EMC TEST REPORT. Report No.: CE10-LIE040103E
|
|
|
- Phillip Cook
- 9 years ago
- Views:
Transcription
1 EMC TEST REPORT Report No.: CE10-LIE040103E Product: LED OUTDOOR LIGHTING Model No.: Wall Washer, Projector, Underground light, Street Light, Underwater Light, Strip Light Applicant: Shenzhen Saiju Electronic Co., Ltd. Address: 2nd. Xianshun Industrial Park, Gushu, Xixiang, Bao an, Shenzhen, Guangdong, China. Issued by: Shenzhen EBO Testing Center Lab Location: Yihua Building, Shennan Road, Futian District, Shenzhen, , P. R. China Tel: Fax: This test report consists of 36 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by EBO. The test results in the report only apply to the tested sample. The test report shall be invalid without all the signatures of testing engineers, reviewer and approver. Any objections must be raised to EBO within 15 days since the date when the report is received. It will not be taken into consideration beyond this limit. Page 1 of 36
2 Table of Contents 1 Test Report Certification General Information Description of EUT Objective Test Standards and Results List of Equipments Used Emission Test EUT Setup and Operating Conditions Mains Terminal Disturbance Voltage Measurement Limits of Mains Terminal Disturbance Voltage Test Procedure Test Setup Test Result Radiated Electromagnetic Disturbance Measurement Limits of Radiated Electromagnetic Disturbance Test Procedure Test Setup Test Results Harmonic Current Measurement Limits of Harmonic Current Test Procedure Test Setup Test Result Voltage Fluctuation and Flick Measurement Limits of Voltage Fluctuation and Flick Test Procedure...19 Page 2 of 36
3 3.5.3 Test Result Immunity Test EUT Setup and Operating Conditions Performance Criteria Electrostatic Discharge Immunity Test Test Specification Test Procedure Test Setup Test Result Radiated, Radio Frequency Electromagnetic Field Immunity Test Test Specification Test Procedure Test Setup Test Result Electrical Fast Transient/Burst Immunity Test Test Specification Test Procedure Test Setup Test Result Surge Immunity Test Test Specification Test Procedure Test Setup Test Result Immunity to Conducted Disturbances Induced by RF Fields Test Specification Test Procedure...29 Page 3 of 36
4 4.7.3 Test Setup Test Result Voltage Dips and Short Interruptions Immunity Test Test Specification Test Procedure Test Setup Test Result Power Frequency Magnetic Field Immunity Test Test Specification Test Procedure Test Setup Test Result...33 Appendix I:Photographs of the EUT...34 Page 4 of 36
5 1 Test Report Certification Product: LED OUTDOOR LIGHTING Model No.: Wall Washer, Projector, Underground light, Street Light, Underwater Light, Strip Light Applicant: Shenzhen Saiju Electronic Co., Ltd. Applicant Address: 2nd. Xianshun Industrial Park, Gushu, Xixiang, Bao an, Shenzhen, Guangdong, China. Manufacturer: Shenzhen Saiju Electronic Co., Ltd. Manufacturer 2nd. Xianshun Industrial Park, Gushu, Xixiang, Bao an, Shenzhen, Address: Guangdong, China. Test Standards: EN 55015:2006+ A1:2007 EN 61547:1995+ A1:2000+A2:2005 EN :2006 EN :1995+A1:2001+A2:2005 Test Result: PASS We, Shenzhen EBO Testing Center, hereby certify that the submitted samples of the above item, as detailed in chapter 2.1 of this report, has been tested in our facility. The test record, data evaluation and test configuration represented herein are true and accurate accounts of measurements of the sample s EMC characteristics under the conditions herein specified. Tested by:, Date: April 01, 2010 Smart Li Approved by:, Date: April 01, 2010 Kevin Yu Page 5 of 36
6 2 General Information 2.1 Description of EUT Product: LED OUTDOOR LIGHTING Model No.: Wall Washer, Projector, Underground light, Street Light, Underwater Light, Strip Light Brand Name: Serial No.: Electrical Rating: AC85~265V,50~60HZ I/O Ports: / Accessories: / NOTE: 1. Please refer to Appendix I for the photographs of the EUT. For more detailed features description about the EUT, please refer to User s Manual. 2.2 Objective Perform ElectroMagnetic Interference (EMI) and ElectroMagnetic Susceptibility (EMS) tests for CE Marking. Page 6 of 36
7 2.3 Test Standards and Results The EUT has been tested according to the following specifications: EMISSION Standard Test Type Result Mains terminal disturbance voltage PASS EN 55015:2006+ A1:2007 Radiated Electromagnetic Disturbance Measurement PASS EN : 2006 Harmonic current emissions PASS EN :1995+A1:2001+ A2:2005 Voltage fluctuation & flicker PASS IMMUNITY (EN61547:1995+A1:2000+A2:2005) Basic Standard Test Type Result EN Electrostatic discharge immunity PASS EN Radiated, radio frequency electromagnetic field immunity PASS EN Electrical fast transient/burst immunity PASS EN Surge immunity PASS EN Immunity to conducted disturbances induced by RF fields PASS EN Power frequency magnetic field immunity PASS EN Voltage dips and short interruptions immunity PASS NOTE: The latest versions of basic standards are applied. Page 7 of 36
