1 3. APTA PR-E-RP Recommended Practice for Load Testing of Diesel Engines Approved January 22, 1998 APTA PRESS Task Force Authorized March 17, 1999 APTA Commuter Rail Executive Committee Abstract: This recommended practice adapted from Association of American Railroads RP-545, Testing of Electrical Components establishes a standard procedure, within practical limits, for determining the performance of a diesel engine either to determine condition of equipment as a guide to required repairs or after initial assembly, major overhaul, or repairs affecting the performance of the equipment. Keywords: load testing, diesel engines, horsepower Copyright 1998 by The American Public Transportation Association 1666 K Street, N. W. Washington, DC, 20006, USA No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of The American Public Transportation Association. 3.0
2 Participants The American Public Transportation Association (APTA) greatly appreciates the contributions of the following individual(s), who provided the primary effort in the drafting of the Recommended Practice for Load Testing of Diesel Engines: Craig Prudian At the time that this recommended practice was completed, the Passenger Rail Equipment Safety Standards (PRESS) Electrical Committee included the following members: Doug Warner, Chair Gilbert L. Bailey Brad Barkman Ronald Bartels Richard Benjamin Dick Bruss Daniel L. Davis James Dietz Dave Elliott Hassan A. Fazli Bert Gagne Peter Hale Carl C. Herrmann Stephen Hilbert LeRoy D. Jones Brian Ley Otto Masek Rich Mazur Chuck Olson David Phelps Craig Prudian George Scerbo Ike Tingos Steve Zuiderveen 3.1
3 Contents 1. Overview Scope Purpose References Definitions, abbreviations, and acronyms Definitions Technical information Test set-up Loading of engine Instruments Procedure Permissible variation Adjustment of results to standard conditions
4 APTA PR-E-RP Recommended Practice for Load Testing of Diesel Engines 1. Overview 1.1 Scope This recommended practice covers load testing and determining horsepower output of diesel engines. The passenger rail industry phased this recommended practice into practice over the sixmonth period from July 1 to December 31, The recommended practice took effect January 1, Purpose This recommended practice establishes a standard procedure, within practical limits, for determining the performance of a diesel engine under the following conditions: a) After initial assembly, major overhaul, or repairs affecting the performance of the equipment; b) To determine condition of equipment as a guide to required repairs; or c) To test equipment as required by items in equipment inspection reports. 2. References IEEE Std , The IEEE Standard Dictionary of Electrical and Electronics Terms 3. Definitions, abbreviations, and acronyms 3.1 Definitions For the purposes of this recommended practice, the following terms and definitions apply. IEEE Std , The IEEE Standard Dictionary of Electrical and Electronics Terms, should be referenced for terms not defined in this clause brake horsepower: The mechanical crankshaft output of the diesel power plant, equal to traction horsepower plus auxiliary load horsepower main generator: That engine-driven generator (including direct current generators and alternator-rectifier combinations) whose output provides the traction power to the propulsion system. (Note: Because some models of main generator contain both a traction and an auxiliary portion, the term main traction generator is herein used where ambiguity or confusion might result.) 3.3
5 3.1.3 traction horsepower: The rating for a diesel power plant which is the manufacturer s guaranteed input to the main generator for traction purposes at standard conditions. Auxiliaries are operated at nominal loads as specified by the manufacturer, except (1) air compressor is unloaded and (2) no power is supplied for head end power or other train service. 4. Technical information 4.1 Test set-up With diesel engine in locomotive. With diesel engine on a test rack. 4.2 Loading of engine When the engine is tested in place on the locomotive, horsepower readings should be adjusted to the standard test conditions as described in 4.6. The main traction generator should be loaded by means of a water rheostat or resistance grid bank of sufficient capacity to load the generator to its maximum rated capacity plus any overload permitted by the manufacturer. When the engine is tested in a rack, it may be connected to its companion main generator, special test generator, or a suitable dynamometer. If a main generator is used, suitable arrangements must be made to provide the required auxiliary load. The main generator load may be provided by water rheostats, resistance grids or any other suitable means. When special generators or dynamometers are used, they should be of sufficient capacity to permit loading them to include maximum generator capacity plus auxiliary load for the largest power plant to be tested. 4.3 Instruments Data can be as comprehensive as the individual railroad s desire. Figure 1 shows a sample of horsepower curves. These curves are typical for the nominal ratings shown. Consult specific manufacturer specifications for upper and lower corner point limits applicable to specific locomotive models. When a test rack is used, suitable test instruments are generally available for use of permanent test generators or dynamometers and the readings can readily be converted to horsepower output at the engine coupling. When an engine is tested with its companion main generator, the principal readings will be those of generator volts, amperes and engine speed. The manufacturer s ratings are generally based on some standard conditions of altitude, air and fuel temperature and specific gravity of the fuel. When such adjustment is desired, suitable test thermometers, hydrometers and barometers will be required. 3.4
