Index...1. Introduction...3. Installation- Keyboard Wedge...3 RS USB...3. Default Setting for each barcode shown as below:...
|
|
|
- Asher Green
- 9 years ago
- Views:
Transcription
1 Index Index...1 Introduction...3 Installation- Keyboard Wedge...3 RS USB...3 Default Setting for each barcode shown as below:...4 Programming the MS Interface Selection...7 Keyboard wedge...8 RS Scan...16 Indication...20 UPCA...22 UPCE...25 EAN EAN Code Interleaved 2 of Industrial 2 of Matrix 2 of 5 Eur...44 Codabar...46 Code Code Code MSI/plessey
2 UK/plessey...62 Telepen...60 Standard 2 of China Post...64 Italian Pharmacy Code...66 PDF String setting...71 Transmission...74 Test Chart...78 CODABAR-PARA...78 CODE-11 PARA...78 CODE-128 PARA...78 CODE-39 PARA...78 CODE-93 PARA...78 EAN-13 PARA...78 STANDARD-25 PARA...79 EAN-8 PARA...79 INDUSTRIAL-25 PARA...79 UPCE PARA...79 INTERLEAVED-25 PARA...79 MATRIX 25 PARA...80 MSI/PLESSEY PARA...80 UPCA PARA...80 UK/PLESSEY PARA...80 PDF Parameter Setting List
3 Introduction Installation- Keyboard Wedge 1) First of all, you must switch off power for the terminal/computer. 2) Disconnect the keyboard cable from the back of the terminal/computer. 3) Connect the appropriate interface cable to the scanner and to the terminal/computer. 4) Turn the terminal/computer power on. RS-232 1) Disconnect power to the terminal/computer. 2) Connect the appropriate interface cable and external power supply (DC adapter) to the scanner. 3) Plug the serial connector into the serial port on the back of your computer/terminal. Tighten the two screws to secure the connector to the port. 4) Plug the power pack into power source. 5) Once the scanner has been fully connected, turn the terminal/computer power back on. USB - USB (Simulate with Keyboard wedge) 1) Connect the USB cable between scanner and PC. 2) Windows will automatically detect the USB device. Note: If any of the above operation is incorrect, turn off the power immediately and checking any improper connections. Go through all above steps again. 3
4 Default Setting for each barcode shown as below: Code Type Read MS320 Checksum Checksum Code Verification Transmission ID UPC-A V V V A UPC-E V V V E EAN-13 V V V F EAN-8 V V V FF Code-39 V * Interleaved 2 of 5 V V i Industrial 2 of i Matrix 2 of 5 B Codabar % Code-128 V V # Code-93 V & Code-11 V One digit O MSI/Plessey UK/Plessey Telepen S Standard 2 of i China Post t Italian Pharmacy p Code. PDF417 V 4
5 Programming the MS320 To program the MS320, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented. To program each option, you must: 1. Scan the Program barcode on the parameter setting part. 2. Enter the option mode by scanning the Option Bar Code (also on the Parameter setting part). 3. To the right of the option barcode, the necessary alphanumeric inputs are listed. Scan these alphanumeric entries from the back fold out page. To confirm above steps, you must scan the Finish barcode on the back fold out page. 4. Once you have finished programming. Scan the Exit barcode, listed on the lower right hand corner of each parameter setting part. 5
6 Program Barcode Program Option Bar Code Option Alphanumeric Entry Keyboard Wedge Interface RS-232 selection USB 03 Keyboard/RS Auto detection reserved 05 Exit Option Barcode Exit Barcode Back Fold Out Finish barcode 6
7 Interface Selection This decoder build-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, and the latest USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface. Interface selection: You can change factory interface default for other type interface. By plugging different cables, setting right interface, then the scanner will be changed to another interface. However, you must make sure which cable you need. Keyboard/RS232/UBS Auto detection: By setting this function, it will automatically select the Keyboard wedge or RS-232 or UBS interface for user. Program Option Bar Code Option Alphanumeric Entry Interface selection Keyboard Wedge RS-232 USB Keyboard /RS232/USB Auto detection Reserved * 05 Note:*-Default Exit 7
8 Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard Type: Select keyboard type connector of your host computer. Scanner must be selected to the appropriate host interface cable converter. Program Option Bar Code Option Alphanumeric Entry Keyboard type IBM AT, PS/2 Reserved Reserved Reserved Reserved Reserved Reserved Exit 8
9 Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command keyb to select the desirable keyboard layout or in WINDOWS entry Control then pops Keyboard to select country at language item. For details, please refer to your DOS or WINDOWS user s manual. Keyboard Speed: By selecting, you can change output speed of scanner to match with host computer. Generally, set 00 or in working high speed. If some output characters of barcode have been lost, you may need to set 05 or 06 to match your host keyboard speed. Function Key: Set, scanner can output code as pressing function-key in your application program while the barcode datas contain ASCII value between 16 to 1F16. Refer to ASCII table, page 94. Numeric Key: The Keypad has to be selected if your application program is only keypad numeric code acceptable. So, scanner will output code as press numeric keypad when it read numeric digit. (The keypad is in the right side of keyboard, and Num Lock control key is also on.) If Alt+Keypad is selected, Caps Lock and output will be independent. Program Option Bar Code Option Alphanumeric Entry 9
10 Keyboard layout Keyboard speed Function key Numeric key USA Belgium Danish France Germany Italian Portuguese Spanish Swedish Switzerland UK Latin American : high clock rate 8 : low clock rate Alphabetic key Numeric keypad (Num lock state only) Alt+Keypad * 00 * Exit
11 Keyboard wedge Caps Lock: By selecting Caps Lock or No Caps Lock, scanner can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present status to the PC during power-on. Inter-character delay: This delay is inserted after each data characters transmitted. If the transmission speed is too high, the system may not be able to receive all characters. Adjust it and try out suited delay to make system work properly. Block transmission delay: It is a delay timer between barcode data output. The feature is used to transfer continually with shorter barcode data or multi-field scanning. 11
12 Program Option Bar Code Option Alphanumeric Entry Caps lock ON Caps lock OFF 00 * Caps lock Power-on simulation msec * Inter-character delay msec * Block transmission delay Exit 12
13 RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 1116) Xoff: Transmit Off (ASCII Code1316) Flow control: None-The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol. RTS/CTS-If the scanner wants to send the barcode data to host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication. If there is no replied CTS signal from the host computer after the timeout (Response Delay) duration, the scanner will issue a 5 warning beeps. Xon/Xoff- When the host computer is unable to accept data, it sends a Xoff code to inform the scanner to suspend data transmission, and Xon to continue. ACK/NAK- When the ACK/NAK protocol is used, the scanner waits for an ACK (acknowledge) or (not acknowledge) from the host computer after data transmission, and will resend in response to a NAK. Inter-character delay: It is delay time between data character s data output. It is also same as Inter-char. delay of keyboard wedge. Block transmission delay: It is a delay time between barcode data output. It is also same as Block transmission delay of keyboard wedge. 13
14 Response delay: This delay is used for serial communication of the scanner to waiting for handshaking acknowledgment from the host computer. Program Option Bar Code Option Alphanumeric Entry Flow control None RTS/CTS Xon/Xoff ACK/NAK (msec) Inter-character delay (10 msec) Block transmission delay (100 msec) * Response delay Exit 14
15 Program Option Bar Code Option Alphanumeric Entry Baud rate Parity Data bit Stop bit 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS BPS BPS None Odd Even 8 bits 7 bits One bit Two bits * Exit 15
16 Scan Scanning mode: Good-read off-the trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning. Alternate-The trigger button acts as a toggle switch. Press button to activate or stop scanning. Timeout off-the trigger button must be pressed to activate scanning, and scanner stops scanning when no code is decoded after the Stand-by duration elapsed. Continue-The scanner always keeps reading, and it does not matter when trigger button is pressed or duration is elapsed. Same Barcode delay time: If the barcode has been scanned twice, then only the first barcode will be accepted. Double confirm: If it is enabled, the scanner will require a several times successful decoding to confirm the barcode data. The more confirming times required the more inhibitive miss-reading code will be shown. If you set Double confirm, the Multi field scan function won t be able to work. 16
17 Program Option Bar Code Option Alphanumeric Entry Scanning mode Good-read off Momentary Alternate Timeout off Continue 00 * (second) * Stand-by duration -99 (10 msec) * Same barcode delay time (00: no double Double confirm confirm) Exit 17
18 Scan Multi field scan: The scanner can be read many sets of barcode data on the same scanning line at the same time, even if they are different kinds of barcode symbology. Global min./max. code length: Global Minimum and Maximum length can be set to qualify data entry. The length is defined as the actual barcode data length to be sent. Label with length exceeds these limits will be rejected. Make sure that the Minimum length setting is no greater than the Maximum length setting, or otherwise the labels of the symbology will not be readable. In particular, you can set the same value for both Minimum and Maximum reading length to force the fixed length barcode decoded. The values of setting have no effect on certain symbologies with fixed length. Notes 1): Please set the min/max length if you have special demand for individual barcode. 2): Include the Check sum digits if you want to set Global min/max code length. Inverted image scan:. Set d the scanner will scan both black/white barcode with white/black background. CTS trigger: This operation enabled an external device to control scanning. The CTS trigger is controlled by apply an external trigger signal to the CTS input. When active, this signal causes scanning to begin as the scanner s trigger was depressed. Position indication: This function can indicate the specific location before scanning. You can also set up the time of indication Program Option Bar Code Option Alphanumeric Entry 18
19 Multi field scan * Global min. code length * Global max.code length Inverted image scan CTS trigger Position indication 30 second 60 second 90 second 120 second 150 second 180 second Continue Exit
20 Indication Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self-test. Exit LED indication: After each successful reading, the LED above the scanner will light up to indicate a good barcode reading. Buzzer indication: After each successful reading, the scanner will beep buzzer to indicate a good barcode reading, and its Beep loudness, Beep tone freq. and Beep tone duration are adjustable. Beep loudness/beep tone freq./beep tone duration: You can adjust Beep Loudness, Beep tone and Beep duration for a good reading upon favorite usage. 20
21 Program Option Bar Code Option Alphanumeric Entry 00 * Power on alert 00 * LED indication 00 * Buzzer indication * Beep loudness (100Hz) * Beep tone freq (10 msec) * Beep tone duration 21 Exit
22 UPCA Read: Format Leading Data Digits Check Zero (11 Digits) Digit Check-sum transmission: By setting, checks sum will be transmitted. Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero. It will beep instead of reading anything when the truncate value is more than the barcode data digits or the value of Truncate Leading is overlapped with that of the Ending. The maximum value of truncate digits is 15. Code ID setting: Code ID setting is a character used to represent the symbol upon a succeeding reading. A Code ID setting is prefixed to the data begin or end transmitted if the feature is selected. If you want application to transmit Code ID, you must set Code ID transmission to first. Refer to Code ID transmission. Insertion group selection: The scanner offer one or two insertion group for own symbology. By setting one or two digits to indicate which insertion group you want to insert. You may refer to Character insertion. Example: Group 2 set 02 or 20. Group 1 and 4 set 14 or 41. Program Option Bar Code Option Alphanumeric Entry 00 * Read 22
23 00 * Check-sum verification 00 * Check-sum transmission * Max.code length * Min.code length Truncate leading Truncate ending 00-ffH ASCII code 00-ffH < A >* Code ID setting Insert group selection 23 Exit
24 UPCA Supplement digits: The Supplement digits barcode is the supplemental 2 or 5 characters for WPC code. Format Supplement Digits Leading Data Digits Check 2 or 5 or Zero (11 Digits) Digit UCC / EAN 128 Truncate Leading zero: The leading 0 digits of UPCA data characters can be truncated when the function is enabled. Program Option Bar Code Option Alphanumeric Entry Supplement digits Truncate Leading zero None 2 digits 5 digits UCC/EAN 128 Auto detection * The Exit 24
25 UPCE Read: Format Leading Zero Data Digits (6 Digits) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check-sum transmission: By setting, checks sum will be transmitted. Program Option Bar Code Option Alphanumeric Entry 00 * Read 00 * Check-sum verification 00 * Check-sum transmission 25 Exit
26 UPCE Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Leading Data Digits Zero (6 Digits) Check Digit Supplement Digits 2 or 5 or UCC/EAN 128 Truncate Leading zero: Refer to Truncate Leading zero of UPCA. Expansion: The expansion function is used only for UPCE and EAN-8 code reading. It extends to 13-digits with 0 digits when the feature is enabled. Example: Barcode Output: Program Option Bar Code Option Alphanumeric Entry Truncate leading 26
27 Truncate ending 00-ffH ASCII code 00-ffH < E >* Code ID setting Insert group selection Supplement digits Truncate Leading zero Expansion None 2 digits 5 digits UCC/EAN 128 Auto detection Exit 27
28 EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check-sum transmission: By setting, checks sum will be transmitted. Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is zero, the Global Min./Max. Code Length is in effect. The length is defined as to the actual barcode data length to be sent. Label with length exceeds these limits will be rejected. Make sure that the Minimum length setting is no greater than the Maximum length setting, or otherwise all the labels of the symboblogy will not be readable. In particular, you can see the same value for both Minimum and Maximum reading length to force the fixed length barcode decoded. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Program The Option Bar Code Option Alphanumeric Entry 00 * Read 28
29 00 * Check-sum verification 00 * Check-sum transmission * Max.code length * Min.code length Truncate leading Truncate ending Exit 29
30 EAN-13 Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Data Digits (12 Digits) Check Digits Supplement Digits 2 or 5 or UCC / EAN 128 ISBN/ISSN: The ISBN (International Standard Book Number) and ISSN (International Standard Serial Number) are two kinds of barcode for book and magazines. The ISBN is 10 digits with leading 978 and the ISSN is 8 digits with leading 977 of the EAN-13 symbobolgy. Example: Barcode Output: Example: Barcode Output: Program Option Bar Code Option Alphanumeric Entry 00-ffH ASCII code 00-ffH < F >* Code ID setting Insert group 30
31 selection Supplement digits ISBN/ISSN conversion None 2 digits 5 digits UCC/EAN 128 Auto detection Exit 31
32 EAN-8 Read: Format Data Digits Check (7 Digits) Digits Check-sum verification: The checksum of EAN-8 is optional and made as the sum of the numerical value of the data digits. Check-sum transmission: By setting, checks sum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of EAN-13. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry 00 * Read 00 * Check-sum verification 32
33 00 * Check-sum transmission * Max.code length * Min.code length Truncate leading Truncate ending Two characters 00-ffH ASCII 00-ffH, 00-ffH < FF >* Code ID setting code Insert group selection 33 Exit
34 EAN-8 Supplement digits: Format Supplement Digits Data Digits Check 2 or 5 or (7 Digits) Digits UCC/EAN 128 Truncate Leading zero: Refer to Truncate Leading zero of UPCE. Expansion: Refer to Expansion of UPCE. Program Option Bar Code Option Alphanumeric Entry Supplement digits Truncate Leading zero Expansion None 2 digits 5 digits UCC/EAN 128 Auto detection Exit 34
35 Code 39 Read: Format Start Data Digits Checksum End ( Variable) (Optional) Check-sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check-sum transmission: By setting, checksum and will be transmitted. Program Option Bar Code Option Alphanumeric Entry 00 * Read Check-sum verification Check-sum transmission 35 Exit
36 Code 39 Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is zero, the Global Min./Max. Code Length is in effect. The length is defined as to the actual barcode data length to be sent. Label with length exceeds these limits will be rejected. Make sure that the Minimum length setting is no greater than the Maximum length setting, or otherwise all the labels of the symboblogy will not be readable. In particular, you can see the same value for both Minimum and Maximum reading length to force the fixed length barcode decoded. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z). Program Option Bar Code Option Alphanumeric Entry 36
37 Max. code length Min. code length Truncate leading Truncate ending 00-ffH ASCII code 00-ffH <*> Code ID setting Insert group selection Standard Full ASCII Format Exit 37
38 Code 39 Append: This function allows several symbols to be concatenates and be treat as one single data entry. The scanner will not transmit the embedded appending code (space for Code-39). If and other symbols were read again with the appended code, then codes will be transmitted without Code ID, Preamble and Prefix. When a symbol was decoded without the appended code, the data will be transmitted without Code ID and Prefix, but the Postamble Suffix codes are appended. This function is used when the first number of code 39 is a space. Example: Start/end transmission: The start and end characters of Code-39 are. You can transmit all data digits including two. Program Option Bar Code Option Alphanumeric Entry Append Start/end transmission 38 Exit
39 Interleaved 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting, checksum and will be transmitted. Program Option Bar Code Option Alphanumeric Entry 00 * Read 00 * Check-sum verification Check-sum transmission 39 Exit
40 Interleaved 2 of 5 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Max. code leading Min. code leading Truncate leading Truncate ending 40
41 00-ffH ASCII code 00-ffH < i >* Code ID setting Insert group selection Exit 41
42 Industrial 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Read Max. code length Min. code length 42
43 Truncate leading Truncate ending 00-ffH ASCII code 00-ffH < i >* Code ID setting Insert group selection Exit 43
44 Matrix 2 of 5 Eur Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting, checksum and will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Read Checksum Verification 44
45 Checksum Transmission Max. code length Min. code length Truncate leading Truncate ending 00-ffH ASCII code 00-ffH < B >* Code ID setting Insert group selection 45 Exit
46 Codabar Read: Format Start Data Digits (Variable) Checksum (Optional) End Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Transmission: By setting, checksum and will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Program Option Bar Code Option Alphanumeric Entry Read Checksum Verification 46
47 Checksum Transmission Max. code length Min. code length Truncate leading Truncate ending 00-ffH ASCII code 00-ffH < % >* Code ID setting Exit 47
48 Codabar Insertion group selection: Refer to Insertion group selection of UPCA. Start/End type: The Codabar has four pairs of Start/End pattern; you may select one pair to match your application. Start/End Transmission: Refer to Start/End Transmission of Code 39. Program Option Bar Code Option Alphanumeric Entry Insert group selection Start/End type Start/End transmission ABCD/ABCD abcd/abcd ABCD/TN*E Abcd/tn*e Exit
49 Code-128 Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 103 of all data digits. Checksum Transmission: By setting, checksum and will be transmitted. Program Option Bar Code Option Alphanumeric Entry 00 * Read 00 * Checksum Verification Checksum Transmission 49 Exit
50 Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Format: The Code-128 can be translated to UCC/EAN-128 format if it starts with FNC1 character. The first FNC1 will be translated to ]C1,and next to be a field separator code as <GS>(1D16). ]C1 Datas <GS> Datas Checksum Append: When the function is enabled, it won't show the data immediately if scanner read the barcode includes FNC2 code. It will show all data until it read the barcode, which doesn't have FNC2 code. Field separator code: This feature is only used for UCC/EAN-128 format. This Field separator code means you can reassign second or after a FNC1 for your usage. The default of ASCII code is <GS>(1D16). Program Option Bar Code Option Alphanumeric Entry Max. code length Min. code length 50
51 Truncate leading Truncate ending 00-ffH ASCII code 00-ffH < # >* Code ID setting Insert group selection Standard UCC/EAN-128 Format Append 00-ffH ASCII code 00-ffH < # >* UCC/EAN-128 ID setting 00-ffH ASCII code 00-ffH 1DH* Field separator code 51 Exit
52 Code-93 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting, checksum and will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Read (two 00 * Checksum digits) Verification 52
53 Checksum Transmission Max. code length Min. code length Truncate leading Truncate ending 00-ffH ASCII code 00-ffH < & >* Code ID setting Insert group selection 53 Exit
54 Code-11 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Read Checksum Verification One digit Two digits 00 * 02 54
55 Checksum Transmission Max. code length Min. code length Truncate leading Truncate ending 00-ffH ASCII code 00-ffH < O >* Code ID setting Insert group selection 55 Exit
56 MSI/plessey Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Read Checksum Verification Mod 10 Mod 10/10 Mod 11/10 56 (8110) *(8150/8210) 02 03
57 Checksum Transmission Max. code length Min. code length Truncate leading Truncate ending 00-ffH ASCII code 00-ffH >* Code ID setting Insert group selection 57 Exit
58 UK/plessey Read: Format Data Digits Checksum1+2 (Variable) (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Read 00 * Checksum Verification 58
59 Checksum Transmission Max. code length Min. code length Truncate leading Truncate ending 00-ffH ASCII code 00-ffH >* Code ID setting Insert group selection 59 Exit
60 Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Read Checksum Verification Checksum 60
61 Transmission Max. code length Min. code length Truncate leading Truncate ending 00-ffH ASCII code 00-ffH < S >* Code ID setting Insert group selection Numeric only Full ASCII only Format 61 Exit
62 Standard 2 of 5 Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Read Max. code length Min. code length 62
63 Truncate leading Truncate ending 00-ffH ASCII code 00-ffH < i >* Code ID setting Insert group selection Exit 63
64 China Post Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Read * Max. code length * Min. code length 64
65 Truncate leading Truncate ending 00-ffH ASCII code 00-ffH < t >* Code ID setting Insert group selection Exit 65
66 Italian Pharmacy Code Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Leading A : If this function is enabled, each prefix of data shall be A. Program Option Bar Code Option Alphanumeric Entry Read * Max. code length 66
67 * Min. code length Truncate leading Truncate ending 00-ffH ASCII code -ffh < p >* Code ID setting Insert group selection Leading A Exit 67
68 PDF-417 Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Program Option Bar Code Option Alphanumeric Entry 00 * Read Truncate leading Truncate ending Exit 68
69 PDF-417 Only the MS320 can decode PDF-417. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry 00-ffH ASCII code 00-ffH < >* Code ID setting Insert group selection *QAJ* Escape sequence transmit Exit 69
70 String setting Prefix characters: Up to 22 ASCII characters may be sent before data digits. Prefix Data Digits Suffix Suffix characters: Up to 22 ASCII characters may be sent after data digits. Preamble/ Postamble characters: They are appended to the data automatically when each barcode is decoded. Example: Add a prefix/suffix or preamble/postamble for all symbologies. In this example, you are sending a $ symbol as a prefix for all symbologies. Steps: 1) Scan Programming and Prefix characters setting barcode. 2) Use the ASCII code table to find the value of $ 24. 3) Scan 2 and 4 from the barcode on the fold out back page. 4) Scan Finish from the barcode on the fold out page. 5) Scan Exit barcode. Program Option Bar Code Option Alphanumeric Entry None 1-22 characters 00-ffH ASCII Prefix characters code setting None 1-22 characters 0D* 00-ffH ASCII Suffix characters code setting 70
71 None 1-22 characters 00-ffH ASCII Preamble characters code setting None 1-22 characters 00-ffH ASCII Postamble code characters setting None 1-22 characters 00-ffH ASCII Insert G1 characters code setting None 1-22 characters 00-ffH ASCII Insert G2 characters code setting None 1-22 characters 00-ffH ASCII Insert G3 characters code setting None 1-22 characters 00-ffH ASCII Insert G4 characters code setting 71 Exit
72 String setting Insert G1/G2/G3/G4 character setting: The scanner offer 4 positions and 4 characters to insert among the symbol. Example: Barcode Output- Barcode 1 2 A B 3 4 C D 5 6. Steps: 1) Scan Programming and Insert G1 characters setting barcode. 2) Use the ASCII code table to find the value of A 41,B 42. 3) Scan 4, 1 and 4, 2 from the barcode on the fold out back page. 4) Scan Finish from the barcode on the fold out page. 5) Repeat the same procedure in Insert G2 characters setting. 6) Scan Exit barcode. 7) Insert data group 1-4 position. Please refer to Chapter- Transmission, page 65 and in specific barcode that you want to use. Program Option Bar Code Option Alphanumeric Entry None 1-22 characters 00-ffH ASCII Insert G1 characters code setting None 1-22 characters 00-ffH ASCII Insert G2 characters code setting 72
73 None 1-22 characters 00-ffH ASCII Insert G3 characters code setting None 1-22 characters 00-ffH ASCII Insert G4 characters code setting Exit 73
74 Transmission Preamble transmission: By setting, Preamble will be appended before the data transmitted. Postamble transmission: By setting, Postamble will be appended after the data is transmitted. Insert data group 1-4 position: The scanner offers 4 positions to insert among the symbol. The position default value is 00 to indicate no character insertion. Beside, make sure insertion positions are not greater than the symbols; otherwise the insertion data is not effective. Code ID position: Upon your usage, the transmitting position of Code ID can be selected to place Before Code Data or After Code Data when it is transmitted. Program Option Bar Code Option Alphanumeric Entry Preamble transmission Postamble transmission 74
75 00-64 (00: no insertion) Insert data group 1 position (00: no insertion) Insert data group 2 position (00: no insertion) Insert data group 3 position (00: no insertion) Insert data group 4 position Before code data After code data Code ID position Exit 75
76 Transmission Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM ID. Code length transmission: A number of data digits can be transmitted before the code data when is selected. The total length of the barcode is the number of barcode data except Truncate Leading/Ending Digits. And the length is a number with two digits. Code name transmission: This function is to show unknown barcode symbologies that include all readable symbologies of the scanner. When is selected, Code Name will be transmitted before code data, you will know what kind of barcode symbology is. Case conversion: Under the barcode, you can set the alphabet in either upper case or lower case. Program Option Bar Code Option Alphanumeric Entry Code ID transmission Proprietary ID AIM ID 02 76
77 Code length transmission Code name transmission Case conversion Upper case Lower case *For barcode data only 02 Exit Format of barcode data transmission: Prefix Name Preamble ID Code Length Barcode data ID Postamble Suffix Insert groups 77
78 Test Chart CODABAR-PARA CODE-11 PARA CODE-128 PARA CODE-39 PARA CODE-93 PARA EAN-13 PARA 78
79 STANDARD-25 PARA EAN-8 PARA INDUSTRIAL-25 PARA UPCE PARA INTERLEAVED-25 PARA 79
80 MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA UK/PLESSEY PARA PDF417 Unitech best performing long range CCD scanner MS year warranty 80
81 ASCII Code Table Note: For keyboard wedge only. L H Null NUL DLE 1 Up F1 SOH DC1 2 Down F2 STX DC2 3 Left F3 ETX DC3 4 Right F4 EOT DC4 5 PgUp F5 ENQ NAK 6 PgDn F6 ACK SYN 7 F7 BEL ETB 8 Bs F8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl+ SO RS F Delete Alt+ SI US L H SP P ` p 1! 1 A Q a q 2 2 B R b r 3 # 3 C S c s 4 $ 4 D T d t 5 % 5 E U e u 6 & 6 F V f v 7 7 G W g w 8 ( 8 H X h x 9 ) 9 I Y i y A : J Z j z B + ; K [ k { C, < L \ l D - = M ] m } E. > N ^ n F /? O _ o DEL 81
82 Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current configuration of your MS-320, scanner over the host terminal/computer, scan the Barcode standard parameter setting list bar code. Unique parameter list If you wish to display the unique parameter setting list, scan the unique parameter list bar code System parameter setting list If you wish to display the product information and revision number for your MS-320 scanner over the host terminal/computer, scan the System parameter setting list bar code. String setting list If you wish to display the string format list, scan the String setting list bar code. 82
83 Firmware version list If you wish to display the firmware version, scan the Firmware version list. WARNING: Default value initialization If you wish to return the MS-320 to all the factory default settings, scan the Default value initialization bar code. Exit 83
84 Index 0 A 1 B C D E F Finish
NOTICE: respective owner. Note: Specification is subject to changes without. notice.
0 NOTICE: This device complies with Part 15 of the FCC Rules. Operation shall be subject to the following two conditions: (1) This device may not cause harmful interface, and (2) This device must accept
Xi2000 Series Configuration Guide
U.S. Default Settings Sequence Reset Scanner Xi2000 Series Configuration Guide Auto-Sense Mode ON UPC-A Convert to EAN-13 OFF UPC-E Lead Zero ON Save Changes POS-X, Inc. 2130 Grant St. Bellingham, WA 98225
BARCODE READER V 2.1 EN USER MANUAL
BARCODE READER V 2.1 EN USER MANUAL INSTALLATION OF YOUR DEVICE PS-2 Connection RS-232 Connection (need 5Volts power supply) 1 INSTALLATION OF YOUR DEVICE USB Connection 2 USING THIS MANUAL TO SETUP YOUR
Barcode Magstripe. Decoder & Scanner. Programming Manual
Barcode Magstripe Decoder & Scanner Programming Manual CONTENTS Getting Started... 2 Setup Procedures... 3 Setup Flow Chart...4 Group 0 : Interface Selection... 5 Group 1 : Device Selection for keyboard
MD6 Series 2D Barcode Scanner
MD6 Series 2D Barcode Scanner User Manual Version: MD6_UM_EN_V1.1.9 2 Warning: Ensure that the optional DC adapter works at +5V, especially for the RS-232 interface cable. NOTICE: 1. All software, including
MK-SERIE 1000/1500/2000 AllOfBarcode.de Michael Krug - 83278Traunstein BARCODE SCANNER
MK-SERIE 1000/1500/2000 AllOfBarcode.de Michael Krug - 83278Traunstein BARCODE SCANNER Configuration Guide - 1 - Table of Contents Chapter 1 System Information 1.1 About this manual 3 1.2 How to set up
Part No. : MUL-53221-07 PROGRAMMING GUIDE
Part No. : MUL-53221-07 PROGRAMMING GUIDE PROGRAMMING GUIDE for BARCODE SCANNERS The guide can be used as keyboard emulation, RS- 232C serial interface, and USB 1.1 interface and wand emulation. IMPORTANT
Scanner Configuration
Scanner Configuration SmartScan Manual DOC Version 2.21 This document is specifically designed for the user to print two pages per sheet of paper with optimal print quality. Copyright 2005~ 2008 CIPHERLAB
Bar Code CCD Scanner OPERATION MANUAL
ISO 9002 Certified Lead with technology Win customers with service Bar Code CCD Scanner OPERATION MANUAL 69 Jarltech International Inc. 1998. All rights reserved. Under the copyright laws, this manual
Enter/Exit programming
P/N: MUL-53247-02 Enter/Exit programming (This barcode is also found at back cover page.) Framed values are default values. All Rights Reserved This guide is designed for advanced settings of Hand Free
BI-300. Barcode configuration and commands Manual
BI-300 Barcode configuration and commands Manual 1. Introduction This instruction manual is designed to set-up bar code scanner particularly to optimize the function of BI-300 bar code scanner. Terminal
QuickScan QS6500/QS6500BT
QuickScan QS6500/QS6500BT Product Reference Guide PSC Inc 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents
Voyager 9520/40 Voyager GS9590 Eclipse 5145
Voyager 9520/40 Voyager GS9590 Eclipse 5145 Quick Start Guide Aller à www.honeywellaidc.com pour le français. Vai a www.honeywellaidc.com per l'italiano. Gehe zu www.honeywellaidc.com für Deutsch. Ir a
Product Reference Guide. QuickScan TM QS6500/QS6500BT. General Purpose Handheld Linear Imager Bar Code Reader with Bluetooth Wireless Technology
QuickScan TM QS6500/QS6500BT General Purpose Handheld Linear Imager Bar Code Reader with Bluetooth Wireless Technology Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402
Laser Barcode Scanner
Laser Barcode Scanner User s Manual FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
QuickScan QS2500 Handheld Bar Code Scanner. Product Reference Guide
QuickScan QS2500 Handheld Bar Code Scanner Product Reference Guide PSC Inc 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved.
E-i. Section E. Code Formatting. E/D = Enable/Disable T/DNT = Transmit/Do Not Transmit EX/DNEX = Expand/Do Not Expand
Section E Code Formatting E/D = Enable/Disable T/DNT = Transmit/Do Not Transmit EX/DNEX = Expand/Do Not Expand C/DNC = Convert/Do Not Convert E/DNE = Enable/Do Not Enable T/DNT UPC-A Check Digit (E - 1)
QuickScan i. QD2100 Barcode Imager. Product Reference Guide
QuickScan i QD2100 Barcode Imager Product Reference Guide Configuring the Interface KEYBOARD FEATURES AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/standard Key Encoding Select KBD-AT Keyboard
HANDHELD LASER SCANNER
HANDHELD LASER SCANNER PROGRAMMING GUIDE PSC Scanning, Inc. En Suisse: 959 Terry Street GOMARO s.a. Eugene, Oregon 97402-9120 1123 Aclens - Switzerland Telephone: (541) 683-5700 http://www.gomaro.ch/ Toll
Laser Barcode Scanner User s Manual
Laser Barcode Scanner User s Manual FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
Barcode Scanning Made Easy. Programming Guide
Barcode Scanning Made Easy Programming Guide CCD Scanner Programming Guide Please Read Note: The Wasp WCS3900 Series Scanners are ready to scan the most popular barcodes out of the box. This manual should
Allen-Bradley. Bar Code. 2-D Hand-Held. Programming Guide. Bar Code. Scanners. (Cat. No. 2755-HTG-4)
Allen-Bradley 2-D Hand-Held Bar Code Scanners Bar Code Programming Guide (Cat. No. 2755-HTG-4) Important User Information The illustrations, charts, sample programs and layout examples shown in this guide
Product Reference Guide
PowerScan 7000 SRI Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part
Barcode Scanning Made Easy. WWS500 Programming Guide
Barcode Scanning Made Easy WWS500 Programming Guide Table of Contents Chapter 1. Introduction...........................2 Chapter 2. Barcode Symbologies...................3 Chapter 3. Quick Start............................4
MK-5200 2D Imager Barcode Scanner Configuration Guide
MK-5200 2D Imager Barcode Scanner Configuration Guide V 1.2 Programming the Engine Code Programming On/Off Read the barcode to activate Code Programming function. One or more Code Programming barcodes
BARCODE IMAGER. Programming Manual International Edition, Rev. A1
BARCODE IMAGER International Edition, Rev. A Revision History Rev. No. Released Date Description Rev.. Beta Aug., 8 First Release Rev.. Beta Aug., 8 Page 9 Vibrator Default value is changed from Disable
S302D. Programming Guide. 2D Imaging Barcode Scanner. Advanced Handheld High-Speed Laser Scanner
S302D 2D Imaging Barcode Scanner Programming Guide 1 Advanced Handheld High-Speed Laser Scanner Revision History Changes to the original manual are listed below: Version Date Description of Version 1.0
MS100 Bar Code Pen Reader
MS100 Bar Code Pen Reader AdventureJan General Advisory Improper handling, storage, environmental influences and /or product modification can lead to problems during use. This is particularly true if repairs
CD-3860 Bar Code Scanner User s Manual
CD-3860 Bar Code Scanner User s Manual Important Notice Rev. Original No warranty of any kind is made in regard to this material, including, but not limited to, implied warranties of merchantability or
METROLOGIC INSTRUMENTS, INC. MetroSelect Configuration Guide
METROLOGIC INSTRUMENTS, INC. MetroSelect Configuration Guide Copyright 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form
Barcode reader setup manual
Barcode reader setup manual Setup procedures are as follows: 1 Scan Begin setting 2 Scan your required function and its corresponding barcode 3 Scan End setting 4 All the setting parameters will be saved
HAND-HELD DEVICES II. Software Configuration Manual
HAND-HELD DEVICES II Software Configuration Manual HAND-HELD DEVICES II SOFTWARE CONFIGURATION MANUAL DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy Hand-Held Devices
Bar Code Reader Models 1000/1002 USER'S MANUAL 2190 Regal Parkway Euless, TX 76040 (817) 571-9015 (800) 648-4452 FAX (817) 685-6232 FCC NOTICE WARNING: This equipment generates, uses and can radiate radio
TaoTronics Laser Barcode Scanner User s Manual
TaoTronics Laser Barcode Scanner User s Manual SETUP from PC keyboard For KBW or KBW/RS232 interface 1 Features * Simple installation,keyboard Wedge Serial, Wand Emulation tc * Superior keyboard wedge
Enter/Exit Programming Mode
Enter/Exit Programming Mode (This barcode can also be found at back cover page.) Framed values are default values. IMPORTANT NOTICE No warranty of any kind is made in regard to this material, including,
METROLOGIC INSTRUMENTS INC. MetroSelect Single-Line Configuration Guide
METROLOGIC INSTRUMENTS INC. MetroSelect Single-Line Configuration Guide Copyright 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored
Scanner Configuration Manager Manual. for PC type computers
Scanner Configuration Manager Manual for PC type computers TABLE OF CONTENTS 1. SCANNER CONFIGURATION MANAGER......... 1 Start it Up...................... 1 First Look...................... 3 Settings......................
DL910 SERIES. Instruction Manual
DL910 SERIES Instruction Manual DL910 SERIES INSTRUCTION MANUAL ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification. Datalogic shall not
Laser Scanner Programming Guide (SE923 laser engine)
Laser Scanner Programming Guide (SE923 laser engine) CONTENT Technical note... 5 How to recognise the type of the laser barcode engine... 5 How to program the laser barcode reader into default value...
DUET / VS800 Scanner. DUET Scanner VS800 Scanner. Programming Kit
DUET / VS800 Scanner DUET Scanner VS800 Scanner Programming Kit PSC Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Telefax: (541) 345-7140 PSC and the PSC logo are registered
Create!form Barcodes. User Guide
Create!form Barcodes User Guide Barcodes User Guide Version 6.3 Copyright Bottomline Technologies, Inc. 2008. All Rights Reserved Printed in the United States of America Information in this document is
Configure Your FuzzyScan
Configure Your FuzzyScan A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding Before you trying to configure the FuzzyScan, you must refer to the Quick Installation chapter of reading devices
QuickScan Mobile. Reference Manual
QuickScan Mobile Reference Manual Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of
Wireless Laser Barcode Scanner ils 6300BU. User s Manual
Wireless Laser Barcode Scanner ils 6300BU User s Manual FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Barcode Scanner User Manual V6.6.2
Barcode Scanner User Manual V6.6.2 CONTENTS.......................................................................................... 1 1 2 2 3 4 13 14 15 17 17 19 19 20 22 23 23 28 29 33 42 60 65 85 87
Wireless Scanner. User s Manual - MS910 - Version 1.0
Wireless Scanner - MS910 - User s Manual Version 1.0 Table of Contents Chapter 1 Overview... 1 Introducing the MS910... 1 Package Contents... 2 Chapter 2 Installation and Connection... 5 Connecting (Pairing)
MetroSelect. Single-Line Scanner. Configuration Guide
MetroSelect Single-Line Scanner Configuration Guide Disclaimer Honeywell International Inc. ( HII ) reserves the right to make changes in specifications and other information contained in this document
Revision History. Advanced Handheld CCD/Laser Scanner
Revision History Changes to the original manual are listed below: Version Date Description of Version 1.0 September 9, 2010 Initial release 1.1 February 18, 2011 Added Blink mode selections. i Important
Programming Reference Guide HP USB Barcode Scanner
Programming Reference Guide HP USB Barcode Scanner Document Part Number: 430944-002 August 2006 Print this document before setting up the HP USB Barcode Scanner. The document provides the programming bar
MetroSelect Programming Guide. MLPN 2407/December 1998
MetroSelect Programming Guide MLPN 2407/December 1998 Locations: USA Corporate Headquarters Europe Metrologic Instruments, Inc. Metrologic Instruments GmbH 90 Coles Road Dornierstrasse 2 Blackwood, NJ
because we care MS910 Wireless Barcode Scanner Quick Guide Full user s manual is available on the enclosed CD. Version 1.2 400947G
because we care MS910 Wireless Barcode Scanner Quick Guide Full user s manual is available on the enclosed CD. Version 1.2 400947G because we care OUT OF THE BOX INTRODUCTION 2. Trigger 3. LED Indicator
QuickScan TM L QD 2300 Bar Code Scanner
QuickScan TM L QD 2300 Bar Code Scanner Product Reference Guide Datalogic ADC, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 2007-2014 Datalogic ADC, Inc. An
1.1 Notice... 3 1.2 Introduction... 4 1.3 Codes Read... 4 1.4 Installation... 4 1.5 Pin Assignment... 6. Configuration - General
BAR CODE Contents Chapter 1 Description 1.1 Notice... 3 1.2 Introduction... 4 1.3 Codes Read... 4 1.4 Installation... 4 1.5 Pin Assignment... 6 Chapter 2 Configuration - General 2.1 Flow Chart... 8 2.2
Magellan TM 3200VSi. On-Counter Vertical Presentation Scanner. Product Reference Guide
Magellan TM 3200VSi On-Counter Vertical Presentation Scanner Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An
Register your product and get support at www.philips.com/dictation DPM8500. Barcode scanner configuration guide
Register your product and get support at www.philips.com/dictation DPM8500 Barcode scanner configuration guide Table of contents 1 Introduction 5 Operational Parameters 5 Parameter defaults 5 2 Set default
MINIMAG. Magnetic Stripe Reader Keyboard Wedge. User s Manual
MINIMAG Magnetic Stripe Reader Keyboard Wedge User s Manual TM Agency Approved Specifications for subpart B of part 15 of FCC rule for a Class A computing device. Limited Warranty ID TECH warrants to the
Magellan TM 800i. On-Counter Presentation Omnidirectional Bar Code Reader. Product Reference Guide
Magellan TM 800i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541)
PowerScan 7000 2D Imager
PowerScan 7000 2D Imager Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved.
CHAPTER 8 BAR CODE CONTROL
CHAPTER 8 BAR CODE CONTROL CHAPTER 8 BAR CODE CONTROL - 1 CONTENTS 1. INTRODUCTION...3 2. PRINT BAR CODES OR EXPANDED CHARACTERS... 4 3. DEFINITION OF PARAMETERS... 5 3.1. Bar Code Mode... 5 3.2. Bar Code
All brand, product and service, and trademark names are the property of their registered owners.
Copyright 2010 EQUATOR LIMITED All rights reserved. All intellectual property rights are the property of their owners. EQUATOR LIMITED is authorized the right to use the software; it is provided under
Users Manual. QuickBarII Single-Chip Bar Code Decoder
Users Manual QuickBarII Single-Chip Bar Code Decoder REV E Dec. 22, 2009 LIMITED WARRANTY ID TECH warrants to the original purchaser for a period of 12 months from the date of invoice that this product
CCD Programming Guide
CCD Programming Guide Please Read Note: The Wasp CCD Scanner is ready to scan the most popular bar codes out of the box. This manual should only be used to make changes in the configuration of the scanner
BAR CODE 39 ELFRING FONTS INC.
ELFRING FONTS INC. BAR CODE 39 This package includes 18 versions of a bar code 39 font in scalable TrueType and PostScript formats, a Windows utility, Bar39.exe, that helps you make bar codes, and Visual
Touch TD1100 Family General Purpose Corded Handheld Contact Imager Bar Code Reader
Touch TD1100 Family General Purpose Corded Handheld Contact Imager Bar Code Reader Product Reference Guide Datalogic ADC, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541)
Metrologic MS1690 2D Scanner Installation Guide
Metrologic MS1690 2D Scanner Installation Guide Revision 1.0 Revision History 1.0 04/17/2007 Initial Release The latest version of this document can be found in the following places: Internally for Cerner
BCST-20 Barcode Scanner. Instruction Manual. www.inateck.com
BCST-20 Barcode Scanner Instruction Manual www.inateck.com IMPORTANT NOTICE Safety Precaution * DO NOT disassemble the scanner, or place foreign matter into the scanner causing a short circuit or circuit
TAP Interface Specifications
TAP Interface Specifications This Document is for those who want to develop their own paging control software or add an interface for the WaveWare v9 Series Paging Encoder to their existing software applications.
ASCII Code. Numerous codes were invented, including Émile Baudot's code (known as Baudot
ASCII Code Data coding Morse code was the first code used for long-distance communication. Samuel F.B. Morse invented it in 1844. This code is made up of dots and dashes (a sort of binary code). It was
Advanced Handheld High-Speed Laser Scanner
1 Revision History Changes to the original manual are listed below: Version Date of Version 1.0 Jun. 25, 2010 Initial release 1.1 Sep. 07, 2010 Add configuration barcode value. Add settings of Code 11,
SocketScan Software Advanced Programming Guide
SocketScan Software Advanced Programming Guide A guide to help you program symbology and parameter settings for the following Socket barcode scanning products: Secure Digital Scan Card Series 3 CompactFlash
QuickScan L. Barcode Scanner. Advanced Data Formatting (ADF) Guide
QuickScan L Barcode Scanner Advanced Data Formatting (ADF) Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights
Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation
Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions
CT20 Barcode Scanner User Manual
CT20 Barcode Scanner User Manual IMPORTANT NOTICE Safety Precaution * DO NOT disassemble the scanner, or place foreign matter into the scanner cause a short circuit or circuit damage. * DO NOT expose the
QuickScan TM Lite QW2100
QuickScan TM Lite QW2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700
QuickScan TM Lite QW2100
QuickScan TM Lite QW2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide Datalogic ADC, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541)
Programming Menu V3.9
BAR CODE Programming Menu V3.9 Notice The manufacturer shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages in connection with
plc numbers - 13.1 Encoded values; BCD and ASCII Error detection; parity, gray code and checksums
plc numbers - 3. Topics: Number bases; binary, octal, decimal, hexadecimal Binary calculations; s compliments, addition, subtraction and Boolean operations Encoded values; BCD and ASCII Error detection;
Memory is implemented as an array of electronic switches
Memory Structure Memory is implemented as an array of electronic switches Each switch can be in one of two states 0 or 1, on or off, true or false, purple or gold, sitting or standing BInary digits (bits)
LS6300 Lecteur de code-barres laser
WWW.SYMCOD.COM Manuel LS6300 Lecteur de code-barres laser Version: 30/04/2013 Introduction Le lecteur laser Symcod LS6300 est une solution très abordable pour la gestion de vos opérations. Toujours à la
MetroSelect Single Line Configuration Guide. MS9500 Voyager Series i
MetroSelect Single Line Configuration Guide MS9500 Voyager Series i LOCATIONS Corporate Headquarters Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO 90 Coles Road Tel: 856-228-8100 Blackwood,
Set up your personal configuration. Universal menu book. bar code configuration and commands manual
Set up your personal configuration Universal menu book bar code configuration and commands manual Set up your personal configuration Universal menu book bar code configuration and commands manual ver.
2 Advanced Scanner Configuration Guide
2 Advanced Scanner Configuration Guide Table of contents Introduction...4 Operational Parameters...4 Set Default Parameter...7 Default Parameters...7 Beeper Volume...7 Beeper Tone...8 Beeper Frequency
Symbol LS9203. Product Reference Guide
Symbol LS9203 Product Reference Guide Symbol LS9203 Product Reference Guide 72E-71538-03 Revision A February 2007 Motorola, Inc. 2007. All rights reserved. No part of this publication may be reproduced
Model 200 / 250 / 260 Programming Guide
Model 200 / 250 / 260 Programming Guide E-SEEK Inc. R & D Center 9471 Ridgehaven Court #E San Diego, CA 92123 Tel: 858-495-1900 Fax: 858-495-1901 Sales & Marketing 245 Fischer Ave #D5 Costa Mesa, CA 92626
HT580 User Reference Guide. Version 1.0
Version 1.0 NOTICE 1. Li-Ion Battery Pack The HT580 Portable Terminal and the Li-Ion Battery Pack are packaged separately. You will have to install the Battery Pack when you receive your terminal. Please
TMCT-10 Barcode Scanner User Manual. 102, 5661-99 St. Edmonton, AB T6E 3N8 Ph. 780.988.0215 Fax 780.988.0465
TMCT-10 Barcode Scanner User Manual 102, 5661-99 St. Edmonton, AB T6E 3N8 Ph. 780.988.0215 Fax 780.988.0465 IMPORTANT NOTICE Safety Precaution * DO NOT disassemble the scanner, or place foreign matter
METROLOGIC INSTRUMENTS, INC. IS4225 ScanGlove USB Addendum for the MetroSelect Single-Line Configuration Guide
METROLOGIC INSTRUMENTS, INC. IS4225 ScanGlove USB Addendum for the MetroSelect Single-Line Configuration Guide Copyright 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0 Copyright, 1999-2007 Virtual Integrated Design, All rights reserved. 1 Contents: 1. The Main Window. 2. The Port Setup Window. 3.
CipherLab 5100 Time Attendance Utility Manual
CipherLab 5100 Time Attendance Utility Manual K:\Products\Product Technical\BI\BI-PC5100T\CipherLab5100TimeAttendnaceUtilityManual0707-process.doc Page 1 / 13 1 Login A popup form as follows will appear
MIRROR VT/5250 Terminal Emulation
MIRROR VT/5250 Terminal Emulation 9300 / 9400 / 9500CE / 9600 Series Mobile Computers DOC Version 1.12 Copyright 2007~ 2009 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information
User s Manual. Decoding Laser Scanner P/N 063496-003
User s Manual Decoding Laser Scanner P/N 063496-003 Intermec Corporation 6001 36th Avenue West P.O. Box 4280 Everett, WA 98203-9280 U.S. service and technical support: 1-800-755-5505 U.S. media supplies
USER'S GUIDE NUSCAN 2100 Series
BARCODE SCANNER USER'S GUIDE NUSCAN 2100 Series Table of Contents 1. Limited Warranty...1 2. Introduction...2 3. Contents...3 4. Barcode Symbologies...3 5. Product Introduction...3 6. Installation...4
APPENDIX E COMMAND BARCODES
APPENDIX E COMMAND BARCODES Scan command barcode(s) to quickly configure the Socket Bluetooth Cordless Hand Scanner v3 (1D laser versions). By default, the CHS is in HID mode as a Keyboard device. IMPORTANT!
Symbol LS1203. Product Reference Guide
Symbol LS1203 Product Reference Guide LS1203 Product Reference Guide 72E-73953-04 Revision A November 2012 ii Symbol LS1203 Product Reference Guide Motorola Solutions, Inc. All rights reserved. No part
Synergy Controller Application Note 4 March 2012, Revision F Tidal Engineering Corporation 2012. Synergy Controller Bar Code Reader Applications
Synergy Controller Bar Code Reader Applications Synergy Controller with Hand Held Products Bar Code Scanner OCR-A Labeled Part Introduction The value of the ubiquitous Bar Code Scanner for speeding data
NLS-FR20 Series Fixed Mount Barcode Scanner. User Guide
NLS-FR20 Series Fixed Mount Barcode Scanner User Guide Disclaimer 2015 Fujian Newland Auto-ID Tech. Co., Ltd. All rights reserved. Please read through the manual carefully before using the product and
Installing Your POS Hardware
Installing Your POS Hardware! Installing Your Barcode Scanner Remove the scanner from the packing materials. Attach the Y-cable to the scanner. Orient the connector on one end of the Y-cable so it has
MS-3 Laser Scanner. P/N 83-000000 Rev 4
MS-3 Laser Scanner P/N 83-000000 Rev 4 Copyright 2002 by Microscan Systems, Inc., 1201 S.W. 7th Street, Renton, Washington, U.S.A. 98055 (425) 226-5700 FAX: (425) 226-8682 ISO 9001/Certification No. 00-1047