Network Power Distribution Module. Installation and Programming Manual
|
|
|
- Augustine Jenkins
- 10 years ago
- Views:
Transcription
1 Network Power Distribution Module Installation and Programming Manual LINQ8PD - Network Power Distribution Module - Eight (8) Fused Outputs LINQ8PDCB - Network Power Distribution Module - Eight (8) PTC Outputs DOC#: LINQ8PD Rev More than just power.
2 Overview: ltronix LINQ8PD(CB) network power distribution module facilitates monitoring, reporting and control of one (1) or two (2) low voltage C or supervised DC power supply/chargers over the network. Reports diagnostics via /SNMP notifications greatly reducing system downtime and eliminating unnecessary service calls. LINQ8PD(CB) retrofits with most currently installed multi-output power supply/chargers. Specifications: Input Power: Input1/Input2: 12.5 amp each or 12.5 amp each te: Do connect C and DC simultaneously to INP1 and INP2 Outputs: Eight (8) fused or PTC protected outputs: - LINQ8PD: Blade fuses are rated amps - LINQ8PDCB: PTCs are rated 2.5 amps Power output(s) can be locally or remotely controlled Surge Suppression Status Monitoring: Power Supply(ies) output voltage and load Voltage and load of each output FCP trigger and reset status Unit temperature (Celsius) Power Supply C and Battery status Battery health Programming Features: Power Supply(ies) voltage and load limits (High/Low) FCP trigger type (wet or dry-n.o./n.c.) Input Function (FCP reset/tamper) Output Reset Trigger (N.O./N.C.) Battery Monitor Configuration: - Capacity - Charge Level - Max. Charge and Discharge Current - Service Date Configurable Output Relay(s) Individual Output Configuration: - Device ID - Voltage and Current Limits (High/Low) - FCP Trigger Setting (latching/non-latching/inactive) - Battery Backup Network Security: Secure Socket Layer (SSL) Reporting: SNMP trap messages. notifications Event Log tracks history Fire larm Interface: Supervised FCP disconnect ( or n-) FCP reset (N.C. or N.O.) Mechanical: Board Dimensions: 5.5 L x.625 W x.96 H (19.7mm x 92.7mm x 24.8mm) Product weight (approx.):.4 lbs. (.18kg) Shipping weight (approx.):.7 lbs. (.2kg) LINQ8PD - Fig. 1 Terminal/Connector Identification: B C D E F G GND GND RET -- FCP IN -- FCP RLY 2 RESET FCP EOL RET+ FCP IN+ FCP RLY 1 BT LOCL H U T ~ -- INP1 + ~ ~ -- INP2 + ~ <INP1 OFF INP2> UPLINK DOWNLINK LINQ8PD ltronix Corp. Brooklyn, NY 1122 BT C FCP I J S + BT IN - R + BT OUT - Fuse Battery FUSE OUT1 FUSE OUT2 FUSE OUT 15 FUSE OUT4 FUSE OUT5 FUSE OUT6 FUSE OUT7 FUSE OUT8 K Q P BT C NO C NO C DRY Inputs OUT OUT OUT + -- OUT OUT OUT OUT OUT8 + C Fail NC C NC C Battery Fail L O N M LINQ8PD/LINQ8PDCB
3 Terminal/Connector Identification: Terminal/Legend GND, B C RESET D E F G H FCP I J reset. K L M N O P Q R S T U B CGND, D FCP E F EOL G H I Connects J K L to MEOL N Oor next P QLINQ8PD(CB). R S T U B C D+ RET E F-- G H I J FCP K L EOL, M N or ext P LINQ8PD(CB). Q R S T U B C D FCP E F -- GIN H+ I J K Wet L Minput N from O P FCP Q R+. S T U C D E FCP F G RLY H I 1, J2 K L MFCP N reporting O P Q relay. R S T U D E F Downlink G H I J K L M NConnection O P Qto Rpower S Tsupply U or second LINQ8PD(CB) module. E F G HUplink I J K L M N OConnects P Q to R next S TLINQ8PD(CB) U upstream from this module. If this is the first LINQ8PD(CB) in the daisy chain this connector is not used. F G H BT I J Local K LLED M N O PIndicates Q R battery(ies) S T U thresholds. G H I FCP/C/BT J K L M N LEDs O P QIndicates R S status T U of FCP, C and Battery. H I J KHeartbeat L M LED N O P Q RIndicates S T the U LINQ8PD(CB) is operational. I J K RJ45 L M N O P Q R SEthernet: T U LN or laptop connection enables LINQ8PD(CB) programming and status monitoring. J K L MUSBN O P Q R S TLaptop U connection enables LINQ8PD(CB) initial setup and programming. K L M Battery Fail Indicates low battery condition, e.g. connect to alarm panel. Relay normally energized when DC power is present. N O P Q R S T U NC, C, NO Contact rating 1 VDC. L M C Fail Indicates loss of C power, e.g. connect to audible device or alarm panel. Relay normally energized N O P Q R S T U NC, C, NO when C power is present. Contact rating 1 VDC (power-limited). M N O + OUT1 -- to P Q R S T + OUT8 -- U 24VC/28VC or 12VDC/24VDC continuous output. N O P QC R/ NO, S CT U Connection to [C Fail] terminals on power supply. O P Q RBT S / TNO, UC Connection to [BT Fail] terminals on power supply. P Q R + S BT T UOUT -- Connection to stand-by batteries. Q R S + T BT U IN -- Connection to [+ BT -- ] terminals on power supply. R S T U-- INP2 + Second C or DC power supply input. te: Do connect C and DC simultaneously to INP1 and INP2. S T U -- INP1 + First C or DC power supply input. te: Do connect C and DC simultaneously to INP1 and INP2. LED Diagnostics: LED Flash Codes BT LOCL ON Charge/Discharge current working properly Blinking Charge/Discharge current on the battery exceed limits FCP ON FCP triggered OFF FCP released C ON Input signal active OFF Input signal inactive BT ON Input signal active OFF Input signal inactive ON Output is ON and working properly OUT1-OUT8 OFF Output is OFF Blinking Output is ON and voltage and/or current exceeds limits LINQ8PD/LINQ8PDCB - -
4 Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFP 7/NFP 72/NSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only and should be installed by qualified personnel. 1. Disconnect the C mains and batteries (if used) from the power supply(ies) before connecting the LINQ8PD(CB) 2. Mount LINQ8PD(CB) into position and secure with mounting screws. Interconnecting two (2) LINQ8PD(CB) modules: Two (2) LINQ8PD(CB)s can be interconnected to enable both units to be accessed from a single IP address. Connect interface cable (supplied) to the interface port marked [DOWNLINK] of first LINQ8PD(CB) which will be the master to interface port marked [UPLINK] of second LINQ8PD(CB).. Power Supply Input Connection: The LINQ8PD(CB) can be connected to two independent C or DC power supplies that can be routed thru each of the individual outputs. Each output is equipped with an input selection switch which is used to route the desired input to the output. This switch also has a center off position that can be used to turn power off to an output. (a) Single Power Supply Input: Connect the output of the power supply to the terminals marked [+INP1-] and set the Input selection switch for each output to the [INP1] position. (b) Dual Power Supply Inputs: When the use of two independent power supplies is desired connect one power supply to the terminals marked [+INP1-] and the second power supply to the terminals marked [+INP2-]. Set the Input selection switch for each output to the appropriate position. Reconnect the C mains of the connected power supply(ies) and verify the voltage of each of the eight outputs. This helps avoid potential damage. Disconnect the C mains of the connected power supply(ies). te: Do connect C and DC simultaneously to INP1 and INP2. 4. Output Connections: Connect devices to be powered to the terminals marked [-OUT1+ to -OUT8+] on LINQ8PD(CB) carefully observing polarity. When two power supplies are connected to the LINQ8PD(CB) verify that the output voltage matches the operating voltage of the connected devices. 5. Battery Connections: Skip this step when connecting C power supplies or DC power supply(ies) without batteries. Connect the power supplies battery charging circuit to the terminals marked [+BT IN-], connect the battery leads to the terminals marked [+BT OUT-]. te: Do not connect battery(ies) until all connections have been made. For 24VDC operation connect two 12VDC batteries in series using the supplied yellow battery jumper. For ccess Control applications batteries are optional. When batteries are not used, a loss of C will result in the loss of output voltage. When the use of stand-by batteries is desired, they must be lead acid or gel type. 6. Battery and C Supervision Connections: Skip this step when connecting C power supplies These connections are required to monitor C and Battery Trouble conditions. These conditions cannot be monitored when connected to a non-supervised power supply. Connect the common (C) and normally open (N.O.) contact of the power supplies C and Battery supervision relay to the corresponding DRY Inputs of the LINQ8PD(CB). If required to connect supervisory trouble reporting devices to outputs marked [C FIL, BT FIL] supervisory relay outputs marked [NC and C] to appropriate notification devices. Use 22 WG to 18 WG for supervision reporting. 