GLASSX crystal The glass that stores, heats and cools.
|
|
|
- Elmer Wells
- 10 years ago
- Views:
Transcription
1 GLASSX crystal The glass that stores, heats and cools.
2
3
4
5
6 The GLASSX crystal method of functioning GLASSX crystal integrates 4 system components in a functional unit: transparent heat insulation, protection from overheating, energy conversion and thermal staroge. A 3-ply insulating glass construction provides excellent heat insulation with an U-value of less than 0.5 W/m 2 K. A prismatic glass implemented in the space between the panes sun rays with an angle of incidence of more than 40 (in summer, when the sun is high in the sky). On the other hand, the winter sun passes through the sun protection at full intensity. The central element of GLASSX crystalis a heat storage module that receives and stores the solar energy and, after a time, releases it again as pleasant radiant heat. PCM (Phase Change Material) in the form of a salt hydrate is used as the storage material. The heat is stored by melting the PCM; the stored heat is released again when the PCM cools. The salt hydrate is hermetically sealed in polycarbonate containers that are painted grey to improve the absortion efficiency. On the interior side, the element is sealed by 6 mm tmepered safety glass that can be printed with any ceramic silk-screen print. Summer sun high in the sky > 40 Total reflecion of the rays Shallow winter sun < 35 Loss-free passage of the rays
7 The characteristics of GLASSX crystal Environment Use of renewable solar energy. GLASSX crystal produces clean solar heat for space heating by converting solar radiation into thermal energy. Efficiency GLASSX crystal has high efficiency because line and storage losses do not apply. This system has no threshold losses; energy is input even in case of diffuse solar radiation. Compact system Low element thickness at a good U-value of less than 0.5 W/m 2 K. All the system components - transparent heat insulation, protection from overheating, energy conversion and thermal storage - are intergrated in one element. Maintenance and service life GLASSX crystal contains neither mechanical components nor electronic controls, thus guaranteeing a long, serive-free useful lifetime as well as a high degree of dependability. User friendlyness GLASSX crystal does not require technical know-how during operation, e.g. switching from summer to winter mode. Fast and simple assembly GLASSX crystal can be installes by fassade construcors without specialized knowledge just normal insulating glass. Comfort High surface temperatures (26 C to 28 C) on the inside of the element lead to more room comfort. In winter, the inner side of GLASSX crystal functions as a solar tiled stove, giving off uniform and pleasan radiant heat, which significantly improves the thermal comfort and thus the comfort in the home. Form/ design The freely selectable format of GLASSX crystal permits it to be applied fleibly. The inner side, which can be printed individually, offers a large design latitude for architects and planners.
8 GLASSX crystal - technical data Glass 1 exterior Gap between panes 1 Glass 2 Gap between panes 2 Glass 3 Gap between panes 3 Glass 4 interior Tempered safety glass Gap between panes with prism plate and inert gas Tempered safety glass with Low-E Gap between panes with inert gas Tempered safety glass with Low-E Gap between panes with PCM-plate clear Floatglas, optional with ceramic screenprint* Element thickness mm Thickness tolerance -1/+4 mm Fold width mm Weight max. 95 kg/m² Max. surface area 6,0 m² Max. hight 3000 mm Max. width 2000 mm Heat transmission coeccicient (U-value) up to 0,48 W/m²K Light transmission for crystalline PCM 8-28 % (± 3 %) for fluid PCM % (± 4 %) Total energy transfer ratio (g-value): vertical direct irradiation for crystalline PCM 33 % (± 4 %) for fluid PCM 37 % (± 4 %) diffuse irradiation 29 % seasonal winter months for crystalline PCM 33 % for fluid PCM 35 % seasonal summer months for crystalline PCM 6 % for fluid PCM 9 % Storage capacity 1185 Wh/m² Storage temperature C * completion as safety glass The specifications U-value, light transmission and g-value are certificated by the Fraunhofer Institut für Solare Energiesysteme. 2.1 GLASSX crystal GLASSX crystal - tachnical data