8 2.4 List of Equipments Used Description Manufacturer Model No. Serial No. Test Receiver Schwarzbeck FCKL1528 A LISN Schwarzbeck NSLK8127 A Loop Antenna Schwarzbeck HXYZ8170 A Antenna Amplifier Research AR AT1080 A Power Frequency Test System HAEFELY PHF 555 A ESD Test System HAEFELY FESD16000 A EFT Test System HAEFELY PEFT JUNIOR A Surge Test System HAEFELY PSurge8000 A Signal Generator ROHDE&SCHWARZ SML02 A Power Amplifier Amplifier Research AR 150W1000 A Power Amplifier Amplifier Research AR 75A250M A Field Monitor Amplifier Research AR FM Magnetic Field Tester HAEFELY MAG A Shield Room Nanbo Tech Site 3 A Shield Room Nanbo Tech Site 1 A NOTE: Equipments listed above have been calibrated and are in the period of validation. Page 8 of 36
9 3 Emission Test 3.1 EUT Setup and Operating Conditions The lamp was powered by 230V 50Hz AC Mains. 3.2 Mains Terminal Disturbance Voltage Measurement Limits of Mains Terminal Disturbance Voltage Frequency range Quasi-peak Limits (dbμv) Average 9kHz to 50kHz kHz to 150kHz 90 to kHz to 0.5MHz 66 to to MHz to 2.51MHz MHz to 3.0MHz MHz to 5.0MHz MHz to 30MHz NOTE: 1. The lower limit shall apply at the transition frequencies. 2. The limit decreases linearly with the logarithm of the frequency in the range 50 khz to 150 khz and 150 khz to 0.5MHz Test Procedure a. The EUT was placed 0.4 meters from the conducting wall of shielded room with EUT being connected to the power mains through a line impedance stabilization network (LISN). The LISN provide 50Ω/50μH of coupling impedance for the measuring instrument. b. Both lines of the power mains connected to the EUT were checked for maximum conducted interference. c. The frequency range from 9 khz to 30MHz was searched. Emission levels over 10dB under the prescribed limits are not reported. Page 9 of 36
10 3.2.3 Test Setup For the actual test configuration, please refer to the related item - Photographs of the Test Configuration Test Result No. Freq. (MHz) Limit Value (dbμv) Emission Level (dbμv) QP AV QP AV NOTE: 1. QP and AV are abbreviations of the quasi-peak and average individually. 2. If the emission levels measured with QP detector are lower than AV limits, there is unnecessary to measure with AV detector. 3. The emission levels recorded above are the larger ones of both L phase and N phase. Page 10 of 36
11 1. Mains terminal disturbance voltage,l phase 2. Mains terminal disturbance voltage,n phase Page 11 of 36
12 3.3 Radiated Electromagnetic Disturbance Measurement Limits of Radiated Electromagnetic Disturbance Notes: Frequency range (MHz) QP Limits(dBμΑ), for loop antenna with a diameter of 2m to to to to to to to (1) The lower limit shall apply at the transition frequency. (2) The limit decreases linearly with the logarithm of the frequency in the range 70 khz to 150kHz. (3) The limit increases linearly with the logarithm of the frequency in the range 150 khz to 2.2MHz Test Procedure a. The magnetic component of radiated electromagnetic disturbance is measured by means of a loop antenna. b. The induced current in the loop antenna is measured by means of a current probe (1V/A) and the CISPR measuring receiver. By means of a coaxial switch, the three field directions are measured in sequence. c. The EUT was placed in the center of the loop antenna, on an insulated table. Page 12 of 36
13 3.3.3 Test Setup For the actual test configuration, please refer to the related item-photographs of the Test Configuration Test Results No. Antenna QP Limits Emission Level Frequency (MHz) Direction (dbμa) (dbμα) 1 X/Y/Z <30 2 X/Y/Z <30 3 X/Y/Z <20 4 X/Y/Z <20 5 X/Y/Z <10 Page 13 of 36
14 1.Radiated electromagnetic disturbance, loop antenna direction: X 2.Radiated electromagnetic disturbance, loop antenna direction: Y Page 14 of 36
15 3.Radiated electromagnetic disturbance, loop antenna direction: Z Page 15 of 36
16 3.4 Harmonic Current Measurement Limits of Harmonic Current Harmonic order n Limits for Class D Equipment Maximum permissible harmonic current per watt ma/w Maximum permissible harmonic current n 39 (odd harmonic only) 3.85/n /n NOTE: 1. According to section 5 of EN : 2000, the EUT is Class D equipment. 2. The above limits are for all applications having an active input power>75w. No limits apply for equipment with an active input power up to and including 75W Test Procedure a. The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated to produce the maximum harmonic components under normal operating conditions for each successive harmonic component in turn. b. The correspondent test program of test instrument to measure the current harmonics emanated from EUT is chosen. The measure time shall be not less than the necessary for the EUT to be exercised. A Page 16 of 36
17 3.4.3 Test Setup For the actual test configuration, please refer to Appendix II : Photographs of the Test Configuration Test Result Test Specification Test Frequency: 50Hz Test Voltage: 230Vac Waveform: Sine Test Time: 2.5min Classification: Class D Harmonics Harmonics Harmonics Harmonics Limit (A) Order Current (A) Order Current (A) Limit (A) Page 17 of 36
18 Page 18 of 36
19 3.5 Voltage Fluctuation and Flick Measurement Limits of Voltage Fluctuation and Flick Test Item Limit Note P st 1.0 P st means Short-term flicker indicator P lt 0.65 P lt means long-term flicker indicator T dt 0.2 T dt means maximum time that d t exceeds 3% d max (%) 4% d max means maximum relative voltage change. d c (%) 3% d c means relative steady-state voltage change Test Procedure a. The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated to produce the most unfavorable sequence of voltage changes under normal conditions b. During the flick measurement, the measure time shall include that part of whole operation changes. The observation period for short-term flicker indicator is 10 minutes and the observation period for long-term flicker indicator is 2 hours Test Result Test Specification Test Frequency: 50Hz Test Voltage: 230Vac Waveform: Sine Test Time: 10 minutes(p st ); 2 hours (P lt ) Test Result Test Parameter Measurement Value Limit Remarks P st Pass P lt Pass T dt(s) Pass d max (%) 0.00% 4% Pass d c (%) 0.00% 3% Pass Page 19 of 36
20 4 Immunity Test 4.1 EUT Setup and Operating Conditions Same as Performance Criteria Criterion A During the test no change of the luminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended. During the test the luminous intensity may change to any value. After the test the luminous Criterion B intensity shall be restored to its initial value within 1 minute. Regulating controls need not function during the test, but after the test the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given. During and after the test any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 minutes, all functions shall return to normal if Criterion C necessary be by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test the lighting equipment is switch off. After half an hour it is switched on again. The lighting equipment shall start and operate as intended. 4.3 Electrostatic Discharge Immunity Test Test Specification Basic Standard: EN Discharge Impedance 330Ω / 150 pf Discharge Voltage: Air Discharge 8 kv Contact Discharge 4 kv Polarity: Positive / Negative Number of Discharge: Minimum 20 times at each test point Discharge Mode: Single discharge Discharge Period: 1-second minimum Page 20 of 36
21 4.3.2 Test Procedure The discharges shall be applied in two ways: a. Contact discharges to the conductive surfaces and coupling planes: The EUT shall be exposed to at least 200 discharges, 100 each at negative and positive polarity, at a minimum of four test points. One of the test points shall be subjected to at least 50 indirect discharges to the center of the front edge of the horizontal coupling plane. The remaining three contact test points shall each receive at least 50 direct contact discharges. If no direct contact test points are available, at least 200 indirect discharges shall be applied in the indirect mode. Test shall be performed at a maximum repetition rate of one discharge per second. b. Air discharges at slots and apertures and insulating surfaces: On those parts of the EUT where it is not possible to perform contact discharge testing, the equipment should be investigated to identify user accessible points where breakdown may occur. Such points are tested using the air discharge method. This investigation should be restricted to those area normally handled selected test point for each such area. The basic test procedure was in accordance with EN : a. Electrostatic discharges were applied only to those points and surfaces of the EUT that are accessible to users during normal operation. b. The test was performed with at least ten single discharges on the pre-selected points in the most sensitive polarity. c. The time interval between two successive single discharges was at least 1 second. d. The ESD generator was held perpendicularly to the surface to which the discharge was applied and the return cable was at least 0.2 meters from the EUT. e. Contact discharges were applied to the non-insulating coating, with the pointed tip of the generator penetrating the coating and contacting the conducting substrate. f. Air discharges were applied with the round discharge tip of the discharge electrode approaching the EUT as fast as possible (without causing mechanical damage) to touch the EUT. After each discharge, the ESD generator was removed from the EUT and re-triggered for a new single discharge. The test was repeated until all discharges were completed. g. At least ten single discharges (in the most sensitive polarity) were applied to the Horizontal Coupling Plane at points on each side of the EUT. The ESD generator was positioned Page 21 of 36
22 vertically at a distance of 0.1 meters from the EUT with the discharge electrode touching the HCP. h. At least ten single discharges (in the most sensitive polarity) were applied to the center of one vertical edge of the Vertical Coupling Plane in sufficiently different positions that the four faces of the EUT were completely illuminated. The VCP (dimensions 0.5m 0.5m) was placed vertically to and 0.1 meters from the EUT Test Setup For the actual test configuration, please refer to Appendix II : Photographs of the Test Configuration Test Result Test Points Discharge Discharge Comply with Observation Level (kv) Mode Criterion HCP ±4 Contact Note(1) A VCP ±4 Contact Note(1) A Cover ±8 Air Note(1) A Metal ±8 Air Note(1) A NOTE: (1). The EUT continued to operate as intended. No degradation of performance was observed.. Page 22 of 36
