1 Complete Data Center

2 Compact. Validated. Turnkey-ready. Complete-Data-Center for virtual environments Has the IT environment of your company grown over time historically? Do you face continuous growth and have a high expectation on IT security? Run-rate changes are complicated and time consuming! Our Complete-Data-Center is exactly the right solution you are looking for. The CDC system is a safe, fire-protected and vandal-proof IT container. Only renowned manufacturers provide the necessary infrastructure components for secure operation. They match perfectly best-practice-design and commendable, instant ease of use. A 30 m² turnkey-ready system only requires connection to a network and power. The userside contribution of the active IT technology takes place independently of the manufacturer. Coarse and fine art are spatially separated from each other and thus facilitate the implementation of safety-related access restrictions. Besides, the system distinguishes itself by its inherent flexibility completely independent of application case, whether its an expansion due to limited space or an opportunity to provide a redundant infrastructure: Our CDC container is always the right choice. A further added benefit is that: the CDC is not visible from the outside as is the case with a conventional data-center. Flush mounting parts are not only visually appealing, they also simplify overall handling. Fire prevention with oxygen reduction form part of the standard design. Optimised reliability and reduced operation costs are assured by most efficient precision air conditioning and UPS systems. The complete system is based on the fundamentals of TÜV Rheinland Consulting criteria catalog and is instantaneously suitable CAT 2 classification. In addition, the possibility of a RC4 classification exists to German Institute for Standardisation EN 1630 for the container shell. The whole security concept can be expanded on customer request. The following technology experts are involved in the realisation of your turnkey-ready CDC container: W DENIOS AG (fire compartment) W Panduit (passive IT infrastructure) W Socomec UPS GmbH (safe, uninterruptible power supply) W STULZ GmbH (air conditioning) W Tyco Security Products EMEA (Safety & Security technology) W WAGNER Group GmbH (fire detection, fire fighting and fire prevention technology) CHG-MERIDIAN is available as a partner modeling the right financing options of your CDC solution. Best-practice-design The tried-and-tested room layout to suit all the requirements of the components can be called undoubtedly best practice. Coarse technology (FM) and fine technology (IT) are separated by a grid wall. Access restrictions, for example, for maintenance personnel, is easier to implement.

3 The technical department In the technology space the following components are accommodated: W Air conditioning technology in redundant design W Early fire detection and fire prevention system W Fire alarm control panel (FACP) W Uninterruptible Power Supply (UPS) W Low-voltage main distribution (LVMD) W Video management, access control and monitoring system with operator station GreenPower 2.0 reliable power supply W Highest certified efficiency for reducing economic power consumption W Maximum availability about single- and redundant architectures W UPS design kw = kva for data center and IT loads Intevo Security Management & Monitoring System W Access control system W Integrated IP video solution W Monitoring for FACP, UPS, air condition etc. W Optional: operation and service by Web and App (ios / Android) OxyReduct fire protection system W Fire prevention by oxygen reduction W Protective atmosphere can be maintained as long as desired W Easy to maintain W High functional reliability CyberAir 3 Closed-circuit precision air-conditioning system W Operational reliability through redundant cooling design W Efficient operation by EC fan and optional EC compressor W Scalable in size and performance W Components requiring maintenance are front accessible Double safety in case of fire The container shell provides full fire protection against risks both internally and externally. In addition to the fire prevention system via the reduction of oxygen inside the container, no emergency power shut down is required in the case of fire. Meanwhile, the data availability remains guaranteed.

4 The server room For the room layout there are several options available. Up to seven IT equipment cabinets with fully usable 42 HU can be easily accommodated. Convenient access to the racks is guaranteed regardless of the complex configurations. Above the IT cabinets, waste heat is combined and discharged into an air channel. The handling the highest packing densities thus also energetically not a problem. The system does feature preinstalled basic cabling infrastructures. The complete media distribution is installed by means of a specialised overhead cable pathway. Due to the omission of a false floor comfortable access heights can be achieved. Net-Access data closet system W Designed with IT hardware manufacturers for maximum energy efficiency W Thorough hot-/cold aisle separation W Optimum room condition by vertical exhaust system W Seamless and fully integrated cable management W WyrGrid flexible cable pathways W QuickNet pre-terminated high-speed cabling

