Lasers and Specturbility of Light Scattering Liquids - A Review
|
|
|
- Delphia Fletcher
- 5 years ago
- Views:
Transcription
1 Artigo Original Revista Brasileira de Física Médica.2011;5(1): Reproducibility of radiant energy measurements inside light scattering liquids Reprodutibilidade de medidas de energia radiante dentro de líquidos espalhadores de luz Ana C. de Magalhães and Elisabeth M. Yoshimura Institute of Physics of São Paulo University/Nuclear Physics Department, São Paulo (SP), Brazil. Abstract The aim of this project is to evaluate the uncertainty associated with measurements performed with laser beams in scattering liquids with optical fibers. Two lasers with different wavelengths were used, nm and 820 nm, to illuminate a cuvette with Lipovenos PLR, the scattering liquid. A mask at the top of the cuvette was used to control the positioning of 250 µm optical fiber and the laser entrance point. The light energy was measured with an optical power meter, and the integration time was 60 s, measured with a chronometer. There were no systematic errors associated with the integration time. Two tests were done to evaluate the uncertainty associated with the positioning of the components of the experimental arrangement. To evaluate the uncertainty of the positioning of the cuvette, seven series of measurements with the optical fiber 5 mm far from the beam were performed. Between two series, the cuvette was removed from the holder, the liquid was mixed and the cuvette was put back in the same position. A second test was done to evaluate the reproducibility of fiber positioning and the relative positioning of mask and cuvette. Three distances between the beam and the fiber were used: 4 mm, 5 mm and 6 mm, through the positioning of the fiber at three different holes in the mask. Six series of measurements were performed. Between two series, the cuvette was removed from the holder, the liquid was mixed and the cuvette was put back in the same position. Each series was done in a different order, permuting the three positions. The uncertainty associated with the positioning of the experimental elements was of the order of 7%. The variation of incident laser energy was also evaluated, resulting in 6.5% and 4.0% for the red and infrared lasers respectively. Keywords: laser, scattering liquids, light energy. Resumo O objetivo deste projeto é avaliar a incerteza associada às medidas realizadas com feixes de laser em líquidos espalhadores com fibras ópticas. Dois lasers com diferentes comprimentos de onda foram utilizados, 632,8 e 820 nm, para iluminar uma cubeta com Lipovenos PLR, o líquido espalhador. Uma máscara no topo da cubeta foi utilizada para controlar o posicionamento da fibra óptica de 250 µm e o ponto de entrada do laser. A energia da luz foi medida com um medidor de potência óptica (Optical Meter), o tempo de integração foi de 60 segundos, medido com um cronômetro. Não houve erros sistemáticos associados com o tempo de integração. Dois testes foram realizados para avaliar a incerteza associada com o posicionamento dos componentes do arranjo experimental. Para avaliar a incerteza do posicionamento da cubeta, foram realizadas sete séries de medidas com fibra óptica a 5 mm de distância do feixe. Entre duas séries, a cubeta foi removida do recipiente, o líquido foi misturado e a cubeta foi colocada na mesma posição novamente. Um segundo teste foi realizado para avaliar a reprodutibilidade do posicionamento da fibra e o relativo posicionamento da máscara e da cubeta. Três distâncias entre o feixe e a fibra foram utilizadas: 4, 5 e 6 mm, por meio do posicionamento da fibra em três diferentes orifícios na máscara. Seis séries de medidas foram realizadas. Entre duas séries, a cubeta foi removida do recipiente, o líquido foi misturado e a cubeta foi posta novamente na mesma posição. Cada série foi realizada em uma ordem diferente, mudando as três posições. A incerteza associada com o posicionamento dos elementos experimentais foi da ordem de 7%. A variação da energia de laser incidente também foi avaliada, resultando em 6,5 e 4,0% para os lasers vermelho e infravermelho, respectivamente. Palavras-chave: laser, líquidos espalhadores, energia da luz. Introduction The determination of the uncertainty associated with an experimental arrangement is very important. It determines the reliability of the experiment. In our experiment, with the uncertainty, is possible to distinguish measurements and to investigate variations of light energy inside an illuminated volume. The aim of this project was to evaluate the reproducibility of light energy measurements on scattering liquids with the use of an optical fiber coupled in an optical meter, in order to determine the uncertainty associated to the positioning of the experimental components and analyze the main uncertainty components. Corresponding author: Ana Carolina de Magalhães Instituto de Física Rua do Matão, Travessa R, 187 Cidade Universitária São Paulo (SP), Brazil CEP: [email protected] Associação Brasileira de Física Médica 57
