SAIL Small Animal Imaging Lab
|
|
|
- Lynne Fowler
- 10 years ago
- Views:
Transcription
1 Prof. T. Helbich/PD. P. Brader SAIL Small Animal Imaging Lab
2 Small Animal Imaging - Warum? Identifikation und Entwicklung von neuen Diagnostika (Kontrastmitteln/Tracern),Therapeutika und deren Kombination (Theranostika) Longitundinale Studien in ausreichenden Fallzahl Studien an genetically engineered Tiermodellen (Transgenic, Knock-out Mäusen) Probleme mit Tieren im klinischen Krankenhausbereich Nur eingeschränkte Verfügbarkeit klinischer Scanner (Abends, Nachts oder Wochenende)
3 Small Animal Imaging - Warum? Clinical PET Scanner Resolution: 6 mm FWHM Small-animal PET Scanner Resolution: 2 mm FWHM Tumor Xenograft = Viable rim + Necrotic core Whole-Body Mouse Images Coronal sections
4 Kooperationspartner
5 Plan: SAIL im AKH-Bauteil 24, Ebene1 CeMM Anna Spiegel FG
6 Modalitäten KOMBINATION: HYBRID-SYSTEME
7 Micro PET / CT Vordere Abdeckung entfernt Δθ 1º Detector Phosphor + CCD X-ray tube 90 μm ~5-10 min/tier
8 Quantitative MicroCT Cephalo- Caudal dimension Ventro-Dorsal dimension
9 MicroPET / CT LSO single crystal - 8 pro Ring bis zu 3 Ringe FOV: 8 cm Durchmesser X 15 cm Länge Maus Ratte FWHM 1.5 mm 2.2 mm
10 MicroPET Cranial MIBG 2h Axial Coronal Sagittal Throid Gland 3.0 % ID / g Lateral Tumor Lung Tumor Liver Medial Caudal FDG 1h Gut Heart 0.0 Brain 7.0 % ID / g %ID/g B Tumor Values GLV-1h99 48h n=5 GLV-1h99 72h GLV-1h68 48h No Virus n=5 n=3 n=3 Heart Kidney 0.0 Courtesy of Peter Brader. Brader et al. Clin Cancer Res. 2009;15: h 2h 4h 12h 24h 48h
11 MicroPET / CT M M L LT M LT LT L Riedl et al. Radiology. 2008;248:
12 Optische Bildgebung Bio-Luminescence Fluorescence Requires genetic transduction - Luciferase gene - of tracked cells Conventional reflectance illumination Fluorophore source Transillumination Light originates in labeled cell Light originates exogeneously
13 Optische Bildgebung Fluoreszenz RFP GFP mplum food autofl. Multispektrale Fluoreszenzbildgebung GFP RFP Standard fluorescent image Unmixed Unmixed GFP mplum RFP mplum Unmixed Normalized Spectra Unmixed composite - Maestro Courtesy of Pat Zanzonic, MSKCC.
14 Ultraschall Spatial resolution: < 100 μ Motor-driven logitudinal motion for 3D imaging Heated stage w/ EKG sensors
15 Ultraschall
16 MicroMRT (>11 Tesla) e f cranial lateral g h L R L R i j L R L R
17 MR Portfolio
18 Kontakt: Medical Imaging Plattform /imaging
Data. microcat +SPECT
Data microcat +SPECT microcat at a Glance Designed to meet the throughput, resolution and image quality requirements of academic and pharmaceutical research, the Siemens microcat sets the standard for
Laue lens for Nuclear Medicine
Laue lens for Nuclear Medicine PhD in Physics Gianfranco Paternò Ferrara, 6-11-013 Supervisor: prof. Vincenzo Guidi Sensors and Semiconductors Lab, Department of Physics and Earth Science, University of
Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III. Prof. Dr. Lothar Schad.
1 12/9/2008 Page 1 Master s Program in Medical Physics Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III Chair in Faculty of Medicine Mannheim University of Heidelberg Theodor-Kutzer-Ufer
Multispectral Optoacoustic Tomography (MSOT): The next generation in molecular imaging.
INTRODUCING: THE MSOT SCANNER FAMILY. Multispectral Optoacoustic Tomography (MSOT): The next generation in molecular imaging. Optoacoustic scanner for small animal imaging Anatomical, functional and molecular
Case Report: Whole-body Oncologic Imaging with syngo TimCT
Case Report: Whole-body Oncologic Imaging with syngo TimCT Eric Hatfield, M.D. 1 ; Agus Priatna, Ph.D. 2 ; John Kotyk, Ph.D. 1 ; Benjamin Tan, M.D. 1 ; Alto Stemmer 3 ; Stephan Kannengiesser, Ph.D. 3 ;
PET/CT: Basic Principles, Applications in Oncology
PET/CT: Basic Principles, Applications in Oncology Mabel Djang, HMS III Overview PET Basics and Limitations PET/CT - Advantages and Limitations Applications of PET/CT in oncology Summary 2 Principles of
Next Generation Small Animal PET Technology
G4 PET/X-ray P R O D U C T N O T E Pre-clinical in vivo Imaging Key Benefits: High performance, ultra-sensitive PET technology designed for pre-clinical imaging 3D PET and X-ray whole body images Purpose
Lung Cancer: Diagnosis, Staging and Treatment
PATIENT EDUCATION patienteducation.osumc.edu Lung Cancer: Diagnosis, Staging and Treatment Cancer begins in our cells. Cells are the building blocks of our tissues. Tissues make up the organs of the body.
High-resolution bio-imaging with liquid-metal-jet x-ray sources
High-resolution bio-imaging with liquid-metal-jet x-ray sources Hans Hertz Dept. of Applied Physics Royal Inst. of Technol. (KTH), Stockholm KTH: Ulf Lundström, Daniel Larsson, Anna Burvall, Tunhe Zou,
Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity
Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Innovation with Integrity Micro-CT 3D Microscopy Using Micro-CT for SEM Micro-CT for SEM
Sensitivity and Selectivity in Optical Spectroscopy and Imaging: A Molecular Approach
Sensitivity and Selectivity in Optical Spectroscopy and Imaging: A Molecular Approach Process Analysis & Technology Prof. Dr. R. W. Kessler STZ Technology Process Control and Data Analysis 72762 Reutlingen,
QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET
Centers for Quantitative Imaging Excellence (CQIE) LEARNING MODULE QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET American College of Radiology Clinical Research Center v.1 Centers for Quantitative
Global Business Unit Address. Siemens Medical Solutions USA, Inc. 2501 N. Barrington Road Hoffman Estates, IL 60192-5203. Telephone: +1847 304 7700
Trademarks and service marks used in this material are property of Siemens Medical Solutions USA or Siemens AG. All other company, brand, product and service names may be trademarks or registered trademarks
COMPENSATION MIT Flow Cytometry Core Facility
COMPENSATION MIT Flow Cytometry Core Facility Why do we need compensation? 1) Because the long emission spectrum tail of dyes causes overlap like with the fluorophores FITC and PE. 2) For sensitivity reasons,
R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.