9 GLASSX comfort - technical data Glass 1 exterior Gap between panes 1 Glass 2 Gap between panes 2 Glass 3 Gap between panes 3 Glass 4 interior Tempered safety glass Gap between panes with inert gas Tempered safety glass with Low-E Gap between panes with inert gas Tempered safety glass with Low-E Gap between panes with PCM-plate clear Floatglas, optional with ceramic screenprint* Element thickness mm Thickness tolerance -1/+4 mm Fold width mm Weight max. 92 kg/m² Max. surface area 6,0 m² Max. hight 3000 mm Max. width 2000 mm Heat transmission coeccicient (U-value) up to 0,48 W/m²K Light transmission for crystalline PCM 8-28 % (± 3 %) for fluid PCM % (± 4 %) Total energy transfer ratio (g-value): vertical direct irradiation for crystalline PCM 33 % (± 4 %) for fluid PCM 37 % (± 4 %) Storage capacity 1185 Wh/m² Storage temperature C * completion as safety glass The specifications U-value, light transmission and g-value are certificated by the Fraunhofer Institut für Solare Energiesysteme. 2.2 GLASSX comfort GLASSX comfort - tachnical data
10 GLASSX prism - technical data Glass 1 exterior Gap between panes 1 Glass 2 Gap between panes 2 Glass 3 interior Tempered safety glass Gap between panes with prism plate and inert gas Tempered safety glass with Low-E Gap between panes with inert gas Tempered safety glass with Low-E optional with ceramic screenprint Element thickness mm Thickness tolerance -1/+4 mm Fold width mm Weight max. 54 kg/m² Max. surface area 6,0 m² Max. hight 3000 mm Max. width 2000 mm Heat transmission coeccicient (U-value) up to 0,48 W/m²K Light transmission up to 54 % Total energy transfer ratio (g-value): vertical direct irradiation 44 % (± 5 %) diffuse irradiation 29 % seasonal winter months 41 % seasonal summer months 12 % The specifications U-value, light transmission and g-value are certificated by the Fraunhofer Institut für Solare Energiesysteme. 2.3 GLASSX prism GLASSX prism - tachnical data
11 GLASSX store - technical data Glass 1 Gap between panes 1 Glass 2 Tempered safety glass Gap between panes with PCM-plate Tempered safety glass optional with ceramic screenprint Element thickness mm Thickness tolerance -1/+4 mm Fold width mm Weight max. 58 kg/m² Max. surface area 6,0 m² Max. hight 3000 mm Max. width 2000 mm Light transmission for crystalline PCM 0-38 % (± 3 %) for fluid PCM 4-55 % (± 3 %) Total energy transfer ratio (g-value): vertical direct irradiation for crystalline PCM 33 % (± 4 %) for fluid PCM 37 % (± 4 %) Storage capacity 1185 Wh/m² Storage temperature C For interior use The specification light transmission is certificated by the Fraunhofer Institut für Solare Energiesysteme. 2.4 GLASSX store GLASSX store - tachnical data
12 Referenz GlassX prism Raumseitiges Glas mi Siebdruck Ätzton N7 Wohn - und Verwaltungsgebäude, Berlin Architekt: C.Fischer, Innenarchitekten, 2006 copyright 2007FlorianKleinefenn copyright 2007FlorianKleinefenn
13 Referenz GlassX prism Raumseitiges Glas mi Siebdruck Ätzton copyright 2007FlorianKleinefenn N7 Wohn - und Verwaltungsgebäude, Berlin Architekt: C.Fischer, Innenarchitekten, 2006 copyright 2007FlorianKleinefenn
14 Referenz GlassX crystal Hochtransparentes PCM Gläser ohne Siebdruck Marché international support Office, Kemptthal Nullenergieprojekt, Schweizer Solarpreis 2007 Architekt: Beat Kämpfen, Zürich 2007
15 Referenz GlassX crystal Hochtransparentes PCM Gläser ohne Siebdruck Marché international support Office, Kemptthal Nullenergieprojekt, Schweizer Solarpreis 2007 Architekt: Beat Kämpfen, Zürich 2007
16 Referenz GlassX crystal Anthrazit eingefärbte PCM - Behälter Raumseitiges Glas mit Siebdruck weiss Alterswohnen Domat/Ems Detailpreis 2007 Architekt: GlassX architecture, Zürich 2004
