UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)"

Transcription

1

2 UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit( cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit( cfm)

3 UR Heat recovery unit These units allow to extract a certain amount of exhaust air from the room and supply an equivalent quantity of fresh air. A crossflow aluminium plate exchanger assures an efficient heat exchange between exhaust and fresh air: therefore the fresh air is pre-heated or precooled according to the seasons. The supply air is filtered before entering the heat recovery exchanger that is protected with a synthetic filter also at the exhaust air side. The supply air can optionally be re-heated with a hot water coil or with an electric coil. Features 7 sizes are available: UR: standard version UR W: same as standard version and equipped with water heating coil with copper tubes and 3 rows aluminium fins. Not to be used with chilled water UR E: same as standard versions and equipped with electric heating coil with aluminium fins and double safety thermostat Double suction centrifugal fans coupled directly to the electric motors, equipped with adjustable speeds via an electronic control to vary the flow rate G3 class synthetic filter on the air outlet Aluminium plate reheater housed in the condensate tray that is easily removed from the bottom G3 class synthetic filter on the fresh air intake Self-bearing panels made of galvanized plate with injected polyurethane insulation and thickness 0.8 in. Galvanized condensate tray Fans can be inspected from the bottom Filters can be removed from the bottom for cleaning or replacement Two versions available for horizontal and vertical installation (it is not possible to install the cooling coil accessories and silencers for the vertical installation) Electronic Regulator with Slave Application allowing continuous variation of rotation speed and air flow rate 3

4 Accessories BF: Water cooling coil. FGC: Circular flanges. G4: High-efficiency filters on the fresh air intake in class G4. MPW: Module with 4-row water cooling coil and 1-row water post-heating coil. MPX: Module with 4-row water cooling coil and electric post-heating coil with reinforced finned coils. Safety thermostat included. SE: Free-Cooling control dampers. SU: Silencers. Compatibility with the VMF system For further system information please refer to the specific documentation. Compatibility of accessories Horizontal installation: UR 35 UR 55 UR 75 UR 100 UR 150 UR 210 UR 330 BF 35 BF 55 BF 75 BF 100 BF 150 BF 210 BF 330 FGC 1 FGC 2 G4 35 G4 55 G4 75 G4 100 G4 150 G4 210 G4 330 MPW 35 MPW 55 MPW 75 MPW 100 MPW 150 MPW 210 MPW 330 MPX 35 MPX 55 MPX 75 MPX 100 MPX 150 MPX 210 MPX 330 SE 1 SE 2 SE 3 SE 4 SE 5 SU 1 SU 2 SU 3 SU 4 SU 5 Vertical installation: UR 35 UR 55 UR 75 UR 100 UR 150 UR 210 UR 330 FGC 1 FGC 2 G4 35 G4 55 G4 75 G4 100 G4 150 G4 210 G4 330 SE 1 SE 2 SE 3 SE 4 SE 5 4

5 Technical data Mod. UR 35 UR 55 UR 75 UR 100 UR 150 UR 210 UR 330 Air flow cfm Recoverer: Efficiency % 52, ,3 54,4 53,1 52,7 52 Heat capacity recovered Btu/h Cooling capacity recovered Btu/h Output temperature F Fan motor assembly: Fans n Total input power kw 0,30 0,70 0,70 1,12 1,12 2,00 4,00 Fan speed variation continous continous continous continous continous continous continous UR Standard Available static pressure (in-w) UR E UR W Electrical protection IP Insulation class B F F F F F F Filtres: EN779 Classification G3 G3 G3 G3 G3 G3 G3 Efficiency % Water heating coil (UR W): Geometry P2519 P2519 P2519 P2519 P2519 P2519 P2519 Rows n Fin pitch in Frontal surface area ft Heating capacity (1) Btu/h Air output temperature (1) F Heating capacity (2) Btu/h Air output temperature (2) F Heating capacity (3) Btu/h Air output temperature (3) F Electric heating coil (UR E): Heating capacity Btu/h Air side pressure drop inch-water Stages n Air output temperature (air 46.4 F) F Water cooling coil accessory with box to be positioned after the discharge fan: Frontal surface area ft Rows n Cooling capacity (4) Btu/h Air side pressure drop in-water Power supply = 1~ 220V 60Hz (3N~ 460V 60 Hz Performance values refer to the following conditions: - room air temperature 68 F; - ambient air temperature 23 F. (1) air temp F - water temp. 176/158 F (2) tair temp F - water temp. 158/140 F (3) air temp F - water temp. 113/104 F (4) air temp F - HR 50% - water temp. 53.6/44.6 F 5

