Project description PRISME 2 Swedish Project Validation and use of test results for under- ventilated fire scenarios
|
|
|
- Peter Black
- 9 years ago
- Views:
Transcription
1
2
3
4
5 Project description PRISME 2 Swedish Project Validation and use of test results for under- ventilated fire scenarios Background PRISME 1 The first PRISME project [1] was an OECD/NEA project with participation of the following countries: Belgium Canada Finland France Germany Japan Netherlands Republic of Korea Spain Sweden. United Kingdom United States The budget of the project was 7 M and the project time of the project was from January 2006 to June The major PRISME project financed fire tests at IRSN (France). A project and management group was established by means of the contract and had meetings at least twice a year. During the meetings the technical content and scope of the project was discussed. PRISME is the French acronym for Propagation de l Incendie lors de Scénarios Multilocaux Elémentaires which is translated to Fire Propagation in Elementary Multi-room Scenarios. The project mainly aims on studying smoke and hot gases propagation in full scale, well confined and mechanically ventilated fire compartments. The PRISME project consisted of a series of fire and smoke propagation tests in a dedicated facility at the French Institut de radioprotection et de sûreté nucléaire (IRSN) centre at Cadarache, France. The facility is used to investigate room-to-room heat and smoke propagation, the effect of network ventilation and the resulting thermal stresses to sensitive safety equipment of such room configurations. The project (citation from reference [1]) aimed to provide such critical information as the time that elapses before target equipment malfunctions and to qualify computer codes modelling heat and smoke propagation phenomena. The objective was to answer questions concerning smoke and heat propagation inside an installation, by means of experiments tailored for code validation purposes. Several propagation modes were being studied: through a door; along a ventilation duct that crosses the room containing the fire and that ventilates an adjacent room; along a ventilation duct when flow is reversed within and through leakages between several rooms.
6 Apart from the project, which incorporated the fire test, a separate project dealing with validation was conducted, the so-called benchmark project. This project was not covered by a contract but was conducted based on national resources. It was in this project that the major activities of the previous Swedish PRISME project, sponsored by NBSG and Brandforsk, could be situated. NBSG is the national fire safety group for nuclear power plants consisting of the Swedish Nuclear Power plants in Sweden (Ringhals, Oskarshamn and Forsmark), The Swedish Regulator SSM and the Swedish Nuclear Fuel and waste Management (SKB). The PRISME 1 project, both at national and international level, is now in its reporting phase but the new project PRISME 2 has already started from July 1 st A number of publications are available for results of the overall PRISME project [2] [3]. The major result from the benchmark exercise in PRISME1 can be found in annex 2 and is part of a joined publication [4][7][8]. With respect to the Swedish PRISME project a summary of the results can be found in the article presented at the SMIRT conference, which can be found in annex 1. The major achievements of the Swedish PRISME project can be summarised as follows: LTH participated successfully in the benchmark exercises and was part of the joined publication. The results of this benchmark showed the limitation of previous FDS versions for ventilated compartment fires where interaction between fire and ventilation are important. LTH did then a number of successful validations of the new ventilation module developed by NIST. This will create a lot of possibilities for simulation of fire and ventilation flows. LTH developed an empirical model for prediction temperature of the smoke gases in a room adjacent to the fire room. This was done by numerical experiments combined with a validation by means of the PRISME results and other large-scale tests. The model worked well for ventilated fires but from the PRISME database it could see that under-ventilated fires do not follow this trend. PRISME 2 During 2009 and 2010 discussions were made within the project group to work towards an extension of the project. The whole project plan and description is given in Annex 3. The programme of the new experimental PRISME 2 project has been elaborated on the basis of the needs expressed by all members of the PRISME Project and of the conclusions of the Expert Meeting of the OECD PRISME 2 Project held in February In particular, the members responded that the Project focus will be on fire scenarios of interest in nuclear power plants including multi-compartment fires, ventilation systems, real fire sources with flame propagation, under-ventilated combustion regime and extinction systems. The partners replies converged towards the three main topics of interest: smoke and hot gas propagation through a horizontal opening between two superposed compartments, fire spreading on real fire sources such as cable trays and electrical cabinets and fire propagation from a fire source to another, and fire extinction studies of the performance of various extinguishing systems. Similarly to PRISME 1 there will be also a number of benchmark exercises performed in a benchmark group. At this stage it is even planned to conduct an open simulation of one of the PRISME project. This information is important to obtain more data in order to determine the uncertainty of CFD simulation tools.
7 Objectives The main scope of the Swedish PRISME 2 project is to assess and determine the CFD tools used for fire safety evaluations and to implement the test results from the PRISME project for Swedish applications not only in nuclear power plants but also in buildings and constructions where similar fire scenarios will occur as in the PRISME project. The objectives are covering three parts: 1. Validation of CFD tools in the scenarios within the PRISME project (mainly FDS but possibly also other CFD tools e.g. Ansys-CFX, Firefoam, ISIS depending on evaluation of the packages). This will be limited to the scenarios and exercises within the PRISME project and will not be an overall validation. In cases where no other experience at LTH is available, other validations, using standard and basic benchmarks, need to be conducted. 2. Dissemination of the test results within the PRISME project to the Swedish fire community by reporting to the reference group in the project, presenting the results at the national seminars and meetings and finally by writing scientific articles. 3. Participate in the benchmark group meetings and other PRISME meetings. Project Plan The following activities are planned over a five years period: 1. Use of test results for Swedish Applications. 2. Validation of Ventilation module in FDS with PRISME results. 3. Investigation of other CFD software packages 4. Participation in BE exercises and set-up of a Swedish benchmark exercise. 5. Development and validation of a pool fire model in FDS for enclosures. 6. Dissemination of project results. The project is divided in 5 work packages: 1. Use of the test results for Swedish Applications The PRISME test results are reported by IRSN, France and are part of their reporting obligations to the PRISME consortium. However these results need to be translated for Swedish applications. In this work package this information will be gathered. In this work package participation to the PRISME meetings is included. 2. Validation of CFD packages by means of the PRISME 2 test results. In this work package the validation exercises will be performed. The following activities will take place: Validation of Ventilation module in FDS with PRISME results.
8 In this activity LTH will further validate the newly developed ventilation module in FDS. This validation will be important for further use of the module in nuclear power plant applications and also building and transport applications. Investigation of other CFD software packages This activity will look into other CFD packages and how they can be used for performance based design. Possible candidates of software are FireFoam, ISIS and ANSYS- CFX. Choice of the software will depend on availability of resources, both personal and software/hardware. Participation in BE exercises and set-up of a Swedish benchmark exercise In this work package LTH will take part of the benchmark exercises in the benchmark of the PRISME 2 project. At the moment both blind and open simulation are scheduled and proposed. Especially the blind simulation are important as they will give an important input with respect to uncertainty of simulations due to e.g. unknown pre-knowledge and user effect. This has been clearly demonstrated in a number of previous projects [5] [6]. If blind simulation would not be possible due to insufficient interest in the PRISME OECD NEA consortium, LTH will organise a national blind simulation in which other universities, research institute and consultants can participate. 3. Development and validation of a pool fire model in FDS for enclosures. The scope of the WP is to provide improved tools for deterministic evaluation of the risk for loss of functional performance in redundant systems critical for shut down of the reactor within PSA analyses. The improved tool will contain an advanced pool fire model, which takes into account all aspects of the enclosure (geometry, properties, ventilation) and fuel (amount, type, surface area, thermal boundaries). Both literature study, development of a pool fire model and validation of the model will be conducted in this work package. This WP is part of an approved NKS project with partners from VTT, Haugesund University College and Ringhals AB. NKS is the Nordic Nuclear Safety research foundation ( The first year report has been approved by NKS [9]. 4. Dissemination of project results. In this work package reporting of the interpretation of the test results as well as the validation exercises will be done. The dissemination will be done by: participation at conferences (e.g. NBSG yearly meeting) seminars (internationally e.g. yearly SMIRT seminar), scientific articles (published as conference proceedings or peer-review articles) SSM or LTH reports 5. Participation in OECD NEA PRISME 2 project This work package does not contain activities from LTH or requires financing from Brandforsk but it contains the contribution of Sweden to the PRISME OECD NEA project, which is financed by NBSG. In NBSG all three nuclear
9 Time plan power plants are members as well as SKB and SSM. The WP is included in this proposal to give a total overview of the Swedish part of the research project. The time plan for the project is from July 1st 2011 until July 1st The Brandforsk project will start from June 1 st 2012 and end on January 1 st This will allow for a full reporting of the project to Brandforsk. Budget The overall project budget for the Swedish part of the PRISME 2 project is 6350kSEK. A breakdown can be found in the table below. The budget for the Brandforsk project is 250 ksek per year, totally resulting in 1250 ksek over a five years period. The budget is divided as follows over the work packages where WP 3 is the NKS project WP 5 is the contribution to the OECD NEA project. Work Package Budget Requested financing Brandforsk 1. Use of test results 250 ksek 250 ksek 2. Validation of CFD models 750 ksek 750 ksek 3. Development and validation pool fire model 1100 ksek (990 kdkk) from NKS 0 ksek 4. Dissemination 250 ksek 250 ksek 5. Contribution to PRISME 2 OECD/NEA project 4000 ksek from NBSG 0 ksek Total Budget Swedish Part 6350 ksek 1250 ksek Total PRISME 2 project ksek 0 ksek Additional committed resources The Swedish part of the OECD/NEA PRISME 2 project, which finances the experiments at IRSN, is financed by NBSG (National Fire Safety group for nuclear power plants). The Swedish part is 400 keuro (approximately 4 MSEK) for the whole 5 years period. Through the NKS project additional resources are available for the Swedish Part of PRISME 2, which focuses another aspect of CFD modelling, namely the development and validation of a pool fire model for enclosures. The overall NKS project has a budget
10 of 990 kdkk (approximately 1100 ksek) for a three-year period. The LTH budget in this project is 450 kdkk (approximately 500 ksek). The budget in this application would support the important validation and dissemination activities. It is also important to note that the overall value of the PRISME 2 project is about 70 MSEK (7 MEuro) Project group The project group is composed as follows: Patrick van Hees, professor at Lund University, Department of Fire Safety Engineering and Systems Safety, project leader, responsible for WP 1 and 3, project leader for WP4. Jonathan Wahlqvist, PhD student at Lund University, Department of Fire Safety Engineering and Systems Safety, responsible for WP 2 Simo Hostikka, VTT Finland (WP 4 as part of the NKS project) Bjarne Husted, Haugesund University College (WP 4 as part of the NKS project) Tommy Magnusson (WP 4 as part of the NKS project and Swedish representative in the OECD NEA project, responsible for WP 5) Fredrik Jörud (WP4 as part of the NKS project) At the moment, the following countries will participate in the project group for the PRISME2 project: Belgium Canada Finland Germany Japan Spain Sweden Collaboration between the partners of the PRISME OECD/NEA project and the Swedish project group will be envisaged during the whole project. Also cooperation within the NKS project will be obtained. Amongst the participants there is also Simo Hostikka, one of the FDS developers. This will give the project a direct connection to the FDS development group.
11 Benefit and Beneficiaries of the project There are a number of benefits of the project: 1. Information on the capabilities and limitations of CFD calculation tools for fire and smoke spread in under-ventilated conditions are important for different areas such a nuclear power plants, buildings, transport and energy storage. 2. The further validation of the ventilation module in FDS will be of great benefit for areas outside nuclear applications, as it would give the opportunity to run a fire simulation, which includes the ventilation system. Earlier other programmes needed to be used. It will as such also improve efficiency of fire safety calculations for ventilation systems in buildings. 3. The tests include important information on under-ventilated fires with respect to cables fires, sprinkler fires and pool fires. 4. The improvement of pool fire models is of importance for industrial applications. Beneficiaries for the project are industry (power industry, building industry, transport), consultants, governments (Boverket, SSM, MSB) and other research institutes and universities. Dissemination of the results Dissemination of the project is an important part. Due to the internal rules of OECD/NEA all results are confidential for a period of 5 years. The Swedish reports will be available through SSM, Swedish Radiation Safety Authority, at the end of the project. However in order to increase the dissemination, an extra route will be used. Publications on the project achievements can be published in international journals if the consortium agrees about this. In many cases this has not been a problem during the PRISME1 project and the Swedish project group will also use this route to speed up publication internationally. Annexes Annex 1: Summary of the Swedish part of PRISME 2 through a research article to be presented at the SMIRT conference in September 2011, submitted September 1 st. Annex 2: Results of the first benchmark exercise in PRISME1, publication of Nuclear Engineering Annex 3: Project description of the OECD/NEA PRISME 2 project Note: Other open reports from PRISME 1 are available through the applicants, Brandforsk or NBSG.
12 References [1] Information of the PRISME Project, Downloaded June [2] Rigollet L, Röwekamp M. Collaboration of fire code benchmark activities around the international fire research program PRISME. Proceedings of EUROSAFE, Brussels 2009;2(3.11). [3] Klein-Heßling W, Nowack H, Spengler C, Weber G, Höhne M, Sonnenkalb M. Cocosys--New modelling of safety relevant phenomena and components.. [4] Audouin L, Chandra L, Consalvi JL, Gay L, Gorza E, Hohm V, et al. Quantifying differences between computational results and measurements in the case of a large-scale well-confined fire scenario. Nuclear Engineering and Design [5] Rein G, Torero JL, Jahn W, Stern-Gottfried J, Ryder NL, Desanghere S, et al. Round- Robin study of a priori modelling predictions of the dalmarnock fire test one. Fire Safety Journal 2009;44(4): [6] Holmstedt G, Bengtsson S, Blomqvist P, Dittmer T, Hägglund B, Tuovinen H, Van Hees P. Kvalitetssäkring av olycks-och skadeförebyggande arbetet med brandskydd i byggnader [7] van Hees P., Johansson N., Wahlqvist J., Swedish PRISME project Part 2 - Use of test results from PRISME for practical applications in Sweden, Report 3155, ISRN: LUTVDG/TVBB SE, Lund [8] van Hees P., Wahlqvist J., Swedish PRISME project Part 4 Results of benchmark exercises at LTH, Report 3157, ISRN: LUTVDG/TVBB SE, Lund [9] van Hees P., Wahlqvist J., Hostikka S., Sikanen T., Husted B., Magnusson T., Jörud F., Prediction and validation of pool fire development in enclosures by means of CFD (Poolfire) Report Year 1, ISRN: LUTVDG/TVBB SE, Lund 2012.