17 Referenz GlassX crystal Grau eingefärbte PCM - Behälter Raumseitiges Glas mit Siebdruck Ätzton Minergie-P Wohnüberbauung Im Bächli, Teufen I Architekt: GlassX architecture, Zürich 2007
18 Referenz GlassX crystal Anthrazit eingefärbte PCM - Behälter Raumseitiges Glas mit Siebdruck weiss Eulachhof, Oberwinterthur Nullenergiesiedlung, Schweizer Solarpreis 2007 Architekt: GlassX architecture, Zürich 2007
19 Referenz GlassX crystal Anthrazit eingefärbte PCM - Behälter Raumseitiges Glas mit Siebdruck weiss Eulachhof, Oberwinterthur Nullenergiesiedlung, Schweizer Solarpreis 2007 Architekt: GlassX architecture, Zürich 2007
20 Referenz GlassX crystal Forschungsprojekt PCM und Prismenglas PCM aus Paraffinen Solarhaus III, Ebnat Kappel Forschungsauftrag BFE: PCM - und Prismenglas Architekt: Dietrich Schwarz, 2000 Schweizer Solarpreis 2001
21 Referenz GlassX comfort hochtransparentes PCM Raumseitiges Glas ohne Siebdruck The House That Kevin Built Channel 4, ExCel, London Building Research Establishment, Watford, UK Architekt: bbm sustainable design East Sussex, 2008
22
23
24 Visit our Website. Take your time looking at our list of references and see how not only the functions, but also the aesthetics, prove our points. 2005, GlassX AG Subject to technical modifications without notice. GLASSX crystal is a registered trademark of GlassX AG Redaktion: GlassX AG Design: peyerbeer.ch Fotos: Gaston Wicky
The GLASSX crystal method of functioning.
The GLASSX crystal method of functioning. GLASSXcrystal integrates 4 system components in a functional unit: transparent heat insulation, protection from overheating, energy conversion and thermal storage.
Adaptive strategies for office spaces in the UK climate
International Conference Passive and Low Energy Cooling 631 Adaptive strategies for office spaces in the UK climate I. Gallou Environment & Energy Studies Programme, Architectural Association Graduate
Pilkington Activ. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.
Pilkington Activ The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Thermal insulation. When it comes to conservatories, we think
SELECTIVE GLAZING FOR SUN CONTROL
SUN CONTROL GLAZING SELECTIVE GLAZING FOR SUN CONTROL Sun Factor 1st level performance for direct solar energy Solar energy control Solar control coating Only if the glass is exposed to sun rays! 2nd level
Passive Solar Design and Concepts
Passive Solar Design and Concepts Daylighting 1 Passive Solar Heating Good architecture? The judicious use of south glazing coupled with appropriate shading and thermal mass. Summer Winter Passive solar
Unbeatable energy efficient glass curtain wall system
Unbeatable energy efficient glass curtain wall system CONTENT Introduction 1 System 2 World Class Engineering 4 Unit Selection 5 Energy Efficiency & Comfort 10 Maximised Installation Efficiency 12 Aesthetics
Translucent Facades. Express your creativity start planning with Rodeca. Aesthetics Functionality Efficiency
Translucent Facades Express your creativity start planning with Rodeca Aesthetics Functionality Efficiency ade by Rodeca Translucent facades Facades reflect in many ways the function of clothing. They
EN 1279-5. Insulating glass units, intended to be used in buildings and construction works
4 (#2) - 12-4, Thermally Toughened Heat and Solar Control Glass 1 (C) 3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,71/0,10/0,11 Solar energy characteristics
Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.
Self-Cleaning The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Conservatories bringing the outside in. Pilkington Activ has made
Pilkington Activ self-cleaning glass. The clear choice for your conservatory.
Self-cleaning Pilkington Activ self-cleaning glass. The clear choice for your conservatory. Pilkington Activ Range Self-cleaning and solar control glass for conservatories and orangeries. Conservatories
Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.
