1 CONCENTO PLUS System Description COMMUNICATION IN PERFECTION For nursing homes and assisted living Safety in accordance with DIN VDE 0834 Part 1 and 2

2 This manual was compiled with great care and all the information it contains has been checked for correctness. However, no liability can be accepted for incorrect or incomplete information. All rights reserved, particularly those relating to copying and dissemination. No part of the documentation may be reproduced or electronically processed, copied or disseminated without the prior written permission of Tunstall GmbH. We reserve the right to make technical changes. We reserve the right to make content changes. Tunstall GmbH

3 Contents 1. Performance features Functions Staff presence registration Call types and priority levels Signalling in the room Signalling on room lamps Signalling on corridor displays Signalling on room terminals Initiating a call Handling a call with speech Handling a call without speech Speaking to staff Announcements Timezones / group coupling Telephone connection Telephone connection possibilities Handling a call on the telephone Configuration Added flexibility Alias texts for room names Specified times / timeouts Different call types Flexible inputs on the room terminals The technology System overview System structure Physical and logical groups Cables System limits ConLog PLUS Management Software Telephone connection ConLog PLUS Management Software System security Reaction of the nurse call system to failures Nurse call system fault displays

4 8. Room types Cables legend Patient / resident room Staff room Function room Ward bathroom WC with multiple cubicles Lounge / dining room Apartment in assisted living Accessories required Product overview Room terminals Room lamps, corridor displays Switches Call switches with connection socket Plug-in call devices for connecting to connection socket Wireless call devices Wired call devices Software and PC System control Power supply units Frames and back boxes Index

5 1. Performance features CONCENTO PLUS is a light call and communication system for nursing homes, retirement homes, apartment buildings, assisted living and hospitals, conforming to DIN VDE 0834, 04/2000, Part 1 and Part 2. It is the further development of the successful Concento system. A complete system solution is now available that can be seamlessly integrated into modern communications landscapes. 1.1 Advantages to nursing organisation CONCENTO PLUS supports efficient care organisation via the flexible assignment of wards and individual adaptation to the nursing situation. Coupling of groups, manually or with time control, organised in up to 9 different shifts. Freely programmable night-time switchover to external Telecare Control Centres or telephones. Internationally comprehensible symbols on all equipment. Easy readable plain text displays, texts can be configured for specific projects. State-of-the-art speech technology for system-wide communication with duplex speech, several speech channels for flexible use. System extension with radio-based call devices for increasing security for residents/patients and staff. Staff can be contacted at all times thanks to the inclusion of mobile telephone solutions for displaying and dealing with calls. Synthetic voice announcements when connecting to telephone systems. Logging and documentation of all system events in the ConLog PLUS management software Added flexibility A system platform for retirement homes, nursing homes, assisted living and hospitals. Complete system solutions for applications with and without speech. Future-proof thanks to readiness for additional functions via the existing system infrastructure for all bus components in the event of organisational and building changes. A selection of various switch ranges is available for adapting to the architectural design Advantages for installation Standard installation material, no special system cables required. 3

6 1. Performance features Flexibility thanks to the management interface with open interfaces for communicating with external systems such as telephone systems. Simple system updating via central programming, maintenance and configuration with the modern management and configuration tool ConLog PLUS management software. Low-cost thanks to optimum compatibility with previous system generations and low installation costs thanks to the use of standard materials Operational reliability advantages Maximum operational reliability in accordance with DIN VDE 0834 thanks to an independent cable and transmission network and permanent function monitoring. Maximum functional reliability thanks to a modular system structure with decentralised control Example ward An example ward is shown on the following page Key to symbols Room lamp Corridor display Terminal SD6 P Call switch with connection socket Display module Pear push switch Pull cord switch Pneumatic switch Call switch Call & Cancel switch/wc Group electronic Power supply unit 4

7 1. Performance features RM R104 5

8 1. Performance features 6

9 2. Functions 2.1 Staff presence registration One important prerequisite for correct operation of the system is the registration of presence by the staff. All rooms in which nursing staff can be present are equipped with green presence buttons in the entrance area. When entering the room, the staff activate presence and deactivate it again when they leave Activated presence Indicates the location of staff. Prepares for the reception of forwarded calls. Prepares the room for raising emergency calls. This means that calls from rooms with activated presence are signalled with higher priority. Prepares the Terminal SD6 P for raising an alarm call. Pressing a special key combination on the terminal SD6 P raises a highest-priority call, i.e. an alarm call, when presence is activated. Calls are cancelled by the activation or later deactivation of presence (exception: calls in the WC) Presence buttons Green presence buttons are available integrated into all room terminals, i.e. terminals, call/presence combination bus (RAB) and display module. The terminal SD6 P ( ) provides presence buttons for two groups of staff: Presence 1 (green button): Nursing staff Presence 2 (yellow button): Nursing staff 2 or doctor. 7

10 2. Functions Terminal SD6 P ( ) Terminal S4 P ( ) Terminal S4 B ( ) Presence button 1, green 2 Presence button 2, yellow 3 Reminder light Display module ( ) Call/presence combination bus (RAB) ( ) Fig. 1: Presence buttons in the room terminals Indicating presence The reminder light in the presence button glows when presence is activated. The green light section of the room lamp in the corridor lights up. Room lamp universal, 3 sections ( ) 8

11 2. Functions 2.2 Call types and priority levels The purpose of a call is to summon help by patients, staff or automatically via sensors. Depending on the call event, a distinction is made between different call types, and these in turn are assigned to call categories. Call types are divided up into priority levels. This ensures that highest priority calls are always in the foreground of the equipment displays and are therefore dealt with first. CONCENTO PLUS has 30 priority levels. Call category Call type Call event Calls (low priority) Emergency calls (medium priority) Alarm calls (highest priority) Room call Call Bed (= bed call) WC call Emergency call 1 Emergency call2 Emergency call Bed Emergency call WC Alarm call The call switch on the room terminal (terminal, RAB, display module) was pressed. A call button on the bed (e.g. pear push switch) was pressed or the plug of a plug-in call device (e.g. pear push switch) on the bed was pulled out of the socket (disconnection call). A call switch was pressed in the WC room. A room call was raised with Presence 1 activated. A room call was raised with Presence 2 activated (only possible in rooms with Terminal SD6 P). A bed call was raised with Presence activated. A WC call was raised with Presence activated. A special call device was triggered or a special button combination on Terminal SD6 P was pressed in order to summon specialist staff (e.g. resuscitation team). Other call types can also be used if necessary. Examples: Fire alarm: Smoke detector signals the presence of smoke. Diagnostic call: A medical monitoring device has raised a call. Inactivity alarm Resident was not active for extended period. Telephone call: Automatically raised call when there is a telephone call in a staff room while Presence is deactivated. 9

12 2. Functions 2.3 Signalling in the room Location light Call buttons have location lights, i.e. a light indicator for locating the call switch in the dark Reassurance light Call buttons have reassurance lights, i.e. a light indicator showing that a call was raised from this call device in order to reassure the patient Reminder light Presence buttons and WC cancel buttons have reminder lights that indicate the actual status of the button and so serve as a reminder to reset the button. 10

13 2. Functions 2.4 Signalling on room lamps Red: Call Green: Presence White: Call location = WC Fig. 2: Room lamps The call category is shown in the red light section of the room lamp: Call category Calls: Continuous light. Call category Emergency calls: Flashes (1 sec. / 1 sec.). Call category Alarm calls: Flashes quickly (0.3 sec. / 0.3 sec.). The white light section also glows when a call is made from WC rooms (WC call, Emergency call WC). The presence of staff is indicated in the green light section of the room lamp by a continuous light. NOTE! The oldest call of the highest priority is displayed if there are several calls simultaneously. 11

14 2. Functions 2.5 Signalling on corridor displays Corridor displays are available in the following versions: 8-digit, single-sided: digit, double-sided: digit, single-sided: digit, double-sided: On the corridor displays, calls are displayed as follows with the call type and call location: RM R104 Call type, 3-digit Call location, 4-digit e.g. room no. Fig. 3: Information on the 8-digit corridor display ROOM R104 Mayr Call type, 6-digit Call location, 9-digit e.g. room type and room no. Fig. 4: Information on the 16-digit corridor display The oldest call of the highest priority is displayed if there are several calls. Presences are displayed if there is no call. If there is no message, the time is displayed centred. 12:07 12:07 Fig. 5: Display of the time with the corridor display in resting state 12

15 2. Functions Refer to the table below for the abbreviations for the call types that are used in the corridor displays and also on the Terminal SD6 P and display module): Abbreviations for call types in the corridor displays, Terminal SD6 P and display module Priority Call type 8-digit corridor display Presence Staff Presence 1 ST1 STAFF1 Staff Presence 2 ST2 STAFF2 Staff Presence ST12 STF1/2 16-digit corridor display, Terminal SD6 P, display module Calls (low priority) Emergency calls (medium priority) Alarm calls (highest priority) Room call R-R ROOM Call Bed B BED WC call WC WC CALL Emergency call 1 E1 EMER 1 Emergency call 2 E2 EMER 2 Emergency call Bed EB EMER B1... B4 Emergency call WC EWC EME WC Alarm call ALM ALARM 13

16 2. Functions 2.6 Signalling on room terminals Room terminals are: Terminal SD6 P: Terminal S4 P: Terminal S4 B: Display module: Call/presence combination bus (RAB): Into rooms where presence is activated, calls are forwarded. This means that the calls are displayed on the room terminals of the rooms in which staff are present Audible call indication Forwarded calls are indicated audibly on all room terminals. The higher the call's priority, the faster the tone sequence of the call tone. Priority Call tone Call tone sequence Calls (low priority) Emergency calls (medium priority) Alarm calls (highest priority) Room call Call Bed WC call Emergency call 1 Emergency call 2 Emergency call Bed Emergency call WC Alarm call 1 sec. tone / 10 sec. pause 1 sec. tone / 1 sec. pause 0.3 sec. tone / 0.3 Sec. pause 14

17 2. Functions What is shown in the display The Terminal SD6 P and the display module have an 8-digit, 2-line display. In the display, calls are displayed as follows with the call type and call location: Call type, 6-digit (Display same as the 16-digit corridor display) Number of other messages in the background, 2-digit ROOM 3 R104 May Call location, max. 25-digit e.g. room no. and room type (more than 8 characters as ticker-type text) Fig. 6: What is shown in the display of Terminal SD6 P or display module The oldest call of the highest priority is displayed if there are several calls. The number of all other calls, presence registrations and any nurse call system faults is displayed at the top right. On the Terminal SD6 P, the oldest call with the highest priority is shown first. However, it is also possible to scroll through all other calls, presence registrations and any nurse call system faults with the double-arrow button (remote cancel button). On the display module, the highest-priority call is shown for 15 seconds. Next, all other calls, presence registrations and any nurse call system faults are scrolled through according to their priority, i.e. each is displayed for 5 seconds. If there is no message, the time is shown on Terminal SD6 P and on the display module. The active timezone (see Page 20) is also shown on Terminal SD6 P. Active timezone Fig. 7: CONCENTO 1 12:07 Time CONCENTO 12:07 Time Display of Terminal SD6 P or display module in resting state 15

18 2. Functions 2.7 Raising a call The call buttons of the CONCENTO PLUS devices are red and are marked with a nurse symbol. Pressing a call button raises a call. Call buttons are available integrated into the room terminals and the pear push switches, but also individually offset as call switches. Call switches actuated by pulling or with pneumatic actuation are also available. Room terminals Pear push switches Call switch with connection socket(s) Call switch Call & Cancel switch/wc Pull cord switch Pneumatic call switch Fig. 8: Call devices 16

19 2. Functions 2.8 Handling a call with speech The terminals of the CONCENTO PLUS nurse call system are equipped for speech communication and therefore allow calls to be answered with a duplex speech connection to the call location Call indication Calls are indicated on all terminals where presence is activated. However, on Terminal S4 P and Terminal S4 B, they are indicated only audibly via a call tone. On Terminal SD6 P, the calls are also shown visually on the display Answering a call with speech possibility 1. Pressing the answer button (loudspeaker) makes a speech connection to the call location. This is a high-quality duplex speech connection. The staff talk to the person seeking help. 2. In order to terminate the speech connection the answer button (loudspeaker) is pressed again. The call is parked. Bed calls, room calls and inactivity alarms can be remotely cancelled if there is no need to go to the call location. The remote cancel button (double arrow) is pressed instead of the answer button (loudspeaker). 3. Staff go to the call location and attend to the person seeking help. 4. The calls are automatically cancelled at the call location when presence is activated or deactivated. Exception: WC calls and WC emergency calls must be cancelled by pressing a grey WC cancel button in the WC room Calls without speech possibility In the following cases, one cannot make a speech connection to the call location: No speech device at the call location. This means the room terminal is a RAB or the display module. Call was raised in the WC (WC call, Emergency call WC). The speech line is engaged. If the answer button (loudspeaker) is pressed in these cases in order to answer the call, a warning tone is sounded. The staff must go to the call location and attend to the person seeking help. The calls are automatically cancelled at the call location when presence is activated or deactivated. Exception: WC calls and WC emergency calls must be cancelled by pressing a grey WC cancel button in the WC room. 17

20 2. Functions 2.9 Handling a call without speech The display module and the call/presence combination bus (RAB) are not equipped for speech communication. They indicate calls when presence is activated. On the display module, the calls are shown visually in the display and are indicated audibly by a call tone. On the RAB, the calls are indicated only audibly by a call tone. When a call is indicated, the staff must go to the call location and attend to the person seeking help. The calls are automatically cancelled at the call location when presence is activated or deactivated. Exception: WC calls and WC emergency calls must be cancelled by pressing a grey WC cancel button in the WC room Speaking to staff On Terminal SD6 P, the indication of presence can be used to speak to staff by calling up the registration of presence and, by pressing the answer button (loudspeaker), making a speech connection to the location of the staff. 18

21 2. Functions 2.11 Announcements Announcements can be made from a Terminal SD6 P, which has been set on the equipment to the Staff room type. The following announcement destinations are possible: Announcement to all rooms on your own ward and the wards coupled to your own ward, where Staff Presence 1 is activated. Announcement to all rooms on your own ward and the wards coupled to your own ward, where Staff Presence 2 is activated. Announcement to all rooms on your own ward and the wards coupled to your own ward, where Staff Presence 1 or 2 is activated. Announcement to all rooms on your own ward and the wards coupled to your own ward. Announcement to all rooms on a selected ward. 19