23 4.4 Radiated, Radio Frequency Electromagnetic Field Immunity Test Test Specification Basic Standard: EN Frequency Range: 80 MHz 1000MHz Field Strength: 3V/m Modulation: 1kHz sine wave, 80%, AM modulation Frequency Step: 1% of fundamental Polarity of Antenna Horizontal and Vertical Test Distance: 3m Antenna Height: 1.5m Dwell Time: 3 seconds Test Procedure The test procedure was in accordance with EN a. The testing was performed in a fully anechoic chamber. The transmit antenna was located at a distance of 3 meters from the EUT. b. The frequency range is swept from 80 MHz to 1000MHz with the signal 80% amplitude modulated with a 1 khz sine wave. The rate of sweep did not exceed decade/s. Where the frequency range is swept incrementally, the step size was 1% of fundamental. c. The dwell time at each frequency shall be not less than the time necessary for the EUT to be able to respond. d. The field strength level was 3V/m. e. The test was performed with the EUT exposed to both vertically and horizontally polarized fields on each of the four sides. Page 23 of 36
24 .4.3 Test Setup For the actual test configuration, please refer to Appendix II : Photographs of the Test Configuration Test Result Frequency Polarity Azimuth Field Strength (V/m) Observation Comply with Criterion MHz V&H 0 3 Note(1) A MHz V&H 90 3 Note(1) A MHz V&H Note(1) A MHz V&H Note(1) A NOTE: (1). The EUT continued to operate as intended. No degradation of performance was observed. Page 24 of 36
25 4.5 Electrical Fast Transient/Burst Immunity Test Test Specification Basic Standard: EN Test Voltage: a.c. power port 1 kv Polarity: Positive/Negative Impulse Frequency: 5kHz Impulse wave shape: 5/50ns Burst Duration: 15ms Burst Period: 300ms Test Duration: Not less than 1 min Test Procedure a. The EUT was tested with 1000 volt discharges to the AC power input leads. b. Both positive and negative polarity discharges were applied. c. The length of the hot wire from the coaxial output of the EFT generator to the terminals on the EUT should not exceed 1 meter. d. The duration time of each test sequential was 1 minute. e. The transient/burst waveform was in accordance with EN , 5/50ns. Page 25 of 36
26 4.5.3 Test Setup For the actual test configuration, please refer to Appendix II : Photographs of the Test Configuration. Page 26 of 36
27 4.5.4 Test Result Test Point Polarity Test Level (kv) Observation Comply with Criterion L +/- 1 Note (1) A N +/- 1 Note (1) A L-N +/- 1 Note (1) A NOTE: (1). The EUT continued to operate as intended. No degradation of performance was observed. 4.6 Surge Immunity Test Test Specification Basic Standard: EN Waveform: Voltage 1.2/50 μs; Current 8/20 μs Test Voltage: Power port, line to line 1kV Polarity: Positive/Negative Phase Angle: 0, 90, 180, 270 Repetition Rate: 60sec Times: 5 time/each condition Test Procedure a. The EUT and the auxiliary equipment were placed on a table of 0.8m heights above a metal ground reference plane. The size of ground plane is greater than 1m 1m and project beyond the EUT by at least 0.1m on all sides. The ground plane is connected to the protective earth. The length of power cord between the coupling device and the EUT was less than 2 meters (provided by the manufacturer). b. The EUT was connected to the power mains through a coupling device that directly couples the surge interference signal. The surge noise was applied synchronized to the voltage phase at the zero crossing and the peak value of the AC voltage wave (positive and negative). c. The surges were applied line to line and line(s) to earth. When testing line to earth the test voltage was applied successively between each of the lines and earth. Steps up to the test level specified increased the test voltage. All lower levels including the selected test level were tested. The polarity of each surge level included positive and negative test pulses. Page 27 of 36
28 4.6.3 Test Setup For the actual test configuration, please refer to Appendix II : Photographs of the Test Configuration Test Result Coupling Line Polarity Voltage (kv) Observation Comply with Criterion a.c. power, L-N +/- 1 Note (1) A NOTE: (1). The EUT continued to operate as intended. No degradation of performance was observed. Page 28 of 36
29 4.7 Immunity to Conducted Disturbances Induced by RF Fields Test Specification Basic Standard: EN Frequency Range: 0.15 MHz 80 MHz Field Strength: 3V Modulation: 1 khz Sine Wave, 80%, AM Modulation Frequency Step: 1% of fundamental Coupled Cable: a.c. power line Coupling Device: CDN-M Test Procedure a. The EUT shall be tested within its intended operating and climatic conditions. b. The test shall be performed with the test generator connected to each of the coupling and decoupling devices in turn, while the other non-excited RF input ports of the coupling devices are terminated by a 50-ohm load resistor. c. The frequency range is swept from 150 khz to 80 MHz, using the signal level established during the setting process and with a disturbance signal of 80% amplitude. The signal is modulated with a 1 khz sine wave, pausing to adjust the RF signal level or the switch coupling devices as necessary. The sweep rate shall not exceed decades/s. The step size shall not exceed 1% of the start and thereafter 1% of the preceding frequency value where the frequency is swept incrementally. d. The dwell time at each frequency shall not be less than the time necessary for the EUT to be exercised, and able to respond. Sensitive frequencies such as clock frequencies and harmonics or frequencies of dominant interest, shall be analyzed separately. e. Attempts should be made to fully exercise the EUT during test, and to fully interrogate all exercise modes selected for susceptibility. Page 29 of 36