5 Ten good reasons... for your high-performance CDC 1 Review of your IT infrastructure to optimise the level of your CDC 6 Through our established and internationally operating partners, your long term budgeting, planning and reliability are assured 2 Critical factors such as air conditioning, fire protection and secure power are optimised for increased reliability and efficiency 7 CDC provides excellent value for money 3 Growth and the increasing demands of the physical IT industry are considered and planned for 8 Whether you are purchasing or leasing, we have the packages to meet your service and maintenance requirements 4 One central location and a single contact, per system owner, for all infrastructure communications simplifies the process and provides cost savings in IT and facilities management 9 A turnkey-ready CDC can be available to you in a minimal amount of time 5 You will receive a state of the art, tried and tested solution, specifically designed for your needs 10 Your CDC ensures future challenges can be overcome safely Flexibility by optimised interior design a sophisticated and integrated package

6 Contact person Your team of specialists Guidance: Technical Consulting, Sales and Implementation Conceptual Design, Consulting and Funding: DENIOS AG Dehmer Straße Bad Oeynhausen Phone CHG-MERIDIAN AG Franz-Beer-Straße Weingarten Phone chg-meridian@cdc-info.com The following technology experts are involved in the realisation of your turnkey-ready CDC container: Panduit Deutschland Mainzer Landstraße Frankfurt panduit@cdc-info.com Socomec UPS GmbH Heppenheimer Straße Mannheim socomec@cdc-info.com STULZ GmbH Holsteiner Chaussee Hamburg stulz@cdc-info.com Conceptual Design and End-to-End Project Monitoring: Tyco Security Products Heathrow Boulevard Bath Road - West Drayton Heathrow - United Kingdom - UB7 0DQ tyco@cdc-info.com WAGNER Group GmbH Schleswigstraße Langenhagen wagner@cdc-info.com TÜV Rheinland Consulting GmbH Am Grauen Stein Köln consulting@de.tuv.com Please send your request: info@cdc-info.com

RiMatrix S Make easy.

RiMatrix S Make easy. RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power

More information

DATACENTER MÜNCHEN 2. Munich s Number One Address for Your Data

DATACENTER MÜNCHEN 2. Munich s Number One Address for Your Data DATACENTER MÜNCHEN 2 Munich s Number One Address for Your Data We Use the Latest Technology for the Security of Your Systems Contents Your Goals 2 Compound and Buildings 4 Security 6 Infrastructure 8 Free

More information

DATACENTER COLOCATION. Flexible, Secure and Connected

DATACENTER COLOCATION. Flexible, Secure and Connected DATACENTER COLOCATION Flexible, Secure and Connected Flexible Solutions for Your Requirements Contents Your Goals 2 Compound and Buildings 4 Security 6 Infrastructure 8 Free Choice 10 Good Reasons 12 Our

More information

DATACENTER BERLIN Definitely a Good Perspective

DATACENTER BERLIN Definitely a Good Perspective DATACENTER BERLIN Definitely a Good Perspective We Do not Take any Chances: For the Security of Your IT Systems. Contents Your Goals 2 Compound and Buildings 4 Security 6 Infrastructure 8 Free Choice 14

More information

Europe s most modern data center 09/2013 09/2015 09/2013 09/2015 APPROVED ENERGY EFFICIENT DATA CENTER SINGLE SITE INTERCONNECTED SITE

Europe s most modern data center 09/2013 09/2015 09/2013 09/2015 APPROVED ENERGY EFFICIENT DATA CENTER SINGLE SITE INTERCONNECTED SITE Europe s most modern data center SINGLE SITE 09/2013 09/2015 INTERCONNECTED SITE 09/2013 09/2015 APPROVED ENERGY EFFICIENT DATA CENTER Significantly more performance per data center space The market for

More information

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Dealing with Thermal Issues in Data Center Universal Aisle Containment Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe Daniele.Tordin@Panduit.com AGENDA Business Drivers Challenges

More information

DATACENTER MUNICH 2. Munich s Number One Address for Your Data

DATACENTER MUNICH 2. Munich s Number One Address for Your Data DATACENTER MUNICH 2 Munich s Number One Address for Your Data We Use the Latest Technology for the Security of Your Systems Contents Your Goals 2 Compound and Buildings 4 Security 6 Infrastructure 8 Free

More information

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009 Optimum Climate Control For Datacenter - Case Study T. Prabu March 17 th 2009 Agenda 2 About EDEC (Emerson) Facility Data Center Details Design Considerations & Challenges Layout Design CFD Analysis Of

More information

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized! www.knuerr.