22 2. Functions 2.12 Timezones / group coupling The nurse call system adapts itself to the institution's shift system. The staff's area of responsibility often changes in the various shifts. Whereas the staff is responsible for one ward during the day for example, the night shift is often responsible for the entire building. The nurse call system is organised so that all calls of this area of the staff's responsibility are displayed in the staff's respective area of responsibility. Organisation is based on timezones. The system administrator can set up as many as 9 different timezones per nurse call system. The staff's area of responsibility for this time is stored for each timezone. The area of responsibility defines which wards (= logical) groups are coupled during this timezone. Example: Timezone Designation Areas of responsibility 1 Mon Fri early shift Ward 1 independent Ward 2 independent Ward 3 independent Ward 4 independent 2 Mon Fri late shift Ward 1 coupled with 2 Ward 3 coupled with 4 3 Mon Fri night shift Wards 1, 2, 3 and 4 coupled 4 Saturday early shift Ward 1 independent Ward 2 independent Ward 3 independent Ward 4 independent 5 Saturday late shift Ward 1 independent Wards 1, 2, 3 and 4 coupled 6 Saturday night shift Wards 1, 2, 3 and 4 coupled 7 Sunday early shift Ward 1 coupled with 2 Ward 3 coupled with 4 8 Sunday late shift Wards 1, 2, 3 and 4 coupled 9 Sunday night shift Wards 1, 2, 3 and 4 coupled Depending on the nurse call system setting, the timezones are either changed with time control (automatically) or the staff change the timezones manually on a special Terminal SD6 P (setting staff room with HAB ). 20

23 3. Telephone connection The CONCENTO PLUS nurse call system calls can be forwarded to telephones or telephone systems in parallel to their local display on room terminals and corridor displays. Telephones can be used, for example, as DECT devices for handling calls locally, or can be carried as mobile phones for being available on call. The CONCENTO PLUS nurse call system calls can also be forwarded to a professional Telecare Control Centre PNC or WILMA, e.g. at night when there are no staff on location. 21

24 3. Telephone connection 3.1 Telephone connection possibilities Text display & synthetic voice announcement & call handling When a call is raised, a text message is shown inthe telephone's display and the telephone then rings. Room Call Room 201 ROOM R. 201 The user picks up the receiver and hears a synthetic voice announcement stating the call type and call location and assisting the user. The user presses a key to make a speech connection to the call location. The user can remotely cancel some call types by telephone. For others, the user must go to the call location. For precise details, see Chapter Synthetic voice announcement & call handling Room Call Room 201 The telephone rings when a call is raised. The user picks up the receiver and hears a syntheticvoice announcement stating the call type and call location and assisting the user. The user presses a key to make a speech connection to the call location. The user can remotely cancel some call types by telephone. For others, the user must go to the call location Text display, no call handling ROOM R. 201 When a call is raised, a text message is shown in the telephone's or pager's display. A speech connection cannot be made. It is necessary to go to the call location Telecare Control Centre The Telecare Control Centre (PNC or WILMA) is called when a call is raised. A member of the centre's staff takes the call like an emergency call from an emergency telephone. The resident's personal data is visible on the PC. A speech connection to the call location is established. The staff member can remotely cancel some call types by telephone. For others, someone must go to the call location. 22

25 3. Telephone connection 3.2 Handling a call on the telephone Procedure for a call with speech possibility 1. The call type and call location are shown in the display. The telephone then rings. ROOM R Pick up the receiver. 3. The voice announcement runs and is repeated continuously. Room Call. Room 104. Please press the 4 key.. ROOM R Press the 4 key. The speech connection is established. 5. Talk to the person seeking help. 6. Press the 0 key to end the discussion. 5. Put down the receiver. 7. Go to the call location and attend to the person seeking help. Cancel the call. Note: In the case of a bed call, room call or inactivity alarm, the call is remotely cancelled when the speech connection is terminated. Therefore, it is only necessary to go to the call location if further assistance is needed there. While the speech connection is established, it is possible to switch over to manual speech direction control if the automatic speech direction control is not working sufficiently due to loud background noises. 7 key: The person on the telephone speaks. The person at the call location can only hear. 8 key: The person at the call location speaks. The person on the telephone can only hear. 4 key returns you to automatic speech direction control. The talk time is limited (depending on the setting: between 1 and 10 min.). Pressing the 4 key extends the speech duration by this same length of time. 23

26 3. Telephone connection Pressing the 2 key allows a call to be declined after the voice announcement has been heard. The next configured telephone is then called Procedure for a call without speech possibility Calls without a speech possibility, e.g. WC calls, WC emergency calls or calls from rooms with a call/presence combination bus (RAB) or display module are displayed on the telephone. However, it is not possible to talk to the person at the call location. It is therefore necessary to go to the call location. 1. The call type and call location are shown in the display. The telephone then rings. WC CALL R Pick up the receiver. 3. The voice announcement runs. WC Call. Room 104. Please press the 0 key. WC CALL R Press the 0 key. 5. Put down the receiver. 6. Go to the call location and attend to the person seeking help. Cancel the call. 24

27 3. Telephone connection 3.3 Configuration Which telephone is called when which call is made and at what time is set via configuration in the ConLog PLUS Management Software. For each ward (= logical group), the telephone that is called when there is a call in the nurse call system is defined for each shift (= timezone). For this, it is possible to save a call order in case the call is not answered and must be forwarded. e.g. early shift Mon - Fri Ward 1 Call If Tel. 1 does not answer the call. If Tel. 2 does not answer the call. Telephone 1 Telephone 2 Telephone 3 Ward 2 Call If Tel. 2 does not answer the call. If Tel. 3 does not answer the call. Telephone 2 Telephone 3 Telephone 1 Ward 3 Call If Tel. 3 does not answer the call. If Tel. 2 does not answer the call. Telephone 3 Telephone 2 Telephone 1 e.g. night shift Mon - Fri Ward 1 Call If Tel. 1 does not answer the call. Telephone 1 Telephone 4 Ward 2 Call Telephone 1 If Tel. 1 does not answer the call. Telephone 4 Ward 3 Call Telephone 1 If Tel. 1 does not answer the call. Telephone 4 25

28 3. Telephone connection 26

29 4. Added flexibility CONCENTO PLUS meets the strict requirements of the German standard DIN VDE 0834, but at the same time the system displays enormous flexibility that allows it to be optimally adapted for any application. This chapter is intended to give you an insight into the flexibility of CONCENTO PLUS. 4.1 Alias texts for room names In the nurse call system, every room is unambiguously identified by a 4-digit room number, a 2-digit physical group number and a 3-digit logical group number. However, in order to better identify the room, a maximum 25-digit alias text can be saved for each room, i.e. for each room terminal. When a call is raised, this is displayed on the SD6 P Terminals and on the display modules. Shorter texts for showing on the corridor displays can also be saved. NOTE! Texts that can be entered freely are referred to in the CONCENTO PLUS system alias texts. 27

30 4. Added flexibility Call information on the Terminal SD6 P and display module The following example is for Room Call, Room 104. Call type, 6-digit (Display same as the 16-digit corridor display) Number of other calls, presences and faults in the background, 2-digit ROOM Logical group, 3-digit Room No., 4-digit Fig. 9: Information on the terminal SD6 P or display module without alias text Call type, 6-digit (Display same as the 16-digit corridor display) Number of other calls, presences and faults in the background, 2-digit ROOM 3 R104 May Alias text, 25-digit (more than 8 characters as ticker-type text) Fig. 10: Information on the terminal SD6 P or display module with alias text If necessary, an alias text for the room and the respective call input of the device can be saved and displayed for the Terminal SD6 P and display module, e.g. R104 May. 28

31 4. Added flexibility Showing a call on corridor displays The following example is for Room Call, Room 104 : Display on the 8-digit corridor display: RM 0104 Call type, 3-digit Room No., 4-digit Display on the 16-digit corridor display: ROOM Call type, 6-digit Logical group, 3-digit Room No., 4-digit Fig. 11: Display on the corridor displays without alias text Display on the 8-digit corridor display: RM R104 Call type, 3-digit Alias text, 4-digit Display on the 16-digit corridor display: ROOM R104 May Call type, 6-digit Alias text, 9-digit Fig. 12: Display on the corridor displays with alias text 29

32 4. Added flexibility 4.2 Specified times / timeouts Certain times known as timeouts are defined in order to ensure a smooth, reliable and effective sequence of events in the nurse call system. These times can be adapted to the institution's nursing organisation. Settable time Meaning Setting possibility Call overflow time Fresh call time period Talk time Call Delay Telephone Call Delay DECT Call Retransmission If a call is not answered within a certain time, it is displayed in all of the institution's wards. If a parked call (i.e. the speech connection to the call location has been closed without the call being cancelled) is not cancelled at the call location after the set time, a fresh call is raised. When a speech connection continues for longer than the set time, it is interrupted. This applies to: - Answering a call at the terminal - Answering a call on the telephone - Announcements The time between call initiation and the telephone call. The calls are displayed immediately on corridor displays and room terminals. The time between call initiation and displaying the text on the DECT telephone display. Call re-sent to pager if the call has not yet been cancelled. Settable: minutes Factory setting: 5 minutes Note: The call overflow can be deactivated. Settable: minutes Factory setting: 5 minutes Settable: minutes Factory setting: 2 minutes Note: When a call is answered on the telephone, the time can be expended by pressing a key. Settable: minutes Factory setting: 0 minutes Settable: minutes Factory setting: 0 minutes Settable: minutes Factory setting: 9 minutes 30

33 4. Added flexibility 4.3 Different call types So that call events can be reported as precisely as possible, it is possible to select from a list of more than 40 predefined call types. Additionally, new call types can be defined by a nurse call systems expert. Selection examples include a call in the event of an attack, intruder, too high room temperature or too low room temperature. A service call can be used for simple things such as ordering coffee. Technical alarms can also be reported in this manner, e.g. heating or air-conditioning system failure. For each call type, the following parameters are defined and can be changed if necessary: Text for displaying the call type on various devices Call tone for call type display Priority for call type display Is the call type answerable? This means, can a speech connection be established to the call location? Can the call type be cancelled remotely? This means, may the call be cancelled remotely after a speech connection without staff attending the call location? When setting these parameters, it should be ensured that the regulations of DIN VDE 0834: Part 1 are adhered to Preset call types Alarm calls Emergency calls (Normal) calls Alarm call Emergency call 1 Room call Fire Emergency call 2 Bed Fire alarm Emergency call Bed WC call Temperature Emergency call WC Inactivity alarm Diagnostic Emergency call Radio Propane Methane Service Door alarm Intruder Attack Telephone call Radio alarm Radio External alarm Fall Water 31

34 4. Added flexibility 4.4 Flexible inputs on the room terminals The room terminals are equipped with numerous inputs for additional call connections. Many of these inputs are freely configurable. In practical terms, the call type is freely selectable (selection from over 40 call types, see Page 31). The contact type (NO or NC contact) can be set. On the terminals it is even possible to choose between a static (trigger impulse) and dynamic (trigger duration) call, e.g. for messages from the fire alarm system RAB and display module inputs Input Call type NC/NO contact Static / dynamic Factory setting Factory setting Factory setting R1 Bed 1 yes NO contact yes static no R2 Bed 2 yes NO contact yes static no R3 Bed 3 yes NO contact yes static no R4 Door alarm yes NO contact yes static no WR WC call button no NO contact no static no WA WC cancel button no NO contact no static no changeable changeable changeable The inputs on the display module can be set on the device itself. The inputs on the call/presence combination bus (RAB) can only be set via a separate service module by a call system specialist Inputs on the Terminals Input Call type NC/NO contact Static / dynamic Factory setting changeable Factory setting R1 Bed 1 yes NO contact yes static yes R2 Bed 2 yes NO contact yes static yes R3 WC call yes NO contact yes static yes R4 WC cancel button yes NO contact yes static yes R5 Fire yes NO contact yes dynamic yes R6 Door alarm yes NO contact yes static yes R7 Door alarm yes NO contact yes static yes Factory setting changeable changeable The inputs on the Terminal SD6 P can be set on the device itself. The inputs on the Terminal S4 B and Terminal S4 P can only be set via a separate service module by a call system specialist. 32

35 5. The technology 5.1 System overview Technical room analog a/b Ward 2 Technical room analog a/b Ward 1 Central technical room ESPA Paging/DECT LAN LAN for remote maintenance Fig. 13: System overview 33

36 5. The technology 5.2 System structure Ward bus Physical group 2 Group electronic Secondary lines Secondary lines Room 1 Room 2 Group bus Group electronic Ward bus Physical group 1 Secondary lines Secondary lines Room 1 Room 2 LAN LAN for remote maintenance ESPA Paging/ DECT Fig. 14: System structure The CONCENTO PLUS nurse call system is controlled decentrally via group electronics. Each group electronic controls a ward bus, i.e. a physical group. The nurse call system is based on a bus system that is comprised of a group bus and ward buses. The group bus interconnects all group electronics, the management interface and the fire alarm interface of the nurse call system. The ward bus is connected to a group electronic and connects all room terminals of a physical group to each other: Terminal SD6 P, Terminal S4 P, Terminal S4 B, display module, call/presence combination bus (RAB) and management interface. The room terminals control the devices inside a room. The devices are connected to the room terminal in a star or line configuration as secondary lines. The management interface provides interfaces to external systems. It is connected to the group bus or the ward bus, depending on the application. The management interface provides interfaces to the following systems: a/b interface to telephone systems, ESPA interface to DECT or pager systems and a network access for service access via FTP. CONCENTO PLUS ' own ConLog PLUS management software is also connected to the management in 34

37 5. The technology terface via an RS232 interface. The entire nurse call system is configured via the ConLog PLUS management software. The system's power supply is provided via decentrally installed power supply units. The number and installation location of the power supply units depend on the respective power requirement Speech communication Speech communication and data transfer are separate from each other. This means that nurse call systems are possible with or without speech communication.mixed operation is possible with no problem. The speech line connects the system's own speech devices: Terminal SD6 P Terminal S4 P Terminal S4 B. One speech channel is available for each physical group. Besides speech communication within the nurse call system, speech communication via telephone devices connected to the CONCENTO PLUS nurse call system via the analog a/b interface of the management interface is also possible, see from Page

