Basic Renewable Energy Training System
|
|
|
- Brice Thomas
- 10 years ago
- Views:
Transcription
1 Basic Renewable Energy Training System LabVolt Series Datasheet Festo Didactic en 220 V - 50 Hz 01/2016
2 Table of Contents General Description 2 Courseware 3 Modular Design Approach 4 Features & Benefits 4 List of Equipment 4 List of Manuals 5 Table of Contents of the Manual(s) 5 Optional Equipment 6 Additional Equipment Required to Perform the Exercises 6 Optional Manual(s) 6 System 6 Equipment Description 7 Optional Equipment Description 26 General Description The Basic Renewable Energy Training System provides in-depth coverage of basic renewable energy systems. It provides an introduction to dc power circuits, and covers in detail the principles behind the production of electrical energy from both solar power and wind power. Finally, the training system introduces students to the storage of electrical energy produced from renewable resources into lead-acid batteries for future consumption. The Basic Renewable Energy Training System is part of the Electric Power Technology Training Systems, Series Each training system in Series 8010 is based on the Electric Power Technology Training Program and provides a turn-key solution dealing with some aspects of the wide field of electrical energy. The exhaustive courseware provided with each training system covers all the theory required to perform the laboratory exercises, while review questions and unit tests allow students to test the knowledge they have gained. The Electric Power Technology Training Program is highly modular in both courseware and hardware. Because of this, courses and equipment from the program are available as required, either individually or in the context of a specific training system. The program covers several different subjects in the field of electrical energy, such as rotating machines, electrical power transmission, power electronics, home energy production from renewable resources (wind and sunlight), large-scale electricity production from hydropower and wind power, smart-grid technologies (SVC, STATCOM, HVDC transmission, etc.), storage of electrical energy in batteries, and drive systems for small electric vehicles and cars. 2 Festo Didactic
3 The above chart shows all courses in the Electric Power Technology Training Program. Blue boxes highlight courses included in the training system covered in this datasheet, while dark grey boxes, if any, highlight courses that can be optionally added to this training system. Courseware Each course in the training system includes a full-color student manual providing all the theoretical matter required, guided lab-exercise procedures to be performed with the training equipment, and review questions that test the knowledge gained by the student. Whenever possible, each course is built to bring the student to actual applications as soon as possible. A full-color instructor guide providing all lab results and answers to questions is also included with each course. Festo Didactic 3
4 Modular Design Approach The modular approach for designing the training program and lab equipment enables instructors to start building their electrical-energy laboratory with a basic package of courses and equipment and add new courses and equipment over time without needless duplication of equipment. All lab equipment consists of modules that can be inserted into a workstation. Module dimensions vary between two standard EMS sizes: full-size and half-size. Symbols and diagrams representing the electrical components in each module are clearly silk-screened on the front panel. Standard, color-coded safety banana jacks are used to provide access to the various components in each module. Features & Benefits The training system teaches the principles of electricity generation from renewable energy sources (solar power and wind power), as well as its subsequent storage in lead-acid batteries. The course curriculum of the Electric Power Technology Training Program is highly flexible and allows a multitude of different customized training solutions. The courseware includes student manuals and instructor guides with all the theory required to perform the hands-on experiments. All workstations, modules, and components are very sturdy to ensure a prolonged service life in a demanding environment such as a training laboratory. The modular design approach of the training equipment allows a large variety of courses to be performed using a small number of modules, without unnecessary duplication of equipment. All electrical components can be interconnected without electric shock hazard since all live parts of the connection leads are concealed and insulated. All electrical symbols representing the components used in a laboratory exercise are clearly silk-screened on the front panel of the modules. The training system includes a highly versatile USB peripheral: Four-Quadrant Dynamometer/Power Supply, Model This module is used as a dc power source and a battery charger/discharger with a large variety of configurable parameters. It is also used to simulate different wind conditions through a large variety of configurable parameters. Firmware upgrades for the Four-Quadrant Dynamometer/Power Supply are available for download free of charge on the Festo Didactic website. List of Equipment Qty Description Model number 1 Three-Module Workstation Wind Turbine Generator/Controller Resistive Load Lead-Acid Batteries Festo Didactic
5 Qty Description Model number 1 Lead-Acid Battery Pack Solar Panel Test Bench Monocrystalline Silicon Solar Panel Timing Belt Connection Lead Set 8951-L0 1 Four-Quadrant Dynamometer/Power Supply 8960-D5 List of Manuals Manual Description number Electric Power Technology Training Equipment (User Guide) E0 DC Power Circuits (Student Manual) DC Power Circuits (Instructor Guide) Lead-Acid Batteries (Student Manual) Lead-Acid Batteries (Instructor Guide) Solar Power (Student Manual) Solar Power (Instructor Guide) Introduction to Wind Power (Student Manual) Introduction to Wind Power (Instructor Guide) Table of Contents of the Manual(s) DC Power Circuits (Student Manual) ( ) 1 Voltage, Current, and Ohm s Law 2 Equivalent Resistance 3 Power in DC Circuits 4 Series and Parallel Circuits Lead-Acid Batteries (Student Manual) ( ) 1 Battery Fundamentals 2 Discharge Characteristics 3 Battery Charging Fundamentals 4 Battery Charging Methods Solar Power (Student Manual) ( ) 1 The Diode 2 The Solar Panel (Photovoltaic Panel) 3 Effect of Temperature on Solar Panel Performance 4 Storing Energy from Solar Panels into Batteries 5 Effect of Shading on Solar Panel Operation 6 Solar Panel Orientation 7 Solar Panel Performance versus Insolation Introduction to Wind Power (Student Manual) ( ) 1 Voltage-Versus-Speed Characteristic of a Wind Turbine Generator 2 Torque-Versus-Current Characteristic of a Wind Turbine Generator 3 Power Versus Wind Speed Festo Didactic 5
6 4 Storing the Energy Produced by Wind Turbines In Batteries Optional Equipment Qty Description Model number 1 1 Mobile Workstation Workstation Storage Shelves Full-Size Blank EMS Module Half-Size Blank EMS Module Wind Turbine Demonstrator 8216-D0 1 Multimeters Module A0 1 Pyranometer Magnetic Field Strength Indicator Wind Turbine Rotor Basic Renewable Energy Training System (Manuals on CD-ROM) A0 Additional Equipment Required to Perform the Exercises Qty Description Model number 2 Digital Multimeter Personal Computer Heavy-Duty Tripod Training on Introduction to Wind Power, 0.2 day TF Optional Manual(s) Model Qty Description number 1 Basic Renewable Energy Training System (Manuals on CD-ROM) A0 System Power Requirements Service Installation Computer Requirements Intended Location Dimensions (H x W x D) A standard single-phase ac outlet A currently available personal computer with USB 2.0 ports, running under one of the following operating systems: Windows 7 or Windows 8. On a table able to support the weight of the workstation and installed equipment 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in) TBE 1 Can replace the Three-Module Workstation, Model Can replace the Three-Module Workstation, Model Can replace the Digital Multimeter, Model Refer to the Computer Requirements in the System section of this datasheet if the computer is to be provided by the end-user. Note that only one computer is required per station. 5 Optional training at Festo Didactic Ltd. (Québec, Canada). Transportation, lodging and meals not included. For training at your site, please contact "[email protected]" for an estimate of extra travel fees that will apply. 6 Festo Didactic
