MTCS Modular Train Control System

Size: px
Start display at page:

Download "MTCS Modular Train Control System"

Transcription

1 MTCS Modular Train Control System SIL 4 Railway Computer for Rolling Stock and Wayside Applications In Accordance with: EN EN EN EN EN 50128

2 The MTCS Approach... 4» MTCS Modular Train Control System» Safety Compliance with EN 5012x» Environmental Compliance with EN 50155» Long-Term Availability MTCS Architecture...8» Safe MTCS Controller» Safe MTCS Remote I/O Box» Safe MTCS CPU Component» Safe MTCS I/O Components» MTCS Configuration Examples» Safe MTCS Real-Time Ethernet Topology» MTCS Software Architecture» MTCS Safety Guaranteed by TÜV Certificate MTCS Application Areas... 18» Rolling Stock» Wayside MTCS Benefits Summary The governments of many countries have increased their safety standards in mass transit and freight transport and / or work on nationwide traffic regulation programs, e.g.:» SIRF stage 2 (Germany)» PTC Positive Train Control (USA)» ETCS European Train Control System» CTCS Chinese Train Control System» KLUB-U Russian Train Control System

3 The MTCS Approach MTCS is an open and modular railway computer platform based exclusively on standard hardware and software. It is certifiable up to SIL 4 in all its single parts and complies completely with the EN and EN railway standards. MTCS is designed to operate in rolling-stock applications such as Automatic Train Control (ATO) and Automatic Train Protection (ATP) as well as in wayside applications like interlocking systems. MTCS consists of the safe controller, the safe I/O functions and the communication interfaces to the outside world. The final safety level of MTCS is scalable and as such solely determined by the application requirements resulting in an optimum price / performance. MTCS Modular Train Control System MTCS is the first computer system ever in the history of the railway industry that separates the control electronics the computer hardware from the real control function the application software. Unlike existing solutions that are proprietary and show a fixed hardware/software configuration which is closed to the access of the end user, MTCS opens up the essential interfaces between the control electronics and the application. MTCS is therefore the first and only railway computer that is based on defined open standards for hardware, software and communication. Its modularity makes it configurable for every control function inside and outside the train and scalable to any required SIL level. MTCS comes with certification packages from TÜV Süd, drastically reducing the time of the certification process. The SIL 4 certifiable and real-time capable kernel supports the partitioning of the application dependent on the required safety level, thus reducing the software development effort. The non-safe and Linux based part for communication and service is completely separated. It guarantees that the system is open towards the external world. The data transfer of the inputs and outputs is realized via a safe real-time Ethernet. Based again on an industry standard, also the safety of the I/O communication is proven by TÜV Süd. Being a totally open platform concerning software and hardware, MTCS is the first and only railway computer that offers a separation of the rail service from the electronic control system behind. This unique feature allows railway system suppliers to concentrate on their core business. It also facilitates the market entry for small and medium-size companies. And it enables rail operators to become their own general contractor, keeping full transparency of their project at any time. 4 5

4 Safety Compliance with EN 5012x MTCS complies with the requirements of the EN 5012x family of railway standards developed by CENELEC, based on IEC (Functional Safety of Electrical / Electronic / Programmable Electronic Safety-related Systems):» EN 50126: Railway Applications The Specification and Demonstration of Reliability, Availability, Maintainability and Safety (RAMS)» EN 50128: Railway Applications Communications, signaling and processing systems» EN 50129: Railway Applications Communications, signaling and processing systems Safety related electronic systems for signaling MTCS components come with SIL 4 certification packages for the hardware, with complete support for the safe operating system QNX (PikeOS on request), including safe protocols, CST layer, I/O transfer layer etc. Long-Term Availability MEN guarantees long-term availability of all parts of the MTCS for a minimum period of 10 years. After this period it might happen that single chips or electronic components can be made obsolete by one of our suppliers. In the worst case, this might result in the exchange of one or the other board in the MTCS system. As all these boards are standards-based, the application itself will remain untouched to a great extent. If it becomes necessary to exchange such a standard board, MEN delivers a change effect analysis together with the redesign. This ensures that the effort for re-porting of the application as well as for a potential re-certification will be reduced to a minimum. Using an open system like MTCS means that product obsolescence management can be limited to single standardized parts of a train control system or interlocking system. It will never again affect and endanger the complete train or wayside function. Environmental Compliance with EN MTCS also complies with the EMC regulations of EN : Railway Applications Electromagnetic compatibility. (Emission and immunity of the signaling and telecommunications apparatus). 6 Linux E SCAD ANSY S PLC General Purpose User Software Sof t» Operating temperature class Tx: 40 to +70 C (10 minutes up to +85 C) with qualified components» Shock: 50 m/s², 30 ms (EN ( ) / EN 61373)» Vibration (function): 1 m/s², 5 Hz 150 Hz (EN ( ) / EN 61373)» Vibration (lifetime): 7.9 m/s², 5 Hz 150 Hz (EN ( ) / EN 61373)» Humidity, dust: conformal coating» PSU class 2 hold-up times with just one wide range PSU 14.4 to 154 V» 14.4 to 154 V also supported by I/O components» EMC regulations:» EN (tables 5 and 6) / EN (radio disturbance)» EN (table 9) / IEC (ESD)» EN (table 9) / IEC (electromagnetic field immunity)» EN (table 8) / IEC (burst)» EN (table 8) / IEC (conducted disturbances) Sa Appl fe User i ca t io n C MTCS complies with all environmental requirements of EN (Railway Applications Electronic equipment used on rolling stock) for in-vehicle operation: QNX MTCS Hardware 7

