Radio Controls Manual Protean Series
|
|
|
- Nathaniel Hamilton
- 10 years ago
- Views:
Transcription
1 Radio Controls Manual Protean Series 701P PROTEAN RADIO CONTROLS MANUAL 1
2 Conductix Incorporated The technical data and images which appear in this manual are for informational purposes only. NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE CREATED BY THE DESCRIPTIONS AND DEPICTIONS OF THE PRODUCTS SHOWN IN THIS MANUAL. Conductix makes no warranty (and assumes no liability) as to function of equipment or operation of systems built according to customer design or of the ability of any of its products to interface, operate or function with any portions of customer systems not provided by Conductix. Seller agrees to repair or exchange the goods sold hereunder necessitated by reason of defective workmanship and material discovered and reported to Seller within one year after shipment of such goods to Buyer. Except where the nature of the defect is such that it is appropriate, in Seller s judgment, to effect repairs on site, Seller s obligation hereunder to remedy defects shall be limited to repairing or replacing (at Seller s option) FOB point of original shipment by Seller, any part returned to Seller at the risk and cost of Buyer. Defective parts replaced by Seller shall become the property of Seller. Seller shall only be obligated to make such repair or replacement if the goods have been used by Buyer only in service recommended by Seller and altered only as authorized by Seller. Seller is not responsible for defects which arise from improper installation, neglect, or improper use or from normal wear and tear. Additionally, Seller s obligation shall be limited by the manufacturer s warranty (and is not further warranted by Seller) for all parts procured from others according to published data, specifications or performance information not designed by or for Seller. Seller further agrees to replace or at Seller s option to provide a refund of the sales price of any goods that do not conform to applicable specifications or which differ from that agreed to be supplied which non-conformity is discovered and forthwith reported to Seller within thirty (30) days after shipment to the Buyer. Seller s obligation to replace or refund the purchase price for non-conforming goods shall arise once Buyer returns such goods FOB point of original shipment by Seller at the risk and cost of Buyer. Goods replaced by Seller shall become the property of Seller. There is no guarantee or warranty as to anything made or sold by Seller, or any services performed, except as to title and freedom from encumbrances and, except as herein expressly stated and particularly, and without limiting the foregoing, there is no guarantee or warranty, express or implied, of merchantability or of fitness for any particular purpose or against claim of infringement or the like. Seller makes no warranty (and assumes no liability) as to function of equipment or operation of systems built to Buyer s design or of the ability of any goods to interface, operate or function with any portions of Buyer s system not provided by Seller. Seller s liability on any claim, whether in contract, tort (including negligence), or otherwise, for any loss or damage arising out of, connected with, or resulting from the manufacture, sale, delivery, resale, repair, replacement or use of any products or services shall in no case exceed the price paid for the product or services or any part thereof which give rise to the claim. In no event shall Seller be liable for consequential, special, incidental or other damages, nor shall Seller be liable in respect of personal injury or damage to property not the subject matter hereof unless attributable to gross misconduct of Seller, which shall mean an act or omission by Seller demonstrating reckless disregard of the foreseeable consequences thereof. Seller is not responsible for incorrect choice of models or where products are used in excess of their rated and recommended capacities and design functions or under abnormal conditions. Seller assumes no liability for loss of time, damage or injuries to property or persons resulting from the use of Seller s products. Buyer shall hold Seller harmless from all liability, claims, suits and expenses in connection with loss or damage resulting from operation of products or utilization of services, respectively, of Seller and shall defend any suit or action which might arise there from in Buyer s name - provided that Seller shall have the right to elect to defend any such suit or action for the account of Buyer. The foregoing shall be the exclusive remedies of the Buyer and all persons and entitles claiming through the Buyer. 2 PROTEAN RADIO CONTROLS MANUAL 701P
3 INDEX Disclaimer/General Warranty 1.0 Radio Warranty 1.1 Warranty 1.2 Warranty Period 1.3 Warranty Service 1.4 Excluded Parts 1.5 Remarks 2.0 Safety Considerations 2.1 Symbols 2.2 Warnings 3.0 Standard Components 3.1 Receiver (RX) 3.2 Transmitter (TX) 4.0 Installation Procedure 4.1 General Procedure 4.2 Receiver Setup Power Supply Selection R0 N.O./N.C. Configuration 4.3 Receiver Installation 4.4 Remote Setting 4.5 Transmitter Setup 5.0 Operation 5.1 General Precautions 5.2 Emergency Procedure 6.0 Basic Troubleshooting and Maintenance 6.1 General Precautions 6.2 General Error Codes and Resolution 6.3 Change of Fuse Change of Fuse DC Type 6.4 Change of Frequency/Crystal 7.0 Function Settings 8.0 Specifications 8.1 General 8.2 Transmitter 8.3 Receiver 701P PROTEAN RADIO CONTROLS MANUAL 3