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized! www.knuerr. HIGH DENSITY COOLING SOLUTIONS by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized! optimiert! Setting benchmarks. Being the

More information

APC APPLICATION NOTE #112

APC APPLICATION NOTE #112 #112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.

More information

Airflow Simulation Solves Data Centre Cooling Problem

Airflow Simulation Solves Data Centre Cooling Problem Airflow Simulation Solves Data Centre Cooling Problem The owner s initial design for a data centre in China utilized 40 equipment racks filled with blade servers spread out in three rows along the length

More information

IPSIP M series-m Modular Data Center

IPSIP M series-m Modular Data Center IPSIP M series-m Modular Data Center IPSIP MODULAR TECHNOLOGIES. 1 With the rapid development of cloud computing and mobile Internet businesses, the growth of IT density and energy consumption are bringing

More information

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY Public Sector ICT Special Working Group SERVER ROOM ENERGY EFFICIENCY This guide is one of a suite of documents that aims to provide guidance on ICT energy efficiency.

More information

White Paper Data Centre in a Standard Container

White Paper Data Centre in a Standard Container White Paper Data Centre in a Standard Container Contents Contents... 1 List of illustrations... 3 List of tables... 3 Executive summary... 4 Introduction... 5 Objective and requirement... 6 Rittal Data

More information

Data Center Trend: Distributed Power in the White Space

Data Center Trend: Distributed Power in the White Space Data Center Trend: Distributed Power in the White Space By Jason Anderson Product Line Manager Eaton Executive summary Cloud computing vendors and colocation data centers make every effort to maximize

More information

STULZ View On DataCenter Cooling

STULZ View On DataCenter Cooling STULZ View On DataCenter Cooling Stulz Was Founded In Hamburg (Germany) In 1947 And Has 5 Production Sites And 14 Subsidiaries In 14 Countries. We Are Represented By Partners In Over 110 Countries. Stulz

More information

DATACENTER CAMPUS FRANKFURT. Plan for Every Second

DATACENTER CAMPUS FRANKFURT. Plan for Every Second DATACENTER CAMPUS FRANKFURT Plan for Every Second We Give All Our Energy and Dedication to Create Safe Environments by Making Risks Manageable Contents Your Goals 2 Compound and Buildings 4 Security 6

More information

engineering service Reliable Data Center. With TÜV Rheinland experts

engineering service Reliable Data Center. With TÜV Rheinland experts engineering service Reliable Data Center. With TÜV Rheinland experts It. energy A changed IT landscape brings new challenges. With the ever-growing digitization, the reliability of data centers and server

More information

Data Centers. Mapping Cisco Nexus, Catalyst, and MDS Logical Architectures into PANDUIT Physical Layer Infrastructure Solutions

Data Centers. Mapping Cisco Nexus, Catalyst, and MDS Logical Architectures into PANDUIT Physical Layer Infrastructure Solutions Data Centers Mapping Cisco Nexus, Catalyst, and MDS Logical Architectures into PANDUIT Physical Layer Infrastructure Solutions 1 Introduction The growing speed and footprint of data centers is challenging

More information

Energy-efficient & scalable data center infrastructure design

Energy-efficient & scalable data center infrastructure design Seminar am 30. September 2010 in Wetzlar Nachhaltigkeit durch UPI (Unified Physical Infrastructure) Vortrag von Stefan Fammler: Energieeffiziente Strategien im Rechenzentrum Energy-efficient & scalable

More information

Standardised Data centres. Sales presentation

Standardised Data centres. Sales presentation Standardised Data centres 1 Standardised Data Centres l Motivation ll Change of paradigm lll Rittal s Data centre concept lv Benefits V Summary Standardised Data Centre Motivation Does every data centre

