1 Centration Measurement, Alignment and Assembly of Infrared Lenses Contents Centration Measurement of Infrared Lenses 2 Special Considerations for Centration Measurement of Infrared Lenses 2 Infrared Spectral Ranges 2 Differences to VIS from the Operator Side 3 Differences to VIS from a Technical Perspective 3 Measurement Examples for Infrared Lenses 4 Centration Testing of Highly Sensitive Single Lenses 5 Centration Measurement of Infrared Single Lenses with Plane Reference Flange 6 Centration Testing of Aspherical Lens Surfaces 7 Characterization of Complex Lens Systems 9 1/9
2 Centration Measurement of Infrared Lenses This whitepaper focusses on centration measurement of infrared lenses: it describes the special considerations for the centration measurement of infrared lenses and provides a detailed description of typical applications for infrared lens measurement. The majority of centration measurements can be carried out with a more cost-effective visual measurement head. An infrared measurement head is only required for the measurement of optical systems or for measurements in transmission. As the whitepaper focuses on infrared lens applications the general description of centration measurement is not part of this whitepaper. Please feel free to visit our website to get more information about centration measurement and low-coherence interferometry. Special Considerations for Centration Measurement of Infrared Lenses For testing single lenses and completed assemblies that are only transparent in the infrared range, TRIOPTICS provides measurement heads specifically designed for the infrared wavelength ranges that are equipped with focal-plane array infrared image sensors for ease of use. Typical applications are e.g. testing of lenses and assemblies for thermal imaging, military applications or industrial process control made from lens materials like e.g. Ge, Si, ZnSe, ZnS or CaF2. Infrared Spectral Ranges The infrared wavelength range is divided in three distinct ranges for imaging applications. These bands exhibit high transmission of light through air and are separated by strongly absorbing bands in the spectrum. The three imaging infrared ranges are: short wave infrared (SWIR) from µm, medium wave infrared (MWIR) from 3-5 µm and finally long wave infrared (LWIR) from 8-12 µm wavelength. Due to limitations in detector technology, so far no image sensor can cover all three wavelength ranges, however a LWIR system can also cover most MWIR lenses and vice versa. 2/9
3 For an overview about compatible materials and the wavelength regions covered by the * Comparison of transparent regions of typical infrared lens materials and the regions covered by available OptiCentric measurement heads. *Depending on doping level and dopant type available measurement heads please refer to adjactent drawing below. Silicon is a special case as the transparent region depends on the doping level and dopant type, so a LWIR head might be a suitable depending on application. Differences to VIS from the Operator Side In contrast to VIS systems, the light emitted from the focused autocollimator head cannot be seen by the naked eye which is however no problem in practice for aligning the sample. Apart from that, the operation of the infrared systems is not different to the VIS systems, so a user can be quickly trained for a new wavelength range. Differences to VIS from a Technical Perspective From a technical side, apart from using suitable optics and illumination sources in the measurement heads, the most important difference between visual and infrared range is that in the infrared range every object, including the sample, emits light in this wavelength region, so the instrument needs to compensate for the thermal background before taking a measurement. This is done automatically by the software and requires no operator intervention. Also, the contrast between background and illuminated areas is lower than in 3/9
4 the VIS, so specialized image processing algorithms are used to reach the required high resolution. OptiCentric in the standard reflection mode relies on back-reflection from the lens surface, so the light intensity of the reflected reticule image strongly depends on the type of coating used. Typically, all infrared imaging lenses are AR-coated, however there is a wide variation in efficiency which the instruments compensates by adjusting illumination power and shutter times where available. In general, the typical accuracy of the centration error measurement in IR range is approximately 1 µm, which is due to the longer wavelength and larger pixel size of the cameras used in the autocollimators in the IR range. Measurement Examples for Infrared Lenses In order to understand the measurement and assembly of different infrared lenses, some typical measurement, alignment and assembly tasks and their solutions are presented below. Centration Testing of Single Lenses Centration testing of non-vistransparent or transparent single Measurement of an infrared lens on lens rotation device lenses with OptiCentric is the described measurement task. The required instrument is equipped with a lens rotation device and a visual measurement head. The lens under test is placed onto the ring chuck support of the lens rotation device. This fixes the center of symmetry of the bottom surface in space. When the lens rotates with its edge against the V-block, the lens rotation axis is given by the geometrical center of the circumference and the center of curvature of the bottom surface. In this way the rotation axis corresponds directly to the reference axis for the determination of the wedge error. So the remaining parameter to be measured is the center of curvature position of the top surface, which can easily be tested by OptiCentric in reflection mode. Advantages of the Single lens centration testing in reflection mode with an OptiCentric System with the lens rotation device allows the evaluation of infrared lenses with a cost-effective instrument without the need for expensive infrared devices. OptiCentric with lens rotation device with vacuum chuck 4/9
5 Centration Testing of Highly Sensitive Single Lenses The easiest way to protect highly sensitive lenses like calcium fluoride lenses against scratches is to reduce handling during the production and testing process. The OptiCentric Dual instrument in combination with an air bearing and a non-contact distance sensor fulfills this requirement, instead of using the lens rotation device with V-block. An OptiCentric Instrument with cost-effective visual measuring heads is used regardless of the material properties of the lens under test. The lens is carefully placed in the lens holder. During the measurement the dual autocollimators measure the center of curvature positions of the top and bottom surfaces; the distance sensor measures the radial run-out of the lens edge. In the analysis, the software determines the reference axis from the center of the circumference and the bottom surface. The measured offset of the top surface to this axis gives the lens centration error. For lenses that are Measurement the edge of a highly sensitive lens with a distance sensor transparent in the VIS range the centration error can alternatively be measured in transmission. Therefore, the top autocollimator measures the run-out of the focus spot when the lens under test is illuminated with collimated light by the bottom (auto-) collimator. A minimum of handling protects the sensitive surfaces of the lens. Both surfaces are measured in one step with cost-effective visual measurement heads. OptiCentric 100 Dual or OptiCentric 300 Dual with distance sensor 5/9
6 Centration Measurement of Infrared Single Lenses with Plane Reference Flange Lenses with a plane reference flange are often used in infrared optical systems. The preferred instrument to measure these lenses is the OptiCentric Dual, with two visual measurement heads and lens rotation device with vacuum chuck. The lens is placed with the support flanges onto the ring chuck and rotated against the V-block. The upper autocollimator focuses in the center of curvature of the top surface. The lower autocollimator focuses in the center of curvature of the lower surface. Thus, the measurement is accomplished in reflection. In this case the reference axis Lens with plane reference flange is given by the center of symmetry of the circumference and the normal of the support flange. The result of this measurement gives information about the centration errors of both surfaces with respect to the reference. For VIS-transparent lenses the centration can be measured in transmission as well. Both surfaces are measured in one step with cost-effective visual measurement heads and lens rotation device with vacuum chuck. OptiCentric Dual with vacuum chuck 6/9
7 Centration Testing of Aspherical Lens Surfaces The use of aspheric surfaces in the design of optical systems makes it possible to achieve better spot size performance, or alternatively to achieve similar performance while using fewer elements in the system. Therefore, especially for infrared optics, aspherical surfaces are commonly applied. Aspherical infrared lenses are preferably measured with an OptiCentric Dual instrument equipped with AspheroCheck module. This configuration achieves the best results and allows for simple handling. The lens is placed in the lens holder with the aspherical surface to the top. During the measurement the lens rotates and the three parameters required for centration testing are measured: Center of curvature position of the spherical bottom surface Paraxial center of curvature position of the top aspherical surface Eccentricity of the outer edge of the aspherical surface under rotation These three measurements are taken at the same time during the rotation of the lens: The lower measurement head focuses in the center of curvature of the spherical bottom surface and measures its centration. The centration of the paraxial area of the upper Measuring an aspherical lens surface is measured with the help of the upper measuring head in reflection mode as well. Third, the AspheroCheck module measures the eccentricity of the aspherical surface. The results of these measurements of aspherical infrared lenses give information about: Orientation of the asphere with respect to the primary reference axis of the measurement system (corresponding to the axis of rotation) Orientation of the top asphere with respect to the axis of bottom sphere and center of circumference In case of a double-sided asphere: relative orientation of the two aspherical surfaces OptiCentric 100 Dual or OptiCentric 300 Dual with AspheroCheck module 7/9
8 Assembly of Infrared Optical Systems The precise assembly of lenses in a barrel is a decisive step during the production of objective lenses. An OptiCentric instrument with an air bearing and distance sensor greatly improves the accuracy of the production process and the performance of the final product. Measurement & Assembly: At first the barrel axis is aligned to the axis of the rotary air bearing using a distance sensor (e.g. a lever gage). The first lens is placed into the barrel. The autocollimator measures the center of curvature position of the top surface with respect to the reference axis. Then the lens can be realigned in magnitude and direction according to the measured values. Depending on the mechanical design of the sample the lens is fixed in position by using retaining rings or glue, for example. This procedure is repeated iteratively for all further lens elements until the optical system is completed. If a VIS&IR measuring head is used, the assembly can be done in the VIS range for highest precision and the final inspection is done I n the IR range. An optimized mechanical alignment of optical infrared systems is achieved using an OptiCentric instrument. Thanks to the step-by-step measurement and alignment procedure of freely accessible lens elements, a cost-effective visual measurement head can be used regardless of the material properties of the lens. If the assembly and final inspection of the lens is required on one workplace an instrument with VIS&IR measuring head is required. OptiCentric 3D 100 or OptiCentric 3D 300 with distance sensor, OptiCentric 3D system with VIS&IR measuring head OptiCentric MAX 300 with VIS&IR measuring head 8/9