4 1.1 Warranty 1.0 Radio Warranty Conductix-Wampfler guarantees that this equipment meets its published specifications at the time of shipment from the factory. This equipment will perform as described if installed properly. However, Conductix-Wampfler cannot guarantee that operation of remote control system is absolutely errorfree, or without interruption. 1.2 Warranty Period This equipment is warranted against defects in materials and workmanship for a period of one (1) year from the date of shipment. During the warranty period, Conductix-Wampfler is responsible for necessary repairs/ replacement as long as the product can be proven defective. 1.3 Warranty Service For warranty service or repair, this equipment must be returned to Conductix-Wampfler. Customer is responsible for shipping charges to Conductix- Wampfler. Conductix-Wampfler s warranty covers only parts and factory labor. No on site in and out charges are covered under this warranty. 1.4 Excluded Parts This warranty does not include consumable parts such as joysticks, batteries, fuses, buttons, and relays. Also, this warranty does not cover defects caused by improper installation, improper/insufficient maintenance, unauthorized modification, improper operation, ignorance of environmental specifications, and/or improper software/interfacing. 1.5 Remarks No other warranty is expressed or implied, except for the above mentioned. The remedies provided herein are the buyers sole and exclusive remedies. Conductix-Wampfler shall not be liable for any direct/indirect, special, incidental, or consequential damage. Consult Conductix-Wampfler general warranty for further information. 2.1 Symbols Safety Considerations: 2.0 Safety Considerations Check input voltage BEFORE wiring this Protean Unit. Insufficient or overvoltage WILL damage unit and VOID Warranty. The default value for AC units is 110v + 10% (99 to 121 VAC). For DC units, the voltage should be Volts. This product and related documentation must be reviewed for familiarization with safety markings and instructions before operation. This product requires strict adherence to instructions in order to ensure operational safety Safety Symbols The following symbols may be found on the remote control or throughout the remote control documentation. Their purpose is to alert you to potentially dangerous situations. Refer To Manual When the product is marked with this symbol refer to the instruction manual for additional information. High Voltage Indicates presence of hazardous voltage. Unsafe practice could result in severe personal injury. Protective Earth Ground Indicates protective earth terminal 4 PROTEAN RADIO CONTROLS MANUAL 701P
5 2.0 Safety Considerations 2.1 Symbols continued Warning Denotes hazard. Included text will give proper instructions. Failure to follow instructions could result in severe personal injury and/or property damage. Caution Denotes hazard. Included text will give proper instructions. Failure to follow instructions could result in minor personal injury and/or property damage. 2.2 Warnings 1. Read this manual carefully before operating and installing this product. 2. Due to the complex nature of equipment, it is necessary to read the entire manual before installation. 3. Only authorized personnel should service this equipment. Unauthorized work on this unit will void the warranty. 4. This manual is for reference only; please call your distributor or Conductix-Wampfler if further assistance is required. 5. The equipment has been tested for correct operation before delivery from the factory. However, it must not be used in critical or hazardous operation where incorrect operation may cause personal injury or equipment damage. 6. After daily operation, please shut off main power in crane and the power to the receiver. 7. Transmitter should be placed in a safe place when not in use to avoid accidental pressing of buttons. 8. The crane should be equipped with mainline contactor, limit switches, and other required safety devices as dictated by CMAA, OSHA, or all other applicable governing regulations. 9. The GND (ground) of receiver must be connected to ground of machine, or electrical shock can occur. 10. Do not use this device during electrical storms or under conditions of electrical interference. 11. Ensure transmitter batteries are in good condition and power for receiver is correct. 12. Installation and maintenance should be done only while the machine s main power and receiver s power are off and locked out to prevent electrical shock. 13. Contents of the manual may be amended by the manufacturer without notice. 701P PROTEAN RADIO CONTROLS MANUAL 5
6 3.0 Standard Components A standard full set of Protean Radio Control consists of: 700PRO4, 700PRO6, 700PRO8, 700PRO6HT and 700PROL8B Kits include a single (1) transmitter 700PRO4D, 700PRO6D, 700PRO8D, 700PRO6DHT and 700PROL8BD Kits include two (2) transmitters. NOTE: Upon receipt of the radio kit, please identify and verify the correct number of transmitters have been included. 3.1 Receiver Model No. Receiver Part No. 700PRO4 701P PRO4-DC 701P0040-DC 700PRO6 701P PRO6-DC 701P0060-DC 700PRO6HT 701PROL6B-RX 700PRO6HT-DC 701PROL6BDC-RX 700PRO8 701P PRO8-DC 701P0080-DC 700PROL8B 701P PROL8B-DC 701P0080-DC 3.2 Transmitter Style Model Transmitter Part No. A 4 Button 701P0004 B 4 Button HT 701PROL6B-TX A 6 Button 701P0006 B 6 Button L8B 701L8001 A 8 Button 701P0008 Style A Style B 6 PROTEAN RADIO CONTROLS MANUAL 701P
7 4.1 General Precautions 4.0 Installation Procedures 1. Observe all safety precautions when climbing or working on the machine. 2. Turn off the main power source of cranes before installation to avoid electric shock. Lockout/Tagout the main power source. 3. Receiver must be installed as to not touch any part of the machine or structure during the operation, except for mounting provisions. 4. The receiver must be fastened securely via shock-proof mount provided. 5. Before installation, inspect the crane s safety devices and make sure everything is in proper working condition. 6. To avoid any interference, the receiver must be located away from motors, frequency drives, and power cables (shown on page 7). 7. Coil suppressors must be installed on all contactor coils and relay coils where an inductive load may damage the radios relay contacts. Conductix-Wampfler recommends RC type suppressors Conductix-Wampfler Parts 103KVFCC1 with wire leads or 103KVFCC2 with bare metal leads. 4.2 Receiver Preparation Power Supply There are two types (DC and AC) available for the Protean: DC Type: Input Voltage: 12~24VDC Relay contact: 10A-36VDC AC Type: (4 different transformers: 24/48V, 48/110V, 110/220V, 220/380V): The voltage selection jumper is: Power Supply Continued 1. Locate the Hi/Low jumper to the lower left of the transformer. 2. Place the jumper connecting the two pins to enable the correct transformer setting as shown in the chart above. NOTE: The Default transformer is the 48/110V version. Please contact your distributor for other options and lead-times R0 Open/Closed Setup Transformer LO HI AC 24/48V 24V 48V AC 48/110V 48V 110V AC 110/220V 110V 220V AC 220/380V 220V 380V The Protean series provides two different outputs: NO and NC. The NO is the default setting. If an NC output is necessary, please remove the No. 8 wire (R0/Start) from the connector and insert it into No. 10. Procedure: #8 Pin Remove it Push In 701P PROTEAN RADIO CONTROLS MANUAL 7
8 4.0 Installation Procedures Procedure Continued Step 3 #10 Pin Step 4 Reconnect it to #10 Pin Lift Up 4.3 Receiver Installation 1. Turn off main power to the machine. 2. Locate a proper place for the receiver. (See diagram below.) a. Select a stable place free from electrical noise, vibration, excessive heat, etc. b. Select a location that is visible from the operation location. c. Select a location at least 3 feet away from motors, relays power cables, and frequency converters. d. Keep away from high voltage wiring and devices. e. The receiver box must be at least 1.5 (4cm) away from other obstacles. 3. Drill four (4) 6mm holes for the receiver mounting the unit with the included hardware. 4. Connect wire to the control circuit of the machine according to the wiring diagram of the receiver (shown in Section 4.3.1). 5. Secure the cable between the receiver and the machine so that the cable sheath will not wear due to vibration. 6. Complete Section 4.5 and test every function of the radio control making sure all motions are correct. 7. Secure the cover making sure not to pinch any wires between the case and the lid. 8. This completes the receiver installation. 8 PROTEAN RADIO CONTROLS MANUAL 701P
9 4.0 Installation Procedures Radio Schematics AC Models 4 Button Protean 6 Button Protean 8 Button Protean & 6 Button L8B 4 Button Protean HT 701P PROTEAN RADIO CONTROLS MANUAL 9
10 4.0 Installation Procedures DC Models 4 Button Protean 6 Button Protean 8 Button Protean & 6 Button L8B 4 Button Protean HT 10 PROTEAN RADIO CONTROLS MANUAL 701P
11 4.0 Installation Procedures 4.4 Remote Setting Remote setting allows you to pair the new TX and RX if either of them becomes damaged. In order for the radios to work the TX & RX must have the same ID codes and frequency. Using remote setting will set both the TX and RX to have the same ID codes Please ensure the following conditions are met before attempting the remote setting procedure. (a) Both TX and RX are of the SAME model and frequency. (b) Place the transmitter as close as possible to the receiver to avoid any interference. (c) Turn off the RX power for at least 10 seconds and then turn it on again. (d) Complete the Remote Setting within 4 minutes after turning on the RX. The RX will NOT accept the remote setting signal after 4 minutes time has elapsed Remote Setting Instructions: 1. Depress the transmitter STOP or EMS pushbutton. 2. Press DOWN pushbutton and hold it. 3. Press UP pushbutton (4) times and release STOP or EMS & DOWN pushbuttons when the red light flashes. 4. Start the system per General Operation (Section 5.0). 1. Press and hold the STOP/EMS pushbutton 2. Press and hold the DOWN pushbutton 3. Press the UP push button 4 times * NOTE: On HT Model (2 speed only depress to first indent for steps 2 & 3) ATTENTION: l In case the remote setting procedure fails, repeat the instructions above within 4 minutes. l The remote setting procedure will update the ID code only. It will not change function settings. l All same model systems on the same frequency will be paired with the transmitters ID code within the operating distance. 701P PROTEAN RADIO CONTROLS MANUAL 11