Double Glazing Glass Energy Saving Solutions Harris Silicones & Glass (Pvt.) Company Introduction Pioneers of Silicone Sealants in Pakistan Manufacturing in collaboration with Momentive Performance Materials
LOW-E PHOTOVOLTAIC GLASS TECHNICAL GUIDE
LOW-E GLASS TECHNICAL GUIDE SELECTIVE INFRARED RADIATION FILTER Infrared radiation coming from natural sun light can cause a heat build-up inside building; This situation leads to thermal imbalance during
FACTSHEET Assessing the Feasibility of Using Solar-Thermal Systems for Your Agricultural or Agri-Food Operation
FACTSHEET Assessing the Feasibility of Using Solar-Thermal Systems for Your Agricultural or Agri-Food Operation Solar-thermal systems collect the sun's energy and convert it into heat. This energy can
THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.
THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT. A Diagrammatic representation of the relationship between the
EN 1279-5. Insulating glass units, intended to be used in buildings and construction works
4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics
Light Architecture. Colors Sweden. Light
Light Architecture Danpalon is the complete daylighting solution offering exceptional quality of light, thermal insulation and UV protection with a rich non-industrial visual appeal. The Danpalon system
Elegance SC. Solar Control
Elegance SC Solar Control Sapa Building System Building Understanding In an age of global warming, the reduction of carbon emissions is a key factor when both selecting materials for a building and how
Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number 610.14351-R1D1. 13 January 2015
EcoPelmet Pty Ltd c/- Geoff Hesford Engineering 45 Market Street FREMANTLE WA 6160 Version: Page 2 PREPARED BY: ABN 29 001 584 612 2 Lincoln Street Lane Cove NSW 2066 Australia (PO Box 176 Lane Cove NSW
Comments on How Exterior Paints and Interior Paints Can Play Roles in Conserving Energy. For Tech Traders Inc. By H. F. Poppendiek
Comments on How Exterior Paints and Interior Paints Can Play Roles in Conserving Energy For Tech Traders Inc. By H. F. Poppendiek June 2002 GEOSCIENCE LTD 620 Marindustry Drive San Diego, California 92121
EN 1279-5. Insulating glass units, intended to be used in buildings and construction works
4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Argon (90%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics
Full credit for this chapter to Prof. Leonard Bachman of the University of Houston
Chapter 6: SOLAR GEOMETRY Full credit for this chapter to Prof. Leonard Bachman of the University of Houston SOLAR GEOMETRY AS A DETERMINING FACTOR OF HEAT GAIN, SHADING AND THE POTENTIAL OF DAYLIGHT PENETRATION...
Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: 86-531-8235 5576 Fax: 86-531-82357911 Http://www.vicot.com.
Vicot Solar Air Conditioning V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: 86-531-8235 5576 Fax: 86-531-82357911 Http://www.vicot.com.cn Cooling, heating, and domestic hot water. Return on investment
Selecting Energy Efficient New Windows in Georgia
Selecting Energy Efficient New Windows in Georgia www.efficientwindows.org January 016 ENERGY STAR Zones 1. Meet the Energy Code & Look for the ENERGY STAR Windows must comply with your local energy code.
Optimum Solar Orientation: Miami, Florida
Optimum Solar Orientation: Miami, Florida The orientation of architecture in relation to the sun is likely the most significant connection that we can make to place in regards to energy efficiency. In
Constructions Database User Guide <Virtual Environment> 5.9
Constructions Database User Guide 5.9 Page 1 of 35 Contents 1. Introduction...3 2. Units...4 3. Main Dialogue Project Constructions...5 3.1. Outline...5 3.2. Construction Classes
Selecting Energy Efficient New Windows in Arizona
Selecting Energy Efficient New Windows in Arizona www.efficientwindows.org January 016 ENERGY STAR Zones 1. Meet the Energy Code & Look for the ENERGY STAR Windows must comply with your local energy code.
ResearcH JournaL 2009 / VOL 01.01. www.perkinswill.com
ResearcH JournaL 2009 / VOL 01.01 www.perkinswill.com PERKINS+WILL RESEARCH JOURNAL / VOL 01.01 05. CONTEXT BASED DESIGN OF DOUBLE SKIN FACADES Climatic Considerations During the Design Process Ajla Aksamija,
School in Schwanenstadt, Austria
School in Schwanenstadt, Austria 1. INTRODUCTION PROJECT SUMMARY - building period 1960s - numerous expansions SPECIAL FEATURES - Renovation to meet Passive House Standard - decentralized ventilation system
SKY-TILE SKY-TILE. Daylight Consultants web: www.espaciosolar.com blog: espaciosolar.blogspot.com. Bioclimatic Modular Skylights
DEPLOSUN DEPLOSUN is a modular glazing system that has a selective solar factor in relation with solar possition.this system is to be used in horizontal skylights. It is composed by a tempered T 6mm. glass
ENERGY SAVING WINDOW FILMS S LAR CONTROL
ENERGY SAVING WINDOW FILMS S LAR CONTROL Overview Managing Solar Heat Gain - Solar Control Window Film With an ever increasing need to achieve outstanding energy efficiency within buildings without compromising
Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems
Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency
The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows
by The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows In Alliance with OCCUPANT COMFORT All of the windows above have the same exterior tint of glass. Why such a
Selecting Energy Efficient Replacement Windows in Nevada
Selecting Energy Efficient Replacement Windows in Nevada www.efficientwindows.org January 06 STAR Zones. Meet the Energy Code & Look for the STAR Windows must comply with your local energy code. Windows
Solar Energy Systems
Solar Energy Systems Energy Needs Today s global demand for energy is approximately 15 terawatts and is growing rapidly Much of the U.S. energy needs are now satisfied from petroleum (heating, cooling,
ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests
ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests DesignBuilder Version 1.2.0 (incorporating EnergyPlus version 1.3.0) - June 2006 1.0 Purpose The ANSI/ASHRAE Standard 140-2004
Pilkington Activ self-cleaning glass. The clear choice for your conservatory.
Pilkington Activ self-cleaning glass. The clear choice for your conservatory. The Pilkington Activ Range Self-cleaning and solar control glass for conservatories and orangeries. Conservatories bringing
New technical solutions for energy efficient buildings
- New technical solutions for energy efficient buildings State of the Art Report Energy efficient building design Authors: Heimo Staller, Angelika Tisch, IFZ Oct. 2010 Background In the building sector
Solar Heating Basics. 2007 Page 1. a lot on the shape, colour, and texture of the surrounding
2007 Page 1 Solar Heating Basics Reflected radiation is solar energy received by collectorsfrom adjacent surfaces of the building or ground. It depends a lot on the shape, colour, and texture of the surrounding
DEPLOSUN REFLECTORS. Carrer dels Vergós, 11 08017 Barcelona Spain Tel: (+34) 934.090.359 Fx: (+34) 934.090.358 info@espaciosolar.
DEPLOSUN REFLECTORS DEPLOSUN REFLECTORS DEPLOSUN REFLECTORS is an innovative reflector system which captures the sun rays in the upper part of the atria and redirects them downwards, increasing daylight
Selecting Energy Efficient New Windows in Texas
Selecting Energy Efficient New Windows in Texas www.efficientwindows.org January 06 Zones. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are certified
THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel
THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING R.M.J. Bokel Department of Architecture, Delft Technical University, Delft, The Netherlands,
Design qualification and type approval of PV modules
Design qualification and type approval of PV modules TÜV Immissionsschutz und Energiesysteme GmbH Test Centre for Energy technologies May 2003 Design qualification and type approval of PV-modules in accordance
Energy Efficiency in Buildings
Energy Efficiency in Buildings Supplemental Guide to SANS 10400-XA & SANS 204 V. 3.0 Registered to: The Drawing Studio Image: digitalart / FreeDigitalPhotos.net Report Date: 26 August 2014 Practice Name:
Solar Energy. Solar Energy range. NSG TEC Pilkington Microwhite Pilkington Optiwhite Pilkington Sunplus
Solar Energy Solar Energy range NSG TEC Pilkington Microwhite Pilkington Optiwhite Pilkington Sunplus Moving from hydrocarbon dependency to renewable energy The use of solar energy glass and the NSG Group
Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi
Climate and Energy Responsive Housing in Continental Climates The Suitability of Passive Houses for Iran's Dry and Cold Climate Farshad Nasrollahi Table of Contents Abstract German Abstract Introduction
Perspective-Dependent Color-Changing Roofing Sheets
Perspective-Dependent Color-Changing Roofing Sheets Anthony Cartwright, Joseph Karas, Steven McCarthy, Brian Paige Saint Gobain Student Design Competition, 3/24/2010 Project Summary: Direct natural sunlight
Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro
Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro Dept. Building Environment Science &Technologies Politecnico di Milano Italy Research funded
Case Study 13 Schools of Architecture and Design, Wellington tertiary education institute, New Zealand
Case Study Schools of Architecture and Design, Wellington tertiary education institute, New Zealand Winter Summer daylight intermediate, intermediate, climate temperate, oceanic altitude m heating degree
Opening the Bonnet. Prof Darren Woolf WYSINWYG 1
Opening the Bonnet Prof Darren Woolf WYSINWYG 1 WYSINWYG What You See Is NOT What You Get: Looking inside the Pandora s Box Prof Darren Woolf WYSINWYG 2 WYSIWYG implies a user interface that allows the
Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels. W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd.
Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd. 1 The Kingspan Group Energy independent buildings for a sustainable
Sustainable water heating solutions through solar systems
VIESMANN Sustainable water heating solutions through solar systems Murat Aydemir Managing Director Viessmann Middle East FZE Viessmann is a Registered Provider with The American Institute of Architects
Significance of Glazing Thermal Conductivity for MAC Indirect Emissions and EV Battery Performance
Significance of Glazing Thermal Conductivity for MAC Indirect Emissions and EV Battery Performance Steve Gasworth and Triloka Tankala SABIC Innovative Plastics [email protected] [email protected]
Solar Thermal Systems
Solar Thermal Systems Design and Applications in the UAE Murat Aydemir Viessmann Middle East FZE General Manager (M.Sc. Mech.Eng., ASHRAE) Dubai Knowledge Village Congress Centre, Dubai 20.4.2009 Viessmann
PYRAN PYRANOVA. Special-purpose glass products for fire resistant glazing
PYRAN PYRANOVA Special-purpose glass products for fire resistant glazing 2 SCHOTT is an international technology group with more than 125 years of experience in the areas of specialty glasses and materials
Residential Windows, 3 rd edition Corrected index 1
Residential Windows, 3 rd edition Corrected index 1 A absorptance definition, 78 determinants of, 78 79 energy performance and, 78 tinted glass, 84 acoustical properties of windows, 60 61 acrylic glazing
CHAPTER 6: WINDOWS AND DOORS
Chapter 6: Windows and Doors 89 CHAPTER 6: WINDOWS AND DOORS Windows and doors connect the interior of a house to the outdoors, provide ventilation and daylight, and are important aesthetic elements. Windows
Exemplary Retrofitting of an Old School in Stuttgart - EROS -
Exemplary Retrofitting of an Old School in Stuttgart - EROS - City of Stuttgart, Summary The objective of the project was to demonstrate the potentials of a retrofitting process for a typical school in
FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS
FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS 1 Ralf Lindberg, Professor Minna Korpi, M.Sc. Juha Vinha, Dr.Tech. June 11, 2008 Department of Civil Engineering, Tampere University of Technology 2 BACKGROUND
Selecting Energy Efficient New Windows in Florida
Selecting Energy Efficient New Windows in Florida www.efficientwindows.org January 06 Zones. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are certified
Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...
Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system
Windows are one of the most important components of a
design concepts Arjun Kamal MAKING BETTER INDOOR ENVIRONMENTS WITH ENERGY-EFFICIENT WINDOW DESIGN An insight into the various technologies used for constructing windows, and an attempt at understanding
Building Integrated Photovoltaic (BIPV)
Building Integrated Photovoltaic (BIPV) Jan-Willem Tolkamp, International Account Manager BIPV Solar power on buildings' conference, 20th October 2010 see it. feel it Index 1. From PV to BIPV 2. The BIPV
Impact-Resistant Windows and Sliding Glass Doors
Impact-Resistant Windows and Sliding Glass Doors Make Your Home A SafeHarbor. SafeHarbor Impact-Resistant Windows and Sliding Glass Doors are designed to look like traditional windows and doors, but they
Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015
www.zebra2020.eu Delivering on innovation and market uptake. Best-in-cases of nzeb Ramon Pascual Bucharest May 8th, 2015 Outline nzeb Database Best in cases of nzeb Climates in Europe Preliminary results
Residential HVAC System Sizing
Residential HVAC System Sizing William P. Goss University of Massachusetts, Amherst, Massachusetts, USA Corresponding email: [email protected] SUMMARY Heating, ventilating and air-conditioning (HVAC)
Fire-Rated Glass and Glazing START
Fire-Rated Glass and Glazing START www.pilkington.com/fire Fire-Rated Glass and Glazing Pilkington Fire Protection Glass North America 946 Kane Street, Suite A Toledo, OH 43612 Provider Number: J200 Course
Icopal Eco-Activ Product Range Overview. Noxite. Dalite Rooflights. Monarfloor Acoustics. ICOSUN Console. Sun-Activ. Therm X
Icopal Eco-Activ Product Range Overview Noxite Monarfloor Acoustics ICOSUN Console Therm X Dalite Rooflights Sun-Activ Icopal Eco-Activ Product Range The highly innovative Eco-Activ range provides architects
Architectural integration of solar thermal collectors into the building envelope
Architectural integration of solar thermal collectors into the building envelope Charlotta Isaksson, Thomas Müller, Irene Bergmann AEE - Institute for Sustainable Technologies (AEE INTEC) A-8200 Gleisdorf,
HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.
HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET. AFFORDABLE SOLUTIONS FROM AMERISTAR. We know that heating and cooling systems can be a major investment for homeowners. Our goal is
What is Solar Control?
A better environment inside and out. Solar, Safety and Security Window Films: Tech Bulletin Understanding Solar Performance Solar Gard solar control window films use advanced technology to benefit consumers
In the Fall 2002 issue of HHE News I examined
Choosing Replacement Windows 1 For Your Home Mark Pierce In the Fall 2002 issue of HHE News I examined reasons for, and against, replacing older windows with new, energy efficient windows. That article
Condensing Boiler Efficiency
Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2
Solar Power at Vernier Software & Technology
Solar Power at Vernier Software & Technology Having an eco-friendly business is important to Vernier. Towards that end, we have recently completed a two-phase project to add solar panels to our building
BER Assessors Dwellings Technical Bulletin
BER Assessors Dwellings Technical Bulletin Issue No. 3/11 May 2011 Contents: 1 Window defaults in DEAP and use of DEAP Table 6a... 2 2 Solar Space Heating Systems in DEAP... 4 3 Storage and direct electric
Heat-treated Glass. GUARDIAN A Company of Vision PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS
Heat-treated Heat-treated Glass Glass Heat-treated Glass Heat-treated Heat-treated Glass Glass REFLECTIVE GLASS LAMINATED GLASS TEMPERED GLASS FLOAT GLASS MIRRORS LOW-E GLASS SUNGUARD PATTERNED GLASS HORTICULTURAL
Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving
346 2nd PALENC Conference and 28th AIVC Conference on Building Low Energy Cooling and Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving S. Ferrari Politecnico
Sensors for Air-conditioning in Automobiles
Sensors for Air-conditioning in Automobiles www.epcos.com Contents...3 1. Evaporator sensors...3 2. Integral sensors...4 3. Solar sensors...4 4. Icing protection switches...5 5. External temperature sensors...5
Laserwelding of plastics Ir. Luc Janssen 2008
3D Laserwelding page 1 of 12 Laserwelding of plastics Ir. Luc Janssen 2008 1 Laserwelding - How it works Laserwelding is a very versatile process and is suitable for both small series and massproduction.