7 EMS Modules Full-Size Dimensions (H x W x D) Half-Size Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in) Equipment Description Three-Module Workstation feet to protect the bench top. The Three-Module Workstation is a fully assembled workstation that serves the same purpose as the Mobile Workstation, Model 8110, but without any storage cabinet or pull-out work surface. This workstation is intended for use on a bench (not supplied) and is fitted with wooden The Three-Module Workstation consists of a single row of three full-height compartments that can accommodate up to three full-size EMS modules or six half-size EMS modules. Module Installation The EMS modules are guided into position along stainless steel guide rails. Separators between each bay of the workstation ensure perfect alignment of the EMS modules and allow their easy insertion in the workstation. A holding mechanism ensures that each EMS module stays in place once it is installed in a compartment of the workstation. A front-mounted push lever allows all EMS modules on the workstation to be released for easy removal. Safety Padlock Bars Two safety padlock bars on the front of the workstation prevent students from removing EMS modules during laboratory exercises. The bars can be removed and locked to the side of the workstation when the safety lock is not necessary. Festo Didactic 7
8 Additional Information Three holes in the rear panel of the workstation allow connection to a power supply, as well as the connection of 2 kw machines to their interconnection modules. Assembly of the workstation before painting ensures that each EMS module in the workstation is correctly grounded. Manual Manual Description number Electric Power Technology Training Equipment (User Guide) E0 Optional Equipment Qty Description Model number 1 Industrial Controls Single-Rail Workstation A0 1 Industrial Controls Double-Rail Workstation B0 1 Dust Cover for Workstation Intended Location Dimensions (H x W x D) On a table able to support the weight of the workstation and installed equipment 375 x 930 x 530 mm (14.8 x 36.6 x 20.9 in) TBE 6 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer to the 8036 datasheet for more information. 7 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer to the 8036 datasheet for more information. 8 Festo Didactic
9 Wind Turbine Generator/Controller rectifier, and power resistors. The Wind Turbine Generator/ Controller mainly consists of the generator and controller of an actual small-scale wind turbine, mounted in a full-size EMS module. The module also includes auxiliary components (a three-phase diode rectifier and a set of three power resistors) that can be used to apply a variable electric load to the generator. Color-coded, 4 mm safety banana jacks mounted on the front panel of the module provide access to the generator windings, controller input and output, diode The generator in the Wind Turbine Generator/Controller is a three-phase permanent-magnet synchronous generator. The controller is a power electronics device that converts the three-phase power produced by the generator into dc power and ensures that the generator produces the maximum amount of power possible at any wind speed within the operating range. The controller also performs voltage regulation to maintain a constant dc voltage output and prevents overcharging of the battery pack used to store the electrical energy produced by the wind turbine generator. A control knob on the module front panel allows the maximum charge voltage to be adjusted. A LED on the module front panel indicates the status (normal battery charging, voltage regulation, etc.) of the controller. Battery charging can be stopped anytime through a switch on the front panel. Resistive Load The Resistive Load consists of a halfsize EMS module housing nine wirewound power resistors arranged in three identical groups. Each group consists of three resistors connected in parallel that can be switched on or off with toggle switches to obtain various resistance values. This allows the total (equivalent) resistance of each group to be increased or decreased by steps. Six safety banana jacks on the module front panel provide access to each resistor group. The three resistor groups can be connected separately for operation in three-phase circuits. Also, the three resistor groups can be connected together for operation in single-phase circuits. The Resistive Load is commonly used in conjunction with other basic load modules, like the Inductive Load, Model 8321, and the Capacitive Load, Model 8331, to experiment with the effects of different types of load on a circuit. Festo Didactic 9
10 Resistors Quantity Resistance s (Each Group) Nominal Voltage Resistance Accuracy ± 5% Load at Nominal Voltage (Group) Power Current Steps Current Increment Dimensions (H x W x D) Lead-Acid Batteries Three identical groups of three resistors 1100/2200/4400 Ω 220 V ac/dc W A Seven, of equal increment 0.05 A 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in) 4.5 kg (9.9 lb) The Lead-Acid Batteries module consists of two 12 V valve-regulated, lead-acid (VRLA) batteries enclosed in a half-size EMS module. These batteries are part of the Electric Power Technology Training Program and are used to study lead-acid battery characteristics as well as the storage of electrical energy in various applications, such as solar power and wind power electricity generation. They can easily be charged using the Four-Quadrant Dynamometer/Power Supply, Model The batteries can be connected in series or parallel. Connection to the batteries is through 4 mm safety banana jacks mounted on the front panel of the module. These jacks are used when large amounts of power are supplied to the batteries or drawn from the batteries. A pair of miniature (2 mm) banana jacks mounted on the front panel of the module provides access to one of the two batteries via a low-capacity auto-reset fuse. These miniature jacks are used to connect the battery to either the Solar Panel Test Bench, Model 8805, or the Solar Panel, Model 8806, when performing lab exercises dealing with the storage of electrical energy produced from solar power. Batteries Quantity 2 Type Voltage Capacity Maximum Charge Current Maximum Discharge Current Valve-regulated lead-acid 12 V 2.3 Ah 0.92 A 5 A 10 Festo Didactic
11 Auto-Reset Protective Fuse Battery Test Point Dimensions (H x W x D) 5 A (hold current), 10 A (trip current) 0.1 A (hold current), 0.2 A (trip current) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in) 4.6 kg (10.2 lb) Lead-Acid Battery Pack The Lead-Acid Battery Pack is a halfsize EMS module housing four 12 V lead-acid batteries connected in series. The Lead-Acid Battery Pack thus provides a fixed dc voltage of 48 V, available at two color-coded safety banana jacks on the module front panel. Three battery voltage test points allow measurement of the voltage provided by each of the four 12 V batteries. A parallel charging input terminal permits the charging of several Lead Acid Battery Packs connected in parallel at the same time. The Lead-Acid Battery Pack is protected against overcurrents and short-circuits by electronic fuses that reset automatically. The Lead-Acid Battery Pack can be used as a 48 V dc power source, and in energy production and storage applications implemented with the Electricity and New Energy Training Equipment. Battery Pack Type Voltage Capacity Maximum Charge Current Maximum Discharge Current Parallel Charging Input Auto-Reset Protective Fuses Battery Pack Test Points (3) Dimensions (H x W x D) 4 valve-regulated lead-acid batteries 48 V (12 V for each battery) 9 Ah 2.7 A 7 A 58 V maximum 7 A (hold current), 14 A (trip current) 0.2 A (hold current), 0.4 A (trip current) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in) TBE Festo Didactic 11
12 Solar Panel Test Bench The Solar Panel Test Bench is a fullsize EMS module in which a Solar Panel, Model 8806 can be installed to perform a wide variety of tests and experiments. A powerful halogen lamp is used to illuminate the solar panel under test. The distance between the halogen lamp and solar panel can be changed to adjust the irradiance. A ventilation system is provided in the Solar Panel Test Bench to keep the solar panel at near room temperature and study the effects of temperature. The halogen lamp and ventilation system can be turned on and off through switches mounted on the front panel of the test bench. Pilot lamps on the front panel indicate the status (on or off) of the halogen lamp and ventilation system. The complete Solar Panel Test Bench is powered by a standard wall outlet. A potentiometer and a set of diodes are included in the Solar Panel Test Bench. The potentiometer is used to apply a variable electrical load to the output of the solar panel under test. The diodes can be connected to the solar panel to serve as either bypass diodes or blocking diodes. Access to the potentiometer and diodes is through miniature (2 mm) banana jacks mounted on the front panel of the test bench. Four other miniature banana jacks on the front panel of the test bench provide direct access to the output terminals of the solar panel to make connections easy. A set of connection leads terminated with miniature banana plugs is provided with the Solar Panel Test Bench. Power Requirements Current Service Installation Halogen Lamp Power Ventilation System Flow Rate Potentiometer Diodes Quantity 3 Peak Inverse Voltage Maximum Current Dimensions (H x W x D) 1.5 A Standard single-phase outlet TBE TBE Single Turn 500 Ω 2 W 1000 V 1 A 308 x 291 x 440 mm (2.1 x 11.5 x 17.3 in) 6.9 kg (15.2 lb) 12 Festo Didactic
13 Monocrystalline Silicon Solar Panel The Monocrystalline Silicon Solar Panel consists of two independent photovoltaic (PV) modules mounted on a common metal chassis that can be installed in the Solar Panel Test Bench, Model 8805, when performing exercises indoors, or on a tripod when performing exercises outdoors. Both PV modules are made of high-quality monocrystalline silicon cells and protected by a coat of clear glass epoxy. Independent access to the output of each PV module is provided via a pair of miniature (2 mm) banana jacks mounted on the solar panel chassis to allow either series or parallel connection of the PV modules. A multi-pin connector on the solar panel chassis allows connection of the PV module outputs to four miniature banana jacks on the front panel of the Solar Panel Test Bench to allow PV module connection from the outside of the workstation. Indoor Operation in the Solar Panel Test Bench A digital thermometer attached to the solar panel chassis allows the temperature of the PV modules to be monitored. A transparent window in the front panel of the Solar Panel Test Bench allows temperature monitoring even when the solar panel is installed in the test bench. Monocrystalline Silicon Solar Panel installed in the Solar Panel Test Bench (setup for indoor exercises). Festo Didactic 13
14 Outdoor Operation On a Tripod Monocrystalline Silicon Solar Panel installed on a tripod (setup for outdoor exercises). The surface of the metal chassis on which the PV modules lie is provided with a perpendicularly mounted metal pin and silk-screened angular markers. When performing exercises outdoors, the metal pin allows the orientation to be adjusted so that the solar panel is perfectly aimed at the Sun. The angular markers allow the solar panel orientation to be offset a certain angle with respect to the Sun direction when experimenting with solar panel orientation. The Monocrystalline Silicon Solar Panel includes a potentiometer and a set of diodes. The potentiometer is used to apply a variable electrical load to the output of the solar panel. The diodes can be connected to the solar panel to serve as either bypass diodes or blocking diodes. These components are used when performing solar panel exercises outdoors (i.e., without the Solar Panel Test Bench). Access to the potentiometer and diodes is through miniature (2 mm) banana jacks mounted on the solar panel chassis. PV Module Quantity 2 Type Monocrystalline Silicon Number of Cells 18 Open-Circuit Voltage (VOC) 9 STC Short-Circuit Current (ISC) 100 STC Potentiometer Single Turn Ω - 2 W Diodes Quantity 3 Peak Inverse Voltage 1000 V Maximum Current 1 A Thermometer Range -50 C to +150 C (-58 F to +302 F) Resolution ±0.1 from to , otherwise 1 Accuracy ±0.1 C from -30 C to +150 C (±1.8 F from -22 F to +302 F) Battery Voltage 1.5 V Battery Type A76 (LR44, G13) size or equivalent, 1 required Angular Markers Range Festo Didactic
15 Interval 5 Dimensions (H x W x D) Timing Belt x 237 x 58 mm (9.4 x 9.3 x 2.3 in) 2.0 kg (4.4 lb) adjacent EMS machines together without slippage between them. The Timing Belt is a high-quality industrial synchro-cog timing belt made of rubber whose teeth exactly mesh with the geared pulley fitted on the shaft of all 0.2 kw EMS machines. The Timing Belt is supplied in a fixed length appropriate for coupling two Pitch Pitch Length Number of Teeth 86 Dimensions (H x W x D) Connection Lead Set 8951-L0 9.5 mm (0.375 in) 819 mm (32.25 in) 120 x 120 x 20 mm (4.7 x 4.7 x 0.8 in) 0.1 kg (0.2 lb) This Connection Lead Set consists of extra-flexible leads terminated with stacking 4 mm safety banana plugs. In addition, the set includes stacking 2 mm banana plug leads of the same length and color. 4 mm Safety Banana Plug Leads Characteristics Cross Section Rated Current Rated Voltage 4 mm Safety Banana Plug Leads Quantities 2.5 mm² (4934 cmils) 32 A Yellow, 30 cm (12 in) 20 Red, 60 cm (24 in) 10 Blue, 90 cm (36 in) 4 2 mm Safety Banana Plug Leads Characteristics Cross Section 600 V, CAT II 0.5 mm² (987 cmils) Festo Didactic 15
16 Rated Current Rated Voltage 2 mm Safety Banana Plug Leads Quantities Red, 60 cm (24 in) 4 10 A 30 V ac / 60 V dc Four-Quadrant Dynamometer/Power Supply 8960-D5 The Four-Quadrant Dynamometer/ Power Supply is a highly versatile USB peripheral designed to be used in the Electric Power Technology Training Systems. Two operating modes are available: Dynamometer and Power Supply. A wide variety of userselectable functions is available in each operating mode. In the Dynamometer mode, the unit becomes a four-quadrant dynamometer that can act as either a fully configurable brake (i.e., a mechanical load) or a fully configurable prime mover (i.e., a motor drive). In the Power Supply mode, the unit becomes a four-quadrant power supply that can act as a dc voltage source, dc current source, ac power source, etc. In each operating mode, key parameters related to the selected function are displayed. Speed, torque, mechanical power, and energy are displayed in the Dynamometer mode while voltage, current, electrical power, and energy are displayed in the Power Supply mode. Optional functions, such as a small wind-turbine emulator, a hydraulic turbine emulator, a solar panel emulator, battery chargers, an SDK (Software Development Kit) etc., can be added to the standard functions to further enhance the training possibilities of the Four-Quadrant Dynamometer/Power Supply. Two modes are available to control the function which the Four-Quadrant Dynamometer/Power Supply performs: Manual and Computer-Based. In the Manual control mode, the module operates as a stand-alone unit, and the function performed is selected, set, and monitored using front-panel mounted controls and display. This mode provides access to all basic functions. In the Computer-Based control mode, the function performed by the module is selected, set, and monitored using the LVDAC-EMS software. In this mode, communication between the Four-Quadrant Dynamometer/Power Supply and the host computer running the LVDAC-EMS software is achieved through a USB connection. This mode provides access to all basic functions, as well as to additional advanced functions. Model 8960-D includes the Four-Quadrant Dynamometer/Power Supply, Model , with the following function sets activated: Standard Functions (Manual Control), Model Standard Functions (Computer-Based Control), Model Festo Didactic
