such areas. 7 Other Sources of Ignition There should be no means of igniting flammable vapour within hazardous areas associated with storage of flammable liquids. This includes portable equipment such as unsuitable heating appliances (see sub-paragraph 4.2), hand lamps and welding sets. Smoking should be prohibited and 'No Smoking' signs should be posted. If any hot work is necessary, it should be done by trained personnel in accordance with a safe system of work. Guidance on permit-to-work systems is available in INDG98 HSE Books 1997 ISBN Where hot work on a container is proposed, precautions against igniting flammable materials in the container are essential. The container should be removed from the storage area to a safe place before work starts. 7 Fsgn 40

8 8 Design and Construction of Containers All containers should be designed and constructed to standards suitable for the purpose. They should be robust and provided with well-fitting lids or tops to resist spillage if knocked over. For steel drums BS 814 is suitable, while for freight containers BS 3951: Part 2, or an equivalent standard should be used. For plastic containers of approximately 5 to 10 litres capacity, the general standards in the Approved Code for plastic petrol containers may be used. If glass or other fragile containers are used, the packaging should include protection against impact damage, and may also include absorbent material to help contain the contents if a breakage occurs. Where necessary, containers should be protected against corrosion (for example by painting) and degradation by light (by suitable shading). In addition, the material used in the construction of the container should be compatible with the chemical and physical properties of the liquid to ensure that no interaction occurs which might cause leakage. 9 Small Quantities Cans and other small containers, up to 50 litres total capacity, may be kept in a workroom in a suitably-placed fire-resisting cupboard or bin. Cupboards and bins should be constructed to the following standards: a. Each side, top, floor and lid should be able to satisfy BS 476: Parts 20 and 22 with regard to freedom from collapse and resistance to passage of flame for at least half an hour. b. The internal surface material (and any substrate to which it is bonded) should, if tested to BS 476: Part 6 (fire propagation test) have an index of performance of not more than twelve, and a sub-index or not more than six. c. Junctions between each side, top and floor should be bonded or fire stopped to prevent or retard the passage of flame and hot gases. d. The structure should be robust enough to withstand foreseeable accidental damage. e. If surfaces of the structure are liable to be coated with residues, the structure should allow for removal of the residues without affecting its fire-resistance. f. Each side, top and floor should be supported and fastened to prevent failure of the structure in a fire for at least half an hour. Supports and fastenings should be non-combustible if tested to BS 476: Part 4, or if tested to BS 476: Part 11 should not flame and should give no rise in temperature on either the centre (specimen) or furnace thermocouples. 8 Fsgn 40

9 10 Notices Storerooms, cupboards and bins need to be marked with the yellow hazard triangle symbol Flammable Liquid. If it is not reasonably practical to mark directly on the storage area, then it can be displayed nearby as in Figure 1below; Figure 1 Figure 2 A Hazard Zone warning sign should be displayed at the point of entry to a potentially explosive atmosphere process risk such as where highly flammable liquids are in use or exposed in a defined hazard zone, as in Figure 2 above. The signs are black letters/symbols on a yellow background. No Smoking and No Naked Lights notices may also be appropriate in accordance with the Health & Safety (Safety Signs and Signals) Regulations Firefighting Equipment Firefighting equipment should be provided at readily accessible locations at the storage area; for example at access points to container stacks and at exits of storage buildings. Fire extinguishers should comply with BS EN 3 and be of at least 223B rating; for example a 9 kg Dry Powder extinguisher or a 9 litre Foam. In order to guard against equipment failure, it is preferable at all but very small installations to have extinguishers grouped in pairs. Where necessary on larger sites, hand-held extinguishers should be supplemented by bigger units, such as 50 kg powder extinguishers or mobile foam equipment of 100 litre pre-mix capacity. All equipment should be located where it is readily available to plant operators. Protection against the weather may be required. For storage in buildings, two foam or dry powder extinguishers with a total rating of at least 223B should be provided for stores up to 20,000 litres capacity. For larger stores, two additional extinguishers of the same total rating should be provided. Extinguishers should normally be located at the exits to the store. Alternatively, extinguishers can be selected, sized and located in accordance with BS 5306: Part Emergency Procedures and Training A procedure should be drawn up to deal with fires and leaks. It may be necessary to consider incidents in other parts of the premises or in adjacent premises. Everyone on site should be informed of the hazard from flammable liquids stored there and of the need to keep sources of ignition and heat away from the store. Those handling flammable liquids should also receive specific training in both normal operating procedures and emergency procedures. Periodic re-training will also be necessary. Training should, where appropriate, cover: a. Safe operation of the installation and its associated equipment. b. Use of protective clothing. c. Housekeeping. 9 Fsgn 40