6 Lay-out (horizontal configuration) Exaust air Supply air Supply air Exaust air Fresh air inlet Return air Return air Fresh air inlet Supply air Return air Exaust air Fresh air inlet Exaust air Fresh air inlet Supply air Return air Warning : the above diagrams refer to the unit in horizontal configuration only. For the vertical configuration, please consult the manual. Dimensions (in) Cod.: SURUY.05 / 1401 Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data. Aermec S.p.A. Via Roma, Bevilacqua (VR) - Italy Tel Telefax

7 NEW URX CF Heat recovery unit with refrigerant circuit. Air flow from 750 to 3,300 m 3 /h. R410A The URX_CF series is the mono-bloc solution designed for the installation requirements typical for public spaces like bars, restaurants, offices, meeting rooms. The URX_CF units combine in one mono-bloc unit, besides the fan, filter, and heat recovery sections, a heat pump refrigerant circuit with scroll compressors of high output and low noise. The supply air is heated or cooled, based on the season, through the heat pump refrigerant circuit located within the unit and charged with refrigerant R410A. All this allows to have a complete unit, with the automatic operation in each season and capable of combining the required space ventilation requirements with efficient heat recovery. The careful design of the machine combines very compact dimensions, which permit easy installation in false ceilings, with an excellent accessibility for maintaining all the internal components. Characteristics VERSIONS Standard horizontal configuration 5 sizes complete with temperature controller and ready for installation. PANELS: Self-supporting sandwich panel 0.78 inch thick in galvanised steel for internal and external surfaces with injected polyurethane insulation (density 2.5 lb/ft3). HEAT RECOVERY: Cross flow plate heat exchanger in aluminium with outputs over 50% in winter conditions. FILTERS: Class G3, 80% gravimetric efficiency, according to EN 779, thickness 1.89 inch located before the heat recovery both in the supply and return air flow. CENTRIFUGAL FANS: Double inlet forward curved blades with direct drive motor. Single phase 220V-60Hz single speed motor. The air flow is controlled, within +/- 15% of the nominal, through an electronic speed controller supplied as standard. REFRIGERANT CIRCUIT: Heat pump complete with high efficiency low noise scroll compressors, 4 way refrigerant cycle reversing valve, evaporator coil, condenser coil, liquid receiver, liquid separator, double thermostatic expansion valve, liquid sight glass (only for models 150, 210, 330), filter drier, high/low pressure pressostats. ELECTRICAL PANEL: The unit is provided with an electrical panel complete with power and control section (included the control for the 3 way valve for the supplementary hot water coil and associated actuators), ensuring the control of all the refrigerant circuit functions. Included are: NTC return air temperature sensor, external air temperature sensor, dampers and actuators in the free-cooling version, pressure switch in the supply air filter. Supplied loose is a remote mounted control terminal for automatic control of the unit and an outlet to power and control a light to conform with the current regulation for smoking zones. CONDENSATE DRAIN TRAY: Condensate drain tray in aluminium. ACCESSIBILITY: From below for the heat recovery, the filters, the condensate drain tray and the fans. 7

