1 66, 87 /, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /4 & G / Compact design Easily interchangeable solenoid tandard manual override ll valves available with Ex protected coils (TEX or other international approvals) aintenance-free Technical features edium: Compressed air, filtered, lubricated or non-lubricated Operation: Indirect solenoid operated T-spool valves Operating pressure: iehe Ventilauswahl Port size: G /4, G / Orifice: 6 and mm Electrical connection: Connector acc.to DIN EN 75-8, orm and low direction: ixed ounting: Optional, preferably with solenoid on top luid/mbient temperature: C Depending on solenoid system ir supply must be dry enough to avoid ice formation at temperatures below + C. aterials: Housing: aluminium anodized Pilot flange: plastic (PO) eals: NR (Perbunan) Other versions available on request ow power Watt Other voltages dditional international approvals Pilot operated valves NPT threaded Temperature range up to - C Technical data / way ymbol Port size unction Operation/return low (l/min) Operating pressure (bar) witching time (ms) Weight without olenoid Dimension odel G /4 NC olenoid / ir spring..., *) G / NC olenoid/ir spring,5... 5, *) G /4 NO olenoid/ir spring..., *) G / NO olenoid/ir spring,5... 5, *) *) Exhaust port can not be throttled. *) Exhaust port can be throttled. 5/ way G /4 NC olenoid/olenoid... 5, *) G / NC olenoid/olenoid..., *) ymbol Port size unction Operation/return low (l/min) Operating pressure (bar) witching time (ms) Weight without olenoid Dimension odel 4 G /4 olenoid/ir spring..., G / olenoid/ir spring... 5, G /4 olenoid/olenoid... 5, G / olenoid/olenoid..., / N/en
2 66,87 Technical data 5/ way ymbol Port size unction Operation/return low Operating witching Weight without Dimension odel (l/min) pressure (bar) time (ms) olenoid G /4 COE olenoid/olenoid G / COE olenoid/olenoid, , G /4 P olenoid/olenoid G / P olenoid/olenoid, , G /4 COP olenoid/olenoid olenoid operators Power consumption Current 4 V d.c. V d.c. 4 V d.c. V a.c. (W) (V) (m) (m) Ex-Protection (TEX- Category) Protection class *7) 8, IP 65 (with connector) *5) - 9, IP 65 (with connector) *5) 8, - - IIG IID - 9, - 4 IIG IID 6, IIG IID - 8,7-4 IIG IID Ex n II T4 Ex td IP65 T C Ex n II T4 Ex td IP65 T C Ex mb II T4 Ex td IP66 T C *) Ex mb II T4 Ex td IP66 T C *) Temperature mbient/ luid ( C) luid: max luid: max. 8 Electrical connection Connector DIN EN 75-8 orm *6) Connector DIN EN 75-8 orm *6) Weight Dimension Circuit diagram odel,5 46, pecial connector DIN EN 75-8 orm included in delivery, pecial connector,6 6 8 DIN EN 75-8 orm included in delivery Cable, m long, Cable, m long, , XP/DIP, Div. & lying leads 45 mm long,5 8 7 CI. I, Gr. -D CI. II/III, Gr. E-G T (6 C) *4) NE 4, 4X, 6, 6P, 7, 9-5,9-6 - XP/DIP, Div. & CI. I, Gr. -D CI. II/III, Gr. E-G T (6 C) *4) NE 4, 4X, 6, 6P, 7, lying leads 45 mm long, tandard voltages 4 V d.c., V a.c., other voltages on request. Design according to VDE 58, EN 54/58. % duty cycle. *) EG-Type-Examination-Certificate PT 6 TEX 54 X *4) C-R , pproval *5) Required connector: Type 5775 *6) Connector/cable gland not supplied, see table»ccessories«*7) IP-Protection class according to EN659 N/en /
3 66, 87 olenoid operators Power consumption 4 V d.c. V d.c. (W) (V) Current 4 V d.c. V a.c. (m) (m) 8, IIG IID -, - 4 IIG IID 8, IIG IID -, - 4 IIG IID 8, IIG IID -, - 4 IIG IID Ex-Protection (TEX- Category) Protection class *7) Ex emb II T4/T5 Ex td IP66 T C *), *) Ex emb II T4/T5 Ex td IP66 T C *), *) Ex dmb IIC T4/T6 Ex emb II T4/T6 Ex td IP66 T C *) Ex dmb IIC T4/T6 Ex emb II T4/T6 Ex td IP66 T C *) Ex dmb IIC T4/T6 Ex emb II T4/T6 Ex td IP66 T C *) Ex dmb IIC T4/T6 Ex emb II T4/T6 Ex td IP66 T C *) Temperature mbient/ luid ( C) T T T T T T T T T T T T Electrical connection tandard voltages 4 V d.c., V a.c., other voltages on request. Design according to VDE 58, EN 54/58. % duty cycle. *) EG-Type-Examination-Certificate PT 6 TEX 54 X *) EG-Type-Examination-Certificate E 98 TEX 445 X *) EG-Type-Examination-Certificate PT TEX 85 X *4) C-R , pproval *5) Required connector: Type 5775 *6) Cable gland not supplied, see table»ccessories«*7) IP-Protection class according to EN659 *) IEC Ex Certificate of Conformity ttention: The protection class for coil series 46xx and 4xx is determined by the choice of cable gland. Example: if an TEX-certified cable gland is used that has Ex d Type of protection, the solenoid will have the protection class Ex dmb; if a cable gland with Ex e Type of proteciton is used, the solenoid will have protection class Ex emb. Weight Dimension Circuit diagram odel x,5 *6), x,5 *6), /-4 NPT *6), /-4 NPT *6), x,5 *6), x,5 *6), ccessories Cable gland Protection class Ex e, Ex d (TEX), Nickel plated brass ilencer Connector Dimensions Page 8 Cable Ø aterial Protection class (TEX) odel x,5...4 mm Nickel plated brass IIGD Ex d (G/4) *) 66 (with rectifier) x,5 5,...8, mm Nickel plated brass IIGD Ex e (G/) *) 5775 /.../4 NPT 7,5...,9 mm Nickel plated brass IIGD Ex d, Ex e *) or indoors use 9/ N/en
4 66,87 Dimensions Valves 4 5 T E H P W X E H ø P T W X odel G/4 4,5 55 7,5 4,5 5,5 8, G/4 4,5 55 7,5 4,5 5,5 8, G/ 47 77,5 65, , G/ 47 77,5 65, , T Z E H P 6 W X anual override without detent anual override with detent olenoid 4 x 9 turnable E H ø P T W X Z odel G/4 96 8,5 55,5 48, ,5 8, G/ , ,5 46,5 69,5 895 N/en /
5 66, 87 4 T 4 P 5 4 E H W X E H ø P R T W X odel G/ , G/ 75 59, ,5 5 4,5 46, R T P H anual override without detent W X anual override with detent olenoid 4 x 9 turnable H ø P R T W X odel G/ , G/ ,5 5 4,5 46, / N/en
6 66,87 Dimensions R 5 T 5 P H anual override without detent anual override with detent Z olenoid 4 x 9 turnable W H ø P R T W X Z odel G/ , , G/ ,5 7 8,5 4 8, N/en /
7 66, 87 Dimensions olenoid operators ,5 4, ,5 4,5 4,5 5,5 6 X,5 8 4, X,5 9, ,5 64,5 4,5 9,5 7 x, Connector can be indexed by 4x9 Ø (with spacer tube) 9/ N/en
8 66,87 Circuit diagramm Cable gland C D C D C ø D odel x, x, /-4 NPT ,5..., only Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features«. efore using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in pneumatic systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. ystem designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. ystem designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. N/en /
97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual
More informationUM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted
U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils
More informationUM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves
U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking
More information2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
More information4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
More informationtype V46, solenoid or pneumatic operated
SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function
More informationRM/55401/M, Roundline cylinder Magnetic piston, double acting
RM/550/M, Roundline cylinder > > Ø... 00 mm > > Clean line design > > ow friction, long life seals > > Standard magnetic piston for full control system versatility Technical features Medium: Compressed
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More information2/2 & 3/2 Solenoid operated valves
2/2 & 3/2 Solenoid operated valves Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Grey cast iron Plastic resin PVDF Solenoids IP Protection class IP65 (with connector) Buschjost
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationElectrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
More informationElectro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
More informationVP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
More informationSOLENOID VALVES AND PNEUMATIC VALVES
2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the
More information3/2-way Mini Solenoid Valve
3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
More informationSingle sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
More information3 Port Solenoid Valve
ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.
