1 OPERATING INSTRUCTIONS Version 12/06 Wireless PIR motion detector FS20 PIRI-2 Item no
2 Table of contents Page 1. Introduction Prescribed use Scope of delivery Explanation of icons Safety instructions... 6 a) General information... 6 b) Batteries and rechargeable batteries Features and functions Factory setting General notes on installation Installing the FS20 PIRI a) Installation with wall bracket b) Control, display and settings c) Opening the battery compartment d) Inserting the batteries Initial operation a) Quick installation with factory settings b) Function test The FS20 address system Integrating into the address system a) Setting the house code b) Setting the addresses Setting a single address Assigning function groups and master addresses Individual settings a) Manual switching b) Activating a channel c) Setting the brightness value Saving the threshold value for one of the two channels Saving the same threshold for both channels d) Setting the on-time
3 Page e) Setting the transmission interval f) Setting the transmit command g) Setting the filter time h) Resetting the factory settings i) Programming the receiver timer Low Bat display and changing batteries Information on the range Handling Maintenance and cleaning Disposal a) General information b) Batteries and rechargeable batteries Technical specifications Declaration of conformity (DOC)
4 1. Introduction Dear customer, Thank you for purchasing this product. This product meets the requirements of both current European and national guidelines. In order to preserve this condition and ensure the safe operation of the product we kindly ask you to carefully follow these operating instructions! Please read the operating instructions completely and observe the safety and operation notes before using the product! All company names and product names contained herein are trademarks of the respective owners. All rights reserved. Should you have any further questions, please contact our technical advisory service: Germany: Tel. no.: / Fax. no.: / [email protected] Mon. to Thur. 8.00am to 4.30pm Fri. 8.00am to 2.00pm 4
5 2. Prescribed use The 2-channel PIR motion detector FS20 PIRI-2 is a component of the FS20 wireless control system. It can control up to 2 radio receivers in the FS20 system with separately adjustable criteria. The PIR motion detector registers infrared radiation (heat) of moving people and warmblooded animals (for the latter, a minimum size is required to trigger the PIR motion detector). Batteries must be used to power the device. Make sure that the product does not get damp or wet. The product is only suitable for use in dry indoor areas. Any use other than the one described above may damage the product and can also increase the risk of short-circuit, fire, electric shock, etc. No part of the product may be modified or adapted. The device may only be operated when its casing is fully closed. All the safety instructions and installation notes in this manual must be observed without fail. 3. Scope of delivery PIR motion detector FS20 PIRI-2 with installation bracket User manual 5
6 4. Explanation of icons The icon with a lightning flash in a triangle is used to alert you to potential personal injury hazards such as electric shock. The icon with an exclamation mark in a triangle points to important instructions in this user manual that must be observed. The hand symbol provides special information and advice on operating the device. 5. Safety instructions The product s guarantee becomes invalid, if the product is damaged as a result of the failure to observe these operating instructions! We do not assume any liability for any resulting damages! Nor do we assume liability for damage to property or personal injury caused by improper use or failure to observe the safety instructions. In such cases the product s guarantee becomes invalid. Dear customer, the following safety instructions are intended to protect you as well as the device. Please take time to read through the following points: a) General information If, during mounting, connection or installation you are not sure or have doubts about how to proceed, contact a skilled technician. For safety and licensing (CE) reasons any unauthorised alterations to and/or modification of the product are not permitted. Make sure that the product does not get damp or wet. It is only suitable for installation and operation in dry indoor areas. This product is not a toy and should be kept out of the reach of children. 6
7 Do not leave packaging material lying around. This may become a dangerous plaything in the hands of children. Handle the product with care; knocks, blows or even a fall from a low height can damage it. b) Batteries and rechargeable batteries Keep batteries/rechargeable batteries out of the reach of children. Make sure that the polarity is correct when inserting the batteries/rechargeable batteries. Do not leave batteries/rechargeable batteries lying around as they could be swallowed by children or pets. In such case seek immediate medical care. Leaking or damaged batteries/rechargeable batteries may cause acid burns, if they come into contact with skin. Therefore, please make sure you use suitable protective gloves. Make sure that batteries/rechargeable batteries are not short-circuited or thrown into a fire. They might explode! Never disassemble batteries/rechargeable batteries! Conventional batteries must not be recharged. They might explode! If the device is not used for a longer period of time (when stored, for example), remove the inserted batteries/rechargeable batteries to prevent them from leaking and causing damage. The PIR motion detector can be operated with rechargeable batteries. However, due to their lower voltage (rechargeable battery = 1.2V, battery = 1.5V) and lower capacity, the period of operation and range are reduced. Therefore, to ensure safe operation, please only use high-quality alkaline batteries. 7
8 6. Features and functions Detects heat motion (for example the movement of a person or an animal in front of a static background of a different temperature) and activates an alarm Range up to 12m Detection angle approx. 90 Detection area infinitely adjustable +/-45 Creep zone protection May be installed on walls or ceilings Integration in the code and addressing system of the FS20 wireless control system enables a clear boundary from adjacent running systems as well as, for instance, the control of several particular receivers 2 switching channels with separately adjustable criteria: - Each channel may be activated separately - Activation only in dark, or also whilst light - Daylight activation value freely adjustable - On-time adjustable between 0.25 seconds and 4.25 hours - Selectable receiver switching pattern (transmit command) - Transmission interval of subsequent signals of the motion detector is adjustable - Adjustable filter time for the integrated brightness sensor - Timer programming of the receiver (1 second to 4.5 hours) Optional slow-on/slow-off function for dimmer - Manual switching of the receiver via control buttons on the motion detector possible Caution! The FS20 PIRI-2 is only suitable for use in dry indoor areas! This device is not waterproof! It must not get damp or wet! 8
9 7. Factory setting The FS20 PIRI-2 is immediately ready for use and configured with the following factory default settings: Channel 1 activated (ON) Activation also in lighted areas (dawn/dusk switch function inactive) Receiver on-time triggered by movement in front of the detector: 1 minute, then load is switched off (transmit command). If further movements are registered during this minute, a new power-on command will be transmitted, at most every 24 seconds, thereby restarting the 1-minute on-time (transmission interval). Channel 2 is inactive (OFF). The terms printed here in bold are the adjustment criteria for each channel, whose programming is described separately in the following user manual. 9