8 Accessories MBC casing with 2 row hot water coil to install on the supply air. Includes the three way valve and on-off actuator. FCE free-cooling complete with controls to be added to the existing. Free-cooling operation only works in the summer mode, if the external air temperature is at least 10K lower than the internal air temperature and if the compressor safeties permit it. FGC circular flanges. Each accessory consists of a flange to be connected to each unit's rectangular connection. G4F filter efficiency G4 MBX casing with single stage electrical heater with shrouded finned elements, with double safety thermostat of manual and automatic reset type, to install on the supply air. SUF silencer splitter module, in appropriate casing. The accessory consists of two modules: one for the supply and one for the return. RS485 board RS485 URX_CF RS485 FCE FGC G4F MBC MBX SUF Filters class G3 EN779 in supply and return Integrated heat pump refrigerant circuit with scroll compressor Reduced height for false ceiling installations Unit fitted with temperature controller with unit mounted electrical panel Electronic speed controller supplied as standard, to calibration the fan speed 8

9 9

10 Dimensional data (in) A C Cod.: SURXUY.01 / 1306 B Aermec reserves the right to make all modifications deemed necessary for improving the product at any time with any modification of technical data. Aermec S.p.A. Via Roma, Bevilacqua (VR) - Italia Tel Telefax

11 NEW URHE CF High efficiency heat recovery unit with refrigerant circuit without an external unit. Air flow from 588 to 1942 cfm R410A TECHNOLOGY HIGH EFFICIENCY The units from the URHE_CF series represent the high efficiency solution to satisfy the temperature and humidity comfort and ventilation requirements in air conditioning systems that serve public spaces and the commercial sector, such as offices, bars, restaurants, etc. The URHE_CF units are particularly efficient machines in that they use a high efficiency cross flow plate heat exchanger of high capacity combined with a heat pump refrigerant circuit operating with refrigerant R410A. The use of a high capacity cross flow heat recovery unit permits a significant reduction in the operating time of the refrigerant circuit throughout the year, thereby reducing to the minimum the electrical energy consumption. The small unit dimensions allow an easy installation even in false ceilings, allowing excellent accessibility for the maintenance of all the internal components. The numerous accessories available on request, for example the high efficiency compact filters, the hot water coil or the silencers, complete the functions of the machine which is usually combined to an air conditioning system. Characteristics VERSIONS 4 sizes available in horizontal configuration for ground or ceiling void installation. Unit complete with temperature controller and ready for installation. STRUCTURE AND PANELS: Structure in aluminium profiles with glass fibre reinforced nylon corner pieces. Sandwich panel 1 in thick with galvanised steel for the internal surface, prepainted for the external surface with injected polyurethane insulation (density 2.62 lb/ft3). HEAT RECOVERY: Cross flow plate heat exchanger in aluminium optimised to ensure high outputs. PLEATED FILTERS: Class G4, 80% gravimetric efficiency according to EN 779, thickness 1.9 in located before the heat recovery both in the supply and return air flow. CENTRIFUGAL FANS: High pressure forward curved impeller directly coupled to the motor. The air flow is maintained constant by the use of an electronic controller.. REFRIGERANT CIRCUIT: Heat pump with refrigerant R410A, complete with high efficiency low noise rotary or scroll compressors (depending on size), 4 way refrigerant cycle reversing valve, evaporator coil, condenser coil, liquid receiver, thermostatic expansion valve, liquid sight glass, filter drier, high pressure pressostat, low pressure pressostat, safety valve, bypass valve (for the smaller sizes). ELECTRICAL PANEL: The unit is provided with an electrical panel complete with power and control section (including the control for the 3 way valve for the supplementary hot water coil and associated actuators), ensuring the control of all the refrigerant circuit functions. Included are: NTC return air temperature sensor, external air temperature sensor, dampers and actuators in the free-cooling version, pressure switch in the supply air filter. Supplied loose is a remote mounted control terminal for automatic control of the unit. ENVIRONMENTALLY FRIENDLY: Through the applied technology and the use of ozone friendly refrigerant R410A, the URCHE_CF series is environmentally friendly. R410A is a refrigerant with high thermodynamic efficiency and this allows, together with the use of scroll compressors, to reduce CO 2 emissions. 11

