Flow. Hach Sigma 950 Series Permanent/Portable. Open Channel Flow Meters. Features and Benefits DATA SHEET. Versatility and Customization
|
|
|
- Lynn Norton
- 10 years ago
- Views:
Transcription
1 DATA SHEET Hach Sigma 950 Series Permanent/Portable Open Channel Flow Meters Flow Hach Sigma 950 Series Permanent/Portable Open Channel Flow Meters provide portable and/or permanent single-channel monitoring plus water quality testing, process control interface, and digital display. Both models offer maximum flexibility for multiple applications including surcharge or reversed flow conditions, weirs and flumes, and small-to-large channels.up to three different level sensor technologies and velocity in one meter. Features and Benefits Versatility and Customization For applications that require more than a flow monitor, use the Hach Sigma 950 Open Channel Flow Meter with rainfall, ph, temperature, ORP, dissolved oxygen, and/or conductivity monitoring capability. Three standard level measurement technologies are available ultrasonic, submerged, or bubbler. The Sigma 950 AV Optiflo flow meter has the additional option of Doppler velocity measurement. All Sigma 950 flow meters also have analog inputs for logging data from other instruments, such as total suspended solids monitors. Sampler Pacing and Equipment Control Use Hach Sigma 950 flow meters to control samplers, pumps, or other equipment based on monitored flow or selected parameter(s) based on high/low set points with built-in relay outputs. Sampler pacing provides the ability to document overflow problems. Easy to Use Interface The large LCD graphics quickly displays information on-site (available in 10 languages) without the inconvenience of paper charts. The built-in keypad makes using laptops in the field optional. A single keystroke can provide an instantaneous data summary and review of all program settings. Communications and Data Storage Options Industry standard SCADA MODBUS ASCII protocol is included in all Sigma 950 flow meters ma outputs are available for flexible integration with a SCADA system. Remote communications is available via modem or RS-232 connection. Store 18,000 data points in memory (expandable to 116,000 data points). Superior Submersible Area Velocity Sensor for Open Channel Applications The Hach Sigma 950 AV Optiflo flow meter provides Doppler velocity monitoring that uses advanced ultrasonic, one-mhz Doppler technology for flow measurements. This technology avoids signal dropouts and ensures high levels of accuracy in low-flow, full-pipe, or reversed-flow conditions. Installation is fast and single point atmospheric calibration is easy. Applications Hach Sigma 950 Permanent/Portable Open Channel Flow Meter Long term or permanent flow studies Sanitary sewer evaluation studies CSO studies and monitoring NPDES stormwater compliance Industrial compliance monitoring Hach Sigma 950 AV Optiflo Permanent/Portable Open Channel Flow Meter Applications involving frequent moving of meter to different site conditions WW IW C DW = drinking water WW = wastewater municipal PW = pure water / power IW = industrial water E = environmental C = collections FB = food and beverage
2 2 Specifications* Flow Meter Specifications Units of Measurement Flow: gps, gpm, gph, lps, lpm, lph, mgd, afd, cfs, cfm, cfh, cfd, m 3 s, m 3 m, m 3 h, m 3 d Totalized Flow: L, m 3, ft. 3, gal., acre-ft. Primary Devices Flumes: Parshall, Palmer Bowlus, Leopold-Lagco, H, HL, HS, trapezoidal Weirs: V-notch (15 to 120 ) contracted/non-contracted rectangular, Thelmar, compound Cipolletti Manning Equation: Round, U and rectangular trapezoidal channels Flow Nozzles: Kennison, parabolic, California pipe Head vs. Flow: Custom programmable curve (up to 99 points) -10 to 65.5 C (14 to 150 F) Storage Temperature -40 to 80 C (-40 to 176 F) Time-Based ±1 second per day (one level and one velocity, data download once per week, at 10 C (50 F), also affected by site conditions) Totalizers 