More informationKA/8000/M, KA/8000, ISO cylinder (Stainless steel) Magnetic & Non-magnetic piston, double acting
K/8000/M, K/8000, ISO cylinder (Stainless steel) > > Ø 3... 00 mm > > High corrosion and acid resistance > > Ideal for applications in the food industry > > Conforms to DIN ISO 555, DIN ISO 63, VDM 56
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationsize 3 15 4200 size 4 19 6600
BE/BE ISO 99/ Valves - Compliance with ISO 99/ international standards - Full range: - - - size - Two different internal commutation system: mixed and spool, appreciated for decades thanks to their maximum
More information3/2-way pneumatic cartridge solenoid valve
3/2-way pneumatic cartridge solenoid valve Compact design with 11 mm width per station Orifices from 0.5 mm (9 bar) to 1.2 mm (1.5 bar) High durability and reliability Low power consumption, as well as
More informationFluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power
More informationSystem 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8
System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures
More information3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
More informationRPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007
Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid
More informationservo-controlled 3-WaY vacuum solenoid valves WiTH
servo-controlled 3-WaY vacuum solenoid s WiTH low absorption electric coil The 3-way vacuum solenoid s in this series feature two positions with pneumatically pilot-operated conical shutters. They can
More informationG1/4 Q8. Standard with biased position
Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,
More informationSolenoid valves 2/2-way direct-operated Type EV210A
Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral
More informationS GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR
MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,
More information2/2 and 3/2 Way Size 6 Seat Valves
2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08
More informationCartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)
Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers
More informationSPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4
SPOO & SV VAVS monostable / bistable function threaded ports -G 1/ 5/-5/3 Series 1 FATURS Reliability: steel spool & sleeve technology with long service life Robust valve design, particularly recommended
More informationSolenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
More informationzamak nitrile rubber self-extinguishing technopolymes aluminum
G 0 mm - G / Valves and solenoid valves - G/ threaded valve body with traditional Univer spool system - Version with integrated connection and esternal connection - Compact design - High flow rate - Versions
More informationControl- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
More informationzamak nitrile rubber self-extinguishing technopolymer aluminum
PS COMBOBOX valves - Valves with compact design: valve body with integrated sub-base - High flexibility: > possibility of choosing fitting dimension (--) according to users needs > manifolds from up to
More information-10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890
CL/CM UNIVERSAL Valves G1/8 - CHARACTERISTICS -10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 6,5 8,5 890 1480 die-cast zamak (G1/8), aluminium () NBR aluminium AA series/u1-u,5
More informationHigh Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override
Double 3/2 N.C. solenoid valve with manual override General The high pressure/high flow capacity solenoid valve, as not available on the market, was especially engineered by BIFFI in the early '70s for
More information5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm
More informationzamak nitrile rubber selfestinguishing technopolymer aluminum B10 24 V DC (± 10%) holding 0,32 W, pick-up 5,5 W (25 ms) IP65 button with tool
P0 0mm COMPCT valves - threaded body and for sub-base mounting - Low standard power consumption (0,W): low power consumption electropilot B0 (standard version with LED) - Quick response times - High flow
More informationSolenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.
Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 50 bar (5000 psi) and 7 L/min (60 USgpm) n Eaton rand ETON Screw-In Cartridge Valves E-VLSC-MC00-E November 009 -.
More informationSolenoid/pneumatic valves, Tiger Classic
Solenoid/pneumatic valves, Tiger Classic Electrically or pneumatically actuated valves With internal or external pilot air Sturdy and reliable Specified types in accordance with ATEX directive for potentially
More informationSOLENOID VALVES 3-4 WAY
SOLENOID VLVES - WY IE/C// CT: FP/VCR Page: 7 SHEET: / SOLENOID VLVES - - WY CV SOLENOID VLVES -WY/-POSITION /- UNF.7 5.7 The electric valve is a -way -position directional electrically controlled Slight
More information4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More information3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large
More informationISO 15407-1/2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves
BD ISO 0/ (VDM ) ISO 0 ( mm) ISO 0 ( mm) Valves BDE = solenoid valves ISO 0/ with integrated connection including V DC coils and connector BDB = solenoid valves ISO 0/ with external connection with M connector
More information3/2 Solenoid Cartridge Valve, Size 6
/ Solenoid Cartridge Valve, Size 6 Q max = l/min, p max = 5 bar Bidirectional seat-valve shut-off, direct acting Guided valve spool and poppet Two spool variants are available Available in two mounting
More information2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
More informationControl blocks for two-hand start ZSB
Key features Function This pneumatic control block for twohand start ZSB is used where a manually started operation, such as the triggering of compressed air cylinders, would otherwise involve danger for
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
More informationOn-off valves MS-EM/EE, MS series, NPT
On-off valves MS-EM/EE, MS series, NPT On-off valves MS9-EM, MS series, NPT Peripherals overview 5 3 4 aa -H- Note Additional accessories: Module connector for combinations with size MS6, MS9 or size MS12
More informationDirectional seated valves type VP 1
Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual
More informationE4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51