12 Accessories MBCH hot water coil module MBCX electric heater module FCT high efficiency compact filters F7 BIT base for floor mounting BIM base for floor mounting for additional modules TPE roof for external installation TPM roof for external installation of additional modules FCH free-cooling kit RS485 board RS485 MSS n 1 silencer splitter module TPMSS roof for silencer splitter module FGE circular flanges URHE_CF MBCH MBCH1 MBCH1 MBCH1 MBCH2 MBCX MBCX1 MBCX2 MBCX3 MBCX4 FCT FCT1 FCT1 FCT2 FCT3 BIT BIT1 BIT1 BIT2 BIT3 BIM BIM1 BIM1 BIM1 BIM1 TPE TPE1 TPE1 TPE2 TPE3 TPM TPM1 TPM1 TPM1 TPM2 FCH FCH1 FCH1 FCH2 FCH2 RS485 RS485 RS485 RS485 RS485 MSS MSS1 MSS1 MSS2 MSS2 TPMSS TPMSS1 TPMSS1 TPMSS1 TPMSS2 FGE FGE1 FGE1 FGE1 FGE1 Filters class G4 EN779 in supply and return High efficiency plate heat exchanger Remote panel (standard) Inverter for fans standard to maintain constant air flow High efficiency heat pump refrigerant circuit Unit fitted with temperature controller with unit mounted electrical panel 12

13 13

14 Dimensional data (in) A B C Cod.: SURHECFUY.02 / 1309 Aermec reserves the right to make all modifications deemed necessary for improving the product at any time with any modification of technical data. Aermec S.p.A. Via Roma, Bevilacqua (VR) - Italia Tel Telefax

15 AERMEC North America 1608 Bonhill Road Mississauga, Ontario L5T 1C7 Ph: Toll Free Canada: Toll Free USA: Fax:

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Water Chillers - The range CH and RPW series

Water Chillers - The range CH and RPW series Water Chillers - The range CH and RPW series PIOVAN S.p.A. Cooling Centre 1 (1) Piovan Chiller Range Piovan Spa 03.2004 Modification reserved Water chillers A dedicated Cooling Centre Integration with

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

Low and High Static Pressure Fan Coil Units. VH2N 03 to 27. Technical Brochure. TM VH2N-A.1GB Date : June 2006 Supersedes : None

Low and High Static Pressure Fan Coil Units. VH2N 03 to 27. Technical Brochure. TM VH2N-A.1GB Date : June 2006 Supersedes : None Low and High Static Pressure Fan Coil Units VH2N 03 to 27 Technical Brochure TM VH2N-A.1GB Date : June 2006 Supersedes : None Design Features Presentation The VH2N fan coil units has been specially designed

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

Packaged Air Conditioner - Water Cooled Vertical Type Model 25

Packaged Air Conditioner - Water Cooled Vertical Type Model 25 Refrigerant R407C CX Packaged Air Conditioner - Water Cooled Vertical Type Model 25 8.0kW CX 25 1 Product Code Model Power supply Product code CX 25 230V / 1 ~ / 50 Hz 7XU012153 CX 25 CX 25 2 CX 25 General

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

High Static Pressure Ductable Fan Coil Unit Models 07 to 27

High Static Pressure Ductable Fan Coil Unit Models 07 to 27 VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 5.3 to 26.9kW 4.1 to 22.6kW 800 to 4650 m 3 /h VH 1 General Characteristics Presentation The new ducted high static pressure fan coil units

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

Cool Design for Homes and Offices

Cool Design for Homes and Offices AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners

More information

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

Innovent LASER Packaged Fresh Air Conditioning Units

Innovent LASER Packaged Fresh Air Conditioning Units LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent

More information

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings

More information

TECHNICAL MANUAL HEAT RECOVERY UNITS URE SERIES

TECHNICAL MANUAL HEAT RECOVERY UNITS URE SERIES TECHNICAL MANUAL HEAT RECOVERY UNITS URE SERIES SUMMARY 1. GENERAL FEATURES 2 2. VERSIONS AND COMPONENTS 2 3. ORIENTATIONS 3 4. NOMINAL TECHNICAL DATA 4 5. AVAILABLE ACCESSORIES 5 6. FAN CHARACTERISTICS

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

Mirage over door heater. Features: Electric and LPHW versions. Compact and Versatile. Suitable for mounting up to 3.0m high from finished floor level.