7. Fire larm Interface options: (not evaluated by UL) The Fire larm Interface and Reset options are programmable via the web interface. FI input trigger options: supervised normally closed [NC], normally open [NO], polarity reversal input from signaling circuit or wet input will trigger selected outputs. (a) rmally Open [NO] input: Connect the supplied 2.2k resistor (supplied) in parallel with the normally open trigger circuit to the terminals marked [GND, FCP EOL]. (b) rmally Closed [NC] input: Connect the supplied 2.2k resistor (supplied) in series with the normally closed trigger circuit to the terminals marked [GND, FCP EOL]. (c) Signaling Circuit/Wet input trigger: Connect the positive (+) and negative (-) of the signaling circuit/wet input trigger to the terminals marked [FCP IN + and [FCP IN -]. (d) Fire larm Reset: If a output is programmed to latch with manual reset connect either a normally open (N.O.) or normally closed (N.C.) dry input to the terminals marked [RESET & GND] 8. Reconnect C power mains to the connected power supply(ies) and connect back-up batteries LINQ8PD/LINQ8PDCB
5 Establishing Network Connection: Network Setup - ltronix Dashboard USB Connection The USB connection on the LINQ8PD(CB) is used for Network and Trap Receiver configuration only. When connected to a PC via the USB cable the LINQ8PD(CB) will receive power from the USB port allowing programming of the LINQ8PD(CB) prior to being connected to the power supply. 1. Install the software supplied with the LINQ8PD(CB) on the PC being used for programming. This software should be installed on all computers that will have access to the LINQ8PD(CB). 2. Connect the supplied USB cable to the USB port on the LINQ8PD(CB) and the computer.. Click [Dashboard Icon] on the desktop of the computer and open the Dashboard. 4. Click [USB Network Setup] button located in the upper right hand side of the Dashboard. This will open the USB Network Setup screen. In this screen the MC ddress of the LINQ8PD(CB) module will be found along with the Network Settings, Trap Receiver Settings and SNMP Port Settings. 1. Network Settings (Fig. 2a, pg. 5): In the IP ddress Method field select the method that the IP ddress for the LINQ8PD will be obtained Static or DHCP then follow the appropriate steps. STTIC: Field Name Enter the IP address assigned to the LINQ8PD(CB) by the IP ddress network administrator. Subnet Mask Enter the Subnet of the network. Enter the TCP/IP gateway of the network access point (router) being used Gateway te: Gateway configuration is required to properly receive s from the device. Enables standard remote access and monitoring. Enter the port HTTP Port number assigned to the LINQ8PD(CB) module by the network administrator. Default Port setting 8.* Enables secure remote access and monitoring. Enter the port number assigned to the LINQ8PD(CB) module by the network adminis- HTTPS Port trator. Default Port setting 44.* Used to update device firmware. Enter the port number System Port assigned to the LINQ8PD(CB) module by the network administrator. Default Port setting 667* a. Click [Submit Network Settings] button, a dialog box will display New network settings will take effect after the server is rebooted click OK. *te: When remote access is required or using multiple devices on the same network it is recommended to assign an independent port to each connected device. Fig. 2 Dashboard - USB Network Setup Linq8 MC ddress BC:4:::1:77 Network Settings: IP ddress Method: IP ddress: Subnet Mask: Gateway: HTTP Port: HTTPS Port: System Port: Submit Network Settings Restore Factory Settings Reboot Server STTIC D Trap Receiver Settings: SNMP Port Settings : x USB Network Settings Trap Receiver 1 : Trap Receiver 2 : Trap Receiver : Trap Receiver 4 : Trap Receiver 5 : Submit Trap Receiver IP Settings SNMP Port : 161 Trap Messages Port : 162 Submit Port Settings B C DHCP (Fig. 2a, pg. 5): Connect LINQ8PD(CB) to the DHCP router to obtain IP address. a. fter selecting DHCP in the IP ddress Method field click [Submit Network Settings] button, a dialog box will display New network settings will take effect after the server is rebooted click OK. Next click [Reboot Server] button (Fig. 2d, pg. 5). fter the LINQ8PD(CB) reboots the IP address assigned will appear in the IP ddress field. It is recommended to have the assigned IP ddress reserved on the router to ensure continued access to the LINQ8PD(CB) (see the network administrator). LINQ8PD/LINQ8PDCB - 5 -
6 Field Name Subnet Mask When operating in DHCP the router will assign the subnet mask values. Gateway Enter the TCP/IP gateway of the network access point (router) being used. HTTP Port Enables standard remote access and monitoring. Enter the port number assigned to the LINQ8PD(CB) module by the network administrator. Default Port setting 8.* HTTPS Port Enables secure remote access and monitoring. Enter the port number assigned to the LINQ8PD(CB) module by the network administrator. Default Port setting 44.* System Port Used to update device firmware. Enter the port number assigned to the LINQ8PD(CB) module by the network administrator. Default Port setting 667* b. Click [Submit Network Settings] button, a dialog box will display New network settings will take effect after the server is rebooted click OK. *te: When remote access is required or using multiple devices on the same network it is recommended to assign an independent port to each connected device. 2. Trap Receiver Settings (Fig. 2b, pg. 5): a. Enter up to five SNMP trap receiver IP addresses. When accessing the LINQ8PD(CB) remotely, check with the network administrator for proper configuration. b. Click [Submit Trap Receiver IP Settings] button, a dialog box will display New Trap Receiver IP settings will take effect after the server is rebooted click OK.. SNMP Port Settings (Fig. 2c, pg. 5): SNMP uses the default port 161 for general SNMP messages and port 162 for SNMP trap messages. In the event these ports need to be changed, enter the new port numbers assigned by the network administrator. a. Click [Submit Port Settings] button, a dialog box will display New Port settings will take effect after the server is rebooted click OK. b. fter all information has been entered, Click [Reboot Server] button (Fig. 2d, pg. 5), a dialog box will display Please allow up to sec for the server to reboot, click OK. c. fter the LINQ8PD(CB) has been rebooted all programmed information will be saved. d. Disconnect the USB cable from the LINQ8PD(CB) module. If the LINQ8PD(CB) has not been connected to the power supply(ies) being monitored, (refer to Installing LINQ8PD Board on pg. 2). e. Connect one end of the network cable to the network jack on the LINQ8PD(CB) and the other to the network connection or the PC to be used for programming. te: notification must be setup via the Browser, Ref to Settings in the Browser Setup section of this manual. Browser Setup When not using the ltronix Dashboard USB connection for the initial Network setup, the LINQ8PD(CB) needs to be connected to the power supply(ies) being monitored (refer to Installing LINQ8PD Board on page??) prior to programming. Factory Default settings: IP ddress: User Name: admin Password: admin 1. Set the static IP address for the laptop to be used for programming to the same network IP address as the LINQ8PD(CB) i.e (default address of the LINQ8PD(CB) is ). 2. Connect one end of the network cable to the network jack on the LINQ8PD(CB) and the other to the network connection of the laptop.. Open a browser on the computer and enter into the address bar. dialog box uthentication Required will appear requesting both user name and password enter the default values here. 4. Click [Log In] button. The status page of the LINQ8PD(CB) will appear. This page displays the real time status and health of each power supply connected to the LINQ8PD(CB) LINQ8PD/LINQ8PDCB
