ECG Patient Cables-Unshielded
|
|
|
- Barry Preston
- 10 years ago
- Views:
Transcription
1 -Unshielded Shielding All Bioconnect Patient Cables are constructed using cable designed to exacting specifications with medical grade Santoprene (TPE) jacket, copper center conductors, PE insulation and dual shielding. This low noise cables minimizes triboelectric noise and electrical interference. Cable yokes can be made with inductors (HF Chokes) or resistors if required. Where monitors are subject to EMI or ESU interference, cables may need to be equipped with ferrite beading. Sheet Clip Anchors cable in place while in use. Flex Reliefs Robust, Santoprene flex reliefs are located at yoke, and device ends of all cables ensuring long life and reducing continuity disruption. Traceability All Patient Cables are clearly marked with part numbers and lot control information. Yoke Marking To facilitate lead attachment, cable yokes are labeled to clearly show channel designations and color codes. Safety Interface This series of three and five lead Bioconnect Patient cables are designed for use with unshielded safety DIN lead wires. Santoprene (TPE is the latex-free material chosen for use in the cables and leads. Yokes over-molds and flex reliefs are fabricated using the same TPE used in the wire and cable jackets to provide the most solid bond between cable components. This increases product life and patient comfort and safety. Santoprene can be sterilized using most common methods: steam autoclave, gamma irradiation, and EtO. It is impervious to most cleaning solutions and solvents. 3 Lead Part # Description Connector # Resistors #DB-1306 Patient Cable, GE Marquette 004 with 1 K #DB-1316 Patient Cable, GE Marquette 004 without #DB-1340 Patient Cable, AAMI 6 Pin 001 with 1 K #DB-1351 Patient Cable, AAMI 6 Pin 001 without #DB-1385 Patient Cable, Phillips (HP-Agilent) 002 with 1 K #DB-1396 Patient Cable, Phillips (17 pin ECG) 003 with 1 K Device Connectors Bioconnect stocks patient cables that are compatible with an extensive list of medical monitoring devices. All device connectors are over-molded with medical grade Santoprene and feature flexible strain reliefs for durability and ease of use. 5 Lead Part # Description Connector # Resistors #DB-1506 Patient Cable, GE Marquette 004 with 1 K #DB-1516 Patient Cable, GE Marquette 004 without #DB-1540 Patient Cable, AAMI 6 Pin 001 with 1 K #DB-1551 Patient Cable, AAMI 6 Pin 001 without #DB-1585 Patient Cable, Phillips (HP-Agilent) 002 with 1 K #DB-1596 Patient Cable, Phillips (17 pin ECG) 003 with 1 K MERCURY MEDICAL Page 95 (800) 835-MMED (727) FAX (800)
2 MERCURY MEDICAL Page 96 (800) 835-MMED (727) FAX (800)
3 MERCURY MEDICAL Page 97 (800) 835-MMED (727) FAX (800)
4 MERCURY MEDICAL Page 98 (800) 835-MMED (727) FAX (800)
5 ECG Patient Cables MERCURY MEDICAL Page 99 (800) 835-MMED (727) FAX (800)
6 MERCURY MEDICAL Page 100 (800) 835-MMED (727) FAX (800)
7 MERCURY MEDICAL Page 101 (800) 835-MMED (727) FAX (800)
8 MERCURY MEDICAL Page 102 (800) 835-MMED (727) FAX (800)
9 MERCURY MEDICAL Page 103 (800) 835-MMED (727) FAX (800)
10 ECG Patient Cables MERCURY MEDICAL Page 104 (800) 835-MMED (727) FAX (800)