10 d. Reporting of faults and incidents, including minor leaks and spills. e. Emergency procedures, including means of raising the alarm, calling the Fire Service, evacuation procedures, using the appropriate firefighting equipment and controlling spills and leaks. f. Relevant storage recommendations in the risk assessment. 13 Maintenance and Modification Storage areas and buildings, rooms, cupboards and bins used for storage, must be adequately maintained and electrical installations and equipment regularly tested and inspected. The electrical certificate requires annual renewal, in accordance with the Institute of Electrical Engineers (IEE) guidance. Consideration should be given at the planning stage to the hazards that any proposed modifications may cause and a risk assessment carried out before any such work commences. References: Health and Safety Series booklet (HSG51) The Storage of Flammable Liquids in Containers (HSE Books 1998) Further advice: Advice is available either by contacting the relevant department of the District or Borough Council responsible for the administration of the licensing procedure or by contacting: Bedfordshire Fire and Rescue Service Northern Area Office Barkers Lane BEDFORD MK41 9SB Bedfordshire Fire and Rescue Service Southern Area Office Studley Road LUTON LU3 1BB All telephone enquires (01234) Fsgn 40

FLAMMABLE LIQUIDS COMPLIANCE NOTE

FLAMMABLE LIQUIDS COMPLIANCE NOTE Issued by: Heather Rice Page: 1 of 7 COMPLIANCE NOTE INTRODUCTION This document provides additional guidance to support the Arrangement on Flammable Liquids (Ref No. CYC/HS/A27) CONTENTS Section Topic

More information

Wilkins Safety Group

Wilkins Safety Group H & S Guidance - Flammable Liquids See also: other pages INTRODUCTION Flammable liquids are liquids with a flashpoint of 55ºC or below and hence includes all liquids that are classified as flammable, highly

More information

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario Fire Code, Part 4, and of the Regulations for

More information

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable

More information

Flammable Liquids Storage

Flammable Liquids Storage A Health and Safety Guideline for Your Workplace Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario

More information

Flammable Liquids Storage

Flammable Liquids Storage A Health and Safety Guideline for Your Workplace Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario

More information

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders STORE HAZARDOUS SUBSTANCES SAFELY Suitable containers incompatibles gas cylinders Oxy-Acetylene welding flammable substances 35 36 STORE HAZARDOUS SUBSTANCES SAFELY STORE HAZARDOUS SUBSTANCES SAFELY Storing

More information

How To Write A Fire Risk Assessment

How To Write A Fire Risk Assessment Fire Safety Risk Assessment This form is to aid you in carrying out a fire safety risk assessment of a property. The form is separated in to two parts: Part 1 initial assessment form and guidance notes

More information

JOINT CBA AND SIA GUIDANCE FOR THE STORAGE OF FLAMMABLE LIQUIDS IN SEALED PACKAGES IN SPECIFIED EXTERNAL STORAGE AREAS

JOINT CBA AND SIA GUIDANCE FOR THE STORAGE OF FLAMMABLE LIQUIDS IN SEALED PACKAGES IN SPECIFIED EXTERNAL STORAGE AREAS JOINT CBA AND SIA GUIDANCE FOR THE STORAGE OF FLAMMABLE LIQUIDS IN SEALED PACKAGES IN SPECIFIED EXTERNAL STORAGE AREAS 1 JOINT CBA AND SIA GUIDANCE FOR THE STORAGE OF FLAMMABLE LIQUIDS IN SEALED PACKAGES

More information

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes FLAMMABLE AND COMBUSTIBLE LIQUIDS OSHA Changes Introduction This module covers the two primary hazards associated with flammable and combustible liquids: explosion and fire. In order to prevent these hazards,

More information

Spray Booth Guideline

Spray Booth Guideline Department of Development Service 135 North D Street, Perris CA. 92570 Phone: (951) 443-1029 Fax: (951) 943-3293 PURPOSE The intent of this guideline is to provide the information necessary to ensure that