5 MTCS Architecture The heart of the MEN Train Control System is the MTCS controller which delivers state-of-the art computing performance based on x86 PC technology. The MTCS controller consists of a safe part and what is called an unsafe (general purpose) part. The MTCS controller can be used as a standalone device and in combination with up to 63 remote I/O boxes. Safe MTCS Controller The communication inside the MTCS system between the safe MTCS controller, safe I/O boards and safe remote I/O boxes is based exclusively on a safe standard real-time Ethernet. Its modular configuration enables the MTCS system to communicate with other train systems like service or diagnosis units via any type of wired or wireless interface. Additionally, fieldbus interfaces can be implemented to connect into other networks like MVB, CAN, Profinet etc. This makes it easy to integrate into a TCN network as well as into regionally different Train Control Systems like PTC, ETCS, CTCS, ATCS or Klub-U. MTCS is an application-ready platform, allowing the immediate start of the application development and giving the user complete control over the functionality of the whole system. While the unsafe part of the application runs under a Linux operating system, the safe part of the application runs in a safe kernel of the real-time operating system QNX. The safe application can either be directly programmed with the Posix standard C language or optionally Flexisafe safe PLC. MTCS is SIL 4 certifiable and comes with pre-certified hardware in combination with pre-certified software and corresponding certificates from TÜV Süd.» The high level of modularity of the hardware and the software of the MTCS system allows to use MTCS as the sole platform for a multitude of varying rail applications.» As the whole MTCS system is based on standards, also the life-cycle cost of each rail project can be drastically reduced.» The pre-certification of the MTCS hardware and software results in significant cost and time savings during computerization of the train, whether a vehicle is new or is being refurbished. The MH50C MTCS controller supports a modular built-to-order configuration and consists of:» Certifiable safe CPU board with local redundancy» Up to 6 I/O boards:» Either certifiable safe I/O boards» Or interface boards to Ethernet, WiFi, GPS, COMs, CAN, MVB etc.» Or a combination of both» 14.4 to 154 V DC wide-range voltage supply» QNX safe real-time operating system» Linux unsafe operating system» SIL 4 certification packages by TÜV Süd To raise availability of the safe MTCS system, the functionality of two MTCS controllers can be clustered in one enclosure. MH50C comes in a compact half 19" housing based on the established CompactPCI standard. The CPU board and I/O boards comply with the robust 3U Eurocard format. The system can be wall or rackmounted and supports forced air cooling. 8 9

6 Safe MTCS Remote I/O Box Safe MTCS CPU Component The central element of MTCS is the safe CPU board F75P, a standard CompactPCI board that is designed to execute safety-critical applications as well as unsafe applications and comes with a dedicated certification package: An extension of the MTCS system by remote I/O boxes (KT4, KT6, KT8) becomes necessary if:» The I/O functions required exceed the capabilities of the MTCS controller» The actors and sensors are located far away from the MTCS controller Each MTCS remote I/O box consists of:» Up to 4, 6, or 8 certifiable safe I/O boards» Real-time Ethernet interface with chassis configuration switch» 14.4 to 154 V DC wide-range PSU» Certification packages by TÜV Süd for the safe I/O The remote I/O boxes are based on 19" technology, with a reduced depth of less than 160 mm to provide a compact space-saving packaging. They can be either wall mounted or installed on DIN rail mechanics.» 2 redundant Intel processors to execute safety logic» 3rd Intel CPU as general purpose and I/O communication processor» Independent supervisors for each block» Fail-safe and fail-silent board architecture» Hot or cold stand-by» Clustering of two F75P to raise availability» Event logging with intelligent board management controller In the MTCS standard configuration and as such included in the certification packages available, the two independent control processors run the safe deterministic real-time operating system QNX Neutrino, while the unsafe general purpose processor operates under Linux. Other MTCS configurations can also work with safe real-time operating systems such as PikeOS, Integrity or VxWorks even in a combination of different safe operating systems to support optional diversity in software on both kernels