More information

Wireless Networks and Power Quality

Wireless Networks and Power Quality Will installing wireless networking change my back-up power requirements? What data do I need to know in order to determine my wireless network back-up power requirements? What other issues should I consider

More information

COMPARISON OF EFFICIENCY AND COSTS BETWEEN THREE CONCEPTS FOR DATA-CENTRE HEAT DISSIPATION

COMPARISON OF EFFICIENCY AND COSTS BETWEEN THREE CONCEPTS FOR DATA-CENTRE HEAT DISSIPATION COMPARISON OF EFFICIENCY AND COSTS BETWEEN THREE CONCEPTS FOR DATA-CENTRE HEAT DISSIPATION 1/16 Contents: 1. Introduction: the increasing importance of energy efficiency 1.1 Power consumers in the data

More information

Europe s greenest data center

Europe s greenest data center Europe s greenest data center datadock represents the perfect cooperation of humans, machines and nature. In more than three years of planning and construction and with a total budget of over 17 million

More information

Case Study. Cool and green: Citigroup s Frankfurt Data Center

Case Study. Cool and green: Citigroup s Frankfurt Data Center Zug, April 16, 2015 Cool and green: Citigroup s Frankfurt Data Center In Frankfurt, Siemens helps optimize Citigroup s data center. When it comes to building automation, security technology and power supply,

More information

DATACENTER Vienna 1. Scalable, Safe and Innovative

DATACENTER Vienna 1. Scalable, Safe and Innovative DATACENTER Vienna 1 Scalable, Safe and Innovative Designed, built and optimized for the security of your data Contents Your Goals 2 Compound and Buildings 4 Energy Efficiency 6 Security 10 Infrastructure

More information

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc. High Density Data Centers Fraught with Peril Richard A. Greco, Principal EYP Mission Critical Facilities, Inc. Microprocessors Trends Reprinted with the permission of The Uptime Institute from a white

More information

How To Build A T7 Rack For Information Technology

How To Build A T7 Rack For Information Technology THE NEXT GENERATION RACK FOR INFORMATION TECHNOLOGY THE RACK CABINET FOR INFORMATION TECHNOLOGY T7, THE HI-TECH HEART OF THE BLADESHELTER SYSTEM The real answer to the requirements of: Safety Versatility

More information

SERVER ROOM CABINET INSTALLATION CONCEPTS

SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the

More information

Microsoft Technology Center: Philadelphia

Microsoft Technology Center: Philadelphia A Customer Success from the Experts in Business-Critical Continuity TM. Background Microsoft Technology Center: Philadelphia Microsoft Technology Centers are collaborative, state-of-the-art facilities

More information

Best Practices for Wire-free Environmental Monitoring in the Data Center

Best Practices for Wire-free Environmental Monitoring in the Data Center White Paper 11800 Ridge Parkway Broomfiled, CO 80021 1-800-638-2638 http://www.42u.com sales@42u.com Best Practices for Wire-free Environmental Monitoring in the Data Center Introduction Monitoring for

More information

DATACENTER FRANKFURT 3. Well Served with Fresh Air

DATACENTER FRANKFURT 3. Well Served with Fresh Air DATACENTER FRANKFURT 3 Well Served with Fresh Air New Technology for Chilled Rooms: Indirect Adiabatic External Air Cooling Contents Your Goals 2 Compound and Buildings 4 Security 6 Infrastructure 8 Free

More information

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY The Aegis Services Power and Assessment Service provides an assessment and analysis of your data center facility and critical physical

More information

JAWAHARLAL NEHRU UNIVERSITY

JAWAHARLAL NEHRU UNIVERSITY School of Biotechnology JAWAHARLAL NEHRU UNIVERSITY New Delhi 110 067 Tender No. JNU/SBT/DBT-BUILDER/Data Centre/2015-16 Sealed Quotation for the establishment of a Data Centre for High-End Computational

More information

DATACENTER ZURICH. Well Positioned for Security

DATACENTER ZURICH. Well Positioned for Security DATACENTER ZURICH Well Positioned for Security We Design, Build and Operate Data Centres with All Our Energy and with Dedication. Contents Your Goals 2 Compound and Buildings 4 Security 6 Infrastructure

More information

Scalable. Affordable. Flexible. Fast.