More information

Site and Storage Conditions for Class 3.1 Flammable Liquids

Site and Storage Conditions for Class 3.1 Flammable Liquids Site and Storage Conditions for Class 3.1 Flammable Liquids Introduction Contents Introduction... 1 SITE AND STORAGE CONDITIONS...2 Part 1 General Flammability Conditions...2 Part 2 Conditions Relating

More information

Controlling fire and explosion risks in the workplace

Controlling fire and explosion risks in the workplace Controlling fire and explosion risks in the workplace A brief guide to the Dangerous Substances and Explosive Atmospheres Regulations Introduction to DSEAR This leaflet provides a brief introduction to

More information

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS Fire Safety Technical Guide UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS 1.0. BACKGROUND 1.1. The Regulatory Reform (Fire Safety) Order (known Fire Safety Order) applies to England and Wales (Northern

More information

Storage of flammable liquids in containers

Storage of flammable liquids in containers Storage of flammable liquids in containers This guidance is for those responsible for the safe storage of flammable liquids in containers at the workplace. It applies to storage of flammable liquids in

More information

Suffolk County Department of Health Services. Division of Environmental Quality

Suffolk County Department of Health Services. Division of Environmental Quality Suffolk County Department of Health Services Division of Environmental Quality Guidelines For the Construction of Storage Areas for Portable Containers ~~~~ Clare B. Bradley, M.D., M.P.H. Suffolk County

More information

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to

More information

Fire Safety Log Book

Fire Safety Log Book Fire Safety Log Book Company... Address........ Responsible Person. Competent Person. Date Started For Additional Information: Safety Management (UK) Ltd Holme Suite, Clawthorpe Hall Business Centre, Burton

More information

The terms hazard and risk are often used, which we define as the following:

The terms hazard and risk are often used, which we define as the following: Fire Safety Last updated in October 2010 This information sheet aims to give safety reps a basic understanding of fire safety and fire risk assessments under the current law. More detailed information

More information

THE FACTORIES A D OTHER PLACES OF WORK ACT (Cap 514)

THE FACTORIES A D OTHER PLACES OF WORK ACT (Cap 514) THE FACTORIES A D OTHER PLACES OF WORK ACT (Cap 514) I EXERCISE of the powers conferred by section 41 2(k) of the Factories and other places of Work Act, the Minister for Labour and Human Resource Development

More information

Petroleum (Consolidation) Regulations 2014

Petroleum (Consolidation) Regulations 2014 Petroleum (Consolidation) Regulations 2014 Introduction of new Petroleum Regulations On 1 October 2014 the Petroleum (Consolidation) Regulations 2014 are scheduled to come into force. Who do the Regulations

More information

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No General Inspection FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS 1. All Floors (inspect from top floor to basement): Yes are fire exits and directional signs properly illuminated? is the emergency

More information

Greater Manchester Fire and Rescue Service

Greater Manchester Fire and Rescue Service Greater Manchester Fire and Rescue Service Record of Fire Safety Equipment Testing CONTENTS 1. MEANS OF ESCAPE 2. FIRE WARNING AND AUTOMATIC FIRE DETECTION 3. FIRE EXTINGUISHERS AND HOSEREELS 4. EMERGENCY

More information

1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety.

1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety. Management Checklist 1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety. 2. Fire Hazard and Risk Assessment. Use

More information

Sample Written Program. For. Flammable Liquids

Sample Written Program. For. Flammable Liquids Sample Written Program For Flammable Liquids 1 Flammable Liquids. (YOUR COMPANY NAME) Purpose Proper Storage and use of flammable liquids can significantly reduce the possibility of accidental fires and

More information

FIRE RISK ASSESSMENT

FIRE RISK ASSESSMENT REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT This template has been provided to assist the Responsible Person with the preparation of a Fire Risk Assessment and is not intended for commercial

More information

Fire Safety Requirements for Child Care Centre

Fire Safety Requirements for Child Care Centre Fire Safety Requirements for Child Care Centre A. Restrictions on Location Child care centre shall not be located : - (a) (b) in any premises designed for residential use; in any industrial building, warehouses,

More information

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS The attached self-inspection form is intended for staff use at regular, frequent intervals. It should not take the place of two other vital measures