6 Figure 1 Typical Load Current D.C. Amperes When tested in place on the locomotives, test voltmeters and ammeters or, if desired, a wattmeter and a suitable tachometer must be used. Again, adjustments to standard conditions can be made by taking readings of specific gravity of fuel, air and fuel temperatures and making correction for the altitude of the point of test. 3.5
7 4.4 Procedure Load testing of newly overhauled engines must be preceded by a sufficient number of runs at no load and partial load to insure that all parts are in good condition or functioning properly and to insure that the engine and generator or other loading device have reached uniform and correct operating temperatures. Initial runs should comply with manufacturers engine break-in procedures and schedules. Load testing of engines likewise must be carried out with all equipment thoroughly warmed up and at uniform operating temperature. Tests can be made at partial load and/or full loads as required for the purpose intended. Load test readings should be taken over a period of time sufficient to obtain average values. Where specific requirements of any test exceed the continuous current ratings of the generator, the generator short time limits should not be exceeded. Horsepower at the output of the main traction generator can be determined as follows: Main traction generator output horsepower = Gen. Volts X Gen. Amps 746 or, where the output is read in watts: Main traction generator output horsepower = Watts 746 If the generator efficiency curve is available, horsepower input into the main traction generator can be found thus: Traction horsepower at Engine - Generator Coupling = Main Traction Generator hp Traction Generator Efficiency As an alternate to the above formula, where the approximate results will suffice, the following may be used: Traction horsepower at = Gen. Volts X Gen. Amps Engine - Generator Coupling 700 Brake horsepower of the engine can be determined as follows: Brake horsepower = Main Traction Generator hp +Auxiliary Load hp Generator Efficiency Figure 1 shows the relationship between main generator volt-ampere output and engine horsepower input to the main generator for representative locomotive types. The typical generator efficiency has been taken into account on each of these curves. Prior to test, all items of mechanical and electrical equipment must be properly adjusted for full load conditions as required by builder specifications and instructions. 3.6
8 4.5 Permissible variation Engines of the same type vary in output; this variance must be taken into account. Output of diesel power plants tested to determine their condition shall be subject to such permissible variation of rated output as may be specified by the engine manufacturer or the individual railroad. 4.6 Adjustment of results to standard conditions Engines are usually rated at: 1. Sea level to 1000 feet (289 m) 2. Air temperature 60E F (15.5E C) 3. Fuel temperature 60E F (15.5E C) 4. Specific gravity of fuel The engine builder s charts can be used to adjust results of tests to standard conditions by railroads desiring this refinement. For determining total horsepower of the diesel engine adjusted to standard conditions, the following may be used: Total horsepower = Brake Horsepower Standard Conditions Adjustment 3.7
16. APTA PR-IM-S-016-02 Standard for Pantograph Current Collection Equipment Periodic Inspection and Maintenance
16. APTA PR-IM-S-016-02 Standard for Pantograph Current Collection Equipment Periodic Inspection and Maintenance Approved October 30, 2002 APTA Passenger Rail Equipment Safety Standards Task Force Authorized
UPS Applications and VRLA Battery Sizing
TECHNICAL BULLETIN 41-7334 UPS Applications and VRLA Battery Sizing 41-7334/0213/CD www.cdtechno.com The uninterruptable power system (UPS) is used to protect critical equipment and processes from the
17. APTA PR-IM-S-017-02 Standard for Third Rail Current Collection Equipment Periodic Inspection and Maintenance
17. APTA PR-IM-S-017-02 Standard for Third Rail Current Collection Equipment Periodic Inspection and Maintenance Approved October 30, 2002 APTA Passenger Rail Equipment Safety Standards Task Force Authorized
By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document
By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has
Buck - Boost Transformers
Buck - Boost Transformers Contents Buck - Boost Transformers - Terms & Definitions... 48 Buck - Boost Transformers - Sizing... 50 Quick Reference Chart - 08, 0, 40 Volts Single & Three Phase... 5 Single
How To Select A Solid State Relay For A Three Phase Resistive Load
pero 1 Three Phase Solid State Relays & Their Application in Three Phase Heating Circuits By Paul Bachman, Fellow Engineer, Dr. Oscar Montero, R&D Manager, and Doug Sherman, FSAE Manager, Crydom, Inc.