30 4.7.3 Test Setup For the actual test configuration, please refer to Appendix II : Photographs of the Test Configuration Test Result Test Point Frequency Field Strength Observation Comply with criterion (Vrms) a.c. power line MHz 3 Note(1) A NOTE: (1). The EUT continued to operate as intended. No degradation of performance was observed. Page 30 of 36
31 4.8 Voltage Dips and Short Interruptions Immunity Test Test Specification Basic Standard: EN Voltage Dips: 30% reduction, 10 periods 100% reduction, 0.5 periods Voltage Phase Angle: Test Procedure a. The power cord was used as supplied by the manufacturer. The EUT was connected to the line output of the Voltage Dips and Interruption Generator. b. The EUT was tested for (I) 30% voltage dip of supplied voltage with duration of 200ms, (II) 100% voltage dip of supplied voltage and duration 10ms. Both of the dip tests were carried out for a sequence of three voltage dips with intervals of 10 seconds. c. Voltage reductions occur at 0 degree crossover point of the voltage waveform. The performance of the EUT was checked after the voltage dip or interruption Test Setup For the actual test configuration, please refer to Appendix II : Photographs of the Test Configuration. Page 31 of 36
32 4.8.4 Test Result Test Mode Voltage dips Note: Voltage Duration Times Interval Comply with Observation Reduction (ms) (Sec) Criterion 30% Note (1) B 100% Note (1) B (1).The luminous intensity decreased during the test. After the test the luminous intensity self restored within 1 minute, no other degradation of performance or loss of function was observed. 4.9 Power Frequency Magnetic Field Immunity Test Test Specification Basic Standard: EN Frequency Range: 50Hz Field Strength: 3A/m Observation Time: 2 minute Inductance Coil: Rectangular type, 1m 1m Test Procedure a. The equipment is configured and connected to satisfy its functional requirements. It shall be placed on the GRP with the interposition of a 0.1m thick insulating support. b. The equipment cabinets shall be connected to the safety earth directly on the GRP via the earth terminal of the EUT. c. The power supply, input and output circuits shall be connected to the sources of power supply, control and signal. d. The cables supplied or recommended by the equipment manufacturer shall be used. 1 meter of all cables used shall be exposed to the magnetic field. Page 32 of 36
33 4.9.3 Test Setup For the actual test configuration, please refer to Appendix II : Photographs of the Test Configuration Test Result Direction Field Strength(A/m) Observation Comply with Criterion X 3 Note(1) A Y 3 Note(1) A Z 3 Note(1) A NOTE: The EUT continued to operate as intended. No degradation of performance was observed Page 33 of 36
34 Appendix I:Photographs of the EUT Page 34 of 36
35 Page 35 of 36
36 (EBO authenticate the photo on original report only) *** End of Report *** Page 36 of 36
Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W
14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02
SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT
Shenzhen BST Technology Co., Ltd. SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Prepared For : Product Name: Model : Prepared By : SHENZHEN GEMBIRD ELECTRONICS LTD 5th Floor, Building B, Shifeng Industry
TEST REPORT EN 55014-2 (1997) +A1 (2001)
Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....
EMC TEST REPORT For. Webcam. Model Number: CAM67U
EMC TEST REPORT For Webcam Model Number: CAM67U Prepared for : Gembird Europe B.V. Wittevrouwen 56, 1358CD Almere, The Netherlands. Phone: +31-36-5211588 Prepared By : Shenzhen Meihua Electronic Technology
Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820
Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)
EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20
EMC TEST REPORT For Shenzhen Homelux Security Equipment Co., Ltd Auto Dialer Model No.: HX-GD20 Prepared for : Shenzhen Homelux Security Equipment Co., Ltd Address : 4 th Floor, Building 5, Jiademaluan
Test Report #: 1981-3 Date: April 8, 2005
Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model
Electromagnetic Compatibility Test Report Test results of Floww equipment
Electromagnetic Compatibility Test Report Test results of Floww equipment Reference number Status test report Brand Model number : 10C00357RPT01.doc : Final : Floww : mobilefloww screenfloww pocketfloww
Declaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SND6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
Declaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SCP2371HP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.