13 21 st International Conference on Structural Mechanics in Reactor Technology (SMiRT 21) - 12 th International Pre-Conference Seminar on FIRE SAFETY IN NUCLEAR POWER PLANTS AND INSTALLATIONS VALIDATION AND DEVELOPMENT OF DIFFERENT CALCULATION METHODS AND SOFTWARE PACKAGES FOR FIRE SAFETY ASSESSMENT IN SWEDISH NUCLEAR POWER PLANTS Patrick van Hees 1, Nils Johansson 1, Jonathan Wahlqvist 1, Tommy Magnusson Lund University, Department of Fire Safety Engineering and Systems Safety, Sweden Ringhals AB, Sweden ABSTRACT Fire models are used increasingly for fire safety assessment in nuclear power plants. Examples of these fire models are CFD models and zone models. When using these models it is important that they are sufficiently verified and validated. In Sweden the majority of fire safety consultants are using FDS, developed by NIST. The verification and validation of this package is intensively done for a number of scenarios by the developing team. One of the recent modifications in FDS is the implementation of a ventilation module. The first aim of this paper was to validate FDS and ANSYS-CFX within the Swedish part of the OECD/NEA PRISME project using the PRISME SOURCE D1 test. The results are presented in this article and show how powerful the module is for simulation in enclosures with mechanical ventilation. Beside CFD models, fire safety engineers need also simple empirical models for determining temperatures, smoke heights, etc. In the second part of this paper such a model is developed. The model predicts gas temperatures in a room adjacent to a room involved in a pre-flashover fire. The correlation is derived with help of computer simulations and validated by means of a set of fire tests. The results of the correlation model are satisfactory and the correlation formulae will be an additional tool for fire safety engineers. INTRODUCTION Validation of CFD Models The partners participating in the international OECD/NEA project PRISME [1] investigated the use of CFD and zone models for enclosures with mechanical ventilation. This was performed in the benchmarking group. The main PRISME program (French acronym for Fire Propagation in Elementary Multi-room Scenarios ) mainly aims on studying smoke and hot gases propagation in full scale, well-confined and mechanically ventilated fire compartments [2]. In particular, the goals of the PRISME program are to understand and quantify, by means of an analytical approach, the propagation mechanisms of smoke and heat from a fire compartment towards one or several adjacent compartments in scenarios representative for nuclear plants. For this purpose one of the tests was used in an open validation exercise (a posteriori), namely the PRISME SOURCE D1 test. The exercise was performed in the PRISME consortium and reported by Audouin et al. [3] and contained validation of different zone, hybrid and CFD models. The test set-up and overview of the test rig used for the test are given in Figure 1. All the FDS results reported by Audouin et al. were based on the boundary conditions available in FDS [4] [5] at that moment, which did not have the possibility of using the most recent ventilation module developed by Floyd. This paper will report how this ventilation module in FDS have been used and applied on the PRISME SOURCE 1
14 21 st International Conference on Structural Mechanics in Reactor Technology (SMiRT 21) - 12 th International Pre-Conference Seminar on FIRE SAFETY IN NUCLEAR POWER PLANTS AND INSTALLATIONS D1 tests. Moreover, results with the commercial software ANSYS CFX [6] are also given for the same test set-up. Further details about the test can be found in the publication from the benchmark exercise [3]. Figure 1 Overview of the experimental setup (courtesy to IRSN) Use of Empirical Models Advanced computer modeling software that can predict smoke spread and compartment temperatures has been developed during the last decays. With zone models and computational fluid dynamics (CFD) it is possible to e.g. calculate smoke layer heights, species and temperatures in a multi-room geometry. The programs are generally good tools for fire engineering purposes, but they do not remove the need for simple engineering correlations. Simple correlations can be used for hand-calculations to get a first estimate of e.g. smoke layer temperatures in performance based design of a building and help the fire engineer to determine if it is necessary to perform a detailed CFD calculation. Simple correlations can also be a useful tool to use in sensitivity analysis or in fire risk analysis. Correlations that predict compartment temperatures for single room enclosures date back to the early eighties [7], [8] and are still used for different purposes by fire engineers. These correlations are rough and less accurate compared to computer simulations but they have the benefit of being simple and giving a good description of the hazard. The method that McCaffrey et al. presented [7] (MQH-correlation) is based on a simple conservation of energy expression. The MQH correlation gives the gas temperature as a function of the heat release rate, ventilation conditions, enclosure geometry and thermal properties of the enclosure. The MQH correlation has a set of limitations, which the user must be aware of, but it has been shown to give good predictions of room fire temperatures [9]. The correlation has even been developed further and modified [8], [9]. Lately new models for predicting compartment fire temperatures have 2
15 21 st International Conference on Structural Mechanics in Reactor Technology (SMiRT 21) - 12 th International Pre-Conference Seminar on FIRE SAFETY IN NUCLEAR POWER PLANTS AND INSTALLATIONS been presented [10], [11]. However there are few correlations that can predict temperatures outside the room of fire origin. Thus such predictions have to be done with the help of zone or CFD models. A simple correlation that would predict temperatures outside a compartment is something that could be useful to get a first estimate when for example evaluating conditions for evacuees in a room next to the room of fire origin or to make a first assessment with respect to functional performance of cables. Use of Empirical Models Advanced computer modeling software, that can predict smoke spread and compartment temperatures, has been developed during the last decades. With zone models and computational fluid dynamics (CFD) it is possible to e.g. calculate smoke layer heights, species concentration and temperatures in a multi-room geometry. The programs are generally good tools for fire engineering purposes, but they do not remove the need for simple engineering correlations. Simple correlations can be used for handcalculations to get a first estimate of e.g. smoke layer temperatures in performance based design of a building and help the fire engineer to determine if it is necessary to perform a detailed CFD calculation. Simple correlations can also be a useful tool to use in sensitivity analysis or in fire risk analysis. Correlations that predict compartment temperatures for single room enclosures date back to the early eighties [7], [8] and are still used for different purposes by fire engineers. These correlations are rough and less accurate compared to computer simulations but they have the benefit of being simple and giving a good description of the hazard. The method that McCaffrey et al presented [7] (MQH-correlation) is based on a simple conservation of energy expression. The MQH correlation gives the gas temperature as a function of the heat release rate, ventilation conditions, enclosure geometry and thermal properties of the enclosure. The MQH correlation has a set of limitations, which the user must be aware of, but it has been shown to give good predictions of room fire temperatures [9]. The correlation has even been developed further and modified [8], [9]. Lately new models for predicting compartment fire temperatures have been presented [10], [11]. However there are few correlations that can predict temperatures outside the room of fire origin. Thus such predictions have to be done with the help of zone or CFD models. A simple correlation that would predict temperatures outside a compartment is something that could be useful to get a first estimate when for example evaluating conditions for evacuees in a room next to the room of fire origin or to make a first assessment with respect to functional performance of cables. METHOD Validation of CFD Models The experimental scenario (Figure 1) was conducted at the French Institut de Radioprotection et de Sûreté Nucléaire (IRSN). The quantitative comparisons between measurements and numerical results obtained from open calculations concerned six important quantities from a fire safety viewpoint: gas temperature, oxygen concentration, wall temperature, total heat flux, compartment pressure and ventilation flow rate during the whole fire duration. The fire source [12] consisted of a 0.4 m 2 steel pan filled with hydrogenated tetra propylene (TPH), an isomer of n-dodecane. The walls, ceiling and floor of the room were 30 cm thick and made out of concrete. During the experiment, rock wool (THERMIPAN) with a thickness of 5 cm insulated the ceiling to prevent damage to the facility. The ventilation system in the fire room included an inlet branch and an exhaust branch, the relative static pressures and volume flow rates was record- 3
16 21 st International Conference on Structural Mechanics in Reactor Technology (SMiRT 21) - 12 th International Pre-Conference Seminar on FIRE SAFETY IN NUCLEAR POWER PLANTS AND INSTALLATIONS ed before the fire was ignited and was later used as input data in FDS simulations [13] [4] and for ANSYS-CFX [6]. Use of Empirical Models The work presented in this paper has been performed in three steps. In the first step numerous CFD simulations with the computer software FDS 5 [4] have been conducted. Input files to FDS, with randomly sized two-room configurations, were created with a Matlab script. Approximately 140 FDS files were simulations with different, geometries, openings, wall materials, fuels and heat release rates on the Lund cluster. In all simulations the fire was placed in the center of the fire room as illustrated in Figure 1. The various inputs are e.g. size of the door-opening, size of the room, HRR, fuel, properties of the wall and wall thickness. The mesh size was determined by following the recommendations of characteristic fire diameter D*, which varied between 0.61 and 1.27 m. In the second step a statistical analysis has been conducted with the statistical software package SPSS (Statistical Package for the Social Sciences) [14]. The smoke layer temperature in the adjacent room was retrieved from the FDS simulations and was used as dependent variable in the statistical analysis. The heat release rate, area of boundary surfaces of both enclosures, ventilation factors for both openings and heat transfer coefficient were used as independent variables. A multiple linear regression analysis of the logarithmic values of the variables were conducted in SPSS. In the third step the correlation was tested and validated against results from full-scale experiments both found in literature and conducted within the project. Figure 2 Room set-up for the simulations RESULTS AND DISCUSSION OF THE VALIDATION OF THE VENTILATION MODULE The leak area from the fire room to surroundings was calculated using data from PRISME SOURCE Ventilation Tests. Leakage between the fire room and surroundings was assumed to be a quadratic function of pressure difference. The calculated total leakage area from the fire room was in the order of 4 cm 2. The sensitivity of this parameter was tested by doing two more calculations with FDS, one with zero leakage, and one with 10 cm 2 leakage. As seen in Figure 3, the impact is quite large. When changing the total leakage with 4 6 cm 2, the first pressure peak in the experiment changes in the order of 50 Pa. 4
17 21 st International Conference on Structural Mechanics in Reactor Technology (SMiRT 21) - 12 th International Pre-Conference Seminar on FIRE SAFETY IN NUCLEAR POWER PLANTS AND INSTALLATIONS Figure 3 Influence of changing the room leak area in FDS The geometry used in the simulation can be seen in Figure 4. Since the full ventilation system (Figure 5) was modeled with FDS, it was necessary to compare the experimental data in every node of interest with the data produced with FDS, prior to the fire being ignited. If this proved to give a good prediction, the likelihood of getting good results when compared to the full experiment would be far larger. As can be seen in Table 1, the results agree very well with the experimental data. Only one node shows a relative pressure difference larger than 10%, though the pressure difference is only about 40 Pa. Figure 4 Geometry for the simulations with ventilation module 5
18 21 st International Conference on Structural Mechanics in Reactor Technology (SMiRT 21) - 12 th International Pre-Conference Seminar on FIRE SAFETY IN NUCLEAR POWER PLANTS AND INSTALLATIONS Figure 5 Layout of the ventilation network (courtesy to IRSN) and a comparison between FDS data and experimental data Table 1 Comparison of FDS5 results and measured pressure in each ventilation node (courtesy to IRSN) An overview of the temperatures calculated with both CFX and FDS compared to the experimental data can be seen in Figure 6. FDS manages to give a good prediction of the temperatures (within %) on a relatively coarse grid (10 cm cubes), providing a good basis for evaluating the ventilation system behavior. Unfortunately the same cannot be said about CFX. CFX over-predicts the temperature by far (30 50 %), however, it cannot be ruled out that errors made by the software operator influences this deviation. Also, the way CFX handles combustion, for example internally calculating heat of combustion, prevented use of the experimental value obtained. This will likely impact the temperatures in the fire room. Also, heat transfer to the surrounding walls has been taken into account, but it was unclear if it was properly set up even though initial tests were performed. 6
19 21 st International Conference on Structural Mechanics in Reactor Technology (SMiRT 21) - 12 th International Pre-Conference Seminar on FIRE SAFETY IN NUCLEAR POWER PLANTS AND INSTALLATIONS Figure 6 Temperature (highest and lowest measure point) as a function of time for the first 600 seconds Since full capabilities concerning ventilation system modeling is not present in CFX (simplifications were made at the in- and outlet branch, specifying appropriate boundary conditions to get realistic pressures in the fire room), only results from calculations made with FDS are presented when comparing pressure in fire room and mass flow in the ventilation branches. As seen in Figure 7, the calculated pressure in the fire room is very close to the experimental data. All pressure peaks are fairly well predicted, and this is using only data available prior to the fire being ignited (except for HRR). Figure 7 Pressure in the fire room as a function of time 7
20 21 st International Conference on Structural Mechanics in Reactor Technology (SMiRT 21) - 12 th International Pre-Conference Seminar on FIRE SAFETY IN NUCLEAR POWER PLANTS AND INSTALLATIONS Looking at the inlet and outlet branches (Figure 8) it is shown that FDS manages to predict the backflow in the inlet branch correctly. However, due to differences in the reported data from the experiment (actual measured mass flow not the same as reported in figure 3), the mass flow at the in- and outlet before the fire was ignited does not correspond to the FDS values. This in turn affects the steady-state mass flow in the later part of the experiment (after 600 seconds) making the FDS prediction somewhat incorrect. But it can be seen that the difference is constant, indicating that with the right starting values, FDS would give a better prediction. Figure 8 Mass flow in the ventilation branches as a function of time during the experiment Figure 9 Snapshot of a temperature slice during the simulations done with FDS5. The incoming cold air is clearly visible at the top left corner 8
21 21 st International Conference on Structural Mechanics in Reactor Technology (SMiRT 21) - 12 th International Pre-Conference Seminar on FIRE SAFETY IN NUCLEAR POWER PLANTS AND INSTALLATIONS Figure 10 Snapshot of a temperature slice during the simulations done with CFX In Figure 10, the incoming cold air is clearly visible at the top left corner. It can also be seen that the temperature gradient from ceiling to floor is not as steep as shown with FDS5. The maximum temperature is also overestimated to a quite large degree. RESULTS AND DISCUSSION OF THE DEVELOPMENT OF THE EMPIRICAL MODEL All included variables were statistical significant and the correlation had a correlations coefficient, R2-value, of approximately 0.9 with respect to the data from the simulations (Figure 11). The most important variable was the heat release rate. A validity check was performed by studying data from real fire tests [15], [16]. Three sets of experimental data were studied and the result of the validity check can be found in Figure 12. It is considered to be a good agreement between the calculated and measured temperatures since the maximum difference is less than 20 %. A reliability check was performed by looking at the grid sensitivity of six of the preformed simulations, when decreasing the grid size from 0.1 to 0.05 m. The presented work is based on FDS simulations of well-ventilated pre-flashover fires. Thus the results are only valid for such conditions. This could be seen when adding the PRISME data in the correlation, which turned out to be outliers. The method used to find a simple correlation for temperatures in the room adjacent to the fire room was very successfully and could possibly be applied to other areas in fire science to be able to find other simple correlations that can be used by engineers in an initial stage of their design. Some more experimental data is necessary to fully validate the developed empirical formulae and it should be investigated how the formulae could be adapted for under-ventilated conditions. This is not the case for the moment as could be seen from the data obtained via the PRISME project. 9
