1 UPS SYSTMS Tripp Lite UPS Systems Reliable, efficient, manageable power and battery backup Introduction ow to hoose a UPS System 2-3 UPS eature omparison 4-5 Network/Server UPS Systems LIN-INTRTIV OPRTION SmartPro Rack/Tower UPS 6-9 SmartPro Shallow-epth Rack UPS SmartPro Tower UPS ON-LIN OPRTION SmartOnline Rack/Tower UPS SmartOnline Tower UPS SmartOnline Modular Phase Tower UPS SmartOnline 3-Phase Tower UPS Network Power Management Powerlert Software esktop UPS Systems LIN-INTRTIV OPRTION Tower and Low-Profile UPS STNY OPRTION Tower and Low-Profile UPS Integrated Solutions Racks, ooling, PUs, KVMs 36 and ables
2 OW TO OOS UPS SYSTM It would be nice if utility power was always reliable, but it isn t. etween the aging grid, growing demand, severe weather and hazards lurking inside your own walls, your equipment is under constant attack. You can prevent equipment damage, data loss and downtime by installing a UPS system to regulate incoming power and provide battery backup during outages. Whether you re supporting racks of mission-critical servers in your data center or a single desktop computer in your home office, Tripp Lite can provide the UPS you need to get the job done. nd with Tripp Lite, you ll get more for your money. ut with so many models to choose from, how can you determine which UPS is best for your application? onsider the five questions on the next page to help you choose. IN IT ST! Try our interactive UPS selector guide at 2
3 ive asic Questions to onsider When hoosing a UPS System 1. o you need a Network/Server UPS or a esktop UPS? Network/Server UPS Systems protect equipment in high-availability environments like data centers. esktop UPS Systems protect computers, peripherals and other electronics in your home or office. You need a Network/Server UPS if you answer yes to any of these questions: Will the UPS support mission-critical equipment? Will the UPS support a load higher than 750 watts? Will the UPS be installed in a rack or rack enclosure? oes your equipment require pure sine wave power? o you want the UPS to have expandable runtime? Will the UPS support high-voltage ( V) loads? 2. ow much UPS capacity do you need? To estimate capacity requirements, add up the wattage of all the equipment you plan to connect. (Refer to the equipment manufacturer s documentation to find the wattage. If output is listed in amps, multiply by the voltage to estimate wattage. If you can t find documentation, refer to the equipment nameplate.) heck the UPS system specifications to see which models will handle your requirements. Note: This method provides a rough estimate, but we recommend that you use our UPS product selector at or contact your Tripp Lite representative for a more precise estimate. 3. Which input and output power connections do you need? heck the UPS specifications to make sure the UPS can connect to a compatible circuit/outlet in the installation location. You also need to make sure the UPS system s outlets match the plugs and voltage requirements of your equipment. You can provide additional outlets, placement flexibility and management capabilities by connecting one or more Tripp Lite PUs to the UPS output. 4. ow much battery backup runtime do you need? With an 80% load, included UPS batteries typically provide five to ten minutes of runtime. That s long enough to outlast most outages. If you need additional runtime, choose a UPS system that supports connecting external battery packs. o to for interactive battery backup runtime charts for every UPS model. You can see how battery pack options affect runtime at any wattage level, download traditional runtime chart Ps and determine the wattage requirements of your equipment. 5. What other UPS features do you need? Tripp Lite manufactures more than 200 different UPS systems suitable for a wide range of applications and budgets. See pp. 4-5 for a comparison of the key features available in each UPS family. 3
4 UPS TUR OMPRISON esktop UPS Systems XTR PROTTION / IR PITY XTR PROTTION / Standby Line-Interactive Line-Interactive / Protection Protection On-Line Protection O-UPS, Internet Office, OmniSmart, igital, Smart US, Small Network/Server UPS* Pro and Personal OmniVS and VR Series (Models 1500V or Less - Standby UPS Line-Interactive UPS See p. 5 for eaturespowr PROTTION (pp ) (pp ) More Information) POWR PROTTION vailable Load apacities 300V to 300V to 500V to 1400V 1500V 1500V Surge/Noise Protection Yes Yes Yes ata Line Protection Select Select Select Models Models Models Voltage Regulation No Yes Yes xpandable Runtime No Two Models Select Models ONVNIN ompact orm actors Low-Profile Low-Profile Tower or or Tower or Tower Rack/Tower Simple Operation Yes Yes Yes RN KUP POWR igh fficiency Most Most Most Models Models Models reen Outlet Technology O-UPS No No Models OMMUNITIONS N MNMNT iagnostic Ls Most Most Select Models Models Models Status Screen Select igital () Select Models Models Models Serial and/or US Ports Most Yes Yes Models Switchable Outlet anks No No Select Models Manageable via ost Most Yes Yes omputer Models entrally Manageable Most Yes Yes Models * lthough small Network/Server UPS Systems can be ideal for important desktop applications (such as protecting critical workstations), some Network/Server UPS Systems have high-speed cooling fans that may not be suitable for low-noise environments. ontact your Tripp Lite representative for assistance if you are considering this option. 4
5 Network/Server UPS Systems IR PITY XTR PROTTION / IR PITY Line-Interactive On-Line ot-swappable On-Line Protection Protection Protection SmartOnline SmartPro SmartPro SmartOnline SmartOnline ot-swappable SmartOnline Tower UPS Rack/Tower UPS Tower UPS Rack/Tower UPS Rack/Tower UPS 3-Phase UPS eatures (pp ) (pp. 6-11) (pp ) (pp ) (pp ) (pp ) POWR PROTTION vailable Load apacities 750V to 500V to 750V to 750V to 5kV to 20kV to 3kV 5kV 3kV 5kV 20kV 80kV Surge/Noise Protection Yes Yes Yes Yes Yes Yes xpandable Runtime Select Models Select Models Yes Yes Yes Yes Voltage Regulation Yes Yes dvanced dvanced dvanced dvanced (±2%) (±2% or ±3%) (±3%) (±3%) Pure Sine Wave Output Select Models ll Models Yes Yes Yes Yes >500V True On-Line Operation No No Yes Yes Yes Yes RN KUP POWR igh fficiency Most Models Yes Yes Yes Yes Yes igh Power actor One Model Most Most Most Most Yes Models Models Models Models conomy Mode Operation N/ N/ Yes Yes Yes Yes I VILILITY Input Voltage Range Wide Wide Very Wide Very Wide Very Wide Very Wide Industrial Overload apacity No No No No Yes Yes utomatic ypass No One Model Yes Yes Yes Yes ot-swappable attery Yes Yes Yes Yes Yes Yes ot-swappable Power Module(s) No One Model No No Yes Yes uilt-in N+1 Redundancy No No No No N+1 Models Modular Models OMMUNITIONS N MNMNT ontrol Panel Ls Ls or Ls or Ls and/or Ls and Ls and Serial and/or US Ports Yes Yes Yes Yes Yes Yes Switchable Outlet anks Select Most Models Yes Select No No Models Models Manageable via ost omputer Yes Yes Yes Yes Yes Yes Manageable via Network ard Select Yes Yes Yes Yes Yes Models entrally Manageable Yes Yes Yes Yes Yes Yes 5
6 NTWORK/SRVR UPS SmartPro Line-Interactive Rack/Tower UPS Systems SmartOnline P R I esktop (Line- Interactive) esktop (Standby) SmartPro 5KV 500V T U R S & P R O R M N 500-5,000V Internal atteries and xtended Runtime Options utomatic Voltage Regulation (VR) Rack/Tower/Stack daptable onserve Space Slim as 1U! SmartPro Rackmount/Tower UPS Systems provide more battery backup (up to 5000V) and premium features in compact cases (as slim as 1U) which make the best use of available rack space. Protect very pplication SmartPro Rackmount/Tower UPS Systems are available in a wide variety of capacities to protect every size computer application from downtime, damage and data loss due to power problems. SmartPro Rackmount/Tower UPS Systems provide protection against all types of power problems, including brownouts, blackouts, surges and line noise. Line-interactive operation also known as automatic voltage regulation (VR) automatically regulates incoming voltage to keep equipment working through low voltage (brownouts) and high voltage conditions* indefinitely, without draining battery power. SmartPro Rackmount/Tower UPS Systems provide reliable battery power to keep computers up and running through short blackouts and allow enough time to save data and shut down during longer ones. In addition, all outlets are backed by internal surge suppression and line noise filtering components to protect equipment from damage due to lightning and surges or malfunctions and poor performance due to line noise. * SMRT500RT1U models supply battery power during high voltage conditions. W R - W I N N I N T R I P P L I T R L I I L I T Y 6 I found Tripp Lite's product quality and customer support to be head-and-shoulders above the field. Kraft oods lane Watkins, Systems dministrator
7 xtend Runtime Select models accept external battery packs to provide extended runtime. Without enough runtime, businesses stand to lose up to $70,000 per hour according to a survey on the cost of lost productivity for an hour of network downtime.* * I. xtended Runtime harts xtending runtime is as simple as plugging in additional external battery packs. dapt to Rack/ Tower/Stack pplications dapt all models from rackmount to tower or stacking applications.* Removable rack hardware Optional base stands o to for interactive battery backup runtime charts for every UPS model. Manage Multiple Servers Multiple built-in communication ports provide the ability to simultaneously manage multiple servers without the need for accessories. Using Powerlert software, models with multiple communication ports will simultaneously provide intelligent communications, shutdown commands and reporting on multiple servers even if they are running different operating systems.* Intelligent communications allow you to check UPS status (including battery charge level) and power status as well as reboot switched outlet banks. * dditional Powerlert features: pages 30 and 31. Protect Telecom pplications Protect large telecom equipment and servers with a specially designed SmartPro Rackmount/Tower UPS System SMRT5000TL3U. The SMRT5000TL3U allows you to power and protect multiple pieces of high-voltage equipment from a single 208V circuit. In addition, the SMRT5000TL3U features two 120V outlets to support low-voltage monitors and peripherals used with high-voltage equipment. ontrol Individual Outlets Rack/Tower UPS with optional base stands. Prioritize the uptime of mission-critical loads during a power failure with switched outlet banks featured on select models. Switched outlet banks can be controlled independently through Powerlert. Use Powerlert to reboot a locked-up computer by cycling the power on and off to select outlets on the UPS system. You can also program Powerlert to shut down less important systems during an extended blackout, preserving battery runtime for critical equipment. * 1U models include hardware to adapt to tower mounting. Optional base stands (model: 2-9USTN) are available to adapt any combination of models, from 2U to 9U wide, to tower mounting. 7
8 eature ocus 1U SMRT1000RM1U Rear Panel 2U SMRT3000RM2U Rear Panel 3U* SMRT5000RT3U Power Module Rear Panel* * Includes 3U attery Module (not shown) to occupy a total of 6U rack space. 3U SMRT5000XMRXL Rear Panel 3U 8 SMRT5000TL3U Rear Panel
9 xtended Runtime apability Select models feature connectors that accept optional external battery packs for additional runtime. xternal batteries can be hot-swapped. o to for interactive runtime charts for every UPS model. Switched Outlet anks Prioritize the uptime of missioncritical loads during a power failure. Select models feature switched outlet banks that you can control independently through Powerlert software. Use Powerlert to reboot a locked-up computer or to shut down less important systems during extended blackouts, preserving battery runtime for critical equipment. ccessory ard Slot ccepts optional internal SNMPWR. SNMPWR provides network interface for monitoring and control via SNMP, Web or telnet, enabling remote reboots, shutdowns and more. Select models ( SNMP ) include a preinstalled SNMPWR. Variety of Output Options 15-, 20- and 30-amp outlets on select models ensure maximum connection flexibility. Multiple Server Support Up to four built-in communication ports on select models simultaneously provide shutdown commands and reporting on multiple servers. Short ircuit Protection reakers safeguard your equipment and the UPS. mergency Power Off (PO) jack included with all models allows remote emergency shutdown. omplete Performance onditions isplayed ront panel or Ls alert you to a variety of performance conditions, including line present, automatic voltage regulation, UPS load and replace battery. ypass Operation (not shown) SMRT3000RMO2U includes a bypass feature that allows the power module to be hot-swapped without powering down connected equipment. ront Panel attery Replacement (not shown) Most models feature a removable panel which allows for internal battery replacement.