9 Characterization of Complex Lens Systems In the quality inspection of lens systems, testing solely the final optical performance is often not sufficient as it does not reveal the causes of potential substandard performance. Instead, a full opto-mechanical characterization of the samples is required to identify potential issues in the assembly process. An OptiCentric 3D instrument equipped with an infrared measurement head or VIS&IR measuring head, rotary air bearing, tilt and translation table, and MultiLens and OptiSurf low-coherence interferometer modules fulfills these requirements. After the objective lens to be tested has been placed onto the sample table, the center of curvature positions of all single lens surfaces are measured following the MultiLens concept. Therefore, the autocollimator iteratively focuses into the center of curvature positions (or their image positions according to the MultiLens calculation) of all sample surfaces and measures their relative position with respect to the reference axis. In the subsequent analysis, the relative orientation of the single element s or group s axis is evaluated with respect to each other or a mechanical barrel axis. As the precise coincidence of sample and measurement axis is a particular requirement for the measurement of the center thickness and air gaps, data from centration testing is used for the precise alignment of the sample axis with the tilt and translation table. Then, the axial lens surface positions are measured. OptiCentric with IR measuring head OptiCentric 3D 100 with infrared measurement head is the only instrument which accomplishes the complete opto-mechanical characterization of infrared lens systems and delivers detailed information about the assembly of the instrument. OptiCentric 3D with IR, OptiCentric 3D 300 Infrared or OptiCentric 3D Dual If the objective lens only consists of lenses that are transparent in the visible range, standard VIS measurement heads can be used. 9/9
ENGINEERING METROLOGY
ENGINEERING METROLOGY ACADEMIC YEAR 92-93, SEMESTER ONE COORDINATE MEASURING MACHINES OPTICAL MEASUREMENT SYSTEMS; DEPARTMENT OF MECHANICAL ENGINEERING ISFAHAN UNIVERSITY OF TECHNOLOGY Coordinate Measuring
More informationSP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)
SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE) We greatly appreciate your purchase of this Tamron lens. The Tamron SP AF 300mm F/2.8 LD [IF] is a fast telephoto lens developed for Canon AF single-reflex
More informationChapter 17: Light and Image Formation
Chapter 17: Light and Image Formation 1. When light enters a medium with a higher index of refraction it is A. absorbed. B. bent away from the normal. C. bent towards from the normal. D. continues in the
More informationFig.1. The DAWN spacecraft
Introduction Optical calibration of the DAWN framing cameras G. Abraham,G. Kovacs, B. Nagy Department of Mechatronics, Optics and Engineering Informatics Budapest University of Technology and Economics
More informationSynthetic Sensing: Proximity / Distance Sensors
Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,
More informationAP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light Name: Period: Date: MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. 1) Reflection,
More informationDOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND
DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND THE THREE-DIMENSIONAL DISTRIBUTION OF THE RADIANT FLUX DENSITY AT THE FOCUS OF A CONVERGENCE BEAM
More informationCare and Use of the Compound Microscope
Revised Fall 2011 Care and Use of the Compound Microscope Objectives After completing this lab students should be able to 1. properly clean and carry a compound and dissecting microscope. 2. focus a specimen
More informationEXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab
EXPERIMENT O-6 Michelson Interferometer Abstract A Michelson interferometer, constructed by the student, is used to measure the wavelength of He-Ne laser light and the index of refraction of a flat transparent
More informationLongwave IR focal-plane binary optics
Longwave IR focal-plane binary optics Z. Sikorski, H. Polakowski Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Str., -98 Warsaw, e-mail: zsikorsk@wat.waw.pl Abstract In
More informationAutomatic and Objective Measurement of Residual Stress and Cord in Glass
Automatic and Objective Measurement of Residual Stress and Cord in Glass GlassTrend - ICG TC15/21 Seminar SENSORS AND PROCESS CONTROL 13-14 October 2015, Eindhoven Henning Katte, ilis gmbh copyright ilis
More informationID Objective Requirements Description of Test Date & Examiner 15 Verify that the optics?? OMC
NAOMI OMC/NCU Acceptance Tests at the University of Durham ATC Document number AOW/GEN/RAH/15.0/06/00 OMC/NCU acceptance tests DRAFT (Version date: 2 nd June 2000) wht-naomi-44 The ID numbers are those
More informationHelium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment.