22 21 st International Conference on Structural Mechanics in Reactor Technology (SMiRT 21) - 12 th International Pre-Conference Seminar on FIRE SAFETY IN NUCLEAR POWER PLANTS AND INSTALLATIONS Figure 11 Correlation graph between calculated and simulated temperature increase Figure 12 Comparison between calculated and measured temperature increase (only ventilated fires) CONCLUSIONS In this paper two activities within the Swedish PRISME project were summarized. One reports on the development of a simple empirical correlation for temperatures in the room adjacent to the fire room. The development was done by numerical experiment technique and validated against a first set of test data. The results are satisfactory and further validation will be done. Application of the models is not only within fire safety design of nuclear power plants but also in traditional buildings. Another activity was the validation of the newly developed ventilation module in FDS against the PRISME Source D1 tests. The results of this validation show that the module is working properly and give satisfactory results. The intention is to validate the model against more data in PRISME project database and to implement the module in a realistic fire safety design of a traditional building where mechanical ventilation is involved. 10
23 21 st International Conference on Structural Mechanics in Reactor Technology (SMiRT 21) - 12 th International Pre-Conference Seminar on FIRE SAFETY IN NUCLEAR POWER PLANTS AND INSTALLATIONS The activities of the Swedish PRISME project, which were initiated by the nuclear industry and government in Sweden, show clear spin-off to other fire safety areas such as traditional buildings and other industrial applications. ACKNOWLEDGEMENTS The work presented in this paper has been conducted within two projects at Lund University. One is the Swedish Part of the PRISME project. The Swedish part of the PRISME project was possible thanks to financial support of Brandforsk (Swedish Board for Fire Research) and NBSG (National Fire safety Group, with representation of SSM - Swedish Radiation Safety Authority, SKB - Swedish Nuclear Fuel and Waste Management Co., Forsmark- Oskarshamn- Ringhals nuclear power plants). Parts of the validation work were also possible thanks to support of SSF (Strategic Research Fund). The other project is called Varför blir små brander stora? (Why become small fires large) and is financed by The Swedish Fire Research Board (Brandforsk) and NBSG (the Swedish NPPs Fire Safety Group). The purpose of the project is to find underlying factors to why some fires grow large. Finally the authors would like to thank IRSN in order to provide them information about the technical details of the ventilation system which was used when IRSN performed the fire tests in the PRISME project. REFERENCES [1] Information of the PRISME Project, Downloaded June 2011 [2] Rigollet, L., M. Röwekamp, Collaboration of fire code benchmark activities around the international fire research program PRISME, Proceedings of EUROSAFE, Brussels 2009, November 2011 [3] Audouin, L., et al., Quantifying differences between computational results and measurements in the case of a large-scale well-confined fire scenario, Nuclear Engineering and Design, 2010 [4] McGrattan, K. B., M. R. McDermott, S. Hostikka, J. Floyd, Fire Dynamics Simulator (Version 5) Technical Reference Guide, Volume 3: Validation, October 29, 2010 [5] McGrattan, K. B., et al., Fire dynamics simulator (Version 4), Technical Reference Guide, NIST Special Publication, National Institute for Standards and technology (NIST) Gaithersburg, MD, USA, 2004 [6] Rusch, D, L. Blum A. Moser T. Roesgen, Turbulence model validation for fire simulation by CFD and experimental investigation of a hot jet in crossflow, Fire Safety Journal 43(6), 2008, pp [7] McCaffrey, B. J., J. G. Quintiere, M. F. Harkleroad, Estimating room temperatures and the likelihood of flashover using fire test data correlations, Fire Technology 17(2), 1981, pp [8] Foote, K. L., P. J. Pagni, «Temperature correlations for forced-ventilated compartment fires, Fire Safety Science: Proceedings of the First International Symposium, 1986, p. 139 [9] Mowrer, F. W., R.B. Williamson, Estimating room temperatures from fires along walls and in corners, Fire Technology 23(2), 1987, pp [10] Delichatsios, M. A., Y. P. Lee, P. Tofilo, A new correlation for gas temperature inside a burning enclosure, Fire Safety Journal 44(8), 2009, pp
24 21 st International Conference on Structural Mechanics in Reactor Technology (SMiRT 21) - 12 th International Pre-Conference Seminar on FIRE SAFETY IN NUCLEAR POWER PLANTS AND INSTALLATIONS [11] Sharma, P., J. G. Quintiere, Compartment fire temperatures, Journal of Fire Protection Engineering 20(4), 2010, p. 253 [12] Le Saux, W., H. Prétrel, C. Lucchesi, P. Guillou, Experimental study of the fire mass loss rate in confined and mechanically ventilated multi-room scenarios, International Symposium of Fire Safety Science, 2008;9 [13] McGrattan, K. B., G. P. Forney, J. E. Floyd, S. Hostikka, K. Prasad, Fire dynamics simulator (Version 5), Users Guide, NIST Special Publication, National Institute for Standards and technology (NIST) Gaithersburg, MD, USA, 2004, p.1019 [14] [110603] [15] Rutherford, L., Experimental results for pre-flashover fire experiments in two adjacent ISO compartments, Fire Engineering Research Report, 2002 [16] Peacock, R. D., S. Davis, B. T. Lee, An experimental data set for the accuracy assessment of room fire models, Center for Fire Research,
Numerical experiments and compartment fires
Johansson Fire Science Reviews 2014, 3:2 REVIEW Open Access Numerical experiments and compartment fires Nils Johansson Abstract Fires are complex and it is hard to derive relationships from theory in fire
CFAST Consolidated Model of Fire Growth and Smoke Transport (Version 6) Software Development and Model Evaluation Guide
NIST Special Publication 86r December Revision CFAST Consolidated Model of Fire Growth and Smoke Transport (Version 6) Software Development and Model Evaluation Guide Richard D. Peacock Paul A. Reneke
EVALUATION OF PHOENICS CFD FIRE MODEL AGAINST ROOM CORNER FIRE EXPERIMENTS
EVALUATION OF PHOENICS CFD FIRE MODEL AGAINST ROOM CORNER FIRE EXPERIMENTS Yunlong Liu and Vivek Apte CSIRO Fire Science and Technology Laboratory PO Box 31 North Ryde, NSW 167, Australia TEL:+61 2 949
Piotr Tofiło a,*, Marek Konecki b, Jerzy Gałaj c, Waldemar Jaskółowski d, Norbert Tuśnio e, Marcin Cisek f
Available online at www.sciencedirect.com Procedia Engineering 57 (2013 ) 1156 1165 11th International Conference on Modern Building Materials, Structures and Techniques, MBMST 2013 Expert System for Building
Validation of Modeling Tools for Detection Design in High Airflow Environments
Validation of Modeling Tools for Detection Design in High Airflow Environments Joshua B. Dinaburg Dr. Jason Floyd, Ph.D. Dr. Sai Thumuluru, Ph.D FM Global MODELING DETECTION RESPONSE Establish validated
Modelling of fire spread in car parks
Modelling of fire spread in car parks Leander Noordijk TNO Centre for Fire Research, Delft, the Netherlands Tony Lemaire TNO Centre for Fire Research, Delft, the Netherlands Currently, design codes assume
Design fires for enclosures A first attempt to create design fires based on Euroclasses for linings
Tommy Hertzberg Björn Sundström Patrick van Hees Design fires for enclosures A first attempt to create design fires based on Euroclasses for linings BRANDFORSK project nr 314-001 SP Report 2003:02 Fire
MODELING THE PERFORMANCE OF FIRE PROTECTION SYSTEMS IN MODERN DATA CENTERS
MODELING THE PERFORMANCE OF FIRE PROTECTION SYSTEMS IN MODERN DATA CENTERS Richard W. Bukowski. P.E., FSFPE and Ralph Transue, P.E. Rolf Jensen and Associates, Chicago, IL 60661 USA Data Centers Society
ME6130 An introduction to CFD 1-1
ME6130 An introduction to CFD 1-1 What is CFD? Computational fluid dynamics (CFD) is the science of predicting fluid flow, heat and mass transfer, chemical reactions, and related phenomena by solving numerically
CARL HANSER VERLAG. Jürgen Troitzsch. Plastics Flammability Handbook Principles - Regulations - Testing and Approval 3-446-21308-2. www.hanser.