Scalable. Affordable. Flexible. Fast. Modular Data Center Solutions Scalable. Affordable. Flexible. Fast. Build the data center you need today with the flexibility to meet tomorrow s challenges The only constant in business is change. Fluctuations

More information

IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world

IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world IT Cooling Solutions DFC² Direct Free Cooling for Data Centres Energy-efficient, reliable and available around the world Worldwide Green Engineering with Direct Free Cooling from STULZ Forward thinking

More information

IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world

IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world IT Cooling Solutions DFC² Direct Free Cooling for Data Centres Energy-efficient, reliable and available around the world Worldwide Green Engineering with Direct Free Cooling from STULZ Forward thinking

More information

Managing Data Centre Heat Issues

Managing Data Centre Heat Issues Managing Data Centre Heat Issues Victor Banuelos Field Applications Engineer Chatsworth Products, Inc. 2010 Managing Data Centre Heat Issues Thermal trends in the data centre Hot Aisle / Cold Aisle design

More information

In Row Cooling Options for High Density IT Applications

In Row Cooling Options for High Density IT Applications In Row Cooling Options for High Density IT Applications By Ramzi Y. Namek, PE, LEED AP, BD+C; Director of Engineering 1 Users wishing to deploy high density IT racks have several In Row Cooling solutions

More information

So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org

So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org So you want to build a data centre? Who do you contact? How do you work out what

More information

Choosing Close-Coupled IT Cooling Solutions

Choosing Close-Coupled IT Cooling Solutions W H I T E P A P E R Choosing Close-Coupled IT Cooling Solutions Smart Strategies for Small to Mid-Size Data Centers Executive Summary As high-density IT equipment becomes the new normal, the amount of

More information

Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs

Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs WHITE PAPER Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs By Lars Strong, P.E., Upsite Technologies, Inc. 505.798.000 upsite.com Reducing Room-Level

More information

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,

More information

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity Modular architecture for high power UPS systems A White Paper from the experts in Business-Critical Continuity Abstract Today, more than ever before, energy efficiency and cost-savings are among the top

More information

Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems

Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems Miracel 19 rack platform for data center, telecommunication and network technology Rack & Integrated Enclosure Systems The Miracel innovation rack multi-talented, distinguished, integrative The Miracel

More information

The Different Types of Air Conditioning Equipment for IT Environments

The Different Types of Air Conditioning Equipment for IT Environments The Different Types of Air Conditioning Equipment for IT Environments By Tony Evans White Paper #59 Executive Summary Cooling equipment for an IT environment can be implemented in 10 basic configurations.

More information

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design. Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design. Equinix Telecity Kvastvägen 25-29 128 62 Sköndal Stockholm Sweden Tel: +46 (0) 8 799 3800 se.info@telecity.com www.telecitygroup.se

More information

Upgrading the PRS datacentres: space requirement. S. S. Mathur, GM-IT, CRIS

Upgrading the PRS datacentres: space requirement. S. S. Mathur, GM-IT, CRIS Upgrading the PRS datacentres: space requirement S. S. Mathur, GM-IT, CRIS PRS / UTS scenario: then and now Year 2000 PRS: 600 locations UTS: 0 locations Year 2008 PRS 1600 locations E-ticketing Passengers

More information

Introducing UNSW s R1 Data Centre

Introducing UNSW s R1 Data Centre Introducing UNSW s R1 Data Centre R1-DC Our New High Density Data Centre Right here Right now - Welcome to our newest UNSW Data Centre R1-DC R1 Location on UNSW Randwick campus. Keeping it in the family

More information

Data Center Power Consumption

Data Center Power Consumption Data Center Power Consumption A new look at a growing problem Fact - Data center power density up 10x in the last 10 years 2.1 kw/rack (1992); 14 kw/rack (2007) Racks are not fully populated due to power/cooling

More information

Power Feeding Equipment for Optical Submarine Cable Systems

Power Feeding Equipment for Optical Submarine Cable Systems Power Feeding Equipment for Optical Submarine Cable Systems KANEKO Tomoyuki, CHIBA Yoshinori, KUNIMI Kaneaki, NAKAMURA Tomotaka Abstract A submarine cable system is fed power from power feeding equipment

