Configure Your FuzzyScan

Size: px
Start display at page:

Download "Configure Your FuzzyScan"

Transcription

1 Configure Your FuzzyScan A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding Before you trying to configure the FuzzyScan, you must refer to the Quick Installation chapter of reading devices or other equipment to settle the installation. Otherwise, unexpected conditions may occur while setting the FuzzyScan. There are two ways to configure your FuzzyScan, depending on the model you brought from your vendors. Via FuzzyScan PowerTool PowerTool is a unique software utility designed for FuzzyScan Gold/Jade/Diamond series scanners only. It has been designed to operate under Microsoft Windows 95, 98, NT or above. To use the PowerTool, you will enjoy the convenience on your fingertip. Via Bar Code Programming Menu The bar code programming menu is designed for field programming convenience. All FuzzyScan family scanners can take this way to make detailed configurations. Before you using the bar code programming menu, please understand the command structure and various programming procedures in advance. Copyright 999 PC Worth Int l Co., Ltd. Copyright 999 Cino Group -

2 FuzzyScan PowerTool PowerTool is the only Microsoft Windows 95/98/NT based software utility available in the Auto ID industry. This software utility has totally changed the way to manage the intelligent bar code reading device, and has redefined the terminology of user-friendly in this industry. These extra benefits brought to you are done via outstanding software designs and on-board hardware breakthrough with the most advanced Flash Memory ASIC. If you are the user of FuzzyScan Gold/Jade/Diamond series scanners, you can obtain PowerTool Solution Pack in lowest cost as bonus. With innovative design, PowerTool can provide you the convenience of: User Friendly On-screen Configuration Configuration Download and Upload Program (Firmware) Field Upgrade PowerTool at A Glance PowerTool Main Screen Host Interface Selection Simple On-site Diagnostic Full-feature Data Editor DataWizard While you are asking PowerTool to do the Download, Upload, Upgrade and Diagnostic with FuzzyScan, PowerTool will ask you to use FuzzyScan to scan the Host Link Command for initial handshaking with PowerTool, then perform your desired action. DataWizard Setting FuzzyScan PowerTool Host Link Command Bar Code Setting -

3 Software Installation PowerTool comes with the PowerTool Solution Pack which includes the necessary cable sets, operation briefing and software delivered in CD ROM or floppy format. You will find the PowerTool has been delivered in a self-extracted file format. It includes all the necessary installation files to build a complete running program. When you put the self-extracted file into a pre-built subdirectory and execute this file, those installation files will be retrieved into this subdirectory immediately. Then you have to run the SETUP.EXE and follow the screen instruction to complete the installation of FuzzyScan PowerTool. After the installation procedure, a new FuzzyScan group folder will be added into the program menu, then you are ready to use the PowerTool. On-screen Configuration Compared with the traditional configuration done via bar code menu readings, PowerTool will provide you a GUI interface to configure the FuzzyScan Universal Models easily. All configurations can be saved as a file format or convert to hard copy of print out for management convenience. Especially, the hard copy of all parameters programmed can be obtained via the Convert feature. This feature will consolidate all programmable parameters for a certain application and print it out via your printer linked with the PC. This hard copy, then, can be filed for future reference or can be used in the field where no PC is available. Configuration Download and Upload The Download and Upload functions will let you see what the device is programmed for. Also you can retrieve (upload) the configurations from FuzzyScan or send (download) the configurations to FuzzyScan. Of course, to duplicate preset configurations will be easy as --. Program Field Upgrade Internal program (firmware) change or modification is only one step away via the Field Upgrade feature of the utility. This is what we called Investment Guaranty for all of the FuzzyScan universal models. On-Site Field Diagnostic You can perform Diagnostic to verify if the communication between your FuzzyScan and Host system is normal, and the buzzer and indicator light is working correctly. -

4 DataWizard DataWizard is an Artificial Intelligence based Expert System developed by the manufacturer to handle delicate data processing jobs before the scanned data been transmitted to the host system. The DataWizard Condensed Version has been embedded in all FuzzyScan family. You can get those desired functions via scanning bar code menu. The Full- Feature DataWizard is only available for FuzzyScan Gold/Jade/Diamond series (Universal Models), and must be configured through the PowerTool for advanced requirements. It will give you the freedom of modifying the scanned data anyway you like, and allow you to integrate the FuzzyScan Universal Models into any existing applications. Briefing The ultra powerful data editing functions provided by DataWizard are controlled by user definable Rule. Through independent rules, users can easily get following functionality: General Transmission Control The available parameters include Preamble, Postamble, Suffix, Symbol ID and Data Length Transmission and Transmission Time Control. Advanced Data Verification User can base on the desired Bar Code Symbologies to select Valid ASCII Domain, Valid Data Length Domain and Matched Data Value to establish any desired filtering algorithm. This feature is not only to provide on-scanner data filter without application software modification, but also can reduce the error reading rate and improve data capture reliability. Field Oriented Data Formatter The Field Oriented Data Formatter allows user to flexibly divide scanned data by Delimiter or Length. To use with Added Field and Transmission Sequence Arrangement features, user can implement Insert, Delete, Replace, Re-organize and other data editing capabilities beyond your imagination. If you can t understand the actual operation of DataWizard, please consult your vendor or visit our web site for details. Then you will enjoy the wonderful tool on hand. -

5 Application Example If your bar code label is a 6-digit Code 9 which includes the information of 6-digit date code, 6-digit serial number and -digit unit price. You want the FuzzyScan to do the following for you without software modification: Check bar code is Code 9 or not, then reject the invalid bar code input. Check bar code content is numeric or not, then reject the invalid bar code input. Allow bar code output whose date code is leading with 99. Three outputs with TAB suffix. The date code output should skip 99 and replaced it with AA. The serial number output should be led with S/N:. The first digits of unit price output should be skipped. The output sequence should be unit price, date code, and serial number. Test Bar Code : Actual Output : 76[TAB]AA5[TAB]S/N:56[TAB] Please use FuzzyScan PowerTool to configure the full-feature DataWizard, and follow the procedures listed below. Configuration Procedure Select Using Rule. Set Applied Bar Code to Code 9. Set Valid ASCII Range to Numeric. Select Using Match. Set Matched Data to 99, and set Start Position to. Set Original Field to Divide scanned data into fields. Set Field Divided By of F to Fixed Length for. Set Field Divided By of F to Fixed Length for. Set Field Divided By of F to Fixed Length for 6. Set Field Divided By of F to Fixed Length for Then DataWizard will assign the rest digits as Last Field (LF) automatically. Please note that if the code 9 bar code label is printed with Check Digit, the last field will have digits. Set Added Field to Insert Added Fields. Set AF (Added Field ) to AA. Set AF to S/N:. Set AF to TAB (Hex 9). Set Transmission Sequence to LF, AF, AF, F, AF, AF, F, and AF. -5