38 5. The technology 5.3 Physical and logical groups Logical group 5 e.g. ward 5 Logical group 3 e.g. ward 3 Logical group 1 e.g. ward 1 Logical group 6 e.g. ward 6 Logical group 4 e.g. ward 4 Logical group 2 e.g. ward 2 Physical group 3 Physical group 2 Physical group 1 Organisation of the nursing home CONCENTO PLUS technology When CONCENTO PLUS was developed, the organisational structure of the institution was completely separated from the technical structure. An organisational unit refers to a number of rooms for which the same staff are responsible. In most cases this is a ward. The organisational unit is referred to as a logical group. Most logical groups are wards. A physical unit refers to a number of rooms that are connected to a ward bus and that are controlled by a group electronic. The physical unit is referred to as a physical group. A physical group can consist of several logical groups. A logical group can even be divided between several physical groups. This separation between the organisational and physical structures means that the number of group electronics required can be significantly reduced: The number of group electronics and physical groups required is not defined by the number of logical groups (e.g. wards), but instead depends on the building structure and the desired reliability. The independence of the physical structure from the organisation also has the advantage that when the cables and equipment are being planned, there is ially no need to take account of the organisation form that will be required later. The organisation of the system can be changed at any time, irrespective of the physical structure. Logical group = organisational unit = in most cases: Ward Physical group = physical unit 36

39 5. The technology 5.4 Cables Standard telecommunications cables IY(ST)Y... are used for the group bus, the ward buses and the secondary lines. The power supply for all components is in accordance with DIN VDE 0834 established via a separate cable network (ring) by using standard cables, e.g. NYM 2 x 2.5 mm 2. On average, one power supply unit is required for each ward bus. 5.5 System limits Group bus Maximum cable length of the group bus: 700 m Maximum 40 users per group bus, consisting of: Group electronics, management interface, fire alarm interface. Maximum 1 management interface per group bus. Maximum 1 fire alarm interface per group bus Ward bus Maximum cable length of each ward bus: 700 m Maximum 40 users per ward bus, consisting of: Terminals SD6 P, Terminals S4 P, Terminals S4 B, display module, call/presence combination bus (RAB), corridor displays, management interface. Maximum 1 management interface per ward bus Secondary lines Maximum of 4 monitored devices on one secondary line. Maximum cable length per secondary line: 20 m. 37

40 5. The technology 5.6 ConLog PLUS Management Software The purpose of the ConLog PLUS management software is the central configuration and programming of CONCENTO PLUS nurse call systems, and the logging and evaluation of all system events of these nurse call systems. The PC with ConLog PLUS is connected to the nurse call system via the management interface on the group bus. ConLog PLUS can be operated as a stand-alone solution or in the network (client/ server structure). One server license ( ) is required for each nurse call system. A client license ( ) is required for each additional workstation. Remote maintenance PSTN ISDN Management Interface Server Length: 3 m Group bus of the nurse call system LAN / Ethernet Client Client Client

41 5. The technology 5.7 Telephone connection The interface between the CONCENTO PLUS nurse call system and the telephone equipment is formed by the management interface. A telephone system or the public telephone network (analog) directly can be connected to the analog a/b interface of the management interface. The text messages are sent via the ESPA protocol (ESPA interface on the management interface). Communication with the Telecare Control Centres PNC or WILMA is organized via the CPC protocol. Each management interface provides a speech channel for telephoning. When planning the telephone connection, consideration must therefore be given as to how many speech channels are required Ward speech When a high number of calls is expected, i.e. when frequent phone calls must be made, a management interface is installed for each ward bus for the purpose of connection to the telephone network or telephone system. Ward bus Group electronic Management Interface analog a/b Group bus Group electronic Management Interface analog a/b Ward bus LAN LAN for remote maintenance Management Interface Fig. 15: Ward speech example 39

42 5. The technology Group speech When a smaller number of calls is expected, i.e. when rarely phone calls must be made, the management interface on the group bus takes over connection to the telephone network or telephone system centrally. Ward bus Group electronic Group bus Group electronic Ward bus analog a/b PSTN LAN LAN for remote maintenance Management Interface Telecare Control Centre Fig. 16: Group speech example 40

43 6. ConLog PLUS Management Software The purpose of the ConLog PLUS management software is the central configuration and programming of CONCENTO PLUS nurse call systems, and the logging and evaluation of all system events of these nurse call systems. Fig. 17: ConLog PLUS management software 6.1 System configuration and programming Central configuration of the entire nurse call system Establishment of the logical structure of the nurse call system in wards and shifts / timezones Entry of ward and room names Programming of the management interface, the group electronics and terminals with the project-specific settings via the bus system via the management interface Firmware updates of the management interface, the group electronics and terminals Management of the system interfaces for paging and telephoning Management of connections to Telecare Control Centres Call logging and reporting Logging of all events of the nurse call system, showing the date and time Recording call initiation, call type, call location, call answering, call cancellation Distinguishing between remote cancellation and on-location cancellation Active alarm stack, status messages, event display 41

44 6. ConLog PLUS Management Software SQL database format Simple and effective reporting Reports can be configured according to the parameters, e.g. according to call type, date, room number, floor System requirements Operating system: Microsoft Windows 7 (32 Bit, 64 Bit), Microsoft Windows XP mit SP3, Microsoft Windows Vista CPU with 1 GHz 1 GB RAM 40 GB hard drive 1 serial COM interface DVD drive 17 inch monitor USB 2.0 LAN 42

45 7. System safety 7.1 Reaction of the nurse call system to failures Partial failure of the system If individual group electronics fail, the remaining group electronics continue working. The room functions are maintained even if the controlling group electronics fail. A raised call continues to be displayed on the room lamp and as a reassurance light in the room. All elements that raise calls and their transmission paths are monitored. Failures of or impairments to call transmission are immediately displayed to the nursing staff via the display units still in operation Failure of connected systems In most applications, the CONCENTO PLUS nurse call system is connected to other systems. Nevertheless, it remains an independent system. This means that if telephone systems, computer networks or other interfaces fail, the nurse call system still functions autarkically Power supply failure In the event of a power failure, existing calls and status information are saved and are not lost. Normally, the nurse call system is connected to a back-up power supply. This maintains operation in the event of a power failure. A power supply mains failure message can be displayed in the nurse call system via an input of the group electronic. In buildings without a back-up power supply, operation of the CONCENTO PLUS nurse call system must be maintained by other means. For example, a special power supply unit ( ) is available for this. It provides uninterrupted operation with at least 15 minutes back-up supply from integrated batteries. Separate uninterrupted power supplies are required for the PC with ConLog PLUS Management Software and all other equipment not connected to the system's 24 V supply. These must be provided by the customer, or can be ordered as separate accessories. 43

46 7. System safety 7.2 Nurse call system fault displays Fault displays on equipment for the nursing staff Faults and the fault type are shown on the display of the following equipment: On corridor displays, when there are no calls and presences. On the terminal SD6 P (when presence is activated) when scrolling through the current messages or directly when there are no calls and presences. On the display module (when presence is activated), alternately with calls and presences. Here, the faults are displayed in the same way as calls, i.e. initially only in their own ward or, in the case of group couplings, in the coupled wards. If the fault is not remedied within the call overflow time, it is displayed in all wards in the building ConLog PLUS Management Software All of the nurse call system's fault messages can be identified in the ConLog PLUS management software by looking at the call documentation Fault messages on equipment for technicians Group electronic LED display for group bus faults LED display for faults on own ward bus Fault signal relay (potential-free) switches when the group electronic fails. Also fault signal LED in button 2. Output to fault signal lamp switches when there is a fault on own ward bus. Input for fault signal contact of the power supply unit (24 V DC) leads to mains failure message in the nurse call system Management Interface Fault signal relay (potential-free) for monitoring the Conlog service. Forwarding fault messages to particular destinations (DECT, Pager, PNC/ WILMA) 44

47 8. Room types Frequently used room types are explained in the following pages on the basis of equipment examples. 8.1 Cables legend The following letters are used for cables in the room type plans: Code Cable type Area of use a IY(ST)Y 2x2x0,8 - Secondary lines (except switches with 2 buttons, e.g. Call & Cancel switch/wc) - Ward bus without speech (minimum requirement) - Group bus without speech (minimum requirement) c IY(ST)Y 4x2x0,8 - Ward bus with or without speech - Group bus with or without speech - Secondary lines to switches with 2 buttons, e.g. Call/cancel switch/wc k NYM 2x2,5 mm 2 or NYM 2x1,5 mm 2 or equivalent Power supply, equipotential bonding 45

48 8. Room types 8.2 Patient / resident room Patient / resident room with speech Ward bus Ward bus c+k c+k c+k a a a a x a a

49 8. Room types Per room Terminal SD6 P or Terminal S4 P Pull cord kit for terminal (optional) Room lamp universal, 3 sections or Room lamp universal, 3 sections, with doorplate or Room lamp universal, 3 sections, glass decor Per bed Call switch with 2 connection sockets or Call switch with connection socket Pear push switch with call and light switch, 3 m or Pear push switch with call switch, 3 m or Pear push switch with call and light switch, 3 m or Pear push switch with 2 call switches, 3 m Self-releasing adapter for pear push switch (optional) Extension cable for pear push switch (optional) In WC room Cancel switch/wc or Call & Cancel switch/wc It must be possible to reach a call device from the wash basin, WC, shower and bath tub. Selection: Call switch Pull cord switch (x in order no. stands for frame: J = Jung AS 500, G = Gira Standard 55 matt, GG = Gira Standard 55 glossy, M = Merten M-SMART, B = Berker S.1) Pneumatic switch (x in order no. stands for frame: J = Jung AS 500, G = Gira Standard 55 matt, GG = Gira Standard 55 glossy, M = Merten M-SMART, B = Berker S.1) x x In the seat corner (optional) Call device, e.g. call switch or Call switch with connection socket For accessories required, see accessories table, Page 65. For cable legend, see Page

50 8. Room types Patient / resident room without speech Ward bus Ward bus c+k c+k c+k a x a c Attention! A cable IY(ST)Y 4x2x0.8 is required for connecting the call & cancel switch/wc a a

51 8. Room types Per room Display module or Call/presence combination bus (RAB) Room lamp universal, 3 sections or Room lamp universal, 3 sections, with doorplate or Room lamp universal, 3 sections, glass decor Per bed Call switch with 2 connection sockets or Call switch with connection socket Pear push switch with call and light switch, 3 m or Pear push switch with call switch, 3 m or Pear push switch with call and light switch, 3 m or Pear push switch with 2 call switches, 3 m Self-releasing adapter for pear push switch (optional) Extension cable for pear push switch (optional) In WC room Cancel switch/wc or Call & Cancel switch/wc It must be possible to reach a call device from the wash basin, WC, shower and bath tub. Selection: Call switch Pull cord switch (x in order no. stands for frame: J = Jung AS 500, G = Gira Standard 55 matt, GG = Gira Standard 55 glossy, M = Merten M-SMART, B = Berker S.1) Pneumatic switch (x in order no. stands for frame: J = Jung AS 500, G = Gira Standard 55 matt, GG = Gira Standard 55 glossy, M = Merten M-SMART, B = Berker S.1) x x In the seat corner (optional) Call device, e.g. call switch or Call switch with connection socket For accessories required, see accessories table, Page 65. For cable legend, see Page

52 8. Room types Patient / resident room: Light switching c+k Ward bus Ward bus c+k or or The duration of the generated control signal corresponds to the time for which the light switch is pressed on the pear push switch. Suitable relays Pulse relay (electronic): ELTAKO, ES60-TX60-24VDC ELTAKO, ES VDC SCHIELE entrelec TX60-24V BIAIG electronics TX60-24V Pulse relay (mechanical) *): ELTAKO, 1S9-24 VDC ELTAKO, S VDC Switching relay (mechanical) *): ELTAKO, R VDC (for DIN rail) ELTAKO, R VDC (flush-mounted / surface-mounted version) FINDER, *) Attention! When a mechanical relay is used, it is also necessary to use an anti-surge diode, min. 1N

53 8. Room types 8.3 Staff room c+k Ward bus Ward bus c+k a Per room Terminal SD6 P Room lamp universal, 3 sections or Room lamp universal, 3 sections, with doorplate or Room lamp universal, 3 sections, glass decor For accessories required, see accessories table, Page 65. For cable legend, see Page

54 8. Room types 8.4 Function room Function room with speech c+k Ward bus Ward bus c+k a Per room Terminal SD6 P or Terminal S4 P Pull cord kit for terminal (optional) Room lamp universal, 3 sections or Room lamp universal, 3 sections, with doorplate or Room lamp universal, 3 sections, glass decor If required Call switch with connection socket For accessories required, see accessories table, Page 65. For cable legend, see Page

55 8. Room types Function room without speech c+k Ward bus Ward bus c+k a Per room Display module or Call/presence combination bus (RAB) Room lamp universal, 3 sections or Room lamp universal, 3 sections, with doorplate or Room lamp universal, 3 sections, glass decor If required Call switch with connection socket For accessories required, see accessories table, Page 65. For cable legend, see Page

56 8. Room types 8.5 Ward bathroom Ward bathroom with speech c+k Ward bus Ward bus c+k a a a x x a a Per room Terminal SD6 P or Terminal S4 P Pull cord kit for terminal (optional) Room lamp universal, 3 sections or Room lamp universal, 3 sections, with doorplate or Room lamp universal, 3 sections, glass decor Per location bathroom/wc Call switch, suitable for washbasins Pull cord switch, suitable for shower, WC (x in order no. stands for frame: J = Jung AS 500, G = Gira Standard 55 matt, GG = Gira Standard 55 glossy, M = Merten M-SMART, B = Berker S.1) Pneumatic switch, suitable for bath tub (x in order no. stands for frame: J = Jung AS 500, G = Gira Standard 55 matt, GG = Gira Standard 55 glossy, M = Merten M-SMART, B = Berker S.1) x x For accessories required, see accessories table, Page 65. For cable legend, see Page

57 8. Room types Ward bathroom without speech c+k Ward bus Ward bus c+k a a a x x a a Per room Display module or Call/presence combination bus (RAB) Room lamp universal, 3 sections or Room lamp universal, 3 sections, with doorplate or Room lamp universal, 3 sections, glass decor Per location bathroom/wc Call switch, suitable for washbasins Pull cord switch, suitable for shower, WC (x in order no. stands for frame: J = Jung AS 500, G = Gira Standard 55 matt, GG = Gira Standard 55 glossy, M = Merten M-SMART, B = Berker S.1) Pneumatic switch, suitable for bath tub (x in order no. stands for frame: J = Jung AS 500, G = Gira Standard 55 matt, GG = Gira Standard 55 glossy, M = Merten M-SMART, B = Berker S.1) x x For accessories required, see accessories table, Page 65. For cable legend, see Page