EMC TEST REPORT Project No. LBE091881 Revision No. NONE Name of organization Samsung Electronics Co., Ltd. Applicant Address 416 Maetan 3-Dong,Yeongtong-Gu,Suwon-Si, Gyeonggi-Do, 443-742 Korea Date of
Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.
www.ecmg-global.com EMC TEST REPORT On Model Name: DL-P40 Computer Control System Model Number: Release 3.0 Hardware and Software Brand Name: Dorman Long Technology Ltd. Trade Mark: DLT Prepared for Dorman
TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio
TEST REPORT Rapporto di prova EMC N 060406 EUT: Organic Carbon Analyzer Analiuzzatore Carbonio Organico Model: TOCMETER Serial N : TM602 Client: TRE-ESSE s.r.l. Cliente Piazzale Europa 8 16036 Recco (GE),
MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2
MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 EN55024 (1998), EN61000-3-2 (2001), EN61000-3-3 (1995 W/A1: 98), EN55022 (1998) CLASS A, CISPR 22 (1997) CLASS A & FCC PART 15 SUBPART
Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter
Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Model: Solid State Energy Meter Prepared for: Analog Devices, Inc. 804 Woburn Street Wilmington, MA 01887 Date of
TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement
TEST REPORT Applicant Address Shenzhen Gembird Electronics Ltd. 5F, Building B, Shi-Feng Industrial Zone, Hua-Ning Rd., Xin-Wei Village, Da-Lang Street, Long-Hua, Bao-An Area, Shenzhen 518109, Guangdong
Declaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNP-6200RHP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
Declaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNO-6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5
EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA
CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.
EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD. CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 Phone: +86-755-83585700 3A, F1.6, Tianfa Building, Tian an Cyber Park, Fax: +86-755-83585701 Futian
EMC Test for Compliance with EU EMC Directive 2004/108/EU
EMC Test for Compliance with EU EMC Directive 2004/108/EU Partial Test 12-12-2012 Standards Description EN 55022:2011 Information technology equipment - Radio disturbance characteristics - Limits and methods
FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT
FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT For SAMBO HI TECH CO., LTD. 616-15, GANSUK4-DONG, NAMDONG-GU, INCHUN 405-810, KOREA Model: LSR700, SCI545HV1EF, SCI545HVEF This Report Concerns: Original
Declaration of Conformity.
Declaration of Conformity. Type of equipment Brand Name /Trade Mark Type designation /model Applicant Network Camera SAMSUNG SND-5083P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives
Current Probes. User Manual
Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall
Declaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SNP-5300P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.
EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory
NMI M 6-2 Electricity Meters. Part 2: Test Report Format
NMI M 6-2 Electricity Meters Part 2: Test Report Format Commonwealth of Australia 2010 First edition September 2010 National Measurement Institute Bradfield Road, Lindfield, NSW 2070 PO Box 264, Lindfield,
RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,
APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP
Measurement of RF Emissions from a Final Coat Electronics Corrosion Module
Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA
STRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
EMC TEST REPORT. Page: 1 of 38. Reference No.: WT08010091-S-E
Page: 1 of 38 EMC TEST REPORT Reference No. Applicant Address : WT08010091-S-E : Gembird Electronics Ltd. : Room 1709 A, News Building, #2 Shennan Zhong Lu, Shenzhen, China Equipment Under Test (EUT) :
15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010
ELECTROMAGNETIC COMPATIBILITY TEST Report reference N R-255 EMC 2010 Constructor. Address Reference person. C LUCE S.r.l. Via Marmolada 5/11 20060 Truccazzano (MI) Italy ---- Product....... Model......
Dual Chamber Temporary External Pacemaker
5392 Dual Chamber Temporary External Pacemaker Electromagnetic Compatibility Declaration Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list includes
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
30 In Compliance October 2014 www.incompliancemag.com
30 In Compliance October 2014 www.incompliancemag.com Medical Devices in a Wireless World BY IVAYLO TANKOV While wireless technology is now an integral component of a wide variety of manufactured products,
The EMI-Receiver according to CISPR 16-1-1
Author: Dipl. -Ing. Dieter Schwarzbeck Schwarzbeck Mess-Elektronik An der Klinge 29 D-69250 Schönau / Germany Tel.: +49 6228 1001 Fax.:+49 6228 1003 [email protected] www.schwarzbeck.de Requirements
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)
CERTIFICATE Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03 This is to certify that the following designated product Product Trade name Model Number : 1 Port Device Server : Moxa : NPort 5150(-T),
AN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x
TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x On January 1, 1996, exports into Europe began facing some tough transient immunity standards. The International Electrotechnical Commission (IEC), a worldwide
TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.