Helium-Neon Laser Experiment objectives: assemble and align a 3-mW HeNe laser from readily available optical components, record photographically the transverse mode structure of the laser output beam,
More informationPhysics 441/2: Transmission Electron Microscope
Physics 441/2: Transmission Electron Microscope Introduction In this experiment we will explore the use of transmission electron microscopy (TEM) to take us into the world of ultrasmall structures. This
More informationDEFINING AND MEASURING PHYSICAL PARAMETERS OF PC POLISHED FIBER OPTIC CONNECTORS
DEFINING AND MEASURING PHYSICAL PARAMETERS OF PC POLISHED FIBER OPTIC CONNECTORS Eric A. Norland Norland Products, Inc. PO Box 637, Building100 2540 Route 130 Cranbury, NJ 08512 www.norlandprod.com ABSTRACT
More informationSP AF 17~50 mm F/2.8 XR Di-II LD Aspherical [IF] (Model A16)
SP AF 17~50 mm F/2.8 XR Di-II LD Aspherical [IF] (Model A16) Thank you for purchasing the Tamron lens as the latest addition to your photographic equipment. Di II lens (Digitally Intigrated) series are
More informationFTIR Instrumentation
FTIR Instrumentation Adopted from the FTIR lab instruction by H.-N. Hsieh, New Jersey Institute of Technology: http://www-ec.njit.edu/~hsieh/ene669/ftir.html 1. IR Instrumentation Two types of instrumentation
More informationRL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G
Auto-Levelling Rotary Laser Level RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G 77-496 / 77-429 / 77-439 / 77-497 / 77-427/ 77-441 Please read these instructions before operating the product Auto-Levelling
More informationChapter 6 Telescopes: Portals of Discovery. How does your eye form an image? Refraction. Example: Refraction at Sunset.
Chapter 6 Telescopes: Portals of Discovery 6.1 Eyes and Cameras: Everyday Light Sensors Our goals for learning:! How does your eye form an image?! How do we record images? How does your eye form an image?
More informationChapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012
Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012 Figure 1.1 illustrates the parts of an upright compound microscope and indicates the terminology that I use in these notes. Figure 1.1. Parts of a Compound
More informationWAVELENGTH OF LIGHT - DIFFRACTION GRATING
PURPOSE In this experiment we will use the diffraction grating and the spectrometer to measure wavelengths in the mercury spectrum. THEORY A diffraction grating is essentially a series of parallel equidistant
More informationAlignement of a ring cavity laser
Alignement of a ring cavity laser 1 Introduction This manual describes a procedure to align the cavity of our Ti:Sapphire ring laser and its injection with an Argon-Ion pump laser beam. The setup is shown
More informationOptical Standards. John Nichol BSc MSc
Optical Standards John Nichol BSc MSc The following notes are presented to explain: Spherical Aberration The Airy Disk Peak to Valley, RMS and Strehl Ratio Standards of Optics produced by Nichol Optical
More information3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY
3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY Prepared by Duanjie Li, PhD & Andrea Novitsky 6 Morgan, Ste156, Irvine CA 92618 P: 949.461.9292 F: 949.461.9232 nanovea.com Today's standard
More informationApplication Report: Running µshape TM on a VF-20 Interferometer
: Running µshape TM on a VF-20 Interferometer General This report describes how a fiber interferometer from Arden Photonics Ltd was used together with the µshape TM Generic software package. The VF-20
More informationConvex Mirrors. Ray Diagram for Convex Mirror
Convex Mirrors Center of curvature and focal point both located behind mirror The image for a convex mirror is always virtual and upright compared to the object A convex mirror will reflect a set of parallel
More informationTube Control Measurement, Sorting Modular System for Glass Tube
Tube Control Measurement, Sorting Modular System for Glass Tube Tube Control is a modular designed system of settled instruments and modules. It comprises measuring instruments for the tube dimensions,
More informationMeasuring Miniature Lens Radius of Curvature and Refractive Index with White Light Optical Profiler
Measuring Miniature Lens Radius of Curvature and Refractive Index with White Light Optical Profiler Introduction For miniature lenses with size of few millimeters or sub-millimeter, it is difficult to
More informationTheremino System Theremino Spectrometer Technology
Theremino System Theremino Spectrometer Technology theremino System - Theremino Spectrometer Technology - August 15, 2014 - Page 1 Operation principles By placing a digital camera with a diffraction grating
More informationThe Wide Field Cassegrain: Exploring Solution Space
The Wide Field Cassegrain: Exploring Solution Space Peter Ceravolo Ceravolo Optical Systems www.ceravolo.com peter@ceravolo.com Abstract This article illustrates the use of an internal aperture stop in
More informationAF 70~300 mm F/4-5.6 Di LD Macro 1:2 (Model A17)
AF 70~300 mm F/4-5.6 Di LD Macro 1:2 (Model A17) Thank you for purchasing the Tamron lens as the latest addition to your photographic equipment. Di II lens (Digitally Integrated) series are designed for
More informationOptical System Design
Optical System Design Robert E. Fischer CEO, OPTICS 1, Incorporated Biljana Tadic-Galeb Panavision Paul R. Yoder Consultant With contributions by Ranko Galeb Bernard C.Kress, Ph.D. Stephen C. McClain,
More informationWOOD WEAR TESTING USING TRIBOMETER
WOOD WEAR TESTING USING TRIBOMETER Prepared by Duanjie Li, PhD 6 Morgan, Ste156, Irvine CA 92618 P: 949.461.9292 F: 949.461.9232 nanovea.com Today's standard for tomorrow's materials. 2015 NANOVEA INTRO
More informationWHITE PAPER. Are More Pixels Better? www.basler-ipcam.com. Resolution Does it Really Matter?