Digital Energy ITI. Instrument Transformer Basic Technical Information and Application
g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER
Direct Current Motors
Direct Current Motors DC MOTORS The DC machine can operate as a generator and as a motor. Chap 5. Electrical Machines by Wildi, 6 e Lecturer: R. Alba-Flores Alfred State College Spring 2008 When a DC machine
Hybrid shunter locomotive
Hybrid shunter locomotive 1 Hervé GIRARD, Presenting Author, 2 Jolt Oostra, Coauthor, 3 Joerg Neubauer, Coauthor Alstom Transport, Paris, France 1 ; Alstom Transport, Ridderkerk, Netherlands 2 ; Alstom
Federal Wage System Job Grading Standards for Electric Power Controlling, 5407. Table of Contents
Federal Wage System Job Grading Standards for Electric Power Controlling, 5407 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 SPECIAL ADDITIONAL RESPONSIBILITIES...
Creating a Transit Asset Management Program
A P T A S T A N D A R D S D E V E L O P M E N T P R O G R A M RECOMMENDED PRACTICE American Public Transportation Association 1666 K Street, NW, Washington, DC, 20006-1215 APTA-SGR-TAM-RP-001-13 Approved
NY State Rail Summit Alstom Transportation Inc.
NY State Rail Summit Alstom Transportation Inc. Chuck Wochele 06/14/2010 Two main activities 19.7 Billion Euro s in Sales (2009 FY) 81,500 Employees 70 countries Power Sector 13 Billion Euro Transport
Standard for a Continuity of Operations Plan for Transit Agencies
APTA STANDARDS DEVELOPMENT PROGRAM STANDARD American Public Transportation Association 1666 K Street, NW, Washington, DC, 20006-1215 APTA-SS-SEM-S-001-08 Rev. 1 Rev. 1: April 1, 2013 Published: September
Renewable Energy Laboratory for Engineering Students
dspace User Conference 2010 India Sept 24 th 10 Renewable Energy Laboratory for Engineering Students H.T Jadhav, S. D. Joshi Rajarambapu Institute Of Technology ABSTRACT Renewal Energy is now included
Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.