More information

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency

More information

Technical specifications. Containerized data centre NTR CDC 40f+

Technical specifications. Containerized data centre NTR CDC 40f+ Technical specifications Containerized data centre NTR CDC 40f+ CONTENT 1 THE PURPOSE OF CDC... 3 2 BASIC PROPERTIES... 4 2.1 EXTERNAL DIMENSIONS... 4 2.2 INSTALLATION REQIREMENTS... 4 2.3 ELECTRICAL CONNECTION

More information

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION The heat load in data centers is increasing rapidly, the adaptation of a cooling strategy is often necessary. Many data centers and server rooms use

More information

Elements of Energy Efficiency in Data Centre Cooling Architecture

Elements of Energy Efficiency in Data Centre Cooling Architecture Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total

More information

OCTOBER 2010. Layer Zero, the Infrastructure Layer, and High-Performance Data Centers

OCTOBER 2010. Layer Zero, the Infrastructure Layer, and High-Performance Data Centers Layer Zero, the Infrastructure Layer, and The demands on data centers and networks today are growing dramatically, with no end in sight. Virtualization is increasing the load on servers. Connection speeds

More information

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences November 2011 Powered by DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no

More information

Thermal Optimisation in the Data Centre

Thermal Optimisation in the Data Centre Thermal Optimisation in the Data Centre Best Practices for achieving optimal cooling performance and significant energy savings in your data centre 1. Thermal analysis 2. Cold-Aisle-Containment 3. Seal

More information

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers Deploying a Vertical Exhaust System www.panduit.com WP-09 September 2009 Introduction Business management applications and rich

More information

Bob Evans Farms Receives Cash Incentive to Colocate with Cologix Through Innovative Efficiency Program

Bob Evans Farms Receives Cash Incentive to Colocate with Cologix Through Innovative Efficiency Program Bob Evans Farms Receives Cash Incentive to Colocate with Cologix Through Innovative Efficiency Program AEP Ohio s Data Center Program Validates and Rewards Energy Savings Gained from Migrating from In-house

More information

Colocation and Cloud Hosting Solutions. Build a strong and efficient physical infrastructure that delivers service reliability and profitability

Colocation and Cloud Hosting Solutions. Build a strong and efficient physical infrastructure that delivers service reliability and profitability Colocation and Cloud Hosting Solutions Build a strong and efficient physical infrastructure that delivers service reliability and profitability 2 Dependability and Deployment Speed that Improves Your Bottom

More information

Unified Physical Infrastructure (UPI) Strategies for Data Center Networking

Unified Physical Infrastructure (UPI) Strategies for Data Center Networking Unified Physical Infrastructure (UPI) Strategies for Data Center Networking Physical Infrastructure Considerations for Smart Data Center Consolidation www.panduit.com WP-08 February 2009 Introduction Improving

More information

- White Paper - Data Centre Cooling. Best Practice

- White Paper - Data Centre Cooling. Best Practice - White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH

More information

Server Platform Optimized for Data Centers

Server Platform Optimized for Data Centers Platform Optimized for Data Centers Franz-Josef Bathe Toshio Sugimoto Hideaki Maeda Teruhisa Taji Fujitsu began developing its industry-standard server series in the early 1990s under the name FM server

More information

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems Knürr CoolAdd The universal retrofit solution against overheating in server racks Rack & Enclosure Systems Knürr CoolAdd When cold air is no longer enough! Data centers are subject to constant changes:

More information

SMARTPLAY7. Increase your Deal Size and Profitability with SmartPlays

SMARTPLAY7. Increase your Deal Size and Profitability with SmartPlays SMARTPLAY7 Increase your Deal Size and Profitability with SmartPlays - Comstor and Panduit have joined forces to promote the power and flexibility of UCS combined with market leading energy efficient enclosures.

More information

State of the Art Energy Efficient Data Centre Air Conditioning

State of the Art Energy Efficient Data Centre Air Conditioning - White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...