WHITE PAPER www.basler-ipcam.com Are More Pixels Better? The most frequently asked question when buying a new digital security camera is, What resolution does the camera provide? The resolution is indeed
More informationFlat-Field IR Mega-Pixel Lens
Flat-Field Mega-Pixel Lens Series Flat-Field Mega-Pixel Lens Flat-Field Mega-Pixel Lens 20.ver.02 E Specifications and Lineup Full MP Image Model Imager Size Mount Focal Length Aperture Range Zoom Ratio
More informationLBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes
LBS-300 Beam Sampler for C-mount Cameras P/N SP90183, SP90184, SP90185 and SP90186 YAG Focal Spot Analysis Adapter P/N SP90187, SP90188, SP90189, SP90190, SP90191 User Notes Ophir-Spiricon Inc. 60 West
More informationGeometric Optics Converging Lenses and Mirrors Physics Lab IV
Objective Geometric Optics Converging Lenses and Mirrors Physics Lab IV In this set of lab exercises, the basic properties geometric optics concerning converging lenses and mirrors will be explored. The
More informationHygro-Thermometer + InfraRed Thermometer Model RH101
User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative
More informationParts List. The HyperStar Lens Assembly includes three pieces: HyperStar Lens Secondary Mirror Holder Counterweight
The HyperStar Lens allows CCD imaging at f/2.3 with compatible Celestron 9.25 Schmidt-Cassegrain telescopes and compatible CCD cameras. These instructions show the proper methods for installing the HyperStar
More informationGeometric Camera Parameters
Geometric Camera Parameters What assumptions have we made so far? -All equations we have derived for far are written in the camera reference frames. -These equations are valid only when: () all distances
More informationLenses and Telescopes
A. Using single lenses to form images Lenses and Telescopes The simplest variety of telescope uses a single lens. The image is formed at the focus of the telescope, which is simply the focal plane of the
More information18-270mm F/3.5-6.3 Di II VC PZD for Canon, Nikon (Model B008) 18-270mm F/3.5-6.3 Di II PZD for Sony (Model B008)
R 18-270mm F/3.5-6.3 Di II VC PZD for Canon, Nikon (Model B008) 18-270mm F/3.5-6.3 Di II PZD for Sony (Model B008) Thank you for purchasing the Tamron lens as the latest addition to your photographic equipment.
More informationMaking Better Medical Devices with Multisensor Metrology
Making Better Medical Devices with Multisensor Metrology by Nate J. Rose, Chief Applications Engineer, Optical Gaging Products (OGP) Multisensor metrology is becoming a preferred quality control technology
More information5.3 Cell Phone Camera
164 Chapter 5 5.3 Cell Phone Camera The next design example we discuss is a cell phone camera. These systems have become quite popular, to the point that it is often more difficult to purchase a cell phone
More informationSimplifying Opto- Mechanical Product Development: How a new product reduces cost, stress, and time to market
Simplifying Opto- Mechanical Product Development: How a new product reduces cost, stress, and time to market Innovation in optical design is exploding. From cell phone cameras to space telescopes, driverless
More informationRAY TRACING UNIFIED FIELD TRACING
RAY TRACING Start to investigate the performance of your optical system using 3D ray distributions, dot diagrams of ray positions and directions, and optical path length. GEOMETRIC FIELD TRACING Switch
More informationTECNOTTICA CONSONNI SRL CERTIFIED QUALITY MANAGEMENT SYSTEM COMPANY BY DNV UNI EN ISO 9001:2008
TECNOTTICA CONSONNI SRL CERTIFIED QUALITY MANAGEMENT SYSTEM COMPANY BY DNV UNI EN ISO 9001:2008 OUR COMPANY Tecnottica Consonni is an optical manufacturing company specialized since 1957 in the manufacture
More informationIR Window Transmittance Temperature Dependence
IR Window Transmittance Temperature Dependence Robert P. Madding, Infrared Training Center, FLIR Systems, Inc. ABSTRACT While fluoride-type IR windows are inexpensive and have good transmittance in the
More information1051-232 Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002
05-232 Imaging Systems Laboratory II Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002 Abstract: For designing the optics of an imaging system, one of the main types of tools used today is optical
More informationRealization of a UV fisheye hyperspectral camera
Realization of a UV fisheye hyperspectral camera Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM Outline Purpose of the instrument Required specs Hyperspectral technique Optical
More informationField Application Note
Field Application Note Reverse Dial Indicator Alignment RDIA Mis-alignment can be the most usual cause for unacceptable operation and high vibration levels. New facilities or new equipment installations
More informationDynamic IR Scene Projector Based Upon the Digital Micromirror Device
Dynamic IR Scene Projector Based Upon the Digital Micromirror Device D. Brett Beasley, Matt Bender, Jay Crosby, Tim Messer, and Daniel A. Saylor Optical Sciences Corporation www.opticalsciences.com P.O.