* Internal batteries can be hot-swapped. * Tripp Lite offers a complete line of replacement battery cartridges (R...); visit Specifications U L SNMP SNMP SNMP SNMP US SNMP SNMP US Typical Total Nominal Input/ Switched Output Runtime () xtended Rack Output Voltage Outlet Outlet US Serial Input Model apacity (alf/ull Load) Runtime Size (requency 60z) Quantity (Type) anks Ports Ports Plug SmartPro UPS Systems SMRT500RT1U 500V/300W 14.6/3.2 min. 1U 120V 7 (5-15R) 1x P SMRT750RM1U 750V/600W 4.8/16.2 min. 1U 120V 6 (5-15R) 2x P SMRT750RMXL2U 750V/600W () 20.7/8.5+ min. 2U 120V 6 (5-15R) 2x P SMRT1000RM1U 1000V/800W 14/4 min. 1U 120V 6 (5-15R) 2x P SMRT1000RM2U 1000V/800W 15/5.3 min. 2U 120V 6 (5-15R) 2x P SMRT1000RMXL2U 1000V/900W 18/6.3+ min. 2U 120V 8 (5-15R) 2x P SMRT1500RM2U 1500V/1350W 13/4.5 min. 2U 120V 8 (5-15R) 2x P SMRT1500RM2UN 1500V/1350W 13/4.5 min. 2U 120V 8 (5-15R) 2x P SMRT1500RMXL2U 1500V/1350W 14/4.9+ min. 2U 120V 8 (5-15R) 2x P SMRT1500RMXLN 1500V/1350W 14/4.9+ min. 2U 120V 8 (5-15R) 2x P SMRT2200RM2U 2200V/1920W 12/4.5 min. 2U 120V 4 (5-15R), 4 (5-15/20R) 2x P SMRT2200RM2UN 2200V/1920W 12/4.5 min. 2U 120V 4 (5-15R), 4 (5-15/20R) 2x P SMRT2200RMXL2U 2200V/1920W () 12/4.5+ min. 2U 120V 4 (5-15R), 4 (5-15/20R) 2x P SMRT2200RMXL2UP 2200V/1920W 12/4.5+ min. 2U 120V 4 (5-15R), 4 (5-15/20R) 2x P SMRT2200RMXLN 2200V/1920W () 12/4.5+ min. 2U 120V 4 (5-15R), 4 (5-15/20R) 2x P SMRT2600RM2U 2600V/2100W (,) 11/4+ min. 2U 120V 4 (5-15R), 4 (5-15/20R), 3x P 1 (L5-20R) SMRT3000RM2U 3000V/2250W () 10/3.5+ min. 2U 120V 8 (5-15/20R), 1 (L5-30R) 2x1 1 1 L5-30P SMRT3000RM2UN 3000V/2250W () 10/3.5+ min. 2U 120V 8 (5-15/20R), 1 (L5-30R) 2x1 1 1 L5-30P SMRT3000RMO2U 3000V/2880W () 11/4+ min. 2U 110/120/127V 6 (5-15R), 1 (L5-30R) 1x2, 1x4 1 1 L5-30P (50/60z) SMRT3000RMXL2U 3000V/2880W 10/3+ min. 2U 120V 8 (5-15/20R), 1 (L5-30R) 2x1 1 1 L5-30P SMRT3000RMXLN 3000V/2880W 10/3+ min. 2U 120V 8 (5-15/20R), 1 (L5-30R) 2x1 1 1 L5-30P SMRT5000RT3U 5000V/4000W () 38/16+ min. 6U 208V in; 208V + 10 (5-15R), 2 (5-15/20R), 120V out 1 (L6-30R), 1 (L14-30R) 8x1 2 2 L6-30P SMRT5000XMRXL 5000V/3750W () 20/8.5+ min. 3U 208V in; 208V + 8 (5-15/20R), 2 (L6-20R), 8x1 1 2 () L6-30P 120V out 1 (L6-30R) SMRT5000TL3U 5000V/3750W () 20/8.5 min. 3U 208V in; 208V + 2 (5-15R), 2 (L6-20R), 1 2 () L6-30P 120V (600V) out 1 (L6-30R) Model with hot-swappable power module. Model with expandable runtime. Model with. SNMP Model with pre-installed SNMPWR. xternal attery Packs and ccessories P24V28-2U 24V external battery pack and cable, 2U. Not expandable. R/LK 2-point connector. P24V70-3U 24V external battery pack and cable, 3U. xpandable. R/LK 2-point connector. P36V15-2U 36V external battery pack and cable, 2U. Not expandable. RY 2-point connector. P36V42-3U 36V external battery pack and cable, 3U. xpandable. RY 2-point connector. P48V24-2U 48V external battery pack and cable, 2U. Not expandable. LU 2-point connector. P48V60RT-3U 48V external battery pack and cable, 3U. xpandable. LU 2-point connector. P72V15-2U 72V external battery pack and cable, 2U. Not expandable. LK 3-point connector. P72V28RT-3U 72V external battery pack and cable, 3U. xpandable. LK 3-point connector. SNMPWR dds thernet (RJ45) network interface to UPS for remote monitoring and control via SNMP, Web, SS or telnet. NVIROSNS onnects to SNMPWR for remote temperature and humidity monitoring. lso monitors contact-closure devices. RLYIOR dds programmable contact-closure interface to compatible UPS systems. Includes six outputs and one input. 2-9USTN dapts UPS modules and battery packs for tower installation. One kit adjusts from 2U to 9U. Two kits adjust from 10U to 14U. 2POSTRMKIT eavy-duty 2-post rack mounting kit for 2U to 4U UPS modules and battery packs. Order one kit per module or battery pack. ertifications vary by model. ll models include an accessory card slot, 10 ft. input cord and mounting hardware for installation in standard 19 in. 4-post racks. 1U models also support 2-post rack installation. 2U and larger models require optional 2-post mounting hardware for 2-post rack installation. () onnecting an external battery pack reduces maximum output. See tripplite.com for more information. () Maximum output requires a user-supplied plug. See tripplite.com for more information. () Runtime varies with load, battery condition and other factors. + Runtimes are expandable using optional external battery packs. () Includes an RS-232 serial port and a contact-closure port. Visit for the latest specifications, including weights and dimensions. 9
10 NTWORK/SRVR UPS SmartPro Shallow-epth Line-Interactive Rack UPS Systems SmartOnline P R I esktop (Line- Interactive) esktop (Standby) SmartPro 3.6KV 1.5KV T U R S & P R O R M N 1,500-3,600V est-in-lass Mounting epth utomatic Voltage Regulation (VR) Optional xternal attery Packs for xtended Runtime Support Network/Telecom Wiring losets Shallow mounting depth matches popular network/telecom equipment and allows UPS systems to fit in confined spaces. igh load capacity and internal battery capacity allow you to attach more equipment safely without installing additional circuits and UPS systems. Shallow-depth SMRT3000RMXL, SMRT2200RMXL and the matching P48V48RT4U external battery pack include all hardware required for secure mounting in 2-post network/telecom racks. ombine with Tripp Lite s SR2POST or SR2POST25 2-post racks to create ideal solutions for organizing, protecting and powering important equipment in cramped network/telecom wiring closets. xtend Runtime Protect Sensitive quipment Line-interactive operation also known as automatic voltage regulation (VR) automatically adjusts incoming voltage to safe levels without draining battery power. Reliable battery backup keeps equipment operating through power failures. Pure sine wave output guarantees maximum stability and compatibility with sensitive equipment. ll outlets include network-grade surge suppression and noise filtering. xtended Runtime harts ll models accept external battery packs to provide extended runtime. Without enough runtime, businesses stand to lose up to $70,000 per hour according to a survey on the cost of lost productivity for an hour of network downtime.* * I. Lower Operating osts -to- efficiency up to 97% reduces power consumption and lowers operating costs. ach two watts saved by increased UPS efficiency saves an additional watt in cooling requirements. igher efficiency also lowers your facility s environmental impact. o to for interactive battery backup runtime charts for every UPS model. 10 2
11 eature ocus K K J J I SMRT1500RMXL Rear Panel K SMRT3000RMXL/SMRT2200RMXL Rear Panel xternal attery Pack onnector onnects to an external battery pack for extended battery backup runtime. xpandable battery packs can be daisy-chained for additional runtime expansion. ccessory ard Slot ccepts optional internal SNMPWR or RLYIOR. SNMPWR provides network interface for monitoring and control via SNMP, Web, SS or telnet, enabling remote reboots, shutdowns and more. Use with optional NVIROSNS to monitor temperature and humidity or to control and monitor alarms and security systems. RLYIOR provides a programmable contact closure interface with 6 outputs and 1 input. mergency Power Off (PO) Jack onnects to facility s emergency power off switch for emergency shutdown of the UPS system. I-ompliant US Port and RS-232 Serial Port (9) onnects to a computer s US or serial port for automatic shutdown during extended power failures. Use with Powerlert software* or the built-in power management utilities of Mac OS X, Linux and Windows. Powerlert -ROM and cabling are included. I 5-15R Outlets Select outlets can be switched on or off remotely through Powerlert software or SNMPWR, enabling connected equipment reboot or shutdown. 5-15/20R Outlets These 20-amp outlets accommodate 5-15P or 5-20P plugs. Select outlets can be switched on or off remotely through Powerlert software or SNMPWR, enabling connected equipment reboot or shutdown. L5-30R Outlet (SMRT3000RMXL only) This 30-amp outlet connects to an L5-30P twist-lock plug. harge Rate Switch Sets battery charger to higher or lower amperage. Increasing the amperage allows the UPS system to recharge batteries more rapidly when external battery packs are connected. ypass larm Switch nables or disables bypass alarm. In case of internal fault or battery depletion, the bypass routes power to the outlets. J Input reaker K Output reakers (SMRT3000RMXL only) Internal attery Replacement (not shown) Recyclable internal batteries last several years under normal conditions. removable front panel allows hot-swappable internal battery replacement* asy-to-read ontrol Panel ront panel Ls display a variety of power conditions, including line status, automatic voltage regulation, overload, on battery, check battery and more. Real-time updates allow you to respond to power problems before your equipment is placed at risk. * Tripp Lite offers a complete line of replacement battery cartridges (R...); visit * dditional Powerlert features: pages 30 and 31. Specifications US Nominal Input/ Switched Primary Output Typical Runtime () Output Voltage Outlet Outlet omm. Mounting Model apacity (alf/ull Load) (requency 60z) Quantity (Type) anks Ports Plug Type Option SMRT1500RMXL 1500V/1440W 14/6+ min. 120V 8 (5-15R) 3x1 RS-232, 5-15P 4-Post US, PO Rack (2U) SMRT2200RMXL 2200V/1900W 28/11+ min. 120V 4 (5-15R), 3x1 RS-232, 5-20P 2-Post 4 (5-15/20R) US, PO Rack (4U) SMRT3000RMXL 3000V/2880W (3600V/3600W 19/7.5+ min. () 120V 8 (5-15/20R), 3x1 RS-232, L5-30P 2-Post via optional hardwire) () 1 (L5-30R) US, PO (optional hardwire) Rack (4U) xternal attery Packs (ompatible with all RM models.) P48V48RT4U P48V24-2U P48V60RT-3U xpandable 4U battery pack optimized for SMRT3000RMXL and SMRT2200RMXL. Includes 2-post mounting hardware. Non-expandable 2U battery pack optimized for SMRT1500RMXL. Includes 4-post mounting hardware. xpandable 3U battery pack. Includes 4-post mounting hardware. ccessories SNMPWR dds thernet (RJ45) network interface to UPS for remote monitoring and control via SNMP, Web, SS or telnet. NVIROSNS onnects to SNMPWR for remote temperature and humidity monitoring. lso monitors contact-closure devices. RLYIOR dds programmable contact-closure interface to compatible UPS systems. Includes six outputs and one input. 2-9USTN dapts UPS modules and battery packs for tower installation. One kit adjusts from 2U to 9U. Two kits adjust from 10U to 14U. 2POSTRMKIT eavy-duty 2-post rack mounting kit for 2U to 4U UPS modules and battery packs. Order one kit per module or battery pack. 4POSTRILKIT Mounting kit for 4-post rackmount installation. Order one kit per module or battery pack. Model with expandable runtime. ertifications vary by model. ll models include an accessory card slot and 10 ft. input cord. () Included cord and plug can be removed to permit hardwire input for 3600V/3600W output capacity. () Runtime varies with load, battery condition and other factors. + Runtimes are expandable using optional external battery packs. () Typical runtime is 13/5 min. for optional hardwire input. Visit for the latest specifications, including weights and dimensions. 11
12 NTWORK/SRVR UPS SmartPro Line-Interactive Tower UPS Systems esktop (Standby) esktop (Line- Interactive) 3KV 750V Protect very pplication SmartPro Tower UPS Systems are available in a wide variety of capacities to protect every size computer application from downtime, damage and data loss due to power problems. SmartPro Tower UPS Systems provide protection against all types of power problems, including brownouts, blackouts, surges and line noise. Line-interactive operation also known as automatic voltage regulation (VR) keeps equipment working through low voltage (brownouts) and high voltage conditions indefinitely, without draining battery power. SmartPro Tower UPS Systems provide reliable battery power to keep computers up and running through short blackouts and allow enough time to save data and shut down during longer ones. In addition, all outlets stop damaging surges and filter disruptive line noise. ontrol Individual Outlets 750-3,000V Internal atteries and xtended Runtime Options utomatic Voltage Regulation (VR) xtend Runtime Select models accept external battery packs to provide extended runtime. Without enough runtime, businesses stand to lose up to $70,000 per hour according to a survey on the cost of lost productivity for an hour of network downtime.* * I. xtended Runtime harts Prioritize the uptime of mission-critical loads during a power failure with switched outlet banks featured on select models. Use Powerlert to reboot a locked-up computer by cycling the power on and off to select outlets on the UPS system. You can also program Powerlert to shut down less important systems during an extended blackout, preserving battery runtime for critical equipment. Manage Multiple Servers Multiple built-in communication ports provide the ability to simultaneously manage multiple servers without the need for accessories. Using Powerlert software, select models with multiple communication ports will simultaneously provide intelligent communications, shutdown commands and reporting on multiple servers even if they are running different operating systems.* o to for interactive battery backup runtime charts for every UPS model. * dditional Powerlert features: pages 30 and