More information

System solution for data centres

System solution for data centres 1 System solution for data centres Energy-efficient air conditioning with ServeLine Cooling IT infrastructure, high availability, low energy costs and communication with DCIM systems all in one from your

More information

Integrated Building Automation Solutions for Operators

Integrated Building Automation Solutions for Operators Integrated Building Automation Solutions for Operators Maximised availability. Minimised operating costs. Comfort or efficiency? Beckhoff Building Automation lets you have it both ways. Real-estate operators

More information

NAISSUS THERMAL MANAGEMENT SOLUTIONS

NAISSUS THERMAL MANAGEMENT SOLUTIONS NAISSUS THERMAL MANAGEMENT SOLUTIONS HIGH PERFORMANCE CLOSED LOOP WATER COOLING SYSTEM NTMS30 30kW SYSTEM Cool the servers, not the room! NAISSUS THERMAL MANAGEMENT SOLUTIONS HIGH PERFORMANCE CLOSED LOOP

More information

APC APPLICATION NOTE #92

APC APPLICATION NOTE #92 #92 Best Practices for Designing Data Centers with the InfraStruXure InRow RC By John Niemann Abstract The InfraStruXure InRow RC is designed to provide cooling at the row and rack level of a data center

More information

The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space.

The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space. The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space. Terminology: Telco: Dmarc: NOC: SAN: GENSET: Switch: Blade

More information

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw Knürr DCL Modular Rack Cooling from 6 kw to 60 kw Emerson Network Power Business-Critical Continuity so your success continues! Core competencies AC Power Connectivity DC Power Embedded Computing Embedded

More information

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

Unified Physical Infrastructure (UPI) Strategies for Thermal Management Unified Physical Infrastructure (UPI) Strategies for Thermal Management The Importance of Air Sealing Grommets to Improving Smart www.panduit.com WP-04 August 2008 Introduction One of the core issues affecting

More information

DataCenter 2020. Data Center Management and Efficiency at Its Best. OpenFlow/SDN in Data Centers for Energy Conservation.

DataCenter 2020. Data Center Management and Efficiency at Its Best. OpenFlow/SDN in Data Centers for Energy Conservation. DataCenter 2020. Data Center Management and Efficiency at Its Best. OpenFlow/SDN in Data Centers for Energy Conservation. Dr. Rainer Weidmann, DC Architecture & DC Innovation Dr. Rainer Weidmann, DC Architecture

More information

Server Room Thermal Assessment

Server Room Thermal Assessment PREPARED FOR CUSTOMER Server Room Thermal Assessment Analysis of Server Room COMMERCIAL IN CONFIDENCE MAY 2011 Contents 1 Document Information... 3 2 Executive Summary... 4 2.1 Recommendation Summary...

More information

THE KEY TO DATA CENTRE INFRASTRUCTURE

THE KEY TO DATA CENTRE INFRASTRUCTURE ENCLOSURES, RACKS & CABINETS THE KEY TO DATA CENTRE INFRASTRUCTURE PAGE 52 www.insidenetworksme.com JULY 15 Jonathan Duncan, Data Centre and Integrated Solutions Director, Schneider Electric, outlines

More information

Cabcon. Data Centre Solutions. www.cabcon.co.uk. an acal group company UK +44 (0)1189 122980 IRE (00353) 1 629 2640

Cabcon. Data Centre Solutions. www.cabcon.co.uk. an acal group company UK +44 (0)1189 122980 IRE (00353) 1 629 2640 Data Centre Solutions www.cabcon.co.uk UK +44 (0)1189 122980 IRE (00353) 1 629 2640 About Us are a specialist distributor of copper, fibre, power, security, active and cable management products for the

More information

The Ultimate in Scale-Out Storage for HPC and Big Data

The Ultimate in Scale-Out Storage for HPC and Big Data Node Inventory Health and Active Filesystem Throughput Monitoring Asset Utilization and Capacity Statistics Manager brings to life powerful, intuitive, context-aware real-time monitoring and proactive

More information

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits. This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits. DCD, DCOM, DCE DESIGN IMPLEMENTATION BEST PRACTICE OPERATION & MANAGEMENT DATA

More information

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME) SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME) Construction Criteria The unit costs for ADP Mainframe space types are based on the construction quality and design features in the following

More information

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009 Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009 Agenda Overview - Network Critical Physical Infrastructure Cooling issues in the Server Room