2 Magalhães AC, Yoshimura EM Materials and methods A cylindrical cuvette was used, with 25 mm diameter, with a plane window with 10 mm of width, parallel to the cylinder axis, as it is possible to see at Figure 1-A and 1-B. Lipovenos PLR, which is a lipid emulsion for intravenous use and has scattering behavior 1, was used as scattering liquid. An optical fi ber with a diameter of 250 μm was used to collect the scattered light. The fi ber was guided by a metallic tube (internal diameter of 0.85 mm, external diameter of 1.5 mm and mm length) in order to make sure that the fi ber was vertical and that its entering position in the liquid could be measured. The fi ber depth in the liquid was 5 mm and this portion of fi ber was without protective cover. A mask, detailed in Figure 1-C, was used in order to allow the controlled positioning of the optical fi ber in relation to the laser beam. The central hole, for the laser beam, has a diameter of 3 mm, and each one of the other holes, for the optical fi ber, has a diameter of 1.5 mm. The fi rst hole is at a distance of 4 mm of the center, the second is at 5 mm and so on, until the last one that is at 11 mm of the center. The fi nal experimental arrangement is represented at Figure 2. Lasers with two different wavelengths were used, one in red range (He-Ne, nm) and the other in infrared range, 820 nm. The circular beams reached the center of the cuvette, passing through the mask central hole. In the case of infrared laser, an aperture was used to ensure that the laser beam reaching the liquid was circular. An optical meter (Newport Hand-Held Optical meter, model 1918-C) with a connector to optical fi bers was used in integration mode, and the signal was integrated in 60 s. This measurement was taken with a chronometer, as the optical meter doesn t have this function. In order to determine the uncertainty associated with the positioning of the cuvette and the optical fi ber, two reproducibility tests were carried out. The objective of the fi rst one (R1) was to evaluate the reproducibility of the positioning of the cuvette in the holder for illumination. Seven series of seven measurements with the optical fi - ber 5 mm far from the beam were performed. Between two series, the cuvette was removed from the holder, the liquid was mixed and the cuvette was put back in the same position. The objective of the second test (R2) was to evaluate the reproducibility of the optical fi ber positioning and the relative positioning of mask and cuvette. Three distances between the beam and the fi ber were used: 4 mm, 5 mm and 6 mm, through the positioning of the fi ber at three different holes in the mask. Six series of seven measurements with the fi ber at each of the three positions were performed. Between two series, the cuvette was removed from the holder, the liquid was mixed and the cuvette was put back in the same position. Each series was composed by a different permutation of the three positions. Data of the incident energy from the lasers were collected in order to determine the stability of this value. These measurements were done with the same optical meter, but without the optical fi ber attachment, in order to determine how the lasers, the mask and the aperture affect the results obtained. For red laser, measurements were taken at two different positions: position 1 - before the mask; and position 2 - behind the mask. For infrared laser, measurements at three different positions were taken: position 0 - before the aperture; position 1 - between the aperture and the mask; and position 2 - behind the mask. The positions 1 and 2 are the same for both lasers. 50 mm B C A Figure 1. Figure of the cuvette used at the experiment. A) Threedimensional view; and B) cross-section view. At C, is shown the mask used at the experiment to position the optical fi ber and the laser beam. Figure 2. Figure of the experimental arrangement used. The laser is represented by the red line. The optical fi ber is represented by the green line, the fi ber depth in the liquid is 5 mm. The mask used is represented in A, it has a central hole for the laser beam and eight radial holes for the fi ber. 58 Revista Brasileira de Física Médica.2011;5(1):57-62.