83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE
More informationFlow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More information3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow
1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control
More informationPlastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
More informationOverview of types. Technical data
Technical data sheet R3..xx-S.. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems For modulating water-side control of HU and heating systems ir bubble-tight
More information2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description
More informationSolenoid Valves 3- & 4-way valves for actuator control
Industry valves - solenoid valves LUCIFR Solenoid valves for actuator control Solenoid Valves 3- & 4-way valves for actuator control FLUIDTCHNIK BOHMIA s. r. o. Olomoucká 87 tel : 548 213 233-235 CZ-627
More informationLoad-sensing control block in mono and sandwich plate design
Load-sensing control block in mono and sandwich plate design RE 64276/08.2010 Replaces: 08.2008 1/64 Type M4-12 Nominal size 12 Unit series 2X Nominal pressure 350 bar (pump side) Nominal pressure 420
More information10 mm Solenoid Valves. 0,6 W Power Consumption. 10,5 mm wide. 230 l/min air-flow. Service friendly design. High quality solenoid system
10 mm Solenoid Valves 0,6 W Power Consumption 230 l/min air-flow 10,5 mm wide Service friendly design High quality solenoid system Table of Contents page 2 page 5/2 way in-line valves 3 MMD 510 301 24DC
More information0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3
Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00
More informationD634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05
D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 GENERAL SECTION PAGE MOOG SERVO- AND PROPORTIONAL CONTROL VALVES General 2 enefits and Functionality 3 General
More informationSolenoid Valve Type 3962
Solenoid Valve Type 362 x d, x em or without explosion protection, for controlling pneumatic actuators General The Type 362 Solenoid Valve ensures a high level of operational reliability for controlling
More informationMANTA Piston Distributor for Oil and Fluid Grease
MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube
More informationInrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.
Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the
More informationSpecifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.
Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical
More informationSchematic Symbols Chart (Design Hydraulic and Pneumatic circits)
Page 1 of 6 (Home) Symbols / Visit us on: Fluid Power, Automation and Motion Control for all Industries About Us Products Services Catalogs Place an Order Training & Information Contact Us Employee Access
More informationRotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch
echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data
More informationSeries P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors
European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for
More informationSolenoid valves VOFC Key features
Valve series VOFC Solenoid valves VOFC Key features General information The valves in the VOFC series are special 3/2-way and 5/2-way valves for process automation, for use within chemical and petrochemical
More informationSystem 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
More informationProportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32
www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional
More informationLine-Mounted Valves L Series
Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series
More informationSEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
More informationISO/VDMA Actuators. Engineering GREAT Solutions
ISO/VDMA Actuators Engineering GREAT Solutions 02 ISO/VDMA Actuators Contents 03 Introduction 04 ISO/VDMA Actuators 06 The ISO/VDMA Range 08 Industrial Options 10 Cleanline Options 12 IVAC innovation to
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationQPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems
The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system
More informationAIR-AIR PRESSURE MULTIPLIER (BOOSTER)
AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally
More informationSTC 3S012-020-A Series Solenoid Valves
STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,
More informationPosition Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationSICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A
s SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A Introduction The technical and descriptive information on the function, construction and selection of the new types of 3SE3 limit switches is
More informationPressure and flow control system
Pressure and flow control system RE 30030/04.09 1/32 Replaces: RE 30024/11.03 RE 30027/06.04 RE 30030/01.04 Type SYDFE1, SYDFEE, SYDFEC, SYDFEn Size 18 to 140 Component series 2X Maximum operating pressure
More informationCheck Valves & Actuated Valves
heck Valves & ctuated Valves & U Series Piston non-return valves rated 6,000 psi & 10,000 psi X Series Piston non-return valves rated 20,000 psi Pneumatic ctuators Pneumatically actuated valves Electric
More informationTyco PremiAir Pneumatic Actuators
A comprehensive range of pneumatic actuators, conforming to EN ISO 5211, providing compact, reliable and economical powered operation for all types of quarter turn valves. Features Mounting to valve either
More informationOEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
More informationMagnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
More informationCompact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationAdjustable room thermostat for heating only or cooling only systems
3 003 Room hermostat RAA30 Adjustable room thermostat for heating only or cooling only systems Room thermostat with manual O/OFF switch wo-position control witching voltage AC 24 250 V Use he RAA30 room
More information2-way flow control valve Type 2FRM 6
RE /0.0 Replaces:.0 -way flow control valve Type FRM Nominal size Series X Maximum operating pressure bar ) Maximum flow L/min ) When used in conjunction with a rectifier plate up to 0 bar H//D /97 + H//D
More informationInstruction Manual Differential Pressure Transmitter
DE28 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance