High Performance (Copper) Cable Technology
|
|
|
- Joanna Boone
- 10 years ago
- Views:
Transcription
1 High Performance (Copper) Cable Technology Jay Diepenbrock October, 2013 September, 2013 IEEE 1
2 Outline What and where are High Performance cables? Cable types Differential links Cable assembly construction Cables and EMI Cable EMI mitigation Measuring EMC properties of Cables References September,
3 High Performance Cables Where? Everywhere What? Big Data servers, networks Ethernet, InfiniBand, SAS, PCI-Express PCs SAS, USB 3.0 Multimedia devices USB 3.0, Thunderbolt TVs, entertainment Coax (!), HDMI September,
4 Aggregate throughput, Gb/s High Performance Cables I/O Interface Data Rates PCI-Express Gen. 1 PCI-Express Gen Year PCI-Express Gen. 3 SAS 2.1 SAS 3 S-ATA 1.0 S-ATA 2.0 S-ATA 3.0 InfiniBand SDR InfiniBand DDR InfiniBand QDR InfiniBand FDR InfiniBand EDR Thunderbolt USB 1.1 USB 2 USB 3.0 HDMI 1.0 HDMI 1.3 HDMI 1.4 HDMI 2.0 Ethernet (100 Mb) Ethernet (Gb) Ethernet (802.3ba) Ethernet (SFF-8431) Ethernet (802.3bj) September,
5 Cable types Passive or Active Copper or Fiber Bulk wire construction Shielded or not Single or multiconductor + Ground Round or ribbonized Flex Laminated coax Hybrid misc. mixes (signals + power, etc.) Connectors Coax (F, SMA, N) Direct attach multi-pin Paddle card (soldered) multi-pin Backplane style Pluggable transceiver September,
6 Cable Types connector Cu bulk wire connector Passive Half active (Tx or Rx end) connector Cu bulk wire connector connector Cu bulk wire connector Full active connector Optical fiber connector Active Optical = electrical amp or eq. = O/E or E/O converter September,
7 Single-conductor Cable (coax) Construction Many sizes, materials Majority are 50 or 75 Ohms Single signal conductor Dielectric PE, PTFE, etc. Shield (braid or foil+braid) Jacket D dielectric Z 0 = 60 e r D d Applications TV, radio broadcasting Cable TV Commercial, amateur radio Military Cell phones Anything RF (audio?) Center Cond. d shield September,
8 Differential Pair Cables Majority of high speed interfaces now differential On chip, between functional islands Memory On-card I/O Why Differential signaling? Higher system noise margin Power supply voltages decreasing -> lower voltage swing Lower noise immunity (crosstalk) Reduced EMI September,
9 Differential Pair Bulk wire Construction Two signal lines, many geometries Typically 100 Ohms impedance Twisted or parallel pair Dielectric air, PE, PTFE, etc. Shielded (braid or foil+braid) or not Jacketed or not Applications Networking ( Category ) UTP, STP HPC, Supercomputing, I/O (Fibre Channel, PCI-e, SAS, S-ATA, InfiniBand, Ethernet, etc.) Computer storage SAS, S-ATA, USB Consumer HDMI, USB, Thunderbolt September,
10 Twisted Pair bulk wire Inexpensive Various performance grades ( Category 5, 5e, 6, 6a, 7 cables) Some shielded Can be field terminated Susceptible to crosstalk Application Lane speed Ethernet Mb/s # lanes (pairs) Cable Type 4 Cat. 3, 5, 5e UTP* Ethernet 10 Gb/s 4 Cat. 6a STP PCI-e Gb/s FC, Enet, IB, * 2-32 SPP 2-25 Gb/s 2-24 SPP September,
11 Shielded Parallel Pair ( Twinax ) bulk wire Higher performance than TP Individually Shielded Pairs Various dielectrics - dielectric PE, PTFE, etc. Foil and/or bulk braid shield Outer jacket per application Flammability Abrasion, chemical resistance Applications - I/O, networking (FC, PCI-e, SAS, S-ATA, InfiniBand, Ethernet, etc.) Bulk shield s D d Drain wire September,
12 Shielded Parallel Pair ( Twinax ) Advantages Good performance Low crosstalk Pitfalls Symmetry important Non-uniform materials Geometric structure Common Mode generation Skew System asymmetries Manufacturing good bad September,
13 Shielded Parallel Pair shield topology 0 EXD versus Standard Spiral Shield 24 AWG 100 Ohm EXD Spiral 10 meter data, fixture not removed Longitudinal shield -30 SDD21 db / 10 meter thru fixture EXD 1 EXD 2 EXD 3 EXD Optimized for High Frequency 1 Optimized for High Frequency 2 Optimized for High Frequency 3 Optimized for High Frequency 4 Spiral shield Frequency MHz September,
14 Quad Construction Four signal lines (two pairs), but smaller Dielectric PE, PTFE Unshielded quad Bulk shield Jacket Applications HPC, Supercomputing Limited usage Expensive, hard to make orthogonality critical to CM, xtalk perf. Hard to terminate shield September,
15 Connectors SFF-8487 internal mini SAS SFF-8088 external mini SAS SFF-8470 SAS HDMI 7-pin Serial ATA right-angle 7-pin Serial ATA straight SFF-8482 SAS 29 pin w /power September,
16 Connectors PCI-Express x16 (QSFP) SFF-8038 (SFP+) September,
17 Tear-down QSFP (SFF-8088) Screw Cover Shell Spring Latch Base Raw Cable Spacer Insert Molding PCBA Cover September,