10 8. General notes on installation The front coverage lenses of the FS20 PIRI-2 are supplied with 4 detection levels with 9 upper, 8 middle, 5 lower and 2 creep zone segments. This enables a detection angle of 90 to be achieved at a range of up to 12m. For additional security, the FS20 PIRI-2 is equipped with so-called creep protection so that an intruder cannot creep under the detection area of the main lens. An additional integrated lens is directed downward, under the main detection area. This mini dome lens has 17 segments which cover an area of 3.75m x 3.75m when installed at a height of 2m. In order to avoid unnecessary activation by household pets, keep them away from protected areas when possible. If this is not possible, try adjusting the height to allow the device appropriate coverage. Cover the creep zone where appropriate. Please remember that household pets may also jump on, for instance, cabinets or chairs and in so doing, arrive in the detection area. Choose a suitable installation location. To minimize false alarms, the PIR detector must not be installed where it may be exposed to direct sunlight, car headlamps or similar, nor near heat sources (for example over heaters). The detection area should be aimed at a wall or on the floor, but not directly on windows, heaters or other sources of heat. The performance of the detection is dependent upon the temperature difference between the moving object and the respective background. Detection through glass is not possible (in that case, the IR sensor only recognises the temperature of the glass). Please remember not to install the FS20 PIRI-2 directly on or near large metal objects (heating, aluminium laminated board walls, etc.) because this reduces the radio range. 10
11 9. Installing the FS20 PIRI-2 a) Installation with wall bracket The PIR motion detector is equipped with a bracket that is suitable for installation on a wall or ceiling. Because the detector may be adjusted more than 45 degrees when in the bracket, the detection area may be set at almost any angle from the wall and may also be further adjusted after installation. The ceiling installation option enables the device to be freely mounted within the room to avoid common traffic paths within the detection area, for example, in a hallway. 1 ø 5 mm 2a 20 mm ø 5 mm 2b Select an appropriate installation location for the PIR motion detector in the monitored room. Pull the wall/ceiling bracket up and off the base device of the PIR motion detector (1). Position the bracket in a suitable location on a wall or ceiling in the room. 11
12 The location of the drill holes on the wall or ceiling can be marked through the visible screw holes in the bracket. For wall installation (2a) use both holes in the wall bracket. For ceiling installation (2b) a hole needs to be drilled in the middle of the top of the bracket. Make sure that the wall or ceiling can support the device at the marked drill hole locations and avoid all electrical, gas, water and drain lines. Drill each 5mm hole at least 35 mm deep and insert 2 appropriately sized dowels. Position the wall/ceiling bracket over the drill holes and fasten it in place with the screws. 12
13 b) Control, display and settings A CH1 CH2 B C 13
14 1 1 button 2 2 button 3 3 button 4 4 button 5 DIP switch It is used to switch both channels on and off (DIP switch 1 = channel 1, DIP switch 3 = channel 2) and to switch the dawn/dusk switching function on and off (DIP switch 2 = channel 1, DIP switch 4 = channel 2). 6 LED c) Opening the battery compartment To open the battery compartment, first pull the wall/ceiling bracket in an upward direction (A). Then slide the battery compartment cover upwards (B) and remove it (C). d) Inserting the batteries The PIR detector requires 3 size AA batteries. We recommend using high-quality alkaline batteries to ensure longest possible battery life. Remove the battery compartment cover as described on the previous page. Ensure that the 4-way DIP switch settings in the centre battery compartment reflect the desired operating modes and if necessary, set them as described in section 13 (Individual settings). Insert the batteries in the battery compartment observing the correct polarity (plus/+ and minus/-, see figure on right). The battery compartment remains open. After inserting the batteries, the device needs about 75 seconds before it is ready for use. Within this time no motions will be detected. 14
15 10. Initial operation a) Quick installation with factory settings The motion detector is immediately ready for operation with the factory default settings described in section 7. The transmission signals are encrypted using a house code that is randomly assigned when the batteries are inserted and the address group 11 (control of several receivers with one transmitter possible). For the initial operation of the transmission path to the receiver, the house code and the addresses must first be transmitted to the receiver. Set the respective receiver, according to the instructions in its user manual, to the address programming mode. Press the 2 button (channel 2: button 4 ) on the keypad of the FS20 PIRI-2. The receiver s indicator LED goes out. Test the switch function by briefly pressing the 2 or 1 buttons (channel 2: button 4 or 3 ) on the FS20 PIRI-2. The receiver should switch on and off. Now the FS20 PIRI-2 is ready for operation with the factory settings. If you do not wish to set any further individual preferences, close the battery compartment. Place the device from below into the wall/ceiling bracket. It must audibly lock into place into the wall/ceiling bracket. b) Function test You can adjust the detection area of the motion detector and thereby customise it for your individual needs. For this purpose, proceed as follows: Approach the detector by crossing back and forth across the detection area. When the detector detects you, it activates the status LED and the receiver. To individually optimise the detection area, the PIR motion detector can be adjusted when in the wall/ceiling bracket. 15
16 At east one channel must be active in order to control the function and detection area of the FS20 PIRI-2 with the internal LED display. This means that at least one channel of the DIP switch must be active and not set to Switch on at twilight (DIP switch 2 or 4, setting described in section 13 b), if the brightness currently in the environment is higher than the programmed brightness threshold. Aside from this, the programmed transmission interval (factory setting: 24 seconds) of the respective channel must be observed, as this reduces repeated triggering with too short intervals. 16