7 Safe MTCS I/O Components MTCS Configuration Examples MTCS System Controller: MH50C Configuration Example 1 Option slots populated with safe I/O» 8 digital outputs, SIL 4 (each using 2 pins)» 16 digital inputs, SIL 4 (each using 2 pins)» 8 frequency input channels, SIL 4 The SIL 4 certified safe I/O boards comprise the typical functions required for railway applications and come with dedicated certification packages:» K1 8 binary outputs» K2 16 binary inputs» K3 safety relay outputs in preparation» K4 4 frequency inputs, used to measure the speed of the train via wheel sensors» K5 analog outputs in preparation» K6 analog inputs in preparation All I/O components connect via spring cage terminal blocks for fast installation thanks to reduced wiring. They are fully isolated and support the full voltage range from 14.4 to 154 V DC. Generally a single K board can be used to reach SIL 2. Two combined boards are required to reach SIL 3 and SIL 4. This scalable approach reduces cost in case a lower SIL level is sufficient. The safe MTCS I/O cards are designed to be used inside the MH50C MTCS controller as well as to configure the MTCS remote I/O boxes:» MH50C accommodates up to 6 safe I/O cards» KT8 accommodates up to 8 safe I/O cards» Further remote I/O boxes will be able to accommodate smaller numbers of safe I/O cards for installation areas with very limited space. MH50C Configuration Example 2 Option slots populated with safe I/O» 8 digital outputs, SIL2» 16 digital inputs, SIL 2» 4 frequency input channels, SIL 2» MVB master» 2 slots reserved for future use This configuration targets SIL 2 safe I/O applications: each safe I/O card is only assembled once. Both configuration examples are based on the barebone configuration, which includes the safe F75P CPU board, real-time Ethernet card connecting distributed safe I/O, a wide-range PSU and system supervision

8 Safe MTCS Real-Time Ethernet Topology MTCS Remote I/O Boxes: Configuration of a KT8 providing» 8 SIL 4 outputs (each using 2 pins) + 8 SIL 2 outputs» 16 SIL 4 inputs (each using 2 pins) + 16 SIL 2 inputs» 4 SIL 4 frequency input channels (using 2 separate frequency counters) MTCS Controller Real-Time Ethernet Master BC Configuration of a KT4 providing MTCS Controller MTCS I/O MTCS I/O BC BC I/O Boards I/O Boards Real-Time Ethernet Master BC» 8 SIL4 outputs (each using 2 pins)» 16 SIL2 inputs» 4 SIL2 frequency input channels I/O Boards MTCS System Controller in Combination with Remote I/O Boxes: MTCS Controller I/O Boards The complete MTCS I/O no matter whether it is part of the MH50C controller or located in the remote I/O boxes is connected via real-time Ethernet. Thus, the application can treat all I/O functions in the same way. All remote I/O boxes are connected to the controller in a ring topology, which tolerates single failures. For example, in case of a broken cable, the system is still fully operational, as all I/O boxes can still be reached from the other end of the ring. MTCS Remote I/O 14 MTCS Remote I/O MTCS Remote I/O 15

9 MTCS Software Architecture MTCS Safety Guaranteed by TÜV Certificate Safe Domain (CPU Board) User Safety Application User Safety Application Safety Communication Layer Compare Safety Communication Layer Compare Safe QNX/Safe BSP Safe QNX/Safe BSP TÜV Certificate TÜV Assessment Report Safety Case Safety User Guide Communication (Shared RAM, Virtual Ethernet) I/O Domain (CPU Board) Black Channel F75P QNX BSP None-Safe Application Communication Diagnosis, Services Driver Libraries Linux (Soft Real-Time) QNX Drivers External Interfaces Safe Domain (I/O Board) Safety Communication Layer The MTCS software distinguishes between the safe and the unsafe domain in order to save cost and time for application development and certification. This separation allows to develop unsafe ty relevant applications separately from safe applications. Unsafe applications cannot influence safe applications because they are executed on a separate processor running a standard Linux operating system. In order to guarantee appropriate communication between the safe controller and the safe I/O functions via real-time Ethernet, the so called black channel approach is applied. The method to transport safe data over untrusted communication is defined by EN The complete MTCS solution may contain safe and unsafe parts. For the safe parts of the system two certification packages are provided:» For the F75P CPU board of the MH50C system controller including QNX Board Support Package» For the I/O cards including QNX drivers Each SIL 4 railway certification package according to EN 5012x includes a number of documents:» Safety User Guide including the safety-relevant application requirements, a detailed description of the hardware and instructions for appropriate operation» Safety Case describing the concepts for reaching functional safety as well as all safety and quality-relevant processes and measures to meet the SIL 4 requirements» Assessment report and SIL 4 certificate from TÜV SÜD (German Technical Inspection Agency) 17