Mirage over door heater. Features: Electric and LPHW versions. Compact and Versatile. Suitable for mounting up to 3.0m high from finished floor level. Features: Electric and LPHW versions. Compact and Versatile Suitable for mounting up to 3.0m high from finished floor level. Recessed or surface mounted. Energy saving controls option available. Available

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

Mechanical Rooftop Custom Capabilities

Mechanical Rooftop Custom Capabilities Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT 48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

marine/bespoke split applications

marine/bespoke split applications split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments

More information

Variable Water Flow System. Providing superior cooling comfort. 60 Hz

Variable Water Flow System. Providing superior cooling comfort. 60 Hz Variable Water Flow System Providing superior cooling comfort 60 Hz Innovative comfort solution Trane, the leading global provider of HVAC systems, solutions, and services, provides worry-free cooling

More information

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency

More information

- White Paper - Data Centre Cooling. Best Practice

- White Paper - Data Centre Cooling. Best Practice - White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH

More information

Zehnder Focus 200. Ventilation device

Zehnder Focus 200. Ventilation device Ventilation device Use The Zehnder Focus (F) 200 comfort ventilation unit was specially developed for use in demanding residential and commercial buildings. It combines maximum comfort, simple operation

More information

Under sill units. Type FSL-B-ZAS

Under sill units. Type FSL-B-ZAS .1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

NSN 4120-01-21 4-3692

NSN 4120-01-21 4-3692 *TM 9-4120-388-14 TECHNICAL MANUAL Operator s, Unit, Direct Support, And General Support Maintenance Manual AIR CONDITIONER, VERTICAL, COMPACT, 18,000 BTU/HR 208 VOLT, 3 PHASE, 50/60 HERTZ NSN 4120-01-21

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

Bring the fresh in. Dedicated Outside Air Systems

Bring the fresh in. Dedicated Outside Air Systems Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health

More information

HEATER, AIR CONDITIONING AND VENTILATION

HEATER, AIR CONDITIONING AND VENTILATION 55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT

More information

AIR COOLED CONDENSERS WITH AXIAL FANS ACH / ACV (MONO COIL)

AIR COOLED CONDENSERS WITH AXIAL FANS ACH / ACV (MONO COIL) AIR COOLED CONDENSERS WITH AXIAL FANS ACH / ACV (MONO COIL) 5-1,420 kw REFRIGERANTS: available for all refrigerants incl. NH 3 and CO 2 vertical or horizontal tubes: Copper, Stainless Steel, Alu reliable

More information

CE8000 Energy Recovery Ventilator

CE8000 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 7000-8500 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel 18-gauge

More information

KONRAD. Hybrid Fancoil Series

KONRAD. Hybrid Fancoil Series KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks

More information

42DW. Horizontal Ducted Fan Coil Units. Nominal cooling capacity kw Nominal heating capacity kw. Features

42DW. Horizontal Ducted Fan Coil Units. Nominal cooling capacity kw Nominal heating capacity kw. Features Horizontal Ducted Fan Coil Units 42DW Nominal cooling capacity 5.5-12.7 kw Nominal heating capacity 7.3-17.9 kw The Carrier 42DW fan coil units offer reliable, economical cooling and heating for light

More information

Direct Fresh Air Free Cooling of Data Centres

Direct Fresh Air Free Cooling of Data Centres White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The

More information

CADB and CADT-D / DI / DC Series

CADB and CADT-D / DI / DC Series HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised

More information

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined

More information

Refrigeration Air Dryers. Catalogue

Refrigeration Air Dryers. Catalogue Refrigeration Air Dryers Catalogue GB Using a dryer is worth it Humidity is a component of atmospheric air, which can be found in our compressed air distribution systems and the machines that use the compressed

More information

Refrigerant R410A. Mini SysAqua DCI. 5.5 to 16.0kW. Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI

Refrigerant R410A. Mini SysAqua DCI. 5.5 to 16.0kW. Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI Refrigerant R4A Mini SysAqua DCI Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI 5.5 to 16.0kW Mini SysAqua DCI 1 Strength Points By introducing the variable speed in our packaged heat pump

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 Explanation of the refrigeration cycle. Compressors. Benefits and operating characteristics. -Reciprocating

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

www.inspection-for-industry.com

www.inspection-for-industry.com Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.