7 1. Network setup: Click [Network Settings] tab. This will open the Network Setting screen. In this screen the MC ddress of the LINQ8PD(CB) module will be found along with the programming fields for the Network Settings, Trap Receiver Settings, SNMP Port Settings and Settings. Network Settings (Fig. a, pg. 7): In the IP ddress Method field select the method that the IP ddress for the LINQ8PD(CB) will be obtained Static or DHCP then follow the appropriate steps. Fig. Status Network Settings Site ID: LINQ8 Network Settings: Setup Network Settings IP ddress Method: STTIC Device Management Interface Security Settings Events Log Settings: Help Monday, Sept [2: pm] D From: event.report@linqinfo STTIC (Fig. a, pg. 7): Field Name IP ddress Enter the IP address assigned to the LINQ8PD(CB) by the network administrator. Subnet Mask Enter the Subnet of the network. Enter the TCP/IP gateway of the network access point (router) being used Gateway te: Gateway configuration is required to properly receive s from the device. Enter the HTTP port number assigned to the LINQ8PD(CB) module by the network administrator to allow remote access and monitoring. HTTP Port The default inbound port setting is 8. HTTP is not encrypted and unsecure. Even though HTTP can be used for remote access it is recommended primarily for use with LN connections. Enter the HTTPS port number assigned to the LINQ8PD module by the network administrator to allow remote access and monitoring. HTTPS Port The default inbound port setting is 44. Being encrypted and more secure HTTPS is highly recommended for remote access. Used to update device firmware. Enter the port number assigned to the System Port LINQ8PD(CB) module by the network administrator. Default Port setting 667* a. Click [Submit Network Settings] button, a dialog box will display New network settings will take effect after the server is rebooted click OK. Trap Receiver Settings: IP ddress: Subnet Mask: Gateway: HTTP Port: 8 HTTPS Port: 44 System Port: 667 MC ddress: BC:4:::1:72 Submit Network Settings Trap Receiver IP ddress 1: Trap Receiver IP ddress 2: Trap Receiver IP ddress : Trap Receiver IP ddress 4: Trap Receiver IP ddress 5: Submit Trap Receiver IP Settings SNMP Port Settings: SNMP Port: 161 Trap Message Port: 162 Submit Port Settings B C Subject: Username: event.report Password: SMTP server IP: smtp.gmail.com SMTP server Port: 587 Outgoing ddress 1: Outgoing ddress 2: Outgoing ddress : Outgoing ddress 4: Outgoing ddress 5: Submit Test Submit Settings Restore Factory Settings Reboot Server E DHCP (Fig. a, pg. 7): fter selecting DHCP in the IP ddress Method field click [Submit Network Settings] button, a dialog box will display New network settings will take effect after the server is rebooted click OK. Next click [Reboot Server] button. fter rebooting the LINQ8PD(CB) will be set in the DHCP mode. The IP address will be assigned by the router when the LINQ8PD(CB) is connected to the network. It is recommended to have the assigned IP ddress reserved to ensure continued access (see the network administrator). Field Name Subnet Mask When operating in DHCP the router will assign the subnet mask values. Gateway TCP/IP gateway of the network access point (router) being used will be displayed. Enter the HTTP port number assigned to the LINQ8PD(CB) module by the network administrator to allow remote access and monitoring. The default inbound HTTP Port port setting is 8. HTTP is not encrypted and unsecure. Even though HTTP can be used for remote access it is recommended primarily for use with LN connections. Enter the HTTPS port number assigned to the LINQ8PD(CB) module by the network administrator to allow remote access and monitoring. HTTPS Port The default inbound port setting is 44. Being encrypted and more secure HTTPS is highly recommended for remote access. Click the [Submit Network Settings] button, a dialog box will display New network settings will take effect after the server is rebooted click OK. LINQ8PD/LINQ8PDCB - 7 -
8 Trap Receiver Settings (Fig. b, pg. 7): a. Enter up to five SNMP trap receiver IP addresses. When accessing the LINQ8PD(CB) remotely check with the network administrator for proper configuration. b. Click [Submit Trap Receiver IP Settings] button, a dialog box will display New Trap Receiver IP settings will take effect after the server is rebooted click OK. SNMP Port Settings (Fig. c, pg. 7): SNMP uses the default port 161 for general SNMP messages and port 162 for SNMP trap messages. In the event these port need to be changed enter the new port numbers assigned by the network administrator. Click [Submit Port Settings] button, a dialog box will display New SMNP port settings will take effect after the server is rebooted click OK. Settings (Fig. d, pg. 7): The LINQ8PD(CB) can send s via an in-house server, service provider (i.e. Gmail, Yahoo) or ltronix default service. In-house server: Field Name From Enter the address assigned to the LINQ8PD(CB) module by the system administrator. Subject Identify the location of the v (i.e. the Site ID). Username Enter the username associated with the LINQ8PD(CB) module address. Password Enter the username password. SMTP server IP Enter the SMTP IP address of the in-house server. SMTP server Port Enter the SMTP port assigned to the in-house server. Outgoing ddress 1-5 Enter up to five outgoing addresses. a. Click [Submit Settings] button and the settings will be saved. service provider: Field Name From Enter the address for the LINQ8PD(CB) module. Subject Identify the location of the LINQ8PD(CB) (i.e. the Site ID). Username Enter the username associated with the LINQ8PD(CB) module address. Password Enter the username password. SMTP server IP Enter the SMTP IP address of the service provider. SMTP server Port Enter the SMTP port number. The default SMTP ports are 25 or 465 unless otherwise specified. Outgoing ddress 1-5 Enter up to five outgoing addresses. a. Click [Submit Settings] button and the settings will be saved. ltronix default service: a. ll required sender and network fields have already been populated. b. Outgoing ddress 1-5: Enter up to five outgoing addresses. c. Click [Submit Settings] button to save the settings. d. Test the setup by clicking [Test ] button. e. n will be sent to all Outgoing addresses. If the test is not received contact the network administrator and repeat the setup steps. f. fter all fields have been programed, click [Reboot Server] button, a dialog box will display Please allow up to sec. for server to reboot click OK. ll programmed information will be saved after the server has rebooted LINQ8PD/LINQ8PDCB
9 2. Setup (Fig. 4, pg. 9): te: If the ltronix Dashboard is being used for LINQ8PD(CB) setup, refer to the Folder and Device configuration section in the ltronix Dashboard setup/user manual. Click on [Setup] tab. The LINQ8PD(CB) setup page will open. This page is used to configure all operating functions of the LINQ8PD(CB). PS1 Volts Low Limit 4 V PS2 Volts Low Limit 1.1 V Input Function Reset Bat Charge Level 9 % Output Relay 1 Field Name PS1 mps High Limit PS2 mps High Limit 5 Output Reset Trigger N.C. Max Battery 2.75 Output Relay 2 Tamper Discharge Current Enter a descriptive name that will identify the location PS1 mps (building, Low Limit company PS2 mps Low Limit or campus) Max Temp where the 5 LINQ8PD(CB) C Max Charge Current installed..9 Output Relay FCP Site B CID D E F G H I J K L M N O P Q R S T U The Site ID will appear in both the trap message and notifications. Status Setup 1 B Date/Time C D E F G H I Clicking J K Lon [Sync M NDate/Time O P Qwith R Computer], S T U will set the LINQ8PD(CB) to the time of the host computer. 2 n- B C LINQ8PD(CB) D E F G ID H I J Enter K La descriptive M N O name P Qand/or R location S T Uof the LINQ8PD(CB). Setup Inactive B C D PS2 E Presence F G H I J 4 K From L Mthe Npull Odown P menu Q Rselect S T Uto disable PS2 if only one power supply is connected. Site ID: Enter Location B C D E 5 n- Battery F G Presence H I J K L From M Nthe Opull Pdown Q menu R S select T U if batteries are not 6 connected. If batteries are not connected skip this section. Inactive 8 n- PS1/PS2 mps/voltage Limits (Fig. 5, pg. 9): Fig. Enter 5 ID Submit Settings Field Name PS1 Volts High Limit Enter both the Voltage Limit High and Voltage Limit Low for the connected power supplies. If either of these PS1/PS2 Voltage Limit PS1 Volts Low Limit 4 limits are exceeded an SNMP trap message and/or notification will be generated. PS1 mps High Limit Enter both the mp Limit High and mp Limit Low for the connected power supplies. If either of these limits PS1/PS2 mp Limit are exceeded an SNMP trap message and/or notification will be generated. PS1 mps Low Limit Status Setup Network Settings Security Settings Events Log FCP Trigger (Fig. 6, pg. 9): From the pull down menu select either Wet or Dry. Select Site ID: Enter Location Update Site ID Wet Trigger Input voltage from the fire alarm signal circuit will disconnect all outputs programmed for FCP disconnect. Dry Trigger short or open on the supervised FCP input will disconnect all outputs programmed for FCP disconnect. C Update PS2 Presence Fig. 6 Input Function (Fig. 6, pg. 9): From the pull down menu select either Reset or Tamper. Select Reset Tamper PS1 Volts Low Limit When using the FCP Interface with outputs set in latching mode the reset trigger input PS1 mps High Limit is designated as the FCP manual release. When the outputs are set in non-latching mode or the FCP interface is PS1 not mps being Low Limit used the reset trigger input. Output Reset Trigger (Fig. 6, pg. 9): From the pull down menu select either N.O. or N.C. Select N.O. N.C. rmally Open reset Trigger Input. rmally Closed Trigger input. Fig. Status 4 Setup Site ID: Enter Location Device Management Interface Max Temp: The LINQ8PD(CB) will measure the ambient temperature of the enclosure it is mounted in. Entering a high temperature limit in Celsius, if this limit is exceeded an SNMP trap message and/or notification will be generated. 7 PS1 Volts High Limit LINQ8PD/LINQ8PDCB Submit Settings Update Site ID Update PS2 Presence Battery Presence V PS2 Volts High Limit 14 V FCP Trigger Dry Bat Capacity Monday, Sept [2: pm] Minimize Sync with computer Minimize Others Output Device ID Current High () Current Low () Voltage High (V) Voltage Low (V) FCP Trigger Battery Backup Output Status 7 Setup C Setup Network Settings PS1 Volts High Limit 4 Security Settings D Events Log Help E 7 H Battery Service Date 2 /2 / 215 Com Trouble B Update PS2 mps PS2 mps Help D V PS2 Volts H V PS2 Volts L Output Device ID Curren 1 2 C Network Se Device Management Interf V PS2 Volts High Limit 14 V PS2 Volts Low Limit 1.1 PS2 mps High Limit PS2 mps Low Limit 5 Output Device ID Current High () Current Low () Voltage High (V) Voltage Low (V) D Battery Presence E 5 V V FCP Trigger 6 Input Function 7 Dry Reset Bat Capaci Bat Charge Output Reset Max Batter 8 Trigger N.C. Discharge Max Temp 5 C Max Charg
10 Battery Monitor Configuration (Fig. 7, pg. 1): The LINQ8PD(CB) displays the real time battery health. Select Battery Capacity Enter the battery rating in amp hours. Battery Charge Level Enter the estimated percentage charge level of the Battery at the time of installation. Max. Battery Discharge Current Enter the high current limit to be drawn from the battery in the event of a power failure. If this limit is exceeded an SNMP trap message and/or notification will be generated. Enter the maximum charge current of the connected power supply. If this limit is exceeded an SNMP trap message and/or Max. Charge Current notification will be generated. Enter the date on which the installed Device batteries need to Management be serviced. n SNMP trap message Interface and/or notification will be generated on the entered date. Battery Service Date te: Batteries should be inspected at least once a year. Even though the expected battery life is 5 years, Device Management Interface it is recommended changing batteries in 4 years. Status Setup Network Settings Security Settings Events Log Help Output Relay configuration (Fig. 7, pg. 1): Three Status () output relays Setupof the Setup LINQ8PD(CB) Network Settings can be configured Security for Settings various uses. Events From the Log pull down Help menu select the desired setting for each relay. Site ID: Enter Location Update Site ID Monday, Sept [2: pm] Sync with computer Setup Output Relay 1: Setting Minimize Minimize Others Site C ID: Enter LocationThe relay will energize when Update C Site trouble ID is detected. Monday, Sept [2: pm] Sync with computer Com Trouble The relay will energize when Con Update all trouble conditions. PS2 Presence D Battery Presence Fig. E7 PS1 Volts High Limit V PS2 Volts High Limit 14 V FCP Trigger Dry Bat Capacity 7 H Battery Minimize Service Date Minimize Others 2 /2 / 215 Output Relay 2: PS1 Volts Low Limit 4 V PS2 Volts Low Limit 1.1 V Input Function Reset Bat Charge Level 9 % Output Relay 1 Com Trouble Enter Battery ID The Crelay Update will energize when PS2 Presence Battery trouble is Ddetected. Battery Presence E Tamper The PS1 relay mps will High energize Limit when the PS2 tamper mps High input Limit is triggered. 5 Output Reset Trigger N.C. Max Battery 2.75 Output Relay 2 Tamper Discharge Current PS1 Volts High Limit V PS2 Volts High Limit 14 V FCP Trigger Dry Bat Capacity 7 H Battery Service Date 2 /2 / 215 PS1 mps Low Limit PS2 mps Low Limit Max Temp 5 C Max Charge Current.9 Output Relay FCP Output Relay PS1 Volts Low Limit 4 V PS2 Volts Low Limit 1.1 V Input Function Reset Bat Charge Level 9 % Output Relay 1 Com Trouble FCP The relay Outputwill energize Device when ID the FCP Current input High () is triggered. Current Low () Voltage High (V) Voltage Low (V) FCP Trigger Battery Backup Output Status PS1 Tamper mps High Limit The relay 1 PS2 will Enter mps energize ID High when Limit the 5 tamper input Output is triggered. Reset Trigger N.C. Max Battery 2.75 Output Relay 2 Tamper Discharge Current 2 n- PS1 mps Low Limit PS2 mps Low Limit Max Temp 5 C Max Charge Current.9 Output Relay FCP Fig. 8 Inactive Output Device ID 4 Enter Current ID High () Current Low () Voltage High (V) Voltage Low (V) FCP Trigger Battery Backup Output Status 1 2 Output Configuration (Fig. 8, 7pg. 1): 4Field Name Device ID 5 Current High/Low 6 7 Voltage High/Low n- n- Inactive Enter a descriptive name for the device connected to the output. Submit Settings n- Enter both the high current limit and low current limit in the appropriate fields for the connected Device. If either of these limits are exceeded an SNMP trap message and/or notification will be Inactive generated. Enter both the high voltage limit and low voltage limit in the appropriate fields for the connected Device. If either of these limits are exceeded an SNMP trap message and/or notification will be generated. Inactive n- n- B B Submit Settings LINQ8PD/LINQ8PDCB