10 MTCS Application Areas Wayside Rolling Stock Gear Control Fuel Control Wheelslip Control Driver Display Driver Cab Controls/Indicators MTCS Controller MTCS Remote I/O Valves, Relays, Sensors MTCS is both well suited for use in new interlocking systems and for a soft modernization and automation of older relay interlockings. Existing outside facilities can be preserved and adapted. The extremely compact inside facility of an interlocking system is clearly separated and forms the safe platform (SIL) for the control and automation layer. MTCS is compact, safe and robust in accordance with EN and EN (EMC). MTCS enables: Brakes Ethernet Train Bus (MVB, CAN) I/O Bus (CAN, Profibus) MTCS is well suited for use in new train models as well as for refurbished trains. Thanks to its modularity, it is easy to install and retrofit safety and automation functions with MTCS in any type of older rail vehicle as well.» Introduction of ETCS (European Train Control System) L2/L3 for optimization of safety and track load» Halving of the resulting opportunity cost for relay interlocking systems» Reduction of dependence from single suppliers, resulting in a growing service offer» Increase of the performance of the interlocking systems» Decrease of life cycle cost» Avoidance of the costly total replacement by electronic interlocking systems (incl. outside facilities)» Installation of simpler, smaller and standardized inside facilities» Longer operating life of the outside facilities» Lower cost for the increase of total capacities» Low cabling cost thanks to standardized Ethernet technology MTCS is:» Compact, safe and robust in accordance with EN 50155» A versatile, consistent, open and safe platform for all functions like ATO, ATP, PTC, ETCS» Safe control system plus communication system all in one, but strictly partitioned» Fully compatible with EN50155 (incl. all temperature and voltage ranges)» Safe remote I/O, connected via redundant, real-time Ethernet» The interface to all existing train communication such as MVB, WTB, CAN» The wireless communication interface to the outside world through GSM-R, GPS, WLAN 18 19

11 MTCS Benefits Summary Safety Open Hardware Standard Safety levels SIL 4, SIL 3, SIL 2, SIL 1, SIL 0 Redundancy Fail-silent Fail-safe Fail-operational Flexible configuration of safety levels results in optimum price/performance Provides safety by means of 2 control processors on a single CPU board The system provides the correct service or remains silent. The system will not endanger lives or property when it fails. Clustering of hardware components if the system must stay operational Standard PC hardware architecture Main controller with Intel CPU board architecture CompactPCI State-of-the-art X86 host controller» Safety execution with 2 redundant processors» 1 general purpose processor» Independent supervisors for each block Robust industry-proven backplane and computer board standard 19" systems Well-known enclosure standard 3U Eurocard format Robust board standard Open Safe Platform I/O connectivity Spring-cage terminal blocks make connection easy and reduce cabling Safe API (Application Interface) QNX Real-time Operating System» POSIX compliant» C programming language Partitioning of the application for different safety levels 14.4 to 154 V DC wide-range PSU International railway compliance with just one system Open Communication Extensions Open General Purpose Platform Railway fieldbusses Connection to existing TCN network via MVB & WTB interface boards Linux Operating System Development of unsafe part of the application in familiar standard software environment Other fieldbusses Connection to existing train devices via CAN, ProfiNet etc. interface boards Ethernet Connection to standard switches and routers Open I/O Ethernet communication Real-time Ethernet communication Functional safety over Ethernet» Makes use of standard cabling, line interfaces» Connects main control system and remote I/O boxes Guarantees deterministic behavior on standard communication protocol Black channel for safe TÜV certified I/O communication WIFI, radio, GPS, RS485 Functionality Open API for C or safe PLC Connection to all popular in-vehicle and external communication interfaces Freely programmable or Flexisafe PLC software environment Safe modular railway I/O up to SIL 4» Digital inputs/outputs (wide range EN compliant)» Analog inputs/outputs (wide range EN compliant)» Frequency inputs (detection of hold, frequency, period, pulse width, direction distance, encoder supply)» Relay outputs (wide range EN compliant) Safe programming Physical software separation between safe and unsafe domain» In C language» Or based on Soft SPS» Or ANSYS SCADE model-based Saves time and cost for application development and certification LInux For general purpose and open communication 20 21

12 Standards Compliance EN50155 & EN Fully proven for rolling stock and wayside railway environments EN 50126/128/129 (based on IEC 61508) Developed for functional safety from SIL 0 to SIL 4 SIL 4 certification packages with TÜV Süd certificate Modular hardware/software packages make certification of the final application easy and fast Customer Support Long-term availability Life-cycle management 10 years guaranteed to save time and cost investment of the project Secures overall operability of the application when single components need to be substituted Development services Environmental test services Worldwide sales support Consultancy Experienced supplier of reliable embedded computer solutions Defining the appropriate solution together with the customer IRIS certified partner of the railway industry for many years February 2015 Copyright MEN Micro Inc. / MEN Mikro Elektronik GmbH / MEN Mikro Elektronik SAS All rights reserved. 22

13

Foxboro Evo Process Automation System

Foxboro Evo Process Automation System Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module