R/F Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening Department of Radiology, National Cancer Center Hospital East Kaoru Shimizu Ms. Kaoru Shimizu 1. Introduction
Molecular Imaging: from cell to man
Molecular Imaging: from cell to man Torino, 24 November 2011 Advances in PET/SPECT technology for pre-clinical molecular imaging applications Alberto Del Guerra Dipartimento di Fisica "E.Fermi' Università
Advanced MRI methods in diagnostics of spinal cord pathology
Advanced MRI methods in diagnostics of spinal cord pathology Stanisław Kwieciński Department of Magnetic Resonance MR IMAGING LAB MRI /MRS IN BIOMEDICAL RESEARCH ON HUMANS AND ANIMAL MODELS IN VIVO Equipment:
Pediatric Hospitals Bring Low-dose CT to the Middle East
Pediatric Hospitals ring Low-dose CT to the Middle East For years, radiologists have been cognizant of the importance of limiting pediatric patients exposure to radiation dose. uilding on the LR principle,
Hitachi Healthcare Company - Our Strategy and Opportunities -
Innovative collaboration for better healthcare [Session III: Some tools for the future healthcare system] Hitachi Healthcare Company - Our Strategy and Opportunities - Masahiro Kitano Senior Vice President
Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999
Spiral CT: Single and Multiple Detector Systems AAPM Refresher Course Nashville, TN July 28,1999 Mike McNitt-Gray, PhD, DABR Assistant Professor UCLA Radiological Sciences [email protected] X-Ray
A Three-Dimensional Correlation Method for Registration of Medical Images in Radiology
A Three-Dimensional Correlation Method for Registration of Medical Images in Radiology Michalakis F. Georgiou 1, Joachim H. Nagel 2, George N. Sfakianakis 3 1,3 Department of Radiology, University of Miami
Short Courses in Imaging Sciences
Short Courses in Imaging Sciences The Centre for In Vivo Imaging Science (CIVIS) is delighted to offer online Continuing Professional Education to support your educational objectives, career goals and
Advances in scmos Camera Technology Benefit Bio Research
Advances in scmos Camera Technology Benefit Bio Research scmos camera technology is gaining in popularity - Why? In recent years, cell biology has emphasized live cell dynamics, mechanisms and electrochemical
Purchasing a cardiac CT scanner: What the radiologist needs to know
Purchasing a cardiac CT scanner: What the radiologist needs to know Maria Lewis ImPACT St George s Hospital, London [email protected] CT scanner development Slice wars 1998 Increased z-coverage
Powder diffraction and synchrotron radiation
Powder diffraction and synchrotron radiation Gilberto Artioli Dip. Geoscienze UNIPD CIRCe Center for Cement Materials single xl diffraction powder diffraction Ideal powder Powder averaging Textured sample
QAV-PET: A Free Software for Quantitative Analysis and Visualization of PET Images
QAV-PET: A Free Software for Quantitative Analysis and Visualization of PET Images Brent Foster, Ulas Bagci, and Daniel J. Mollura 1 Getting Started 1.1 What is QAV-PET used for? Quantitative Analysis
Challenge of FUJIFILM in Medical ICT
Challenge of FUJIFILM in Medical ICT Sep.10, 2014 FORWARD-LOOKING STATEMENTS Forward-looking statements, such as those relating to earnings forecasts and other projections contained in this material, are
Imaging Science. Prof. Dr. rer. nat. Bernd Pichler
Imaging Science Prof. Dr. rer. nat. Bernd Pichler Department Radiologie Diagnostic and lnterventional Radiology Prof. Nikolaou Diagnostic and lnterventional Neuroradiology Prof. Ernemann Nuclear Medicine
DENTAL Cone beam 3D X-RAY SYSTEM with
VERSATILE INTUITIVE efficient DENTAL Cone beam 3D X-RAY SYSTEM with dedicated panoramic imaging With thirty years of experience in designing and manufacturing state-of-the-art dental panoramic and tomographic
THORACIC DIAGNOSTIC ASSESMENT PROGRAM (DAP) PATIENT INFORMATION FOR:
central east regional cancer program in partnership with cancer care ontario THORACIC DIAGNOSTIC ASSESMENT PROGRAM (DAP) PATIENT INFORMATION FOR: Thoracic dap booklet March2012.indd 1 SCHEDULED TESTS YOUR
Truly digital PET imaging
Advanced Molecular Imaging Vereos PET/CT Truly digital PET imaging Philips proprietary Digital Photon Counting technology Vereos PET/CT is the first commercially available scanner to offer truly digital
Stem Cell Quick Guide: Stem Cell Basics
Stem Cell Quick Guide: Stem Cell Basics What is a Stem Cell? Stem cells are the starting point from which the rest of the body grows. The adult human body is made up of hundreds of millions of different
20.309: Biological Instrumentation and Measurement. Heejin Choi Rumi Chunara Yuri Matsumoto
20.309: Biological Instrumentation and Measurement Instructors: Laboratory Instructor: Teaching Assistants: Scott Manalis and Peter So Steve Wasserman Jaewon Cha Heejin Choi Rumi Chunara Yuri Matsumoto
How To Improve Your Ct Image Quality
Translating Protocols Between Scanner Manufacturer and Model Cynthia H. McCollough, PhD, FACR, FAAPM Professor of Radiologic Physics Director, CT Clinical Innovation Center Department of Radiology Mayo
An Introduction to Anatomy and Physiology
An Introduction to Anatomy and Physiology Objectives Define anatomy and physiology Identify the levels of organization in organisms from simplest to most complex Identify the organ systems of the human
CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions
CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions Frank N. Ranallo, Ph.D. Associate Professor of Medical Physics & Radiology University of Wisconsin School of
Positron Emission Tomography: Principles, Technology, and Recent Developments
Nuclear Physics A 752 (2005) 679c 687c Positron Emission Tomography: Principles, Technology, and Recent Developments Sibylle I. Ziegler Nuklearmedizinische Klinik, Klinikum rechts der Isar der Technischen
CD22 Antigen Is Broadly Expressed on Lung Cancer Cells and Is a Target for Antibody-Based Therapy
CD22 Antigen Is Broadly Expressed on Lung Cancer Cells and Is a Target for Antibody-Based Therapy Joseph M. Tuscano, Jason Kato, David Pearson, Chengyi Xiong, Laura Newell, Yunpeng Ma, David R. Gandara,
Approach to Lower Extremity Osteomyelitis. A radiologic tour of a patient encounter
Approach to Lower Extremity Osteomyelitis A radiologic tour of a patient encounter David Guo,, HMS III Gillian Lieberman, MD BIDMC, October 2009 Our learning goals Review lower extremity anatomy Discuss
High resolution X-ray CT as enabling technology for material research
High resolution X-ray CT as enabling technology for material research Veerle Cnudde Dept. of Geology & Soil Science - UGCT, Ghent University, Belgium With credits to the entire UGCT team (www.ugct.ugent.be)
ANATOMY & PHYSIOLOGY ONLINE COURSE - SESSION 2 ORGANIZATION OF THE BODY
ANATOMY & PHYSIOLOGY ONLINE COURSE - SESSION 2 ORGANIZATION OF THE BODY Human beings are arguably the most complex organisms on this planet. Imagine billions of microscopic parts, each with its own identity,
PET/CT-MRI First clinical experience
20 th April 2013, Barcelona, Sp PET/CT-MRI First clinical experience Philippe Appenzeller, MD Staff Radiologist and Nuclear Medicine Physician Department Medical Imaging, University Hospital Zurich PET/CT-MR
Smoking and misuse of certain pain medicines can affect the risk of developing renal cell cancer.
Renal cell cancer Renal cell cancer is a disease in which malignant (cancer) cells form in tubules of the kidney. Renal cell cancer (also called kidney cancer or renal adenocarcinoma) is a disease in which
Fluorescent Array Imaging Reader
Fluorescent Array Imaging Reader Multiplex Enabled For 2-Color Fluorescent Microarrays Extended Dynamic Range Automated Spot Analysis Compact and Affordable Microarray Analysis With FLAIR FLAIR Sensovation
CPT Radiology Codes Requiring Review by AIM Effective 01/01/2016
CPT Radiology Codes Requiring Review by AIM Effective 01/01/2016 When a service is authorized only one test per group is payable. *Secondary codes or add-on codes do not require preauthorization or separate
rmn² Teaching Program 2014
rmn² Teaching Program 2014 8010.- Institute of Physiology & Pathophysiology Methods in Cellular Neuroscience Prof. Dr.Mittmann, Prof. Dr.H. Luhmann, Dr. R. White, PD Dr. S. Kirischuk, PD. Dr. W. Kilb 5
Automated Pose Determination for Unrestrained, Non-anesthetized Small Animal Micro-SPECT and Micro-CT Imaging
Automated Pose Determination for Unrestrained, Non-anesthetized Small Animal Micro-SPECT and Micro-CT Imaging Shaun S. Gleason, Ph.D. 1, James Goddard, Ph.D. 1, Michael Paulus, Ph.D. 1, Ryan Kerekes, B.S.