More information

Air handling unit. REC Temovex 250S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 250S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 25S-EC-RS Experts on indoor climate in low-energy houses RT 25S-EC-RS REC Temovex 25S-EC-RS Made in Sweden ECO2 control system for low-energy and passive houses Comprises: - Air flow boost

More information

type UTA Technical information manual

type UTA Technical information manual type UTA Technical information manual 2 > UTA ECHOS Ductable direct expansion fan coil unit 3 GENERALlTY Units for applications of residential and commercial type, characterised by reduced dimensions and

More information

BALTIC ROOFTOP PACKAGED UNIT. 20-85 kw AIR COOLED COOLING ONLY/HEAT PUMP/ GAS/ DUAL FUEL

BALTIC ROOFTOP PACKAGED UNIT. 20-85 kw AIR COOLED COOLING ONLY/HEAT PUMP/ GAS/ DUAL FUEL BALTIC ROOFTOP PACKAGED UNIT AIR COOLED COOLING ONLY/HEAT PUMP/ GAS/ DUAL FUEL 20-85 kw BALTIC, innovation in sustainable technologies Guaranteed sustainable performance with edrive With a rooftop, the

More information

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions. LH and GH/GL Series UNIT COOLERS Technical Bulletin: LHGH_001_07101 Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/ maximum height, the LH Series

More information

Lesson 36 Selection Of Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section

More information

We have been working in an ideal climate for thirty years.

We have been working in an ideal climate for thirty years. Underfloor cooling We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and cooling. RDZ was the

More information

CE6500 Energy Recovery Ventilator

CE6500 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge

More information

ROTARY SCREW COMPRESSOR. RMD 30-37 - 45-55 kw

ROTARY SCREW COMPRESSOR. RMD 30-37 - 45-55 kw ROTARY SCREW COMPRESSOR RMD - - - 55 kw EN The RMD Coaxial Rotary Compressor high reliability high performance low maintenance is the result of decades of experience in manufacturing design and construction

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS. DESCRIPTION FEATURES

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS.   DESCRIPTION FEATURES TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable

More information

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating Technical Development Program Technical Development Programs (TDP) are modules of technical training on HVAC theory, system

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

squrboxbox heat recovery squrboxbox I technical information

squrboxbox heat recovery squrboxbox I technical information heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution

More information

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant

More information

Kälte Klima. Condenserless chillers for indoor installation from 45 kw to 360 kw. Scroll compressors SCLY DE 48

Kälte Klima. Condenserless chillers for indoor installation from 45 kw to 360 kw. Scroll compressors SCLY DE 48 Condenserless chillers for indoor installation from 45 kw to 360 kw Scroll compressors Series: SCLY Leaflet: DE 48 Issue: 03/12 Supersedes: 04/11 Index Identification code Index... pag. 2 Identification

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES

More information

ASTACEA4 Inspect complex/central air conditioning systems

ASTACEA4 Inspect complex/central air conditioning systems Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

01 GB. Refrigeration Dryer. High quality compressed air. F-Series. Energy efficient compressed air treatment. 50Hz & 60Hz

01 GB. Refrigeration Dryer. High quality compressed air. F-Series. Energy efficient compressed air treatment. 50Hz & 60Hz 01 GB Refrigeration Dryer High quality compressed air Energy efficient compressed air treatment F-Series 50Hz & 60Hz Energy efficient refrigeration dryers First-class air treatment efficiency For CompAir,

More information

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled

More information

Flexit S3 R. Air Handling Unit - rotor technology - flexible installation FOR FLATS AND SMALL DETACHED HOUSES