11 MERCURY MEDICAL Page 105 (800) 835-MMED (727) FAX (800)
12 Reference Guide These illustrations are provided to confirm that our connector is a match for your device. Carefully count the exact number of pins or sockets. MERCURY MEDICAL Page 106 (800) 835-MMED (727) FAX (800)
13 -Shielded Cable Shielding All Bioconnect Unitized Patient Cables are constructed using fully shielded trunk cable and lead wires designed to exacting specifications with medical grade Santoprene (TPE) jackets, copper center conductors, PE insulation and dual shielding. These low noise cables and wires minimize triboelectric noise and electrical interference. Cable yokes can be made with inductors (HF Chokes) or resistors if required. Where monitors are subject to EMI or ESU interference, cables may need to be equipped with ferrite beading. Sheet Clip Anchors cable in place while in use. Flex Reliefs Robust, Santoprene flex reliefs are located at yoke, lead junctions and device ends of all unitized cables ensuring long life and reducing continuity disruption. Traceability All Patient Cables are clearly marked with part numbers and lot control information. Lead Wires Cable, yoke and lead wires are a single, molded unit which prevents accidental lead disconnection. Unitized cables are optimized for use with defibrilators, in ERs, in ICUs and Mobile Emergency Response Systems. The low profile, compact yoke is available in three and five lead models with snap and pinch lead terminations. Yoke Marking To facilitate lead attachment, cable yokes are labeled to clearly show channel designations and color codes. Santoprene (TPE is the latex-free material chosen for use in the cables and leads. Yokes over-molds and flex reliefs are fabricated using the same TPE used in the wire and cable jackets to provide the most solid bond between cable components. This increases product life and patient comfort and safety. Santoprene can be sterilized using most common methods: steam autoclave, gamma irradiation, and EtO. It is impervious to most cleaning solutions and solvents. 3 Lead Part # Description Connector # Resistors #DB-3306 Patient Cable, GE Marquette 004 with 1 K #DB-3316 Patient Cable, GE Marquette 004 without #DB-3340 Patient Cable, AAMI 6 Pin 001 with 1 K #DB-3351 Patient Cable, AAMI 6 Pin 001 without #DB-3385 Patient Cable, Phillips (HP-Agilent), Fixed 002 with 1 K #DB-3396 Patient Cable, Phillips (17 pin ECG), Fixed 003 with 1 K Device Connectors Bioconnect stocks patient cables that are compatible with an extensive list of medical monitoring devices. All device connectors are over-molded with medical grade Santoprene and feature flexible strain reliefs for durability and ease of use. 5 Lead Part # Description Connector # Resistors #DB-3506 Patient Cable, GE Marquette 004 with 1 K #DB-3516 Patient Cable, GE Marquette 004 without #DB-3540 Patient Cable, AAMI 6 Pin 001 with 1 K #DB-3551 Patient Cable, AAMI 6 Pin 001 without #DB-3585 Patient Cable, Phillips (HP-Agilent), Fixed 002 with 1 K #DB-3596 Patient Cable, Phillips (17 pin ECG), Fixed 003 with 1 K MERCURY MEDICAL Page 107 (800) 835-MMED (727) FAX (800)
Custom Cable Assemblies for Medical Applications and more.