CARL HANSER VERLAG Jürgen Troitzsch Plastics Flammability Handbook Principles - Regulations - Testing and Approval 3-446-21308-2 www.hanser.de 3.1 Introduction 33 3 The Burning Process and Enclosure Fires
Improving fire safety through engineering (rational designs)
Improving fire safety through engineering (rational designs) Johan van den Heever Fire Safety Indaba, Cape Town 2013 'Promoting responsible fire safety in Southern Africa' 1 Introduction What is fire safety
NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES
Vol. XX 2012 No. 4 28 34 J. ŠIMIČEK O. HUBOVÁ NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES Jozef ŠIMIČEK email: [email protected] Research field: Statics and Dynamics Fluids mechanics
REAL SCALE TUNNEL FIRE: EXPERIMENTAL TEST INSIDE THE MORGEX TUNNEL AUTOSTRADA A5
REAL SCALE TUNNEL FIRE: EXPERIMENTAL TEST INSIDE THE MORGEX TUNNEL AUTOSTRADA A5 F. Borghetti*, P. Gandini*, R. Iuliano*, A. Frassoldati**, A. Cuoci**, M. Derudi**, S. Tavelli**. [email protected]
Improving regulatory practices through the OECD-NEA Stress Corrosion Cracking and Cable Ageing Project (SCAP)
Improving regulatory practices through the OECD-NEA Stress Corrosion Cracking and Cable Ageing Project (SCAP) A. Yamamoto a, A. Huerta a, K. Gott b, T. Koshy c a Nuclear Safety Division, OECD Nuclear Energy
Crawl space heat and moisture behaviour
Crawl space heat and moisture behaviour Miimu Airaksinen, Dr., Technical Research Centre of Finland, VTT [email protected], www.vtt.fi KEYWORDS: crawl space, moisture, evaporation from ground, ground
Analysis of the UNH Data Center Using CFD Modeling
Applied Math Modeling White Paper Analysis of the UNH Data Center Using CFD Modeling By Jamie Bemis, Dana Etherington, and Mike Osienski, Department of Mechanical Engineering, University of New Hampshire,
Investigations of a Long-Distance 1000 MW Heat Transport System with APROS Simulation Software
th International Conference on Structural Mechanics in Reactor Technology (SMiRT ) Espoo, Finland, August 9-4, 9 SMiRT -Division 3, Paper 56 Investigations of a Long-Distance MW Heat Transport System with
CFD STUDY OF TEMPERATURE AND SMOKE DISTRIBUTION IN A RAILWAY TUNNEL WITH NATURAL VENTILATION SYSTEM
CFD STUDY OF TEMPERATURE AND SMOKE DISTRIBUTION IN A RAILWAY TUNNEL WITH NATURAL VENTILATION SYSTEM J. Schabacker, M. Bettelini, Ch. Rudin HBI Haerter AG Thunstrasse 9, P.O. Box, 3000 Bern, Switzerland
INITIAL ASSESSMENT OF THE IMPACT OF JET FLAME HAZARD FROM HYDROGEN CARS IN ROAD TUNNELS AND THE IMPLICATION ON HYDROGEN CAR DESIGN
INITIAL ASSESSMENT OF THE IMPACT OF JET FLAME HAZARD FROM HYDROGEN CARS IN ROAD TUNNELS AND THE IMPLICATION ON HYDROGEN CAR DESIGN Wu, Y Department of Chemical and Process Engineering, University of Sheffield,
GT2011 46090 ANALYSIS OF A MICROGASTURBINE FED BY NATURAL GAS AND SYNTHESIS GAS: MGT TEST BENCH AND COMBUSTOR CFD ANALYSIS
ASME Turbo Expo 2011 June 6 10, 2011 Vancouver, Canada GT 2011 46090 ANALYSIS OF A MICROGASTURBINE FED BY NATURAL GAS AND SYNTHESIS GAS: MGT TEST BENCH AND COMBUSTOR CFD ANALYSIS M. Cadorin 1,M. Pinelli
Challenges for Use of Fixed Fire Suppression Systems in Road Tunnel Fire Protection
Challenges for Use of Fixed Fire Suppression Systems in Road Tunnel Fire Protection Z. G. Liu *, A. Kashef, G. Lougheed, and A. K. Kim Fire Research Program, Institute for Research in Construction National
Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1
Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1 Nuclear Power in Pakistan Nuclear Power Plants Capacity (MWe) Year of Commissioning In
FIRE RISK ASSESSMENT IN GERMANY - PROCEDURE, DATA, RESULTS -
International Conference Nuclear Energy in Central Europe 2000 Golf Hotel, Bled, Slovenia, September 11-14, 2000 FIRE RISK ASSESSMENT IN GERMANY - PROCEDURE, DATA, RESULTS - H.P. Berg Bundesamt für Strahlenschutz
SMOKE HAZARD ASSESSMENT USING COMPUTATIONAL FLUID DYNAMICS (CFD) MODELLING
SMOKE HAZARD ASSESSMENT USING COMPUTATIONAL FLUID DYNAMICS (CFD) MODELLING Baldev S Kandola and Mark Morris AEA Consultancy Services (SRD), Thomson House, Risley, Warrington, Cheshire WA3 6AT Fire is a
Approval Standard for Plastic Suspended Ceiling Panels
Approval Standard for Plastic Suspended Ceiling Panels Class Number 4651 February 1978 2002 FM Approvals LLC. All rights reserved. Foreword The FM Approvals certification mark is intended to verify that
Express Introductory Training in ANSYS Fluent Lecture 1 Introduction to the CFD Methodology
Express Introductory Training in ANSYS Fluent Lecture 1 Introduction to the CFD Methodology Dimitrios Sofialidis Technical Manager, SimTec Ltd. Mechanical Engineer, PhD PRACE Autumn School 2013 - Industry
2013 Code_Saturne User Group Meeting. EDF R&D Chatou, France. 9 th April 2013
2013 Code_Saturne User Group Meeting EDF R&D Chatou, France 9 th April 2013 Thermal Comfort in Train Passenger Cars Contact For further information please contact: Brian ANGEL Director RENUDA France [email protected]
NUCLEAR ENERGY RESEARCH INITIATIVE
NUCLEAR ENERGY RESEARCH INITIATIVE Experimental and CFD Analysis of Advanced Convective Cooling Systems PI: Victor M. Ugaz and Yassin A. Hassan, Texas Engineering Experiment Station Collaborators: None
Using Risk Assessment Tool to Evaluate the Fire-Induced Core Damage Frequency
, June 30 - July 2, 2010, London, U.K. Using Risk Assessment Tool to Evaluate the Fire-Induced Core Damage Frequency Sh. Kamyab, M. Nematollahi, M. Famourihoseinzade Abstract the frequency of fire-induced
CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER
International Journal of Advancements in Research & Technology, Volume 1, Issue2, July-2012 1 CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER ABSTRACT (1) Mr. Mainak Bhaumik M.E. (Thermal Engg.)
NUMERICAL SIMULATION OF FLOW FIELDS IN CASE OF FIRE AND FORCED VENTILATION IN A CLOSED CAR PARK
FACULTY OF ENGINEERING NUMERICAL SIMULATION OF FLOW FIELDS IN CASE OF FIRE AND FORCED VENTILATION IN A CLOSED CAR PARK Xavier Deckers, Mehdi Jangi, Siri Haga and Bart Merci Department of Flow, Heat and
Fire Development and Fire Behavior Indicators
Battalion Chief Ed Hartin, MS, EFO, MIFireE, CFO Introduction Building Factors, Smoke, Air Track, Heat, and Flame (B-SAHF) are critical fire behavior indicators. Understanding the indicators is important,
Exova Warringtonfire fire safety engineering
Consultancy - Fire Engineering Exova Warringtonfire fire safety engineering We are committed to the philosophy where the fire safety design supports the vision, innovation or imagination of the building
Development of Ventilation Strategy in Diesel Engine Power Plant by Using CFD Modelling
Development of Ventilation Strategy in Diesel Engine Power Plant by Using CFD Modelling Panu Mustakallio and Risto Kosonen Halton Oy, Haltonintie 1-3, 47400 Kausala, Finland E-mail: [email protected]
Integrated CFD Models for Air-sampling Smoke Detection
Integrated CFD Models for Air-sampling Smoke Detection Yun Jiang 1, John Vythoulkas & Scott Wilson 2 Xtralis AG. ABSTRACT Computational Fluid Dynamic ( CFD ) modelling is becoming a powerful tool both
Lecture 6 - Boundary Conditions. Applied Computational Fluid Dynamics
Lecture 6 - Boundary Conditions Applied Computational Fluid Dynamics Instructor: André Bakker http://www.bakker.org André Bakker (2002-2006) Fluent Inc. (2002) 1 Outline Overview. Inlet and outlet boundaries.
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU George CURCANU, Constantin ILINCA, Ilie SBORA ICMET Craiova, Romania, Calea Bucuresti 144, phone:
Fire Performance Standard
Fire Performance Standard At present, in cable industry, Fire Retardant, Low Smoke Halogen Free (LSZH), Low Smoke Fume (LSF) and Fire Resistant cables are all described as Fire survival Cables. Flame Retardant
CFD Grows Up! Martin W. Liddament Ventilation, Energy and Environmental Technology (VEETECH Ltd) What is Computational Fluid Dynamics?
CIBSE/ASHRAE Meeting CFD Grows Up! Martin W. Liddament Ventilation, Energy and Environmental Technology (VEETECH Ltd) 10 th December 2003 What is Computational Fluid Dynamics? CFD is a numerical means
Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial
Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial facilities commonly occupy spaces with ceilings ranging between twenty and thirty feet in height.