18 Wire termination QSFP SFF-8088 (12X InfiniBand) September,
19 Differential Links Each signal transmitted by a pair of conductors, driven Signal conductors Dielectric 180 degrees out of phase + - card wire cable + - Considerations: greater common mode noise immunity than single-ended less EMI radiation than single-ended must consider and measure differential quantities analysis, simulation methods test equipment, fixtures additional propagation modes are possible Drain wire Foil shield September,
20 Differential Impedance Modes" are now possible Case 1 L, C, Z L, C, Z common mode C 11 C 12 C 21 C 22 L 11 L 12 L 21 L 22 L/C September,
21 Differential Impedance Modes" are now possible Case 1 L, C, Z L, C, Z common mode Case 2 L, C, Z L, C, Z differential mode the modes have different impedances, and different propagation delays! C 11 C 12 L 11 L 12 C 21 C 22 L 21 L 22 It's still L/C, but now C= and L= September,
22 Differential Measurements Options Make multiple single-ended measurements and do the math yourself Z 11 Z 12 Z 22 see Carey, Scott, and Weeks: "Characterization of Multiple Parallel Transmission Lines," IEEE Trans. Instr. and Meas., Sept Buy differential test equipment, build differential fixtures Differential TDR - measure M1=C1-C2 Four port VNA or two port with external test set - measure sdd21, not s21, and sdd11, not s11 Provides additional information over use of baluns (no common mode data) September,
23 Differential Pair Skew Two types: in-pair (between legs of pair) Due to difference in propagation delay between legs of pair Manifested as "excess attenuation" Spec. limits pretty tight - causes differential imbalance, and can cause EMI problems due to common mode energy not uniform with length! pair to pair (between pairs) difference in propagation delay between pairs modern interfaces relatively insensitive to it (500 ps limit) - it's corrected in the design September,
24 Skew September,
25 Skew Small amounts of skew create significant common mode noise As little as 1% of bit width for skew can have significant EMI effects As little as 10% of bit width skew creates CM signal of equivalent amplitude to initial signals September,
26 Skew 0.6 Individual Channels of Differential Signal with Skew 2 Gb/s with 50 ps Rise and Fall Time (+/- 1.0 volts) Voltage Channel 1 No Skew 10 ps 20 ps 50 ps 100 ps 150 ps 200 ps E E E E E E-09 Time (seconds) September,
27 Skew Common Mode Voltage on Differential Pair Due to In-Pair Skew 2 Gb/s with 50 ps Rise and Fall Time (+/- 1.0 volts) Amplitude (volts) ps 20 ps 50 ps 100 ps 150 ps 200 ps E E E E E E E E E E-09 Time (seconds) September,
28 Rise/fall time mismatch Small amounts of mismatch create significant CM noise Not as significant as skew, but harder to control! Telltale is significant 2 nd harmonic content September,
29 Rise/fall time mismatch Example of Effect for Differential Signal with Rise/Fall Time Mismatch 2 Gb/s Square Wave (Rise/Fall = 50 & 100 ps) Channel 1 Channel 2 T/R=50/100ps 0.2 Voltage E E E E E E E E E E E-09 Time (Seconds) September,
30 Rise/fall time mismatch Common Mode Voltage on Differential Pair Due to Rise/Fall Time Mismatch 2 Gb/s with Differential Signal +/- 1.0 Volts T/R=50/100ps T/R=50/150ps T/R=50/200ps Level (volts) E-10 1E E-09 2E E-09 3E E-09 4E E-09 5E-09 Time (seconds) September,
31 Eye opening and Jitter Measures time domain performance of link Measured using PRBS or application-specific data pattern (e. g., CJTPAT) Eye opening - vertical "black space" in middle of many overlaid bits minimum opening needed for receiver to distinguish between "1" and "0" Jitter - horizontal width of zero crossing of overlaid waveforms eye opening jitter September,
32 Eye Opening and Jitter test setup Pattern or BERT Gen. Sampling or real-time oscilloscope Clock PRBS7, 9,..31 pattern Vout ~= 1 Vpp Trise ~= 30 ps xx Gb/s Color-graded display Infinite persistence x Histogram hits Asynch. Crosstalk Source Test card Cable Test card (terminate unused ports with 50 Ohms to Ground) September,
33 Sources of EMI in Cables Skew in system coupled to cable shield, due to Asymmetric differential pairs Unequal rise/fall time of signals Common mode in signals Cable construction Common mode conversion in bulk wire Poor connection from Chassis to Cable plug backshell Leaky backshell Skew in plug/paddle card/bulk wire Poorly shielded bulk wire September,
34 Common mode conversion September,