8-digit resettable and 8-digit nonresettable LCD software totalizer Optional 6-digit non-resettable mechanical totalizer Graphics Display Back lit LCD Auto-off when not in use SCII Mode: 8 line x 40 character Graphics Mode: 60 x 240 dot : 3.8 x 12.7 cm (1.5 x 5 in.) Displays: level vs. time, flow vs. time Optional Displays: rainfall, ph, ORP, temperature, DO, conductivity vs. time, sampler events, and alarm events Keypad 21 position sealed membrane switch with blinking green LED to indicate power on Four soft keys, functions defined by display Data Storage Capacity: Up to 512k bytes (402 days of level, velocity, and rainfall readings at 15 minute inter-vals plus 300 events) Monitoring Intervals: 1, 2, 3, 5, 15, 30 or 60-minute intervals Program Memory Non-volatile programmable flash, can be updated via RS-232 port Sampler Output 12 to 17 Vdc pulse, 100 ma maximum at 500 ms duration Communications RS-232: up to 19,200 baud SCADA MODBUS communication protocol via RS-232 or optional modem Modem (optional):14,400 baud Cellular Communications (optional): 14,400 bps, MNP 10-EC Cellular Protocol Pager Alarms Enclosure ABS, UV resistant Enclosure Rating NEMA 4X,6 Power Source 12 Vdc Power Options 6 amp-hr. gel electrolyte rechargeable battery 4 amp-hr. Ni-Cad rechargeable battery Lantern battery case with two 6-Volt lantern batteries 115 Vac, 230 Vac, or 100 Vac power converter with battery charger 34.3 x 25.4 x 24.1 cm (13.5 x 10.0 x 9.5 in.) Weight 6.8 kg (15 lbs.) with batteries Sensor Specifications 950 BUBBLER SENSOR to 3.6 m (0.01 to ft.) 0.01 to ft. ±0.011 ft. (±0.003 m) (linearity and hysteresis at 22 C (72 F)) Ambient -18 to 63 C (0 to 145 F) Compensated Temperature 0 to 59 C (32 to 138 F) ± ft./ F (maximum error within compensated temperature range per degree of change) Air Intakes Bubble source and reference port desiccant protected. Fittings provided for remote intakes. Filter 10 micron on bubble source intake Line Purge Bubble line is high pressure purged at programmed intervals, or in manual mode on demand Line Size 0.32 cm (1/8 in.) ID standard 950 ULTRASONIC SENSOR 50 khz Ultrasonic Transducer 38.1 cm to 9.1 m (15 in. to 30 ft.) sensor to liquid 1 to 10 ft. ±0.01 ft. (±0.003 m) (at 22 C (72 F), still air, 40 to 70% relative humidity) Span 50 khz, 0 to 29 ft. Ambient ± ft./f (maximum error within compensated temperature range per degree of change) ft. PVC housing Buna-N acoustic window 4-conductor with integral stainless steel support Length: 7.6 m (25 ft.) standard Continured on next page.
3 3 Specifications continued Crystal Specification 50 khz, 11.5 included beam angle 9.5 x 7 cm (3.75 x 2.75 in.) Weight 0.7 kg (1.5 lbs.) 75 khz Ultrasonic Transducer 23 cm to 3.3 m (14 in. to 1 ft.) sensor to liquid 1 to 10 ft. ±0.01 ft. (±0.003 m) (at 22 C (72 F), still air, 40 to 70% relative humidity) Span 0 to 15 ft. Ambient ± ft./f (maximum error within compensated temperature range per degree of change) ft. PVC housing Buna-N acoustic window 4-conductor with integral stainless steel support Length: 7.6 m (25 ft.) standard Crystal Specification 5 beam angle with horn 12.7 x 5.7 cm (5.0 x 2.25 in.) Weight 0.7 kg (1.5 lbs.) 75 KHZ ULTRASONIC LEVEL SENSOR (IN-PIPE) 0 to 3.35 m (0 to 11 ft.) to 4.57 m ±.003 m (0.125 to 15 ft. ±0.01 ft.) (at 22 C (72 F), still air, 40 to 70% relative humidity) Span to 4.57 m (0.125 to 15 ft.) Ambient ± m/ C (± ft./f ) maximum error within compensated temperature range per degree of change cm ( in.) Stainless steel housing Buna-N acoustic window 4-conductor Length: 7.6 m (25 ft.) standard; 305 m (1000 ft.) using RS-485 two wire remote sensor option Crystal Specification 75 khz, 7 included beam angle 3.81 x 30 cm (2.0 x 12 in.) 950 SUBMERGED PRESSURE SENSOR Choice of: 2.5 psi: 0.01 to 1.75 m (0.04 to 5.75 ft.) 5.0 psi: 0.01 to 3.58 m (0.04 to ft.) 10.0 psi: 0.01 to 7.0 m (0.04 to 23 ft.) ±0.1% full scale (non-linearity and hysteresis) Transducer Type: Differential piezo