Tandem Scanner. Leica TCS SP5 II: The Broadband Confocal High Speed and High Resolution All in One
Tandem Scanner Leica TCS SP5 II: The Broadband Confocal High Speed and High Resolution All in One Modern microscopy comes in two versions. On the one hand, the goal is to record brilliant images to clearly
A912: Kidney, Renal cell carcinoma
A912: Kidney, Renal cell carcinoma General facts of kidney cancer Renal cell carcinoma, a form of kidney cancer that involves cancerous changes in the cells of the renal tubule, is the most common type
Imaging Informatics Ann Scherzinger, PhD, CIIP C-TRIC Lecture Series, May 18, 2011
Imaging Informatics Ann Scherzinger, PhD, CIIP C-TRIC Lecture Series, May 18, 2011 Science of Information and Information Processing! Breadth, depth of current activities in human medical imaging informatics!
Concepts for High-Resolution Low-Dose CT of the Breast
RSNA 2012 Refresher Course 721B, Chicago, Nov. 30, 2012 Concepts for High-Resolution Low-Dose CT of the Breast Disclosures WAK is founder, shareholder and CEO of CT Imaging GmbH, Erlangen, Germany. Willi
The Dedicated MRI Factbook. Esaote MRI: A world of difference
The Dedicated MRI Factbook Esaote MRI: A world of difference Esaote Dedicated MRI Measures of Excellence Creativity in Healthcare is Esaote s motto which represents the philosophy that has been adopted
Breast Cancer: from bedside and grossing room to diagnoses and beyond. Adriana Corben, M.D.
Breast Cancer: from bedside and grossing room to diagnoses and beyond Adriana Corben, M.D. About breast anatomy Breasts are special organs that develop in women during puberty when female hormones are
MIRAX SCAN The new way of looking at pathology
Microscopy from Carl Zeiss MIRAX SCAN The new way of looking at pathology Greater reliability. Greater efficiency. Virtual microscopy for research & analysis. Better. More efficient. Quality as the basis
pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps 37 500:1 > 70 % pco. low noise high resolution high speed high dynamic range
edge 4.2 LT scientific CMOS camera high resolution 2048 x 2048 pixel low noise 0.8 electrons USB 3.0 small form factor high dynamic range 37 500:1 high speed 40 fps high quantum efficiency > 70 % edge
Metastatic Renal Cell Carcinoma: Staging and Prognosis of Three Separate Cases.
Metastatic Renal Cell Carcinoma: Staging and Prognosis of Three Separate Cases. Abstract This paper describes the staging, imaging, treatment, and prognosis of renal cell carcinoma. Three case studies
Fluorescence Microscopy for an NMR- Biosensor Project
Fluorescence Microscopy for an NMR- Biosensor Project Ole Hirsch Physikalisch-Technische Bundesanstalt Medical Optics Abbestr. -1, 10587 Berlin, Germany Overview NMR Sensor Project Dimensions in biological
MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington
MDCT Technology Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington ACMP Annual Meeting 2008 - Seattle, WA Educational Objectives Historical
Mesothelioma. 1995-2013, The Patient Education Institute, Inc. www.x-plain.com ocft0101 Last reviewed: 03/21/2013 1
Mesothelioma Introduction Mesothelioma is a type of cancer. It starts in the tissue that lines your lungs, stomach, heart, and other organs. This tissue is called mesothelium. Most people who get this
Data deluge (and it s applications) Gianluigi Zanetti. Data deluge. (and its applications) Gianluigi Zanetti
Data deluge (and its applications) Prologue Data is becoming cheaper and cheaper to produce and store Driving mechanism is parallelism on sensors, storage, computing Data directly produced are complex
Preclinical Imaging Centre (PRIME)
Preclinical Imaging Centre (PRIME) Visiting address PRIME (route 231) Geert Grooteplein 29 6525 EZ Nijmegen The Netherlands www.umcn.nl/prime Nicole Bakker [email protected] 31 (024) 3668258
GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time
Module 8: IQ: Acquisition Time IQ : Acquisition Time Objectives...Describe types of data acquisition modes....compute acquisition times for 2D and 3D scans. 2D Acquisitions The 2D mode acquires and reconstructs
2016 CPT Radiology, ECHO, and PET Codes Requiring Review Modality Body Part Group # CPT Description Default CPT "1"
26 CPT Radiology, ECHO, and PET Codes Requiring Review (Please Note: Group # and Default CPT "" are for internal claims processing use only) Modality Body Part Default CPT "" CT Head 748 CT orbit, sella
PET/CT in Lung Cancer
PET/CT in Lung Cancer Rodolfo Núñez Miller, M.D. Nuclear Medicine and Diagnostic Imaging Section Division of Human Health International Atomic Energy Agency Vienna, Austria GLOBOCAN 2012 #1 #3 FDG-PET/CT
GE Healthcare. pet/ct for simulation. Precision in motion.