Lab 9: Synchronous motor. Objective: to examine the design of a 3-phase synchronous motor; to learn how to connect it; to obtain its starting characteristic; to determine the full-load characteristic of
(Issued 1 Dec. 1965) CRD-C 45-65 METHOD OF TEST FOR THERMAL CONDUCTIVITY OF LIGHTWEIGHT INSULATING CONCRETE 1
CRD-C 45-65 METHOD OF TEST FOR THERMAL CONDUCTIVITY OF LIGHTWEIGHT INSULATING CONCRETE 1 Scope 1. This method of test covers a procedure for measuring the thermal conductivity of lightweight concrete of
The State Fire Marshal's Office and the VDH/Office of Licensure and Certification. Generator Testing in Nursing Facilities
Generator Testing in Nursing Facilities Introduction Recent emergencies and natural disasters have emphasized the need to ensure that nursing facilities have an adequate EPSS in place should the loss of
Federal Wage System Job Grading Standard for Powered Support Systems Mechanic, 5378. Table of Contents
Federal Wage System Job Grading Standard for Powered Support Systems Mechanic, 5378 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 GRADES... 2 TITLES... 3 HELPER AND INTERMEDIATE JOBS... 3 NOTE
Application Information
Moog Components Group manufactures a comprehensive line of brush-type and brushless motors, as well as brushless controllers. The purpose of this document is to provide a guide for the selection and application
Recommended Practice for Installation of Transit Vehicle Fire Protection Systems
Recommended Practice for Installation of Transit Vehicle Fire Protection Systems Approved October 25, 2007 APTA Fire Safety Working Group Approved May 3, 2008 APTA Bus Safety Committee Approved October
6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20
USE OF ELECTRICAL TEST EQUIPMENT Test equipment is necessary for determining proper set-up, adjustment, operation, and maintenance of electrical systems and control panels. The following is a general procedure
Table 10-1 Travel Times Between Stations 1 10. OPERATING & MAINTENANCE PLAN
10. OPERATING & MAINTENANCE PLAN This section describes an operating plan that responds directly to anticipated commuter ridership patterns. Train schedules, type and capacity of rolling stock, and likely
Constant Voltage Charger Selection for VRLA Batteries
TECHNICAL BULLETIN 41-2129 Constant Voltage Charger Selection for VRLA Batteries Please Note: The information in this technical bulletin was developed for C&D Dynasty 12 Volt VRLA products. While much
How to measure absolute pressure using piezoresistive sensing elements
In sensor technology several different methods are used to measure pressure. It is usually differentiated between the measurement of relative, differential, and absolute pressure. The following article
Product Development. Using Critical Path EVM for the Microsoft Project Desktop Application Readme
Product Development Using Critical Path EVM for the Microsoft Project Desktop Application Readme Published: June 2009 Table of Contents Introduction... 1 System Requirements... 1 Installing the Critical
Mixing Sodium and Lead Battery Technologies in Telecom Applications
Mixing Sodium and Lead Battery Technologies in Telecom Applications Paul Smith Shanon Kolasienski Technical Marketing Manager Application Engineer GE Critical Power GE Energy Storage Plano, TX 75074 Schenectady,
ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation
ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation Ohio Medical Corporation 1111 Lakeside Drive Gurnee, IL 60031 Phone: (800) 448-0770 Fax: (847) 855-6304 [email protected]
an EnPro Industries company POWERSolutions
an EnPro Industries company POWERSolutions Steadfast Performer, Trustworthy Reliability, and Relentless Dependability The FM/ALCO engine, a world renowned name well established as a workhorse and prime
NITP 6.1 to 6.4 National Instrument Test Procedures for Non-automatic Weighing Instruments
NITP 6.1 to 6.4 National Instrument Test Procedures for Non-automatic Weighing Instruments Commonwealth of Australia 2012 NSC V 1 First edition 2000 Second edition October 2002 Third edition February 2004
Power transformers. Special transformers Railway
Power transformers Special transformers Railway A leader in railway systems Our compact and low-weight transformers fully comply with the customer s specifications. The products are developed together
WORKING DOCUMENT ON. Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS
WORKING DOCUMENT ON Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS WORKING DOCUMENT in the framework of the implementation of
Motors and Generators
Motors and Generators Electro-mechanical devices: convert electrical energy to mechanical motion/work and vice versa Operate on the coupling between currentcarrying conductors and magnetic fields Governed
Electrical Design TABLE OF CONTENTS FOREWORD... 1. BASIC ELEMENTS OF ELECTRICITY... 2 Electricity works much like water Ohm s Law
TABLE OF CONTENTS Electrical Design TABLE OF CONTENTS FOREWORD.......................................................................... 1 BASIC ELEMENTS OF ELECTRICITY..................................................