More information

FAdC i FRAUSCHER Advanced Counter i

FAdC i FRAUSCHER Advanced Counter i FAdC i FRAUSCHER Advanced Counter i EN FAdC i FRAUSCHER Advanced Counter i Track vacancy detection for special requirements The FAdCi is a particularly cost-effective version of the latest generation of

More information

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Available with a safe bus system or/and two counter inputs

More information

NCC Blade Network Communication Controller

NCC Blade Network Communication Controller In order to suit the permanent need of POS networking around the world, Ingenico has designed the (NCC). NCC can be used as LAN Controller Transaction router Dial-up POS concentrator NCC modular design

More information

Safety PLC for rolling stock Safety Controller Pluto Harsh Environment

Safety PLC for rolling stock Safety Controller Pluto Harsh Environment Safety PLC for rolling stock Safety Controller Pluto Harsh Environment Safety PLC for rolling stock More reliability and safety The requirements for rail vehicles of today and tomorrow grow constantly.

More information

imc BUSDAQ autonomous intelligent synchronized Field bus data acquisition - from stationary to mobile imc productive testing

imc BUSDAQ autonomous intelligent synchronized Field bus data acquisition - from stationary to mobile imc productive testing imc BUSDAQ autonomous intelligent synchronized Field bus data acquisition - from stationary to mobile imc productive testing www.imc-berlin.com/busdaq imc BUSDAQ/BUSLOG at a glance Processes multiple networks

More information

applicomio Profibus-DP

applicomio Profibus-DP BradCommunications Profibus-DP network interface cards allow deterministic I/O data acquisition for PC-based control applications. Features New! Support of Windows 32-bit and 64-bit (WoW64) Support of

More information

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053. PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection

More information

Modular I/O system Rugged Modular I/O System Solutions EN-50155 certified for railway applications

Modular I/O system Rugged Modular I/O System Solutions EN-50155 certified for railway applications The systems and devices of the MODULAR I/O family are the Tecnint HTE solutions for industrial and technological application of automation, acquisition and management that require particularly robustness

More information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

EtherCAT Cutting Costs with High-speed Ethernet

EtherCAT Cutting Costs with High-speed Ethernet EtherCAT Cutting Costs with High-speed Ethernet The real-time Ethernet fieldbus for automati 2 Real-time Ethernet down to the I/O level Low system costs Flexible topology Maximum performance Easy configuration

More information

ISpac isolators. the perfect system

ISpac isolators. the perfect system ISpac isolators the perfect system 2 safe isolation Handling flammable and potentially explosive substances is part and parcel of everyday operations in many branches of industry. However, it is not possible

More information

Remote Monitoring and REC 501 Control Unit Product Guide

Remote Monitoring and REC 501 Control Unit Product Guide Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the

More information

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8 CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection

More information

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4 Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BL ident extension cables Mixed operation of HF and UHF read/ write heads Connectors /S2500 Type code Ident

More information

Designing Industrial Network - An Approach

Designing Industrial Network - An Approach Designing Industrial Network - An Approach Happiest People Happiest Customers Contents Abstract...3 Introduction...3 What is Industrial networking?...4 Industrial Network Design consideration....4 Industrial

More information

Connectivity solutions for transport automation

Connectivity solutions for transport automation Connectivity solutions for transport automation The Belden product portfolio puts you on the fast track to highly available data communications in the transport automation industry. Uncompromising traffic

More information

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,

More information

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Expandable with a safe bus system

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Expandable with a safe bus system E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Expandable with a safe bus system Reduction of expenditures

More information

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s TECHNICAL SPECIFICATIONS zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s 2015 LitePoint, A Teradyne Company. All rights reserved. The LitePoint zseries 18-slot chassis is an

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Straton and Zenon for Advantech ADAM-5550. Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

Straton and Zenon for Advantech ADAM-5550. Copalp integrates the straton runtime into the ADAM-5550 device from Advantech Straton and Zenon for Advantech ADAM-5550 Copalp integrates the straton runtime into the ADAM-5550 device from Advantech Project Introduction: Programmable Application Controllers (PAC) are powerful and

More information

Provides one channel for Ethernet over existing

Provides one channel for Ethernet over existing LB304A LBPS301A LBPS304A Hardened Ethernet Extender Quick Start Guide Provides one channel for Ethernet over existing voice-grade copper twisted-pair wire. copper BLACK wire. BOX Customer Support Information

More information

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server Blade Made Easy Fujitsu PRIMERGY BX Blade Servers provide a faster, simpler and lower-cost way to build and run an IT infrastructure in your midsize organization,

More information

MiTraC Train ConTrol and ManaGeMenT system. Propulsion & Controls. This is a running title

MiTraC Train ConTrol and ManaGeMenT system. Propulsion & Controls. This is a running title MiTraC Train ConTrol and ManaGeMenT system 1 Propulsion & Controls The Brain of the Train A train speeding across the landscape at over 350 km/h is an impressive sight. So impressive it is, easy to forget