17 11. The FS20 address system The FS20 address system is based on a house code which allows a number of radio-controlled systems to be operated simultaneously. 256 different addresses can be set within a house code. These addresses divide into four address types with 225 individual addresses, 15 function group addresses, 15 local master addresses and a global master address. One address from each address type can be assigned to each receiver. This means that each receiver can respond to up to four different addresses, but only ever to one address per address type. If you need a receiver to respond to more than one transmitter, you can program the transmitters to the same address or, if different transmitter address types have been set, you can program the receiver consecutively to these different addresses. The individual address types have the following functions (this explanation applies globally to the entire FS20 system and not just to individual components): Single addresses Each receiver should be set to a single address so that it can be controlled separately. Function group addresses Several receivers are defined as a functional unit by being assigned to a function group address. If, for example, all the lamps in a house are assigned to a function group, then all the lamps in the entire house can be switched on or off by pressing one button. Local master addresses Several receivers are spatially defined as one unit and controlled via the local master address. If, for example, all the receivers in a room are each allocated to a local master address, then all you need to do is press one button when leaving the room to switch off all the consumer loads in the room. Global master address Several receivers are assigned to the global master address and are jointly controlled via this address. All the consumer loads can easily be switched off simply by pressing one single button when leaving a house, for example. This address system opens up a variety of possibilities. 17
18 You can even implement access authorisations; by assigning three gates to different single addresses and a joint function group ( gates ), for example. Several people can then each be given a hand-held transmitter with a relevant single address for one garage door, while all the garage doors can be opened via a hand-held transmitter with a programmed function group address or all the doors can be automatically closed in the evening via a FS20 timer. The various address types and addresses are only set on the transmitter and these settings are transmitted to the receivers via the address assignment. 18
19 12. Integrating into the address system The house code, an address group and a subaddress are used for coding the transmitters and their individual buttons. You can also use special address group assignments to program the remote control, in this case the FS20 PIRI-2, as a local or global master. To enter the 8-digit house code, the 2-digit address groups and the 2-digit subaddresses, the 1 through 4 buttons are used (refer to figure in section 9 b) or 12 a) for assigning buttons to numbers; the status display/programmable LED is visible from the start through the main lens). This addressing makes 225 single addresses, 15 function groups, 15 local master addresses and 1 global master address available for use by the FS20 PIRI-2 within each house code. a) Setting the house code Press for 5 sec. When the batteries are first inserted, the device sets a randomly chosen house code. The house code can be changed as follows: Press buttons 1 and 3 and hold them down for 5 seconds, until the indicator LED begins to blink slowly, around once a second Blinks Enter house code (8 digits) Enter the eight-digit house code of your system using buttons 1, 2, 3 and 4. This code must be identical for all the remote control transmitters in the same wireless control system (as a precaution, make a note of this code and keep it safe), for example LED goes out The programming mode ends automatically once you have entered the eighth digit. This is indicated by the status LED going out. The house code applies to both channels of the FS20 PIRI-2 simultaneously! 19
20 b) Setting the addresses A channel s address comprises a two-digit address group and a two-digit subaddress. The address group 11 is factory set for all channels. If several transmitters are to be operated at the same time and control different receivers, then different addresses need to be set on the transmitters. 1. Setting a single address CH1 or CH2 Press for 5 sec. Blinks To set an address group and subaddress, press the respective button combination simultaneously for around 5 seconds until the indicator LED begins to blink slowly (around once a second). - for channel 1 (CH1), buttons 1 and 2 - for channel 2 (CH2), buttons 3 and Enter address group (2 digits) and subaddress (2 digits) Now enter a two-digit address group and a two-digit subaddress using the 1, 2, 3 and 4 buttons. Example: 1431 (address group 14, subaddress 31) Please note: LED goes out The programming mode ends automatically once you have entered the fourth digit. This is indicated by the status LED going out. The following address combinations are factory set to the button combinations: Button combination 1 (buttons 1 + 2): address Button combination 2 (buttons 3 + 4): address The address group 44 and the subaddress 44 both have a particular meaning (see the following section)! 20
21 2. Assigning function groups and master addresses Function groups (44xx) If you enter 44 as the address group, then the subaddress (provided this is not also set to 44; see the following section) is defined as a function group. 15 different function groups between 4411 and 4443 can then be defined. Possible are: 4411, 4412, 4413, 4414, 4421, 4422, 4423, 4424, 4431, 4432, 4433, 4434, 4441, 4442, 4443 Local master (xx44) If you only set the subaddress to 44, then this channel functions as a local master within the set address group. All receivers that are programmed with this local master address are controlled simultaneously. Possible are: 1144, 1244, 1344, 1444, 2144, 2244, 2344, 2444, 3144, 3244, 3344, 3444, 4144, 4244, 4344 Global master (4444) If you set the address group and subaddress of a channel to 44, then this channel functions as a global master. All receivers that are programmed with this global master address are controlled simultaneously. The only global master is For a large, extended system it is advisable to select addresses systematically so that you have an overview of the addresses that have already been assigned, and so that you can jointly control the programmed receivers simply and meaningfully in groups. An example is provided on the next page. 21
22 Global master address 4444 Function group 44xx, e.g ceiling lamps House code, e.g Local master address, e.g A D 1211 B C In order to distribute the address areas evenly across the house, a different address group has been assigned to each room in the house: Room A: 11, room B: 12, room C: 13, room D: 14. The awning has been allocated to the room next to it, room B. Altogether the following 15 address groups are possible: 11, 12, 13, 14, 21, 22, 23, 24, 31, 32, 33, 34, 41, 42, 43. In order to be able to separately control each receiver, you need to program each receiver to a single address. A subaddress is also required in addition to the address group that is already selected. In total, the following 15 subaddresses are possible for each address group: 11, 12, 13, 14, 21, 22, 23, 24, 31, 32, 33, 34, 41, 42, 43 In the example the awning is programmed to the single address 1211, which is comprised of the address group 12 and its subaddress
23 All the receivers in room A have also been programmed to a local master address. For the local master address 44 is always set as the subaddress, while one of the 15 local master addresses is selected via the address group. The range available for the address group is once again between 11 and 43 (11, 12, 13, 14, 21, 22, 23, 24, 31, 32, 33, 34, 41, 42, 43). In addition, all the lamps in the house can be controlled via the global master address The awning was not programmed to this address and can therefore only be controlled via its single address. The ceiling lamps in all the rooms are also combined in a function group and can therefore be jointly controlled. To select one of the 15 function groups, you need to set 44 as the address group and a value between 11 and 43 (11, 12, 13, 14, 21, 22, 23, 24, 31, 32, 33, 34, 41, 42, 43) as the subaddress. In the example the ceiling lamps have the function group address