Flexit S3 R. Air Handling Unit - rotor technology - flexible installation FOR FLATS AND SMALL DETACHED HOUSES Flexit S3 R Air Handling Unit - rotor technology - flexible installation FOR FLATS AND SMALL DETACHED HOUSES F O R A H E A LT H Y I N D O O R E N V I R O N M E N T Flexit S3 R Air Handling Unit with Rotor

More information

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS Made in Sweden ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for

More information

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50

More information

PLUG and PLAY VRV Connection

PLUG and PLAY VRV Connection PLUG and PLAY VRV Connection All seasons Perfect c mfort Heating Air Conditioning Applied Systems Refrigeration Pricelist 2010 Air Handling Units for > VRV Indoor units and Air Handling Units on single

More information

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System Auxiliary HVAC RAM ProMaster Standard Tie-in Extreme Climate System Auxiliary HVAC High performance aftermarket heating and cooling systems engineered for vehicle specific platforms that minimize install

More information

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER May 2012 VERSION 1.3 Please read instructions carefully before installation. This unit is a complete fresh air make-up package with an integrated

More information

COMFORT LINE. Ductable comfort units. New ductable comfort unit "An innovative solution promoting wellbeing" comfort line...

COMFORT LINE. Ductable comfort units. New ductable comfort unit An innovative solution promoting wellbeing comfort line... New ductable comfort unit "An innovative solution promoting wellbeing" comfort line... n Because it is essential to offer solutions which meet our customers' expectations. n Because we need to develop

More information

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety

More information

Refrigerated Air Dryers. Catalogue

Refrigerated Air Dryers. Catalogue Refrigerated Air Dryers Catalogue GB Why use a refrigerated dryer? Humidity is a component of atmospheric air, which can be found in the compressed air distribution systems and the machines that use the

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

1932 Lexington Houston, Texas 77098-4220 (713) 524-4877. Recommendations for installation of cooling systems

1932 Lexington Houston, Texas 77098-4220 (713) 524-4877. Recommendations for installation of cooling systems 1932 Lexington Houston, Texas 77098-4220 (713) 524-4877 The purpose for this information is to provide a better understanding of the HVAC equipment, components, designs, and installations, of HVAC system

More information

Condensing unit type EPSILON-ECHOS LE Technical information manual

Condensing unit type EPSILON-ECHOS LE Technical information manual Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

50 AZs. Packaged Rooftop/Cooling Units. Nominal cooling capacity kw. Features

50 AZs. Packaged Rooftop/Cooling Units. Nominal cooling capacity kw. Features Packaged Rooftop/Cooling Units 0036 Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 50 AZs Nominal cooling capacity

More information

Adsorption air dryers ADS 1 215

Adsorption air dryers ADS 1 215 Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that

More information

OIL SEPARATORS. 112

OIL SEPARATORS. 112 OIL SEPARATORS 111 OIL SEPARATORS APPLICATIONS The oil separators, shown in this chapter, are classified Pressure vessels in the sense of the Pressure Equipment Directive 97/23/EC, Article 1, Section 2.1.1

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

Energy Efficiency HOSPITALITY. www.energia.ie

Energy Efficiency HOSPITALITY. www.energia.ie Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,

More information

PIZZA CHEF COUNTERS PZ2037A EURONORM PZ REFRIGERATED COUNTER: TECHNICAL FEATURES

PIZZA CHEF COUNTERS PZ2037A EURONORM PZ REFRIGERATED COUNTER: TECHNICAL FEATURES PIZZA CHEF COUNTERS PIZZA CHEF COUNTERS PZ2037A EURONORM PZ REFRIGERATED COUNTER: TECHNICAL FEATURES - All-in-one structure with an insulating thickness varying from 60 mm to 40 mm; the insulation is ensured

More information

01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09

01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09 0000-00 01-3 6810-20 1. FFH SPECIFICATION 01-4 0000-00 2. SYSTEM LAYOUT AND COMPONENTS 0000-00 01-5 01-6 0000-00 3. FFH GENERAL INFORMATION The system is to increase the coolant temperature quickly by

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information