17 Turbine Emulator, Model Lead-Acid Battery Charger, Model Additional Equipment Required to Perform the Exercises Model Qty Description number 1 8 Personal Computer Dynamometer Mode Magnetic Torque Direction of Rotation Speed Nominal Power Power Supply Mode DC Voltage AC Voltage (RMS) DC Current AC Current (RMS) Maximum Output Power AC Frequency Control Functions 0 to 3 N m (0 to 27 lbf in) CW / CCW 0 to 2500 r/min 350 W 0 to ± 150 V 0 to 105 V (no-load) 0 to ± 5 A 0 to 3.5 A 500 W 10 to 120 Hz Activated Sets Standard Functions (Manual Control), Model Liquid-Crystal Display (LCD) Control Inputs Command Input Standard Functions (Computer-Based Control), Model Turbine Emulator, Model Lead-Acid Battery Charger, Model mm (3 in), monochrome, background-illuminated, 240 x 160 dots 0 to ± 10 V Thermistor Input 10 kω, type 1 Control Outputs Shaft Encoder Torque Output Sensitivity Speed Output Sensitivity Quadrature encoder (A-B) pulses/revolution - TTL compatible 0.3 N m/v (2.655 lbf in/v) 500 r/min/v Communication Port USB 2.0 Power Requirements Computer Requirements Dimensions (H x W x D) 220 V - 3 A - 50 Hz, must include live, neutral, and ground wires A currently available personal computer with USB 2.0 ports, running under one of the following operating systems: Windows 7 or Windows x 287 x 490 mm (12.1 x 11.3 x 19.3 in) 19.5 kg (43.0 lb) 8 Refer to the Computer Requirements in the System section of this datasheet if the computer is to be provided by the end-user. Note that only one computer is required per station. Festo Didactic 17
18 Standard Functions (Manual Control) The Standard Functions (Manual Control) control function set is a package of control functions that can be activated in the Four-Quadrant Dynamometer/Power Supply, Model , enabling the module to perform a wide variety of functions in each of its two operating modes (Dynamometer and Power Supply). The set allows only manual control of the functions. This means that the Four-Quadrant Dynamometer/Power Supply operates as a stand-alone unit, and the function performed is selected, set, and monitored using frontpanel mounted controls and display. The following control functions are available in the set: Dynamometer operating mode Two-Quadrant, Constant-Torque Brake Clockwise Prime Mover/Brake Counterclockwise Prime Mover/Brake Clockwise Constant-Speed Prime Mover/Brake Counterclockwise Constant-Speed Prime Mover/Brake Positive Constant-Torque Prime Mover/Brake Negative Constant-Torque Prime Mover/Brake Power Supply operating mode Positive Voltage Source Negative Voltage Source Positive Current Source Negative Current Source 50 Hz Power Source 60 Hz Power Source Lead-Acid Battery Float Charger Control Functions Control Functions Two-Quadrant, Constant-Torque Brake Clockwise Prime Mover/Brake Counterclockwise Prime Mover/Brake Clockwise Constant-Speed Prime Mover/Brake Counterclockwise Constant-Speed Prime Mover/Brake Positive Constant-Torque Prime Mover/Brake Negative Constant-Torque Prime Mover/Brake 18 Festo Didactic
19 Two-Quadrant, Constant-Torque Brake Torque Clockwise/Counterclockwise Prime Mover/Brake Speed Clockwise/Counterclockwise Constant-Speed Prime Mover/ Brake Speed Positive/Negative Constant- Torque Prime Mover/Brake Torque Positive/Negative Voltage Source Voltage Positive/Negative Current Source Current 50 Hz/60 Hz Power Source No-Load Voltage 200 V DC Bus Status Lead-Acid Battery Float Charger Float Voltage Positive Voltage Source Negative Voltage Source Positive Current Source Negative Current Source 50 Hz Power Source 60 Hz Power Source 200 V DC Bus Lead-Acid Battery Float Charger 0-3 N m (26.55 lbf in) r/min r/min 0-3 N m (26.55 lbf in) 0 V to 147 V / -147 V to 0 V 0 A to 5 A / -5 A to 0 A V On or off V Festo Didactic 19
20 Standard Functions (Computer-Based Control) The Standard Functions (Computer- Based Control) control function set is a package of control functions that can be activated in the Four-Quadrant Dynamometer/Power Supply, Model , enabling the module to perform a wide variety of functions in each of its two operating modes (Dynamometer and Power Supply). The set allows only computer-based control of the functions. This means that the function performed by the Four-Quadrant Dynamometer/Power Supply is selected, set, and monitored using the LVDAC-EMS software. The following control functions are available in the set: Dynamometer operating mode Two-Quadrant, Constant-Torque Brake Clockwise Prime Mover/Brake Counterclockwise Prime Mover/Brake Clockwise Constant-Speed Prime Mover/Brake Counterclockwise Constant-Speed Prime Mover/Brake Positive Constant-Torque Prime Mover/Brake Negative Constant-Torque Prime Mover/Brake Four-Quadrant Constant-Speed Prime Mover/Brake Speed Sweep Power Supply operating mode Positive Voltage Source Negative Voltage Source DC Voltage Source Positive Current Source Negative Current Source DC Current Source 50 Hz Power Source 60 Hz Power Source AC Power Source Lead-Acid Battery Float Charger Control Functions Control Functions Two-Quadrant, Constant-Torque Brake Clockwise Prime Mover/Brake Counterclockwise Prime Mover/Brake 20 Festo Didactic
21 Two-Quadrant, Constant-Torque Brake Torque Control Torque Clockwise Constant-Speed Prime Mover/Brake Counterclockwise Constant-Speed Prime Mover/Brake Positive Constant-Torque Prime Mover/Brake Negative Constant-Torque Prime Mover/Brake Four-Quadrant, Constant-Speed Prime Mover/Brake Speed Sweep Mechanical Load Positive Voltage Source Negative Voltage Source DC Voltage Source Positive Current Source Negative Current Source DC Current Source 50 Hz Power Source 60 Hz Power Source AC Power Source Lead-Acid Battery Float Charger Software knob, 8960 module knob, or 8960 command input 0-3 N m (26.55 lbf in) Pulley Ratio 24:24, 24:12, or 24:32 Clockwise/Counterclockwise Prime Mover/Brake Speed Control Speed Software knob, 8960 module knob, or 8960 command input r/min Pulley Ratio 24:24, 24:12, or 24:32 Clockwise/Counterclockwise Constant-Speed Prime Mover/ Brake Speed Control Speed Software knob, 8960 module knob, or 8960 command input r/min Pulley Ratio 24:24, 24:12, or 24:32 Positive/Negative Constant- Torque Prime Mover/Brake Torque Control Torque Software knob, 8960 module knob, or 8960 command input 0-3 N m (26.55 lbf in) Pulley Ratio 24:24, 24:12, or 24:32 Four-Quadrant, Constant-Speed Prime Mover/Brake Speed Control Speed Software knob, 8960 module knob, or 8960 command input r/min Pulley Ratio 24:24, 24:12, or 24:32 Speed Sweep Festo Didactic 21
22 Start Speed r/min to 3000 r/min Finish Speed r/min to 3000 r/min Number of Steps 0-50 steps Step Duration 2-10 s Record Data to Table Yes or no Pulley Ratio 24:24, 24:12, or 24:32 Mechanical Load Load Type Flywheel, fan, grinder, conveyor, calender, crane, user defined Inertia kg m² ( lb ft²) Friction Torque N m ( lbf in) Pulley Ratio 24:24, 24:12, or 24:32 Positive/Negative Voltage Source Voltage Control Software knob, 8960 module knob, or 8960 command input Voltage 0 V to 147 V / -147 V to 0 V DC Voltage Source Voltage Control Software knob, 8960 module knob, or 8960 command input Voltage -147 V to 147 V Positive/Negative Current Source Current Control Software knob, 8960 module knob, or 8960 command input Current 0 A to 5 A / -5 A to 0 A DC Current Source Current Control Software knob, 8960 module knob, or 8960 command input Current -5 A to 5 A 50 Hz/60 Hz Power Source Voltage Control Software knob, 8960 module knob, or 8960 command input No-Load Voltage V AC Power Source No-Load Voltage V DC Offset Correction to 1000 Frequency Hz Lead-Acid Battery Float Charger Float Voltage V 22 Festo Didactic