198 Kezhu Road, Scientech Park, Guangzhou Economic & Technological Development District, Guangzhou, China 510663 Telephone: +86 (0) 20 82155555 Fax: +86 (0) 20 82075059 Email: [email protected]
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.
588 West Jindu Road,Songjiang District,Shanghai,China Telephone: +86 (0) 21 6191 5666 Fax: +86 (0) 21 6191 5678 [email protected] Page: 1 of 23 1 Cover Page Application No.: Applicant: Manufacturer:
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE
CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE of Product Name Model Brand Memorex; Imation; TDK Life on Record Contains: 1. Declaration of Conformity 2. EN55022/CISPR 22, AS/NZS CISPR 22 EMI test
RX-AM4SF Receiver. Pin-out. Connections
RX-AM4SF Receiver The super-heterodyne receiver RX-AM4SF can provide a RSSI output indicating the amplitude of the received signal: this output can be used to create a field-strength meter capable to indicate
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS
Page 1 UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS By Henry Ott Consultants Livingston, NJ 07039 (973) 992-1793 www.hottconsultants.com [email protected] Page 2 THE BASIC
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Design and Certification of ASH Radio Systems for Japan
Design and Certification of ASH Radio Systems for Japan RFM s second-generation ASH radio hybrids are being used in a wide variety of applications in Japan, operating under the Japanese BIJAKU radio regulations.
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations.
Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations. D. A. Weston RE02Tx.rep 14-6-2004 NARTE Certified EMC
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology
Antennas for EMC Testing Zhong Chen ETS-Lindgren 1301 Arrow Point Drive Cedar Park, TX 78613 [email protected] Outline EMC Terms and Definitions Typical EMC Antennas Calibration of EMC Antennas
RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.
Receiver AC-RX2/CS RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. Pin-out 38.1 3 Component Side 1 2 3 7 11 13 14 15
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
AN1200.04. Application Note: FCC Regulations for ISM Band Devices: 902-928 MHz. FCC Regulations for ISM Band Devices: 902-928 MHz
AN1200.04 Application Note: FCC Regulations for ISM Band Devices: Copyright Semtech 2006 1 of 15 www.semtech.com 1 Table of Contents 1 Table of Contents...2 1.1 Index of Figures...2 1.2 Index of Tables...2
AMIS. Automated Metering and Information System. Integration of meters from other manufacturers
AMIS Automated Metering and Information System TD-3530/TACU30 Third-Party Device Gateway Integration of meters from other manufacturers Connection and integration of max. 3 meters from third party manufactureres
80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 6 A 80. Multi-function and mono-function timer range - Multi-function & multi-voltage 80. - ON delay, multi-voltage 7.5 mm wide Six time scales from 0.s to 24h 35 mm rail (EN
NMI R 118 Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIML R 118:1995(E), NEQ)
Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIM R 118:1995(E), NEQ) The English version of international standard OIM R 118:1995 Testing Procedures
Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants www.hottconsultants.com
Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants www.hottconsultants.com Workbench EMC measurements are simple, inexpensive precompliance tests that a product designer can perform early
A wave lab inside a coaxial cable
INSTITUTE OF PHYSICS PUBLISHING Eur. J. Phys. 25 (2004) 581 591 EUROPEAN JOURNAL OF PHYSICS PII: S0143-0807(04)76273-X A wave lab inside a coaxial cable JoãoMSerra,MiguelCBrito,JMaiaAlves and A M Vallera
CE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board
CE EMC Test Report APPLICANT EQUIPMENT BRAND NAME MODEL NAME : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board : Texas Instruments : WL1835MODCOM8B STANDARD : ETSI EN 301 489-1 V1.9.2
CHAPTER 6 INSTRUMENTATION AND MEASUREMENTS 6.1 MEASUREMENTS
CHAPTER 6 INSTRUMENTATION AND MEASUREMENTS 6.1 MEASUREMENTS Atmospheric electricity is a field that is very easy to get into because it does not require a large capital investment for measuring equipment.
EMC for test engineers by. Laplace Instruments Ltd. An introduction to the world of EMC compliance testing for engineers new to the topic.