11 FCP Trigger (Fig. 8, pg. 1): From the pull down menu select how the output will operate when the FCP input is triggered. FCP Trigger Setting Inactive n Function/ The selected output will not switch when the FCP input is triggered. The selected output will switch when the FCP input is triggered and reset when the FCP trigger input is returns to a non-triggered state. The selected output will switch to a latched position when the FCP input is triggered. The selected output will remain latched until the Output Reset is triggered. Battery Backup (Fig. 8, pg. 1): From the pull down menu select if the output will remain ON in the event of a power failure. Select if the output will turn OFF in the event of a power failure. Output Status (Fig. 8, pg. 1): Output Status indicates if the output is (powered) or (not powered). The output can be turned on or off the clicking [/] button. fter all fields have been programmed, click on [Submit Setting] button, a dialog box will display, New Setting Submitted click OK. ll programmed information in now saved.. Security Settings (Fig. 9, pg. 11): Click on [Security Settings] tab. The LINQ8PD(CB) security setting page will open. This section is used to enable/disable Secure Socket Layer (SSL) and to change Username and Password. SSL will encrypt all the communication Fig. 9 with a secure key. n SSL certificate could be self-signed or obtained from a third party certification company. Device Management Interface SSL Certificate Setting (Fig. 9a, pg. 11): Generating a self-signed SSL Certificate and Key. Field Name State Two letter code representing the state where the organization is located. Location The city where the organization is located. The legal name of the organization. Organization This should not be abbreviated, and should include suffixes such as Inc., Corp, or LLC. Unit Name Name of the device. Common Name Domain name or IP address of the server. This is typically assigned by the network administrator. ddress n address used to contact the organization. Status Setup Network Settings Security Settings eflow Site ID: LINQ8 SSL Certificate Settings: State: Locality: Organization: Unit Name: Common Name: ddress: Submit SSL Settings Events Log Help Security Settings Monday, Sept [2: pm] SSL Status: Certificate Status: Cert Key Status: Key SSL State: Turn SSL Change Username and Password: Username: Password: Confirm Password: Save Username and Password B C fter all fields have been completed click [Submit SSL Settings] button, a dialog box will appear Please allow up to sec for server to reboot click OK. self-signed SSL certificate will be generated with the information provided in the SSL certificate settings fields. The certificate will be valid for 5 days, and time stamped with the time settings present on the LINQ8PD(CB) module. The date and time must be synced with the host computer before generating an SSL certificate. Using a private SSL certificate and Key: Private SSL Certificates and Keys must be uploaded using the ltronix Dashboard. For additional information refer to the ltronix Dashboard setup/user manual section Updating firmware / SSL certificate and Key. LINQ8PD/LINQ8PDCB
12 SSL Status: Certificate Status (Fig. 9b, pg. 11): Key Status (Fig. 9b, pg. 11): Message s Message s Certificate OK Valid SSL Certificate. Key OK Valid SSL Key. Bad Certificate Invalid SSL Certificate. Bad Key Invalid SSL Key. Certificate Valid SSL Certificate has not been loaded. Key valid SSL Key has not been loaded. SSL State: The SSL of the LINQ8PD(CB) can be turned on and off by clicking [Turning SSL /Turning SSL ] button. Change Username and Password: Field Name Username Enter the new Username (up to 2 characters) required to access the LINQ8PD(CB). Password Enter the new Password (up to 2 alpha numeric characters) required to access the LINQ8PD(CB). Confirm Password Re-enter the new Password. Click [Save Username and Password] button, a dialog box with appear, New settings have been applied click OK. fter saving, the new username and password will be active. 4. Event Log and Heartbeat Timer (Fig. 1, pg. 12): Click [Event Log] tab. The LINQ8PD(CB) event log will open. This screen will display the event log along with the heartbeat timer setup. Event Log: The event log will display the 5 most recent events. To update the Event Log click [Display/Refresh Log] button, the most recent events will be displayed. Fig. 1 Status Event Log Site ID: LINQ8 Setup Display/Refresh Log Heartbeat Timer Settings: Network Settings Heartbeat Timer Settings Device Management Interface Security Settings 1 Days Hours Minutes Seconds Submit Events Log Help v Monday, Sept [2: pm] Last updated: Heartbeat Timer: The heartbeat timer will send a trap message indicating that the LINQ8PD(CB) is still connected and communicating. 5. Setting the Heart Beat Timer: a. Click the button labeled Heartbeat Timer Setting. b. Select the desired time between heartbeat messaging in the Days, Hours, Minutes and Seconds in corresponding fields. c. Click the button labeled Submit to save setting. 6. Updating Firmware: Firmware updates must be done using the ltronix Dashboard. For additional information refer to the Updating firmware / SSL certificate and Key section in the ltronix Dashboard setup/user manual LINQ8PD/LINQ8PDCB
13 Fig. 11 Device Management Interface Status Setup Network Settings Status Site ID: LINQ8 LINQ8PD ID: LINQ8 DEV PS1 Output Voltage 27.5 VDC PS1 Load 2.55 PS2 Output Voltage PS2 Load E 1.7 VDC 2.55 Security Settings FCP Status Reset Tamper Status Temperature Events Log rmal t Triggered Output Device ID Output Current () Output Voltage (VDC) FCP Status 1 Lobby rmal 2 Main ice Graphics Department Inactive 4 SMD Machinery rmal 5 Production Shipping 27. Inactive 7 Receiving 27.2 rmal 8 Loading Docks 27. Status Identification: Fields PS1/ PS2 B C D E F G H IIndicates J K Power L M Supply N O P1 and Q 2 Routput S T voltage U and load. Output Voltage & Load FCP Status Indicates if FCP is triggered or not triggered. B C Reset D E F G H I J Indicates K L M if FCP N O Reset P Qis R triggered S T or not triggered. U Tamper Status Indicates if Tamper is triggered or not triggered.. Temperature Indicates unit temperature (Celsius). C Status Indicates C trouble contact status. B C Battery Status Indicates Battery trouble contact status. D E F G H I J K L M N O P Q R S T U Battery Capacity Indicates mp/hour rating of the connected battery(ies). Battery Voltage Indicates battery voltage of the connected battery(ies). Battery Charge Level Indicates the charge level of the connected battery(ies). B C D Battery Current Indicates the battery charge/discharge rate in amps. E F G H I J K L M N O P Q R S T U Battery Condition Indicates the condition of the connected battery(ies). Battery Service Date Indicates the next service date of the connected battery(ies). Output 1-8 Indicates output. Device ID Descriptive name for the device connected to the output C D E Output F G HCurrent I J() K L MIndicates N O output P Q load R Sin Tamps. U Output Voltage (V) Indicates output voltage in volts. FCP Status Indicates FCP status of the output. B 1 C Help Battery Charge Level Battery Current Battery Condition Battery Service Date LINQ8PD/LINQ8PDCB C Status Battery Status Battery Capacity Battery Voltage C rmal rmal 7 H 27. V v Monday, Sept [2: pm] Minimize D 1 % Charging rmal 11/5/218 Minimize Others Connection Status: OK
14 tes: LINQ8PD/LINQ8PDCB
15 tes: LINQ8PD/LINQ8PDCB
16 tes: ltronix is not responsible for any typographical errors. Product specifications are subject to change without notice th Street, Brooklyn, New York 1122 US, , fax: website: Made in U.S.. IILINQ8PD K2O MEMBER LINQ8PD/LINQ8PDCB
ebridge100spr - EoC Receiver ebridge4spt - 4 Port PoE/PoE+ EoC Transceiver Switch
PLUS Installation Guide ebridge100spr - EoC Receiver - 4 Port PoE/PoE+ EoC Transceiver Switch I.T.E. 43KC Rev. 072313 Overview: The ebridge4sk kit consists of ebridge100spr and which are Coax to CAT-5
Innovative Electronics for a Changing World INDEX
Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.