12 4.4.3 Remote setting precautions. 4.0 Installation Procedures If a receiver on CH1 and other receivers, for example, on CH2 and CH3 are on the same power line controlled by a switch, such as different hoists on the same crane or rail, special care must be taken. When on CH1 receiver is turned off for the required 10 seconds and then turned on the ID registration, the CH2 and CH3 receivers would be switched on simultaneously and might receive the ID registration signal from the CH1 transmitter. To avoid this, please observe the following: a) The CH2 and CH3 receivers must be at least 20 meters away from the CH1 transmitter it is being used to pair with the CH1 receiver; otherwise the CH2 and CH3 receivers may pair with the CH1 transmitter. In case this happens, switch off the receiver which incorrectly paired for at least 10 seconds, then turn it on again, and use the correct transmitter to pair with it within 4 minutes. Or, switch off the receiver and directly pair the two using the copier to read the data from the correct transmitter and then write to the receiver. Please refer to the Copier User s Manual. On the same power line receiver (CH2) The transmitter on CH1 must be at least 20 meters away from receiver on CH2 receiver (CH1) The CH1 transmitter must be as close to the CH1 receiver as possible. This can exceed 20 meters at some work sites. receiver (CH1) The transmitter on CH1 must be at least 20 meters away from receiver on CH3 transmitter (CH1) b) Because receivers do not accept an ID registration past 4 minutes after application of power to the receiver, or after the MAIN relay is energized, the best way to avoid incorrect programming of other receivers is to press START on the CH2 and CH3 transmitters to energize the MAIN relay in the CH2 and CH3 receivers, then use the CH1 transmitter to complete ID code registration within 4 minutes of switching on the receiver. 4.5 Transmitter Setup Two (2) AA sized alkaline batteries are required for the TX. The LED will flash GREEN when the battery power is sufficient. The LED will flash RED when the battery power is low. NOTES: 1. The operating distance will shorten when the batteries are low. 2. Replace with new batteries when battery power is low. 3. Re-chargeable batteries are NOT recommended, use only Alkaline batteries. 12 PROTEAN RADIO CONTROLS MANUAL 701P
13 5.0 General Operation 5.1 Standard Operation 1. Turn on the main power switch of the equipment. 2. Install two (2) AA sized alkaline batteries in the transmitter. 3. Press the START/R0 pushbutton or turn the key clockwise to the start position to turn on the main relay inside receiver. 4. Operate normally according to the function settings. 5. Please perform the following procedure when done operating: a. Press STOP or EMS pushbutton. b. Place the transmitter in safe storage location. 6. Turn off the main power switch to the equipment. 5.2 Emergency Operation In case of any emergency please: 1. Press STOP pushbutton or EMS Button on the HT & L8B Models. 2. Switch off the main power of crane. If the problem persists contact your local distributor for service. 6.0 LED MALFUNCTION ALERT 6.1 General Precautions 6.0 LED Malfunction Alert Daily inspection is important and will ensure safe operation. Inspection should include testing the emergency stop and other safety devices and functions. If there is any doubt, operation must be stopped immediately and problems must be corrected before operation is resumed. 6.2 General Error Codes and Resolutions 1. Red LED flashing quickly (every 0.2 sec) when any pushbutton is pressed. Possible Problems: (a) One of the pushbuttons is jammed. (b) The system is not properly powered according to the instructions. *If a problem is found, please contact your local distributor for repair. 2. TX LED flashes slowly (every 0.5 sec). The TX memory is defective. Contact the distributor for repair. 3. RX Error LED flashes slowly (every 0.5 sec). The RX memory is defective. Contact the distributor for repair. NOTE: The receiver error LED is located on the inside of the receiver, observe the appropriate precautions when opening the unit. 701P PROTEAN RADIO CONTROLS MANUAL 13
14 6.0 LED Malfunction Alert 6.3 Change of Fuse (F1 thru F4) Depress the fuse cover and turn counter-clockwise with a flat screwdriver to open up the fuse cover. Remove the old fuse and insert a new fuse into the cover first. Place this fuse along with cover into the fuse holder base. Depress the fuse cover and turn clockwise with flat screwdriver. Legend: F= Fuse F3 F5 Jumper Wires F2 F1 F4 (AC Type) Relay Board Reference: Relay board shown above is for 700PRO8 (DC Type) Relay Board Reference: Relay board shown above is for 700PRO8-DC Change of fuse DC Type. Unplug the yellow fuse F5 (20A) and replace with a new one. Ref Fuse # F1 F2 F3 F4 F5 Size.5A.5A 10A 1.5A 20A Part Number 701C C D D P PROTEAN RADIO CONTROLS MANUAL 701P