24 13. Individual settings In addition to the factory default settings (see section 7), you can apply a variety of individual settings. The motion detector can control two different channels of the FS20 system. Each setting except house code can be individually assigned (see section 12 a). In the following instructions, the buttons in brackets apply to channel 2. a) Manual switching or 3 4 Channel 1: 1 = Off, 2 = On Channel 2: 3 = Off, 4 = On 2 4 The buttons on the motion detector can also be used for manual switching of the receiver. Press button 2 (channel 2: button 4) to switch on, button 1 (channel 2: button 3) to switch off. LED briefly blinks The status LED briefly blinks. 24
25 b) Activating a channel CH1 CH2 The activation and deactivation of each channel is set by 2 DIP switches per channel Button 1 (CH1): DIP switch 1 and 2 Channel 2 (CH2): DIP switch 3 and 4 Settings are indicated in the following table; the grey backgrounds reflect the factory default settings (section 7). DIP switch OFF ON 1 channel 1 off channel 1 active 2 channel 1 also when light channel 1 only when dark 3 channel 2 off channel 2 active 4 channel 2 also when light channel 2 only when dark Note: If only one channel is required, the second one should remain off in order to save battery capacity and to prevent unnecessary interference with other systems radio traffic within the range. 25
26 c) Setting the brightness value The brightness value that defines the switching boundary between light and dark is adjustable within a wide range. The programming must be done with the exact ambient brightness that it later will be switching, as this brightness will be saved as the threshold value. 1. Saving the threshold value for one of the two channels 1 or 3 press for 5 sec. LED lights up Press the 1 button (channel 2: button 3 ) for approx. 5 seconds, until the status LED lights up (remains lit up for the duration of the waiting time of 1 minute). Close battery compartment Place the device in the wall/ceiling bracket After 1 minute follows measurement + saving of the threshold value LED goes out Now close the battery compartment and place the device in the wall/ceiling bracket. After a minute (enough time for you to place the motion detector in the wall/ceiling bracket and switch off the lights), the current brightness is measured and saved as the threshold value. The status LED goes out. 26
27 2. Saving the same threshold for both channels 1 Press for 5 seconds LED lights up Press button 1 for approx. 5 seconds, until the status LED goes out (lights up for the total waiting period of 1 minute). 3 Within 1 minute press the 3 button for 5 seconds Close battery compartment Place the device in the wall/ceiling bracket After 1 minute the measurement and saving of the threshold value takes place. LED goes out Within one minute press and hold the 3 button for approx. 5 seconds. The waiting time of 1 minute begins again. Now you have 1 minute to close the battery compartment and place the device in the wall/ ceiling bracket. One minute after pressing button 3, the current brightness is measured and saved as a threshold value for both channels. The status LED goes out. 27
28 d) Setting the on-time The on-time of the FS20 receiver controlled components is programmable from 0.25 seconds to 4.25 hours; a continuous setting is also available. 2 or 4 press for 5 sec. blinks Press button 2 (or for channel 2, button 4) for around 5 seconds, until the indicator LED begins to blink Enter on-time LED goes out Enter the desired timer duration with 4 numbers using the buttons 1 to 4 according to the table below. When the fourth digit is entered, the indicator LED goes out. The first two digits provide the numerical value and the following two digits a multiplier with the appropriate time unit. For example (factory setting): 1 minute: Enter = 15 x 4 seconds = 60 seconds Digit combination to be entered Num. value 1st + 2nd digit Multiplier 3rd + 4th digit 11 Continuous 0.25 s s s s s s s s s = 1.07 min s = 2.13 min s = 4.27 min s = 8.53 min s = min s = min s = min s = min 28
29 e) Setting the transmission interval The transmission interval is the minimal time that must pass since the last signal was transmitted by the motion detector before being allowed, upon detection of the next movement, to transmit another signal. There are four time settings available for the transmission interval: 8, 24, 56 or 120 seconds. The factory setting is 24 seconds. 1 4 or 3 2 press for 5 sec. Press the buttons 1 and 4 (or for channel 2: buttons 3 and 2) for approx. 5 seconds, until the status LED blinks. blinks Enter transmission interval LED goes out Enter the desired time by pressing one of the four buttons according to the table below. After entering the time, the status LED goes out. Pressed button Selected transmission interval 1 8 s 2 24 s 3 56 s s 29
30 Please note: The shorter the transmission interval setting, the shorter the battery life. The transmission interval should always be shorter than the timer duration (see section 13 d) in order to prevent any down time in which the remote controlled consumer load cannot be switched on. The transmission interval factory setting is 24 seconds. The transmission interval of 8 seconds may not be set in environments where more than 180 triggering movements occur per hour. Otherwise this exceeds the maximum permitted transmission duration of the engaged radio channel per hour (duty cycle). 30
31 f) Setting the transmit command The transmit command is the radio command that is sent to the FS20 receiver upon the detection of a motion by the sensor. This can trigger various reactions from the receiver or Press for 5 sec. Press for 5 sec. Press the buttons 1, 3 and 4 (or for channel 2, the buttons 3, 1 and 2) simultaneously for approx. 5 seconds, until the status LED blinks. blinks Enter command LED goes out Give the command by entering 2 numbers according to the table below. Factory settings: 34 After entering the command, the status LED goes out. 31
32 Digit combination to be entered Transmit command 11 On (at former brightness) 12 Off 13 On (at 12.5 % brightness) 14 On (at 25.0 % brightness) 21 On (at 37.5 % brightness) 22 On (at 50.0 % brightness) 23 On (at 62.5 % brightness) 24 On (at 75.0 % brightness) 31 On (at 87.5 % brightness) 32 On (at 100 % brightness) 33 Off for the timer duration (6.4) 34 On (at former brightness) for the timer duration, afterwards OFF 41 On (at 100 % brightness) for the timer duration, afterwards OFF 42 On (at former brightness) for the timer duration, afterwards former status (feature not supported by all receivers) 43 On (at 100 % brightness) for the timer duration, afterwards former status (feature not supported by all receivers) 44 On (at former brightness) 32
33 g) Setting the filter time The filter time establishes how long the brightness in the environment must remain over the set threshold until the light status is recognised and in the switch-on at dark setting no longer reacts. The longer this time is, the longer it takes until sufficient brightness above the threshold value is recognised. The effect is that the switching becomes more sluggish or Press for 5 sec. Press for 5 sec. Press the buttons 2, 3 and 4 (or for channel 2, the buttons 4, 1 and 2) simultaneously for approx. 5 seconds, until the status LED blinks. blinks Enter command Using the buttons, enter the time according to the table below. Factory setting: 4 minutes LED goes out After entering the command, the status LED goes out. Pressed button Filter time 1 2 minutes 2 4 minutes 3 8 minutes 4 16 minutes 33