58 8. Room types 8.6 WC with multiple cubicles c+k Ward bus Ward bus c+k a a a a a a a a x x x 56

59 8. Room types Per room Display module or Call/presence combination bus (RAB) or Terminal SD6 P or Terminal S4 P Pull cord kit for terminal (optional) Room lamp universal, 3 sections or Room lamp universal, 3 sections, with doorplate or Room lamp universal, 3 sections, glass decor Per WC cubicle Cancel switch/wc or Call & Cancel switch/wc t must be possible to reach a call device from the wash basin, WC, shower and bath tub. Selection: Call switch Pull cord switch (x in order no. stands for frame: J = Jung AS 500, G = Gira Standard 55 matt, GG = Gira Standard 55 glossy, M = Merten M-SMART, B = Berker S.1) Pneumatic switch (x in order no. stands for frame: J = Jung AS 500, G = Gira Standard 55 matt, GG = Gira Standard 55 glossy, M = Merten M-SMART, B = Berker S.1) x x For accessories required, see accessories table, Page 65. For cable legend, see Page

60 8. Room types 8.7 Lounge / dining room Lounge with speech c+k Ward bus Ward bus c+k a a a a a

61 8. Room types Per room Terminal SD6 P or Terminal S4 P Pull cord kit for terminal (optional) Room lamp universal, 3 sections or Room lamp universal, 3 sections, with doorplate or Room lamp universal, 3 sections, glass decor Per location, calls raised using pear push switch Call switch with 2 connection sockets or Call switch with connection socket Pear push switch with call switch, 3 m or Pear push switch with 2 call switches, 3 m Self-releasing adapter for pear push switch (optional) Extension cable for pear push switch (optional) Per location, calls raised only via call button Call switch For accessories required, see accessories table, Page 65. For cable legend, see Page

62 8. Room types Lounge without speech c+k Ward bus Ward bus c+k a a a a a

63 8. Room types Per room Display module or Call/presence combination bus (RAB) Room lamp universal, 3 sections or Room lamp universal, 3 sections, with doorplate or Room lamp universal, 3 sections, glass decor Per location, calls raised using pear push switch Call switch with 2 connection sockets or Call switch with connection socket Pear push switch with call switch, 3 m or Pear push switch with 2 call switches, 3 m Self-releasing adapter for pear push switch (optional) Extension cable for pear push switch (optional) Per location, calls raised only via call button Call switch For accessories required, see accessories table, Page 65. For cable legend, see Page

64 8. Room types 8.8 Apartment in assisted living c+k Ward bus Ward bus c+k a a a Z Z x

65 8. Room types Per apartment Terminal S4 B Pull cord kit for terminal (optional) Per bed Call switch with 2 connection sockets or Call switch with connection socket Pear push switch with call switch, 3 m or Pear push switch with 2 call switches, 3 m Self-releasing adapter for pear push switch (optional) Extension cable for pear push switch (optional) In bathroom / WC Pull cord switch (x in order no. stands for frame: J = Jung AS 500, G = Gira Standard 55 matt, GG = Gira Standard 55 glossy, M = Merten M-SMART, B = Berker S.1) x If required Call switch, e.g. in the kitchen For raising calls in the entire living environment: Radio receiver MHz (for connecting to call switch with connection socket or call switch with 2 connection sockets) with handheld transmitter (per resident) Z Z For accessories required, see accessories table, Page 65. For cable legend, see Page

66 8. Room types 64

67 9. Accessories required Accessories must be ordered for various devices! Refer to the table below for the accessories required, such as central plates, frames, mounting kits and back boxes. Product name Product Order No. Central plate Order No. Select frame 1) Mounting kit Order No gang 2) Call switch with connection socket Call switch with 2 connection sockets Pull cord switch incl. frame Berker S B Pull cord switch incl. frame Gira Standard 55 matt G Pull switch incl. frame Gira Standard 55, glossy GG Pull cord switch, incl. frame Jung AS J Pull cord switch incl. frame Merten M-SMART M Pneumatic switch incl. frame Berker S B Pneumatic switch incl. frame Gira Standard 55, G matt Pneumatic switch incl. frame Gira Standard 55, GG glossy Pneumatic switch, incl. frame Jung AS J Pneumatic switch incl. frame Merten M-SMART M Call switch Call & Cancel switch/wc Cancel switch/wc Back box 2-gang 3) Legend: 1) Select frame: Jung AS 500: , Berker S.1: , Gira Standard 55 matt: , Gira Standard 55 glossy: , Merten System M-SMART: ) Back box, 1-gang: Solid wall: , partition wall: ) Back box, 2-gang: Solid wall: , partition wall:

68 9. Accessories required Mounting Back box Product name Product Order No. Central plate Order No. Select frame 1) kit Order No gang 2) 2-gang 3) Room lamp universal, 3 sections Connector, 7-pole Order No Room lamp universal, 3 sections, with doorplate Connector, 7-pole Order No Room lamp universal, 3 sections, glass decor Connector, 7-pole Order No Group electronic (GE) Terminal SD6 P Terminal S4 P Terminal S4 B Display module RAB Legend: 1) Select frame: Jung AS 500: , Berker S.1: , Gira Standard 55 matt: , Gira Standard 55 glossy: , Merten System M-SMART: ) Back box, 1-gang: Solid wall: , partition wall: ) Back box, 2-gang: Solid wall: , partition wall:

69 10. Product overview This chapter contains an overview of all products of the CONCENTO PLUS system, organised according to the following product groups: Room terminals Room lamps, corridor displays Switches Call switches with connection socket Plug-in call devices for connecting to connection socket Wireless call devices Wired call devices Software and PC System controller Power supply units Frames and back boxes 67

70 10. Product overview 10.1 Room terminals Terminals Functions Terminal SD6 P Room terminal incorporating duplex speech system, with display and buttons for registration of presence, raising calls, call answering and universal button. The room terminal controls and monitors all room functions. It is directly connected to the ward bus. All room devices (room lamp and switches) are connected to the room terminal. Red call button with reassurance light and integrated location light Green presence button 1 with reminder light Yellow presence button 2 with reminder light Grey answer button for answering forwarded calls, with reminder light Grey remote cancel button for cancelling calls that can be remotely cancelled after speech connection, with reminder light Grey universal button, freely programmable, preferably used as WC call & cancel switch with reminder light 2-line illuminated display, 8-digit. Context-dependent display, e.g. for visual indication of forwarded calls: Call type, group and room number or 25-digit alias text, number of further calls in the background, time and system messages Audible indication of forwarded calls Operating mode adjustable via display menu: - Resident / patient room - Staff room (incl. announcement function) - Staff room with function as main console (incl. manual timezone change) Free function assignment of the 7 inputs Max. 4 monitored room devices can be connected per input 3 outputs for connecting a room lamp Pull cord available as an accessory ( ) Connection to the ward bus in conjunction with mounting kit for terminal or GE, Order no Dimensions (HxWxD): 190 x 102 x 50 mm 68

71 10. Product overview Functions Terminal S4 P Room terminal incorporating duplex speech system, with buttons for registration of presence, raising calls and call answering. The room terminal controls and monitors all room functions. It is directly connected to the ward bus. All room devices (room lamp and switches) are connected to the room terminal. Red call button with reassurance light and integrated location light Green presence button 1 with reminder light Grey answer button for answering forwarded calls, with reminder light Grey remote cancel button for cancelling calls that can be remotely cancelled after speech connection, with reminder light Audible indication of forwarded calls Free function assignment of the 7 inputs via external module Max. 4 monitored room devices can be connected per input 3 outputs for connecting a room lamp Pull cord available as an accessory ( ) Connection to the ward bus in conjunction with mounting kit for terminal or GE, Order no Dimensions (HxWxD): 190 x 102 x 50 mm 69

72 10. Product overview Functions Terminal S4 B Room terminal incorporating duplex speech system, with buttons for staff registration of presence, raising calls, residents' registration of presence and absence, as well as answering calls. The room terminal controls and monitors all room functions. It is directly connected to the ward bus. All room devices (room lamp and switches) are connected to the room terminal. Red call button with reassurance light and integrated location light Green presence button 1 with reminder light Grey day button for inactivity alarm function. Additional function as an answer button for answering forwarded calls, with reminder light Grey away button for inactivity alarm function, with reminder light. Additional function as a remote cancel button for cancelling calls that can be remotely cancelled after speech connection Audible indication of forwarded calls Free function assignment of the 7 inputs via external module Max. 4 monitored room devices can be connected per input 3 outputs for connecting a room lamp Pull cord available as an accessory ( ) Connection to the ward bus in conjunction with mounting kit for terminal or GE, Order no Dimensions (HxWxD): 190 x 102 x 50 mm 70

73 10. Product overview Functions Mounting kit for terminal or GE Wall bracket and connectors for securing and wiring up a terminal or a group electronic (GE). Screw attachment Plug-in screw connector, 4-pole, as connector for voltage supply, max. wire cross section 2.5 mm 2 Plug-in screw connector, 10-pole, as connector, with reverse polarity protection Plug-in screw connector, 12-pole, as connector, with reverse polarity protection Order no Dimensions (HxWxD): 172 x 79 x 16 mm Surface mounting frame for mounting kit For surface-mounting a terminal or a group electronic (GE) in conjunction with the mounting kit, Mounting plate in white Resopalit with rounded ABS safety edges Dimensions (HxWxD): 172 x 79 x 19 mm Pull cord kit for terminal As an optional accessory for the terminals Red pull cord, length 1.5 m Triangular handle, red 14 cm connecting cable, 2-pole with plug, to be connected at input R7 of the terminal For installation in the mounting kit,

74 10. Product overview Display module, RAB Functions Display module Room terminal without speech, with display and buttons for registration of presence and raising calls. The room terminal controls and monitors all room functions. It is directly connected to the ward bus. All room devices (room lamp and switches) are connected to the room terminal. Red call button with reassurance light and integrated location light Green presence button 1 with reminder light 2-line illuminated display, 8-digit. Context-dependent display, e.g. for visual indication of forwarded calls: Call type, group and room number or up to 25-digit alias text, number of further calls in the background, time and system messages Audible indication of forwarded calls Input for WC call switch (NO contact) Input for WC cancel switch (NO contact) 3 inputs for beds (NO contact), can be changed via display menu to: NO contact / NC contact, call type from more than 30 variants Max. 4 monitored room devices can be connected per input 3 outputs for connecting a room lamp Connection to the ward bus Order no Dimensions (HxWxD): 102 x 100 x 29 mm 72

75 10. Product overview Functions Call/presence combination bus (RAB) Room terminal without speech, with buttons for registration of presence and raising calls. The room terminal controls and monitors all room functions. It is directly connected to the ward bus. All room devices (room lamp and switches) are connected to the room terminal. Red call button with reassurance light and integrated location light Green presence button 1 with reminder light Audible indication of forwarded calls Input for WC call switch (NO contact) Input for WC cancel switch (NO contact) 3 inputs for beds (NO contact), can be changed via display menu to: NO contact / NC contact, call type from more than 30 variants Max. 4 monitored room devices can be connected per input 3 outputs for connecting a room lamp Connection to the ward bus Order no Order central plate and frame separately. See accessories table on Page 65. See Page 99 for a description of the frames. Central plate for 2 buttons Central plate for call/presence combination bus (RAB) or for call & cancel switch/wc. Material: ABS Colour: alpine white, similar to RAL 9010 External dimensions: 55 x 55 mm

76 10. Product overview 10.2 Room lamps, corridor displays Room lamps Functions Room lamp universal, 3 sections Signal lamp with 3 light sections for visual indication of all call types, staff presence and WC call/ Emergency call WC as individual display. Red LED: Calls Green LED: Presence White LED: WC call, Emergency call WC Frame: ABS Wall mounting Connection to the room terminal Order no Dimensions (HxWxD): 110 x 150 x 40 mm Room lamp universal, 3 sections, with doorplate Same as , but with doorplate as labelling area for the room name Dimensions (HxWxD): 190 x 150 x 40 mm Labelling area (HxW): approx. 70 x 92 mm Room lamp universal, 3 sections, glass decor Same as , but with decorative glass frame Dimensions (HxWxD): 110 x 150 x 40 mm 74

77 10. Product overview Functions Doorplate universal Doorplate without light sections, for universal use. Suitable for installation on walls, in corridors or in rooms. Modular design. Order no Dimensions (HxWxD): 190 x 150 x 40 mm Labelling area (HxW): approx. 70 x 92 mm Connector, 7-pole Plug-in screw terminal, e.g. for connecting the room lamps universal Dimensions (HxWxD): 10 x 28 x 15 mm 75

78 10. Product overview Corridor displays Functions Corridor display, 8-digit Display for the alphanumeric displaying of calls and general system information. Wall mounting. 8-digit text display, text height 50 mm Light colour: Red Keyholes for wall mounting Connecting cable: approx. 1.2 m Connection to the ward bus Order no Dimensions (HxWxD): 110 x 150 x 40 mm Corridor display, 8-digit, double-sided Same as , but double-sided version, ceiling suspension. Incl. ceiling suspension, 30 cm long Corridor display, 16-digit Display for the alphanumeric displaying of calls and general system information. Wall mounting. 16-digit text display, text height 50 mm Light colour: Red Keyholes for wall mounting Connecting cable: approx. 1.2 m Connection to the ward bus Dimensions (HxWxD): 125 x 804 x 43 mm Corridor display, 16-digit, double-sided Same as , but double-sided version, ceiling suspension. Incl. ceiling suspension, 30 cm long

79 10. Product overview 10.3 Switches Call switches, cancel switches Functions Call switch Red call button with reassurance light and integrated location light Wall mounting Connection to the room terminal Order no Order central plate and frame separately. See accessories table on Page 65. See Page 99 for a description of the frames. Call & Cancel switch/wc Red call button with reassurance light and integrated location light Grey WC cancel button with reminder light for cancelling WC calls and Emergency calls WC Wall mounting Connection to the room terminal Order central plate and frame separately. See accessories table on Page 65. See Page 99 for a description of the frames. Cancel switch/wc Grey WC cancel switch with reminder light for cancelling WC calls and Emergency calls WC Wall mounting Connection to the room terminal Order central plate and frame separately. See accessories table on Page 65. See Page 99 for a description of the frames. 77