Introduction. Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS)
1 Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS) Introduction The new harmonised system for the classification of reaction to fire in EU member states is using the SBI test
An Overview of the International Road Tunnel Fire Detection Research Project
An Overview of the International Road Tunnel Fire Detection Research Project Introduction Z. Liu 1, A. Kashef, G. Lougheed, J. Z. Su and N. Benichou Fire Research Program, Institute for Research in Construction
Abaqus/CFD Sample Problems. Abaqus 6.10
Abaqus/CFD Sample Problems Abaqus 6.10 Contents 1. Oscillatory Laminar Plane Poiseuille Flow 2. Flow in Shear Driven Cavities 3. Buoyancy Driven Flow in Cavities 4. Turbulent Flow in a Rectangular Channel
Fire Security Systems
Fire Security Systems Fire Security Systems [email protected] www.fire-security.net P: 1 604 941 1001 F: 1 604 648 9311 Who is Fire Security Systems For 25 years, Fire Security has been involved in
Customer Training Material. Lecture 2. Introduction to. Methodology ANSYS FLUENT. ANSYS, Inc. Proprietary 2010 ANSYS, Inc. All rights reserved.
Lecture 2 Introduction to CFD Methodology Introduction to ANSYS FLUENT L2-1 What is CFD? Computational Fluid Dynamics (CFD) is the science of predicting fluid flow, heat and mass transfer, chemical reactions,
Pushing the limits. Turbine simulation for next-generation turbochargers
Pushing the limits Turbine simulation for next-generation turbochargers KWOK-KAI SO, BENT PHILLIPSEN, MAGNUS FISCHER Computational fluid dynamics (CFD) has matured and is now an indispensable tool for
Numerical Calculation of Laminar Flame Propagation with Parallelism Assignment ZERO, CS 267, UC Berkeley, Spring 2015
Numerical Calculation of Laminar Flame Propagation with Parallelism Assignment ZERO, CS 267, UC Berkeley, Spring 2015 Xian Shi 1 bio I am a second-year Ph.D. student from Combustion Analysis/Modeling Lab,
Use of OpenFoam in a CFD analysis of a finger type slug catcher. Dynaflow Conference 2011 January 13 2011, Rotterdam, the Netherlands
Use of OpenFoam in a CFD analysis of a finger type slug catcher Dynaflow Conference 2011 January 13 2011, Rotterdam, the Netherlands Agenda Project background Analytical analysis of two-phase flow regimes
Andrea Basti* Italian National Institute of Nuclear Physics (INFN) Gran Sasso National Laboratory (LNGS) *Research Grant Holder
Evaluation of the possibility to use waterscreen for people evacuation from the Gran Sasso National Laboratory inside the Gran Sasso highway tunnel in case of fire The case of The Gran Sasso National Laboratory
Part IV. Conclusions
Part IV Conclusions 189 Chapter 9 Conclusions and Future Work CFD studies of premixed laminar and turbulent combustion dynamics have been conducted. These studies were aimed at explaining physical phenomena
International Refrigerant Standards and their Influence on the Global HVAC Industry and Refrigerant Replacement
International Refrigerant Standards and their Influence on the Global HVAC Industry and Refrigerant Replacement Tom Watson, P.E. Fellow ASHRAE, Life Member President ASHRAE Issues Choosing a refrigerant
Introduction to CFD Analysis
Introduction to CFD Analysis 2-1 What is CFD? Computational Fluid Dynamics (CFD) is the science of predicting fluid flow, heat and mass transfer, chemical reactions, and related phenomena by solving numerically
Industrial Application of CFD in Airbus
STAR Konferenz Deutschland 9.-10. November 2009 November 2009 Dr.-Ing. Andreas Wick Environmental Control Systems CFD Focal Point Airbus Operations GmbH Industrial Application of CFD in Airbus An Air Systems
Development of Seismic-induced Fire Risk Assessment Method for a Building
Development of Seismic-induced Fire Risk Assessment Method for a Building AI SEKIZAWA National Research Institute of Fire and Disaster 3-14-1, Nakahara, Mitaka, Tokyo 181-8633, Japan [email protected]
Impacts of Perforated Tile Open Areas on Airflow Uniformity and Air Management Performance in a Modular Data Center
Impacts of Perforated Tile Open Areas on Airflow Uniformity and Air Management Performance in a Modular Data Center Sang-Woo Ham 1, Hye-Won Dong 1, Jae-Weon Jeong 1,* 1 Division of Architectural Engineering,
How To Model With Cfd Using Phoenics
The Use and Application of CFD in the Air Conditioning and Fire Protection Industry AIRAH NSW February 2008 The Use and Application of CFD in the Air Conditioning and Fire Protection Industry An Introduction
The risk assessment of fire damper installations
The risk assessment of fire damper installations June 2010 Paul White OVERVIEW OVERVIEW The purpose of this presentation is to highlight that fire dampers form a key part of the passive fire protection
People Evacuation: Simplified Evaluation of Available Safe Egress Time (ASET) in Enclosures
A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 26, 2012 Guest Editors: Valerio Cozzani, Eddy De Rademaeker Copyright 2012, AIDIC Servizi S.r.l., ISBN 978-88-95608-17-4; ISSN 1974-9791 The Italian
Energy Efficient Data Center Design. Can Ozcan Ozen Engineering Emre Türköz Ozen Engineering
Energy Efficient Data Center Design Can Ozcan Ozen Engineering Emre Türköz Ozen Engineering 1 Bio Can Ozcan received his Master of Science in Mechanical Engineering from Bogazici University of Turkey in
Numerical Investigation of Heat Transfer Characteristics in A Square Duct with Internal RIBS
merical Investigation of Heat Transfer Characteristics in A Square Duct with Internal RIBS Abhilash Kumar 1, R. SaravanaSathiyaPrabhahar 2 Mepco Schlenk Engineering College, Sivakasi, Tamilnadu India 1,
INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)
INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) Proceedings of the 2 nd International Conference on Current Trends in Engineering and Management ICCTEM -2014 ISSN 0976 6340 (Print)
Jan-Anders Larsson Scanscot Technology AB. Design Guide for Nuclear Civil Structures Dimensionering av nukleära byggnadskonstruktioner (DNB)
Jan-Anders Larsson Scanscot Technology AB Design Guide for Nuclear Civil Structures Dimensionering av nukleära byggnadskonstruktioner () GUIDE FOR NUCLEAR CIVIL STRUCTURES - NEW GUIDE Design Guidance for
Fire Hazard Calculations for Hydrocarbon Pool Fires Application of Fire Dynamics Simulator FDS to the Risk Assessment of an Oil Extraction Platform
Fire Hazard Calculations for Hydrocarbon Pool Fires Application of Fire Dynamics Simulator FDS to the Risk Assessment of an Oil Extraction Platform Stefania Benucci, Giovanni Uguccioni D Appolonia S.p.A
Natural convection in a room with two opposite heated vertical walls
INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENT Volume 6, Issue 1, 2015 pp.81-86 Journal homepage: www.ijee.ieefoundation.org Natural convection in a room with two opposite heated vertical walls Ameer
Introduction to CFD Analysis
Introduction to CFD Analysis Introductory FLUENT Training 2006 ANSYS, Inc. All rights reserved. 2006 ANSYS, Inc. All rights reserved. 2-2 What is CFD? Computational fluid dynamics (CFD) is the science
TATA Scunthorpe Queen Anne- taphole suction hood optimisation by CFD simulation and physical modelling
1 TATA Scunthorpe Queen Anne- taphole suction hood optimisation by CFD simulation and physical modelling Author(s) Name(s) and Affiliations(s) Bob PETERS, Paul Wurth S.A. Luxembourg, Jean-Paul SIMOES,
CONE CALORIMETER A TOOL FOR MEASURING HEAT RELEASE RATE
CONE CALORIMETER A TOOL FOR MEASURING HEAT RELEASE RATE Johan Lindholm, Anders Brink and Mikko Hupa Åbo Akademi Process Chemistry Centre, Biskopsgatan 8, FI-20500 Åbo, FINLAND Corresponding author: E-mail:
Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number 610.14351-R1D1. 13 January 2015
EcoPelmet Pty Ltd c/- Geoff Hesford Engineering 45 Market Street FREMANTLE WA 6160 Version: Page 2 PREPARED BY: ABN 29 001 584 612 2 Lincoln Street Lane Cove NSW 2066 Australia (PO Box 176 Lane Cove NSW
Effectiveness assessment of road tunnel fire-fighting strategies by ventilation and water mist systems
by ventilation and water mist systems Effectiveness assessment of road tunnel fire-fighting by ventilation and water mist systems 1 by ventilation and water mist systems In order to assess the effectiveness
Fire Simulations in Civil Engineering
Contact: Lukas Arnold l.arnold@fz- juelich.de Nb: I had to remove slides containing input from our industrial partners. Sorry. Fire Simulations in Civil Engineering 07.05.2013 Lukas Arnold Fire Simulations
Qualification of Thermal hydraulic codes within NURESIM D. Bestion (CEA, France)
Qualification of Thermal hydraulic codes within NURESIM D. Bestion (CEA, France) The thermalhydraulic codes used for nuclear safety applications Validation and Verification of codes Validation of system
Electrical Classification
Electrical Classification Using NFPA 70 and NFPA 499 to Classify Hazardous Locations Electrical classifications are established in accordance with the National Electrical Code, NFPA 70, also referred to
Dynamic Process Modeling. Process Dynamics and Control
Dynamic Process Modeling Process Dynamics and Control 1 Description of process dynamics Classes of models What do we need for control? Modeling for control Mechanical Systems Modeling Electrical circuits
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES Interpretations of the FTP CONTENTS FTP1 Adhesives used in A or B class divisions (FTP Code 3.1, Res A.754 para. 3.2.3) June 2000 FTP2 Pipe and duct
Fire Resistance and Safety in Case of Fire
Fire Resistance and Safety in Case of Fire Franck GYPPAZ Nexans Research Center [email protected] April 2014 Page 1/12 Table of content 1 Introduction... 3 2 Fire development... 3 2.1 Ignition...