23 Turbine Emulator The Turbine Emulator control function set is a package of control functions that can be activated in the Four- Quadrant Dynamometer/Power Supply, Model , enabling the module to emulate the operation of various types of turbines. The control functions in the set are only available in computer-based mode. This means that the function performed by the Four-Quadrant Dynamometer/Power Supply is selected, set, and monitored using the LVDAC-EMS software. The following control functions are available in the set: Dynamometer operating mode Small Wind-Turbine Emulator: this function makes the permanent-magnet dc motor of the Four-Quadrant Dynamometer/Power Supply faithfully reproduce the effect of wind on the bladed rotor of a small-scale wind turbine. The torque-speed characteristic at the shaft of the machine coupled to the Four-Quadrant Dynamometer/Power Supply is the same as the one that is obtained when wind blows at a certain speed on the rotor of the actual wind turbine. The user has control over the wind speed and air density. Hydraulic Turbine Emulator: this function uses the permanent-magnet dc motor of the Four-Quadrant Dynamometer/ Power Supply to recreate the behavior of an hydraulic turbine with a synchronous generator. The torque-speed characteristics at the shaft of the machine coupled to the Four-Quadrant Dynamometer/Power Supply is the same as that of a Francis-type hydraulic turbine. The user has control over the vane angle (manually or through the module analog input), the vane variation speed, and the inertia. Control Functions Control Functions Wind-Turbine Emulator Wind Control Wind Speed Air Density Wind Turbine Type Pulley Ratio Inertia J Gear Ratio R Wind-Turbine Emulator Hydraulic-Turbine Emulator Software slider or 8960 command input 3-12 m/s ( mph) kg/m³ ( lb/ft³) 1.15 m with 3 blades, 1.15 m with 3 blades and gearbox, 0.72 m with 3 blades and passive stall 24:24, 24:12, 24:32 (different pulley ratios are available depending on the wind turbine type) kg m² ( lb ft²) (only available for certain wind turbine types) (only available for certain wind turbine types) Festo Didactic 23
24 Hydraulic-Turbine Emulator Vane Control Turbine Type Vane Maximal Speed Runner Inertia Software slider or 8960 command input 300 W Francis 0-100%/s Pulley Ratio 24:24 Lead-Acid Battery Charger kg m² (7.119 lb ft²) The Lead-Acid Battery Charger control function set is a package of control functions that can be activated in the Four-Quadrant Dynamometer/Power Supply, Model , enabling the module to implement a lead-acid battery charger, as well as a battery discharger. The Lead-Acid Battery Charger control function is only available in computerbased mode. This means that the function performed by the Four- Quadrant Dynamometer/Power Supply is selected, set, and monitored using the LVDAC-EMS software. The following control functions are available in the set: Power Supply operating mode Lead-Acid Battery Charger (Fast): This function uses the four-quadrant power supply to implement a battery charger that is able to rapidly charge lead-acid batteries of various capacities (typically in less than two hours). A three-step charge algorithm is used. Battery charging starts with a constant current corresponding to the battery maximum charge current until the battery gassing voltage is reached. At this point, battery charging continues with a constant voltage (close to gassing voltage) until the charge current decreases to 0.1 C. Then, constant-voltage charging continues but at a lower voltage (float charging voltage). The user has to specify the following four battery characteristics for the charger to achieve proper charge control: maximum charge current, gassing voltage, 0.1C current (10% of battery capacity), and float charging voltage. The function indicates the voltage, current, electrical power, and energy at the charger output. The function can also indicate battery temperature when the temperature sensor of the battery (if so equipped) is connected to the Thermistor Input of the Four-Quadrant Dynamometer/Power Supply. The function can also indicate battery temperature when the temperature sensor of the battery (if so equipped) is connected to the Thermistor Input of the Four-Quadrant Dynamometer/Power Supply. The license for the Lead-Acid Battery Charger, Model , is required to activate the Lead-Acid Battery Charger (Fast) function in the Four-Quadrant Dynamometer/Power Supply. Battery Discharger (Constant-Current Timed Discharge with Voltage Cutoff): This function uses the four-quadrant power supply to sink a constant current from a battery, thereby discharging the battery at a specific rate, during a specific period. The discharger also monitors the battery 24 Festo Didactic
25 voltage during discharge. Battery discharging terminates immediately when the battery voltage decreases to a specific cutoff voltage. The user has to specify the discharge current, discharge duration, and cutoff voltage for the discharger to achieve proper discharge control. The function indicates the voltage, current, electrical power, and energy at the discharger output. The function can also indicate battery temperature when the temperature sensor of the battery (if so equipped) is connected to the Thermistor Input of the Four-Quadrant Dynamometer/ Power Supply. The Battery Discharger function is perfectly suited to measure discharge characteristics of batteries at various rates as well as to bring a battery to a specific depth of discharge before a battery charging experiment. The license for the Lead-Acid Battery Charger, Model , or the license for the Ni-MH Battery Chargers, Model , is required to activate the Battery Discharger (Contant-Current Timed Discharge with Voltage Cutoff) function in the Four-Quadrant Dynamometer/Power Supply. Control Functions Control Functions Lead-Acid Battery Charger (Fast) Maximum Charge Current Gassing Voltage Lead-Acid Battery Charger (Fast) Battery Discharger (Constant-Current Timed Discharge with Voltage Cutoff) 0-5 A V 0.1C Current 0-5 A Float Voltage Battery Discharger (Constant- Current Timed Discharge with Voltage Cutoff) Discharge Current Discharge Duration Cutoff Voltage V 0-5 A min V Festo Didactic 25
26 Optional Equipment Description Mobile Workstation (Optional) The Mobile Workstation is a ready-foruse workstation that consists of two fully assembled modules: a Workstation, Model , mounted on a Mobile Storage Cabinet, Model Four rubber-tire swivel casters allow easy movement of the workstation in the laboratory classroom. The lower portion of the workstation serves as a storage cabinet with two hinged panels and a lock handle. Immediately above the storage cabinet is a pullout work surface with a scuff- and burnresistant laminate finish. The upper portion of the workstation consists of three rows of compartments designed to house EMS modules. Two of these rows have full-height compartments while the other row has half-height compartments. Each row of full-height compartments can accommodate up to three full-size EMS modules or six half-size EMS modules, whereas the row of half-height compartments can accommodate up to three half-size EMS modules. Module Installation The EMS modules are guided into position along stainless steel guide rails. Separators between each bay of the workstation ensure perfect alignment of the EMS modules and allow their easy insertion in the workstation. A holding mechanism ensures that each EMS module stays in place once it is installed in a compartment of the workstation. Front-mounted push levers allow all EMS modules on a single row to be released for easy removal. 26 Festo Didactic