MODEL DJ-3 DRAFT INDUCER SPECIFICATIONS
MODEL DJ-3 DRAFT INDUCER Performance Curves MODEL DJ-3 S.P. CFM S.P. CFM S.P. CFM per cubic foot natural gas and for 139,000 per gallon No. 2 fuel oil. RPM 1550 Watts 35 Amps.43 Therm. Prot. Imp. Prot.
Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.
By Darrell G. Broussard, P.E. Introduction: As engineers, we are aware that electrical power systems have grown. How much have they grown? When was the last time you specified a 2400-volt system, a 4160-volt
COMPRESSION SPECIALISTS
COMPRESSION SPECIALISTS TRAINING & TECHNICAL SERVICES SINCE 1964 TABLE OF CONTENTS TRAINING Customized Courses 3 Training Courses 3 Standard Course List 4 ANALYSIS Horsepower Curve Development 6 Performance
TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES
1. Introduction TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES 1.1 This scheme details the tests and inspection of diesel engines manufactured by mass production system for use in marine
Developing and Maintaining a Customer Service Culture
APTA STANDARDS DEVELOPMENT PROGRAM RECOMMENDED PRACTICE American Public Transportation Association 1666 K Street NW Washington, DC 20006 APTA BTS-BO-RP-004-09 Published December 31, 2009 APTA Bus Operations
44. Standard for Wayside Intrusion Detection System Inspection and Testing
44. Standard for Wayside Intrusion Detection System Inspection and Testing Approved June 10, 2003 APTA Rail Transit Standards Fixed Structures Inspection and Maintenance Committee Approved September 28,
Joule Equivalent of Electrical Energy
by Dr. James E. Parks Department of Physics and Astronomy 401 Nielsen Physics Building The University of Tennessee Knoxville, Tennessee 37996-1200 Copyright October, 2013 by James Edgar Parks* *All rights
Centrifugal Fans and Pumps are sized to meet the maximum
Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed
RESIDENTIAL SERVICE SCHEDULE R
SOUTH CENTRAL POWER COMPANY Lancaster, Ohio RESIDENTIAL SERVICE SCHEDULE R AVAILABILITY AND APPLICABILITY: This South Central Power Company (Cooperative) rate schedule is available and applicable for electric
The Ins and Outs of PoE
Power over Ethernet (PoE) Advantages of PoE in Industrial Networking Applications By Brian Roth, Product Marketing Engineer The Ins and Outs of PoE Today, Power over Ethernet (PoE) has become a hot term
THE BREADBOARD; DC POWER SUPPLY; RESISTANCE OF METERS; NODE VOLTAGES AND EQUIVALENT RESISTANCE; THÉVENIN EQUIVALENT CIRCUIT
THE BREADBOARD; DC POWER SUPPLY; RESISTANCE OF METERS; NODE VOLTAGES AND EQUIVALENT RESISTANCE; THÉVENIN EQUIVALENT CIRCUIT YOUR NAME LAB MEETING TIME Reference: C.W. Alexander and M.N.O Sadiku, Fundamentals
ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products
ECM Motors Manufactured By Regal Beloit Products and Applications- What s an ECM? ECM 2.3 series ECM 142 Arktic ECM 58mm Arktic ECM 59 Arktic SSC2 Arktic 51 GEXPRO Regal Beloit s distribution arm for all
Research Report. Impact of Vehicle Weight Reduction on Fuel Economy for Various Vehicle Architectures
Impact of Vehicle Weight Reduction on Fuel Economy for Various Vehicle Architectures Research Report Conducted by Ricardo Inc. for The Aluminum Association 2008-04 Impact of Vehicle Weight Reduction on
EP 95 00 30 03 SP RAILCORP NETWORK MANAGEMENT PLAN CHAPTER 2 - CUSTOMER INSTALLATION SAFETY. Authorised by: Neal Hook Chief Engineer Electrical