How To Build A Solar Energised Power Plant
Project Title Solar Energised Power Plant Project Description In recent years energy crisis has become one of the most talked about issues around the world. Especially in the developing countries, the
EN 1279-5. NPD Reaction to fire. NPD External fire behaviour. NPD Bullet resistance. NPD Explosion resistance. NPD Burglar resistance (EN 356)
4 (# 2) - 12-33.1, Heat Control Glass (Low-E #2) + Argon (90%) + Pendulum body impact resistance - 12-2 (B) 2 4-12 - 33.1 32 (-1; -3) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection
COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS -
pcoolingandheating COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS - Bjarne W. Olesen, Ph.D. D. F. Liedelt "Velta" Summary Due to intensive use of
1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
1/9/13 By Brett T. Fagan, P.E. Presented by Marie Horan, P.E. Building Diagnostics, Inc. Building Diagnostics Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
SENSITIVITY STUDY FOR ARCHITECTURAL DESIGN STRATEGIES OF OFFICE BUILDINGS IN CENTRAL CHILE: EFFECTIVENESS OF NOCTURNAL VENTILATION.
SENSITIVITY STUDY FOR ARCHITECTURAL DESIGN STRATEGIES OF OFFICE BUILDINGS IN CENTRAL CHILE: EFFECTIVENESS OF NOCTURNAL VENTILATION. Waldo Bustamante *1, Felipe Encinas 2 and Francisco Sánchez de la Flor
SOLAR ENERGY How much strikes the earth? How much can my building get? When is it too much?
SOLAR ENERGY How much strikes the earth? How much can my building get? When is it too much? The sun: friend of foe? Drawing by Le Corbusier ENGS 44 Sustainable Design Benoit Cushman-Roisin 14 April 2015
Solar shading for low energy buildings
Solar shading for low energy buildings FEBRUARY 2012 Edition 1 How shutters and blinds reduce the energy needs of buildings and improve their thermal and visual comfort MEMBERS OF THE ES-SO TECHNICAL COMMITTEE
NANSULATE NANOTECHNOLOGY BASED SOLUTIONS TO REDUCE HEAT LOSS THROUGH WINDOWS
NANSULATE NANOTECHNOLOGY BASED SOLUTIONS TO REDUCE HEAT LOSS THROUGH WINDOWS NANSULATE ENERGY PROTECT INSULATION AND PROTECTIVE COATING The science of nanotechnology is behind the innovation of Nansulate
ROTEX gas hybrid heat pump. A strong team.
ROTEX gas hybrid heat pump A strong team. The new ROTEX HPU hybrid gas hybrid heat pump always selects the most favourable heating mode automatically. For a long time the general opinion was that a heat
Humid Air. Water vapor in air. Trace Glasses 1% Argon (A) Water vapor (H 2
Humid Air Water vapor in air Oxygen 21% Trace Glasses 1% Argon (A) Water vapor (H 2 O) Carbon dioxide (CO 2 ) Neon (Ne) Helium (He) Krypton (Kr) Hydrogen (H) Ozone (O 3 ) Nitrogen 78% Humid Air Water vapor
AIRCONDITIONING Cooling Loads Calculations
Calculations -1- AIRCONDITIONING Cooling s Calculations Employer : 4M SA Project Location : ASHRAE Office Room : Example from ASHRAE 2013 Handbook - Fundamentals : Chapter 18, Single Room Example (p. 18.37)
Heat Transfer. Energy from the Sun. Introduction
Introduction The sun rises in the east and sets in the west, but its exact path changes over the course of the year, which causes the seasons. In order to use the sun s energy in a building, we need to
Energy efficiency of buildings - holistic approach in calculation methods and evaluation
Energy Efficiency - made in Germany Energy efficiency of buildings - holistic approach in calculation methods and evaluation Martin Kusic www.efficiency-from-germany.info Contents DIN V 18599 Holistic
Multi-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION 3.1 Purpose of Thermal Load Estimation 3.2 Heating Load versus Cooling Load 3.3 Critical Conditions for Design 3.4 Manual versus Computer Calculations 3.5 Heating
Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:
PASSIVE Solar Design Solar Homes Catch the Sun Are you planning a new house? Discover how you can apply solar architecture principles to: keep your heating bills to a minimum enjoy the comfort of a warm
EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010
EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a