APPLICATION OF DATA MINING TECHNIQUES FOR BUILDING SIMULATION PERFORMANCE PREDICTION ANALYSIS. email [email protected]
Eighth International IBPSA Conference Eindhoven, Netherlands August -4, 2003 APPLICATION OF DATA MINING TECHNIQUES FOR BUILDING SIMULATION PERFORMANCE PREDICTION Christoph Morbitzer, Paul Strachan 2 and
NUMERICAL INVESTIGATIONS ON HEAT TRANSFER IN FALLING FILMS AROUND TURBULENCE WIRES
NUMERICAL INVESTIGATIONS ON HEAT TRANSFER IN FALLING FILMS AROUND TURBULENCE WIRES Abstract H. Raach and S. Somasundaram Thermal Process Engineering, University of Paderborn, Paderborn, Germany Turbulence
Report. Test of stove guard SFC300RF in combination with stove alarm SA102RF. Authors Sindre Fjær. SINTEF NBL as Reaction to fire 2012-03-26
- Restricted Report Test of stove guard SFC300RF in combination with stove alarm SA102RF Test based on requirement specification from the Swedish Institute of Assistive Technology (SIAT) Authors Sindre
Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009
Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009 By Carsten Palle, VID Fire-Fill, www.vid.eu Presented at ISTSS
(1) 2 TEST SETUP. Table 1 Summary of models used for calculating roughness parameters Model Published z 0 / H d/h
Estimation of Surface Roughness using CFD Simulation Daniel Abdi a, Girma T. Bitsuamlak b a Research Assistant, Department of Civil and Environmental Engineering, FIU, Miami, FL, USA, [email protected]
Safety Storage Cabinets
Safety Storage Cabinets Safe storage of flammables? The workplace without a fire resistant Safety Storage Cabinet Dangers, risks and your disadvantages... STORAGE ROOM Transport/working time - Increased
Flow in data racks. 1 Aim/Motivation. 3 Data rack modification. 2 Current state. EPJ Web of Conferences 67, 02070 (2014)
EPJ Web of Conferences 67, 02070 (2014) DOI: 10.1051/ epjconf/20146702070 C Owned by the authors, published by EDP Sciences, 2014 Flow in data racks Lukáš Manoch 1,a, Jan Matěcha 1,b, Jan Novotný 1,c,JiříNožička
CFD simulation of fibre material transport in a PWR core under loss of coolant conditions
CFD simulation of fibre material transport in a PWR core under loss of coolant conditions T. Höhne, A. Grahn, S. Kliem Forschungszentrum Dresden- Rossendorf (FZD) Institut für Sicherheitsforschung Postfach
English Version. Fire safety storage cabinets - Part 2: Safety cabinets for pressurised gas cylinders
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM EN 14470-2 August 2006 ICS 13.220.40; 71.040.10 English Version Fire safety storage cabinets - Part 2: Safety cabinets for pressurised gas cylinders
Adaptation and validation of OpenFOAM CFD-solvers for nuclear safety related flow simulations
Adaptation and validation of OpenFOAM CFD-solvers for nuclear safety related flow simulations SAFIR2010 Seminar, 10.-11.3.2011, Espoo Juho Peltola, Timo Pättikangas (VTT) Tomas Brockmann, Timo Siikonen
Calculation of Liquefied Natural Gas (LNG) Burning Rates
Calculation of Liquefied Natural Gas (LNG) Burning Rates Carolina Herrera, R. Mentzer, M. Sam Mannan, and S. Waldram Mary Kay O Connor Process Safety Center Artie McFerrin Department of Chemical Engineering
NUMERICAL INVESTIGATION OF HEAT AND MASS TRANSFER IN A REFRIGERATED TRUCK COMPARTMENT
NUMERICAL INVESTIGATION OF HEAT AND MASS TRANSFER IN A REFRIGERATED TRUCK COMPARTMENT T. LAFAYE DE MICHEAUX (a), V. SARTRE (a)*, A. STUMPF (b), J. BONJOUR (a) (a) Université de Lyon, CNRS INSA-Lyon, CETHIL,
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to
WHITE PAPER Fire & safety performance standards
WHITE PAPER Fire & safety performance standards Terminologies describing Fire Performance Terminologies describing Fire Performance often present a challenge to understand as how they apply to a cable
University Turbine Systems Research 2012 Fellowship Program Final Report. Prepared for: General Electric Company
University Turbine Systems Research 2012 Fellowship Program Final Report Prepared for: General Electric Company Gas Turbine Aerodynamics Marion Building 300 Garlington Rd Greenville, SC 29615, USA Prepared
APC APPLICATION NOTE #92
#92 Best Practices for Designing Data Centers with the InfraStruXure InRow RC By John Niemann Abstract The InfraStruXure InRow RC is designed to provide cooling at the row and rack level of a data center
Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling
IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 8, Issue 6 (Sep. - Oct. 2013), PP 25-29 Performance of the Boiler and To Improving the Boiler Efficiency
Operating Performance: Accident Management: Severe Accident Management Programs for Nuclear Reactors REGDOC-2.3.2
Operating Performance: Accident Management: Severe Accident Management Programs for Nuclear Reactors REGDOC-2.3.2 September 2013 Accident Management: Severe Accident Regulatory Document REGDOC-2.3.2 Canadian
CFD Analysis of a Centrifugal Pump with Supercritical Carbon Dioxide as a Working Fluid
KNS 2013 Spring CFD Analysis of a Centrifugal Pump with Supercritical Carbon Dioxide as a Working Fluid Seong Gu Kim Jeong Ik Lee Yoonhan Ahn Jekyoung Lee Jae Eun Cha Yacine Addad Dept. Nuclear & Quantum
Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger
International Journal of Engineering Research and Technology. ISSN 0974-3154 Volume 6, Number 1 (2013), pp. 33-40 International Research Publication House http://www.irphouse.com Comparison of Heat Transfer
Influence of fire source locations on the actuation of wet-type sprinklers in an office fire
Influence of fire source locations on the actuation of wet-type sprinklers in an office fire Ko-Jen Chen 1 Chun-Ta Tzeng 2 Chi-ming Lai 3 Abstract An experiment is conducted on a full-scale model office
Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001
Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001 Presented by: Liberty Engineering, LLP 1609 Connecticut Avenue