More informationINFRARED PARTS MANUAL
INFRARED PARTS MANUAL PIR325 FL65 GLOLAB CORPORATION Thank you for buying our Pyroelectric Infrared components. The goal of Glolab is to produce top quality electronic kits, products and components. All
More informationMicro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity
Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Innovation with Integrity Micro-CT 3D Microscopy Using Micro-CT for SEM Micro-CT for SEM
More informationUnderstanding astigmatism Spring 2003
MAS450/854 Understanding astigmatism Spring 2003 March 9th 2003 Introduction Spherical lens with no astigmatism Crossed cylindrical lenses with astigmatism Horizontal focus Vertical focus Plane of sharpest
More informationGRID AND PRISM SPECTROMETERS
FYSA230/2 GRID AND PRISM SPECTROMETERS 1. Introduction Electromagnetic radiation (e.g. visible light) experiences reflection, refraction, interference and diffraction phenomena when entering and passing
More informationRec. ITU-R F.699-5 1 RECOMMENDATION ITU-R F.699-5 *
Rec. ITU-R F.699-5 1 RECOMMENATION ITU-R F.699-5 * REFERENCE RAIATION PATTERNS FOR LINE-OF-SIGHT RAIO-RELAY SYSTEM ANTENNAS FOR USE IN COORINATION STUIES AN INTERFERENCE ASSESSMENT IN THE FREQUENCY RANGE
More informationRodenstock Photo Optics
Apo-Sironar-S Apo-Macro-Sironar Apo-Grandagon Grandagon-N Accessories: Center filters Accessories: Focus-Mount Lenses for Analog Professional Photography Even in the age of digital photography, the professional
More informationwaves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object
PHYS1000 Optics 1 Optics Light and its interaction with lenses and mirrors. We assume that we can ignore the wave properties of light. waves rays We represent the light as rays, and ignore diffraction.
More informationMEASUREMENT OF END FACE GEOMETRY ON FIBER OPTIC TERMINI...2
MEASUREMENT OF END FACE GEOMETRY ON FIBER OPTIC TERMINI...2 IMPORTANCE OF END FACE GEOMETRY...2 FIBER OPTIC CONNECTOR END FACE GEOMETRY MEASUREMENT TECHNIQUES...2 INTERFEROMETRIC MICROSCOPE TYPES...3 MEASUREMENT
More informationDefog Image Processing
Introduction Expectations for a camera s performance, no matter the application, are that it must work and provide clear usable images, regardless of any environmental or mechanical challenges the camera
More informationFSI Machine Vision Training Programs
FSI Machine Vision Training Programs Table of Contents Introduction to Machine Vision (Course # MVC-101) Machine Vision and NeuroCheck overview (Seminar # MVC-102) Machine Vision, EyeVision and EyeSpector
More informationTHE EFFECTS OF TEMPERATURE VARIATION ON SINGLE-LENS-REFLEX DIGITAL CAMERA CALIBRATION PARAMETERS
Coission V Symposium, Newcastle upon Tyne, UK. 2010 THE EFFECTS OF TEMPERATURE VARIATION ON SINGLE-LENS-REFLEX DIGITAL CAMERA CALIBRATION PARAMETERS M. J. Smith *, E. Cope Faculty of Engineering, The University
More informationSTAAR Science Tutorial 30 TEK 8.8C: Electromagnetic Waves
Name: Teacher: Pd. Date: STAAR Science Tutorial 30 TEK 8.8C: Electromagnetic Waves TEK 8.8C: Explore how different wavelengths of the electromagnetic spectrum such as light and radio waves are used to
More informationAgilent AEDB-9140 Series Three Channel Optical Incremental Encoder Modules with Codewheel, 100 CPR to 500 CPR Data Sheet
Agilent AEDB-9140 Series Three Channel Optical Incremental Encoder Modules with Codewheel, 100 CPR to 500 CPR Data Sheet Description The AEDB-9140 series are three channel optical incremental encoder modules
More informationAnamorphic imaging with three mirrors: a survey
Anamorphic imaging with three mirrors: a survey Joseph M. Howard Optics Branch (Code 551), NASA Goddard Space Flight Center, Greenbelt, MD 20771 Ph: 301-286-0690 Fax: 301-286-0204 Joseph.M.Howard@nasa.gov