More information

Flammable Liquids 29 CFR 1910.106

Flammable Liquids 29 CFR 1910.106 Flammable Liquids 29 CFR 1910.106 OSHA s Directorate of Training and Education These materials were developed by OSHA s Directorate of Training and Education and are intended to assist employers, workers,

More information

Risk Management Guidelines

Risk Management Guidelines Fire Prevention on Construction Sites The Joint Code of Practice on the Protection from Fire of Construction Sites and Buildings Undergoing Renovation Introduction In response to increasing numbers and

More information

General Fire Code Requirements Within Commercial Tenant Spaces

General Fire Code Requirements Within Commercial Tenant Spaces FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding

More information

Notes. Material 1. Appropriate Flammable Liquids

Notes. Material 1. Appropriate Flammable Liquids 29 CFR 1910.106 Flammable Materials Flammable Liquids Preparation 1. Read Applicable Background information and related Company Policy Chapter. 2. Make Copies of this Lesson Plan for Personnel 3. Make

More information

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools APPENDIX II Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools (Prepared by Environmental Protection Department) 1. Introduction The Waste Disposal (Chemical

More information

Decree of the Ministry of the Environment on fire safety of ventilation systems

Decree of the Ministry of the Environment on fire safety of ventilation systems THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18

More information

FIRE RISK ASSESSMENT

FIRE RISK ASSESSMENT The Regulatory Reform (Fire Safety) Order 2005 FIRE RISK ASSESSMENT Employer or other responsible person Name of Premises Address Post Code Telephone N o Name of Assessor(s) Date of Assessment Date of

More information

DRY CLEANING PLANTS REQUIREMENTS FOR INSTALLATION AND OPERATION

DRY CLEANING PLANTS REQUIREMENTS FOR INSTALLATION AND OPERATION DEPARTMENT OF TRADE MERCHANT SHIPPING NOTICE NO.M.847 DRY CLEANING PLANTS REQUIREMENTS FOR INSTALLATION AND OPERATION Notice to Shipowners, Masters, Shipbuilders and Repairers 1. It has come to the notice

More information

Civil Engineering Sector Labour-Management Health and Safety Committee

Civil Engineering Sector Labour-Management Health and Safety Committee PROCEDURE FOR THE STORAGE AND HANDLING OF FUEL ON CONSTRUCTION SITES Civil Engineering Sector Labour-Management Health and Safety Committee July 2008 PROCEDURE FOR THE STORAGE AND HANDLING OF FUEL ON CONSTRUCTION

More information

IFE Level 4 Certificate in Fire Science and Fire Safety (HL)

IFE Level 4 Certificate in Fire Science and Fire Safety (HL) IFE Level 4 Certificate in Fire Science and Fire Safety (HL) Unit 2: Fire Safety Unit Reference Number: D/505/5932 Introduction This unit focuses on the prevention and detection of fire in premises and

More information

Gas and Oil Fired Space Heating

Gas and Oil Fired Space Heating January 2012 Country of Origin: United Kingdom Gas and Oil Fired Space Heating Section 1 Fixed Installations...2 Introduction...2 1. Location of Heater...2 2. Automatic Controls...2 3. Fuel Supply Gas

More information

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity? A Health and Safety Guideline for Your Workplace What is static electricity? What causes it? How is it hazardous? And, most importantly, how can it be controlled? All of these questions will be answered

More information

For use by landlords of small premises Premises Address

For use by landlords of small premises Premises Address fire risk assessment For use by landlords of small premises Premises Address FIRE RISK ASSESSMENT for use by landlords of small premises Person having control of the premises: Name of landlord (if different):

More information

Confined spaces can be deadly. What is a confined space?

Confined spaces can be deadly. What is a confined space? Confined spaces A brief guide to working safely This leaflet explains what you, as an employer, may need to do to protect your employees when working in confined spaces. It will also be useful to the self-employed

More information

For use by landlords of small premises Premises Address

For use by landlords of small premises Premises Address fire risk assessment For use by landlords of small premises Premises Address FIRE RISK ASSESSMENT for use by landlords of small premises Person having control of the premises: Name of landlord (if different):

More information

RESTRICTED ACCESS AND CONFINED SPACES

RESTRICTED ACCESS AND CONFINED SPACES Health & Safety Services Unit name goes here Safety Code of Practice 39 1 st Edition, July 2011 RESTRICTED ACCESS AND CONFINED SPACES University of Reading 2015 Page 1 Contents 1 Summary... 3 2 Introduction...