13 eature ocus xtended Runtime apability Select models feature connectors that accept optional external battery packs for additional runtime. xternal batteries can be hot-swapped. o to for interactive runtime charts for every UPS model. Switched Outlet anks Prioritize the uptime of mission-critical loads during a power failure. Select models feature switched outlet banks that you can control independently through Powerlert software. Use Powerlert to shut down less important systems first, preserving battery runtime for critical equipment. Multiple Server ontrol Up to four built-in communication ports on select models simultaneously provide shutdown commands and reporting on multiple servers without the need for accessories. Variety of Output Options and 30-amp outlets ensure maximum connection flexibility. mergency Power Off (PO) jack on select models allows remote emergency shutdown. Tel/SL/thernet Surge Protection (select models, not shown) Protect Internet-connected or networked computers from damage on a single telephone or thernet line. SMRT3000VS Rear Panel ccessory ard Slot ccepts optional internal SNMPWR or RLYIOR. SNMPWR provides network interface for monitoring and control via SNMP, Web, SS or telnet, enabling remote reboots, shutdowns and more. Use with optional NVIROSNS to monitor temperature and humidity or to control and monitor alarms. RLYIOR provides programmable contact closure interface with 6 outputs and 1 input. attery Replacement Tripp Lite UPS batteries will protect equipment for several years with normal use. Most models feature a removable panel which allows for internal battery replacement*. Internal batteries can be hot-swapped. Short ircuit Protection Performance onditions isplayed ront panel Ls alert you to a variety of performance conditions, including line present, automatic voltage regulation, UPS load level and replace battery. * Tripp Lite offers a complete line of replacement battery cartridges (R...); visit Specifications US U L Typical Nominal Switched US Output Runtime () xtended Input/Output Voltage Outlet Outlet US Serial SNMP Input Model apacity (alf/ull Load) Runtime (requency 60z) Quantity (Type) anks Ports Ports Slot Plug SmartPro UPS Systems SMRT V/450W 16.2/5.6 min. 120V 6 (5-15R) P SMRT700SR 700V/450W 16.9/5.9 min. 120V 6 (5-15R) P SMRT700V 700V/450W 54.5/22.2 min. 120V or 230V in; 120V out 6 (5-15R) 1 1 Y 5-15P (14) SMRT750XL 750V/500W 20.7/10+ min. 100/110/120V 8 (5-15R) 1 1 Y 5-15P SMRT750SLT 750V/500W 17.8/6.5 min. 100/110/120V 8 (5-15R) 1 1 Y 5-15P SMRT V/705W 23/8 min. 120V 6 (5-15R) P SMRT1050SLT 1050V/650W 19/7 min. 100/110/120V 8 (5-15R) 1 1 Y 5-15P SMRT V/980W 20/7 min. 120V 6 (5-15R) 1x P SMRT1500SLT 1500V/900W 20/8 min. 100/110/120V 8 (5-15R) 1 1 Y 5-15P SMRT1500XL 1500V/980W 20/7+ min. 120V 6 (5-15R) 1x P SMRT2200VS 2200V/1600W 19/7 min. 120V 7 (5-15R), 2 (5-15/20R) 3x2 2 2 Y 5-20P SMRT2200SLT 2200V/1600W 13/5 min. 120V 6 (5-15/20R), 1 (L5-20R) 1 1 Y 5-20P SMRT2200VSXL 2200V/1600W 19/7+ min. 120V 7 (5-15R), 2 (5-15/20R), 1 (L5-20R) 3x1 2 2 Y 5-20P SMRT2200NT 2200V/1700W 27/11+ min. 120V 6 (5-15R) 2x1 3 () 5-15P SMRT3000VS 3000V/2250W 14/4+ min. 120V 7 (5-15R), 2 (5-15/20R), 1 (L5-30R) 3x2 2 2 Y L5-30P SMRT3000NT 3000V/2400W 23/7+ min. 120V 4 (5-15R), 4 (5-15/20R) 2x1 3 () L5-30P SMRT3000SLT 3000V/2250W 9/3.5 min. 120V 6 (5-15/20R), 1 (L5-30R) 1 1 Y L5-30P xternal attery Packs and ccessories P24V28-2U 24V external battery pack and cable, 2U. Not expandable. R/LK 2-point connector. P24V70-3U 24V external battery pack and cable, 3U. xpandable. R/LK 2-point connector. P36V15-2U 36V external battery pack and cable, 2U. Not expandable. RY 2-point connector. P36V42-3U 36V external battery pack and cable, 3U. xpandable. RY 2-point connector. P48V24-2U 48V external battery pack and cable, 2U. Not expandable. LU 2-point connector. P48V60RT-3U 48V external battery pack and cable, 3U. xpandable. LU 2-point connector. SNMPWR dds thernet (RJ45) network interface to UPS for remote monitoring and control via SNMP, Web, SS or telnet. NVIROSNS onnects to SNMPWR for remote temperature and humidity monitoring. lso monitors contact-closure devices. RLYIOR dds programmable contact-closure interface to compatible UPS systems. Includes six outputs and one input. Model with expandable runtime. ertifications vary by model. () Runtime varies with load, battery condition and other factors. + Runtimes are expandable using optional external battery packs. () Includes an RS-232 serial port and two contact-closure ports. Visit for the latest specifications, including weights and dimensions. 13
14 RKMOUNT/TOWR UPS NTWORK/SRVR UPS SmartOnline True On-Line Rack/Tower UPS Systems SmartOnline P R I esktop (Standby) esktop (Line- Interactive) SmartPro 20KV 750V T U R S & P R O R M N 14 2 eliver True On-Line, Pure Sine Wave, Zero Transfer Time Operation SmartOnline Rackmount/Tower UPS Systems provide mission-critical equipment with the highest level of power protection. oubleconversion technology continually converts incoming power into filtered power, and then resynthesizes it back into power with a pure sine wave. onstant on-line operation completely isolates sensitive equipment from every power problem on the line. SmartOnline models accept the widest range of incoming voltage and frequency variations, delivering the most consistently pure, highly regulated power: ±3% or ±2% V. SmartOnline Rackmount/Tower UPS Systems provide reliable battery power with zero transfer time to keep networks up and running through short blackouts and allow enough time to save data and shut down during longer ones. In addition, they stop damaging surges and filter disruptive line noise. TRU ON-LIN 750V - 20kV Zero Transfer Time, ouble onversion Wide Input Voltage Range with Precision-Regulated Output xtended Runtime Options utomatic Internal ypass Maintenance ypass and etachable PU Options Manage Multiple Servers Using Powerlert software, select models with multiple communication ports will simultaneously provide intelligent communications, shutdown commands and reporting on multiple servers even if they are running different operating systems.* Intelligent communications allow you to check UPS status (including battery charge level and runtime remaining) and power status as well as reboot switched outlet banks. * dditional Powerlert features: pages 30 and 31. ontrol Individual Outlets Switched outlet banks on select models can be controlled independently through Powerlert. Use Powerlert to reboot a locked-up computer by cycling the power on and off to select outlets on the UPS system. You can also program Powerlert to shut down less important systems during an extended blackout, preserving battery runtime for critical equipment. Save lectricity & Reduce osts SmartOnline UPS Systems are up to 97% efficient in economy mode, a potential increase of 10% or more versus comparable on-line UPS systems. conomy mode can make your data center significantly cooler, greener and more cost-effective.
15 Provide Maximum vailability with ot-swappable esign ot-swap the Power Module etachable PU ontinues Powering quipment ll SmartOnline Rackmount/Tower UPS Systems include an automatic internal bypass that ensures maximum availability of connected equipment by passing through utility power in the event of an internal fault or overload. ot-swappable models include two additional features that ensure continuous availability: a maintenance bypass switch and a modular design. When the switch is set to bypass, the power module can be removed for maintenance while the detachable PU remains installed, continuing to power connected equipment as long as utility power is present. ot-swappable models are designated by the symbol in the specifications chart. Select hot-swappable models (designated by the N+1 symbol) include dual power modules for built-in N+1 redundancy. dapt to Rack / Tower / Stack pplications dapt all models from rackmount to tower or stacking applications. Removable rack hardware Optional tower base stands (2-9USTN) isplay Power onditions ront-panel Ls and/or help you identify power problems and solutions. Single cabinet tower mount with optional base stands. Multiple cabinet tower mount with optional base stands. xtended Runtime harts xtend Runtime ll models accept external battery packs to provide extended runtime. Without enough runtime, businesses stand to lose up to $70,000 per hour according to a survey on the cost of lost productivity for an hour of network downtime.* * I. xtending runtime is as simple as plugging in additional external battery packs. o to for interactive battery backup runtime charts for every UPS model. 15
16 eature ocus xtended Runtime apability ll models feature connectors that accept optional external battery packs for additional runtime. xternal batteries can be hot-swapped. o to for interactive runtime charts for every UPS model. etachable ypass PU Passes through power to connected equipment if power module is removed for maintenance. Switched Outlet anks Select models feature switched outlet banks that you can control independently through Powerlert software. Server Support Up to two built-in communication ports on select models simultaneously provide shutdown commands and reporting on multiple servers without the need for accessories. ypass Operation bypass switch allows the power module to be removed for maintenance, repair or replacement while continuously passing through utility power to connected equipment. ccessory ard Slot ccepts optional internal SNMPWR or RLYIOR. SNMPWR provides network interface for monitoring and control via SNMP, Web, SS or telnet, enabling remote reboots, shutdowns and more. Use with optional NVIROSNS to monitor temperature and humidity or to monitor alarms and security systems. RLYIOR provides a programmable contact closure interface with 6 outputs and 1 input. Short ircuit Protection ircuit breakers help guard against input/output short circuits and overloads. mergency Power Off jack included with select models allows remote emergency shutdown. ll other models can perform emergency shutdown by attaching an optional cable (model , sold separately) to the communication port. The optional cable includes a 9 connector to allow server support and a jack to allow emergency shutdown. Standard Models Maximum vailability eatures: Internal ypass ot-swappable atteries SU2200RTXL2U UPS System Rear Panel with Internal atteries. 2U K J SU3000RTXL3U/ SU3000RTXR3U UPS System Rear Panel with Internal atteries. 3U K J K SU5000RT3U UPS System Rear Panel with Isolation Transformer and xternal attery Pack. 3U 7U Total 2U K 2U 16
17 I J ardwire, Single-Phase Input (select models) To convert select models to hardwire input and output, select optional hardwire input/output PUs. To add an input plug and outlets to SU6000RT3U and SU6000RT3UV select SUPM alternate back panel accessories. TL/SL/thernet Surge Protection (select models) Protect Internet-connected or networked computers from damage on a single telephone or thernet line with surge-protected jacks featured on select models. K Variety of Output Options 15-, 20- and 30-amp outlets on select models ensure maximum connection flexibility. ront Panel attery Replacement (not shown) 1,000 to 3,000V models feature a convenient front access door to replace internal batteries.* ll models allow hot-swap battery replacement. * Tripp Lite offers a complete line of replacement battery cartridges (R...); visit ot-swappable Modular Models Maximum vailability eatures: Internal ypass ypass Switch ot-swappable Power Module ot-swappable atteries 4U SU6000RT4U UPS System Rear Panel with Internal atteries. K K I 6U Total 3U SU10000RT3U UPS System Rear Panel with xternal attery Pack. Multiple PU options available. 3U K 2U SU5000XMRT2U Isolation Transformer Rear Panel. K SU16000RT4U UPS System Rear Panel with xternal attery Pack. 4U 8U Total 4U I K K 17
18 Total US Specifications U L US Input Outlet Output Typical Runtime () xtended Rack Voltage Nominal Quantity (Type) US Serial () Input Model apacity (alf/ull Load) Runtime Size Range () Output Voltage [Switched Outlet anks] Ports Ports Ports Plug SmartOnline Single-Phase UPS Systems (3-wire input) SU750RTXL2U 750V/600W 11/4+ min. 2U V 120V (100/ 6 (5-15R); [2x1] 1 1 () 5-15P 110/120V) SU750RTX2U 750V/675W 9/3+ min. 2U V 120V (100/110/115 6 (5-15R); [2x1] 1 1 () 5-15P 120/127V) SU1000RTXL2U 1000V/800W 14/4.5+ min. 2U V 120V (100/110/120V) 6 (5-15R); [2x1] 1 1 () 5-15P SU1000RTX2U 1000V/900W 14/4.8+ min. 2U V 120V (100/110/115 6 (5-15R); [2x1] 1 1 () 5-15P 120/127V) SU1500RTXL2U 1500V/1200W 14/5+ min. 2U V 120V (100/110/120V) 6 (5-15R); [1x2, 1x4] 1 1 () 5-15P SU1500RTX2U 1500V/1350W 14/4.2+ min. 2U V 120V (100/110/115 6 (5-15R); [2x3] 1 1 () 5-15P 120/127V) SU2200RTXL2U 2200V/1600W 14/4.5+ min. 2U V 120V (110/120V) 6 (5-15/20R); 1 1 () 5-20P 1 (L5-20R); [2x3] SU2200RTX2U 2200V/1800W 12/4+ min. 2U V 120V (100/110/115 6 (5-15/20R); 1 1 () 5-20P 120/127V) 1 (L5-20R); [2x3] SU3000RTXL2U 3000V/2500W 15/6+ min. 2U V 120V (100/110/115 6 (5-15/20R), 1 1 () L5-30P 120/127V) 1 (L5-30R); [2x3] SU3000RTXL3U 3000V/2400W 14/5+ min. 3U V 120V (110/120V) 4 (5-15R), 4 (5-15/20R), 1 1 () L5-30P 1 (L5-30R); [2x4] SU3000RTXL3UV 3000V/2400W 14/5+ min. 3U V 208/240V 6 (6-15/20R), 1 () L6-20P 2 (L6-20R); [1x2, 1x4] SU3000RTX3U 3000V/2700W 11/4+ min. 3U V 120V (100/110/115 4 (5-15R), 4 (5-15/20R), 1 1 () L5-30P 120/127V) 1 (L5-30R); [2x4] SU3000RTXR3U 3000V/2400W 30/12+ min. 3U V 120V (110/120V) 4 (5-15R), 4 (5-15/20R), 1 1 () L5-30P 1 (L5-30R); [2x4] SU3000RTXR3UW 3000V/2400W 30/12+ min. 3U V 120V (110/120V) ardwire 1 1 () ardwire SU5000RT3U 5kV/3.5kW 20/8+ min. I 7U V 208V + 120V (60z) 2 (L6-20R), 2 (L6-30R), 1 1 L6-30P 12 ( 5-15/20R) SU5000RT3UV 5kV/3.5kW 20/8+ min. I 5U V 208/240V 2 (L6-20R), 2 (L6-30R) 1 1 L6-30P SU5000RT4UV 5kV/4.5kW 11/3.5+ min. 4U V 208/240V 2 (L6-20R), 2 (L6-30R) 1 1 L6-30P SU5000RT4UT 5kV/4.5kW 11/3.5+ min. 6U V 208V + 120V (60z) 2 (L6-20R), 2 (L6-30R), 1 1 L6-30P 12 (5-15/20R) SU6000RT3U 6kV/4.2kW 20/8+ min. I 9U V 208/240V + 120V ardwire () 1 1 ardwire () SU6000RT3UV 6kV/4.2kW 20/8+ min. I 6U V 208/240V ardwire () 1 1 ardwire () SU6000RT3UVXL 6kV/4.2kW 30/12+ min. I 6U V 208/240V ardwire 1 1 ardwire SU6000RT4UV 6kV/5.4kW 8.5/2+ min. 4U V 208/240V 2 (L6-20R), 2 (L6-30R) 1 1 L6-30P SU6000RT4UV 6kV/5.4kW 8.5/2+ min. 4U V 208/240V 4 (19) 1 1 ardwire SU6000RT4UVW 6kV/5.4kW 8.5/2+ min. 4U V 208/240V ardwire 1 1 ardwire SU6000RT4UT 6kV/5.4kW 8.5/2+ min. 6U V 208/240V + 120V 2 (L6-20R), 2 (L6-30R), 1 1 L6-30P 4 (5-15R), 8 (5-15/20R), ardwire SU6000RT4UTW 6kV/5.4kW 8.5/2+ min. 6U V 208/240V + 120V 2 (L6-20R), 2 (L6-30R), 1 1 ardwire 4 (5-15R), 8 (5-15/20R), ardwire SU8000RT3U 8kV/7.2kW 13.5/5.5+ min. I 6U V 208/240V 4 (L6-20R), 2 (L6-30R) 1 1 ardwire SU8000RT3U1T 8kV/7.2kW 13.5/5.5+ min. I 8U V 208V + 120V (60z) 4 (L6-20R), 2 (L6-30R), 1 1 ardwire 12 (5-15/20R) SU8000RT3U 8kV/7.2kW 13.5/5.5+ min. I 6U V 208/240V 6 (19) 1 1 ardwire SU8000RT3UW 8kV/7.2kW 13.5/5.5+ min. I 6U V 208/240V ardwire 1 1 ardwire SU8000RT3UN50 8kV/7.2kW 13.5/5.5+ min. I 6U V 208/240V 4 (L6-20R), 2 (L6-30R) 1 1 S8265 () SU8000RT3UN50T 8kV/7.2kW 13.5/5.5+ min. I 8U V 208V + 120V (60z) 4 (L6-20R), 2 (L6-30R), 1 1 S8265 () 12 (5-15/20R) SU10KRT3U 10kV/9kW 12.5/4.3+ min. I 9U V 208/240V + 120V ardwire 1 1 ardwire SU10KRT3UV 10kV/9kW 12.5/4.3+ min. I 6U V 208/240V ardwire 1 1 ardwire SU10000RT3U 10kV/9kW 12.5/4.3+ min. I 6U V 208/240V 4 (L6-20R), 2 (L6-30R) 1 1 ardwire SU10000RT3U2T 10kV/9kW 12.5/4.3+ min. I 10U V 208V + 120V (60z) 4 (L6-20R), 2 (L6-30R), 1 1 ardwire 24 (5-15/20R) SU10000RT3U 10kV/9kW 12.5/4.3+ min. I 6U V 208/240V 6 (19) 1 1 ardwire Model with hot-swappable power module(s). Model with. Model with expandable runtime. 18