Engineering Standard Electrical RAILCORP NETWORK MANAGEMENT PLAN CHAPTER 2 - CUSTOMER INSTALLATION SAFETY Owner: Approved by: Chief Engineer, Electrical Neal Hook Chief Engineer Electrical Authorised by:
2007 W-SERIES (CHEVROLET & GMC) N-SERIES (ISUZU) 250 NPR/W3500, NPR HD/W4500, NQR/W5500, NRR/W5500-HD Diesel Electrical Symbols
2007 W-SERIES (CHEVROLET & GMC) N-SERIES (ISUZU) 250 NPR/W3500, NPR HD/W4500, NQR/W5500, NRR/W5500-HD Diesel Electrical Symbols Symbol Meaning Symbol Meaning Symbol Meaning Fuse Electronic Parts Coil (Inductor),
DC MOTOR ANALYSIS & TROUBLESHOOTING
DC MOTOR ANALYSIS & TROUBLESHOOTING By Don Shaw Condition assessment of DC motors requires a basic understanding of the design and operating characteristics of the various types available: the series motor,
KINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE
ADVANCED ENGINEERING 3(2009)1, ISSN 1846-5900 KINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE Cibulka, J. Abstract: This paper deals with the design of Kinetic Energy Recovery Systems
DETERMINING ELECTRIC MOTOR LOAD AND EFFICIENCY
F A C T S H E E T a Program of the U.S. Department of Energy DETERMINING ELECTRIC MOTOR LOAD AND EFFICIENCY Most likely your operation s motors account for a large part of your monthly electric bill. Far
WINDING RESISTANCE TESTING
WINDING RESISTANCE TESTING WINDING RESISTANCE TEST SET, MODEL WRT-100 ADWEL INTERNATIONAL LTD. 60 Ironside Crescent, Unit 9 Scarborough, Ontario, Canada M1X 1G4 Telephone: (416) 321-1988 Fax: (416) 321-1991
AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5
AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC
AASHTO RR101 Webinar Equipment
Presentation to AASHTO RR101 Webinar Equipment M. Bergeron Chief Mechanical Officer April 9, 2013 Agenda Amtrak Mechanical Department Maintenance Plan & Production Capabilities Amtrak Train 5 Bull Gulch,
Standards Designation and Organization Manual
Standards Designation and Organization Manual InfoComm International Performance Standards Program Ver. 2009-1 March 27, 2009 Issued by: Joseph Bocchiaro III, Ph.D., AStd., CTS-D, CTS-I, ISF-C The Director
Miniature High-Torque, DC Servomotors and DC Gearmotors
typical applications Robotics Factory automation Medical equipment Computer peripherals and office equipment Portable, battery-operated equipment Textile machinery Packaging machinery Actuators Miniature
Implementation of the Movable Photovoltaic Array to Increase Output Power of the Solar Cells
Implementation of the Movable Photovoltaic Array to Increase Output Power of the Solar Cells Hassan Moghbelli *, Robert Vartanian ** * Texas A&M University, Dept. of Mathematics **Iranian Solar Energy
Created by: Austin Davis Neel Iyer Darcie Jones Sascha Schwarz
EMGT 587 Systems Engineering Created by: Austin Davis Neel Iyer Darcie Jones Sascha Schwarz Table of Contents Introduction... 3 Operational Scenarios... 4 1. User sets and cancels cruise control:... 4
Voltage Loss Formula s
www.litz-wire.com HM Wire International Inc. Phone: 330-244-8501 Fax: 330-244-8561 Voltage Loss Formula s www.hmwire.com Voltage loss in a wire is synonymous to pressure loss in a pipe. Electric current
Charger Output AC Ripple Voltage and the affect on VRLA batteries
TECHNICAL BULLETIN 41-2131 Charger Output AC Ripple Voltage and the affect on VRLA batteries Please Note: The information in this technical bulletin was developed for C&D Dynasty 12 Volt VRLA products.