34 h) Resetting the factory settings Press for 5 sec. Simultaneously press the buttons 2 and 4, until the status LED blinks. blinks Press any button Press any button. Please LED goes out The factory default settings (see section 7) are reset and the status LED goes out. note: In case the factory settings should not be restored after pressing buttons 2 + 4, don t press any other buttons during the next minute. After one minute, the device returns to the previous individual settings, the data is not reset. When resetting to the factory default settings, a new house code is generated which the receiver will need to be associated with or the former house code must be re-entered. 34
35 i) Programming the receiver timer If the receiver that is controlled by the FS20 PIRI-2 will also be controlled by other transmitters (hand-held remote control) by the use of an internal timer, the internal timer of the receiver may be programmed as follows: The assigned button combination is pressed briefly (>1 seconds and <5 seconds) and simultaneously. This procedure is used to start, as well as to end, the timer setting measurement. The LED on the receiver blinks during the time measurement. Please also consult the corresponding receiver user manual of the receiver. The amount of time (timer duration), set according to section 13 d, has priority over the internal timer settings of the receiver when a transmission command is set between 33 and 43 according to section 13 f. To use the internal amount of time of the receiver with the FS20 PIRI-2, select a transmit command between 11 and Low Bat display and changing batteries When the batteries are low, the PIR detector FS20 PIRI-2 communicates this status on the status LED after each detected movement with a warning signal (3 triple blinks with 1 second interval). This low battery warning signal will also be sent when both wireless channels are inactive. To change the batteries, follow the instructions in section 9; observe the safety instructions in section 5. b). 35
36 15. Information on the range Ranges and interference The FS20 wireless control system (and therefore also the PIR motion detector) operates in the 868MHz range, which is also used by other radio services. Therefore devices that operate on the same or neighbouring frequencies may restrict both its operation and its range. The specified range of 100m is the free-field range, which means the range with visual contact between the transmitter and receiver. In practice however, there are ceilings, walls, garages or adjoining buildings between the transmitter and the receiver that affect and reduce the range accordingly. A repeater is available to increase the range of the FS20 system. This forwards the radio commands it receives from the FS20, which results in a greater wireless range. The actual attainable distance between the transmitter and receiver in normal operation depends very much on the installation location and the environment. As a rule when mounted in a family home, for example all components should operate faultlessly and experience no radio reception problems. Other causes of reduced ranges: All types of high-frequency interference Any buildings or vegetation Conductive metal parts that are located near the devices or within or near their transmission path, for instance, radiators, metallised insulation glass windows, reinforced concrete ceilings, etc. Influence on the radiation pattern of antennas due to the distance from the transmitter or receiver to conductive surfaces or objects (also to human bodies or the ground) Broadband interference in urban areas that reduces the signal-to-noise ratio; the signal is no longer recognised due to this noise Interference radiation resulting from insufficiently shielded electronic devices, for example, operating computers or similar 36
37 16. Handling The product is designed for use in dry and closed, indoor rooms. It must not get damp or wet. The product is not a toy and should be kept out of the reach of children. Do not install the product within the reach of children; the product contains batteries and small parts which may be swallowed. Avoid installation in dusty locations (detection power is impaired), as well as areas exposed to direct sunlight (may cause false alarms). Even direct sunlight on monitored surfaces can lead to false alarms or other disturbances. Detection through glass is not possible as the IR sensor only recognises the temperature of the glass. 17. Maintenance and cleaning The product requires no servicing except for battery replacement. Any repairs should be carried out by a skilled technician or professional workshop! Clean the product with a soft, clean, dry and lint-free cloth. To remove heavier dirt, use a cloth which is slightly moistened with lukewarm water. Do not use any solvent-based cleaning agents as these may damage the plastic casing. 37
38 18. Disposal a) General information Do not dispose of electric and electronic products via the household rubbish. When the product is no longer usable, dispose of it in accordance with the applicable statutory regulations. b) Batteries and rechargeable batteries As the consumer, you are legally obliged to return all your used batteries and rechargeable batteries. Do not dispose of your used batteries via the household rubbish! Batteries/rechargeable batteries containing harmful substances are marked with the following icons, which alert you to the fact that disposal via the household rubbish is prohibited. The identifiers for the respective heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead (identifier is on the battery/rechargeable battery, for example, under the rubbish bin icons on the left). You can return your used batteries/rechargeable batteries free of charge to any authorised disposal station in your area, in our stores or in any other store where batteries/rechargeable batteries are sold. By doing so you comply with your legal obligations and also make a contribution to environmental protection. 38
39 19. Technical specifications Operation:... passive IR sensor Sensor characteristic: Main lens: PIR sensor range:... up to 12m Detection angle:... approx. 90 Creep zone protection: PIR sensor range:... up to 4m Detection angle:... approx. 43 Pivoting range:... approx. ±45 Number of FS20 channels:... 2 Batteries:... 3 x AA batteries (LR06) Battery life:... approx. 3 years, dependent upon settings Frequency: MHz Wireless range:... up to 100m (free-field, see section 15) Dimensions (Ø x H):... 55mm x 132mm 20. Declaration of conformity (DOC) We, Conrad Electronic, Klaus-Conrad-Straße 1, D Hirschau (Germany), hereby declare that this product complies with the fundamental requirements and other relevant regulations of directive 1999/5/EG. You can find the declaration of conformity for this product at 39
40 CONRAD IM INTERNET % recycling paper. Bleached without chlorine. Imprint These operating instructions are published by Conrad Electronic SE, Klaus-Conrad-Str. 1, D Hirschau/Germany. No reproduction (including translation) is permitted in whole or part e.g. photocopy, microfilming or storage in electronic data processing equipment, without the express written consent of the publisher. The operating instructions reflect the current technical specifications at time of print.we reserve the right to change the technical or physical specifications. Copyright 2006 by Conrad Electronic SE. Printed in Germany.