More information

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Using installed Fieldbus Wiring to carry Ethernet Communications

Using installed Fieldbus Wiring to carry Ethernet Communications Using installed Fieldbus Wiring to carry Ethernet Communications Modbus Plus, Data Highway, GE Genius, Profibus, ControlNet, DeviceNet, InterbusS and many other RS232 or RS4422 cables Key Issues when upgrading

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION MACHINEMATE CNC SYSTEM Hardware SPECIFICATION Feb 2005 CONTENTS 1 Introduction / General... 3 1.1 Superior Capability in Technology and Productivity... 3 1.2 General hardware components... 4 1.3 Static

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

MITRAC 500. Driven by Reliability. Propulsion & Controls

MITRAC 500. Driven by Reliability. Propulsion & Controls MITRAC 500 Driven by Reliability Propulsion & Controls MITRAC Low Power exceeding your expectations The BOMBARDIER* MITRAC* 500 product portfolio is a family of propulsion systems for light rail vehicles

More information

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev: 5-16-14 1

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev: 5-16-14 1 SuperIOr Controller The SuperIOr Controller is a game changer in the world of high speed embedded control. The system combines incredible speed of both control and communication with revolutionary configurable

More information

How To Use The Vacon 0 Machinery

How To Use The Vacon 0 Machinery vacon 0 machinery how would you like your ac drive today? easy adaptation for customer requirements The Vacon 0 Machinery is an extremely compact AC drive for machine builders in the power range from 0.25

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd Overview and Applications of PROFINET Andy Verwer Verwer Training & Consultancy Ltd What exactly is PROFINET? PROFINET is an open Industrial Ethernet standard developed by the PROFIBUS Organisation. PROFINET

More information

Process Alarm Solutions

Process Alarm Solutions Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical

More information

ABB North America. Substation Automation Systems Innovative solutions for reliable and optimized power delivery

ABB North America. Substation Automation Systems Innovative solutions for reliable and optimized power delivery ABB North America Substation Automation Systems Innovative solutions for reliable and optimized power delivery Substation Automation Systems Advanced substation automation, protection and control solutions

More information

Bar code scanners CLV45x / CLV450 / Standard Density

Bar code scanners CLV45x / CLV450 / Standard Density ONLINE DATA SHEET www.mysick.com Bar code scanners CLV45x / CLV450 / Standard Density CLV450-0010 Bar code scanners CLV45x / CLV450 / Standard Density Model Name > CLV450-0010 Part No. > 1018556 At a glance

More information

Company Profile. www.mioselettronica.com

Company Profile. www.mioselettronica.com Company Profile INDEX Who we are Mission How: Organization and R&D Railway Division Products References Oil & Gas Division Products References Contacts 2 WHO WE ARE MIOS Elettronica was built up in 2011

More information

Ponto Series. A new concept for automation

Ponto Series. A new concept for automation Ponto Series A new concept for automation Programmable Controller Remote I/O for Field Buses Special models of I/O modules Web connection Ponto Series Programmable Controller High connectivity CPUs Direct

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

ABB RTU560A Series CMU & Modules

ABB RTU560A Series CMU & Modules ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power

More information

THEME Competence Matrix - Electrical Engineering/Electronics with Partial competences/ Learning outcomes

THEME Competence Matrix - Electrical Engineering/Electronics with Partial competences/ Learning outcomes COMPETENCE AREAS STEPS OF COMPETENCE DEVELOPMENT 1. Preparing, planning, mounting and installing electrical for buildings and industrial applications He/She is able to prepare and carry out simple electrical

More information

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Vibration analysis and monitoring Compact. Powerful. Modern technology. Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device

More information

Syslogic Product Overview. Embedded Computer HMI Systems Single Board Computer Railway Computer

Syslogic Product Overview. Embedded Computer HMI Systems Single Board Computer Railway Computer Syslogic Product Overview Embedded Computer HMI Systems Single Board Computer Railway Computer Table of contents Syslogic product overview Is there anywhere you can still find true industrial-grade electronics?

More information

EP2002 Distributed Brake Control

EP2002 Distributed Brake Control EP2002 DISTRIBUTED BRAKE CONTROL RAIL VEHICLE SYSTEMS EP2002 Distributed Brake Control APPLICATIONS Light Rail Vehicles Metros Monorails Regional and Commuter Trains EP2002 DISTRIBUTED BRAKE CONTROL 2

More information

Motherboard- based Servers versus ATCA- based Servers

Motherboard- based Servers versus ATCA- based Servers Motherboard- based Servers versus ATCA- based Servers Summary: A comparison of costs, features and applicability for telecom application hosting After many years of struggling for market acceptance, it

More information

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management Energy Depot GmbH Delivering Solutions for Energy Management PRODUCT AND APPLICATION GUIDE Total Monitoring Solution for PV SOLAR LOGGER & ANALYSIS DC STRING MONITORING Residential Comprehensive Solar