35 Cable Assembly Construction Influence on EMC Shielding Pair shields foil in or out? Shielded or not? Drain wire handling Bulk shield Foil (high freq.) Braid (low freq.) shield coverage (typ %), weave angle, etc. Backshell design Seams, leakage potential Latches, jack screws Grounding Backshell-chassis connection springs, gaskets, drain wires Don t forget the system influence! In-pair skew Mismatched rise/fall tmes Common mode September,
36 Cable EMI sources HDMI cable shield connection From Bergey and Altland, EMI Shielding of Cable Assemblies, DesignCon 2008 September,
37 Cable EMI sources USB cable shield connection (or not!) From Bergey and Altland, EMI Shielding of Cable Assemblies, DesignCon 2008 September,
38 Cable EMI sources From Bergey and Altland, EMI Shielding of Cable Assemblies, DesignCon 2008 September,
39 Measuring Cable EMI Key parameters Transfer Impedance Shielding Effectiveness Measurement methods EM (CISPR 22) semi-anechoic chamber Tube fixture (IEC ) Measures transfer impedance Max. frequency ~1 GHz Reverb chamber (no standard yet) Measures shielding effectiveness Usable ~300 MHz 20 GHz September,
40 Tube Fixture September,
41 Tube Fixture Sample Results September,
42 Reverb Chamber Closed, conductive-walled room Usable frequency range ~300 MHz-20 GHz, depending on room size and antennae used Don t dampen resonance, celebrate it! CUT is driven with differential or common mode signal, radiated energy is measured No system hardware required Tuner used to stir resonances, either stepped or continuously from external controller Much work on reverb chambers at OK State Univ. (C. Bunting, et. al.) September,
43 Reverb Chamber September,
44 Reverb Chamber Measurement Antennas Tuner CUT Stepper motor CUT support (non-conductive) September,
45 September,
46 EMI Mitigation in Cables Many paths to EMC cleanliness Reduce system in-pair skew Match signal rise/fall times Reduce common mode energy coupling to cable shield Improve cable shield connection to cable backshell Reduce connection inductance Better shield coverage Utilize absorbing material in cable jacket Utilize Band Gap devices on host card September,
47 EMI Absorbing Material Available from ARC Technologies, Inc. for extrusion in cable jacket Molded enclosures (replace metal can) Covers over connectors Frequency selective suppression range depends on formula used Doesn t need to be used on whole cable just ends are enough September,
48 EMI Absorbing Material Motivation - Eliminate Ferrite Cores on Cables September,
49 EMI Absorbing Material Ethernet Cable Emission Reduction (When Drive Signal at Same End of Cable) ARC Lossy Material Covers Partial Length Reduction in Emissions (db) Ethernet Sample #1 w/ 11" Covered Ethernet Sample #1 w/ 23" Covered Ethernet Sample #1 w/ 37" Covered Ethernet Sample #1 Full Cable Covered E E E E E E E E E E E+10 Frequency (Hz) September,
50 References Diepenbrock, J.: Measurement and Analysis of Shielding Effectiveness and Transfer Impedance of High Speed Data Cables, DesignCon 2012 Archambeault, B., Connor, S., Diepenbrock, J., and Knight, A.: Developing Limits for Common Mode Noise on High Speed Differential Signals, DesignCon 2011 Hill. D.: Electromagnetic Theory of Reverberation Chambers, Natl. Inst. of Standards and Technology Tech Note 1506, 1998 Vignesh Rajamani, Charles F. Bunting and James C. West, Calibration of a Numerically Modeled Reverberation Chamber, IEEE Symposium on Electromagnetic Compatibility 2009 Archambeault, B., Chikando, E., Connor, S., and Diepenbrock, J.: High Speed Cables with Lossy Material Coating, IEEE 2010 Symposium on Electromagnetic Compatibility 2010 September,
51 Standards Other References Code of Federal Regulations Title 47, Telecommunications, part 15 (US) EN 55022, Information Technology Equipment Radio Disturbance Characteristics Limits and Methods of Measurement (Europe) ANSI/EIA/ECA A EMI Shielding Effectiveness of Electrical Connectors IEC Reverb chamber test methods IEC Screening attenuation measurement by the reverberation chamber method IEC Transfer impedance and screening, tube in tube method IEC Coupling attenuation of screened balanced cables, triaxial method IEEE 802 InfiniBand Specification, volume 2 PCI-Express Cabling Specification Other Agilent Technologies: Understanding the Fundamental Principles of Vector Network Analysis," AN , available at Bogatin, E: "Differential Impedance Finally Made Simple, available at Carey, Scott, and Weeks: "Characterization of Multiple Parallel Transmission Lines," IEEE Trans. Instr. and Meas., Sept Deutsch, A., "Electrical Characteristics of Interconnections for High-Performance Systems," IEEE Proceedings vol. 86 No. 2, Feb September,
52 Conferences DesignCon February, in Santa Clara, CA IEEE Electrical Performance of Electronic Packaging (EPEP) IEEE EMC Symposium (EMCS) in Raleigh, NC in August, 2014 Embedded SI conference IEEE ECTC, ED, ISSCC IEEE SPI workshop (Europe) 10/30/2013 IEEE 52