19 Total US Specifications N+1 N+1 N+1 N+1 N+1 N+1 N+1 N+1 N+1 N+1 N+1 U L US Input Output Typical Runtime xtended Rack Voltage Nominal Outlet US Serial () Input Model apacity (alf/ull Load) Runtime Size Range () Output Voltage Quantity (Type) Ports Ports Ports Plug SmartOnline Single-Phase UPS Systems (3-wire input) with ual Power Modules and uilt-in N+1 Redundancy (N+1 if load is 50% or less) SU12KRT4UW 12kV/10.8kW 8.5/2+ min. 8U V 208/240V ardwire 2 2 ardwire SU16KRT 16kV/14.4kW 13.5/5.5+ min. I 12U V 208/240V 2 (L6-30R), 8 (19) 2 2 ardwire SU16KRT-1T 16kV/14.4kW 13.5/5.5+ min. I 14U V 208/240V + 120V 2 (L6-30R), 8 (19), 2 2 ardwire 8 (5-15/20R), 4 (5-15R) SU16KRT8 16kV/14.4kW 13.5/5.5+ min. I 12U V 208/240V 8 (L6-20R), 2 (L6-30R) 2 2 ardwire SU16KRT 16kV/14.4kW 13.5/5.5+ min. I 12U V 208/240V 8 (19) 2 2 ardwire SU16KRTW 16kV/14.4kW 13.5/5.5+ min. I 12U V 208/240V ardwire 2 2 ardwire SU20KRT 20kV/18kW 12.5/4.3+ min. I 12U V 208/240V 2 (L6-30R), 8 (19) 2 2 ardwire SU20KRT-1T 20kV/18kW 12.5/4.3+ min. I 14U V 208/240V + 120V 2 (L6-30R), 8 (19), 2 2 ardwire 8 (5-15/20R), 4 (5-15R) SU20KRT8 20kV/18kW 12.5/4.3+ min. I 12U V 208/240V 8 (L6-20R), 2 (L6-30R) 2 2 ardwire SU20KRT 20kV/18kW 12.5/4.3+ min. I 12U V 208/240V 8 (19) 2 2 ardwire SU20KRTW 20kV/18kW 12.5/4.3+ min. I 12U V 208/240V ardwire 2 2 ardwire SmartOnline Split-Phase UPS Systems (4-wire input) SU5000RT4U 5kV/3.8kW 14/6+ min. 4U V (L-N) 208/240V + 120V 8 (5-15/20R), 1 1 () L14-30P 2 (L6-20R), 2 (L6-30R) SU6000RT4U 6kV/4.2kW 20/8+ min. 4U V (L-N) 208/240V + 120V 8 (5-15/20R), 1 1 () L14-30P 2 (L6-20R), 2 (L6-30R) SU8000RT4U 8kV/5.6kW 12/5+ min. 4U V (L-N) 208/240V + 120V 4 (5-15/20R), 2 (L6-20R), 1 1 () ardwire 2 (L6-30R), ardwire SU12000RT4U 12kV/8.4kW 20/7+ min. 8U V (L-N) 208/240V + 120V 5 (5-15/20R), 2 (L6-30R), 1 1 () ardwire 6 (19), ardwire SU12000RT4UW 12kV/8.4kW 20/7+ min. 8U V (L-N) 208/240V + 120V ardwire 1 1 () ardwire SU16000RT4U 16kV/11.2kW 12/5+ min. 8U V (L-N) 208/240V + 120V 5 (5-15/20R), 2 (L6-30R), 1 1 () ardwire 6 (19), ardwire SU16000RT4UW 16kV/11.2kW 12/5+ min. 8U V (L-N) 208/240V + 120V ardwire 1 1 () ardwire N+1 Model with built-in N+1 redundancy. Model with hot-swappable power module(s). Model with. Model with expandable runtime. Model escription xternal attery Packs and ccessories P24V28-2U 24V external battery pack and cable, 2U. Not expandable. R/LK 2-point connector. P24V70-3U 24V external battery pack and cable, 3U. xpandable. R/LK 2-point connector. P48V24-2U 48V external battery pack and cable, 2U. Not expandable. LU 2-point connector. P48V60RT-3U 48V external battery pack and cable, 3U. xpandable. LU 2-point connector. P72V15-2U 72V external battery pack and cable, 2U. Not expandable. LK 3-point connector. P72V28RT-3U 72V external battery pack and cable, 3U. xpandable. LK 3-point connector. P192V12-3U 192V external battery pack and cable, 3U. xpandable. LK 3-point connector. P192V18-4U 192V external battery pack and cable, 4U. xpandable. YLLOW INSULT 2-point connector. I P240V10RT3U 240V external battery pack and cable, 3U. xpandable. LK 3-point connector. SU5000XMRT2U 5kV transformer. 208V input. 208V+120V output. L6-30P input. 12 (5-15/20R)+1 (L6-30R) outlets. SU6000XMR2U 6kV transformer. 208/240V input. 208/240V+120V output. L6-30P or hardwire input. 4 (5-15R)+8 (5-15/20R)+1 (L6-30R) outlets + hardwire. 2-9USTN dapts UPS modules and battery packs for tower installation. One kit adjusts from 2U to 9U. Two kits adjust from 10U to 14U. 2POSTRMKIT eavy-duty 2-post rack mounting kit for 2U to 4U UPS modules and battery packs. Order one kit per module or battery pack. SNMPWR dds thernet (RJ45) network interface to UPS for remote monitoring and control via SNMP, Web, SS or telnet. NVIROSNS onnects to SNMPWR for remote temperature and humidity monitoring. lso monitors contact-closure devices. MOUSR dds interface for MOUS RTU industrial communications protocol, RS-422/485 and RS-232 to compatible UPS systems. RLYIOR dds programmable contact-closure interface to compatible UPS systems. Includes six outputs and one input. RLYIOMINI dds contact-closure port (9) to compatible single-phase 8-20kV UPS systems. Replaces US port. SUPM568W etachable PU for SU5000RT4U, SU6000RT4U and SU8000RT4U. ardwire input and output. Includes bypass switch. ertifications vary by model. ll models include an accessory card slot and mounting hardware for installation in standard 19 in. 4-post racks. 1U models also support 2-post rack installation. 2U and larger models require optional 2-post mounting hardware for 2-post rack installation. () Runtime varies with load, battery condition and other factors. Runtimes are expandable using optional external battery packs. () requency is 50/60z for single-phase models and 60z for split-phase models unless noted. Input voltage range varies withload. Maximum range shown. () Includes a combination RS-232 serial and contact-closure port. () Optional kits convert hardwire input/output to corded input and outlets. () ontact-closure ports () 50 ubbell S8265. lso supports hardwire input. Visit for the latest specifications, including weights and dimensions. 19
20 NTWORK/SRVR UPS SmartOnline True On-Line Tower UPS Systems SmartOnline P R I esktop (Standby) esktop (Line- Interactive) SmartPro 3KV 750V T U R S & P R O R M N eliver True On-Line, Pure Sine Wave, Zero Transfer Time Operation SmartOnline Tower UPS Systems provide mission-critical equipment with the highest level of power protection. ouble-conversion technology continually converts incoming power into filtered power, and then resynthesizes it back into power with a pure sine wave. onstant on-line operation completely isolates sensitive equipment from every power problem on the line. SmartOnline models accept the widest range of incoming voltage and frequency variations, delivering the most consistently pure, highly-regulated power: ±3% or ±2% V and ±0.05 z. SmartOnline Tower UPS Systems provide reliable battery power with zero transfer time to keep networks up and running through short blackouts and allow enough time to save data and shut down during longer ones. In addition, they stop damaging surges and filter disruptive line noise. ll models ensure maximum availability with an automatic internal bypass which passes through utility power in the event of an internal fault or overload. Manage Multiple Servers Using Powerlert software, simultaneously manage multiple servers even if they are running different operating systems.* Intelligent communications allow you to check UPS status (including battery charge level and runtime remaining) and power status. You can use Powerlert to reboot a locked-up server by cycling the power to select UPS outlets or shut down nonessential systems during a blackout, preserving runtime for critical equipment. * dditional Powerlert features: pages 30 and 31. TRU ON-LIN 750-3,000V Zero Transfer Time, ouble onversion Wide Input Voltage Range with Precision-Regulated Output utomatic Internal ypass Internal atteries and xtended Runtime Options xtend Runtime ll models accept external battery packs to provide extended runtime. Without enough runtime, businesses stand to lose up to $70,000 per hour according to a survey on the cost of lost productivity for an hour of network downtime.* * I. xtended Runtime harts 20 Save lectricity & Reduce osts SmartOnline UPS Systems are up to 97% efficient in economy mode, a potential increase of 10% or more versus comparable on-line UPS systems. conomy mode can make your data center significantly cooler, greener and more cost-effective. o to for interactive battery backup runtime charts for every UPS model.
21 US eature ocus xtended Runtime apability ll models feature connectors that accept optional external battery packs for additional runtime. Switched Outlet anks Prioritize the uptime of mission-critical loads during a power failure. ll models feature switched outlet banks that you can control independently through Powerlert software. Use Powerlert to reboot a locked-up computer or to shut down less important systems, preserving battery runtime for critical equipment. ccessory ard Slot ccepts optional internal SNMPWR or RLYIOR. Multiple Server Support uilt-in communication ports provide shutdown commands and reporting on multiple servers. Short ircuit Protection ircuit breakers help guard against input short circuits and system overloads. isplay ritical Operational onditions mergency Power Off SU3000XL Rear Panel ll models include a jack that allows remote emergency shutdown. Tel/Network Surge Protection Protect Internet-connected or networked computers from damage on a single telephone or thernet line. SU1000XL Rear Panel SmartOnline Tower UPS Systems feature a front panel or L display which displays a variety of UPS operational modes and conditions. This interface provides more information than comparable models, allowing you to react more rapidly to an alert before your systems are put at risk. Specifications Input Switched Output Typical Runtime () xtended Voltage Nominal Outlet US Serial Model apacity (alf/ull Load) Runtime Outlet Quantity (Type) Range () Output Voltage anks Ports Ports Input Plug SmartOnline UPS Systems SU750XL 750V/600W 11/4+ min. 6 (5-15R) V 120V (100/110/120V) 2x1 1 1 () 5-15P SU1000XL 1000V/800W 14/4.5+ min. 6 (5-15R) V 120V (100/110/120V) 2x1 1 1 () 5-15P SU1000X 1000V/900W 12.8/3.8+ min. 6 (5-15R) V 120V (100/110/120V) 2x P SU1500XL 1500V/1200W 14/4.5+ min. 6 (5-15R) V 120V (100/110/120V) 2x3 1 1 () 5-15P SU1500X 1500V/1350W 14/4.5+ min. 6 (5-15R) V 120V (100/110/120/127V) 2x P SU2200XL 2200V/1600W 14/4.5+ min. 6 (5-15/20R), 1 (L5-20R) V 120V (110/120V) 2x3 1 1 () 5-20P SU2200X 2200V/1800W 13/4.5+ min. 6 (5-15/20R), 1 (L5-20R) V 120V (100/110/120/127V) 2x P SU3000XL 3000V/2400W 14/5+ min. 4 (5-15R), 4 (5-15/20R), 1 (L5-30R) V 120V (110/120V) 2x4 1 1 () L5-30P SU3000X 3000V/2700W 13.2/4.1+ min. 8 (5-15/20R), 1 (L5-30R) V 120V (100/110/120/127V) 2x4 1 1 L5-30P xternal attery Packs and ccessories P24V70-3U P24V28-2U P48V60RT-3U P48V24-2U P72V28RT-3U P72V15-2U 24V external battery pack and cable. Tower or 2U rack. xpandable. Small R/LK connector. 24V external battery pack and cable. Tower or 2U rack. Not expandable. Small R/LK connector. 48V external battery pack and cable. Tower or 3U rack. xpandable. LU 2-point connector. 48V external battery pack and cable. Tower or 2U rack. Not expandable. LU 2-point connector. 72V external battery pack and cable. Tower or 3U rack. xpandable. LK 3-point connector. 72V external battery pack and cable. Tower or 2U rack. Not expandable. LK 3-point connector. SNMPWR dds thernet (RJ45) network interface to UPS for remote monitoring and control via SNMP, Web, SS or telnet. NVIROSNS RLYIOR Model with. onnects to SNMPWR for remote temperature and humidity monitoring. lso monitors contact-closure devices. dds programmable contact-closure interface to compatible UPS systems. Includes six outputs and one input. Model with expandable runtime. ertifications vary by model. ll models include an accessory card slot, 10 ft. power cord, PO jack and Tel/Network line surge protection. () Runtime varies with load, battery condition and other factors. Runtimes are expandable using optional external battery packs. () requency is 50/60z. Input voltage range varies with load. Maximum range shown. () Includes a combination RS-232 serial and contact-closure port. Visit for the latest specifications, including weights and dimensions. 21
22 RKMOUNT/TOWR UPS NTWORK/SRVR UPS SmartOnline Modular 3-Phase True On-Line Tower UPS Systems 160KV 40KV esktop (Standby) esktop (Line- Interactive) 22 eliver True On-Line, Pure Sine Wave, Zero Transfer Time Operation SmartOnline Modular 3-Phase UPS Systems provide mission-critical equipment with the highest level of power protection. oubleconversion technology continually converts incoming power into filtered power, and then resynthesizes it back into power with a pure sine wave. onstant on-line operation completely isolates sensitive equipment from every power problem on the line. SmartOnline Modular 3-Phase UPS Systems automatically correct the widest range of incoming voltages of any models in their class. wider voltage correction range saves battery power and decreases battery wear by up to 40%, reducing battery replacement costs. SmartOnline Modular 3-Phase models provide reliable battery power with zero transfer time to keep networks up and running safely through short blackouts and allow enough time to safely shut down or switch to generator backup during longer ones. In addition, all models stop damaging surges and filter disruptive line noise. SmartOnline Modular 3-Phase UPS Systems are ideal for protecting critical equipment in computing, networking or telecommunications environments. TRU ON-LIN 40-80kV (Up to 160kV in Parallel) 3-Phase ardwire (120/208V or 277/480V) N+1 Modular rchitecture 1+1 Parallel apability with Patented ual SP ontrol Low Ti for 1:1 enerator Sizing Zero Transfer Time, ouble onversion dvanced IT Rectifier and Inverter Technology with Power actor orrection (P) Real-Time Log of 500 vents Save Installation osts (1:1 enerator Sizing) SmartOnline Modular 3-Phase UPS Systems include a generatorfriendly design that lowers installation costs. The SmartOnline UPS System s high input power factor and igital Signal Processor (SP) technology create less than 4% input Total armonic istortion (Ti), enabling a 1:1 sizing of the UPS System to a generator set. enerators are affected by the Ti that a UPS system passes back through its input into the overall power system. If the Ti is high, managers are forced to oversize generators in order to compensate. With the SmartOnline UPS System s low Ti, generators run cooler and last longer, allowing managers to save installation costs by installing a generator with a capacity equal to their equipment load (a 1:1 ratio). In addition, low Ti eliminates the need to oversize cables and breakers and eliminates nuisance breaker tripping and overheated transformers.