More information

evm Virtualization Platform for Windows

evm Virtualization Platform for Windows B A C K G R O U N D E R evm Virtualization Platform for Windows Host your Embedded OS and Windows on a Single Hardware Platform using Intel Virtualization Technology April, 2008 TenAsys Corporation 1400

More information

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2 PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2 PEPPERL+FUCHS IN PROCESS AUTOMATION PEPPERL+FUCHS COMPANY OVERVIEW BUSINESS OVERVIEW Pepperl+Fuchs offers

More information

Scout 1U Rackmount Computer

Scout 1U Rackmount Computer Model Numbers ACC-CPU-RM- WIN7x64 ACC-CPU-RM-2008 Revision 5 Scout 1U Rackmount Computer Introduction The Scout 1U Rackmount Computer includes a solid state hard drive loaded with the Microsoft Windows

More information

Provides one channel for Ethernet over existing

Provides one channel for Ethernet over existing LB304A LBPS301A LBPS304A Hardened Ethernet Extender Quick Start Guide Provides one channel for Ethernet over existing voice-grade copper twisted-pair wire. copper BLACK wire. BOX Customer Support Information

More information

sigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES

sigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS Enhanced defect detection Built-in diagnostics for press machinery Quicker setup and easier maintenance than competitive systems Lowest monitoring cost per

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

S-series DC to DC Power Supply

S-series DC to DC Power Supply January 2013 Page 1 The DeltaV S-series DC/DC system power supplies are modular, easy to install, and secure Easy to use Flexible and cost-effective Secure Simplified system power Introduction Power your

More information

Optimize your simple machines... Modicon M218 Selection Guide

Optimize your simple machines... Modicon M218 Selection Guide Optimize your simple machines... Modicon M218 Selection Guide Compact Solution for Simple Machines Optimized Logic Controller Modicon M218 With intelligent software platform, specialized functional s,

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. 56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING

More information

Philips remote monitoring and control systems

Philips remote monitoring and control systems Philips remote monitoring and control systems Intelligent management of your road and street lighting Energy cost savings Maintenance efficiencies Reduced CO 2 emissions Improved safety Minimized light

More information

High Availability and Safety solutions for Critical Processes

High Availability and Safety solutions for Critical Processes High Availability and Safety solutions for Critical Processes An Introduction to AADvance Subrahmanya Bhat P Sr. Systems Engineer 09 & 10 th Sep 2014 PUBLIC INFORMATION Rev 5058-CO900E 2 Agenda Process

More information

DeltaV SISnet Repeater

DeltaV SISnet Repeater September 2013 Page 1 The DeltaV SIS platform is the world s smart SIS system to use the power of predictive intelligence for increasing the availability of the entire safety instrumented function. Fiber-optic

More information

Cisco Communication Media Module

Cisco Communication Media Module Cisco Catalyst 6500 Series and Cisco 7600 Series Communication Media Module Product Overview Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility

More information

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System RTM X42 is an innovative system that utilizes force measuring rollers to capture the tension of individual wires or strands,

More information

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System Data Sheet FUJITSU Storage ETERNUS LT260 Tape System Data Sheet FUJITSU Storage ETERNUS LT260 Tape System Easy Scalable Tape Automated Solution for up to 3.5 PB of Data ETERNUS LT TAPE STORAGE SYSTEM The

More information

Power network telecommunication

Power network telecommunication www.siemens.com Power network telecommunication Teleprotection Answers for infrastructure and cities. Binary I/O The best protection against high-voltage grid failures When it comes to managing power networks,

More information

Station Automation Series COM600 Protection and control from ABB Future-proof Concept: Extensive Substation System Integration and Interoperability The Station Automation Series COM600 is a dedicated system

More information

SAN Conceptual and Design Basics

SAN Conceptual and Design Basics TECHNICAL NOTE VMware Infrastructure 3 SAN Conceptual and Design Basics VMware ESX Server can be used in conjunction with a SAN (storage area network), a specialized high speed network that connects computer

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8 Type code Ident no. 1545007 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm Cable max. 50 m between interface and read/write head 2 decimal rotary coding switches for the adjustment

More information

Wireless Field Data Backhaul

Wireless Field Data Backhaul October 2014 Page 1 Smart Wireless Gateway 1552WU An Emerson Smart Solution integrates WirelessHART data from remote areas of your plant. Scalable Reduced cost Safer deployment Secure and reliable communications

More information

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing

More information

Power over Ethernet technology for industrial Ethernet networks

Power over Ethernet technology for industrial Ethernet networks Power over Ethernet technology for industrial Ethernet networks Introduction Ethernet networking has grown beyond office and home usage to become a very successful protocol suite used in many industrial

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

DCS Data and communication server

DCS Data and communication server 8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With