The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.
GV-I/O Box 8 Ports The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages. Key Features 8 inputs and 8 outputs are provided. Up to 9 pieces of GV-I/O
Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.
IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input
HC Products ILF-100WD User Manual
Internet Line Fault Monitor 2012 HC Security Products Patent Pending 7711 Idlewild RD. Indian Trail, NC 28079 www.hcproductlines.com Tel: 877-908-CCTV (2288) Fax: 888-801-8295 Rev. 2.00 03/22/2012 Table
Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install
TPDIN-Monitor-WEB Web Based Monitor and Control Remote Power Stations Backup Power Systems Solar Systems Wind Powered Systems Industrial Sense & Control Process Automation Congratulations! on your purchase
The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.
GV-I/O Box 16 Ports The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. Key Features 16 inputs and 16 outputs are provided. Up to 9 pieces of GV-I/O
Users manual. TCW181B-CM_R1 Page 1
Ethernet controller TCW181B-CM Users manual 1. Short description TCW181B-CM is 8-channel Ethernet relay board, which is designed to work in IP-based networks and managed by WEB interface or SNMP programs.
SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I-00453 Rev B
User s Manual UPS SERIES Network Interface Card UPS-IPCARD I-00453 Rev B TABLE OF CONTENTS INTRODUCTION............................................................. 3-4 INSTALLATION GUIDE.......................................................
TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module
Panduit Corp. 2010 TDP43ME NetPS PA26306A01 Rev. 01 11-2010 Network Printer Server Control Center for Ethernet Module NOTE: In the interest of higher quality and value, Panduit products are continually
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
JKW-IP. IP Video Entry System. QuikStart Guide
1210 JKW-IP IP Video Entry System QuikStart Guide This is an abbreviated instruction manual for installation purposes. Please see the JKW-IP Installation Manual and JKW-IP Operation Manual for complete
Ethernet controller TCW122B-CM (Firmware version 2.xx) User manual
Ethernet controller TCW122B-CM (Firmware version 2.xx) User manual 1. Short description TCW122B-CM is an Ethernet controller, based on TCW122 hardware. It has 2 digital and 2 analog inputs, 1-Wire interface
HWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
HM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
EMBEDDED ACCESS CONTROL Hardware Installation Guide
EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
1. Hardware Installation
4 Port 10/100M Internet Broadband Router with USB Printer server Quick Installation Guide #4824904AXZZ0 1. Hardware Installation A. System Requirement Before you getting started, make sure that you meet
3.5 Mobile LAN Disk. User Guide
3.5 Mobile LAN Disk User Guide Contents 1. Hardware...2 1.1 Power...2 1.2 Ports...2 1.3 Reset Button...2 1.4 LEDs...2 1.5 Front View...3 1.6 Rear View...3 2. Installation....... 4 2.1 Requirements 4 2.2
3.5 EXTERNAL NETWORK HDD. User s Manual
3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility
User s Manual Network Management Card
User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
APPLICATION NOTE. CC5MPX Digital Camera and IPn3Gb Cellular Modem 10/14. App. Note Code: 3T-Z
APPLICATION NOTE App. Note Code: 3T-Z CC5MPX Digital Camera and IPn3Gb Cellular Modem 10/14 C o p y r i g h t 2 0 1 3-2 0 1 4 C a m p b e l l S c i e n t i f i c ( C a n a d a ) C o r p. Table of Contents
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 1.6 Page 1 Publication Revision No. Control Table Rev. No. Date Contents 1.6 8/22/07 Support connection of multiple WM5.0 devices 1.5 6/18/07 Support
NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2
NetProbe Lite Web Based 8 Channel Sensor Collector User Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission
Firewall VPN Router. Quick Installation Guide M73-APO09-380
Firewall VPN Router Quick Installation Guide M73-APO09-380 Firewall VPN Router Overview The Firewall VPN Router provides three 10/100Mbit Ethernet network interface ports which are the Internal/LAN, External/WAN,
SECURITY / ACCESS / FIRE / SURVEILLANCE
2015 SECURITY / ACCESS / FIRE / SURVEILLANCE More than just power. A leading global provider of power and transmission technologies for professional security system applications, Altronix develops innovative
Link Link sys E3000 sys RE1000
User Guide High Performance Extender Wireless-N Router Linksys Linksys RE1000 E3000Wireless-N Table of Contents Contents Chapter 1: Product Overview 1 Front 1 Top 1 Bottom 1 Back 2 Chapter 2: Advanced
Crow Limited Warranty. Print Version 017
Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose
Multi-Homing Dual WAN Firewall Router
Multi-Homing Dual WAN Firewall Router Quick Installation Guide M73-APO09-400 Multi-Homing Dual WAN Firewall Router Overview The Multi-Homing Dual WAN Firewall Router provides three 10/100Mbit Ethernet
Ethernet Radio Configuration Guide
Ethernet Radio Configuration Guide for Gateway, Endpoint, and Repeater Radio Units April 20, 2015 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com Phone 208-323-1634 FAX 208-323-1834
Intelligent power sockets IQsocket tm IQSB-PicoIP. makes your life more comfortable. User guide. IQSB-PicoIP documentation v1.0 R1
Intelligent power sockets IQsocket tm IQSB-PicoIP makes your life more comfortable User Guide IQSB-PicoIP documentation v1.0 R1 User guide www.iqsocket.eu Important information... 2 1 Introduction... 4
Connecting the DG-102S VoIP Gateway to your network
Contents of Package: DG-102S VoIP Station Gateway Power adapter CD-ROM, including User s Manual Quick Install Guide Requirements: RS-232 Console Cable Two RJ-45 CAT-5 Straight-Through Cables For more information
IP Power Stone 4000 User Manual
IP Power Stone 4000 User Manual Two Outlet Remote AC Power Controller Multi Link, Inc. 122 Dewey Drive Nicholasville, KY 40356 USA Sales and Tech Support 800.535.4651 FAX 859.885.6619 techsupport@multi
Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM
Poseidon 3265 starting guide Poseidon 3265 Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM 1) Connecting Poseidon 3265 1.1) Check DIP switches settings. For installation
Barracuda Link Balancer Administrator s Guide
Barracuda Link Balancer Administrator s Guide Version 1.0 Barracuda Networks Inc. 3175 S. Winchester Blvd. Campbell, CA 95008 http://www.barracuda.com Copyright Notice Copyright 2008, Barracuda Networks
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES
SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES www.unipowerco.com 2014 UNIPOWER LLC All Rights Reserved NORTH AMERICA 3900 Coral Ridge Drive, Coral Springs,
Quick Installation Guide
V48.01 Model: FI8919W Quick Installation Guide Outdoor Pan/Tilt Wireless IP Camera For Windows OS ------- Page 1 For MAC OS ------- Page 15 ShenZhen Foscam Intelligent Technology Co., Ltd Quick Installation
Poseidon2 3268 MANUAL
Poseidon2 3268 MANUAL Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has been tested and is supplied
NIC Controller & Web Interface
NIC Controller & Web Interface 24 x7 Installation and Technical Support 1-866-240-6614 Page 1 of 37 Version 1.1 Table of Contents 1 OVERVIEW... 3 2 INSTALLATION AND TURN-UP... 3 3 MINIMUM REQUIREMENTS...