More information

European Code of Conduct for Data Centre. Presentation of the Awards 2016

European Code of Conduct for Data Centre. Presentation of the Awards 2016 European Code of Conduct for Data Centre Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results European

More information

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE Best practices for airflow management and cooling optimisation AIRFLOW MANAGEMENT COLD AND HOT AISLE CONTAINMENT DC ASSESSMENT SERVICES Achieving true 24/7/365

More information

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME 2 AGENDA SESSION -1 What is Data Center? SESSION -2 Equipment and Components SESSION -3 Standard in designing Data Center

More information

Anixter ipassured SM for Data Centres. Products. Technology. Services. Delivered Globally.

Anixter ipassured SM for Data Centres. Products. Technology. Services. Delivered Globally. Anixter ipassured SM for Data Centres Products. Technology. Services. Delivered Globally. Anixter is a leading global supplier of communications and security products, electrical and electronic wire and

More information

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM Data Center Rack Systems Key to Business-Critical Continuity A White Paper from the Experts in Business-Critical Continuity TM Executive Summary At one time, data center rack enclosures and related equipment

More information

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity Liebert Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment Precision Cooling For Business-Critical Continuity The Intelligent Data Center Cooling Solution: Liebert Trust the industry

More information

Hosting. Simply Different. www.iso-gruppe.com

Hosting. Simply Different. www.iso-gruppe.com Hosting. Simply Different. www.iso-gruppe.com Hosting. ISO Professional Services offers more All the SAP expertise of the ISO Group is focused in ISO Professional Services, which is among the firmly established

More information

100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G

100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G 100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G The Opportunity Jones Lang LaSalle, Inc. (the Broker ) is please to offer the fee simple interest in 100 Locust Avenue (the

More information

Benefits of. Air Flow Management. Data Center

Benefits of. Air Flow Management. Data Center Benefits of Passive Air Flow Management in the Data Center Learning Objectives At the end of this program, participants will be able to: Readily identify if opportunities i where networking equipment

More information

Storage Solutions. Maximize Storage & Optimize Space

Storage Solutions. Maximize Storage & Optimize Space Storage Solutions Maximize Storage & Optimize Space Your Files Are Important With the cost and availability of office space at a premium, space utilization is key. An end-tab color-coded filing system

More information

Integrated Data Center Infrastructure Optimizes Power, Space and Cooling While Reducing Complexity

Integrated Data Center Infrastructure Optimizes Power, Space and Cooling While Reducing Complexity white paper 1 Integrated Data Center Infrastructure Optimizes Power, Space and Cooling While Reducing Complexity THE GROWING COMPLEXITY OF THE DATA CENTER makes it difficult to find and retain people with

More information

Data centre experts. Advanced power protection for data centres

Data centre experts. Advanced power protection for data centres Data centre experts Advanced power protection for data centres A robust power protection strategy is critical to successful data centre operations. Uninterruptible Power Supplies Limited (UPSL), a Kohler

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

DATA CENTER SOLUTIONS GUIDE

DATA CENTER SOLUTIONS GUIDE DATA CENTER SOLUTIONS GUIDE designed to be better. Power Cabinets Racks Pathways Aisle Containment Connectivity and Cabling RACKS AND CABINETS Legrand s cabinets and racks, designed for all your network

More information

Strategies for Deploying Blade Servers in Existing Data Centers

Strategies for Deploying Blade Servers in Existing Data Centers Strategies for Deploying Blade Servers in Existing Data Centers By Neil Rasmussen White Paper #125 Revision 1 Executive Summary When blade servers are densely packed, they can exceed the power and cooling

More information

How To Make A Data Center More Efficient

How To Make A Data Center More Efficient IT Solutions for Business-Critical Continuity Emerson Network Power Data Center Infrastructure Many Needs. One Source. Emerson Network Power, a division of Emerson Electric Co., is a global company that

More information

Optimizing your Infrastructure for Cloud Computing

Optimizing your Infrastructure for Cloud Computing Optimizing your Infrastructure for Cloud Computing Best practices for managing a cloud IT environment By Chris Loeffler Data Center Applications Manager, Distributed Power Solutions Eaton Corporation Executive

More information