27 Safety Padlock Bars Two safety padlock bars on the front of the workstation prevent students from removing EMS modules during laboratory exercises. The bars can be removed and locked to the side of the workstation when the safety lock is not necessary. Additional Information Six holes in the rear panel of the workstation allow connection to a power supply, as well as the connection of 2 kw machines to their interconnection modules. Assembly of the workstation before painting ensures that each EMS module in the workstation is correctly grounded. Manual Manual Description number Electric Power Technology Training Equipment (User Guide) E0 Optional Equipment Qty Description Model number 1 Industrial Controls Single-Rail Workstation A Industrial Controls Double-Rail Workstation 3105-B0 Intended Location Dimensions (H x W x D) On the floor (stands on casters) 1790 x 940 x 665 mm (70.5 x 37.0 x 26.2 in) 77.1 kg (170 lb) 9 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer to the 8036 datasheet for more information. 10 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer to the 8036 datasheet for more information. Festo Didactic 27
28 Workstation (Optional) The Workstation is a fully assembled workstation that serves the same purpose as the Mobile Workstation, Model , but has no storage cabinet or pull-out work surface. This workstation is intended for use on a bench (not supplied) and is fitted with wooden feet to protect the bench top. Alternatively, this workstation can be mounted on either a Mobile Storage Cabinet, Model , to make a Mobile Workstation, Model , or on a Mobile Base, Model 88863, to make a mobile workstation without storage cabinet. In that case, it is possible to mount and lock a second Workstation, Model , on top of the first Workstation to double the space available for EMS modules. The Workstation consists of three rows of compartments designed to house EMS modules. Two of these rows have full-height compartments while the other row has half-height compartments. Each row of full-height compartments can accommodate up to three full-size EMS modules or six half-size EMS modules whereas the row of half-height compartments can accommodate up to three half-size EMS modules. Module Installation The EMS modules are guided into position along stainless steel guide rails. Separators between each bay of the workstation ensure perfect alignment of the EMS modules and allow their easy insertion in the workstation. A holding mechanism ensures that each EMS module stays in place once it is installed in a compartment of the workstation. Front-mounted push levers allow all EMS modules on a single row to be released for easy removal. 28 Festo Didactic
29 Safety Padlock Bars Two safety padlock bars on the front of the workstation prevent students from removing EMS modules during laboratory exercises. The bars can be removed and locked to the side of the workstation when the safety lock is not necessary. Additional Information Six holes in the rear panel of the workstation allow connection to a power supply, as well as the connection of 2 kw machines to their interconnection modules. Assembly of the workstation before painting ensures that each EMS module in the workstation is correctly grounded. Manual Manual Description number Electric Power Technology Training Equipment (User Guide) E0 Optional Equipment Qty Description Model number 1 11 Industrial Controls Single-Rail Workstation 3105-A Industrial Controls Double-Rail Workstation 3105-B0 1 Dust Cover for Workstations Mobile Base Mobile Storage Cabinet Intended Location Dimensions (H x W x D) On a table able to support the weight of the workstation and installed equipment 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in) 31.8 kg (70 lb) 11 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer to the 8036 datasheet for more information. 12 This add-on workstation allows modules from the Industrial Controls Training Systems, Models 8036, to be installed in the EMS workstation. Refer to the 8036 datasheet for more information. Festo Didactic 29
30 Storage Shelves (Optional) The Storage Shelves module contains five shelves, each of which can accommodate four full-size EMS modules or eight half-size EMS modules. Stainless steel rails guide the modules on the storage shelves and protect them against wear. The Storage Shelves module requires assembly. A diagram is provided to facilitate assembly. Optional Equipment Model Qty Description number 1 Dust Cover for Model Intended Location Dimensions (H x W x D) On the floor 1980 x 1225 x 480 mm (78 x 48.2 x 18.9 in) TBE 30 Festo Didactic
31 Full-Size Blank EMS Module (Optional) The Full-Size Blank EMS Module is used to fill unused locations in a workstation, preventing students from accessing electrical or moving parts inside the other modules. Combined with the use of safety bars to prevent students from removing modules, blank EMS modules ensure student safety during lab exercises. Dimensions (H x W x D) 308 x 287 x 440 mm (12.1 x 11.3 x 17.3 in) TBE Half-Size Blank EMS Module (Optional) safety during lab exercises. The Half-Size Blank EMS Module is used to fill unused locations in a workstation, preventing students from accessing electrical or moving parts inside the other modules. Combined with the use of safety bars to prevent students from removing modules, blank EMS modules ensure student Dimensions (H x W x D) 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in) TBE Festo Didactic 31
32 Wind Turbine Demonstrator (Optional) 8216-D0 The Wind Turbine Demonstrator is an actual small-scale wind turbine modified to display the main internal components. The wind turbine has a fixed-pitch, three blade rotor that is directly coupled to the generator. The wind turbine is mounted atop a sturdy metal pole at a height that facilitates observation of the internal components. Casters at the base of the metal pole makes the whole unit easy to move. The casters have a builtin brake system to stabilize the unit when in place. rotor of the wind turbine is locked in place to reduce the risk of injuries. Openings made in the wind turbine nacelle allow observation of the main internal components, i.e., the generator and controller. The bladed Wind Turbine Type Blade Radius Nacelle Length Dimensions (H x W x D) Direct drive, fixed-pitch three blade rotor 62.2 cm (24.5 in) 67.6 cm (26.6 in) 1800 x 991 x 991 mm (71.0 x 39.0 x 39.0 in) 21.8 kg (48 lb) Digital Multimeter (Optional) The Digital Multimeter consists of a BK Precision 2703C Tool Kit Digital Multimeter with Battery Test. It is ideal to perform voltage, current, and resistance measurements in exercises. 32 Festo Didactic
33 Voltage Ranges Current Range Resistance Range Dimensions (H x W x D) V ac / V dc 0-10 A dc 0-20 MΩ 165 x 78 x 42.5 mm (6.5 x 3.07 x 1.67 in) 285 g (0.63 lb) Multimeters Module (Optional) 8946-A0 The Multimeters Module, Model A, consists of three Digital Multimeters, Model , installed on the front panel of a half-size module. This allows the Multimeters Module to be inserted in a Workstation, just like any other module. Multimeters Quantity 3 Voltage Range Current Range Resistance Range Dimensions (H x W x D) Pyranometer (Optional) V dc and ac 0-10 A dc 0-20 MΩ 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in) TBE The Pyranometer is a high-quality instrument for measuring solar irradiance. The thermopile sensor construction measures the solar energy that is received from the total solar spectrum and the whole hemisphere (180 field of view). The output signal of the Pyranometer is a voltage proportional to the measured solar irradiance, expressed in Watts/ Festo Didactic 33