6 Bar Code Programming Menu The FuzzyScan bar code commands are specially designed Proprietary bar code labels which allow you to set the FuzzyScan internal programming parameters. There are System Command, Family Code and Option Code for programming purpose. Each programmable family and bar code command label is listed on the same page with major system commands. The detailed explanations and special programming flowchart are printed on facing or following pages. You can read the explanation and set the FuzzyScan concurrently. A supplemental bar code command menu incorporates the bar code command labels of System Command and Option Code. As you set the FuzzyScan, open the bar code command menu to find the option code page. You may scan the desired family code and option code to set FuzzyScan. If you want to change the programming family for multiple settings, you need only turn over the programming page to find next desired programming family. System Command The System Command is the highest level bar code command which directs FuzzyScan to perform immediate operations, such as entering programming mode ( ), exiting programming mode (EXIT), listing system information (SYSLIST), recovering to factory preset configurations (), and so on. Please note that all system commands will take a few seconds to complete the operations. User must wait for the completion beeps before scanning another bar code. Family Code The Family Code is scanned to select the user desired programming family. FuzzyScan has already provided more than one hundred programming families to meet any specific requirements. Option Code The Option Codes is a set of bar code commands represented by 9, A F and finishing selection (). For most setting, you must select at least one option code following the family code selection to set the desired parameter for the selected programming family. -6

7 Programming Procedures As you scan the bar code command to select the desired parameters, information about the final selected parameters represented by the bar code commands are stored in the FuzzyScan s internal Flash Memory ASIC or non-volatile memory. If you turn off the unit, the Flash Memory ASIC or non-volatile memory retains all programming options. You need not re-program the FuzzyScan if you want to keep the existing configurations in the next power on. The programming procedures of FuzzyScan are designed as simple as possible for ease of setting. Most programming families take the Single Scan Selection programming procedure. But several programming families have more complex and flexible programmable options, and you must take Multiple Scans Selection, Cycling Scan Selection or Dual Level Selection to complete their programming procedures. Each kind of programming procedure is listed in the following pages for your reference. Please give careful attention to become familiar with each programming procedure. However, if you are the user of FuzzyScan Gold/Jade/Diamond series scanners, you are encouraged to use the PowerTool for convenience. If the programming family must take multiple scans selection, cycling scan selection, or dual level selection procedures, the family of the programming menu will be marked with the matched representing symbol of Programming Category (P.C.) in bold font listed in the following table. You can easily find the bold mark in the programming menu, and refer to their flowcharts for details. Before setting the FuzzyScan, please also refer to the Beeping Indications listed in Appendix to understand the details of programming beeping indications. It will be very helpful for you to know the existing status while you are programming the FuzzyScan. Conventions of Programming Menu Conventions Descriptions Factory Default Value P.C. Programming Category : Signle scan selection : Multiple scans selection CS : Cycling scan selection DS : Dual level scan selection ( ) Necessary Option Code [ ] Selectable Option Code -7

8 Program & End System List & Master Default Scan Scan SYSLIST FuzzyScan will enter programming mode, and inhibit all non-programming functions. FuzzyScan will list the product information and revision number to host via selected host interface, then issue the completion beeping ( short beeps). Scan END Scan FuzzyScan will exit programming mode, and store all parameters in Flash Memory ASIC or non-volatile memory, then issue the completion beeping ( short beeps). FuzzyScan will recover all programmable parameters into factory preset configurations, then issue the completion beeping ( short beeps). Please note that the FuzzyScan will take - seconds to store parameters in internal Flash Memory ASIC or non-volatile memory after you scan the END. Please don t turn off the power before the completion beeping. It may destroy all configured parameters. -8

9 Single scan selection Scan Multiple scans selection Enter programming mode. Scan Enter programming mode. Scan One of Family Codes Scan One of Option Codes Select one of desired programming families. Select one option code of desired parameter. Scan One of Family Codes Scan One or Select one of desired programming families.. Select one or several option codes to select Several Option Codes desired parameters. Yes Repeat Selection Want to select another programming family? Yes Repeat. If it s necessary, scan to terminate option code selection. Selection No Want to select another Scan END Exit programming mode. No Scan END programming family? Exit programming mode. -9

10 Cycling scan selection Dual level selection Scan Enter programming mode. Scan Enter programming mode. Scan One of Family Codes Select one of desired programming families. Scan One of Family Codes Select one of desired programming families. Scan One of Option Codes Cycling select one or several option codes of desired parameters as (st) Scan Several Option Codes Select several option codes of desired parameters.. Select one or several Single or Multiple option codes of desired scans selection. (nd) Scan One or parameters. Scan Several Option Codes. If it s necessary, scan Finish cycling selection. to terminate Yes Repeat Selection No (If necessary) Want to select another programming family? Yes Repeat Selection No option code selection. Want to select another programming family? Scan END Exit programming mode. Scan END Exit programming mode. -

11 Host Interface Selection FuzzyScan Gold, Jade & Diamond Series Host Interface Selection for Gold/Jade/Diamond series IBM PC/XT, 86/XT keyboard wedge interface IBM PC/AT, PS/, PS/VP series keyboard wedge interface IBM PS/, 5- series keyboard wedge interface IBM PS/, 5- series keyboard wedge interface Compaq, HP Vectra PC keyboard wedge interface Apple ADB keyboard wedge interface Standard/TTL RS- peer-to-peer serial interface Standard/TTL RS- serial wedge interface Wand emulation interface Pseudo RS- serial interface (TTL level, -wire connection only) PC/AT, PS/ keyboard replacement interface (without external keyboard) Cino Omnikey & VersaNet direct-link interface HW- terminal keyboard wedge interface General Notebook PC keyboard wedge interface (with external keybaord) General Notebook PC keyboard direct-link interface (without external keyboard) IBM SureOne keyboard wedge interface IBM SureOne standard RS- serial interface Laser emulation interface (TBD - Please check your vendor for the availability.) USB keyboard interface (for Microsoft Windows 98, and Apple imac) IBM 555 series keyboard wedge (5p) IBM 555 series keyboard wedge (6p) IBM ThinkPad keyboard direct-link interface (without external pinpad) IBM ThinkPad keyboard wedge interface (with external pinpad) A 8 87 All the above listed host interface selections are not available for FuzzyScan Lite series. All FuzzyScan Gold/Jade/Diamond series are factory defaulted as IBM PC/AT, PS/, PS/VP keyboard wedge interface. USB keyboard interface is only supported by Windows 98, Windows or above and Apple imac system. -