3 Reproducibility of radiant energy measurements inside light scattering liquids Results He-Ne laser The results obtained for the wavelength nm for the test R1 are represented at the graphs of Figures 3 and 4. The data sequence for test R2 is shown at the graph of Figure 5, in which it is possible to see a change at the data for all distances, because of the same reasons of test R1. At Table 1 are the values for average, standard deviation and coeffi cient of variation for each test. The results for the measurements of laser incident energy are shown at Figure 6. The energy is relative to the average of the measurements of each position (position 1 and 2). There are no irregularities at the data, showing that the laser output is stable. Results for average, standard deviation, coeffi cient of variation and sample size are shown at Table 1. Figure 5. Graph with data for test R2, red laser. The graph shows data in chronological order for each distance from the fi ber to the center of the cuvette Energy (nj) ,85 59,90 59,95 60,00 60,05 60,10 60,15 60,20 Integration time (s) Figure 3. Graph with data for test R1, red laser. The graph shows integration time dispersion data, measured with manual chronometer. Energy (nj) Data number Figure 4. Graph with data for test R1, red laser. The graph shows data in chronological order. The arrows correspond to the change of measure series. Figure 6. Graph with data for laser incident energy, red laser. The energy is relative to the average of the measurements of each position. Table 1. Average, standard deviation and coeffi cient of variation of the radiant energy for each test (R1 and R2) realized with red laser and data for laser incident energy at positions 1 and 2 (lines Pos 1 and Pos 2, respectively). Test/ distance Average (nj) Standard deviation (nj) Coeffi cient of variation (%) Sample size R R2/4 mm R2/5 mm R2/6 mm Pos Pos Revista Brasileira de Física Médica.2011;5(1):
4 Magalhães AC, Yoshimura EM Infrared laser The data obtained for test R1, in chronological order, are shown at the graph of Figure 7. It is possible to note, at graph of Figure 7, that data oscillate a lot, without any clear change, neither tendencies. For test R2, the results are shown at the graph of Figure 8, in which is possible to note that there is a big change at energy for all distances after the seventh measurement. The reason for this alteration is a variation of the incident laser energy, which is changed by a factor of 2.6. After this big change, other variations with this magnitude did not occur. Table 2. Average, standard deviation and coeffi cient of variation of the radiant energy for each test (R1 and R2) realized with infrared laser and data for laser incident energy at positions 0, 1 and 2 (lines Pos 0, Pos 1 and Pos 2, respectively). Test/ distance Average (nj) Standard deviation (nj) Coeffi cient of variation (%) Sample Size R R2/4 mm R2/5 mm R2/6 mm Pos Pos Pos The results for the measurements of laser incident energy are shown at Figure 9. The energy is relative to the average of the measurements of each position (position 0, 1 and 2). There are no irregularities at the data, what means that there are not big variations of incident energy and there is not any important effect of the aperture and the mask. Results for average, standard deviation, coeffi cient of variation and sample size are shown at Table 2. Figure 7. Graph with data for test R1, infrared laser. The graph shows data in chronological order. Figure 9. Graph with data for laser incident energy, infrared laser. The energy is relative to the average of the measurements of each position. Figure 8. Graph with data for test R2, infrared laser. The graph shows data in chronological order for each distance measured. At Table 2 are the values for average, standard deviation and coeffi cient of variation for each test. Probably, the low standard deviation obtained for test R2, at distance of 4 mm, occurred because three series of measurements at this position were lost. Conclusions Through the analysis of the data, it was concluded that there are no tendencies related to the integration time, what is seen at integration time dispersion graphs. Therefore, it is possible to say that this source of error is considered when the energy analysis is done. There is an uncertainty associated to the optical fi - ber and cuvette positioning, shown by the standard 60 Revista Brasileira de Física Médica.2011;5(1):57-62.
5 Reproducibility of radiant energy measurements inside light scattering liquids deviation obtained for each group. As they have similar magnitudes, varying roughly between 2 and 8%, we will adopt 7% as a value of the uncertainty associated with the data collection. It is equivalent to the largest standard deviation found for the series data. A large portion of the radiant energy data variation is due to the laser stability, as the coefficients of variation of the incident energy are similar to the standard deviation of the reproducibility experiments. Acknowledgment The authors thank the personnel of the Optical Laboratory of Institute of Physics, where the measurements were done. References 1. Pogue BW, Patterson MS. Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry. J Biomed Opt. 2006;11(4): Revista Brasileira de Física Médica.2011;5(1):
6
Evaluation of the image quality in computed tomography: different phantoms
Artigo Original Revista Brasileira de Física Médica.2011;5(1):67-72. Evaluation of the image quality in computed tomography: different phantoms Avaliação da qualidade de imagem na tomografia computadorizada:
Using light scattering method to find The surface tension of water
Experiment (8) Using light scattering method to find The surface tension of water The aim of work: The goals of this experiment are to confirm the relationship between angular frequency and wave vector
DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND
DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND THE THREE-DIMENSIONAL DISTRIBUTION OF THE RADIANT FLUX DENSITY AT THE FOCUS OF A CONVERGENCE BEAM
SUITABILITY OF RELATIVE HUMIDITY AS AN ESTIMATOR OF LEAF WETNESS DURATION
SUITABILITY OF RELATIVE HUMIDITY AS AN ESTIMATOR OF LEAF WETNESS DURATION PAULO C. SENTELHAS 1, ANNA DALLA MARTA 2, SIMONE ORLANDINI 2, EDUARDO A. SANTOS 3, TERRY J. GILLESPIE 3, MARK L. GLEASON 4 1 Departamento
DEVELOPMENT AND IMPLEMENTATION OF AN AUTOMATED SYSTEM TO EXCHANGE ATTENUATORS OF THE OB85/1 GAMMA IRRADIATOR
2011 International Nuclear Atlantic Conference - INAC 2011 Belo Horizonte,MG, Brazil, October 24-28, 2011 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-04-5 DEVELOPMENT AND IMPLEMENTATION
DETERMINATION OF THE EFFECTIVE VOLUME OF AN EXTRAPOLATION CHAMBER FOR X-RAY DOSIMETRY
X Congreso Regional Latinoamericano IRPA de Protección y Seguridad Radiológica Radioprotección: Nuevos Desafíos para un Mundo en Evolución Buenos Aires, 12 al 17 de abril, 2015 SOCIEDAD ARGENTINA DE RADIOPROTECCIÓN
Fiber Optics: Fiber Basics
Photonics Technical Note # 21 Fiber Optics Fiber Optics: Fiber Basics Optical fibers are circular dielectric wave-guides that can transport optical energy and information. They have a central core surrounded
DOSIMETRIC CHARACTERIZATION OF DYED PMMA SOLID DOSIMETERS FOR GAMMA RADIATION
2005 International Nuclear Atlantic Conference - INAC 2005 Santos, SP, Brazil, August 28 to September 2, 2005 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 85-99141-01-5 DOSIMETRIC CHARACTERIZATION
Will Your Fiber Optic Cable Plant Support Gigabit Ethernet?
Will Your Fiber Optic Cable Plant Support Gigabit Ethernet? GBE, as the name says, is Ethernet scaled up to gigabit speeds, providing a migration path from Ethernet at 10 MB/s to Fast Ethernet at 100 MB/s
INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.
INTRODUCTION Fibre optics behave quite different to metal cables. The concept of information transmission is the same though. We need to take a "carrier" signal, identify a signal parameter we can modulate,
P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)
INSURANCE SCAM OPTICS - LABORATORY INVESTIGATION P R E A M B L E The original form of the problem is an Experimental Group Research Project, undertaken by students organised into small groups working as
Experiment #5: Qualitative Absorption Spectroscopy
Experiment #5: Qualitative Absorption Spectroscopy One of the most important areas in the field of analytical chemistry is that of spectroscopy. In general terms, spectroscopy deals with the interactions
WAVELENGTH OF LIGHT - DIFFRACTION GRATING
PURPOSE In this experiment we will use the diffraction grating and the spectrometer to measure wavelengths in the mercury spectrum. THEORY A diffraction grating is essentially a series of parallel equidistant
PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.
PHYS 222 Spring 2012 Final Exam Closed books, notes, etc. No electronic device except a calculator. NAME: (all questions with equal weight) 1. If the distance between two point charges is tripled, the
Continuing Medical Education Program: a credit system evaluation
Original Article Continuing Medical Education Program: a credit system evaluation Programa de Educação Médica Continuada: avaliação de um sistema de créditos Claudio Schvartsman 1, Milton Glezer 2, Renato
Fiber Optic Specifications
Fiber Optic Specifications All Fiber Optic shall be Corning Altos Single Mode OS1 Outdoor Loose Tube Gel Free Cable Corning Fiber Products only will be accepted and no substitutions or alternates will
Optical Communications
Optical Communications Telecommunication Engineering School of Engineering University of Rome La Sapienza Rome, Italy 2005-2006 Lecture #2, May 2 2006 The Optical Communication System BLOCK DIAGRAM OF
Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm
Progress In Electromagnetics Research Symposium Proceedings, Taipei, March 5 8, 3 359 Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm Yoshito Sonoda, Takashi Samatsu, and
FIBER OPTIC ISOLATORS
Features: >0W Optical power handling capability Polarization Sensitive and Insensitive versions Product offerings over 3 000 nm wavelength range High isolation levels and low return loss Low Insertion
TA3 Dosimetry and Instrumentation. Evaluation of the Field Size in Dental Diagnostic Radiology System ANDRADE PS 1, POTIENS MP 1
TA3 Dosimetry and Instrumentation Evaluation of the Field Size in Dental Diagnostic Radiology System ANDRADE PS 1, POTIENS MP 1 1 Instituto de Pesquisas Energéticas e Nucleares, São Paulo, Brazil. ABSTRACT
5-Axis Test-Piece Influence of Machining Position
5-Axis Test-Piece Influence of Machining Position Michael Gebhardt, Wolfgang Knapp, Konrad Wegener Institute of Machine Tools and Manufacturing (IWF), Swiss Federal Institute of Technology (ETH), Zurich,
DIODE PUMPED CRYSTALASER
DIODE PUMPED CRYSTALASER Ultra-compact CW & Pulsed Turnkey Systems UV Visible to IR High Reliability High Stability High Efficiency TEMoo & SLM Low Noise Low Cost ULTRA-COMPACT DIODE-PUMPED CRYSTAL LASER
104 Practice Exam 2-3/21/02
104 Practice Exam 2-3/21/02 1. Two electrons are located in a region of space where the magnetic field is zero. Electron A is at rest; and electron B is moving westward with a constant velocity. A non-zero
ENERGETIC EFFICIENCY OF AN AGRICULTURAL TRACTOR IN FUNCTION OF TIRE INFLATION PRESSURE
ENERGETIC EFFICIENCY OF AN AGRICULTURAL TRACTOR IN FUNCTION OF TIRE INFLATION PRESSURE LEONARDO DE A. MONTEIRO 1, DANIEL ALBIERO 2, KLEBER P. LANÇAS 3, ANDRÉ V. BUENO 4, FABRICIO C. MASIERO 5 ABSTRACT:
Diffraction of Laser Light
Diffraction of Laser Light No Prelab Introduction The laser is a unique light source because its light is coherent and monochromatic. Coherent light is made up of waves, which are all in phase. Monochromatic
PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER
PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER Lufan Zou and Taha Landolsi OZ Optics Limited, 219 Westbrook Road, Ottawa, ON, Canada, K0A 1L0 E-mail:
Temperature. LumaSense Technologies, Inc. supplies a unique selection of very precise calibration
Temperature Calibration Sources Highly accurate calibration equipment for pyrometers, thermal imaging cameras, radiometers, heatflux and spectrographic measurement sytems. Calibration sources are infrared
Diffraction of a Circular Aperture
Diffraction of a Circular Aperture Diffraction can be understood by considering the wave nature of light. Huygen's principle, illustrated in the image below, states that each point on a propagating wavefront
NEAR FIELD OPTICAL MICROSCOPY AND SPECTROSCOPY WITH STM AND AFM PROBES
Vol. 93 (1997) A CTA PHYSICA POLONICA A No. 2 Proceedings of the 1st International Symposium on Scanning Probe Spectroscopy and Related Methods, Poznań 1997 NEAR FIELD OPTICAL MICROSCOPY AND SPECTROSCOPY
Optical Fiber Switches
Optical Fiber Switches volume 2 contents 1 introduction 3 Piezo electrically driven optical switches 3 2 technology 4 Important parameters to characterize an optical fi ber switch 4 Multimode switches
MICROSTRUCTURAL AND MECHANICAL CHARACTERIZATION OF GRAY CAST IRON AND AlSi ALLOY AFTER LASER BEAM HARDENING
Materials Science Forum Vols. 638-642 (2010) pp 769-774 Online available since 2010/Jan/12 at www.scientific.net (2010) Trans Tech Publications, Switzerland doi:10.4028/www.scientific.net/msf.638-642.769
Module 13 : Measurements on Fiber Optic Systems
Module 13 : Measurements on Fiber Optic Systems Lecture : Measurements on Fiber Optic Systems Objectives In this lecture you will learn the following Measurements on Fiber Optic Systems Attenuation (Loss)
Polarization of Light
Polarization of Light References Halliday/Resnick/Walker Fundamentals of Physics, Chapter 33, 7 th ed. Wiley 005 PASCO EX997A and EX999 guide sheets (written by Ann Hanks) weight Exercises and weights
Lab 9: The Acousto-Optic Effect
Lab 9: The Acousto-Optic Effect Incoming Laser Beam Travelling Acoustic Wave (longitudinal wave) O A 1st order diffracted laser beam A 1 Introduction qb d O 2qb rarefractions compressions Refer to Appendix
SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
AS COMPETITION PAPER 2008
AS COMPETITION PAPER 28 Name School Town & County Total Mark/5 Time Allowed: One hour Attempt as many questions as you can. Write your answers on this question paper. Marks allocated for each question
Digital Television Broadcasting Systems Testing in Brazil
Digital Television Broadcasting Systems Testing in Brazil Kiev, Ukraine - 13-15 November 2000 Interregional Seminar on the Transition from SECAM to Digital TV Broadcasting Renato Maroja - [email protected]
View of ΣIGMA TM (Ref. 1)
Overview of the FESEM system 1. Electron optical column 2. Specimen chamber 3. EDS detector [Electron Dispersive Spectroscopy] 4. Monitors 5. BSD (Back scatter detector) 6. Personal Computer 7. ON/STANDBY/OFF
Single Mode Fiber Lasers
Single Mode Fiber Lasers for Industrial and Scientific Applications T h e P o w e r t o T r a n s f o r m T M IPG s Single Mode Fiber Lasers Advantages IPG's YLR-SM Series represents a break-through generation
OPTICAL FIBERS INTRODUCTION
OPTICAL FIBERS References: J. Hecht: Understanding Fiber Optics, Ch. 1-3, Prentice Hall N.J. 1999 D. R. Goff: Fiber Optic Reference Guide (2 nd ed.) Focal Press 1999 Projects in Fiber Optics (Applications
HYBRID INTELLIGENT SUITE FOR DECISION SUPPORT IN SUGARCANE HARVEST
HYBRID INTELLIGENT SUITE FOR DECISION SUPPORT IN SUGARCANE HARVEST FLÁVIO ROSENDO DA SILVA OLIVEIRA 1 DIOGO FERREIRA PACHECO 2 FERNANDO BUARQUE DE LIMA NETO 3 ABSTRACT: This paper presents a hybrid approach
Determination of the Effective Energy in X-rays Standard Beams, Mammography Level
Determination of the Effective Energy in X-rays Standard Beams, Mammography Level Eduardo de Lima Corrêa 1, Vitor Vivolo 1, Maria da Penha A. Potiens 1 1 Instituto de Pesquisas Energéticas e Nucleares
Infrared Viewers. Manual
Infrared Viewers Manual Contents Introduction 3 How it works 3 IR viewer in comparison with a CCD camera 4 Visualization of infrared laser beam in mid-air 4 Power Density 5 Spectral sensitivity 6 Operation
Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus
Please do not remove this manual from from the lab. It is available at www.cm.ph.bham.ac.uk/y2lab Optics Introduction Optical fibres are widely used for transmitting data at high speeds. In this experiment,
HARVESTING AND WOOD TRANSPORT PLANNING WITH SNAP III PROGRAM (Scheduling and Network Analysis Program) IN A PINE PLANTATION IN SOUTHEAST BRAZIL 1
Harvesting and Wood Transport Planning with SNAP III... 831 HARVESTING AND WOOD TRANSPORT PLANNING WITH SNAP III PROGRAM (Scheduling and Network Analysis Program) IN A PINE PLANTATION IN SOUTHEAST BRAZIL
Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI
Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI I. Background theory. 1. Electromagnetic waves and their properties. 2. Polarisation of light: a) unpolarised
DOE Solar Energy Technologies Program Peer Review. Denver, Colorado April 17-19, 2007
DOE Solar Energy Technologies Program Peer Review Evaluation of Nanocrystalline Silicon Thin Film by Near-Field Scanning Optical Microscopy AAT-2-31605-05 Magnus Wagener and George Rozgonyi North Carolina
XXIX ENFMC - Annals of Optics 2006. 3D shadowgram projection using a simple diffractive screen José J. Lunazzi, Noemí I. Rivera Rodríguez.