Evolution * Series Locomotive
GE Transportation Evolution * Series Locomotive GE imagination at work Technology leadership of the Evolution Series Locomotive A closer look at the Evolution Series Locomotive reveals how GE Transportation
C18 ACERT Fire Pump Tier 3 448 bkw/600 bhp @ 1750 rpm
CATERPILLAR ENGINE SPECIFICATIONS I-6, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...183.0 mm (7.2 in) Displacement... 18.1 L (1,104.53 in3) Aspiration...Turbocharged Aftercooled Compression
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61400-2 Second edition 2006-03 Wind turbines Part 2: Design requirements for small wind turbines This English-language version is derived from the original bilingual publication
Variable Transformers Product Design & Engineering Data
Variable Transformers Product Design & Engineering Data Product Design & Engineering Data Type 1010B Cutaway General Information STACO ENERGY PRODUCTS CO. is a leading manufacturer of variable transformers,
main type of locomotive in use, but over half of those had surpassed their durable lifespan. China Afghanistan Project Sites Nepal
Pakistan Diesel Electric Locomotives Rehabilitation Project (1) and Diesel Electric Locomotives Production Project (2) External Evaluator: Hajime Sonoda Field Survey: September 2004 1 Project Profile and
Air Conditioning Sign-Off Sheet
Air Conditioning Sign-Off Sheet Printed Technician Name Address Social Security Number Telephone Number City State Zip Code Install Or Verify The Accuracy Of An Air Conditioner s Installation The candidate
Heavy Duty Equipment Mechanic (Class Code 3743) Task List. Inspection and Diagnosis
Heavy Duty Equipment Mechanic (Class Code 3743) Task List Inspection and Diagnosis In order to verify complaints and determine malfunctions a Heavy Duty Mechanic: 1. Reads operators written trouble reports,
)454 6 %,%#42)#!, #(!2!#4%2)34)#3 &/2 5."!,!.#%$ $/5",%#522%.4 ).4%2#(!.'% #)2#5)43 $!4! #/--5.)#!4)/. /6%2 4(% 4%,%0(/.%.%47/2+ )454 Recommendation 6
INTERNATIONAL TELECOMMUNICATION UNION )454 6 TELECOMMUNICATION (03/93) STANDARDIZATION SECTOR OF ITU $!4! #/--5.)#!4)/. /6%2 4(% 4%,%0(/.%.%47/2+ %,%#42)#!, #(!2!#4%2)34)#3 &/2 5."!,!.#%$ $/5",%#522%.4
Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS
Braking Resistors for Variable Frequency Drives APPLICATION AC variable frequency drives are commonly used with a general purpose AC induction motor to form a reliable variable speed drive system. For
NETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
Thermoelectric Generator (TEG) for Heavy Diesel Trucks John C. Bass, Aleksandr S. Kushch, Norbert B. Elsner Hi-Z Technology, Inc.
Thermoelectric Generator (TEG) for Heavy Diesel Trucks John C. Bass, Aleksandr S. Kushch, Norbert B. Elsner Hi-Z Technology, Inc. Abstract An improved TEG for the Heavy Duty Class Eight Diesel Trucks is
MAP-21 National Public Transportation Safety and Transit Asset Management Requirements
MAP-21 National Public Transportation Safety and Transit Asset Management Requirements Allison I. Fultz Kaplan Kirsch & Rockwell LLP Washington, DC 2013 APTA ANNUAL MEETING Chicago, IL October 1, 2013
Selecting a Centrifugal Pump to Handle a Viscous Liquid
Copyright 2002, 2005, 2008 Randall W. Whitesides, P.E. Introduction This course provides the student with an understanding of fluid viscosity and its effects on the performance of centrifugal pump operation.
Network Rail. Consultation on Traction Electricity Consumption Rates for Train Operating Companies. August 2008
Network Rail Consultation on Traction Electricity Consumption Rates for Train Operating Companies August 2008 2 1 Introduction... 3 Context & background... 3 2 Calculation of The New Electricity Consumption
Current Trends in UPS Technology. Fly Wheels
Current Trends in UPS Technology Fly Wheels 1 Current Trends in UPS Technology Fly Wheels PowerThru (Phillips Service Industries, Inc.), formerly known as Pentadyne Active Power Vycon Energy Caterpillar
AEROSPACE STANDARD. Quality Management Systems - Requirements for Aviation, Space and Defense Organizations RATIONALE
AEROSPACE STANDARD AS9100C Issued 1999-11 Revised 2009-01 Superseding AS9100B Quality Management Systems - Requirements for Aviation, Space and Defense Organizations RATIONALE This standard has been revised
How to Choose the Right Air Compressor
How to Choose the Right Air Compressor Air compressors have been around for well over 100 years and have as many uses as there are tools that use air. One reason for their popularity is because air as
The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08
Air Volume Requirement Air conditioning systems are engineered with a specific amount of indoor air passing across the surface of the evaporator coil. The amount of air is measured in cubic feet per minute.