80 10. Product overview Functions Central plate for 2 buttons Central plate for call/presence combination bus or for call & cancel switch/wc. Material: ABS Colour: alpine white, similar to RAL 9010 External dimensions: 55 x 55 mm Order no Central plate for 1 button Central plate for call switch or cancel switch/wc. Material: ABS Colour: alpine white, similar to RAL 9010 External dimensions: 55 x 55 mm

81 Pull cord or pneumatic switches Functions Order no. Pull cord switch 2 m red cord with red triangular handle for raising a call by pulling the cord Reassurance light Ceiling or wall mounting Connection to the room terminal Central plate 55 x 55 included incl. frame Jung AS 500 incl. frame Berker S. 1 incl. frame Gira Standard 55 matt incl. frame Gira Standard 55 glossy incl. frame Merten System M-SMART J B G GG M Pneumatic switch 2 m air hose with red rubber ball Reassurance light Hose is monitored for pulling off. Ceiling or wall mounting Connection to the room terminal Central plate 55 x 55 included incl. frame Jung AS 500 incl. frame Berker S. 1 incl. frame Gira Standard 55 matt incl. frame Gira Standard 55 glossy incl. frame Merten System M-SMART J B G GG M 79

82 10.4 Call switches with connection socket Functions Call switch with connection socket Red call button with reassurance light and integrated location light Connection socket for pear push switch or another plug-in call device Unplugging monitoring Wall mounting Connection to the room terminal Order no Order central plate and frame separately. See accessories table on Page 65. See Page 99 for a description of the frames. Call switch with 2 connection sockets Same as , but with two connection sockets for pear push switches or other plug-in call devices Order central plate and frame separately. See accessories table on Page 65. See Page 99 for a description of the frames. Central plate for 1 button & 1 connection socket Central plate for call switch with connection socket. Material: ABS Colour: alpine white, similar to RAL 9010 External dimensions: 55 x 55 mm Central plate for 1 button & 2 connection sockets Central plate for call switch with 2 connection sockets. Material: ABS Colour: alpine white, similar to RAL 9010 External dimensions: 55 x 55 mm

83 10.5 Plug-in call devices for connecting to connection socket Pear push switches Functions Pear push switch incl. call switch, 3 m Water protected call switch for raising calls. Red call button with reassurance light and integrated location light 3 tactile locating points on the call button Protected against temporary immersion in water and dust-tight (IP67) 3 m flexible connecting cable with plug Plug-in connector on call switch with connection socket, x0 Order no Dimensions (HxWxD): 70 x 35 x 10 mm Pear push switch incl. call and light switch Same as , but also incl. yellow light switch for switching the reading or room light Pear push switch incl. 2 call switches, 3 m Moisture-protected call switch for raising calls. 2 red call buttons with reassurance light and integrated location light 3 m flexible connecting cable with plug Plug-in connector on call switch with connection socket, x Dimensions (HxWxD): 60 x 29 mm Pear push switch incl. call and light switch Same as , but incl. only one call button and also incl. a yellow light switch for switching the reading or room light

84 Functions Self-releasing adapter for pear push switch Device protection for connecting pear push switches, xx. Length: 20 cm Order no Extension cable for pear push switch, 5 m for pear push switch, xx Equipment and cable clamp Pragmatic protection made of ABS plastic for all equipment operated by patients. Exact routing of all cables along the bed rail or the bed gallows. No more damage due to the patient's attempt to pull themselves up on expensive equipment: The equipment and cable clamp detaches itself automatically from the rail in the event of pulling. Various attachment possibilities for different cable diameters For using hoses or cables with a diameter of 4, 5, 6 and 9 mm (e.g. pear push switch) The symmetrical design allows 2 equipment and cable clamps to be put together mirror-inverted in order to double the holding strength Dimensions: max. height: 160 mm max. thickness: 18 mm Width: 70 mm 82

85 Plug-in call devices for special applications Functions Diagnostic connection cable For plug-connecting an electrical medical device to a call switch with connection socket, x0. Length: 3 m 8-pole mini-din plug Strain relief Loose wire ends Order no Large-surface pneumatic switch Call switch with a large-surface pneumatic call button. Only a very slight actuation force is required in order to raise the call. It is therefore very well suited when there are activation problems due to illness. Red call button LED call indicator Console housing, also permanently installable Protected against splash water on all sides (IP44) 3 m flexible connecting cable with plug Plug-in connection to call switch with connection socket, x0 Z Dimensions (HxØ): 45 x 110 mm Button diameter: 90 mm Sound detector Highly sensitive sound detector in desktop housing. Integrated On/Off button Raising a call manually Variable sensitivity and response Operating, initiation and reassurance lamp Console housing, also permanently installable 3 m flexible connecting cable with plug Plug-in connection to call switch with connection socket, x0 Z Dimensions (HxØ): 50 x 110 mm 83

86 Functions 1-channel respiratory dual sensor system Flexible aid for raising a call via respiration. Highly-sensitive sensor detects the slightest respiratory movements on the mouthpiece and raises a call in the nurse call system. Thanks to easily interchangeable disposable parts such as the mouthpiece, antibacterial filter and hose, the system is well suited for frequent patient turnover. Simple disassembly of contaminated parts is performed without a tool and can be done by nursing staff. The stable supporting arm with universal claw can be used almost everywhere without a tool: on round and square profiles (bed rails or stands) up to 6 cm thick. 1-channel sensor unit for raising calls by sucking or blowing Universal articulated arm, stainless steel with fastening clamp. Disposable set for patients Degree of protection: IP44 3 m flexible connecting cable with plug Plug-in connection to call switch with connection socket, x0 Order no. Z Dimensions (HxWxD): 180 x 105 x 65 mm Weight: approx g Sensor mat CONCENTO Large-surface mat for raising a call by stepping on or pressing the mat. The mat is positioned e.g. by the bed. A call is raised when the resident/patient gets out of bed or falls out of bed and onto the mat. Large sensor surface area Watertight 3 m flexible connecting cable with plug Plug-in connector on call switch with connection socket, x0 Z Dimensions (WxD): 1200 x 500 mm Stepping surface thickness: 4mm Colour: Ivory-coloured 84

87 10.6 Wireless call devices Functions Radio receiver MHz Switching receiver on operating frequency MHz (social alarm frequency) for receiving the signals from assigned transmitters. Note: The radio transmission is not monitored and the unit comprised of the radio transmitter and radio receiver may only be used as an additional call device in conjunction with a nurse call system. Integrated antenna 8 radio transmitters assignable Master mode can be activated to receive any desired number of radio transmitters Intelligent battery monitoring of the assigned transmitters (if present at the transmitter end) Monitoring of the transmitter's automatic daily message in accordance with EN Operation monitoring in accordance with EN Protection Class: IP20 Range dependent on the spatial conditions, approx. 15 to 30 m Short connecting cable with plug Plug-in connection to call switch with connection socket, x0 Dimensions (HxWxD): 130 x 40 x 24 mm Weight: approx. 70 g Magnetic wall bracket Bracket for magnetically securing a radio receiver on the wall next to the call switch with connection socket. Dimensions (HxWxD): 60 x 25 x 10 mm Handheld transmitter Watch-shaped handheld transmitter with stretch armband for carrying on the wrist. Red call button, rubber-coated, Ø: 19 mm LED call indicator Protected against powerful water jets (IP66) Automatic daily message in accordance with EN Battery monitoring with control message to receiver Typical battery life: 3 years 3.0 V button cell battery CR2032, replaceable Radio frequency: MHz Stretch armband with clip fastener Receiver required for the radio signals: Radio receiver MHz, Z Order no. Z Z Z Dimensions (HxWxD): 46 x 43 x 15 mm Weight: approx. 25 g 85

88 Functions Radio call switch Radio transmitter for direct wall mounting. Red call button, rubber-coated, Ø: 19 mm LED call indicator Protected against powerful water jets (IP66) Automatic daily message in accordance with EN Battery monitoring with control message to receiver Typical battery life: 3 years 3.0 V button cell battery CR2032, replaceable Radio frequency: MHz Wall mounting via screw assembly or doublesided adhesive tape Receiver required for the radio signals: Radio receiver MHz, Z Order no. Z Dimensions (ØxT): 80 x 15 mm Weight: approx. 55 g Large-surface radio pneumatic switch Same as Z , see Page 83, but wireless. Automatic daily message in accordance with EN Battery monitoring with control message to receiver Typical battery life: 3 years 3.0 V button cell battery CR2032, replaceable Radio frequency: MHz Receiver required for the radio signals: Radio receiver MHz, Z Z Dimensions (HxØ): 45 x 110 mm Button diameter: 90 mm 86

89 10.7 Wired call devices Functions Sensor mat with free cable ends Same as Z , see Page 84, but with exposed wire ends for connecting to the alarm system of your choice. NO contact Order no. Z Dimensions (WxD): 1200 x 500 mm Stepping surface thickness: 4 mm Smoke detector 24 V DC Configured as optoelectronic smoke detector for the early detection of smoke. Measuring principle: via IRED radiation / lens (scatter) / photo diode Response threshold in acc. with pren ISO Sensor interruption signal Beep + after approx. 22 s LED pulse Individual display: LED red Audible alarm approx. 85 db (3 m) Approval VdS G Monitoring surface area 60 m 2 Ceiling installation, max. 6 m height Relay module with potential-free contact for forwarding the alarm Power supply circuit board 24 V DC Dimensions (HxD): 48 x 96 mm Telephone interface relay For connecting analog telephones to a nurse call system, for forwarding calls as a telephone call. Call voltage: V AC Power supply: 5-40 V On/Off switch Switch output: Changeover contact Adjustable call pause bridging Adjustable switching time of the output contact Dimensions (HxWxD): 70 x 35 x 70 mm Mounting on 35 mm DIN rail 87

90 10.8 Software and PC ConLog PLUS Management Software Functions ConLog PLUS Management Software The purpose of the ConLog PLUS management software is the central configuration and programming of the nurse call system, and the logging and evaluation of all system events For details, see Chapter 6, Page 41 onwards. Connecting the PC to the management interface and LAN. Order separately: Serial extension cable Personal Computer Order no ConLog PLUS Management Software Client Up to 10 client workstations, , can be operated in the network with one server workstation, Order separately: Personal Computer Remote maintenance module for ConLog PLUS For remotely controlling the computer on which the ConLog PLUS management software is installed in order to diagnose faults, install updates or provide support during operation. A service technician logs onto the PC to do this. Third-party remote access is not possible. Attention! You require your own ISDN line for the PC

91 PC Functions Personal Computer, English Personal Computer e.g. for ConLog PLUS Management Software. Minimum configuration compatible with industry standard: Processor model: Intel Celeron Dual Core E3400 Main memory: 1 GB DDR3 Hard drive: 250 GB Optical drive: DVD burner Network card: Ethernet 10/100/100 Mbps Keyboard, mouse Operating system: Windows 7 Professional 32-bit, English VGA, DisplayPort, serial connection, Ethernet, several USB 2.0, 3x PCI Serial COM port 17 inch TFT monitor Supply voltage: 230 V AC / 50 Hz The version corresponds with the respective standard equipment available for delivery. Further details on request. Order no DCF77 radio clock module for PC For synchronising the nurse call system with the standard time of the DCF77 transmitter. USB connection for the PC CD with driver software Cable length: 2 m Dimensions (HxWxD): 80 x 40 x 20 mm 89

92 10.9 System control Group electronic Functions Group electronic (GE) The group electronic (GE) is the control unit inside the decentralised system structure of the CONCENTO PLUS system. The GE monitors and controls all of the data traffic, as well as the speech communication of all users on a ward bus. All group electronics are connected to each other via the group bus. The group bus is controlled by all connected group electronics according to the master-slave principle. Control of the ward bus Control of functions covering more than one ward such as group coupling, shift operation, speech connection covering more than one group, higher-order calls Master-slave principle on the group bus Display of the master-slave status Up to 40 users per ward bus Up to 40 users per group bus Up to 128 logical groups per system Fault display for the group electronic Fault display for the group bus Fault display for the ward bus Button for displaying the active messages (calls, presence, faults) on the ward bus 2-line display, 8-digit, with backlighting for status display: Time, shift and number of messages in the system 3 buttons for operating the display menu Output to a group lamp, 24 V / 300 ma Output to the fault lamp, 24 V / 300 ma Output to the fault signal relay (NO/NC), potential-free Input for mains power failure message (24 V DC), preferably in conjunction with power supply unit UPS, , or power supply unit UPS 60, Stand-alone operation possible without group bus Service interface Group electronic can be programmed and configured during operation Wall mounting in floor distributors or installation rooms Connection in conjunction with mounting kit for terminal or GE, Order no Dimensions (HxWxD): 190 x 102 x 50 mm 90

93 Functions Mounting kit for terminal or GE Wall bracket and connectors for securing and wiring up a terminal or a group electronic (GE). Screw attachment Plug-in screw connector, 4-pole, as connector for voltage supply, max. wire cross section 2.5 mm 2 Plug-in screw connector, 10-pole, as connector, with reverse polarity protection Plug-in screw connector, 12-pole, as connector, with reverse polarity protection Order no Dimensions (HxWxD): 172 x 79 x 16 mm Surface mounting frame for mounting kit For surface-mounting of a terminal or a group electronic (GE) in conjunction with the mounting kit, Mounting plate in white Resopalit with rounded ABS safety edges Dimensions (HxWxD): 172 x 79 x 19 mm 91

94 Management Interface Functions Management Interface For transmitting call and system messages, spoken announcements and for the connection of telephone systems. There are additional interfaces for system administration and for forwarding logging data. Convenient programming with ConLog PLUS management software Extensive configuration possibilities of the various interfaces and system parameters Connection to Telecare Control Centre (PNC or WILMA) Intelligent status displays: Data bus, ESPA 4.4.4, telephone connection and ConLog PLUS connection Extensive information display: Date, time, IP address, ID number Wall mounting via 1-gang back box or cable duct SDHC memory card (4 GB) for data saving Real-time clock, lithium battery CR2032, exchangeable Interfaces: RS232, interface to the nurse call server RS232, interface, ESPA protocol RJ45, network connection up to 100 MBit/s RJ45, connection prepared for VoIPand ESPA- X protocol up to 100 MBit/s RJ11, telephone connection USB connection prepared for future applications Fault signal output, potential-free (NO/NC) Connection to group bus or ward bus Order no Dimensions (HxWxD): 135 x 190 x 90 mm Null modem cable For example for connecting the management interface to paging systems, ESPA Sub-D, 9-pole, socket/socket