3D shadowgram projection using a simple diffractive screen José J. Lunazzi, Noemí I. Rivera Rodríguez. Universidade Estadual de Campinas - Instituto de Física [email protected], [email protected]
It has long been a goal to achieve higher spatial resolution in optical imaging and
Nano-optical Imaging using Scattering Scanning Near-field Optical Microscopy Fehmi Yasin, Advisor: Dr. Markus Raschke, Post-doc: Dr. Gregory Andreev, Graduate Student: Benjamin Pollard Department of Physics,
Experiment 5. Lasers and laser mode structure
Northeastern University, PHYS5318 Spring 2014, 1 1. Introduction Experiment 5. Lasers and laser mode structure The laser is a very important optical tool that has found widespread use in science and industry,
Smart Electromagnetic Flowmeter Open channel Flowmeter Detector
Magne3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIE The Magne3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter mainly used for flow
Fraunhofer Diffraction
Physics 334 Spring 1 Purpose Fraunhofer Diffraction The experiment will test the theory of Fraunhofer diffraction at a single slit by comparing a careful measurement of the angular dependence of intensity
CREOL, College of Optics & Photonics, University of Central Florida
OSE6650 - Optical Properties of Nanostructured Materials Optical Properties of Nanostructured Materials Fall 2013 Class 3 slide 1 Challenge: excite and detect the near field Thus far: Nanostructured materials
Measuring Laser Power and Energy Output
Measuring Laser Power and Energy Output Introduction The most fundamental method of checking the performance of a laser is to measure its power or energy output. Laser output directly affects a laser s
v = fλ PROGRESSIVE WAVES 1 Candidates should be able to :
PROGRESSIVE WAVES 1 Candidates should be able to : Describe and distinguish between progressive longitudinal and transverse waves. With the exception of electromagnetic waves, which do not need a material
Measuring of optical output and attenuation
Measuring of optical output and attenuation THEORY Measuring of optical output is the fundamental part of measuring in optoelectronics. The importance of an optical power meter can be compared to an ammeter
Accurately Testing fibre Optic Cables
Accurately Testing fibre Optic Cables Note: You need to know what we mean when we say accurate that the measurement made gives a value close to the real value. Standards people prefer we refer to the uncertainty
Alignement of a ring cavity laser
Alignement of a ring cavity laser 1 Introduction This manual describes a procedure to align the cavity of our Ti:Sapphire ring laser and its injection with an Argon-Ion pump laser beam. The setup is shown
Interference. Physics 102 Workshop #3. General Instructions
Interference Physics 102 Workshop #3 Name: Lab Partner(s): Instructor: Time of Workshop: General Instructions Workshop exercises are to be carried out in groups of three. One report per group is due by
UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES
UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES SEPTEMBER 2012, V 1.1 4878 RONSON CT STE K SAN DIEGO, CA 92111 858-565 - 4227 NANOCOMPOSIX.COM Note to the Reader: We at nanocomposix have published this
Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications
Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications Saulius Marcinkevičius Optics, ICT, KTH 1 Outline Optical near field. Principle of scanning near field optical microscope
Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy
Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy UV/VIS AND UV/VIS/NIR SPECTROSCOPY A P P L I C A T I O N N O T E Introduction The availability and applications of fiber optic sampling in UV/Vis
PROVE, the next generation registration metrology tool, status report
PROVE, the next generation registration metrology tool, status report Dirk Beyer a, Patricia Gabella b, Greg Hughes b, Gerd Klose c, Norbert Rosenkranz a a Carl Zeiss SMS GmbH (Germany) Carl-Zeiss-Promenade
Harmonic oscillations of spiral springs Springs linked in parallel and in series
.3.26 Related topics Spring constant, Hooke s Law, oscillations, limit of elasticity, parallel springs, serial springs, use of an interface. Principle and task The spring constant D is determined for different
arxiv:cond-mat/0308498v1 [cond-mat.soft] 25 Aug 2003
1 arxiv:cond-mat/38498v1 [cond-mat.soft] 2 Aug 23 Matter-wave interference, Josephson oscillation and its disruption in a Bose-Einstein condensate on an optical lattice Sadhan K. Adhikari Instituto de
Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.
Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM. Some limitations (disadvantages) of NSOM A trade-off
High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering
High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering Power spectrum development with heterodyne technology advances biotechnology and nanotechnology measurements. M. N. Trainer
Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs
Spectroscopy Biogeochemical Methods OCN 633 Rebecca Briggs Definitions of Spectrometry Defined by the method used to prepare the sample 1. Optical spectrometry Elements are converted to gaseous atoms or
SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS
Features: SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS Low insertion loss < 0.2 db Excellent repeatability FC/PC, SC, ST, LC, MU, E2000 termination available Custom ferrule termination available Designed
Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces
Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces WP1281 Issued: November 2015 Supersedes: 2012 Author: Dr. Russell Ellis ISO 9001 Registered Background
SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II
BLUE SKY RESEARCH The SpectraTec II, two wavelength laser module is a highly integrated system comprised of two lasers, individual driving and temperature control electronics, wavelength combining, and
Raman Spectroscopy Basics
Raman Spectroscopy Basics Introduction Raman spectroscopy is a spectroscopic technique based on inelastic scattering of monochromatic light, usually from a laser source. Inelastic scattering means that
Acousto-optic modulator
1 of 3 Acousto-optic modulator F An acousto-optic modulator (AOM), also called a Bragg cell, uses the acousto-optic effect to diffract and shift the frequency of light using sound waves (usually at radio-frequency).
8001782 Owner s Manual
8001782 Digital Infrared Thermometer Owner s Manual Introduction This instrument is a portable, easy to use compact-size digital thermometer with laser sighting designed for one hand operation. The meter
Using the Spectrophotometer
Using the Spectrophotometer Introduction In this exercise, you will learn the basic principals of spectrophotometry and and serial dilution and their practical application. You will need these skills to
SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS
Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (MOBILE RADIOGRAPHY)
Beam shaping to generate uniform Laser Light Sheet and Linear Laser Spots
Beam shaping to generate uniform Laser Light Sheet and Linear Laser Spots Alexander Laskin, Vadim Laskin AdlOptica GmbH, Rudower Chaussee 29, 12489 Berlin, Germany ABSTRACT Generation of Laser Light Sheet
ArcHC_3D research case studies (FCT:PTDC/AUR/66476/2006) Casos de estudo do projecto ArcHC_3D (FCT:PTDC/AUR/66476/2006)
ArcHC_3D research case studies (FCT:PTDC/AUR/66476/2006) Casos de estudo do projecto ArcHC_3D (FCT:PTDC/AUR/66476/2006) 1 Casa de Valflores - Loures 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Capela de S. Frutuoso
Theremino System Theremino Spectrometer Technology
Theremino System Theremino Spectrometer Technology theremino System - Theremino Spectrometer Technology - August 15, 2014 - Page 1 Operation principles By placing a digital camera with a diffraction grating
Example of SOP for IR Laser
Example of SOP for IR Laser Standard Operating Procedures (SOP) for Class 4 HPD semiconductor Laser Manufacturer HPD Building & Room Number EH&S 101 Model Number HPD-1/100/975 Laser Class 4 Serial Number
Lecture 3: Fibre Optics
Lecture 3: Fibre Optics Lecture aims to explain: 1. Fibre applications in telecommunications 2. Principle of operation 3. Single- and multi-mode fibres 4. Light losses in fibres Fibre is a transparent
Asian Journal of Food and Agro-Industry ISSN 1906-3040 Available online at www.ajofai.info
As. J. Food Ag-Ind. 008, (0), - Asian Journal of Food and Agro-Industry ISSN 906-00 Available online at www.ajofai.info Research Article Analysis of NIR spectral reflectance linearization and gradient
Color holographic 3D display unit with aperture field division
Color holographic 3D display unit with aperture field division Weronika Zaperty, Tomasz Kozacki, Malgorzata Kujawinska, Grzegorz Finke Photonics Engineering Division, Faculty of Mechatronics Warsaw University
Optical coherence tomography as a tool for non destructive quality control of multi-layered foils
Optical coherence tomography as a tool for non destructive quality control of multi-layered foils Günther Hannesschläger, Alexandra Nemeth, Christian Hofer, Christian Goetzloff, Jens Reussner, Karin Wiesauer,
Near-field scanning optical microscopy (SNOM)
Adviser: dr. Maja Remškar Institut Jožef Stefan January 2010 1 2 3 4 5 6 Fluorescence Raman and surface enhanced Raman 7 Conventional optical microscopy-limited resolution Two broad classes of techniques
ESCOAMENTO DO AR EM ARMAZÉM GRANELEIRO DE GRANDE PORTE COM SISTEMA DE AERAÇÃO SIMULATION OF AIR FLOW IN LARGE AERATED GRAIN STORAGE
ESCOAMENTO DO AR EM ARMAZÉM GRANELEIRO DE GRANDE PORTE COM SISTEMA DE AERAÇÃO Oleg Khatchatourian 1 Antonio Rodrigo Delepiane de Vit 2 João Carlos Cavalcanti da Silveira 3 Luciano Ferreira 4 RESUMO Foi
MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM
MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM João Antônio Palma Setti, [email protected] Pontifícia Universidade Católica do Paraná / Rua Imaculada
L-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
Optical laser beam scanner lens relay system
1. Introduction Optical laser beam scanner lens relay system Laser beam scanning is used most often by far in confocal microscopes. There are many ways by which a laser beam can be scanned across the back
A Guide to Acousto-Optic Modulators
A Guide to Acousto-Optic Modulators D. J. McCarron December 7, 2007 1 Introduction Acousto-optic modulators (AOMs) are useful devices which allow the frequency, intensity and direction of a laser beam
EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab
EXPERIMENT O-6 Michelson Interferometer Abstract A Michelson interferometer, constructed by the student, is used to measure the wavelength of He-Ne laser light and the index of refraction of a flat transparent