23 Save Operating osts SmartOnline Modular 3-Phase UPS Systems include advanced IT inverter technology that provides the highest efficiency (up to 96% in economy mode) of any UPS system in their class. igh efficiency operation lowers UPS system operating and related cooling costs and lengthens UPS system service life. Since inverter components are smaller, SmartOnline models also save significant facility floor space compared to legacy systems. Include dditional vailability eatures manual bypass breaker as well as an automatic bypass function included on SmartOnline Modular 3-Phase UPS Systems ensure the constant availability of connected equipment by safely passing through power if the UPS system requires maintenance. In addition, a battery cold-start function (initiated through the control panel) allows you to restart your UPS system and connected equipment during an extended blackout for periodic system access or retrieval of vital data. Provide Optional xtended Service / Support Programs Start-Up and On-Site Service Programs are recommended and available separately to enhance the reliability of the installation. Preventative maintenance services are also available for added peace of mind. Provide Maximum System vailability with N+1 Modular rchitecture & 1+1 Parallel apability N+1 Modular rchitecture Maximum vailability with N+1 Redundancy Multiple, Redundant Power Modules ual, Redundant ontroller Power Supplies ll SmartOnline Modular 3-Phase UPS Systems include multiple, self-contained power modules that provide fail-safe redundancy. In an N+1 configuration, a power module can be hot-swapped (with the load powered) if maintenance is required. Modular rchitecture Provides N+1 (and reater) Redundancy quipment Load ( N ) UPS System Model 20kV 40kV 60kV 80kV SU40K N+1 N SU60K & SU60KTV N+2 N+1 N SU80K & SU80KTV N+3 N+2 N+1 N xternal attery abinet 20kV Power Module 20kV Power Module 20kV Power Module 20kV Power Module 80kV UPS System 1+1 Parallel apability Provides Redundancy N+2 40kV Redundancy 40kV Load onnect two SmartOnline UPS Systems in parallel (1+1) to provide redundancy for the power distribution system. If one UPS is removed or taken offline for maintenance, the second UPS supports the equipment load automatically without requiring additional programming. SmartOnline UPS Systems are parallel-ready and use a non-proprietary, wall-mounted parallel distribution panel. Patented dual SP technology provides state-of-the-art parallel control. Increases apacity onnect two SmartOnline Modular 3-Phase UPS Systems in parallel to double the capacity offered to a single equipment load. Note: UPS systems connected in parallel must have the same capacity and voltage. Parallel connection also requires a wall-mounted parallel tie cabinet. xternal attery abinet xternal attery abinet y xternal attery abinet 20kV Redundant Power Module 20kV Power Module 20kV Power Module 20kV Power Module 20kV Power Module 80kV UPS System 50% Support 50% Support 80kV UPS System y 80kV UPS System xternal attery abinet y xternal attery abinet N+1 80kV UPS System y 80kV UPS System 20kV Redundancy 60kV Load 80kV Load 100% Support 100% Support 160kV Load 23
24 eature ocus UPS System Power Module abinet The UPS System s power module cabinet delivers true on-line, pure sine wave power to connected equipment. xtended Runtime apability (rear panel access, not shown) 40kV models include internal batteries. 60kV and 80kV models require a stand-alone, hardwired external battery cabinet (available separately from Tripp Lite) to provide battery backup support. ll models accept connection of additional external battery cabinets for extended runtime. ontact Tripp Lite for a runtime solution customized for your application. dvanced ommunications apabilities RS-232 Interface Provides shutdown commands and reporting on a single server. ccessory ard Slot ccepts optional internal SNMPWR. SNMPWR provides network interface for monitoring and control via SNMP, Web, SS or telnet, enabling remote reboots, shutdowns and more. Use with optional NVIROSNS to monitor temperature and humidity or to control and monitor alarms and security systems. 1+1 Parallel Interface llows two UPS systems to support a single equipment load. ry-ontact Interface (including "PO" emergency power off function) llows remote emergency shutdown of the UPS system. lso allows the UPS system to monitor a variety of input/output conditions, including external battery module conditions. ardwire, 3-Phase (4-wire, wye) Output (rear panel access, not shown) onnects the power module directly to your equipment or a PU (power distribution unit). ardwire, 3-Phase (4-wire, wye) Input (rear panel access, not shown) onnects the power module directly to the 3-Phase utility power source. ooling ans Keep UPS system at optimal operating temperature, prolonging service life. Removable Mounting rackets, Rolling asters & Levelers Provide added mobility and stability during installation. Removable Mounting rackets Multiple, Redundant ot-swappable 20kV Power Modules ll SmartOnline Modular 3-Phase UPS Systems include multiple, selfcontained power modules that provide the ultimate level of fail- 20kV Redundant Power Module safe redundancy. In an N+1 configuration, a power module can be hotswapped (with the load powered) if maintenance is required. 24 SU80K/SU80KTV Rear Panel ypass Operation manual bypass breaker as well as an automatic static bypass ensure maximum I I I availability of connected equipment by safely passing through power if the UPS system requires maintenance. I Short ircuit Protection reakers safeguard your equipment, the UPS system and your electrical infrastructure against potential damage due to input or output short circuits and system overloads.
25 isplay & ontrol Panel This interface indicates a variety of UPS operational modes and conditions, allowing you to react more rapidly to an alert before your systems are put at risk. 1 Screen: lets you access more precise information than provided by Ls alone. Text and intuitive operational block diagrams communicate a variety of fault/warning and UPS system operational conditions. Real-Time vent Log Screen (Up to 500 vents Listed) vent log helps you decisively react to changing conditions by providing a broader context of UPS operation ynamic attery Management Screen Use the display and control buttons to select optional settings for charge current and battery equalization lengthening battery service life. lso use the control panel to cold start the UPS system. 2 L Set: indicates normal on-line operation, on-battery operation, bypass operation or an input fault condition. 3 Inverter On/Off uttons 4 Screen ontrol uttons 5 PO (mergency Power Off) utton: onsite safety measure (covered to protect against accidental contact) completely shuts down the UPS. Specifications U L US Included xternal attery Input/Output Input ommunication Ports Typical Internal abinets Voltage Voltage Range "Smart" Parallel ry SNMP/Web Output Runtime attery Strings (Required for (ardwire, 50/60z (requency RS-232 Interface ontact ccessory Model apacity alf/ull Load () (Quantity) 60kV & 80kV Models) uto-selecting) 60z) (9) (9) Interface Slot SmartOnline Modular 3-Phase UPS System Power Modules SU40K 40kV/32kW 13/5.5+ min /208V / ø, 4-wire V (plus ground), wye SU60K 60kV/48kW ontact Tripp Lite 120/208V / for ustomized 3ø, 4-wire V Runtime Solutions (plus ground), wye SU60KTV 60kV/48kW ontact Tripp Lite 277/480V / for ustomized 3ø, 4-wire V Runtime Solutions (plus ground), wye SU80K 80kV/64kW ontact Tripp Lite 120/208V / for ustomized 3ø, 4-wire V Runtime Solutions (plus ground), wye SU80KTV 80kV/64kW ontact Tripp Lite 277/480V / for ustomized 3ø, 4-wire V Runtime Solutions (plus ground), wye xternal attery abinets, Internal attery String and ccessories P480V26 +/- 240V hardwired external battery cabinet. Multiple cabinets can be daisy-chained. Matches UPS cabinet. P480V40 +/- 240V hardwired external battery cabinet. Multiple cabinets can be daisy-chained. Matches UPS cabinet. P480V55 +/- 240V hardwired external battery cabinet. Multiple cabinets can be daisy-chained. 10-year design life. P480V78 +/- 240V hardwired external battery cabinet. Multiple cabinets can be daisy-chained. 10-year design life. P480V103 +/- 240V hardwired external battery cabinet. Multiple cabinets can be daisy-chained. 10-year design life. P480V140 +/- 240V hardwired external battery cabinet. Multiple cabinets can be daisy-chained. 10-year design life. SUR V replacement internal battery string for SU40K only. SU40KMPK xternal maintenance bypass panel for SU40K only. Wall-mount. Kirk Key interlock system prevents sequence of operation errors. SU60KMPK xternal maintenance bypass panel for SU60K only. Wall-mount. Kirk Key interlock system prevents sequence of operation errors. SU80KMPK xternal maintenance bypass panel for SU80K only. Wall-mount. Kirk Key interlock system prevents sequence of operation errors. SU60KMPKX xternal maintenance bypass panel for SU60KTV only. Wall-mount. Kirk Key interlock system prevents sequence of operation errors. SU80KMPKX xternal maintenance bypass panel for SU80KTV only. Wall-mount. Kirk Key interlock system prevents sequence of operation errors. SUP2MP40K Parallel tie cabinet for 1+1 parallel connection of SU40K models only. Wall-mount. SUP2MP60K Parallel tie cabinet for 1+1 parallel connection of SU60K models only. Wall-mount. SUP2MP80K Parallel tie cabinet for 1+1 parallel connection of SU80K models only. Wall-mount. SUP2MP60KX Parallel tie cabinet for 1+1 parallel connection of SU60KTV models only. Wall-mount. SUP2MP80KX Parallel tie cabinet for 1+1 parallel connection of SU80KTV models only. Wall-mount. SNMPWR dds thernet (RJ45) network interface to UPS for remote monitoring and control via SNMP, Web, SS or telnet. NVIROSNS onnects to SNMPWR for remote temperature and humidity monitoring. lso monitors contact-closure devices. Model with. Model with hot-swappable power module(s). Model with expandable runtime. () Runtime varies with load, battery condition and other factors. 40kV models include internal batteries. 60kV and 80kV models do not include internal batteries and require external battery cabinets, sold separately. Runtimes for all models are expandable using additional external battery cabinets. Visit for the latest specifications, including weights and dimensions. 25
26 RKMOUNT/TOWR UPS NTWORK/SRVR UPS SmartOnline 3-Phase True On-Line Tower UPS Systems SmartOnline P R I esktop (Standby) esktop (Line- Interactive) SmartPro 30KV 20KV T U R S & P R O R M N 26 eliver True On-Line, Pure Sine Wave, Zero Transfer Time Operation SmartOnline 3-Phase UPS Systems provide mission-critical 3-phase equipment with the highest level of power protection. ouble-conversion technology continually converts incoming power into filtered power, and then resynthesizes it back into power with a pure sine wave. onstant on-line operation completely isolates sensitive equipment from every power problem on the line. SmartOnline models include a wide incoming voltage tolerance, automatically correcting a wide range of incoming voltages* to save battery power for when it's needed during a blackout. SmartOnline 3-Phase UPS Systems provide reliable battery power with zero transfer time to keep networks up and running safely through short blackouts and allow enough time to safely shut down during longer ones. In addition, they stop damaging surges and filter disruptive line noise. SmartOnline 3-Phase UPS Systems are ideal for protecting critical equipment in computing, networking or telecommunications environments. * Voltage orrection Range: V/ V. TRU ON-LIN 20-30kV Small-ootprint abinet ront-panel attery ccess Zero Transfer Time, ouble onversion IT Inverter Technology 3-Phase ardwire Input and Output (120/208V) Internal atteries and xtended Runtime Options eliver Superior Reliability SmartOnline 3-Phase UPS Systems provide some of the lowest T (total harmonic distortion) output available, allowing your connected equipment to continuously perform at its peak. In addition, SmartOnline 3-Phase models provide a 3:1 crest factor to safely support a variety of equipment, even equipment with wildly fluctuating power demands. Provide Maximum vailability manual bypass switch and automatic bypass function ensure the constant availability of connected equipment by safely passing through power even if the UPS system requires maintenance. In addition, a battery cold-start switch allows you to restart your UPS system and connected equipment during an extended blackout for periodic system access or retrieval of vital data.
27 Save Space SmartOnline 3-Phase UPS Systems feature the smallest footprints in their class. While many competitive solutions require two bulky modules that must be installed side by side, SmartOnline 3-Phase UPS Systems combine power and battery components into a single, smallfootprint module. SmartOnline models save valuable facility floor space in every environment. xtend Runtime ll models feature a robust internal battery capability. dditional internal batteries can be added to provide extended runtime. If more runtime is required, an optional stand-alone battery compartment can be added and configured with additional batteries. Without enough runtime, businesses stand to lose up to $70,000 per hour according to a survey on the cost of lost productivity for an hour of network downtime.* * I. xtended Runtime harts Simplify Runtime Scalability In addition to a space-optimized design, SmartOnline UPS Systems include convenient front-panel battery access that simplifies runtime scalability. robust internal battery capability can be easily extended by installing additional optional internal batteries through the front panel access door. Room for additional internal battery strings is built into each SmartOnline 3-Phase UPS System so runtime can be significantly extended without changing the UPS system s spacesaving footprint. SU20K3/3 models provide room for two additional internal battery strings. SU30K3/3 models provide room for one additional internal battery string, and SU20K3/3XR5 and SU30K3/3XR5 models provide room for three additional battery strings. Provide reater Product vailability Since SmartOnline 3-Phase UPS Systems are fully stocked, they feature the lowest lead time (between ordering and installation) in the industry. On average, SmartOnline 3-Phase UPS Systems ship within several days compared to the industry average of 3 to 4 weeks. o to for interactive battery backup runtime charts for every UPS model. Lower Your ost of Ownership Lower your cost of ownership with the superior efficiency of SmartOnline 3-Phase UPS Systems. xtremely efficient operation saves money by lowering electricity consumption. s an extra measure of efficiency, SmartOnline 3-Phase models feature a high power density (packing more capacity into a smaller footprint cabinet) which saves valuable facility space. Provide Optional xtended Service / Support Programs Start-up and on-site service programs are recommended and available separately to enhance the reliability of the installation. Preventative maintenance services are also available for added peace of mind. Include nhanced ommunication apability SmartOnline 3-Phase UPS Systems include three communications ports, an SNMP slot and a remote PO jack. Powerlert software provides power management, monitoring and control locally or remotely through TP/IP. Intelligent communications allow you to check UPS status (including battery charge level) and power status.* * dditional Powerlert features: pages 30 and Phase ccessories ase eployment Non-proprietary accessories are available to integrate SmartOnline 3-Phase UPS Systems into your existing infrastructure, including external maintenance bypass panels (with Kirk Key interlock), external battery cabinets and more. 27
28 eature ocus UPS System Rear Panel (Power & attery omponents in One Module) The UPS System's power components (located within the top half of the unit) deliver true on-line, pure sine wave power to connected equipment. The power components work with internal batteries (located within the bottom half of the unit) to supply connected equipment with battery backup during a blackout. The internal battery compartment includes vacant slots to accept additional battery strings for extended runtime. Power ompartment I ypass Operation: manual bypass switch as well as an automatic bypass function ensure maximum availability of connected equipment by safely passing through power when the UPS system requires maintenance. Internal attery ompartment Increase Runtime in the Same Small ootprint SU20K3/3XR5 and SU30K3/3XR5 models integrate an additional internal battery compartment into the UPS design without altering its small footprint. Within the two compartments, both models include 5 internal battery strings (for increased runtime) and room for 3 additional internal battery strings (for runtime scalability). SU20K3/3 and SU30K3/3 shown 28
29 xtended Runtime apability (front panel, not shown) ll models feature a robust internal battery capability. dditional internal batteries can be added to provide extended runtime. If more runtime is required, an optional, stand-alone battery compartment can be added and configured with additional batteries. o to for interactive runtime charts for every UPS model. Multiple Server Support Multiple built-in communication ports simultaneously provide shutdown commands and reporting on multiple servers without the need for accessories. Short ircuit Protection Multi-pole breakers safeguard your equipment, the UPS system and your electrical infrastructure against potential damage due to input or output short circuits and system overloads. ardwire, 3-Phase (4-wire, wye) Output onnects the power module directly to your equipment or a PU (power distribution unit). ardwire, 3-Phase (4-wire, wye) Input onnects the power module directly to the 3-phase utility power source. ccessory ard Slot ccepts optional internal SNMPWR or RLYIOR. SNMPWR provides a network interface for monitoring and control via SNMP, Web, SS or telnet, enabling remote reboots, shutdowns and more. Use with optional NVIROSNS to monitor temperature and humidity. RLYIOR provides a programmable contact closure interface. mergency Power Off (PO) PO jack allows remote emergency shutdown. attery old Start Restart your UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval. Rolling asters Provide added mobility during installation. ront Panel isplay OUTPUT LO front panel R: 50% R: 13.8 S: 50% S: 13.8 combination /L display indicates a variety of UPS T: 50% T: 13.8 operational modes and conditions. This 1 2 interface provides more information than comparable models, allowing you to react more rapidly to an alert before your systems are put at risk. 1 Screen: lets you access more precise information than provided by Ls alone. View over 45 separate fault/warning and UPS system operational conditions, including operational mode, alarm/shutdown conditions, input/output voltage/frequency, battery voltage, load percentage and more. 2 L Set: is organized into a flow chart that indicates UPS system operational status, including normal on-line operation, bypass operation (due to fault or overload) or on-battery operation (due to a blackout or severe brownout). Specifications U L US Included Optional dditional apacity Input ommunication Ports Typical Internal Internal for Optional Internal Input/Output Voltage Range "Smart" ontact ccessory Output Runtime attery Strings attery attery Strings Voltage (requency RS-232 losure S-400 ard Model apacity alf/ull Load () (Quantity) Strings (Quantity) (ardwired) 60z) (9) (9) (9) Slot SmartOnline 3-Phase UPS Systems SU20K3/3 20kV/16kW 13/5+ min /208V / Yes 3ø, 4-wire V (plus ground), wye SU20K3/3XR5 20kV/16kW 42/17+ min /208V / Yes 3ø, 4-wire V (plus ground), wye SU30K3/3 30kV/24kW 13/5+ min /208V / Yes 3ø, 4-wire V (plus ground), wye SU30K3/3XR5 30kV/24kW 25/11+ min /208V / Yes 3ø, 4-wire V (plus ground), wye Internal attery Pack and ccessories SUR V internal battery string (for all models). SU2030 dditional, stand-alone battery cabinet (for all models). Requires SUR2030 battery strings. apacity: 4 strings. SU20KMPK xternal maintenance bypass panel (for 20kV models only). Wall-mount. Three 70 breakers. Kirk Key interlock system prevents sequence of operation errors. SU30KMPK xternal maintenance bypass panel (for 30kV models only). Wall-mount. Three 100 breakers. Kirk Key interlock system prevents sequence of operation errors. SNMPWR dds thernet (RJ45) network interface to UPS for remote monitoring and control via SNMP, Web, SS or telnet. NVIROSNS onnects to SNMPWR for remote temperature and humidity monitoring. lso monitors contact-closure devices. RLYIOR dds programmable contact-closure interface to compatible UPS systems. Includes six outputs and one input. Model with. Model with hot-swap capability. Model with expandable runtime. () Runtime varies with load, battery condition and other factors. Runtimes for all models are expandable using additional internal battery strings and/or external battery cabinets. Visit for the latest specifications, including weights and dimensions. 29
30 RKMOUNT/TOWR UPS NTWORK POWR MNMNT Powerlert Software Monitors and ontrols undreds of UPS Systems, PUs or ooling Systems, plus NVIROSNS Modules Software-Only Solution Requires No dditional ardware or Licenses vailable R Included or ownload 30 Powerlert software monitors and controls power for hundreds of UPS systems, PUs or cooling systems and the equipment they support. Since Powerlert is a R, software-only solution, it saves network managers significant costs compared to competitive solutions that require additional hardware or license purchases.* Using JV and SNMP standards, Powerlert simplifies power management for every network from a single, server to a global enterprise. Powerlert allows managers to centrally monitor every UPS, PU and cooling system on their network. In addition, Powerlert allows users to set parameters for graceful, automatic file saves and system shut down in the event of an extended blackout. * R Powerlert included with select models. R download available at Reduces eployment Time Mass onfiguration of evices Powerlert saves time and money by allowing managers to mass configure multiple remote device settings from a single location. evice uto-iscovery Managers can set Powerlert to auto-discover devices in specific network segments or IP address ranges. Reduces Troubleshooting Time larm Log Powerlert speeds up alarm resolution by pooling all network alarms into a single, sortable easy-to-read list. larm entries feature intuitive color coding, including white (normal), yellow (warning) and red (critical). Recommended ction Messaging Powerlert takes the guesswork out of how to respond to alarms. When managers select a device from the Network Management Screen, the device s real-time power status is displayed along with the alarm s cause and recommended response. isco, the isco logo, and isco Systems are trademarks or registered trademarks of isco Systems, Inc. and/or its affiliates in the United States and certain other countries. o to for complete disclaimer. Simplifies Network Power Management SNMP ontrol ny UPS connected to Powerlert via a US or serial cable can now be monitored via SNMP without an internal SNMPWR and its additional IP address. Powerlert s built-in SNMP agent can make even a basic desktop UPS a monitored device on your network, visible to Powerlert NMS or any third-party NMS. larm Notification Powerlert keeps managers continuously apprised of conditions through s and SNMP traps, enabling them to proactively manage problems before they affect productivity. Individual Outlet ontrol Powerlert allows managers to reboot locked devices or preserve runtime for critical equipment by remotely controlling the outlet power of UPS and power distribution units that offer outlet control capability. Select UPS and PU devices can also be configured to perform custom, sequential startup and shutdown sequences. Redundant UPS System Management Powerlert is smart enough to manage multiple UPS systems connected to a single load. or example, when two UPS systems are connected to support two power supplies on a server, Powerlert is typically configured to gracefully shut down the server only after battery power is exhausted on both UPS systems. Network Shutdown ommands When a UPS communicates with Powerlert software or via internal SNMPWR, other computers on the network may also be dependent on the condition of the UPS. ny networked computers with Powerlert Network Shutdown gent can detect an outage and automatically shut down before UPS battery power is exhausted. Powerlert can also execute custom scripts upon any alarm condition. onvenient Web-rowser ccess When the internal SNMPWR is used, network managers can access its management interface from any networked computer via a secure, password-protected browser session (TTP or TTPS).
31 Powerlert s Power-Management rchitecture entralized Power Management UPS thernet Network Manager s omputer Supported by Single UPS System conomy Mode ontrol Manage the energy-saving economy mode settings of SmartOnline UPS Systems in real time, or define a schedule to switch between economy mode and full-time double conversion automatically. SNMP Power Management UPS UPS System with SNMPWR PU Switched or Monitored PU Powerlert Network Management Screen Powerlert allows managers to monitor and control hundreds of devices from a single interface. lick on any device listing to open up to four device power status screens at a time. NMS Management Managers can choose to access Powerlert through a third-party network management system (NMS). Internal SNMP/Web ard Using Tripp Lite s internal SNMP/Web management cards (Model # SNMPWR) or built-in network interface, managers can make UPS systems and select PUs fully manageable (monitored and controlled) nodes on their network. Password-protected for increased security lash-upgradeable for enhanced manageability Real-time clock and NTP-compatibility Real-Time Power Status Screens ommunicate with SNMPWR through: 3rd-Party SNMP Tool Telnet/SS Web rowser (TTP/TTPS) UPS UPS System with SNMPWR nvironmental Sensor Using Tripp Lite s nvironmental Sensor (Model # NVIROSNS, available separately) and SNMPWR, managers can monitor external temperature/ humidity and contact-closure inputs. Local Power Management UPS Multiple omputers Supported by Single UPS System UPS UPS Redundant Protection: Single omputer Supported by Multiple UPS Systems Real-Time Power Status Screen Managers can view power events in real time, responding to power problems before they affect network performance. Visit for the latest Powerlert downloads and updates. 31
32 SKTOP UPS OmniSmart, igital, Smart US, OmniVS and VR Series Line-Interactive Tower and Low-Profile UPS Systems SmartOnline P R I OmniSmart, igital, Smart US, Omni VS and VR Series esktop 1500V Solutions SmartPro 300V T U R S & P R O R M N 300-1,500V utomatic Voltage Regulation (VR) ata Line Surge Protection Options xtended Runtime Options Protect very pplication OmniSmart, igital, Smart US, OmniVS and VR Series UPS Systems are available in a wide variety of capacities to protect every size computer application from downtime, damage and data loss due to power problems. These UPS systems provide protection against all types of power problems, including brownouts, blackouts, surges and line noise. Line-interactive operation also known as automatic voltage regulation (VR) keeps equipment working through low voltage (brownouts) indefinitely, without draining battery power. OmniSmart, igital, Smart US, OmniVS and VR Series UPS Systems provide reliable battery power to keep computers up and running through short blackouts and allow enough time to safely shut down during longer ones. igital UPS Systems include an status screen that shows power conditions in real time. Monitor input voltage, battery charge level, load status and other power conditions at a glance. o to for interactive battery backup runtime charts for every UPS model. Protect Systems On Telephone, thernet or oaxial Lines Select UPS systems include surge-protected jacks that safeguard equipment against damaging surges traveling on the telephone, thernet or coaxial lines. In addition to protecting equipment against surges, reliable battery backup power maintains Internet, network or coaxial connections during brief blackouts. utomatically Shut own Unattended Systems ll models feature at least one built-in communication port. Use with included cabling and Powerlert software (available as a R download) to automatically save open files and shut down unattended equipment during an extended blackout. Powerlert software waits for a user-specified length of time (during which on-screen notifications are displayed) before saving data and shutting down connected equipment. SMRT550USW model also includes Watchog monitoring/rebooting software to automatically reboot locked-up equipment perfect for kiosk, point-of-sale or other unattended applications. 32
33 eature ocus I VR750U ata Line Surge Protection Protect computers from damage on the telephone, thernet or coaxial line with surge-protected jacks on select models. utomatic ata Protection t least one built-in communication port connects all models to a P or workstation. Use with R Powerlert software* and included cabling to automatically save open files and shut down equipment during an extended blackout. * R download. Specifications ottom Panel (not shown) OMNIVS1500XL Rear Panel attery-supported and Surge-Protected Outlets (for computers and monitors) ll models include receptacles that provide reliable battery support for computers and monitors during a blackout as well as complete surge suppression and line noise filtering. Surge-Only Protected Outlets (for printers and peripherals) Select models include receptacles that provide complete surge suppression and line noise filtering for printers and peripherals. I Performance onditions isplayed ll UPS Systems feature either Ls or an screen to alert you to potential power problems. Space-Saving abinets attery ccess Widely Spaced Outlets xtended Runtime apability SMRT1000 Rear Panel SMRT1500 Rear Panel US U L Output Typical Runtime () xtended Outlet omm. ata Line US Model apacity (alf Load) Runtime Quantity (5-15R) Ports Protection OmniSmart UPS Systems OMNISMRT300PNP 300V/180W 29.8 min. 3 US Tel/Modem OMNISMRT V/300W 14.6 min. 6 (3 surge-only) US Tel/Modem OMNISMRT V/450W 8.3 min. 6 (3 surge-only) US, 9 Serial Tel/Network OMNISMRT V/705W 23 min. 6 US OMNISMRT V/940W 24 min. 6 US igital UPS Systems OMNI V/350W 13.8 min. 8 (4 surge-only) US OMNI V/420W 11.4 min. 8 (4 surge-only) US OMNI V/475W 10 min. 8 (4 surge-only) US SMRT V/500W 10 min. 8 (4 surge-only) US Tel/Modem, oax SMRT V/700W 12 min. 8 US, 9 Serial Tel/Network SMRT1300T 1300V/720W 10 min. 8 (4 surge-only) US Tel/Network, oax OMNI1500T 1500V/810W 7.5 min. 10 (5 surge-only) US Tel/Network, oax SMRT V/900W 13 min. 8 US, 9 Serial Tel/Network SMRT1500T 1500V/900W 10 min. 10 (5 surge-only) US Tel/Network, oax SMRT1500XL 1500V/900W 12+ min. 8 US, 9 Serial Tel/Network Smart US UPS Systems SMRT550US 550V/300W 14.8 min. 6 (3 surge-only) US Tel/Modem SMRT550USW 550V/300W 15 min. 6 (3 surge-only) US Tel/Modem SMRT750US 750V/450W 8.3 min. 6 (3 surge-only) US Tel/Network OmniVS UPS Systems OMNIVS V/475W 11.5 min. 7 (1 surge-only) US Tel/Network OMNIVS V/500W 14 min. 8 (2 surge-only) US Tel/Network OMNIVS V/940W 8.5 min. 8 (3 surge-only) US Tel/Network OMNIVS1500XL 1500V/940W 13+ min. 8 (2 surge-only) US Tel/Network VR Series UPS Systems VR550U 550V/300W 5.5 min. 8 (4 surge-only) US Tel/Modem VR650UM 650V/325W 10 min. 8 (4 surge-only) US Tel/Modem VR700U 700V/350W 8.6 min. 8 (4 surge-only) US Tel/Modem VR700UXRM 700V/350W 11.8 min. 8 (4 surge-only) US Tel/Modem VR750U 750V/450W 8.6 min. 12 (6 surge-only) US Tel/Modem VR900U 900V/480W 8.4 min. 12 (6 surge-only) US Tel/Modem ull-isolation UPS Systems (Include built-in isolation transformer.) OMNI500ISO 500V/300W 11 min. 3 US OMNI750ISO 750V/500W 31.3 min. 6 US OMNI1000ISO 1000V/700W 24 min. 6 US xternal attery Packs P24V15RT2U 24V external battery pack and cable. Tower or 2U rack. Not expandable. Small R/LK connector. P24V28-2U 24V external battery pack and cable. Tower or 2U rack. Not expandable. Small R/LK connector. P24V70-3U 24V external battery pack and cable. Tower or 3U rack. xpandable. Small R/LK connector. Model with. Model with expandable runtime. Model with audible alarm muted by default. ertifications vary by model. ll models have nominal 120V, 60z input/output and 5-15P input plug. () Runtime varies with load, battery condition and other factors. + Runtimes are expandable using optional external battery packs. Visit for the latest specifications, including weights and dimensions. 33
34 SKTOP UPS O-UPS, Internet Office, Pro and Personal Standby Tower and Low-Profile UPS Systems SmartOnline P R I esktop (Standby) 1400V esktop (Line- Interactive) SmartPro 300V T U R S & P R O R M N 300-1,400V ata Line Surge Protection Options Space-Saving abinets Protect very pplication esigned for desktop applications, O-UPS, Internet Office, Pro and Personal UPS Systems are available in a wide variety of capacities to protect every size computer from downtime, damage and data loss due to power problems. They provide protection against all types of power problems, including brownouts, blackouts, surges and line noise. They provide reliable battery power to keep computers up and running through short blackouts and brownouts, allowing enough time to save data and shut down during longer ones. Protect Internet-onnected & Networked Systems omputers connected to the Internet or thernet require additional protection against damaging surges traveling on phone or network lines. Select models include surge-protected jacks which safeguard modems and other communication hardware. o to for interactive battery backup runtime charts for every UPS model. Protect the Planet & Save Money O-UPS Systems use less electricity than conventional models, reducing your costs and your environmental impact: reen Outlet technology automatically cuts power to idle peripherals when your computer is turned off or in standby mode.* Superior power efficiency (up to 99%) conserves energy around the clock. co-friendly design and recyclable materials minimize hazardous substances and waste. * US connection required. utomatically Shut own Unattended Systems Most models feature a built-in communication port. Use with included cabling and Powerlert software (available as a R download) to automatically save open files and shut down unattended equipment during an extended blackout. Powerlert software waits for a user-specified length of time (during which on-screen notifications are displayed) before safely shutting down connected equipment. W R - W I N N I N T R I P P L I T R L I I L I T Y 34 Tripp Lite was the only power protection company I wanted to deal with. Xerox ngineering Systems Rick Santina, Network Manager
35 eature ocus ront Panel (not shown) INTRNT750U ottom Panel (not shown) INTRNTOI500 Rear Panel ata Line Surge Protection Protect Internet-connected or networked Ps from damage on the thernet and/or telephone line with surge-protected jacks featured on select models. utomatic ata Protection uilt-in communication port connects select models to a P or workstation. Use with R Powerlert software* and included cabling to automatically save open files and shut down equipment during an extended blackout. * R download. attery-supported and Surge-Protected Outlets (for Ps and monitors) ll models include outlets that provide reliable battery support for Ps and monitors during a blackout as well as surge suppression and line noise filtering. Surge-Only Protected Outlets (for printers and peripherals) Select models include outlets that provide (cont.) Specifications surge suppression and line noise filtering for printers and peripherals. These outlets allow you to connect and protect peripherals without overloading the UPS system and diverting precious battery support. attery Replacement Panel Tripp Lite UPS batteries will protect equipment for several years with normal use. Select models feature a removable panel which allows battery replacement.* * Tripp Lite offers a complete line of replacement battery cartridges (R...); visit Widely Spaced Outlets Select models feature outlets that accept multiple transformers without blocking access to other outlets. Space-Saving abinets ll models feature space-saving cabinets. Select models feature low-profile cabinets. Performance onditions isplayed Most models feature Ls to alert you to potential power problems before they affect your equipment. O650 and O850 feature an status screen. reen Outlet Technology (not shown) O-UPS Systems include special energy-saving outlets. The UPS system automatically cuts power to the energy-saving outlets when it detects that your computer is turned off or in standby mode. (US connection required.) US U L Output Typical Runtime () Outlet ata Line orm US Model apacity (alf Load) Quantity (5-15R) omm. Ports Protection actor Internet Office UPS Systems INTRNTOI V/150W 10 min. 6 (3 surge-only) Tel/Network Low-Profile INTRNT350U 350V/180W 11.3 min. 6 (3 surge-only) US Tel/Modem Low-Profile INTRNT350SR 350V/180W 10 min. 6 (3 surge-only) 9 Serial Tel/Modem Low-Profile INTRNTOI V/280W 14.8 min. 6 (3 surge-only) US Tel/Network (2) Tower INTRNT550U 550V/300W 5.6 min. 8 4 surge-only) US Tel/Modem Low-Profile INTRNT550SR 550V/300W 6 min. 8 (4 surge-only) 9 Serial Tel/Modem Low-Profile INTRNT600U 600V/300W 9.9 min. 8 (4 surge-only) US Tel/Modem Low-Profile INTRNTOI V/425W 11.2 min. 6 (3 surge-only) US Tel/Network Tower INTRNT750U 750V/450W 9.4 min. 12 (6 surge-only) US Tel/Modem Low-Profile INTRNT900U 900V/480W 8.7 min. 12 (6 surge-only) US Tel/Modem Low-Profile Pro UPS Systems PRO V/345W 14.5 min. 6 (3 surge-only) US Tel/Network Tower PRO V/705W 23 min. 6 US Tower PRO V/940W 24 min. 6 US Tower Personal UPS Systems PRS V/180W 16.8 min. 3 Tower V/180W 10 min. 6 (3 surge-only) Low-Profile PRS V/280W 14.8 min. 3 US Tower O-UPS Systems O350UPS 350V/180W 11.3 min. 6 (3 surge-only) US Tel/Modem Low-Profile O550UPS 550V/300W 10 min. 8 (4 surge-only) US Tel/Modem Low-Profile O650UPSM 650V/325W 11 min. 8 (4 surge-only) US Tel/Modem Low-Profile O750UPS 750V/450W 9.4 min. 12 (6 surge-only) US Tel/Modem Low-Profile O900UPSM 900V/480W 9.2 min. 12 (6 surge-only) US Tel/Modem Low-Profile O-UPS Systems with O V/325W 5.3 min. 8 (4 surge-only) US Tel/Modem Low-Profile O V/425W 10 min. 12 (6 surge-only) US Tel/Modem Low-Profile Model with. Model with audible alarm muted by default. ertifications vary by model. ll models have nominal 120V, 60z input/output and 5-15P input plug. () Runtime varies with load, battery condition and other factors. Visit for the latest specifications, including weights and dimensions. 35
36 INTRT SOLUTIONS Tripp Lite Manufactures More Than 2,500 Vendor-Neutral IT Infrastructure Solutions! Rack & ooling Solutions Tripp Lite makes more than 100 I-compliant rack enclosures, open frame racks, wall-mount racks, close-coupled cooling solutions and rack accessories. Power istribution Units (PUs) Tripp Lite makes more than 100 basic, metered, monitored and switched rack PUs in horizontal (1U/2U) and vertical (0U) form factors. KVM/onsole Solutions Tripp Lite makes more than 50 KVM switches, rack consoles and IP console servers, with or without built-in remote access (KVM over IP), built-in monitor, multiuser support and at5/utp cabling. ables and onnectivity Tripp Lite makes hundreds of cables, adapters and patch panels to connect high-speed data networks and power outlets to switches, routers and servers in high-density environments. Working on an IT infrastructure expansion or upgrade? Visit for help from our experienced project engineers! istributed y: Tripp Lite World eadquarters: 1111 W. 35th Street hicago, IL US opyright 2013 Tripp Lite. ll trademarks are the sole property of their respective owners. Photos and illustrations may differ from actual products. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice
UPS SYSTEMS. Tripp Lite UPS Systems. INDEX Intelligent, Line-Interactive Operation
UPS SYSTMS Tripp Lite UPS Systems The most reliable and cost-efficient solutions available for protecting and supporting critical systems in any environment. INX Intelligent, Line-Interactive Operation
UPS SYSTEMS. Tripp Lite UPS Systems. Introduction. Network/Server UPS Systems. Network Power Management. Desktop UPS Systems. Integrated Solutions
UPS SYSTMS Tripp Lite UPS Systems Reliable, efficient, manageable power and battery backup Reliable, efficient, manageable power and battery backup Reliable, efficient, manageable power and battery backup
Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications
W H I T E P A P E R Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications Executive Summary One of the fundamental decisions in the design of data centers, server rooms
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications
SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial
SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMART500RT1U Description Tripp Lite's SMART500RT1U intelligent, line-interactive rack/tower uninterruptible
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS, Sine
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SMART1000RM1U Description Tripp Lite SMART1000RM1U 1000VA / 1kVA / 800 watt line interactive,
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS,
Model #: SMART2200CRMXL
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: [email protected] Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /
Welcome to the Tripp Lite UPS Systems Basics training module, part of Tripp Lite's "Products Expert" training course. 2008 Tripp Lite.
Welcome to the Tripp Lite UPS Systems Basics training module, part of Tripp Lite's "Products Expert" training course. 2008 Tripp Lite. All rights reserved. The policy of Tripp Lite is one of continuous
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMARTINT3000VS Highlights 3kVA / 3000VA / 2250W line interactive tower UPS system 230V
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SM1000RM1UTAA Description Tripp Lite SM1000RM1UTAA 1000VA / 1kVA / 800 watt line
Tough Decision: On-Line or Line-Interactive UPS?