95 Functions Serial extension cable For example for connecting the ConLog PLUS management software to the management interface. 9-pole Sub-D Length: 3 m Order no Interface converter RS232 to RS485 For converting RS 232 interfaces to RS 422/485 interfaces. Required for extending the interface between the management interface and radio paging system. Maximum cable length: 1,000 m 9 V DC plug-in power supply unit included D-sub adapter cable Required for extending the interface between the management interface and radio paging system using the interface converter, pole Sub-D socket 25-pole Sub-D plug Length: 25 cm

96 Fire alarm interface Functions Fire alarm interface For connecting a fire alarm system via ESPA protocol to the nurse call system. Note: This system does not replace a fire alarm system alert in accordance with DIN VDE Standard configuration programmed Programming via the supplied software tool BMA-IConfig Coupling of alarms for display in the nurse call system depending on the system programming: Logical group and room number or alias text Connection on group bus RS232, interface to fire alarm system, preferably FAT Order no Dimensions (HxWxD): 190 x 116 x 63 mm 94

97 10.10 Power supply units Functions Power supply unit UPS Power supply unit for the nurse call system's power supply, with safety extra-low voltage SELV, in accordance with EN The number of rooms that can be connected is project-specific. Uninterrupted operation with at least 15 minutes back-up supply from integrated batteries. Wide range input for international use. With short circuit and overload protection. Control LEDs and contact outputs for forwarding status information. Closed version in Protection Class I Designed for wall mounting. Input: Nominal input voltage: V AC Voltage range: V AC Input frequency: Input current: Hz 4 A at 115 V AC 2 A at 230 V AC Output: Nominal output voltage: 24 V DC +/- 2% - in battery operation: typ V DC Output current: 12 A Output power: 288 W Battery capacity: 7 Ah Charging current: typ. 700 ma Back-up: approx. 17 min at 80% load Connections: Mains input: direct mains connection via internal screw terminal Outputs: pluggable via terminal General: MTBF: 100,000 hours (without batteries) Dimensions (HxWxD): 244 x 325 x 178 mm Weight: 9 kg Order no

98 Functions Power supply unit Power supply unit for the nurse call system's power supply, with safety extra-low voltage SELV, in accordance with EN The number of rooms that can be connected is project-specific Wide range input for international use. With short circuit and overload protection. Control LEDs and contact outputs for forwarding status information. Closed version in Protection Class I Designed for wall mounting. Input: Nominal input voltage: V AC Voltage range: V AC Input frequency: Input current: Hz 4 A at 115 V AC 2 A at 230 V AC Output: Nominal output voltage: 24 V DC +/- 2% Output current: 12 A Output power: 288 W Connections: Mains input: direct mains connection via internal screw terminal Outputs: pluggable via terminal General: MTBF: 100,000 hours Dimensions (HxWxD): 244 x 325 x 178 mm Weight: 2 kg Order no

99 Functions Power supply unit UPS 60 Power supply unit for the nurse call system's power supply, with safety extra-low voltage SELV, in accordance with EN The number of rooms that can be connected is project-specific. Uninterrupted operation in conjunction with the battery set, order no , with approx. 1 hour back-up supply. Wide range input for international use. With short circuit and overload protection. Control LEDs and contact outputs for forwarding status information. Closed version in Protection Class I Intended for wall mounting, preferably above the battery set for UPS 60. Input: Nominal input voltage: V AC Voltage range: V AC Input frequency: Input current: Hz 5,5 A at 115 V AC 3 A at 230 V AC Output: Nominal output voltage: 24 V DC +/- 2% - in battery operation: typ V DC Output current: 12,5 A Output power: 288 W Battery capacity to be connected: 24 Ah Charging current typ. 3,0 A Back-up: approx. 1 h Connections: Mains input: direct mains connection via internal screw terminal Battery connection: Cage clamp connection Outputs: via screw / plug terminal General: MTBF: 100,000 hours Dimensions (HxWxD): 244 x 325 x 178 mm Weight: 4 kg Order no Battery set for UPS 60 for power supply unit UPS 60, order no Closed version in Protection Class III. Intended for wall mounting, preferably below the power supply unit UPS 60 Nominal input voltage: 24 VDC Output current: 12.5 A Output voltage: typ V DC Battery capacity: 24 Ah Connection to power supply unit: Cage clamp Dimensions (HxWxD): 244 x 450 x 178 mm Weight: 25.2 kg

100 Functions Power supply unit 5A Power supply unit for supplying power to the nurse call system. The number of rooms that can be connected is project-specific. Flush-mounted unit. The connection must be made with fixed wiring. Input: Nominal input voltage: / V AC, 50/60 Hz Order no Input current at 120/230V: 2,2/1,2 A eff Recommended circuit-breaker characteristic C 6 A on 1-phase AC mains. For 2-phase operation on 2 outer conductors of a three-phase mains, a circuit breaker with twopole connection or a motor circuit breaker must be provided as the protective device, using the outer contact pairs. Power consumption (effective power): 140 W Output: DC output voltage: State as delivered: 24 V +/-1% Adjustment range 24 V to 28.8 V (adjustment via potentiometer on the front side of the unit) Output direct current: 0-5 A Weight: 1.2 kg 98

101 10.11 Frames and back boxes Frames Functions Frame Jung AS 500 Frame, 1-gang, 81 x 81 mm Internal dimensions: 55 mm Colour: White Manufacturer's article no.: AS 581 WW Order no Frame Gira Standard 55 matt Frame, 1-gang, 81 x 81 mm Internal dimensions: 55 mm Colour: Pure white, silky matt Manufacturer's article no.: Frame Gira Standard 55 glossy Frame, 1-gang, 81 x 81 mm Internal dimensions: 55 mm Colour: Pure white, glossy Manufacturer's article no.: Frame Merten System M-SMART Frame, 1-gang, 81 x 81 mm Internal dimensions: 55 mm Colour: polar white, classy matt Manufacturer's article no.: Frame Berker S.1 Frame, 1-gang, 81 x 81 mm Internal dimensions: 55 mm Colour: polar white, matt Manufacturer's article no.:

102 Back boxes Functions Back box solid wall, 1-gang Dimensions: Ø 66 mm / D 42 mm Order no Back box solid wall, 2-gang Dimensions (HxWxD): 140 x 69 x 42 mm Back box partition wall, 1-gang Dimensions: Ø 68 mm / T 45 mm Back box partition wall, 2-gang Dimensions (HxWxD): 142 x 68 x 45 mm

103 11. Index 1 1-channel respiratory dual sensor system, 84 A Accessories, 65 Acitve, 9 Alarm call, 7, 9, 13, 14 Alarm calls, 9, 11, 13, 14, 31 Alarm stack, 41 Alias texts, 27, 28, 29, 68, 72 Announcements, 3,19, 68 Answer button, 18, 68, 69, 70 Answerable, 31 Apartment, 62, 63 Assisted living, 62 Audible call indication, 14 Available on call, 21 Away button, 70 B Back box partition wall, 1-gang, 65, 66, 100 Back box partition wall, 2-gang, 65, 66, 100 Back box solid wall, 1-gang, 65, 66, 100 Back box solid wall, 2-gang, 65, 66, 100 Back boxes, 65, 100 Bathroom, 54, 55 Battery set for UPS 60, 97 Bed, 49, 63 Bed call, 9, 17 C Cables, 37, 45 Cables legend, 45 Call & Cancel switch/wc, 4, 16, 45, 47, 48, 49, 57, 65, 77 Call Bed, 9, 13, 14 Call button, 9, 10, 16, 68, 69, 70, 72, 73, 77, 80, 81 Call category, 9, 11 Call delay, 30 Call devices, 16 Call forwarding, 7, 14 Call location, 12, 15, 17, 18, 24, 41 Call logging, 41 Call overflow time, 30 Call retransmission, 30 Call switch, 4, 16, 47, 49, 54, 55, 57, 59, 61, 63, 65, 77 Call switch with 2 connection sockets, 47, 49, 59, 61, 63, 65, 80 Call switch with connection socket, 4, 16, 47, 49, 52, 53, 59, 61, 63, 65, 80, 83, 84 Call tone, 14, 17, 18, 31, 68, 69, 70, 72, 73 Call type, 9, 12, 13, 15, 24, 31, 41, 68 abbreviations, 13 Call with speech possibility, 1724 Call without speech possibility, 17, 24 Call/presence combination bus, 8, 14, 18, 24, 34, 37, 49, 53, 55, 57, 61, 73 Calls, 9, 11, 13, 14, 31, 44 Cancel button, 18 Cancel switch/wc, 47, 49, 57, 65, 77 Cancelling, 7, 17, 18, 23, 24, 69, 77 Cancelling a call, 7, 17, 18, 23, 24, 41, 69 Cancelling remotely, 17, 23, 31, 41 Central plate for 1 button, 78 Central plate for 1 button & 1 connection socket, 80 Central plate for 1 button & 2 connection sockets, 80 Central plate for 2 buttons, 73, 78 Client, 38, 88 ConLog PLUS Management Software, 3, 4, 35, 38, 41, 44, 88 ConLog PLUS Management Software Client, 88 Connection socket, 80 Connector, 7-pole, 66, 75 Corridor display, 4, 12, 15, 27, 29, 37, 44, 76 call types, 13 Corridor display, 16-digit, 12, 29, 76 Corridor display, 16-digit, double-sided, 12, 76 Corridor display, 8-digit, 12, 29, 76 Corridor display, 8-digit, double-sided, 12, 76 CPC protocol, 39 D D-sub adapter cable, 93 Daily message, 70 Day button, 70 DCF77 radio clock module for PC, 89 DECT, 21, 34, 44 Diagnostic call, 9 Diagnostic connection cable, 83 DIN VDE 0834, 3, 4, 27, 31 Disconnection call, 9 Display, 15, 17, 18, 22, 23, 68, 72, 90 Display module, 4, 8, 9, 13, 14, 15, 18, 24, 27, 28, 32, 34, 44, 49, 53, 55, 57, 61, 66, 72 Doctor, 7 Door alarm, 32 Doorplate universal, 75 Double arrow, 17 E Emergency call 1, 9, 13, 14 Emergency call 2, 9, 13,

104 11. Index Emergency call Bed, 9, 13, 14 Emergency call WC, 9, 11, 13, 14, 17, 18, 24, 74, 77 Emergency calls, 7, 9, 11, 13, 14, 31 Equipment and cable clamp, 82 Equipotential bonding, 45 ESPA 4.4.4, 34, 39, 92 Example ward, 4 Extending the speech duration, 23 Extension cable for pear push switch, 47, 49, 59, 61, 63, 82 F Failure, 43 Fault display, 44, 90 Fault signal relay, 44, 90 Fire alarm, 9 Fire alarm interface, 94 Firmware update, 41 Flexibility, 27 Frame Berker S.1, 65, 66, 99 Frame Gira Standard 55 glossy, 65, 66, 99 Frame Gira Standard 55 matt, 65, 66, 99 Frame Jung AS 500, 65, 66, 99 Frame Merten System M-SMART, 65, 66, 99 Frames, 65, 99 Fresh call time period, 30 Function room, 53 with speech, 52 without speech, 53 Functions, 7 G GE, 90 Green, 7, 11, 68, 69, 70, 72, 73, 74 Grey, 17, 68, 69, 70, 77 Group bus, 34, 37, 38, 39, 40, 44, 45, 90, 92, 94 Group coupling, 3, 20, 90 Group electronic, 4, 34, 41, 43, 66 71, 90 Group speech, 40 H Handheld transmitter, 63, 85 Handling a call on the telephone, 23 Handling a call with speech, 17 Handling a call without speech, 18 Telecare Control Centre, 3 I Inactivity alarm, 9, 17, 70 Initiating a call, 16 Inputs, 32, 68, 69, 70 Interface converter RS232 to RS485, 93 ISDN, 88 L Large-surface pneumatic switch, 83 Large-surface radio pneumatic switch, 86 Light switch, 81 Light switching, 50 Location light, 10, 68, 69, 70, 72, 73, 77, 80, 81 Logging, 3, 38, 41 Logical group, 20, 25, 27, 36 Lounge with speech, 58 without speech, 60 M Magnetic wall bracket, 85 Main console, 68 Management Interface, 4, 34, 37, 38, 39, 41, 44, 92 Medical monitoring device, 9 Mobile phone, 21 Mounting kit for terminal or GE, 68, 69, 70, 71, 91 N NC contact, 32 NO contact, 32 Null modem cable, 92 Nurse call system configuration, 41 Nursing staff, 7 P Parked call, 30 Parking, 17, 30 Parking a call, 17, 30 Patient / Resident room, 68 with speech, 46 without speech, 48 PC, 89 Pear push switch, 4, 9, 16, 80, 81, 82 Pear push switch incl. 2 call switches, 3 m, 81 Pear push switch incl. 3 call buttons, 3 m, 47, 49, 59, 61, 63 Pear push switch incl. call and light switch, 81 Pear push switch incl. call and light switch, 3m, 47, 49 Pear push switch incl. call switch, 3 m, 47, 49, 59, 61, 63, 81 Personal Computer, English, 89 Physical group, 34, 36 Plug-in call devices, 9, 80 PNC, 21, 22, 39, 44, 92 Pneumatic switch, 47, 54, 55, 57, 65, 79 Pneumatic switch, 4 16 Power requirement, 35 Power supply, 43, 45, 95 Power supply unit, 4, 35, 43, 96 Power supply unit 5A, 98 Power supply unit UPS, 95 Power supply unit UPS 60, 97 Power supply units, 95 Presence, 7, 8, 11, 13, 14, 17, 18, 44, 68, 69, 70 activate, 7 deactivate, 7 Presence button, 7, 8, 10, 68, 69, 70, 72,