GE Healthcare pet/ct for simulation. Precision in motion. Patient profile H: 5 10 W: 370 lbs BMI: 53 Each cancer patient is just as unique as his or her cancer. Approaches to cancer treatment are changing
General Information About Non-Small Cell Lung Cancer
General Information About Non-Small Cell Lung Cancer Non-small cell lung cancer is a disease in which malignant (cancer) cells form in the tissues of the lung. The lungs are a pair of cone-shaped breathing
Proton Therapy Center Czech
Proton Therapy Center Czech The main goal of radiotherapy is to irreversibly damage tumor cells, whereas the cells of healthy tissue are damaged only reversibly or not at all. Proton therapy currently
American College of Radiology CT Accreditation Program. Testing Instructions
American College of Radiology CT Accreditation Program Testing Instructions (Revised July 24, 2015) This guide provides all of the instructions necessary for clinical tests, phantom tests and general submission
ESRF Upgrade Phase II: le nuove opportunitá per le linee da magnete curvante
LUCI DI SINCROTRONE CNR, ROMA 22 APRILE 2014 ESRF Upgrade Phase II: le nuove opportunitá per le linee da magnete curvante Sakura Pascarelli [email protected] Page 2 INCREASE IN BRILLIANCE H emittance V emittance
Introduction Breast cancer is cancer that starts in the cells of the breast. Breast cancer happens mainly in women. But men can get it too.
Male Breast Cancer Introduction Breast cancer is cancer that starts in the cells of the breast. Breast cancer happens mainly in women. But men can get it too. Many people do not know that men can get breast
Rodenstock Photo Optics
Rogonar Rogonar-S Rodagon Apo-Rodagon N Rodagon-WA Apo-Rodagon-D Accessories: Modular-Focus Lenses for Enlarging, CCD Photos and Video To reproduce analog photographs as pictures on paper requires two
People Living with Cancer
Patient Guide ASCOInformation for People Living with Cancer ADVANCED LUNG CANCER TREATMENT Recommendations of the American Society of Clinical Oncology Welcome The American Society of Clinical Oncology
False positive PET in lymphoma
False positive PET in lymphoma Thomas Krause Introduction and conclusion 2 3 Introduction 4 FDG-PET in staging of lymphoma 34 studies with 2227 Patients CT FDG-PET Sensitivity 63 % 89 % (58%-100%) (63%-100%)
Transformation of the bacterium E. coli. using a gene for Green Fluorescent Protein
Transformation of the bacterium E. coli using a gene for Green Fluorescent Protein Background In molecular biology, transformation refers to a form of genetic exchange in which the genetic material carried
State-of-the-Art Technology in Cardiac CT
1 2 Next Step Evolution or Revolution? State-of-the-Art Technology in Cardiac CT Stefan Ulzheimer, PhD Global Director of Collaborations CT Siemens Medical Solutions Major Innovations in CT Head The 80
Performance Comparison of Four Commercial GE Discovery PET/CT Scanners: A Monte Carlo Study Using GATE
Performance Comparison of Four Commercial GE Discovery PET/CT Scanners: A Monte Carlo Study Using Parham Geramifar 1,3,4, Mohammad Reza Ay 2,3,4, Mojtaba Shamsaie Zafarghandi 1, George Loudos 5, Arman
P R E S E N T S Dr. Mufa T. Ghadiali is skilled in all aspects of General Surgery. His General Surgery Services include: General Surgery Advanced Laparoscopic Surgery Surgical Oncology Gastrointestinal
What If I Have a Spot on My Lung? Do I Have Cancer? Patient Education Guide
What If I Have a Spot on My Lung? Do I Have Cancer? Patient Education Guide A M E R I C A N C O L L E G E O F C H E S T P H Y S I C I A N S Lung cancer is one of the most common cancers. About 170,000
PET/CT QC/QA. Quality Control in PET. Magnus Dahlbom, Ph.D. Verify the operational integrity of the system. PET Detectors