15 6.4 Change of Frequency/Crystal 6.0 LED Malfunction Alert The frequency of Protean system can be simply changed by replacing the correspondent crystal frequency in both the TX and RX. Please consult factory for further details. Internal Antenna Crystal Crystal Transmitter Circuit Board (Protean 4, 6, & 8 Button) Transmitter Circuit Board (Protean HT & L8 Models) Crystal Receiver Circuit Board (All Models) 7.0 Function Settings The Protean series offers the following function settings in the transmitter: Normal, ON-OFF, Toggle, and interlocked. By default they are set in an interlocked mode. Protean series radios can be custom programmed at the factory based on requirements and specific applications, please contact your distributor for more information. 701P PROTEAN RADIO CONTROLS MANUAL 15
16 8.0 Specifications 8.1 General 1. Enclosure: IP65 2. Structure: Glass Fiber/ABS 3. Operating Temperature: -45 ~ +80 o C -50 ~ +175 o F 4. Relay: 10A/250VAC (AC Power) 15A/12VDC (DC Power) 5. ID Code: 32bit (Greater than 4 Billion unique codes) 6. Hamming distance 7. Static > 15KV 8. Remote ID code setting 9. Operating range: Up to 328 ft (100 meters) 8.2 Transmitter (4, 6 & 8 Button Model) 1. L x W x H: 4.72 x 2.17 x 1.00 in. (120 x 55 x 25 mm) 2. Weight: 5.47 oz. (155g) (with batteries) 3. Uses 2 AA alkaline batteries 4. Low power indicator (LED flash red) 5. Pushbutton jammed detector 6. Shock resistant 7. Output power 4 mw 8. Normal power consumption: 10 ma 9. Sleep mode consumption: 1uA 10. Modulation: FM 8.2 Transmitter for (4 Button HT & 6 Button L8B) 1. L x W x H: 6.42 x 1.93 x 1.77 in. (163 x 49 x 45 mm) 2. Weight: 8.82 oz. (250g) (with batteries) 3. Uses 2 AA alkaline batteries 4. Low power indicator (LED flash red) 5. Pushbutton jammed detector 6. Shock resistant 7. Output power < 4 mw 8. Normal power consumption: 10 ma 9. Sleep mode consumption: < 1uA 10. Modulation: FM 8.3 Receiver 1. L x W x H: 6.34 x 2.91 x 2.05 in. (161 x 74 x 52 mm) 2. Weight: 2.43 lbs. (1.1kg) (w/out cable) 3. AC type: 48/110, 110/220, 220/380VAC DC type: 12V - 24VDC 4. Sensitivity: approx dBm 5. Shock resistant design 6.1 (4) independent common lines (U/D, E/W, S/N, R/O) for 8 Button & L8B Models. 6.2 (3) Independent common lines (U/D, E/W, R/O) for 6 Button Model. 6.3 (2) independent common lines (U/D, R/O) for 4 Button Model. 6.4 (2) independent common lines (U/D, E/W) for HT Models. 16 PROTEAN RADIO CONTROLS MANUAL 701P
17 Notes 701P PROTEAN RADIO CONTROLS MANUAL 17
18 Notes 18 PROTEAN RADIO CONTROLS MANUAL 701P
19 Notes 701P PROTEAN RADIO CONTROLS MANUAL 19
20 Conductix-Wampfler 2012 Subject to Technical Modifications Without Prior Notice USA / LATIN AMERICA F Street Omaha, NE Customer Support Phone Fax Phone Fax [email protected] [email protected] CANADA J.A. Bombardier Mirabel, QC J7J 0H5 Customer Support Phone Fax Phone Fax [email protected] MÉXICO Calle Treviño 983-C Zona Centro Apodaca, NL México Customer Support Phone (+52 81) (+52 81) (+52 81) Fax (+52 81) [email protected] BRAZIL Rua Luiz Pionti, LT 05, QD. L - Vila Progresso Itu, São Paulo, Brasil CEP: Customer Support Phone (+55 11) Fax (+55 11) [email protected] Contact us for our Global Sales Offices 20 PROTEAN RADIO CONTROLS MANUAL 701P
Conductor Bar Manual 8-Bar
Conductor Bar Manual 8-Bar 963000.2.2 8-BAR MANUAL 1 Conductix Incorporated The technical data and images which appear in this manual are for informational purposes only. NO WARRANTIES, EXPRESS OR IMPLIED,
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC
Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC BAYweb Remote Model BW-BCU5 Owner's Manual Copyright 2009-2010 Bay Controls, LLC Part Number: BW-BCU5DOC Revision: 0.2 April 18, 2010 BAYweb is a
24.2L M.A.N. V12 Engine Module
24.2L M.A.N. V12 Engine Module MANV1224 INSTALLATION INSTRUCTIONS For 24.2L M.A.N. V12 Engines V12 M.A.N. Engine Instructions Module ECM s (male and female, connect to the same ECM) ECM s (male and female,
Installation, Operation & Service Manual
Installation, Operation & Service Manual 0RQLWRU Pulse Monitor Software Version 1 0 1 Pulse Monitor Card Software Revision 1 4 0 Pulse Monitor Card Product Revision 0 1 0 0 February, 2007 Copyright 2007,
Radio Remote Controls Protean TM L Series K Series
Radio Remote Controls Protean TM L Series K Series Contents Radio Remote Controls 3 Protean TM Series 4-9 Protean TM, Basic Receivers and Transmitter 4-7 HT Series Transmitter 8 L8 Series Transmitter 9
ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX
ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX INSTALLATION INSTRUCTIONS Step 1. Determine the position for the Hands-free phone in the elevator phone
AGS. Owner's Manual. Xantrex Automatic Generator Start Control System
AGS Owner's Manual Xantrex Automatic Generator Start Control System TABLE OF CONTENTS INTRODUCTION...3 Main Features...3 Safety Summary...3 THINGS YOU SHOULD KNOW...4 THEORY OF OPERATION...5 System...5
Owner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.