More information

BRO Roles & Responsibilities Form Page 1 of 9

BRO Roles & Responsibilities Form Page 1 of 9 BRO Roles & Responsibilities Form Page 1 of 9 This document must identify the (s) and/or the person delegated to undertake the duties listed below. These duties are required by legislation and/or Council

More information

Walking and Working Surface Checklist:

Walking and Working Surface Checklist: Walking and Working Surfaces Purpose: This information is presented to improve the level of safety in our operations, and to inform you that we will comply with the OSHA Standard 29 CFR 1910.23. Responsibility:

More information

GUIDELINE FOR SAFETY IN THE HANDLING OF FLAMMABLE LIQUIDS

GUIDELINE FOR SAFETY IN THE HANDLING OF FLAMMABLE LIQUIDS GUIDELINE FOR SAFETY IN THE HANDLING OF FLAMMABLE LIQUIDS September 2007 Replaces the July 2004 edition 1. Purpose Purpose of present Guideline is to specify conditions for the safe handling of flammable

More information

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT OVERVIEW ASSESSING THE RISK RELATIONSHIP BETWEEN FIRES AND EXPLOSIONS CLASSIFYING HAZARDOUS AREAS INTO ZONES

More information

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES Review the following information pertaining to Construction Fire Safety Planning: B.C. Building Code Sections 8.1 up to and including Subsection 8.2.3 B.C.

More information

HOT WORK PERMIT PROGRAM TRAINING. John Braun

HOT WORK PERMIT PROGRAM TRAINING. John Braun HOT WORK PERMIT PROGRAM TRAINING John Braun 1.0 INTRODUCTION 1.2 Purpose The Hot Work Permit Program has been developed for University employees that work on or around hot work activities. This program

More information

FIRE PREVENTION PLAN

FIRE PREVENTION PLAN FIRE PREVENTION PLAN 1 FIRE PREVENTION PLAN OSHA s Fire Prevention Plan regulation, found at 29 CFR 1910.38(b) and 29 CFR 1926.24, requires Northern Clearing, Inc. to have a written fire prevention plan

More information

PRECAUTIONS ON TANKER AND TERMINAL DURING CARGO HANDLING

PRECAUTIONS ON TANKER AND TERMINAL DURING CARGO HANDLING Chapter 24 PRECAUTIONS ON TANKER AND TERMINAL DURING CARGO HANDLING This Chapter provides guidance on precautions to be observed by both tanker and shore when cargo handling, ballasting, bunkering, tank

More information

ADMINISTRATIVE SERVICES MANUAL

ADMINISTRATIVE SERVICES MANUAL Purpose Responsibilities Proper Storage and use of flammable liquids can significantly reduce the possibility of accidental fires and injuries. To minimize risk to life and properly, the requirements of

More information

Safety Storage Cabinets

Safety Storage Cabinets Safety Storage Cabinets Safe storage of flammables? The workplace without a fire resistant Safety Storage Cabinet Dangers, risks and your disadvantages... STORAGE ROOM Transport/working time - Increased

More information

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Services Enclosures and Protected Shafts - Maintaining Compartmentation Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping

More information

Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012

Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012 Medicine Hat Fire Department Special Event Requirements August 202 medicinehat.ca/fire The following is a standard guide for event organizers to ensure occupant safety and compliance with the Alberta Fire

More information

Decree of the Ministry of the Environment. on fire safety of garages

Decree of the Ministry of the Environment. on fire safety of garages E4 THE NATIONAL BUILDING CODE OF FINLAND Fire safety of garages Guidelines 2005 Decree of the Ministry of the Environment on fire safety of garages Adopted in Helsinki, 22 March 2005 Pursuant to the Decision

More information

Queen's University Environmental Health and Safety

Queen's University Environmental Health and Safety April, 2009 1 SOP-Chem-08 1.0 Introduction This document is intended as a guide to the Queen s University requirements for handling and storing flammable and combustible material in non-laboratories areas.