12 Host Interface Selection FuzzyScan Jade & Diamond Series Host Interface Selection for Jade & Diamond series IBM PS/ (code set 8) keyboard wedge interface IBM PS/ (code set 8) keyboard wedge interface IBM PS/ (code set 8) keyboard wedge interface IBM PS/ A (code set ) keyboard wedge interface IBM PS/ (code set 8A) keyboard wedge interface IBM PS/ (code set 8A) keyboard wedge interface IBM PS/ (code set 8A) keyboard wedge interface IBM PS/V PC, (code set 8) keyboard wedge interface IBM PS/V PC, (code set 8) keyboard wedge interface IBM PS/V PC, (code set 8) keyboard wedge interface IBM PS/V PC, 5576-A (code set ) keyboard wedge interface Hitachi Flora KB keyboard wedge interface Hitachi Flora KB keyboard wedge interface Compaq Desktop PC keyboard wedge interface DOS/V keyboard direct link interface Fujitsu FMV keyboard wedge interface NEC NX Notebook direct link interface NEC PC-98 keyboard wedge interface All of the above listed interfaces are not available for FuzzyScan Lite and Gold series. All of the above listed interfaces are specially for Japanese Machines. The Keyboard Wedge Interfaces of IBM/DEC/WYSE/TELEX, IBM 68/69 Traditional Interface and Variuos OCIA Interfaces are available with the FuzzyScan Diamond series only under OEM/ODM request. Please consult your local FuzzyScan vendor for details

13 Symbology Reading Control User Defined Symbol ID nd Option Code Symbol ID : character DS Code 8 (default=b) UCC/EAN-8 (default=c) UPC-A (default=a) EAN/JAN/CAN- (default=f) Codabar/NW-7 (default=d) Code 9/Code (default=g) Code 9 (default=h) Standard/Industrial of 5 (default=i) Interleaved of 5 (default=j) Matrix of 5 (default=k) China Postal Code (default=l) German Postal Code (default=m) IATA (default=o) Code (default=p) I/Plessey (default=r) UK/Plessey (default=s) Telepen (default=t) Symbol ID : character DS UPC-E (default=e) EAN-8 (default=ff) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) [- characters], [] [- characters], [] -

14 Symbology Reading Control Symbology ID Trans., Readable Bar Code Setting Symbology ID Transmission Readable Symbology Setting Remember to scan to terminate this selection. But if you select the Automatic discrimination, FuzzyScan will terminate this selection automatically. CS CS CS CS CS CS CS CS CS CS CS CS CS Disable symbology ID transmission Enable prefix symbology ID transmission Enable suffix symbology ID transmission Enable both prefix and suffix symbology ID transmission Automatic discrimination Code 8, UCC/EAN-8 UPC-A UPC-E EAN/CAN/JAN- EAN/CAN/JAN-8 Codabar/NW-7 Code 9/Code, HIBC Code 5 Family, IATA Code 9 Code I/Plessey UK/Plessey Telepen If your application is reading known, limited bar code symbologies, you may increase the reading speed and decrease the reading error possibility by selecting those known symbologies only. Furthermore, to add the Symbology ID into the transmitted data is also helpful for applications to identify the specific symbology ID. To further ensure fast, accurate readings, you can complete more complex configurations via full-feature DataWizard. To configure the full-feature DataWizard, user must use the PowerTool which is a Windows 95/98/NT based software utility specially designed for FuzzyScan Universal Interface Models (Gold, Jade and Diamond series). Please consult your local FuzzyScan vendor for details

15 Symbology Reading Control Code 9/Code Setting Code 9 Family Setting Code 9 Min. Length Code 9 Max. Length Select Standard Code 9 as primary format Select Full ASCII Code 9 as primary format Select Code (Italian Pharmaceutical) as primary format Disable start/stop symbol transmission Enable start/stop symbol transmission Disable Code leading A transmission Enable Code leading A transmission Disable MOD check digit verification Enable MOD check digit verification Disable check digit transmission Enable check digit transmission Default () -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will A -5

16 Symbology Reading Control Codabar/NW-7 Setting Codabar Setting Codabar Min. Length Codabar Max. Length Select Codabar standard format Select Codabar ABC format Select Codabar CLSI format Select Codabar CX format Disable start/stop symbol transmission Enable ABCD/ABCD start/stop symbol transmission Enable abcd/abcd start/stop symbol transmission Enable ABCD/TN*E start/stop symbol transmission Enable abcd/tn*e start/stop symbol transmission Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission Default () -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will A B C -6

17 Symbology Reading Control UPC-A & UPC-E Setting UPC Family Setting UPC-E & EAN-8 Expansion UPC-A/E Standardization Select UPC without supplement digits Select UPC with only supplement digits Select UPC with only 5 supplement digits Select UPC with /5 supplement digits Disable UPC-E expansion Enable UPC-E expansion Disable UPC standardization Enable UPC standardization Disable UPC numeric system Enable UPC numeric system Disable UPC-A check digit transmission Enable UPC-A check digit transmission Disable UPC-E check digit transmission Enable UPC-E check digit transmission Disable UPC leading portion Enable UPC leading portion : Expand the 7-digit UPC-E and 8-digit ENA-8 to -digit UPC-A and -digit EAN-. : Expand the 7-digit UPC-E and -digit UPC-A to 8-digit UPC-8 to -digit EAN- with zero insertion. UPC Lead Numeric System : Enable to read UPC leading with the numeric system, you must enable this option. WPC Selection (UPC/EAN/JAN/CAN) Basic Length Disable Check Digit Disable Numeric System With -digit Addendum With 5-digit Addendum Enable Standardization Enable Expansion UPC-A UPC-E EAN/JAN/CAN- - NC NC EAN/JAN/CAN NC NC A B C D E F -7

18 Symbology Reading Control EAN/JAN/CAN & IATASetting EAN/CAN/JAN Setting IATA Setting Select EAN without supplement digits Select EAN with only supplement digits Select EAN with only 5 supplement digits Select EAN with /5 supplement digits Disable EAN-8 expansion Enable EAN-8 expansion Disable EAN- check digit transmission Enable EAN- check digit transmission Disable EAN-8 check digit transmission Enable EAN-8 check digit transmission Disable ISBN/IN Conversion reading check Enable ISBN/IN Conversion reading check A B Select 5-digit fixed length IATA checking Select variable length IATA Disable check digit verification Enable check digit automatic verification Enable S/N checking digit verification only Enable CPN checking digit verification only 5 Enable CPN, Airline and S/N check digit verification 6 Disable start/stop symbol transmission 7 Enable start/stop symbol transmission 8 Disable check digit transmission 9 Enable check digit transmission A -8

19 Symbology Reading Control Code 5 Family & German Post Code Setting Code 5 Setting Select any Code 5 Select Standard/Industrial of 5 only Select Matrix of 5 only Select Interleaved of 5 only Select Interleaved of 5 S Code only Select IATA only 5 Select China Postal Code only 6 Disable check digit verification 7 Enable check digit verification 8 Disable check digit transmission 9 Enable check digit transmission A Code 5 Min. Length Default (6) -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will Code 5 Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will German Postal Setting Disable Enable The FuzzyScan can decode almost all Code 5 symbologies automatically. But we recommend that you select only one kind of Code 5 for reading, or set limited maximum and minimum reading length for reading, because the encoding algorithm of Code 5 isn t very good. To decode all Code 5 automatically or to read variable length Code 5 will increase the error reading rate. -9

20 Symbology Reading Control Code & Code 9 Seting Code Setting Code Min. Length Code Max. Length Code 9 Setting Select -check digit verification Select -check digit verification Disable check digit transmission Enable -check digit transmission Enable -check digit transmission Default () -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will Disable check digit transmission Enable check digit transmission Code 9 Min. Length Default () -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will Code 9 Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will -