Owner s Manual 1 Dear Customer, Thank you for purchasing this product. For optimum performance and safety, please read these instructions carefully. User Memo: Date of purchase: Dealer name: Dealer address:
INSTRUCTION MANUAL MODEL PCD-88
INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website:
DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060
DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060 (FOR DUSTTRAK II AND DRX AEROSOL MONITOR MODELS 8540 AND 8543) OPERATION AND MAINTENANCE MANUAL P/N 6008416, REVISION A MAY 2015 Copyright TSI Incorporated
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
i410/i1010 AC/DC Current Clamp
/i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, UK. Tel: +44 (0)1527 406800 Fax:
GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)
FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control
InHome Water Leak Detection Package
InHome Water Leak Detection Package For Model Numbers ILD10A-L and ILD10A-B Installation Guide / Wiring Diagram For Creating Water Leak Detection-based Events with Line-Powered or Battery-Powered Sensors
900 MHz Lightweight Wireless Stereo Headphones
33-1165.fm Page 1 Tuesday, August 10, 1999 10:50 AM Cat. No. 33-1165 OWNER S MANUAL Please read before using this equipment. 900 MHz Lightweight Wireless Stereo Headphones 33-1165.fm Page 2 Tuesday, August
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
Powerware Relay-Serial Card User s Guide
Powerware Relay-Serial Card User s Guide Special Symbols The following are examples of symbols used on the UPS and accessories to alert you to important information: This symbol indicates that you should
User Guide. HDMI Active Cable Extender. DVI-7370c
User Guide HDMI Active Cable Extender DVI-7370c TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY...1 1.0 INTRODUCTION...2 2.0 SPECIFICATIONS...3 3.0 PACKAGE CONTENTS...4 4.0 CONNECTING
Remote Alarm Monitoring System
Remote Alarm Monitoring System Operation and Service Manual Model RA1 RA4 A A Version HELMER SCIENTIFIC 14400 Bergen Boulevard Noblesville, IN 46060 USA PH +1.317.773.9073 FAX +1.317.773.9082 USA and Canada
INSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE
Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty
Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty Page 1 Table of Contents Introduction Page 3 Overview Page 3 Setup and Operation Page 5 Remote Control Page 6 Power Management Page
Energy & Data Transmission Systems for Waste Water Treatment
Energy & Data Transmission Systems for Waste Water Treatment Conductix-Wampfler Solutions for Waste Water Treatment 2 Conductix-Wampfler We move your business! Solutions for Waste Water Treatment Reliable
Weather Radio Alarm Clock
1200093 User s Guide Weather Radio Alarm Clock Thank you for purchasing your Weather Radio Alarm Clock from RadioShack. Please read this user s guide before installing, setting up, and using your new weather
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1
ITC-BTTN Cellular Bluetooth Gateway Owner s Manual 1 2 Table of Contents Introduction...3 Package Contents...3 XLink Connections Diagram...4 Setup...5 Pairing your Bluetooth Cell Phone to the XLink...6
Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.
Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver. OWNER'S MANUAL VR36A XC18A XM13A MODEL VK69A (INCLUDES XC18A CAMERA, XM13A
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger
Digital echo-charge Owner s Manual Xantrex Digital echo-charge Battery Charger Thank you for purchasing a Xantrex Digital echo-charge. Xantrex Technology Inc. takes pride in manufacturing quality products
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
HDMI Fiber Optic Cable. DVI-D Fiber Optic Cable. User Guide
HDMI Fiber Optic Cable DVI-D Fiber Optic Cable User Guide 1. Product Description Thank you for purchasing this HDMI Fiber Optic Cable. This cable is capable of transmitting digital HDMI (or DVI) signals
Model SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
INSTRUCTIONS FOR MAGNUM DS TRIP UNIT TESTING USING TEST KIT SYLES 140D481G02R, 140D481G02RR, 140D481G03 AND 140D481G04
I.L. 32-693 A INSTRUCTIONS FOR MAGNUM DS TRIP UNIT TESTING USING TEST KIT SYLES 140D481G02R, 140D481G02RR, 140D481G03 AND 140D481G04 DANGER DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTE- NANCE ON EQUIPMENT
7 High-Resolution Digital Photo Frame
TM 16-1003 User s Guide 7 High-Resolution Digital Photo Frame One demo photo included, as illustrated Please read this user s guide before using your new photo frame. Package contents Photo Frame AC Adapter
Ceiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
Mini Power Bank and Charger
Mini Power Bank and Charger Owner s Manual Please read before using this equipment. Your charger is ETL listed to UL standards and meets all applicable FCC standards. WARNING: To reduce the risk of fire
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity
About this Manual. Support for Your Product
About this Manual We ve added this manual to the Agilent website in an effort to help you support your product. This manual is the best copy we could find; it may be incomplete or contain dated information.