34 m². The Pyranometer is a useful instrument when measuring the performance of solar panels versus insolation. Spectral Range Sensitivity Response Time Maximum Solar Irradiance 310 to 2800 nm 5 to 20 uv/w/m² <18 s Field of View 180 Operating Temperature Range Dimensions (H x W x D) Personal Computer (Optional) W/m² -40 C to +80 C (-40 F to +176 F) 85 x 130 x 100 mm (3.4 x 5.1 x 3.9 in) 1.1 kg (2.4 lb) The Personal Computer consists of a desktop computer running under Windows 7. A monitor, keyboard, and mouse are included. Power Requirements Current Service Installation 1.05 A Standard single-phase ac outlet 34 Festo Didactic
35 Heavy-Duty Tripod (Optional) The Heavy-Duty Tripod is a compact, heavy-duty unit that is perfectly suited to hold the Solar Panel, Model 8806, when performing outdoor exercises. Load Capacity Closed Length Minimum Height Maximum Height 5 kg (11 lb) 53.5 cm (21.1 in) 8.0 cm (3.1 in) 146 cm (57.5 in) 1.8 kg (4 lb) Magnetic Field Strength Indicator (Optional) The Magnetic Field Strength Indicator displays the strength of the residual magnetism in a metallic object. It is enclosed in a rugged, pocket-sized enclosure and requires no power to operate. Festo Didactic 35
36 Wind Turbine Rotor (Optional) The Wind Turbine Rotor is the same rotor as that used in the generator of the Wind Turbine Generator/ Controller, Model , and the Wind Turbine Demonstrator, Model 8216-D. It enables observation of the rotor construction. It also allows observation of the arrangement of the permanent magnets on the rotor using the Magnetic Field Strength Indicator, Model Festo Didactic
37 Reflecting the commitment of Festo Didactic to high quality standards in product, design, development, production, installation, and service, our manufacturing and distribution facility has received the ISO 9001 certification. Festo Didactic reserves the right to make product improvements at any time and without notice and is not responsible for typographical errors. Festo Didactic recognizes all product names used herein as trademarks or registered trademarks of their respective holders. Festo Didactic Inc All rights reserved. Festo Didactic SE Rechbergstrasse Denkendorf Germany P. +49(0)711/ F. +49(0)711/ Festo Didactic Inc. 607 Industrial Way West Eatontown, NJ United States P F Festo Didactic Ltée/Ltd 675 rue du Carbone Québec QC G2N 2K7 Canada P F Festo Didactic 37
46120-F0 Solar Energy Training System
46120-F0 Solar Energy Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 3 Table of Contents of
Alternative and Renewable Energy Systems
Alternative and Renewable Energy Systems Known as the standard for technical training systems in use across virtually every industry and around the globe, Lab-Volt is now using its expertise to provide
Alternative and Renewable Energy Systems
Alternative and Renewable Energy Systems Known as the standard for technical training systems in use across virtually every industry and around the globe, Lab-Volt is now using its expertise to provide
3466 Building Energy Management Training Systems
3466 Building Energy Management Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2015 Table of Contents General Description 3 Courseware 3 Topic Coverage 4 List of Available
Renewable Energy. Solar Power. Courseware Sample 86352-F0
Renewable Energy Solar Power Courseware Sample 86352-F0 A RENEWABLE ENERGY SOLAR POWER Courseware Sample by the staff of Lab-Volt Ltd. Copyright 2009 Lab-Volt Ltd. All rights reserved. No part of this
Photovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
Permanent Magnet DC Motor
Electricity and New Energy Permanent Magnet DC Motor Courseware Sample 86357-F0 Order no.: 86357-10 Revision level: 12/2014 By the staff of Festo Didactic Festo Didactic Ltée/Ltd, Quebec, Canada 2011 Internet:
Three-Phase AC Power Circuits
Electricity and New Energy Three-Phase AC Power Circuits Student Manual 86360-F0 Order no.: 86360-00 Revision level: 10/2014 By the staff of Festo Didactic Festo Didactic Ltée/Ltd, Quebec, Canada 2010
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
High Power Programmable DC Power Supplies PVS Series
Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient
Charge Regulator SCR 12 Marine
Charge Regulator SCR 12 Marine Manual Many thanks for purchasing a superwind product. The SCR 12 Marine is a charge regulator of highest quality and will perfectly and reliably charge your batteries for
8086 Telephony Training Systems
8086 Telephony Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 01/2016 Table of Contents General Description 2 Topic Coverage 6 Features & Benefits 6 List of Available Training
C Standard AC Motors
C Standard AC Standard AC C-1 Overview, Product Series... C-2 Constant... C-9 C-21 C-113 Reversible C-147 Overview, Product Series Constant Reversible Electromagnetic Brake C-155 Electromagnetic Brake
21016 elearning Courses
21016 elearning Courses LabVolt Series Datasheet Festo Didactic en 03/2015 Table of Contents General Description 3 List of Available Training Systems 4 Equipment Description 5 2 Festo Didactic General
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
The quadrature signals and the index pulse are accessed through five 0.025 inch square pins located on 0.1 inch centers.
Quick Assembly Two and Three Channel Optical Encoders Technical Data HEDM-550x/560x HEDS-550x/554x HEDS-560x/564x Features Two Channel Quadrature Output with Optional Index Pulse Quick and Easy Assembly
Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.
Lab 9: Synchronous motor. Objective: to examine the design of a 3-phase synchronous motor; to learn how to connect it; to obtain its starting characteristic; to determine the full-load characteristic of
Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps
Solar Home System User Manual AEHSHS0110W2L Solar Home System 2 Lamps All rights reserved Specifications subject to change without prior notice 2 Dear Customer, Thank you for purchasing Schneider Electric
DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual
DMX-K-DRV Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Manual page 1 rev 1.33 COPYRIGHT 2007 ARCUS, ALL RIGHTS RESERVED First edition, June 2007 ARCUS TECHNOLOGY copyrights this document.
Installation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar
Installation Guide of Sunrise Solartech PV Modules Term 2013 Contents Purpose of this guide General Safety precaution for installing a solar Photovoltaic system Product Identification Mechanical Installation
TruPower-Portable-500W. Solar Starter kit
TruPower-Portable-500W Solar Starter kit This Solar starter kit is an easy to use solar power supply system that is the complete solution for all your solar power needs. It is a solar generator that converts
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
8022-0E Motor Winding Kit
8022-0E Motor Winding Kit LabVolt Series Datasheet Festo Didactic en 220 V - 60 Hz 06/2016 Table of Contents General Description 2 Optional Equipment Required to Operate the Rotating Machines 3 Features
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Single-Phase AC Synchronous Generator
ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual This 30Amp charge controller is designed to protect your 12Volt Lead-acid or Gel-cell battery from being overcharge by solar
Servo Info and Centering
Info and Centering A servo is a mechanical motorized device that can be instructed to move the output shaft attached to a servo wheel or arm to a specified position. Inside the servo box is a DC motor
User's Guide. True RMS Industrial Multimeter
User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
Absolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
Series 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
BB800 Off-Grid Solar System
BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry
Three Channel Optical Incremental Encoder Modules Technical Data
Three Channel Optical Incremental Encoder Modules Technical Data HEDS-9040 HEDS-9140 Features Two Channel Quadrature Output with Index Pulse Resolution Up to 2000 CPR Counts Per Revolution Low Cost Easy
What Is Regeneration?