W H I T E P A P E R Tough Decision: On-Line or Line-Interactive UPS? How to Choose the Right Protection for Your Network Executive Summary In today s data-driven, technology-dependent world, no organization
Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system
Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system Model #: SMART500RT1U 500VA line interactive 1U rack/tower UPS 7 outlets with 1 switchable load bank Simultaneous
SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial
SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMX750SLT Highlights 750VA line interactive tower UPS; Sine wave output 220/230/240V nominal
SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial
SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX1000RT2U Highlights 1kVA / 1000VA / 900W line-interactive 2U rack/tower UPS, Sine
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port MODEL NUMBER: OMNIVS1500 Highlights 1500VA / 1.5kVA tower 120V line-interactive UPS Corrects brownouts and overvoltages from 75 to 147V
Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V
SmartPro VS Tower UPS System Intelligent, line-interactive power management system Model #: SMART2200VS 2200VA / 2.2kVA line interactive tower UPS Maintains 120V nominal output over an input range of 79
3U, 2200 VA Audio/Video Pure Sine Wave UPS System
3U, 2200 VA Audio/Video Pure Sine Wave UPS System MODEL NUMBER: HTR22-3U Description Tripp Lite's HTR22-3U Pure Sine Wave 2200VA/1600W on-line, double-conversion UPS system prevents media data loss, equipment
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
Internet Office 750VA Ultra-compact Standby 120V UPS with USB port
Internet Office 750VA Ultra-compact Standby 120V UPS with USB port MODEL NUMBER: INTERNET750U Highlights 750VA ultra-compact 120V standby UPS Maintains AC output during power failures 6 UPS battery supported
Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System
Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System MODEL NUMBER: HTR05-1U Description Tripp Lite's HTR05-1U AVR Series intelligent, Automatic Voltage Regulated
SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial
SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial MODEL NUMBER: SMART1500SLT Highlights 1.5kVA / 1500VA line interactive tower UPS; Sine wave output
DATA CENTER SOLUTIONS
DATA CENTER SOLUTIONS Nobody Makes Better Data Center Equipment Maximize availability, manageability and efficiency with cost-effective solutions from a dependable partner. Provide reliable, efficient
Internet Office 500VA Tower Standby 120V UPS with USB port
Internet Office 500VA Tower Standby 120V UPS with USB port MODEL NUMBER: INTERNETOFFICE500 Highlights 500VA tower 120V standby UPS Maintains AC output during power failures 3 UPS battery supported outlets,
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets MODEL NUMBER: BC600SINE Highlights 600VA tower 120V standby UPS with SINE WAVE output Maintains AC output during power
Internet Office UPS System Standby UPS for PCs, workstations and more
Internet Office UPS System Standby UPS for PCs, workstations and more Model #: INTERNETOFFICE500 500VA standby tower UPS system Offers battery-derived AC output during blackouts and brownouts starting
BC Pro UPS System Standby UPS System
BC Pro UPS System Standby UPS System Model #: BCPRO1400 1400VA standby, tower UPS system Offers battery derived AC output during blackouts and brownouts starting at 99V 6 protected AC outlets (NEMA 5-15R)
The CyberPower Story. A History of Firsts. Global Distribution 1.877.297.6937 UPS SYSTEMS
UPS SYSTS UPS SYSTS The yberpower Story The growth of yberpower Systems is attributable to a strategic plan that engages our own award-winning international research and development team in the design
Practical Power Guidelines for Cisco VoIP and Internet Telephony Applications
www.tripplite.com Practical Power Guidelines for Cisco VoIP and Internet Telephony Applications by David Slotten Tripp Lite is a Cisco Technology Developer Partner in the Cisco Technology Developer Program.
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA
Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA Liebert GXT3 is a full feature UPS providing reliable protection for IT network equipment and data centers. It is a true
Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS
Smart-UPS Advanced line interactive power protection for servers and network equipment The world s most popular network and server UPS The award-winning Smart-UPS unit from APC by Schneider Electric is
GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work
GE Consumer & Industrial Power Protection UPS Uninterruptible Power Supplies GE imagination at work For more than a century, GE has led the way with innovative technologies and groundbreaking quality initiatives
PowerGem Pro Uninterruptible Power Supply
Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA -3000VA Intelligent, Reliable UPS Protection Liebert
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
Common Power Problems & Power Protection Solutions
W H I T E P A P E R Common Power Problems & Power Protection Solutions Executive Summary All systems, from home theaters and office desktops to enterprise IT equipment in data centers, are prone to downtime,
LAP ENERGIA PARA DATACENTERS
LAP ENERGIA PARA DATACENTERS Latin American Power. CABA, Argentina. 2 UPS INDOOR Latin American Power. CABA, Argentina. ALI ELITE SERIES Line Interactive UPS Tower/19 Rack Mount Versions 19 Rack Mount
Product Snapshot. Powerware 5125 Family Uninterruptible Power System. Introducing the expanded Powerware 5125 family of UPSs.
Powerware 5125 Family Uninterruptible Power System Product Focus Powerware 5125 tower model 1000 to 2200 VA Features Protects connected equipment from common power anomalies including surges, sags, brownouts,
Galleon 6-10K Online UPS. Voltronic Power Technology Corporation
Galleon 6-10K Online UPS Voltronic Power Technology Corporation Features Galleon online UPS series delivers optimal power quality, provides superior power management, resolves utility power protection
Smart-UPS On-Line 230 V
Smart-UPS On-Line 230 V Unity output power factor single-phase, double-conversion online UPS with advanced management features A versatile UPS developed for unstable power conditions worldwide Smart-UPS
QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview
Overview The Tower UPS "G2" models are the next generation HP tower UPSs with USB support. These new UPSs are designed to provide advanced power protection (or increased uptime and data corruption avoidance)
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview
Overview The industry leading packs up to 3000 watts into a space saving 2U design. Proven Digital Signal Processor (DSP) double conversion system provides clean, reliable power protection in an energy
PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR
PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR CLASSIFICATION CLASSIFICATION ACC. TO - AEG S UPS PRODUCT PORTFOLIO - IT S APPLICATION ORIENTED USE - UPS PRODUCT
HP R/T3000 G2 Uninterruptible Power System (UPS) Overview
Overview The industry leading packs up to 3000 watts into a space saving 2U design. Proven Digital Signal Processor (DSP) double conversion system provides clean, reliable power protection in an energy
For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on
Home Sign In View Cart Order Status Search Solutions Products and Services Support Your Business Company Data Center Server Rooms Solutions for Small-Medium Data Center Large Data Centers Cloud & Co-location
NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL
NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL [email protected] / www.tuncmatik.com Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3.
APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply
APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality
USER MANUAL Online UPS 1K/2K/3K Rack
USER MANUAL EN Online UPS 1K/2K/3K Rack Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation 2
Choosing Close-Coupled IT Cooling Solutions
W H I T E P A P E R Choosing Close-Coupled IT Cooling Solutions Smart Strategies for Small to Mid-Size Data Centers Executive Summary As high-density IT equipment becomes the new normal, the amount of
Eaton 93PM UPS Efficient. Scalable. Innovative.
Product rochure 20-100 kw aton UPS fficient. Scalable. Innovative. features and benefits The aton UPS combines unprecedented and reliability with an eye-catching design. space-saving, scalable and flexible
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.
NEW APC Smart-UPS Advanced line interactive power protection for servers and network equipment. > The world s most popular network and server UPS. Award-winning Smart-UPS protects critical data by supplying
Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS
+ Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
QuickSpecs. Compaq Uninterruptible Power Systems M ODELS
M ODELS Rack-Mountable UPS Models 242704-001 242705-001 h-na 242705-003 Tower UPS Models 295372-B21 242688-001 242688-003 242688-005 T2400h-NA 242688-007 OVERVIEW Compaq UPS Products Compaq has developed
HEALTHCARE / MEDICAL SOLUTIONS
HLTHR / MDIL SOLUTIONS Healthcare/Medical Solutions Tripp Lite manufactures power protection, power supply and regulatory compliance solutions for use in hospitals and other healthcare facilities worldwide.
Dell Smart-UPS 1,500 3,000 VA
Dell Smart-UPS,00,000 VA 0 V Advanced line interactive power protection for servers and network equipment Reliable. Intelligent. Efficient. Manageable. Engineered by APC by Schneider Electric, the Dell
USER MANUAL Online UPS 1K/2K/3K
USER MANUAL EN Online UPS 1K/2K/3K Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1.1. Transportation 2 1.2. Preparation 2 1.3. Installation 2 1.4. Operation 2 1.5.
R5000 Uninterruptible Power System (UPS) Overview
Overview The innovative Minimally Switched Technology used in the HP R5000 UPS improves the performance over traditional line-interactive UPS designs while reducing the cost, weight, and size of traditional
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,
Back-UPS Pro 1300/1500 Installation and Operation
Back-UPS Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a
R5000 Uninterruptible Power System (UPS) Overview
Overview The innovative Minimally Switched Technology used in the HP R5000 UPS improves the performance over traditional lineinteractive UPS designs while reducing the cost, weight, and size of traditional
NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.
NEW APC Smart-UPS Advanced line interactive power protection for servers and network equipment. > The world s most popular network and server UPS. Award-winning Smart-UPS protects critical data by supplying
Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE
Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs EPOS (Electronic Point of Sale) Systems Emergency devices (lights/alarms) Electro-medical devices Telecommunication
Rack Power Distribution
The Rack PDU Selector is located at: www.apc.com/tools/selector/pdu Test drive a metered or switched Rack Power Distribution Rack PDU at testdrive.apc.com 132 Fairgrounds Road West Kingston, RI 02892 Phone:
Installation and Operation Back-UPS 1250, 1300, 1500
Installation and Operation Back-UPS 1250, 1300, 1500 Inventory bu001a Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with
UNINTERRUPTIBLE POWER SUPPLY (UPS)
Your Inspirations. Our Innovations. UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting Your Data CATALOGUE Revision 0 Table of Contents Table of Contents About Us - Company Profile Online UPS Professional
Top 8. Considerations for Choosing the Right Rack Power Distribution Unit to Fit Your Needs
Power design in data centers is getting substantial attention particularly by facilities and engineering personnel as organizations pursue constant improvements in reliability and energy efficiency. At
MAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply
User Manual English APC Smart-UPS SC 1000/1500 VA 110/120/230 Vac 2U Tower/Rack-Mount Uninterruptible Power Supply 990-1851C, 10/2005 Introduction The APC Uninterruptible Power Supply (UPS) is designed
How To Power A Bladecenter H Servers
Solutions Guide for IBM Data Center Architecture: IBM BladeCenter H Servers In today s high-demand enterprise environment, organizations need a reliable infrastructure to run compute-intensive applications
How To Install A Power Supply (Uplast) With A Battery Pack
APC Smart-UPS RT SURTA48XLBP/SURTA48XLBPJ External Battery Pack User Manual Introduction/Before Installation About this Manual The APC Smart-UPS RT external battery pack (SURTA48XLBP or SURTA48XLBPJ) connects
Rack Power Distribution. Worldwide
Rack Distribution Worldwide Introduction APC TM by Schneider Electric TM offers a wide array of standardized Rack Distribution Units (PDUs) designed to increase manageability and efficiency in your data
QuickSpecs. HP IP Console Switch with Virtual Media Overview
Overview HP's IP Console Switch with Virtual Media is a key component in managing the heterogeneous data center and along with the IP Viewer software allows remote access to multiple servers running various
Online UPS. PowerWalker VFI 1000R/1U
Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4.
QuickSpecs. Models HP Server Console Switches
Overview are key components for rack mount implementations (a console represents one keyboard, video monitor, and mouse (KVM) attached to a server). The family of allows multiple servers in a rack to be
Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7
Register online today for a chance to win a FREE Tripp Lite product! www.tripplite.com/warranty Owner s Manual Internet Office & BC Personal UPS Systems Not suitable for mobile applications. Important
Back-UPS 650 VA 120 V with AVR (BX650CI-LM)
Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit
Eaton 93PM UPS Efficient. Scalable. Innovative.
Product rochure 20-200 kw aton UPS fficient. Scalable. nnovative. features and benefits The aton UPS combines unprecedented and reliability with an eye-catching design. space-saving, scalable and flexible
Cisco Nexus 7000 Series Power Supply Modules
Cisco Nexus 7000 Series Power Supply Modules Product Overview The Cisco Nexus 7000 Series Power Supply Modules (Figures 1 and 2) deliver fault tolerance, high efficiency, load sharing, and hot-swappable
INTEGRATED SOLUTIONS. FREE IT Infrastructure Assessment. Tripp Lite Integrated Solutions
INTEGRATED SOLUTIONS MAXIMIZE AVAILABILITY SIMPLIFY MANAGEMENT OPTIMIZE EFFICIENCY REDUCE COSTS Tripp Lite Integrated Solutions Maximize the availability, manageability and efficiency of your equipment
RT5kVA and RT6kVA 3U Rack or Tower Uninterruptible Power Supplies Product Guide
RT5kVA and RT6kVA 3U Rack or Tower Uninterruptible Power Supplies Product Guide The RT5kVA and RT6kVA 3U Rack or Tower Uninterruptible Power Supply (UPS) offerings provide extended power protection with
Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments
Powerware 9140 Uninterruptible Power System Product Focus Superior de-centralized power protection for medium- and high-density rack environments Product Snapshot Power Rating: Nominal Input Voltage: Nominal
QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA - 12859 North America Version 5 August 22, 2008 Page 1
Overview It's getting harder to manage a data center efficiently, with rising utility bills and ever-increasing demands due to processor power and server density increases. Growing user requests mean heavier
HP R12000 and R18000 DirectFlow UPS User Guide
HP R12000 and R18000 DirectFlow UPS User Guide Abstract This document includes installation, configuration, and operation information for the HP R12000 and R18000 DirectFlow UPS. This document is for the
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
Server Technology, Inc.
Server Technology, Inc. Power Efficiency Gains by Deploying 415 VAC Power Distribution in North American Data Centers White Paper STI-100-008 2009-April-07 Headquarters Server Technology, Inc. 1040 Sandhill
User Manual 1K/2K/3K Online UPS
User Manual 1K/2K/3K Online UPS Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4. Operation...
HP Server Console Switch with Virtual Media Overview
Overview HP's Server Console Switch with Virtual Media is a key component in managing the data center. Connections for two local consoles (a console represents one keyboard, monitor and mouse) allow access
Power Commander Power Distribution Units from Wiremold/Legrand offer
Power Commander Power Distribution Units Rack Power Distribution Solutions for IT/Network Environments Power Commander Power Distribution Units from Wiremold/Legrand offer comprehensive power distribution
Series IDU/IDF. Refrigerated Air Dryer
Refrigerated ir ryer Series IU/IF The models IF1 to 11 and IU3 to 6 have been revised. For details, refer to catalog no. S30-8. Similar updating for other IF/IU models is scheduled to follow shortly. In