User s Manual. Bluetooth Calculator Keypad. Page
User s Manual Bluetooth Calculator Keypad Page Regulatory Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
Alarm Clock USER GUIDE
Alarm Clock USER GUIDE Jazwares, Inc. 2012 CONTENTS Please read the instructions along with the Alarm Clock carefully before you use it, so that you can operate it conveniently. WELCOME & Warnings Page
Leak Detection System
Instructions - Parts List Leak Detection System 311200A For detecting leaks in your diaphragm pump system. Not for use in explosive atmospheres. Part No. 234576 120 psi (0.8 MPa, 8 bar) Maximum Air Input
CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM
INTRODUCTION CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM Thank you for purchasing the CMD-8000 Commander from Dakota Digital. This, along with many other products that Dakota Digital has
WIRELESS STATUS MONITOR
INSTALLATION INSTRUCTIONS WIRELESS STATUS MONITOR (WSM or AUWSM) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-032-D Schlage 245 W. Roosevelt Road,
Dynatel 2273 Advanced Cable and Fault Locator
Dynatel 2273 Advanced Cable and Fault Locator Operators Manual September 1999 78-8097-6517-1-B TABLE OF CONTENTS Introduction... 2 Installing or Replacing the Batteries... 2 Initial Receiver Configuration...
User Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
TTL to RS232 Adapter User Guide
TTL to RS232 Adapter User Guide Revision D March 28, 2011 Document Part Number GC-800-313d Copyright and Trademark Copyright 2006-2011, Grid Connect, Inc. All rights reserved. No part of this manual may
Usage, Installation, Warranty and Service Information
T13C Table Updater for Seating Management U S E R M A N UA L Usage, Installation, Warranty and Service Information Long Range Systems, LLC 4550 Excel Parkway, Suite 200 Addison, TX 75001 800.437.4996 www.lrsus.com
User and Installation Guide
Connect the AC adapter with the amplifier BEFORE plugging the AC adapter into an outlet to avoid spark generation! User and Installation Guide BlueFIDELITYTM Bluetooth Audio Amplifier Model 300 Contents
Model 3000-51 20 SPDT Relays 90401460
Model 3000-51 20 SPDT Relays 90401460 Page 1 All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part of Giga-tronics,
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
HM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
GSM Gate Opener GSM Remote Switch RTU5015 User Manual
GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener
WD-AMX Water Detection Controllers
Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation
Zetron Desktop Microphone Manual 025-9589F
Zetron Desktop Microphone Manual 025-9589F Software License The Zetron software described in this manual is subject to the terms and conditions of Zetron's Software License Agreement, a copy of which is
±15 V Current-Limited Power Supply
USER S GUIDE ±15 V Current-Limited Power Supply Model 0901 Newport Corporation 3635 Peterson Way Santa Clara, CA 95054 www.newport.com/newfocus Warranty Newport Corporation guarantees its products to be
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
Instructions for Connecting PETROSMART EZ Control Systems To Wayne Electronic Dispensers With/Without CAT CREDIT CARD MODULES
Installation Instructions Instructions for Connecting PETROSMART EZ Control Systems To Wayne Electronic Dispensers With/Without CAT CREDIT CARD MODULES Read This Book This book has important information
e-ask electronic Access Security Keyless-entry
e-ask electronic Access Security Keyless-entry e-fob Keyless-entry entry System Full-Function Function Installation Manual FCC ID: TV2EFOB1 (UM20 ~ 22793-02) Table of Contents Introduction... 1 e-fob Operation
VARIO PROX CARD READER INSTALLATION MANUAL
VARIO PROX CARD READER INSTALLATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION...2 1.1 Legend...3 1.2 Terminology...4 2.0 MOUNTING...5 3.0 WIEGAND CONNECTION...6 4.0 AUX BUTTON INPUT...7 5.0 INSTALLER PROGRAMMING...8
Safety Manual BT50(T) Safety relay / Expansion relay
Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document
Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.
Warranty Terms QLogic Corporation ("QLogic") provides the following warranties to the original purchaser of QLogic products from QLogic or, in the case of resale, to the initial end user customer (the
UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS
UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS CONTENTS Parts List... 2 Parts Diagram... 2 Helpful Hints... 3 Installation... 4 Operation and Troubleshooting Guide... 6 Warranty Information... 8 Form #3132,
VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.
Pushbutton Switch (Cylindrical 10.5-dia.) CSM DS_E_4_4 Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment Momentary operation and lock. available in six colors.
Single Station Remote Alarm
ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free 1 866 295 6775. www.powerbright.com
WARNING: This Unit employs Components that tend to produce arcs or sparks To prevent fire or explosion, do not install in compartments containing batteries or flammable materials - SHOCK HAZARD. DO NOT
Unattended Answering Device Instruction Manual
Model 3137B Unattended Answering Device Instruction Manual Monroe Electronics 100 Housel Ave Lyndonville NY 14098 800-821-6001 585-765-2254 fax: 585-765-9330 monroe-electronics.com Printed in USA Copyright
Installation & Operation Manual
GET CONNECTED Installation & Operation Manual DEVICE INTEGRATION AND CHARGING KIT TranzIt USB IS32 Note to Readers, The information contained within the following documentation is subject to change without
ABR Brake Rectifier Instruction Manual
ABR Brake Rectifier Instruction Manual Part Number: 552074 Copyright 2012 Magnetek 1. Preface and Safety All rights reserved. This notice applies to all copyrighted materials included with this product,
Machine Safety Switch: SI-LM40 Series Limit Switch Style
Machine Switch: SI-LM40 Series Limit Switch Style SI-LM40 Series Limit Switch Style with Flexible In-Line Actuator Positive-opening safety contacts (IEC 60947-5-1) (not dependent upon springs) Standard
WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL
WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL CAUTION: This system is not for use with antenna in raised position while
Installation and Operation Guide PD4600 Series Converter Replacement
Installation and Operation Guide PD4600 Series Converter Replacement Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as your
Universal Wireless Effects Controller USER S GUIDE SA115
Universal Wireless Effects Controller USER S GUIDE SA115 Welcome Thank you for purchasing this Hot Hand 3 Universal Wireless Effects Controller. We hope that the new functionality of the Hot Hand 3 unit
3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
u-traq autopro GPS Vehicle Tracking System Product # 1020-PRO User s Guide Installation and Operating Instructions
u-traq autopro GPS Vehicle Tracking System Product # 1020-PRO User s Guide Installation and Operating Instructions Before Installing Table of Contents Before Installing 2 GPS Fundamentals 3 Checking the
Targus Wireless RF Mouse USER S GUIDE. Making Your Mobile Life Easier.
Targus Wireless RF Mouse Visit our Web site at: www.targus.com Features and specifications are subject to change without notice. 2004 Targus Group International and Targus, Inc.. 400-0111-001B USER S GUIDE
POWER GEAR SLIDE OUT MANUAL
POWER GEAR SLIDE OUT MANUAL Operation Guide FLUSH FLOOR SLIDE OUT SYSTEM FOR AMERICAN COACH PRODUCTS 82 S0220 01 Rev. 1 AMERICAN COACH SLIDE OUT MANUAL FLUSH FLOOR SYSTEM TABLE OF CONTENTS SECTION PAGE
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
READ FIRST! Universal Car/Air Adapter User Manual
AutoAir Manual 1/9/03 2:03 PM Page 1 READ FIRST! Universal Car/Air Adapter User Manual Congratulations! Your new Kensington Universal Car/Air Adapter is a highly efficient Universal Car/Air Adapter for
NOTICE D UTILISATION USER MANUAL. Spy RF Alarm 06255C. JRI Maxant 1
NOTICE D UTILISATION USER MANUAL Spy RF Alarm 06255C JRI Maxant 1 TABLE OF CONTENTS I. INTRODUCTION... 10 a) Equipment... 10 b) Symbols... 10 II. INSTALLATION RECOMMENDATIONS... 10 a) Perturbation sources...
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
Load Cell Amplifier Module. Instruction Manual LCA210-000
Load Cell Amplifier Module Instruction Manual LCA210-000 Table of Contents 1. General Description...3 2. Specifications...3 2.1 Electrical...3 2.2 Physical...4 3. Installation...4 3.1 Wiring Guidelines...4
F2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS
Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.
BC-5000 BATTERY CAPACITY TESTER OPERATIONS MANUAL COFKO LLC. COPYRIGHT 2010 1 UNPACKING As you unpack your new BC-5000 battery capacity tester, inspect the tester for signs of shipping damage. If shipping
u-traq autopro GPS Vehicle Tracking System Product # 1020-PRO User s Guide Installation and Operating Instructions
u-traq autopro GPS Vehicle Tracking System Product # 1020-PRO User s Guide Installation and Operating Instructions Table of Contents Before Installing 2 GPS Fundamentals 3 Checking the Contents of the
PagePac PAGEPAL V-5335700
PagePac Issue 3 by PAGEPAL V-5335700 INTRODUCTION The PagePal unit interfaces most telephone systems (PBX, KTS, Centrex) to virtually any public address audio system. In addition, PagePal furnishes inputs
PixController, Inc. Wireless Digital PIR Sensor
PixController, Inc. Wireless Digital PIR Sensor Model: SEN-400 User s Manual Version 1.00 WARRANTY REGISTRATION PixController, Inc. warrants products sold by it and guarantees to correct, by repair or
Triple Expansion Chassis
Triple Expansion Chassis AP9604 Installation Manual Contents Introduction............................. 1 Installation.............................. 2 Power Considerations...................... 5 Operations..............................
REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion
REDI-LINE ELECTRIC GENERATORS USER'S GUIDE Rugged, Reliable, DC to AC Power Conversion REDI-LINE ELECTRIC GENERATOR MODEL INPUT ACTUAL OUTPUT ACTUAL OUTPUT WATTS SERIAL NO. PACIFIC SCIENTIFIC MOTOR PRODUCTS
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