Managing Connector and Cable Assembly Performance for USB SuperSpeed
Whitepaper Managing Connector and Cable Assembly Performance for USB SuperSpeed Revision 1.0 February 1, 2013 Abstract USB 3.0 connector and cable assembly performance can have a significant impact on
Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness
Shielding Effectiveness Test Method Harbour s LL, SB, and SS Coaxial Cables Designs for Improved Shielding Effectiveness Harbour Industries 4744 Shelburne Road Shelburne Vermont 05482 USA 802-985-3311
Direct Attach Cable with Micro Coaxial Wire for Data Center
FEATURED TOPIC Direct Attach Cable with Micro Coaxial Wire for Data Center Yasuhiro MAEDA*, Kensaku SHIMADA, Yuki ISOYA, Tatsunori HAYASHISHITA and Michiko HARUMOTO ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
EMC countermeasures for High-Speed Differential Interfaces
TDK EMC Technology Practice Section EMC countermeasures for High-Speed Differential Interfaces How Do Common Mode Filters Suppress EMI in Differential Transmission Circuits? TDK Corporation Application
with Component Rating A Simple Perspective
Cat-6A UTP and Shielded with Component Rating A Simple Perspective Asef Baddar RCDD, DCD Sr. Technical Manager Leviton Middle East Category Specifications Agenda Terminology International & North America
The ABC of Direct Attach Cables
The ABC of Direct Attach Cables Thomas Ko, RCDD Product Manager TE Connectivity Network Speed and Technology 10/40/100 Gbps the transition is occurring right now What are Customers Saying about their 10/40/100
Networks. The two main network types are: Peer networks
Networks Networking is all about sharing information and resources. Computers connected to a network can avail of many facilities not available to standalone computers: Share a printer or a plotter among
MICRO SFP+ CONNECTOR & CABLE ASSEMBLY
MICRO SFP+ CONNECTOR & CABLE ASSEMBLY micro SFP+ Connector and Cable Assembly TE Connectivity s (TE) micro SFP+ connector and cable assembly empower you to dream big when designing your communication system.
Subject: Glenair MIL-PRF 24758 Conduit Surface Transfer Impedance Test
Lothar O. Hoeft, Ph.D. Consultant, Electromagnetic Effects 5012 San Pedro Ct., NE Albuquerque, New Mexico 87109-2515 Phone: (505)-889-9705 E-mail: [email protected] 1 February 24, 2006 Subject: Glenair
Understanding Shielded Cable
Understanding Shielded Cable Industrial applications such as the factory floor are typically electrically noisy environments. Electrical noise, either radiated or conducted as electromagnetic interference
High-Definition Multimedia Interface (HDMI) Source/Sink Impedance Compliance Test Test Solution Overview Using the E5071C ENA Option TDR
High-Definition Multimedia Interface (HDMI) Source/Sink Impedance Compliance Test Using the E5071C ENA Option TDR Keysight Technologies Component Test Division Revision 01.10 2015/03/12 (YS) Reference
Solving Signal Problems Effective shielding is key to enhancing the reliability and performance of broadcast cables.
Solving Signal Problems Effective shielding is key to enhancing the reliability and performance of broadcast cables. by Marty Van Der Burgt Belden Article for Broadcast Engineering There is perhaps no
Transmission of High-Speed Serial Signals Over Common Cable Media
Transmission of High-Speed Serial February 0 Introduction Technical Note TN066 Designers are often faced with moving serial data from one location to another, over moderate distances, and in the most efficient
USB 3.0 INTERNAL CONNECTOR AND CABLE SPECIFICATION
USB 3.0 INTERNAL CONNECTOR AND CABLE SPECIFICATION Revision 1.0 August 20, 2010 2007-2010 Intel Corporation All rights reserved. Legal Disclaimers THIS SPECIFICATION IS PROVIDED AS IS WITH NO WARRANTIES
Annex 113A Description of cable clamp and test setup. (informative) 113A.1 Overview
Annex 113A Description of cable clamp and test setup (informative) 113A.1 Overview This annex describes an example of a cable clamp and a a representative methodology that should be used in common-mode
Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology
Antennas for EMC Testing Zhong Chen ETS-Lindgren 1301 Arrow Point Drive Cedar Park, TX 78613 [email protected] Outline EMC Terms and Definitions Typical EMC Antennas Calibration of EMC Antennas
Nexus Technology Review -- Exhibit A
Nexus Technology Review -- Exhibit A Background A. Types of DSL Lines DSL comes in many flavors: ADSL, ADSL2, ADSL2+, VDSL and VDSL2. Each DSL variant respectively operates up a higher frequency level.