105 11. Index Presence registration, 7, 70, 72, 73 Priority, 9, 11, 12, 14, 15, 31 Product overview, 67 Pull cord kit for terminal, 47, 52, 54, 57, 59, 63, 71 Pull cord switch, 4, 16, 47, 49, 54, 55, 57, 63, 65, 79 Pulse relay, 50 R RAB, 8, 9, 14, 18, 24, 32, 34, 37, 49, 53, 55, 57, 61, 66, 73 Radio call switch, 86 Radio paging system, 34 Radio receiver MHz, 85 Radio transmitter, 85 Reassurance light, 10, 43, 68, 69, 70, 72, 73, 77, 79, 80, 81 Red, 11, 68, 69, 70, 71, 72, 73, 74, 77, 80, 81 Reminder light, 8, 10, 68, 72, 73 Remote access, 34 Remote cancel button, 15, 17, 68, 69 Remote maintenance, 38 Remote maintenance module for ConLog PLUS, 88 Reporting, 41 Room, 47, 49, 51, 52, 53, 54, 55, 57, 59, 61 Room call, 9, 13, 14, 17, 28 Room lamp, 4, 8, 11, 43, 68, 69, 70, 74 Room lamp universal, 3 sections, 8, 47, 49, 51, 52, 53, 54, 55, 57, 59, 61, 66, 74 Room lamp universal, 3 sections, glass decor, 47, 49, 51, 52, 53, 54, 55, 57, 59, 61, 66, 74 Room lamp universal, 3 sections, with doorplate, 47, 49, 51, 52, 53, 54, 55, 57, 59, 61, 66, 74 Room no., 12, 15, 27, 41, 42, 68, 72 Room terminals, 8, 14, 16, 27, 34, 68, 69, 70, 72, 73 Inputs, 32 Room type, 15m 45 S Seat corner, 47, 49 Secondary line, 34, 37, 45 Self-releasing adapter pear push switch, 47, 49, 59, 61, Sensor mat CONCENTO, 84 Sensor mat with free cable ends, 87 Serial extension cable, 88, 93 Server, 38, 88 Shift, 3, 20, 25, 41, 90 Smoke detector, 9, 87 Software, 88 Sound detector, 83 Speaking to staff, 18 Specified times, 30 Speech communication, 35 Speech connection, 68, 69, 90 Speech direction control, 23 Speech line engaged, 17 Staff room, 9, 19, 51, 68 Staff room with HAB, 20 Surface mounting frame for mounting kit, 71, 91 Switches, 77 System control, 90 System limits, 37 System overview, 33 System safety, 43 System structure, 34 T Talk time, 30 Technology, 33 Telecare Control Centre, 21, 22, 39, 40, 41, 92 Telephone, 21, 35, 39, 43, 92 Telephone call, 9, 87 Telephone interface relay, 87 Telephone system, 4, 43 Telephony, 21, 34, 35, 43, 92 connection possibilities, 22 configuration, 25 technology, 39 Terminal S4 B, 8, 14, 17, 34, 35, 37, 63, 66, 70 Terminal S4 P, 8, 14, 17, 34, 35, 37, 47, 52, 54, 57, 59, 66, 69 Terminal SD6 P, 4, 7, 8, 9, 13, 14, 15, 17, 18, 19, 20, 27, 28, 34, 35, 37, 44, 47, 51, 52, 54, 57, 59, 66, 68 Terminals, 8, 9, 32, 41, 68 Text display, 22 Ticker-type text, 15 Time, 12, 15 Timeout, 30 Timezone, 15, 20, 25, 41, 68 U Uninterrupted power supply, 43 Universal button, 68 V Voice announcement, 22, 23 W Ward, 19, 20, 25, 33, 36, 41 Example, 4 Ward bathroom with speech, 54 without speech, 55 Ward bus, 34, 37, 39, 40, 44, 45, 68, 69, 70, 72, 73, 76, 90, 92 Ward speech, 39 Warning tone, 17 WC, 9, 11, 17, 18, 47, 49, 54, 55, 57, 63 WC call, 9, 13, 14, 17, 18, 24, 74, 77 WC cancel button, 10, 17, 32, 77 WC with multiple cubicles, 56 White, 11,

106 11. Index WILMA, 21, 22, 39, 44, 92 Windows, 42, 89 Wired call devices, 87 Wireless call devices, 85 Y Yellow, 7, 68,

107

108 Find all you want to know about the CONCENTO PLUS system: CONCENTO PLUS Data Sheet Catalogue CONCENTO PLUS System Description Order No CONCENTO PLUS Technical Manual Order No CONCENTO PLUS Operating Instructions Order No The documents are ready for downloading from the homepage: QUALITY MANAGEMENT SYSTEM DQS certified to DIN EN ISO 9001 Reg. no Reg. no Tunstall GmbH Orkotten Telgte Germany Tel. No.: +49 (0) Fax: +49 (0) CONCENTO PLUS System Description

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE Emergency Response System INSTALLATION & PROGRAMMING GUIDE Copyright micron 2005 Contents Product Description 3 Console Operation Overview 4 Console Wiring Diagram 5 User Manual 6 Transmitter Assembly

More information

Always on the Lookout Perfect Protection against Burglary

Always on the Lookout Perfect Protection against Burglary Always on the Lookout Perfect Protection against Burglary Terxon wired and hybrid alarm systems One system offers all possibilities Rely on experts With a qualified specialist installation contractor on

More information

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction 1. 2. Software Installation 2

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction 1. 2. Software Installation 2 1. Introduction 1 2. Software Installation 2 2.1 System Requirements 2 2.2 TroxMConnect Installation 2 2.3 Connection to the PC 3 3. TroxMConnect Description 4 3.1 Starting the Software 4 3.2 Layout 4

More information

F453. TiF453. User guide 10/11-01 PC

F453. TiF453. User guide 10/11-01 PC F453 TiF453 User guide 10/11-01 PC 2 TiF453 User guide Contents 1. Hardware and Software requirements 4 2. Installation 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements 4 3. Fundamental

More information

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS

More information

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: [email protected]

More information

Monitoring Network DMN

Monitoring Network DMN Monitoring Network DMN User Manual Table of contents Table of contents... 2 1. Product features and capabilities... 3 2. System requirements... 5 3. Getting started with the software... 5 3-1 Installation...

More information

Be ready for emergencies

Be ready for emergencies The pascom alarm server automatically forwards any danger alarms or technical emergencies to the responsible assistance team. pascom alarm server Be ready for emergencies We simplify your processes...

More information

TS510 & TS500. Installation & User Guide. Compatible Equipment

TS510 & TS500. Installation & User Guide. Compatible Equipment Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

1 Technical Description Lokal-200PC

1 Technical Description Lokal-200PC 1 Technical Description Lokal-200PC 1.1 Overview laptop with in-built accummulator USB connection correlator box internal power supply laptop (if the device has been supplied by F.A.S.T.) BNC aerial connection

More information

Scalability is the best solution. The new Social Alarm Management System 7 Professional.

Scalability is the best solution. The new Social Alarm Management System 7 Professional. Scalability is the best solution. The new Social Alarm Management System 7 Professional. 2 Efficiency through customising Ideal solutions for your success To ensure immediate responses to emergency calls,

More information

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

868 MHz. VdS. Original size Aluminium. The first ARGUS Smoke Detector System with VdS* approval. * Association of. Polar white.

868 MHz. VdS. Original size Aluminium. The first ARGUS Smoke Detector System with VdS* approval. * Association of. Polar white. Original size Aluminium 868 MHz VdS GEPRÜFT The first ARGUS Smoke Detector System with VdS* approval. * Association of 22 property insurers Polar white Dark brazil ARGUS SMOKE DETECTORS. Increased safety

More information

D200+ Auto-Dialler Installation/Operators Manual

D200+ Auto-Dialler Installation/Operators Manual D200+ Auto-Dialler Installation/Operators Manual Bell System (Telephones) Ltd. Presley Way, Crownhill, Milton Keynes, MK8 0ET D200+ Software Version 1.0 Contents General Description...3 Central Station

More information

How To Use A Power Supply On A Powerline 2.2 (Ai)

How To Use A Power Supply On A Powerline 2.2 (Ai) KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang

More information

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2 Installation and Operating Manual p. 23 Radio push button 2 channel: HM-PB-2-WM55-2 1. English edition 10/2013 Documentation 2013 eq-3 Ltd., Hong Kong All rights reserved. No parts of this manual may be

More information

Wireless Home Security System Product Manual (Model #80355)

Wireless Home Security System Product Manual (Model #80355) Wireless Home Security System Product Manual (Model #80355) Installation Instructions During set-up, if no key is pressed for 15 seconds it will come out of the setup mode and you will have to start over.

More information

9452/9453 Installation and User Guide

9452/9453 Installation and User Guide 9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and

More information

Business/Home. GSM Alarm system

Business/Home. GSM Alarm system Business/Home GSM Alarm system Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. I. General information: GSM 900/1800/1900

More information

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating GB PKN10 serial node with colour LCD display User s manual Bač 49a, 6253 Knežak, SLOVENIA tel: ++ 386 5 753 2006 fax: ++ 386 5 753 2007 email: [email protected] http://www.secelectro.com SEC Electronics

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

Automatic Telephone Dialer TD-101(W)

Automatic Telephone Dialer TD-101(W) Automatic Telephone Dialer TD-101(W) The TD-101 is an automatic dialing device which can transmit prerecorded information via the telephone line. The dialer can send two different 10 second voice messages

More information

IP PBX system USER MANUAL. ver. 2.01.02

IP PBX system USER MANUAL. ver. 2.01.02 IP PBX system USER MANUAL ver. 2.01.02 Platan Prima IP PBX is a product manufactured by: PLATAN Sp. z o.o. sp.k., 81-855 Sopot, ul. Platanowa 2, Poland tel. +48 58 555 88 00, fax +48 58 555 88 01 e-mail:

More information

Alert, inform, react Aastra Alarm Server

Alert, inform, react Aastra Alarm Server Alert, inform, react Targeted alarming on all communication channels The effective transfer of information is important to increase a company s success and customer satisfaction. Information can be passed

More information

Business/Home GSM Alarm System. Installation and User Manual

Business/Home GSM Alarm System. Installation and User Manual Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene

More information

ABUS WIRELESS ALARM SYSTEM

ABUS WIRELESS ALARM SYSTEM ABUS WIRELESS ALARM SYSTEM These installation instructions are published by Security-Center GmbH & Co. KG, Linker Kreuthweg 5, D-86444 Affing/Mühlhausen. All rights including translation reserved. Reproductions

More information

Security System User Guide

Security System User Guide Security System User Guide Contents 1. Introduction... 1 Controls and Displays... 3 Displays... 3 Controls:... 4 2. Everyday Operation... 5 Access to the System... 5 Entering and Leaving the Protected

More information

Intercall 600 & Intercall 700 Installation & Operation Guide Documentation Issue 4.32 www.intercall.co.uk

Intercall 600 & Intercall 700 Installation & Operation Guide Documentation Issue 4.32 www.intercall.co.uk Intercall 600 & Intercall 700 Installation & Operation Guide Documentation Issue 4.32 www.intercall.co.uk No part of this leaflet may be reproduced without prior written consent and while every effort

More information

How To Use A 1232 On A 1236 On A Computer Or A Cell Phone

How To Use A 1232 On A 1236 On A Computer Or A Cell Phone 12-36-1000 Autodialler and Relay Telephone Interface 1.0 INTRODUCTION 12-36-1000 I/O Telephone Interface with AutoDialer The 12-36-1000 is a autodialer and telephone interface that can be used autonomously

More information

Telecommunications Switching Systems (TC-485) PRACTICAL WORKBOOK FOR ACADEMIC SESSION 2011 TELECOMMUNICATIONS SWITCHING SYSTEMS (TC-485) FOR BE (TC)

Telecommunications Switching Systems (TC-485) PRACTICAL WORKBOOK FOR ACADEMIC SESSION 2011 TELECOMMUNICATIONS SWITCHING SYSTEMS (TC-485) FOR BE (TC) PRACTICAL WORKBOOK FOR ACADEMIC SESSION 2011 TELECOMMUNICATIONS SWITCHING SYSTEMS (TC-485) FOR BE (TC) Department of Electronic Engineering NED University of Engineering and Technology, Karachi LABORATORY

More information

Combi B PC software 8213X. Installation and operating instructions

Combi B PC software 8213X. Installation and operating instructions Combi B PC software 8213X Installation and operating instructions EN Table of Contents 1 Important notes... 3 2 Glossary of abbreviations and terms... 4 3 Symbols and special font types used... 5 4 Scope

More information

LW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

LW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets LW-2000-3A Wireless Auto Dial Alarm System Sentry Plus User Manual By Global Gadgets Main Features Simple to use keypad for operation and control. The system can store up to 9 telephone numbers: positions

More information

Intruder Alarm System

Intruder Alarm System Intruder Alarm System GSM & PSTN Wireless and Wired Touch Model 2013-01 V1.0.0 Statment This equipment must be installed and used in strict accordance with the instructions given in this user documentation.

More information

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand Elite 8D/Lite Version 8 Zone Controller 8 Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand 2 CONTENTS Page No. INTRODUCTION 4 About your Alarm 4 OPERATING

More information

Inwall 4 Input / 4 Output Module

Inwall 4 Input / 4 Output Module Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...

More information

computer radio control system

computer radio control system extended serie Receivers 1 Introduction GLISH FW. ver. 3.10 Jeti DUPLEX Receivers are designated for use with the DC/DS transmitters or the JETI transmitter modules in the 2,4 GHz frequency band. DUPLEX

More information

UM-X Field display for continous level sensors

UM-X Field display for continous level sensors Technical Documentation Field display for continous level sensors 10/2007 Edition: 1 Item No.: 207120 FAFNIR GmbH Bahrenfelder Str. 19 D-22765 Hamburg Telephone: +49 (0)40-39 82 07-0 Fax: +49 (0)40-3 90

More information

Personal Assistance System Owner's Guide

Personal Assistance System Owner's Guide Owner's Guide PSC07 READ THIS FIRST This equipment generates and uses radio frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturers instructions,

More information

Voice alarm system E100 the new standard for safe evacuation

Voice alarm system E100 the new standard for safe evacuation Voice alarm system E100 the new standard for safe evacuation Clear announcements and future-proof protection in case of fire Answers for infrastructure. E100 from Siemens so everyone knows what to do when

More information

Polycom SoundPoint IP 550

Polycom SoundPoint IP 550 Polycom SoundPoint IP 550 User Guide For training/documentation, please visit us @ http://customertraining.verizonbusiness.com or call 1 800 662 1049 2009 Verizon. All Rights Reserved. The Verizon and

More information

Dialog 4220 Lite/Dialog 4222 Office

Dialog 4220 Lite/Dialog 4222 Office Dialog 4220 Lite/Dialog 4222 Office System telephones for MD110 Communication System User Guide Flinders University Table of Contents Description 2 Incoming Calls... 10 Outgoing Calls... 12 During Calls

More information

How To Program An Autodialer

How To Program An Autodialer GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

AXIS Camera Station Quick Installation Guide

AXIS Camera Station Quick Installation Guide AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera

More information

Operating Instructions. Keypad 2605..