21 Symbology Reading Control I/Plessey, Code 8 & UCC/EAN 8 Setting I/Plessey Setting I/Plessey Min. Length I/Plessey Max. Length Code 8/EAN-8 Setting Select MOD check digit Select MOD - check digit Select MOD - check digit Disable check digit transmission Enable -check digit transmission Enable -check digit transmission Default () -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will Disable function code conversion Enable function code conversion 5 Code 8/EAN-8 Min. Length Default () -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will Code 8/EAN-8 Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will -

22 Symbology Reading Control UK/Plessey & Telepen Setting UK/Plessey Setting UK/Plessey Min. Length UK/Plessey Max. Length Telepen Setting Telepen Min. Length Telepen Max. Length Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission Default () -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission Default () -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will - 5

23 Keyboard Interface Control Keyboard Layout (Language) Setting Keyboard Layout The Universal Selection is only for PC/AT, PS/VP, PS/ and compatible ones in DOS or Windows environment which can perform unique output without Caps Lock on/off (Output Style) concern. All transmitted data will follow the original full ASCII form. You also need not worry about the upper/lower case control. USA (QWERTY) France (AZERTY) Germany (QWERTZ) United Kingdom - UK (QWERTY) Canadian French (QWERTY) Spain (QWERTY) Sweden/Finland (QWERTY) Portugal (QWERTY) Norway (QWERTY) Latin America (QWERTY) Italy (QWERTY) Netherlands (QWERTY) Denmark (QWERTY) Belgium (AZERTY) Switzerland-Germany (QWERTY) Iceland (QWERTY) Universal (only available for IBM PC/AT, PS/VP in DOS and Windows Mode) Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as premble or postamble. To set preamble or postamble as function key output, you must enable the Function Key Emulation feature as listed in page -5 first. Keyboard Interface Message String : Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble Record Suffix -5 characters - digits or characters variable length or characters -5 characters character

24 Keyboard Interface Control Record Suffix, Preamble, Postamble & Delay Setting Record Suffix Preamble None RETURN TAB SPACE ENTER (Numeric Key Pad) User defined character ( character) 5, (-7F) None -5 characters [-7F], [] Maximum 5-character input; scan to terminate this selection. Postamble None -5 characters [-7F], [] Maximum 5-character input; scan to terminate this selection. Character Frame Control None -99 msec. Scan digits from the option code chart in Appendix, then FuzzyScan will Intermessage Delay None -99 (x5) msec. Scan digits from the option code chart in Appendix, then FuzzyScan will Intercharacter Delay None -99 msec. Scan digits from the option code chart in Appendix, then FuzzyScan will -

25 Keyboard Interface Control Caps Lock Control & Emulation Setting Caps Lock Control Caps Lock Off State Caps Lock On State Auto Detect (PC/AT, PS/, Keyboard Replacement and DOS/V Machines only) Function Key Emulation Enable ASCII - code as keyboard function code output Ctrl-Output Refer to Appendix Keyboard Function Code Table for details. Key Pad Emulation Disable key pad emulation Enable numeric output as key pad (Num Lock On) output Upper/Lower Case Normal case (neglect the upper/lower case control) Inverse case (change all characters output to inverse case) Upper case (force all characters output as upper case) Lower case (force all characters output as lower case) Character Frame Control is used to adjust timing gap between bytes within one character data output by FuzzyScan. Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : ) the data transmission speed is too fast, characters may be skipped; ) multitasking operation system or host computers in a network may slow down the keyboard handling; ) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safty margin when adjusting these two parameters. Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time. The function of Caps Lock Control and Key Pad Emulation are only available for IBM PC/AT, PS/VP, PS/ series personal computers and compatible machines. While selecting the other host interfaces, these selections don t perform the above functions for you. Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select Caps Lock Off state, then FuzzyScan will perform normal data transmission. If the Caps Lock state is on, select Caps Lock On state. Select Auto Detect, FuzzyScan will perform special transmission handshaking without changing the status of Caps Lock switch. -5

Table of Contents Appendix

Table of Contents Appendix Table of Contents Configure Your FuzzyScan...- Bar Code Programming Menu...- Programming Procedures...- Host Interface Selection...- Symbology Reading Control...- Keyboard Interface Control...- Serial

More information

BARCODE IMAGER. Programming Manual International Edition, Rev. A1

BARCODE IMAGER. Programming Manual International Edition, Rev. A1 BARCODE IMAGER International Edition, Rev. A Revision History Rev. No. Released Date Description Rev.. Beta Aug., 8 First Release Rev.. Beta Aug., 8 Page 9 Vibrator Default value is changed from Disable

More information

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions

More information

Index...1. Introduction...3. Installation- Keyboard Wedge...3 RS-232...3 USB...3. Default Setting for each barcode shown as below:...

Index...1. Introduction...3. Installation- Keyboard Wedge...3 RS-232...3 USB...3. Default Setting for each barcode shown as below:... Index Index...1 Introduction...3 Installation- Keyboard Wedge...3 RS-232...3 USB...3 Default Setting for each barcode shown as below:...4 Programming the MS320...5 Interface Selection...7 Keyboard wedge...8

More information

Laser Barcode Scanner User s Manual

Laser Barcode Scanner User s Manual Laser Barcode Scanner User s Manual FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are

More information

Laser Barcode Scanner

Laser Barcode Scanner Laser Barcode Scanner User s Manual FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are

More information

BARCODE READER V 2.1 EN USER MANUAL

BARCODE READER V 2.1 EN USER MANUAL BARCODE READER V 2.1 EN USER MANUAL INSTALLATION OF YOUR DEVICE PS-2 Connection RS-232 Connection (need 5Volts power supply) 1 INSTALLATION OF YOUR DEVICE USB Connection 2 USING THIS MANUAL TO SETUP YOUR

More information

Barcode Magstripe. Decoder & Scanner. Programming Manual

Barcode Magstripe. Decoder & Scanner. Programming Manual Barcode Magstripe Decoder & Scanner Programming Manual CONTENTS Getting Started... 2 Setup Procedures... 3 Setup Flow Chart...4 Group 0 : Interface Selection... 5 Group 1 : Device Selection for keyboard

More information

E-i. Section E. Code Formatting. E/D = Enable/Disable T/DNT = Transmit/Do Not Transmit EX/DNEX = Expand/Do Not Expand

E-i. Section E. Code Formatting. E/D = Enable/Disable T/DNT = Transmit/Do Not Transmit EX/DNEX = Expand/Do Not Expand Section E Code Formatting E/D = Enable/Disable T/DNT = Transmit/Do Not Transmit EX/DNEX = Expand/Do Not Expand C/DNC = Convert/Do Not Convert E/DNE = Enable/Do Not Enable T/DNT UPC-A Check Digit (E - 1)

More information

NOTICE: respective owner. Note: Specification is subject to changes without. notice.