FI8910W Quick Installation Guide. Indoor MJPEG Pan/Tilt Wireless IP Camera
Model: FI8910W Quick Installation Guide (For Windows OS) (For MAC OS please go to page 17) Indoor MJPEG Pan/Tilt Wireless IP Camera Black White Package Contents IP Camera FI8910W with IR-Cut.x 1 DC Power
1 You will need the following items to get started:
QUICKSTART GUIDE 1 Getting Started You will need the following items to get started: A desktop or laptop computer Two ethernet cables (one ethernet cable is shipped with the _ Blocker, and you must provide
PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400
PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400 PePWave Surf Outdoor Series: Surf AP 200/400-X, PolePoint 400-X, Surf 400-DX User Manual Document Rev. 1.2 July 07 COPYRIGHT & TRADEMARKS
Wifi Pan/Tilt IP Camera User Manual
Wifi Pan/Tilt IP Camera User Manual Rev. 3.0 Software Version 3.00 May. 25 th.2009 Table of Contents 1. PRODUCT VIEWS...3 1.1. PRONT PANEL...3 1.2. BACK PANEL...3 1.3. ACCESSORIES...4 2. SETUP AND STARTUP...5
Power Supply SNMP Interface User Manual for SRL versions
Power Supply SNMP Interface User Manual for SRL versions SNMP-L User Manual 150722(firmware 02r_a12).doc Table of Contents 1. INTRODUCTION... 3 1.1 Default IP Address... 3 2. LOGIN... 4 3. MONITORING &
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
GV-I/O Box 8 Ports. Overview. Key Features. System Requirements. Packing List. DIP Switch
GV-I/O Box 8 Ports Overview The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both and output voltages. Key Features 8 inputs and 8 outputs are provided. Up to 9 pieces of GV-I/O
QUICK INSTALLATION GUIDE
QUICK INSTALLATION GUIDE (v. 1.1) WARNING: This is a class A product. In a domestic environment this product may cause radio interference
Modbus RTU (RS-485) TCP/IP (Ethernet)
Eaton Innovative Technology PEM PC Software Installation and Operation Instruction Manual: IM01005006E Rev. 2 March 2007 Modbus RTU (RS-485) TCP/IP (Ethernet) Effective Date 3/2007 For more information
SATO Network Interface Card Configuration Instructions
SATO Network Interface Card Configuration Instructions Table of Contents 1. Reset of wired/wireless interface card... 3 2. Installing the All-In-One Utility (recommended)... 4 3. Configuring wired/wireless
Quick Start Guide NVR DS-7104NI-SL/W NVR. www.hikvision.com. First Choice For Security Professionals
Quick Start Guide NVR DS-7104NI-SL/W NVR NOTE: For more detailed information, refer to the User s Manual on the CD-ROM. You must use your PC or MAC to access the files. www.hikvision.com Quick Start 1.
F453. TiF453. User guide 10/11-01 PC
F453 TiF453 User guide 10/11-01 PC 2 TiF453 User guide Contents 1. Hardware and Software requirements 4 2. Installation 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements 4 3. Fundamental
Product Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7
Contents Introduction--1 Product Description.................................. 1 Internal Management Features........................... 3 Front Panel........................................ 5 Watchdog
Table of Contents. 1. Introduction...1. 2. PDU Package...2. 3. Function...3. 4. Installation...5. 5. Web Interface...7
PDU User Manual Table of Contents 1. Introduction...1 2. PDU Package...2 3. Function...3 4. Installation...5 5. Web Interface...7 1. Introduction The PDU is an Internet ready device designed and is equipped
ebridge1spr - EoC Receiver ebridge4spt - 4 Port PoE/PoE+ EoC Transceiver Switch
PLUS Installation Guide ebridge1spr - EoC Receiver ebridge4spt - 4 Port PoE/PoE+ EoC Transceiver Switch I.T.E. 43KC Rev. 072313 Overview: The ebridge4sk kit consists of an ebridge1spr and ebridge4spt which
PowerPanel Business Edition USER MANUAL
USER MANUAL Rev. 0.9 2007/10/26 Copyright 2006-2007 Cyber Power Systems, Inc. All rights reserved. PowerPanel Business Edition USER S MANUAL PowerPanel Business Edition provides power management Services.
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
CPEi 800/825 Series. User Manual. * Please see the Introduction Section
CPEi 800/825 Series User Manual * Please see the Introduction Section Contents Introduction...iii Chapter 1: CPEi 800/825 User Guide Overview... 1-1 Powerful Features in a Single Unit... 1-2 Front of the
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R-
MODEL ATC-2004 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2004 is a 4 Port RS232/RS485 to TCP/IP converter integrated with a robust system and network management features
MadCap Software. Upgrading Guide. Pulse
MadCap Software Upgrading Guide Pulse Copyright 2014 MadCap Software. All rights reserved. Information in this document is subject to change without notice. The software described in this document is furnished
IP SENSOR 9216 USER MANUAL IP SENSOR 9216 USER MANUAL
IP SENSOR 9216 USER MANUAL USER MANUAL IP SENSOR 9216 Version: 1.0 2006.08-1 - VER. 1.0, Warning: Any changes to this equipment without permission may cause damages to your equipment! This equipment has
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
GV-Data Capture V3 Series User's Manual
GV-Data Capture V3 Series User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2006 GeoVision, Inc. All rights
Dominion KX II-101-V2
Dominion KX II-101-V2 Quick Setup Guide Thank you for your purchase of the Dominion KX II-101-V2, the economical, full-featured, single-port digital KVM-over-IP device. For details on using the KX II-101-V2,
Please use only wired network connections to configure the router.