EMC for test engineers by An introduction to the world of EMC compliance testing for engineers new to the topic. Index: Introduction Page 3 The EU Directive Page 3 The EMC Standards. Page 3 Compliance
BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date
Test Report for CE Report Number Applicant ESTCE0803-003 Company Name Address Product type Suprema Inc. 16F Parkview Office Tower, Jeongja-dong, Bundang-gu,Seongnam, Gyeonggi, 463-863 Korea FINGERPRINT
1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING
1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L APPLICATION NOTE AN-357 1.0 INTRODUCTION In today's highly competitive market, high quality of service, QOS, and reliability is
AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation
AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation Abstract EMC compatibility is becoming a key design
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
Coupling/Decoupling Networks (CDN)
Coupling/Decoupling Networks (CDN) For immunity testing according to IEC / EN 61000-4-6 Immunity testing CDNs are the preferred coupling and decoupling devices, for reasons of test reproducibility and
Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise
TDK EMC Technology Product Section Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise TDK Shonai Corporation Satoru Saito Reduce Emission Noise from Cables Even if an electronic
MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
DATA SHEET DVI - HDCP Extension Cable
DATA SHEET DVI - HDCP Extension Cable Contents Description Features Absolute Maximum Ratings Recommended Operating Conditions Electrical Power Supply Characteristics Receiver Electrical Interface Specifications
CONDUCTED EMISSION MEASUREMENT OF A CELL PHONE PROCESSOR MODULE
Progress In Electromagnetics esearch C, Vol. 42, 191 203, 2013 CONDUCTED EMISSION MEASUEMENT OF A CELL PHONE POCESSO MODULE Fayu Wan *, Junxiang Ge, and Mengxiang Qu Nanjing University of Information Science
White Paper: Electrical Ground Rules
Acromag, Incorporated 30765 S Wixom Rd, Wixom, MI 48393 USA Tel: 248-295-0880 Fax: 248-624-9234 www.acromag.com White Paper: Electrical Ground Rules Best Practices for Grounding Your Electrical Equipment
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
Signal Integrity: Tips and Tricks
White Paper: Virtex-II, Virtex-4, Virtex-5, and Spartan-3 FPGAs R WP323 (v1.0) March 28, 2008 Signal Integrity: Tips and Tricks By: Austin Lesea Signal integrity (SI) engineering has become a necessary
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer
APSYN420A/B Specification 1.24 0.65-20.0 GHz Low Phase Noise Synthesizer 1 Introduction The APSYN420 is a wideband low phase-noise synthesizer operating from 0.65 to 20 GHz. The nominal output power is
DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D
ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &
Grounding Demystified
Grounding Demystified 3-1 Importance Of Grounding Techniques 45 40 35 30 25 20 15 10 5 0 Grounding 42% Case 22% Cable 18% Percent Used Filter 12% PCB 6% Grounding 42% Case Shield 22% Cable Shielding 18%
Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions
PreCompliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions D. Schneider 1*, S. Tenbohlen 1, W. Köhler 1 1 Institute of Power Transmission and
TECHNICAL TBR 12 BASIS for December 1993 REGULATION
TECHNICAL TBR 12 BASIS for December 1993 REGULATION Source: ETSI TC-BT Reference: DTBR/BT-02036 ICS: 33.040.40 Key words: ONP, leased lines, D2048U Business Telecommunications (BT); Open Network Provision
TECHNICAL TBR 14 BASIS for April 1994 REGULATION
TECHNICAL TBR 14 BASIS for April 1994 REGULATION Source: ETSI TC-BTC Reference: DTBR/BTC-02038 ICS: 33.040.40 Key words: ONP, leased line Business TeleCommunications (BTC); 64 kbit/s digital unrestricted
Rules for Classification and Construction Additional Rules and Guidelines
VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 2 Test Requirements for Electrical / Electronic Equipment and Systems Edition
MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING
TESTING CERT #803.01, 803.02, 803.05, 803.06 MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING DATE OF
Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content
Charged cable event David Pommerenke, [email protected], 916 785 4550 Last update: Feb.23, 2001 Content Goal Energy sources, which may lead to CDE. Complexity of the different discharge modes. Possible
LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium
LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE Velleman Legen Heirweg 33 9890 Gavere Belgium SPECIFICATIONS DIGITAL MULTIMETER 3 1/2 backlit LCD Automatic polarity indication DC voltage 200mV to 600V in 5 steps
WIRELESS MAGNETIC CONTACT
WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:
Generic - Hearing Loop - (AFILS) U.S. System Specification
This document is a generic specification for any Hearing Loop (Audio Frequency Induction Loop System). For the remainder of the document, we will refer to using the term Hearing Loop rather than Audio
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab
How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab For questions and details contact Dennis at [email protected] Introduction The CE mark (an acronym for the French
Broadband over Power Line (BPL) Test Procedures and Equipment Authorization
Broadband over Power Line (BPL) Test Procedures and Equipment Authorization Andy Leimer Equipment Authorization Branch Federal Communications Commission Office of Engineering and Technology Laboratory
Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules
Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Craig W. Fanning Elite Electronic Engineering, Inc. 1516 Centre Circle Downers
EMC Standards: Standards of good EMC engineering
Electromagnetic Compatibility (EMC) IEEE Definition Origin, control, and measurement of electromagnetic effects on electronic and biologic systems. IEEE EMC Society Areas of Interest EMC Standards: Standards