An Ethernet Cable Discharge Event (CDE) Test and Measurement System
An Ethernet Cable Discharge Event (CDE) Test and Measurement System Wei Huang, Jerry Tichenor ESDEMC Technology LLC Rolla, MO, USA [email protected] Abstract A Cable Discharge Event (CDE) is an electrostatic
Twinax Intra Pair Skew Comparison Report Various Lengths and Competitors Tested
Twinax Intra Pair Skew Comparison Report Various Lengths and Competitors Tested 4.5 Average All Lengths Intra-Pair Skew Samtec vs. Competitors 4.0 3.5 Average pico-seconds 3.0 2.5 2.0 1.5 1.0 Competitor
Grounding Demystified
Grounding Demystified 3-1 Importance Of Grounding Techniques 45 40 35 30 25 20 15 10 5 0 Grounding 42% Case 22% Cable 18% Percent Used Filter 12% PCB 6% Grounding 42% Case Shield 22% Cable Shielding 18%
Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance
Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance Page 1 Agenda Introduction PCIe 2.0 changes from 1.0a/1.1 Spec 5GT/s Challenges Error Correction Techniques Test tool
Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B
CSE 3461 / 5461: Computer Networking & Internet Technologies Data Transmission Presentation B Kannan Srinivasan 08/30/2012 Data Communications Model Figure 1.2 Studying Assignment: 3.1-3.4, 4.1 Presentation
Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants www.hottconsultants.com
Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants www.hottconsultants.com Workbench EMC measurements are simple, inexpensive precompliance tests that a product designer can perform early
Western Cable Corporation
AUDIO/ CONTROL CABLE Audio / Control Multipair Unshielded Muticonductor Foil Shield Multipair Foil Shield Individual Multiconductor Braided Shield Composite Audio Cable Multipair Shielded & Unshielded
Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8
Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC by Paul Kish NORDX/CDT Chair TIA TR 41.8 Outline Market trends Standards development where we were where we are where we are going Beyond Category
Category 8 Cable Transmission Measurements Comparative Study between 4-port single wire measurements and 2-port balun measurements
Category 8 Cable Transmission Measurements Comparative Study between 4-port single wire measurements and 2-port balun measurements Stefan Estevanovich Rafael Herrera, Nadim Kafati Hitachi Cable USA NDC
Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011
Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications June 2011 Application Note Common mode chokes provide an effective EMI filtering solution for Ethernet transformer applications.
Radiated Emission and Susceptibility
Radiated Emission and Susceptibility Tzong-Lin Wu, Ph.D. EMC Lab Department of Electrical Engineering National Taiwan University Differential-Mode v.s. Common-mode Currents 1 Differential-Mode v.s. Common-mode
High Speed Cables for Enterprise Data Solutions Business Unit Telecommunication Systems
High Speed Cables for Enterprise Data Solutions Business Unit Telecommunication Systems 2 The LEONI Group Cable competence for different industrial markets LEONI is a leading supplier of cable systems
Comparison of Vector Network Analyzer and TDA Systems IConnect Generated S-Parameters
Comparison of Vector Network Analyzer and TDA Systems IConnect Generated S-Parameters Purpose: This technical note presents single-ended insertion loss ( SE IL) and return loss ( SE RL) data generated
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling
Experimental Analysis of Common Mode Currents on Fibre Channel Cable Shields due to Skew Imbalance of Differential Signals Operating at 1.