More information

FIRE SAFETY GUIDANCE NOTE Regulatory Reform (Fire Safety) Order 2005

FIRE SAFETY GUIDANCE NOTE Regulatory Reform (Fire Safety) Order 2005 FIRE SAFETY GUIDANCE NOTE Regulatory Reform (Fire Safety) Order 2005 Number: GN66 This Guidance Note provides advice on the requirements of the Regulatory Reform (Fire Safety) Order 2005 and how to complete

More information

WORKING IN CONFINED SPACES GUIDELINES

WORKING IN CONFINED SPACES GUIDELINES WORKING IN CONFINED SPACES GUIDELINES Contents 1 Introduction... 2 2 Scope... 2 3 Definitions... 2 4 Responsibilities... 3 4.1 Permit Authoriser... 3 4.2 Permit Receiver... 3 4.3 Responsible UOW Officer...

More information

- 5 - Table1. Maximum Compartment Volumes

- 5 - Table1. Maximum Compartment Volumes - 5 - Part II - SPECIFIC REQUIREMENTS 5. Compartmentation 5.1 Every building should be divided into compartments by walls and floors to inhibit the spread of fire. 5.2 Compartment walls, compartment floors,

More information

IGEM/UP/16 Communication 1756

IGEM/UP/16 Communication 1756 Communication 1756 Design for Natural Gas installations on industrial and commercial premises with respect to hazardous area classification and preparation of risk assessments Founded 1863 Royal Charter

More information

LPG, Flammable Liquids, Toxic and Corrosive Substances

LPG, Flammable Liquids, Toxic and Corrosive Substances LPG, Flammable Liquids, Toxic and Corrosive Substances LPG, Flammable Liquids, Toxic and Corrosive Substances Safe Storage and Handling Today s focus is Dangerous substances under the Dangerous Substances

More information

EAST LINDSEY DISTRICT COUNCIL ~ RESIDENTIAL CARAVAN SITES CONDITIONS OF SITE LICENCE

EAST LINDSEY DISTRICT COUNCIL ~ RESIDENTIAL CARAVAN SITES CONDITIONS OF SITE LICENCE Residential Site Licence Conditions of Licence February 2014 EAST LINDSEY DISTRICT COUNCIL ~ RESIDENTIAL CARAVAN SITES Index of conditions CONDITIONS OF SITE LICENCE 1. Period of use 2. Bases 3. Siting

More information

OREGON FIRE CODE Interpretations and Technical Advisories

OREGON FIRE CODE Interpretations and Technical Advisories OREGON FIRE CODE Interpretations and Technical Advisories A collaborative service by local and state fire professionals, along with our stakeholders and customers, to provide consistent and concise application

More information

Building Code Clarifications - 7. Fire Resistance

Building Code Clarifications - 7. Fire Resistance Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,

More information

Portable petrol storage containers

Portable petrol storage containers Portable petrol storage containers The Petroleum (Consolidation) Regulations 2014 (PCR), which came into force on 1 October 2014, apply to the following: workplaces that store petrol where petrol is dispensed,

More information

WASTE Application Form - Dublin Waste to Energy SECTION J ACCIDENT PREVENTION & EMERGENCY RESPONSE

WASTE Application Form - Dublin Waste to Energy SECTION J ACCIDENT PREVENTION & EMERGENCY RESPONSE SECTION J ACCIDENT PREVENTION & EMERGENCY RESPONSE Describe the existing or proposed measures, including emergency procedures, to minimise the impact on the environment of an accidental emission or spillage.

More information

1.1. EMERGENCY PROCEDURE On discovering a fire or being informed of an emergency;

1.1. EMERGENCY PROCEDURE On discovering a fire or being informed of an emergency; Fire Action Plan FIRE ACTION PLAN SEStran aims to provide and maintain safe & healthy working conditions, equipment and systems of work for all our employees, and to provide such information, training

More information

A Guide to the European Standard for Safety Storage Cabinets (BS EN 14470-1)

A Guide to the European Standard for Safety Storage Cabinets (BS EN 14470-1) White Paper A Guide to the European Standard for Safety Storage Cabinets (BS EN 14470-1) Published: May 2012 Author: Greg Smith, Labtex In this Labtex White Paper: Safety Storage Cabinets Overview What

More information

Guide to Certification for Retail Hardware Stores

Guide to Certification for Retail Hardware Stores Guide to Certification for Retail Hardware Stores A Guide for the Person in Charge DECEMBER 2011 TECHNICAL GUIDE 2 Table of contents Table of contents... 2 Preface... 3 Purpose of this publication... 4