NOTICE: respective owner. Note: Specification is subject to changes without. notice. 0 NOTICE: This device complies with Part 15 of the FCC Rules. Operation shall be subject to the following two conditions: (1) This device may not cause harmful interface, and (2) This device must accept

More information

Part No. : MUL-53221-07 PROGRAMMING GUIDE

Part No. : MUL-53221-07 PROGRAMMING GUIDE Part No. : MUL-53221-07 PROGRAMMING GUIDE PROGRAMMING GUIDE for BARCODE SCANNERS The guide can be used as keyboard emulation, RS- 232C serial interface, and USB 1.1 interface and wand emulation. IMPORTANT

More information

Xi2000 Series Configuration Guide

Xi2000 Series Configuration Guide U.S. Default Settings Sequence Reset Scanner Xi2000 Series Configuration Guide Auto-Sense Mode ON UPC-A Convert to EAN-13 OFF UPC-E Lead Zero ON Save Changes POS-X, Inc. 2130 Grant St. Bellingham, WA 98225

More information

Bar Code CCD Scanner OPERATION MANUAL

Bar Code CCD Scanner OPERATION MANUAL ISO 9002 Certified Lead with technology Win customers with service Bar Code CCD Scanner OPERATION MANUAL 69 Jarltech International Inc. 1998. All rights reserved. Under the copyright laws, this manual

More information

Scanner Configuration

Scanner Configuration Scanner Configuration SmartScan Manual DOC Version 2.21 This document is specifically designed for the user to print two pages per sheet of paper with optimal print quality. Copyright 2005~ 2008 CIPHERLAB

More information

MK-SERIE 1000/1500/2000 AllOfBarcode.de Michael Krug - 83278Traunstein BARCODE SCANNER

MK-SERIE 1000/1500/2000 AllOfBarcode.de Michael Krug - 83278Traunstein BARCODE SCANNER MK-SERIE 1000/1500/2000 AllOfBarcode.de Michael Krug - 83278Traunstein BARCODE SCANNER Configuration Guide - 1 - Table of Contents Chapter 1 System Information 1.1 About this manual 3 1.2 How to set up

More information

HANDHELD LASER SCANNER

HANDHELD LASER SCANNER HANDHELD LASER SCANNER PROGRAMMING GUIDE PSC Scanning, Inc. En Suisse: 959 Terry Street GOMARO s.a. Eugene, Oregon 97402-9120 1123 Aclens - Switzerland Telephone: (541) 683-5700 http://www.gomaro.ch/ Toll

More information

Allen-Bradley. Bar Code. 2-D Hand-Held. Programming Guide. Bar Code. Scanners. (Cat. No. 2755-HTG-4)

Allen-Bradley. Bar Code. 2-D Hand-Held. Programming Guide. Bar Code. Scanners. (Cat. No. 2755-HTG-4) Allen-Bradley 2-D Hand-Held Bar Code Scanners Bar Code Programming Guide (Cat. No. 2755-HTG-4) Important User Information The illustrations, charts, sample programs and layout examples shown in this guide

More information

METROLOGIC INSTRUMENTS, INC. MetroSelect Configuration Guide

METROLOGIC INSTRUMENTS, INC. MetroSelect Configuration Guide METROLOGIC INSTRUMENTS, INC. MetroSelect Configuration Guide Copyright 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form

More information

QuickScan i. QD2100 Barcode Imager. Product Reference Guide

QuickScan i. QD2100 Barcode Imager. Product Reference Guide QuickScan i QD2100 Barcode Imager Product Reference Guide Configuring the Interface KEYBOARD FEATURES AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/standard Key Encoding Select KBD-AT Keyboard

More information

Laser Scanner Programming Guide (SE923 laser engine)

Laser Scanner Programming Guide (SE923 laser engine) Laser Scanner Programming Guide (SE923 laser engine) CONTENT Technical note... 5 How to recognise the type of the laser barcode engine... 5 How to program the laser barcode reader into default value...

More information

METROLOGIC INSTRUMENTS INC. MetroSelect Single-Line Configuration Guide

METROLOGIC INSTRUMENTS INC. MetroSelect Single-Line Configuration Guide METROLOGIC INSTRUMENTS INC. MetroSelect Single-Line Configuration Guide Copyright 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored

More information

DUET / VS800 Scanner. DUET Scanner VS800 Scanner. Programming Kit

DUET / VS800 Scanner. DUET Scanner VS800 Scanner. Programming Kit DUET / VS800 Scanner DUET Scanner VS800 Scanner Programming Kit PSC Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Telefax: (541) 345-7140 PSC and the PSC logo are registered

More information

MS100 Bar Code Pen Reader

MS100 Bar Code Pen Reader MS100 Bar Code Pen Reader AdventureJan General Advisory Improper handling, storage, environmental influences and /or product modification can lead to problems during use. This is particularly true if repairs

More information

METROLOGIC INSTRUMENTS, INC. IS4225 ScanGlove USB Addendum for the MetroSelect Single-Line Configuration Guide

METROLOGIC INSTRUMENTS, INC. IS4225 ScanGlove USB Addendum for the MetroSelect Single-Line Configuration Guide METROLOGIC INSTRUMENTS, INC. IS4225 ScanGlove USB Addendum for the MetroSelect Single-Line Configuration Guide Copyright 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may

More information

MetroSelect Programming Guide. MLPN 2407/December 1998

MetroSelect Programming Guide. MLPN 2407/December 1998 MetroSelect Programming Guide MLPN 2407/December 1998 Locations: USA Corporate Headquarters Europe Metrologic Instruments, Inc. Metrologic Instruments GmbH 90 Coles Road Dornierstrasse 2 Blackwood, NJ

More information

HAND-HELD DEVICES II. Software Configuration Manual

HAND-HELD DEVICES II. Software Configuration Manual HAND-HELD DEVICES II Software Configuration Manual HAND-HELD DEVICES II SOFTWARE CONFIGURATION MANUAL DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy Hand-Held Devices

More information

TaoTronics Laser Barcode Scanner User s Manual

TaoTronics Laser Barcode Scanner User s Manual TaoTronics Laser Barcode Scanner User s Manual SETUP from PC keyboard For KBW or KBW/RS232 interface 1 Features * Simple installation,keyboard Wedge Serial, Wand Emulation tc * Superior keyboard wedge

More information

Programming Reference Guide HP USB Barcode Scanner

Programming Reference Guide HP USB Barcode Scanner Programming Reference Guide HP USB Barcode Scanner Document Part Number: 430944-002 August 2006 Print this document before setting up the HP USB Barcode Scanner. The document provides the programming bar

More information

Product Reference Guide

Product Reference Guide PowerScan 7000 SRI Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part

More information

MetroSelect. Single-Line Scanner. Configuration Guide

MetroSelect. Single-Line Scanner. Configuration Guide MetroSelect Single-Line Scanner Configuration Guide Disclaimer Honeywell International Inc. ( HII ) reserves the right to make changes in specifications and other information contained in this document

More information

Voyager 9520/40 Voyager GS9590 Eclipse 5145

Voyager 9520/40 Voyager GS9590 Eclipse 5145 Voyager 9520/40 Voyager GS9590 Eclipse 5145 Quick Start Guide Aller à www.honeywellaidc.com pour le français. Vai a www.honeywellaidc.com per l'italiano. Gehe zu www.honeywellaidc.com für Deutsch. Ir a

More information

Enter/Exit programming

Enter/Exit programming P/N: MUL-53247-02 Enter/Exit programming (This barcode is also found at back cover page.) Framed values are default values. All Rights Reserved This guide is designed for advanced settings of Hand Free

More information

NOTICE: respective owner. Note: Specification is subject to changes without. notice.