Experimental Analysis of Common Mode Currents on Fibre Channel Cable Shields due to Skew Imbalance of Differential Signals Operating at 1.06 Gb/s James L. Knighten Joseph T. (Ted) DiBene II Norman W. Smith
PCb Cable mount twinax. ConneCtorS
PCb Cable mount twinax ConneCtorS technical CharaCteriStiCS SPeCiFiCationS temperature rating: -55 C to + 125 C Corrosion: MIL-STD-202 Method 101, Test Condition B Shock: MIL-STD-202 Method 213, Test Condition
WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications
WHITEPAPER Cable and Connector for Hiperface dsl motor drive applications information for cable manufacturers Version 02 Content Information for cable manufacturers...3 Communication...3 Crosstalk & shielding...3
Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable
Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable June 10, 2010 Contributors: Yinglin (Frank) Yang CommScope, Inc. Charles Seifert Ixia Ethernet Alliance 3855 SW 153 rd
This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:
UTP Technology In the late 1970s, unshielded twisted pair (UTP) cabling originated in the computer industry as a means of transmitting digital data over computer networks. This cable was designed to be
AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation
AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation Abstract EMC compatibility is becoming a key design
Quick Reference Guide High Speed Input/Output Solutions
Quick Reference Guide The pluggable I/O interface offers significant advantages as a high speed I/O interconnect. With a standard equipment I/O interface and the flexibility of pluggable modules come the
10/100BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 100 Mbps Fast Ethernet. Features. Application
Features Compliant with IEEE 802.3u standard Link distance at 100Mbps: up to 100m per IEEE802.3 EEPROM with serial ID functionality Detailed product information in EEPROM Industry standard small form pluggable
Amphenol. High Speed Solutions CABLE ASSEMBLIES
Amphenol High Speed Solutions CABLE ASSEMBLIES amphenol aerospace located in sidney, ny 1 One of the largest manufacturers of interconnect products in the world. WE design manufacture market INTERCONNECT
Eatman Associates 2014 Rockwall TX 800-388-4036 rev. October 1, 2014. Striplines and Microstrips (PCB Transmission Lines)
Eatman Associates 2014 Rockwall TX 800-388-4036 rev. October 1, 2014 Striplines and Microstrips (PCB Transmission Lines) Disclaimer: This presentation is merely a compilation of information from public
KVPX CONNECTOR SERIES HIGH SPEED SIGNAL INTEGRITY REPORT
KVPX CONNECTOR SERIES HIGH SPEED SIGNAL INTEGRITY REPORT CONTENTS 1 2 3 3 3 3 3 4 4 4 5 6 7 HIGH SPEED DATA TRANSFER Market Drivers for High Speed Signal Integrity Key Characteristics Impedance Matching
75 Ω Transmission System
NRAO NTC-DSL Laboratory Report Dynamic Spectroscopy Laboratory Report Series Report 03 September, 2006 75 Ω Transmission System Chaitali R. Parashare Department of Electrical and Computer Engineering,
Network Design. Yiannos Mylonas
Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which
Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content
Charged cable event David Pommerenke, [email protected], 916 785 4550 Last update: Feb.23, 2001 Content Goal Energy sources, which may lead to CDE. Complexity of the different discharge modes. Possible
1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING
1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L APPLICATION NOTE AN-357 1.0 INTRODUCTION In today's highly competitive market, high quality of service, QOS, and reliability is
Características. Starligh SA 9 de julio 1595 Córdoba Argentina - 0351-4809210 / 4119600
Balun Activo - BALUN_ACT Características Single Channel Active Video Transmitter Full-motion color video signal up to 3900ft(1200m) via UTP cat5e/6 NTSC, PAL & SECAM video format compatible Real-time transmission
10/100/1000BASE-T SFP Transceiver
10/100/1000BASE-T SFP Transceiver Features Support 10/100/1000BASE-T operation in host systems with SGMII interface Up to 1.25Gbps bi-direction data links Hot-pluggable SFP footprint Fully metallic enclosure
Feasibility of 25 Gb/s Serial Transmission Over Copper Cable Assemblies
DesignCon Feasibility of 5 Gb/s Serial Transmission Over Copper Cable Assemblies Vittal Balasubramanian, FCI USA, LLC [email protected] Stephen B. Smith, FCI USA, LLC [email protected]
Chapter 4 Connecting to the Internet through an ISP
Chapter 4 Connecting to the Internet through an ISP 1. According to Cisco what two things are essential to gaining access to the internet? a. ISPs are essential to gaining access to the Internet. b. No
Oscilloscope Bandwidth Requirements for Emerging Serial Data Interfaces
Oscilloscope Bandwidth Requirements for Emerging Serial Data Interfaces Page 1 What best determines bandwidth requirements? 5 th harmonic? Or spectral content of the signal, which is related to rise time?
Data Communications Competence Center
Importance of Cable Balance For Improving Noise Susceptibility Data Communications Competence Center DCCC03101702 July 11, 2007 Summary In a study of category 5e and category 6 UTP cables, a strong correlation
HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks
HIGHSPEED ETHERNET THE NEED FOR SPEED Jim Duran, Product Manager - Americas WHITE PAPER Molex Premise Networks EXECUTIVE SUMMARY Over the years structured cabling systems have evolved significantly. This
Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.
Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip. Each dielectric configuration has different high-frequency characteristics. All configurations
8 Gbps CMOS interface for parallel fiber-optic interconnects
8 Gbps CMOS interface for parallel fiberoptic interconnects Barton Sano, Bindu Madhavan and A. F. J. Levi Department of Electrical Engineering University of Southern California Los Angeles, California
RoHS Compliant Copper Small Form Factor Pluggable (SFP) Transceiver for Gigabit Ethernet
RoHS Compliant Copper Small Form Factor Pluggable (SFP) Transceiver for Gigabit Ethernet Features Compatible with specifications for IEEE 802.3ab/Gigabit Ethernet Compliant with MSA specifications for
Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair
Presentation; Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair 5 th April 2010 Paul Mathews MInstSMM, CCNA, MIEEE Global Channel Manager Media Types Physical Layer Cabling;
The Bus (PCI and PCI-Express)
4 Jan, 2008 The Bus (PCI and PCI-Express) The CPU, memory, disks, and all the other devices in a computer have to be able to communicate and exchange data. The technology that connects them is called the
Ultra640 SCSI Measured Data from Cables & Backplanes
T10/01-224r0 Ultra640 SCSI Measured Data from Cables & Backplanes Russ Brown Maxtor Corporation Parallel SCSI Working Group 17 July 2001 Colorado Springs, CO Introduction The following presents some of
Cable Solutions for Servo and Variable Frequency Drives (VFD)
Cable Solutions for Servo and Variable Frequency Drives (VFD) Electric drive systems with continuous torque and speed control are widespread today. They allow an optimal adjustment of the drive with respect
SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03
SICK AG WHITEPAPER Cable and connector for HIPERFACE DSL motor drive applications Information for cable manufacturers Note-2_03 Juergen Funkhaenel Application Engineer at SICK STEGMANN GmbH Donaueschingen
A Study of RF Absorber for Anechoic Chambers Used in the Frequency Range for Power Line Communication System
538 Progress In Electromagnetics Research Symposium 2006, Cambridge, USA, March 26-29 A Study of RF Absorber for Anechoic Chambers Used in the Frequency Range for Power Line Communication System K. Shimada
An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware
for CAT 6A Connecting Hardware Written by: Antoine Pelletier Engineer, Global Cabling Products Intertek www.intertek-etlsemko.com 1-800-WORLDLAB Introduction The telecommunication industry recently achieved
PCB Radiation Mechanisms: Using Component-Level Measurements to
Radiation Directly from PCB Structures PCB Radiation Mechanisms: Using Component-Level Measurements to Determine System-Level Radiated Emissions Signal or component voltage appears between two good antenna
How to Choose the Right Cable Category
How to Choose the Right Cable Category Why do I need a different category of cable? Not too long ago, when local area networks were being designed, each work area outlet typically consisted of one Category
Coaxial Cables for Medium-Frequency Applications
Coaxial Cables for Medium-Frequency Applications Coaxial Cables for Medium-Frequency Applications Introduction Telecommunications technology is moving forward rapidly and the need for fast and reliable
Consulting. IEEE Joint Meeting Rockford, March 28, 2011 2011 ROY LEVENTHAL
EMI-EMC EMC Theory and Test Consulting IEEE Joint Meeting Rockford, March 28, 2011 2011 ROY LEVENTHAL http://www.semiconductorsimulation.com http://www.semiconductormodel.com [email protected] 847-590-9398
Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port
Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port This app note applies to the following Lantronix Products: WiPort BG WiPort NR MatchPort BG MatchPort AR XPort Direct+
Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR
Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR 1 Table of Contents 1. Revision History... 3 2. Purpose... 3 3. References...
1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver
1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver Features Up to 1.25Gb/s bi-directional data links Hot-pluggable SFP footprint TX Disable and RX Los/without Los function Fully metallic enclosure
Consideration of a high-capacity foil cable:
Consideration of a high-capacity foil cable: Newly discovered ancient knowledge. The old RF-developers already knew the benefits of longplanar lines and have been used (electronic) Eonen (times) thin flat
for Communication Systems Protection EMI CD-ROM INCLUDED
Krešimir Malarić EMI Protection for Communication Systems CD-ROM INCLUDED Contents Preface xiii CHAPTER 1 Communications Systems 1 1.1 Components of Communications Systems 1 1.2 Transmitter Systems 2 1.2.1
Computer buses and interfaces
FYS3240 PC-based instrumentation and microcontrollers Computer buses and interfaces Spring 2011 Lecture #5 Bekkeng 15.1.2011 The most common data acquisition buses available today Internal computer buses
For emission and immunity testing according to IEC 61000-4-20
EMC GTEM 500 Gtem Cell For emission and immunity testing according to IEC 61000-4-20 Theory of operation GTEM-cells (Giga-hertz Transversal Electro-Magnetic cells) are waveguide structures intended for
Zero-Variable Wireless Infrastructure Deployment. Datasheet. Models: BM2HP, BM5HP. Completely integrated Radio
Zero-Variable Wireless Infrastructure Deployment Models: BM2HP, BM5HP Completely integrated Radio Directly plugs into any Antenna that has a Type N female connector Robust Weatherproof Design Overview
Application Note. PCIEC-85 PCI Express Jumper. High Speed Designs in PCI Express Applications Generation 3-8.0 GT/s
PCIEC-85 PCI Express Jumper High Speed Designs in PCI Express Applications Generation 3-8.0 GT/s Copyrights and Trademarks Copyright 2015, Inc. COPYRIGHTS, TRADEMARKS, and PATENTS Final Inch is a trademark
LVDS Technology Solves Typical EMI Problems Associated with Cell Phone Cameras and Displays
AN-5059 Fairchild Semiconductor Application Note May 2005 Revised May 2005 LVDS Technology Solves Typical EMI Problems Associated with Cell Phone Cameras and Displays Differential technologies such as
EVOline Multimedia Modules
243 EVOline VGA cable EVOline DVI-A cable EVOline DVI-D cable EVOline HDMI cable Cable properties Flame retardant self extinguishing VW-1 Halogen free yes yes yes Colour Black Black Outer diameter 7,2
Jitter in PCIe application on embedded boards with PLL Zero delay Clock buffer
Jitter in PCIe application on embedded boards with PLL Zero delay Clock buffer Hermann Ruckerbauer EKH - EyeKnowHow 94469 Deggendorf, Germany [email protected] Agenda 1) PCI-Express Clocking
The DNA of Atlas Audio Interconnects & Cables. (Analogue, Digital, HDMI, and USB).