resistive with balanced bridge Orientation: Inverted Maximum Allowable Level 6x over pressure 0 to 71 C (32 to 160 F) Compensated Temperature 0 to 36 C (32 to 96 F) : 2.5 psi: 0.04 to 5.75 ft. ±.006 ft./f 5.0 psi: 0.04 to ft. ±.0012 ft./f 10.0 psi: 0.04 to 23 ft. ±.0024 ft./f (Maximum error within compensated temperature range per degree of change) Air Intake Atmospheric pressure reference is desiccant protected 316 stainless steel body with titanium diaphragm 4-conductor polyurethane sensor with air vent Length: 7.6 m (25 ft.) standard; 76 m (250 ft.) maximum 2.54 x 17.2 cm (1 x 6.75 in.) Probe Frontal Area: in 2 Weight 0.7 kg (1.5 lbs.) SUBMERGED DEPTH/AREA VELOCITY SENSOR Level Measurement Doppler principle/pressure transducer Standard: to 3.5 m ±0.007 m (0.018 to 11.5 ft. ±0.023 ft.) Extended: to 10.5 m ± m (0.018 to 34.6 ft. ±0.07 ft.) (Non-linearity and hysteresis) Maximum Allowable Level 3x over pressure 0 to 71 C (32 to 160 F) Compensated Temperature 0 to 30 C (32 to 86 F) to 3.5 m ± m/ C (0.018 to 11.5 ft. ±0.004 ft./ F) to 10.5 m ±0.006 m/ C (0.018 to 34.6 ft, ±0.012 ft./ F) (Maximum error within compensated temperature range per degree of change) Velocity Induced Error on Depth (patent pending) 0 to 3.05 m/s (0 to 10 ft./sec.) = 0.085% of reading Air Intake Atmospheric pressure reference is desiccant protected Continured on next page.
4 4 Specifications continued Velocity Measurement Doppler ultrasonic Transducer Type Twin 1 MHz piezoelectric crystals to 6.10 m/s (-5 to 20 fps) Zero Stability < m/s (0.05 fps) ±2% of reading Depth for Velocity 2 cm (0.8 in.) minimum, typical General Polymer body with stainless steel diaphragm Urethane sensor with air vent Length: 7.6 m (25 ft.) standard; 76 m (250 ft.) maximum 2 x 3.8 x 12.7 cm (0.8 x 1.5 x 5 in.) BUBBLER LEVEL/AREA VELOCITY SENSOR Level Measurement Doppler principle/pressure transducer to 3.6 m (0.01 to ft.) 0.01 to ft. ±0.011 ft. (0.033 m) (linearity and hysteresis at 22 C (72 F)) Ambient -18 to 63 C (0 to 145 F) Compensated Temperature 0 to 59 C (32 to 136 F) ± ft./ F (maximum error within compensated temperature range per degree of change) Air Intakes Bubble source and reference port desiccant protected. Fittings provided for remote intakes. Filters 10 micron on bubble source intake Line Purge Bubble line is high pressure purged at programmed intervals, or in manual mode on demand Velocity Measurement Doppler ultrasonic Transducer Type Twin 1 MHz piezoelectric crystals to 6.10 m/s (-5 to 20 fps) Zero Stability < m/s (0.05 fps) ±2% of reading Depth for Velocity 2 cm (0.8 in.) minimum, typical 1.12 x 3.81 x 6.86 cm (0.44 x 1.5 x 2.7 in.) VELOCITY SENSOR Doppler principle ±2% of reading Zero Stability ±1.52 cm (±0.05 fps) Nose Angle 20 from horizontal Length: 7.6 m (25 ft.) standard; custom lengths to 76 m (250 ft.) Diameter: 0.57 cm (0.225 in.) s Sensor: Polymer : Urethane Mounting Hardware: Stainless steel 1.5 x 3.8 x 9.7 cm (0.5 x 1.5 x 3.7 in.) Factory Installed Options ph-temperature/orp METER Control/Logging Field selectable to log ph-temperature or ORP independent of flow or in conjunction with flow; also controls sample collection in response to value exceeding low/high set points ph/temperature Sensor Temperature compensated; impact resistant ABS plastic body; combination electrode with porous Teflon junction 2 to 12 ph within specifications; 0 to 14 ph maximum range -18 to 80 C (0 to 176 F) Recording Intervals 1, 2, 3, 5, 6, 10, 12, 15, 30, and 60 minutes Probe Pre-Amplifier/Junction Box NEMA 4X with labeled terminal strip 1.9 x 15.2 cm (0.75 x 6 in.) with 1.9-cm (0.75-in.) MPT end INTEGRAL DISSOLVED OXYGEN/TEMPERATURE METER Control/Logging Field selectable to log dissolved oxygen independent of flow or in conjunction with flow; also controls sample collection in response to value exceeding low/high set points Measurement Polargraphic Sensor Temperature compensated; impact resistant polypropylene body Continured on next page.
5 5 Specifications continued 0 to 20 mg/l dissolved oxygen 0.01 mg/l ±0.2 mg/l 0 to 50 C (32 to 122 F) Recording Intervals 1, 2, 3, 5, 6, 10, 12, 15, 20, 30, and 60 minutes 1.65 x 12.7 cm (0.65 x 5 in.) with 1.9-cm (0.75-in.) MPT end INTEGRAL CONDUCTIVITY/TEMPERATURE METER Control/Logging Field selectable to log conductivity independent of flow or in conjunction with flow, also controls sample collection in response to value exceeding low/high set points Sensor Temperature compensated; impact resistant polypropylene body 0 to 20 ms/cm 0.01 ms/cm or 0.01 µs/cm (user selectable) ±1% of reading ms/cm 0 to 50 C (32 to 122 F) Recording Intervals 1, 2, 3, 5, 6, 10, 12, 15, 20, 30, and 60 minutes 1.70 x 12.7 cm (0.67 x 5 in.) with1.9-cm (0.75-in.) MPT end RAIN GAUGE INPUT For use with Hach Tipping Bucket Rain Gauge. Flow Meter records rainfall data in 0.01-in. increments. Flow measurement can be initiated based upon field selectable rate of rain. ANALOG INPUT DATA-LOGGING CHANNELS Up to seven additional data-logging channels record data from external sources. Field assignable channel name(s) and units. -4 to +4 Vdc; ±0.5% full scale voltage accuracy 0 to 20 ma; ±0.2% full scale 4-20 ma accuracy with 200 ohm impedance 4 TO 20 MA OUTPUTS Up to two integral field assignable outputs Optically isolated Up to 600 ohm load per output 0.1 % FS error ALARM RELAYS Up to four integral alarm relays 10 amp, Form C User assignable to any internal or external data channel MECHANICAL TOTALIZER 6-digit non-resettable mechanical totalizer Selectable units: gal., liters, ft. 3, m 3, acre-ft. MODEM 14,400 baud rate CRC auto to check sum FCC approved Cellular compatible EXPANDED MEMORY Increase memory from 18,432 data points to 116,736 data points AC POWER BACKUP Provides power in the event of an AC power failure Internal trickle charger maintains 6 amp-hour battery Teflon is a registered trademark of E.I. Dupont de Nemours Inc. *Specifications subject to change without notice.
6 6 Engineering Specifications Flow Meter 1. The flow meter shall operate on 12 Vdc, which is supplied by a battery or 115 Vac power converters. 2. All electrical components shall be enclosed in a NEMA 4X- 6 enclosure. The enclosure shall have a continuous hinged front cover to protect the display and keypad and shall maintain NEMA 4X,6 with the cover open. 3. The enclosure shall contain desiccant and a front panel humidity indicator. 4. Current data shall be displayed on the flow meter front panel by means of an external push button on the enclosure. The meter shall not require opening of a cover to see current status. 5. The meter shall have an 8 line x 40-character backlit liquid crystal graphics display. In addition to indicating all programming steps and current status such as level, velocity and flow rate, the display shall show all logged data in field selectable tabular and graphics (x-y plot) formats. 6. All program entries shall be entered via a sealed front panel keypad, and indicated on the front panel display. The keypad and display shall meet NEMA 4X-6 standards. 7. A personal computer or any other external means shall not be required to program the flow meter or integral logger or access data. 8. Flow meter programming/measurements: a. The flow meters shall be field programmable for primary devices including: i. Weirs: V-notch weirs (any angle from 22.5 to 120 degrees, compound V-notch/rectangular weirs, contracted and non-contracted rectangular weirs, trapezoidal weirs, and Thel-Mar weirs. ii. Flumes: Parshall (1 to 144 inch), Palmer Bowlus (4 to 72 inch), trapezoidal (60 degree small, large, and extra large, 45 degree 2 and 12 inch), H. HL, and HS type flumes, and Leopold-Lagco (4 to 72 inch). iii. Nozzle: California pipe method; Manning equation for round, U-channel, rectangular, and trapezoidal cross sections; power curve equation. iv. Head vs. flow tables: Two tables of up to 99 (head, flow) points per table (tables may be stored in flow meter s memory and retrieved as required). b. Field selectable units of measurement shall include: i. Level: Inches, feet, centimeters, and meters. ii. Flow rate: GPS, GPM, GPH, MGD, AFD, LPS, LPM, LPH, CFS, CFM, CFH, CFD, CMS, CMM, CMH, CMD. iii. Total flow: Gallons, cubic feet, acre-feet, liters, and cubic meters. 9. Flow totalizing: a. The flow meter shall have two software totalizers, one resettable and the other resettable. b. (Optional) The meter shall include a 6-digit nonresettable electro-mechanical totalizer, protected to meet NEMA 4X, 6 standards. 10. Sampler pacing: a. The flow meter shall have a 12 Vdc pulse output for pacing an automatic liquid sampler in proportion to flow, with field selectable flow volume between pulses. b. The meter shall be capable of initiating a sampler on level, flow rate, and flow rate of change. 11. Integral metering devices (optional): a. The meter shall be equipped with an integral phtemperature/orp meter. The ph meter shall have a range of 0 to 14 ph with a ±1% resolution over an operating range of 0 to 176 degrees F. b. The meter shall be equipped with an integral temperature meter. The temperature meter shall have an operating range of 0 to 176 degrees F. The meter shall include a platinum RTD probe in a stainless steel body with 25-foot. c. The meter shall be equipped with an integral dissolved oxygen (DO) meter. The DO meter shall have a range of 0 to 20 mg/l (DO) with 0.01 mg/l resolution and 3% (1 ppm) accuracy. d. The meter shall be equipped with an integral conductivity meter. The conductivity meter shall have a range of 0 to 20 ms/cm with 0.01 ms/cm resolution and 2% (0.01ms) of reading accuracy. e. The meter shall be equipped with a rain gauge input. The sampler shall accept contact closure inputs from an external rain gauge. f. The meter shall be equipped with seven external analog inputs. The first four channels shall be capable of logging a 4-20 ma current input, and the remaining three channels shall be set up to log -4.5 to +4.5 Vdc voltage input. 12.The flow meter and sensor shall be the Sigma Model 950 Permanent/Portable Open Channel Flow Meter OR Sigma Model 950 AV Optiflo Permanent/Portable Open Channel Flow Meter manufactured by Hach Company.
7 7 Placement of Hach Sigma 950 Series Permanent/Portable Open Channel Flow Meters depends on the suitability of the monitoring site. Select sites that have normalized flow and minimal turbulence. Turbulence can make it difficult to detect an average velocity in the flow stream. Obstructions, vertical drops, pipe bends, and elbows can create turbulence and affect the accuracy of measurements. Mounting options for Sigma 950 flow meters include wall mounting, suspension harness installation, or manhole rung hanger.
8 8 Ordering Information Flow Meter Bundles Bubbler Flow Meter; includes 25 ft. tubing Submerged Pressure Flow Meter; includes 25 ft. sensor khz Down-look Ultrasonic Flow Meter; includes 25 ft. sensor khz In-Pipe Ultrasonic Flow Meter; includes 25 ft. sensor Bubbler AV Flow Meter; includes 25 ft. of sensor Submerged AV Flow Meter; includes 25 ft. of sensor k Hz Ultrasonic AV Flow Meter with In Pipe Ultrasonic and Velocity Sensors Integral Water Quality Options and Sensors 2684 Factory Installed Integral ph- Temp/ORP Sensor; includes pre-amp interface 3328 ph-temperature Sensor (grounded); includes 25 ft ORP Sensor; includes 25 ft Factory installed DO and Conductivity Sensor; includes pre-amp interface 3228 Factory installed DO and EC Option with three 4-20mA Input Data Logging, includes pre-amp interface 3216 DO Probe Kit; includes 25 ft Conductivity Probe Kit; includes 25 ft DO Probe only; includes 25 ft Conductivity Probe only; includes 25 ft. Communication and Control Interfaces 2676 First 4-20 ma Output; includes 25 ft Second 4-20 ma Output 2691 First Set Two (2) Alarm Relays with settable trip points 2707 Second Set Two (2) Alarm Relays with settable trip points 4578 Modem; 14,400 baud (domestic lines only) Sensor Mounting Hardware 1361 Spring Ring for 6-in. diameter pipe 1362 Spring Ring for 8-in. diameter pipe 1363 Spring Ring for 10-in. diameter pipe 1364 Spring Ring for 12-in. diameter pipe 3263 Sensor Mounting Clip; for 88000, wafer velocity, and bubbler level velocity sensors 3868 Portable Bracket; for in-pipe ultrasonic sensor mounting clip 3875 Permanent In-Pipe Ultrasonic Sensor Mounting Bracket 3305 Velocity Sensor Mounting Plate 9574 Insertion Tool; for non-confined space entry 2974 Permanent Wall Mount Bracket; for down-looking ultrasonic sensor 2904 Floor or Wall Adjustable Mounting Bracket; for downlooking ultrasonic sensor 9538 Tripod Mounting Bracket; for down-looking ultrasonic sensor 2883 Straightener; for downlooking ultrasonic sensor 3183 Grip; for down-looking ultrasonic sensor s and Interfaces 1727 Sampler or Flow Meter to PC 3358 RS232 Extension Accessories Silicon Oil; dual 50-ml pack (refills 100 sensors) Silicon Oil Refill Kit; includes dispensing tool and oil packs Oil-Filled Sub-AV Sensor Kit Retrofit Kit (converts non oilfilled to oil-filled); includes Silicon Oil Refill Kit At Hach, it s about learning from our customers and providing the right answers. It s more than ensuring the quality of water it s about ensuring the quality of life. When it comes to the things that touch our lives... Keep it pure. Make it simple. Be right. For current price information, technical support, and ordering assistance, contact the Hach office or distributor serving your area. In the United States, contact: HACH COMPANY World Headquarters P.O. Box 389 Loveland, Colorado U.S.A. Telephone: Fax: [email protected] U.S. exporters and customers in Canada, Latin America, sub-saharan Africa, Asia, and Australia/New Zealand, contact: HACH COMPANY World Headquarters P.O. Box 389 Loveland, Colorado U.S.A. Telephone: Fax: [email protected] In Europe, the Middle East, and Mediterranean Africa, contact: HACH LANGE GmbH Willstätterstraße 11 D Düsseldorf GERMANY Tel: +49 (0) Fax: +49 (0) [email protected] Lit. No E64 Printed in U.S.A. Hach Company, All rights reserved. In the interest of improving and updating its equipment, Hach Company reserves the right to alter specifications to equipment at any time.
DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.
and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the
Galvanic Parts Per Million Dissolved Oxygen Systems
Galvanic Parts Per Million Dissolved Oxygen Systems Model 900 Portable s Model 9100 Model 9200 Model 9300 The Royce line of PPM level dissolved oxygen (DO) analyzers is the largest, most varied line in
Interface Level And Point Level Analyzers & Sensors
Interface Level And Point Level Analyzers & Sensors Model 2511 Analyzer Model 2505 System Model 2120 System Royce now offers a complete line of Interface Level and Point Level Analyzers that make it possible
Steven R. McManus Environmental Product Support Teledyne Isco
Steven R. McManus Environmental Product Support Teledyne Isco Flow Measurement Applications and Technologies. Methods of flow measurement Technologies of flow measurement Flow Rate Applications Channel
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Open Channel & Partially Filled Pipe Ultrasonic Flow Meters
Open Channel & Partially Filled Pipe Ultrasonic Flow Meters DYNAMETERS series DMDF-OP has three types as below: DMDF-OP-A for partially filled pipe application; DMDF-OP-B for partially filled pipe, channel
WEATHER STATION FOR SOLAR FARM MONITORING
WEATHER STATION FOR SOLAR FARM MONITORING SOLAR FARM MONITORING SYSTEM: Measures global, horizontal, & background irradiance. Measures wind speed, wind direction, ambient temperature, and relative humidity.
Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS
EPP - 1 DECRIPTION The odel 575 is used in general water/wastewater applications. The transmitter is offered in a standard non-clogging snub nose end, flush diaphragm or protected flush diaphragm with
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
O C M III. Open Channel Flow Monitor
O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this
OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system
Sistema autolimpiable Dissolved Oxygen Autoclean system Applications: - water treatment - activated sludge - de-nitrification - fish pond Install & forget For special applications, the D.O monitor can
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
GLS 3700 6712. Sampler Selection Guide
Glacier 5800 6712FR Avalanche GLS 3700 6712 Sampler Selection Guide Advanced Automated Sampler Products From Teledyne Isco With more than four decades of industry leadership, Teledyne Isco continues to
Mobrey open channel flow measurement systems
Technical specification sheet IP2039 October 2008 Level Mobrey open channel flow measurement systems Comprising: MCU Flow log datalogging control unit MSP900** Ultrasonic level transmitter Mobrey MCU/MSP
LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER
LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER System for flow measurement, data acquisition and transmission for wastewater with long battery life With Long Life Battery Open Channel Flow Meter
THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
Flow Measurement Options for Pipeline and Open Channel Flow
Flow Measurement Options for Pipeline and Open Channel Flow October 2013 Presented by Molly Skorpik - 2013 Montana Association of Dam and Canal Systems Conference Irrigation Training and Research Center
Sample specifications for an effective Flow Monitoring Services RFP
Sample specifications for an effective Flow Monitoring Services RFP Red copy indicates areas requiring specific input Each specification is numbered for quick identification 1. Project Specifications 1.1.
FLOW HUNTER II & XDS 03
FLOW HUNTER II & XDS 03 Open Channel Flow Meter Instruction Manual November 2012 Edition ECHO Process Instrumentation, Inc. PO Box 800, Shalimar, FL 32579 USA Phone: 850-609-1300, Fax: 850-651-4777 Email:
Open channel & partially filled pipe Ultrasonic flow meters
Open channel & partially filled pipe Ultrasonic flow meters SUITABLE FOR PARTIALLY FILLED PIPES AND OPEN CHANNEL FAMOUS PROFESIONAL ULTRASONIC FLOWMETERS MANUFACTURER, ADVANCED TECHNOLOGY, SERIES PARTIALLY
Nardalert S3 Non-Ionizing Radiation Monitor
Patent Pending Non-Ionizing Radiation Monitor Field Replaceable Sensor Modules Color LCD Display Multi-Color Alarm LED s USB Interface for Data and Charging Interchangeable Lanyard or Belt Clips Comprehensive
ORBISPHERE M1100: CUSTOMER SUCCESS STORY - CARLSBERG
PRACTICE REPORT PROCESS ANALYSIS OXYGEN MEASUREMENT BREWING ORBISPHERE M1100 CUSTOMER SUCCESS STORY - CARLSBERG Authors: Stephen Bell, Global Product Line Manager, HACH LANGE S.A. Frank Dunand. Senior
PORTABLE FLOW METER KITS TDS-100H
Transit Time Flow Meters TT-TDS-100H-HS ECEFast offers amazing prices on Transit Time Flow Meter portable kits. We are buying from the manufacturer who supplies 60% of the Chinese market and the majority
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
For Multi-Parameter Meters see mvx
BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
Series DFMT Digital Paddlewheel Flowmeter
Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
USB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter
www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding
WIRELESS INSTRUMENTATION TECHNOLOGY
BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904
920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown
Self-Regulating 920 Series Dual-point heat-tracing control system Power-Limiting Mineral Insulated 920*E4FWL*SIS302*SS3102 shown Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based,
General Purpose ph/orp Sensors
General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 / Rev. F December 2014 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided
Signet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount Multiple sensor types supported with one instrument Dial-type digital bar graph NEW! View ph/orp sensor
2.24. Pump Controller 704. Data Sheet
Pump Controller 704 2.24 There are several reasons to choose an MJK pump controller. Pump controller 704, as described in this data sheet, was introduced in 1989. It has been updated several times with
PRODUCT PROFILE FEATURES
PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.
Dual-line FLOW rate/totalizers Pr ovu PD6200 Analog Input ProVu Se r i e s Pr ovu PD6300 Pulse Input Analog Inputs 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs Isolated 24 VDC @ 200 ma Transmitter
User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510
User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor
CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5
Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]
Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64 [113.89]
Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
Electromagnetic Flow Meter
Electromagnetic Flow Meter Description The EL 2200 series of electromagnetic sensors represent the state of the art for the accurate measurement for water cycle and process applications. Flow meters are
Smart Electromagnetic Flowmeter Open channel Flowmeter Detector
Magne3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIE The Magne3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter mainly used for flow
Resolution selectable from 0.01 and 0.001 ph. Range -2.000 16.000 ph. Accuracy ± 0.002 ph
ph EC DO ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand manual log on stability Interval logging Temperature readout ( C or
Hand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
SDX Submersible Depth Transmitter User Manual
SDX Submersible Depth Transmitter User Manual January 2011 USER INFORMATION Stevens makes no warranty as to the information furnished in these instructions and the reader assumes all risk in the use thereof.
DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS
DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS 1. Description and Phone Number Dialing: The dialer shall be a solid state component capable of dialing up to 16 telephone numbers, each up to 60 digits
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
Wahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
CAMS. Combustion Airflow Management System. Proven solutions for a tough industry
CAMS Combustion Airflow Management System Proven solutions for a tough industry CAMS TM Combustion Airflow Management System Product Description The Air Monitor Power CAMS TM Combustion Airflow Management
Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219
Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
Understanding the Flo-Dar Flow Measuring System
Understanding the Flo-Dar Flow Measuring System Independent tests verify non-contact flowmeter is highly accurate under both open channel and surcharge conditions TM Flo-Dar is the only non-contact open
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
INTREPID Perimeter Intrusion Detection System
TM INTREPID Perimeter Intrusion Detection System Next Generation Perimeter Protection icropoint Cable combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience.
USB-500 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
Perimeter Security System
TM Perimeter Security System The Next Generation Perimeter Security System ICRONET combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience. It is a sophisticated
Mobrey open channel flow measurement systems
Specification sheet IP2039 Sept 2005 Level Mobrey open channel flow measurement systems Comprising : MCU Flow log datalogging control unit MSP900** Ultrasonic level transmitter Mobrey Measurement MCU/MSP
450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer
450 Analyzer 450 Analyzer Fast, Continuous Measurement Compliant with USP, Ch P, EP and JP USB Data Logging and Printer Output Robust Portable Design Portable, Real-time, Continuous Total Organic Carbon
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:
GE Measurement & Control Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low
Pow-R-Con Multi Function Control
37264 Pow-R-Con Multi Function Control Product Specification Product Specification 37264 Product Information DYNA Power Controls Pow-R-Con TM GENERAL The Barber-Colman Pow-R-Con TM represents an integrated
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
ENAiKOON ultrasonic fuel-level sensor
ultrasonic fuel-level sensor Product Summary The ultrasonic fuel-level sensor is the perfect solution for monitoring the fuel level and fuel consumption of trucks, boats, construction equipment, generators,
Features. Picture. Specifications
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring
SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE
Series Circuit Breaker Monitors CONSOLIDATED Electronics, Inc. MONITORING THE FUTURE Why SF Gas Density Monitors? 6 Cut Maintenance Costs Your capital investment may be recovered with the elimination of
Configuring the HydroRanger 200 to measure open channel flow. Specific parameter setting to configure the following primary measurement devices:
Flow Application Configuration AG040308 Configuring the HydroRanger 200 to measure open channel flow Objective: Specific parameter setting to configure the following primary measurement devices: exponential
Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across
Flow Pulse Unique, non-invasive clamp-on flow monitor Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across
Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since 1997. automated production systems
Alarm Systems Agri-Alert alarms have been protecting swine operations across the world since 1997. Peace of Mind The Agri-Alert alarm system constantly monitors your operation and quickly notifies you
Gas Custody Transfer Calibration
Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform
Agilent 4338B Milliohm Meter
Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
UTM10 Series Ultrasonic Transit-time Flowmeters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
Long Distance Industrial Wireless Transmitters and Receivers
Long Distance Industrial Wireless s and Receivers Up to 450 m (1500') Line of Sight Range UWXL Series U Thermocouple, RTD, Temperature, RH, ph, Process Voltage/ Current and Input Models U J, K, T, E, R,
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
Agilent 4339B/4349B High Resistance Meters
Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
HOW-TO GUIDE FOR STORMWATER MONITORING
White Paper January 2014 by Kevin Simpson HOW-TO GUIDE FOR STORMWATER MONITORING The Dos, Don ts and Must Haves! Stormwater monitoring doesn t have to be a headache for your organization. With proper site,
Solid State Timers Type F
Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application
Chapter2. Installation
Chapter2. Installation Power Supply Requirements The ULM-1000C operates from a DC supply of 20 30V and will typically draw less than 0.08A. All electronic products are susceptible to electrostatic shock,
1/2 NPTM. 29.21 mm 1.15. Nose cone fitting Ideal for clean liquids
PT-500 Submersible Liquid Level Transmitter 1.0 Hex 25.4 mm 7.0 177.8 mm Re-Usable cage fitting Ideal for dirty liquids 5.63 143 mm 5.33 136 mm 1/2 NPTM 3.5 88.9 mm 1.15 29.21 mm Nose cone fitting Ideal
Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3
Typical Applications Typical Applications Construction Transmitter Assembly Pipe & cable locator transmitter Transmitting active signals for the location of buried pipes and cables High impact ABS Weight
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
The software solution to complete your flow monitoring program
The software solution to complete your flow monitoring program Flowlink 5.1 software is the central point of your flow data management program. With this software you can: Configure Isco equipment on-site
SUMMARY of PRODUCTS. HVAC Systems Control Airflow, Space, & Building Pressurization. Accurate airflow measurement for demanding applications
SUMMARY of PRODUCTS HVAC Systems Control Airflow, Space, & Building Pressurization Accurate airflow measurement for demanding applications Airflow Measuring Stations FAN-E AIRFLOW MEASURING STATION. The
USB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.
Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com