at night Bright Who says the workday ends at 5 p.m.?
ED TURNER PHOTO BOEING AT NIGHT Bright at night Left: An enormous GE-90 engine leaves the factory near Boeing Field in south Seattle after build-up at the Propulsion Systems Division. The engine will be
Modern electrical propulsion systems for rolling stock
odern electrical propulsion systems for rolling stock Athen, January 2006 Andreas Fuchs TS GT DP Copyright Siemens AG 2005. All Rights Reserved. TS GT DP, Fuchs Folie odern electrical propulsion systems
The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:
The Charging System Charging System The charging system has two essential functions: Generate electrical power to run the vehicle s electrical systems Generate current to recharge the vehicle s battery
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.
Lab 13: Wound rotor induction motor. Objective: to examine the construction of a 3-phase wound rotor induction motor; to understand exciting current, synchronous speed and slip in this motor; to determine
What can I do with a major in Diesel Technology?
Lewis-Clark State College offers one and two year certificates, A.A.S. and B.A.S Degrees in Diesel Technology through the Technical and Industrial Division. You can learn more about the Technical and Industrial
REQUEST FOR QUOTATIONS
Metropolitan Washington Airports Authority Materials Management, MA-133 Terminal A, Room 278 Washington, DC 20001-4901 REQUEST FOR QUOTATIONS 1. FOR INFORMATION CONTACT NAME: Regina Leigh 2. REQUEST FOR
HVAC Efficiency Definitions
HVAC Efficiency Definitions Term page EER - 2 SEER - 3 COP - 4 HSPF - 5 IPLV - 6 John Mix May 2006 Carrier Corporation 1 Energy Efficiency Ratio (EER) The energy efficiency ratio is used to evaluate the
Renewable Energy Test Station (RETS) TEST PROCEDURES FOR SOLAR TUKI
Renewable Energy Test Station (RETS) TEST PROCEDURES FOR SOLAR TUKI March 2007 A. Test Procedures for Solar Tuki Lamp S. No. Test Parameters Technical Requirements Instruments Required Test Methods A.
Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines
36 Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines KEIICHI SHIRAISHI *1 YOSHIHISA ONO *2 YUKIO YAMASHITA *3 MUSASHI SAKAMOTO *3 The extremely slow steaming of ships has become
Effects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity
Effects of AC Ripple Current on VRLA Battery Life A Technical Note from the Experts in Business-Critical Continuity Introduction Given the importance of battery life to UPS system users and the fact that
Microsoft Excel Tutorial
Microsoft Excel Tutorial by Dr. James E. Parks Department of Physics and Astronomy 401 Nielsen Physics Building The University of Tennessee Knoxville, Tennessee 37996-1200 Copyright August, 2000 by James
Single-Phase AC Synchronous Generator
ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description
HP Common Slot power supply technology
Technology brief HP Common Slot power supply technology 3 rd edition Table of contents Abstract 2 Introduction 2 HP Common Slot power supplies 2 Load Balanced and High Efficiency Modes 7 Right-sizing the
SAGEON SITE MONITOR (SSM) Application Note AN103-4012-00
SAGEON SITE MONITOR (SSM) Application Note AN103-4012-00 AN 103-4012-00, Issue 2a sageon_sm-an.pdf www.unipowerco.com SALES: +1-800-440-3504 HEAD OFFICE: +1-954-346-2442 EUROPE: +44 (0)1903 768200 SAGEON