Surface-mounted remote switch FS20 SA
OPERATING INSTRUCTIONS Version 07/07 Surface-mounted remote switch FS20 SA Item no. 62 30 07 Introduction Dear customer, Thank you for purchasing this product. This product meets the requirements of both
Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2
Installation and Operating Manual p. 23 Radio push button 2 channel: HM-PB-2-WM55-2 1. English edition 10/2013 Documentation 2013 eq-3 Ltd., Hong Kong All rights reserved. No parts of this manual may be
WEATHER STATION Instruction Manual Cat. No. 35.1115.IT
WEATHER STATION Instruction Manual Cat. No. 35.1115.IT Thank you for choosing this wireless weather station from TFA. BEFORE YOU USE IT Please be sure to read the instruction manual carefully. This information
Operating Manual Remote Cost Control Monitor
Operating Manual Remote Cost Control Monitor INTRODUCTION: Congratulations on purchasing the Remote Cost Control. This is a state-of-the-art power monitoring socket that is highly accurate and easy to
Wireless Home Security Alarm System AM 500
Wireless Home Security Alarm System AM 500 12 MONTH GUARANTEE Installation & Operating Instructions INTRODUCTION The AM500 is a simple self-contained alarm system. It protects the home by sounding a siren
MEMO ALARM CLOCK Operating Manual
MEMO ALARM CLOCK Operating Manual INTRODUCTION Congratulations on purchasing this state-of-the-art Alarm clock with radio controlled time. The operation of this product is simple and straightforward and
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
Home Security Alarm System
Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better
User Guide. Model: MAS-WA-SYS
User Guide Model: MAS-WA-SYS CONTENTS Section : Getting started... 4. General system overview. Introduction to the system.3 Items included with the system.4 Introduction to the Wireless Alarm Panel.5 Introduction
HWS100 Wireless Home Security System
4902000 HWS100 Wireless Home Security System Owner s Manual WARNING: Security system devices cannot compensate for loss of life or property. Company is not responsible for any loss or intrusion. CONTENTS
WIRELESS HOME ALARM SYSTEM (WHA1)
WIRELESS HOME ALARM SYSTEM (WHA1) IMPORTANT : PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS ALARM SYSTEM. SAFETY Please note: Before you start to install this alarm, we
THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions
THE NEW GENERATION IN TECHNOLOGY NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking Operating Instructions Table of Contents Important Safeguards... 3 Parts... 6 Controls... 6 To Set Up... 7 ipod/iphone
BEL-AIR WIRELESS THERMO-HYGROMETER Instructions manual Cat. No. 30.3045.IT
BEL-AIR WIRELESS THERMO-HYGROMETER Instructions manual Cat. No. 30.3045.IT Thank you for choosing this wireless thermo-hygrometer from TFA. BEFORE YOU USE IT Please be sure to read the instruction manual
Passive Infrared Sensor Alarm
49-329.fm Page 1 Wednesday, August 18, 1999 4:23 PM Cat. No. 49-329 OWNER S MANUAL Please read before using this equipment. Passive Infrared Sensor Alarm with Keychain Remote 49-329.fm Page 2 Wednesday,
ST815 Illumination Sensor with LCD
ST815 Illumination Sensor with LCD The Illumination Sensor with LCD (refer to as Illumination Sensor hereafter) is a Z-Wave TM enabled device which is fully compatible with any Z-Wave TM enabled network.
Solar Weather Station Model: BAR806 / BAR806A
Solar Weather Station Model: BAR806 / BAR806A EN CONTENTS USER MANUAL Overview... 2 Front view... 2 Back view... 3 Remote sensor... 3 Getting started... 3 Solar panel... 3 Insert batteries... 4 Remote
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
Single Day Alarm Clock with. Bluetooth and USB Play-through
Single Day Alarm Clock with Bluetooth and USB Play-through MODEL : BSC 200 READ THIS INSTRUCTION MANUAL BEFORE OPERATING THE APPLIANCE. SAVE THIS MANUAL FOR FUTURE REFERENCE. TABLE OF CONTENTS IMPORTANT
Atomic Alarm Clock Instruction Manual
Atomic Alarm Clock Instruction Manual Introduction: Congratulations on purchasing the Atomic Alarm Clock with WWVB Radio controlled time, calendar, 12/24 hours display, time zone with US map, indoor temperature
90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F
90 Degree PIR Wireless Security Sensor Installation Instructions 5420/90F Copyright Clipsal Australia P/L 2007. All rights reserved. Clipsal is a registered trademark of Clipsal Australia Pty Ltd. The
Atomic Alarm Clock model 13131W2
Instruction Manual Atomic Alarm Clock model 13131W2 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Clock Setup... 4 Atomic Clock... 5 Set
Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC
Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC Please do not return this item to the store. If you have any questions, please contact
WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054
WIRELESS ALARM KIT COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS Model Number: IT214054 INSTRUCTION MANUAL Warranty Details/Support This product is warranted against defects for a period of One year if the
2013 VTech Printed in China 91-009656-000 US
Rechargeable Power Pack User s Manual 2013 VTech Printed in China 91-009656-000 US INTRODUCTION The Rechargeable Power Pack makes it easier than ever to keep the InnoTab 3 or InnoTab 3S charged and ready
Weather Radio Alarm Clock
1200093 User s Guide Weather Radio Alarm Clock Thank you for purchasing your Weather Radio Alarm Clock from RadioShack. Please read this user s guide before installing, setting up, and using your new weather
IN-OUT Thermometer with Cable Free Sensor and Clock
IN-OUT Thermometer with Cable Free Sensor and Clock MODEL: RAR232 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RAR232 In-Out Thermometer with 433MHz cable free sensor and calendar
Six-defense zone Display Alarm System. User Manual
Six-defense zone Display Alarm System User Manual Feature 1. Anti-interfere function. When someone interferes it with same frequency, the control unit will activate siren to alarm. 2. Support anti-decode
LCD Display. Function keys. Stand. Adapter socket
433 MHz RADIO CONTROLLED PROJECTION ALARM CLOCK Instructions manual INTRODUCTION: Congratulations on purchasing this innovative 433MHz Projection alarm clock which displays indoor temperature and humidity
Wireless Auto-dial Intruder Alarm System
Wireless Auto-dial Intruder Alarm System User Manual User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Features and Function 1.
musical auto mirror day & night light Control Panel Features Mirror Features Front View Mirror Features Rear View B C Remote Receiver C
Control Panel Features A Power, Low/High Volume Switch Note: The dual-mode night light and music can only be activated by pressing the buttons on the remote. A Mirror Features Front View B Dual-Mode Night
The Weather Station. Hanging Hole. LCD Display Battery Cover. Function Keys. Detachable Stand
WIRELESS 433 MHz WEATHER STATION Instructions Manual INTRODUCTION: Congratulations on purchasing this Weather Station with wireless 433 MHz transmission of outdoor temperature and display of indoor temperature
WIRELESS 433 MHz TEMPERATURE STATION Instruction Manual Cat. No. 30.3015
WIRELESS 433 MHz TEMPERATURE STATION Instruction Manual Cat. No. 30.3015 Thank you for choosing this wireless temperature station from TFA. BEFORE YOU USE IT Please be sure to read the instruction manual
GB Instruction Manual. www.quantys.de
GB Instruction Manual www.quantys.de GB Instruction manual Solar RADIO-CONTROLLED ALARM CLOCK With analogue alarm time setting Safety instructions - Swallowing batteries can be life-threatening. Therefore,
CAD-05 Kit GSM Auto Dialer. Owner s Manual
CAD-05 Kit GSM Auto Dialer Owner s Manual CAD-05 Kit Manual.indd 1 Warnings: This device complies with Part 15 of the FCC rules, Operation of this device is subject to the following conditions: 1. This
Owner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating
MAKING MORN LIVING POSSIBLE Danfoss heating living connect Installation and User Guide Contents 1.0 System overview... 3 2.0 Overview of display and control buttons... 3 3.0 Installation - step by step...