Custom Cable Assemblies for Medical Applications and more. National Cable Molding is one of the United States premier suppliers of custom molded electrical assemblies for medical applications. Our capability
Monitoring Cables and Leadwires
Monitoring Cables and Leadwires Multi-Link ECG Cables Multi-Link ECG Cables 5-Lead ESU............ 50 Multi-Link ECG Cables 5-Lead Standard.......... 50 Multi-Link ECG Cables 3-Lead................. 51
I NTERFACE CABLE ADAPTER MODULE
I NTERFACE CABLE ADAPTER MODULE The Interface Cable Adapter Module (ICAM) has two basic uses. First, it enables you to run shielded cable between the industrial sensor interface module (SIM) and the weather
CutMaster 102. 6.04 Major External Replacement Parts
CutMaster 0 6.04 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-086 Tube, roll handle 9-0 4 Front Panel 9-087 Rear Panel 9-00 4 Art #
Kendall DL Cable and Lead Wire System. A Disposable Cardiac Monitoring Solution Designed for Superior Clinical Performance. Safe, Simple, Secure
Kendall DL Cable and Lead Wire System A Disposable Cardiac Solution Designed for Superior Clinical Performance Safe, Simple, Secure Covidien Cardiac Solutions Market Leader Covidien is a market leader
Unarmored Variable Frequency Drive (VFD) Cable Termination Guide
Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored
Chapter 1 // Computer Cables THE WORLD OF CABLES. delivery of stock goods in 24 hours. certified quality
THE WORLD OF CABLES 2012 // delivery of stock goods in 24 hours certified quality 9 own branches worldwide - global sourcing - local serving all services are online available since 42 years original ASSMANN
HARAX circular connector
Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor
Advanced RF Isolation Variable Beamwidth Antenna. Datasheet. Model: AM-V5G-Ti. Carrier-Class 2x2 MIMO PtMP BaseStation
Advanced RF Isolation Variable Beamwidth Antenna Model: AM-V5G-Ti Carrier-Class 2x2 MIMO PtMP BaseStation Adjustable Beamwidth Configuration Reduced Co-Location Interference Advanced Carrier-Class PtMP
Outdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof
Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support 1 2Datasheet Protect your
USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black
USB.0 CableS USB.0 and backwards compatible for USB.0 and. Supports high speed, 480Mbps Twisted-pair construction reduces cross talk to ensure error free transfer USB A male to USB B male 00-0 007-0 0-09-
An Ethernet Cable Discharge Event (CDE) Test and Measurement System
An Ethernet Cable Discharge Event (CDE) Test and Measurement System Wei Huang, Jerry Tichenor ESDEMC Technology LLC Rolla, MO, USA [email protected] Abstract A Cable Discharge Event (CDE) is an electrostatic
Cables and Accessories Selection Guide
Cables and Accessories Selection Guide From data centers to robotics to patient monitoring equipment, we re committed to enabling the next generation of faster, smaller and smarter design. 3M offers an
Xtra-Guard Performance Cable
Xtra-Guard Performance Cable Performance as tough as your application From the frozen tundra to the desert heat, in petrochemical plants where protection against chemicals is crucial, in motion control
Solving Signal Problems Effective shielding is key to enhancing the reliability and performance of broadcast cables.
Solving Signal Problems Effective shielding is key to enhancing the reliability and performance of broadcast cables. by Marty Van Der Burgt Belden Article for Broadcast Engineering There is perhaps no
Mobile Device Power Monitor Battery Connection Quick Start Guide
Mobile Device Power Monitor Battery Connection Quick Start Guide Distributed By: Monsoon Solutions, Inc. www.msoon.com Introduction The Power Tool software and the Mobile Device Power Monitor hardware
CutMaster 82. 6.04 Major External Replacement Parts
CutMaster 8 6.0 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-08 Tube, roll handle 9-0 Front Panel 9-07 Rear Panel 9-00 Art # A-080
East Central College 14434.03 HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE
SECTION 260519 - BUILDING WIRE AND CABLE PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Building wire and cable as shown on drawings or specified including feeders,
LocoNet, the Digitrax Difference
LocoNet, the Digitrax Difference LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout. LocoNet Compatible devices are designed to work together on
Hook-Up and Lead Wire
3.1 Hook-Up and Lead Wire 3 Table of Contents Hook-Up & Lead Wire Page Introduction: UL Style & CSA Type Listings 3.2 PVC 3.3 3.8 300V, 80 C 3.3 300V, 105 C 3.4 600V, 105 C 3.5 (Type MW) MIL-W-76C-PVC:
Waekon Gold. Test Lead Master Kit. Tight Spot Test Lead Kit. Micro Mate Terminal Adapter Set. Magnetic Test Lead Ground Lug
Sharp, adjustable depth contact tip to penetrate corrosion or metal coatings for a good connection. Limited Lifetime warranty. 1) Universal Magnetic Ground Lug Stop searching for a good place to clip your
ISO VIEW OF AX SERIES XLR CABLE CONNECTOR
ISO VIEW OF AX SERIES XLR CABLE CONNECTOR One piece ground / latch spring design incorporating twin wipe contacts for a direct connection path from mating shell to ground providing enhanced connection
UNITRONIC Data Communication Systems
Data Communication Systems 156 DeviceNet 162 PROFIBUS 168 CAN Bus 184 RS485/RS422 190 AS-Interface 191 Data Highway 194 Interbus 195 Genius 197 CC-Link 198 FOUNDATION Fieldbus 200 Sensor & Actuator Wiring
Industrial circular connectors
Industrial circular connectors M 16 M 58 010 CONINVERS - M16 to M58 circular connectors for industrial applications CONINVERS GmbH, an independent company, is the specialist for M16 to M58 circular connectors
EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.