More information

Safe Use of Flammable and Explosive Substances: A Guide to DSEAR in the University. Safety and Environmental Protection Services

Safe Use of Flammable and Explosive Substances: A Guide to DSEAR in the University. Safety and Environmental Protection Services Safe Use of Flammable and Explosive Substances: A Guide to DSEAR in the University Safety and Environmental Protection Services Executive Summary 1. The Dangerous Substances and Explosive Atmospheres Regulations

More information

Fire precautions in dwellings. Private sector housing Providing homes building communities

Fire precautions in dwellings. Private sector housing Providing homes building communities Fire precautions in dwellings Private sector housing Providing homes building communities Version 3 Published by Norwich City Council August 2011 Contents Page Introduction 1 2 Types of dwellings (A) Shared

More information

Law No. (9) of 2012 Amending some provisions of Law No. (13) of 1997 Concerning the Civil Defense

Law No. (9) of 2012 Amending some provisions of Law No. (13) of 1997 Concerning the Civil Defense Law No. (9) of 2012 Amending some provisions of Law No. (13) of 1997 Concerning the Civil Defense We, Hamad Bin Khalifa Al-Thani, Emir of the State of Qatar Having pursued the Constitution, And the Law

More information

Flammable and Combustible Liquids. Slide 1 (of 23)

Flammable and Combustible Liquids. Slide 1 (of 23) Flammable and Combustible Liquids Slide 1 (of 23) Introduction The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and storage of flammable liquids

More information

Caravan Sites and Control of Development Act 1960. Permanent Residential Mobile Home Sites Licence Conditions

Caravan Sites and Control of Development Act 1960. Permanent Residential Mobile Home Sites Licence Conditions Caravan Sites and Control of Development Act 1960 Permanent Residential Mobile Home Sites Licence Conditions 1 Permanent Residential Mobile Home Site Licence Conditions Caravan Sites and Control of Development

More information

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief Dennis Fire Department Fire Prevention Mark Dellner Fire Chief FIRE SAFETY INSPECTION GUIDELINES FOR COMMERCIAL PROPERTIES (MA Fire Prevention Regulations 527 CMR, MGL Chapter 148) FIRE PREVENTION CHECKLIST-

More information

FIRE DETECTION AND ALARM SYSTEMS

FIRE DETECTION AND ALARM SYSTEMS HMO Information Sheet No 1 FIRE DETECTION AND ALARM SYSTEMS 1. Introduction When a property is in multiple occupation, the risk of fire breaking out is greater than in an ordinary single family home. Some

More information

LANCASTER UNIVERSITY. MANUAL OF SAFETY Section 29 POLICY ON FIRE RISK ASSESSMENTS

LANCASTER UNIVERSITY. MANUAL OF SAFETY Section 29 POLICY ON FIRE RISK ASSESSMENTS LANCASTER UNIVERSITY MANUAL OF SAFETY Section 29 POLICY ON FIRE RISK ASSESSMENTS 1 Introduction 1.1 The Fire Precautions (Workplace) Regulations, require the University to carry out fire risk assessments

More information

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839 AVAILABLE TO DOWNLOAD ON THE APOLLO APP a guide to Fire Alarm Systems Design BS5839 Part1:2013 The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply! What

More information

Introduction. CE marked construction products

Introduction. CE marked construction products Introduction This Technical Booklet has been prepared by the Department of Finance and Personnel and provides for certain methods and standards of building which, if followed, will satisfy the requirements

More information

The risk assessment of fire damper installations

The risk assessment of fire damper installations The risk assessment of fire damper installations June 2010 Paul White OVERVIEW OVERVIEW The purpose of this presentation is to highlight that fire dampers form a key part of the passive fire protection

More information

Fire Safety Log Book. Premises Name: Premises Address: Date From: Date To: Location of Log Book:

Fire Safety Log Book. Premises Name: Premises Address: Date From: Date To: Location of Log Book: Fire Safety Log Book Premises Name: Premises Address: Date From: Date To: Location of Log Book: CONTENTS PART 1 FIRE SAFETY ADVICE 1 PART 2 FIRE PRECAUTIONS 2 Section 1 Guidance on Fire Risks and Preventative

More information

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011, Updated March 2012 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or