NOTICE: respective owner. Note: Specification is subject to changes without. notice. NOTICE: This device complies with Part 15 of the FCC Rules. Operation shall be subject to the following two conditions: (1) This device may not cause harmful interface, and (2) This device must accept

More information

Product Reference Guide. QuickScan TM QS6500/QS6500BT. General Purpose Handheld Linear Imager Bar Code Reader with Bluetooth Wireless Technology

Product Reference Guide. QuickScan TM QS6500/QS6500BT. General Purpose Handheld Linear Imager Bar Code Reader with Bluetooth Wireless Technology QuickScan TM QS6500/QS6500BT General Purpose Handheld Linear Imager Bar Code Reader with Bluetooth Wireless Technology Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402

More information

QuickScan QS6500/QS6500BT

QuickScan QS6500/QS6500BT QuickScan QS6500/QS6500BT Product Reference Guide PSC Inc 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents

More information

CD-3860 Bar Code Scanner User s Manual

CD-3860 Bar Code Scanner User s Manual CD-3860 Bar Code Scanner User s Manual Important Notice Rev. Original No warranty of any kind is made in regard to this material, including, but not limited to, implied warranties of merchantability or

More information

Wireless Laser Barcode Scanner ils 6300BU. User s Manual

Wireless Laser Barcode Scanner ils 6300BU. User s Manual Wireless Laser Barcode Scanner ils 6300BU User s Manual FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.

More information

Barcode reader setup manual

Barcode reader setup manual Barcode reader setup manual Setup procedures are as follows: 1 Scan Begin setting 2 Scan your required function and its corresponding barcode 3 Scan End setting 4 All the setting parameters will be saved

More information

S302D. Programming Guide. 2D Imaging Barcode Scanner. Advanced Handheld High-Speed Laser Scanner

S302D. Programming Guide. 2D Imaging Barcode Scanner. Advanced Handheld High-Speed Laser Scanner S302D 2D Imaging Barcode Scanner Programming Guide 1 Advanced Handheld High-Speed Laser Scanner Revision History Changes to the original manual are listed below: Version Date Description of Version 1.0

More information

MD6 Series 2D Barcode Scanner

MD6 Series 2D Barcode Scanner MD6 Series 2D Barcode Scanner User Manual Version: MD6_UM_EN_V1.1.9 2 Warning: Ensure that the optional DC adapter works at +5V, especially for the RS-232 interface cable. NOTICE: 1. All software, including

More information

QuickScan L. Barcode Scanner. Advanced Data Formatting (ADF) Guide

QuickScan L. Barcode Scanner. Advanced Data Formatting (ADF) Guide QuickScan L Barcode Scanner Advanced Data Formatting (ADF) Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights

More information

Bluetooth Version FUZZYSCAN FAMILY. Quick Start Guide WIRELESS SCANNER

Bluetooth Version FUZZYSCAN FAMILY. Quick Start Guide WIRELESS SCANNER Bluetooth Version FUZZYSCAN FAMILY Quick Start Guide WIRELESS SCANNER Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan Bluetooth Cordless Image Scanner. Powered by the combination

More information

QuickScan Mobile. Reference Manual

QuickScan Mobile. Reference Manual QuickScan Mobile Reference Manual Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of

More information

because we care MS910 Wireless Barcode Scanner Quick Guide Full user s manual is available on the enclosed CD. Version 1.2 400947G

because we care MS910 Wireless Barcode Scanner Quick Guide Full user s manual is available on the enclosed CD. Version 1.2 400947G because we care MS910 Wireless Barcode Scanner Quick Guide Full user s manual is available on the enclosed CD. Version 1.2 400947G because we care OUT OF THE BOX INTRODUCTION 2. Trigger 3. LED Indicator

More information

Register your product and get support at www.philips.com/dictation DPM8500. Barcode scanner configuration guide

Register your product and get support at www.philips.com/dictation DPM8500. Barcode scanner configuration guide Register your product and get support at www.philips.com/dictation DPM8500 Barcode scanner configuration guide Table of contents 1 Introduction 5 Operational Parameters 5 Parameter defaults 5 2 Set default

More information

Barcode Scanner User Manual V6.6.2

Barcode Scanner User Manual V6.6.2 Barcode Scanner User Manual V6.6.2 CONTENTS.......................................................................................... 1 1 2 2 3 4 13 14 15 17 17 19 19 20 22 23 23 28 29 33 42 60 65 85 87

More information

LS6300 Lecteur de code-barres laser

LS6300 Lecteur de code-barres laser WWW.SYMCOD.COM Manuel LS6300 Lecteur de code-barres laser Version: 30/04/2013 Introduction Le lecteur laser Symcod LS6300 est une solution très abordable pour la gestion de vos opérations. Toujours à la

More information

Enter/Exit Programming Mode

Enter/Exit Programming Mode Enter/Exit Programming Mode (This barcode can also be found at back cover page.) Framed values are default values. IMPORTANT NOTICE No warranty of any kind is made in regard to this material, including,

More information

DL910 SERIES. Instruction Manual

DL910 SERIES. Instruction Manual DL910 SERIES Instruction Manual DL910 SERIES INSTRUCTION MANUAL ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification. Datalogic shall not

More information

Scanner Configuration Manager Manual. for PC type computers

Scanner Configuration Manager Manual. for PC type computers Scanner Configuration Manager Manual for PC type computers TABLE OF CONTENTS 1. SCANNER CONFIGURATION MANAGER......... 1 Start it Up...................... 1 First Look...................... 3 Settings......................

More information

All brand, product and service, and trademark names are the property of their registered owners.