More informationEndoscope Optics. Chapter 8. 8.1 Introduction
Chapter 8 Endoscope Optics Endoscopes are used to observe otherwise inaccessible areas within the human body either noninvasively or minimally invasively. Endoscopes have unparalleled ability to visualize
More informationBARREL ALIGNMENT- A CRITICAL FACTOR IN REDUCING EXTRUDER WEAR
BARREL ALIGNMENT- A CRITICAL FACTOR IN REDUCING EXTRUDER WEAR Jeff A. Myers- BARR Inc., Onsted, MI Mike Puhalla Milacron, Batavia, OH Abstract As processors increase the demand on the extruder for increased
More informationAn Introduction to the MTG-IRS Mission
An Introduction to the MTG-IRS Mission Stefano Gigli, EUMETSAT IRS-NWC Workshop, Eumetsat HQ, 25-0713 Summary 1. Products and Performance 2. Design Overview 3. L1 Data Organisation 2 Part 1 1. Products
More informationExperiment 3 Lenses and Images
Experiment 3 Lenses and Images Who shall teach thee, unless it be thine own eyes? Euripides (480?-406? BC) OBJECTIVES To examine the nature and location of images formed by es. THEORY Lenses are frequently
More informationEfficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red
Changing the economics of space Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red J. Fernandez-Saldivar 1, F. Culfaz 1,
More informationYOUR PARTNER FOR THERMAL IMAGING SECURITY APPLICATIONS
YOUR PARTNER FOR THERMAL IMAGING SECURITY APPLICATIONS About Opgal Security Products OPGAL is a leading global manufacturer of innovative thermal imaging cameras and engines. For over 25 years Opgal s
More informationIndustrial Robotics. Training Objective
Training Objective After watching the program and reviewing this printed material, the viewer will learn the basics of industrial robot technology and how robots are used in a variety of manufacturing
More informationMolded Infrared Optics 03.06.2015
Molded Infrared Optics 03.06.2015 Overview 1. Company 2. Basics precision glass molding 3. Molding of chalcogenide glass 4. Chalcogenide glass comparison with cristalline materials 5. Design recommendations
More informationLaboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014
Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014 Introduction Following our previous lab exercises, you now have the skills and understanding to control
More informationFirst let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between
Optical Differences Between Telescopes and Microscopes Robert R. Pavlis, Girard, Kansas USA icroscopes and telescopes are optical instruments that are designed to permit observation of objects and details
More informationv = fλ PROGRESSIVE WAVES 1 Candidates should be able to :
PROGRESSIVE WAVES 1 Candidates should be able to : Describe and distinguish between progressive longitudinal and transverse waves. With the exception of electromagnetic waves, which do not need a material
More informationIntegration of a passive micro-mechanical infrared sensor package with a commercial smartphone camera system
1 Integration of a passive micro-mechanical infrared sensor package with a commercial smartphone camera system Nathan Eigenfeld Abstract This report presents an integration plan for a passive micro-mechanical
More informationRESULTS FROM A SIMPLE INFRARED CLOUD DETECTOR
RESULTS FROM A SIMPLE INFRARED CLOUD DETECTOR A. Maghrabi 1 and R. Clay 2 1 Institute of Astronomical and Geophysical Research, King Abdulaziz City For Science and Technology, P.O. Box 6086 Riyadh 11442,
More informationPHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS
PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS 1. Photons 2. Photoelectric Effect 3. Experimental Set-up to study Photoelectric Effect 4. Effect of Intensity, Frequency, Potential on P.E.