CL90i. 77-021 Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser
3 - Beam Self-Leveling Cross Line Laser CL90i 77-01 Please read these instructions before operating the product Self-Leveling GB D F I E PT NL DK SE FIN NO PL GR CZ RU HU SK SI BG RO EE LV LT Contents
REMOTE TERMOMETER TE 219 LED USER MANUAL
INTRODUCTION REMOTE TERMOMETER TE 219 LED USER MANUAL Thank you for purchasing this unit with indoor thermometer, wireless thermometer sensor and radiocontrolled clock. This device is also equipped with
www.somfy.com Telis 4 Soliris RTS Operating and installation guide Ref.5054466A
www.somfy.com Telis 4 Soliris RTS Operating and installation guide Ref.5054466A Contents 1. Brief introduction to the Telis 4 Soliris RTS remote control 3 1.1 What is the Telis 4 Soliris RTS for? 3 1.2
MOBILE CALL GSM alarm system
MOBILE CALL GSM alarm system User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. - 1 - Catalogue: Function Introduction 2 SMS Number
PhoneWatch Smart Security System User Manual - Domonial
PW0002 10/13 Customer Support: 1850 753 753 PhoneWatch Ltd., Unit 3/4, Sandyford Park, Burton Hall Rd, Sandyford Industrial Estate, Dublin 18. Email: [email protected] PhoneWatch Smart Security System
Atomic Projection Alarm with Indoor and Outdoor Temperature
Model: WS-5220U-IT Instruction Manual DC: 082415 Atomic Projection Alarm with Indoor and Outdoor Temperature SNOOZE button Time, Alarm + WWVB Icon Projection arm Indoor Temp., Outdoor Temp. Battery Compartment
COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions
COMPUTHERM Q7 Programmable, digital room thermostat Operating Instructions GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q7 type switched-mode room thermostat is suitable to regulate the overwhelming
MOBILE CALL GSM Alarm System User s Manual
MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction Alarm Host Diagram
Transmitter Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso
Transmitter Speed 1 9 3 5 0 Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso E L S Tr a n s m i t t e r S p e e d M a n u a l 0 2. 0 2. 2 0 1 0 / / 7
Wireless Alarm system s manual
MOUNTVIEW TECH AUSTRALIA PTY LTD Wireless Alarm system s manual ADS A180 Series ADS Security 1/11/2011 1. Before You Begin For your safety and the safety of others, and to ensure that you get the most
GSM Home Alarm System User Manual. http://www.usmartbuy.com
GSM Home Alarm System User Manual http://www.usmartbuy.com 1 1. Factory default Normally, all sensors in the big box have been coded (learnt) to the control host Operation Password: 0000 Long-Distance
Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location
45131 Wireless Alarm System Window/Door Sensor User s Manual Choice ALERT Control all Sensors & accessories from one location Table of Contents Important Safeguards 4 Introduction 5 Installation 6 Assigning
Business/ Home GSM Alarm System
Business/ Home GSM Alarm System BUSINESS/HOME GSM ALARM SYSTEM POWER STATUS RECORD SIGNAL User Manual Profile For a better understanding of this product, please read this user manual thoroughly before
BUSINESS. Elektronisches Türschloss. Installation and User Manual. www.burg-waechter.de. Ingeniously safe. Ingeniously simple.
Elektronisches Türschloss BUSINESS Set 5011 PINCODE Set 5012 FINGERSCAN Set 5013 E-KEY Ingeniously safe. Ingeniously simple. BA/MA TSE Set 5000 dp/fsc 04/2012 Installation and User Manual BURG-WÄCHTER
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
Getting started with
PART NO. CMA113 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption monitoring single phase for homes and some smaller light commercial
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
Model: 616-146v2 Quick Setup Guide DC: 071015 Atomic Projection Alarm with Indoor and Outdoor Temperature
Model: 616-146v2 Quick Setup Guide DC: 071015 Atomic Projection Alarm with Indoor and Outdoor Temperature Snooze/Backlight BUTTONS Time, Alarm with Snooze, & Calendar Projection Arm Rotates 180 Indoor/Outdoor
PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.
WIRELESS AUTODIAL HOME ALARM SYSTEM AM2000 Instructions for use Important! Please read these instructions carefully. IMPORTANT 1 IDENTIFICATION PLEASE CONTACT BEFORE RETURNING THIS PRODUCT TO THE RETAILER
Introduction Ericsson Handheld Telephone 1341-B
Ericsson Handheld Telephone 1341-B 2 Contents General 5 The Mobile Telephone Network 6 Base Station and Cell 7 Radio Channels 7 Radio Coverage 8 Transmission Control and Communication 9 Quality Control
How To Program An Autodialer
GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second
Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION
Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION FRONT VIEW SENSOR TX141TH-Bv2 LED TX Sensor Battery Cover Sensor Battery Compartment 2 AA Buttons Battery Compartment 3 AAA BACK VIEW Battery
Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!
BeoLab 6002 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
BeoLab 4000 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified
When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.
BeoLab 11 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE
MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE OPERATING MANUAL HAA51 PASSIVE INFRARED INTRUDER DETECTOR INTRODUCTION HAA51 Passive Infrared
QFP910. Water detector. Building Technologies. CE1N2732en. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location
Wireless Alarm System Wireless Keypad User s Manual 1 2 3 4 Choice ALERT Control all sensors, accessories and remote transmitters from one location Table of Contents Important Safeguards 4 Introduction
Wireless Home Security System Product Manual (Model #80355)
Wireless Home Security System Product Manual (Model #80355) Installation Instructions During set-up, if no key is pressed for 15 seconds it will come out of the setup mode and you will have to start over.