Operating Instructions. Keypad 2605.. Operating Instructions Keypad 605.. Contents Device description...4 Device presentation...5 Areas of application...6 Operation...8 Acknowledgement signals... 10 Start-up sequence... 11 Connection terminals...1

More information

CAPTAIN 6. USER GUIDE System ver. 6.0. 6 Zones Intruder Alarm System. PIMA Electronic Systems Ltd. www.pima-alarms.com

CAPTAIN 6. USER GUIDE System ver. 6.0. 6 Zones Intruder Alarm System. PIMA Electronic Systems Ltd. www.pima-alarms.com CAPTAIN 6 6 Zones Intruder Alarm System USER GUIDE System ver. 6.0 PIMA Electronic Systems Ltd. www.pima-alarms.com P/N 4410049, G2 XX en, Jan. 2010 2 CAPTAIN 6 User Guide SAFETY INSTRUCTIONS Your CAPTAIN-i

More information

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries. www.lonix.com

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries. www.lonix.com Guest Room Controls & Monitoring System Integrated Solution for Hotels Southern Countries www.lonix.com GUEST ROOM CONTROLS & MONITORING SYSTEM INDEX 1 GENERAL... 3 1.1 SYSTEM INTEGRATION... 3 1.2 USER

More information

Home Security Alarm System

Home Security Alarm System Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better

More information

JKW-IP. IP Video Entry System. QuikStart Guide

JKW-IP. IP Video Entry System. QuikStart Guide 1210 JKW-IP IP Video Entry System QuikStart Guide This is an abbreviated instruction manual for installation purposes. Please see the JKW-IP Installation Manual and JKW-IP Operation Manual for complete

More information

500r+ Installation and User Guide

500r+ Installation and User Guide 500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and

More information

Ericsson W25. Mobile Networks. Quick Installation Guide

Ericsson W25. Mobile Networks. Quick Installation Guide Ericsson W25 Fixed Wireless Terminal for WCDMA/HSDPA Mobile Networks Quick Installation Guide Table of Contents INTRODUCTION... 3 Package Contents... 3 Requirements... 3 INSTALLATION... 4 Unit Preparation...

More information

Clino Call DECTplus. Wireless communication

Clino Call DECTplus. Wireless communication Clino Call DECTplus Wireless communication System overview Clino Call DECTplus is a cordless communication solution that can be extended significantly both with respect to its expansion options as well

More information

Destiny 4100. Destiny 4100. Owners Manual

Destiny 4100. Destiny 4100. Owners Manual Destiny 4100 Destiny 4100 Owners Manual TABLE OF CONTENTS INTRODUCTION Control Panel...3 Detection Devices...3 Telephone Keypads...3 GLOSSARY... 4-5 LOCAL PHONE ACCESS Using Your Telephones As Keypads...6

More information

Business/Home GSM. Alarm System(III) Installation and Users guide

Business/Home GSM. Alarm System(III) Installation and Users guide Business/Home GSM Alarm System(III) Installation and Users guide I. General information: GSM 900/1800/1900 bands, can be used all over the world. Full duplex communication with the base. Monitor environment

More information

Installation and programming guide. Lifeline Connect and Connect+ D5307013B Version 9.7

Installation and programming guide. Lifeline Connect and Connect+ D5307013B Version 9.7 Installation and programming guide Lifeline Connect and Connect+ D5307013B Version 9.7 Contents Installation and Programming Guide Installation Guide...3 What s in the box...3 Your home unit...4 Front

More information

TCR easy Plus Alarm. Operating Instructions

TCR easy Plus Alarm. Operating Instructions TCR easy Plus Alarm Operating Instructions Table of Contents General.....................................4 Installation...................................5 Putting into Operation............................5

More information

PRODUCT WARRANTY. Page 20

PRODUCT WARRANTY. Page 20 PRODUCT WARRANTY Manufactured equipment is warranted to be free from defects in material and workmanship for a period of twelve (12) months from date of manufacture as indicated by the date stamp and/or

More information

Operating Instructions. Telephone System tiptel 1/8 fax clip tiptel 2/8 clip. (Release 2) tiptel

Operating Instructions. Telephone System tiptel 1/8 fax clip tiptel 2/8 clip. (Release 2) tiptel Operating Instructions (UK) Telephone System tiptel 1/8 fax clip tiptel 2/8 clip (Release 2) tiptel Table of Contents Connection of 8 extensions..........3 Connection of 7 extensions and 1 door intercom................4

More information

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the

More information

BlackHawk for MAC Software User Guide

BlackHawk for MAC Software User Guide BlackHawk for MAC Software User Guide Products: BLK-DH2 Series and BLK-HD Series DVRs Please read this manual before using your software, and always follow the instructions for safety and proper use. Save

More information

DC-8706K Auto Dial Alarm System

DC-8706K Auto Dial Alarm System DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power

More information

GB Gira nurse call system Plus Planning, installation, start-up, operation. Gira Nurse Call System Plus System manual

GB Gira nurse call system Plus Planning, installation, start-up, operation. Gira Nurse Call System Plus System manual GB Gira nurse call system Plus Planning, installation, start-up, operation Gira Nurse Call System Plus System manual Contents Contents Contents... 3 1. Introduction... 9 1.1 General Information... 9 1.2

More information

Light scene push button 8gang comfort flush-mounted 751688xx

Light scene push button 8gang comfort flush-mounted 751688xx 751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional

More information

Mitel IP Phone User Reference Guide Release 5.0

Mitel IP Phone User Reference Guide Release 5.0 830 Parkview Drive North, El Segundo, CA 90245 Tel: 310 747 3232 Fax: 310 747 3233 WWW.UNIVOIP.COM OfficeConnect Mitel IP Phone User Reference Guide Release 5.0 Note: The information contained in this

More information

4 Starts to flash when the system triggers an alarm/fault

4 Starts to flash when the system triggers an alarm/fault 1 4 Starts to flash when the system triggers an alarm/fault Emergency button if programmed 2 Deactivate 1 Activate 3 Partly Activate Note: The buttons on the wireless key fob are sensitive. Kindly handle

More information

IMPORTANT NOTICE CONCERNING EMERGENCY 911 SERVICES

IMPORTANT NOTICE CONCERNING EMERGENCY 911 SERVICES IMPORTANT NOTICE CONCERNING EMERGENCY 911 SERVICES Your service provider, not the manufacturer of the equipment, is responsible for the provision of phone services through this equipment. Any services

More information

Voice Over Internet Protocol (VoIP) Configuration

Voice Over Internet Protocol (VoIP) Configuration (VoIP) Configuration ENGINEERING REPORT No: 02-003 Introduction This report describes interfacing the IPCS VoIP Gateway Model EGW-902 to an ESTeem Model 192E Wireless Ethernet radio modem in a demonstration

More information

Mureva Assembly surface mounted wiring devices

Mureva Assembly surface mounted wiring devices 1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label

More information

Polycom SoundPoint IP 650

Polycom SoundPoint IP 650 Polycom SoundPoint IP 650 User Guide For training/documentation, please visit us @ http://customertraining.verizonbusiness.com or call 1 800 662 1049 2009 Verizon. All Rights Reserved. The Verizon and

More information

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack Access codes Contents Unset system indications - - - - - - - - - - - System indication - - - - - - - - - - - - Access codes - - - - - - - - - - - - - - - - How to operate Personal - - - - - - How to unset

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Function Description Ascom IP-DECT System

Function Description Ascom IP-DECT System Function Description Contents 1 Introduction... 1 1.1 Abbreviations and Glossary... 1 2 Technical Solution... 2 2.1 System Size... 2 2.2 LDAP Server... 3 2.3 Supported Protocols... 3 2.4 Power the Base

More information

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,

More information

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS stam-irs_en 01/11 STAM-IRS is a dedicated server to be used with the STAM-2 monitoring station which enables receiving transmissions sent via telephone

More information

Weather Direct Displays show Lost Forecast (blank boxes in the picture icons)

Weather Direct Displays show Lost Forecast (blank boxes in the picture icons) Weather Direct Displays show Lost Forecast (blank boxes in the picture icons) Many routine events can cause a Lost Forecast situation. Examples include: Power outage Change batteries Internet down in your

More information

Current Monitoring Kit QUICK START GUIDE

Current Monitoring Kit QUICK START GUIDE Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...

More information

WEB log. Device connection plans

WEB log. Device connection plans WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20151210* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,

More information

Possum HC2006 SERO! Telephone. Firmware Upgrade and Software Manual firmware version 2.00+

Possum HC2006 SERO! Telephone. Firmware Upgrade and Software Manual firmware version 2.00+ Possum HC2006 SERO! Telephone Firmware Upgrade and Software Manual firmware version 2.00+ POSSUM LIMITED, 2009 8 FARMBROUGH CLOSE STOCKLAKE PARK INDUSTRIAL ESTATE AYLESBURY BUCKS HP20 1DQ TELEPHONE (from

More information

Product Information Fire alarm panel 8000 C

Product Information Fire alarm panel 8000 C Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.

More information

ACE AUTODIALLER MANUAL FOR LIFT COMPANY

ACE AUTODIALLER MANUAL FOR LIFT COMPANY ACE AUTODIALLER MANUAL FOR LIFT COMPANY 1 2 Information to the Building Owner. In June 2003 the harmonised standard BSEN81-28 came into effect. The standard states that it is the building owners responsibility

More information

SPECIAL CONTROL BUTTON FUNCTIONS

SPECIAL CONTROL BUTTON FUNCTIONS Operating Guide 1 2 3 CONTENTS Page No. OPERATING YOUR ALARM 5 General Information 5 Arming the Alarm 5 Disarming the Alarm 6 Arming in Stay Mode 7 Disarming Stay Mode 8 Bypassing Zones 8 Manual Panic,

More information

UsbCom Standard / Professional Software

UsbCom Standard / Professional Software Operating instructions UsbCom Standard / Professional Software 3759562 Version 2.1 0612 Contents Introduction...3 Installation...3 Start program...4 Menu bar and configuration...5 1. Program...5 1.1 Close

More information

Current Monitoring Kit

Current Monitoring Kit Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added

More information

Engineering and service software For KNX and LPB plants

Engineering and service software For KNX and LPB plants 5 649 Engineering and service software For KNX and LPB plants As of V9.00 ACS790 The engineering and service software ACS790 is for KNX and LPB plants equipped with the appropriate bus devices. The software

More information

Touch Tone Controller. Model TR16A. Owner s Manual

Touch Tone Controller. Model TR16A. Owner s Manual Touch Tone Controller Model TR16A Owner s Manual CONTENTS IMPORTANT NOTICE Features... 2 Introduction... 2 Important Notice...3 How it Works... 4 Installation... 4 Operation a... 5 From the Touch Tone

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control

More information

NortechCommander Software Operating Manual MAN-00004 R6

NortechCommander Software Operating Manual MAN-00004 R6 NortechCommander Software Operating Manual MAN-00004 R6 If the equipment described herein bears the symbol, the said equipment complies with the applicable European Union Directive and Standards mentioned

More information

GSM COMMUNICATORS CATALOGUE

GSM COMMUNICATORS CATALOGUE COMMUNICATORS CATALOGUE ( ) 870020/B - 07/2007 - Daitem - ATRAL SYSTEM S.A.S. - R.C.S. Grenoble 311 586 382 The services and product data presented in this document may be modified without prior notice

More information

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT CONTENTS Page INTRODUCTION... 2 Security conditions... 3 Full Set (Fully armed)... 3 Part Set (Partially armed)... 3 Unset (Disarmed)...

More information

Users Guide to Keypad Functions

Users Guide to Keypad Functions Users Guide to Keypad Functions MANUAL NO. 700-175-01J ISSUED JAN 2002 VERSION 1.41 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Panic Fire Medical Away Arm Stay Arm Stay Arm &

More information

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ-100 08E55-SHJ-100. 2004 American Honda Motor Co., Inc. - All Rights Reserved.

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ-100 08E55-SHJ-100. 2004 American Honda Motor Co., Inc. - All Rights Reserved. Kit No. 08E5-SHJ-00 08E55-SHJ-00 Security System Owner s Manual ODYSSEY 004 American Honda Motor Co., Inc. - All Rights Reserved. Contents Introduction... 3 Emergency Disarming During the Panic Alarm Activation...

More information

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM Page 0 Table of Contents Introduction 1 System Basics.. 1 Burglary Protection.. 1 Fire Protection.. 1 Security Codes. 1 Zones and Partitions

More information

FältCom ECII Flex Manual. Version: 0.2.4-C Updated: 2010-12-15. 162187 Manual FältCom ECII Flex Page 1 of 42

FältCom ECII Flex Manual. Version: 0.2.4-C Updated: 2010-12-15. 162187 Manual FältCom ECII Flex Page 1 of 42 FältCom ECII Flex Manual Version: 0.2.4-C Updated: 2010-12-15 162187 Manual FältCom ECII Flex Page 1 of 42 162187 Manual FältCom ECII Flex Page 2 of 42 Table of contents 1 NOTES... 5 2 COPYRIGHT... 5 3

More information

466-1936 Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: 60-883-95R. CareGard. User Guide

466-1936 Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: 60-883-95R. CareGard. User Guide ) *(6HFXULW\ 466-1936 Rev E October 2004 ZZZ*(6HFXULW\FRP Part No: 60-883-95R CareGard User Guide FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by GE Security

More information

CONCIERGE SWITCHBOARD

CONCIERGE SWITCHBOARD SECTION 4D CONCIERGE SWITCHBOARD Download from www.urmet.com Technical Manuals area. INDICE DI SEZIONE Ref. 1083/40 2 LIST OF DETAILS...2 Keypad...2 Ringer...2 Display...2 DESCRIPTION OF CONNECTIONS...2

More information

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP4-101. 2004 American Honda Motor Co., Inc. - All Rights Reserved. 1

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP4-101. 2004 American Honda Motor Co., Inc. - All Rights Reserved. 1 OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 8E5-EP4-24 American Honda Motor Co., Inc. - All Rights Reserved. Contents Introduction... 3 Emergency Disarming During Alarming... 4 During the Entry Delay

More information

Reliable Security Solutions

Reliable Security Solutions Reliable Security Solutions Challenger10 The proven solution for access control, intrusion detection and video integration. An integrated security solution for your most challenging environments The Tecom

More information