All brand, product and service, and trademark names are the property of their registered owners. Copyright 2010 EQUATOR LIMITED All rights reserved. All intellectual property rights are the property of their owners. EQUATOR LIMITED is authorized the right to use the software; it is provided under

More information

CT20 Barcode Scanner User Manual

CT20 Barcode Scanner User Manual CT20 Barcode Scanner User Manual IMPORTANT NOTICE Safety Precaution * DO NOT disassemble the scanner, or place foreign matter into the scanner cause a short circuit or circuit damage. * DO NOT expose the

More information

Wireless Scanner. User s Manual - MS910 - Version 1.0

Wireless Scanner. User s Manual - MS910 - Version 1.0 Wireless Scanner - MS910 - User s Manual Version 1.0 Table of Contents Chapter 1 Overview... 1 Introducing the MS910... 1 Package Contents... 2 Chapter 2 Installation and Connection... 5 Connecting (Pairing)

More information

BCST-20 Barcode Scanner. Instruction Manual. www.inateck.com

BCST-20 Barcode Scanner. Instruction Manual. www.inateck.com BCST-20 Barcode Scanner Instruction Manual www.inateck.com IMPORTANT NOTICE Safety Precaution * DO NOT disassemble the scanner, or place foreign matter into the scanner causing a short circuit or circuit

More information

USER'S GUIDE NUSCAN 2100 Series

USER'S GUIDE NUSCAN 2100 Series BARCODE SCANNER USER'S GUIDE NUSCAN 2100 Series Table of Contents 1. Limited Warranty...1 2. Introduction...2 3. Contents...3 4. Barcode Symbologies...3 5. Product Introduction...3 6. Installation...4

More information

FR4060 Akame Fixed Mount Barcode Scanner. User Guide

FR4060 Akame Fixed Mount Barcode Scanner. User Guide FR4060 Akame Fixed Mount Barcode Scanner User Guide Disclaimer 2015 Fujian Newland Auto-ID Tech. Co., Ltd. All rights reserved. Please read through the manual carefully before using the product and operate

More information

BI-300. Barcode configuration and commands Manual

BI-300. Barcode configuration and commands Manual BI-300 Barcode configuration and commands Manual 1. Introduction This instruction manual is designed to set-up bar code scanner particularly to optimize the function of BI-300 bar code scanner. Terminal

More information

SocketScan Software Advanced Programming Guide

SocketScan Software Advanced Programming Guide SocketScan Software Advanced Programming Guide A guide to help you program symbology and parameter settings for the following Socket barcode scanning products: Secure Digital Scan Card Series 3 CompactFlash

More information

TMCT-10 Barcode Scanner User Manual. 102, 5661-99 St. Edmonton, AB T6E 3N8 Ph. 780.988.0215 Fax 780.988.0465

TMCT-10 Barcode Scanner User Manual. 102, 5661-99 St. Edmonton, AB T6E 3N8 Ph. 780.988.0215 Fax 780.988.0465 TMCT-10 Barcode Scanner User Manual 102, 5661-99 St. Edmonton, AB T6E 3N8 Ph. 780.988.0215 Fax 780.988.0465 IMPORTANT NOTICE Safety Precaution * DO NOT disassemble the scanner, or place foreign matter

More information

1166 / 1266 Barcode Scanner

1166 / 1266 Barcode Scanner 1166 / 1266 Barcode Scanner Setup barcodes included. Version 3.03 Copyright 2005~2014 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is

More information

QuickScan TM L QD 2300 Bar Code Scanner

QuickScan TM L QD 2300 Bar Code Scanner QuickScan TM L QD 2300 Bar Code Scanner Product Reference Guide Datalogic ADC, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 2007-2014 Datalogic ADC, Inc. An

More information

FS380 Fixed Barcode Scanner

FS380 Fixed Barcode Scanner FS380 Fixed Barcode Scanner User Manual Version: FS380_UM_EN_V1.2.4 Notice Make sure you carefully read the following information to ensure that your barcode scanner is able to perform at the level for

More information

Metrologic MS1690 2D Scanner Installation Guide

Metrologic MS1690 2D Scanner Installation Guide Metrologic MS1690 2D Scanner Installation Guide Revision 1.0 Revision History 1.0 04/17/2007 Initial Release The latest version of this document can be found in the following places: Internally for Cerner

More information

1.1 Notice... 3 1.2 Introduction... 4 1.3 Codes Read... 4 1.4 Installation... 4 1.5 Pin Assignment... 6. Configuration - General

1.1 Notice... 3 1.2 Introduction... 4 1.3 Codes Read... 4 1.4 Installation... 4 1.5 Pin Assignment... 6. Configuration - General BAR CODE Contents Chapter 1 Description 1.1 Notice... 3 1.2 Introduction... 4 1.3 Codes Read... 4 1.4 Installation... 4 1.5 Pin Assignment... 6 Chapter 2 Configuration - General 2.1 Flow Chart... 8 2.2

More information

Bar Code Reader Models 1000/1002 USER'S MANUAL 2190 Regal Parkway Euless, TX 76040 (817) 571-9015 (800) 648-4452 FAX (817) 685-6232 FCC NOTICE WARNING: This equipment generates, uses and can radiate radio

More information

Synergy Controller Application Note 4 March 2012, Revision F Tidal Engineering Corporation 2012. Synergy Controller Bar Code Reader Applications

Synergy Controller Application Note 4 March 2012, Revision F Tidal Engineering Corporation 2012. Synergy Controller Bar Code Reader Applications Synergy Controller Bar Code Reader Applications Synergy Controller with Hand Held Products Bar Code Scanner OCR-A Labeled Part Introduction The value of the ubiquitous Bar Code Scanner for speeding data

More information

Barcode Scanning Made Easy. WWS500 Programming Guide

Barcode Scanning Made Easy. WWS500 Programming Guide Barcode Scanning Made Easy WWS500 Programming Guide Table of Contents Chapter 1. Introduction...........................2 Chapter 2. Barcode Symbologies...................3 Chapter 3. Quick Start............................4

More information

Barcode Scanning Made Easy. Programming Guide

Barcode Scanning Made Easy. Programming Guide Barcode Scanning Made Easy Programming Guide CCD Scanner Programming Guide Please Read Note: The Wasp WCS3900 Series Scanners are ready to scan the most popular barcodes out of the box. This manual should

More information

PowerScan 7000 2D Imager

PowerScan 7000 2D Imager PowerScan 7000 2D Imager Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved.

More information

Magellan TM 3200VSi. On-Counter Vertical Presentation Scanner. Product Reference Guide

Magellan TM 3200VSi. On-Counter Vertical Presentation Scanner. Product Reference Guide Magellan TM 3200VSi On-Counter Vertical Presentation Scanner Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An

More information

Revision History. Advanced Handheld CCD/Laser Scanner

Revision History. Advanced Handheld CCD/Laser Scanner Revision History Changes to the original manual are listed below: Version Date Description of Version 1.0 September 9, 2010 Initial release 1.1 February 18, 2011 Added Blink mode selections. i Important

More information

MK-5200 2D Imager Barcode Scanner Configuration Guide

MK-5200 2D Imager Barcode Scanner Configuration Guide MK-5200 2D Imager Barcode Scanner Configuration Guide V 1.2 Programming the Engine Code Programming On/Off Read the barcode to activate Code Programming function. One or more Code Programming barcodes

More information

2 Advanced Scanner Configuration Guide

2 Advanced Scanner Configuration Guide 2 Advanced Scanner Configuration Guide Table of contents Introduction...4 Operational Parameters...4 Set Default Parameter...7 Default Parameters...7 Beeper Volume...7 Beeper Tone...8 Beeper Frequency