RADIO CONTROLLED DIGITAL CLOCK MODELS 88905 / 88906
RADIO CONTROLLED DIGITAL CLOCK MODELS 88905 / 88906 QUICK SETUP GUIDE IMPORTANT! INSTALL BATTERIES IN THE OUTDOOR TRANSMITTER BEFORE INSTALLING BATTERIES IN THE RADIO-CONTROLLED CLOCK. ALKALINE BATTERIES
MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions
MAKING MODERN LIVING POSSIBLE living connect Installation and User Guide Danfoss Heating Solutions 2 living connect Thank you for buying a Danfoss product Danfoss Heating Solutions 3 Contents 1. System
RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G
Auto-Levelling Rotary Laser Level RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G 77-496 / 77-429 / 77-439 / 77-497 / 77-427/ 77-441 Please read these instructions before operating the product Auto-Levelling
Wireless Alarm System. Silent Alert. User s Manual. Choice ALERT. Control all Sensors & accessories from one location
45137 Wireless Alarm System Silent Alert User s Manual Choice ALERT Control all Sensors & accessories from one location Table of Contents Important Safeguards 4 Introduction 4 Adding a Silent Alert to
Stove Guard Kit User Manual
Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent
PSTN Home Alarm System
PSTN Home Alarm System User Manual Model: PST-TEL99E Please read this user guide carefully before operation and installation. Contents 1. Product Overview... - 3-2. Main Function & Features... - 3-3. For
WS-9005TWC 915MHz WIRELESS RAIN GAUGE INSTRUCTION MANUAL
WS-9005TWC 915MHz WIRELESS RAIN GAUGE INSTRUCTION MANUAL CONTENTS 03 introduction 03 features 04 setting up 06 function keys 06 operations 07 mounting 08 maintenance 09 specifications 09 liability disclaimer
500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location
Wireless Alarm System Panic Button User s Manual Choice ALERT Control all sensors, accessories and remote transmitters from one location Table of Contents Important Safeguards 4 Introduction 5 Activating
User s Manual. Copyright 2014 Trick Technologies Oy
User s Manual Copyright 2014 Trick Technologies Oy Catchbox Pro Module Catchbox Cover Contents 1 Safety Instructions...4-5 2 Quick Start... 6-15 3 Product Description... 16-18 Overview...16 Compatibility...17
User s manual FLIR VP50/VP52 Non-contact AC voltage detector
User s manual FLIR VP50/VP52 Non-contact AC voltage detector User s manual FLIR VP50/VP52 #T559851; r. AD/ 9134/9134; en-us Table of contents 1 Disclaimers... 1 1.1 Copyright... 1 1.2 Quality assurance...
User Guide Nokia Portable Wireless Charging Plate DC-50
User Guide Nokia Portable Wireless Charging Plate DC-50 Issue 1.1 EN User Guide Nokia Portable Wireless Charging Plate DC-50 Contents For your safety 3 About your accessory 4 Keys and parts 5 Top up your
Alarm Clock USER GUIDE
Alarm Clock USER GUIDE Jazwares, Inc. 2010 1 CONTENTS Please read the instructions along with the alarm clock carefully before you use it, so that you can operate it conveniently. WELCOME, Safety Tips
GSM AD05 Slave GSM Auto Dialer- Instruction Manual
GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
BeoLab 7-6 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified
720r Addendum: Siting the 720r
720r Addendum: Siting the 720r UK 1 Cooper Security Limited 2013 Every effort has been made to ensure that the contents of this leaflet are correct. However, neither the authors nor Cooper Security Limited
Quick start: Panic Watch EU
Quick start: Panic Watch EU Technical specs Normal operating voltage Frequency range Wireless Range 1x CR2032 3V battery 868.42 MHz Min 150 meters in a mesh network Basic operations - The Panic Watch can
How To Control A Marmitek X10 With A Remote Control
SAFEGUARD TOTALGUARDtm ENGLISH USER S GUIDE 20071 / 20070228 SAFEGUARD TM / TOTALGUARD TM ALL RIGHTS RESERVED 2007 INDEX Introduction Safety warnings BASIC OPTIONS 1. Your Marmitek surveillance system
Intelli-Time Alarm Clock model 13027
Instruction Manual Intelli-Time Alarm Clock model 13027 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Clock Setup... 4 Intelli-Time Clock...
DAB & FM RADIO Installation Manual
Size: 105x145mm 105g copper paper DAB & FM RADIO Installation Manual Model: 10798 10799 10800 10801 Thank you for purchasing this AGK DAB/FM radio. Please read the instructions and warnings carefully before
WEATHER STATION Instruction Manual Cat. No. 35.1111.IT
WEATHER STATION Instruction Manual Cat. No. 35.1111.IT Thank you for choosing this wireless weather station from TFA. BEFORE YOU USE IT Please be sure to read the instruction manual carefully. This information
Understanding Alarm Systems
Understanding Alarm Systems A false alarm occurs when an alarm signal designed to elicit an immediate emergency Law Enforcement, Fire, or Medical response is activated, when in fact no emergency exists.
WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential and Small Business Control Panels
www.adt.com WIRELESS SENSOR For Safewatch Residential and Small Business Control Panels Your ADT Safewatch QuickConnect, SafeWatch 3000 or Vista Series residential or small business security system may
TX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
PiSector Home security systems
PiSector Home security systems User Manual (ALM-S02) Read manual fully before use. PiSector Inc., USA, www.pisector.com Thank you for purchase this alarm system, For proper use and your safety, please
Rousseau 10. User Guide
Rousseau 10 User Guide Base station overview ➀ LED signals White, permanent light: - Base station ready, you can register a handset Slow flashing white light: - Paging call in progress - Active call (you
Quick Start Guide Vodafone Business Connect
Quick Start Guide Vodafone Business Connect Safety instructions Read the following instructions carefully. Failure to comply with these instructions can be dangerous and/or illegal. You are solely responsible
WALL MOUNTED SPLIT TYPE AIR CONDITIONER
WALL MOUNTED SPLIT TYPE AIR CONDITIONER MANUAL 8 OM-G12-ACSON CONTENTS - Operating Guide page 1 - G12 Remote Controller Indication page 2 - Indicator Lights page 4 - Installation of Aroma page 5 - Auto
Short Range Wireless Switch System Handheld 8 Installation and Operations Guide
Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
Atomic Projection Alarm Clock model 13021
Instruction Manual Atomic Projection Alarm Clock model 13021 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Clock Setup... 5 Atomic Clock...
BSCAN DW VOX SAVE BEEP CHANNEL CALL VOX
The World in Communication Content 2 ALAN 441 transceivers 2 1 user instructions 8 CHANNELS PMR446 TRANSCEIVER Congratulations on your purchase! ALAN 441 is a new generation PMR 446 transceiver which may
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
NOQ_NQ-9121 Z-Wave Data Logger for Gas Meters Firmware Version : 2.55
NOQ_NQ-9121 Z-Wave Data Logger for Gas Meters Firmware Version : 2.55 Quick Start S This device is a Z-Wave Sensor. Inclusion and Exclusion are confirmed by triple clicking the Z-Wave button on the device.