More informationIntroduction to Optics
Second Edition Introduction to Optics FRANK L. PEDROTTI, S.J. Marquette University Milwaukee, Wisconsin Vatican Radio, Rome LENO S. PEDROTTI Center for Occupational Research and Development Waco, Texas
More informationDome Camera with IR Night Vision
Dome Camera with IR Night Vision Instruction Manual VER.:1.0, NO.: R040687/2 Thank you for purchasing our product. Before installing this camera, please read this instruction manual carefully to ensure
More informationHigh-resolution Imaging System for Omnidirectional Illuminant Estimation
High-resolution Imaging System for Omnidirectional Illuminant Estimation Shoji Tominaga*, Tsuyoshi Fukuda**, and Akira Kimachi** *Graduate School of Advanced Integration Science, Chiba University, Chiba
More informationIntroduction to Fourier Transform Infrared Spectrometry
Introduction to Fourier Transform Infrared Spectrometry What is FT-IR? I N T R O D U C T I O N FT-IR stands for Fourier Transform InfraRed, the preferred method of infrared spectroscopy. In infrared spectroscopy,
More informationVECTORAL IMAGING THE NEW DIRECTION IN AUTOMATED OPTICAL INSPECTION
VECTORAL IMAGING THE NEW DIRECTION IN AUTOMATED OPTICAL INSPECTION Mark J. Norris Vision Inspection Technology, LLC Haverhill, MA mnorris@vitechnology.com ABSTRACT Traditional methods of identifying and
More informationGeometry and dimensional tolerances of engine bearings
Geometry and dimensional tolerances of engine bearings Dr. Dmitri Kopeliovich (Research & Development Manager.) 1. Hydrodynamic lubrication Engine bearings operate mostly in the hydrodynamic regime of
More informationLaue lens for Nuclear Medicine
Laue lens for Nuclear Medicine PhD in Physics Gianfranco Paternò Ferrara, 6-11-013 Supervisor: prof. Vincenzo Guidi Sensors and Semiconductors Lab, Department of Physics and Earth Science, University of
More informationHello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light
Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light generation from a semiconductor material, LED chip technology,
More informationHIGH-PERFORMANCE INSPECTION VEHICLE FOR RAILWAYS AND TUNNEL LININGS. HIGH-PERFORMANCE INSPECTION VEHICLE FOR RAILWAY AND ROAD TUNNEL LININGS.
HIGH-PERFORMANCE INSPECTION VEHICLE FOR RAILWAYS AND TUNNEL LININGS. HIGH-PERFORMANCE INSPECTION VEHICLE FOR RAILWAY AND ROAD TUNNEL LININGS. The vehicle developed by Euroconsult and Pavemetrics and described
More informationThe infrared camera NEC Thermo tracer TH7102WL (1) (IR
PERIODICUM BIOLOGORUM UDC 57:61 VOL. 108, No 4,????, 2006 CODEN PDBIAD ISSN 0031-5362 Original scientific paper ThermoWEB-Remote Control and Measurement of Temperature over the Web D. KOLARI] K. SKALA
More informationChoosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.
Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ., Raleigh, NC One vital step is to choose a transfer lens matched to your
More information4. CAMERA ADJUSTMENTS
4. CAMERA ADJUSTMENTS Only by the possibility of displacing lens and rear standard all advantages of a view camera are fully utilized. These displacements serve for control of perspective, positioning
More informationTS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions
TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 ENG Instructions Thank you for purchasing a Canon product. Canon s TS-E lenses are tilt-shift lenses designed for EOS cameras. The tilt-shift mechanism enables
More informationLenses and Apertures of A TEM
Instructor: Dr. C.Wang EMA 6518 Course Presentation Lenses and Apertures of A TEM Group Member: Anup Kr. Keshri Srikanth Korla Sushma Amruthaluri Venkata Pasumarthi Xudong Chen Outline Electron Optics
More informationProcedure: Geometrical Optics. Theory Refer to your Lab Manual, pages 291 294. Equipment Needed
Theory Refer to your Lab Manual, pages 291 294. Geometrical Optics Equipment Needed Light Source Ray Table and Base Three-surface Mirror Convex Lens Ruler Optics Bench Cylindrical Lens Concave Lens Rhombus
More informationExperiment 3: Magnetic Fields of a Bar Magnet and Helmholtz Coil
MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Physics 8.02 Spring 2009 Experiment 3: Magnetic Fields of a Bar Magnet and Helmholtz Coil OBJECTIVES 1. To learn how to visualize magnetic field lines
More informationCalibration of a High Dynamic Range, Low Light Level Visible Source
Calibration of a High Dynamic Range, Low Light Level Visible Source Joe LaVeigne a, Todd Szarlan a, Nate Radtke a a Santa Barbara Infrared, Inc., 30 S. Calle Cesar Chavez, #D, Santa Barbara, CA 93103 ABSTRACT
More informationLASER TO FIBER SOURCE COUPLERS APPLICATION NOTES
LASER TO FIBER SOURCE COUPLERS APPLICATION NOTES Laser To Fiber Coupler With Adjustable Focus Laser To Fiber Coupler With A Beam Splitter Laser To Fiber Coupler With A Shutter Application Notes OZ Optics
More informationNOVEL FOCUSING OPTICS FOR IR LASERS Paper 1504
NOVEL FOCUSING OPTICS FOR IR LASERS Paper 1504 Gary Herrit 1, Alan Hedges 1, Herman Reedy 1 1 II-VI Incorporated, 375 Saxonburg Blvd., Saxonburg, PA, 16056, USA Abstract Traditional focusing optics for