The DNA of Atlas Audio Interconnects & Cables. (Analogue, Digital, HDMI, and USB). October 2012 Why do some cables clearly sound better than others? To understand the philosophy behind the products of
UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS
Page 1 UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS By Henry Ott Consultants Livingston, NJ 07039 (973) 992-1793 www.hottconsultants.com [email protected] Page 2 THE BASIC
Uncompromising Integrity. Making 100Gb/s deployments as easy as 10Gb/s
Uncompromising Integrity Making 100Gb/s deployments as easy as 10Gb/s Supporting Data Rates up to 100Gb/s Mellanox 100Gb/s LinkX cables and transceivers make 100Gb/s deployments as easy as 10Gb/s. A wide
Chapter 1 // Computer Cables THE WORLD OF CABLES. delivery of stock goods in 24 hours. certified quality
THE WORLD OF CABLES 2012 // delivery of stock goods in 24 hours certified quality 9 own branches worldwide - global sourcing - local serving all services are online available since 42 years original ASSMANN
Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka
Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka What is a network? A computer network is two or more computers connected together using a telecommunication system for the purpose
Time and Frequency Domain Analysis for Right Angle Corners on Printed Circuit Board Traces
Time and Frequency Domain Analysis for Right Angle Corners on Printed Circuit Board Traces Mark I. Montrose Montrose Compliance Services 2353 Mission Glen Dr. Santa Clara, CA 95051-1214 Abstract: For years,
USB 3.1 Type-C and USB PD connectors
USB 3.1 Type-C and USB PD connectors Presentation Introduction Purpose USB Type-C connectors Supplement to the USB 3.1 and Power Delivery specification Define USB 3.1Type-C receptacle, plug and cable assembly
Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications
Page 1 of 8 Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications Contents Introduction Prerequisites Requirements Components Used Conventions Which Cable Do I Need? Ethernet Cabling Guidelines
PRODUCT SPECIFICATION
ipass TM / ipass+ TM 0.8 mm PITCH I/O CONNECTOR SYSTEM EXTERNAL ipass / ipass+ of TABLE OF CONTENTS.0 SCOPE... 3.0 PRODUCT DESCRIPTION... 3. PRODUCT NAME AND SERIES NUMBER(S)... 3. DIMENSION, MATERIALS,
Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.
Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist. Abstract. I have been asked to put together a detailed article on a SWR meter. In this article I will deal
Eye Doctor II Advanced Signal Integrity Tools
Eye Doctor II Advanced Signal Integrity Tools EYE DOCTOR II ADVANCED SIGNAL INTEGRITY TOOLS Key Features Eye Doctor II provides the channel emulation and de-embedding tools Adds precision to signal integrity
Designing the NEWCARD Connector Interface to Extend PCI Express Serial Architecture to the PC Card Modular Form Factor
Designing the NEWCARD Connector Interface to Extend PCI Express Serial Architecture to the PC Card Modular Form Factor Abstract This paper provides information about the NEWCARD connector and board design
Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.
1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking
Extending Rigid-Flex Printed Circuits to RF Frequencies
Extending -Flex Printed Circuits to RF Frequencies Robert Larmouth Teledyne Electronic Technologies 110 Lowell Rd., Hudson, NH 03051 (603) 889-6191 Gerald Schaffner Schaffner Consulting 10325 Caminito
How To Get A Better Signal From A Fiber To A Coax Cable
Gigabit Transmission What s the Limit? Fanny Mlinarsky Page 1 What s the Limit? Speed Faster higher frequency higher attenuation less headroom Distance Longer higher attenuation more jitter less headroom
PCI Express and Storage. Ron Emerick, Sun Microsystems
Ron Emerick, Sun Microsystems SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies and individuals may use this material in presentations and literature
PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based
PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based Description Silicom s quad port Copper 10 Gigabit Ethernet Bypass server adapter is a PCI-Express X8 network interface
Siemens Energy & Automation. structured. WIRING Product Training Series: Advanced Video Session 3
s structured WIRING Product Training Series: Advanced Video Session 3 1 Table of Contents This presentation will give you a closer look at Video in Structured Wiring applications. The following Areas will
6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding
circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),