EcoFlex Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoFlex cable is Alpha Wire s newest innovation in control cabling. A true engineering breakthrough, EcoFlex
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
Model CS 64 Mini-DIN Cable and Adaptor
Model CS 64 Mini-DIN Cable and Adaptor Page 1 of 9 Features Hi-Pro and NOAHlink compatible cable & Mini-DIN CS 64 Clip Module / NOAHlink Adaptor #1 Integrated Clip Module - Mini-DIN Cable Integrated NOAHlink
5800 Temperature Sensor Cable Assembly
5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the
Ceiling Fan Installation Instructions
Ceiling Fan Installation Instructions 1525..series OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Total fan wieght with light kit 1-1525-CUL-English INSTALLATION CH-545 Safety Tips WARNING: TO REDUCE
01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS
. HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or
WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS
CONDUCTORS Conductors are needed to complete the path for electrical current to flow from the power source to the working devices and back to the power source. Special wiring is needed for battery cables
EXCELLENCE. LAPP SYSTEMS CAPABILITIES DESIGN AND FABRICATION OF POPULATED CABLE TRACK FULL ENGINEERING DESIGN AND DOCUMENTATION INCLUDING CAD DRAWINGS
EXPECT EXCELLENCE. With a heritage dating back to 1996, Lapp Systems USA was established with the merger of OLFLEX & Contact Electronics Systems groups. Today, with over 15 years of combined experience,
LVDS Technology Solves Typical EMI Problems Associated with Cell Phone Cameras and Displays
AN-5059 Fairchild Semiconductor Application Note May 2005 Revised May 2005 LVDS Technology Solves Typical EMI Problems Associated with Cell Phone Cameras and Displays Differential technologies such as
LOW LOSS CABLE PAG. 1
LOW LOSS CABLE PAG. 1 INTRODUCTION Following many requests we received regarding the need for low-loss custom cable assemblies, we have set up a special production of high performance coaxial cable assemblies
K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)
SureGrip TM 80PK-24 Air Temperature Probe Instruction Sheet XWWarning To avoid electrical shock, do not use this probe when voltages exceeding 24 V ac rms or 60 V dc are present. The probe tip is electronically
Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range
HONEYWELL SECURITY & CUSTOM ELECTRONICS Cable Products Honeywell's Genesis Series provides a full range of low voltage cables for security, fire, sound, voice and data, video, structured cabling and other
Custom designed cables and interconnect systems for medical applications
Custom designed cables and interconnect systems for medical applications Custom designed cables and interconnect systems for medical applications Axon Cable which is ISO13485 approved, specialises in the
MARS-ALE Application Note. RS-232 Computer Control Interface for LDG Electronics DTS-4/DTS-6 Desktop Coaxial Switches. Version 1.
MARS-ALE Application Note RS-232 Computer Control Interface for LDG Electronics DTS-4/DTS-6 Desktop Coaxial Switches Version 1.02 08 April 2006 POC for this document is AAR2EY/NJ U.S. Army MARS [email protected]
Obsessed with cable solutions.
Obsessed with cable solutions. Feel better about your cables, connectors and assemblies. At C&M Corporation, we re obsessed with cable solutions. No other cable supplier has a better understanding of the
Custom designed cables and interconnect systems. for medical applications
Custom designed cables and interconnect systems for medical applications Custom designed cables and interconnect systems for medical applications Axon Cable specialises in the design and manufacture of
Physics 3330 Experiment #2 Fall 1999. DC techniques, dividers, and bridges R 2 =(1-S)R P R 1 =SR P. R P =10kΩ 10-turn pot.
Physics 3330 Experiment #2 Fall 1999 DC techniques, dividers, and bridges Purpose You will gain a familiarity with the circuit board and work with a variety of DC techniques, including voltage dividers,
IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions
IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback
MICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
Analog Multi-Pair Snake Cable High-Flex and NEC Rated Cables
B R I L L I A N C E B R O A D C A S T C A B L E S 19.16 High-Flex and Rated Cables Especially designed for the broadcast industry, Belden s full faily ulti-pair audio Snake cables feature options and construction
Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.
1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking
6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding
circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),
Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications
Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Industrial and transportation applications require robust connections with superior
Cables. Indoor, Outdoor, HDMI, CAT, connectors. Cables, connectors and tools
Indoor, Outdoor, HDMI, CAT, connectors, connectors and tools Indoor Outdoor Fly leads HDMI CAT F -/IEC connectors F -/IEC adaptors F - terminator Connection cables Power cables and electricity articles
Network/Multimedia Cables
Network/Multimedia Cables For LAN Installation, Home/Office Use Cat. 5, 6 Ethernet Cables Multi-Mode & Single-Mode Fiber Cables KVM Cables USB 2.0 Cables 1394 (FireWire) Cables F or the benefit of one-stop
HARTING. Electronic Connectors
HARTING Electronic Connectors HARTING Electronic Connectors Global Innovative Technology The HARTING Technology Group has established a reputation for excellence and innovation with decades of experience
Cables. 1.888.KEITHLEY (U.S. only) www.keithley.com ACCESSORIES
Model Description Type TERMINATIONS LENGTH From To m ft USE WITH: 236-ILC-3 Safety Interlock Shielded twisted pair 3-pin round 3-pin round 3 10 237, 4200-SCS, 8007, 8008 237-ALG-2 Low Noise Input Triax
Subject: Glenair MIL-PRF 24758 Conduit Surface Transfer Impedance Test
Lothar O. Hoeft, Ph.D. Consultant, Electromagnetic Effects 5012 San Pedro Ct., NE Albuquerque, New Mexico 87109-2515 Phone: (505)-889-9705 E-mail: [email protected] 1 February 24, 2006 Subject: Glenair
Andersen Electric Window Opener for Andersen Awning and Roof Windows
W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of
Pin Connectors. Pin Connectors. Electrical Wiring Devices for the Entertainment Industry. Bulletin: PCL-13. Copyright 2013, Union Connector Co., Inc.
Pin Connectors Pin Connectors Electrical Wiring Devices for the Entertainment Industry Bulletin: PCL-13 Copyright 2013, Union Connector Co., Inc. 20-2P&G Plugs and Connectors 2P&G Panel Mount Devices Features
Instruction Manual. Cable Splicing. Models 4500-9, 4500-9-HDF1, 4500-9-HDF2 4500-9-SS1
Instruction Manual Cable Splicing Models 4500-9, 4500-9-HDF1, 4500-9-HDF2 4500-9-SS1 No part of this instruction manual may be reproduced, by any means, without the written consent of Geokon, Inc. The
Balancing the Electrical and Mechanical Requirements of Flexible Circuits. Mark Finstad, Applications Engineering Manager, Minco
Balancing the Electrical and Mechanical Requirements of Flexible Circuits Mark Finstad, Applications Engineering Manager, Minco Table of Contents Abstract...............................................................................................
Network Engineers Everywhere:
Network Engineers Everywhere: Relax Your Minds Not Your Standards DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Patch Cable
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE USER MANUAL October 2013 This product is designed and manufactured by: ASL Intercom BV Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:
BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors
C O M M E R C I A L N E T W O R K I N G C O P P E R 15.13 Distribution Connectors, Multiplying Connectors and Modular Jack Connectors A0393146 QCBIX1A4 Connector BIX Distribution Connector The BIX Distribution
The range of rail-mounted terminal blocks. for a perfect electrical installation.
The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal
Installation & Weatherproofing Guide for ENCOM Broadband Radios
Installation & Weatherproofing Guide for ENCOM Broadband Radios Read the following instructions before proceeding with your ENCOM Wireless Radio installation. Keep these instructions in safe location for
CONNECTORS Coax & Twisted Pair
VOICE/DATA/VIDEO CONNECTORS Coax & Twisted Pair Time Saving Innovations Professional Grade For Professionals...Since 1857 CONNECTORS Coax & Twisted Pair For more information including video, scan this
LIFE-LINE Safety Cables Continuous Bending Hi-Flex Electrical Cables to Guarantee Safe Cable & Hose Carrier Systems
LIFE-LINE Safety Cables Continuous Bending Hi-Flex Electrical Cables to Guarantee Safe Cable & Hose Carrier Systems Cost-Effective Safe Reliable: LIFE-LINE Cable Carrier Systems Designed by the Experts
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially
Serial Data Grade Cables
VGA INPUT MONITOR OUT VGA INPUT MONITOR OUT 3.5mm STEREO MINI 3.5mm STEREO MINI L R Audio L R Audio AUDIO INPUTS + - + - AUDIO INPUTS + - + - AMPLIFIED OUTPUT 4/8 ohm COM 70V 100V AMPLIFIED OUTPUT 4/8
How to Choose the Right Cable Category
How to Choose the Right Cable Category Why do I need a different category of cable? Not too long ago, when local area networks were being designed, each work area outlet typically consisted of one Category
rigel 288 Electrical Medical Safety Analyser Key Features Applications
rigel 288 Electrical Medical Safety Analyser Key Features Versatile Test in Accordance with the leakage requirements of IEC/EN 60601-1, AAMI and NFPA, IEC 62353 (VDE 0751-1) using separate IEC 60601 and
Cable management for rack-mounted systems
Cable management for rack-mounted systems technology brief, 2 nd edition Abstract... 2 Introduction... 2 Cable routing guidelines... 3 Separation of power and data cables... 3 Retention of excess cable...
EH-20 20m antenna. By VE3RGW
EH-20 20m antenna By VE3RGW Equivalent circuit of EH-20 (prototype 2A) antenna system. Upper cylinder Lower cylinder Ground Counter pose Phasing coil Impedance transformer and tune circuit Tune coil Feed
Back-Up Camera Installation Guide
Hz Hz In This Guide: Back-up camera installation requires connecting power wiring to the existing reverse lighting circuit and adding a chassis ground, as well as routing a video signal cable to the front
Structured Cabling, Earthing & Equipotential Bonding
White Paper Information and Communication Technology Structured Cabling, Earthing & Equipotential Bonding English Rev. 1.0.1 / 2012-06-01 1 Abstract All Dallmeier network products (PoE cameras, recorders,
Amphenol. High Speed Solutions CABLE ASSEMBLIES
Amphenol High Speed Solutions CABLE ASSEMBLIES amphenol aerospace located in sidney, ny 1 One of the largest manufacturers of interconnect products in the world. WE design manufacture market INTERCONNECT
Screened cable and data cable segregation
December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;
10/100BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 100 Mbps Fast Ethernet. Features. Application
Features Compliant with IEEE 802.3u standard Link distance at 100Mbps: up to 100m per IEEE802.3 EEPROM with serial ID functionality Detailed product information in EEPROM Industry standard small form pluggable
SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings
*** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not
DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
Contact Hueson Corporation for additional information or details. http://www.huesonwire.com 38 Sutton Street Northbridge, MA 01534 508-234-6372
Hueson Corporation of Northbridge MA, a specialty wire and cable manufacturer has recently introduced a solution to a long term industry challenge in the Trailer Cable Industry. Their solution involves
Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection
Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification
Universal MATE-N-LOK Connectors
Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00
Hyperlinks are Inactive
Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)
Standards Affecting a Premise T-1 Installation
Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity
Understanding Shielded Cable
Understanding Shielded Cable Industrial applications such as the factory floor are typically electrically noisy environments. Electrical noise, either radiated or conducted as electromagnetic interference
AUDIO CABLES. Cinch Cables... 84 Various Audio Cables... 86 Audio Cables... 87
AUDIO Cinch Cables... 84 Various Audio Cables... 86 Audio Cables... 87 Cinch Cables Computer Power RCA connection cable, mono RCA plug RCA plug Plug color: white 109914 / AK-AV 200 1,5 m 109921 / AK-AV
Trunk Cables. www.teletronik.com
Trunk Cables www.teletronik.com Brief Introduction Teletronik TC series coaxial cable was developed to meet the increasing demand of tomorrow's broadband networks. TC series cable has the highest reliability
Technical Note Series
Technical Note Series SKIN CONDUCTANCE SENSOR (SA9309M) S TN0 0 0 8-0 0 S k i n C o n d u c t a n c e S e n s o r Page 2 IMPORTANT OPERATION INFORMATION WARNING Type BF Equipment Internally powered equipment
PARAMOUNT ME MOUNTING AND WIRING KITS FOR USE WITH THE TCF-S / IFW / Pyxis Revised 3/18/2008
PARAMOUNT ME MOUNTING AND WIRING KITS FOR USE WITH THE TCF-S / IFW / Pyxis Revised 3/18/2008 Optec Stock #17496 for TCF-S OR IFW AND PYXIS Optec Stock #17497 for TCF-S OR IFW Optec Stock #17498 for PYXIS
Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement
Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement This work instruction describes the methods and means for which to remove and reinstall optional scanner cable configurations
UNBALANCED OUTPUT TO BALANCED INPUT WIRING METHODS
MEASURING UNBALANCED DEVICES USING THE SIM-0 AUDIO ANALYZER audio devices and/or sources must sometimes be used within a sound reinforcement system, and integrated with balanced inputs and outputs. These
INCORPORATING WEIGHT-SAVING TECHNOLOGY IN AEROSPACE APPLICATIONS: AT WHAT RISK?
INCORPORATING WEIGHT-SAVING TECHNOLOGY IN AEROSPACE APPLICATIONS: AT WHAT RISK? John Kuster, Senior Product Manager Harnessing Products TE Connectivity Aerospace, Defense & Marine Republished by Aerospace
Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.
Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s
COMPACT DATA FAST AND SIMPLE DATA CABLE TRUNKING. www.rehau.co.uk. Building Solutions Automotive Industry
FAST AND SIMPLE DATA CABLE TRUNKING www.rehau.co.uk Building Solutions Automotive Industry UNOBTRUSIVE GOOD LOOKS FOR THE VERY LATEST DATA CATEGORY CABLING PART OF THE REHAU DATA CABLE MANAGEMENT RANGE
CABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
Ethernet Patch Cord Wiring
Ethernet Patch Cord Wiring C ONTENTS Ethernet Patch Cords & RJ-45 Connectors... 2 Ethernet Patch Cords and UTP Cabling... 3 What s all the twisting about?... 4 Ethernet Applications... 5 568A & 568B Wiring
Standard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
DIOCESE OF LINCOLN GUIDELINES
DIOCESE OF LINCOLN GUIDELINES FOR ELECTRICAL INSTALLATIONS INSIDE CHURCHES Diocesan Advisory Committee for the Care of Churches Revised March 2006 Electrical Installations inside Churches As with all