More information

Touch TD1100 Family General Purpose Corded Handheld Contact Imager Bar Code Reader

Touch TD1100 Family General Purpose Corded Handheld Contact Imager Bar Code Reader Touch TD1100 Family General Purpose Corded Handheld Contact Imager Bar Code Reader Product Reference Guide Datalogic ADC, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541)

More information

QUICK START GUIDE. Wasp WLS 9500. www.waspbarcode.com

QUICK START GUIDE. Wasp WLS 9500. www.waspbarcode.com QUICK START GUIDE Wasp WLS 9500 www.waspbarcode.com LED Scan Window Beeper Trigger CORD ATTACHMENT Model Number and Serial Number appear here. Cable interface Interface cable modular connector Interface

More information

ADVANCED DATA FORMATTING (ADF) PROGRAMMER GUIDE

ADVANCED DATA FORMATTING (ADF) PROGRAMMER GUIDE ADVANCED DATA FORMATTING (ADF) PROGRAMMER GUIDE ADVANCED DATA FORMATTING PROGRAMMER GUIDE 72E-69680-04 Revision A April 2015 ii Advanced Data Formatting Programmer Guide No part of this publication may

More information

Symbol LS9203. Product Reference Guide

Symbol LS9203. Product Reference Guide Symbol LS9203 Product Reference Guide Symbol LS9203 Product Reference Guide 72E-71538-03 Revision A February 2007 Motorola, Inc. 2007. All rights reserved. No part of this publication may be reproduced

More information

CipherLab 5100 Time Attendance Utility Manual

CipherLab 5100 Time Attendance Utility Manual CipherLab 5100 Time Attendance Utility Manual K:\Products\Product Technical\BI\BI-PC5100T\CipherLab5100TimeAttendnaceUtilityManual0707-process.doc Page 1 / 13 1 Login A popup form as follows will appear

More information

Users Manual. QuickBarII Single-Chip Bar Code Decoder

Users Manual. QuickBarII Single-Chip Bar Code Decoder Users Manual QuickBarII Single-Chip Bar Code Decoder REV E Dec. 22, 2009 LIMITED WARRANTY ID TECH warrants to the original purchaser for a period of 12 months from the date of invoice that this product

More information

Xenon 1900. Corded Area-Imaging Scanner. Quick Start Guide

Xenon 1900. Corded Area-Imaging Scanner. Quick Start Guide Xenon 1900 Corded Area-Imaging Scanner Quick Start Guide Note: Refer to your user s guide for information about cleaning your device. For localized language versions of this document, go to www.honeywellaidc.com.

More information

MetroSelect Single Line Configuration Guide. MS9500 Voyager Series i

MetroSelect Single Line Configuration Guide. MS9500 Voyager Series i MetroSelect Single Line Configuration Guide MS9500 Voyager Series i LOCATIONS Corporate Headquarters Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO 90 Coles Road Tel: 856-228-8100 Blackwood,

More information

Installing Your POS Hardware

Installing Your POS Hardware Installing Your POS Hardware! Installing Your Barcode Scanner Remove the scanner from the packing materials. Attach the Y-cable to the scanner. Orient the connector on one end of the Y-cable so it has

More information

Important Bluetooth. and Software Considerations for Wireless Barcode Scanner Deployments

Important Bluetooth. and Software Considerations for Wireless Barcode Scanner Deployments Important Bluetooth and Software Considerations for Wireless Barcode Scanner Deployments By LEN OTT, Chief Technical Officer, Socket Mobile, Inc. February 2011 Before deploying a Bluetooth barcode scanner,

More information

Voyager 1202g BF. Quick Start Guide. Cordless Single-Line Laser Bar Code Scanner and CCB00-010BT-01N-BF base

Voyager 1202g BF. Quick Start Guide. Cordless Single-Line Laser Bar Code Scanner and CCB00-010BT-01N-BF base Voyager 1202g BF Cordless Single-Line Laser Bar Code Scanner and CCB00-010BT-01N-BF base Quick Start Guide Aller à www.honeywellaidc.com pour le français. Vai a www.honeywellaidc.com per l'italiano. Gehe

More information

BARCODE PRINTING SET UP BARCODE PRINTING

BARCODE PRINTING SET UP BARCODE PRINTING 21 BARCODE PRINTING The Barcode Printing option can be purchased for an additional cost. You will receive a floppy disk or CD that you can use to activate this feature. SET UP BARCODE PRINTING To start,

More information

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate

More information

Programming Menu V3.9

Programming Menu V3.9 BAR CODE Programming Menu V3.9 Notice The manufacturer shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages in connection with

More information

APPENDIX E COMMAND BARCODES

APPENDIX E COMMAND BARCODES APPENDIX E COMMAND BARCODES Scan command barcode(s) to quickly configure the Socket Bluetooth Cordless Hand Scanner v3 (1D laser versions). By default, the CHS is in HID mode as a Keyboard device. IMPORTANT!

More information

LS 4004 ISBT 128/ABC Codabar Product Reference Guide

LS 4004 ISBT 128/ABC Codabar Product Reference Guide LS 4004 ISBT 128/ABC Codabar Product Reference Guide Click on red text at any location in the manual to jump to the specified chapter, topic, or reference. About This Manual Introduction to LS 4004 ISBT

More information

1500/1502 Series Barcode Scanner

1500/1502 Series Barcode Scanner 1500/1502 Series Barcode Scanner Setup barcodes included. Version 1.20 Copyright 2008~2015 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.;

More information

3800 Linear Series. Quick Start Guide

3800 Linear Series. Quick Start Guide 3800 Linear Series Quick Start Guide Note: Refer to your user s guide for information about cleaning your device. For localized language versions of this document, go to www.honeywell.com/aidc. Getting

More information

ScanMaster for Scanner Configuration

ScanMaster for Scanner Configuration ScanMaster for Scanner Configuration For 1 Series Barcode Scanners: 1070, 1500, 1502 (1D, tethered) 1560, 1562, 1660, 1661 (1D, cordless) 1504, 1704 (2D, tethered) 1564, 1664 (2D, cordless) Version 1.30

More information

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication

More information

Chapter 1 Introduction 2. Chapter 2 Barcode Symbologies 3. Chapter 3 Quick Start 4

Chapter 1 Introduction 2. Chapter 2 Barcode Symbologies 3. Chapter 3 Quick Start 4 WWS100i Table of Contents Chapter 1 Introduction 2 Chapter 2 Barcode Symbologies 3 Chapter 3 Quick Start 4 Chapter 4 WWS550i Setup & Configuration 6 1. Setup & Configuration 6 2. Factory Default and Autosense

More information

User's Guide. Using RFDBManager. For 433 MHz / 2.4 GHz RF. Version 1.23.01

User's Guide. Using RFDBManager. For 433 MHz / 2.4 GHz RF. Version 1.23.01 User's Guide Using RFDBManager For 433 MHz / 2.4 GHz RF Version 1.23.01 Copyright Notice Copyright 2005 Syntech Information Company Limited. All rights reserved The software contains proprietary information

More information