What Is Regeneration? Braking / Regeneration Manual Regeneration Overview Revision 1.0 When the rotor of an induction motor turns slower than the speed set by the applied frequency, the motor is transforming
Analog Servo Drive 25A8
Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit
SYSTEM 4C. C R H Electronics Design
SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Unit 33 Three-Phase Motors
Unit 33 Three-Phase Motors Objectives: Discuss the operation of wound rotor motors. Discuss the operation of selsyn motors. Discuss the operation of synchronous motors. Determine the direction of rotation
Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE
Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and
PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
Current and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
WIND TURBINE TECHNOLOGY
Module 2.2-2 WIND TURBINE TECHNOLOGY Electrical System Gerhard J. Gerdes Workshop on Renewable Energies November 14-25, 2005 Nadi, Republic of the Fiji Islands Contents Module 2.2 Types of generator systems
Workspace and storage furnishings
LISTA Compact Workspace and storage furnishings Test and inspection workstations With its modular test and inspection workstations, LISTA offers optimised solutions for modern quality assurance practices.
SX460. Generator Automatic Voltage Regulator Operation Manual
SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
GT Sensors Precision Gear Tooth and Encoder Sensors
GT Sensors Precision Gear Tooth and Encoder Sensors NVE s GT Sensor products are based on a Low Hysteresis GMR sensor material and are designed for use in industrial speed applications where magnetic detection
BLOOD COLLECTION MIXER
USER S MANUAL BLOOD COLLECTION MIXER Model CM735 No. CAT.CM73522Ce Centron Technologies Corporation 319-25 Sadang-4-dong, Dongjak-ku Seoul, Korea 156-823 Tel. +82-2.522.7807 Fax +82-2.522.7806 Table of
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
Product Specification instalert Rapid Messenger Variable Message Sign
instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits
0.9V Boost Driver PR4403 for White LEDs in Solar Lamps
0.9 Boost Driver for White LEDs in Solar Lamps The is a single cell step-up converter for white LEDs operating from a single rechargeable cell of 1.2 supply voltage down to less than 0.9. An adjustable
Low and High Voltage Power Supplies
Low and High Voltage Power Supplies We work according to ISO 9001: 2008 Since 1994 Fug works according to the quality assurance system ISO 9001. All shipped units are checked and documented in our testing
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
LIFT CONTROL SYSTEMS CATALOGUE 2007
LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
Miniature High-Torque, DC Servomotors and DC Gearmotors
typical applications Robotics Factory automation Medical equipment Computer peripherals and office equipment Portable, battery-operated equipment Textile machinery Packaging machinery Actuators Miniature
Renewable Energy Monitor User Manual And Software Reference Guide. [email protected] (979) 703-1925
Renewable Energy Monitor User Manual And Software Reference Guide [email protected] (979) 703-1925 1 Introducing the Horizon Renewable Energy Monitor The Renewable Energy Monitor is an educational
Renewable Energy Test Station (RETS) TEST PROCEDURES FOR SOLAR TUKI
Renewable Energy Test Station (RETS) TEST PROCEDURES FOR SOLAR TUKI March 2007 A. Test Procedures for Solar Tuki Lamp S. No. Test Parameters Technical Requirements Instruments Required Test Methods A.
What are the basic electrical safety issues and remedies in solar photovoltaic installations?
What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
RACEAIR REMOTE PAGER SYSTEM
Computech Systems, Inc. 301-884-5712 30071 Business Center Dr. Charlotte Hall, MD 20622 RACEAIR REMOTE PAGER SYSTEM TM Introduction: Computech s RaceAir Remote Competition Weather Station with the Data
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
TOA 900 SERIES II MIXER POWER AMPLIFIER
Operating Instructions TOA 900 SERIES II MIXER POWER AMPLIFIER A-903MK2 A-906MK2 A-912MK2 TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING
User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1
User Manual Hybrid 1KW-5KW INVERTER / CHARGER Version: 1.1 Table of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Product Overview... 3 INSTALLATION...
D.C. Motors. Products and specifications subject to change without notice.
D.C. Motors Order/Technical Support - Tel: (8) 677-5 / FAX: (8) 677-865 / www.crouzet-usa.com / DC Motors Selection guide Gearbox Speed Torque max (Nm).5. Type of Gearbox 8 8 8. Power usable (w) Torque
www.curtisinstruments.com
CANBUS I/O EXPANSION MODULE MODELS 56 / 56P FEATURES Eighteen multi-purpose I/O pins provide simple, flexible vehicle control system expansion. Two high-frequency (A, A) PWM driver outputs support a variety
1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING
1115 4G SERIES GOVERNOR with 4-20 ma ANALOGUE & DIGITAL SPEED SETTING PO Box 28, 9300AA Roden, The Netherlands Tel: +31 505019888 Fax: +31 505013618 E-mail: [email protected] 1115 4G
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l
D C S e r v o S y s t e m s RH Mini Series Total Motion Control Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l Precision Gearing & Motion Control DC SERVO ACTUATORS
maxon sensor maxon sensor
Sensor Spindle drive Gearhead E Motor (BLD Motor) D Motor X Drives (configurable) Motor control obust encoders, D tachometers, and resolvers with high accuracy and high signal resolution. Due to resonance,
Agilent AEDB-9140 Series Three Channel Optical Incremental Encoder Modules with Codewheel, 100 CPR to 500 CPR Data Sheet
Agilent AEDB-9140 Series Three Channel Optical Incremental Encoder Modules with Codewheel, 100 CPR to 500 CPR Data Sheet Description The AEDB-9140 series are three channel optical incremental encoder modules
H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
LIFT CONTROL SYSTEMS CATALOGUE 2007
LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
Training Systems for Renewable Energies. Acquiring Practical Skills and Project-oriented Expertise
Training Systems for Renewable Energies Acquiring Practical Skills and Project-oriented Expertise Qualifications through Quality Inexhaustible, sustainable, real the future is green The move away from
Air damper actuators
4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically
Festo Didactic: LabVolt Series Training Systems A whole new range of possibilities
Festo Didactic: LabVolt Series Training Systems A whole new range of possibilities Sharing Your Commitment to Technical Education Origins of the LabVolt Series by Festo Didactic For the last 50 years,
ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
Contactless Power Transfer : Inductive charging of EV
Contactless Power Transfer : Inductive charging of EV 7-12-2010 P.Bauer Delft University of Technology Challenge the future EV have to be charged December 7, 2010 2 2 Chicken and egg problem December 7,
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
Digital Ground Resistance Tester. Models 4620 & 4630. Digital Ground Resistance Tester
Digital Ground Resistance Tester Models 4620 & 4630 Digital Ground Resistance Tester Models 4620 and 4630 perform both ground resistance and soil resistivity tests. These testers measure from 0 to 2000Ω,
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
Description. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5
AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC
FRENIC5000MS5 for Machine Tool Spindle Drives
FRENIC5MS5 for Machine Tool Spindle Drives Yoshikazu Tanaka Hiroaki Hayashi Hiroshi Takahashi 1. Introduction Fig.1 External view of FRENIC5MS5 In AC spindle drive systems for machine tools, operation