More information

Series Six Plus Programmable Controller

Series Six Plus Programmable Controller Series Six Plus Programmable Controller Gl?K-0147B June 1989 Central Processor Unit 8-Slot Rack 1l-Slot Rack General Description The Central Processor Unit (CPU) for the Series Six Plus Programmable Logic

More information

UNIVERSAL TRAFFIC CONTROLLER

UNIVERSAL TRAFFIC CONTROLLER Eventueel subtitel Eurocontroller EC-2 UNIVERSAL TRAFFIC CONTROLLER EuroController EC-2 The Peek EuroController EC-2 is a state-of-the-art traffic controller, rooted in a long tradition of innovation and

More information

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER Understanding what a PAC is starts from the understanding of PLC. A PLC is a Programmable Logic while

More information

FM4100 USER MANUAL V1.4

FM4100 USER MANUAL V1.4 FM4100 USER MANUAL V1.4 Table of Contents ATTENTION!... 2 INSTRUCTIONS OF SAFETY... 3 LEGAL NOTICE... 4 Short description...5 1.1 About the document... 5 1.2 Acronyms... 5 1.3 Mounting guidelines... 5

More information

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS

More information

WANic 800 & 805. 1 or 2 HSSI ports Up to 52 Mbps/port. WANic 850 & 855. 1 or 2 T3 or E3 ports Full-speed CSU/DSU. WANic 880.

WANic 800 & 805. 1 or 2 HSSI ports Up to 52 Mbps/port. WANic 850 & 855. 1 or 2 T3 or E3 ports Full-speed CSU/DSU. WANic 880. WANic P C I S O L U T I O N S WANic PCI cards are high-performance synchronous WAN adapters for use in standard Linux PCs and Industrial Series routers from ImageStream. WANic adapters include one, two,

More information

MITRAC 1000. Driven by Reliability. Propulsion & Controls

MITRAC 1000. Driven by Reliability. Propulsion & Controls MITRAC 1000 Driven by Reliability Propulsion & Controls MITRAC Medium Power exceeding your expectations The BOMBARDIER* MITRAC* 1000 product portfolio is a family of propulsion systems for a wide range

More information

StruxureWareTM for Buildings

StruxureWareTM for Buildings StruxureWareTM for Buildings Next generation intelligent Building Management System (ibms) Product Catalogue Make the most of your energy Plan for the future while protecting your past investments. 03

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server Advanced Blade Ecosystem the ideal platform for branch offices and mediumsized companies Fujitsu PRIMERGY BX Blade Servers meet all the requirements of

More information

TK800-Series Industrial GPRS / UMTS / LTE Router

TK800-Series Industrial GPRS / UMTS / LTE Router The new generation LTE with 100 Mbps LTE standard for high transmission rates and good network coverage in sparsely populated areas Dynamic Multipoint VPN GRE, L2TP, IPSec, DMVPN, OpenVPN Simple and fast

More information

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet switch Supports 10 Mbps/100 Mbps 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection 7/8" males, 5-pin, for power supply Separated power

More information

Early Warning Fire Detection and Integrated Security Solution. System Overview

Early Warning Fire Detection and Integrated Security Solution. System Overview Early Warning Fire Detection and Integrated Security Solution System Overview The FirePosse Early Warning Fire Detection and Integrated Security System from Firebreak Canada Corp. represents a major advance

More information

print close Building Blocks

print close Building Blocks print close Machine Design Kim Hartman Wed, 2015-07-15 11:23 Many OEMs strive to maximize plant productivity by allowing machines to perform multiple operations simultaneously. Some of these concurrent

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application Product overview brochure ABB Medium Voltage Products Our one-stop approach for every medium voltage application Overview ABB meets every need for reliable, safe and energy-efficient medium voltage switchgear,

More information

The Intel NetStructure SIU520 Signaling Interface

The Intel NetStructure SIU520 Signaling Interface The Intel NetStructure SIU520 Signaling Interface Intel in Communications The Intel NetStructure SIU520 signaling interface unit (SIU) provides Signaling System 7 (SS7) connectivity for multichassis call

More information

Safety compliance. Energy management. System architecture advisory services. Diagnostics. Network topologies. Physical and functional partitioning

Safety compliance. Energy management. System architecture advisory services. Diagnostics. Network topologies. Physical and functional partitioning Energy management Network topologies Physical and functional partitioning Safety compliance Diagnostics System architecture advisory services www.continental-corporation.com Why system architecture? 2

More information

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring LNG Monitoring Fiber-Optic Leakage Detection System Pipeline leakage detection Regasification and liquefaction monitoring Tank annulus and base slab monitoring Spill containment control Intelligent Solutions

More information

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use SNMP-1000 Intelligent SNMP/HTTP System Manager Features Monitors system fans, temperature, voltage, power supply, CPU fan, CPU temperature, Vcore, watchdog timer etc. Stand alone system monitoring, no

More information