More information

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression

More information

Fire Safety Risk Assessment Checklist for Residential Care Premises

Fire Safety Risk Assessment Checklist for Residential Care Premises Checklist for Residential Care Premises Name of Premises: Address of Premises: Name of Responsible Person: What area / location does the assessment cover? Does the assessment cover the whole site YES or

More information

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings Note: This information addresses complex issues in a summary fashion. Consideration should be given to the official version of the

More information

GENERAL FIRE SAFETY TERMS & DEFINITIONS

GENERAL FIRE SAFETY TERMS & DEFINITIONS UCL Fire Technical Note - TN006 Fire Safety Technical Guide GENERAL FIRE SAFETY TERMS & DEFINITIONS Reference: BS4422-2005 Fire Safety Vocabulary - for further information and definitions BS EN ISO 13943-2000:

More information

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result

More information

HOT WORK PERMIT PROCEDURES

HOT WORK PERMIT PROCEDURES COLUMBIA UNIVERSITY ENVIRONMENTAL HEALTH & SAFETY HOT WORK PERMIT PROCEDURES COLUMBIA UNIVERSITY MEDICAL CENTER February 2010 1 TABLE OF CONTENTS A. PURPOSE 3 B. SCOPE 3 C. POLICIES AND PROCEDURES 3-4

More information

REGULATORY REFORM (FIRE SAFETY) ORDER 2005. Fire Risk Assessment. 145 Drury Lane Covent Garden London WC2B 5TA

REGULATORY REFORM (FIRE SAFETY) ORDER 2005. Fire Risk Assessment. 145 Drury Lane Covent Garden London WC2B 5TA REGULATORY REFORM (FIRE SAFETY) ORDER 2005 Fire Risk Assessment 145 Drury Lane Covent Garden London WC2B 5TA Annex A (informative) Model pro-forma for documentation of the fire risk assessment for premises

More information

RESIDENTS FIRE SAFETY INFORMATION PACK

RESIDENTS FIRE SAFETY INFORMATION PACK RESIDENTS FIRE SAFETY INFORMATION PACK MARIE CURIE SCEAUX GARDENS ESTATE LONDON SE5 THE CONTENTS OF YOUR PACK Section Page No. 1. 3. Introduction Here we will explain the purpose of the Fire Safety Information

More information

An inventory of hazardous materials used in your workplace will prove useful.

An inventory of hazardous materials used in your workplace will prove useful. Introduction Fire Protection is an organized approach designed to prevent fires. In the event of a fire, a fire protection program will help prevent or minimize personal injuries, losses, and harm to the

More information

FLAMMABLE AND COMBUSTIBLE LIQUIDS

FLAMMABLE AND COMBUSTIBLE LIQUIDS GAP.8.1.0 A Publication of Global Asset Protection Services LLC FLAMMABLE AND COMBUSTIBLE LIQUIDS INTRODUCTION National Fire Protection Association (NFPA) documents describe a level of fire protection

More information

RESIDENTS FIRE SAFETY INFORMATION PACK

RESIDENTS FIRE SAFETY INFORMATION PACK RESIDENTS FIRE SAFETY INFORMATION PACK CASTLEMEAD CAMBERWELL ROAD LONDON SE5 THE CONTENTS OF YOUR PACK Section Page No. 1. 3. Introduction Here we will explain the purpose of the Fire Safety Information

More information

THERMIT WELDING (GB) LTD PROCESS MANUALS

THERMIT WELDING (GB) LTD PROCESS MANUALS THERMIT WELDING (GB) LTD PROCESS MANUALS SECTION FOUR GUIDELINES FOR SAFE OPERATION Page 1 SECTION 4 - GUIDELINES FOR SAFE OPERATION The information contained in this section is applicable to the THERMIT

More information

Workplace Health, Safety & Welfare

Workplace Health, Safety & Welfare Relevant Legislation Workplace (Health, Safety and Welfare) Regulations 1992 Construction (Design & Management) Regulations 2015 Provision & Use of Work Equipment Regulations 1998 (PUWER) Lifting Operations

More information

Electrical Classification

Electrical Classification Electrical Classification Using NFPA 70 and NFPA 499 to Classify Hazardous Locations Electrical classifications are established in accordance with the National Electrical Code, NFPA 70, also referred to

More information

OSHA Office of Training and Education 1

OSHA Office of Training and Education 1 Flammable and Combustible Liquids OSHA Office of Training and Education 1 Introduction The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and

More information