Note Please use only wired network connections to configure the router. Connect the WAN port on your Router to the Modem s LAN port with an Ethernet cable. Note If connecting the TL-WR543G to the WISP
IntraVUE Plug Scanner/Recorder Installation and Start-Up
IntraVUE Plug Scanner/Recorder Installation and Start-Up The IntraVUE Plug is a complete IntraVUE Hardware/Software solution that can plug directly into any network to continually scan and record details
Allworx Installation Course
VPN Hello and welcome. In the VPN section we will cover the steps for enabling the VPN feature on the Allworx server and how to set up a VPN connection to the Allworx System from your PC. Page 1 VPN The
USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog
USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...
Configuring the CyberData VoIP 4-Port Zone Controller with Audio Out
NetVanta Unified Communications Technical Note Configuring the CyberData VoIP 4-Port Zone Controller with Audio Out Introduction The CyberData Voice over Internet Protocol (VoIP) zone controller enables
USB Edition TM-STD30 User Guide
USB Edition TM-STD30 User Guide 1 Rev 4.0.8 http://www.temperaturealert.com/ 2012 Temperature@lert User Guide Thank you for choosing Temperature@lert. The USB Edition monitors the ambient temperature and
LifeSize Networker Installation Guide
LifeSize Networker Installation Guide November 2008 Copyright Notice 2006-2008 LifeSize Communications Inc, and its licensors. All rights reserved. LifeSize Communications has made every effort to ensure
SSL-VPN 200 Getting Started Guide
Secure Remote Access Solutions APPLIANCES SonicWALL SSL-VPN Series SSL-VPN 200 Getting Started Guide SonicWALL SSL-VPN 200 Appliance Getting Started Guide Thank you for your purchase of the SonicWALL SSL-VPN
Quick Installation Guide DAP-1360. Wireless N 300 Access Point & Router
DAP-1360 Wireless N 300 Access Point & Router BEFORE YOU BEGIN Delivery Package Access point DAP-1360 Power adapter DC 12V Ethernet cable (CAT 5E) (brochure). If any of the items are missing, please contact
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...
Monnit Wi-Fi Sensors. Quick Start Guide
Monnit Wi-Fi Sensors Quick Start Guide Inside the Box You should find the following items in the box: Monnit Wi-Fi (MoWi ) Sensors 2 x AA Batteries for Each MoWi Sensor Quick Start Guide Note: A MoWi USB
Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)
Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time
TR-7W Configuration Guide. Before You Start
TR-7W Configuration Guide Before You Start Take a few moments before you start to make the following simple checks. A few moments spent before you start installing your system can save a lot of time later
Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6
Contents Introduction 1 Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5 Initial Configuration Requirements 6 Overview 6 Setup Wizard 7 Status, Alarm,
DVG-2101SP VoIP Telephone Adapter
This product can be set up using any current web browser, i.e., Internet Explorer 6 or Netscape Navigator 6.2.3. DVG-2101SP VoIP Telephone Adapter Before You Begin 1. If you purchased this VoIP Telephone
Turn off all of your network devices, including your computer, Modem and the Router.
Note The product model shown in this part is TL-R460, as an example. Turn off all of your network devices, including your computer, Modem and the Router. Connect the WAN port on your Router to the Modem
Meraki MX50 Hardware Installation Guide
Meraki MX50 Hardware Installation Guide January 2011 Copyright 2010, Meraki, Inc. www.meraki.com 660 Alabama St. San Francisco, California 94110 Phone: +1 415 632 5800 Fax: +1 415 632 5899 Copyright: 2010
Chapter 4 Management. Viewing the Activity Log
Chapter 4 Management This chapter describes how to use the management features of your NETGEAR WG102 ProSafe 802.11g Wireless Access Point. To get to these features, connect to the WG102 as described in
Assign a static IP address 192.168.1.100 for your computer. Please refer to the T3 in Troubleshooting guide if you need assistance.
Assign a static IP address 192.168.1.100 for your computer. Please refer to the T3 in Troubleshooting guide if you need assistance. Connect to the Access Point with the Ethernet cable or via wireless.the
10/2011 - English Edition 1. Quick Start Guide. NWA1100N-CE CloudEnabled Business N Wireless Access Point
10/2011 - English Edition 1 Quick Start Guide NWA1100N-CE CloudEnabled Business N Wireless Access Point Package Contents - 1 x ZyXEL NWA1100N-CE Access Point - 2 x Detachable Antennas - 1 x Power Adapter
3.5 LAN HDD Enclosure User s Manual
3.5 LAN HDD Enclosure User s Manual NOTE: 1. USB and LAN can t be used at the same time. 2. HDD should be formatted as FAT32. Please check Disk utility section in this manual. 3. For internet FTP usage,
User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS
MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed
IDDERO TOUCH PANELS. Video door phone configuration. www.iddero.com 120130-02
IDDERO TOUCH PANELS Video door phone configuration www.iddero.com 120130-02 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 INSTALLATION... 3 3 INITIAL CONFIGURATION... 4 4 2N HELIOS IP VIDEO DOOR PHONES... 5
Product Guide CM-Relay
Product Guide CM-Relay www.theclimate.co.uk tel: 01491 410913 The Climate, Badgers Bank, Harpsden, Henley-on-Thames, Oxfordshire RG9 4HL. Overview CM-Relay combines climate monitoring with remote relay
1ZSC000857-ABH en. Intelligent monitoring system, type TEC Installation and commissioning guide
1ZSC000857-ABH en Intelligent monitoring system, type TEC Installation and commissioning guide Declaration of conformity The manufacturer ABB AB Components SE-771 80 LUDVIKA Sweden Hereby declares that
6.0. Getting Started Guide
6.0 Getting Started Guide Netmon Getting Started Guide 2 Contents Contents... 2 Appliance Installation... 3 IP Address Assignment (Optional)... 3 Logging In For the First Time... 5 Initial Setup... 6 License
Wireless G Broadband quick install
Wireless G Broadband Router quick install guide Model 503693 INT-503693-QIG-0608-02 Thank you for purchasing the INTELLINET NETWORK SOLUTIONS Wireless G Broadband Router, Model 503693. This quick install
User Manual Version 4.0.0.5. User Manual A20 / A50 / A100 / A250 / A500 / A1000 / A2000 / A4000
User Manual Version 4.0.0.5 User Manual A20 / A50 / A100 / A250 / A500 / A1000 / A2000 / A4000 I Endpoint Protector Appliance User Manual Table of Contents 1. Endpoint Protector Appliance Setup... 1 1.1.
PRILINK PRI Management System
www.prilink.com PRILINK PRI MANAGEMENT SSTEM INSTALLATION GUIDE PRI Management PRILINK PRI Management System Installation Guide Version 3.0, Rev. 12-01-24 Page 1 Table of Contents 1 HARDWARE INSTALLATION...
Barracuda Link Balancer
Barracuda Networks Technical Documentation Barracuda Link Balancer Administrator s Guide Version 2.2 RECLAIM YOUR NETWORK Copyright Notice Copyright 2004-2011, Barracuda Networks www.barracuda.com v2.2-110503-01-0503
Ethernet Interface Manual Thermal / Label Printer. Rev. 1.01 Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2
Ethernet Interface Manual Thermal / Label Printer Rev. 1.01 Metapace T-1 Metapace T-2 Metapace L-1 Metapace L-2 Table of contents 1. Interface setting Guiding...3 2. Manual Information...4 3. Interface