Quality Control in PET PET/CT QC/QA Magnus Dahlbom, Ph.D. Division of Nuclear Medicine Ahmanson Biochemical Imaging Clinic David Geffen School of Medicine at UCLA Los Angeles Verify the operational integrity
product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology
product overview family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology scmos knowledge base scmos General Information PCO scmos cameras are a breakthrough
In room Magnetic Resonance Imaging guided Radiotherapy (MRIgRT( MRIgRT) Jan Lagendijk and Bas Raaymakers
In room Magnetic Resonance Imaging guided Radiotherapy (MRIgRT( MRIgRT) Jan Lagendijk and Bas Raaymakers : Chris Bakker Boxue Liu Alexander Raaijmakers Rajko Topolnjak Richard van de Put Uulke van der
CCR Biology - Chapter 9 Practice Test - Summer 2012
Name: Class: Date: CCR Biology - Chapter 9 Practice Test - Summer 2012 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Genetic engineering is possible
CHAPTER 9 BODY ORGANIZATION
CHAPTER 9 BODY ORGANIZATION Objectives Identify the meaning of 10 or more terms relating to the organization of the body Describe the properties of life Describe the function for the structures of the
Our Facility. Advanced clinical center with the newest and highly exact technology for treatment of patients with cancer pencil beam
PTC Czech The main goal of radiotherapy is to irreversibly damage tumor cells, whereas the cells of healthy tissue are damaged only reversibly or not at all. Proton therapy currently comes closest to this
PT-Netzwerk-Kamera, Tag/Nacht, PoE 802.3af, IR LEDs, 2-Megapixel
FCS-6020 Version: 1 PT-Netzwerk-Kamera, Tag/Nacht, PoE 802.3af, IR LEDs, 2-Megapixel The LevelOne FCS-6020 is a quality yet cost-effective surveillance solution for the home and office. It is designed
Preliminary Results from a Phase 2 Study of ARQ 197 in Patients with Microphthalmia Transcription Factor Family (MiT) Associated Tumors
Preliminary Results from a Phase 2 Study of ARQ 197 in Patients with Microphthalmia Transcription Factor Family (MiT) Associated Tumors John Goldberg 1 *, George Demetri 2, Edwin Choy 3, Lee Rosen 4, Alberto
A Passive RFID Implant for Soft Tissue Trauma Monitoring
A Passive RFID Implant for Soft Tissue Trauma Monitoring J.M. Rigelsford and C. J. Davenport Department of Electronic & Electrical Engineering, The University of Sheffield, Sheffield, S1 3JD, UK Background
MRC High Resolution. MR-compatible digital HD video camera. User manual
MRC High Resolution MR-compatible digital HD video camera User manual page 1 of 12 Contents 1. Intended use...2 2. System components...3 3. Video camera and lens...4 4. Interface...4 5. Installation...5
Current Industry Neuroimaging Experience in Clinical Trials Jerome Barakos, M.D.
Current Industry Neuroimaging Experience in Clinical Trials Jerome Barakos, M.D. Melbourne Australia March 28, 2012 Synarc Experience and Expertise Largest imaging service provider dedicated to clinical
Chapter 16 Reproductive Technology, Gene Therapy, and Stem Cells (modified)
Chapter 16 Reproductive Technology, Gene Therapy, and Stem Cells (modified) Assisted Reproductive Technologies (ART) Artificial insemination (AI) In vitro fertilization (IVF) Gamete intrafallopian transfer
What You Need to know about Your Pet s Upcoming Dentistry and Periodontal Treatment
What You Need to know about Your Pet s Upcoming Dentistry and Periodontal Treatment We are sending this packet of information in anticipation of your pet s upcoming dental procedure. Many people have questions
Bio and Polymer Analytics. RD Instrumental Analytical Chemistry. Organic Trace Analytics. RD Environmental & Process Analytics
MOLEKULARE IMAGING MASSENSPEKTROMETRIE VON GEWEBSOBERFLÄCHEN und BIOPOLYMERANALTIK Günter Allmaier RESEARCH GROUP BIO- AND POLYMER ANALYSIS Vienna University of Technology, Institute of Chemical Technologies